prysmian draka - marine & offshore lv hv cables

376
Prepared by: Draka Offshore Catalog 2009 Date: 15 Jul 2009

Category:

Technology


16 download

DESCRIPTION

Prysmian Draka supplies a complete range of marine, offshore oil and gas power, control and instrumentation cables for use on oil platforms and floating oil production units (FPSO). T&D distribute an extensive range of cables from 250V to 33kV - a complete range of marine, offshore oil and gas industry cables to IEEE, UKOOA and IEC specification. The T&D and Prysmian commercial relationshipgoes back to the previous century. T&D have distributed the Prysmian Components range of cable joints, cable glands, cable cleats and high voltage cable terminations for several decades. The new relationship will now extend T&D's portfolio to embrace Prysmian Draka Offshore Marine, Oil & Gas cables. Prysmian Draka Marine Offshore Oil & Gas Cables - Overview RFOU(i) 250V S1/S5 Halogen-free, mud resistant instrumentation cable RFOU(c)250V S2/S6 Halogen-free, mud resistant instrumentation cable BFOU(i)250V S3/S7 Halogen-free, mud and fire resistant instrumentation cable BFOU(c)250V S4/S8 Halogen-free, mud and fire resistant instrumentation cable RU(i) 250V S11 Halogen-free, unarmoured, mud resistant instrumentation cable BU(i) 250V S13 Halogen-free, unarmoured, mud resistant instrumentation cable BU(c) 250V S14 Halogen-free, unarmoured, mud resistant instrumentation cable RFOU 0,6/1kV P1/P8 Halogen-free, mud resistant power cable RFOU 6/10(12)kV P3/P10 Halogen-free, mud resistant HV power cable RFOU 12/20(24)kVP19/P21 Halogen-free, mud resistant HV power cable BFOU 0,6/1kV P5/P12 Halogen-free, mud resistant, fire resistant power cable UX 1000V P15 Halogen-free, mud resistant insulated conductor RU 0,6/1kV P18 Halogen-free, unarmoured, mud resistant power cable BU 0,6/1kV P17 Halogen-free, fire resistant, unarmoured, mud resistant power cable QFCI Fire resistant optical fibre cable, halogen-free AICI Optical cable for industrial environments IFLI 250V P16 Cables for living quarter and office areas, halogen-free

TRANSCRIPT

Page 1: Prysmian Draka - Marine & Offshore LV HV Cables

Prepared by: Draka Offshore Catalog 2009

Date: 15 Jul 2009

Page 2: Prysmian Draka - Marine & Offshore LV HV Cables

CONTENTS

1Bostmarine Type LSX Power Cable Four Conductor ..............................................................................................................

3Bostmarine Type LSX Power Cable Multi-Conductor .............................................................................................................

5Bostmarine Type LSX Power Cable Three Conductor .............................................................................................................

7Bostmarine Type LSX Power Cable Two Conductor ...............................................................................................................

9Bostmarine Type LSX Signal Cable 16 AWG .....................................................................................................................

11Bostmarine Type LSX Signal Cable 18 AWG .....................................................................................................................

13Bostmarine Type LSX Signal Cable 20 AWG .....................................................................................................................

15Bostmarine Type T/N Control Cable Multi-Conductor ...........................................................................................................

17Bostmarine Type T/N Control Cable Multi-Conductor Shielded ..................................................................................................

19Bostmarine Type T/N Control Cable Shielded Triads ...........................................................................................................

21Bostmarine Type T/N Power Cable Four Conductor ..............................................................................................................

23Bostmarine Type T/N Power Cable Three Conductor .............................................................................................................

25Bostmarine Type T/N Power Cable Two Conductor ...............................................................................................................

27Bostmarine Type T/N Signal Cable 14 AWG .....................................................................................................................

29Bostmarine Type T/N Signal Cable 16 AWG .....................................................................................................................

31Bostmarine Type T/N Signal Cable 18 AWG .....................................................................................................................

33Bostmarine Type T/N Signal Cable 20 AWG .....................................................................................................................

35Bostmarine Type X Control Cable ............................................................................................................................

37Bostmarine Type X Power Cable Four Conductor ................................................................................................................

39Bostmarine Type X Power Cable Three Conductor ...............................................................................................................

41Bostmarine Type X Power Cable Two Conductor .................................................................................................................

43Bostmarine Type X Signal Cable 16 AWG .......................................................................................................................

45Bostmarine Type X Signal Cable 18 AWG .......................................................................................................................

47Bostmarine Type X Signal Cable 20 AWG .......................................................................................................................

49Bostrig 125 Type P Control 10&12AWG .........................................................................................................................

51Bostrig 125 Type P Control 12&10AWG .........................................................................................................................

53Bostrig 125 Type P Control 14AWG ............................................................................................................................

55Bostrig 125 Type P Control 14AWG AS .........................................................................................................................

57Bostrig 125 Type P Control 16AWG ............................................................................................................................

II

Page 3: Prysmian Draka - Marine & Offshore LV HV Cables

CONTENTS

59Bostrig 125 Type P Control 16AWG AS .........................................................................................................................

61Bostrig 125 Type P Control 18AWG ............................................................................................................................

63Bostrig 125 Type P Control 18AWG AS .........................................................................................................................

65Bostrig 125 Type P MR Power Cable ...........................................................................................................................

67Bostrig 125 Type P Power 1C ............................................................................................................................

69Bostrig 125 Type P Power 1C AS ............................................................................................................................

71Bostrig 125 Type P Power 2C ............................................................................................................................

73Bostrig 125 Type P Power 2C AS ............................................................................................................................

75Bostrig 125 Type P Power 3C ............................................................................................................................

77Bostrig 125 Type P Power 3C AS ............................................................................................................................

79Bostrig 125 Type P Power 4C ............................................................................................................................

81Bostrig 125 Type P Power 4C AS ............................................................................................................................

83Bostrig 125 Type P Power 5C ............................................................................................................................

85Bostrig 125 Type P Power 5C AS ............................................................................................................................

87Bostrig 125 Type P Signal Cable ............................................................................................................................

89Bostrig 125 Type P Signal Cable ............................................................................................................................

91Bostrig 125 Type P Signal IO P 16&14AWG .....................................................................................................................

93Bostrig 125 Type P Signal IO P 16&14AWG AS ..................................................................................................................

95Bostrig 125 Type P Signal IO P 20&18AWG .....................................................................................................................

97Bostrig 125 Type P Signal IO P 20&18AWG AS ..................................................................................................................

99Bostrig 125 Type P Signal IO T 18&16AWG .....................................................................................................................

101Bostrig 125 Type P Signal IO T 18&16AWG AS ..................................................................................................................

103Bostrig 125 Type P VFD 2kV ............................................................................................................................

105Bostrig MHV-15 Cable IEC 12/20 kV ...........................................................................................................................

106Bostrig MHV-15 Cable IEC 8.7/15 kV ..........................................................................................................................

107Bostrig MHV-15B Cable 100% Level ............................................................................................................................

108Bostrig MHV-15B Cable 133% Level ............................................................................................................................

109Bostrig MHV-15BS Cable IEC 12/20 kV .........................................................................................................................

110Bostrig MHV-15BS Cable IEC 8.7/15 kV ........................................................................................................................

III

Page 4: Prysmian Draka - Marine & Offshore LV HV Cables

CONTENTS

111Bostrig MHV-5 Cable ............................................................................................................................

112Bostrig MHV-5B Cable ............................................................................................................................

113Bostrig MHV-5BS Cable ............................................................................................................................

114Bostrig MHV-8 Cable IEC 3.6/6 kV ............................................................................................................................

115Bostrig MHV-8 Cable IEC 6/10 kV ............................................................................................................................

116Bostrig MHV-8B Cable 100% Level ............................................................................................................................

117Bostrig MHV-8B Cable 133% Level ............................................................................................................................

118Bostrig MHV-8BS Cable IEC 3.6/6 kV ..........................................................................................................................

119Bostrig MHV-8BS Cable IEC 6/10 kV ...........................................................................................................................

120Bostrig MHV3-15 Cable IEC 12/20 kV ..........................................................................................................................

121Bostrig MHV3-15 Cable IEC 8.7/15 kV .........................................................................................................................

122Bostrig MHV3-15B Cable 100% Level ...........................................................................................................................

123Bostrig MHV3-15B Cable 133% Level ...........................................................................................................................

124Bostrig MHV3-15BS Cable IEC 12/20 kV ........................................................................................................................

125Bostrig MHV3-15BS Cable IEC 8.7/15 kV .......................................................................................................................

126Bostrig MHV3-5 Cable ............................................................................................................................

127Bostrig MHV3-5B Cable ............................................................................................................................

128Bostrig MHV3-5BS Cable ............................................................................................................................

129Bostrig MHV3-8 Cable IEC 3.6/6 kV ...........................................................................................................................

130Bostrig MHV3-8 Cable IEC 6/10 kV ............................................................................................................................

131Bostrig MHV3-8B Cable 100% Level ............................................................................................................................

132Bostrig MHV3-8B Cable 133% Level ............................................................................................................................

133Bostrig MHV3-8BS Cable IEC 3.6/6 kV .........................................................................................................................

134Bostrig MHV3-8BS Cable IEC 6/10 kV ..........................................................................................................................

135Bostrig S611T Marine Fiber Optic Cables .....................................................................................................................

137Bostrig S670 T Marine Fiber Optic Cables ....................................................................................................................

139Datacomm 50 Ω Coaxial cable - 2.7/7.3AF ‘Low Loss’ FRNC-C ...................................................................................................

141Datacomm 50 Ω Coaxial cable - RG 213 FRNC-B .................................................................................................................

143Datacomm 50 Ω Coaxial cable - RG 214 FRNC-B .................................................................................................................

IV

Page 5: Prysmian Draka - Marine & Offshore LV HV Cables

CONTENTS

145Datacomm 50 Ω Coaxial cable - RG 214 PVC ....................................................................................................................

147Datacomm 50 Ω Coaxial cable - RG 223 FRNC-B .................................................................................................................

149Datacomm 50 Ω Coaxial cable - RG 223 PVC ....................................................................................................................

151Datacomm 6 FOILS 4x2x0.57 (AWG 23) MULTIMEDIA LSHF-FR .......................................................................................................

153Datacomm 75 Ω CATV cable - 1.0/4.8 AF FRNC-C ................................................................................................................

155Datacomm 75 Ω CATV cable - 1.6/7.3 AF FRNC ..................................................................................................................

157Datacomm 75 Ω CATV cable - Coax10 AD 10S FRNC-C .............................................................................................................

159Datacomm Analogue Audio Cable 110 O AC10 SS 26/7 10P ........................................................................................................

161Datacomm Armoured industrial cable AICI-I/O/RM-W ............................................................................................................

163Datacomm Cat. 5e SF/UTP 4x2x0.51 (AWG 24) FRNC-C ............................................................................................................

165Datacomm Cat. 7 S/FTP 4x2x0.42 (AWG 27/7) Patch LSHF ........................................................................................................

167Datacomm Cat. 7 S/FTP 4x2x0.56 (AWG 23) LSHF ................................................................................................................

169Datacomm Optical Fire Resistant Cable QFCI-I/O/RM/C-JM ......................................................................................................

171Datacomm S611T Marine Fiber Optic Cable .....................................................................................................................

173Datacomm S670T Armoured Marine Fiber Optic Cable ............................................................................................................

175Datacomm SIENOPYR-FR-PROFIBUS M-02Y(St)CHX 100V .............................................................................................................

177Datacomm ToughCat™ S/STP 4x2x0,6 (AWG 24/7) LSHF-FR .........................................................................................................

179HXXM CL2 1KV ............................................................................................................................

181HXXM CL5 1KV ............................................................................................................................

183HXXM FR CL2 1KV ............................................................................................................................

184HXXM FR CL5 1KV ............................................................................................................................

186HXXM FR Power & Control ............................................................................................................................

188HXXM(i) 1kV ............................................................................................................................

190HXXM(i) 250V ............................................................................................................................

192HXXMB 1KV CL5 armoured ............................................................................................................................

194HXXMB FR CL2 1KV armoured ............................................................................................................................

196HXXMB FR CL5 1KV armoured ............................................................................................................................

198HXXMB(c) FR 1KV armoured ............................................................................................................................

200HXXMB(i) 1kV armoured ............................................................................................................................

V

Page 6: Prysmian Draka - Marine & Offshore LV HV Cables

CONTENTS

202HXXMB(i) 250V armoured ............................................................................................................................

204HXXMB(i) FR 1kV armoured ............................................................................................................................

206HXXMB(i) FR 250V armoured ............................................................................................................................

208BFOU 1kV ............................................................................................................................

220BFOU(c) 250V ............................................................................................................................

224BFOU(i) 250V ............................................................................................................................

229BFOU-HCF(c) 250V ............................................................................................................................

231BFOU-HCF(i) 250V ............................................................................................................................

233BFOU-HCF-1kv-HF ............................................................................................................................

238BU 1kV ............................................................................................................................

242BU(c) 250V ............................................................................................................................

245BU(i) 250V ............................................................................................................................

248RFOU 12 20 24kV ............................................................................................................................

251RFOU 1kV ............................................................................................................................

263RFOU 6 10 12kV ............................................................................................................................

267RFOU(c) 250V ............................................................................................................................

271RFOU(i) 250V ............................................................................................................................

276RFOU-HCF-6_10_12kV-HF ............................................................................................................................

279RU 1kV ............................................................................................................................

285RU(c) 250V ............................................................................................................................

288RU(i) 250V ............................................................................................................................

291UX 1000V ............................................................................................................................

293Shipline BI 1KV ............................................................................................................................

296Shipline BXOI 1KV ............................................................................................................................

300Shipline BXOI 250V ............................................................................................................................

303Shipline TFOI 12KV ............................................................................................................................

305Shipline TI 1KV ............................................................................................................................

311Shipline TI(c) 1KV ............................................................................................................................

314Shipline TXOI 1KV ............................................................................................................................

VI

Page 7: Prysmian Draka - Marine & Offshore LV HV Cables

CONTENTS

320Shipline TXOI 250V ............................................................................................................................

323Shipline Plus TFXI 1KV ............................................................................................................................

329Shipline Plus TIOI(c) 250V armoured .........................................................................................................................

332Shipline TFOI 10KV amoured ............................................................................................................................

334Shipline TIOI 1KV armoured ............................................................................................................................

340BFCU 1kV ............................................................................................................................

344BFCU(c) 250V ............................................................................................................................

348BFCU(i) 250V ............................................................................................................................

353RFCU 1kV ............................................................................................................................

357RFCU(c) 250V ............................................................................................................................

361RFCU(i) 250V ............................................................................................................................

365RU 1kV ............................................................................................................................

367RU 1kV earthing cable ............................................................................................................................

This catalog represents only a partial selection of Draka Marine, Oil & Gas International wire and

cable products, based on criteria submitted when requesting the information. For a complete list

of Draka Marine, Oil & Gas International products, including specialty conversion and termination

items, visit www.DrakaMOG.com.

All products are subject to current availability. Please check with your Draka Marine, Oil & Gas

International representative.

All contents © 2007 Draka Marine, Oil & Gas International. All rights reserved.

VII

Page 8: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX POWER CABLEfour conductor / LSZH / unarmored & armored

14 AWG to 500 MCM / 600V

APPLICATIONSBOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-tions where low smoke/zero halogen flame retardant cables having excellent physical andelectrical properties are required. The insulation system has a continuous operating tem-perature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600volts. Type LSX cables are approved by ABS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTOR

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meetingspecifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-502. Thickness asshown in tables on the reverse.

3. JACKETFlame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-ered with a polyester separator tape) and complies with Type TPO thermoplastic lowsmoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kVAmerican Bureau of Shipping Approval Certificate No. B315003-X.Manufactured to Draka Cableteq USA Specifying Standard J-502

DU

SA

_LS

X05

_100

5

CustRef LSX-05

2

1

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

1

Page 9: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX POWER CABLEfour conductor / LSZH / unarmored14 AWG to 500 MCM / 600V

Insulation Jacket Cable Diameter Cable WeightTPC Part Conductor Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Size Type in • mm in • mm in • mm Lbs/mft • Kg/km

FLSXTPO-4 036338 14 • 2.1 7/24.2 0.030 • 0.76 0.045 • 1.14 0.440 • 11.2 120 • 179FLSXTPO-6 036339 12 • 3.3 7/30.5 0.030 • 0.76 0.045 • 1.14 0.485 • 12.3 164 • 244FLSXTPO-10 036340 10 • 5.3 7/38.5 0.030 • 0.76 0.060 • 1.52 0.575 • 14.6 241 • 359FLSXTPO-16 036341 8 • 8.4 7/48.6 0.045 • 1.14 0.060 • 1.52 0.730 • 18.5 382 • 568FLSXTPO-26 036342 6 • 13.3 7/61.2 0.045 • 1.14 0.060 • 1.52 0.830 • 21.1 542 • 806FLSXTPO-41 036343 4 • 21.1 7/77.2 0.045 • 1.14 0.080 • 2.03 0.990 • 25.1 824 • 1226FLSXTPO-66 036344 2 • 33.6 7/97.4 0.045 • 1.14 0.080 • 2.03 1.140 • 29.0 1205 • 1793FLSXTPO-83 036345 1 • 42.4 19/66.4 0.055 • 1.40 0.080 • 2.03 1.290 • 32.8 1500 • 2232FLSXTPO-106 036346 1/0 • 53.5 19/74.5 0.055 • 1.40 0.080 • 2.03 1.390 • 35.3 1782 • 2652FLSXTPO-133 036347 2/0 • 67.4 19/83.7 0.055 • 1.40 0.080 • 2.03 1.500 • 38.1 2220 • 3303FLSXTPO-168 036348 3/0 • 85.0 19/94.0 0.055 • 1.40 0.080 • 2.03 1.625 • 41.3 2706 • 4027FLSXTPO-212 036349 4/0 • 107.2 19/105.5 0.055 • 1.40 0.110 • 2.79 1.830 • 49.5 3444 • 5125FLSXTPO-250 036350 250 • 127.0 37/82.2 0.065 • 1.65 0.110 • 2.79 2.000 • 50.8 4002 • 5955FLSXTPO-300 036351 300 • 152.0 37/90.0 0.065 • 1.65 0.110 • 2.79 2.130 • 54.1 4680 • 6964FLSXTPO-350 036352 350 • 177.0 37/97.3 0.065 • 1.65 0.110 • 2.79 2.260 • 57.4 5464 • 8130FLSXTPO-400 036353 400 • 203.0 37/104.0 0.065 • 1.65 0.110 • 2.79 2.370 • 60.2 6140 • 9136FLSXTPO-500 036354 500 • 253.0 37/116.2 0.065 • 1.65 0.110 • 2.79 2.580 • 65.5 7560 • 11250

four conductor / LSZH / aluminum or bronze armored14 AWG to 500 MCM / 600V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Conductor Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* Size Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

FLSXTPO-4 036338 14 • 2.1 7/24.2 0.030 • 0.76 0.045 • 1.14 0.495 • 12.6 147 • 219 209 • 311FLSXTPO-6 036339 12 • 3.3 7/30.5 0.030 • 0.76 0.045 • 1.14 0.540 • 13.7 193 • 287 262 • 390FLSXTPO-10 036340 10 • 5.3 7/38.5 0.030 • 0.76 0.060 • 1.52 0.630 • 16.0 276 • 411 356 • 530FLSXTPO-16 036341 8 • 8.4 7/48.6 0.045 • 1.14 0.060 • 1.52 0.785 • 19.9 426 • 634 526 • 783FLSXTPO-26 036342 6 • 13.3 7/61.2 0.045 • 1.14 0.060 • 1.52 0.885 • 22.5 591 • 879 705 • 1049FLSXTPO-41 036343 4 • 21.1 7/77.2 0.045 • 1.14 0.080 • 2.03 1.045 • 26.5 882 • 1312 1017 • 1513FLSXTPO-66 036344 2 • 33.6 7/97.4 0.045 • 1.14 0.080 • 2.03 1.195 • 30.4 1272 • 1893 1427 • 2123FLSXTPO-83 036345 1 • 42.4 19/66.4 0.055 • 1.40 0.080 • 2.03 1.345 • 34.2 1576 • 2345 1750 • 2604FLSXTPO-106 036346 1/0 • 53.5 19/74.5 0.055 • 1.40 0.080 • 2.03 1.445 • 36.7 1863 • 2772 2051 • 3052FLSXTPO-133 036347 2/0 • 67.4 19/83.7 0.055 • 1.40 0.080 • 2.03 1.555 • 39.5 2308 • 3434 2501 • 3721FLSXTPO-168 036348 3/0 • 85.0 19/94.0 0.055 • 1.40 0.080 • 2.03 1.680 • 42.7 2801 • 4168 3020 • 4494FLSXTPO-212 036349 4/0 • 107.2 19/105.5 0.055 • 1.40 0.110 • 2.79 1.885 • 47.9 3551 • 5284 3797 • 5650FLSXTPO-250 036350 250 • 127.0 37/82.2 0.065 • 1.65 0.110 • 2.79 2.055 • 52.2 4118 • 6128 4387 • 6528FLSXTPO-300 036351 300 • 152.0 37/90.0 0.065 • 1.65 0.110 • 2.79 2.185 • 55.5 4804 • 7148 5090 • 7574FLSXTPO-350 036352 350 • 177.0 37/97.3 0.065 • 1.65 0.110 • 2.79 2.315 • 58.8 5595 • 8325 5899 • 8778FLSXTPO-400 036353 400 • 203.0 37/104.0 0.065 • 1.65 0.110 • 2.79 2.425 • 61.6 6278 • 9342 6595 • 9813FLSXTPO-500 036354 500 • 253.0 37/116.2 0.065 • 1.65 0.110 • 2.79 2.635 • 66.9 7710 • 11472 8055 • 11986

*NOTE: For aluminum armored versions, add an A (ex. 036299A). For bronze armored versions, add a B (ex. 036299B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef LSX-06Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

2

Page 10: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX CONTROL CABLEmulti-conductor / LSZH / unarmored & armored

18, 16 and 14 AWG / 600V

APPLICATIONSBOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-tions where low smOke/zero halogen flame retardant cables having excellent physical andelectrical properties are required. The insulation system has a continuous operating tem-perature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600volts. Type LSX cables are approved by ABS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTOR

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meetingspecifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-502. Thickness asshown in tables on the reverse.

3. JACKETFlame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-ered with a polyester separator tape) and complies with Type TPO thermoplastic lowsmoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kVAmerican Bureau of Shipping Approval Certificate No. B315003-X.Manufactured to Draka Cableteq USA Specifying Standard J-502

DU

SA

_LS

X07

_100

5

CustRef LSX-07

2

1

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

3

Page 11: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX CONTROL CABLEmulti-conductor / LSZH / armored & unarmored18, 16 and 14 AWG / 600V

18 AWG • 1.0 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* Conductors Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

C18LSXTPO-2 036355* 2 7/15.2 0.030 • 0.76 0.045 • 1.14 0.32 • 8.0 47 • 70 0.375 • 9.5 67 • 100 113 • 168C18LSXTPO-3 036356* 3 7/15.2 0.030 • 0.76 0.045 • 1.14 0.33 • 8.4 56 • 83 0.385 • 9.8 77 • 115 124 • 185C18LSXTPO-4 036357* 4 7/15.2 0.030 • 0.76 0.045 • 1.14 0.36 • 9.1 68 • 101 0.415 • 10.5 90 • 133 142 • 211C18LSXTPO-7 036358* 7 7/15.2 0.030 • 0.76 0.045 • 1.14 0.42 • 10.8 99 • 147 0.475 • 12.1 125 • 186 184 • 274C18LSXTPO-10 036359* 10 7/15.2 0.030 • 0.76 0.060 • 1.52 0.56 • 14.4 153 • 228 0.615 • 15.6 187 • 279 265 • 394C18LSXTPO-14 036360* 14 7/15.2 0.030 • 0.76 0.060 • 1.52 0.61 • 15.5 195 • 290 0.665 • 16.9 232 • 345 316 • 470C18LSXTPO-19 036361* 19 7/15.2 0.030 • 0.76 0.060 • 1.52 0.67 • 17.0 250 • 372 0.725 • 18.4 290 • 432 383 • 570C18LSXTPO-24 036362* 24 7/15.2 0.030 • 0.76 0.080 • 2.03 0.78 • 19.8 308 • 458 0.835 • 21.2 354 • 527 462 • 687C18LSXTPO-30 036363* 30 7/15.2 0.030 • 0.76 0.080 • 2.03 0.88 • 22.4 370 • 551 0.935 • 23.7 422 • 628 543 • 808C18LSXTPO-37 036364* 37 7/15.2 0.030 • 0.76 0.080 • 2.03 0.93 • 23.6 480 • 714 0.985 • 25.0 535 • 796 662 • 985C18LSXTPO-44 036365* 44 7/15.2 0.030 • 0.76 0.080 • 2.03 1.03 • 26.2 547 • 814 1.085 • 27.6 608 • 905 748 • 1113C18LSXTPO-61 036366* 61 7/15.2 0.030 • 0.76 0.080 • 2.03 1.10 • 27.9 696 • 1036 1.155 • 29.3 761 • 1132 910 • 1354

16 AWG • 1.3 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* Conductors Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

C16LSXTPO-2 036367* 2 7/19.2 0.030 • 0.76 0.045 • 1.14 0.34 • 8.6 57 • 85 0.395 • 10.0 78 • 116 127 • 189C16LSXTPO-3 036368* 3 7/19.2 0.030 • 0.76 0.045 • 1.14 0.36 • 9.1 71 • 106 0.415 • 10.5 93 • 138 145 • 216C16LSXTPO-4 036369* 4 7/19.2 0.030 • 0.76 0.045 • 1.14 0.39 • 9.9 87 • 129 0.445 • 11.3 111 • 165 167 • 248C16LSXTPO-7 036370* 7 7/19.2 0.030 • 0.76 0.045 • 1.14 0.46 • 11.7 129 • 192 0.515 • 13.1 157 • 234 222 • 330C16LSXTPO-10 036371* 10 7/19.2 0.030 • 0.76 0.060 • 1.52 0.61 • 15.6 197 • 293 0.665 • 16.9 234 • 348 318 • 473C16LSXTPO-14 036372* 14 7/19.2 0.030 • 0.76 0.060 • 1.52 0.67 • 16.9 255 • 379 0.725 • 18.4 295 • 439 388 • 577C16LSXTPO-19 036373* 19 7/19.2 0.030 • 0.76 0.060 • 1.52 0.73 • 18.7 328 • 488 0.785 • 19.9 372 • 553 472 • 702C16LSXTPO-24 036374* 24 7/19.2 0.030 • 0.76 0.080 • 2.03 0.90 • 22.9 444 • 661 0.955 • 24.5 497 • 740 620 • 922C16LSXTPO-30 036375* 30 7/19.2 0.030 • 0.76 0.080 • 2.03 0.95 • 24.1 529 • 787 1.055 • 26.8 585 • 870 715 • 1064C16LSXTPO-37 036376* 37 7/19.2 0.030 • 0.76 0.080 • 2.03 1.02 • 25.9 631 • 939 1.075 • 27.3 691 • 1028 830 • 1235C16LSXTPO-44 036377* 44 7/19.2 0.030 • 0.76 0.080 • 2.03 1.16 • 29.3 748 • 1113 1.215 • 30.9 816 • 1214 974 • 1449C16LSXTPO-61 036378* 61 7/19.2 0.030 • 0.76 0.080 • 2.03 1.27 • 32.4 980 • 1458 1.325 • 33.7 1054 • 1568 1227 • 1826

14 AWG • 2.1 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* Conductors Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

C14LSXTPO-2 036379* 2 7/24.2 0.030 • 0.76 0.045 • 1.14 0.37 • 9.4 72 • 107 0.425 • 10.8 95 • 141 148 • 220C14LSXTPO-3 036380* 3 7/24.2 0.030 • 0.76 0.045 • 1.14 0.39 • 9.9 92 • 137 0.445 • 11.3 116 • 173 172 • 256C14LSXTPO-4 036381* 4 7/24.2 0.030 • 0.76 0.045 • 1.14 0.42 • 10.8 114 • 170 0.475 • 12.1 140 • 208 199 • 296C14LSXTPO-7 036382* 7 7/24.2 0.030 • 0.76 0.045 • 1.14 0.51 • 12.8 173 • 257 0.565 • 14.3 204 • 304 275 • 409C14LSXTPO-10 036383* 10 7/24.2 0.030 • 0.76 0.060 • 1.52 0.68 • 17.1 261 • 388 0.735 • 18.7 302 • 449 396 • 589C14LSXTPO-14 036384* 14 7/24.2 0.030 • 0.76 0.060 • 1.52 0.73 • 18.5 342 • 509 0.785 • 19.9 386 • 574 486 • 723C14LSXTPO-19 036385* 19 7/24.2 0.030 • 0.76 0.060 • 1.52 0.81 • 20.6 444 • 661 0.865 • 22.0 492 • 732 603 • 897C14LSXTPO-24 036386* 24 7/24.2 0.030 • 0.76 0.080 • 2.03 0.99 • 25.1 593 • 882 1.045 • 26.5 651 • 967 786 • 1170C14LSXTPO-30 036387* 30 7/24.2 0.030 • 0.76 0.080 • 2.03 1.05 • 26.7 714 • 1063 1.105 • 28.1 776 • 1155 919 • 1367C14LSXTPO-37 036388* 37 7/24.2 0.030 • 0.76 0.080 • 2.03 1.13 • 28.7 856 • 1274 1.185 • 30.1 922 • 1372 1076 • 1601C14LSXTPO-44 036389* 44 7/24.2 0.030 • 0.76 0.080 • 2.03 1.27 • 32.3 1010 • 1503 1.325 • 33.7 1084 • 1613 1257 • 1870C14LSXTPO-61 036390* 61 7/24.2 0.030 • 0.76 0.080 • 2.03 1.40 • 35.4 1350 • 2009 1.455 • 37.0 1432 • 2130 1621 • 2412

*NOTE: For aluminum armored versions, add an A (ex. 036379A). For bronze armored versions, add a B (ex. 036079B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef LSX-08Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

4

Page 12: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX POWER CABLEthree conductor / LSZH / unarmored & armored

14 AWG to 1000 MCM / 600V

APPLICATIONSBOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-tions where low smoke/zero halogen flame retardant cables having excellent physical andelectrical properties are required. The insulation system has a continuous operating tem-perature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600volts. Type LSX cables are approved by ABS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTOR

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meetingspecifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-502. Thickness asshown in tables on the reverse.

3. JACKETFlame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-ered with a polyester separator tape) and complies with Type TPO thermoplastic lowsmoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kVAmerican Bureau of Shipping Approval Certificate No. B315003-X.Manufactured to Draka Cableteq USA Specifying Standard J-502

DU

SA

_LS

X03

_100

5

CustRef LSX-03

2

1

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

5

Page 13: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX POWER CABLEthree conductor / LSZH / unarmored14 AWG to 1000 MCM / 600V

Insulation Jacket Cable Diameter Cable WeightTPC Part Conductor Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Size Type in • mm in • mm in • mm Lbs/mft • Kg/km

TLSXTPO-4 036319 14 • 2.1 7/24.2 0.030 • 0.76 0.045 • 1.14 0.400 • 10.2 90 • 134TLSXTPO-6 036320 12 • 3.3 7/30.5 0.030 • 0.76 0.045 • 1.14 0.440 • 11.2 120 • 179TLSXTPO-10 036321 10 • 5.3 7/38.5 0.030 • 0.76 0.045 • 1.14 0.500 • 12.7 170 • 253TLSXTPO-16 036322 8 • 8.4 7/48.6 0.045 • 1.14 0.060 • 1.52 0.670 • 17.1 280 • 417TLSXTPO-26 036323 6 • 13.3 7/61.2 0.045 • 1.14 0.060 • 1.52 0.750 • 19.1 395 • 588TLSXTPO-41 036324 4 • 21.1 7/77.2 0.045 • 1.14 0.080 • 2.03 0.900 • 23.0 570 • 848TLSXTPO-66 036325 2 • 33.6 7/97.4 0.045 • 1.14 0.080 • 2.03 1.030 • 26.2 875 • 1302TLSXTPO-83 036326 1 • 42.4 19/66.4 0.055 • 1.40 0.080 • 2.03 1.160 • 29.5 1090 • 1622TLSXTPO-106 036327 1/0 • 53.5 19/74.5 0.055 • 1.40 0.080 • 2.03 1.255 • 31.9 1320 • 1964TLSXTPO-133 036328 2/0 • 67.4 19/83.7 0.055 • 1.40 0.080 • 2.03 1.355 • 34.4 1615 • 2403TLSXTPO-168 036329 3/0 • 85.0 19/94.0 0.055 • 1.40 0.080 • 2.03 1.470 • 37.3 1980 • 2947TLSXTPO-212 036330 4/0 • 107.2 19/105.5 0.055 • 1.40 0.080 • 2.03 1.595 • 40.5 2435 • 3624TLSXTPO-250 036331 250 • 127.0 37/82.2 0.065 • 1.65 0.110 • 2.79 1.810 • 46.0 2965 • 4412TLSXTPO-300 036332 300 • 152.0 37/90.0 0.065 • 1.65 0.110 • 2.79 1.930 • 49.0 3485 • 5186TLSXTPO-350 036333 350 • 177.0 37/97.3 0.065 • 1.65 0.110 • 2.79 2.040 • 51.8 4005 • 5960TLSXTPO-400 036334 400 • 203.0 37/104.0 0.065 • 1.65 0.110 • 2.79 2.140 • 54.4 4525 • 6734TLSXTPO-500 036335 500 • 253.0 37/116.2 0.065 • 1.65 0.110 • 2.79 2.330 • 59.2 5545 • 8252TLSXTPO-750 036336 750 • 380.0 61/110.9 0.080 • 2.03 0.140 • 3.56 2.865 • 72.8 8420 • 12530TLSXTPO-1000 036337 1000 • 507.0 61/128.0 0.080 • 2.03 0.140 • 3.56 3.200 • 81.3 11000 • 16370

three conductor / LSZH / aluminum and bronze armored14 AWG to 1000 MCM / 600V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Conductor Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* Size Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TLSXTPO-4 036319 14 • 2.1 7/24.2 0.030 • 0.76 0.045 • 1.14 0.455 • 11.3 115 • 171 171 • 254TLSXTPO-6 036320 12 • 3.3 7/30.5 0.030 • 0.76 0.045 • 1.14 0.495 • 12.6 147 • 219 209 • 311TLSXTPO-10 036321 10 • 5.3 7/38.5 0.030 • 0.76 0.045 • 1.14 0.555 • 14.1 200 • 298 270 • 402TLSXTPO-16 036322 8 • 8.4 7/48.6 0.045 • 1.14 0.060 • 1.52 0.725 • 18.4 320 • 476 413 • 615TLSXTPO-26 036323 6 • 13.3 7/61.2 0.045 • 1.14 0.060 • 1.52 0.805 • 20.4 440 • 655 543 • 808TLSXTPO-41 036324 4 • 21.1 7/77.2 0.045 • 1.14 0.080 • 2.03 0.955 • 24.3 623 • 927 746 • 1110TLSXTPO-66 036325 2 • 33.6 7/97.4 0.045 • 1.14 0.080 • 2.03 1.085 • 27.6 936 • 1393 1076 • 1601TLSXTPO-83 036326 1 • 42.4 19/66.4 0.055 • 1.40 0.080 • 2.03 1.215 • 30.9 1158 • 1732 1316 • 1958TLSXTPO-106 036327 1/0 • 53.5 19/74.5 0.055 • 1.40 0.080 • 2.03 1.310 • 33.3 1394 • 2074 1564 • 2327TLSXTPO-133 036328 2/0 • 67.4 19/83.7 0.055 • 1.40 0.080 • 2.03 1.410 • 35.8 1694 • 2521 1878 • 2794TLSXTPO-168 036329 3/0 • 85.0 19/94.0 0.055 • 1.40 0.080 • 2.03 1.525 • 38.7 2066 • 3074 2265 • 3370TLSXTPO-212 036330 4/0 • 107.2 19/105.5 0.055 • 1.40 0.080 • 2.03 1.650 • 41.9 2528 • 3762 2743 • 4082TLSXTPO-250 036331 250 • 127.0 37/82.2 0.065 • 1.65 0.110 • 2.79 1.865 • 47.4 3070 • 4568 3314 • 4931TLSXTPO-300 036332 300 • 152.0 37/90.0 0.065 • 1.65 0.110 • 2.79 1.985 • 50.4 3597 • 5352 3857 • 5739TLSXTPO-350 036333 350 • 177.0 37/97.3 0.065 • 1.65 0.110 • 2.79 2.095 • 53.2 4124 • 6137 4398 • 6544TLSXTPO-400 036334 400 • 203.0 37/104.0 0.065 • 1.65 0.110 • 2.79 2.195 • 55.8 4649 • 6918 4937 • 7346TLSXTPO-500 036335 500 • 253.0 37/116.2 0.065 • 1.65 0.110 • 2.79 2.385 • 60.6 5680 • 8452 5993 • 8918TLSXTPO-750 036336 750 • 380.0 61/110.9 0.080 • 2.03 0.140 • 3.56 2.920 • 74.2 8586 • 12776 8969 • 13346TLSXTPO-1000 036337 1000 • 507.0 61/128.0 0.080 • 2.03 0.140 • 3.56 3.255 • 82.7 11185 • 16643 11613 • 17280

*NOTE: For aluminum armored versions, add an A (ex. 036299A). For bronze armored versions, add a B (ex. 036299B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef LSX-04Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

6

Page 14: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX POWER CABLEtwo conductor / LSZH / unarmored & armored

14 AWG to 1000 MCM / 600V

APPLICATIONSBOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-tions where low smoke/zero halogen flame retardant cables having excellent physical andelectrical properties are required. The insulation system has a continuous operating tem-perature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600volts. Type LSX cables are approved by ABS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTOR

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meetingspecifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-500. Thickness asshown in tables on the reverse.

3. JACKETFlame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-ered with a polyester separator tape) and complies with Type TPO thermoplastic lowsmoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kVAmerican Bureau of Shipping Approval Certificate No. B315003-X.Manufactured to Draka Cableteq USA Specifying Standard J-500

DU

SA

_LS

X01

_100

5

CustRef LSX-01

2

1

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

7

Page 15: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX POWER CABLEtwo conductor / LSZH / unarmored14 AWG to 1000 MCM / 600V

Insulation Jacket Cable Diameter Cable WeightTPC Part Conductor Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Size Type in • mm in • mm in • mm Lbs/mft • Kg/km

DLSXTPO-4 036299 14 • 2.1 7/24.2 0.030 • 0.76 0.045 • 1.14 0.380 • 9.7 81 • 121DLSXTPO-6 036300 12 • 3.3 7/30.5 0.030 • 0.76 0.045 • 1.14 0.420 • 10.7 98 • 146DLSXTPO-10 036301 10 • 5.3 7/38.5 0.030 • 0.76 0.045 • 1.14 0.470 • 11.9 138 • 205DLSXTPO-16 036302 8 • 8.4 7/48.6 0.045 • 1.14 0.060 • 1.52 0.630 • 16.0 234 • 348DLSXTPO-26 036303 6 • 13.3 7/61.2 0.045 • 1.14 0.060 • 1.52 0.705 • 17.9 280 • 417DLSXTPO-41 036304 4 • 21.1 7/77.2 0.045 • 1.14 0.060 • 1.52 0.810 • 20.6 448 • 667DLSXTPO-66 036305 2 • 33.6 7/97.4 0.045 • 1.14 0.080 • 2.03 0.970 • 24.6 682 • 1015DLSXTPO-83 036306 1 • 42.4 19/66.4 0.055 • 1.40 0.080 • 2.03 1.090 • 27.7 835 • 1242DLSXTPO-106 036307 1/0 • 53.5 19/74.5 0.055 • 1.40 0.080 • 2.03 1.180 • 30.0 915 • 1362DLSXTPO-133 036308 2/0 • 67.4 19/83.7 0.055 • 1.40 0.080 • 2.03 1.270 • 32.3 1222 • 1818DLSXTPO-168 036309 3/0 • 85.0 19/94.0 0.055 • 1.40 0.080 • 2.03 1.380 • 35.1 1491 • 2219DLSXTPO-212 036310 4/0 • 107.2 19/105.5 0.055 • 1.40 0.080 • 2.03 1.490 • 37.8 1805 • 2686DLSXTPO-250 036311 250 • 127.0 37/82.2 0.065 • 1.65 0.080 • 2.03 1.630 • 41.4 1945 • 2894DLSXTPO-300 036312 300 • 152.0 37/90.0 0.065 • 1.65 0.110 • 2.79 1.810 • 46.0 2385 • 3549DLSXTPO-350 036313 350 • 177.0 37/97.3 0.065 • 1.65 0.110 • 2.79 1.910 • 48.5 2735 • 4070DLSXTPO-400 036314 400 • 203.0 37/104.0 0.065 • 1.65 0.110 • 2.79 2.005 • 50.9 3080 • 4584DLSXTPO-500 036315 500 • 253.0 37/116.2 0.065 • 1.65 0.110 • 2.79 2.180 • 55.4 3755 • 5588DLSXTPO-600 036316 600 • 304.0 61/99.2 0.080 • 2.03 0.110 • 2.79 2.405 • 61.1 4530 • 6741DLSXTPO-750 036317 750 • 380.0 61/110.9 0.080 • 2.03 0.110 • 2.79 2.620 • 66.5 5550 • 8259DLSXTPO-1000 036318 1000 • 507.0 61/128.0 0.080 • 2.03 0.110 • 2.79 2.995 • 76.1 7390 • 10997

two conductor / LSZH / aluminum and bronze armored14 AWG to 1000 MCM / 600V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Conductor Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* Size Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

DLSXTPO-4 036299* 14 • 2.1 7/24.2 0.030 • 0.76 0.045 • 1.14 0.435 • 11.0 104 • 155 159 • 237DLSXTPO-6 036300* 12 • 3.3 7/30.5 0.030 • 0.76 0.045 • 1.14 0.475 • 12.1 124 • 185 183 • 272DLSXTPO-10 036301* 10 • 5.3 7/38.5 0.030 • 0.76 0.045 • 1.14 0.525 • 13.3 167 • 248 233 • 347DLSXTPO-16 036302* 8 • 8.4 7/48.6 0.045 • 1.14 0.060 • 1.52 0.685 • 17.4 272 • 405 359 • 534DLSXTPO-26 036303* 6 • 13.3 7/61.2 0.045 • 1.14 0.060 • 1.52 0.760 • 19.3 322 • 479 419 • 623DLSXTPO-41 036304* 4 • 21.1 7/77.2 0.045 • 1.14 0.060 • 1.52 0.865 • 22.0 496 • 738 607 • 903DLSXTPO-66 036305* 2 • 33.6 7/97.4 0.045 • 1.14 0.080 • 2.03 1.025 • 26.0 739 • 1100 872 • 1298DLSXTPO-83 036306* 1 • 42.4 19/66.4 0.055 • 1.40 0.080 • 2.03 1.145 • 29.1 899 • 1338 1047 • 1558DLSXTPO-106 036307* 1/0 • 53.5 19/74.5 0.055 • 1.40 0.080 • 2.03 1.235 • 31.4 984 • 1464 1145 • 1704DLSXTPO-133 036308* 2/0 • 67.4 19/83.7 0.055 • 1.40 0.080 • 2.03 1.325 • 33.7 1296 • 1928 1469 • 2632DLSXTPO-168 036309* 3/0 • 85.0 19/94.0 0.055 • 1.40 0.080 • 2.03 1.435 • 36.4 1572 • 2339 1758 • 2616DLSXTPO-212 036310* 4/0 • 107.2 19/105.5 0.055 • 1.40 0.080 • 2.03 1.545 • 39.2 1892 • 2815 2093 • 3114DLSXTPO-250 036311* 250 • 127.0 37/82.2 0.065 • 1.65 0.080 • 2.03 1.685 • 42.3 2040 • 3036 2260 • 3363DLSXTPO-300 036312* 300 • 152.0 37/90.0 0.065 • 1.65 0.110 • 2.79 1.865 • 47.4 2490 • 3705 2734 • 4068DLSXTPO-350 036313* 350 • 177.0 37/97.3 0.065 • 1.65 0.110 • 2.79 1.965 • 49.9 2846 • 4235 3103 • 4617DLSXTPO-400 036314* 400 • 203.0 37/104.0 0.065 • 1.65 0.110 • 2.79 2.060 • 52.3 3197 • 4757 3466 • 5157DLSXTPO-500 036315* 500 • 253.0 37/116.2 0.065 • 1.65 0.110 • 2.79 2.235 • 56.8 3882 • 5776 4174 • 6211DLSXTPO-600 036316* 600 • 304.0 61/99.2 0.080 • 2.03 0.110 • 2.79 2.460 • 62.5 4670 • 6949 4992 • 7428DLSXTPO-750 036317* 750 • 380.0 61/110.9 0.080 • 2.03 0.110 • 2.79 2.675 • 67.9 5702 • 8485 6053 • 9007DLSXTPO-1000 036318* 1000 • 507.0 61/128.0 0.080 • 2.03 0.110 • 2.79 3.055 • 77.6 7563 • 11254 7964 • 11850

*NOTE: For aluminum armored versions, add an A (ex. 036299A). For bronze armored versions, add a B (ex. 036299B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef LSX-02Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

8

Page 16: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX SIGNAL CABLEindiv. and overall STP / LSZH / unarmored & armored

16 AWG • 1.31 mm2 / 600V

APPLICATIONSBOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-tions where low smoke/zero halogen flame retardant cables having excellent physical andelectrical properties are required. The insulation system has a continuous operating tem-perature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600volts. Type LSX cables are approved by ABS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTOR

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meetingspecifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-512. Thickness asshown in tables on the reverse.

3. PAIR SHIELDAluminum / polyester tape with tinned copper drain wire to provide 100% coverageover the twisted pair, covered with a polyester tape.

