pure flush-out brochure

4

Upload: jung-hao-ching

Post on 07-Mar-2016

215 views

Category:

Documents


0 download

DESCRIPTION

PURE Flush-out Brochure

TRANSCRIPT

Page 1: PURE Flush-out Brochure
Page 2: PURE Flush-out Brochure

Indoor Air Quality During Construction

Construction Site Flush-Out Services

Rapidly eliminate construction-generated airborne particulates, VOCs and odor.

Interior Construction Produces: Dust Particles, VOCs, Bio Aerosols...

PURE Air Purifier Installation( Classified as a Class II Medical Device by the FDA )

Results - End users can inhabit the space sooner, without negative impacts to comfort and health.

WHAT WE DO ?

Large Office Spaces :

During Construction: Continuously flush the air through PURE’s patented a mixture of carbon, zeolite, phosphorus saturated filters + the patented EMF HEPA filtration machines dramatically reduces VOCs and captures and kills 100% of air borne particles Bio-aerosols.

At Construction End and Furniture is Moved in:

Increase the amount of Carbon/Zeolite air treatmentOvernight High Ozone Shock TreatmentDeep cleaning and Application of PURE DEOAddition of Tea Tree Oil in AC Units

Hotel Rooms and Residential:

48 hours of Air Flush Out with PURE patented filtration units.Carbon/Zeolite air treatmentOvernight High Ozone Shock TreatmentDeep cleaning and Application of PURE DEOAddition of Tea Tree Oil in AC Units.

Hazardous Ultra Fine Dust Particles – can float in the air for weeks

Cutting & grinding of wood, plywood, laminates, plastics. plaster, insulation , stone, tile…

Sanding & drilling of drywall, wood, metal, plastic, cement, spray painting and lacquer finishes.

Ultra-Fine Particles 0.01 to 5.0 Microns floating in the air for weeks.

VOCs...volatile organic compounds ... chemical odors

Formaldehyde – plywood, insulation, gypsum board, furniture, cabinets.

General VOCs – glues, sealants, paints, thinners, carpets, wall coverings, laminates, plastics, furniture, insulation, chairs, tables etc.

VOC Gases – Easily spread through the space and difficult to contain. Off gassing can continue for months.

Bio Aerosols

Molds, fungi, bacteria, virus can easily grow in humid conditions.

Problem : Dust Particles, VOCs, Bio Aerosols...

short term - asthma attacks, allergies, itchy eyes, runny nose, skin rash, headaches, nausea…. uncomfortable, unhappy staff

long term – linked to heart disease, stroke, respiratory problem.

Particles

Particles

2 Weeks

2 Weeks

Fit Out Construction / 4 Weeks

Fit Out Construction / 4 Weeks

Walls // Ceilings // Floors

Walls // Ceilings // Floors

Major Finishes

Major Finishes

Carpet Furniture

Carpet Furniture

2 Weeks

2 Weeks

VOC

VOC

Occ

up

ancy

Occ

up

ancy

TYPICAL CONSTRUCTION AIR QUALITY

USING PURE AIR SCRUBBING TECHNOLOGY

Legal Limits

Legal Limits

Legal Limits

Legal Limits

Page 3: PURE Flush-out Brochure

TVOC ppm CO2 ppm CO ppm °C %RH 0.3µm 0.5µm 1.0µm 2.5µm 5.0µm 10.0µm

Before Flush Out 1.53 425 1.60 24 65 4304000 339000 60500 22000 2700 800

After Flush Out 1.67 681 1.65 22 45 186335 18577 3661 558 39 8

TVOC ppm CO2 ppm CO ppm °C %RH 0.3µm 0.5µm 1.0µm 2.5µm 5.0µm 10.0µm

Before Flush Out 3.48 916 2.05 22 61 1960404 227452 7666 2439 539 167

After Flush Out 1.67 681 1.65 22 45 38581 1603 369 178 73 24

TVOC ppm CO2 ppm CO ppm °C %RH 0.3µm 0.5µm 1.0µm 2.5µm 5.0µm 10.0µm

Before Flush Out 16.6 533 2.5 25.0 64.8 7980945 2872045 1001095 34585 54431 4435

After Flush Out 3.7 495 1.9 25.7 64.5 725650 40140 15200 6510 1020 140

Success Stories

Texas Instruments -Taipei Office

Nestle -Taipei Office

Westin Hotel - Taipei -

Before During During Complete

Before During During Complete

Before During During Complete

Taiwan Indoor Air Quality Law to soon take effect… Example of Test Requirement

Texas Instrument Office

285 Rooms Fully RenovatedResults - No Customer Complaints

Page 4: PURE Flush-out Brochure

The PURE Process results have been confirmed by third-party scientists, and PURE Rooms are regularly tested by trained technicians to ensure our high standards are met.

We worry about the air quality so you don’t have to.Price is usually less than 1% of the cost of construction ; Call 8862-2772-2321

PURE Air Filtration Options Long Term Solutions for Healthy Spaces

PURE has different size air filtration units to meet any need to create excellence in healthy indoor environments

Floor StandingFDA Listed Class ll Medical Device

Ceiling Mount System

600 CFM Might Mite Air Scrubber units

In-Line Modular System

100 CFM to 20,000+ CFM

All PURE Air Purification Systems are patented and contain:

• 3-stage filtration delivering better than HEPA quality filtration at significantly lower Energy Consumption

- Pre-filtering- Carbon Zeolite filters for VOC removal- 100% sealed, certified, and Patented DFS Filtering (Disinfecting Filtration System), exceeds HEPA standards

• Patented Kill Zone destroys all Virus, Bacteria, Mold, Fungi

• 100% filtration at low energy costs

• Easy to Service and Maintain

100 to 250 CFM Pure Air Delivery

1. Electronic control panel with remote control

2.100% Pure Air Delivery

3. DFS – Revolutionary Germ Kill Zone

4. 100% Sealed and Individually Certified HEPA Filter

5. Filter Efficiency Monitor

6. Dual intake multi speed blower

7. Activated Carbon-Zeolite & Pre-filters

8. 360 degree air intake

- 150 to 300 CFM PURE Air Delivers

- Optional duct kits for multi room delivery of PURE Air

- Covers up to 2000 sq feet

- Carbon Zeolite Filtration for VOC capture

- 100% particle removal through the 3 stage filtration including the patented DFS technology

- Remote control

- Multi-speed fans

- Portable and heavy duty

- Flexible ductwork to reach any area

- Carbon filtration to remove VOCs

- 3 stage filtration including HEPA Filters

- 2000 CFM Portable units for Flush out

- Carbon Zeolite Filtration for VOC capture

- 100% particle removal through the 3 stage filtration including the patented DFS technology

- In-Line Units for permanent installation in ductwork

- 2,000 cfm expandable to 20,000 cfm and above

- Ultra low energy operation costs

-Ease of maintenance