ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test Report IPC-7220 (Product Reliability Test) Report No : 04S055A0 Report Date : November 22, 2004 _______________________ _____________________ ___________________ Issue Stamp Charles Chang Manager of QA Department Charles Chang Approval Jeff Yang Test Engineer

Upload: others

Post on 07-Jul-2020

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified

ADVANTECH CO., LTD.

QA Test Report

IPC-7220

(Product Reliability Test)

Report No : 04S055A0

Report Date : November 22, 2004 _______________________ _____________________ ___________________

Issue Stamp

Charles Chang Manager of QA Department

Charles Chang Approval

Jeff Yang Test Engineer

Page 2: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

1

IPC-7220 Table of Contents Report No.04S055A0

QA Lab Reliability test

1. Test item list …………………………………………………… 2 2. Product specification entry …………………………………… 3 3. Product configuration photo………………………………….. 4 4. High temperature operation test ……………………………… 10 5. Low temperature operation test ………………………………. 14 6. High temperature & humidity storage test..…………………. 17 7. Low temperature storage test………………………………….. 21 8. Humidity test ………………………………………………….. 24 9. Temperature cycle test ………………………………………… 27

10. Thermal profile test……………………………………………. 30 11. Cold start test ………………………………………………….. 33 12. Random vibration test ……………………………………….... 36 13. Sine vibration test…………………………….………………... 42 14. Package vibration test…………………………………………. 48 15. Drop test………………………………………………………... 54

Page 3: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

2

IPC-7220 Test Item List Report No.04S055A0

QA Lab Reliability test

Num. Test item Result Remark1 High temperature operation test Passed 2 Low temperature operation test Passed 3 High temperature & humidity storage test Passed 4 Low temperature storage test Passed 5 Humidity test Passed 6 Temperature cycle test Passed 7 Thermal profile test Passed 8 Cold start test Passed 9 Random vibration test Passed

10 Sine vibration test Passed 11 Package vibration test Passed 12 Drop test Passed

Page 4: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

3

IPC-7220 Product Spec Entry Report No.04S055A0

QA Lab Reliability test IPC-7220 Desktop/Wall Mountable Chassis for ATX motherboard Num Item Specification

1 Driver Bay Two 5.25” One 3.5”

2 Cooling Two air filter (one 7 cmx 12cm and one 12 cm x12cm)

3 I/O interface 2 USB PS/2 keyboard and mouse, or PS/2 keyboard

depends on the enclosed CPU board 4 Miscellaneous Indicators---PWR,HDD,TEMP and FAN Switches---- Power and reset Rear panel--- Two D-SUB 9-pin openings 5 Dimensions (Wx Hx D) 200 x 320 x 480 mm (7.9”x 12.6”x 18.9”) 6 Weight 11.5 Kg

Page 5: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

4

IPC-7220 Product Configuration Photo Report No.04S055A0

QA Lab Reliability test Photo I:

IPC-7220 front side view

Page 6: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

5

IPC-7220 Product Configuration Photo Report No.04S055A0

QA Lab Reliability test Photo II:

IPC-7220 front side view (open front case)

Page 7: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

6

IPC-7220 Product Configuration Photo Report No.04S055A0

QA Lab Reliability test Photo III:

IPC-7220 rear side view

Page 8: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

7

IPC-7220 Product Configuration Photo Report No.04S055A0

QA Lab Reliability test Photo IV:

IPC-7220 over look

Page 9: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

8

IPC-7220 Product Configuration Photo Report No.04S055A0

QA Lab Reliability test Photo V:

IPC-7220 structure photo I

Page 10: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

9

IPC-7220 Product Configuration Photo Report No.04S055A0

QA Lab Reliability test Photo VI:

IPC-7220 structure photo II

Page 11: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

10

IPC-7220 High Temp. Operation Test Report No.04S055A0

QA Lab Reliability test Test Date : September 22, 2004 ~ September 23, 2004 Test Site : Advantech QA Environment Lab Performed By : Jeff Yang Purpose : The DVT test Test Standard : Reference IEC68-2-2 Testing procedures Test Bb : Dry Heat Test Test Condition : 1. Test Temperature : 45℃ 2. Test Times : 24Hrs 3. Test Software : Running HCT 9.5 in Win2000 4. Test Environment Curve :

