eaton/@mem/...2 wiring accessories and single phase distribution pg00400018u – march 2012 powering...

164
Wiring accessories and single phase distribution Smart solutions for electrical distribution in residential and commercial applications MEM series wiring accessories xComfort wireless controls Memera consumer units & devices LSC plug-in lighting system

Upload: others

Post on 02-Feb-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

  • Wiring accessories and single phase distribution

    Smart solutions for electrical distribution in residential and commercial applications

    • MEM� series wiring accessories• xComfort wireless controls• Memera consumer units & devices• LSC plug-in lighting system

  • 2 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    Powering business worldwide

    Discover Eaton – a leader in the power management field

    Since 1911, when our company began trading as a small truck parts supplier, Eaton® Corporation has come a long way. Today, as a diversified power management company, Eaton has sales of $11.9 billion USD (FY 2009), employs 70,000 people and has customers in more than 150 countries. Everyday, we help companies across the world to manage power, and do more, while consuming less energy.

    Eaton’s innovative products, solutions and technologies are designed to help customers to manage power and conserve resources while working more productively, safely and sustainably. Our integrated and diversified business strategy ensures that we remain at the forefront of our industry, decade after decade.

    Aerospace

    A leading global supplier to commercial and military aviation and aerospace industries. An extensive technology portfolio includes hydraulic systems, fuel systems, motion control systems, propulsion sub-systems, cockpit controls and displays and fluid health monitoring systems. Our products improve fuel economy, aircraft performance, reliability and safety.

    Truck

    A leader in the design, manufacture and marketing of complete line of drivetrain systems and components for medium- and heavy-duty commercial vehicles. Under the “Roadranger” brand, Eaton also markets lubricants, safety products and service tools. Eaton’s hybrid power systems have earned the company recognition as a global leader in alternative power for commercial vehicles.

    Electrical

    A global leader in electrical control, power distribution, uninterruptible power supply and industrial automation products and services. Our products provide customer-driven PowerChain Management® solutions to serve the power system needs of the industrial, institutional, government, utility, commercial, residential, IT, mission critical and OEM markets worldwide.

    Aerospace Truck

    HPL0200-2011_Imageseiten_neu.indd 1 07.12.2010 15:18:08 Uhr

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 3

    Powering businessmore sustainably

    Sustainability – smaller footprint in the world

    The principle of sustainability means meeting the current needs of our own society without compromising the needs or options of future generations. It is a principle, which forms the very core of our design and production philosophy and guides all our activities across the world. Our commitment to reducing our own ecological footprint covers a wide range of green technologies, products and services that help our customers utilise electrical power more efficiently, while improving environmental performance.

    Eaton has been recognised throughout the world for its uncompromising business ethics. For example, it was listed as one of the ‘World’s Most Ethical Companies’ on the Ethisphere Institute’s annual list for three consecutive years (2007, 2008 and 2009).

    Learn more about Eaton Green Solutions at www.eaton.com/greensolutions

    When you see this symbol, you know the solution represents an Eaton bench-mark for environmental performance.

    Electrical Automotive Hydraulics

    Automotive

    A supplier of critical components that reduce emissions and fuel consumption and improve stability and performance of cars, light trucks and commercial vehicles. Principal products include engine valves and valve train components, transmission and engine controls, supercharger, locking and limited slip differentials, cylinder heads, fluid conveyance components, body mouldings and spoilers.

    Hydraulics

    A worldwide leader in reliable, high-efficiency hydraulic systems and components for use in mobile and industrial applications. Markets include agriculture, construction, mining, forestry, utility, material handling, earth moving, truck and bus, machine tools, moulding, primary metals, automotive, power generation, port machinery and entertainment.

    HPL0200-2011_Imageseiten_neu.indd 2 07.12.2010 15:18:08 Uhr

  • 4 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    Buildings Information Technology

    • Data centers• Telecommunication• Networks• Computer rooms

    • World’s most efficient line of UPSs to reduce footprint and save energy

    • Reliable power systems with inherent redundancy to improve availability

    • Power metering and monitoring to diagnose problems and lower costs

    • Local service and support for quick response

    Powering electrical systems worldwide

    • Residential• Healthcare• Education• Commercial offices• Retail• Public sector• Airports

    • Electrical distribution solutions for safe and efficient power delivery

    • Power quality systems for uptime and reliability

    • Power metering and monitoring to add intelligence and save costs

    • Industrial control products for HVAC applications

    HPL0200-2011_Imageseiten_neu.indd 3 07.12.2010 15:18:09 Uhr

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 5

    Industrial & Machinery Energy & Utilities

    • Manufacturing• Agriculture• Construction• Mining and metals• Processing:

    • Petrochemicals • Pharmaceuticals

    • Pulp and paper• Material handling

    • Electrical distribution equipment to deliver power throughout the enterprise

    • Control & automation and power quality equipment for process control

    • Power metering and monitoring to manage energy costs and uptime

    • Power and motion control products to optimize productivity, reliability, safety and operator comfort

    • Renewable energy:

    • Solar

    • Wind

    • Hydropower• Traditional energy:

    • Oil

    • Gas• Smart grid• Water and waste water

    • Electrical balance of system and turnkey services for residential, utility and commercial solar installations

    • Power distribution equipment, control components and system installations services

    • Network power grid technology for intelligent data, lower costs and crew / public safety

    Public and private sectors

    Buildings, Information Technology, Industrial & Machinery, Energy & UtilitiesWe provide reliable, efficient and safe power management.

    HPL0200-2011_Imageseiten_neu.indd 4 07.12.2010 15:18:10 Uhr

  • Complete coverage of the market – worldwide in all standards

    Local market leader with global competence

    Eaton’s product series are distinguished by their strong presence in all regions of the world. In markets that adhere to IEC standards, Eaton’s Moeller line is very well established, and in the world of UL/CSA, Eaton is a key player, for example with its Cutler-Hammer line. Now all customers are benefiting from first-rate engineering and the combined know-how in research and development – no matter which standards they use.

    In electrical engineering, it was less continents and regions but rather standards that drew boundaries. Historically grown in the U.S. market, Eaton focused on product series according to UL/CSA standards. Consequently, Eaton’s Electrical Sector was always strongly geared towards the markets in North and South America, the Middle East, Benelux as well as the United Kingdom.

    Moeller series products from Eaton are the customers’ first choice in markets adhering to IEC standards for innovative switchgear and control circuit devices, control, drive and operating systems as well as sophisticated visualization and communication.

    HPL0200-2011_Imageseiten_neu.indd 5 07.12.2010 15:18:12 Uhr

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 7

    Index 157

    12 Technical data 125

    Wiring accessories and single phase distribution

    5 COPA clip-on plate 61

    3 PREMERA mix 45

    2 PREMERA white moulded 33

    1 Product overview 9

    Contents

    4 PREMERA proof 59

    6 COPA fi x 73

    7 XTRA surface metalclad 81

    8 CIRCA ceiling range 87

    9 LSC plug-in lighting system 93

    10 xComfort system overview 97

    11 MEMERA consumer units 107

  • 8 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 9

    Product overview 1

    Eaton’s comprehensive range of wiring accessories

    and single phase distribution solutions have been

    developed to meet today’s challenging electrical

    applications in residential and light commercial projects

    and applications. Through a proven competency in

    electrical distribution, Eaton delivers an innovative and

    fl exible approach to aid compliance with the regulatory

    requirements associated with modern buildings.

    1.1 PREMERA WIRING ACCESSORIES PREMERA white moulded .......................................................................................................................................................... 10 PREMERA mix ........................................................................................................................................................................10–11

    PREMERA proof .......................................................................................................................................................................... 13

    COPA clip-on plate ....................................................................................................................................................................... 11

    COPA fi x ...................................................................................................................................................................................... 12

    XTRA surface metalclad .............................................................................................................................................................. 13

    Wall mounted range options...................................................................................................................................................14–17

    1.2 CIRCA CEILING RANGE ............................................................................................................................................................. 181.3 LSC PLUG-IN LIGHTING SYSTEM ............................................................................................................................................ 191.4 MEMERA CONSUMER UNITS AND DEVICES ......................................................................................................................... 20 Moulded consumer units ............................................................................................................................................................. 21 Metalclad consumer units ........................................................................................................................................................... 22

    Consumer unit solutions .............................................................................................................................................................. 28

    Switch and protection devices ..................................................................................................................................................... 29

    Control and switching devices ..................................................................................................................................................... 30

    1.5 RF BUILDING AUTOMATION AND CONTROLS ....................................................................................................................... 32

  • 10 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    Product overviewPREMERA wiring accessories1.1

    PREMERA white moulded range

    PREMERA offers a new consistent range of white accessories combining good aesthetics and high quality material

    High quality sturdy, thermoset material

    Optional screw cap covers to add the fi nishing touches

    Inherent protection against MRSA

    White or grey covers available enabling compliance to DDA (Disability Discrimination Act)/Part M requirements

    New aesthetic design throughout the full range

    9mm depth front plate provides adequate wiring space in the back box

    Throughout the range, all the bases have consistent clear markings

    High quality thermoplastic base material

    2 earth terminals on all double pole sockets

    Large tunnel terminals for good wiring access

    Combination screw-head on all terminal screws enabling quicker, safer termination