4. JACKETFlame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-ered with a polyester separator tape) and complies with Type TPO thermoplastic lowsmoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kVAmerican Bureau of Shipping Approval Certificate No. B315003-X.Manufactured to Draka Cableteq USA Specifying Standard J-512

DU

SA

_LS

X13

_100

5

CustRef LSX-13

2

1

4

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

9

Page 17: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX SIGNAL CABLEindiv. and overall STP / LSZH / unarmored16 AWG • 1.31 mm2 / 600V

Insulation Jacket Cable Diameter Cable WeightTPC Part Number of Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km

TP16(IS)LSXTPO-1 036435 1 7/19.2 0.025 • 0.64 0.045 • 1.14 0.32 • 8.1 56 • 83TP16(IS-OS)LSXTPO-2 036436 2 7/19.2 0.025 • 0.64 0.045 • 1.14 0.50 • 12.7 104 • 155TP16(IS-OS)LSXTPO-3 036437 3 7/19.2 0.025 • 0.64 0.060 • 1.52 0.56 • 14.2 153 • 228TP16(IS-OS)LSXTPO-4 036438 4 7/19.2 0.025 • 0.64 0.060 • 1.52 0.61 • 15.5 190 • 283TP16(IS-OS)LSXTPO-5 036439 5 7/19.2 0.025 • 0.64 0.060 • 1.52 0.67 • 17.0 227 • 338TP16(IS-OS)LSXTPO-6 036440 6 7/19.2 0.025 • 0.64 0.060 • 1.52 0.73 • 18.5 265 • 394TP16(IS-OS)LSXTPO-7 036441 7 7/19.2 0.025 • 0.64 0.060 • 1.52 0.73 • 18.5 295 • 439TP16(IS-OS)LSXTPO-8 036442 8 7/19.2 0.025 • 0.64 0.060 • 1.52 0.79 • 20.1 332 • 494TP16(IS-OS)LSXTPO-9 036443 9 7/19.2 0.025 • 0.64 0.080 • 2.03 0.89 • 22.6 370 • 551TP16(IS-OS)LSXTPO-10 036444 10 7/19.2 0.025 • 0.64 0.080 • 2.03 0.97 • 24.6 449 • 668TP16(IS-OS)LSXTPO-11 036445 11 7/19.2 0.025 • 0.64 0.080 • 2.03 0.99 • 25.1 487 • 724TP16(IS-OS)LSXTPO-12 036446 12 7/19.2 0.025 • 0.64 0.080 • 2.03 0.99 • 25.1 516 • 768TP16(IS-OS)LSXTPO-13 036447 13 7/19.2 0.025 • 0.64 0.080 • 2.03 1.04 • 26.4 555 • 826TP16(IS-OS)LSXTPO-14 036448 14 7/19.2 0.025 • 0.64 0.080 • 2.03 1.04 • 26.4 585 • 870TP16(IS-OS)LSXTPO-15 036449 15 7/19.2 0.025 • 0.64 0.080 • 2.03 1.10 • 27.9 621 • 924TP16(IS-OS)LSXTPO-16 036450 16 7/19.2 0.025 • 0.64 0.080 • 2.03 1.10 • 27.9 654 • 974TP16(IS-OS)LSXTPO-17 036451 17 7/19.2 0.025 • 0.64 0.080 • 2.03 1.15 • 29.2 694 • 1033TP16(IS-OS)LSXTPO-18 036452 18 7/19.2 0.025 • 0.64 0.080 • 2.03 1.15 • 29.2 724 • 1078TP16(IS-OS)LSXTPO-19 036453 19 7/19.2 0.025 • 0.64 0.080 • 2.03 1.15 • 29.2 754 • 1122TP16(IS-OS)LSXTPO-20 036454 20 7/19.2 0.025 • 0.64 0.080 • 2.03 1.21 • 30.7 790 • 1176TP16(IS-OS)LSXTPO-21 036455 21 7/19.2 0.025 • 0.64 0.080 • 2.03 1.21 • 30.7 824 • 1226TP16(IS-OS)LSXTPO-22 036456 22 7/19.2 0.025 • 0.64 0.080 • 2.03 1.28 • 32.5 865 • 1287

indiv. and overall STP / LSZH / aluminum and bronze armored16 AWG • 1.31 mm2 / 600V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TP16(IS)LSXTPO-1 036435* 1 7/19.2 0.025 • 0.64 0.045 • 1.14 0.375 • 9.5 76 • 113 122 • 182TP16(IS-OS)LSXTPO-2 036436* 2 7/19.2 0.025 • 0.64 0.045 • 1.14 0.555 • 14.1 134 • 199 204 • 304TP16(IS-OS)LSXTPO-3 036437* 3 7/19.2 0.025 • 0.64 0.060 • 1.52 0.615 • 15.6 187 • 278 265 • 394TP16(IS-OS)LSXTPO-4 036438* 4 7/19.2 0.025 • 0.64 0.060 • 1.52 0.665 • 16.9 227 • 338 311 • 463TP16(IS-OS)LSXTPO-5 036439* 5 7/19.2 0.025 • 0.64 0.060 • 1.52 0.725 • 18.4 267 • 397 360 • 534TP16(IS-OS)LSXTPO-6 036440* 6 7/19.2 0.025 • 0.64 0.060 • 1.52 0.785 • 19.9 309 • 460 409 • 609TP16(IS-OS)LSXTPO-7 036441* 7 7/19.2 0.025 • 0.64 0.060 • 1.52 0.785 • 19.9 339 • 504 439 • 653TP16(IS-OS)LSXTPO-8 036442* 8 7/19.2 0.025 • 0.64 0.060 • 1.52 0.845 • 21.4 379 • 564 487 • 725TP16(IS-OS)LSXTPO-9 036443* 9 7/19.2 0.025 • 0.64 0.080 • 2.03 0.945 • 24.0 423 • 629 544 • 809TP16(IS-OS)LSXTPO-10 036444* 10 7/19.2 0.025 • 0.64 0.080 • 2.03 1.025 • 26.0 506 • 753 639 • 951TP16(IS-OS)LSXTPO-11 036445* 11 7/19.2 0.025 • 0.64 0.080 • 2.03 1.045 • 26.5 545 • 811 680 • 1012TP16(IS-OS)LSXTPO-12 036446* 12 7/19.2 0.025 • 0.64 0.080 • 2.03 1.045 • 26.5 574 • 854 709 • 1055TP16(IS-OS)LSXTPO-13 036447* 13 7/19.2 0.025 • 0.64 0.080 • 2.03 1.095 • 27.8 616 • 917 758 • 1128TP16(IS-OS)LSXTPO-14 036448* 14 7/19.2 0.025 • 0.64 0.080 • 2.03 1.095 • 27.8 646 • 961 788 • 1173TP16(IS-OS)LSXTPO-15 036449* 15 7/19.2 0.025 • 0.64 0.080 • 2.03 1.155 • 29.3 686 • 1021 835 • 1242TP16(IS-OS)LSXTPO-16 036450* 16 7/19.2 0.025 • 0.64 0.080 • 2.03 1.155 • 29.3 719 • 1070 868 • 1292TP16(IS-OS)LSXTPO-17 036451* 17 7/19.2 0.025 • 0.64 0.080 • 2.03 1.205 • 24.2 762 • 1134 918 • 1366TP16(IS-OS)LSXTPO-18 036452* 18 7/19.2 0.025 • 0.64 0.080 • 2.03 1.205 • 24.2 792 • 1178 948 • 1411TP16(IS-OS)LSXTPO-19 036453* 19 7/19.2 0.025 • 0.64 0.080 • 2.03 1.205 • 24.2 822 • 1123 978 • 1455TP16(IS-OS)LSXTPO-20 036454* 20 7/19.2 0.025 • 0.64 0.080 • 2.03 1.265 • 32.1 861 • 1281 1025 • 1525TP16(IS-OS)LSXTPO-21 036455* 21 7/19.2 0.025 • 0.64 0.080 • 2.03 1.265 • 32.1 895 • 1332 1059 • 1576TP16(IS-OS)LSXTPO-22 036456* 22 7/19.2 0.025 • 0.64 0.080 • 2.03 1.335 • 33.9 940 • 1399 1113 • 1656

*NOTE: For aluminum armored versions, add an A (ex. 036435A). For bronze armored versions, add a B (ex. 036435B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef LSX-14Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

10

Page 18: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX SIGNAL CABLEindiv. and overall STP signal / LSZH / unarmored & armored

18 AWG • 0.82 mm2 / 600V

APPLICATIONSBOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-tions where low smoke/zero halogen flame retardant cables having excellent physical andelectrical properties are required. The insulation system has a continuous operating tem-perature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600volts. Type LSX cables are approved by ABS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTOR

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meetingspecifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-512. Thickness asshown in tables on the reverse.

3. PAIR SHIELDAluminum / polyester tape with tinned copper drain wire to provide 100% coverageover the twisted pair, covered with a polyester tape.

4. JACKETFlame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-ered with a polyester separator tape) and complies with Type TPO thermoplastic lowsmoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kVAmerican Bureau of Shipping Approval Certificate No. B315003-X.Manufactured to BIW Specifying Standard J512

DU

SA

_LS

X11

_090

5

CustRef LSX-11

2

1

4

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

11

Page 19: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX SIGNAL CABLEindiv. and overall STP signal / LSZH / unarmored18 AWG • 0.82 mm2 / 600V

Insulation Jacket Cable Diameter Cable WeightTPC Part Number of Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km

TP18(IS)LSXTPO-1 036413 1 7/15.2 0.025 • 0.64 0.045 • 1.14 0.30 • 7.6 46 • 68TP18(IS-OS)LSXTPO-2 036414 2 7/15.2 0.025 • 0.64 0.045 • 1.14 0.45 • 11.4 85 • 126TP18(IS-OS)LSXTPO-3 036415 3 7/15.2 0.025 • 0.64 0.045 • 1.14 0.48 • 12.2 109 • 162TP18(IS-OS)LSXTPO-4 036416 4 7/15.2 0.025 • 0.64 0.060 • 1.52 0.59 • 15.0 153 • 228TP18(IS-OS)LSXTPO-5 036417 5 7/15.2 0.025 • 0.64 0.060 • 1.52 0.61 • 15.5 182 • 271TP18(IS-OS)LSXTPO-6 036418 6 7/15.2 0.025 • 0.64 0.060 • 1.52 0.66 • 16.8 211 • 314TP18(IS-OS)LSXTPO-7 036419 7 7/15.2 0.025 • 0.64 0.060 • 1.52 0.66 • 16.8 232 • 346TP18(IS-OS)LSXTPO-8 036420 8 7/15.2 0.025 • 0.64 0.060 • 1.52 0.72 • 18.3 262 • 390TP18(IS-OS)LSXTPO-9 036421 9 7/15.2 0.025 • 0.64 0.060 • 1.52 0.78 • 19.8 290 • 432TP18(IS-OS)LSXTPO-10 036422 10 7/15.2 0.025 • 0.64 0.080 • 2.03 0.89 • 22.6 359 • 534TP18(IS-OS)LSXTPO-11 036423 11 7/15.2 0.025 • 0.64 0.080 • 2.03 0.91 • 23.1 346 • 516TP18(IS-OS)LSXTPO-12 036424 12 7/15.2 0.025 • 0.64 0.080 • 2.03 0.91 • 23.1 368 • 548TP18(IS-OS)LSXTPO-13 036425 13 7/15.2 0.025 • 0.64 0.080 • 2.03 0.96 • 24.4 438 • 652TP18(IS-OS)LSXTPO-14 036426 14 7/15.2 0.025 • 0.64 0.080 • 2.03 0.96 • 24.4 459 • 684TP18(IS-OS)LSXTPO-15 036427 15 7/15.2 0.025 • 0.64 0.080 • 2.03 1.01 • 25.7 490 • 729TP18(IS-OS)LSXTPO-16 036428 16 7/15.2 0.025 • 0.64 0.080 • 2.03 1.01 • 25.7 512 • 762TP18(IS-OS)LSXTPO-17 036429 17 7/15.2 0.025 • 0.64 0.080 • 2.03 1.06 • 26.9 543 • 808TP18(IS-OS)LSXTPO-18 036430 18 7/15.2 0.025 • 0.64 0.080 • 2.03 1.06 • 26.9 565 • 840TP18(IS-OS)LSXTPO-19 036431 19 7/15.2 0.025 • 0.64 0.080 • 2.03 1.06 • 26.9 586 • 872TP18(IS-OS)LSXTPO-20 036432 20 7/15.2 0.025 • 0.64 0.080 • 2.03 1.11 • 28.2 619 • 921TP18(IS-OS)LSXTPO-21 036433 21 7/15.2 0.025 • 0.64 0.080 • 2.03 1.11 • 28.2 639 • 951TP18(IS-OS)LSXTPO-22 036434 22 7/15.2 0.025 • 0.64 0.080 • 2.03 1.16 • 29.5 671 • 998

indiv. and overall STP signal / LSZH / aluminum and bronze armored18 AWG • 0.82 mm2 / 600V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TP18(IS)LSXTPO-1 036413* 1 7/15.2 0.025 • 0.64 0.045 • 1.14 0.355 • 9.0 65 • 97 108 • 161TP18(IS-OS)LSXTPO-2 036414* 2 7/15.2 0.025 • 0.64 0.045 • 1.14 0.455 • 11.6 112 • 167 176 • 262TP18(IS-OS)LSXTPO-3 036415* 3 7/15.2 0.025 • 0.64 0.045 • 1.14 0.535 • 13.6 138 • 205 206 • 307TP18(IS-OS)LSXTPO-4 036416* 4 7/15.2 0.025 • 0.64 0.060 • 1.52 0.645 • 16.4 188 • 280 271 • 403TP18(IS-OS)LSXTPO-5 036417* 5 7/15.2 0.025 • 0.64 0.060 • 1.52 0.665 • 16.9 219 • 326 303 • 451TP18(IS-OS)LSXTPO-6 036418* 6 7/15.2 0.025 • 0.64 0.060 • 1.52 0.715 • 18.2 251 • 373 342 • 509TP18(IS-OS)LSXTPO-7 036419* 7 7/15.2 0.025 • 0.64 0.060 • 1.52 0.715 • 18.2 272 • 405 363 • 540TP18(IS-OS)LSXTPO-8 036420* 8 7/15.2 0.025 • 0.64 0.060 • 1.52 0.775 • 19.7 305 • 454 404 • 601TP18(IS-OS)LSXTPO-9 036421* 9 7/15.2 0.025 • 0.64 0.060 • 1.52 0.835 • 21.2 336 • 500 444 • 661TP18(IS-OS)LSXTPO-10 036422* 10 7/15.2 0.025 • 0.64 0.080 • 2.03 0.945 • 24.0 400 • 595 524 • 780TP18(IS-OS)LSXTPO-11 036423* 11 7/15.2 0.025 • 0.64 0.080 • 2.03 0.965 • 24.5 412 • 613 533 • 793TP18(IS-OS)LSXTPO-12 036424* 12 7/15.2 0.025 • 0.64 0.080 • 2.03 0.965 • 24.5 422 • 628 546 • 812TP18(IS-OS)LSXTPO-13 036425* 13 7/15.2 0.025 • 0.64 0.080 • 2.03 1.015 • 25.8 495 • 737 626 • 931TP18(IS-OS)LSXTPO-14 036426* 14 7/15.2 0.025 • 0.64 0.080 • 2.03 1.015 • 25.8 516 • 768 647 • 963TP18(IS-OS)LSXTPO-15 036427* 15 7/15.2 0.025 • 0.64 0.080 • 2.03 1.065 • 27.1 550 • 818 687 • 1022TP18(IS-OS)LSXTPO-16 036428* 16 7/15.2 0.025 • 0.64 0.080 • 2.03 1.065 • 27.1 572 • 851 709 • 1055TP18(IS-OS)LSXTPO-17 036429* 17 7/15.2 0.025 • 0.64 0.080 • 2.03 1.115 • 28.3 605 • 900 750 • 1116TP18(IS-OS)LSXTPO-18 036430* 18 7/15.2 0.025 • 0.64 0.080 • 2.03 1.115 • 28.3 627 • 933 772 • 1149TP18(IS-OS)LSXTPO-19 036431* 19 7/15.2 0.025 • 0.64 0.080 • 2.03 1.115 • 28.3 648 • 964 793 • 1180TP18(IS-OS)LSXTPO-20 036432* 20 7/15.2 0.025 • 0.64 0.080 • 2.03 1.165 • 29.6 684 • 1018 835 • 1242TP18(IS-OS)LSXTPO-21 036433* 21 7/15.2 0.025 • 0.64 0.080 • 2.03 1.165 • 29.6 704 • 1048 855 • 1272TP18(IS-OS)LSXTPO-22 036434* 22 7/15.2 0.025 • 0.64 0.080 • 2.03 1.215 • 30.9 739 • 1100 897 • 1335

*NOTE: For aluminum armored versions, add an A (ex. 036391A). For bronze armored versions, add a B (ex. 036391B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef LSX-12Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

12

Page 20: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX SIGNAL CABLEindiv. and overall STP signal / LSZH / unarmored & armored

20 AWG • 0.52 mm2 / 300V

APPLICATIONSBOSTMARINE Type LSX 300 volt cables are suitable for use in commercial marine applica-tions where low smoke/zero halogen flame retardant cables having excellent physical andelectrical properties are required. The insulation system has a continuous operating tem-perature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 300volts. Type LSX cables are approved by ABS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTOR

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meetingspecifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-512. Thickness asshown in tables on the reverse.

3. PAIR SHIELDAluminum / polyester tape with tinned copper drain wire to provide 100% coverageover the twisted pair, covered with a polyester tape.

4. JACKETFlame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-ered with a polyester separator tape) and complies with Type TPO thermoplastic lowsmoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kVAmerican Bureau of Shipping Approval Certificate No. B315003-X.Manufactured to BIW Specifying Standard J512

DU

SA

_LS

X09

_100

5

CustRef LSX-09

2

1

4

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

13

Page 21: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE LSX SIGNAL CABLEindiv. and overall STP signal / LSZH / unarmored20 AWG • 0.52 mm2 / 300V

Insulation Jacket Cable Diameter Cable WeightTPC Part Number of Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km

TP20(IS)LSXTPO-1 036391 1 7/12.1 0.025 • 0.64 0.045 • 1.14 0.28 • 7.1 36 • 54TP20(IS-OS)LSXTPO-2 036392 2 7/12.1 0.025 • 0.64 0.045 • 1.14 0.41 • 10.4 64 • 95TP20(IS-OS)LSXTPO-3 036393 3 7/12.1 0.025 • 0.64 0.045 • 1.14 0.43 • 10.9 80 • 119TP20(IS-OS)LSXTPO-4 036394 4 7/12.1 0.025 • 0.64 0.045 • 1.14 0.48 • 12.2 97 • 144TP20(IS-OS)LSXTPO-5 036395 5 7/12.1 0.025 • 0.64 0.060 • 1.52 0.55 • 14.0 132 • 196TP20(IS-OS)LSXTPO-6 036396 6 7/12.1 0.025 • 0.64 0.060 • 1.52 0.60 • 15.2 152 • 226TP20(IS-OS)LSXTPO-7 036397 7 7/12.1 0.025 • 0.64 0.060 • 1.52 0.60 • 15.2 164 • 244TP20(IS-OS)LSXTPO-8 036398 8 7/12.1 0.025 • 0.64 0.060 • 1.52 0.65 • 16.5 185 • 275TP20(IS-OS)LSXTPO-9 036399 9 7/12.1 0.025 • 0.64 0.060 • 1.52 0.69 • 17.5 204 • 303TP20(IS-OS)LSXTPO-10 036400 10 7/12.1 0.025 • 0.64 0.060 • 1.52 0.75 • 19.1 226 • 336TP20(IS-OS)LSXTPO-11 036401 11 7/12.1 0.025 • 0.64 0.060 • 1.52 0.78 • 19.8 242 • 360TP20(IS-OS)LSXTPO-12 036402 12 7/12.1 0.025 • 0.64 0.060 • 1.52 0.78 • 19.8 256 • 381TP20(IS-OS)LSXTPO-13 036403 13 7/12.1 0.025 • 0.64 0.060 • 1.52 0.82 • 20.8 275 • 409TP20(IS-OS)LSXTPO-14 036404 14 7/12.1 0.025 • 0.64 0.060 • 1.52 0.82 • 20.8 289 • 430TP20(IS-OS)LSXTPO-15 036405 15 7/12.1 0.025 • 0.64 0.080 • 2.03 0.90 • 22.9 346 • 515TP20(IS-OS)LSXTPO-16 036406 16 7/12.1 0.025 • 0.64 0.080 • 2.03 0.90 • 22.9 359 • 534TP20(IS-OS)LSXTPO-17 036407 17 7/12.1 0.025 • 0.64 0.080 • 2.03 0.95 • 24.1 381 • 566TP20(IS-OS)LSXTPO-18 036408 18 7/12.1 0.025 • 0.64 0.080 • 2.03 0.95 • 24.1 395 • 587TP20(IS-OS)LSXTPO-19 036409 19 7/12.1 0.025 • 0.64 0.080 • 2.03 0.95 • 24.1 408 • 608TP20(IS-OS)LSXTPO-20 036410 20 7/12.1 0.025 • 0.64 0.080 • 2.03 0.99 • 25.1 429 • 638TP20(IS-OS)LSXTPO-21 036411 21 7/12.1 0.025 • 0.64 0.080 • 2.03 0.99 • 25.1 444 • 661TP20(IS-OS)LSXTPO-22 036412 22 7/12.1 0.025 • 0.64 0.080 • 2.03 1.04 • 26.4 466 • 694

indiv. and overall STP signal / LSZH / aluminum and bronze armored20 AWG • 0.52 mm2 / 300V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TP20(IS)LSXTPO-1 036391* 1 7/12.1 0.025 • 0.64 0.045 • 1.14 0.335 • 8.5 54 • 80 95 • 141TP20(IS-OS)LSXTPO-2 036392* 2 7/12.1 0.025 • 0.64 0.045 • 1.14 0.465 • 11.8 89 • 132 147 • 219TP20(IS-OS)LSXTPO-3 036393* 3 7/12.1 0.025 • 0.64 0.045 • 1.14 0.485 • 12.3 106 • 158 167 • 248TP20(IS-OS)LSXTPO-4 036394* 4 7/12.1 0.025 • 0.64 0.045 • 1.14 0.535 • 13.6 126 • 187 194 • 289TP20(IS-OS)LSXTPO-5 036395* 5 7/12.1 0.025 • 0.64 0.060 • 1.52 0.605 • 15.4 165 • 246 242 • 360TP20(IS-OS)LSXTPO-6 036396* 6 7/12.1 0.025 • 0.64 0.060 • 1.52 0.655 • 16.6 188 • 280 271 • 403TP20(IS-OS)LSXTPO-7 036397* 7 7/12.1 0.025 • 0.64 0.060 • 1.52 0.655 • 16.6 200 • 298 283 • 421TP20(IS-OS)LSXTPO-8 036398* 8 7/12.1 0.025 • 0.64 0.060 • 1.52 0.705 • 17.9 224 • 333 314 • 467TP20(IS-OS)LSXTPO-9 036399* 9 7/12.1 0.025 • 0.64 0.060 • 1.52 0.745 • 18.9 245 • 365 340 • 506TP20(IS-OS)LSXTPO-10 036400* 10 7/12.1 0.025 • 0.64 0.060 • 1.52 0.805 • 20.4 271 • 403 374 • 556TP20(IS-OS)LSXTPO-11 036401* 11 7/12.1 0.025 • 0.64 0.060 • 1.52 0.835 • 21.2 288 • 429 396 • 589TP20(IS-OS)LSXTPO-12 036402* 12 7/12.1 0.025 • 0.64 0.060 • 1.52 0.835 • 21.2 302 • 449 410 • 610TP20(IS-OS)LSXTPO-13 036403* 13 7/12.1 0.025 • 0.64 0.060 • 1.52 0.875 • 22.2 324 • 482 436 • 649TP20(IS-OS)LSXTPO-14 036404* 14 7/12.1 0.025 • 0.64 0.060 • 1.52 0.875 • 22.2 338 • 503 450 • 670TP20(IS-OS)LSXTPO-15 036405* 15 7/12.1 0.025 • 0.64 0.080 • 2.03 0.955 • 24.3 399 • 594 522 • 777TP20(IS-OS)LSXTPO-16 036406* 16 7/12.1 0.025 • 0.64 0.080 • 2.03 0.955 • 24.3 412 • 613 535 • 796TP20(IS-OS)LSXTPO-17 036407* 17 7/12.1 0.025 • 0.64 0.080 • 2.03 1.005 • 25.5 437 • 650 567 • 844 TP20(IS-OS)LSXTPO-18 036408* 18 7/12.1 0.025 • 0.64 0.080 • 2.03 1.005 • 25.5 451 • 671 581 • 869TP20(IS-OS)LSXTPO-19 036409* 19 7/12.1 0.025 • 0.64 0.080 • 2.03 1.005 • 25.5 464 • 690 594 • 884TP20(IS-OS)LSXTPO-20 036410* 20 7/12.1 0.025 • 0.64 0.080 • 2.03 1.045 • 26.5 487 • 725 622 • 926TP20(IS-OS)LSXTPO-21 036411* 21 7/12.1 0.025 • 0.64 0.080 • 2.03 1.045 • 26.5 502 • 747 637 • 948TP20(IS-OS)LSXTPO-22 036412* 22 7/12.1 0.025 • 0.64 0.080 • 2.03 1.095 • 27.8 527 • 784 669 • 995

*NOTE: For aluminum armored versions, add an A (ex. 036391A). For bronze armored versions, add a B (ex. 036391B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef LSX-10Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

14

Page 22: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N CONTROL CABLEmulti-conductor / unarmored & armored

18, 16 and 14 AWG / 600V

APPLICATIONSBOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. TypeT/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTORS

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.Insulated conductors are rated VW1.

3. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-500

DU

SA

_TN

07_0

905

CustRef TN-07

2

1

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

15

Page 23: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N CONTROL CABLEmulti-conductor / unarmored & armored18, 16 and 14 AWG / 600V

18 AWG • 1.0 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* Conductors Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

C18T/NT-2 036125* 2 7/15.2 0.019 • 0.48 0.045 • 1.14 0.28 • 7.1 35 • 52 0.33 • 8.4 53 • 79 94 • 140C18T/NT-3 036126* 3 7/15.2 0.019 • 0.48 0.045 • 1.14 0.29 • 7.4 44 • 65 0.34 • 8.6 62 • 92 105 • 156C18T/NT-4 036127* 4 7/15.2 0.019 • 0.48 0.045 • 1.14 0.31 • 7.9 53 • 79 0.36 • 9.1 72 • 107 117 • 174C18T/NT-7 029781* 7 7/15.2 0.019 • 0.48 0.045 • 1.14 0.36 • 9.1 86 • 128 0.41 • 10.4 108 • 160 160 • 238C18T/NT-10 030630* 10 7/15.2 0.019 • 0.48 0.060 • 1.52 0.45 • 11.4 117 • 174 0.50 • 12.7 144 • 214 208 • 310C18T/NT-16 350376 16 7/15.2 0.019 • 0.48 0.060 • 1.52 0.57 • 14.5 210 • 312 0.63 • 16.0 244 • 363 324 • 482C18T/NT-20 350377 20 7/15.2 0.019 • 0.48 0.060 • 1.52 0.63 • 16.0 255 • 379 0.69 • 17.5 292 • 434 379 • 564C18T/NT-24 036131* 24 7/15.2 0.019 • 0.48 0.060 • 1.52 0.65 • 16.5 262 • 390 0.70 • 17.8 301 • 448 391 • 582C18T/NT-30 036132* 30 7/15.2 0.019 • 0.48 0.060 • 1.52 0.69 • 17.5 310 • 461 0.74 • 18.8 351 • 522 446 • 664C18T/NT-37 036133* 37 7/15.2 0.019 • 0.48 0.060 • 1.52 0.74 • 18.8 372 • 554 0.79 • 20.1 416 • 619 518 • 771C18T/NT-44 036134* 44 7/15.2 0.019 • 0.48 0.060 • 1.52 0.86 • 21.8 471 • 701 0.91 • 23.1 522 • 777 640 • 952C18T/NT-61 036135* 61 7/15.2 0.019 • 0.48 0.080 • 2.03 0.95 • 24.1 612 • 911 1.00 • 25.4 668 • 994 798 • 1187

16 AWG • 1.3 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* Conductors Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

C16T/NT-2 030109* 2 7/19.2 0.019 • 0.48 0.045 • 1.14 0.30 • 7.6 49 • 73 0.35 • 8.9 68 • 101 111 • 165C16T/NT-3 036115* 3 7/19.2 0.019 • 0.48 0.045 • 1.14 0.31 • 7.9 53 • 79 0.36 • 9.1 72 • 107 117 • 174C16T/NT-4 030131* 4 7/19.2 0.019 • 0.48 0.045 • 1.14 0.34 • 8.6 72 • 107 0.39 • 9.9 93 • 138 142 • 211C16T/NT-7 030631* 7 7/19.2 0.019 • 0.48 0.045 • 1.14 0.39 • 9.9 114 • 170 0.44 • 11.2 138 • 205 194 • 289C16T/NT-10 030137* 10 7/19.2 0.019 • 0.48 0.045 • 1.14 0.50 • 12.7 159 • 237 0.55 • 14.0 189 • 281 259 • 385C16T/NT-16 350097 16 7/19.2 0.019 • 0.48 0.060 • 1.52 0.63 • 16.0 273 • 406 0.69 • 17.5 310 • 461 397 • 591C16T/NT-20 350101 20 7/19.2 0.019 • 0.48 0.060 • 1.52 0.69 • 17.5 334 • 497 0.75 • 19.1 375 • 558 470 • 699C16T/NT-24 030149* 24 7/19.2 0.019 • 0.48 0.060 • 1.52 0.72 • 18.3 358 • 533 0.77 • 19.6 401 • 597 500 • 744C16T/NT-30 030150* 30 7/19.2 0.019 • 0.48 0.060 • 1.52 0.77 • 19.6 431 • 641 0.82 • 20.8 477 • 710 583 • 868C16T/NT-37 030132* 37 7/19.2 0.019 • 0.48 0.080 • 2.03 0.87 • 22.1 556 • 827 0.92 • 23.4 608 • 905 727 • 1082C16T/NT-44 030180* 44 7/19.2 0.019 • 0.48 0.080 • 2.03 0.96 • 24.4 652 • 970 1.01 • 25.7 709 • 1055 840 • 1250C16T/NT-61 036140* 61 7/19.2 0.019 • 0.48 0.080 • 2.03 1.07 • 27.2 816 • 1214 1.12 • 28.7 879 • 1308 1025 • 1525

14 AWG • 2.1 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* Conductors Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

C14T/NT-2 036141* 2 7/24.2 0.019 • 0.48 0.045 • 1.14 0.33 • 8.4 62 • 92 0.38 • 9.7 83 • 124 130 • 193C14T/NT-3 036142* 3 7/24.2 0.019 • 0.48 0.045 • 1.14 0.35 • 8.9 81 • 121 0.40 • 10.2 103 • 153 153 • 228C14T/NT-4 036143* 4 7/24.2 0.019 • 0.48 0.045 • 1.14 0.37 • 9.4 101 • 150 0.42 • 10.7 124 • 185 177 • 263C14T/NT-7 030129* 7 7/24.2 0.019 • 0.48 0.045 • 1.14 0.44 • 11.2 157 • 234 0.49 • 12.4 184 • 274 246 • 366C14T/NT-10 030108* 10 7/24.2 0.019 • 0.48 0.060 • 1.52 0.58 • 14.7 240 • 357 0.63 • 16.0 275 • 409 356 • 530C14T/NT-16 350105 16 7/24.2 0.015 / 0.004 0.060 • 1.52 0.69 • 17.5 366 • 545 0.75 • 19.1 407 • 606 502 • 747C14T/NT-20 350111 20 7/24.2 0.015 / 0.004 0.060 • 1.52 0.74 • 18.8 451 • 671 0.80 • 20.3 495 • 737 596 • 887C14T/NT-24 030151* 24 7/24.2 0.019 • 0.48 0.060 • 1.52 0.81 • 20.6 494 • 735 0.86 • 21.8 542 • 806 653 • 972C14T/NT-30 036147* 30 7/24.2 0.019 • 0.48 0.080 • 2.03 0.90 • 22.9 639 • 951 0.95 • 24.1 692 • 1030 815 • 1213C14T/NT-37 030153* 37 7/24.2 0.019 • 0.48 0.080 • 2.03 0.96 • 24.4 762 • 1134 1.01 • 25.7 818 • 1217 950 • 1414C14T/NT-44 036148* 44 7/24.2 0.019 • 0.48 0.080 • 2.03 1.08 • 27.4 901 • 1341 1.13 • 28.7 965 • 1436 1112 • 1655C14T/NT-61 036149* 61 7/24.2 0.019 • 0.48 0.080 • 2.03 1.14 • 29.0 1210 • 1801 1.19 • 30.2 1277 • 1900 1432 • 2131

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef TN-08Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

16

Page 24: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N CONTROL CABLEmulti-conductor shielded / unarmored & armored

16 and 14 AWG / 600V

APPLICATIONSBOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. TypeT/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTORS

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.Insulated conductors are rated VW1.

3. SHIELD An aluminum/polyester tape with drain wire, 100% coverage, is applied over thecabled core.

4. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-500

DU

SA

_TN

19_0

905

CustRef TN-19

2

3

1

4

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

17

Page 25: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N CONTROL CABLEmulti-conductor shielded / unarmored & armored16 and 14 AWG / 600V

16 AWG • 1.3 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* Conductors Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

C16(OS)T/NT-2 030109* 2 7/19.2 0.019 • 0.48 0.045 • 1.14 0.31 • 7.9 58 • 86 0.37 • 9.4 77 • 115 122 • 182C16(OS)T/NT-3 036115* 3 7/19.2 0.019 • 0.48 0.045 • 1.14 0.33 • 8.4 63 • 94 0.39 • 9.9 83 • 124 130 • 193C16(OS)T/NT-4 030131* 4 7/19.2 0.019 • 0.48 0.045 • 1.14 0.35 • 8.9 82 • 122 0.41 • 10.4 103 • 153 153 • 228C16(OS)T/NT-7 030631* 7 7/19.2 0.019 • 0.48 0.045 • 1.14 0.42 • 10.7 124 • 185 0.48 • 12.2 150 • 305 209 • 311C16(OS)T/NT-10 030137* 10 7/19.2 0.019 • 0.48 0.045 • 1.14 0.55 • 14.0 169 • 251 0.58 • 14.7 200 • 418 273 • 406C16(OS)T/NT-16 350172* 16 7/19.2 0.019 • 0.48 0.060 • 1.52 0.63 • 16.0 281 • 418 0.69 • 17.5 319 • 475 406 • 604C16(OS)T/NT-20 350166* 20 7/19.2 0.019 • 0.48 0.060 • 1.52 0.70 • 17.8 343 • 510 0.76 • 19.3 385 • 573 480 • 714C16(OS)T/NT-24 030149* 24 7/19.2 0.019 • 0.48 0.060 • 1.52 0.76 • 19.3 371 • 552 0.82 • 20.8 416 • 619 521 • 775C16(OS)T/NT-30 030150* 30 7/19.2 0.019 • 0.48 0.060 • 1.52 0.81 • 20.6 444 • 661 0.87 • 22.1 492 • 1056 602 • 896C16(OS)T/NT-37 030132* 37 7/19.2 0.019 • 0.48 0.080 • 2.03 0.91 • 23.1 569 • 847 0.97 • 24.6 623 • 927 747 • 1112C16(OS)T/NT-44 030180* 44 7/19.2 0.019 • 0.48 0.080 • 2.03 1.03 • 26.2 666 • 991 1.09 • 27.7 727 • 1082 867 • 1290C16(OS)T/NT-61 036140* 61 7/19.2 0.019 • 0.48 0.080 • 2.03 1.13 • 28.7 830 • 1235 1.19 • 30.2 896 • 1333 1049 • 1561

14 AWG • 2.1 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* Conductors Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

C14(OS)T/NT-2 036141* 2 7/24.2 0.019 • 0.48 0.045 • 1.14 0.34 • 8.6 75 • 112 0.40 • 10.2 96 • 143 145 • 216C14(OS)T/NT-3 036142* 3 7/24.2 0.019 • 0.48 0.045 • 1.14 0.36 • 9.1 94 • 140 0.42 • 10.7 116 • 173 167 • 248C14(OS)T/NT-4 036143* 4 7/24.2 0.019 • 0.48 0.045 • 1.14 0.42 • 10.7 115 • 171 0.48 • 12.2 140 • 208 219 • 326C14(OS)T/NT-7 030129* 7 7/24.2 0.019 • 0.48 0.045 • 1.14 0.46 • 11.6 171 • 254 0.52 • 13.2 199 • 296 273 • 406C14(OS)T/NT-10 030108* 10 7/24.2 0.019 • 0.48 0.060 • 1.52 0.58 • 14.7 254 • 377 0.64 • 16.3 206 • 307 369 • 549C14(OS)T/NT-16 350374* 16 7/24.2 0.019 • 0.48 0.060 • 1.52 0.63 • 16.0 378 • 562 0.75 • 19.1 419 • 623 514 • 765C14(OS)T/NT-20 350375* 20 7/24.2 0.019 • 0.48 0.060 • 1.52 0.71 • 18.0 462 • 687 0.82 • 20.8 507 • 754 612 • 911C14(OS)T/NT-24 030151* 24 7/24.2 0.019 • 0.48 0.060 • 1.52 0.84 • 21.3 510 • 759 0.90 • 22.9 560 • 833 675 • 1004C14(OS)T/NT-30 036147* 30 7/24.2 0.019 • 0.48 0.080 • 2.03 0.93 • 23.6 655 • 975 0.99 • 25.1 710 • 1056 837 • 1245C14(OS)T/NT-37 030153* 37 7/24.2 0.019 • 0.48 0.080 • 2.03 1.00 • 25.4 778 • 1158 1.06 • 26.9 837 • 1245 972 • 1446C14(OS)T/NT-44 036148* 44 7/24.2 0.019 • 0.48 0.080 • 2.03 1.13 • 28.7 917 • 1364 1.19 • 30.2 983 • 1463 1137 • 1692C14(OS)T/NT-61 036149* 61 7/24.2 0.019 • 0.48 0.080 • 2.03 1.18 • 30.0 1226 • 1824 1.24 • 31.5 1295 • 1927 1456 • 2167

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef TN-20Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

18

Page 26: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N CONTROL CABLEindiv. & overall shielded triads / unarmored & armored

18, 16 and 14 AWG / 600V

APPLICATIONSBOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. TypeT/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTORS

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.Insulated conductors are rated VW1.

3. TRIAD SHIELDAluminum / polyester tape with tinned copper drain wire to provide 100% coverageover the twisted pair, covered with a polyester tape.

4. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-510

DU

SA

_TN

17_1

005

CustRef TN-17

2

1

4

3

DrakaMarine Shipboard Cables

ISO9001QSC3497

DRAKA-USA

DR

AK

AM

OG

BO

STM

AR

INE

19

Page 27: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N CONTROL CABLEindiv. & overall shielded twisted triad / unarmored & armored18, 16 and 14 AWG / 600V

18 AWG • 1.0 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* triads Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TT18(IS-OS)T/NT-1 350370 1 7/15.2 0.019 • 0.48 0.045 • 1.14 0.31 • 7.9 56 • 83 0.37 • 9.4 75 • 112 119 • 177TT18(IS-OS)T/NT-3 350371 3 7/15.2 0.019 • 0.48 0.060 • 1.52 0.59 • 15.0 174 • 259 0.65 • 16.5 209 • 311 291 • 433TT18(IS-OS)T/NT-6 350372 6 7/15.2 0.019 • 0.48 0.060 • 1.52 0.76 • 19.3 294 • 437 0.82 • 20.8 339 • 504 444 • 661TT18(IS-OS)T/NT-12350373 12 7/15.2 0.019 • 0.48 0.080 • 2.03 1.05 • 26.7 567 • 844 1.11 • 28.2 629 • 936 772 • 1149

16 AWG • 1.3 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* triads Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TT16(IS-OS)T/NT-1 350366 1 7/19.2 0.019 • 0.48 0.045 • 1.14 0.33 • 8.4 70 • 104 0.39 • 9.9 91 • 135 138 • 205TT16(IS-OS)T/NT-3 350367 3 7/19.2 0.019 • 0.48 0.060 • 1.52 0.64 • 16.3 222 • 330 0.70 • 17.8 260 • 387 349 • 519TT16(IS-OS)T/NT-6 350368 6 7/19.2 0.019 • 0.48 0.060 • 1.52 0.84 • 21.3 380 • 565 0.90 • 22.9 430 • 640 555 • 826TT16(IS-OS)T/NT-12350369 12 7/19.2 0.019 • 0.48 0.080 • 2.03 1.15 • 29.2 683 • 1016 1.21 • 30.7 751 • 1117 907 • 1350

14 AWG • 2.1 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* triads Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TT14(IS-OS)T/NT-1 350362 1 7/24.2 0.019 • 0.48 0.045 • 1.14 0.36 • 9.1 93 • 138 0.42 • 10.7 115 • 171 166 • 247TT14(IS-OS)T/NT-3 350363 3 7/24.2 0.019 • 0.48 0.060 • 1.52 0.70 • 17.8 294 • 437 0.76 • 19.3 336 • 500 431 • 641TT14(IS-OS)T/NT-6 350364 6 7/24.2 0.019 • 0.48 0.060 • 1.52 0.96 • 24.4 558 • 830 1.02 • 25.9 614 • 914 745 • 1109TT14(IS-OS)T/NT-12350365 12 7/24.2 0.019 • 0.48 0.080 • 2.03 1.26 • 32.0 1007 • 1498 1.32 • 33.5 1081 • 1609 1251 • 1861

*NOTE: For aluminum armored versions, add an A (ex. 350356A). For bronze armored versions, add a B (ex. 350356B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef TN-18Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

20

Page 28: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N POWER CABLEfour conductor power distribution / unarmored & armored

14 AWG to 750 MCM / 600V

APPLICATIONSBOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. TypeT/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTORS

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.Insulated conductors are rated Vw1.

3. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-500

DU

SA

_TN

05_0

905

CustRef TN-05

2

1

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

21

Page 29: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N POWER CABLEfour conductor power distribution / unarmored14 AWG to 750 MCM / 600V

PVC/Nylon Jacket Unarmored UnarmoredTPC Part Conductor Size Stranding Insulation Thickness Thickness Cable Diameter Cable WeightCable Type Number AWG/MCM • mm2 Type in • mm in • mm in • mm Lbs/mft • Kg/km

FT/NT-4 030104 14 • 2.1 7/24.2 0.015/0.38 • 0.004/0.10 0.045 • 1.14 0.39 • 9.9 151 • 225FT/NT-6 030130 12 • 3.3 7/30.5 0.015/0.38 • 0.004/0.10 0.045 • 1.14 0.43 • 10.9 225 • 335FT/NT-10 030128 10 • 5.3 7/38.5 0.020/0.51 • 0.004/0.10 0.045 • 1.14 0.51 • 13.0 366 • 545FT/NT-16 030135 8 • 8.4 7/48.6 0.030/0.76 • 0.005//0.13 0.060 • 1.52 0.66 • 16.8 536 • 798FT/NT-26 030134 6 • 13.3 7/61.2 0.030/0.76 • 0.005/0.13 0.060 • 1.52 0.77 • 19.6 878 • 1307FT/NT-41 030133 4 • 21.1 7/77.2 0.040/1.02 • 0.006/0.15 0.080 • 2.03 0.99 • 25.1 1268 • 1887FT/NT-66 030179 2 • 33.6 7/97.4 0.040//1.02 • 0.006/0.15 0.080 • 2.03 1.13 • 28.7 1598 • 2378FT/NT-83 036114 1 • 42.4 19/66.4 0.050/1.27 • 0.007/0.18 0.080 • 2.03 1.27 • 32.3 1924 • 2863FT/NT-106 036115 1/0 • 53.5 19/74.5 0.050/1.27 • 0.007/0.18 0.080 • 2.03 1.38 • 35.1 2374 • 3533FT/NT-133 036116 2/0 • 67.4 19/83.7 0.050/1.27 • 0.007/0.18 0.080 • 2.03 1.49 • 37.8 2569 • 3823FT/NT-168 036117 3/0 • 85.0 19/94.0 0.050/1.27 • 0.007/0.18 0.080 • 2.03 1.61 • 40.9 2850 • 4241FT/NT-212 030177 4/0 • 107.2 19/105.5 0.050/1.27 • 0.007/0.18 0.110 • 2.79 1.82 • 46.2 3650 • 5432FT/NT-250 036118 250 • 127.0 37/82.2 0.060/1.52 • 0.008/0.20 0.110 • 2.79 1.98 • 50.3 4319 • 6427FT/NT-300 036119 300 • 152.0 37/90.0 0.060/1.52 • 0.008/0.20 0.110 • 2.79 2.11 • 53.6 5051 • 7517FT/NT-350 036120 350 • 177.0 37/97.3 0.060/1.52 • 0.008/0.20 0.110 • 2.79 2.34 • 59.4 5866 • 8730FT/NT-400 036121 400 • 203.0 37/104.0 0.060/1.52 • 0.008/0.20 0.110 • 2.79 2.46 • 62.5 6623 • 9856FT/NT-500 036122 500 • 253.0 37/116.2 0.060/1.52 • 0.008/0.20 0.110 • 2.79 2.56 • 65.0 8086 • 12033FT/NT-600 036123 600 • 304.0 61/99.2 0.070/1.78 • 0.009/0.23 0.140 • 3.56 2.87 • 72.9 9657 • 14371FT/NT-750 036124 750 • 380.0 61/110.9 0.070/1.78 • 0.009/0.23 0.140 • 3.56 3.11 • 79.0 11949 • 17782

four conductor power distribution / aluminum or bronze armored14 AWG to 750 MCM / 600V

PVC/Nylon Jacket Armored Aluminum arm. Bronze arm.TPC Part Conductor Size Stranding Insulation Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* AWG/MCM • mm2 Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

FT/NT-4 030104* 14 • 2.1 7/24.2 0.015/0.38 • 0.004/0.10 0.045 • 1.14 0.44 • 11.2 174 • 259 229 • 341FT/NT-6 030130* 12 • 3.3 7/30.5 0.015/0.38 • 0.004/0.10 0.045 • 1.14 0.48 • 12.2 251 • 373 310 • 461FT/NT-10 030128* 10 • 5.3 7/38.5 0.020/0.51 • 0.004/0.10 0.045 • 1.14 0.56 • 14.2 396 • 589 466 • 693FT/NT-16 030135* 8 • 8.4 7/48.6 0.030/0.76 • 0.005//0.13 0.060 • 1.52 0.71 • 18.1 575 • 856 664 • 988FT/NT-26 030134* 6 • 13.3 7/61.2 0.030/0.76 • 0.005/0.13 0.060 • 1.52 0.82 • 20.9 923 • 1373 1026 • 1527FT/NT-41 030133* 4 • 21.1 7/77.2 0.040/1.02 • 0.006/0.15 0.080 • 2.03 1.04 • 26.4 1325 • 1971 1457 • 2168FT/NT-66 030179* 2 • 33.6 7/97.4 0.040//1.02 • 0.006/0.15 0.080 • 2.03 1.18 • 30.0 1663 • 2475 1813 • 2698FT/NT-83 036114* 1 • 42.4 19/66.4 0.050/1.27 • 0.007/0.18 0.080 • 2.03 1.32 • 33.8 1997 • 2972 2165 • 3222FT/NT-106 036115* 1/0 • 53.5 19/74.5 0.050/1.27 • 0.007/0.18 0.080 • 2.03 1.43 • 36.3 2453 • 3650 2635 • 3921FT/NT-133 036116* 2/0 • 67.4 19/83.7 0.050/1.27 • 0.007/0.18 0.080 • 2.03 1.54 • 39.1 2654 • 3949 2850 • 4241FT/NT-168 036117* 3/0 • 85.0 19/94.0 0.050/1.27 • 0.007/0.18 0.080 • 2.03 1.66 • 42.2 2942 • 4378 3154 • 4693FT/NT-212 030177* 4/0 • 107.2 19/105.5 0.050/1.27 • 0.007/0.18 0.110 • 2.79 1.87 • 47.5 3753 • 5584 3993 • 5942FT/NT-250 036118* 250 • 127.0 37/82.2 0.060/1.52 • 0.008/0.20 0.110 • 2.79 2.03 • 51.6 4431 • 6593 4691 • 6980FT/NT-300 036119* 300 • 152.0 37/90.0 0.060/1.52 • 0.008/0.20 0.110 • 2.79 2.16 • 54.9 5171 • 7694 5447 • 8105FT/NT-350 036120* 350 • 177.0 37/97.3 0.060/1.52 • 0.008/0.20 0.110 • 2.79 2.39 • 60.7 5999 • 8927 6305 • 9382FT/NT-400 036121* 400 • 203.0 37/104.0 0.060/1.52 • 0.008/0.20 0.110 • 2.79 2.51 • 63.8 6762 • 10062 7084 • 10541FT/NT-500 036122* 500 • 253.0 37/116.2 0.060/1.52 • 0.008/0.20 0.110 • 2.79 2.61 • 66.3 8235 • 12254 8566 • 12746FT/NT-600 036123* 600 • 304.0 61/99.2 0.070/1.78 • 0.009/0.23 0.140 • 3.56 2.92 • 74.2 9819 • 14611 10194 • 15169FT/NT-750 036124* 750 • 380.0 61/110.9 0.070/1.78 • 0.009/0.23 0.140 • 3.56 3.16 • 80.3 12125 • 18042 12531 • 18646

*NOTE: For aluminum armored versions, add an A (ex. 030104A). For bronze armored versions, add a B (ex. 030104B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef TN-06Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

22

Page 30: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N POWER CABLEthree conductor power distribution / unarmored & armored

14 AWG to 750 MCM / 600V

APPLICATIONSBOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. TypeT/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTORS

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.Insulated conductors are rated VW1.

3. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-500

DU

SA

_TN

03_1

005

CustRef TN-03

2

1

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

23

Page 31: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N POWER CABLEthree conductor power distribution / unarmored & armored14 AWG to 750 MCM / 600V

PVC/Nylon Jacket Unarmored UnarmoredTPC Part Conductor Size Stranding Insulation Thickness Thickness Cable Diameter Cable WeightCable Type Number AWG/MCM • mm2 Type in • mm in • mm in • mm Lbs/mft • Kg/km

TT/NT-4 030101 14 • 2.1 7/24.2 0.015/0.004 • 0.38/0.10 0.045 • 1.14 0.35 • 8.9 86 • 128TT/NT-6 030102 12 • 3.3 7/30.5 0.015/0.004 • 0.38/0.10 0.045 • 1.14 0.39 • 9.9 120 • 179TT/NT-10 030107 10 • 5.3 7/38.5 0.020/0.004 • 0.51/0.10 0.045 • 1.14 0.46 • 11.7 171 • 254TT/NT-16 030106 8 • 8.4 7/48.6 0.030/0.005 • 0.76/0.13 0.060 • 1.52 0.61 • 15.5 301 • 448TT/NT-26 030105 6 • 13.3 7/61.2 0.030/0.005 • 0.76/0.13 0.060 • 1.52 0.69 • 17.5 406 • 604TT/NT-41 030110 4 • 21.1 7/77.2 0.040/0.006 •1.02/0.15 0.080 • 2.03 0.84 • 21.3 664 • 988TT/NT-66 030112 2 • 33.6 7/97.4 0.040/0.006 •1.02/0.15 0.080 • 2.03 1.02 • 25.9 980 • 1458TT/NT-83 036102 1 • 42.4 19/66.4 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.16 • 29.5 1228 • 1827TT/NT-106 030178 1/0 • 53.5 19/74.5 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.24 • 31.5 1557 • 2317TT/NT-133 036103 2/0 • 67.4 19/83.7 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.36 • 34.5 1828 • 2720TT/NT-168 036104 3/0 • 85.0 19/94.0 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.45 • 36.8 2244 • 3339TT/NT-212 036105 4/0 • 107.2 19/105.5 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.59 • 40.4 2773 • 4127TT/NT-250 036106 250 • 127.0 37/82.2 0.060/0.008 • 1.52/0.20 0.110 • 2.79 1.80 • 45.7 3360 • 5000TT/NT-300 036107 300 • 152.0 37/90.0 0.060/0.008 • 1.52/0.20 0.110 • 2.79 1.91 • 48.5 3920 • 5834 TT/NT-350 036108 350 • 177.0 37/97.3 0.060/0.008 • 1.52/0.20 0.110 • 2.79 2.05 • 52.1 4550 • 6771TT/NT-400 036109 400 • 203.0 37/104.0 0.060/0.008 • 1.52/0.20 0.110 • 2.79 2.22 • 56.4 5133 • 7639 TT/NT-500 036110 500 • 253.0 37/116.2 0.060/0.008 • 1.52/0.20 0.110 • 2.79 2.45 • 62.2 6472 • 9631TT/NT-600 036111 600 • 304.0 61/99.2 0.070/0.009 • 1.78/0.22 0.110 • 2.79 2.52 • 64.0 7375 • 10975 TT/NT-750 036112 750 • 380.0 61/110.9 0.070/0.009 • 1.78/0.22 0.110 • 2.79 2.83 • 71.9 9200 • 13691

three conductor power distribution / aluminum or bronze armored14 AWG to 750 MCM / 600V

PVC/Nylon Jacket Armored Aluminum arm. Bronze arm.TPC Part Conductor Size Stranding Insulation Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* AWG/MCM • mm2 Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TT/NT-4 030101* 14 • 2.1 7/24.2 0.015/0.004 • 0.38/0.10 0.045 • 1.14 0.38 • 9.7 107 • 159 156 • 232TT/NT-6 030102* 12 • 3.3 7/30.5 0.015/0.004 • 0.38/0.10 0.045 • 1.14 0.44 • 11.2 143 • 213 198 • 295TT/NT-10 030107* 10 • 5.3 7/38.5 0.020/0.004 • 0.51/0.10 0.045 • 1.14 0.51 • 13.0 198 • 295 262 • 390TT/NT-16 030106* 8 • 8.4 7/48.6 0.030/0.005 • 0.76/0.13 0.060 • 1.52 0.66 • 16.8 337 • 501 419 • 623TT/NT-26 030105* 6 • 13.3 7/61.2 0.030/0.005 • 0.76/0.13 0.060 • 1.52 0.74 • 18.8 446 • 664 539 • 802TT/NT-41 030110* 4 • 21.1 7/77.2 0.040/0.006 •1.02/0.15 0.080 • 2.03 0.89 • 22.6 713 • 1061 825 • 1228TT/NT-66 030112* 2 • 33.6 7/97.4 0.040/0.006 •1.02/0.15 0.080 • 2.03 1.07 • 27.2 1039 • 1626 1174 • 1747TT/NT-83 036102* 1 • 42.4 19/66.4 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.21 • 30.8 1295 • 1927 1448 • 2155TT/NT-106 030178* 1/0 • 53.5 19/74.5 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.29 • 32.8 1628 • 2422 1792 • 2666TT/NT-133 036103* 2/0 • 67.4 19/83.7 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.41 • 35.8 1906 • 2836 2085 • 3102TT/NT-168 036104* 3/0 • 85.0 19/94.0 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.50 • 38.1 2327 • 3463 2518 • 3747TT/NT-212 036105* 4/0 • 107.2 19/105.5 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.64 • 41.7 2864 • 4262 3073 • 4573TT/NT-250 036106* 250 • 127.0 37/82.2 0.060/0.008 • 1.52/0.20 0.110 • 2.79 1.85 • 47.0 3462 • 5151 3699 • 5504TT/NT-300 036107* 300 • 152.0 37/90.0 0.060/0.008 • 1.52/0.20 0.110 • 2.79 1.96 • 49.8 4029 • 5995 4280 • 6369TT/NT-350 036108* 350 • 177.0 37/97.3 0.060/0.008 • 1.52/0.20 0.110 • 2.79 2.10 • 53.4 4666 • 6943 4935 • 7343TT/NT-400 036109* 400 • 203.0 37/104.0 0.060/0.008 • 1.52/0.20 0.110 • 2.79 2.27 • 57.7 5259 • 7825 5550 • 8258TT/NT-500 036110* 500 • 253.0 37/116.2 0.060/0.008 • 1.52/0.20 0.110 • 2.79 2.50 • 63.5 6611 • 9837 6932 • 10315TT/NT-600 036111* 600 • 304.0 61/99.2 0.070/0.009 • 1.78/0.22 0.110 • 2.79 2.57 • 65.3 7518 • 11187 7847 • 11676TT/NT-750 036112* 750 • 380.0 61/110.9 0.070/0.009 • 1.78/0.22 0.110 • 2.79 2.88 • 73.2 9360 • 13928 9730 • 14478

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef TN-04Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

24

Page 32: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N POWER CABLEtwo conductor power distribution / unarmored & armored

14 AWG to 500 MCM / 600V

APPLICATIONSBOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. TypeT/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTORS

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.Insulated conductors are rated VW1.

3. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-500

DU

SA

_TN

01_1

005

CustRef TN-01

2

1

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

25

Page 33: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N POWER CABLEtwo conductor power distribution / unarmored & armored14 AWG to 500 MCM / 600V

PVC/Nylon Jacket Unarmored UnarmoredTPC Part Conductor Size Stranding Insulation Thickness Thickness Cable Diameter Cable WeightCable Type Number AWG/MCM • mm2 Type in • mm in • mm in • mm Lbs/mft • Kg/km

DT/NT-4 030103 14 • 2.1 7/24.2 0.015/0.004 • 0.38/0.10 0.045 • 1.14 0.33 • 8.4 66 • 98DT/NT-6 030123 12 • 3.3 7/30.5 0.015/0.004 • 0.38/0.10 0.045 • 1.14 0.37 • 9.4 88 • 131DT/NT-10 030114 10 • 5.3 7/38.5 0.020/0.004 • 0.51/0.10 0.045 • 1.14 0.43 • 10.9 133 • 198DT/NT-16 030138 8 • 8.4 7/48.6 0.030/0.005 • 0.76/0.13 0.060 • 1.52 0.58 • 14.7 216 • 321DT/NT-26 030139 6 • 13.3 7/61.2 0.030/0.005 • 0.76/0.13 0.060 • 1.52 0.65 • 16.5 311 • 463DT/NT-41 030182 4 • 21.1 7/77.2 0.040/0.006 • 1.02/0.15 0.060 • 1.52 0.80 • 20.3 479 • 713DT/NT-66 036090 2 • 33.6 7/97.4 0.040/0.006 • 1.02/0.15 0.080 • 2.03 0.97 • 24.6 727 • 1082DT/NT-83 036091 1 • 42.4 19/66.4 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.00 • 25.4 933 • 1388DT/NT-106 036092 1/0 • 53.5 19/74.5 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.18 • 30.0 1110 • 1652DT/NT-133 036093 2/0 • 67.4 19/83.7 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.27 • 32.3 1323 • 1969DT/NT-168 036094 3/0 • 85.0 19/94.0 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.38 • 35.1 1602 • 2384DT/NT-212 036095 4/0 • 107.2 19/105.5 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.56 • 39.6 2122 • 3158DT/NT-250 036096 250 • 127.0 37/82.2 0.060/0.080 • 1.52/2.03 0.080 • 2.03 1.62 • 41.1 2337 • 3478DT/NT-300 036097 300 • 152.0 37/90.0 0.060/0.080 • 1.52/2.03 0.110 • 2.79 1.80 • 45.7 2851 • 4243DT/NT-350 036049 350 • 177.0 37/97.3 0.060/0.080 • 1.52/2.03 0.110 • 2.79 1.90 • 48.3 3303 • 4915DT/NT-400 036098 400 • 203.0 37/104.0 0.060/0.080 • 1.52/2.03 0.110 • 2.79 2.08 • 52.8 3662 • 5450DT/NT-500 036099 500 • 253.0 37/116.2 0.060/0.080 • 1.52/2.03 0.110 • 2.79 2.17 • 55.1 4497 • 6692

two conductor power distribution / aluminum or bronze armored14 AWG to 750 MCM / 600V

PVC/Nylon Jacket Armored Aluminum arm. Bronze arm.TPC Part Conductor Size Stranding Insulation Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* AWG/MCM • mm2 Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

DT/NT-4 030103* 14 • 2.1 7/24.2 0.015/0.004 • 0.38/0.10 0.045 • 1.14 0.38 • 9.7 86 • 128 132 • 196DT/NT-6 030123* 12 • 3.3 7/30.5 0.015/0.004 • 0.38/0.10 0.045 • 1.14 0.42 • 10.7 110 • 164 162 • 240DT/NT-10 030114* 10 • 5.3 7/38.5 0.020/0.004 • 0.51/0.10 0.045 • 1.14 0.48 • 12.5 159 • 237 218 • 324DT/NT-16 030138* 8 • 8.4 7/48.6 0.030/0.005 • 0.76/0.13 0.060 • 1.52 0.63 • 16.0 250 • 372 329 • 490DT/NT-26 030139* 6 • 13.3 7/61.2 0.030/0.005 • 0.76/0.13 0.060 • 1.52 0.70 • 17.8 351 • 522 437 • 650DT/NT-41 030182* 4 • 21.1 7/77.2 0.040/0.006 • 1.02/0.15 0.060 • 1.52 0.85 • 21.6 530 • 789 633 • 942DT/NT-66 036090* 2 • 33.6 7/97.4 0.040/0.006 • 1.02/0.15 0.080 • 2.03 1.02 • 25.9 791 • 1177 912 • 1357DT/NT-83 036091* 1 • 42.4 19/66.4 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.05 • 26.7 991 • 1475 1124 • 1673DT/NT-106 036092* 1/0 • 53.5 19/74.5 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.23 • 31.3 1178 • 1753 1334 • 1985DT/NT-133 036093* 2/0 • 67.4 19/83.7 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.32 • 33.6 1396 • 2077 1564 • 2327DT/NT-168 036094* 3/0 • 85.0 19/94.0 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.43 • 36.3 1681 • 2501 1863 • 2772DT/NT-212 036095* 4/0 • 107.2 19/105.5 0.050/0.007 • 1.27/0.18 0.080 • 2.03 1.61 • 40.9 2211 • 3290 2416 • 3595DT/NT-250 036096* 250 • 127.0 37/82.2 0.060/0.080 • 1.52/2.03 0.080 • 2.03 1.67 • 42.4 2429 • 3614 2643 • 3933DT/NT-300 036097* 300 • 152.0 37/90.0 0.060/0.080 • 1.52/2.03 0.110 • 2.79 1.85 • 47.0 2953 • 4394 3190 • 4747DT/NT-350 036049* 350 • 177.0 37/97.3 0.060/0.080 • 1.52/2.03 0.110 • 2.79 1.95 • 49.6 3411 • 5076 3660 • 5446DT/NT-400 036098* 400 • 203.0 37/104.0 0.060/0.080 • 1.52/2.03 0.110 • 2.79 2.13 • 54.1 3780 • 5625 4053 • 6031DT/NT-500 036099* 500 • 253.0 37/116.2 0.060/0.080 • 1.52/2.03 0.110 • 2.79 2.22 • 56.4 4620 • 6875 4904 • 7297

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef TN-02Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

26

Page 34: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored & armored

14 AWG • 2.1 mm2 / 600V

APPLICATIONSBOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. TypeT/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTORS

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.Insulated conductors are rated VW1.

3. PAIR SHIELDAluminum / polyester tape with tinned copper drain wire to provide 100% coverageover the twisted pair, covered with a polyester tape.

4. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-510

DU

SA

_TN

15_1

005

CustRef TN-15

2

1

4

3

DrakaMarine Shipboard Cables

ISO9001QSC3497

DRAKA-USA

DR

AK

AM

OG

BO

STM

AR

INE

27

Page 35: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored & armored14 AWG • 2.1 mm2 / 600V

Insulation Jacket Cable Diameter Cable WeightTPC Part Number of Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km

TP14(IS-OS)T/NT-1 350356 1 7/24.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.340 • 8.6 73 • 109TP14(IS-OS)T/NT-2 350357 2 7/24.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.575 • 14.6 175 • 260TP14(IS-OS)T/NT-3 350358 3 7/24.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.605 • 15.4 228 • 339TP14(IS-OS)T/NT-4 350360 4 7/24.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.665 • 16.9 282 • 420TP14(IS-OS)T/NT-6 350361 6 7/24.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.790 • 20.1 392 • 583

indiv. & overall shielded twisted pair / aluminum or bronze armored14 AWG • 2.1 mm2 / 600V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TP14(IS-OS)T/NT-1 350356* 1 7/24.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.400 • 10.2 94 • 140 143 • 213TP14(IS-OS)T/NT-2 350357* 2 7/24.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.635 • 16.1 210 • 312 290 • 432TP14(IS-OS)T/NT-3 350358* 3 7/24.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.665 • 16.9 264 • 393 348 • 518TP14(IS-OS)T/NT-4 350360* 4 7/24.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.725 • 18.4 322 • 479 414 • 616TP14(IS-OS)T/NT-6 350361* 6 7/24.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.850 • 21.6 439 • 653 547 • 814

*NOTE: For aluminum armored versions, add an A (ex. 350356A). For bronze armored versions, add a B (ex. 350356B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef TN-16Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

28

Page 36: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored & armored

16 AWG • 1.3 mm2 / 600V

APPLICATIONSBOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. TypeT/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTORS

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.Insulated conductors are rated VW1.

3. PAIR SHIELDAluminum / polyester tape with tinned copper drain wire to provide 100% coverageover the twisted pair, covered with a polyester tape.

4. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-510

DU

SA

_TN

13_1

005

CustRef TN-13

2

1

4

3

DrakaMarine Shipboard Cables

ISO9001QSC3497

DRAKA-USA

DR

AK

AM

OG

BO

STM

AR

INE

29

Page 37: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored & armored16 AWG • 1.3 mm2 / 600V

Insulation Jacket Cable Diameter Cable WeightTPC Part Number of Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km

TP16(IS)T/NT-1 030160 1 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.29 • 7.4 49 • 72TP16(IS-OS)T/NT-2 030162 2 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.43 • 11.0 58 • 86TP16(IS-OS)T/NT-3 036194 3 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.46 • 11.7 124 • 184TP16(IS-OS)T/NT-4 030164 4 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.50 • 12.8 155 • 231TP16(IS-OS)T/NT-5 036196 5 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.58 • 14.8 205 • 306TP16(IS-OS)T/NT-6 030165 6 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.63 • 16.1 240 • 356TP16(IS-OS)T/NT-7 036198 7 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.63 • 16.1 268 • 398TP16(IS-OS)T/NT-8 030166 8 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.69 • 17.4 300 • 446TP16(IS-OS)T/NT-9 036200 9 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.74 • 18.8 337 • 502TP16(IS-OS)T/NT-10 036201 10 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.81 • 20.4 373 • 555TP16(IS-OS)T/NT-11 036202 11 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.88 • 22.2 401 • 597TP16(IS-OS)T/NT-12 036203 12 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.88 • 22.2 466 • 693TP16(IS-OS)T/NT-13 036204 13 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.92 • 23.3 501 • 746TP16(IS-OS)T/NT-14 036205 14 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.92 • 23.3 530 • 788TP16(IS-OS)T/NT-15 030161 15 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.97 • 24.6 566 • 842TP16(IS-OS)T/NT-16 036207 16 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.97 • 24.6 594 • 884TP16(IS-OS)T/NT-17 036208 17 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.02 • 25.9 630 • 938TP16(IS-OS)T/NT-18 036209 18 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.02 • 25.9 659 • 981TP16(IS-OS)T/NT-19 036210 19 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.02 • 25.9 687 • 1023TP16(IS-OS)T/NT-20 030163 20 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.07 • 27.2 724 • 1077TP16(IS-OS)T/NT-21 036212 21 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.07 • 27.2 752 • 1119TP16(IS-OS)T/NT-22 036213 22 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.12 • 28.5 789 • 1174

indiv. & overall shielded twisted pair / aluminum or bronze armored16 AWG • 1.3 mm2 / 600V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TP16(IS)T/NT-1 030160* 1 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.34 • 8.7 67 • 100 108 • 161TP16(IS-OS)T/NT-2 030162* 2 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.48 • 12.2 84 • 125 143 • 213TP16(IS-OS)T/NT-3 036194* 3 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.51 • 13.0 151 • 225 215 • 320TP16(IS-OS)T/NT-4 030164* 4 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.55 • 14.0 185 • 275 253 • 376TP16(IS-OS)T/NT-5 036196* 5 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.63 • 16.0 239 • 356 318 • 473TP16(IS-OS)T/NT-6 030165* 6 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.68 • 17.3 277 • 412 362 • 539TP16(IS-OS)T/NT-7 036198* 7 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.68 • 17.3 305 • 454 390 • 580 TP16(IS-OS)T/NT-8 030166* 8 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.74 • 18.8 340 • 506 433 • 644TP16(IS-OS)T/NT-9 036200* 9 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.79 • 20.1 380 • 565 479 • 713TP16(IS-OS)T/NT-10 036201* 10 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.86 • 21.9 420 • 625 528 • 786TP16(IS-OS)T/NT-11 036202* 11 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.93 • 23.6 452 • 673 569 • 847TP16(IS-OS)T/NT-12 036203* 12 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.93 • 23.6 517 • 769 634 • 943TP16(IS-OS)T/NT-13 036204* 13 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.97 • 24.7 554 • 824 677 • 1007TP16(IS-OS)T/NT-14 036205* 14 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.97 • 24.7 583 • 868 706 • 1051TP16(IS-OS)T/NT-15 030161* 15 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.02 • 25.9 622 • 926 751 • 1117TP16(IS-OS)T/NT-16 036207* 16 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.02 • 25.9 650 • 967 779 • 1159TP16(IS-OS)T/NT-17 036208* 17 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.07 • 27.2 689 • 1025 824 • 1226TP16(IS-OS)T/NT-18 036209* 18 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.07 • 27.2 718 • 1068 853 • 1269TP16(IS-OS)T/NT-19 036210* 19 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.07 • 27.2 746 • 1110 881 • 1311TP16(IS-OS)T/NT-20 030163* 20 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.12 • 28.5 786 • 1170 928 • 1381TP16(IS-OS)T/NT-21 036212* 21 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.12 • 28.5 814 • 1211 956 • 1423TP16(IS-OS)T/NT-22 036213* 22 7/19.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.17 • 29.7 853 • 1269 1002 • 1491

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef TN-14Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

30

Page 38: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored & armored

18 AWG • 0.82 mm2 / 600V

APPLICATIONSBOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. TypeT/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTORS

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.Insulated conductors are rated VW1.

3. PAIR SHIELDAluminum / polyester tape with tinned copper drain wire to provide 100% coverageover the twisted pair, covered with a polyester tape.

4. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-510

DU

SA

_TN

11_0

905

CustRef TN-11

2

1

4

3

DrakaMarine Shipboard Cables

ISO9001QSC3497

DRAKA-USA

DR

AK

AM

OG

BO

STM

AR

INE

31

Page 39: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored & armored18 AWG • 0.82 mm2 / 600V

Insulation Jacket Cable Diameter Cable WeightTPC Part Number of Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km

TP18(IS)T/NT-1 029504 1 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.27 • 6.8 40 • 59TP18(IS-OS)T/NT-2 030171 2 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.39 • 10.0 74 • 111TP18(IS-OS)T/NT-3 029509 3 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.42 • 10.6 97 • 145TP18(IS-OS)T/NT-4 030173 4 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.46 • 11.6 122 • 181TP18(IS-OS)T/NT-5 029511 5 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.50 • 12.7 147 • 218TP18(IS-OS)T/NT-6 036176 6 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.57 • 14.6 189 • 282TP18(IS-OS)T/NT-7 029514 7 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.57 • 14.6 210 • 313TP18(IS-OS)T/NT-8 030174 8 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.62 • 15.7 237 • 352TP18(IS-OS)T/NT-9 036179 9 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.67 • 16.9 263 • 392TP18(IS-OS)T/NT-10 029503 10 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.72 • 18.4 291 • 433TP18(IS-OS)T/NT-11 036180 11 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.75 • 19.0 312 • 465TP18(IS-OS)T/NT-12 030170 12 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.75 • 19.0 336 • 500TP18(IS-OS)T/NT-13 036182 13 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.79 • 20.0 361 • 538TP18(IS-OS)T/NT-14 036183 14 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.79 • 20.0 383 • 570TP18(IS-OS)T/NT-15 036184 15 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.87 • 22.1 442 • 659TP18(IS-OS)T/NT-16 036185 16 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.87 • 22.1 464 • 690TP18(IS-OS)T/NT-17 036186 17 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.92 • 23.3 492 • 732TP18(IS-OS)T/NT-18 036187 18 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.92 • 23.3 513 • 763TP18(IS-OS)T/NT-19 036188 19 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.92 • 23.3 534 • 795TP18(IS-OS)T/NT-20 029507 20 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.96 • 24.5 562 • 837TP18(IS-OS)T/NT-21 036190 21 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.96 • 24.5 584 • 868TP18(IS-OS)T/NT-22 036191 22 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.01 • 25.7 613 • 912

indiv. & overall shielded twisted pair / aluminum or bronze armored18 AWG • 0.82 mm2 / 600V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TP18(IS)T/NT-1 029504* 1 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.32 • 8.2 57 • 85 95 • 141TP18(IS-OS)T/NT-2 030171* 2 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.44 • 11.2 97 • 144 152 • 226TP18(IS-OS)T/NT-3 029509* 3 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.47 • 12.0 122 • 182 180 • 268TP18(IS-OS)T/NT-4 030173* 4 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.40 • 10.2 149 • 222 213 • 317TP18(IS-OS)T/NT-5 029511* 5 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.55 • 14.0 177 • 263 245 • 365TP18(IS-OS)T/NT-6 036176* 6 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.62 • 15.8 223 • 332 300 • 446TP18(IS-OS)T/NT-7 029514* 7 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.62 • 15.8 244 • 363 321 • 478TP18(IS-OS)T/NT-8 030174* 8 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.67 • 17.0 273 • 406 257 • 382TP18(IS-OS)T/NT-9 036179* 9 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.72 • 18.3 302 • 449 393 • 585TP18(IS-OS)T/NT-10 029503* 10 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.77 • 19.6 333 • 496 430 • 640TP18(IS-OS)T/NT-11 036180* 11 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.80 • 20.3 356 • 530 456 • 679TP18(IS-OS)T/NT-12 030170* 12 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.80 • 20.3 380 • 565 480 • 714TP18(IS-OS)T/NT-13 036182* 13 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.84 • 21.4 407 • 606 513 • 763TP18(IS-OS)T/NT-14 036183* 14 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.84 • 21.4 429 • 638 535 • 796TP18(IS-OS)T/NT-15 036184* 15 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.92 • 23.4 492 • 732 608 • 905TP18(IS-OS)T/NT-16 036185* 16 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.92 • 23.4 514 • 765 630 • 937TP18(IS-OS)T/NT-17 036186* 17 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.97 • 24.7 545 • 811 668 • 994TP18(IS-OS)T/NT-18 036187* 18 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.97 • 24.7 566 • 842 689 • 1025TP18(IS-OS)T/NT-19 036188* 19 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.97 • 24.7 587 • 873 710 • 1056TP18(IS-OS)T/NT-20 029507* 20 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.01 • 25.7 617 • 918 745 • 1109TP18(IS-OS)T/NT-21 036190* 21 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.01 • 25.7 639 • 951 767 • 1141TP18(IS-OS)T/NT-22 036191* 22 7/15.2 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 1.06 • 26.9 671 • 998 806 • 1199

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef TN-12Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

32

Page 40: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored & armored

20 AWG • 0.52 mm2 / 300V

APPLICATIONSBOSTMARINE Type T/N 300 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 300 volts. TypeT/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTORS

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.Insulated conductors are rated VW1.

3. PAIR SHIELDAluminum / polyester tape with tinned copper drain wire to provide 100% coverageover the twisted pair, covered with a polyester tape.

4. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-510

DU

SA

_TN

09_1

005

CustRef TN-09

2

1

4

3

DrakaMarine Shipboard Cables

ISO9001QSC3497

DRAKA-USA

DR

AK

AM

OG

BO

STM

AR

INE

33

Page 41: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE T/N SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored20 AWG • 0.52 mm2 / 300V

Insulation Jacket Cable Diameter Cable WeightTPC Part Number of Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km

TP20(IS)T/NT-1 030190 1 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.25 • 6.3 33 • 49TP20(IS-OS)T/NT-2 030193 2 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.36 • 9.1 61 • 91TP20(IS-OS)T/NT-3 030194 3 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.38 • 9.7 80 • 119TP20(IS-OS)T/NT-4 030195 4 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.41 • 10.5 99 • 147TP20(IS-OS)T/NT-5 036154 5 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.45 • 11.5 118 • 175TP20(IS-OS)T/NT-6 036155 6 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.49 • 12.5 137 • 204TP20(IS-OS)T/NT-7 036156 7 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.49 • 12.5 153 • 228TP20(IS-OS)T/NT-8 036157 8 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.56 • 14.3 186 • 277TP20(IS-OS)T/NT-9 036158 9 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.61 • 15.4 211 • 314TP20(IS-OS)T/NT-10 029501 10 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.66 • 16.7 229 • 341TP20(IS-OS)T/NT-11 036159 11 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.68 • 17.2 245 • 365TP20(IS-OS)T/NT-12 030191 12 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.68 • 17.2 267 • 397TP20(IS-OS)T/NT-13 036161 13 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.71 • 18.1 287 • 427TP20(IS-OS)T/NT-14 036162 14 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.71 • 18.1 303 • 450TP20(IS-OS)T/NT-15 036163 15 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.75 • 19.1 323 • 481TP20(IS-OS)T/NT-16 036164 16 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.75 • 19.1 339 • 504TP20(IS-OS)T/NT-17 036165 17 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.79 • 20.2 360 • 535TP20(IS-OS)T/NT-18 036166 18 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.79 • 20.2 375 • 559TP20(IS-OS)T/NT-19 036167 19 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.79 • 20.2 391 • 582TP20(IS-OS)T/NT-20 036168 20 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.88 • 22.2 447 • 665TP20(IS-OS)T/NT-21 036169 21 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.88 • 22.2 463 • 689TP20(IS-OS)T/NT-22 036170 22 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.92 • 23.3 485 • 722

indiv. & overall shielded twisted pair / aluminum or bronze armored20 AWG • 0.52 mm2 / 300V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TP20(IS)T/NT-1 030190* 1 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.30 • 7.6 49 • 73 86 • 128TP20(IS-OS)T/NT-2 030193* 2 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.41 • 10.4 83 • 135 135 • 201TP20(IS-OS)T/NT-3 030194* 3 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.43 • 10.9 103 • 153 158 • 235TP20(IS-OS)T/NT-4 030195* 4 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.46 • 11.7 124 • 185 182 • 271TP20(IS-OS)T/NT-5 036154* 5 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.50 • 12.7 145 • 216 209 • 311TP20(IS-OS)T/NT-6 036155* 6 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.54 • 13.7 167 • 248 236 • 351TP20(IS-OS)T/NT-7 036156* 7 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.045 • 1.14 0.54 • 13.7 183 • 272 252 • 375TP20(IS-OS)T/NT-8 036157* 8 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.61 • 15.5 220 • 327 298 • 443TP20(IS-OS)T/NT-9 036158* 9 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.66 • 15.4 248 • 369 332 • 494TP20(IS-OS)T/NT-10 029501* 10 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.71 • 18.0 269 • 400 360 • 536TP20(IS-OS)T/NT-11 036159* 11 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.73 • 18.5 286 • 426 380 • 565TP20(IS-OS)T/NT-12 030191* 12 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.73 • 18.5 308 • 458 402 • 598TP20(IS-OS)T/NT-13 036161* 13 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.76 • 19.3 329 • 490 427 • 635TP20(IS-OS)T/NT-14 036162* 14 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.76 • 19.3 345 • 513 443 • 695TP20(IS-OS)T/NT-15 036163* 15 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.80 • 20.3 368 • 548 471 • 701TP20(IS-OS)T/NT-16 036164* 16 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.80 • 20.3 384 • 571 487 • 725TP20(IS-OS)T/NT-17 036165* 17 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.84 • 21.3 407 • 606 515 • 766TP20(IS-OS)T/NT-18 036166* 18 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.84 • 21.3 422 • 628 530 • 789TP20(IS-OS)T/NT-19 036167* 19 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.060 • 1.52 0.84 • 21.3 438 • 652 546 • 812TP20(IS-OS)T/NT-20 036168* 20 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.93 • 23.6 499 • 743 620 • 923TP20(IS-OS)T/NT-21 036169* 21 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.93 • 22.2 515 • 766 636 • 946TP20(IS-OS)T/NT-22 036170* 22 7/12.1 0.015 / 0.004 • 0.38 / 0.10 0.080 • 2.03 0.97 • 23.3 539 • 802 665 • 990

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 036150B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef TN-10Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

34

Page 42: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X CONTROL CABLEmulti-conductor / unarmored & armored

18, 16 and 14 AWG / 600V

APPLICATIONSBOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600volts. Type X cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTOR

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are ratedVW1. Thickness as shown in tables on the reverse.

3. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kV.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-501

DU

SA

_X07

_100

5

CustRef X-07

2

1

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

35

Page 43: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X CONTROL CABLEmulti-conductor / unarmored & armored18, 16 and 14 AWG / 600V

18 AWG • 1.0 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* Conductors Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

C18XT-2 036570 2 7/15.2 0.030 • 0.76 0.045 • 1.14 0.32 • 8.0 47 • 70 0.375 • 9.5 67 • 100 113 • 168C18XT-3 036571 3 7/15.2 0.030 • 0.76 0.045 • 1.14 0.33 • 8.4 56 • 83 0.385 • 9.8 77 • 115 124 • 185C18XT-4 036572 4 7/15.2 0.030 • 0.76 0.045 • 1.14 0.36 • 9.1 68 • 101 0.415 • 10.5 90 • 134 142 • 211C18XT-7 036573 7 7/15.2 0.030 • 0.76 0.045 • 1.14 0.42 • 10.8 99 • 147 0.475 • 12.1 125 • 186 184 • 274C18XT-10 036574 10 7/15.2 0.030 • 0.76 0.060 • 1.52 0.56 • 14.4 153 • 228 0.615 • 15.6 187 • 278 265 • 394C18XT-14 036575 14 7/15.2 0.030 • 0.76 0.060 • 1.52 0.61 • 15.5 195 • 290 0.665 • 16.9 232 • 345 316 • 470C18XT-19 036576 19 7/15.2 0.030 • 0.76 0.060 • 1.52 0.67 • 17.0 250 • 372 0.725 • 18.4 290 • 432 383 • 570C18XT-24 036577 24 7/15.2 0.030 • 0.76 0.060 • 1.52 0.78 • 19.8 308 • 458 0.835 • 21.2 354 • 527 462 • 687C18XT-30 036578 30 7/15.2 0.030 • 0.76 0.080 • 2.03 0.88 • 22.4 370 • 551 0.915 • 23.2 422 • 628 543 • 808C18XT-37 036579 37 7/15.2 0.030 • 0.76 0.080 • 2.03 0.93 • 23.6 480 • 714 0.985 • 25.0 535 • 796 662 • 985C18XT-44 036580 44 7/15.2 0.030 • 0.76 0.080 • 2.03 1.03 • 26.2 547 • 814 1.085 • 27.6 608 • 905 748 • 1113C18XT-61 036581 61 7/15.2 0.030 • 0.76 0.080 • 2.03 1.10 • 27.9 696 • 1036 1.155 • 29.3 761 • 1132 910 • 1354

16 AWG • 1.3 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* Conductors Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

C16XT-2 036582 2 7/19.2 0.030 • 0.76 0.045 • 1.14 0.34 • 8.6 57 • 85 0.395 • 10.0 78 • 116 127 • 189C16XT-3 036583 3 7/19.2 0.030 • 0.76 0.045 • 1.14 0.36 • 9.1 71 • 106 0.415 • 10.5 93 • 138 145 • 216C16XT-4 036584 4 7/19.2 0.030 • 0.76 0.045 • 1.14 0.39 • 9.9 87 • 129 0.445 • 11.3 111 • 165 167 • 248C16XT-7 036585 7 7/19.2 0.030 • 0.76 0.045 • 1.14 0.46 • 11.7 129 • 192 0.515 • 13.1 157 • 234 222 • 330C16XT-10 036053 10 7/19.2 0.030 • 0.76 0.060 • 1.52 0.61 • 15.6 197 • 293 0.665 • 16.9 234 • 348 318 • 473C16XT-14 036586 14 7/19.2 0.030 • 0.76 0.060 • 1.52 0.67 • 16.9 255 • 379 0.725 • 18.4 295 • 439 388 • 577C16XT-19 036587 19 7/19.2 0.030 • 0.76 0.060 • 1.52 0.73 • 18.7 328 • 488 0.785 • 19.9 372 • 553 472 • 702C16XT-24 036588 24 7/19.2 0.030 • 0.76 0.080 • 2.03 0.90 • 22.9 444 • 661 0.955 • 24.3 497 • 740 620 • 923C16XT-30 036589 30 7/19.2 0.030 • 0.76 0.080 • 2.03 0.95 • 24.1 529 • 787 1.005 • 25.5 585 • 870 715 • 1064C16XT-37 036590 37 7/19.2 0.030 • 0.76 0.080 • 2.03 1.02 • 25.9 631 • 939 1.075 • 27.3 691 • 1028 830 • 1235C16XT-44 036591 44 7/19.2 0.030 • 0.76 0.080 • 2.03 1.16 • 29.3 748 • 1113 1.215 • 30.9 816 • 1214 974 • 1449C16XT-61 036592 61 7/19.2 0.030 • 0.76 0.080 • 2.03 1.27 • 32.4 980 • 1458 1.325 • 33.7 1054 • 1568 1227 • 1825

14 AWG • 2.1 mm2

Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable WeightCable Type Number* Conductors Type in • mm in • mm in • mm Lbs/mft • Kg/km in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

C14XT-2 036593 2 7/24.2 0.030 • 0.76 0.045 • 1.14 0.37 • 9.4 72 • 107 0.425 • 10.8 95 • 141 148 • 220C14XT-3 036594 3 7/24.2 0.030 • 0.76 0.045 • 1.14 0.39 • 9.9 92 • 137 0.445 • 11.3 116 • 173 172 • 256C14XT-4 036595 4 7/24.2 0.030 • 0.76 0.045 • 1.14 0.42 • 10.8 114 • 170 0.475 • 12.1 140 • 208 199 • 296C14XT-7 036057 7 7/24.2 0.030 • 0.76 0.045 • 1.14 0.51 • 12.8 173 • 257 0.565 • 14.4 204 • 306 275 • 409C14XT-10 036596 10 7/24.2 0.030 • 0.76 0.060 • 1.52 0.68 • 17.1 261 • 388 0.735 • 18.7 302 • 449 396 • 589C14XT-14 036058 14 7/24.2 0.030 • 0.76 0.060 • 1.52 0.73 • 18.5 342 • 509 0.785 • 19.9 386 • 574 486 • 723C14XT-19 036597 19 7/24.2 0.030 • 0.76 0.060 • 1.52 0.81 • 20.6 444 • 661 0.865 • 22.0 492 • 732 603 • 897C14XT-24 036059 24 7/24.2 0.030 • 0.76 0.080 • 2.03 0.99 • 25.1 593 • 882 1.045 • 26.5 651 • 969 786 • 1170C14XT-30 036598 30 7/24.2 0.030 • 0.76 0.080 • 2.03 1.05 • 26.7 714 • 1063 1.105 • 28.1 776 • 1155 919 • 1367C14XT-37 036599 37 7/24.2 0.030 • 0.76 0.080 • 2.03 1.13 • 28.7 856 • 1274 1.185 • 30.1 922 • 1372 1076 • 1601C14XT-44 036600 44 7/24.2 0.030 • 0.76 0.080 • 2.03 1.27 • 32.3 1010 • 1503 1.325 • 33.7 1084 • 1613 1257 • 1870C14XT-61 036601 61 7/24.2 0.030 • 0.76 0.080 • 2.03 1.40 • 35.4 1350 • 2009 1.455 • 37.0 1432 • 2131 1621 • 2412

*NOTE: For aluminum armored versions, add an A (ex. 036570A). For bronze armored versions, add a B (ex. 036570B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef X-08Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

36

Page 44: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X POWER CABLEfour conductor / unarmored & armored

14 AWG to 500 MCM / 600V

APPLICATIONSBOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600volts. Type X cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTOR

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are ratedVW1. Thickness as shown in tables on the reverse.

3. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kV.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-501

DU

SA

_X05

_100

5

CustRef X-05

2

1

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

37

Page 45: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X POWER CABLEfour conductor / unarmored14 AWG to 500 MCM / 600V

Insulation Jacket Cable Diameter Cable WeightTPC Part Conductor Size Stranding Thickness Thickness (nominal) (approximate)Cable Type Number AWG/MCM • mm2 Type in • mm in • mm in • mm Lbs/mft • Kg/km

FXT-4 036563 14 • 2.1 7/24.2 0.030 • 0.76 0.045 • 1.14 0.440 • 11.2 120 • 179FXT-6 036564 12 • 3.3 7/30.5 0.030 • 0.76 0.045 • 1.14 0.485 • 12.3 164 • 244FXT-10 036052 10 • 5.3 7/38.5 0.030 • 0.76 0.060 • 1.52 0.575 • 14.6 241 • 359FXT-16 036565 8 • 8.4 7/48.6 0.045 • 1.14 0.060 • 1.52 0.730 • 18.5 382 • 568FXT-26 036566 6 • 13.3 7/61.2 0.045 • 1.14 0.060 • 1.52 0.830 • 21.1 542 • 806FXT-41 036015 4 • 21.1 7/77.2 0.045 • 1.14 0.080 • 2.03 0.990 • 25.1 824 • 1226FXT-66 036011 2 • 33.6 7/97.4 0.045 • 1.14 0.080 • 2.03 1.140 • 29.0 1205 • 1793FXT-83 030143 1 • 42.4 19/66.4 0.055 • 1.40 0.080 • 2.03 1.290 • 32.8 1500 • 2232FXT-106 030144 1/0 • 53.5 19/74.5 0.055 • 1.40 0.080 • 2.03 1.390 • 35.3 1782 • 2652FXT-133 030145 2/0 • 67.4 19/83.7 0.055 • 1.40 0.080 • 2.03 1.500 • 38.1 2220 • 3303FXT-168 030146 3/0 • 85.0 19/94.0 0.055 • 1.40 0.080 • 2.03 1.625 • 41.3 2706 • 4027FXT-212 030147 4/0 • 107.2 19/105.5 0.055 • 1.40 0.110 • 2.79 1.830 • 46.5 3444 • 5125FXT-250 030183 250 • 127.0 37/82.2 0.065 • 1.65 0.110 • 2.79 2.000 • 50.8 4002 • 5955FXT-300 036568 300 • 152.0 37/90.0 0.065 • 1.65 0.110 • 2.79 2.130 • 54.1 4680 • 6964FXT-350 030389 350 • 177.0 37/97.3 0.065 • 1.65 0.110 • 2.79 2.260 • 57.4 5464 • 8130FXT-400 036569 400 • 203.0 37/104.0 0.065 • 1.65 0.110 • 2.79 2.370 • 60.2 6140 • 9136FXT-500 030647 500 • 253.0 37/116.2 0.065 • 1.65 0.110 • 2.79 2.580 • 65.5 7560 • 11250

four conductor / aluminum or bronze armored14 AWG to 500 MCM / 600V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Conductor Size Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* AWG/MCM • mm2 Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

FXT-4 036563* 14 • 2.1 7/24.2 0.030 • 0.76 0.045 • 1.14 0.495 • 12.6 147 • 219 209 • 311FXT-6 036564* 12 • 3.3 7/30.5 0.030 • 0.76 0.045 • 1.14 0.540 • 13.7 193 • 287 262 • 390FXT-10 036052* 10 • 5.3 7/38.5 0.030 • 0.76 0.060 • 1.52 0.630 • 16.0 276 • 411 356 • 530FXT-16 036565* 8 • 8.4 7/48.6 0.045 • 1.14 0.060 • 1.52 0.785 • 19.9 426 • 634 526 • 783FXT-26 036566* 6 • 13.3 7/61.2 0.045 • 1.14 0.060 • 1.52 0.885 • 22.5 591 • 879 705 • 1049FXT-41 036015* 4 • 21.1 7/77.2 0.045 • 1.14 0.080 • 2.03 1.045 • 26.5 882 • 1312 1017 • 1513FXT-66 036011* 2 • 33.6 7/97.4 0.045 • 1.14 0.080 • 2.03 1.195 • 30.4 1272 • 1893 1427 • 2123FXT-83 030143* 1 • 42.4 19/66.4 0.055 • 1.40 0.080 • 2.03 1.345 • 34.2 1576 • 2345 1750 • 2604FXT-106 030144* 1/0 • 53.5 19/74.5 0.055 • 1.40 0.080 • 2.03 1.445 • 36.7 1863 • 2772 2051 • 3052FXT-133 030145* 2/0 • 67.4 19/83.7 0.055 • 1.40 0.080 • 2.03 1.555 • 39.5 2308 • 3434 2510 • 3735FXT-168 030146* 3/0 • 85.0 19/94.0 0.055 • 1.40 0.080 • 2.03 1.680 • 42.7 2801 • 4168 3020 • 4494FXT-212 030147* 4/0 • 107.2 19/105.5 0.055 • 1.40 0.110 • 2.79 1.885 • 47.9 3551 • 5284 3797 • 5650FXT-250 030183* 250 • 127.0 37/82.2 0.065 • 1.65 0.110 • 2.79 2.055 • 52.2 4118 • 6128 4387 • 6528FXT-300 036568* 300 • 152.0 37/90.0 0.065 • 1.65 0.110 • 2.79 2.185 • 55.5 4804 • 7148 5090 • 7574FXT-350 030389* 350 • 177.0 37/97.3 0.065 • 1.65 0.110 • 2.79 2.315 • 58.8 5595 • 8325 5899 • 8778FXT-400 036569* 400 • 203.0 37/104.0 0.065 • 1.65 0.110 • 2.79 2.425 • 61.6 6278 • 9342 6595 • 9813FXT-500 030647* 500 • 253.0 37/116.2 0.065 • 1.65 0.110 • 2.79 2.635 • 66.9 7710 • 11472 8055 • 11986

*NOTE: For aluminum armored versions, add an A (ex. 036563A). For bronze armored versions, add a B (ex. 030103B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef X-06Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 1281-209-3857 fax • www.drakausa.com

38

Page 46: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X POWER CABLEthree conductor / unarmored & armored

14 AWG to 1000 MCM / 600V

APPLICATIONSBOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600volts. Type X cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTOR

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are ratedVW1. Thickness as shown in tables on the reverse.

3. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kV.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-501

DU

SA

_X03

_100

5

CustRef X-03

2

1

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

39

Page 47: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X POWER CABLEthree conductor / unarmored14 AWG to 1000 MCM / 600V

Insulation Jacket Cable Diameter Cable WeightTPC Part Conductor Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Size Type in • mm in • mm in • mm Lbs/mft • Kg/km

TXT-4 030125 14 • 2.1 7/24.2 0.030 • 0.76 0.045 • 1.14 0.400 • 10.2 90 • 134TXT-6 030113 12 • 3.3 7/30.5 0.030 • 0.76 0.045 • 1.14 0.440 • 11.2 120 • 179TXT-10 036010 10 • 5.3 7/38.5 0.030 • 0.76 0.045 • 1.14 0.500 • 12.7 170 • 253TXT-16 036009 8 • 8.4 7/48.6 0.045 • 1.14 0.060 • 1.52 0.670 • 17.1 280 • 417TXT-26 036055 6 • 13.3 7/61.2 0.045 • 1.14 0.060 • 1.52 0.750 • 19.1 395 • 588TXT-41 036008 4 • 21.1 7/77.2 0.045 • 1.14 0.080 • 2.03 0.900 • 23.0 570 • 848TXT-66 036007 2 • 33.6 7/97.4 0.045 • 1.14 0.080 • 2.03 1.030 • 26.2 875 • 1302TXT-83 030126 1 • 42.4 19/66.4 0.055 • 1.40 0.080 • 2.03 1.160 • 29.5 1090 • 1622TXT-106 030127 1/0 • 53.5 19/74.5 0.055 • 1.40 0.080 • 2.03 1.255 • 31.9 1320 • 1964TXT-133 030140 2/0 • 67.4 19/83.7 0.055 • 1.40 0.080 • 2.03 1.355 • 34.4 1615 • 2403TXT-168 030141 3/0 • 85.0 19/94.0 0.055 • 1.40 0.080 • 2.03 1.470 • 37.3 1980 • 2947TXT-212 030142 4/0 • 107.2 19/105.5 0.055 • 1.40 0.080 • 2.03 1.595 • 40.5 2435 • 3624TXT-250 030158 250 • 127.0 37/82.2 0.065 • 1.65 0.110 • 2.79 1.810 • 46.0 2965 • 4412TXT-300 036559 300 • 152.0 37/90.0 0.065 • 1.65 0.110 • 2.79 1.930 • 49.0 3485 • 5186TXT-350 030124 350 • 177.0 37/97.3 0.065 • 1.65 0.110 • 2.79 2.040 • 51.8 4005 • 5960TXT-400 030200 400 • 203.0 37/104.0 0.065 • 1.65 0.110 • 2.79 2.140 • 54.4 4525 • 6734TXT-500 030647 500 • 253.0 37/116.2 0.065 • 1.65 0.110 • 2.79 2.330 • 59.2 5545 • 8252TXT-750 036561 750 • 380.0 61/110.9 0.080 • 2.03 0.140 • 3.56 2.865 • 72.8 8420 • 12530TXT-1000 036562 1000 • 507.0 61/128.0 0.080 • 2.03 0.140 • 3.56 3.200 • 81.3 11000 • 16370

three conductor / aluminum or bronze armored14 AWG to 1000 MCM / 600V

Insulationj Jacket Armored Aluminum arm. Bronze arm.TPC Part Conductor Size Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* AWG/MCM • mm2 Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TXT-4 030125* 14 • 2.1 7/24.2 0.030 • 0.76 0.045 • 1.14 0.440 • 11.2 115 • 171 171 • 254TXT-6 030113* 12 • 3.3 7/30.5 0.030 • 0.76 0.045 • 1.14 0.490 • 12.5 147 • 219 209 • 311TXT-10 036010* 10 • 5.3 7/38.5 0.030 • 0.76 0.045 • 1.14 0.550 • 14.0 200 • 298 270 • 402TXT-16 036009* 8 • 8.4 7/48.6 0.045 • 1.14 0.060 • 1.52 0.720 • 18.3 320 • 476 413 • 615 TXT-26 036055* 6 • 13.3 7/61.2 0.045 • 1.14 0.060 • 1.52 0.880 • 22.4 440 • 655 543 • 808TXT-41 036008* 4 • 21.1 7/77.2 0.045 • 1.14 0.080 • 2.03 0.950 • 24.2 623 • 927 746 • 1110TXT-66 036007* 2 • 33.6 7/97.4 0.045 • 1.14 0.080 • 2.03 1.080 • 27.6 936 • 1393 1076 • 1601TXT-83 030126* 1 • 42.4 19/66.4 0.055 • 1.40 0.080 • 2.03 1.210 • 30.8 1158 • 1732 1316 • 1958TXT-106 030127* 1/0 • 53.5 19/74.5 0.055 • 1.40 0.080 • 2.03 1.310 • 33.3 1394 • 2074 1564 • 2327TXT-133 030140* 2/0 • 67.4 19/83.7 0.055 • 1.40 0.080 • 2.03 1.410 • 35.8 1694 • 2521 1878 • 2794TXT-168 030141* 3/0 • 85.0 19/94.0 0.055 • 1.40 0.080 • 2.03 1.520 • 38.6 2066 • 3074 2265 • 3370TXT-212 030142* 4/0 • 107.2 19/105.5 0.055 • 1.40 0.080 • 2.03 1.650 • 41.9 2528 • 3762 2743 • 4082TXT-250 030158* 250 • 127.0 37/82.2 0.065 • 1.65 0.110 • 2.79 1.860 • 47.3 3070 • 4568 3314 • 4931TXT-300 036559* 300 • 152.0 37/90.0 0.065 • 1.65 0.110 • 2.79 1.980 • 50.3 3597 • 5352 3857 • 5739TXT-350 030124* 350 • 177.0 37/97.3 0.065 • 1.65 0.110 • 2.79 2.090 • 53.1 4124 • 6137 4398 • 6544TXT-400 030200* 400 • 203.0 37/104.0 0.065 • 1.65 0.110 • 2.79 2.190 • 55.7 4649 • 6918 4937 • 7346TXT-500 030647* 500 • 253.0 37/116.2 0.065 • 1.65 0.110 • 2.79 2.380 • 60.5 5680 • 8452 5993 • 8918TXT-750 036561* 750 • 380.0 61/110.9 0.080 • 2.03 0.140 • 3.56 2.920 • 74.2 8586 • 12776 8969 • 13346TXT-1000 036562* 1000 • 507.0 61/128.0 0.080 • 2.03 0.140 • 3.56 3.250 • 82.6 11185 • 16643 11613 • 17280

*NOTE: For aluminum armored versions, add an A (ex. 036012A). For bronze armored versions, add a B (ex. 030103B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef X-04Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 1281-209-3857 fax • www.drakausa.com

40

Page 48: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X POWER CABLEtwo conductor / unarmored & armored

14 AWG to 1000 MCM / 600V

APPLICATIONSBOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600volts. Type X cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTOR

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are ratedVW1. Thickness as shown in tables on the reverse.

3. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kV.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-501

DU

SA

_X01

_100

5

CustRef X-01

2

1

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

41

Page 49: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X POWER CABLEtwo conductor / unarmored14 AWG to 1000 MCM / 600V

Insulation Jacket Cable Diameter Cable WeightTPC Part Conductor Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Size Type in • mm in • mm in • mm Lbs/mft • Kg/km

DXT-4 036012 14 • 2.1 7/24.2 0.030 • 0.76 0.045 • 1.14 0.380 • 9.7 81 • 121DXT-6 036013 12 • 3.3 7/30.5 0.030 • 0.76 0.045 • 1.14 0.420 • 10.7 98 • 146DXT-10 036050 10 • 5.3 7/38.5 0.030 • 0.76 0.045 • 1.14 0.470 • 11.9 138 • 205DXT-16 036051 8 • 8.4 7/48.6 0.045 • 1.14 0.060 • 1.52 0.630 • 16.0 234 • 348DXT-26 036542 6 • 13.3 7/61.2 0.045 • 1.14 0.060 • 1.52 0.705 • 17.9 280 • 417DXT-41 036543 4 • 21.1 7/77.2 0.045 • 1.14 0.060 • 1.52 0.810 • 20.6 448 • 667DXT-66 036544 2 • 33.6 7/97.4 0.045 • 1.14 0.080 • 2.03 0.970 • 24.6 682 • 1015DXT-83 036545 1 • 42.4 19/66.4 0.055 • 1.40 0.080 • 2.03 1.090 • 27.7 835 • 1242DXT-106 036546 1/0 • 53.5 19/74.5 0.055 • 1.40 0.080 • 2.03 1.180 • 30.0 915 • 1362DXT-133 036547 2/0 • 67.4 19/83.7 0.055 • 1.40 0.080 • 2.03 1.270 • 32.3 1222 • 1818DXT-168 036548 3/0 • 85.0 19/94.0 0.055 • 1.40 0.080 • 2.03 1.380 • 35.1 1491 • 2219DXT-212 036549 4/0 • 107.2 19/105.5 0.055 • 1.40 0.080 • 2.03 1.490 • 37.8 1805 • 2686DXT-250 036550 250 • 127.0 37/82.2 0.065 • 1.65 0.080 • 2.03 1.630 • 41.4 1945 • 2894DXT-300 036551 300 • 152.0 37/90.0 0.065 • 1.65 0.110 • 2.79 1.810 • 46.0 2385 • 3549DXT-350 036552 350 • 177.0 37/97.3 0.065 • 1.65 0.110 • 2.79 1.910 • 48.5 2735 • 4070DXT-400 036553 400 • 203.0 37/104.0 0.065 • 1.65 0.110 • 2.79 2.005 • 50.9 3080 • 4584DXT-500 036554 500 • 253.0 37/116.2 0.065 • 1.65 0.110 • 2.79 2.180 • 55.4 3755 • 5588DXT-600 036555 600 • 304.0 61/99.2 0.080 • 2.03 0.110 • 2.79 2.405 • 61.1 4530 • 6741DXT-750 036556 750 • 380.0 61/110.9 0.080 • 2.03 0.110 • 2.79 2.620 • 66.5 5550 • 8259DXT-1000 036557 1000 • 507.0 61/128.0 0.080 • 2.03 0.140 • 3.56 2.995 • 76.1 7390 • 10997

two conductor / aluminum or bronze armored14 AWG to 1000 MCM / 600V

Insulationj Jacket Armored Aluminum arm. Bronze arm.TPC Part Conductor Size Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* AWG/MCM • mm2 Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

DXT-4 036012* 14 • 2.1 7/24.2 0.030 • 0.76 0.045 • 1.14 0.435 • 11.0 104 • 155 159 • 237DXT-6 036013* 12 • 3.3 7/30.5 0.030 • 0.76 0.045 • 1.14 0.475 • 12.1 124 • 185 183 • 272 DXT-10 036050* 10 • 5.3 7/38.5 0.030 • 0.76 0.045 • 1.14 0.525 • 13.3 167 • 248 233 • 347DXT-16 036051* 8 • 8.4 7/48.6 0.045 • 1.14 0.060 • 1.52 0.685 • 17.4 272 • 405 359 • 534 DXT-26 036542* 6 • 13.3 7/61.2 0.045 • 1.14 0.060 • 1.52 0.760 • 19.3 322 • 479 419 • 623DXT-41 036543* 4 • 21.1 7/77.2 0.045 • 1.14 0.060 • 1.52 0.865 • 22.0 496 • 738 607 • 903 DXT-66 036544* 2 • 33.6 7/97.4 0.045 • 1.14 0.080 • 2.03 1.025 • 26.0 739 • 1100 872 • 1298DXT-83 036545* 1 • 42.4 19/66.4 0.055 • 1.40 0.080 • 2.03 1.145 • 29.1 899 • 1338 1047 • 1558 DXT-106 036546* 1/0 • 53.5 19/74.5 0.055 • 1.40 0.080 • 2.03 1.235 • 31.4 984 • 1464 1145 • 1704DXT-133 036547* 2/0 • 67.4 19/83.7 0.055 • 1.40 0.080 • 2.03 1.325 • 33.7 1296 • 1928 1469 • 2632DXT-168 036548* 3/0 • 85.0 19/94.0 0.055 • 1.40 0.080 • 2.03 1.435 • 36.4 1572 • 2339 1758 • 2616DXT-212 036549* 4/0 • 107.2 19/105.5 0.055 • 1.40 0.080 • 2.03 1.545 • 39.2 1892 • 2815 2093 • 3114DXT-250 036550* 250 • 127.0 37/82.2 0.065 • 1.65 0.080 • 2.03 1.685 • 42.3 2040 • 3036 2260 • 3363DXT-300 036551* 300 • 152.0 37/90.0 0.065 • 1.65 0.110 • 2.79 1.865 • 47.4 2490 • 3705 2734 • 4068DXT-350 036552* 350 • 177.0 37/97.3 0.065 • 1.65 0.110 • 2.79 1.965 • 49.9 2846 • 4235 3103 • 4617 DXT-400 036553* 400 • 203.0 37/104.0 0.065 • 1.65 0.110 • 2.79 2.060 • 52.3 3197 • 4757 3466 • 5157DXT-500 036554* 500 • 253.0 37/116.2 0.065 • 1.65 0.110 • 2.79 2.235 • 56.8 3882 • 5776 4174 • 6211DXT-600 036555* 600 • 304.0 61/99.2 0.080 • 2.03 0.110 • 2.79 2.460 • 62.5 4670 • 6949 4991 • 7427DXT-750 036556* 750 • 380.0 61/110.9 0.080 • 2.03 0.110 • 2.79 2.675 • 67.9 5702 • 8485 6053 • 9007 DXT-1000 036557* 1000 • 507.0 61/128.0 0.080 • 2.03 0.140 • 3.56 3.055 • 77.6 7563 • 11254 7964 • 11850

*NOTE: For aluminum armored versions, add an A (ex. 036012A). For bronze armored versions, add a B (ex. 030103B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef X-02Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 1281-209-3857 fax • www.drakausa.com

42

Page 50: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored & armored

16 AWG • 1.31 mm2 / 600V

APPLICATIONSBOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600volts. Type X cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTORS

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are ratedVW1. Thickness as shown in tables on the reverse.

3. PAIR SHIELDAluminum / polyester tape with tinned copper drain wire to provide 100% coverageover the twisted pair, covered with a polyester tape.

4. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kV.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-511

DU

SA

_X13

_100

5

CustRef X-13

2

1

4

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

43

Page 51: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored 16 AWG • 1.31 mm2 / 600V

Insulation Jacket Cable Diameter Cable WeightTPC Part Number of Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km

TP16(IS)XT-1 036646 1 7/19.2 0.025 • 0.64 0.045 • 1.14 0.32 • 8.1 56 • 83TP16(IS-OS)XT-2 036647 2 7/19.2 0.025 • 0.64 0.045 • 1.14 0.50 • 12.7 104 • 155TP16(IS-OS)XT-3 036648 3 7/19.2 0.025 • 0.64 0.060 • 1.52 0.56 • 14.2 153 • 228TP16(IS-OS)XT-4 036649 4 7/19.2 0.025 • 0.64 0.060 • 1.52 0.61 • 15.5 190 • 283TP16(IS-OS)XT-5 036650 5 7/19.2 0.025 • 0.64 0.060 • 1.52 0.67 • 17.0 227 • 338TP16(IS-OS)XT-6 036651 6 7/19.2 0.025 • 0.64 0.060 • 1.52 0.73 • 18.5 265 • 394TP16(IS-OS)XT-7 036652 7 7/19.2 0.025 • 0.64 0.060 • 1.52 0.73 • 18.5 295 • 439TP16(IS-OS)XT-8 036653 8 7/19.2 0.025 • 0.64 0.060 • 1.52 0.79 • 20.1 332 • 494TP16(IS-OS)XT-9 036654 9 7/19.2 0.025 • 0.64 0.080 • 2.03 0.89 • 22.6 370 • 551TP16(IS-OS)XT-10 036655 10 7/19.2 0.025 • 0.64 0.080 • 2.03 0.97 • 24.6 449 • 668TP16(IS-OS)XT-11 036656 11 7/19.2 0.025 • 0.64 0.080 • 2.03 0.99 • 25.1 487 • 724TP16(IS-OS)XT-12 036657 12 7/19.2 0.025 • 0.64 0.080 • 2.03 0.99 • 25.1 516 • 768TP16(IS-OS)XT-13 036658 13 7/19.2 0.025 • 0.64 0.080 • 2.03 1.04 • 26.4 555 • 826TP16(IS-OS)XT-14 036659 14 7/19.2 0.025 • 0.64 0.080 • 2.03 1.04 • 26.4 585 • 870TP16(IS-OS)XT-15 036660 15 7/19.2 0.025 • 0.64 0.080 • 2.03 1.10 • 27.9 621 • 924TP16(IS-OS)XT-16 036661 16 7/19.2 0.025 • 0.64 0.080 • 2.03 1.10 • 27.9 654 • 974TP16(IS-OS)XT-17 036662 17 7/19.2 0.025 • 0.64 0.080 • 2.03 1.15 • 29.2 694 • 1033TP16(IS-OS)XT-18 036663 18 7/19.2 0.025 • 0.64 0.080 • 2.03 1.15 • 29.2 724 • 1078TP16(IS-OS)XT-19 036664 19 7/19.2 0.025 • 0.64 0.080 • 2.03 1.15 • 29.2 754 • 1122TP16(IS-OS)XT-20 036665 20 7/19.2 0.025 • 0.64 0.080 • 2.03 1.21 • 30.7 790 • 1176TP16(IS-OS)XT-21 036666 21 7/19.2 0.025 • 0.64 0.080 • 2.03 1.21 • 30.7 824 • 1226TP16(IS-OS)XT-22 036667 22 7/19.2 0.025 • 0.64 0.080 • 2.03 1.28 • 32.5 865 • 1287

indiv. & overall shielded twisted pair / aluminum or bronze armored16 AWG • 1.31 mm2 / 600V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TP16(IS)XT-1 036646* 1 7/19.2 0.025 • 0.64 0.045 • 1.14 0.375 • 9.5 76 • 113 122 • 182TP16(IS-OS)XT-2 036647* 2 7/19.2 0.025 • 0.64 0.045 • 1.14 0.555 • 14.1 134 • 199 204 • 304TP16(IS-OS)XT-3 036648* 3 7/19.2 0.025 • 0.64 0.060 • 1.52 0.615 • 15.6 187 • 278 265 • 394TP16(IS-OS)XT-4 036649* 4 7/19.2 0.025 • 0.64 0.060 • 1.52 0.665 • 16.9 227 • 338 311 • 463TP16(IS-OS)XT-5 036650* 5 7/19.2 0.025 • 0.64 0.060 • 1.52 0.725 • 18.4 267 • 397 360 • 534TP16(IS-OS)XT-6 036651* 6 7/19.2 0.025 • 0.64 0.060 • 1.52 0.785 • 19.9 309 • 460 409 • 609TP16(IS-OS)XT-7 036652* 7 7/19.2 0.025 • 0.64 0.060 • 1.52 0.785 • 19.9 368 • 548 439 • 653TP16(IS-OS)XT-8 036653* 8 7/19.2 0.025 • 0.64 0.060 • 1.52 0.845 • 21.4 379 • 564 487 • 725TP16(IS-OS)XT-9 036654* 9 7/19.2 0.025 • 0.64 0.080 • 2.03 0.945 • 24.0 423 • 629 544 • 809TP16(IS-OS)XT-10 036655* 10 7/19.2 0.025 • 0.64 0.080 • 2.03 1.025 • 26.0 506 • 753 639 • 951TP16(IS-OS)XT-11 036656* 11 7/19.2 0.025 • 0.64 0.080 • 2.03 1.045 • 26.5 545 • 811 680 • 1012TP16(IS-OS)XT-12 036657* 12 7/19.2 0.025 • 0.64 0.080 • 2.03 1.045 • 26.5 574 • 854 709 • 1055TP16(IS-OS)XT-13 036658* 13 7/19.2 0.025 • 0.64 0.080 • 2.03 1.095 • 27.8 616 • 917 758 • 1128TP16(IS-OS)XT-14 036659* 14 7/19.2 0.025 • 0.64 0.080 • 2.03 1.095 • 27.8 646 • 961 788 • 1173TP16(IS-OS)XT-15 036660* 15 7/19.2 0.025 • 0.64 0.080 • 2.03 1.155 • 29.3 686 • 1021 835 • 1242TP16(IS-OS)XT-16 036661* 16 7/19.2 0.025 • 0.64 0.080 • 2.03 1.155 • 29.3 719 • 1070 868 • 1292TP16(IS-OS)XT-17 036662* 17 7/19.2 0.025 • 0.64 0.080 • 2.03 1.205 • 24.2 762 • 1134 918 • 1366TP16(IS-OS)XT-18 036663* 18 7/19.2 0.025 • 0.64 0.080 • 2.03 1.205 • 24.2 792 • 1178 948 • 1411TP16(IS-OS)XT-19 036664* 19 7/19.2 0.025 • 0.64 0.080 • 2.03 1.205 • 24.2 822 • 1123 978 • 1455TP16(IS-OS)XT-20 036665* 20 7/19.2 0.025 • 0.64 0.080 • 2.03 1.265 • 32.1 861 • 1281 1025 • 1525TP16(IS-OS)XT-21 036666* 21 7/19.2 0.025 • 0.64 0.080 • 2.03 1.265 • 32.1 895 • 1332 1059 • 1576TP16(IS-OS)XT-22 036667* 22 7/19.2 0.025 • 0.64 0.080 • 2.03 1.335 • 33.9 940 • 1399 1113 • 1656

*NOTE: For aluminum armored versions, add an A (ex. 036646A). For bronze armored versions, add a B (ex. 036646B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef X-14Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

44

Page 52: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored & armored

18 AWG • 0.82 mm2 / 600V

APPLICATIONSBOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600volts. Type X cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTORS

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are ratedVW1. Thickness as shown in tables on the reverse.

3. PAIR SHIELDAluminum / polyester tape with tinned copper drain wire to provide 100% coverageover the twisted pair, covered with a polyester tape.

4. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kV.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-511

DU

SA

_X11

_100

5

CustRef X-11

2

1

4

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

45

Page 53: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored18 AWG • 0.82 mm2 / 600V

Insulation Jacket Cable Diameter Cable WeightTPC Part Number of Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km

TP18(IS)XT-1 036624 1 7/15.2 0.025 • 0.64 0.045 • 1.14 0.30 • 7.6 46 • 68TP18(IS-OS)XT-2 036625 2 7/15.2 0.025 • 0.64 0.045 • 1.14 0.45 • 11.4 85 • 126TP18(IS-OS)XT-3 036626 3 7/15.2 0.025 • 0.64 0.045 • 1.14 0.48 • 12.2 109 • 162TP18(IS-OS)XT-4 036627 4 7/15.2 0.025 • 0.64 0.060 • 1.52 0.59 • 15.0 153 • 228TP18(IS-OS)XT-5 036628 5 7/15.2 0.025 • 0.64 0.060 • 1.52 0.61 • 15.5 182 • 271TP18(IS-OS)XT-6 036629 6 7/15.2 0.025 • 0.64 0.060 • 1.52 0.66 • 16.8 211 • 314TP18(IS-OS)XT-7 036630 7 7/15.2 0.025 • 0.64 0.060 • 1.52 0.66 • 16.8 232 • 346TP18(IS-OS)XT-8 036631 8 7/15.2 0.025 • 0.64 0.060 • 1.52 0.72 • 18.3 262 • 390TP18(IS-OS)XT-9 036632 9 7/15.2 0.025 • 0.64 0.060 • 1.52 0.78 • 19.8 290 • 432TP18(IS-OS)XT-10 036633 10 7/15.2 0.025 • 0.64 0.080 • 2.03 0.89 • 22.6 359 • 534TP18(IS-OS)XT-11 036634 11 7/15.2 0.025 • 0.64 0.080 • 2.03 0.91 • 23.1 346 • 516TP18(IS-OS)XT-12 036635 12 7/15.2 0.025 • 0.64 0.080 • 2.03 0.91 • 23.1 368 • 548TP18(IS-OS)XT-13 036636 13 7/15.2 0.025 • 0.64 0.080 • 2.03 0.96 • 24.4 438 • 652TP18(IS-OS)XT-14 036637 14 7/15.2 0.025 • 0.64 0.080 • 2.03 0.96 • 24.4 459 • 684TP18(IS-OS)XT-15 036638 15 7/15.2 0.025 • 0.64 0.080 • 2.03 1.01 • 25.7 490 • 729TP18(IS-OS)XT-16 036639 16 7/15.2 0.025 • 0.64 0.080 • 2.03 1.01 • 25.7 512 • 762TP18(IS-OS)XT-17 036640 17 7/15.2 0.025 • 0.64 0.080 • 2.03 1.06 • 26.9 543 • 808TP18(IS-OS)XT-18 036641 18 7/15.2 0.025 • 0.64 0.080 • 2.03 1.06 • 26.9 565 • 840TP18(IS-OS)XT-19 036642 19 7/15.2 0.025 • 0.64 0.080 • 2.03 1.06 • 26.9 586 • 872TP18(IS-OS)XT-20 036643 20 7/15.2 0.025 • 0.64 0.080 • 2.03 1.11 • 28.2 619 • 921TP18(IS-OS)XT-21 036644 21 7/15.2 0.025 • 0.64 0.080 • 2.03 1.11 • 28.2 639 • 951TP18(IS-OS)XT-22 036645 22 7/15.2 0.025 • 0.64 0.080 • 2.03 1.16 • 29.5 671 • 998

indiv. & overall shielded twisted pair / aluminum & bronze armored18 AWG • 0.82 mm2 / 600V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TP18(IS)XT-1 036624* 1 7/15.2 0.025 • 0.64 0.045 • 1.14 0.355 • 9.0 65 • 97 108 • 161TP18(IS-OS)XT-2 036625* 2 7/15.2 0.025 • 0.64 0.045 • 1.14 0.505 • 12.8 112 • 167 176 • 262TP18(IS-OS)XT-3 036626* 3 7/15.2 0.025 • 0.64 0.045 • 1.14 0.535 • 13.6 138 • 205 206 • 307TP18(IS-OS)XT-4 036627* 4 7/15.2 0.025 • 0.64 0.060 • 1.52 0.645 • 16.4 188 • 280 271 • 403TP18(IS-OS)XT-5 036628* 5 7/15.2 0.025 • 0.64 0.060 • 1.52 0.665 • 16.9 219 • 326 303 • 451TP18(IS-OS)XT-6 036629* 6 7/15.2 0.025 • 0.64 0.060 • 1.52 0.715 • 18.2 251 • 373 342 • 509TP18(IS-OS)XT-7 036630* 7 7/15.2 0.025 • 0.64 0.060 • 1.52 0.715 • 18.2 272 • 405 363 • 540TP18(IS-OS)XT-8 036631* 8 7/15.2 0.025 • 0.64 0.060 • 1.52 0.775 • 19.7 305 • 454 404 • 601TP18(IS-OS)XT-9 036632* 9 7/15.2 0.025 • 0.64 0.060 • 1.52 0.835 • 21.2 336 • 500 444 • 661TP18(IS-OS)XT-10 036633* 10 7/15.2 0.025 • 0.64 0.080 • 2.03 0.925 • 23.5 364 • 542 478 • 711TP18(IS-OS)XT-11 036634* 11 7/15.2 0.025 • 0.64 0.080 • 2.03 0.965 • 24.5 393 • 585 512 • 762TP18(IS-OS)XT-12 036635* 12 7/15.2 0.025 • 0.64 0.080 • 2.03 0.965 • 24.5 422 • 628 546 • 812TP18(IS-OS)XT-13 036636* 13 7/15.2 0.025 • 0.64 0.080 • 2.03 1.015 • 25.8 495 • 737 626 • 931TP18(IS-OS)XT-14 036637* 14 7/15.2 0.025 • 0.64 0.080 • 2.03 1.015 • 25.8 516 • 768 647 • 963TP18(IS-OS)XT-15 036638* 15 7/15.2 0.025 • 0.64 0.080 • 2.03 1.065 • 27.1 550 • 818 687 • 1022TP18(IS-OS)XT-16 036639* 16 7/15.2 0.025 • 0.64 0.080 • 2.03 1.065 • 27.1 572 • 851 709 • 1055TP18(IS-OS)XT-17 036640* 17 7/15.2 0.025 • 0.64 0.080 • 2.03 1.115 • 28.3 605 • 900 750 • 1116TP18(IS-OS)XT-18 036641* 18 7/15.2 0.025 • 0.64 0.080 • 2.03 1.115 • 28.3 627 • 933 772 • 1149TP18(IS-OS)XT-19 036642* 19 7/15.2 0.025 • 0.64 0.080 • 2.03 1.115 • 28.3 648 • 964 793 • 1180TP18(IS-OS)XT-20 036643* 20 7/15.2 0.025 • 0.64 0.080 • 2.03 1.165 • 29.6 684 • 1018 835 • 1242TP18(IS-OS)XT-21 036644* 21 7/15.2 0.025 • 0.64 0.080 • 2.03 1.165 • 29.6 704 • 1048 855 • 1272TP18(IS-OS)XT-22 036645* 22 7/15.2 0.025 • 0.64 0.080 • 2.03 1.215 • 30.9 739 • 1100 897 • 1335

*NOTE: For aluminum armored versions, add an A (ex. 036624A). For bronze armored versions, add a B (ex. 036624B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef X-12Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

46

Page 54: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored & armored

20 AWG • 0.52 mm2 / 300V

APPLICATIONSBOSTMARINE Type X 300 volt cables are suitable for use in commercial marine applica-tions where flame retardant cables having excellent physical and electrical properties arerequired. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 andthe Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognizedtesting laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 300volts. Type X cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.Optional outer PVC sheath available upon request.

FEATURES• IEEE STANDARD 45 (1998)

• IEEE STANDARD 1580 (2001)

• UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION1. CONDUCTORS

Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table onreverse.

2. INSULATION Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are ratedVW1. Thickness as shown in tables on the reverse.

3. PAIR SHIELDAluminum / polyester tape with tinned copper drain wire to provide 100% coverageover the twisted pair, covered with a polyester tape.

4. JACKETFlame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core(covered with a polyester separator tape) and complies with Type T polyvinyl chlorideas required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGSMeets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALSETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance withIEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirementsof IEC 60092-3 for 0.6/1 kV.American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).Transport Canada Approved cables are available.Manufactured to Draka Cableteq USA Specifying Standard J-511

DU

SA

_X09

_100

5

CustRef X-09

2

1

4

3

DrakaMarine Shipboard Cables

DR

AK

AM

OG

BO

STM

AR

INE

47

Page 55: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTMARINE TYPE X SIGNAL CABLEindiv. & overall shielded twisted pair / unarmored20 AWG • 0.52 mm2 / 300V

Insulation Jacket Cable Diameter Cable WeightTPC Part Number of Stranding Thickness Thickness (nominal) (approximate)Cable Type Number Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km

TP20(IS)XT-1 036602 1 7/12.1 0.025 • 0.64 0.045 • 1.14 0.28 • 7.1 36 • 54TP20(IS-OS)XT-2 036603 2 7/12.1 0.025 • 0.64 0.045 • 1.14 0.41 • 10.4 64 • 95TP20(IS-OS)XT-3 036604 3 7/12.1 0.025 • 0.64 0.045 • 1.14 0.43 • 10.9 80 • 119TP20(IS-OS)XT-4 036605 4 7/12.1 0.025 • 0.64 0.045 • 1.14 0.48 • 12.2 97 • 144TP20(IS-OS)XT-5 036606 5 7/12.1 0.025 • 0.64 0.060 • 1.52 0.55 • 14.0 132 • 196TP20(IS-OS)XT-6 036607 6 7/12.1 0.025 • 0.64 0.060 • 1.52 0.60 • 15.2 152 • 226TP20(IS-OS)XT-7 036608 7 7/12.1 0.025 • 0.64 0.060 • 1.52 0.60 • 15.2 164 • 244TP20(IS-OS)XT-8 036609 8 7/12.1 0.025 • 0.64 0.060 • 1.52 0.65 • 16.5 185 • 275TP20(IS-OS)XT-9 036610 9 7/12.1 0.025 • 0.64 0.060 • 1.52 0.69 • 17.5 204 • 303TP20(IS-OS)XT-10 036611 10 7/12.1 0.025 • 0.64 0.060 • 1.52 0.75 • 19.1 226 • 336TP20(IS-OS)XT-11 036612 11 7/12.1 0.025 • 0.64 0.060 • 1.52 0.78 • 19.8 242 • 360TP20(IS-OS)XT-12 036613 12 7/12.1 0.025 • 0.64 0.060 • 1.52 0.78 • 19.8 256 • 381TP20(IS-OS)XT-13 036614 13 7/12.1 0.025 • 0.64 0.060 • 1.52 0.82 • 20.8 275 • 409TP20(IS-OS)XT-14 036615 14 7/12.1 0.025 • 0.64 0.060 • 1.52 0.82 • 20.8 289 • 430TP20(IS-OS)XT-15 036616 15 7/12.1 0.025 • 0.64 0.080 • 2.03 0.90 • 22.9 346 • 515TP20(IS-OS)XT-16 036617 16 7/12.1 0.025 • 0.64 0.080 • 2.03 0.90 • 22.9 359 • 534TP20(IS-OS)XT-17 036618 17 7/12.1 0.025 • 0.64 0.080 • 2.03 0.95 • 24.1 381 • 566TP20(IS-OS)XT-18 036619 18 7/12.1 0.025 • 0.64 0.080 • 2.03 0.95 • 24.1 395 • 587TP20(IS-OS)XT-19 036620 19 7/12.1 0.025 • 0.64 0.080 • 2.03 0.95 • 24.1 408 • 608TP20(IS-OS)XT-20 036621 20 7/12.1 0.025 • 0.64 0.080 • 2.03 0.99 • 25.1 429 • 638TP20(IS-OS)XT-21 036622 21 7/12.1 0.025 • 0.64 0.080 • 2.03 0.99 • 25.1 444 • 661TP20(IS-OS)XT-22 036623 22 7/12.1 0.025 • 0.64 0.080 • 2.03 1.04 • 26.4 466 • 694

indiv. & overall shielded twisted pair / aluminum or bronze armored20 AWG • 0.52 mm2 / 300V

Insulation Jacket Armored Aluminum arm. Bronze arm.TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable WeightCable Type Number* Pairs Type in • mm in • mm in • mm Lbs/mft • Kg/km Lbs/mft • Kg/km

TP20(IS)XT-1 036602* 1 7/12.1 0.025 • 0.64 0.045 • 1.14 0.335 • 8.5 54 • 80 95 • 141TP20(IS-OS)XT-2 036603* 2 7/12.1 0.025 • 0.64 0.045 • 1.14 0.465 • 11.8 89 • 132 147 • 219TP20(IS-OS)XT-3 036604* 3 7/12.1 0.025 • 0.64 0.045 • 1.14 0.485 • 12.3 106 • 158 167 • 248TP20(IS-OS)XT-4 036605* 4 7/12.1 0.025 • 0.64 0.045 • 1.14 0.535 • 13.6 126 • 187 194 • 289TP20(IS-OS)XT-5 036606* 5 7/12.1 0.025 • 0.64 0.060 • 1.52 0.605 • 15.4 165 • 246 242 • 360TP20(IS-OS)XT-6 036607* 6 7/12.1 0.025 • 0.64 0.060 • 1.52 0.655 • 16.6 188 • 280 271 • 403TP20(IS-OS)XT-7 036608* 7 7/12.1 0.025 • 0.64 0.060 • 1.52 0.655 • 16.6 200 • 298 283 • 421TP20(IS-OS)XT-8 036609* 8 7/12.1 0.025 • 0.64 0.060 • 1.52 0.705 • 17.9 224 • 333 314 • 467TP20(IS-OS)XT-9 036610* 9 7/12.1 0.025 • 0.64 0.060 • 1.52 0.745 • 18.9 245 • 365 340 • 506TP20(IS-OS)XT-10 036611* 10 7/12.1 0.025 • 0.64 0.060 • 1.52 0.805 • 20.4 271 • 403 374 • 556TP20(IS-OS)XT-11 036612* 11 7/12.1 0.025 • 0.64 0.060 • 1.52 0.835 • 21.2 288 • 429 396 • 589TP20(IS-OS)XT-12 036613* 12 7/12.1 0.025 • 0.64 0.060 • 1.52 0.835 • 21.2 302 • 449 410 • 610TP20(IS-OS)XT-13 036614* 13 7/12.1 0.025 • 0.64 0.060 • 1.52 0.875 • 22.2 324 • 482 436 • 649TP20(IS-OS)XT-14 036615* 14 7/12.1 0.025 • 0.64 0.060 • 1.52 0.875 • 22.2 338 • 503 450 • 670TP20(IS-OS)XT-15 036616* 15 7/12.1 0.025 • 0.64 0.080 • 2.03 0.955 • 24.3 399 • 594 522 • 777TP20(IS-OS)XT-16 036617* 16 7/12.1 0.025 • 0.64 0.080 • 2.03 0.955 • 24.3 412 • 613 535 • 796TP20(IS-OS)XT-17 036618* 17 7/12.1 0.025 • 0.64 0.080 • 2.03 1.005 • 25.5 437 • 650 567 • 844TP20(IS-OS)XT-18 036619* 18 7/12.1 0.025 • 0.64 0.080 • 2.03 1.005 • 25.5 451 • 671 584 • 869TP20(IS-OS)XT-19 036620* 19 7/12.1 0.025 • 0.64 0.080 • 2.03 1.005 • 25.5 464 • 690 594 • 884TP20(IS-OS)XT-20 036621* 20 7/12.1 0.025 • 0.64 0.080 • 2.03 1.045 • 26.5 487 • 725 622 • 926TP20(IS-OS)XT-21 036622* 21 7/12.1 0.025 • 0.64 0.080 • 2.03 1.045 • 26.5 502 • 747 637 • 948TP20(IS-OS)XT-22 036623* 22 7/12.1 0.025 • 0.64 0.080 • 2.03 1.095 • 27.8 527 • 784 669 • 995

*NOTE: For aluminum armored versions, add an A (ex. 036602A). For bronze armored versions, add a B (ex. 036602B). This information is provided for reference only, please consult the factory or your representative to confirm all engineering information. This information is not meant to replace the information in the appropriate and applicable standard or code.

CustRef X-10Draka USA Distribution • 1610 Greens Road / Suite 200 • Houston, TX 77032 • 281-209-1070 • 888-354-2225 • 281-209-3857 fax • www.drakausa.com

48

Page 56: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 17 of 62

Multi-conductor / armored and sheathedTYPE P CONTROL CABLE600V or 0.6/1kV12 & 10 AWG

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).They are suitable for use in Class I, Division I and Zone Iapplications (armored & sheathed) and meet the crushand impact resistance requirements (C&IR) of UL 2225.

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an unarmored version.

31 2 4 5

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.4. Armor Braided bronze in accordance with IEEE 1580 (2001).5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene

as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

DUSA_MOG17_0807

49

Page 57: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 18 of 62

BOSTRIG™ TYPE P CONTROL CABLE 600V or 0.6/1kV

DUSA_MOG18_0807

12 AWG • 3.08 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km C12PNBS-2 026300 2 .030 • 0.76 .060 • 1.5 .605 • 15.4 250 • 372C12PNBS-3 026301 3 .030 • 0.76 .060 • 1.5 .620 • 15.8 285 • 424C12PNBS-4 026302 4 .030 • 0.76 .060 • 1.5 .665 • 16.9 325 • 484C12PNBS-5 026303 5 .030 • 0.76 .060 • 1.5 .710 • 18.0 370 • 551C12PNBS-6 026304 6 .030 • 0.76 .060 • 1.5 .750 • 19.1 415 • 618C12PNBS-7 026305 7 .030 • 0.76 .060 • 1.5 .750 • 19.1 435 • 647C12PNBS-8 026306 8 .030 • 0.76 .060 • 1.5 .800 • 20.3 485 • 722C12PNBS-10 026307 10 .030 • 0.76 .080 • 2.0 .940 • 23.9 620 • 923C12PNBS-12 026308 12 .030 • 0.76 .080 • 2.0 .965 • 24.5 680 • 1012C12PNBS-16 026309 16 .030 • 0.76 .080 • 2.0 1.085 • 27.6 870 • 1295C12PNBS-20 026310 20 .030 • 0.76 .080 • 2.0 1.175 • 29.9 1020 • 1518C12PNBS-24 026311 24 .030 • 0.76 .080 • 2.0 1.280 • 32.5 1180 • 1756C12PNBS-30 026312 30 .030 • 0.76 .080 • 2.0 1.340 • 34.0 1370 • 2039C12PNBS-37 026313 37 .030 • 0.76 .110 • 2.8 1.490 • 37.9 1685 • 2508C12PNBS-44 026314 44 .030 • 0.76 .110 • 2.8 1.640 • 41.7 1955 • 2909C12PNBS-60 026315 60 .030 • 0.76 .125 • 3.2 1.875 • 47.6 2630 • 3914C12PNBS-91 026316 91 .030 • 0.76 .125 • 3.2 2.180 • 55.4 3670 • 5462

10 AWG • 5.53 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km C10PNBS-2 026317 2 .030 • 0.76 .060 • 1.5 .670 • 17.0 315 • 469C10PNBS-3 026318 3 .030 • 0.76 .060 • 1.5 .695 • 17.7 370 • 551C10PNBS-4 026319 4 .030 • 0.76 .060 • 1.5 .750 • 19.1 430 • 640C10PNBS-5 026320 5 .030 • 0.76 .060 • 1.5 .820 • 20.8 500 • 744C10PNBS-6 026321 6 .030 • 0.76 .080 • 2.0 .895 • 22.7 600 • 893C10PNBS-7 026322 7 .030 • 0.76 .080 • 2.0 .895 • 22.7 640 • 952C10PNBS-8 026323 8 .030 • 0.76 .080 • 2.0 .950 • 24.1 710 • 1057C100PNBS-10 026324 10 .030 • 0.76 .080 • 2.0 1.112 • 28.5 910 • 1354

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions throughrelays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

multi-conductor / armored and sheathed12 & 10 AWG / 600V or 0.6/1kV

Table 3

Three Conductor Cable, four Conductor

Cables with three Current Carrying

Conductors 45ºC Ambient

Conductor SizeGauge CMA mm2 95ºC 100ºC 110ºC

12 6,503 3.30 26 31 3310 10,908 5.53 37 41 44

Table 4

Cables with more than four Current Carrying Conductors

No of Conductors Derating Factor from 3Conductor Ampacity

4-6 0.87-9 0.7

10-20 0.521-30 0.4531-40 0.4041-60 0.35

61 and greater 0.3050

Page 58: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 41 of 62

Multi-conductor / unarmoredTYPE P CONTROL CABLE600V or 0.6/1kV12 & 10 AWG

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored andsheathed version.

31 2

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

DUSA_MOG41_0807

51

Page 59: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 42 of 62

BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV

12 AWG • 3.08 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km C12PN-2 026224 2 .030 • 0.76 .060 • 1.5 .425 • 10.8 100 • 149C12PN-3 026225 3 .030 • 0.76 .060 • 1.5 .440 • 11.2 135 • 201C12PN-4 026226 4 .030 • 0.76 .060 • 1.5 .475 • 12.1 155 • 231C12PN-5 026227 5 .030 • 0.76 .060 • 1.5 .525 • 13.3 190 • 283C12PN-6 026228 6 .030 • 0.76 .060 • 1.5 .570 • 14.5 220 • 327C12PN-7 026229 7 .030 • 0.76 .060 • 1.5 .570 • 14.5 245 • 365C12PN-8 026230 8 .030 • 0.76 .060 • 1.5 .620 • 15.6 280 • 417C12PN-10 026231 10 .030 • 0.76 .060 • 1.5 .720 • 18.3 355 • 528C12PN-12 026232 12 .030 • 0.76 .060 • 1.5 .745 • 18.9 400 • 595C12PN-16 026233 16 .030 • 0.76 .080 • 2.0 .865 • 22.0 550 • 818C12PN-20 026234 20 .030 • 0.76 .080 • 2.0 .955 • 24.3 680 • 1012C12PN-24 026235 24 .030 • 0.76 .080 • 2.0 1.060 • 26.9 795 • 1183C12PN-30 026236 30 .030 • 0.76 .080 • 2.0 1.120 • 28.5 955 • 1421C12PN-37 026237 37 .030 • 0.76 .080 • 2.0 1.210 • 30.7 1140 • 1697C12PN-44 026238 44 .030 • 0.76 .080 • 2.0 1.355 • 34.4 1390 • 2069C12PN-60 026239 60 .030 • 0.76 .110 • 2.8 1.565 • 39.8 1880 • 2798C12PN-91 026240 91 .030 • 0.76 .125 • 3.2 1.880 • 47.8 2800 • 4167

10 AWG • 5.53 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km C10PN-2 026241 2 .030 • 0.76 .060 • 1.5 .490 • 12.5 115 • 171C10PN-3 026242 3 .030 • 0.76 .060 • 1.5 .520 • 13.2 200 • 298C10PN-4 026243 4 .030 • 0.76 .060 • 1.5 .565 • 14.4 240 • 357C10PN-5 026244 5 .030 • 0.76 .060 • 1.5 .620 • 15.8 295 • 439C10PN-6 026245 6 .030 • 0.76 .060 • 1.5 .675 • 17.2 350 • 521C10PN-7 026246 7 .030 • 0.76 .060 • 1.5 .675 • 17.2 390 • 580C10PN-8 026247 8 .030 • 0.76 .060 • 1.5 .730 • 18.5 445 • 662C10PN-10 026248 10 .030 • 0.76 .080 • 2.0 .895 • 22.7 590 • 878

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions throughrelays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

multi-conductor / unarmored12 & 10 AWG / 600V or 0.6/1kV

DUSA_MOG42_0807

Table 3

Three Conductor Cable, four Conductor

Cables with three Current Carrying

Conductors 45ºC Ambient

Conductor SizeGauge CMA mm2 95ºC 100ºC 110ºC

12 6,503 3.30 26 31 3310 10,908 5.53 37 41 44

Table 4

Cables with more than four Current Carrying Conductors

No of Conductors Derating Factor from 3Conductor Ampacity

4-6 0.87-9 0.7

10-20 0.521-30 0.4531-40 0.4041-60 0.35

61 and greater 0.30

52

Page 60: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 39 of 62

Multi-conductor / unarmoredTYPE P CONTROL CABLE600V or 0.6/1kV14 AWG

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored andsheathed version.

31 2

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown in tables on oppposite page.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

DUSA_MOG39_0807

53

Page 61: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 40 of 62

BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km

C14PN-2 026207 2 .030 • 0.76 .060 • 1.5 .380 • 6.7 77 • 115

C14PN-3 026208 3 .030 • 0.76 .060 • 1.5 .390 • 9.9 100 • 149

C14PN-4 026209 4 .030 • 0.76 .060 • 1.5 .430 • 10.9 115 • 171

C14PN-5 026210 5 .030 • 0.76 .060 • 1.5 .475 • 12.1 147 • 218

C14PN-6 026211 6 .030 • 0.76 .060 • 1.5 .515 • 13.1 165 • 246

C14PN-7 026212 7 .030 • 0.76 .060 • 1.5 .515 • 13.1 180 • 268

C14PN-8 026213 8 .030 • 0.76 .060 • 1.5 .560 • 14.2 210 • 313

C14PN-10 026214 10 .030 • 0.76 .060 • 1.5 .650 • 16.5 260 • 387

C14PN-12 026215 12 .030 • 0.76 .060 • 1.5 .670 • 17.0 290 • 432

C14PN-16 026216 16 .030 • 0.76 .060 • 1.5 .740 • 18.8 375 • 558

C14PN-20 026217 20 .030 • 0.76 .060 • 1.5 .820 • 20.8 495 • 737

C14PN-24 026218 24 .030 • 0.76 .060 • 1.5 .950 • 24.1 585 • 871

C14PN-30 026219 30 .030 • 0.76 .080 • 2.0 1.005 • 25.5 695 • 1034

C14PN-37 026220 37 .030 • 0.76 .080 • 2.0 1.080 • 27.4 850 • 1265

C14PN-44 026297 44 .030 • 0.76 .080 • 2.0 1.215 • 30.9 990 • 1473

C14PN-60 026298 60 .030 • 0.76 .080 • 2.0 1.345 • 34.2 1300 • 1935

C14PN-91 026299 91 .030 • 0.76 .080 • 2.0 1.650 • 41.9 1980 • 2947

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions throughrelays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

multi-conductor / unarmored14 AWG / 600V or 0.6/1kV • 1.94 mm2

DUSA_MOG40_0807

Table 3

Three Conductor Cable, four Conductor

Cables with three Current Carrying

Conductors 45ºC Ambient

Conductor SizeGauge CMA mm2 95ºC 100ºC 110ºC

14 4,106 2.08 20 25 27

Table 4

Cables with more than four Current Carrying Conductors

No of Conductors Derating Factor from 3Conductor Ampacity

4-6 0.87-9 0.7

10-20 0.521-30 0.4531-40 0.4041-60 0.35

61 and greater 0.30

54

Page 62: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 15 of 62

Multi-conductor / armored and sheathedTYPE P CONTROL CABLE600V or 0.6/1kV14 AWG

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).They are suitable for use in Class I, Division I and Zone Iapplications (armored & sheathed) and meet the crushand impact resistance requirements (C&IR) of UL 2225.

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an unarmored version.

31 2 4 5

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.4. Armor Braided bronze in accordance with IEEE 1580 (2001).5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene

as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

DUSA_MOG15_0807

55

Page 63: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 16 of 62

BOSTRIG™ TYPE P CONTROL CABLE 600V or 0.6/1kV

DUSA_MOG16_0807

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km

C14PNBS-2 026283 2 .030 • 0.76 .060 • 1.5 .560 • 14.2 205 • 305

C14PNBS-3 026284 3 .030 • 0.76 .060 • 1.5 .575 • 14.6 240 • 357

C14PNBS-4 026285 4 .030 • 0.76 .060 • 1.5 .620 • 15.8 275 • 409

C14PNBS-5 026286 5 .030 • 0.76 .060 • 1.5 .660 • 16.8 305 • 454

C14PNBS-6 026287 6 .030 • 0.76 .060 • 1.5 .700 • 17.8 340 • 506

C14PNBS-7 026288 7 .030 • 0.76 .060 • 1.5 .700 • 17.8 355 • 528

C14PNBS-8 026289 8 .030 • 0.76 .060 • 1.5 .740 • 18.8 395 • 588

C14PNBS-10 026290 10 .030 • 0.76 .060 • 1.5 .860 • 21.8 500 • 744

C14PNBS-12 026291 12 .030 • 0.76 .060 • 1.5 .890 • 22.6 550 • 818

C14PNBS-16 026292 16 .030 • 0.76 .060 • 1.5 .960 • 24.4 655 • 975

C14PNBS-20 026293 20 .030 • 0.76 .060 • 1.5 1.040 • 26.4 770 • 1146

C14PNBS-24 026294 24 .030 • 0.76 .080 • 2.0 1.170 • 29.7 930 • 1384

C14PNBS-30 026295 30 .030 • 0.76 .080 • 2.0 1.225 • 31.1 1060 • 1577

C14PNBS-37 026296 37 .030 • 0.76 .080 • 2.0 1.305 • 33.2 1240 • 1845

C14PNBS-44 026297 44 .030 • 0.76 .110 • 2.8 1.495 • 38.0 1510 • 2247

C14PNBS-60 026298 60 .030 • 0.76 .110 • 2.8 1.625 • 41.3 1880 • 2298

C14PNBS-91 026299 91 .030 • 0.76 .115 • 2.9 1.950 • 49.5 2750 • 4093

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions throughrelays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

multi-conductor / armored and sheathed14 AWG / 600V or 0.6/1kV • 1.94 mm2

Table 3

Three Conductor Cable, four Conductor

Cables with three Current Carrying

Conductors 45ºC Ambient

Conductor SizeGauge CMA mm2 95ºC 100ºC 110ºC

14 4,106 2.08 20 25 27

Table 4

Cables with 4 or moreCurrent Carrying Conductors

No of Conductors Derating Factor from 3Conductor Ampacity

4-6 0.87-9 0.7

10-20 0.521-30 0.4531-40 0.4041-60 0.35

61 and greater 0.30

56

Page 64: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 37 of 62

Multi-conductor / unarmoredTYPE P CONTROL CABLE600V or 0.6/1kV16 AWG

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored andsheathed version.

31 2

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

DUSA_MOG37_0807

57

Page 65: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 38 of 62

BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km

C16PN-2 026190 2 .030 • 0.76 .060 • 1.5 .355 • 9.0 65 • 97

C16PN-3 026191 3 .030 • 0.76 .060 • 1.5 .370 • 9.4 80 • 119

C16PN-4 026192 4 .030 • 0.76 .060 • 1.5 .400 • 10.2 95 • 141

C16PN-5 026193 5 .030 • 0.76 .060 • 1.5 .440 • 11.2 115 • 171

C16PN-6 026194 6 .030 • 0.76 .060 • 1.5 .475 • 12.1 135 • 201

C16PN-7 026195 7 .030 • 0.76 .060 • 1.5 .475 • 12.1 145 • 216

C16PN-8 026196 8 .030 • 0.76 .060 • 1.5 .540 • 13.7 160 • 238

C16PN-10 026197 10 .030 • 0.76 .060 • 1.5 .595 • 15.1 200 • 298

C16PN-12 026198 12 .030 • 0.76 .060 • 1.5 .610 • 15.5 225 • 335

C16PN-16 026199 16 .030 • 0.76 .060 • 1.5 .675 • 17.2 285 • 424

C16PN-20 026200 20 .030 • 0.76 .060 • 1.5 .745 • 18.9 350 • 521

C16PN-24 026201 24 .030 • 0.76 .060 • 1.5 .840 • 21.3 440 • 655

C16PN-30 026202 30 .030 • 0.76 .080 • 2.0 .915 • 23.2 520 • 774

C16PN-37 026203 37 .030 • 0.76 .080 • 2.0 .985 • 25.0 625 • 930

C16PN-44 026204 44 .030 • 0.76 .080 • 2.0 1.100 • 27.9 735 • 1094

C16PN-60 026205 60 .030 • 0.76 .080 • 2.0 1.220 • 31.0 960 • 1429

C16PN-91 026206 91 .030 • 0.76 .080 • 2.0 1.480 • 37.6 1470 • 2188

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions throughrelays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

multi-conductor / unarmored16 AWG / 600V or 0.6/1kV • 1.23 mm2

DUSA_MOG38_0807

Table 3

Three Conductor Cable, four Conductor

Cables with three Current Carrying

Conductors 45ºC Ambient

Conductor SizeGauge CMA mm2 95ºC 100ºC 110ºC

16 2,061 1.32 16 17 18

Table 4

Cables with more than four Current Carrying Conductors

No of Conductors Derating Factor from 3Conductor Ampacity

4-6 0.87-9 0.7

10-20 0.521-30 0.4531-40 0.4041-60 0.35

61 and greater 0.30

58

Page 66: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 13 of 62

Multi-conductor / armored and sheathedTYPE P CONTROL CABLE600V or 0.6/1kV16 AWG

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).They are suitable for use in Class I, Division I and Zone Iapplications (armored & sheathed) and meet the crushand impact resistance requirements (C&IR) of UL 2225.

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an unarmored version.

31 2 4 5

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.4. Armor Braided bronze in accordance with IEEE 1580 (2001).5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene

as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

DUSA_MOG13_0807

59

Page 67: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 14 of 62

BOSTRIG™ TYPE P CONTROL CABLE 600V or 0.6/1kV

DUSA_MOG14_0807

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km

C16PNBS-2 026266 2 .030 • 0.76 .060 • 1.5 .535 • 13.6 190 • 283

C16PNBS-3 026267 3 .030 • 0.76 .060 • 1.5 .545 • 13.8 205 • 305

C16PNBS-4 0262668 4 .030 • 0.76 .060 • 1.5 .590 • 15.0 235 • 350

C16PNBS-5 026269 5 .030 • 0.76 .060 • 1.5 .620 • 15.8 265 • 394

C16PNBS-6 026270 6 .030 • 0.76 .060 • 1.5 .655 • 16.6 295 • 439

C16PNBS-7 026271 7 .030 • 0.76 .060 • 1.5 .655 • 16.6 300 • 446

C16PNBS-8 026272 8 .030 • 0.76 .060 • 1.5 .720 • 18.3 340 • 506

C16PNBS-10 026273 10 .030 • 0.76 .060 • 1.5 .775 • 19.7 400 •595

C16PNBS-12 026274 12 .030 • 0.76 .060 • 1.5 .790 • 20.1 430 • 640

C16PNBS-16 026275 16 .030 • 0.76 .080 • 2.0 .895 • 22.7 545 • 811

C16PNBS-20 026276 20 .030 • 0.76 .080 • 2.0 .965 • 24.5 635 • 945

C16PNBS-24 026277 24 .030 • 0.76 .080 • 2.0 1.050 • 26.7 755 •1124

C16PNBS-30 026278 30 .030 • 0.76 .080 • 2.0 1.135 • 28.8 865 • 1287

C16PNBS-37 026279 37 .030 • 0.76 .080 • 2.0 1.205 • 30.6 995 • 1480

C16PNBS-44 026280 44 .030 • 0.76 .080 • 2.0 1.320 • 33.5 1125 • 1674

C16PNBS-60 026281 60 .030 • 0.76 .110 • 2.8 1.500 • 38.1 1495 • 2225

C16PNBS-91 026282 91 .030 • 0.76 .110 • 2.8 1.770 • 45.0 2100 • 3125

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions throughrelays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

multi-conductor / armored and sheathed16 AWG / 600V or 0.6/1kV • 1.23 mm2

Table 3

Three Conductor Cable, four Conductor

Cables with three Current Carrying

Conductors 45ºC Ambient

Conductor SizeGauge CMA mm2 95ºC 100ºC 110ºC

16 2,601 1.32 16 17 18

Table 4

Cables with 4 or more Current Carrying Conductors

No of Conductors Derating Factor from 3Conductor Ampacity

4-6 0.87-9 0.7

10-20 0.521-30 0.4531-40 0.4041-60 0.35

61 and greater 0.30

60

Page 68: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 35 of 62

Multi-conductor / unarmoredTYPE P CONTROL CABLE600V or 0.6/1kV18 AWG

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored andsheathed version.