Temp℃

45℃

25℃

time Hrs 0:0 1:00 25:00 26:00

Page 12: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

11

IPC-7220 High Temp. Operation Test Report No.04S055A0

QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber K.SON. INS. TECH CORP. Model : THS-D7S +–150-LN2 Date of Calibration : 04/09/2004 Sample Configuration & Quantity Under Test : Using one IPC-7220 with the following options installed :

1. M/B: AIMB-742 Rev. A1 2. CPU : Intel Pentium 4 3.2GHz 3. RAM : Apacer DDR400 512MB 4. HDD : Seagate ST340015A 5. FDD : TEAC FD-235HF 6. CD-ROM : Aopen CD-952E/AKV 7. Power supply : FSP300-60PVN 300W 8. Heatsink fan : CoolJag Everflow R127015BU Performance Criteria : Electronic function check:

1.All system functions must be checked with appropriate testing programs and should pass the inspection.

2.Running Win2000 for OS, the system should not have degradation in its performance.

Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.

Page 13: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

12

IPC-7220 High Temp. Operation Test Report No.04S055A0

QA Lab Reliability test Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The IPC-7220 meets high temperature operation test.

Page 14: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

13

IPC-7220 High Temp. Operation Test Report No.04S055A0

QA Lab Reliability test Photo :

IPC-7220 high temperature operation test

Page 15: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

14

IPC-7220 Low Temp. Operation Test Report No.04S055A0

QA Lab Reliability test Test Date : September 27, 2004 ~ September 28, 2004 Test Site : Advantech QA Environment Lab Performed By : Jeff Yang Purpose : The DVT test Test Standard : Reference IEC68-2-1 Testing procedures Test Ab : Cold Test Test Condition :

1. Test Temperature : -5℃ 2. Test Times : 24Hrs 3. Test Software : Running HCT 9.5 in Win2000

4. Test Environment Curve :

Temp℃

25℃

-5℃

Time Hrs

0:0 1:30 25:30 27:00

Page 16: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

15

IPC-7220 Low Temp. Operation Test Report No.04S055A0

QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber K.SON. INS. TECH CORP. Model : THS-D7S +–150-LN2 Date of Calibration : 04/09/2004 Sample Configuration & Quantity Under Test : Using one IPC-7220 with the following options installed :

1. M/B: AIMB-742 Rev. A1 2. CPU : Intel Pentium 4 3.2GHz 3. RAM : Apacer DDR400 512MB 4. HDD : Seagate ST340015A 5. FDD : TEAC FD-235HF 6. CD-ROM : Aopen CD-952E/AKV 7. Power supply : FSP300-60PVN 300W 8. Heatsink fan : CoolJag Everflow R127015BU Performance Criteria : Electronic function check:

1.All system functions must be checked with appropriate testing programs and should pass the inspection.

2.Running Win2000 for OS, the system should not have degradation in its performance.

Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.

Page 17: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

16

IPC-7220 Low Temp. Operation Test Report No.04S055A0

QA Lab Reliability test Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The IPC-7220 meets low temperature operation test.

Page 18: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

17

IPC-7220 High Temp. &Hum. Storage Test Report No.04S055A0

QA Lab Reliability test Test Date : October 29, 2004 ~ November 01, 2004 Test Site : Advantech QA Environment Lab Performed By : Jeff Yang Purpose : The DVT test Test Standard : Reference IEC68-2-56 Testing procedures Test Cb : Damp Heat Steady State Test Test Condition :

1. Test Temperature : 60℃ 2. Test Humidity : 95% 3. Test Times : 48Hrs 4. Test Software : Running HCT 9.5 in Win2000

5. Test Environment Curve :

Humidity %

Temp℃

95%

60℃

25℃

50%

Time Hrs 0:00 0:52 48:52 49:44

Page 19: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

18

IPC-7220 High Temp. &Hum. Storage Test Report No.04S055A0

QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber K.SON. INS. TECH CORP. Model : THS-D7S +–150-LN2 Date of Calibration : 04/09/2004 Sample Configuration & Quantity Under Test : Using one IPC-7220 with the following options installed :

1. M/B: AIMB-742 Rev. A1 2. CPU : Intel Pentium 4 3.2GHz 3. RAM : Apacer DDR400 512MB 4. HDD : Seagate ST340015A 5. FDD : TEAC FD-235HF 6. CD-ROM : Aopen CD-952E/AKV 7. Power supply : FSP300-60PVN 300W 8. Heatsink fan : CoolJag Everflow R127015BU Performance Criteria : Electronic function check:

1.All system functions must be checked with appropriate testing programs and should pass the inspection.