    PREMERA mix modular range

    White or grey cover plate option to enable compliance with DDA/Part M requirements

    Laser marking of legends for longevity and high quality lettering

    Plate options from 1 gang to 24 gang, in either ‘screw fi xed’ version or ‘clip on’ version

    Large stylish rockers for easy operation

    Quick, easy front loading modules –simply push and ‘click’in

    Optional screw cap covers to add the fi nishing touches

    Broad rocker option to meet latest DDA/Building regulations

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 11

    Product overviewPREMERA wiring accessories 1.1

    High quality thermoplastic material on bases

    1–4 gang mounting plates come complete with integral earth strap avoiding the need to order separate grid

    Large terminals for good wiring access

    Top facing terminals for easy access and quicker installation

    Quick, easy removal of modules via clip release

    Wiring diagram shown on each module

    Bottom terminals angled in slightly to aid access to screws from the top

    Module plates up to 12 gang in urea material and 24 gang in COPA ‘clip-on’ or ‘screw fi x’ versions

    Totally modular system incorporating;

    Power switches, standard & broad rocker options•

    Power sockets in various worldwide styles•

    Power indicators, fuses units, cable outlets•

    Dimmer modules•

    Communication modules including RJ45 Cat 6, isolated co-axial/• satellite outlets, standard telephone outlets, including RJ11

    xComfort radio frequency switch modules•

    6–24 gang mounting plates comes with all the frames/• mounts/screws required – just order the modules you need

    6–24 gang mounting plates have individual removable banks • for ease of installation and future changes. Banks removed via quarter turn fasteners offering quick release/fi tting

    PREMERA mix combinations

    Various socket options to offer a wide choice of worldwide applications;

    Standard 13A • sockets BS1363

    Non standard 13A•

    5 and 15 Amp round pin•

    US standard 15A • 3 pin sockets

    European Schuko sockets•

    Key switched socket • with power indicator

    Unique key switch with • integral neon indicator

  • 12 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    Product overviewPREMERA wiring accessories1.1

    COPA clip-on plate range

    Eaton’s COPA range is strengthened with the introduction of the PREMERA mix range.

    Includes new modular plate options up to 24 gang•

    Plates available in decorative plastic fi nishes • and high quality metal fi nishes

    Plates can be affi xed by either clip-on or screw on • option depending on the clients’ requirements

    The following key aspects need to be considered to comply with Part M – Building Regulations.

    Eaton’s clip-on plate accessory range provides a very easy way to meet the requirements under the Electrical Installations section for switches, outlets and controls.

    Design considerations – Part M:4.28 Controls that contrast visually with their surroundings are more convenient for visually impaired people, as are light switches that are activated by a large push pad.

    Eaton’s solutions:

    A range of 10 standard colours/fi nishes will ensure a suitable contrast is maintained between wall and plate switch/socket.

    It is recommended that a 30-point difference in the light refl ective value (LRV) be achieved between the two surfaces. The LRV scale runs from 0, which is a perfectly absorbing surface that could be assumed to be totally black, up to 100, which is a perfectly refl ective surface that could be considered to be the perfect white.

    With COPA, the switch/socket plate colour can be left to the last minute due to its simple clip-on facility. This allows for late confi rmation or unknown wall colour. It also avoids any damage to the front plate during wall preparation/painting.

    Choice of 10 contrasting colour/fi nish plates.•

    Final colour of plate can be left to the last minute and • clipped on once the wall surround colour is known.

    Design considerations – Part M:4.28 Controls that contrast visually with their surroundings are more convenient for visually impaired people, as are light switches that are activated by a large push pad.

    Eaton’s solutions:

    A comprehensive range of broad rocker switches with contrasting coverplates is available including:

    1 and 2 gang large rocker 2 way switches•

    Intermediate switches•

    Double pole switches•

    Push switches•

    Light Refl ective Value (LRV) plate guide

    Plate fi nish Approx. LRV

    BM BLACK MATT 26GY GREY 39BL BLUE METALLIC 59SB SATIN BRONZE 62SV SILVER METALLIC 65SS STAINLESS STEEL 70GL GOLD METALLIC 77HP HIGHLY POLISHED 82PB POLISHED BRASS 83WH WHITE 89

    Design considerations – Part M:4.29 It is also an advantage if individual switches on panels and on multiple socket outlets are well separated, or in the form of large touch plates, to avoid the inadvertent selection of an adjacent control by visually impaired people and individuals with limited dexterity.

    Eaton’s solutions:

    Eaton offers a comprehensive range of sockets with outboard (separated) rockers. Coloured plates can be selected to provide suitable visual contrast.

    In Summary:

    Eaton’s clip-on plate accessory range offers simple solutions;

    Broad rocker range throughout the range fi nishes.•

    Outboard rockers on sockets.•

    Contrasting clip-on plates for all products.•

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 13

    Product overviewPREMERA wiring accessories 1.1

    COPA fi x range

    The COPA style of plate is being extended to now offer an alternative to the ‘Clip on’ plate by offering the same plate profi le with it’s stylish good looks but with a fi xed plate.

    COPA fi x:

    offers a solution in situations where it is more desirable to have screw fi xed plates. It is • appreciated not every application is suitable for clip-on plates and in situations such as prisons, schools, public places, it offers the consultant a choice dependant on the clients requirements

    will also benefi t from the PREMERA mix range of modular components • up to 24 gang size offering many modular solutions

    will be available in the two most popular fi nishes, Stainless Steel and Highly Polished•

    COPA – clip-on plate version

    COPA fi x – fi xed plate version

    PREMERA proof

    Provides an extensive range of combinations • by utilising the 1 and 2 gang IP66 enclosures making a wide variety of combinations

    A new range of weatherproof accessories • offering protection up to IP66

    STEP 1Fit interior electrically safe and can be tested to IET Regulations at this stage.

    STEP 2Determine the colour of the wall then decorate.

    STEP 3Choose fi nish to meet 30 point LRV criteria.

    XTRA surface metalclad range

    A subtle change has been made to the front plate style to • bring the range more in line with the latest plate style offered in the new look MEM� series of wiring accessories

    Will also benefi t from the PREMERA mix range of modular • components up to 24 gang size offering many modular solutions

    Easy installation – COPA (Clip-on Plate Accessory) range

  • 14 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    Product overviewPREMERA wiring accessories1.1

    Wall mounted range

    Description PREMERA COPA COPA COPA COPA COPA COPA fi x COPA fi x XTRA range c/w interior black decorative metal stainless highly surface cover interior plates1) plates 2) steel polished metal

    10A switches – 1 way10A 1G 1 way P011 C011WH C011 C011B CP0111) CM0112) – – –10A 2G 1 way P012 C012WH C012 C012B CP0121) CM0122) – – –10A 3G 1 way P013 C013WH C013 C013B CP0131) CM0132) – – –10A 4G 1 way P014 C014WH C014 C014B CP0141) CM0142) – – –10A 1G 1 way bell push P015 C015WH C015 C015B CP0151) CM0152) B015SS B015HP –10A 1G 1 way light symbol push P015L C015LWH – – CP015L1) CM015L2) – – –10A 1G 1 way push P015P – – – – – – – –10A 1G intermediate P017 C017WH C017 C017B CP0111) CM0112) B017SS B017HP X017MG10A switches – 2 way10A 1G 2 way P021 C021WH C021 C021B CP0111) CM0112) B021SS B021HP X021MG10A 1G 2 way push P021P – – – – – – – –10A 2G 2 way P022 C022WH C022 C022B CP0121) CM0122) B022SS B022HP X022MG10A 3G 2 way P023 C023WH C023 C023B CP0131) CM0132) B023SS B023HP X023MG10A 4G 2 way P024 C024WH C024 C024B CP0141) CM0142) – – –10A 6G 2 way P026 C026WH C026 C026B CP0261) CM0262) – – –10A fan isolator10A 3-pole fan isolator + fan symbol P048 C048WH C048 C048B CP0481) CM0482) B048SS B048HP X048MG10A 3-pole isolator P049 C049WH – – CP0491) CM0492) – – X049MG10A broad rocker switches10A 2G 2 way half broad P032 C032WH C032 C032B CP0131) CM0132) – – –10A 1G 2 way broad P041 C041WH C041 C041B CP0131) CM0132) – – X041MG10A 1G 2 way broad push P041P – – – – – – – –10A 2G 2 way broad P042 – – – – – – – –10A 1G 1 way broad bell push P045 C045WH C045 C045B CP0451) CM0452) – – –10A 1G 1 way broad push P045P – – – – – – – –10A 1G intermediate broad P047 C047WH C047 C047B CP0131) CM0132) – – –10A 1G DP broad + neon P043N – – – – – – – –16A hotel switch16A hotel switch P450 – – – – – – – –Dimmers250W 1G 2 way push tungsten P9131 C9131WH C9131 – CP3511) CM3512) – – –250W 2G 2 way push tungsten P9132 C9132WH C9132 – CP91321) CM91322) – – –400W 1G 2 way push tungsten P9141 C9141WH C9141 – CP3511) CM3512) – – –400W 2G 2 way push tungsten P9142 – – – – – – – –1000W 1G 2 way push tungsten (2G plate size) P9111 – C9111 – CP91111) CM91112) – – –1–10V 1G 1 way analogue P9101 – – – – – – – –500W 1G 1 way tungsten non-european P9551 C9551WH C9551 – CP3511) CM3512) – – –500W 2G 1 way tungsten non-european P9552 C9552WH C9552 – CP91321) CM91322) – – –1000W 1G 1 way tungsten non-european P9511 C9511WH C9511 – CP3511) CM3512) – – –60–500W fan controller non-european P9751 C9751WH C9751 – CP3511) CM3512) – – –13A switched sockets – single pole13A 1G P611 – – – – – – – –13A 2G P612 – – – – – – – –13A switched sockets – double pole13A 1G DP 2E terminals P621 C621WH C621 C621B CP6211) CM6212) B621SS B621HP X621MG13A 1G DP 2E terminals – grey cover P621GY – C621 – CP621GY – – – –13A 1G DP 2E terminals + neon P621N C621NWH C621N C621NB CP621N1) CM621N2) B621NSS B621NHP X621NMG13A 1G DP 2E terminals – red cover P621RED – – – – – – – –13A 1G DP 2E terminals + red rockers P621RR – – – – – B621RRSS – X621RRMG13A 2G DP 2E terminals P622 C622WH C622 C622B CP6221) CM6222) B622SS B622HP X622MG13A 2G DP 2E terminals + neon P622N C622NWH C622N C622NB CP622N1) CM622N2) B622NSS B622NHP X622NMG13A 2G DP 2E terminals + red rockers P622RR – – – – – B622RRSS – X622RRMG