31 2

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

DUSA_MOG35_0807

61

Page 69: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 36 of 62

BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV

Insulation Jacket Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km

C18PN-2 026173 2 .030 • 0.76 .060 • 1.5 .340 • 8.6 55 • 82

C18PN-3 026174 3 .030 • 0.76 .060 • 1.5 .360 • 9.1 70 • 104

C18PN-4 026175 4 .030 • 0.76 .060 • 1.5 .390 • 9.9 85 • 127

C18PN-5 026176 5 .030 • 0.76 .060 • 1.5 .425 • 10.8 100 • 149

C18PN-6 026177 6 .030 • 0.76 .060 • 1.5 .460 • 11.7 120 • 179

C18PN-7 026178 7 .030 • 0.76 .060 • 1.5 .460 • 11.7 130 • 193

C18PN-8 026179 8 .030 • 0.76 .060 • 1.5 .490 • 12.5 140 • 208

C18PN-10 026180 10 .030 • 0.76 .060 • 1.5 .570 • 14.5 175 • 260

C18PN-12 026181 12 .030 • 0.76 .060 • 1.5 .585 • 14.9 195 • 290

C18PN-16 026182 16 .030 • 0.76 .060 • 1.5 .660 • 16.8 250 • 372

C18PN-20 026183 20 .030 • 0.76 .060 • 1.5 .715 • 18.2 305 • 454

C18PN-24 026184 24 .030 • 0.76 .060 • 1.5 .790 • 20.1 355 • 528

C18PN-30 026185 30 .030 • 0.76 .080 • 2.0 .875 • 22.2 455 • 677

C18PN-37 026186 37 .030 • 0.76 .080 • 2.0 .940 • 23.9 545 • 811

C18PN-44 026187 44 .030 • 0.76 .080 • 2.0 1.055 • 26.8 640 • 952

C18PN-60 026188 60 .030 • 0.76 .080 • 2.0 1.165 • 29.6 835 • 1243

C18PN-91 026189 91 .030 • 0.76 .080 • 2.0 1.390 • 35.3 1220 • 1816

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions throughrelays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

multi-conductor / unarmored18 AWG / 600V or 0.6/1kV • 0.96 mm2

DUSA_MOG36_0807

Table 3

Three Conductor Cable, four Conductor

Cables with three Current Carrying

Conductors 45ºC Ambient

Conductor SizeGauge CMA mm2 95ºC 100ºC 110ºC

18 1,620 0.82 11 12 13

Table 4

Cables with more than four Current Carrying Conductors

No of Conductors Derating Factor from 3Conductor Ampacity

4-6 0.87-9 0.7

10-20 0.521-30 0.4531-40 0.4041-60 0.35

61 and greater 0.30

62

Page 70: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 11 of 62

Multi-conductor / armored and sheathedTYPE P CONTROL CABLE600V or 0.6/1kV18 AWG

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).They are suitable for use in Class I, Division I and Zone Iapplications (armored & sheathed) and meet the crushand impact resistance requirements (C&IR) of UL 2225.

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an unarmored version.

31 2 4 5

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.4. Armor Braided bronze in accordance with IEEE 1580 (2001).5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene

as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

DUSA_MOG11_0807

63

Page 71: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 12 of 62

BOSTRIG™ TYPE P CONTROL CABLE 600V or 0.6/1kV

DUSA_MOG12_0807

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km

C18PNBS-2 026249 2 .030 • 0.76 .060 • 1.5 .515 • 13.1 180 • 268

C18PNBS-3 026250 3 .030 • 0.76 .060 • 1.5 .540 • 13.7 200 • 298

C18PNBS-4 026251 4 .030 • 0.76 .060 • 1.5 .575 • 14.6 225 • 335

C18PNBS-5 026252 5 .030 • 0.76 .060 • 1.5 .605 • 15.4 250 • 372

C18PNBS-6 026253 6 .030 • 0.76 .060 • 1.5 .640 • 16.3 275 • 409

C18PNBS-7 026254 7 .030 • 0.76 .060 • 1.5 .640 • 16.3 285 • 424

C18PNBS-8 026255 8 .030 • 0.76 .060 • 1.5 .670 • 17.1 310 • 461

C18PNBS-10 026256 10 .030 • 0.76 .060 • 1.5 .750 • 19.1 365 • 543

C18PNBS-12 026257 12 .030 • 0.76 .060 • 1.5 .765 • 19.1 365 • 543

C18PNBS-16 026258 16 .030 • 0.76 .080 • 2.0 .885 • 22.5 500 • 744

C18PNBS-20 026259 20 .030 • 0.76 .080 • 2.0 .935 • 23.8 580 • 863

C18PNBS-24 026260 24 .030 • 0.76 .080 • 2.0 1.010 • 25.7 655 • 975

C18PNBS-30 026261 30 .030 • 0.76 .080 • 2.0 1.100 • 27.9 790 • 1176

C18PNBS-37 026262 37 .030 • 0.76 .080 • 2.0 1.165 • 29.6 900 • 1339

C18PNBS-44 026263 44 .030 • 0.76 .080 • 2.0 1.275 • 32.4 1035 • 1540

C18PNBS-60 026264 60 .030 • 0.76 .110 • 2.8 1.445 • 36.7 1355 • 2016

C18PNBS-91 026265 91 .030 • 0.76 .110 • 2.8 1.650 • 41.9 1860 • 2768

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions throughrelays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

multi-conductor / armored and sheathed18 AWG / 600V or 0.6/1kV • 0.96 mm2

Table 3

Three Conductor Cable, four Conductor

Cables with three Current Carrying

Conductors 45ºC Ambient

Conductor SizeGauge CMA mm2 95ºC 100ºC 110ºC

18 1,620 0.82 11 12 13

Table 4

Cables with more than four Current Carrying Conductors

No of Conductors Derating Factor from 3Conductor Ampacity

4-6 0.87-9 0.7

10-20 0.521-30 0.4531-40 0.4041-60 0.35

61 and greater 0.30

64

Page 72: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG61_0807

BOSTRIG™ TYPE P-MR POWER CABLE

Bostrig Type P0807

Page 61 of 62

Single conductor / armored & sheathedand unarmored ester-based mud resistant TYPE P-MR POWER CABLE2000V4/0 AWG TO 1111 MCM

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Performance requirements of IEc 92-3.

Det Norske Veritas Type Approval Certificates E8797,E8798, E8799 and E8800.

Manufactured to BIW Specifying Standard J104

ApplicationsBostrigTM Type P Mud Resistant Cable is primarilydesigned for power, control, signal and instrumentationapplications for offshore, land rigs, marine vessels andoil and gas drilling rigs. Instead of Polychloroprene(Neoprene), they are sheathed in our proprietary elastomeric formulation which is not only mud-resistantbut qualifies as a low-smoke zero-halogen (LSZH) cablein accordance with IEEE 45 (1998), IEEE 1580 (2001)and type approved as Type M.

This mud-resistant jacket is designed for use in areaswhere ester-based drilling muds and fluids are present.These cables are listed by ETL in accordance with IEEE45 and type approved by DNV as resistant to NOVAPlus, Petrofree LE and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK606 for 56 days at 70ºC in each of the ester-basedmuds mentioned above

This product can be manufactured in an unarmored version.

Features

• Special ester-based mud-resistant jacket also provides superior resistance to oil,abrasion, moisture, sunlight, crush and impact

• Super-flexible construction• Meets IEEE 45 (1998) and IEEE 1580 (2001) for 600 and 2000 volts

Ratings

Meets all test requirements of IEEE 1580 (2001) and theflame test in IEC 60332-3, Category A.

Listed by ETL per IEEE 45 (1998), IEEE 1580 (2001), andUL 1309/CSA 245 and IEEE 45 (1998) for 2000V.

Type approved by DNV.

21 3 4

www.DrakaMOG.comSubject to change without prior notice

Construction

1. Conductors Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Armor Braided bronze in accordance with IEEE 1580 (2001).4. Sheath Flame-retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580

(2001). Thickness as shown in tables on opposite page.

65

Page 73: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG62_0807

Armored & sheathedSheath Cable Diameter Impedance Ampacity† Cable Weight

Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

SPBM2KV(HD)-4/0 026034M 4/0 • 112.6 .080 • 2.0 1.040 • 26.4 0.07 • 0.2 0.11 • 0.4 146 • 479 335 • 351 • 376 1190 • 1771

SPBM2KV(HD)-262 026035M 262 • 133.1 .080 • 2.0 1.090 • 27.7 0.06 • 0.2 0.10 • 0.3 162 • 531 382 • 407 • 436 1360 • 2024

SPBM2KV(HD)-313 026036M 313 • 158.7 .080 • 2.0 1.155 • 29.3 0.06 • 0.2 0.10 • 0.3 175 • 574 426 • 455 • 487 1580 • 2351

SPBM2KV(HD)-373 026037M 373 • 189.2 .080 • 2.0 1.225 • 31.1 0.05 • 0.2 0.10 • 0.3 189 • 620 476 • 516 • 553 1800 • 2678

SPBM2KV(HD)-444 026038M 444 • 225.2 .080 • 2.0 1.295 • 32.9 0.05 • 0.2 0.10 • 0.3 205 • 672 531 • 588 • 630 2130 • 3169

SPBM2KV(HD)-535 026039M 535 • 271.3 .110 • 2.8 1.475 • 37.5 0.04 • 0.01 0.10 • 0.3 200 • 656 596 • 630 • 675 2620 • 3899

SPBM2KV(HD)-646 026040M 646 • 327.5 .110 • 2.8 1.575 • 40.0 0.04 • 0.01 0.10 • 0.3 216 • 708 670 • 731 • 7783 3050 • 4538

SPBM2KV(HD)-777 026041M 777 • 394.2 .110 • 2.8 1.665 • 42.3 0.04 • 0.01 0.10 • 0.3 236 • 774 754 • 822 • 881 3570 • 5312

SPBM2KV(HD)-1111 026042M 1111 • 563.0 .125 • 3.2 1.990 • 48.3 0.04 • 0.01 0.10 • 0.3 257 • 843 942 • 1025 • 1098 4780 • 7113

UnarmoredSheath Cable Diameter Impedance Ampacity† Cable Weight

Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft- Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

SPM2KV(HD)-4/0 026015M 4/0 • 112.6 .105 • 2.7 .690 • 20.8 0.07 • 0.2 0.11 • 0.4 146 • 479 335 • 351 • 376 1060 • 1577

SPM2KV(HD)-262 026016M 262 • 133.1 .105 • 2.7 .820 • 22.1 0.06 • 0.2 0.10 • 0.3 162 • 531 382 • 407 • 436 1220 • 1815

SPM2KV(HD)-313 026017M 313 • 158.7 .105 • 2.7 .935 • 23.8 0.06 • 0.2 0.10 • 0.3 175 • 574 426 • 455 • 487 1430 • 2128

SPM2KV(HD)-373 026018M 373 • 189.2 .105 • 2.7 1.005 • 25.5 0.05 • 0.2 0.10 • 0.3 189 • 620 476 • 516 • 553 1640 • 2440

SPM2KV(HD)-444 026019M 444 • 225.2 .105 • 2.7 1.075 • 27.3 0.05 • 0.2 0.10 • 0.3 205 • 672 531 • 588 • 630 1940 • 2887

SPM2KV(HD)-535 026020M 535 • 271.3 .120 • 3.1 1.195 • 30.4 0.04 • 0.1 0.10 • 0.3 200 • 656 596 • 630 • 675 2370 • 3527

SPM2KV(HD)-646 026021M 646 • 327.5 .120 • 3.1 1.295 • 32.9 0.04 • 0.1 0.10 • 0.3 216 • 708 670 • 731 • 783 2800 • 4166

SPM2KV(HD)-777 026022M 777 • 394.2 .120 • 3.1 1.385 • 35.2 0.04 • 0.1 0.10 • 0.3 236 • 774 754 • 822 • 881 3300 • 4910

SPM2KV(HD)-1111 026023M 1111 • 563.0 .120 • 3.1 1.595 • 40.5 0.04 • 0.1 0.10 • 0.3 257 • 843 942 • 1025 • 1098 4500 • 6696

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.†Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 - 1OOºC values based on IEEE-45 Table 25 - 11 O’C values based on IEEE-45Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 62 of 62

BOSTRIG™ TYPE P-MR POWER CABLE

single conductor / armored & sheathed and unarmored4/0 AWG to 1111 MCM / 2000V

66

Page 74: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTRIG™ TYPE P POWER CABLE 600V OR 0.6/1kV & 2000V

Bostrig Type P0807

Page 25 of 62

Construction

1. Conductor Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001). Thickenessas shown in tables on opposite page.

Single conductor / unarmoredTYPE P POWER CABLE600V or 0.6/1kV & 2000V18 AWG to 1111 MCM

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J104

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored andsheathed version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight,mud, crush and impact

• Super-flexible at 4/0 AWG and larger• Meets IEEE standards for 600 & 2000V / IEC standards

for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and theflame test in IEC 60332-3, Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245and IEEE 45 (1998) for 600V & 2000V.

1 2

www.DrakaMOG.comSubject to change without prior notice DUSA_MOG25_0807

67

Page 75: Prysmian Draka - Marine & Offshore LV HV Cables

600V or 600/1000VSheath Cable Diameter Impedance Calculated Ampacity† Cable Weight

Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

SP-18 026000 18 .030 • 0.76 .111 • 2.8 6.4 • 21.0 0.18 • 0.6 58 • 190 16 • 16 • 17 11 •16

SP-16 026001 16 .030 • 0.76 .119 • 3.0 4.5 • 14.8 0.18 • 0.6 65 • 213 20 • 23 • 25 13 • 19

SP-14 026002 14 .030 • 0.76 .133 • 3.4 2.9 • 9.5 0.16 • 0.5 77 • 253 29 • 37 • 39 18 • 27

SP-12 026004 12 .030 • 0.76 .151 • 3.8 1.9 • 6.2 0.15 • 0.5 90 • 295 38 • 45 • 49 28 • 42

SP-10 026004 10 .030 • 0.76 .180 • 4.6 1.2 • 3.9 0.14 • 0.5 107 • 351 51 • 58 • 61 44 • 65

SP-8 026005 8 • 8.4 .045 • 1.1 .233 • 5.9 0.7 • 2.3 0.14 • 0.5 95 • 311 67 • 72 • 77 69 • 103

SP-6 026006 6 • 13.3 .045 • 1.1 .290 • 7.4 0.5 • 1.6 0.12 • 0.4 126 • 413 90 • 96 • 103 103 • 153

SP-5 026007 5 • 18.6 .045 • 1.1 .335 • 8.5 0.3 • 1.6 0.12 • 0.4 140 • 459 111 • 109 • 117 145 • 216

SP-4 026008 4 • 21.5 .045 • 1.11 .353 • 9.0 0.3 • 1.6 0.12 • 0.4 153 • 502 122 • 128 • 137 171 • 254

SP-3 026009 3 • 27.2 .045 • 1.1 .380 • 9.7 0.2 • 0.7 0.11 • 0.4 173 • 567 142 • 146 • 156 200 • 298

SP-2 026010 2 • 33.7 .045 • 1.1 .423 • 10.7 0.2 • 0.7 0.11 • 0.4 187 • 613 162 • 169 • 181 231 • 344

SP-1 026011 1 • 46.1 .055 • 1.4 .493 • 12.5 0.1 • 0.3 0.11 • 0.4 178 • 584 197 • 194 • 208 348 • 518

SP-1/0 026012 1/0 • 56.3 .055 • 1.4 .524 • 13.3 0.1 • 0.3 0.11 • 0.4 190 • 623 223 • 227 • 243 414 • 618

SP-2/0 026013 2/0 • 67.6 .055 • 1.4 .578 • 14.7 0.09 • 0.3 0.10 • 0.3 212 • 695 250 • 262 • 281 476 • 708

SP-3/0 026014 3/0 • 92.1 .055 • 1.4 .659 • 16.7 0.08 • 0.3 0.10 • 0.3 245 • 804 304 • 300 • 321 671 • 999

2000VSheath Cable Diameter Impedance Calculated Ampacity† Cable Weight

Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

SP2KV-8 030477 8 0.055 • 1.40 0.265 • 6.7 0.695 • 2.28 0.108 • 0.354 82 • 269 67 • 72 • 77 74 • 111

SP2KV-6 030478 6 0.055 • 1.40 0.326 • 8.3 0.442 • 1.45 0.099 • 0.324 108 • 354 90 • 96 • 103 110 • 164

SP2KV-5 030479 5 0.055 • 1.40 0.354 • 9.0 0.332 • 1.09 0.097 • 0.318 120 • 393 111 • 109 • 117 147 • 220

SP2KV-4 030480 4 0.055 • 1.40 0.38 • 9.7 0.277 • 0.91 0.095 • 0.312 131 • 430 122 • 128 • 137 170 • 254

SP2KV-3 030481 3 0.055 • 1.40 0.42 • 10.7 0.221 • 0.72 0.092 • 0.302 148 • 485 142 • 146 • 156 206 • 307

SP2KV-2 030482 2 0.055 • 1.40 0.449 • 11.4 0.176 • 0.58 0.090 • 0.295 160 • 525 162 • 169 • 181 251 • 374

SP2KV-1 030483 1 0.065 • 1.65 0.519 • 13.2 0.141 • 0.46 0.091 • 0.298 158 • 518 197 • 194 • 208 341 • 507

SP2KV-1/0 029732 1/0 0.065 • 1.65 0.549 • 13.9 0.113 • 0.37 0.089 • 0.292 168 • 551 223 • 227 • 243 405 • 603

SP2KV-2/0 027055 2/0 0.065 • 1.65 0.594 • 15.1 0.092 • 0.30 0.088 • 0.289 184 • 604 250 • 262 • 281 499 • 742

SP2KV-3/0 030484 3/0 0.065 • 1.65 0.684 • 17.4 0.075 • 0.25 0.086 • 0.282 216 • 708 304 • 300 • 321 668 • 994

SP2KV(HD)-4/0 026015 4/0 • 112.6 0.105 • 2.7 .821 • 20.9 0.07 • 0.2 0.11 • 0.4 146 • 479 344 • 351 • 376 896 • 1333

SP2KV(HD)-262 026016 262 • 133.1 0.105 • 2.7 .895 • 22.7 0.06 • 0.2 0.10 • 0.3 162 • 531 382 • 407 • 436 1035 • 1540

SP2KV(HD)-313 026017 313 • 158.7 0.105 • 2.7 .966 • 24.5 0.06 • 0.2 0.10 • 0.3 175 • 574 426 • 455 • 487 1227 • 1826

SP2KV(HD)-373 026018 373 • 189.2 0.105 • 2.7 1.033 • 26.2 0.05 • 0.2 0.10 • 0.3 189 • 620 476 • 516 • 553 1424 • 2119

SP2KV(HD)-444 026019 444 • 225.2 0.105 • 2.7 1.114 • 28.3 0.05 • 0.2 0.10 • 0.3 205 • 672 531 • 588 • 630 1707 • 2540

SP2KV(HD)-535 026020 535 • 271.3 0.120 • 3.1 1.227 • 31.2 0.04 • 0.1 0.10 • 0.3 200 • 656 596 • 630 • 675 2025 • 3014

SP2KV(HD)-646 026021 646 • 327.5 0.120 • 3.1 1.331 • 33.3 0.04 • 0.1 0.10 • 0.3 216 • 708 670 • 731 • 783 2429 • 3615

SP2KV(HD)-777 026022 777 • 394.2 0.120 • 3.1 1.424 • 36.2 0.04 • 0.1 0.10 • 0.3 236 • 774 754 • 822 • 881 2896 • 4310

SP2KV(HD)-1111 026023 1111 • 563.0 0.120 • 3.1 1.675 • 42.5 0.04 • 0.1 0.10 • 0.3 257 • 843 942 • 1025 • 1098 3946 • 5872

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.†Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 - 1OOºC values based on IEEE-45 Table 25 - 11 O’C values based on IEEE-45Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 26 of 62

BOSTRIG™ TYPE P POWER CABLE

single conductor / unarmored18 AWG to 1111 MCM / 600V or 0.6/1kV & 2000V

DUSA_MOG26_0807

68

Page 76: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTRIG™ TYPE P POWER CABLE 600V, 0.6/1kV & 2000V

Bostrig Type P0807

Page 1 of 62

Construction

1. Conductor Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Armor Braided bronze in accordance with IEEE 1580 (2001).4. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene

as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Single conductor / armored and sheathedTYPE P POWER CABLE600V or 0.6/1kV & 2000V8 AWG to 1111 MCM

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J104

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).They are suitable for use in Class I, Division I and Zone Iapplications (armored & sheathed) and meet the crushand impact resistance requirements (C&IR) of UL 2225.

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an unarmored version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight,mud, crush and impact

• Super-flexible at 4/0 AWG and larger• Meets IEEE standards for 600 & 2000V / IEC standards

for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and theflame test in IEC 60332-3, Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245and IEEE 45 (1998) for 600V & 2000V.

21 3 4

www.DrakaMOG.comSubject to change without prior notice DUSA_MOG01_0807

69

Page 77: Prysmian Draka - Marine & Offshore LV HV Cables

600VSheath Cable Diameter Impedance Calculated Ampacity† Cable Weight

Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

SPBS-8 026024 8 • 8.4 .060 • 1.5 .415 • 10.5 0.7 • 2.3 0.14 • 0.5 95 • 311 67 • 72 • 77 155 • 231

SPBS-6 026025 6 • 13.3 .060 • 1.5 .470 • 11.9 0.5 • 1.6 0.12 • 0.4 126 • 413 90 • 96 • 103 210 • 313

SPBS-5 026026 5 • 18.6 .060 • 1.5 .525 • 13.3 0.3 • 1.6 0.12 • 0.4 140 • 459 111 • 109 • 117 260 • 387

SPBS-4 026027 4 • 21.5 .060 • 1.5 .535 • 13.6 0.3 • 1.6 0.12 • 0.4 153 • 502 122 • 128 • 137 295 • 439

SPBS-3 026028 3 • 27.2 .060 • 1.5 .560 • 14.2 0.2 • 0.7 0.11 • 0.4 173 • 567 142 • 146 • 156 335 • 499

SPBS-2 026029 2 • 33.7 .060 • 1.5 .595 • 15.1 0.2 • 0.7 0.11 • 0.4 187 • 613 162 • 169 • 181 380 • 566

SPBS-1 026030 1 • 46.1 .060 • 1.5 .675 • 17.2 0.1 • 0.3 0.11 • 0.4 178 • 584 197 • 194 • 208 520 • 774

SPBS-1/0 026031 1/0 • 56.3 .060 • 1.5 .730 • 18.5 0.1 • 0.3 0.11 • 0.4 190 • 623 223 • 227 • 243 615 • 915

SPBS-2/0 026032 2/0 • 67.6 .060 • 1.5 .745 • 18.9 0.09 • 0.3 0.10 • 0.3 212 • 695 250 • 262 • 281 680 • 1012

SPBS-3/0 026033 3/0 • 92.1 .080 • 2.0 .890 • 22.6 0.08 • 0.3 0.10 • 0.3 245 • 804 304 • 300 • 321 940 • 1399

2000VSheath Cable Diameter Impedance Calculated Ampacity† Cable Weight

Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

SPBS2KV-8 036754 8 0.045 • 1.14 0.43 • 10.9 0.696 • 2.28 0.138 • 0.453 82 • 269 67 • 72 • 77 157 • 234

SPBS2KV-6 036755 6 0.045 • 1.14 0.491 • 12.5 0.442 • 1.45 0.124 • 0.407 108 • 354 90 • 96 • 103 208 • 310

SPBS2KV-5 036756 5 0.045 • 1.14 0.519 • 13.2 0.333 • 1.09 0.120 • 0.394 120 • 393 111 • 109 • 117 253 • 376

SPBS2KV-4 036757 4 0.060 • 1.52 0.575 • 14.6 0.279 • 0.92 0.120 • 0.394 131 • 430 122 • 128 • 137 299 • 445

SPBS2KV-3 036758 3 0.060 • 1.52 0.615 • 15.6 0.222 • 0.73 0.115 • 0.377 148 • 485 142 • 146 • 156 346 • 515

SPBS2KV-2 036742 2 0.060 • 1.52 0.644 • 16.4 0.178 • 0.58 0.112 • 0.367 160 • 525 162 • 169 • 181 399 • 594

SPBS2KV-1 036759 1 0.060 • 1.52 0.714 • 18.1 0.143 • 0.47 0.110 • 0.361 158 • 518 197 • 194 • 208 509 • 757

SPBS2KV-1/0 036760 1/0 0.060 • 1.52 0.744 • 18.9 0.115 • 0.38 0.108 • 0.354 168 • 551 223 • 227 • 243 581 • 865

SPBS2KV-2/0 036761 2/0 0.060 • 1.52 0.789 • 20.0 0.095 • 0.31 0.105 • 0.344 184 • 604 250 • 262 • 281 688 • 1024

SPBS2KV-3/0 027068 3/0 0.080 • 2.03 0.939 • 23.8 0.079 • 0.26 0.105 • 0.344 216 • 708 304 • 300 • 321 937 • 1395

SPBS2KV(HD)-4/0 026034 4/0 • 112.6 .080 • 2.0 1.040 • 26.4 0.07 • 0.2 0.11 • 0.4 146 • 479 344 • 351 • 376 1195 • 1778

SPBS2KV(HD)-262 026035 262 • 133.1 .080 • 2.0 1.090 • 27.7 0.06 • 0.2 0.10 • 0.3 162 • 531 382 • 407 • 436 1350 • 2009

SPBS2KV(HD)-313 026036 313 • 158.7 .080 • 2.0 1.155 • 29.3 0.06 • 0.2 0.10 • 0.3 175 • 574 426 • 455 • 487 1550 • 2307

SPBS2KV(HD)-373 026037 373 • 189.2 .080 • 2.0 1.225 • 31.1 0.05 • 0.2 0.10 • 0.3 189 • 620 476 • 516 • 553 1785 • 2656

SPBS2KV(HD)-444 026038 444 • 225.2 .080 • 2.0 1.295 • 32.9 0.05 • 0.2 0.10 • 0.3 205 • 672 531 • 588 • 630 2065 • 3073

SPBS2KV(HD)-535 026039 535 • 271.3 .110 • 2.8 1.475 • 37.5 0.04 • 0.1 0.10 • 0.3 200 • 656 596 • 630 • 675 2540 • 3780

SPBS2KV(HD)-646 026040 646 • 327.5 .110 • 2.8 1.575 • 40.0 0.04 • 0.1 0.10 • 0.3 216 • 708 670 • 731 • 783 2950 • 4390

SPBS2KV(HD)-777 026041 777 • 394.2 .110 • 2.8 1.665 • 42.3 0.04 • 0.1 0.10 • 0.3 236 • 774 754 • 822 • 881 3450 5134

SPBS2KV(HD)-1111 026042 1111 • 563.0 .125 • 3.2 1.990 • 48.3 0.04 • 0.1 0.10 • 0.3 257 • 843 942 • 1025 • 1098 4700 • 6994

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.†Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 - 1OOºC values based on IEEE-45 Table 25 - 11 O’C values based on IEEE-45Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 2 of 62

BOSTRIG™ TYPE P POWER CABLE

DUSA_MOG02_0807

single conductor / armored and sheathed8 AWG to 1111 MCM / 600V or 0.6/1kV & 2000V

70

Page 78: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 27 of 62

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

CONSTRUCTION

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored andsheathed version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Super-flexible at 4/0 AWG and larger• Meets IEEE standards for 600 & 2000V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V & 2000V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

Two conductor / unarmoredTYPE P POWER CABLE600V or 0.6/1kV8 AWG to 777 MCM

31 2

BOSTRIG™ TYPE P POWER CABLE 600V OR 0.6/1kV

DUSA_MOG27_0807

71

Page 79: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 28 of 62

BOSTRIG™ TYPE P POWER CABLE

Jacket Cable Diameter Impedance Calculated Ampacity† Cable WeightType Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

DPN-8 026043 8 • 7.57 .060 • 1.5 .590 • 15.0 0.70 • 2.3 0.12 • 0.4 95 • 312 58 • 64 • 69 210 • 313

DPN-6 026044 6 • 12.5 .060 • 1.5 .705 • 17.9 0.46 • 1.5 0.11 • 0.4 126 • 413 83 • 85 • 91 315 • 469

DPN-5 026045 5 • 18.6 .060 • 1.5 .810 • 20.6 0.33 • 1.1 0.11 • 0.4 140 • 459 95 • 101 • 108 440 • 655

DPN-4 026046 4 • 21.5 .080 • 2.0 .870 • 22.1 0.29 • 1.0 0.10 • 0.3 153 • 502 104 • 110 • 118 520 • 774

DPN-3 026047 3 • 25.6 .080 • 2.0 .920 • 23.4 0.23 • 0.8 0.10 • 0.3 173 • 567 121 • 132 • 141 605 • 900

DPN-2 026048 2 • 30.7 .080 • 2.0 .985 • 25.0 0.18 • 0.6 0.10 • 0.3 187 • 613 138 • 149 • 160 685 • 1019

DPN-1 026049 1 • 46.0 .080 • 2.0 1.150 • 29.2 0.14 • 0.5 0.09 • 0.3 178 • 584 168 • 174 • 186 975 • 1451

DPN-1/0 026050 1/0 • 56.3 .080 • 2.0 1.260 • 32.0 0.12 • 0.4 0.09 • 0.3 190 • 623 190 • 199 • 213 1150 • 1711

DPN-2/0 026051 2/0 • 66.5 .080 • 2.0 1.320 • 33.5 0.09 • 0.3 0.09 • 0.3 212 • 695 213 • 242 • 259 1285 • 1912

DPN-3/0 026052 3/0 • 92.1 .110 • 2.8 1.560 • 39.6 0.08 • 0.3 0.09 • 0.3 245 • 804 259 • 265 • 284 1860 • 2768

DPN-4/0 026053 4/0 • 112.6 .110 • 2.8 1.660 • 42.2 0.07 • 0.2 0.09 • 0.3 259 • 850 293 • 307 • 329 2215 • 3296

DPN-262 026054 262 • 133.0 .125 • 3.2 1.830 • 46.5 0.06 • 0.2 0.09 • 0.3 247 • 810 325 • 358 • 383 2605 • 3877

DPN-313 026055 313 • 158.6 .125 • 3.2 1.965 • 49.9 0.05 • 0.2 0.09 • 0.3 270 • 886 362 • 391 • 419 3035 • 4517

DPN-373 026056 373 • 189.3 .125 • 3.2 2.105 • 53.5 0.04 • 0.1 0.09 • 0.3 292 • 958 405 • 442 • 473 3615 • 5380

DPN-444 026057 444 • 225.1 .125 • 3.2 2.245 • 57.0 0.04 • 0.1 0.09 • 0.3 318 • 1043 451 • 504 • 540 4140 • 6161

DPN-535 026058 535 • 271.2 .140 • 3.6 2.4905 • 63.4 0.04 • 0.1 0.09 • 0.3 291 • 954 507 • 538 • 576 4960 • 7381

DPN-646 026059 646 • 327.5 .140 • 3.6 2.695 • 68.5 0.04 • 0.1 0.09 • 0.3 314 • 1030 570 • 632 • 677 5880 • 8750

DPN-777 026060 777 • 393.8 .140 • 3.6 2.900 • 73.7 0.03 • 0.1 0.09 • 0.3 345 • 1132 641 • 684 • 733 7030 • 10462

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.†Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 - 1OOºC values based on IEEE-45 Table 25 - 11 O’C values based on IEEE-45Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

two conductor / unarmored8 AWG to 777 MCM / 600V or 0.6/1kV

DUSA_MOG28_0807

72

Page 80: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 3 of 62

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J104

CONSTRUCTION

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.4. Armor Braided bronze in accordance with IEEE 1580 (2001).5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene

as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).They are suitable for use in Class I, Division I and Zone Iapplications (armored & sheathed) and meet the crushand impact resistance requirements (C&IR) of UL 2225.

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an unarmored version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Super-flexible at 4/0 AWG and larger• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

Two conductor / armored and sheathedTYPE P POWER CABLE600V or 0.6/1kV8 AWG to 777 MCM

31 2 4 5

BOSTRIG™ TYPE P POWER CABLE 600V OR 0.6/1kV

DUSA_MOG03_0807

73

Page 81: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 4 of 62

BOSTRIG™ TYPE P POWER CABLE

DUSA_MOG04_0807

Sheath Cable Diameter Impedance Calculated Ampacity† Cable WeightType Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

DPNBS-8 026108 8 • 7.57 .060 • 1.5 .765 • 19.4 0.70 • 2.3 0.12 • 0.4 95 • 312 58 • 64 • 69 405 • 603

DPNBS-6 026109 6 • 12.5 .080 • 2.0 .920 • 23.4 0.46 • 1.5 0.11 • 0.4 126 • 413 83 • 85 • 91 580 • 863

DPNBS-5 026110 5 • 18.6 .080 • 2.0 1.040 • 26.4 0.33 • 1.1 0.11 • 0.4 140 • 459 95 • 101 • 108 720 • 1071

DPNBS-4 026111 4 • 21.5 .080 • 2.0 1.090 • 27.7 0.29 • 1.0 0.10 • 0.3 153 • 502 104 • 110 • 118 850 • 1265

DPNBS-3 026112 3 • 25.6 .080 • 2.0 1.140 • 29.0 0.23 • 0.8 0.10 • 0.3 173 • 567 121 • 132 • 141 940 • 1399

DPNBS-2 026113 2 • 30.7 .080 • 2.0 1.205 • 30.6 0.18 • 0.6 0.10 • 0.3 187 • 613 138 • 149 • 160 1045 • 1555

DPNBS-1 026114 1 • 46.0 .110 • 2.8 1.430 • 36.3 0.14 • 0.5 0.09 • 0.3 178 • 584 168 • 174 • 186 1480 • 2202

DPNBS-1/0 026115 1/0 • 56.3 .110 • 2.8 1.535 • 39.0 0.12 • 0.4 0.09 • 0.3 190 • 623 190 • 199 • 213 1695 • 2522

DPNBS-2/0 026116 2/0 • 66.5 .110 • 2.8 1.600 • 40.6 0.09 • 0.3 0.09 • 0.3 212 • 695 213 • 242 • 259 1845 • 2746

DPNBS-3/0 026117 3/0 • 92.1 .125 • 3.2 1.870 • 47.5 0.08 • 0.3 0.09 • 0.3 245 • 804 259 • 265 • 284 2585 • 3825

DPNBS-4/0 026118 4/0 • 112.6 .125 • 3.2 1.975 • 50.2 0.07 • 0.2 0.09 • 0.3 259 • 850 293 • 307 • 329 2980 • 4435

DPNBS-262 026119 262 • 133.0 .125 • 3.2 2.145 • 54.5 0.06 • 0.2 0.09 • 0.3 247 • 810 325 • 358 • 383 3445 • 5127

DPNBS-313 026120 313 • 158.6 .140 • 3.6 2.305 • 58.6 0.05 • 0.2 0.09 • 0.3 270 • 886 362 • 391 • 419 4005 • 5960

DPNBS-373 026121 373 • 189.3 .140 • 3.6 2.445 • 62.1 0.04 • 0.1 0.09 • 0.3 292 • 958 405 • 442 • 473 4650 • 6920

DPNBS-444 026122 444 • 225.1 .140 • 3.6 2.585 • 65.7 0.04 • 0.1 0.09 • 0.3 318 • 1043 451 • 504 • 540 5240 • 7798

DPNBS-535 026123 535 • 271.2 .155 • 3.9 2.865 • 72.8 0.04 • 0.1 0.09 • 0.3 291 • 954 507 • 538 • 576 6175 • 9189

DPNBS-646 026124 646 • 327.5 .155 • 3.9 3.065 • 77.9 0.04 • 0.1 0.09 • 0.3 314 • 1030 570 • 632 • 677 7185 • 10692

DPNBS-777 026125 777 • 393.8 .155 • 3.9 3.270 • 83.01 0.03 • 0.1 0.09 • 0.3 345 • 1132 641 • 684 • 733 8420 • 12530

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.†Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 - 1OOºC values based on IEEE-45 Table 25 - 11 O’C values based on IEEE-45Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

two conductor / armored and sheathed8 AWG to 777 MCM / 600V or 0.6/1kV

74

Page 82: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P POWER CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 29 of 62

Three conductor / unarmoredTYPE P POWER CABLE600V or 0.6/1kV8 AWG to 777 MCM

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored andsheathed version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Super-flexible at 4/0 AWG and larger• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

31 2

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

DUSA_MOG29_0807

75

Page 83: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 30 of 62

BOSTRIG™ TYPE P POWER CABLE

Jacket Cable Diameter Impedance Calculated Ampacity† Cable WeightType Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

TPN-8 026061 8 • 7.57 .060 • 1.5 .625 • 15.9 0.70 • 2.3 0.12 • 0.4 95 • 312 47 • 52 • 56 275 • 409

TPN-6 026062 6 • 12.5 .060 • 1.5 .750 • 19.1 0.46 • 1.5 0.11 • 0.4 126 • 413 63 • 70 • 75 420 • 625

TPN-5 026063 5 • 18.6 .080 • 2.0 .890 • 22.6 0.33 • 1.1 0.11 • 0.4 140 • 459 78 • 82 • 88 555 • 826

TPN-4 026064 4 • 21.5 .080 • 2.0 .925 • 23.5 0.29 • 1.0 0.10 • 0.3 153 • 502 86 • 92 • 99 695 • 1034

TPN-3 026065 3 • 25.6 .080 • 2.0 .975 • 24.8 0.23 • 0.8 0.10 • 0.3 173 • 567 99 • 108 • 116 805 • 1198

TPN-2 026066 2 • 30.7 .080 • 2.0 1.045 • 26.5 0.18 • 0.6 0.10 • 0.3 187 • 613 111 • 122 • 131 915 • 1362

TPN-1 026067 1 • 46.1 .080 • 2.0 1.225 • 31.1 0.14 • 0.5 0.09 • 0.3 178 • 584 137 • 143 • 153 1320 • 1964

TPN-1/0 026068 1/0 • 56.3 .080 • 2.0 1.340 • 34.0 0.12 • 0.4 0.09 • 0.3 190 • 623 156 • 164 • 176 1610 • 2395

TPN-2/0 026069 2/0 • 66.5 .110 • 2.8 1.440 • 36.6 0.09 • 0.3 0.09 • 0.3 212 • 695 175 • 188 • 201 1885 • 2805

TPN-3/0 026070 3/0 • 92.1 .110 • 2.8 1.665 • 42.3 0.08 • 0.3 0.09 • 0.3 245 • 804 213 • 218 • 234 2560 • 3810

TPN-4/0 026071 4/0 • 112.6 .125 • 3.2 1.800 • 45.7 0.07 • 0.2 0.09 • 0.3 259 • 850 241 • 252 • 270 3060 • 4555

TPN-262 026072 262 • 133.0 .125 • 3.2 1.950 • 49.5 0.06 • 0.2 0.09 • 0.3 247 • 810 267 • 294 • 315 3555 • 5290

TPN-313 026073 313 • 158.6 .125 • 3.2 2.095 • 53.2 0.05 • 0.2 0.09 • 0.3 270 • 886 298 • 321 • 344 4140 • 6161

TPN-373 026074 373 • 189.3 .125 • 3.2 2.245 • 57.0 0.04 • 0.1 0.09 • 0.3 292 • 958 333 • 361 • 387 4880 • 7262

TPN-444 026075 444 • 225.1 .140 • 3.6 2.425 • 61.6 0.04 • 0.1 0.09 • 0.3 318 • 1043 371 • 411 • 440 5800 • 8631

TPN-535 026076 535 • 271.2 .140 • 3.6 2.660 • 67.6 0.04 • 0.1 0.09 • 0.3 291 • 954 417 • 443 • 475 6945 • 10335

TPN-646 026077 646 • 327.5 .140 • 3.6 2.905 • 73.8 0.04 • 0.1 0.09 • 0.3 314 • 1030 469 • 516 • 553 8185 • 12818

TPN-777 026078 777 • 393.8 .140 • 3.6 3.095 • 78.6 0.03 • 0.1 0.09 • 0.3 345 • 1132 528 • 562 •602 9695 • 14428

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.†Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 - 1OOºC values based on IEEE-45 Table 25 - 11 O’C values based on IEEE-45Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

three conductor / unarmored8 AWG to 777 MCM / 600V or 0.6/1kV

DUSA_MOG30_0807

76

Page 84: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P POWER CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 5 of 62

Three conductor / armored and sheathedTYPE P POWER CABLE600V or 0.6/1kV8 AWG to 777 MCM

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.4. Armor Braided bronze in accordance with IEEE 1580 (2001).5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene

as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).They are suitable for use in Class I, Division I and Zone Iapplications (armored & sheathed) and meet the crushand impact resistance requirements (C&IR) of UL 2225.

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an unarmored version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Super-flexible at 4/0 AWG and larger• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998)for 600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

31 2 4 5

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

DUSA_MOG05_0807

77

Page 85: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 6 of 62

BOSTRIG™ TYPE P POWER CABLE

DUSA_MOG06_0807

Sheath Cable Diameter Impedance Calculated Ampacity† Cable WeightType Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

TPNBS-8 026126 8 • 7.57 .060 • 1.5 .835 • 21.2 0.70 • 2.3 0.12 • 0.4 95 • 312 47 • 52 • 56 480 • 714

TPNBS-6 026127 6 • 12.5 .080 • 2.0 .965 • 24.5 0.46 • 1.5 0.11 • 0.4 126 • 413 63 • 70 • 75 700 • 1042

TPNBS-5 026128 5 • 18.6 .080 • 2.0 1.120 • 28.5 0.33 • 1.1 0.11 • 0.4 140 • 459 78 • 82 • 88 900 • 1339

TPNBS-4 026129 4 • 21.5 .080 • 2.0 1.140 • 29.0 0.29 • 1.0 0.10 • 0.3 153 • 502 86 • 92 • 99 1040 • 1548

TPNBS-3 026130 3 • 25.6 .080 • 2.0 1.200 • 30.5 0.23 • 0.8 0.10 • 0.3 173 • 567 99 • 108 • 116 1160 • 1726

TPNBS-2 026131 2 • 30.7 .080 • 2.0 1.265 • 32.1 0.18 • 0.6 0.10 • 0.3 187 • 613 111 • 122 • 131 1295 • 1927

TPNBS-1 026132 1 • 46.1 .110 • 2.8 1.505 • 38.2 0.14 • 0.5 0.09 • 0.3 178 • 584 137 • 143 • 153 1850 • 2753

TPNBS-1/0 026133 1/0 • 56.3 .110 • 2.8 1.620 • 41.2 0.12 • 0.4 0.09 • 0.3 190 • 623 156 • 164 • 176 2190 • 3259

TPNBS-2/0 026134 2/0 • 66.5 .110 • 2.8 1.730 • 43.9 0.09 • 0.3 0.09 • 0.3 212 • 695 175 • 188 • 201 2500 • 3720

TPNBS-3/0 026135 3/0 • 92.1 .125 • 3.2 1.975 • 50.2 0.08 • 0.3 0.09 • 0.3 245 • 804 213 • 218 • 234 3330 • 4955

TPNBS-4/0 026136 4/0 • 112.6 .125 • 3.2 2.110 • 53.6 0.07 • 0.2 0.09 • 0.3 259 • 850 241 • 252 • 270 3890 • 5789

TPNBS-262 026137 262 • 133.0 .125 • 3.2 2.290 • 58.2 0.06 • 0.2 0.09 • 0.3 247 • 810 267 • 294 • 315 4515 • 6704

TPNBS-313 026138 313 • 158.6 .140 • 3.6 2.435 • 61.9 0.05 • 0.2 0.09 • 0.3 270 • 886 298 • 321 • 344 5170 • 7694

TPNBS-373 026139 373 • 189.3 .140 • 3.6 2.585 • 65.7 0.04 • 0.1 0.09 • 0.3 292 • 958 333 • 361 • 387 5975 • 8892

TPNBS-444 026140 444 • 225.1 .140 • 3.6 2.765 • 70.2 0.04 • 0.1 0.09 • 0.3 318 • 1043 371 • 411 • 440 6980 • 10387

TPNBS-535 026141 535 • 271.2 .140 • 3.6 3.030 • 77.0 0.04 • 0.1 0.09 • 0.3 291 • 954 417 • 443 • 475 8235 • 12255

TPNBS-646 026142 646 • 327.5 .140 • 3.6 3.275 • 83.2 0.04 • 0.1 0.09 • 0.3 314 • 1030 469 • 516 • 553 9575 • 14249

TPNBS-777 026143 777 • 393.8 .140 • 3.6 3.465 • 88.0 0.03 • 0.1 0.09 • 0.3 345 • 1132 528 • 562 •602 11280 • 16786

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.†Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 - 1OOºC values based on IEEE-45 Table 25 - 11 O’C values based on IEEE-45Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

three conductor / armored and sheathed8 AWG to 777 MCM / 600V or 0.6/1kV

78

Page 86: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P POWER CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 31 of 62

Four conductor / unarmoredTYPE P POWER CABLE600V or 0.6/1kV8 AWG to 777 MCM

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored andsheathed version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Super-flexible at 4/0 AWG and larger• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

31 2

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

DUSA_MOG31_0807

79

Page 87: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 32 of 62

BOSTRIG™ TYPE P POWER CABLE

four conductor / unarmored8 AWG to 777 MCM / 600V or 0.6/1kV

Jacket Cable Diameter Impedance Calculated Ampacity† Cable WeightType Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

FPN-8 026079 8 • 7.57 .060 • 1.5 .690 • 17.5 0.70 • 2.3 0.12 • 0.4 95 • 312 47 • 52 • 56 350 • 521

FPN-6 026080 6 • 12.5 .060 • 1.5 .820 • 20.8 0.46 • 1.5 0.11 • 0.4 126 • 413 63 • 70 • 75 540 • 804

FPN-5 026081 5 • 18.6 .080 • 2.0 .980 • 24.9 0.33 • 1.1 0.11 • 0.4 140 • 459 78 • 82 • 88 775 • 1153

FPN-4 026082 4 • 21.5 .080 • 2.0 1.020 • 25.9 0.29 • 1.0 0.10 • 0.3 153 • 502 86 • 92 • 99 885 • 1317

FPN-3 026083 3 • 25.6 .080 • 2.0 1.080 • 27.4 0.23 • 0.8 0.10 • 0.3 173 • 567 99 • 108 • 116 1025 • 1525

FPN-2 026084 2 • 30.7 .080 • 2.0 1.160 • 29.5 0.18 • 0.6 0.10 • 0.3 187 • 613 111 • 122 • 131 1170 • 1741

FPN-1 026085 1 • 46.1 .080 • 2.0 1.360 • 34.5 0.14 • 0.5 0.09 • 0.3 178 • 584 137 • 143 • 153 1710 • 2545

FPN-1/0 026086 1/0 • 56.3 .110 • 2.8 1.510 • 38.4 0.12 • 0.4 0.09 • 0.3 190 • 623 156 • 164 • 176 2100 • 3125

FPN-2/0 026087 2/0 • 66.5 .110 • 2.8 1.590 • 40.4 0.09 • 0.3 0.09 • 0.3 212 • 695 175 • 188 • 201 2410 • 3586

FPN-3/0 026088 3/0 • 92.1 .125 • 3.2 1.875 • 47.6 0.08 • 0.3 0.09 • 0.3 245 • 804 213 • 218 • 234 3360 • 5000

FPN-4/0 026089 4/0 • 112.6 .125 • 3.2 1.995 • 50.7 0.07 • 0.2 0.09 • 0.3 259 • 850 241 • 252 • 270 3940 • 5863

FPN-262 026090 262 • 133.0 .125 • 3.2 2.165 • 55.0 0.06 • 0.2 0.09 • 0.3 247 • 810 267 • 294 • 315 4640 • 6905

FPN-313 026091 313 • 158.6 .140 • 3.6 2.355 • 59.8 0.05 • 0.2 0.09 • 0.3 270 • 886 298 • 321 • 344 5475 • 8148

FPN-373 026092 373 • 189.3 .140 • 3.6 2.525 • 64.1 0.04 • 0.1 0.09 • 0.3 292 • 958 333 • 361 • 387 6365 • 9472

FPN-444 026093 444 • 225.1 .140 • 3.6 2.695 • 68.5 0.04 • 0.1 0.09 • 0.3 318 • 1043 371 • 411 • 440 7500 • 11161

FPN-535 026094 535 • 271.2 .140 • 3.6 2.990 • 76.0 0.04 • 0.1 0.09 • 0.3 291 • 954 417 • 443 • 475 8970 • 13349

FPN-646 026095 646 • 327.5 .140 • 3.6 3.230 • 82.0 0.04 • 0.1 0.09 • 0.3 314 • 1030 469 • 516 • 553 10640 • 15834

FPN-777 026096 777 • 393.8 .140 • 3.6 3.445 • 87.5 0.03 • 0.1 0.09 • 0.3 345 • 1132 528 • 562 • 602 12730 • 18944

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.†Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 - 1OOºC values based on IEEE-45 Table 25 - 11 O’C values based on IEEE-45Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by0.66; 4/0 AWG thru 1000 MCM multiply by O.64.The ampacity of 4 conductor cables is based on three current carrying conductors and the fourth conductor being used as a Neutral or Grounding conductor. If all conductors are current carrying, the ampacity must be reduced by 0.8.

DUSA_MOG32_0807

80

Page 88: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P POWER CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 7 of 62

Four conductor / armored and sheathedTYPE P POWER CABLE600V or 0.6/1kV8 AWG to 777 MCM

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.4. Armor Braided bronze in accordance with IEEE 1580 (2001).5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene

as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).They are suitable for use in Class I, Division I and Zone Iapplications (armored & sheathed) and meet the crushand impact resistance requirements (C&IR) of UL 2225.

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an unarmored version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Super-flexible at 4/0 AWG and larger• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables complywith the Crush and Impact requirements ofUL 2225.

