6
EN Extremely robust and sealed Crossflow plate heat exchanger Type PWT

Upload: vuongtruc

Post on 30-Aug-2018

226 views

Category:

Documents


0 download

TRANSCRIPT

EN

E N E R G Y R E C O V E R Y

PWT EN

0216

Extremely robust and sealedCrossflow plate heat exchanger Type PWT

PWTDimensions

Dimensions

Type A[mm]

B[mm]

C[mm] Efficiency1)

PWT 200 203 265 individual up to 60%

PWT 300 303 405 individual up to 60%

PWT 390 390 531 individual up to 60%

Dimensions

Typ A[mm]

B[mm]

C[mm] Efficiency1)

PWT 400 400 563 individual up to 60%

PWT 500 500 677 individual up to 60%

PWT 600 600 819 individual up to 65%

PWT 700 700 960 individual up to 65%

PWT 800 800 1101 individual up to 70%

PWT 1000 1000 1384 individual up to 70%

PWT 1200 1200 1667 individual up to 70%

1) Efficiency depends on plate distance and air quantity.Technical changes possible.

1) Efficiency depends on plate distance and air quantity.Technical changes possible.

DATAPWT

A

A

C

B

A

C

AB

Klingenburg GmbH • Boystrasse 115 • D-45968 Gladbeck / GermanyPhone: +49-(0) 20 43-96 36 0 • Fax: +49-(0) 20 43-7 23 62 • E-mail: [email protected]

www.klingenburg.de

Rotary Heat Exchanger - Execution as aluminum,

epoxy, enthalpy or sorption rotor

- High Temperature Rotor made of stainless steel

Crossflow- Plate Heat Exchanger

- Aluminium, PET, epoxy and stainless steel versions available

Counterflow- Plate Heat Exchanger - Aluminium, PET and epoxy

versions available- Highest efficiency

Humidifier CERTO

- Hygienic humidification

- Adiabatic cooling

Outside air

Exhaust air

Supply air

Extract air

Outside air

Exhaust airSupply air

Extract air

PWT 400 - 1200 PWT 200 - 390

Shapes and sizesPWTAluminium Crossflow Plate Heat Exchanger

Plate heat exchangers are the preferred option in ventila-tion systems where any ‘circulation’ of air is undesirable. In other words, the incoming and outgoing airstreams are completely isolated and no moisture or odours can be transferred. Thus, plate heat exchangers are examples of recuperative energy recovery systems.

Application

Room ventilation systems Industrial ventilaton systems Total separation of supply and waste air Heat-recovery in winter Cooling-recovery in summer

Application

Room ventilation systems Controlled apartment ventilation Total separation of supply and waste air Heat-recovery in winter Cooling-recovery in summer

Crossflow arrangement incorporating two PWTs

Two heat-exchanger groups can be arranged in a cross-/counterflow pattern to increase efficiency.

Modular construction

Any required group length and edge lenghts up to 3000 mm can be supplied, thanks to modular structure.

PWT 10

PWT 30

PWT 20

PWT 40

PWT 25

PWT 60

Configuration options

High tightness and strength thanks to double folding of the intake-flow edges (fivefold material thickness)

High tightness and strength thanks to folding of the intake-flow edges (threefold material thickness).

Plate distance: corrugated inserts – plate distances from 8 up to 13 mm

The heat exchangers consist of corrosion resistant aluminium foil

Different plate distances and any re-quired group length can be supplied

All housings are equipped with condensate drain-off. Plate structure:

embossed plates – plate distances from 5.5 up to 14 mm

Droplet separator

400

500

600

700

800

1000

1200

1000 2000 3000Air volume [m3/h]

Edge

leng

th [m

m]

Edge

leng

th [m

m]

Diagram for selection of a suitable plate heat exchanger

5000 10000 20000

400

500

600

700

800

1000

1200

200

300

390

0 500 1000Air volume [m3/h]

Diagram for selection of a suitable plate heat exchanger

50

55

60

65

70

75

80

35 40 45 50 55 60 65

0,6 0,81,0

1,2

1,4

Mass flow ratio msupply/mextract

Single exchange efficiency Fsingle [%]

Fto

t [%

]

Diagram for determination of efficiencywith two PWTs in a cross-/counterflow pattern

1500 2000 2500 3000

200

300

390

Shapes

Outside air

Outside air

Outside air

Outside air

Exhaust air

Exhaust air

Exhaust airSupply air

Supply airProcess supply air

Hall supply airExtract air

Extra

ct air

Extra

ct air

Outside air

Exhaust air

Supply air

Extract air

Outside air

Exhaust airSupply air

Extract air

PWT 400 - 1200 PWT 200 - 390

Shapes and sizesPWTAluminium Crossflow Plate Heat Exchanger

Plate heat exchangers are the preferred option in ventila-tion systems where any ‘circulation’ of air is undesirable. In other words, the incoming and outgoing airstreams are completely isolated and no moisture or odours can be transferred. Thus, plate heat exchangers are examples of recuperative energy recovery systems.