2.Running Win2000 for OS, the system should not have degradation in its performance.

Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.

Page 20: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

19

IPC-7220 High Temp. &Hum. Storage Test Report No.04S055A0

QA Lab Reliability test Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The IPC-7220 meets high temperature & humidity storage test.

Page 21: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

20

IPC-7220 High Temp. &Hum. Storage Test Report No.04S055A0

QA Lab Reliability test Photo :

IPC-7220 high temperature & humidity storage test

Page 22: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

21

IPC-7220 Low Temp. Storage Test Report No.04S055A0

QA Lab Reliability test Test Date : October 01, 2004 ~ October 04, 2004 Test Site : Advantech QA Environment Lab Performed By : Jeff Yang Purpose : The DVT test Test Standard : Reference IEC68-2-1 Testing procedures Test Ab : Cold Test Test Condition : 1. Test Temperature : -40℃ 2. Test Times : 48Hrs

3. Test Software : Running HCT 9.5 in Win2000 4. Test Environment Curve :

Temp℃

25℃

-40℃

Time Hrs

0:0 1:37 49:37 51:14

Page 23: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

22

IPC-7220 Low Temp. Storage Test Report No.04S055A0

QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber K.SON. INS. TECH CORP. Model : THS-D7S +–150-LN2 Date of Calibration : 04/09/2004 Sample Configuration & Quantity Under Test : Using one IPC-7220 with the following options installed :

1. M/B: AIMB-742 Rev. A1 2. CPU : Intel Pentium 4 3.2GHz 3. RAM : Apacer DDR400 512MB 4. HDD : Seagate ST340015A 5. FDD : TEAC FD-235HF 6. CD-ROM : Aopen CD-952E/AKV 7. Power supply : FSP300-60PVN 300W 8. Heatsink fan : CoolJag Everflow R127015BU Performance Criteria : Electronic function check:

1.All system functions must be checked with appropriate testing programs and should pass the inspection.

2.Running Win2000 for OS, the system should not have degradation in its performance.

Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.

Page 24: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

23

IPC-7220 Low Temp. Storage Test Report No.04S055A0

QA Lab Reliability test Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The IPC-7220 meets low temperature storage test.

Page 25: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

24

IPC-7220 Humidity Test Report no. 04S055A0

QA Lab Reliability test Test Date : September 27, 2004 ~ September 30, 2004 Test Site : Advantech QA Environment Lab Performed By : Jeff Yang Purpose : The DVT test. Test Standard : Reference IEC68-2-3 Testing procedures Test Ca : Damp Heat steady state Test Test Condition :

1. Test Temperature : 40℃ 2. Test Humidity : 95% 3. Test Times : 48Hrs 4. Test Software : Running HCT 9.5 in Win2000

5. Test Environment Curve :

Humidity %

Temp℃

95%

40℃

25℃

50%

Time Hrs 0:00 0:45 48:45 49:30

Page 26: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

25

IPC-7220 Humidity Test Report no. 04S055A0

QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber K.SON. INS. TECH CORP. Model : THS-D7S +–150-LN2 Date of Calibration : 04/09/2004 Sample Configuration & Quantity Under Test : Using one IPC-7220 with the following options installed :

1. M/B: AIMB-742 Rev. A1 2. CPU : Intel Pentium 4 3.2GHz 3. RAM : Apacer DDR400 512MB 4. HDD : Seagate ST340015A 5. FDD : TEAC FD-235HF 6. CD-ROM : Aopen CD-952E/AKV 7. Power supply : FSP300-60PVN 300W 8. Heatsink fan : CoolJag Everflow R127015BU Performance Criteria : Electronic function check:

1.All system functions must be checked with appropriate testing programs and should pass the inspection.

2.Running Win2000 for OS, the system should not have degradation in its performance.

Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.

Page 27: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

26

IPC-7220 Humidity Test Report no. 04S055A0

QA Lab Reliability test Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The IPC-7220 meets humidity test.

