pulse velocity test

12
ULTRASONIC PULSE VELOCITY TEST (NDT on Hardened concrete) BY BY: AKSHAY R MANOHAR 1 sem Mtech(Construction Technology) CIVIL ENGINEERING DEPT. NMAMIT-NITTE.

Upload: sjmitnow-nmamit-nitte

Post on 29-Nov-2014

80 views

Category:

Engineering


2 download

DESCRIPTION

Ultrasonic measurements are used in structural engineering to determine material properties, detect defects. and assess deterioration. Ultrasonic wave propagation characteristics that can be used for these purposes are:velocity. attenuation, frequency, and energy. In assessing material deterioration. a reference property value, such as ultrasonic pulse velocity(UPY). is determined using laboratory specimens, Field measurements are compared with the reference property value to assess the condition of the material.

TRANSCRIPT

Page 1: Pulse velocity test

ULTRASONIC PULSE VELOCITY TEST(NDT on Hardened concrete)

BY BY:

AKSHAY R MANOHAR1 sem Mtech(Construction Technology) CIVIL ENGINEERING DEPT.

NMAMIT-NITTE.

Page 2: Pulse velocity test
Page 3: Pulse velocity test
Page 4: Pulse velocity test
Page 5: Pulse velocity test
Page 6: Pulse velocity test

ULTRASONIC PULSE VELOCITY TEST

• This test is done to assess the quality of concrete by ultrasonic pulse velocity method as per IS: 13311 (Part 1) – 1992.

Page 7: Pulse velocity test

PRINCIPLE OF TEST

The method consists of measuring the time of travel of an ultrasonic pulse passing through the concrete being tested.

Comparatively higher velocity is obtained when concrete quality is good in terms of density, uniformity, homogeneity etc.

Page 8: Pulse velocity test

Concrete quality accordingly to pulse velocity.

Page 9: Pulse velocity test

Significance and Use

• Uniformity and relative quality of concrete .

• To indicate the presence of voids and cracks, and to evaluate the effectiveness of crack repairs.

• When used to monitor changes in condition over time, test locations are to be marked on the structure to ensure that tests are repeated at the same positions.

Page 10: Pulse velocity test

• The degree of saturation of the concrete affects the pulse velocity

• The pulse velocity is independent of the dimensions of the test object provided reflected waves from boundaries

Page 11: Pulse velocity test

REFERENCE

• Ultrasonic Pulse Velocity in Concrete Using Direct and Indirect Transmission. by Ismail Ozgur Yaman, Gokhan Inei, Nazli Yesiller, and Haluk M.

• CONCRETE TECHNOLOGY – A text book- ML Gambhir.

Page 12: Pulse velocity test