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 15

    Product overviewPREMERA wiring accessories 1.1

    Wall mounted range (contd)

    Description PREMERA COPA COPA COPA COPA COPA COPA fi x COPA fi x XTRA range c/w interior black decorative metal stainless highly surface cover interior plates1) plates 2) steel polished metal

    13A switched sockets – double pole, outboard rockers13A 2G DP 2E terminals P632 C632WH C632 C632B CP6321) CM6322) B632SS – X632MG13A 2G DP 2E terminals – grey cover P632GY – C632 – CP632GY – – – –13A 2G DP 2E terminals – red cover P632RED – – – – – – – –13A 2G DP 2E terminals – red rockers P632RR – – – – – – – X632RRMG13A 2G DP 2E terminals + neon P632N – – – – – – – –13A switched sockets – double pole, non-standard13A 1G DP 2E terminals P651 C651WH C651 C651B CP6211) CM6212) B651SS – X651MG13A 1G DP 2E terminals + neon P651N – – – – – – – X651NMG13A 2G DP 2E terminals – outboard rockers P652 C652WH C652 C652B CP6321) CM6322) B652SS – X652MG13A 2G DP 2E terminals – outboard red rockers P652RR – – – – – – – –13A switched sockets – double pole, outboard rockers, clean earth13A 2G with 2E terminals P672 – – – – – – – –13A RCD socket13A 2G RCD 30mA – passive P686 – – – – – – – X686MG13A unswitched sockets13A 1G P111 C111WH C111 C111B CP1111) CM1112) B111SS – X111MG13A 2G P112 C112WH C112 C112B CP1121) CM1122) B112SS – X112MG5A sockets5A 1G – C305WH C305 C305B CP3051) CM3052) B305SS – X305MG16A sockets16A 2 pin universal – C461WH C461 C461B CP0111) CM0112) – –15A switched sockets15A 1G P415 C415WH C415 C415B CP4151) CM4152) B415SS – X415MGShaver supply unitDual voltage 230V/115V AC P370 C370WH C370 C370B CP3701) CM3702) B370SS – –13A connection units – double pole switched with optional cable outlets13A connection unit P221 C221WH C221 C221B CP2211) CM2212) B221SS B221HP X221MG13A connection unit – grey cover P221GY – C221 – CP2211) – – – –13A connection unit ‘boiler’ P221BO – – – – – – – –13A connection unit ‘central heating’ P221CH – – – – – – – –13A connection unit ‘cooker hood’ P221CKH – – – – – – – –13A connection unit ‘dishwasher’ P221DW – – – – – – – –13A connection unit ‘extract fan’ P221EF – – – – – – – –13A connection unit ‘refrigerator’ P221R – – – CP221RWH – – – –13A connection unit + red rocker P221RR – – – – – – – X221RRMG13A connection unit ‘washing machine’ P221WM – – – CP221WMWH – – – –13A connection unit fi tted with 3A fuse P223 – – – – – – – –13A connection units – double pole switched + neon with optional cable outlets13A connection unit P221N C221NWH C221N C221NB CP221N1) CM221N2) B221NSS B221NHP X221NMG13A connection unit – grey cover P221NGY – C221N – CP221NGY – – – –13A connection unit ‘refrigerator’ P221NR – – – CP221NRWH – – – –13A connection unit + red rocker P221NRR – – – – – – – X221NRRMG13A connection unit ‘water heater’ P221NWH – – – – – – – –13A connection unit ‘washing machine’ P221NWM – – – CP221NWMWH – – – –13A connection unit ‘boiler’ P221NBO – – – – – – – –13A connection unit ‘dishwasher’ P221NDW – – – – – – – –13A connection unit ‘fridge freezer’ P221NFF – – – – – – – –13A connection unit ‘hob’ P221NHO – – – – – – – –13A connection unit ‘tumble dryer’ P221NTD – – – – – – – –

  • 16 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    Product overviewPREMERA wiring accessories1.1

    Wall mounted range (contd)

    Description PREMERA COPA COPA COPA COPA COPA COPA fi x COPA fi x XTRA range c/w interior black decorative metal stainless highly surface cover interior plates1) plates 2) steel polished metal

    13A connection units – unswitched with optional cable outlets13A connection unit P220 C220WH C220 C220B CP2201) CM2202) B220SS – X220MG13A connection unit + red fuse drawer P220RR – – – – – – – X220RRMG13A connection unit fi tted with 3A fuse P224 – – – – – – – –13A connection units – unswitched + neon with optional cable outlets13A connection unit P220N C220NWH C220N C220NB CP220N1) CM220N2) B220NSS – X220NMG13A connection unit fi tted with 3A fuse P223N – – – – – – – –20A double pole switches with optional cable outlet20A switch P401 C401WH C401 C401B CP4011) CM4012) B401SS – X401MG20A switch marked ‘water heater’ P403 C403WH – – – CM4032) – – –20A double pole switches + neon with optional cable outlets20A switch P401N C401NWH C401N C401NB CP401N1) CM401N2) B401NSS – X401NMG20A switch marked ‘water heater’ P403N C403NWH – – CP403N1) CM403N2) B403NSS – –20A switch marked ‘air conditioner’ P404N – – – – – B404NSS – –45A double pole switches – cooker control units45A DP cooker control unit P425 C425WH C425 C425B CP4251) CM4252) – – –45A DP cooker control unit + neon P425N C425NWH C425N C425NB CP425N1) CM425N2) B425NSS – –50A double pole switches – 2 gang plate size50A DP switch P421 – – – – – – – X421MG50A DP switch + neon P421N C421NWH C421N C421NB CP421N1) CM421N2) B421NSS – X421NMG50A DP switch marked ‘cooker’ P423 – – – – – – – –50A DP switch + neon marked ‘cooker’ P423N C423NWH – – CP423N1) CM423N2) – – –50A DP switch + neon marked ‘air conditioner’ P424N C424NWH – – CP424N1) CM424N2) – – –50A double pole switches – 1 gang plate size50A DP switch + neon P422N C422NWH C422N C422NB CP422N1) CM422N2) B422NSS – –50A DP switch + neon – grey cover P422NGY – C422N – CP422NGY – – – –50A DP switch + neon marked ‘cooker’ P426N C426NWH – – – – B426NSS – –50A DP switch + neon marked ‘air conditioner’ P427N – – – – – – – –Cable/cooker outlet/cable outlet adaptor plate20A fl ex outlet plate P210 – – – – – – – –Cable outlet adaptor plate for 20A switch/3A fused connection unit P212 C212 – – – – – – –45A DP cable outlet with terminal block P345 – – – – – – – –Phone outlets1G telephone outlet master P360 C360WH C360 C360B CP3601) CM3602) B360SS – X360MG1G telephone outlet secondary P361 C361WH C361 C361B CP3601) CM3602) B361SS – X361MG1G american telephone outlet RJ11 P362 C362WH C362 C362B CP3601) CM3602) – – –Data outlets1G RJ45 CAT 6 outlet interior – C363WH C363 C363B CP3601) CM3602) – – –Communication outlets1G TV co-axial P351 C351WH C351 C351B CP3511) CM3512) B351SS – –1G TV co-axial dual clamp P351D – – – – – – – –2G TV co-axial outlet P352 C352WH C352 C352B CP3521) CM3522) – – –1G TV/FM isolated co-axial P353 C353WH C353 C353B CP3511) CM3512) – – –2G TV/FM diplexer co-axial P354 C354WH C354 C354B CP3521) CM3522) B354SS – –1G satellite P355 C355WH C355 C355B CP3511) CM3512) B355SS – –2G TV/satellite P356 C356WH C356 C356B CP3521) CM3522) B356SS – –2G TV/radio P357 – – – – – – – –1G TV/radio/satellite return – C359WH C359 C359B CP3591) CM3592) – – –Blank plates1G blank plate P391 C391WH C391 C391 CP3911) CM3912) B391SS – X391MG2G blank plate P392 C392WH C392 C392 CP3921) CM3922) B392SS – X392MG