31 2 4 5

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

DUSA_MOG07_0807

81

Page 89: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 8 of 62

BOSTRIG™ TYPE P POWER CABLE

DUSA_MOG08_0807

four conductor / armored and sheathed8 AWG to 777 MCM / 600V or 0.6/1kV

Sheath Cable Diameter Impedance Calculated Ampacity† Cable WeightType Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

FPNBS-8 026144 8 • 7.57 .060 • 1.5 .910 • 23.1 0.70 • 2.3 0.13 • 0.4 95 • 312 47 • 52 • 56 605 • 900

FPNBS-6 026145 6 • 12.5 .080 • 2.0 1.045 • 26.5 0.46 • 1.5 0.12 • 0.4 126 • 413 63 • 70 • 75 890 • 1324

FPNBS-5 026146 5 • 18.6 .080 • 2.0 1.210 • 30.7 0.33 • 1.1 0.11 • 0.4 140 • 459 78 • 82 • 88 1140 • 1696

FPNBS-4 026147 4 • 21.5 .080 • 2.0 1.240 • 31.5 0.29 • 1.0 0.11 • 0.4 153 • 502 86 • 92 • 99 1265 • 1883

FPNBS-3 026148 3 • 25.6 .080 • 2.0 1.300 • 33.0 0.23 • 0.8 0.11 • 0.4 173 • 567 99 • 108 • 116 1415 • 2106

FPNBS-2 026149 2 • 30.7 .080 • 2.0 1.440 • 36.6 0.18 • 0.6 0.10 • 0.3 187 • 613 111 • 122 • 131 1675 • 2493

FPNBS-1 026150 1 • 46.1 .110 • 2.8 1.640 • 41.7 0.14 • 0.5 0.10 • 0.3 178 • 584 137 • 143 • 153 2300 • 3423

FPNBS-1/0 026151 1/0 • 56.3 .110 • 2.8 1.820 • 46.2 0.12 • 0.4 0.10 • 0.3 190 • 623 156 • 164 • 176 2860 • 4256

FPNBS-2/0 026152 2/0 • 66.5 .110 • 2.8 1.920 • 48.8 0.09 • 0.3 0.10 • 0.3 212 • 695 175 • 188 • 201 3150 • 4688

FPNBS-3/0 026153 3/0 • 92.1 .125 • 3.2 2.185 • 55.5 0.08 • 0.3 0.10 • 0.3 245 • 804 213 • 218 • 234 4220 • 6280

FPNBS-4/0 026154 4/0 • 112.6 .125 • 3.2 2.335 • 59.3 0.07 • 0.2 0.09 • 0.3 259 • 850 241 • 252 • 270 4920 • 7322

FPNBS-262 026155 262 • 133.0 .125 • 3.2 2.505 • 63.6 0.06 • 0.2 0.09 • 0.3 247 • 810 267 • 294 • 315 5700 • 8483

FPNBS-313 026156 313 • 158.6 .140 • 3.6 2.695 • 68.5 0.05 • 0.2 0.09 • 0.3 270 • 886 298 • 321 • 344 6620 • 9852

FPNBS-373 026157 373 • 189.3 .140 • 3.6 2.895 • 73.5 0.04 • 0.1 0.09 • 0.3 292 • 958 333 • 361 • 387 7590 • 11295

FPNBS-444 026158 444 • 225.1 .140 • 3.6 3.065 • 77.9 0.04 • 0.1 0.09 • 0.3 318 • 1043 371 • 411 • 440 8800 • 13096

FPNBS-535 026159 535 • 271.2 .140 • 3.6 3.360 • 85.3 0.04 • 0.1 0.09 • 0.3 291 • 954 417 • 443 • 475 10500 • 15626

FPNBS-646 026160 646 • 327.5 .140 • 3.6 3.600 • 91.4 0.04 • 0.1 0.09 • 0.3 314 • 1030 469 • 516 • 553 12290 • 18290

FPNBS-777 026161 777 • 393.8 .140 • 3.6 3.815 • 96.9 0.04 • 0.1 0.09 • 0.3 345 • 1132 528 • 562 • 602 14500 • 21578

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.†Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 - 1OOºC values based on IEEE-45 Table 25 - 11 O’C values based on IEEE-45Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by0.66; 4/0 AWG thru 1000 MCM multiply by O.64.The ampacity of 4 conductor cables is based on three current carrying conductors and the fourth conductor being used as a Neutral or Grounding conductor. If all conductors are current carrying, the ampacity must be reduced by 0.8.

82

Page 90: Prysmian Draka - Marine & Offshore LV HV Cables

Five conductor / armored and sheathedTYPE P POWER CABLE600V or 0.6/1kV8 to 4/0 AWG

www.DrakaMOG.com

BOSTRIG™ TYPE P POWER CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 33 of 62

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored andsheathed version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Super-flexible at 4/0 AWG and larger• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

31 2

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

DUSA_MOG33_0807

83

Page 91: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 34 of 62

BOSTRIG™ TYPE P POWER CABLE

Jacket Cable Diameter Impedance Calculated Ampacity† Cable WeightType Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

QPN-8 026097 8 • 7.57 .060 • 1.5 760 • 19.3 0.70 • 2.3 0.12 • 0.4 95 • 312 38 • 42 • 45 430 • 640

QPN-6 026098 6 • 12.5 .080 • 2.0 .955 • 24.3 0.46 • 1.5 0.11 • 0.4 126 • 413 50 • 56 • 60 700 • 1042

QPN-5 026099 5 • 18.6 .080 • 2.0 1.080 • 27.4 0.33 • 1.1 0.11 • 0.4 140 • 459 62 • 66 • 70 950 • 1414

QPN-4 026100 4 • 21.5 .080 • 2.0 1.125 • 28.6 0.29 • 1.0 0.10 • 0.3 153 • 502 69 • 74 • 79 1100 • 1637

QPN-3 026101 3 • 25.6 .110 • 2.8 1.195 • 30.4 0.23 • 0.8 0.10 • 0.3 173 • 567 79 • 86 • 93 1260 • 1875

QPN-2 026102 2 • 30.7 .110 • 2.8 1.280 • 32.5 0.18 • 0.6 0.10 • 0.3 187 • 613 89 • 98 • 105 1450 • 2158

QPN-1 026103 1 • 46.1 .125 • 3.2 1.565 • 39.8 0.14 • 0.5 0.09 • 0.3 178 • 584 110 • 114 • 122 2205 • 3282

QPN-1/0 026104 1/0 • 56.3 .125 • 3.2 1.715 • 43.6 0.12 • 0.4 0.09 • 0.3 190 • 623 125 • 131 • 141 2650 • 3945

QPN-2/0 026105 2/0 • 66.5 .125 • 3.2 1.790 • 45.5 0.09 • 0.3 0.09 • 0.3 212 • 695 140 • 150 • 161 3015 • 4487

QPN-3/0 026106 3/0 • 92.1 .140 • 3.6 2.075 • 52.7 0.08 • 0.3 0.09 • 0.3 245 • 804 170 • 174 • 187 4140 • 6161

QPN-4/0 026107 4/0 • 112.6 .140 • 3.6 2.210 • 56.1 0.07 • 0.2 0.09 • 0.3 259 • 850 193 • 202 • 216 4850 • 7218

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.†Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 - 1OOºC values based on IEEE-45 Table 25 - 11 O’C values based on IEEE-45Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

five conductor / unarmored8 to 4/0 AWG / 600V or 0.6/1kV

DUSA_MOG34_0807

84

Page 92: Prysmian Draka - Marine & Offshore LV HV Cables

Five conductor / armored and sheathedTYPE P POWER CABLE600V or 0.6/1kV8 to 4/0 AWG

www.DrakaMOG.com

BOSTRIG™ TYPE P POWER CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 9 of 62

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.4. Armor Braided bronze in accordance with IEEE 1580 (2001).5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene

as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).They are suitable for use in Class I, Division I and Zone Iapplications (armored & sheathed) and meet the crushand impact resistance requirements (C&IR) of UL 2225.

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an unarmored version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Super-flexible at 4/0 AWG and larger• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

31 2 4 5

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J105

DUSA_MOG09_0807

85

Page 93: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 10 of 62

BOSTRIG™ TYPE P POWER CABLE

DUSA_MOG10_0807

Sheath Cable Diameter Impedance Calculated Ampacity† Cable WeightType Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

QPNBS-8 026162 8 • 7.57 .080 • 2.0 .980 • 24.9 0.70 • 2.3 0.13 • 0.4 95 • 312 38 • 42 • 45 710 • 1057

QPNBS-6 026163 6 • 12.5 .080 • 2.0 1.175 • 29.9 0.46 • 1.5 0.12 • 0.4 126 • 413 50 • 56 • 60 1045 • 1555

QPNBS-5 026164 5 • 18.6 .080 • 2.0 1.310 • 33.2 0.33 • 1.1 0.11 • 0.4 140 • 459 62 • 66 • 70 1350 • 2009

QPNBS-4 026165 4 • 21.5 .080 • 2.0 1.345 • 34.2 0.29 • 1.0 0.11 • 0.4 153 • 502 69 • 74 • 79 1510 • 2247

QPNBS-3 026166 3 • 25.6 .110 • 2.8 1.475 • 37.5 0.23 • 0.8 0.11 • 0.4 173 • 567 79 • 86 • 93 1775 • 2642

QPNBS-2 026167 2 • 30.7 .110 • 2.8 1.560 • 39.6 0.18 • 0.6 0.10 • 0.3 187 • 613 89 • 98 • 105 2000 • 2976

QPNBS-1 026168 1 • 46.1 .125 • 3.2 1.875 • 47.6 0.14 • 0.5 0.10 • 0.3 178 • 584 110 • 114 • 122 2930 • 4360

QPNBS-1/0 026169 1/0 • 56.3 .125 • 3.2 2.025 • 51.4 0.12 • 0.4 0.10 • 0.3 190 • 623 125 • 131 • 141 3435 • 5112

QPNBS-2/0 026170 2/0 • 66.5 .125 • 3.2 2.120 • 53.9 0.09 • 0.3 0.10 • 0.3 212 • 695 140 • 150 • 161 3830 • 5700

QPNBS-3/0 026171 3/0 • 92.1 .140 • 3.6 2.415 • 61.3 0.08 • 0.3 0.10 • 0.3 245 • 804 170 • 174 • 187 5150 • 7664

QPNBS-4/0 026172 4/0 • 112.6 .140 • 3.6 2.550 • 64.8 0.07 • 0.2 0.09 • 0.3 259 • 850 193 • 202 • 216 5930 • 8825

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.†Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 - 1OOºC values based on IEEE-45 Table 25 - 11 O’C values based on IEEE-45Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

five conductor / armored and sheathed8 to 4/0 AWG / 600V or 0.6/1kV

86

Page 94: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG51_0807

BOSTRIG™ TYPE P SIGNAL CABLE 600V

Bostrig Type P0807

Page 51 of 62

Overall shielded multiconductor /armored and sheathedTYPE P SIGNAL CABLE600V20, 18 & 16 AWG

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No.95/00161 (E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured tc BIW Specifying Standard J106

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an unarmored version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight,mud, crush and impact

• Super-flexible at 4/0 AWG and larger• Meets IEEE standards for 600V / IEC standards for

0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and theflame test in IEC 60332-3, Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245and IEEE 45 (1998) for 600V.

31 2 4 5 6

www.DrakaMOG.comSubject to change without prior notice

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over the cabled core.4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580

(2001). Thickness as shown on data sheet for unarmored version.5 Armor Braided bronze in accordance with IEEE 1580 (2001).6. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene

as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

87

Page 95: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG52_0807

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 52 of 62

BOSTRIG™ TYPE P SIGNAL CABLE

overall shielded multiconductor / armored and sheathed20, 18 & 16 AWG / 600V20 AWG • 0.61 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Stranding Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km

C(0S)20PNBS-3 026503 3 19/32 .030 • 0.76 .060 • 1.5 .533 • 13.5 185 • 275

C(0S)20PNBS-4 026504 4 19/32 .030 • 0.76 .060 • 1.5 .557 • 14.2 210 • 313

C(0S)20PNBS-5 026505 5 19/32 .030 • 0.76 .060 • 1.5 .586 • 14.8 230 • 342

C(0S)20PNBS-6 026506 6 19/32 .030 • 0.76 .060 • 1.5 .614 • 15.6 255 • 380

18 AWG • 0.96 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Stranding Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km

C(0S)18PNBS-3 026507 3 19/30 .030 • 0.76 .060 • 1.5 .540 • 13.7 205 • 305

C(0S)18PNBS-4 026508 4 19/30 .030 • 0.76 .060 • 1.5 .569 • 14.5 231 • 344

C(0S)18PNBS-5 026509 5 19/30 .030 • 0.76 .060 • 1.5 .613 • 15.6 259 • 389

C(0S)18PNBS-6 026510 6 19/30 .030 • 0.76 .060 • 1.5 .345 • 16.4 286 • 426

C(0S)18PNBS-25 25 19/30 .030 • 0.76 .060 • 1.5 1.074 • 27.3 705 • 1049

16 AWG • 1.23 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Stranding Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km

C(0S)16PNBS-3 026511 3 19/29 .030 • 0.76 .060 • 1.5 .564 • 14.3 221 • 329

C(0S)16PNBS-4 026512 4 19/29 .030 • 0.76 .060 • 1.5 .584 • 14.8 242 • 360

C(0S)16PNBS-5 026513 5 19/29 .030 • 0.76 .060 • 1.5 .633 • 16.1 283 • 421

C(0S)16PNBS-6 026514 6 19/29 .030 • 0.76 .060 • 1.5 .666 • 16.9 313 • 466

C(0S)16PNBS-12 12 19/29 .030 • 0.76 .060 • 1.5 .820 • 20.8 470 • 699

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

88

Page 96: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG49_0807

BOSTRIG™ TYPE P SIGNAL CABLE 600V

Bostrig Type P0807

Page 49 of 62

Overall shielded multiconductor / unarmoredTYPE P SIGNAL CABLE600V20, 18 & 16 AWG

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No.95/00161 (E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured tc BIW Specifying Standard J106

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight,mud, crush and impact

• Super-flexible at 4/0 AWG and larger• Meets IEEE standards for 600V / IEC standards for

0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and theflame test in IEC 60332-3, Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245and IEEE 45 (1998) for 600V & 2000V.

31 2 4

www.DrakaMOG.comSubject to change without prior notice

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair

and the cabled core. The single pair construction has only the overall shield.4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580

(2001). Thickness as shown in tables on opposite page.

89

Page 97: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 50 of 62

BOSTRIG™ TYPE P SIGNAL CABLE

overall shielded multiconductor / unarmored20, 18 & 16 AWG / 600V20 AWG • 0.61 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Stranding Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km

C(0S)20PN-3 026491 3 19/32 .030 • 0.76 .060 • 1.5 .345 • 8.8 65 • 97

C(0S)20PN-4 026492 4 19/32 .030 • 0.76 .060 • 1.5 .373 • 9.5 81 • 121

C(0S)20PN-5 026493 5 19/32 .030 • 0.76 .060 • 1.5 .403 • 10.2 92 • 137

C(0S)20PN-6 026494 6 19/32 .030 • 0.76 .060 • 1.5 .431 • 10.9 107 • 159

18 AWG • 0.96 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Stranding Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km

C(0S)18PN-3 3 19/30 .030 • 0.76 .060 • 1.5 .358 • 9.1 78 • 116

C(0S)18PN-4 026496 4 19/30 .030 • 0.76 .060 • 1.5 .385 • 9.8 92 • 137

C(0S)18PN-5 026497 5 19/30 .030 • 0.76 .060 • 1.5 .435 • 11.0 113 • 168

C(0S)18PN-6 026498 6 19/30 .030 • 0.76 .060 • 1.5 .467 • 11.9 130 • 193

C(0S)18PN-25 25 19/30 .030 • 0.76 .060 • 1.5 .795 • 20.2 395 • 588

16 AWG • 1.23 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Stranding Thickness Thickness (nominal) (approximate)Designation Number Conductors in • mm in • mm in • mm Lbs/mft • Kg/km

C(0S)16PN-3 030645 3 19/29 .030 • 0.76 .060 • 1.5 .386 • 9.8 88 • 131

C(0S)16PN-4 026500 4 19/29 .030 • 0.76 .060 • 1.5 .400 • 10.2 104 • 155

C(0S)16PN-5 026501 5 19/29 .030 • 0.76 .060 • 1.5 .455 • 11.6 130 • 193

C(0S)16PN-6 026502 6 19/29 .030 • 0.76 .060 • 1.5 .488 • 12.4 150 • 223

C(0S)16PN-12 027052 12 19/29 .030 • 0.76 .060 • 1.5 .625 • 15.9 260 • 387

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

DUSA_MOG50_0807

90

Page 98: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG45_0807

BOSTRIG™ TYPE P SIGNAL CABLE 600V OR 0.6/1kV

Bostrig Type P0807

Page 45 of 62

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair

and the cabled core. The single pair construction has only the overall shield.4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580

(2001). Thickness as shown in tables on opposite page.

Individual and overall shielded multipair /unarmoredTYPE P SIGNAL CABLE600V or 0.6/1kV16 & 14 AWG

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No.95/00161 (E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured tc BIW Specifying Standard J106

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored andsheathed version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC60332-3, Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

31 2 4

www.DrakaMOG.comSubject to change without prior notice

91

Page 99: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG46_0807

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 46 of 62

BOSTRIG™ TYPE P SIGNAL CABLE

individual and overall shielded multipair / unarmored and sheathed16 & 14 AWG / 600V or 0.6/1kV

16 AWG • 1.23 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Pairs in • mm in • mm in • mm Lbs/mft • Kg/km

TP(0S)16PN-1 026364 1 .030 • 0.76 .060 • 1.5 .350 • 8.9 65 • 97

TP(I/S-0S)16PN-2 026365 2 .030 • 0.76 .060 • 1.5 .620 • 15.6 170 • 253

TP(I/S-0S)16PN-3 026366 3 .030 • 0.76 .060 • 1.5 .665 • 16.9 215 • 320

TP(I/S-0S)16PN-4 026367 4 .030 • 0.76 .060 • 1.5 .695 • 17.7 240 • 357

TP(I/S-0S)16PN-5 026368 5 .030 • 0.76 .060 • 1.5 .740 • 18.8 275 • 409

TP(I/S-0S)16PN-6 026369 6 .030 • 0.76 .060 • 1.5 .805 • 20.1 320 • 476

TP(I/S-0S)16PN-7 026370 7 .030 • 0.76 .060 • 1.5 .805 • 20.1 345 • 513

TP(I/S-0S)16PN-8 026371 8 .030 • 0.76 .080 • 2.0 .985 • 25.0 475 • 707

TP(I/S-0S)16PN-10 026372 10 .030 • 0.76 .080 • 2.0 1.010 • 25.7 510 • 759

TP(I/S-0S)16PN-12 026373 12 .030 • 0.76 .080 • 2.0 1.065 • 27.1 585 • 871

TP(I/S-0S)16PN-16 026374 16 .030 • 0.76 .080 • 2.0 1.185 • 30.1 750 • 1116

TP(I/S-0S)16PN-20 026375 20 .030 • 0.76 .080 • 2.0 1.305 • 33.2 915 • 1362

TP(I/S-0S)16PN-24 026376 24 .030 • 0.76 .110 • 2.8 1.520 • 38.6 1165 • 1734

14 AWG • 1.94 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Pairs in • mm in • mm in • mm Lbs/mft • Kg/km

TP(0S)14PN-1 026377 1 .030 • 0.76 .060 • 1.5 .395 • 10.0 85 • 126

TP(I/S-0S)14PN-2 026378 2 .030 • 0.76 .060 • 1.5 .640 • 16.3 180 • 268

TP(I/S-0S)14PN-3 026379 3 .030 • 0.76 .060 • 1.5 .680 • 17.3 235 • 350

TP(I/S-0S)14PN-4 026380 4 .030 • 0.76 .060 • 1.5 .650 • 19.1 290 • 432

TP(I/S-0S)14PN-5 026381 5 .030 • 0.76 .060 • 1.5 .810 • 20.6 345 • 513

TP(I/S-0S)14PN-6 026382 6 .030 • 0.76 .080 • 2.0 .920 • 23.4 450 • 670

TP(I/S-0S)14PN-7 026383 7 .030 • 0.76 .080 • 2.0 .920 • 23.4 475 • 707

TP(I/S-0S)14PN-8 026384 8 .030 • 0.76 .080 • 2.0 .995 • 25.3 540 • 804

TP(I/S-0S)14PN-10 026385 10 .030 • 0.76 .080 • 2.0 1.070 • 27.2 635 • 945

TP(I/S-0S)14PN-12 026386 12 .030 • 0.76 .080 • 2.0 1.165 • 29.6 760 • 1131

TP(I/S-0S)14PN-16 026387 16 .030 • 0.76 .080 • 2.0 1.300 • 33.0 975 • 1451

TP(I/S-0S)14PN-20 026388 20 .030 • 0.76 .110 • 2.8 1.490 • 37.9 1280 • 1905

TP(I/S-0S)14PN-24 026389 24 .030 • 0.76 .110 • 2.8 1.670 • 42.4 1515 • 2255

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

92

Page 100: Prysmian Draka - Marine & Offshore LV HV Cables

BOSTRIG™ TYPE P SIGNAL CABLE 600V OR 0.6/1kV

Bostrig Type P0807

Page 21 of 62

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair

and the cabled core. The single pair construction has only the overall shield.4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580

(2001). Thickness as shown on data sheet for unarmored version.5 Armor Braided bronze in accordance with IEEE 1580 (2001).6. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene

as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Individual and overall shielded multipair /armored and sheathedTYPE P SIGNAL CABLE600V or 0.6/1kV16 & 14 AWG

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J106

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).They are suitable for use in Class I, Division I and Zone Iapplications (armored & sheathed) and meet the crushand impact resistance requirements (C&IR) of UL 2225.

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an unarmored version.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC60332-3, Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

31 2 54 6

www.DrakaMOG.comSubject to change without prior notice DUSA_MOG21_0807

93

Page 101: Prysmian Draka - Marine & Offshore LV HV Cables

16 AWG • 1.23 mm2

Insulation Sheath Cable Diameter Characteristic Cable WeightType Draka Number of Thickness Thickness (nominal) Impedance Inductance Capacitance (approximate)Designation Number Pairs in • mm in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m Lbs/mft • Kg/km

TP(0S)16PNBS-1 026429 1 .030 • 0.76 .060 • 1.5 .535 • 13.6 68 • 223 0.12 • 39 25 • 82 190 • 283

TP(I/S-0S)16PNBS-2 026430 2 .030 • 0.76 .060 • 1.5 .805 • 20.5 68 • 223 0.12 • 39 25 • 82 350 • 521

TP(I/S-0S)16PNBS-3 026431 3 .030 • 0.76 .080 • 2.0 .885 • 22.5 68 • 223 0.12 • 39 25 • 82 425 • 632

TP(I/S-0S)16PNBS-4 026432 4 .030 • 0.76 .080 • 2.0 .920 • 23.4 68 • 223 0.12 • 39 25 • 82 490 • 729

TP(I/S-0S)16PNBS-5 026433 5 .030 • 0.76 .080 • 2.0 .965 • 24.5 68 • 223 0.12 • 39 25 • 82 545 • 811

TP(I/S-0S)16PNBS-6 026434 6 .030 • 0.76 .080 • 2.0 1.025 • 26.0 68 • 223 0.12 • 39 25 • 82 610 • 908

TP(I/S-0S)16PNBS-7 026435 7 .030 • 0.76 .080 • 2.0 1.025 • 26.0 68 • 223 0.12 • 39 25 • 82 635 • 945

TP(I/S-0S)16PNBS-8 026436 8 .030 • 0.76 .080 • 2.0 1.205 • 30.6 68 • 223 0.12 • 39 25 • 82 800 • 1191

TP(I/S-0S)16PNBS-10 026437 10 .030 • 0.76 .080 • 2.0 1.235 • 31.4 68 • 223 0.12 • 39 25 • 82 875 • 1302

TP(I/S-0S)16PNBS-12 026438 12 .030 • 0.76 .080 • 2.0 1.285 • 32.6 68 • 223 0.12 • 39 25 • 82 965 • 1436

TP(I/S-0S)16PNBS-16 026439 16 .030 • 0.76 .110 • 2.8 1.465 • 37.2 68 • 223 0.12 • 39 25 • 82 1255 • 1868

TP(I/S-0S)16PNBS-20 026440 20 .030 • 0.76 .110 • 2.8 1.585 • 40.2 68 • 223 0.12 • 39 25 • 82 1470 • 2188

TP(I/S-0S)16PNBS-24 026441 24 .030 • 0.76 .125 • 3.2 1.835 • 46.6 68 • 223 0.12 • 39 25 • 82 1860 • 2786

14 AWG • 1.94 mm2

Insulation Sheath Cable Diameter Characteristic Cable WeightType Draka Number of Thickness Thickness (nominal) Impedance Inductance Capacitance (approximate)Designation Number Pairs in • mm in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m Lbs/mft • Kg/km

TP(0S)14PNBS-1 026693 1 .030 • 0.76 .060 • 1.5 .575 • 14.6 60 • 197 0.10 • 33 28 • 92 220 • 327

TP(I/S-0S)14PNBS-2 026443 2 .030 • 0.76 .060 • 1.5 .820 • 20.8 68 • 223 0.12 • 39 25 • 82 385 • 573

TP(I/S-0S)14PNBS-3 026444 3 .030 • 0.76 .080 • 2.0 .900 • 22.9 68 • 223 0.12 • 39 25 • 82 490 • 729

TP(I/S-0S)14PNBS-4 026445 4 .030 • 0.76 .080 • 2.0 .970 • 24.6 68 • 223 0.12 • 39 25 • 82 575 • 856

TP(I/S-0S)14PNBS-5 026446 5 .030 • 0.76 .080 • 2.0 1.030 • 26.2 68 • 223 0.12 • 39 25 • 82 650 • 967

TP(I/S-0S)14PNBS-6 026447 6 .030 • 0.76 .080 • 2.0 1.140 • 29.0 68 • 223 0.12 • 39 25 • 82 780 • 1161

TP(I/S-0S)14PNBS-7 026448 7 .030 • 0.76 .080 • 2.0 1.140 • 29.0 68 • 223 0.12 • 39 25 • 82 810 • 1205

TP(I/S-0S)14PNBS-8 026449 8 .030 • 0.76 .080 • 2.0 1.215 • 30.9 68 • 223 0.12 • 39 25 • 82 900 • 1339

TP(I/S-0S)14PNBS-10 026450 10 .030 • 0.76 .080 • 2.0 1.290 • 32.8 68 • 223 0.12 • 39 25 • 82 1030 • 1533

TP(I/S-0S)14PNBS-12 026451 12 .030 • 0.76 .110 • 2.8 1.445 • 36.7 68 • 223 0.12 • 39 25 • 82 1250 • 1860

TP(I/S-0S)14PNBS-16 026452 16 .030 • 0.76 .110 • 2.8 1.580 • 40.1 68 • 223 0.12 • 39 25 • 82 1525 • 2269

TP(I/S-0S)14PNBS-20 026453 20 .030 • 0.76 .125 • 3.2 1.800 • 45.7 68 • 223 0.12 • 39 25 • 82 1960 • 2917

TP(I/S-0S)14PNBS-24 026454 24 .030 • 0.76 .125 • 3.2 1.980 • 50.3 68 • 223 0.12 • 39 25 • 82 2260 • 3363

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 22 of 62

BOSTRIG™ TYPE P SIGNAL CABLE

individual and overall shielded multipair / armored and sheathed16 & 14 AWG / 600V or 0.6/1kV

DUSA_MOG22_0807

94

Page 102: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P CONTROL CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 43 of 62

Individual and overall shielded multipair /unarmoredTYPE P CONTROL CABLE600V or 0.6/1kV20 & 18 AWG

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored andsheathed version.

31 2 4

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No.95/00161 (E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured tc BIW Specifying Standard J105

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame testin IEC 60332-3, Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45(1998) for 600V.

Bostrig Type P cables comply with the Crush and Impact require-ments of UL 2225.

DUSA_MOG43_0807

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair

and the cabled core. The single pair construction has only the overall shield.4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580

(2001). Thickness as shown in tables on opposite page.

95

Page 103: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG44_0807

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 44 of 62

BOSTRIG™ TYPE P CONTROL CABLE

individual and overall shielded multipair / unarmored20 & 18 AWG / 600V or 0.6/1kV

20 AWG • 0.61 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Pairs in • mm in • mm in • mm Lbs/mft • Kg/km

TP(0S)20PN-1 026338 1 .030 • 0.76 .060 • 1.5 .330 • 8.4 55 • 92

TP(I/S-0S)20PN-2 026339 2 .030 • 0.76 .060 • 1.5 .540 • 13.7 120 • 179

TP(I/S-0S)20PN-3 026340 3 .030 • 0.76 .060 • 1.5 .550 • 13.9 135 • 201

TP(I/S-0S)20PN-4 026341 4 .030 • 0.76 .060 • 1.5 .600 • 15.2 165 • 246

TP(I/S-0S)20PN-5 026342 5 .030 • 0.76 .060 • 1.5 .650 • 16.5 190 • 283

TP(I/S-0S)20PN-6 026343 6 .030 • 0.76 .060 • 1.5 .700 • 17.8 215 • 320

TP(I/S-0S)20PN-7 026344 7 .030 • 0.76 .060 • 1.5 .700 • 17.8 230 • 342

TP(I/S-0S)20PN-8 026345 8 .030 • 0.76 .060 • 1.5 .760 • 19.3 265 • 394

TP(I/S-0S)20PN-10 026346 10 .030 • 0.76 .080 • 2.0 .900 • 22.9 360 • 536

TP(I/S-0S)20PN-12 026347 12 .030 • 0.76 .080 • 2.0 .925 • 23.5 400 • 595

TP(I/S-0S)20PN-16 026348 16 .030 • 0.76 .080 • 2.0 1.030 • 26.2 510 • 759

TP(I/S-0S)20PN-20 026349 20 .030 • 0.76 .080 • 2.0 1.130 • 28.7 600 • 893

TP(I/S-0S)20PN-24 026350 24 .030 • 0.76 .080 • 2.0 1.265 • 32.1 720 • 1071

18 AWG • 0.96 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Pairs in • mm in • mm in • mm Lbs/mft • Kg/km

TP(0S)18PN-1 1 .030 • 0.76 .060 • 1.5 .350 • 8.9 65 • 97

TP(I/S-0S)18PN-2 026352 2 .030 • 0.76 .060 • 1.5 .605 • 15.4 160 • 238

TP(I/S-0S)18PN-3 026353 3 .030 • 0.76 .060 • 1.5 .635 • 16.1 180 • 268

TP(I/S-0S)18PN-4 026354 4 .030 • 0.76 .060 • 1.5 .675 • 17.2 225 • 335

TP(I/S-0S)18PN-5 026355 5 .030 • 0.76 .060 • 1.5 .710 • 18.0 245 • 365

TP(I/S-0S)18PN-6 026356 6 .030 • 0.76 .060 • 1.5 .765 • 19.4 285 • 424

TP(I/S-0S)18PN-7 026357 7 .030 • 0.76 .060 • 1.5 .800 • 20.3 340 • 506

TP(I/S-0S)18PN-8 026358 8 .030 • 0.76 .080 • 2.0 .960 • 24.4 440 • 655

TP(I/S-0S)18PN-10 026359 10 .030 • 0.76 .080 • 2.0 1.025 • 26.0 515 • 766

TP(I/S-0S)18PN-12 026360 12 .030 • 0.76 .080 • 2.0 1.045 • 26.5 565 • 841

TP(I/S-0S)18PN-16 026361 16 .030 • 0.76 .080 • 2.0 1.160 • 29.5 720 • 1071

TP(I/S-0S)18PN-20 026362 20 .030 • 0.76 .080 • 2.0 1.240 • 31.5 825 • 1228

TP(I/S-0S)18PN-24 026363 24 .030 • 0.76 .110 • 2.8 1.450 • 36.8 1060 • 1577

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

96

Page 104: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P SIGNAL CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 19 of 62

Individual and overall shielded multipair /armored and sheathedTYPE P SIGNAL CABLE600V or 0.6/1kV20 & 18 AWG

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).They are suitable for use in Class I, Division I and Zone Iapplications (armored & sheathed) and meet the crushand impact resistance requirements (C&IR) of UL 2225.

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an unarmored version.

31 2 54 6

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J106

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair

and the cabled core. The single pair construction has only the overall shield.4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in

IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.5. Armor Braided bronze in accordance with IEEE 1580 (2001).6. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene

as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

DUSA_MOG19_0807

97

Page 105: Prysmian Draka - Marine & Offshore LV HV Cables

20 AWG • 0.61 mm2

Insulation Sheath Cable Diameter Characteristic Cable WeightType Draka Number of Thickness Thickness (nominal) Impedance Inductance Capacitance (approximate)Designation Number Pairs in • mm in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m Lbs/mft • Kg/km

TP(0S)20PNBS-1 026403 1 .030 • 0.76 .060 • 1.5 .510 • 13.0 82 • 269 0.14 • 46 21 • 69 170 • 253

TP(I/S-0S)20PNBS-2 026404 2 .030 • 0.76 .060 • 1.5 .720 • 18.3 82 • 269 0.14 • 46 21 • 69 295 • 439

TP(I/S-0S)20PNBS-3 026405 3 .030 • 0.76 .060 • 1.5 .730 • 18.5 82 • 269 0.14 • 46 21 • 69 320 • 476

TP(I/S-0S)20PNBS-4 026406 4 .030 • 0.76 .060 • 1.5 .780 • 19.8 82 • 269 0.14 • 46 21 • 69 360 • 536

TP(I/S-0S)20PNBS-5 026407 5 .030 • 0.76 .080 • 2.0 .890 • 22.6 82 • 269 0.14 • 46 21 • 69 440 • 655

TP(I/S-0S)20PNBS-6 026408 6 .030 • 0.76 .080 • 2.0 .925 • 23.5 82 • 269 0.14 • 46 21 • 69 485 • 722

TP(I/S-0S)20PNBS-7 026409 7 .030 • 0.76 .080 • 2.0 .925 • 23.5 82 • 269 0.14 • 46 21 • 69 500 • 744

TP(I/S-0S)20PNBS-8 026410 8 .030 • 0.76 .080 • 2.0 .980 • 24.9 82 • 269 0.14 • 46 21 • 69 550 • 818

TP(I/S-0S)20PNBS-10 026411 10 .030 • 0.76 .080 • 2.0 1.120 • 28.5 82 • 269 0.14 • 46 21 • 69 690 • 1027

TP(I/S-0S)20PNBS-12 026412 12 .030 • 0.76 .080 • 2.0 1.150 • 29.2 82 • 269 0.14 • 46 21 • 69 730 • 1086

TP(I/S-0S)20PNBS-16 026413 16 .030 • 0.76 .080 • 2.0 1.250 • 31.8 82 • 269 0.l4 • 46 21 • 69 885 • 1317

TP(I/S-0S)20PNBS-20 026414 20 .030 • 0.76 .080 • 2.0 1.350 • 34.3 82 • 269 0.14 • 46 21 • 69 1060 • 1577

TP(I/S-0S)20PNBS-24 026415 24 .030 • 0.76 .110 • 2.8 1.545 • 39.2 82 • 269 0.14 • 46 21 • 69 1260 • 1875

18 AWG • 0.96 mm2

Insulation Sheath Cable Diameter Characteristic Cable WeightType Draka Number of Thickness Thickness (nominal) Impedance Inductance Capacitance (approximate)Designation Number Pairs in • mm in • mm in • mm Ω/kft - Ω/km mH/kft • mH/km pF/ft • pF/m Lbs/mft • Kg/km

TP(0S)18PNBS-1 026664 1 .030 • 0.76 .060 • 1.5 .535 • 13.6 73 • 239 0.13 • 43 23 • 75 185 • 275

TP(I/S-0S)18PNBS-2 026417 2 .030 • 0.76 .060 • 1.5 .785 • 19.5 73 • 239 0.13 • 43 23 • 75 350 • 521

TP(I/S-0S)18PNBS-3 026418 3 .030 • 0.76 .060 • 1.5 .845 • 21.5 73 • 239 0.13 • 43 23 • 75 395 • 588

TP(I/S-0S)18PNBS-4 026419 4 .030 • 0.76 .080 • 2.0 .895 • 22.7 73 • 239 0.13 • 43 23 • 75 465 • 692

TP(I/S-0S)18PNBS-5 026420 5 .030 • 0.76 .080 • 2.0 .930 • 23.6 73 • 239 0.13 • 43 23 • 75 505 • 752

TP(I/S-0S)18PNBS-6 026421 6 .030 • 0.76 .080 • 2.0 .990 • 25.2 73 • 239 0.13 • 43 23 • 75 570 • 848

TP(I/S-0S)18PNBS-7 026422 7 .030 • 0.76 .080 • 2.0 1.020 • 25.9 73 • 239 0.13 • 43 23 • 75 605 • 900

TP(I/S-0S)18PNBS-8 026423 8 .030 • 0.76 .080 • 2.0 1.180 • 30.0 73 • 239 0.13 • 43 23 • 75 725 • 1079

TP(I/S-0S)18PNBS-10 026424 10 .030 • 0.76 .080 • 2.0 1.245 • 31.6 73 • 239 0.13 • 43 23 • 75 845 • 1257

TP(I/S-0S)18PNBS-12 026425 12 .030 • 0.76 .080 • 2.0 1.265 • 32.1 73 • 239 0.13 • 43 23 • 75 910 • 1354

TP(I/S-0S)18PNBS-16 026426 16 .030 • 0.76 .110 • 2.8 1.440 • 36.6 73 • 239 0.13 • 43 23 • 75 1135 • 1689

TP(I/S-0S)18PNBS-20 026427 20 .030 • 0.76 .110 • 2.8 1.520 • 38.6 73 • 239 0.13 • 43 23 • 75 1350 • 2009

TP(I/S-0S)18PNBS-24 026428 24 .030 • 0.76 .110 • 2.8 1.760 • 44.7 73 • 239 0.13 • 43 23 • 75 1680 • 2500

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 20 of 62

BOSTRIG™ TYPE P SIGNAL CABLE

individual and overall shielded multipair / armored and sheathed20 & 18 AWG / 600V or 0.6/1kV

DUSA_MOG20_0807

98

Page 106: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG47_0807

www.DrakaMOG.com

BOSTRIG™ TYPE P SIGNAL CABLE

Subject to change without prior notice

Bostrig Type P0807

Page 47 of 62

Individual and overall shielded multi-triad/ unarmoredTYPE P SIGNAL CABLE600V or 0.6/1kV18 & 16 AWG

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an armored andsheathed version.

31 2 4

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair

and the cabled core. The single pair construction has only the overall shield.4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580

(2001). Thickness as shown in tables on opposite page.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC60332-3, Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No.95/00161 (E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured tc BIW Specifying Standard J106

99

Page 107: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 48 of 62

BOSTRIG™ TYPE P SIGNAL CABLE

individual and overall shielded multitriad / unarmored18 & 16 AWG / 0.6/1kV18 AWG • 0.96 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Triads in • mm in • mm in • mm Lbs/mft • Kg/km

TT(0S)18PN-1 1 .030 • 0.76 .060 • 1.5 .360 • 9.1 75 • 111

TT(I/S-0S)18PN-2 026456 2 .030 • 0.76 .060 • 1.5 .605 • 15.4 165 • 246

TT(I/S-0S)18PN-3 026457 3 .030 • 0.76 .060 • 1.5 .640 • 16.3 210 • 313

TT(I/S-0S)18PN-4 026458 4 .030 • 0.76 .060 • 1.5 .705 • 17.9 265 • 394

TT(I/S-0S)18PN-5 026459 5 .030 • 0.76 .060 • 1.5 .775 • 19.7 315 • 469

TT(I/S-0S)18PN-6 026460 6 .030 • 0.76 .080 • 2.0 .880 • 22.4 390 • 580

TT(I/S-0S)18PN-8 026461 8 .030 • 0.76 .080 • 2.0 .955 • 24.5 495 • 737

TT(I/S-0S)18PN-12 026462 12 .030 • 0.76 .080 • 2.0 1.155 • 29.3 715 • 1064

16 AWG • 1.23 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Triads in • mm in • mm in • mm Lbs/mft • Kg/km

TT(0S)16PN-1 026625 1 .030 • 0.76 .060 • 1.5 .370 • 9.4 85 • 126

TT(I/S-0S)16PN-2 026465 2 .030 • 0.76 .060 • 1.5 .630 • 16.0 180 • 268

TT(I/S-0S)16PN-3 026466 3 .030 • 0.76 .060 • 1.5 .670 • 17.0 235 • 350

TT(I/S-0S)16PN-4 026467 4 .030 • 0.76 .060 • 1.5 .740 • 18.8 295 • 439

TT(I/S-0S)16PN-5 026468 5 .030 • 0.76 .060 • 1.5 .815 • 20.7 355 • 528

TT(I/S-0S)16PN-6 026469 6 .030 • 0.76 .080 • 2.0 .915 • 23.1 446 • 662

TT(I/S-0S)16PN-8 026470 8 .030 • 0.76 .080 • 2.0 1.070 • 27.2 625 • 930

TT(I/S-0S)16PN-12 026471 12 .030 • 0.76 .080 • 2.0 1.215 • 30.9 805 • 1198

TT(I/S-0S)16PN-16 026472 16 .030 • 0.76 .080 • 2.0 1.360 • 34.5 1050 • 1563

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

DUSA_MOG48_0807

100

Page 108: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

BOSTRIG™ TYPE P SIGNAL CABLE 600V OR 0.6/1kV

Subject to change without prior notice

Bostrig Type P0807

Page 23 of 62

Individual and overall shielded multi-triad/ armored and sheathedTYPE P SIGNAL CABLE600V or 0.6/1kV18 & 16 AWG

Applications

BostrigTM Type P Marine and Offshore Cable is primarily designed for power, control, signal and instrumentation applications for offshore, land rigs,marine vessels and oil and gas drilling rigs.

Bostrig cables have excellent resistance to oil, abrasion,moisture, sunlight and ester-based mud (Type P-MR).They are suitable for use in Class I, Division I and Zone Iapplications (armored & sheathed) and meet the crushand impact resistance requirements (C&IR) of UL 2225.

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexibledesign. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product is readily available in an unarmored version.

31 2 54 6

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair

and the cabled core. The single pair construction has only the overall shield.4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580

(2001). Thickness as shown on data sheet for unarmored version.5 Armor Braided bronze in accordance with IEEE 1580 (2001).6. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene

as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings

Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC60332-3, Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for600V.

Bostrig Type P cables comply with the Crush and Impact requirements ofUL 2225.

Approvals

ETL/Intertek Testing Services Listed as Marine ShipboardCable in accordance with IEEE 45 (1998), IEEE 1580(2001), UL 1309/CSA245 and the performance requirements of IEC 60092-3.

Det Norske Veritas Type Approval Certificates E8792, E8793, E8794, E8795 and E8796.

American Bureau of Shipping Approval Certificate 03-HS347018C/3-PDA.

Lloyds Registry of Shipping Approval Certificates No. 95/00161(E3) and 95-00162(E3)

Transport Canada Approved AMS400-20-2

Manufactured to BIW Specifying Standard J106

DUSA_MOG23_0807

101

Page 109: Prysmian Draka - Marine & Offshore LV HV Cables

18 AWG • 0.96 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Triads in • mm in • mm in • mm Lbs/mft • Kg/km

TT(0S)18PNBS-1 026473 1 .030 • 0.76 .060 • 1.5 .540 • 13.7 200 • 298

TT(I/S-0S)18PNBS-2 026474 2 .030 • 0.76 .060 • 1.5 .785 • 19.9 360 • 536

TT(I/S-0S)18PNBS-3 026475 3 .030 • 0.76 .060 • 1.5 .850 • 21.6 430 • 640

TT(I/S-0S)18PNBS-4 026476 4 .030 • 0.76 .080 • 2.0 .930 • 23.6 525 • 781

TT(I/S-0S)18PNBS-5 026477 5 .030 • 0.76 .080 • 2.0 .995 • 25.3 590 • 878

TT(I/S-0S)18PNBS-6 026478 6 .030 • 0.76 .080 • 2.0 1.100 • 28.0 715 • 1064

TT(I/S-0S)18PNBS-8 026479 8 .030 • 0.76 .080 • 2.0 1.175 • 29.9 825 • 1228

TT(I/S-0S)18PNBS-12 026480 12 .030 • 0.76 .110 • 2.8 1.440 • 36.6 1180 • 1756

TT(I/S-0S)18PNBS-16 026481 16 .030 • 0.76 .110 • 2.8 1.570 • 39.9 1450 • 2158

16 AWG • 1.23 mm2

Insulation Sheath Cable Diameter Cable WeightType Draka Number of Thickness Thickness (nominal) (approximate)Designation Number Triads in • mm in • mm in • mm Lbs/mft • Kg/km

TT(0S)16PNBS-1 026716 1 .030 • 0.76 .060 • 1.5 .550 • 14.0 210 • 313

TT(I/S-0S)16PNBS-2 026483 2 .030 • 0.76 .060 • 1.5 .810 • 20.6 380 • 566

TT(I/S-0S)16PNBS-3 026484 3 .030 • 0.76 .080 • 2.0 .890 • 22.6 485 • 722

TT(I/S-0S)16PNBS-4 026485 4 .030 • 0.76 .080 • 2.0 .960 • 24.4 570 • 848

TT(I/S-0S)16PNBS-5 026486 5 .030 • 0.76 .080 • 2.0 1.035 • 26.3 645 • 960

TT(I/S-0S)16PNBS-6 026487 6 .030 • 0.76 .080 • 2.0 1.130 • 28.7 770 • 1146

TT(I/S-0S)16PNBS-8 026488 8 .030 • 0.76 .080 • 2.0 1.290 • 32.8 950 • 1414

TT(I/S-0S)16PNBS-12 026489 12 .030 • 0.76 .110 • 2.8 1.495 • 38.0 1280 • 1905

TT(I/S-0S)16PNBS-16 026490 16 .030 • 0.76 .110 • 2.8 1.640 • 41.7 1565 • 2329

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 24 of 62

BOSTRIG™ TYPE P SIGNAL CABLE

individual and overall shielded multi-triad / armored and sheathed18 & 16 AWG / 0.6/1kV

DUSA_MOG24_0807

102

Page 110: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG57_0807

www.DrakaMOG.com

BOSTRIG™ TYPE P-VFD POWER CABLE 2000V

Subject to change without prior notice

Bostrig Type P0807

Page 57 of 62

Shielded three conductor / unarmored orarmored and sheathed

TYPE P VFD CABLE2000V1/0 AWG to 777 MCM

Construction

1. Conductors Soft annealed tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001). Insulation is printed with phase markings as required.

3. Ground Conductors All Bostrig Type P-VFD Cables listed in this specification sheet are built using system grounds equal to the aggregte cross-section of a phase conductor and can be in contact withor isolated from the overall shield. A system ground is REQUIRED for supplying power from the switchboard to the inverter and then to the motor. If the VFD cable is only being used between the motor and the inverter, a cable with a lesser ground can be ordered.

4. Shield Braided tinner cooper for 95% coverage.5. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580

(2001).6. Armor (Optional) Braided bronze in accordance with IEEE 1580 (2001).

7. Sheath (Optional) Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Applications

BostrigTM Type P shielded three conductor VFD Marine and Offshore Cable is designed specifically for use with variable frequency AC motor drives. This cable is ETL listed per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

Bostrig cables have excellent resistance to oil, abrasion, moisture and sunlight and ester-based mud (Type P-MR).They are suitable for use in Class I, Division I and Zone I applications (armored & sheathed) and meet the crush andimpact resistance requirements (C&IR) of UL 2225 and complies with UL 1277 Type TC exposed runs requirements.

The standard insulation has a continuous operating temperature of 125ºC allowing for higher ampacity levels. Larger diameter cables carry a new flexible design. They satisfy Transport Canada’s cold bend at -40ºC and cold impact at -35ºC (CSA C 22.2 No. 0.3).

This product can be manufactured in an unarmored or armored and sheathed version.

Features

• Low smoke/zero halogen construction meets appropriate IEEE and IEC standards for fire, smoke, and toxicity• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Gigabit Ethernet 802.3Z compliant

RatingsMeets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3, Category A.

Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for 2000V.

Type approved by DNV, ABS, Lloyds and Transport Canada.

Bostrig Type P cables comply to UL 1277 Type TC exposed runs requirements and with the crush and impact requirements of UL 2225.