Page 28: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

27

IPC-7220 Temperature Cycle Test Report No.04S055A0

QA Lab Reliability test Test Date : September 24 , 2004 ~ September 26, 2004 Test Site : Advantech QA Environment Lab Performed By : Jeff Yang

Purpose : The DVT test. Test Standard : Reference IEC68-2-14 Testing procedures

Test N: Change of temperature Test

Test Condition : 1. Test High Temperature: 40℃

2. Test Low Temperature: 0℃ 3. Test dwell time: 2Hrs 4. Temperature slope: heating 30 minutes, cooling 1 hour 5. Test cycle: 10 cycles 6 Test Software : Running HCT 9.5 in Win2000 7. Test Environment Curve:

Total 10 Cycle …….. 0 0:12 2:12 3:12 5:12 5:30 55:00

Temp. 40℃ Temp.25℃ Temp. 0℃ Time Hrs

Page 29: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

28

IPC-7220 Temperature Cycle Test Report No.04S055A0

QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber K.SON. INS. TECH CORP. Model : THS-D7S +–150-LN2 Date of Calibration : 04/09/2004 Sample Configuration & Quantity Under Test : Using one IPC-7220 with the following options installed :

1. M/B: AIMB-742 Rev. A1 2. CPU : Intel Pentium 4 3.2GHz 3. RAM : Apacer DDR400 512MB 4. HDD : Seagate ST340015A 5. FDD : TEAC FD-235HF 6. CD-ROM : Aopen CD-952E/AKV 7. Power supply : FSP300-60PVN 300W 8. Heatsink fan : CoolJag Everflow R127015BU Performance Criteria : Electronic function check:

1.All system functions must be checked with appropriate testing programs and should pass the inspection.

2.Running Win2000 for OS, the system should not have degradation in its performance.

Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.

Page 30: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

29

IPC-7220 Temperature Cycle Test Report No.04S055A0

QA Lab Reliability test Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion :

Passed. The IPC-7220 meets temperature cycle test.

Page 31: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

30

IPC-7220 Thermal Profile Test Report No.04S055A0

QA Lab Reliability test Test Date : November 09 ,2004 ~ November 10, 2004 Test Site : Advantech QA Environment Lab Performed By : Jeff Yang Purpose : The DVT test Test Standard : Reference IEC68-2-2 Testing procedures Test Bb : Dry Heat Test Test Condition : 1. Test Temperature : 25℃/40℃/45℃ 2. Test Times : Each temperature 6 Hrs 3. Test Program: Running HCT 9.5 in Win2000 Test Equipment : Programmable Temperature & Humidity Chamber K.SON. INS. Tech. Corp.. Model : THS-D4L+-100 Date of Calibration : 06/01/2004 DATA LOGGER YOKOGAWA CO. LTD. Model : uP-1800 S/N : 47XS0063 Date of Calibration : 08/09/2004

Page 32: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

31

IPC-7220 Thermal Profile Test Report No.04S055A0

QA Lab Reliability test Sample Configuration & Quantity Under Test : Using one IPC-7220 with the following options installed :

1. M/B: AIMB-742 Rev. A1 2. CPU : Intel Pentium 4 3.2GHz 3. RAM : Apacer DDR400 512MB 4. HDD : Seagate ST340015A 5. FDD : TEAC FD-235HF 6. CD-ROM : Aopen CD-952E/AKV 7. Power supply : FSP300-60PVN 300W 8. Heatsink fan : CoolJag Everflow R127015BU Performance Criteria : Electronic function check:

1.All system functions must be checked with appropriate testing programs and should pass the inspection.

2.Running Win2000 for OS, the system should not have degradation in its performance.

Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.

Page 33: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

32

IPC-7220 Thermal Profile Test Report No.04S055A0

QA Lab Reliability test Test Data :

Num Parts List 25℃ 40℃ 45℃

1. CPU heatsink temperature 48.2 64.3 68.4 2. Northbridge heatsink temperature 39.5 52.7 57.3 3. U16 51.6 65.8 70.4 4. Lan chip (U14) 47.8 62.7 67.0 5. Southbridge case temperature (U30) 57.7 73.2 77.5 6. (U7) 32.4 46.5 50.7 7. (U4) 41.2 55.1 58.9 8. HDD- 33.5 47.8 51.6 9. System air temperature

( below power supply) 42.7 59.9 63.7

10. System air temperature (near PCI slot) 32.1 45.6 49.6 11. System air temperature ( back the HDD) 32.0 46.1 50.8

Test Result :

The system specification of thermal profile is 40 degree C. The Pentium4 3.2GHz CPU thermal specification is 70 degree C. There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The IPC-7220 meets thermal profile test.