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 17

    Product overviewPREMERA wiring accessories 1.1

    Wall mounted range (contd)

    Description PREMERA COPA COPA COPA COPA COPA COPA fi x COPA fi x XTRA range c/w interior black decorative metal stainless highly surface cover interior plates1) plates 2) steel polished metal

    Spare screw capsSpare screw caps – PREMERA range P999 – – – – – – – –PREMERA mix module cover plates1G module plate moulded P901 C901WH C901 C901B CP9011) CM9012) B901SS B901HP X901MG2G module plate moulded P902 C902WH C902 C902B CP9021) CM9022) B902SS B902HP X902MG3G module plate moulded P903 C903WH C903 C903B CP9031) CM9032) B903SS B903HP X903MG4G module plate moulded P904 C904WH C904 C904B CP9041) CM9042) B904SS B904HP X904MG6G module plate assembly moulded P906 – C906 C906B CP9061) CM9062) B906SS B906HP X906MG8G module plate assembly moulded P908 – C908 C908B CP9081) CM9082) B908SS B908HP X908MG12G module plate assembly moulded P912 – C912 C912B CP9121) CM9122) B912SS – X912MG18G module plate assembly – – C918 C918B CP9181) CM9182) B918SS – X918MG24G module plate assembly – – C924 C924B CP9241) CM9242) B924SS – X924MG1G module plate moulded grey cover P901GY – C901 – CP901GY – – – –2G module plate moulded grey cover P902GY – C902 – CP902GY – – – –3G module plate moulded grey cover P903GY – C903 – CP903GY – – – –4G module plate moulded grey cover P904GY – C904 – CP904GY – – – –6G module plate assembly moulded grey cover P906GY – C906 – CP906GY – – – –8G module plate assembly moulded grey cover P908GY – C908 – CP908GY – – – –

    1)Plastic covers available in the following fi nishes

    Finish add suffi x to end of part number Example of product code

    White WH CP904WHMetallic silver SV CP904SVGold metallic GL CP904GLBlack matt BM CP904BMBlue metallic BL CP904BLGrey GY CP904GY

    2)Metal plates available in the following fi nishes

    Finish add suffi x to end of part number Example of product code

    Stainless steel SS CM904SSHighly polished HP CM904HPSatin bronze SB CM904SBPolished brass PB CM904PB

  • 18 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    Product overviewCIRCA ceiling range1.2

    CIRCA ceiling range

    Lamp activated products offer a comprehensive range for applications such as schools, nurseries, children’s bedrooms and public buildings where an extra degree of protection may be required.

    Technical characteristics:

    T2 rated•

    Full range of lampholders and battenholders•

    Each item incorporates DP switching mechanism•

    No live parts accessible when lamp is removed•

    Tool required to access terminals•

    BC3 Low Energy CFL (compact fl uorescent lamp) range is a dedicated lampholder range for use with low energy lamps.

    This range covers the most commonly used items within the home.

    Using CFL’s means that the benefi ts of energy effi cient lighting are available in the home. They are appropriate to areas where lights are left on for long periods of time such as hallways, staircases, entrances, kitchens, bedrooms and bathrooms.

    The most versatile option is to use a pendant or battenholder, a direct substitute for a normal BC lampholder. There is no extra installation time and is safe and easy to do.

    Why use the BC3 range?

    The range will accept standard UK size lampshades and require no adjustment.•

    The house owner is not restricted to the wattage of lamp by the lampholder. The same • BC3 lampholder will accept a range of wattages to suit the customers needs.

    BC3 offers a cost effective solution to the developer and contractor.•

    The range of lampholders offered meets all the normal requirements for • housing - pendant sets, battenholders and angled battenholders.

    Reduced wattage and heat generated by CFL means a wider • choice of decorative lampshades for the home.

    Lamps are CE marked and meet latest standards – IEC 60969 and IEC 60901.•

    Dedicated 3 pin ‘J’ slot lampholders and 3 pin BC lamp bases.•

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 19

    Product overviewLSC plug-in lighting system 1.3

    LSC plug-in lighting system

    The BS 7001 LSC (Luminaire Supporting Coupler) system is recognised as the industry standard interface, offering complete changeability with other manufacturers’ products. To meet the increasing industry demand for LSF cable, Eaton now offers both 3 and 4 pin versions with low smoke and fume cable.

    Both versions provide considerable benefi ts for the specifi er, contractor and end user. Litelink represents a signifi cant advance in the safety and ease of installation of lighting points.

    A range for all Commercial, Industrial and Domestic projects•

    Designed for ease of installation•

    Cable available in 1, 2 and 3m lengths with HR (Heat Resitant) • and LSF (Low Smoke and Fume) options

    Pre-fl exed 3 and 4 pin products with either 0.75mm• 2 or 1.00mm2 cable

    High quality, reliable, safe range of products•

    3 pin system

    This version has a wide range of applications in many commercial and industrial environments. Its technical and design features are supplemented with a full range of plug, outlets, assemblies, pendants and mounting boxes. In use, it provides fl exibility for the specifi er, easy installation for the contractor and convenience for the end users.

    3 pin plugs can be used safely in 4 pin outlets•

    LSC pre-wired ceiling assembly with 2 or 3m of cable, ideal for suspended ceiling lighting•

    Spacious easy wire plug with quick cover release screws•

    Bases will take up to 2 x 4.00mm• 2 cables

    4 pin system

    This version has been specifi cally designed for applications where an extra live conductor is required i.e. emergency lighting. It has all the benefi ts of the 3 pin system, but the auxiliary live conductor gives greater fl exibility in switching capabilities. It can also be used as a time delay trigger mechanism and offers greater control over multi-lamp luminaires.

    Red plug top and cover ensures easy identifi cation of 4 pin circuit•

    The fi rst 4 pin system to comply with BS 7001•

    Large outlet terminals will take up to 2 x 4.00mm• 2 cable

    Terminal access designed to aid cable installation on outlet and plug•

    LDU Multi-outlet Box

    The LDU Multi-outlet boxes utilise the LSC ‘plug-in’ lighting interface allowing luminaires to be plugged in, providing safety without isolation of the circuit. The LDU (Lighting Distribution Unit) incorporates LSC outlets which accept both Eaton’s 3 and 4 pin plugs.

    The 4 pin plug uses the fourth auxiliary socket contact for emergency lighting requirements.

    6, 8 and 10 outlet units available•

    Will accommodate 3 or 4 pin applications•

    Separate back box to enable fi rst fi x with simple plug connectors for front cover•

    Complies with the recognised industry interface BS 7001•

    Extensive range of pre-wired plugs available in both HR (Heat • Resistant) and LSF (Low Smoke and Fume) cable

    Mounting options – wall, ceiling, trunking or suspension•

    Makes life easy – no need for on-site wiring of individual fi ttings•

    Steel box for harsh environments•

    Interchangeable front covers (6, 8 and 10) to enable, if required, expansion at a later date•

  • 20 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    Product overviewMemera consumer units and devices1.4

    MEM� series Memera consumer units

    The Memera range of consumer units provide a broad scope of products to meet the requirements of the 17th edition of the wiring regulations. This well established range offers moulded and metalclad units for both surface and fl ush mounting applications.

    All units have the ability to accommodate a wide range of ancillary and comfort function devices.

    The moulded range provides a suite of boards with 1–19 outgoing ways which can be coupled together to make multi rail confi gurations. With a fl exible design that enables speedy on-site confi gurations this installer friendly unit ensures speed and ease of installation.

    All Memera consumer units comply to BSEN 60439 and are IP30 rated.

    Moulded unit features:

    • A solid base which can be fitted to all surfaces without the need for a separate back plate.

    • Elongated keyhole fixings and optional flexing points compensate for irregularities in the surface and simplify alignment of the box.

    • Quick release pan assembly including all neutral links and terminals.

    • Quarter turn quick release cover screws.

    • Base and cover provided with ample ‘cut outs’ which can be easily removed.

    • A clip-in earth bar can be removed to give full access to the base.

    • Snappable busbar enabling easy configuration on site.

    All moulded consumer units are supplied with a combined pictorial installation guide and a high quality circuit identifi cation way label which is easy to use and gives the fi nishing touch to a professional job.

    Metalclad unit features:

    • Sturdy steel enclosure with ample circular knock outs to allow the mounting of conduit or cable glands.

    • Large removable appertures in back of enclosure to allow cable access from the rear.

    • Snappable busbar enabling easy configuration on site.

    • Twin rail units available with up to 38 outgoing ways.

    All metalclad consumer units are supplied with a comprehensive label kit to complete the installation.

    Factory Built Assemblies (FBA) features:

    • Moulded or metal case construction, single rail or dual rail metal.