1 2 3 4 5 6 7

103

Page 111: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG58_0807

unarmoredSheath Cable Diameter Calculated Ampacity† Cable Weight

Type Draka Conductor Size Ground Size Thickness (nominal) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

TP(OBS)N-1/0 036028 1/0 • 56.3 5 AWG •18.6 n/a 1.53 • 38.9 0.09 • 0.3 190 • 623 156 • 164 • 176 2280 • 3393

TP(OBS)N-2/0 036029 2/0 • 66.5 4 AWG • 21.5 n/a 1.63 • 41.4 0.09 • 0.3 212 • 695 175 • 186 • 201 2640 • 3928

TP(OBS)N-4/0 036030 4/0 • 112.6 1 AWG • 56.3 n/a 2.09 • 53.1 0.09 • 0.3 259 • 850 241 • 252 • 270 4480 • 6666

TP(OBS)N-262 036031 262 • 133.0 1 AWG • 56.3 n/a 2.23 • 56.6 0.09 • 0.3 247 • 810 267 • 294 • 315 5050 • 7514

TP(OBS)N-313 036032 313 • 158.6 110 AWG • 18.6 n/a 2.36 • 60.0 0.08 • 0.2 270 • 886 298 • 321 • 344 5860 • 8720

TP(OBS)N-373 036033 373 • 189.3 210 AWG • 61.5 n/a 2.56 • 65.0 0.08 • 0.2 292 • 958 333 • 361 • 387 6950 • 10342

TP(OBS)N-444 036034 444 • 225.1 310 AWG • 92.1 n/a 2.87 • 72.9 0.08 • 0.2 318 • 1043 371 • 411 • 440 8660 • 12886

TP(OBS)N-535 036035 535 • 271.2 310 AWG • 92.1 n/a 3.03 • 77.0 0.09 • 0.3 291 • 954 417 • 443 • 475 9700 • 14437

TP(OBS)N-646 036036 646 • 327.5 410 AWG • 112.6 n/a 3.18 • 80.8 0.09 • 0.3 314 • 1030 469 • 516 • 553 11400 • 16963

TP(OBS)N-777 036037 777 • 393.8 262 KCMIL • 133.0 n/a 3.52 • 89.4 0.09 • 0.3 345 • 1132 528 • 582 • 602 13520 • 20118

armored and sheathedSheath Cable Diameter Calculated Ampacity† Cable Weight

Type Draka Conductor Size Ground Size Thickness (nominal) Inductance Capacitance (measured @ ºC) (approximate)Designation Number AWG/MCM • mm2 AWG/MCM • mm2 in • mm in • mm Ω/kft - Ω/km pF/ft • pF/m 95 • 100 • 110 Lbs/mft • Kg/km

TP(OBS)NBS-1/0 036038 4/0 • 112.6 5 AWG •18.6 .11 • 2.8 1.82 • 46.2 0.09 • 0.3 190 • 623 156 • 164 • 176 3020 • 4494

TP(OBS)NBS-2/0 036039 4/0 • 112.6 4 AWG • 21.5 .11 • 2.8 1.92 • 48.8 0.09 • 0.3 212 • 695 175 • 188 • 201 3420 • 5089

TP(OBS)NBS-4/0 036040 4/0 • 112.6 1 AWG • 56.3 .11 • 2.8 2.38 • 60.4 0.09 • 0.3 259 • 850 241 • 252 • 270 5510 • 8199

TP(OBS)NBS-262 036041 262 • 133.1 1 AWG • 56.3 .11 • 2.8 2.52 • 64.0 0.09 • 0.3 247 • 810 267 • 294 • 315 6130 • 9121

TP(OBS)NBS-313 036042 313 • 158.7 110 AWG • 18.6 .11 • 2.8 2.65 • 67.3 0.08 • 0.2 270 • 886 298 • 321 • 344 7010 • 10431

TP(OBS)NBS-373 036043 373 • 189.2 210 AWG • 61.5 .14 • 3.6 2.90 • 73.7 0.08 • 0.2 292 • 958 333 • 361 • 387 8360 • 12440

TP(OBS)NBS-444 036044 444 • 225.2 310 AWG • 92.1 .14 • 3.6 3.21 • 81.5 0.08 • 0.2 318 • 1043 371 • 411 • 440 10230 • 15222

TP(OBS)NBS-535 036045 535 • 271.3 310 AWG • 92.1 .14 • 3.6 3.37 • 85.6 0.09 • 0.3 291 • 954 417 • 443 • 475 11350 • 16889

TP(OBS)NBS-646 036046 646 • 327.5 410 AWG • 112.6 .14 • 3.6 3.52 • 89.4 0.09 • 0.3 314 • 1030 469 • 516 • 553 13130 • 19537

TP(OBS)NBS-777 036047 777 • 394.2 262 KCMIL • 133.0 .14 • 3.6 3.86 • 98.0 0.09 • 0.3 345 • 1132 528 • 582 • 602 15420 • 22944

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,This information is not meant to replace the information in the appropriate and applicable standard or code.†Ampacity based on 45ºC ambient temperature: 95ºC values based on ABS MODU Rules Table 6 - 1OOºC values based on IEEE-45 Table 25 - 11 O’C values based on IEEE-45Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

www.DrakaMOG.comSubject to change without prior notice

Bostrig Type P0807

Page 58 of 62

BOSTRIG™ TYPE P-VFD POWER CABLE

shielded three conductor / unarmored or armored and sheathed1/0 AWG to 777 MCM / 2000V

PHASE CONDUCTOR (3)

SYSTEM GROUND (3)

FILLERS (AS REQUIRED)

MYLAR TAPE

BRAIDED SHIELD

JACKET

BRAIDED ARMOR

SHEATH

104

Page 112: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

15K

V

BOSTRIG MHV-15 CABLESingle Conductor Power (Type N Jacket)15 kV (IEC 12/20 kV) Shielded - 133% LevelUnarmored

ApplicationBostrig MHV-15 single conductor 15,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c 15 kV (IEC 12/20 kV) Shielded - 133% Level 108

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-15-2 2 30.7 150/24 .220 5.59 .080 2.03 1.130 28.70 790 1175MHV-15-1 1 46.0 225/24 .220 5.59 .080 2.03 1.200 30.48 950 1414MHV-15-1/0 1/0 56.3 275/24 .220 5.59 .080 2.03 1.250 31.75 1050 1563MHV-15-2/0 2/0 66.5 325/24 .220 5.59 .080 2.03 1.270 32.26 1150 1711MHV-15-3/0 3/0 92.1 450/24 .220 5.59 .085 2.16 1.400 35.56 1430 2128MHV-15-4/0 4/0 112.6 550/24 .220 5.59 .085 2.16 1.450 36.83 1600 2381MHV-15-262 262 133.0 650/24 .220 5.59 .085 2.16 1.500 38.10 1760 2619MHV-15-313 313 158.6 775/24 .220 5.59 .090 2.29 1.580 40.13 2000 2976MHV-15-373 373 189.3 925/24 .220 5.59 .090 2.29 1.660 42.16 2250 3348MHV-15-444 444 225.1 1100/24 .220 5.59 .110 2.80 1.770 44.96 2620 3899MHV-15-535 535 271.2 1325/24 .220 5.59 .110 2.80 1.860 47.24 3000 4464MHV-15-646 646 327.5 1600/24 .220 5.59 .110 2.80 1.980 50.29 3500 5209MHV-15-777 777 393.8 1925/24 .220 5.59 .110 2.80 2.070 52.58 4000 5953MHV-15-1111 1111 562.8 2750/24 .220 5.59 .115 2.92 2.300 58.42 5300 7887

Marine & OffshoreProduct Specification J-124IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the metallic braid shield.Thickness as shown in table below.

TestsMeets applicable test requirements in IEC 60502, IEEE 45-1998 &1993 (draft), ICEA S-68-516, UL 1072, J-124, and flame test inIEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV15_108_109_2_00105

Page 113: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

15K

V

BOSTRIG MHV-15 CABLESingle Conductor Power (Type N Jacket)15 kV (IEC 8.7/15 kV) Shielded - 100% LevelUnarmored

ApplicationBostrig MHV-15 single conductor 15,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c - 15 kV (IEC 8.7/15 kV) Shielded - 100% Level 106

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-15-2 2 30.7 150/24 .177 4.50 .080 2.03 1.050 26.67 700 1042MHV-15-1 1 46.0 225/24 .177 4.50 .080 2.03 1.110 28.19 860 1280MHV-15-1/0 1/0 56.3 275/24 .177 4.50 .080 2.03 1.170 29.72 960 1429MHV-15-2/0 2/0 66.5 325/24 .177 4.50 .080 2.03 1.190 30.23 1040 1548MHV-15-3/0 3/0 92.1 450/24 .177 4.50 .080 2.03 1.310 33.27 1310 1950MHV-15-4/0 4/0 112.6 550/24 .177 4.50 .080 2.03 1.370 34.80 1480 2202MHV-15-262 262 133.0 650/24 .177 4.50 .085 2.16 1.420 36.07 1650 2455MHV-15-313 313 158.6 775/24 .177 4.50 .085 2.16 1.480 37.59 1860 2768MHV-15-373 373 189.3 925/24 .177 4.50 .090 2.29 1.560 39.62 2120 3155MHV-15-444 444 225.1 1100/24 .177 4.50 .090 2.29 1.630 41.10 2410 3586MHV-15-535 535 271.2 1325/24 .177 4.50 .110 2.80 1.760 44.71 2850 4241MHV-15-646 646 327.5 1600/24 .177 4.50 .110 2.80 1.870 47.50 3270 4866MHV-15-777 777 393.8 1925/24 .177 4.50 .110 2.80 2.970 50.04 3800 5655MHV-15-1111 1111 562.8 2750/24 .177 4.50 .110 2.80 2.190 55.63 5100 7590

Marine & OffshoreProduct Specification J-120IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the metallic braid shield.Thickness as shown in table below.

TestsMeets applicable test requirements in IEC 60502, IEC 60092-354,IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-120, andflame test in IEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV15_106_107_2_00106

Page 114: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

15K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV-15B CABLESingle Conductor Power (Type N Jacket) 15 kV - Shielded - 133% Level Armored Only

ApplicationBostrig MHV-15B single conductor 15,000 volt shielded cables are suitable for use in com-mercial marine applications, MODU’s, and platforms where flame retardant cables havingexcellent physical and electrical properties are required. The cables have excellent resistance tooils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available witheither a fully insulated grounding conductor or an un-insulated grounding conductor evenlydistributed in the interstices.

1/c- 15 kV Shielded - 133% Level 174

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-15B-2 2 30.7 150/24 .220 5.59 .080 2.03 1.190 30.23 970 1444MHV-15B-l 1 46.0 225/24 .220 5.59 .080 2.03 1.260 32.00 1130 1756MHV-15B-l/0 1/0 56.3 275/24 .220 5.59 .080 2.03 1.310 33.27 1280 1905MHV-15B-2/0 2/0 66.5 325/24 .220 5.59 .080 2.03 1.330 33.78 1380 2054MHV-15B-3/0 3/0 92.1 450/24 .220 5.59 .085 2.16 1.460 37.08 1680 2500MHV-15B-4/0 4/0 112.6 550/24 .220 5.59 .085 2.16 1.510 38.35 1870 2783MHV-15B-262 262 133.0 650/24 .220 5.59 .085 2.16 1.560 39.62 2050 3051MHV-15B-313 313 158.6 775/24 .220 5.59 .090 2.29 1.640 41.66 2300 3423MHV-15B-373 373 189.3 925/24 .220 5.59 .090 2.29 1.720 43.69 2550 3795MHV-15B-444 444 225.1 1100/24 .220 5.59 .110 2.80 1.830 46.48 2950 4390MHV-15B-535 535 271.2 1325/24 .220 5.59 .110 2.80 1.920 48.77 3350 4985MHV-15B-646 646 327.5 1600/24 .220 5.59 .110 2.80 2.040 51.82 3900 5804MHV-15B-777 777 393.8 1925/24 .220 5.59 .110 2.80 2.130 54.10 4400 6548MHV-15B-1111 1111 562.8 2750/24 .220 5.59 .115 2.92 2.360 59.94 5750 8557

Marine & OffshoreProduct Specification J-124IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the metallic braid shield.Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEEE 45-1998 & 1993 (draft),ICEA S-68-516, UL 1072, J-124, and flame test in IEC 60332-3, catA, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV15B_174_2_00107

Page 115: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

15K

V

BOSTRIG MHV-15B CABLESingle Conductor Power (Type N Jacket) 15 kV - Shielded - 100% Level Armored Only

ApplicationBostrig MHV-15B single conductor 15,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c- 15 kV Shielded - 100% Level 171

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-15B-2 2 30.7 150/24 .177 4.50 .080 2.03 1.110 28.19 860 1280MHV-15B-1 1 46.0 225/24 .177 4.50 .080 2.03 1.170 29.72 1040 1547MHV-15B-1/0 1/0 56.3 275/24 .177 4.50 .080 2.03 1.230 31.24 1140 1697MHV-15B-2/0 2/0 66.5 325/24 .177 4.50 .080 2.03 1.250 31.75 1220 1816MHV-15B-3/0 3/0 92.1 450/24 .177 4.50 .080 2.03 1.370 34.80 1550 2307MHV-15B-4/0 4/0 112.6 550/24 .177 4.50 .080 2.03 1.430 36.32 1720 2560MHV-15B-262 262 133.0 650/24 .177 4.50 .085 2.16 1.480 37.59 1900 2828MHV-15B-313 313 158.6 775/24 .177 4.50 .085 2.16 1.540 39.12 2150 3200MHV-15B-373 373 189.3 925/24 .177 4.50 .090 2.29 1.620 41.15 2400 3572MHV-15B-444 444 225.1 1100/24 .177 4.50 .090 2.29 1.690 42.93 2750 4092MHV-15B-535 535 271.2 1325/24 .177 4.50 .110 2.80 1.820 46.23 3200 4762MHV-15B-646 646 327.5 1600/24 .177 4.50 .110 2.80 1.930 49.02 3650 5432MHV-15B-777 777 393.8 1925/24 .177 4.50 .110 2.80 2.030 51.56 4150 6176MHV-15B-1111 1111 562.8 2750/24 .177 4.50 .110 2.80 2.250 57.15 5500 8185

Marine & OffshoreProduct Specification J-120IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the cable core. Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEEE 45-1998 & 1993 (draft),ICEA S-68-516, UL 1072, J-120 and flame test in IEC 60332-3, catA, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV5BS_171_2_00108

Page 116: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

15K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV-15BS CABLESingle Conductor Power (Type N Jacket & Sheath) 15 kV (IEC 12/20 kV) Shielded - 133% LevelArmored and Sheathed

ApplicationBostrig MHV-15BS single conductor 15,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, thesecables can be supplied without the sheath over the armor.

1/c 15 kV (IEC 12/20 kV) Shielded - 133% Level 109

BIW Insulation Jacket/Sheath NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-15BS-2 2 30.7 150/24 .220 5.59 .080/.080 2.03/2.03 1.360 34.54 1200 1786MHV-15BS-1 1 46.0 225/24 .220 5.59 .080/.080 2.03/2.03 1.420 36.07 1400 2083MHV-15BS-l/0 1/0 56.3 275/24 .220 5.59 .080/.080 2.03/2.03 1.470 37.34 1500 2232MHV-15BS-2/0 2/0 66.5 325/24 .220 5.59 .080/.080 2.03/2.03 1.490 37.85 1600 2381MHV-15BS-3/0 3/0 92.1 450/24 .220 5.59 .085/.080 2.16/2.03 1.630 41.40 1920 2857MHV-15BS-4/0 4/0 112.6 550/24 .220 5.59 .085/.080 2.16/2.03 1.680 42.67 2100 3125MHV-15BS-262 262 133.0 650/24 .220 5.59 .085/.080 2.16/2.80 1.790 45.47 2400 3571MHV-15BS-313 313 158.6 775/24 .220 5.59 .090/.110 2.29/2.80 1.870 47.59 2650 3943MHV-15BS-373 373 189.3 925/24 .220 5.59 .090/.110 2.29/2.80 1.940 49.28 2950 4390MHV-15BS-444 444 225.1 1100/24 .220 5.59 .110/.110 2.80/2.80 2.050 52.07 3400 5060MHV-15BS-535 535 271.2 1325/24 .220 5.59 .110/.110. 2.80/2.80 2.150 54.61 3800 5655MHV-15BS-646 646 327.5 1600/24 .220 5.59 .110/.110 2.80/2.80 2.260 57.40 4300 6399MHV-15BS-777 777 393.8 1925/24 .220 5.59 .110/.110 2.80/2.80 2.360 59.94 4800 7143MHV-15BS-1111 1111 562.8 2750/24 .220 5.59 .115/.110 2.92/2.80 2.580 65.53 6200 9227

Marine & OffshoreProduct Specification J-124IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

Jacket and SheathBoth the inner jacket applied over the cabled core and outer sheathover the armor are flame retardant, heavy duty arctic Neoprene.Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEC 60502, IEEE 45-1998 &1993 (draft), ICEA S-68-516, UL 1072, J-124, and flame test inIEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV15_108_109_2_00109

Page 117: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

15K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV-15BS CABLESingle Conductor Power (Type N Jacket & Sheath)15 kV (IEC 8.7/15 kV) Shielded - 100% LevelArmored and Sheathed

ApplicationBostrig MHV-15BS single conductor 15,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, thesecables can be supplied without the sheath over the armor.

1/c - 15 kV (IEC 8.7/15kV) Shielded - 100% Level 107

BIW Insulation Jacket/Sheath NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-15BS-2 2 30.7 150/24 .177 4.50 .080/.080 2.03/2.03 1.270 32.26 1060 1577MHV-15BS-1 1 46.0 225/24 .177 4.50 .080/.080 2.03/2.03 1.330 33.78 1240 1845MHV-15BS-1/0 1/0 56.3 275/24 .177 4.50 .080/.080 2.03/2.03 1.390 35.31 1360 2024MHV-15BS-2/0 2/0 66.5 325/24 .177 4.50 .080/.080 2.03/2.03 1.410 35.81 1440 2143MHV-15BS-3/0 3/0 92.1 450/24 .177 4.50 .080/.080 2.03/2.03 1.530 38.86 1780 2649MHV-15BS-4/0 4/0 112.6 550/24 .177 4.50 .080/.080 2.03/2.03 1.580 40.13 1960 2917MHV-15BS-262 262 133.0 650/24 .177 4.50 .085/.080 2.16/2.03 1.640 41.66 2140 3185MHV-15BS-313 313 158.6 775/24 .177 4.50 .085/.110 2.16/2.80 1.760 44.70 2500 3720MHV-15BS-373 373 189.3 925/24 .177 4.50 .090/.110 2.29/2.80 1.850 46.99 2790 4152MHV-15BS-444 444 225.1 1100/24 .177 4.50 .090/.110 2.29/2.80 1.920 48.77 3100 4613MHV-15BS-535 535 271.2 1325/24 .177 4.50 .110/.110 2.80/2.80 2.050 52.07 3600 5357MHV-15BS-646 646 327.5 1600/24 .177 4.50 .110/.110 2.80/2.80 2.150 54.61 4050 6027MHV-15BS-777 777 393.8 1925/24 .177 4.50 .110/.110 2.80/2.80 2.260 57.40 4620 6875MHV-15BS-1111 1111 562.8 2750/24 .177 4.50 .110/.110 2.80/2.80 2.480 62.99 6000 8929

Marine & OffshoreProduct Specification J-120IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

Jacket and SheathBoth the inner jacket applied over the metallic braid shield and outersheath over the armor are flame retardant, heavy duty arcticNeoprene. Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEC 60502, IEC 60092-354,IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-120, andflame test in IEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in conformanceto IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Typeapproved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV15_106_107_2_00110

Page 118: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

5K

V

BOSTRIG MHV-5 CABLESingle Conductor Power (Type N Jacket) 5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% LevelUnarmored

ApplicationBostrig MHV-5 single conductor 5,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight

1/c - 5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level 100

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-5-8 8 7.57 37/24 .090 2.29 .060 1.53 .660 16.76 280 417MHV-5-6 6 12.5 61/24 .090 2.29 .060 1.53 .720 18.29 340 506MHV-5-5 5 18.6 91/24 .090 2.29 .060 1.53 .750 19.05 400 595MHV-5-4 4 21.5 105/24 .090 2.29 .060 1.53 .790 20.07 430 640MHV-5-2 2 30.7 150/24 .090 2.29 .060 1.53 .850 21.59 520 774MHV-5-1 1 46.0 225/24 .090 2.29 .080 2.03 .950 24.13 700 1042MHV-5-1/0 1/0 56.3 275/24 .090 2.29 .080 2.03 1.000 25.54 790 1176MHV-5-2/0 2/0 66.5 325/24 .090 2.29 .080 2.03 1.020 25.91 860 1280MHV-5-3/0 3/0 92.1 450/24 .095 2.40 .080 2.03 1.130 28.70 1100 1637MHV-5-4/0 4/0 112.6 550/24 .095 2.40 .080 2.03 1.170 29.72 1250 1860MHV-5-262 262 133.0 650/24 .095 2.40 .080 2.03 1.220 30.99 1400 2083MHV-5-313 313 158.6 775/24 .095 2.40 .080 2.03 1.310 33.27 1650 2456MHV-5-373 373 189.3 925/24 .095 2.40 .080 2.03 1.380 35.05 1900 2828MHV-5-444 444 225.1 1100/24 .095 2.40 .085 2.16 1.460 37.08 2200 3274MHV-5-535 535 271.2 1325/24 .095 2.40 .090 2.29 1.560 39.62 2550 3795MHV-5-646 646 327.5 1600/24 .103 2.60 .095 2.42 1.682 42.67 3000 4465MHV-5-777 777 393.8 1925/24 .103 2.60 .110 2.80 1.800 45.72 3500 5209MHV-5-1111 1111 562.8 2750/24 .110 2.80 .110 2.80 2.060 52.32 4800 7143

Marine & OffshoreProduct Specification J-121IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the metallic braid shield.Thickness as shown in table below.

TestsMeets applicable test requirements in IEC 60502, IEEE 45-1998 &1993 (draft), ICEA S-68-516, UL 1072, J-121, and flame test inIEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV5_100_101_2_00111

Page 119: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

5K

V

BOSTRIG MHV-5B CABLESingle Conductor Power (Type N Jacket) 5 kV - Shielded - 100% or 133% Level Armored Only

ApplicationBostrig MHV-5B single conductor 5,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c- 5 kV Shielded - 100% or 133% Level 170

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-5B-8 8 7.57 37/24 .090 2.29 .060 1.53 .720 18.29 380 566MHV-5B-6 6 12.5 61/24 .090 2.29 .060 1.53 .780 19.81 450 670MHV-5B-5 5 18.6 91/24 .090 2.29 .060 1.53 .810 20.57 510 759MHV-5B-4 4 21.5 105/24 .090 2.29 .060 1.53 .850 21.59 550 818MHV-5B-2 2 30.7 150/24 .090 2.29 .060 1.53 .910 23.11 650 967MHV-5B-1 1 46.0 225/24 .090 2.29 .080 2.03 1.010 25.65 840 1250MHV-5B-1/0 1/0 56.3 275/24 .090 2.29 .080 2.03 1.060 26.92 940 1399MHV-5B-2/0 2/0 66.5 325/24 .090 2.29 .080 2.03 1.080 27.43 1020 1518MHV-5B-3/0 3/0 92.1 450/24 .095 2.40 .080 2.03 1.190 30.23 1270 1890MHV-5B-4/0 4/0 112.6 550/24 .095 2.40 .080 2.03 1.230 31.24 1430 2128MHV-5B-262 262 133.0 650/24 .095 2.40 .080 2.03 1.280 32.51 1620 2411MHV-5B-313 313 158.6 775/24 .095 2.40 .080 2.03 1.370 34.80 1840 2738MHV-5B-373 373 189.3 925/24 .095 2.40 .080 2.03 1.440 36.58 2150 3200MHV-5B-444 444 225.1 1100/24 .095 2.40 .085 2.16 1.520 38.61 2450 3646MHV-5B-535 535 271.2 1325/24 .095 2.40 .090 2.16 1.620 41.15 2850 4241MHV-5B-646 646 327.5 1600/24 .103 2.60 .095 2.42 1.740 44.20 3300 4911MHV-5B-777 777 393.8 1925/24 .103 2.60 .110 2.80 1.860 47.25 3850 5729

Marine & OffshoreProduct Specification J-121IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the metallic braid shield.Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEEE 45-1998 & 1993 (draft),ICEA S-68-516, UL 1072, J-121 and flame test in IEC 60332-3, catA, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV5B_170_2_00112

Page 120: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

5K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV-5BS CABLESingle Conductor Power (Type N Jacket & Sheath) 5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level Armored and Sheathed

ApplicationBostrig MHV-5BS single conductor 5,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, thesecables can be supplied without the sheath over the armor.

Marine & OffshoreProduct Specification J-121IEC–IEEE–UL

ConductorSoft annealed tinned copper per.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

Jacket and SheathBoth the inner jacket applied over the metallic braid shield and outersheath over the armor are flame retardant, heavy duty arctic Neoprene.Thickness as shown in table below.

ArmorBraided Bronze in accordance with IEEE 45-1998 & 1993 (draft).

TestsMeets applicable test requirements in IEC 60502, IEEE 45-1998 &1993 (draft), ICEA S-68-516, UL 1072, J-121, and flame test in IEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in conformanceto IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Typeapproved by DNV, ABS and LRS.

1/c - 5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level 101

BIW Insulation Jacket/Sheath NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-5BS-8 8 7.57 37/24 .090 2.29 .060/.060 1.53/1.53 .840 21.34 470 700MHV-5BS-6 6 12.5 61/24 .090 2.29 .060/.080 1.53/2.03 .940 23.88 580 863MHV-5BS-5 5 18.6 91/24 .090 2.29 .060/.080 1.53/2.03 .970 24.64 650 967MHV-5BS-4 4 21.5 105/24 .090 2.29 .060/.080 1.53/2.03 1.010 25.65 700 1042MHV-5BS-2 2 30.7 150/24 .090 2.29 .060/.080 1.53/2.03 1.080 27.43 800 1191MHV-5BS-l 1 46.0 225/24 .090 2.29 .080/.080 2.03/2.03 1.170 29.72 1010 1503MHV-5BS-l/0 1/0 56.3 275/24 .090 2.29 .080/.080 2.03/2.03 1.220 30.99 1120 1667MHV-5BS-2/0 2/0 66.5 325/24 .090 2.29 .080/.080 2.03/2.03 1.240 31.50 1210 1801MHV-5BS-3/0 3/0 92.1 450/24 .095 2.40 .080/.080 2.03/2.03 1.350 34.29 1470 2188MHV-5BS-4/0 4/0 112.6 550/24 .095 2.40 .080/.080 2.03/2.03 1.390 35.31 1630 2426MHV-5BS-262 262 133.0 650/24 .095 2.40 .080/.080 2.03/2.03 1.440 36.58 1850 2753MHV-5BS-313 313 158.6 775/24 .095 2.40 .080/.080 2.03/2.03 1.530 38.86 2100 3125MHV-5BS-373 373 189.3 925/24 .095 2.40 .080/.080 2.03/2.03 1.600 40.64 2400 3572MHV-5BS-444 444 225.1 1100/24 .095 2.40 .085/.080 2.16/2.03 1.690 42.93 2700 4018MHV-5BS-535 535 271.2 1325/24 .095 2.40 .090/.110 2.29/2.03 1.840 46.74 3200 4762MHV-5BS-646 646 327.5 1600/24 .103 2.60 .095/.110 2.42/2.80 1.960 49.78 3700 5506MHV-5BS-777 777 393.8 1925/24 .103 2.60 .110/.110 2.80/2.80 2.090 53.09 4300 6399MHV-5BS-l111 1111 562.8 2750/24 .110 2.80 .110/.110 2.80/2.80 2.340 59.44 5700 8483

ISO9001QSC3497

BG_MHV5_100_101_2_00113

Page 121: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

8K

V

BOSTRIG MHV-8 CABLESingle Conductor Power (Type N Jacket) 8 kV (IEC 3.6/6 kV) Shielded - 100% Level Unarmored

ApplicationBostrig MHV-8 single conductor 8,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c 8 kV (IEC 3.6/6 kV) Shielded - 100% Level 102

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-8-6 6 12.5 61/24 .118 3.00 .060 1.53 .770 19.56 370 551MHV-8-5 5 18.6 91/24 .118 3.00 .060 1.53 .810 20.57 430 640MHV-8-4 4 21.5 105/24 .118 3.00 .060 1.53 .830 21.08 470 700MHV-8-2 2 30.7 150/24 .118 3.00 .080 2.03 .930 23.62 590 878MHV-8-1 1 46.0 225/24 .118 3.00 .080 2.03 .990 25.15 730 1086MHV-8-1/0 1/0 56.3 275/24 .118 3.00 .080 2.03 1.050 26.67 820 1220MHV-8-2/0 2/0 66.5 325/24 .118 3.00 .080 2.03 1.060 26.92 900 1339MHV-8-3/0 3/0 92.1 450/24 .118 3.00 .080 2.03 1.170 29.72 1150 1711MHV-8-4/0 4/0 112.6 550/24 .118 3.00 .080 2.03 1.220 30.99 1300 1935MHV-8-262 262 133.0 650/24 .118 3.00 .080 2.03 1.270 32.26 1450 2158MHV-8-313 313 158.6 775/24 .118 3.00 .080 2.03 1.360 34.54 1700 2530MHV-8-373 373 189.3 925/24 .118 3.00 .085 2.16 1.440 36.58 1950 2902MHV-8-444 444 225.1 1100/24 .118 3.00 .085 2.16 1.500 38.10 2250 3348MHV-8-535 535 271.2 1325/24 .118 3.00 .090 2.29 1.600 40.64 2600 3869MHV-8-646 646 327.5 1600/24 .118 3.00 .110 2.80 1.740 44.20 3100 4613MHV-8-777 777 393.8 1925/24 .118 3.00 .110 2.80 1.840 46.74 3600 5357MHV-8-1111 1111 562.8 2750/24 .118 3.20 .110 2.80 2.090 53.09 4900 7292

Marine & OffshoreProduct Specification J-122IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the metallic braid shield.Thickness as shown in table below.

TestsMeets applicable test requirements in IEC 60502, IEC 60092-354,IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-122 andFlame test in IEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV8_102_103_2_00114

Page 122: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

8K

V

BOSTRIG MHV-8 CABLESingle Conductor Power (Type N Jacket)8 kV (IEC 6/10 kV) Shielded - 133% LevelUnarmored

ApplicationBostrig MHV-8 single conductor 8,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c - 8 kV (IEC 6/10 kv) Shielded - 133% Level 104

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-8-5 5 18.6 91/24 .140 3.56 .080 2.03 .890 22.61 510 759MHV-8-4 4 21.5 105/24 .140 3.56 .080 2.03 .920 23.37 540 804MHV-8-2 2 30.7 150/24 .140 3.56 .080 2.03 .980 24.89 640 952MHV-8-1 1 46.0 225/24 .140 3.56 .080 2.03 1.050 26.67 770 1146MHV-8-1/0 1/0 56.3 275/24 .140 3.56 .080 2.03 1.100 27.94 865 1287MHV-8-2/0 2/0 66.5 325/24 .140 3.56 .080 2.03 1.120 28.45 950 1414MHV-8-3/0 3/0 92.1 450/24 .140 3.56 .080 2.03 1.220 30.99 1200 1786MHV-8-4/0 4/0 112.6 550/24 .140 3.56 .080 2.03 1.280 32.51 1350 2009MHV-8-262 262 133.0 650/24 .140 3.56 .080 2.03/ 1.350 34.29 1550 2307MHV-8-313 313 158.6 775/24 .140 3.56 .085 2.16 1.420 36.07 1750 2604MHV-8-373 373 189.3 925/24 .140 3.56 .085 2.16 1.480 37.59 2000 2976MHV-8-444 444 225.1 1100/24 .140 3.56 .090 2.29/ 1.560 39.62 2300 3423MHV-8-535 535 271.2 1325/24 .140 3.56 .090 2.29 1.650 41.91 2650 3944MHV-8-646 646 327.5 1600/24 .140 3.56 .110 2.80 1.800 45.72 3150 4688MHV-8-777 777 393.8 1925/24 .140 3.56 .110 2.80 1.910 48.51 3700 5506MHV-8-1111 1111 562.8 2750/24 .140 3.56 .110 2.80 2.130 54.10 4950 7366

Marine & OffshoreProduct Specification J-123IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the cable core.Thickness as shown in table below.

TestsMeets applicable test requirements in IEC 60502, IEC 60092-354,IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-123 andFlame test in IEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in conformanceto IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Typeapproved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV8_104_105_2_00115

Page 123: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

8K

V

BOSTRIG MHV-8B CABLESingle Conductor Power (Type N Jacket) 8 kV - Shielded - 100% Level Armored Only

ApplicationBostrig MHV-8B single conductor 8,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c - 8 kV Shielded - 100% Level 172

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-8B-6 6 12.5 61/24 .118 3.00 .060 1.53 .830 21.08 500 744MHV-8B-5 5 18.6 91/24 .118 3.00 .060 1.53 .870 22.10 560 833MHV-8B-4 4 21.5 105/24 .118 3.00 .065 1.53 .890 22.61 600 893MHV-8B-2 2 30.7 150/24 .118 3.00 .080 2.03 .990 25.15 730 1086MHV-8B-1 1 46.0 225/24 .118 3.00 .080 2.03 1.050 26.67 880 1309MHV-8B-l/0 1/0 56.3 275/24 .118 3.00 .080 2.03 1.110 28.19 990 1473MHV-8B-2/0 2/0 66.5 325/24 .118 3.00 .080 2.03 1.120 28.45 1070 1592MHV-8B-3/0 3/0 92.1 450/24 .118 3.00 .080 2.03 1.230 31.24 1350 2009MHV-8B-4/0 4/0 112.6 550/24 .118 3.00 .080 2.03 1.280 32.51 1550 2307MHV-8B-262 262 133.0 650/24 .118 3.00 .080 2.03 1.330 33.78 1700 2530MHV-8B-313 313 158.6 775/24 .118 3.00 .080 2.03 1.420 36.07 1950 2902MHV-8B-373 373 189.3 925/24 .118 3.00 .085 2.16 1.500 38.10 2200 3274MHV-8B-444 444 225.1 1100/24 .118 3.00 .085 2.16 1.560 39.62 2500 3720MHV-8B-535 535 271.2 1325/24 .118 3.00 .090 2.29 1.660 42.17 2900 4316MHV-8B-646 646 327.5 1600/24 .118 3.00 .110 2.80 1.800 45.72 3400 5060MHV-8B-777 777 393.8 1925/24 .118 3.00 .110 2.80 1.900 48.26 3900 5804MHV-8B-1111 1111 562.8 2750/24 .126 3.20 .110 2.80 2.150 54.61 5300 7887

Marine & OffshoreProduct Specification J-122IEC–IEEE–ULConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conduct-ingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the cable core. Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEEE 45-1998 & 1993(draft), ICEA S-68-516, UL 1072, J-122 and flame test in IEC60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

BG_MHV8B_172_2_00

ISO9001QSC3497

116

Page 124: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

8K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV-8B CABLESingle Conductor Power (Type N Jacket) 8 kV - Shielded - 133% Level Armored Only

ApplicationBostrig MHV-8B single conductor 8,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c 8 kV Shielded - l33% Level 173

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-8B-5 5 18.6 91/24 .140 3.56 .080 2.03 .950 24.13 650 967MHV-8B-4 4 21.5 105/24 .140 3.56 .080 2.03 .980 24.89 680 1012MHV-8B-2 2 30.7 150/24 .140 3.56 .080 2.03 1.040 26.42 790 1176MHV-8B-1 1 46.0 225/24 .140 3.56 .080 2.03 1.110 28.19 940 1399MHV-8B-1/0 1/0 56.3 275/24 .140 3.56 .080 2.03 1.160 29.46 1050 1563MHV-8B-2/0 2/0 66.5 325/24 .140 3.56 .080 2.03 1.180 29.97 1150 1711MHV-8B-3/0 3/0 92.1 450/24 .140 3.56 .080 2.03 1.280 32.51 1450 2158MHV-8B-4/0 4/0 112.6 550/24 .140 3.56 .080 2.03 1.340 34.04 1600 2381MHV-8B-262 262 133.0 650/24 .140 3.56 .080 2.03 1.410 35.81 1800 2679MHV-8B-313 313 158.6 775/24 .140 3.56 .085 2.16 1.480 37.59 2050 3051MHV-8B-373 373 189.3 925/24 .140 3.56 .085 2.16 1.540 39.12 2300 3423MHV-8B-444 444 225.1 1100/24 .140 3.56 .090 2.29 1.620 41.15 2600 3869MHV-8B-535 535 271.2 1325/24 .140 3.56 .090 2.29 1.710 43.43 2950 4390MHV-8B-646 646 327.5 1600/24 .140 3.56 .110 2.80 1.860 47.24 3500 5209MHV-8B-777 777 393.8 1925/24 .140 3.56 .110 2.80 1.970 50.04 4050 6027MHV-8B-1111 1111 562.8 2750/24 .140 3.56 .110 2.80 2.190 55.63 5350 7962

Marine & OffshoreProduct Specification J-123IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the cable core. Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEEE 45-1998 & 1993 (draft),ICEA S-68-516, UL 1072, J-123 and flame test in IEC 60332-3, catA, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV8B_173_2_00117

Page 125: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

8K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV-8BS CABLESingle Conductor Power (Type N Jacket & Sheath) 8 kV (IEC 3.6/6 kV) Shielded - 100% Level Armored and Sheathed

ApplicationBostrig MHV-8BS single conductor 5,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, thesecables can be supplied without the sheath over the armor.

1/c 8 kV (IEC 3.6/6 kV) Shielded - 100% Level 103

BIW Insulation Jacket/Sheath NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-8BS-6 6 12.5 61/24 .118 3.00 .060/.080 1.53/2.03 .990 25.15 640 952MHV-8BS-5 5 18.6 91/24 .118 3.00 .060/.080 1.53/2.03 1.030 26.16 720 1071MHV-8BS-4 4 21.5 105/24 .118 3.00 .060/.080 1.53/2.03 1.060 26.92 760 1131MHV-8BS-2 2 30.7 150/24 .118 3.00 .080/.080 2.03/2.03 1.160 29.46 920 1369MHV-8BS-1 1 46.0 225/24 .118 3.00 .080/.080 2.03/2.03 1.220 30.99 1100 1637MHV-8BS-l/0 1/0 56.3 275/24 .118 3.00 .080/.080 2.03/2.03 1.270 32.26 1200 1786MHV-8BS-2/0 2/0 66.5 325/24 .118 3.00 .080/.080 2.03/2.03 1.290 32.77 1270 1890MHV-8BS-3/0 3/0 92.1 450/24 .118 3.00 .080/.080 2.03/2.03 1.390 35.31 1550 2307MHV-8BS-4/0 4/0 112.6 550/24 .118 3.00 .080/.080 2.03/2.03 1.440 36.58 1750 2604MHV-8BS-262 262 133.0 650/24 .118 3.00 .080/.080 2.03/2.03 1.490 37.85 1900 2828MHV-8BS-313 313 158.6 775/24 .118 3.00 .080/.080 2.03/2.03 1.580 40.13 2200 3274MHV-8BS-373 373 189.3 925/24 .118 3.00 .085/.080 2.16/2.03 1.650 41.91 2500 3720MHV-8BS-444 444 225.1 1100/24 .118 3.00 .085/.080 2.16/2.03 1.780 45.21 2900 4316MHV-8BS-535 535 271.2 1325/24 .118 3.00 .090/.110 2.29/2.80 1.880 47.75 3300 4911MHV-8BS-646 646 327.5 1600/24 .118 3.00 .110/.110 2.80/2.80 2.030 51.56 3800 5655MHV-8BS-777 777 393.8 1925/24 .118 3.00 .110/.110 2.80/2.80 2.130 54.10 4350 6474MHV-8BS-1111 1111 562.8 2750/24 .118 3.20 .110/.110 2.80/2.80 2.370 60.20 5750 8557

Marine & OffshoreProduct Specification J-122IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

Jacket and SheathBoth the inner jacket applied over the metallic braid shield and outersheath over the armor are flame retardant, heavy duty articNeoprene. Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEC 60502, IEC 60092-354,IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-122 andFlame test in IEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in conformanceto IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Typeapproved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV8_102_103_2_00118

Page 126: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

8K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV-8BS CABLESingle Conductor Power (Type N Jacket & Sheath)8 kV (IEC 6/10 kV) Shielded - 133% LevelArmored and Sheathed

ApplicationBostrig MHV-8BS single conductor 8,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, thesecables can be supplied without the sheath over the armor.

1/c - 8 kV (IEC 6/10 kv) Shielded - 133% Level 105

BIW Insulation Jacket/Sheath NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV-8BS-5 5 18.6 91/24 .140 3.56 .080/.080 2.03/2.03 1.120 28.45 810 1205MHV-8BS-4 4 21.5 105/24 .140 3.56 .080/.080 2.03/2.03 1.050 29.21 860 1280MHV-8BS-2 2 30.7 150/24 .140 3.56 .080/.080 2.03/2.03 1.210 30.73 980 1458MHV-8BS-1 1 46.0 225/24 .140 3.56 .080/.080 2.03/2.03 1.270 32.26 1150 1711MHV-8BS-1/0 1/0 56.3 275/24 .140 3.56 .080/.080 2.03/2.03 1.320 33.53 1250 1860MHV-8BS-2/0 2/0 66.5 325/24 .140 3.56 .080/.080 2.03/2.03 1.340 34.04 1330 1979MHV-8BS-3/0 3/0 92.1 450/24 .140 3.56 .080/.080 2.03/2.03 1.440 36.58 1650 2455MHV-8BS-4/0 4/0 112.6 550/24 .140 3.56 .080/.080 2.03/2.03 1.500 38.10 1820 2708MHV-8BS-262 262 133.0 650/24 .140 3.56 .080/.080 2.03/2.03 1.570 39.88 2030 3021MHV-8BS-313 313 158.6 775/24 .140 3.56 .085/.080 2.16/2.03 1.640 41.66 2300 3423MHV-8BS-373 373 189.3 925/24 .140 3.56 .085/.110 2.16/2.80 1.770 44.96 2650 3944MHV-8BS-444 444 225.1 1100/24 .140 3.56 .090/.110 2.29/2.80 1.850 46.99 3000 4465MHV-8BS-535 535 271.2 1325/24 .140 3.56 .090/.110 2.29/2.80 1.940 49.28 3400 5060MHV-8BS-646 646 327.5 1600/24 .140 3.56 .110/.110. 2.80/2.80 2.080 52.83 3900 5804MHV-8BS-777 777 393.8 1925/24 .140 3.56 .110/.110 2.80/2.80 2.190 55.63 4500 6697MHV-8BS-1111 1111 562.8 2750/24 .140 3.56 .110/.110 2.80/2.80 2.410 61.21 5850 8706

Marine & OffshoreProduct Specification J-123IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

Jacket and SheathBoth the inner jacket applied over the metallic braid shield and outersheath over the annor are flame retardant, heavy duty arctic Neoprene.Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEC 60502, IEC 60092-354,IEEE 45-1998 & 1993 (draft), ICEA 5-68-516, UL 1072, J-123 andFlame test in IEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in conformanceto IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Typeapproved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV8_104_105_2_00119

Page 127: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

15K

V

BOSTRIG MHV3-15 CABLEThree Conductor Power (Type N Jacket)15 kV (IEC 12/20 kV) Shielded - 133% LevelUnarmored

ApplicationBostrig MHV3-15 three conductor 15,000 volt shielded cables are suitable for use in commer-cial marine applications, MODU’s, and platforms where flame retardant cables having excellentphysical and electrical properties are required. The cables have excellent resistance to oils,abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either afully insulated grounding conductor or an un-insulated grounding conductor evenly distributedin the interstices.

3/c - 15 kV (IEC 12/20 kV) Shielded - 133% Level 118

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-15-2 2 30.7 150/24 .220 5.59 .115 2.92 2.330 59.18 2600 3869MHV3-15-1 1 46.0 225/24 .220 5.59 .120 3.05 2.470 62.74 3100 4613MHV3-15-1/0 1/0 56.3 275/24 .220 5.59 .125 3.18 2.590 65.79 3500 5209MHV3-15-2/0 2/0 66.5 325/24 .220 5.59 .130 3.30 2.650 67.31 3750 5581MHV3-15-3/0 3/0 92.1 450/24 .220 5.59 .140 3.56 2.930 74.42 4750 7069MHV3-15-4/0 4/0 112.6 550/24 .220 5.59 .145 3.68 3.050 77.47 5300 7887MHV3-15-262 262 133.0 650/24 .220 5.59 .145 3.68 3.160 80.26 5850 8706MHV3-15-313 313 158.6 775/24 .220 5.59 .155 3.94 3.320 84.33 6600 9822MHV3-15-373 373 189.3 925/24 .220 5.59 .160 4.06 3.470 88.14 7450 11087MHV3-15-444 444 225.1 1100/24 .220 5.59 .165 4.19 3.640 92.46 8450 12575MHV3-15-535 535 271.2 1325/24 .220 5.59 .170 4.32 3.850 97.79 9700 14435MHV3-15-646 646 327.5 1600/24 .220 5.59 .185 4.76 4.140 105.16 11300 16816MHV3-15-777 777 393.8 1925/24 .220 5.59 .190 4.83 4.330 109.98 12950 19271MHV3-15-1111 1111 562.8 2750/24 .220 5.59 .210 5.33 4.850 123.19 17300 25745

Marine & OffshoreProduct Specification J-129IIEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the cable core.Thickness as shown in table below.

TestsMeets applicable test requirements in IEC 60502, IEEE 45-1998 &1993 (draft), ICEA S-68-516, UL 1072, J-129, and flame test inIEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497BG_MHV3-15_118_119_2_00

120

Page 128: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

15K

V

BOSTRIG MHV3-15 CABLEThree Conductor Power (Type N Jacket)15 kV (IEC 8.7/15 kV) Shielded - 100% LevelUnarmored

ApplicationBostrig MHV3-15 three conductor 15,000 volt shielded cables are suitable for use in commercialmarine applications, MODU’s, and platforms where flame retardant cables having excellentphysical and electrical properties are required. The cables have excellent resistance to oils, abra-sion, petrochemical fluids, moisture, and sunlight. When required, these cables can be suppliedwithout the sheath over the armor. Cables are also available with either a fully insulated ground-ing conductor or an un-insulated grounding conductor evenly distributed in the interstices.

3/c 15 kV (IEC 8.7/15 kV) Shielded - 100% Level 116

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-15-2 2 30.7 150/24 .177 4.50 .110 2.80 2.110 53.59 2300 3423MHV3-15-1 1 46.0 225/24 .177 4.50 .115 2.92 2.260 57.40 2790 4152MHV3-15-1/0 1/0 56.3 275/24 .177 4.50 .120 3.05 2.390 60.71 3200 4643MHV3-15-2/0 2/0 66.5 325/24 .177 4.50 .120 3.05 2.420 61.47 3370 5015MHV3-15-3/0 3/0 92.1 450/24 .177 4.50 .130 3.30 2.710 68.83 4300 6399MHV3-15-4/0 4/0 112.6 550/24 .177 4.50 .140 3.56 2.840 72.14 4900 7292MHV3-15-262 262 133.0 650/24 .177 4.50 .140 3.56 2.940 74.68 5400 8036MHV3-15-313 313 158.6 775/24 .177 4.50 .145 3.68 3.100 78.74 6100 9078MHV3-15-373 373 189.3 925/24 .177 4.50 .150 3.81 3.260 82.80 6900 10268MHV3-15-444 444 225.1 1100/24 .177 4.50 .155 3.94 3.420 86.87 7900 11756MHV3-15-535 535 271.2 1325/24 .177 4.50 .165 4.19 3.640 92.46 9100 13542MHV3-15-646 646 327.5 1600/24 .177 4.50 .175 4.45 3.870 98.30 10600 15775MHV3-15-777 777 393.8 1925/24 .177 4.50 .185 4.70 4.120 104.65 12300 18304MHV3-15-1111 1111 562.8 2750/24 .177 4.50 .200 5.08 4.620 117.35 16600 24703

Marine & OffshoreProduct Specification J-128IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the cabled core.Thickness as shown in table below.

TestsMeets applicable test requirements in IEC 60502, IEC 60092-354,IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-128, andflame test in IEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV3-15_116_117_2_00121

Page 129: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

15K

V

BOSTRIG MHV3-15B CABLEThree Conductor Power (Type N Jacket) 15 kV - Shielded - 100% Level Armored Only

ApplicationBostrig MHV3-15B single conductor 15,000 volt shielded cables are suitable for use in com-mercial marine applications, MODU’s, and platforms where flame retardant cables havingexcellent physical and electrical properties are required. The cables have excellent resistance tooils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available witheither a fully insulated grounding conductor or an un-insulated grounding conductor evenlydistributed in the interstices.

3/c 15 kV Shielded - 100% Level 178

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-15B-2 2 30.7 150/24 .177 4.50 .110 2.80 2.170 55.12 2660 3959MHV3-15B-1 1 46.0 225/24 .177 4.50 .115 2.92 2.320 58.93 3200 4762MHV3-15B-l/0 1/0 56.3 275/24 .177 4.50 .120 3.05 2.450 62.23 3550 5283MHV3-15B-2/0 2/0 66.5 325/24 .177 4.50 .120 3.05 2.480 62.99 3800 5655MHV3-15B-3/0 3/0 92.1 450/24 .177 4.50 .130 3.30 2.770 70.36 4800 7143MHV3-15B-4/0 4/0 112.6 550/24 .177 4.50 .140 3.56 2.900 73.66 5400 8036MHV3-15B-262 262 133.0 650/24 .177 4.50 .140 3.56 3.000 76.20 5950 8855MHV3-15B-313 313 158.6 775/24 .177 4.50 .145 3.68 3.160 80.26 6700 9971MHV3-15B-373 373 189.3 925/24 .177 4.50 .150 3.81 3.320 84.33 7550 11236MHV3-15B-444 444 225.1 1100/24 .177 4.50 .155 3.94 3.480 88.39 8550 12724MHV3-15B-535 535 271.2 1325/24 .177 4.50 .165 4.19 3.700 93.98 9800 14584MHV3-15B-646 646 327.5 1600/24 .177 4.50 .175 4.45 3.930 99.82 11300 16816MHV3-15B-777 777 393.8 1925/24 .177 4.50 .185 4.70 4.180 106.17 13100 19495MHV3-15B-1111 1111 562.8 2750/24 .177 4.50 .200 5.08 4.680 118.87 17500 26042

Marine & OffshoreProduct Specification J-128IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the cable core. Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEEE 45-1998 & 1993 (draft),ICEA S-68-516, UL 1072, J-128 and flame test in IEC 60332-3, catA, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV3-15B_178_2_00122

Page 130: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

15K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV3-15B CABLEThree Conductor Power (Type N Jacket) 15 kV - Shielded - 133% Level Armored Only

ApplicationBostrig MHV3-15B three conductor 15,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

3/c 15 kV Shielded - 133% Level 179

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-15B-2 2 30.7 150/24 .220 5.59 .115 2.92 2.390 60.71 3010 4479MHV3-15B-1 1 46.0 225/24 .220 5.59 .120 3.05 2.530 64.26 3550 5283MHV3-15B-1/0 1/0 56.3 275/24 .220 5.59 .125 3.18 2.650 67.31 3950 5878MHV3-15B-2/0 2/0 66.5 325/24 .220 5.59 .130 3.30 2.710 68.83 4250 6325MHV3-15B-3/0 3/0 92.1 450/24 .220 5.59 .140 3.56 2.990 75.95 5250 7813MHV3-15B-4/0 4/0 112.6 550/24 .220 5.59 .145 3.68 3.110 78.99 5850 8706MHV3-15B-262 262 133.0 650/24 .220 5.59 .145 3.68 3.220 81.78 6400 9525MHV3-15B-313 313 158.6 775/24 .220 5.59 .155 3.94 3.380 85.85 7200 10715MHV3-15B-373 373 189.3 925/24 .220 5.59 .160 4.06 3.530 89.66 8100 12054MHV3-15B-444 444 225.1 1100/24 .220 5.59 .165 4.19 3.700 93.98 9100 13542MHV3-15B-535 535 271.2 1325/24 .220 5.59 .170 4.32 3.910 99.31 10400 15477MHV3-15B-646 646 327.5 1600/24 .220 5.59 .185 4.76 4.200 106.68 12100 18007MHV3-15B-777 777 393.8 1925/24 .220 5.59 .190 4.83 4.390 111.51 13800 20536MHV3-15B-1111 1111 562.8 2750/24 .220 5.59 .210 5.33 4.910 124.71 18200 27084

Marine & OffshoreProduct Specification J-129IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the cable core. Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEEE 45-1998 & 1993 (draft),ICEA S-68-516, UL 1072, J-129 and flame test in IEC 60332-3, catA, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV3-15B_179_2_00123

Page 131: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

15K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV3-15BS CABLEThree Conductor Power (Type N Jacket & Sheath)15 kV (IEC 12/20 kV) Shielded - 133% LevelArmored and Sheathed

ApplicationBostrig MHV3-15BS three conductor 15,000 volt shielded cables are suitable for use in com-mercial marine applications, MODU’s, and platforms where flame retardant cables havingexcellent physical and electrical properties are required. The cables have excellent resistance tooils, abrasion, petrochemical fluids, moisture, and sunlight. When required these cables can besupplied without the sheath over the armor. Cables are also available with either a fully insu-lated grounding conductor or an un-insulated grounding conductor evenly distributed in theinterstices.