Application

Room ventilation systems Industrial ventilaton systems Total separation of supply and waste air Heat-recovery in winter Cooling-recovery in summer

Application

Room ventilation systems Controlled apartment ventilation Total separation of supply and waste air Heat-recovery in winter Cooling-recovery in summer

Crossflow arrangement incorporating two PWTs

Two heat-exchanger groups can be arranged in a cross-/counterflow pattern to increase efficiency.

Modular construction

Any required group length and edge lenghts up to 3000 mm can be supplied, thanks to modular structure.

PWT 10

PWT 30

PWT 20

PWT 40

PWT 25

PWT 60

Configuration options

High tightness and strength thanks to double folding of the intake-flow edges (fivefold material thickness)

High tightness and strength thanks to folding of the intake-flow edges (threefold material thickness).

Plate distance: corrugated inserts – plate distances from 8 up to 13 mm

The heat exchangers consist of corrosion resistant aluminium foil

Different plate distances and any re-quired group length can be supplied

All housings are equipped with condensate drain-off. Plate structure:

embossed plates – plate distances from 5.5 up to 14 mm

Droplet separator

400

500

600

700

800

1000

1200

1000 2000 3000Air volume [m3/h]

Edge

leng

th [m

m]

Edge

leng

th [m

m]

Diagram for selection of a suitable plate heat exchanger

5000 10000 20000

400

500

600

700

800

1000

1200

200

300

390

0 500 1000Air volume [m3/h]

Diagram for selection of a suitable plate heat exchanger

50

55

60

65

70

75

80

35 40 45 50 55 60 65

0,6 0,81,0

1,2

1,4

Mass flow ratio msupply/mextract

Single exchange efficiency Fsingle [%]

Fto

t [%

]

Diagram for determination of efficiencywith two PWTs in a cross-/counterflow pattern

1500 2000 2500 3000

200

300

390

Shapes

Outside air

Outside air

Outside air

Outside air

Exhaust air

Exhaust air

Exhaust airSupply air

Supply airProcess supply air

Hall supply airExtract air

Extra

ct air

Extra

ct air

Outside air

Exhaust air

Supply air

Extract air

Outside air

Exhaust airSupply air

Extract air

PWT 400 - 1200 PWT 200 - 390

Shapes and sizesPWTAluminium Crossflow Plate Heat Exchanger

Plate heat exchangers are the preferred option in ventila-tion systems where any ‘circulation’ of air is undesirable. In other words, the incoming and outgoing airstreams are completely isolated and no moisture or odours can be transferred. Thus, plate heat exchangers are examples of recuperative energy recovery systems.

Application

Room ventilation systems Industrial ventilaton systems Total separation of supply and waste air Heat-recovery in winter Cooling-recovery in summer

Application

Room ventilation systems Controlled apartment ventilation Total separation of supply and waste air Heat-recovery in winter Cooling-recovery in summer

Crossflow arrangement incorporating two PWTs

Two heat-exchanger groups can be arranged in a cross-/counterflow pattern to increase efficiency.

Modular construction

Any required group length and edge lenghts up to 3000 mm can be supplied, thanks to modular structure.

PWT 10

PWT 30

PWT 20

PWT 40

PWT 25

PWT 60

Configuration options

High tightness and strength thanks to double folding of the intake-flow edges (fivefold material thickness)

High tightness and strength thanks to folding of the intake-flow edges (threefold material thickness).