Page 34: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

33

IPC-7220 Cold Start Test ReportNo.04S055A0

QA Lab Reliability test Test Date : November 27, 2004 ~ November 28, 2004 Test Site : Advantech QA Environment Lab Performed By : Jeff Yang Purpose : The DVT test. Test Condition : 1. Test Temperature : -10℃ 2. Test Times : 8Hrs Step: A. System power off 4 hours. B. System power on , then 2 minutes later, system power off. C. After 10 minutes, system power on again. D. Two minutes later, system power off again. E. Recycle step C& D for 20 times. 3. Number of test : 20 times 4. Test Software : Win2000

5. Test Environment Curve:

1 2 18 19 20 Times iiii 0:0 1:45 5:4510min 9:45 11:00 12:45

Temp℃

25℃

Power ON

-10℃

Power OFF

Time Hrs

Page 35: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

34

IPC-7220 Cold Start Test ReportNo.04S055A0

QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber K.SON. INS. TECH CORP. Model : THS-D7S +–150-LN2 Date of Calibration : 04/09/2004 Sample Configuration & Quantity Under Test : Using one IPC-7220 with the following options installed :

1. M/B: AIMB-742 Rev. A1 2. CPU : Intel Pentium 4 3.2GHz 3. RAM : Apacer DDR400 512MB 4. HDD : Seagate ST340015A 5. FDD : TEAC FD-235HF 6. CD-ROM : Aopen CD-952E/AKV 7. Power supply : FSP300-60PVN 300W 8. Heatsink fan : CoolJag Everflow R127015BU Performance Criteria : Electronic function check:

1.All system functions must be checked with appropriate testing programs and should pass the inspection.

2.Running Win2000 for OS, the system should not have degradation in its performance.

Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.

Page 36: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

35

IPC-7220 Cold Start Test ReportNo.04S055A0

QA Lab Reliability test Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The IPC-7220 meets cold start test.

Page 37: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

36

IPC-7220 Random Vibration Test Report No.04S055A0

QA Lab Reliability test Test Date : September 08, 2004 Test Site : Advantech QA Environment Lab Performed By : Jeff Yang Test Standard : Reference IEC68-2-64 Testing procedures Test Fh : Vibration boardband random test Purpose : The DVT test. Test Condition : 1. Test PSD : 0.002G²/Hz , 1 Grms 2. System condition : Operation mode

3. Test Program: Running soft- MPEG file in Win2000 4. Test Frequency : 5-500Hz 5. Test Axis : X,Y and Z axis 6. Test Time : 1hr per each axis 7. Test curve:

Acceleration 1 Grms

PSD 0.002g²/Hz

5Hz 500Hz

Page 38: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

37

IPC-7220 Random Vibration Test Report No.04S055A0

QA Lab Reliability test Test Equipment : Vibration Simulator System KING DESIGN Co. LTD. Model : 9363EM-600F2K-40N120 S / N : UC107142493 Date of Calibration : 09/20/2004 Sample Configuration & Quantity Under Test : Using one IPC-7220 with the following options installed :

1. M/B: AIMB-742 Rev. A1 2. CPU : Intel Pentium 4 3.2GHz 3. RAM : Apacer DDR400 512MB 4. HDD : Seagate ST340015A 5. FDD : TEAC FD-235HF 6. CD-ROM : Aopen CD-952E/AKV 7. Power supply : FSP300-60PVN 300W 8. Heatsink fan : CoolJag Everflow R127015BU Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate testing programs and should pass the inspection.

2. Running Win2000 for OS, the system should not have degradation in its performance.

Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.

3. All gaps on the surface are appropriately. 4. The assembling/disassembling of the system enclosure or mechanical parts must be smooth ,and no deformed parts should be found.

