ps20160343 - addendum 1 - bidding opportunities -...
TRANSCRIPT
FINANCIAL SERVICES GROUPSupply Chain Management
City of Vancouver, Financial Services Group Supply Management 453 West 12th Avenue Vancouver, British Columbia V5Y 1V4 Canada tel: 604.873.7263 fax: 604.873.7057 website: vancouver.ca
May 5th, 2016
INVITATION TO TENDER (“ITT”) NO. PS20160343 SKYLIGHT REPLACEMENT: VANCOUVER CITY HALL & ART GALLERY LOBBY
ADDENDUM NO. 1
RE: PART A – Appendix 3 Specifications
PLEASE ADD:
1. Abbreviated scope of work (1 page) 2. City Hall Drawings A106-A109 (4 pages)
This Addendum must be completed, and attached to your Tender form.
If you have already submitted your Tender, this Addendum shall be submitted to the Purchasing Services Office, City of Vancouver, 453 West 12th in an envelope clearly marked “ADDENDUM No. 1 to ITT No. PS20160343 Skylight Replacement: Vancouver City Hall & Art Gallery Lobby” before the closing time of 3:00:00 P.M. Vancouver Time on Thursday, May 12, 2016 Avenue, Vancouver, British Columbia, Canada, V5Y 1V4.
NAME OF VENDOR
SIGNATURE OF AUTHORIZED SIGNATORY
DATE
Contracting Specialist Dino Goundouvas
SkylightWellat3rdFloorOfficeAreaAbbreviatedscopeofwork:Thisworkincludesalllabourandmaterialsnecessarytobuildaskylightwellinthe3rdfloorofficespace.Theworkincludes:
• Removeanddisposeofdropceilingcomponentsintheaffectedarea• Supplyandinstallmin.20ga.Steelstuds,strutsandtrackstoframeskylight
well.Anchortoconcretesoffitwithpowderactuatedfastenerswithmetaltophatwasher(HiltiX-S16-P8TH)orapprovedequivalent.Finishedskylightwellcanbeapproximately¾inchlowerthantheadjacentdropceilingtoprovideasmallrevealatthedropceilingtoskylightwellinterfaceifrequiredbysiteconditions.
• Supplyandinstall½inchGypsumWallBoard(GWB)toformskylightwellandreturns.
• Mud,tape,cornerbead,sand,primeandpaintGWB.Paintcolourandsheentobeselectedbyowner.
• Relocateelectrical,dataandrelatedwiresandcablestobypassfinishedskylightwell.Allworktobecompletedwithqualifiedtrades.Junctionstobecompletedincompliancewithrelevantby-laws,codesandbestpractice.
• Allservicestobeun-interruptedduringnormalworkinghours.• Existingsprinklertoremaininplace.Relocationnotrequired.Paintpipeto
blendintoskylightwell.• Prepareandpaintallexposedconcreteandtrimtomatchskylightwell.• Cleanexistinglightdiffuserpanelsonbothsides.• Reinstatedropceiling.Ensureceilingtilesizesareadjustedtoprovidean
aestheticallyacceptablefinish.
PROJECT #:
ISSUED FOR:
DRAWN BY:
DRAWN ON:
CHECKED BY:
SCALE: N.T.S
REVISIONS:
SHEET TITLE:
CLIENT REVIEW
A.J.
A.J.
20151101
VANCOUVER CITY HALL
453 W. 12th AVENUE,VANCOUVER, BC
#201 - 33 East 8th AvenueVancouver, BC, V5T 1R5
Phone: 604-255-0992Fax: 604-255-1054
MAY 02, 2016
SKYLIGHT
A106
NEW 1x6" PAINT GRADE WOOD TRIM NOTCH TO SUIT SITE CONDITIONS
EXISTING SPRINKLER TO REMAIN & PAINT
EXISTING ELECTRICAL CONDUIT
EXISTING PARTITION WALL
EXISTING SPRINKLER PIPE TO REMAIN & PAINT
MISC. CABLES, CONDUITS, ELECTRICAL & DATA
S01
A107
S02
A108
S03
A10
8
NEW 1/2" GWB
NEW 3 5/8" DIAGONAL METAL STUD @ 24" O.C.
EXISTING ROOF SYSTEM
PROJECT #:
ISSUED FOR:
DRAWN BY:
DRAWN ON:
CHECKED BY:
SCALE: N.T.S
REVISIONS:
SHEET TITLE:
CLIENT REVIEW
A.J.
A.J.
20151101
VANCOUVER CITY HALL
453 W. 12th AVENUE,VANCOUVER, BC
#201 - 33 East 8th AvenueVancouver, BC, V5T 1R5
Phone: 604-255-0992Fax: 604-255-1054
MAY 02, 2016
SKYLIGHT - SECITION 01
A107
NEW 3 5/8" METAL STUD FRAMED STRUCTURE
NEW 1/2" GWB
NEW 3 5/8" DIAGONAL METAL STUD @ 24" O.C.
EXISTING ROOF SYSTEM
NEW 1x6" PAINT GRADE WOOD TRIM NOTCH TO SUIT SITE CONDITIONS
PROJECT #:
ISSUED FOR:
DRAWN BY:
DRAWN ON:
CHECKED BY:
SCALE: N.T.S
REVISIONS:
SHEET TITLE:
CLIENT REVIEW
A.J.
A.J.
20151101
VANCOUVER CITY HALL
453 W. 12th AVENUE,VANCOUVER, BC
#201 - 33 East 8th AvenueVancouver, BC, V5T 1R5
Phone: 604-255-0992Fax: 604-255-1054
MAY 02, 2016
SKYLIGHT - SECITION 02
A108
NEW 1/2" GWB
NEW 3 5/8" DIAGONAL METAL STUD @ 24" O.C.
EXISTING ROOF SYSTEM
PROJECT #:
ISSUED FOR:
DRAWN BY:
DRAWN ON:
CHECKED BY:
SCALE: N.T.S
REVISIONS:
SHEET TITLE:
CLIENT REVIEW
A.J.
A.J.
20151101
VANCOUVER CITY HALL
453 W. 12th AVENUE,VANCOUVER, BC
#201 - 33 East 8th AvenueVancouver, BC, V5T 1R5
Phone: 604-255-0992Fax: 604-255-1054
MAY 02, 2016
SKYLIGHT - SECTION AT REFLECTING CEILING PLAN
A109
NEW 1x6" PAINT GRADE WOOD TRIM NOTCH TO SUIT SITE CONDITIONS
NEW 3 5/8" METAL STUD FRAMED STRUCTURE.EXTEND BEYOND SKYLIGHT EDGES TO ALLOW ROOM FOR NAILING