Plate distance: corrugated inserts – plate distances from 8 up to 13 mm

The heat exchangers consist of corrosion resistant aluminium foil

Different plate distances and any re-quired group length can be supplied

All housings are equipped with condensate drain-off. Plate structure:

embossed plates – plate distances from 5.5 up to 14 mm

Droplet separator

400

500

600

700

800

1000

1200

1000 2000 3000Air volume [m3/h]

Edge

leng

th [m

m]

Edge

leng

th [m

m]

Diagram for selection of a suitable plate heat exchanger

5000 10000 20000

400

500

600

700

800

1000

1200

200

300

390

0 500 1000Air volume [m3/h]

Diagram for selection of a suitable plate heat exchanger

50

55

60

65

70

75

80

35 40 45 50 55 60 65

0,6 0,81,0

1,2

1,4

Mass flow ratio msupply/mextract

Single exchange efficiency Fsingle [%]

Fto

t [%

]

Diagram for determination of efficiencywith two PWTs in a cross-/counterflow pattern

1500 2000 2500 3000

200

300

390

Shapes

Outside air

Outside air

Outside air

Outside air

Exhaust air

Exhaust air

Exhaust airSupply air

Supply airProcess supply air

Hall supply airExtract air

Extra

ct air

Extra

ct air

EN

E N E R G Y R E C O V E R Y

PWT EN

0216

Extremely robust and sealedCrossflow plate heat exchanger Type PWT

PWTDimensions

Dimensions

Type A[mm]

B[mm]

C[mm] Efficiency1)

PWT 200 203 265 individual up to 60%

PWT 300 303 405 individual up to 60%

PWT 390 390 531 individual up to 60%

Dimensions

Typ A[mm]

B[mm]

C[mm] Efficiency1)

PWT 400 400 563 individual up to 60%

PWT 500 500 677 individual up to 60%

PWT 600 600 819 individual up to 65%

PWT 700 700 960 individual up to 65%

PWT 800 800 1101 individual up to 70%

PWT 1000 1000 1384 individual up to 70%

PWT 1200 1200 1667 individual up to 70%

1) Efficiency depends on plate distance and air quantity.Technical changes possible.

1) Efficiency depends on plate distance and air quantity.Technical changes possible.

DATAPWT

A

A

C

B

A

C

AB

Klingenburg GmbH • Boystrasse 115 • D-45968 Gladbeck / GermanyPhone: +49-(0) 20 43-96 36 0 • Fax: +49-(0) 20 43-7 23 62 • E-mail: [email protected]

www.klingenburg.de

Rotary Heat Exchanger - Execution as aluminum,

epoxy, enthalpy or sorption rotor

- High Temperature Rotor made of stainless steel

Crossflow- Plate Heat Exchanger

- Aluminium, PET, epoxy and stainless steel versions available

Counterflow- Plate Heat Exchanger - Aluminium, PET and epoxy

versions available- Highest efficiency

Humidifier CERTO

- Hygienic humidification

- Adiabatic cooling

EN

E N E R G Y R E C O V E R Y

PWT EN

0216

Extremely robust and sealedCrossflow plate heat exchanger Type PWT

PWTDimensions

Dimensions

Type A[mm]

B[mm]

C[mm] Efficiency1)

PWT 200 203 265 individual up to 60%

PWT 300 303 405 individual up to 60%

PWT 390 390 531 individual up to 60%

Dimensions

Typ A[mm]

B[mm]

C[mm] Efficiency1)

PWT 400 400 563 individual up to 60%

PWT 500 500 677 individual up to 60%

PWT 600 600 819 individual up to 65%

PWT 700 700 960 individual up to 65%

PWT 800 800 1101 individual up to 70%

PWT 1000 1000 1384 individual up to 70%

PWT 1200 1200 1667 individual up to 70%

1) Efficiency depends on plate distance and air quantity.Technical changes possible.

1) Efficiency depends on plate distance and air quantity.Technical changes possible.

DATAPWT

A

A

C

B

A

C

AB

Klingenburg GmbH • Boystrasse 115 • D-45968 Gladbeck / GermanyPhone: +49-(0) 20 43-96 36 0 • Fax: +49-(0) 20 43-7 23 62 • E-mail: [email protected]

www.klingenburg.de

Rotary Heat Exchanger - Execution as aluminum,

epoxy, enthalpy or sorption rotor

- High Temperature Rotor made of stainless steel

Crossflow- Plate Heat Exchanger

- Aluminium, PET, epoxy and stainless steel versions available

Counterflow- Plate Heat Exchanger - Aluminium, PET and epoxy

versions available- Highest efficiency

Humidifier CERTO

- Hygienic humidification

- Adiabatic cooling