Page 39: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

38

IPC-7220 Random Vibration Test Report No.04S055A0

QA Lab Reliability test Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The IPC-7220 meets random operation vibration test.

Page 40: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

39

IPC-7220 Random Vibration Test Report No.04S055A0

QA Lab Reliability test Photo I:

IPC-7220 random vibration test for X-axis

Page 41: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

40

IPC-7220 Random Vibration Test Report No.04S055A0

QA Lab Reliability test Photo II:

IPC-7220 random vibration test for Y-axis

Page 42: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

41

IPC-7220 Random Vibration Test Report No.04S055A0

QA Lab Reliability test Photo III:

IPC-7220 random vibration test for Z-axis

Page 43: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

42

IPC-7220 Sine Vibration Test ReportNo.04S055A0

QA Lab Reliability test Test Date : September 09, 2004 Test Site : Advantech QA Environment Lab Performed By : Jeff Yang Purpose : The DVT test. Test Standard : Reference IEC68-2-6 Testing procedures Test Fc : Vibration Sinusoidal Test Test Condition : 1. Test Acceleration : 2G 2. System condition : Non-operation 3. Test Frequency : 5-500Hz 4. Test Velocity : 1 Octave / min 5. Test Axis : X,Y,Z axis 6. Test Time : 1 hour pre axis 7. Test Vibration Curve :

Acceleration

2G

Displacement

4.4mm

5Hz 15Hz 500Hz

Page 44: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

43

IPC-7220 Sine Vibration Test ReportNo.04S055A0

QA Lab Reliability test Test Equipment : Vibration Simulator System KING DESIGN Co. LTD. Model : 9363EM-600F2K-40N120 S / N : UC107142493 Date of Calibration : 09/20/2004 Sample Configuration & Quantity Under Test : Using one IPC-7220 with the following options installed :

1. M/B: AIMB-742 Rev. A1 2. CPU : Intel Pentium 4 3.2GHz 3. RAM : Apacer DDR400 512MB 4. HDD : Seagate ST340015A 5. FDD : TEAC FD-235HF 6. CD-ROM : Aopen CD-952E/AKV 7. Power supply : FSP300-60PVN 300W 8. Heatsink fan : CoolJag Everflow R127015BU Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate testing programs and should pass the inspection.

2. Running Win2000 for OS, the system should not have any incurable physical damage.

Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.

3. All gaps on the surface are appropriately. 4. The assembling/disassembling of the system enclosure or mechanical parts must be smooth ,and no deformed parts should be found.

Page 45: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

44

IPC-7220 Sine Vibration Test ReportNo.04S055A0

QA Lab Reliability test Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The IPC-7220 meets sine non-operation vibration test.

Page 46: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

45

IPC-7220 Sine Vibration Test ReportNo.04S055A0

QA Lab Reliability test Photo I:

IPC-7220 sine vibration test for X-axis

Page 47: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

46

IPC-7220 Sine Vibration Test ReportNo.04S055A0

QA Lab Reliability test Photo II:

IPC-7220 sine vibration test for Y-axis

Page 48: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

47

IPC-7220 Sine Vibration Test ReportNo.04S055A0

QA Lab Reliability test Photo III:

IPC-7220 sine vibration test for Z-axis

Page 49: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

48

IPC-7220 Package Vibration Test ReportNo.04S055A0

QA Lab Reliability test Test Date : November 10, 2004 Test Site : Advantech QA Environment Lab Performed By : Jeff Yang Test purpose : The DVT test Test Standard : Reference IEC68-2-64 Testing procedures Test Fh : Vibration boardband random test Test Condition : 1. Test PSD : 0.016G²/Hz, 2.16Grms 2. Test Frequency : 5-500Hz 3. Test Axis : X,Y,Z three axes 4. Test Time : 1 hour each axis 5. Test Curve :

Acceleration 2.16Grms -6db/oct

PSD 0.016g²/Hz

0.0016g²/Hz

5Hz 200Hz 500Hz

Page 50: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

49

IPC-7220 Package Vibration Test ReportNo.04S055A0

QA Lab Reliability test Test Equipment : Vibration Simulator System KING DESIGN Co. LTD. Model : 9363EM-600F2K-40N120 S / N : UC107142493 Date of Calibration : 09/20/2004 Sample Configuration & Quantity Under Test : Using one IPC-7220 with the following options installed :

1. M/B: AIMB-742 Rev. A1 2. CPU : Intel Pentium 4 3.2GHz 3. RAM : Apacer DDR400 512MB 4. HDD : Seagate ST340015A 5. FDD : TEAC FD-235HF 6. CD-ROM : Aopen CD-952E/AKV 7. Power supply : FSP300-60PVN 300W 8. Heatsink fan : CoolJag Everflow R127015BU Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate testing programs and should pass the inspection.