    • Configured with outgoing protective devices to customer requirements.

    • Can be fitted with other modular devices including timers, contactors and relays.

    • Can also be fitted with additional components including kWh meters, sensors, other devices and internal wiring as required.

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 21

    Product overviewMemera consumer units and devices 1.4

    Memera moulded consumer units – features and benefi ts

    • Memera consumer units are factory assembled and include the main controlling devices. All that’s required is the fitting of the MCBs etc, and the busbar which is provided in every unit securely held in it’s transit carrier.

    • The compact Memera range is ideal for domestic and light commercial applications.

    • The range of units provides various solutions to the 17th edition wiring regulations, with grouped RCD outgoing sections as well as accommodating multiple RCBO devices.

    • Dual tariff units with multiple incoming devices are also available.

    • Manufactured to BSEN 60439-3.

    • Degree of protection IP30.

    Quick release cover fasteners, saves installation time

    Magnolia colour to blend with any décor

    Strong and fl exible moulding material

    High quality clear sub circuit identifi cation labels

    Cover provided with cut-outs for larger trunking

    Supplied with comprehensive user instruction guide

    Takes standard EAD MCBs, RCBOs and other modular devices

    Modern, stylish aesthetics

    Maximised wiring space for RCBOs when incorporated within the installation

    Full door covers all devices

  • 22 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    Memera moulded consumer units – features and benefi ts (continued)

    • All Memera consumer units use MCBs and RCBOs for final sub-circuit protection and some also feature the variable split load design which allows on-site configuration of the number of ways allocated to each main section.

    • The units are supplied with a combined pictorial installation guide and a high quality circuit identification way label which is easy to use and gives the finishing touch to a professional job.

    • Dual RCD isolator controlled units offer grouped 30mA protection on all circuits with the ability to also connect RCBOs directly off the main switch.

    • Comprehensive sub circuit terminal numbering system. This easy, but clever way to distinguish individual circuit wiring terminations is as simple as 1,2,3. Typically, all isolator circuits utilise numbers from 1–16 whilst RCD controlled circuits use 21–36. Therefore, no need for last minute re-numbering of circuits. All numbers work away from the main or secondary controlling devices in conjunction with the MCB etc. All variations of split load units are catered for ensuring each circuit has its own unique circuit number.

    Optional fl exiblefi xing point

    Quick release and removalof pan assembly

    Solid base – no separateback plate needed

    DIN rail position createsmore wiring space

    Combination screw heads on all internal screws

    Removable busbar shield

    Neutral and earth bars located on removable pan assembly

    Combination screw headson all internal screws

    Base provided with amplecut-outs, removable byknife blade or hacksaw

    Comprehensive sub circuit terminal numbering system

    Cover location guides –saves installation time

    Product overviewMemera consumer units and devices1.4

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 23

    Product overviewMemera consumer units and devices 1.4

    Memera metalclad consumer units – features and benefi ts

    Comprehensive user instructions

    Attractive modern curved moulded door

    Full door covers all devices (also available as lockable version if required)

    Modern IP30 robust steel enclosure with ample cable knockouts in top bottom and rear faces

    High quality clear sub circuit identifi cation labels

    Cover secured by means of combination head screws

    Cover designed to stay open as required

    • Modern stylish appearance fully assembled with ample knock-outs in steel enclosure to suit all applications. The units are delivered factory assembled and fully equipped with all main controlling devices and interconnections. All that is required is to remove and install the busbar which is secured in the rear of the unit and fit the outgoing devices.

    • The Memera metalclad consumer units are ideal for both domestic and light commercial applications where a more robust metal enclosure is needed.

    • The units are available with single or multiple incoming device options as well as the various dual RCD combinations widely used to enable compliance with the 17th Edition wiring regulations.

    • Manufactured to BSEN 60439-3.

    • Degree of protection IP 30.

  • 24 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    Memera metalclad consumer units – features and benefi ts (continued)

    Preformed knockouts forease of installation

    Loose busbar supplied attached to the rear of enclosure

    Earth and Neutral terminalblocks are fully rated to 100A

    Complete shrouding of all live parts

    Modular control devices can be fi tted in place of MCBs

    Ample wiring space acrossthe full length of the busbar

    Freely confi gurableRCD ways on split load boards

    Distinct wiring zones for easierand neater installation

    • The Memera metalclad consumer units use MCBs and RCBOs for final sub circuit protection, and can also accommodate a wide range of other modular devices such as timers, contactors and relays.

    • The split load and multiple RCD units all feature a variable split design with busbars that can be simply split on site to enable the exact configuration to be achieved.

    • Dual RCD units incorporating an isolator main switch and providing grouped 30mA RCD protection in two zones, can also be configured with some high integrity ways fed directly off the isolator. Ideal for protecting selected circuits with independent RCBOs.

    • Full instructions and a comprehensive labelling kit enable the installation to be completed professionally with all the appropriate internal warning and circuit identification labels.

    Product overviewMemera consumer units and devices1.4

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 25

    Product overviewMemera consumer units and devices 1.4

    Memera moulded consumer units – quick and easy installation

    Step 1 – Prepare for base installation

    On removal of the main cover using the quick release cover fasteners, the complete pan assembly can be withdrawn from the base by means of the unique clip feature. The busbar is then removed from its retaining clip.

    Step 2 – Cut-out and cable preparation

    Using any of the easily removable cut out sections, the cables may be prepared. The empty base is then fi tted to the wall without obstruction to the cable bunch..

    Step 4 – Internal wiring

    On re-fi tting of the pan assembly, the pre-prepared cables can be wired to the devices. Circuit testing can then be carried out at the appropriate time.

    Step 3 – Pan assembly preparation

    MCBs and RCBOs are fi tted to the pan assembly in the appropriate positions. The busbar is then snapped to the required length (split load units only) and fi xed to the device terminals. On completion the pan assembly is clipped into position.

    Step 5 – Completion of internal wiring and labelling

    Once all wiring is completed, the push-fi t busbar cover is slotted into position and the internal labels can be applied.

    Step 6 – External identifi cation labels and fi tting of main cover

    The external circuit identifi cation labels are now applied. The cover is then replaced easily and quickly using the quarter turn fasteners.

  • 26 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    17th Edition regulations and consumer units

    The advent of the 17th Edition of the Wiring regulations brought with it new challenges for installers and manufacturers alike, one such challenge involves the much greater use of RCDs within the electrical installation. The regulations BS 7671:2008 now incorporate amendment No.1 2011.

    Regulation 411.3.3.

    States that additional protection by means of a 30mA RCD is to be provided for all socket outlets with a rated current not exceeding 20A for use by ordinary persons. The only exceptions allowed are for socket outlets for use under the supervision of “skilled” or “instructed persons” e.g. some commercial / industrial locations, or a specifi c labelled socket provided for connection of a particular item of equipment, e.g. a freezer circuit.

    Regulation 701.411.3.3

    In specifi c locations such as those containing a bath or shower there is a requirement now to provide RCD protection on all circuits, including the lighting and shower circuits.

    Regulation 314.1 & 2

    Requires that every installation shall be divided into circuits as necessary to avoid danger and minimise inconvenience, in the event of a fault. Also reducing the possibility of unwanted RCD tripping, due to excessive protective conductor currents but not due to an Earth fault. Separate circuits may be required for parts of the installation, which need to be separately controlled in such a way that they are not affected by the failure of other circuits. The appropriate subdivision should take account of any danger arising from the failure of a single circuit eg. an RCD trip on a socket outlet causing the unwanted failure of a lighting circuit and its associated hazards.

    Regulation 522.6.102

    Now requires a much greater use of RCDs to protect the wiring concealed in walls or partitions even where installed in previously defi ned “Safe Zones”. These regulations effectively mean that all concealed wiring at a depth of less than 50mm from the surface now requires protection by a 30mA RCD unless provided with earthed mechanical protection.

    Application of RCDs

    The 17th Edition of the IEE wiring regulations ( BS7671 ), detail a number of regulations relating to protection against electric shock, including the need for additional protection.

    The use of RCDs (Residual Current Devices) with a residual operating current not exceeding 30mA is the recognised means of providing this additional protection in the event of failure of the provision for basic protection and or the provision for fault protection or carelessness by users.

    Such RCDs should not be used to provide the sole means of protection and do not obviate the need to apply one or more of the recognised protective measure as detailed in the regulations.

    Under the new regulations an installation is required to incorporate one or more RCDs, depending upon the circumstances. Such instances include:-

    • All socket outlets not exceeding 20A, but with certain exceptions. One such exception would be permitted for a specific labelled or otherwise suitably identified socket outlet for connection of a particular piece of equipment.

    • Mobile equipment with a current rating not exceeding 32A for use outdoors

    • Electrical circuits installed under “Special installations and locations” as defined in Part 7 of the regulations e.g. Swimming Pools / Saunas.

    • All electrical circuits, including shower and lighting circuits etc. in rooms with a fixed bath or shower e.g. bedrooms and en-suite bathrooms.

    In addition to the protection requirements of the outgoing circuits / loads, the requirements of the installed cabling also must be taken into account.