2. Running Win2000 for OS, the system should not have degradation in its performance.

Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.

3. All gaps on the surface are appropriately. 4. The assembling/disassembling of the system enclosure or mechanical parts must be smooth ,and no deformed parts should be found.

Page 51: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

50

IPC-7220 Package Vibration Test ReportNo.04S055A0

QA Lab Reliability test Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The IPC-7220 meets package vibration test.

Page 52: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

51

IPC-7220 Package Vibration Test ReportNo.04S055A0

QA Lab Reliability test Photo I:

IPC-7220 package vibration test for X-axis

Page 53: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

52

IPC-7220 Package Vibration Test ReportNo.04S055A0

QA Lab Reliability test Photo II:

IPC-7220 package vibration test for Y-axis

Page 54: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

53

IPC-7220 Package Vibration Test ReportNo.04S055A0

QA Lab Reliability test Photo III:

IPC-7220 package vibration test for Z-axis

Page 55: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

54

IPC-7220 Drop Test Report No.04S055A0

QA Lab Reliability test

Test Date : September 14, 2004 Test Site : Advantech QA Environment Lab Performed By : Jeff Yang Purpose : The DVT test. Test Standard : Reference Federal Standard 101 Method 5007 Testing procedure B

Test Ea : Drop Test Test Condition :

1. Test Phase : One corner Three edges Six faces

2. Test Height : 76cm 3. Package Weight : 19.0Kg 4. Package Dimension : 58.0cm×32.4cm×45.6cm 5. Test Drawing :

Topside Rear Side Left Side Right Side Bottom Side Mid Edge Front Side Short Edge Long Edge Damage Corner

Page 56: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

55

IPC-7220 Drop Test Report No.04S055A0

QA Lab Reliability test

Test Equipment : Drop Tester machine YOSHIDA SEIKI Co. LTD. Model: DT-100B Sample Configuration & Quantity Under Test : Using one IPC-7220 with the following options installed :

1. M/B: AIMB-742 Rev. A1 2. CPU : Intel Pentium 4 3.2GHz 3. RAM : Apacer DDR400 512MB 4. HDD : Seagate ST340015A 5. FDD : TEAC FD-235HF 6. CD-ROM : Aopen CD-952E/AKV 7. Power supply : FSP300-60PVN 300W 8. Heatsink fan : CoolJag Everflow R127015BU Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate testing programs and should pass the inspection.

2. Running Win2000 for OS, the system should not have degradation in its performance.

Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.

3. All gaps on the surface are appropriately. 4. The assembling/disassembling of the system enclosure or mechanical parts must be smooth ,and no deformed parts should be found.

Page 57: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

56

IPC-7220 Drop Test Report No.04S055A0

QA Lab Reliability test

Test Data:

Side Acceleration Front 43.0G Rear 42.9G Right 43.0G Left 42.3G Top 40.1G Bottom 40.3G

Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The IPC-7220 meets drop test.

Page 58: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

57

IPC-7220 Drop Test Report No.04S055A0

QA Lab Reliability test Photo I:

IPC-7220 drop test for one corner

Page 59: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

58

IPC-7220 Drop Test Report No.04S055A0

QA Lab Reliability test Photo II:

IPC-7220 drop test for three edges

Page 60: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

59

IPC-7220 Drop Test Report No.04S055A0

QA Lab Reliability test Photo III:

IPC-7220 drop test for six faces

Page 61: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

60

IPC-7220 Drop Test Report No.04S055A0

QA Lab Reliability test Photo IV:

IPC-7220 drop test for structure photo

Page 62: QA Test Report - Advantechadvdownload.advantech.com › productfile › Downloadfile › 1...ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test

61

IPC-7220 Drop Test Report No.04S055A0

QA Lab Reliability test Photo V:

PE form