    Where a cable is concealed in a wall or partition at a depth of less than 50mm from the surface, even if installed in the “safe zone”, if not provided with earthed mechanical protection e.g. Metal trunking or conduit, it must be provided with additional protection by means of a 30mA RCD.

    Whilst it may be desirable to have one or two circuits fed via an unprotected circuit e.g. an identifi ed / dedicated freezer circuit, the installation of the wiring may still dictate that the circuit must be RCD protected. The protection of a circuit by means of a 30mA RCD is also required where cables are concealed in walls constructed with metal stud partitions which are common in modern buildings, irrespective of the depth from the surface, unless provided with protection in the form of earthed metallic covering, trunking, conduit or other mechanical protection so as to avoid damage to the cable during installation or construction of the wall.

    IEE Regulations and British Standards are subject to amendments. This Eaton guide to consumer unit solutions is not a substitute for the regulations which should always be used for all types of electrical installations and design work.

    Product overviewMemera consumer units and devices1.4

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 27

    Product overviewMemera consumer units and devices 1.4

    Regulations Relating to Example Additional Protection

    411.3.3 All socket outlets up to 20A – Upstairs sockets 30mA RCD rating for general use by – Downstairs sockets ordinary persons – Kitchen sockets – Cooker outlet with integral – 13A socket outlet – Plus any other sockets rated up to 20A – including garage sockets701.411.3.3 All electrical circuits in a room – Shower circuit 30mA RCD with a fi xed bath or shower – Lighting circuit – Heating circuit – Ventilation circuit – Shaver socket – Socket outlets522.6.100 All electrical circuits buried in a All concealed wiring 30mA RCD522.6.101 wall or partition at less than – Socket outlets522.6.103 50mm and without mechanical – Lighting circuits protection – Smoke alarm – Burglar alarm

    In summary

    Installation design

    The 17th edition wiring regulations BS7671 applies to all new installations designed after 30th June 2008, and there are various options that must be considered in order to satisfy these requirements. Starting with the wiring scheme and the building design, consideration must be given to the purpose of the building, and to the persons who will be using the installation, as different regulations will be applicable, e.g. is the installation under the control of skilled or instructed persons, or ordinary persons, or perhaps the installed location contains a bath or shower. Answers to these points will start to focus in on the regulations that need to be followed.

    Consideration must be given to the way cables will be fi tted within the installation, either on the surface in trunking or conduit, or else concealed beneath the surface of the wall either buried within the plaster or inside the cavity of a hollow partition wall. The chosen installation methods and wiring accessories or loads being fed, will also dictate whether additional protection by means of 30mA RCDs is required on those circuits or not.

    The wiring regulations are open to interpretation in some areas, where reference is made to “minimise inconvenience in the event of a fault”, acceptable levels of inconvenience can be somewhat subjective.

    In most circumstances the regulations now dictate that a consumer unit will be required to have two or more 30mA RCDs, enabling the load circuits to be spread over a number of RCD protected zones or outgoing ways.

    However, the most comprehensive and effective solution, and one that is guaranteed to fully meet the requirements of the regulations is to equip each and every circuit with it’s own individual 30mA RCBO.

    The examples shown on the next page illustrate just some of the many options available, to a contractor, to achieve a 17th Edition compliant installation. Some options provide a much higher level of circuit integrity than others. The fi nal choice of which may well be made based on this and the cost/ease of the installation.

  • 28 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    Consumer unit solutions

    There are many ways of providing RCD circuit protection to meet the demands of the new regulations.

    The most comprehensive solution would be to provide individual RCBO protection on each and every out going circuit from a consumer unit. Hence the use of a consumer unit such as a 12 way isolator controlled board. eg. EAD12 fi tted with up to 12 x RCBOs or the EAD11R 11 way unit with additional cabling space to accommodate the RCBOs.

    The next level down would be to provide an isolator controlled dual RCD consumer unit feeding two RCD board sections. eg. EAD12H80H80D or EAD12H80H63D fi tted with up to 12 x MCBs

    Such a dual RCD board could also be provided with some unprotected ways controlled by the main switch to enable a supply to any individual circuits that don’t require RCD protection or else require individual RCBO circuit protection.eg. EAD12H80H803D or EAD12H80H633D fi tted with up to 15 x MCBs

    A conventional split load board such as an EAD14H80D could have additional RCBOs fi tted to the non protected side allowing a mixture of Group RCD protected circuits and Individual RCBO protected circuits.

    Consumer units are already available with RCD incomers of 30mA sensitivity such as EAD12H80, EAD12H100. However, single RCD controlled units on their own are unlikely to satisfy regulation 314.1 and 2.

    Product overviewMemera consumer units and devices1.4

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 29

    Product overviewMemera consumer units and devices 1.4

    Switch and protection devices

    Residual Current Circuit Breakers (RCCBs)

    The Eaton range of Residual Current Circuit Breakers without integral overload protection (RCCBs), provide protection solutions to a wide range of applications.

    The Eaton range of double pole RCDs are available with 10mA, 30mA, 100mA and 300mA sensitivities.

    Technical characteristics

    • Modular design, DIN rail mountable, two modules wide.

    • Double pole RCD for commercial and residential applications

    • Rated short circuit capacity 10kA with fuse back up

    • Manufactured and tested to IEC/EN 61008

    • Trip sensitivities 10, 30, 100 and 300mA

    • Positive contact indication

    • Test button

    Compact Residual Current Circuit Breakers with Overcurrent protection (RCBOs)

    The Eaton range of combined Residual Current Circuit Breakers with integral Overload protection (RCBOs), combine the highest level of protection for both people and circuits in a single one module device.

    The Eaton range of 6kA RCBOs are available from 6A to 45A in both B and C curve with 30mA trip sensitivity and fully comply to IEC/EN 61009

    Technical characteristics

    • New compact modular design, DIN rail mount-able, one module wide. Providing significant wiring space above the module.

    • Single module combined MCB/RCD unit

    • Solid neutral

    • Positive contact indication

    • Rated currents from 6–45A in both B and C characteristic

    • Trip sensitivity 30mA (others available)

    • Rated breaking capacity 6kA

    • Test button

    Main load disconnector switch (isolator)

    The Eaton range of modular Isolators are available in single pole, double pole and single pole with switched neutral arrangements.

    Technical characteristics

    • Compact modular design, DIN rail mountable, one or two modules wide.

    • Positive contact indication

    • Rated at up to 12.5kA these switches are fully tested to IEC 60947-3 for AC23 duty at 240VAC

    • Terminal capacity 2.5–50 mm2

    Single pole & neutral switchfuse

    The Eaton wall mounted switchfuse 800KMF is a fully moulded, compact wall mounted, SP&N unit rated at up to 80A, complying with EN 60947-3 for duty AC22B, 240v AC. The unit is fi tted with a fully insulated pull out fuse carrier, which will accommodate HRC fuse links complying with BS 88-3 (formerly BS 1361) and rated between 45–80A.

    Miniature Circuit Breakers (MCBs)

    The Eaton range of 6kA high performance Miniature Circuit Breakers (MCBs) has been designed to meet the latest UK, European and International standards, with ratings from 2A up to 63A as standard.

    The Eaton 6kA miniature circuit breakers are designed and tested in accordance with IEC/EN 60898 and are available in both B and C characteristic curve as standard

    Technical characteristics

    • Modular design, DIN rail mountable, one module wide.

    • Single pole MCB for commercial and residential applications.

    • Rated Braking Capacity 6kA to IEC/EN 60898

    • 2–63A in both type B and C characteristics

    • Positive contact indication

    • Box clamp barrier to prevent incorrect cable insertion

    • Calibrated at 40˚C

    • Can be used with both pin and comb type busbars

    • Suitable for use in Eaton consumer units and a wide range of other applications

  • 30 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    Control and Switching Devices

    Timers

    The Eaton range comprises of a wide variety of different products which include analogue timers, digital timers, twilight switches and staircase timers. Timers are available either with 50Hz net-synchronisation or quartz control. Except for net-synchronised timers all units do have self power reserve to secure the time setting and program storage in case a power interruption does occur. Twilight Switches are supplied with a remote light sensor, which can be easily installed on the outside wall where the required light intensity threshold can be simply adjusted on the modular device itself. The multifunctional staircase timer TE1 with many advanced switching facilities completes our range of timer products.

    Technical characteristics (depending on type)

    • Modular design.

    • Analogue and digital timers.

    • Time adjustment by 50 Hz net, quartz.

    • Maximum 2 channel output.

    • Manual override switching function.

    • Power reserve for all quartz, analogue and digital controlled timers.

    • Remote Light Sensor for Twilight Switching.

    Advantages of Eaton timers

    • Easily programmable on front of device.

    • Computer aided programming software available.

    • Compact 18 mm design for restricted space opportunities.

    • Separate IP40 covers are available for direct wall mounting.

    • High level of accuracy.

    • Maximum lamp load test data is available for reference.

    • Automatic summer and winter time adjustment.

    • Holiday & Random program settings.

    • High power reserve up to 10 years.

    Contactors and impulse switches

    Contactors are frequently applied for switching of lamp loads, fans, heaters or pumps in both utility as well as industrial areas.

    All contactors with ac/dc coils ensure silent operation which is further enhanced by a low power consumption.

    Optimal contacts and low heat dissipation guarantee a long lifetime of the contactor which is available in a wide range of characteristics.

    Technical characteristics

    • Designed according to IEC 60947-4-1 and IEC 61095 standards.

    • Suitable for applications in general control, heating & lighting applications.

    • Available in 20, 25, 40 & 63 A ratings with up to 4-pole contacts.

    • Coil voltages: 12 Vac/dc, 24 Vac/dc, 48 Vac/dc, 230 Vac, 220 Vdc.

    • Optional add-on auxiliary contact available.

    • DIN modular profile.

    • Spacers available to extend lifetime (it is recommended to use 1 spacer between every 2 contactors installed).

    • Day / night contactors available with manual override function.

    Advantages of Eaton contactors

    • Low inrush power for all ac/dc types.

    • Availability of combined ac/dc type contactors ensure silent operation.

    • Contactors of ac/dc coil type are operable on both ac and dc voltage. The 20A and 25A versions are also available with ac coil. All combined ac/dc type versions are equipped with surge protecion on the operating coil.

    • Equipped with contact indication.

    • Optimal quality of contacts and low heat dissipation ensure a long life time.

    Product overviewMemera consumer units and devices1.4

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 31

    Product overviewMemera consumer units and devices 1.4

    Transformers

    The Eaton bell transformer is a simple two module unit providing a dual voltage output (12V, 0.6A and 8V, 1.0A) and can be used with most commercially available door bells.

    Wireless electricity monitor

    Take control of your energy use by using the efergy wireless electricity monitor. It displays instant power, costs, historical and average data and estimated CO2 emissions. Discover and reduce the size of your carbon footprint by monitoring the cost of using your home appliances and lighting. It’s also fun and educational for all the family.

  • 32 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    Product overviewRF building automation and controls1.5

    Switching actuator

    switches lights, pumps, ventilation and heating systems, saunas, ... any electrical consumer product.

    Shutter actuator

    for controlling blinds, shutters, mixing values, etc.

    Dimming actuator

    switches and dims lights and light environments.

    Analogue actuator

    controls devices such as mixers, dimmers and fl uorescent lamps.

    Temperature input unit

    measures temperature and controls shading and heating.

    Home manager

    the universal genius for centralised building management, operation, and display.

    Room manager

    the operating and display unit – easy to handle and easy to read.

    Room controller

    regulates and controls heating and shading.

    Binary input unit

    for integrating conventional switches, window contacts, and signal contacts.

    Push-button unit

    for lighting, shading, etc.

    PIR motion sensor

    controls lights depending on movement and brightness.

    Adaptor plug

    switches and dims living room fountains, aquaria, etc.

    System components include sensors, actuators and control/communication devices

    See chapter 10 for more information.

    Suitable for residential and commercial applications, Eaton’s Moeller xComfort range of building automation products has been specifi cally designed to provide centralised control of all the electrical equipment in order to maximise energy savings, comfort, safety and security.

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 33

    PREMERA white moulded 2

    The PREMERA White Moulded range offers a

    modern aesthetically edged styled appearance

    whilst utilising the well established UREA material

    with its inherent MRSA germ protection properties

    ideal for kitchens, bedrooms and living rooms.

    Each product is supplied with an optional

    screw cap facility to hide unsightly screws.

    Essential supply products are offered enabling circuits to

    be highlighted effectively with unmistakable red rockers

    and fuse drawers without compromising their suiting

    with other standard accessories. Grey covers are offered

    to provide solutions to the latest Building Regulations.

    2.1 10A WALL SWITCHES 10A standard switches ................................................................................................................................................................ 35 3 Pole fan isolator switches ......................................................................................................................................................... 35

    10A broad rocker switches .......................................................................................................................................................... 35

    16A hotel switch .......................................................................................................................................................................... 35

    Dimmer switches ........................................................................................................................................................................ 36

    2.2 SOCKET OUTLETS 13A switched sockets .................................................................................................................................................................. 37 13A RCD socket ........................................................................................................................................................................... 38

    Unswitched sockets .................................................................................................................................................................... 38

    15A sockets ................................................................................................................................................................................. 38

    Shaver socket .............................................................................................................................................................................. 38

    2.3 FUSED CONNECTION UNITS 13A connection units – unswitched ............................................................................................................................................. 39 13A connection units – switched ................................................................................................................................................. 39

    2.4 POWER SWITCHES 20A switches ............................................................................................................................................................................... 40 45A/50A switches........................................................................................................................................................................ 40

    2.5 CABLE OUTLETS AND BLANK PLATES Cable outlets ................................................................................................................................................................................ 41 Blank plates ................................................................................................................................................................................. 41

    Continued overleaf

  • 34 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    2.6 COMMUNICATION OUTLETS Phone/data outlets ...................................................................................................................................................................... 42 Communication outlets ............................................................................................................................................................... 42

    2.7 PATTRESSES AND ANCILLARY ITEMS Pattresses .................................................................................................................................................................................... 43 Junction boxes and plugs ............................................................................................................................................................ 43

    2.8 PREMERA MIX MODULE PLATES Modular plates/grids .................................................................................................................................................................... 44

    PREMERA white moulded2

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 35

    PREMERA white mouldedWall switches 2.1

    P021 10A switches

    To BSEN 60669-1.•

    Supplied with M3.5 fi xing screws and caps. Each terminal is capable of accepting up to • 3 x 1.5mm2 conductors. All terminals are backed off, ready to accept cable.

    X-rated for fl uorescent or inductive loads.•

    Description Eaton list number

    10A 1G 1 way P01110A 2G 1 way P01210A 3G 1 way P01310A 4G 1 way P01410A 1 way bell push P01510A 1 way light symbol push P015L10A 1G 1 way push P015P10A 1G intermediate P01710A 1G 2 way P02110A 1G 2 way push P021P10A 2G 2 way P02210A 3G 2 way P02310A 4G 2 way P02410A 6G 2 way P026

    P048 3 Pole isolator switches

    To BSEN 60669-1.•

    Description Eaton list number

    10A fan isolator + fan symbol P04810A 3 pole isolator P049

    P041 10A broad rocker switches

    To BSEN 60669-1.•

    Broad rocker individual modules can be removed for replacement/• maintenance. X-rated for fl uorescent or inductive loads.

    Description Eaton list number

    10A 2G 2 way half broad switch P03210A 1G 2 way broad switch P04110A 1G 2 way push switch P041P10A 2G 2 way broad switch P04210A 1G 1 way bell push P04510A 1G 1W broad switch push P045P10A 1G intermediate broad switch P04710A 1G DP broad switch + neon P043N

    P450 16A hotel switch

    To BS 60669-1. •

    Each terminal is capable of accepting up to 3 x 1.5mm• 2 conductors. Suitable for surface mounting.

    Time delay.•

    Description Eaton list number

    16A hotel switch P450

  • 36 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    PREMERA white mouldedWall switches2.1

    P9551 Non-european rotary dimmers

    Description Eaton list number

    500W 1G 1W tungsten non-european P9551500W 2G 1W tungsten non-european P95521000W 1G 1W tungsten non-european P951160–500W fan controller non-european P9751

    P9131 Push on/push off action dimmers

    To BSEN 60669-1. •

    Description Eaton list number

    250W 1G 2W push tungsten P9131250W 2G 2W push tungsten P9132400W 1G 2W push tungsten P9141400W 2G 2W push tungsten P91421000W 1G 2W push tungsten (2 gang plate size) P91111–10V 1G 1W analogue P9101

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 37

    PREMERA white mouldedSocket outlets 2.2

    P632N 13A double pole switched sockets outboard rockers

    To BS 1363: Part 2. •

    2 earth terminals and outboard rockers.•

    Terminals capable of accepting up to 3 x 4mm• 2 or 2 x 6mm2 conductors.

    Description Eaton list number

    13A 2G DP switched socket P63213A 2G DP switched socket – grey P632GY13A 2G DP switched socket + neon P632N13A 2G DP switched socket + red rockers P632RR13A 2G DP switched socket – red coverplate P632RED

    P651 13A 1G double pole non-standard/clean earth switched sockets

    Non-standard socket interface to BS 5733 with clean earth facility.•

    2 clean earth terminals and 2 standard earth terminals on each product.•

    Description Eaton list number

    13A 1G DP switched socket P65113A 1G DP switched socket + neon P651N

    P652 13A 2G double pole non-standard/clean earth switched sockets

    Outboard rockers.•

    Non-standard socket interface to BS 5733 with clean earth facility.•

    2 clean earth terminals and 2 standard earth terminals on each product.•

    Description Eaton list number

    13A 2G DP switched socket with 2E terminals P65213A 2G DP switched socket + red rockers with 2E terminals P652RR

    P611 13A single pole switched sockets

    To BS 1363: Part 2.•

    Terminals capable of accepting up to 3 x 4mm• 2 or 2 x 6mm2 conductors.

    Description Eaton list number

    13A 1G SP switched socket P61113A 2G SP switched socket P612

    P622 13A double pole switched sockets inboard rockers

    To BS 1363: Part 2. •

    2 earth terminals and inboard rockers.•

    Terminals capable of accepting up to 3 x 4mm• 2 or 2 x 6mm2 conductors.

    Description Eaton list number

    13A 1G DP switched socket P62113A 1G DP switched socket – grey P621GY13A 1G DP switched socket + neon P621N13A 1G DP switched socket + red rockers P621RR13A 1G DP switched socket red plate cover P621RED13A 2G DP switched socket P62213A 2G DP switched socket + neon P622N13A 2G DP switched socket + red rockers P622RR

  • 38 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    P370 Shaver supply unit

    To BSEN 61558-2-5. •

    Mounting box – • F4530 (46mm deep).

    Description Eaton list number

    Shaver socket dual voltage 230V/110V AC P370

    PREMERA white mouldedSocket outlets2.2

    P672 13A 2G double pole clean earth switched sockets

    Outboard rockers. •

    Standard socket interface to BS 1363 with clean earth facility.•

    2 clean earth terminals and 2 standard earth terminals on each product.•

    Description Eaton list number

    13A 2G DP switched socket with 2E terminals P672

    P111 13A socket outlets

    To BS 1363: Part 2.•

    Terminals capable of accepting up to 3 x 4mm• 2 or 2 x 6mm2 conductors.

    2 earth terminals on P112.•

    Description Eaton list number

    13A 1G unswitched socket P11113A 2G unswitched socket P112

    P686 13A double pole RCD socket outlet – passive

    Added protection against electrocution. •

    30mA protection.•

    Passive – The contacts on the passive device remain closed when the mains supply is • interrupted – this type is suitable for applications such as fridge freezers etc.

    To BS 7288•

    Description Eaton list number

    13A 2G RCD protected socket passive 30mA P686

    P415 15A socket outlet

    To BS 546.•

    Description Eaton list number

    15A 1G switched socket P415

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 39

    PREMERA white mouldedFused connection units 2.3

    P220 13A fused connection units with optional cable outlets – unswitched

    To BS 1363: Part 4.•

    Live and Neutral accept 2 x 2.5mm• 2 cables. Suitable for surface mounting.

    P212 adaptor plate for use with bottom entry cable outlet.•

    Description Eaton list number

    13A unswitched connection unit P22013A unswitched connection unit + red fuse drawer P220RR13A unswitched connection unit + neon P220N13A unswitched connection unit fi tted + 3A fuse P22313A unswitched connection unit + neon fi tted with 3A fuse P223N

    P221N 13A double pole fused connection units with optional cable outlets – switched

    To BS 1363: Part 4.•

    Live and Neutral accept 2 x 2.5mm• 2 cables. Suitable for surface mounting.

    P212 adaptor plate for use with bottom entry cable outlet.•

    Description Eaton list number

    13A DP switched connection unit P22113A DP switched connection unit marked ‘boiler’ P221BO13A DP switched connection unit marked ‘central heating’ P221CH13A DP switched connection unit marked ‘cooker hood’ P221CKH13A DP switched connection unit marked ‘dishwasher’ P221DW13A DP switched connection unit – grey P221GY13A DP switched connection unit marked ‘extract fan’ P221EF13A DP switched connection unit marked ‘refrigerator’ P221R13A DP switched connection unit + red rocker P221RR13A DP switched connection unit marked ‘washing machine’ P221WM13A DP switched connection unit + neon P221N13A DP switched connection unit + neon – grey P221NGY13A DP switched connection unit + neon + red fuse drawer P221NRR13A DP switched connection unit + neon marked ‘water heater’ P221NWH13A DP switched connection unit + neon marked ‘boiler’ P221NBO13A DP switched connection unit + neon marked ‘dishwasher’ P221NDW13A DP switched connection unit + neon marked ‘fridge freezer’ P221NFF13A DP switched connection unit + neon marked ‘hob’ P221NHO13A DP switched connection unit + neon marked ‘tumble dryer’ P221NTD13A DP switched connection unit + neon marked ‘washing machine’ P221NWM13A DP switched connection unit fi tted with 3A fuse P224

  • 40 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    P401N 20A double pole switches with optional cable outlet

    To BSEN 60669-1.•

    Supply terminals accept 3 x 2.5mm• 2 conductors. Load terminals accept 2 x 2.5mm2 conductors.

    P212 adaptor plate for use with bottom entry cable outlet.•

    Description Eaton list number

    20A DP switch P40120A DP switch marked ‘water heater’ P40320A DP switch + neon P401N20A DP switch + neon marked ‘water heater’ P403N20A DP switch + neon marked ‘air conditioner’ P404N

    P425N 45A double pole cooker control unit

    To BS 4177.•

    Description Eaton list number

    45A DP cooker control unit P42545A DP cooker control unit + neon P425N

    P421N 50A double pole switches

    To BSEN 60669-1.•

    Description Eaton list number

    50A DP switch 2G plate P42150A DP switch + neon 2G plate P421N50A DP switch marked ‘cooker’ 2G plate P42350A DP switch + neon marked ‘cooker’ 2G plate P423N50A DP switch + neon marked ‘air conditioner’ 2G plate P424N50A DP switch + neon 1G plate size P422N50A DP switch + neon 1G plate size – grey P422NGY50A DP switch + neon 1G plate size marked ‘cooker’ P426N50A DP switch + neon 1G plate size marked ‘air conditioner’ P427N

    PREMERA white mouldedPower switches2.4

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 41

    PREMERA white mouldedCable outlets and blank plates 2.5

    P345 Cable/cooker outlet plates

    To BS 5733.•

    Description Eaton list number

    45A DP cable outlet with terminal block P34520A fl ex outlet plate P210Cable outlet adaptor plate for 20A switch/3A fused connection unit P212

    P212

    P392 Blank plates

    Description Eaton list number

    1 gang blank plate P3912 gang blank plate P392

    Accessories

    Description Eaton list number

    Spare screw caps – PREMERA P999

  • 42 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    P362 Telephone outlets

    Description Eaton list number

    1G telephone outlet single master P3601G telephone outlet single secondary P3611G telephone outlet single RJ11 P362

    P352 TV/FM co-axial outlets

    P353• and P354 isolated outlets for use in multi-outlet aerial systems. Suitable for full band width 40–860MHz. Single outlet TV/FM isolated co-axial socket suitable for ‘T’ box use with a single co-axial lead. Isolated 2 gang TV/FM diplexer socket double resistive outlet suitable for TV/FM and ‘T’ box use with a single co-axial down lead.

    Description Eaton list number

    1G TV co-axial outlet P3511G TV co-axial outlet dual clamp P351D2G TV co-axial outlet P3521G TV/FM isolated co-axial outlet P3532G TV/FM diplexer co-axial outlet P354

    P356 TV and satellite co-axial outlets

    Suitable for full band width 40–860MHz.•

    Description Eaton list number

    1G SAT outlet P3552G TV/SAT outlet P356

    P357 Screened TV/FM/radio/satellite co-axial outlets

    Suitable for full band width 40-860MHz. Will accept digital IR return signal through TV point.•

    Description Eaton list number

    2G TV/radio outlet screened P357

    PREMERA white mouldedCommunication outlets2.6

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 43

    PREMERA white mouldedPattresses and ancillary items 2.7

    F4501 Mounting boxes

    Description Eaton list number

    1G pattress 16mm deep F45001G pattress 28mm deep F45012G pattress 28mm deep F45022G conversion pattress 25mm deep F45102G pattress 40mm deep with cable clamp F45112G pattress 46mm deep for shaver supply unit F45301G pattress 45mm deep F4570

    F3368 Ancillary products

    Description Eaton list number

    13A non-standard plug F336810W connection box F5099

  • 44 WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012

    P903 Modular coverplates

    Suitable for use with PREMERA mix module range.•

    Dimensions: 1–2G: 86mm x 86mm 3–4G: 86mm x 146mm 6–8G: 146mm x 150mm• 12G: 150mm x 210mm 18G: 210mm x 210mm 24G: 210mm x 270mm

    Supplied complete with mounting frames/earth straps.•

    Description Eaton list number

    1G module coverplate moulded c/w earth strap P9012G module coverplate moulded c/w earth strap P9023G module coverplate moulded c/w earth strap P9034G module coverplate moulded c/w earth strap P9046G module coverplate moulded c/w mounting frame P906 8G module coverplate moulded c/w mounting frame P908 12G module coverplate moulded c/w mounting frame P91218G module coverplate c/w mounting frame – clip-on cover C918 + CP918WH24G module coverplate c/w mounting frame – clip-on cover C924 + CP924WH1G modular coverplate moulded – grey c/w earth strap P901GY2G modular coverplate moulded – grey c/w earth strap P902GY3G modular coverplate moulded – grey c/w earth strap P903GY4G modular coverplate moulded – grey c/w earth strap P904GY6G modular coverplate assembly moulded – grey c/w mounting frame P906GY8G modular coverplate assembly moulded – grey c/w mounting frame P908GY

    PREMERA white mouldedPREMERA mix module coverplates2.8

  • WIRING ACCESSORIES AND SINGLE PHASE DISTRIBUTION PG00400018U – March 2012 45

    PREMERA mix 3