Marine & OffshoreProduct Specification J-129IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

Jacket and SheathBoth the inner jacket applied over the cabled core and outer sheathover the armor are flame retardant, heavy duty arctic Neoprene.Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEC 60502, IEEE 45-1998 &1993 (draft), ICEA S-68-516, UL 1072, J-129, and flame test inIEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

3/c 15 kV (IEC 12/20 kV) Shielded - 133% Level 119

BIW Insulation Jacket/Sheath NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-15BS-2 2 30.7 150/24 .220 5.59 .115/.110 2.92/2.80 2.600 66.04 3600 5357MHV3-15BS-1 1 46.0 225/24 .220 5.59 .120/.110 3.05/2.80 2.750 69.85 4150 6176MHV3-15BS-1/0 1/0 56.3 275/24 .220 5.59 .125/.140 3.18/3.56 2.930 74.42 4700 6994MHV3-15BS-2/0 2/0 66.5 325/24 .220 5.59 .130/.140 3.30/3.56 2.970 75.44 5000 7441MHV3-15BS-3/0 3/0 92.1 450/24 .220 5.59 .140/.140 3.56/3.56 3.260 82.85 6100 9078MHV3-15BS-4/0 4/0 112.6 550/24 .220 5.59 .145/.140 3.68/3.56 3.380 85.85 6750 10045MHV3-15BS-262 262 133.0 650/24 .220 5.59 .145/.140 3.68/3.56 3.480 88.39 7300 10864MHV3-15BS-313 313 158.6 775/24 .220 5.59 .155/.140 3.94/3.56 3.650 92.71 8150 12129MHV3-15BS-373 373 189.3 925/24 .220 5.59 .160/.140 4.06/3.56 3.810 96.77 9100 13542MHV3-15BS-444 444 225.1 1100/24 .220 5.59 .165/.140 4.19/3.56 3.970 100.84 10200 15180MHV3-15BS-535 535 271.2 1325/24 .220 5.59 .170/.140 4.32/3.56 4.180 106.17 11500 17114MHV3-15BS-646 646 327.5 1600/24 .220 5.59 .185/.140 4.76/3.56 4.470 113.54 13300 19793MHV3-15BS-777 777 393.8 1925/24 .220 5.59 .190/.140 4.83/3.56 4.670 118.62 15000 22322MHV3-15BS-1111 1111 562.8 2750/24 .220 5.59 .210/.140 5.33/3.56 5.190 131.83 19600 29168

ISO9001QSC3497

BG_MHV3-15_118_119_2_00124

Page 132: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

15K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV3-15BS CABLEThree Conductor Power (Type N Jacket & Sheath)15 kV (IEC 8.7/15 kV) Shielded - 100% LevelArmored and Sheathed

ApplicationBostrig MHV3-15BS three conductor 15,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, thesecables can be supplied without the sheath over the armor. Cables are also available with eithera fully insulated grounding conductor or an un-insulated grounding conductor evenly distrib-uted in the interstices.

Marine & OffshoreProduct Specification J-128IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

Jacket and SheathBoth the inner jacket applied over the cabled core and outer sheathover the armor are flame retardant, heavy duty arctic Neoprene.Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEC 60502, IEC 60092-354,IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-128, andflame test in IEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

3/c 15 kV (IEC 8.7/15 kV) Shielded - 100% Level 117

BIW Insulation Jacket/Sheath NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-15BS-2 2 30.7 150/24 .177 4.50 .110/.110 2.80/2.80 2.400 60.96 3150 4688MHV3-15BS-1 1 46.0 225/24 .177 4.50 .115/.110 2.92/2.80 2.540 64.52 3700 5506MHV3-15BS-1/0 1/0 56.3 275/24 .177 4.50 .120/.110 3.05/2.80 2.670 67.82 4100 6102MHV3-15BS-2/0 2/0 66.5 325/24 .177 4.50 .120/.110 3.05/2.80 2.710 68.83 4400 6548MHV3-15BS-3/0 3/0 92.1 450/24 .177 4.50 .130/.140 3.30/2.80 3.050 77.47 5600 8334MHV3-15BS-4/0 4/0 112.6 550/24 .177 4.50 .140/.140 3.56/3.56 3.180 80.77 6200 9226MHV3-15BS-262 262 133.0 650/24 .177 4.50 .140/.140 3.56/3.56 3.290 83.57 6800 10120MHV3-15BS-313 313 158.6 775/24 .177 4.50 .145/.140 3.68/3.56 3.440 87.38 7600 11310MHV3-15BS-373 373 189.3 925/24 .177 4.50 .150/.140 3.81/3.56 3.600 91.44 8500 12649MHV3-15BS-444 444 225.1 1100/24 .177 4.50 .155/.140 3.94/3.56 3.760 95.50 9500 14138MHV3-15BS-535 535 271.2 1325/24 .177 4.50 .165/.140 4.19/3.56 3.980 101.09 10800 16072MHV3-15BS-646 646 327.5 1600/24 .177 4.50 .175/.140 4.45/3.56 4.210 106.93 12400 18453MHV3-15BS-777 777 393.8 1925/24 .177 4.50 .185/.140 4.70/3.56 4.470 113.54 14300 21281MHV3-15BS-1111 1111 562.8 2750/24 .177 4.50 .200/.140 5.08/3.56 4.970 126.24 18700 27829

ISO9001QSC3497

BG_MHV3-15_116_117_2_00125

Page 133: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

5K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV3-5 CABLEThree Conductor Power (Type N Jacket)5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% LevelUnarmored

ApplicationBostrig MHV3-5 three conductor 5,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also avail-able with either a fully insulated grounding conductor or an un-insulated grounding conductorevenly distributed in the interstices.

3/c - 5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level 110

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-5-8 8 7.57 37/24 .090 2.29 .080 2.03 1.300 33.02 850 1265MHV3-5-6 6 12.5 61/24 .090 2.29 .085 2.16 1.430 36.32 1070 1592MHV3-5-5 5 18.6 91/24 .090 2.29 .085 2.16 1.510 38.35 1260 1875MHV3-5-4 4 21.5 105/24 .090 2.29 .090 2.29 1.580 40.13 1380 2054MHV3-5-2 2 30.7 150/24 .090 2.29 .110 2.80 1.750 44.45 1730 2575MHV3-5-1 1 46.0 225/24 .090 2.29 .110 2.80 1.880 47.75 2160 3214MHV3-5-1/0 1/0 56.3 275/24 .090 2.29 .110 2.80 1.990 50.55 2450 3646MHV3-5-2/0 2/0 66.5 325/24 .090 2.29 .110 2.80 2.030 51.56 2700 4018MHV3-5-3/0 3/0 92.1 450/24 .095 2.40 .115 2.92 2.280 57.91 3500 5210MHV3-5-4/0 4/0 112.6 550/24 .095 2.40 .120 3.05 2.400 60.96 4000 5953MHV3-5-262 262 133.0 650/24 .095 2.40 .125 3.18 2.520 64.01 4500 6697MHV3-5-313 313 158.6 775/24 .095 2.40 .130 3.30 2.720 69.09 5300 7887MHV3-5-373 373 189.3 925/24 .095 2.40 .140 3.56 2.880 73.15 6100 9078MHV3-5-444 444 225.1 1100/24 .095 2.40 .145 3.68 3.040 77.22 7000 10417MHV3-5-535 535 271.2 1325/24 .095 2.40 .150 3.81 3.260 82.55 8050 11980MHV3-5-646 646 327.5 1600/24 .103 2.60 .160 4.06 3.520 89.41 9600 14286MHV3-5-777 777 393.8 1925/24 .103 2.60 .170 4.32 3.730 94.74 11200 16667MHV3-5-1111 1111 562.8 2750/24 .110 2.80 .190 4.83 4.320 109.73 15600 23215

Marine & OffshoreProduct Specification J-125IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the cable core.Thickness as shown in table below.

TestsMeets applicable test requirements in IEC 60502, IEEE 45-1998 &1993 (draft), ICEA S-68-516, UL 1072, J-125, and flame test inIEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497BG_MHV3-5_110_111_2_00

126

Page 134: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

5K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV3-5B CABLEThree Conductor Power (Type N Jacket) 5 kV - Shielded - 100% or 133% Level Armored Only

ApplicationBostrig MHV3-5B three conductor 5,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also avail-able with either a fully insulated grounding conductor or an un-insulated grounding conductorevenly distributed in the interstices.

3/c - 5 kV Shielded - 100% or 133% Level 175

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-5B-8 8 7.57 37/24 .090 2.29 .080 2.03 1.360 34.54 1090 1622MHV3-5B-6 6 12.5 61/24 .090 2.29 .085 2.16 1.490 37.85 1330 1980MHV3-5B-5 5 18.6 91/24 .090 2.29 .085 2.16 1.570 39.88 1530 2276MHV3-5B-4 4 21.5 105/24 .090 2.29 .090 2.29 1.640 41.66 1670 2485MHV3-5B-2 2 30.7 150/24 .090 2.29 .110 2.80 1.810 45.97 2030 3021MHV3-5B-1 1 46.0 225/24 .090 2.29 .110 2.80 1.940 49.28 2500 3721MHV3-5B-1/0 1/0 56.3 275/24 .090 2.29 .110 2.80 2.050 52.07 2800 4167MHV3-5B-2/0 2/0 66.5 325/24 .090 2.29 .110 2.80 2.080 52.83 3050 4539MHV3-5B-3/0 3/0 92.1 450/24 .095 2.40 .115 2.92 2.340 59.44 3900 5804MHV3-5B-4/0 4/0 112.6 550/24 .095 2.40 .120 3.06 2.460 62.48 4450 6622MHV3-5B-262 262 133.0 650/24 .095 2.40 .125 3.18 2.580 65.53 5000 7441MHV3-5B-313 313 158.6 775/24 .095 2.40 .130 3.30 2.780 70.61 5800 8631MHV3-5B-373 373 189.3 925/24 .095 2.40 .140 3.56 2.940 74.68 6600 9822MHV3-5B-444 444 225.1 1100/24 .095 2.40 .145 3.68 3.100 78.74 7550 11236MHV3-5B-535 535 271.2 1325/24 .095 2.40 .150 3.81 3.320 84.33 8750 13021MHV3-5B-646 646 327.5 1600/24 .103 2.60 .160 4.06 3.580 90.93 10300 15328MHV3-5B-777 777 393.8 1925/24 .103 2.60 .170 4.32 3.790 96.27 11900 17709MHV3-5B-1111 1111 562.8 2750/24 .110 2.80 .190 4.83 4.380 111.25 16400 24406

Marine & OffshoreProduct Specification J-125IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the metallic braid shield.Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEEE 45-1998 & 1993 (draft),ICEA S-68-5I6, UL 1072, J-125 and flame test in IEC 60332-3, catA, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV3-5B_175_2_00127

Page 135: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

5K

V

BOSTRIG MHV3-5BS CABLEThree Conductor Power (Type N Jacket & Sheath) 5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% LevelArmored and Sheathed

ApplicationBostrig MHV3-5BS three conductor 5,000 volt shielded cables are suitable for use incommercial marinc applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, thesecables can be supplied without the sheath over the armor. Cables are also available with either afully insulated grounding conductor or an un-insulated grounding conductor evenly distributed inthe interstices.

Marine & OffshoreProduct Specification J-125IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

Jacket and SheathBoth the inner jacket applied over the cable core and outer sheathover the armor are flame retardant, heavy duty arctic Neoprene.Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEC 60502, IEEE 45-1998 &1993 (draft), ICEAS-68-516, UL 1072, J-125, and flame test inIEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

3/c - 5 kV (IEC 1.8/3 kV) Shielded - l00% or 133% Level 111

BIW Insulation Jacket/Sheath NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-5BS-8 8 7.57 37/24 .090 2.29 .080/.080 2.03/2.03 1.520 38.61 1350 2009MHV3-5BS-6 6 12.5 61/24 .090 2.29 .085/.080 2.16/2.03 1.650 41.91 1600 2381MHV3-5BS-5 5 18.6 91/24 .090 2.29 .085/.110 2.16/2.80 1.800 45.72 1900 2828MHV3-5BS-4 4 21.5 105/24 .090 2.29 .090/.110 2.29/2.80 1.870 47.54 2050 3051MHV3-5BS-2 2 30.7 150/24 .090 2.29 .110/.110 2.80/2.80 2.030 51.56 2450 3646MHV3-5BS-l 1 46.0 225/24 .090 2.29 .110/.110 2.80/2.80 2.160 54.86 2950 4390MHV3-5BS-l/0 1/0 56.3 275/24 .090 2.29 .110/.110 2.80/2.80 2.280 57.91 3300 4911MHV3-5BS-2/0 2/0 66.5 325/24 .090 2.29 .110/.110 2.80/2.80 2.320 58.93 3550 5283MHV3-5BS-3/0 3/0 92.1 450/24 .095 2.40 .115/.110 2.92/2.80 2.560 65.02 4450 6622MHV3-5BS-4/0 4/0 112.6 550/24 .095 2.40 .120/.110 3.05/2.80 2.680 68.07 5000 7441MHV3-5BS-262 262 133.0 650/24 .095 2.40 .125/.110 3.18/2.80 2.860 72.64 5700 8483MHV3-5BS-313 313 158.6 775/24 .095 2.40 .130/.140 3.30/3.56 3.060 77.72 6600 9822MHV3-5BS-373 373 189.3 925/24 .095 2.40 .140/.140 3.56/3.56 3.220 81.79 7450 11087MHV3-5BS-444 444 225.1 1100/24 .095 2.40 .145/.140 3.68/3.56 3.380 85.85 8450 12575MHV3-5BS-535 535 271.2 1325/24 .095 2.40 .150/.140 3.81/3.56 3.590 91.19 9700 14435MHV3-5BS-646 646 327.5 1600/24 .103 2.60 .160/.140 4.06/3.56 3.860 98.04 11300 16816MHV3-5BS-777 777 393.8 1925/24 .103 2.60 .170/.140 4.32/3.56 4.070 103.38 13000 19346MHV3-5BS-1111 1111 562.8 2750/24 .110 2.80 .190/.140 4.83/3.56 4.660 118.36 17600 26192

ISO9001QSC3497

BG_MHV3-5_110_111_2_00128

Page 136: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

8K

V

BOSTRIG MHV3-8 CABLEThree Conductor Power (Type N Jacket)8 kV (IEC 3.6/6 kV) Shielded - 100% LevelUnarmored

ApplicationBostrig MHV3-8 three conductor 8,000 volt shielded cables are suitable for use in commercialmarine applications, MODU’s, and platforms where flame retardant cables having excellentphysical and electrical properties are required. The cables have excellent resistance to oils,abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either afully insulated grounding conductor or an un-insulated grounding conductor evenly distributedin the interstices.

3/c - 8 kV (IEC 3.6/6 kV) Shielded - 100% Level 112

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-8-6 6 12.5 61/24 .118 3.00 .090 2.29 1.570 39.88 1230 1830MHV3-8-5 5 18.6 91/24 .118 3.00 .090 2.29 1.650 41.91 1420 2113MHV3-8-4 4 21.5 105/24 .118 3.00 .095 2.40 1.710 43.43 1560 2322MHV3-8-2 2 30.7 150/24 .118 3.00 .110 2.80 1.870 47.50 1890 2813MHV3-8-1 1 46.0 225/24 .118 3.00 .110 2.80 2.000 50.80 2340 3482MHV3-8-1/0 1/0 56.3 275/24 .118 3.00 .110 2.80 2.110 53.59 2640 3929MHV3-8-2/0 2/0 66.5 325/24 .118 3.00 .110 2.80 2.150 54.61 3900 4316MHV3-8-3/0 3/0 92.1 450/24 .118 3.00 .120 3.05 2.400 60.96 3700 5506MHV3-8-4/0 4/0 112.6 550/24 .118 3.00 .125 3.18 2.510 63.75 4200 6250MHV3-8-262 262 133.0 650/24 .118 3.00 .130 3.30 2.630 66.80 4700 6994MHV3-8-313 313 158.6 775/24 .118 3.00 .140 3.56 2.830 71.88 5550 8259MHV3-8-373 373 189.3 925/24 .118 3.00 .145 3.56 2.990 75.95 6300 9375MHV3-8-444 444 225.1 1100/24 .118 3.00 .145 3.68 3.150 80.01 7250 10789MHV3-8-535 535 271.2 1325/24 .118 3.00 .155 3.94 3.360 85.34 8450 12575MHV3-8-646 646 327.5 1600/24 .118 3.00 .165 4.19 3.590 91.19 9850 14658MHV3-8-777 777 393.8 1925/24 .118 3.00 .170 4.32 3.800 96.52 11400 16965MHV3-8-1111 1111 562.8 2750/24 .126 3.20 .195 4.95 4.400 111.76 15850 23587

Marine & OffshoreProduct Specification J-126IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the cable core. Thickness as shown in table below.

TestsMeets applicable test requirements in IEC 60502, IEC 60092-354,IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-126, andflame test in IEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497BG_MHV3-8_112_113_2_00

129

Page 137: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

8K

V

BOSTRIG MHV3-8 CABLEThree Conductor Power (Type N Jacket)8 kV (IEC 6/10 kV) Shielded - 133% LevelUnarmored

ApplicationBostrig MHV3-8 three conductor 8,000 volt shielded cables are suitable for use in commercialmarine applications, MODU’s, and platforms where flame retardant cables having excellentphysical and electrical properties are required. The cables have excellent resistance to oils,abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either afully insulated grounding conductor or an un-insulated grounding conductor evenly distributedin the interstices.

3/c - 8 kV (IEC 6/10 kV) Shielded - 133% Level 114

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-8-5 5 18.6 91/24 .140 3.56 .110 2.80 1.780 45.21 1610 2396MHV3-8-4 4 21.5 105/24 .140 3.56 .110 2.80 1.840 46.74 1730 2575MHV3-8-2 2 30.7 150/24 .140 3.56 .110 2.80 1.960 49.78 2030 3021MHV3-8-1 1 46.0 225/24 .140 3.56 .110 2.80 2.100 53.34 2470 3676MHV3-8-1/0 1/0 56.3 275/24 .140 3.56 .115 2.92 2.210 56.13 2790 4152MHV3-8-2/0 2/0 66.5 325/24 .140 3.56 .115 2.92 2.250 57.15 3040 4524MHV3-8-3/0 3/0 92.1 450/24 .140 3.56 .125 3.18 2.500 63.50 3870 5759MHV3-8-4/0 4/0 112.6 550/24 .140 3.56 .125 3.18 2.610 66.29 4380 6518MHV3-8-262 262 133.0 650/24 .140 3.56 .135 3.43 2.780 70.61 5000 7440MHV3-8-313 313 158.6 775/24 .140 3.56 .140 3.56 2.930 74.42 5750 8557MHV3-8-373 373 189.3 925/24 .140 3.56 .145 3.68 3.090 78.49 6550 9748MHV3-8-444 444 225.1 1100/24 .140 3.56 .150 3.81 3.250 82.55 7500 11161MHV3-8-535 535 271.2 1325/24 .140 3.56 .160 4.06 3.470 88.14 8700 12947MHV3-8-646 646 327.5 1600/24 .140 3.56 .165 4.19 3.690 93.73 10100 15030MHV3-8-777 777 393.8 1925/24 .140 3.56 .175 4.45 3.950 100.33 11800 17560MHV3-8-1111 1111 562.8 2750/24 .140 3.56 .195 4.95 4.460 113.28 16100 23959

Marine & OffshoreProduct Specification J-127IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketAjacket of flame retardant, heavy duty arctic Neoprene is appliedover the cable core.Thickness as shown in table below.

TestsMeets applicable test requirements in IEC 60502, IEC 60092-354,IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-127, andflame test in IEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in conformanceto IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Typeapproved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV3-8_114_115_2_00130

Page 138: Prysmian Draka - Marine & Offshore LV HV Cables

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

TY

PE

N J

AC

KE

T –

8K

V

BOSTRIG MHV3-8B CABLEThree Conductor Power (Type N Jacket) 8 kV - Shielded - 100% Level Armored Only

ApplicationBostrig MHV3-8B three conductor 8,000 volt shielded cables are suitable for use in commer-cial marine applications, MODU’s, and platforms where flame retardant cables having excel-lent physical and electrical properties are required. The cables have excellent resistance to oils,abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either afully insulated grounding conductor or an un-insulated grounding conductor evenly distributedin the interstices.

3/c - 8 kV Shielded - 100% Level 176

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-8B-6 6 12.5 61/24 .118 3.00 .090 2.29 1.630 41.40 1510 2247MHV3-8B-5 5 18.6 91/24 .118 3.00 .090 2.29 1.710 43.43 1720 2560MHV3-8B-4 4 21.5 105/24 .118 3.00 .095 2.40 1.770 44.93 1870 2783MHV3-8B-2 2 30.7 150/24 .118 3.00 .110 2.80 1.930 49.02 2250 3348MHV3-8B-1 1 46.0 225/24 .118 3.00 .110 2.80 2.060 52.32 2700 4018MHV3-8B-1/0 1/0 56.3 275/24 .118 3.00 .110 2.80 2.170 55.12 3050 4539MHV3-8B-2/0 2/0 66.5 325/24 .118 3.00 .110 2.80 2.210 56.13 3300 4911MHV3-8B-3/0 3/0 92.1 450/24 .118 3.00 .120 3.05 2.460 62.48 4150 6176MHV3-8B-4/0 4/0 112.6 550/24 .118 3.00 .125 3.18 2.570 65.28 4700 6994MHV3-8B-262 262 133.0 650/24 .118 3.00 .130 3.30 2.690 68.32 5200 7738MHV3-8B-313 313 158.6 775/24 .118 3.00 .140 3.56 2.890 73.41 6050 9003MHV3-8B-373 373 189.3 925/24 .118 3.00 .140 3.56 3.050 77.47 6850 10194MHV3-8B-444 444 225.1 1100/24 .118 3.00 .145 3.68 3.210 81.53 7800 11607MHV3-8B-535 535 271.2 1325/24 .118 3.00 .155 3.94 3.420 86.87 9050 13468MHV3-8B-646 646 327.5 1600/24 .118 3.00 .165 4.19 3.650 92.71 10500 15626MHV3-8B-777 777 393.8 1925/24 .118 3.00 .170 4.32 3.860 98.04 12100 18007MHV3-8B-1111 1111 562.8 2750/24 .126 3.20 .195 4.95 4.460 113.28 16700 24852

Marine & OffshoreProduct Specification J-126IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the cable core.Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEEE 45-1998 & 1993 (draft),ICEA S-68-516, UL 1072, J-126 and flame test in IEC 60332-3, cat A,A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in conformanceto IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Typeapproved by DNV, ABS and LRS.

DRAKA-USA

ISO9001QSC3497

BG_MHV3-8B_176_2_00131

Page 139: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

8K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV3-8B CABLEThree Conductor Power (Type N Jacket) 8 kV - Shielded - 133% Level Armored Only

ApplicationBostrig MHV3-8B single conductor 8,000 volt shielded cables are suitable for use incommercial marine applications, MODU’s, and platforms where flame retardant cableshaving excellent physical and electrical properties are required. The cables have excellentresistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also avail-able with either a fully insulated grounding conductor or an un-insulated grounding conductorevenly distributed in the interstices.

3/c 8 kV Shielded - 133% Level 177

BIW Insulation Jacket NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-8B-5 5 18.6 91/24 .140 3.56 .110 2.80 1.840 46.74 1930 2872MHV3-8B-4 4 21.5 105/24 .140 3.56 .110 2.80 1.900 48.26 2060 3066MHV3-8B-2 2 30.7 150/24 .140 3.56 .110 2.80 2.020 51.31 2380 3542MHV3-8B-1 1 46.0 225/24 .140 3.56 .110 2.80 2.160 54.87 2850 4241MHV3-8B-1/0 1/0 56.3 275/24 .140 3.56 .115 2.92 2.270 57.66 3200 4762MHV3-8B-2/0 2/0 66.5 325/24 .140 3.56 .115 2.92 2.310 58.68 3500 5209MHV3-8B-3/0 3/0 92.1 450/24 .140 3.56 .125 3.18 2.560 65.03 4350 6473MHV3-8B-4/0 4/0 112.6 550/24 .140 3.56 .125 3.18 2.670 67.82 4900 7292MHV3-8B-262 262 133.0 650/24 .140 3.56 .135 3.43 2.840 82.14 5550 8259MHV3-8B-313 313 158.6 775/24 .140 3.56 .140 3.56 2.990 75.95 6300 9375MHV3-8B-373 373 189.3 925/24 .140 3.56 .145 3.68 3.150 80.01 7100 10566MHV3-8B-444 444 225.1 1100/24 .140 3.56 .150 3.81 3.310 84.07 8100 12054MHV3-8B-535 535 271.2 1325/24 .140 3.56 .160 4.06 3.530 89.66 9350 13914MHV3-8B-646 646 327.5 1600/24 .140 3.56 .165 4.19 3.750 95.25 10800 16072MHV3-8B-777 777 393.8 1925/24 .140 3.56 .175 4.45 4.010 101.85 12600 18751MHV3-8B-1111 1111 562.8 2750/24 .140 3.56 .195 4.95 4.520 114.81 16900 25150

Marine & OffshoreProduct Specification J-121IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

JacketA jacket of flame retardant, heavy duty arctic Neoprene is appliedover the cable core. Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEEE 45-1998 & 1993 (draft),ICEA S-68-516, UL 1072, J-127 and flame test in IEC 60332-3, catA, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

ISO9001QSC3497

BG_MHV3-8B_177_2_00132

Page 140: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

8K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV3-8BS CABLEThree Conductor Power (Type N Jacket & Sheath)8 kV (IEC 3.6/6 kV) Shielded - 100% LevelArmored and Sheathed

ApplicationBostrig MHV-8BS three conductor 8,000 volt shielded cables are suitable for use in commer-cial marine applications, MODU’s, and platforms where flame retardant cables having excel-lent physical and electrical properties are required. The cables have excellent resistance to oils,abrasion, petrochemical fluids, moisture, and sunlight. When required, these cables can besupplied without the sheath over the armor. Cables are also available with either a fully insu-lated grounding conductor or an un-insulated grounding conductor evenly distributed in theinterstices.

Marine & OffshoreProduct Specification J-126IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

Jacket and SheathBoth the inner jacket applied over the cabled core and outer sheathover the armor are flame retardant, heavy duty arctic Neoprene.Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEC 60502, IEC 60092-354,IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-126, andflame test in IEC 60332-3, cat A, A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001.Type approved by DNV, ABS and LRS.

3/c - 8 kV (IEC 3.6/6 kV) Shielded - 100% Level 113

BIW Insulation Jacket/Sheath NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-8BS-6 6 12.5 61/24 .118 3.00 .090/.110 2.29/2.80 1.840 46.74 1900 2828MHV3-8BS-5 5 18.6 91/24 .118 3.00 .090/.110 2.29/2.80 1.920 48.77 2100 3125MHV3-8BS-4 4 21.5 105/24 .118 3.00 .095/.110 2.40/2.80 1.990 50.55 2280 3393MHV3-8BS-2 2 30.7 150/24 .118 3.00 .110/.110 2.80/2.80 2.140 54.36 2680 3988MHV3-8BS-1 1 46.0 225/24 .118 3.00 .110/.110 2.80/2.80 2.280 57.91 3180 4732MHV3-8BS-1/0 1/0 56.3 275/24 .118 3.00 .110/.110 2.80/2.80 2.400 60.96 3520 5238MHV3-8BS-2/0 2/0 66.5 325/24 .118 3.00 .110/.110 2.80/2.80 2.430 61.72 3800 5655MHV3-8BS-3/0 3/0 92.1 450/24 .118 3.00 .120/.110 3.05/2.80 2.670 67.82 4700 6994MHV3-8BS-4/0 4/0 112.6 550/24 .118 3.00 .125/.140 3.18/3.56 2.850 72.39 5400 8036MHV3-8BS-262 262 133.0 650/24 .118 3.00 .130/.140 3.30/3.56 2.970 75.44 6000 8929MHV3-8BS-313 313 158.6 775/24 .118 3.00 .140/.140 3.56/3.56 3.170 80.52 6900 10268MHV3-8BS-373 373 189.3 925/24 .118 3.00 .140/.140 3.56/3.56 3.320 84.33 7700 11459MHV3-8BS-444 444 225.1 1100/24 .118 3.00 .145/.140 3.68/3.56 3.480 88.39 8700 12947MHV3-8BS-535 535 271.2 1325/24 .118 3.00 .155/.140 3.94/3.56 3.700 93.98 10000 14881MHV3-8BS-646 646 327.5 1600/24 .118 3.00 .165/.140 4.19/3.56 3.940 100.08 11500 17114MHV3-8BS-777 777 393.8 1925/24 .118 3.00 .170/.140 4.32/3.56 4.140 105.16 13200 19644MHV3-8BS-1111 1111 562.8 2750/24 .126 3.20 .195/.140 4.95/3.56 4.740 120.40 17900 26638

ISO9001QSC3497

BG_MHV3-8_112_113_2_00133

Page 141: Prysmian Draka - Marine & Offshore LV HV Cables

TY

PE

N J

AC

KE

T –

8K

V

1610 Greens Road, Suite 200, Houston, TX 77032Tel: 281.209.1070 • Toll Free: 888.354.2225 24 hour: 281.851.1802 • Fax: 281.209.3857

www.drakausa.com

BOSTRIG MHV3-8BS CABLEThree Conductor Power (Type N Jacket & Sheath)8 kV (IEC 6/10 kV) Shielded - 133% LevelArmored and Sheathed

ApplicationBostrig MHV-8BS three conductor 8,000 volt shielded cables are suitable for use in commer-cial marine applications, MODU’s, and platforms where flame retardant cables having excel-lent physical and electrical properties are required. The cables have excellent resistance to oils,abrasion, petrochemical fluids, moisture, and sunlight. When required, these cables can be sup-plied without the sheath over the armor. Cables are also available with either a fully insulatedgrounding conductor or an un-insulated grounding conductor evenly distributed in the inter-stices.

Marine & OffshoreProduct Specification J-127IEC–IEEE–UL

ConductorSoft annealed tinned copper.Stranding as shown in table below.

Conductor ShieldSemi-conducting tape with extruded thermosetting semi-conductingEPR.

InsulationExtruded thermosetting EPR, 90°C-Type E.Thickness as shown in table below.

Insulation ShieldExtruded thermosetting semi-conducting XLPO.

Metallic Braid ShieldTinned copper braided shield, 85% minimum coverage.

Jacket and SheathBoth the inner jacket applied over the cabled core and outer sheathover the armor are flame retardant, heavy duty arctic Neoprene.Thickness as shown in table below.

ArmorBraided Bronze.

TestsMeets applicable test requirements in IEC 60502, IEC 60092-354,IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-127, andflame test in IEC 60332-3, cat A/F.

RatingListed by a Nationally Recognized Testing Lab (ETL) in confor-mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type approved by DNV, ABS and LRS.

3/c - 8 kV (IEC 6/10 kV) Shielded - 133% Level 115

BIW Insulation Jacket/Sheath NominalCable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight

AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km

MHV3-8BS-5 5 18.6 91/24 .140 3.56 .110/.110 2.80/2.80 2.060 52.32 2350 3497MHV3-8BS-4 4 21.5 105/24 .140 3.56 .110/.110 2.80/2.80 2.120 5.85 2510 3735MHV3-8BS-2 2 30.7 150/24 .140 3.56 .110/.110 2.80/2. 80 2.240 56.90 2860 4256MHV3-8BS-1 1 46.0 225/24 .140 3.56 .110/.110 2.80/2.80 2.380 60.45 3350 4985MHV3-8BS-1/0 1/0 56.3 275/24 .140 3.56 .115/.110 2.92/2.80 2.500 63.50 3730 5550MHV3-8BS-2/0 2/0 66.5 325/24 .140 3.56 .115/.110 2.92/2.80 2.540 64.52 4000 5953MHV3-8BS-3/0 3/0 92.1 450/24 .140 3.56 .125/.140 3.18/3.56 2.840 72.14 5100 7590MHV3-8BS-4/0 4/0 112.6 550/24 .140 3.56 .125/.140 3.18/3.56 2.950 74.93 5650 8408MHV3-8BS-262 262 133.0 650/24 .140 3.56 .135/.140 3.43/3.56 3.100 78.99 6350 9450MHV3-8BS-313 313 158.6 775/24 .140 3.56 .140/.140 3.56/3.56 3.270 83.06 7150 10640MHV3-8BS-373 373 189.3 925/24 .140 3.56 .145/.140 3.68/3.56 3.440 87.38 8000 11905MHV3-8BS-444 444 225.1 1100/24 .140 3.56 .150/.140 3.81/3.56 3.600 91.44 9000 13393MHV3-8BS-535 535 271.2 1325/24 .140 3.56 .160/.140 4.06/3.56 3.810 96.77 10350 15402MHV3-8BS-646 646 327.5 1600/24 .140 3.56 .165/.140 4.19/3.56 4.030 102.36 11800 17560MHV3-8BS-777 777 393.8 1925/24 .140 3.56 .175/.140 4.45/356 4.280 108.71 13700 20388MHV3-8BS-1111 1111 562.8 2750/24 .140 3.56 .195/.140 4.95/3.56 4.800 121.92 18200 27084

ISO9001QSC3497BG_MHV3-8_114_115_2_00134

Page 142: Prysmian Draka - Marine & Offshore LV HV Cables

www.DrakaMOG.com

S611T MARINE FIBER OPTIC CABLES

DUSA_MOG53_0807Subject to change without prior notice

Bostrig Type P0807

Page 53 of 62

Tight buffer construction2 to 48 fibers /singlemode or multimode /LSZH

Construction

1. Central Strength Member Dielectric material (epoxy fiberglass rod).2. Fiber Multimode or singlemode fibers with an easily-strippable 900µm tight buffering colored

per TIA/EIA 598.3. Subunit Strength Member Aramid yarn4. Subunit Jacket ChromaTek-L™ Halex low smoke zero halogen polyolefin.5. Sheath ChromaTek-L™ Halex low smoke zero halogen polyolefin.

Applications

The Drake S611T series of Marine and Offshore fiber optic cables is designed especially for the harsh environments ofcommercial marine vessels, oil platforms and other similar applications.

Draka S611T low smoke/zero halogen, flame retardant cables offer the versatility and ease of use of our other offshorecables in a construction suited for marine applications. They are compliant with the latest IEC requirements.

S611T cables meet the requirements of IEC 60793-1 and IEC 60793-2 specifications, are encapsulated in all dielectric,tight buffered construction, individuall reinforced with aramid yarns and jacketed (breakout style). The breakout components are cabled around a central member providing additonal tensile strength to the entire construction. The thermoplastic low smoke/zero halogen jacketing system offers good resistance to chemicals, fluids, fungus, andabrasion.

This product is readily available in an armored version.

Features

• Low smoke/zero halogen construction meets appropriate IEEE and IEC standardsfor fire, smoke, and toxicity

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Gigabit Ethernet 802.3Z compliant

RatingsMeets IEC 60794-1-1, 60794-1-2 and 60794-2.Det Norske Veritas Type Approval Certificate E-7154.American Bureau of Shipping Approval Certificate 04-HS440499B/2-PDA.Lloyds Registry of Shipping Approval Certificate 00/00157E2.Flame retardant per IEC 60332-3, CAT. A CAT A/F and IEEE 1202Smoke density requirements of IEC 61034-1 and IEC 61034-2Acid gas generation requirements of IEC 60754-1 and IEC 60754-2Toxicity requirements of NES 713Meets the performance requirements of IEEE 802.3z (Gigabit Ethernet)

51 2 3 4

Bostrig Type P bk0108.qxd 1/26/08 2:53 PM Page 53

135

Page 143: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG54_0807

INSTALLATION OPERATING ApproximateDRAKA USA Number Pull Strength Bend Radius Tension Bend Radius Cable O.D. Cable WeightPart Number of Fibers Newtons (lbs) cm (in) Newtons (lbs) cm (in) mm (in) Kg/km (Lbs/mft)

S611T-02R-xxy 2 600 (135) 12.8 (5.0) 200 (45) 6.4 (2.5) 6.4 (.252) 45 (30)

S611T-04-xxy 4 600 (135) 14.6 (5.8 200 (45) 7.3 (2.9) 7.3 (.287) 51 (35)

S611T-06-xxy 6 600 (135) 17.0 (6.8) 200 (45) 8.5 (3.4) 8.5 (.335) 71 (48)

S611T-08-xxy 8 600 (135) 19.4 (7.6) 200 (45) 9.7 (3.8) 9.7 (.381) 93 (63)

S611T-10-xxy 10 600 (135) 22.0 (8.4) 200 (45) 11.0 (4.3) 11.0 (.431) 119 (80)

S611T-12-xxy 12 600 (135) 24.4 (9.6) 200 (45) 12.2 (4.8) 12.2 (.481) 149 (100)

S611T-16-xxy 16 2700 (600) 25.7 (10.2) 600 (135) 12.8 (5.1) 12.8 (.507) 150 (101)

S611T-18-xxy 18 2700 (600) 25.7 (10.2) 600 (135) 12.8 (5.1) 12.8 (.507) 148 (100)

S611T-24-xxy 24 2700 (600) 29.6 (11.6) 600 (135) 14.8 (5.8) 14.8 (.581) 356 (238)

S611T-36-xxy 36 2700 (600) 34.0 (13.4) 600 (135) 17.0 (6.7) 17.0 (.670) 484 (325)

S611T-48-xxy 48 2700 (600) 46.0 (18.1) 600 (135) 23.1 (9.1) 23.0 (.905) 600 (403)

Replace the xxy with the Fiber Designation in the fiber performance table below.NOTE: Fibers are not suitable for F07 crimp and cleave connector.Information is subject to change without notice. Consult factory for a variety of alternate constructions for specific applications.

FIBER PERFORMANCE62.5µm MULTIMODE 200µm MULTIMODE

Fiber Designation 62X 50H 200S 010X

Applicable Specification IEC 60793-2 Type A1b ITU G.651 & IEC 60793-2 Type A1a ITU G.651 & IEC 60793-2 Type A1a ITU G.652 Table C & D Requirements& IEC 60793-2 Type B1.1

Fiber Type Graded Index Graded Index Step Index Matched Clad

Core Diameter 62.5µm ± 2.5µm 50µm ± 2.5µm 200µm ± 5µm 8.3µm Nominal

Cladding Diameter 125µm ± 1µm 125µm ± 1µm 230µm ± 10µm 125µm ± 1µm

Coating Diameter 242µm ± 7µm 242µm ± 7µm 500µm ± 30µm 242µm ± 7µm

Buffer Diameter 900µm ± 50µm 50µm ± 2.5µm 900µm ± 50µm 900µm ± 50µm

Numerical Aperture 0.275 ± 0.015 0.200 ± 0.015 .037 Nominal (2m 5% intensity) N/A

Mode Field Diameter N/A N/A N/A 9.1µm ± 0.4µm

Attenuation 3.5 dB/Km @ 850nm 3.5 dB/Km @ 850nm 12.0 dB/Km @ 820nm 0.70 dB/Km @ 1310nm1.0 dB/Km @ 1300nm 1.0 dB/Km @ 1300nm 0.70 dB/Km @ 1550nm

Bandwidth ≥200 MHz/Km @ 850nm ≥500 MHz/Km @ 850nm ≥20 MHz/Km @ 820nm N/A≥500 MHz/Km @ 1300nm ≥500 MHz/Km @ 1300nm N/A

Dispersion N/A N/A N/A 3.0 ps/nm-Km @1285-1330nmN/A N/A N/A 18 ps/nm-Km @ 1550nm

Proof Test 100,000 psi 100,000 psi 100,000 psi 100,000 psi

CABLE PROPERTIESCrush (IEC 60794-1-E3) 3000 N/ 10 cmImpact (IEC 60794-1-E4) 20 impacts, 5JTorsion (IEC 60794-1-E7) + 1 turn / 2 m, 100 cyclesCable Bend (IEC 60794-1-E11) <0.1 dB/ + 6 turns

TEMPERATURE RANGEOperation -20ºC to +80ºCInstallation -10ºC to +60ºCStorage -40ºC to +80ºC

FIRE, SMOKE, AND TOXICITY CLASSIFICATIONSFlame retardant IEC 60332-3, CAT.A CAT A/F and IEEE 1202Smoke density IEC 61034-1 and IEC 61034-2Acid gas penetration IEC 60754-1 and IEC 60754-2

Toxicity NES 713www.DrakaMOG.com

Subject to change without prior notice

Bostrig Type P0807

Page 54 of 62

S611T MARINE FIBER OPTIC CABLES

tight buffer construction2 to 48 fibers / singlemode or multimode / LSZH

≥≥

≥≥

≥≥≥

≥≥

Bostrig Type P bk0108.qxd 1/26/08 2:53 PM Page 54

50 µm MULTIMODE 8.3µm SINGLEMODE

136

Page 144: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG55_0807

www.DrakaMOG.com

S670T ARMORED AND SHEATHED MARINE FIBER OPTIC CABLES

Subject to change without prior notice

Bostrig Type P0807

Page 55 of 62

Tight buffer construction2 to 48 fibers /singlemode or multimode /LSZH / Armored & Sheathed

Construction

1. Central Strength Member Dielectric material (epoxy fiberglass rod).2. Fiber Multimode or singlemode fibers with an easily-strippable 900µm tight buffering colored

per TIA/EIA 598.3. Subunit Strength Member Aramid yarn4. Subunit Jacket ChromaTek-L™ Halex low smoke zero halogen polyolefin.5. Jacket ChromaTek-L™ Halex low smoke zero halogen polyolefin.6. Armor Braided bronze in accordance with IEEE 1580 (2001).7. Sheath ChromaTek-L™ Halex low smoke zero halogen polyolefin.

Applications

The Drake S670T series of Marine and Offshore fiber optic cables is designed especially for the harsh environments ofcommercial marine vessels, oil platforms and other similar applications.

Draka S670T low smoke/zero halogen, flame retardant cables offer the versatility and ease of use of our other offshorecables in a construction suited for marine applications. They are compliant with the latest IEC requirements.

S670T cables meet the requirements of IEC 60793-1 and IEC 60793-2 specifications, are encapsulated in all dielectric,tight buffered construction, individuall reinforced with aramid yarns and jacketed (breakout style). The breakout components are cabled around a central member providing additonal tensile strength to the entire construction. The thermoplastic low smoke/zero halogen jacketing system offers good resistance to chemicals, fluids, fungus, andabrasion.

This product is readily available in a non-armored version.

Features

• Low smoke/zero halogen construction meets appropriate IEEE and IEC standardsfor fire, smoke, and toxicity

• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact• Gigabit Ethernet 802.3Z compliant

RatingsMeets IEC 60794-1-1, 60794-1-2 and 60794-2.Det Norske Veritas Type Approval Certificate E-7155.American Bureau of Shipping Approval Certificate 04-HS440499B/2-PDA.Lloyds Registry of Shipping Approval Certificate 00/00157E2.Flame retardant per IEC 60332-3, CAT. A CAT A/F and IEEE 1202Smoke density requirements of IEC 61034-1 and IEC 61034-2Acid gas generation requirements of IEC 60754-1 and IEC 60754-2Toxicity requirements of NES 713Meets the performance requirements of IEEE 802.3z (Gigabit Ethernet)

51 2 3 4 6 7

Bostrig Type P bk0108.qxd 1/26/08 2:53 PM Page 55

137

Page 145: Prysmian Draka - Marine & Offshore LV HV Cables

DUSA_MOG56_0807

S670T ARMORED AND SHEATHED MARINE FIBER OPTIC CABLES

INSTALLATION OPERATING ApproximateDRAKA USA Number Pull Strength Bend Radius Tension Bend Radius Cable O.D. Cable WeightPart Number of Fibers Newtons (lbs) cm (in) Newtons (lbs) cm (in) mm (in) Kg/km (Lbs/mft)

S607T-02R-xxy 2 600 (135) 12.8 (5.0) 200 (45) 6.4 (2.5) 6.4 (.252) 45 (30)

S607T-04-xxy 4 600 (135) 14.6 (5.8 200 (45) 7.3 (2.9) 7.3 (.287) 51 (35)

S607T-06-xxy 6 600 (135) 17.0 (6.8) 200 (45) 8.5 (3.4) 8.5 (.335) 71 (48)

S607T-08-xxy 8 600 (135) 19.4 (7.6) 200 (45) 9.7 (3.8) 9.7 (.381) 93 (63)

S607T-10-xxy 10 600 (135) 22.0 (8.4) 200 (45) 11.0 (4.3) 11.0 (.431) 119 (80)

S607T-12-xxy 12 600 (135) 24.4 (9.6) 200 (45) 12.2 (4.8) 12.2 (.481) 149 (100)

S607T-16-xxy 16 2700 (600) 25.7 (10.2) 600 (135) 12.8 (5.1) 12.8 (.507) 150 (101)

S607T-18-xxy 18 2700 (600) 25.7 (10.2) 600 (135) 12.8 (5.1) 12.8 (.507) 148 (100)

S607T-24-xxy 24 2700 (600) 29.6 (11.6) 600 (135) 14.8 (5.8) 14.8 (.581) 356 (238)

S607T-36-xxy 36 2700 (600) 34.0 (13.4) 600 (135) 17.0 (6.7) 17.0 (.670) 484 (325)

S607T-48-xxy 48 2700 (600) 46.0 (18.1) 600 (135) 23.1 (9.1) 23.0 (.905) 600 (403)

Replace the xxy with the Fiber Designation in the fiber performance table below.NOTE: Fibers are not suitable for F07 crimp and cleave connector.Information is subject to change without notice. Consult factory for a variety of alternate constructions for specific applications.

FIBER PERFORMANCE62.5µm MULTIMODE 200µm MULTIMODE

Fiber Designation 62X 50H 200S 010X

Applicable Specification IEC 60793-2 Type A1b ITU G.651 & IEC 60793-2 Type A1a ITU G.651 & IEC 60793-2 Type A1a ITU G.652 Table C & D Requirements& IEC 60793-2 Type B1.1

Fiber Type Graded Index Graded Index Step Index Matched Clad

Core Diameter 62.5µm ± 2.5µm 50µm ± 2.5µm 200µm ± 5µm 8.3µm Nominal

Cladding Diameter 125µm ± 1µm 125µm ± 1µm 230µm ± 10µm 125µm ± 1µm

Coating Diameter 242µm ± 7µm 242µm ± 7µm 500µm ± 30µm 242µm ± 7µm

Buffer Diameter 900µm ± 50µm 50µm ± 2.5µm 900µm ± 50µm 900µm ± 50µm

Numerical Aperture 0.275 ± 0.015 0.200 ± 0.015 .037 Nominal (2m 5% intensity) N/A

Mode Field Diameter N/A N/A N/A 9.1µm ± 0.4µm

Attenuation 3.5 dB/Km @ 850nm 3.5 dB/Km @ 850nm 12.0 dB/Km @ 820nm 0.70 dB/Km @ 1310nm1.0 dB/Km @ 1300nm 1.0 dB/Km @ 1300nm 0.70 dB/Km @ 1550nm

Bandwidth ≥200 MHz/Km @ 850nm ≥500 MHz/Km @ 850nm ≥20 MHz/Km @ 820nm N/A≥500 MHz/Km @ 1300nm ≥500 MHz/Km @ 1300nm N/A

Dispersion N/A N/A N/A 3.0 ps/nm-Km @1285-1330nmN/A N/A N/A 18 ps/nm-Km @ 1550nm

Proof Test 100,000 psi 100,000 psi 100,000 psi 100,000 psi

CABLE PROPERTIESCrush (IEC 60794-1-E3) 3000 N/ 10 cmImpact (IEC 60794-1-E4) 20 impacts, 5JTorsion (IEC 60794-1-E7) + 1 turn / 2 m, 100 cyclesCable Bend (IEC 60794-1-E11) <0.1 dB/ + 6 turns

TEMPERATURE RANGEOperation -20ºC to +80ºCInstallation -10ºC to +60ºCStorage -40ºC to +80ºC

FIRE, SMOKE, AND TOXICITY CLASSIFICATIONSFlame retardant IEC 60332-3, CAT.A CAT A/F and IEEE 1202Smoke density IEC 61034-1 and IEC 61034-2Acid gas penetration IEC 60754-1 and IEC 60754-2

Toxicity NES 713www.DrakaMOG.com

Subject to change without prior notice

Bostrig Type P0807

Page 56 of 62

tight buffer construction2 to 4 fibers / singlemode or multimode / LSZH

≥≥

≥≥

≥≥≥

≥≥

Bostrig Type P bk0108.qxd 1/26/08 2:53 PM Page 56

50 µm MULTIMODE 8.3µm SINGLEMODE

DUSA_MOG54_0807

INSTALLATION OPERATING ApproximateDRAKA USA Number Pull Strength Bend Radius Tension Bend Radius Cable O.D. Cable WeightPart Number of Fibers Newtons (lbs) cm (in) Newtons (lbs) cm (in) mm (in) Kg/km (Lbs/mft)

S611T-02R-xxy 2 600 (135) 12.8 (5.0) 200 (45) 6.4 (2.5) 6.4 (.252) 45 (30)

S611T-04-xxy 4 600 (135) 14.6 (5.8 200 (45) 7.3 (2.9) 7.3 (.287) 51 (35)

S611T-06-xxy 6 600 (135) 17.0 (6.8) 200 (45) 8.5 (3.4) 8.5 (.335) 71 (48)

S611T-08-xxy 8 600 (135) 19.4 (7.6) 200 (45) 9.7 (3.8) 9.7 (.381) 93 (63)

S611T-10-xxy 10 600 (135) 22.0 (8.4) 200 (45) 11.0 (4.3) 11.0 (.431) 119 (80)

S611T-12-xxy 12 600 (135) 24.4 (9.6) 200 (45) 12.2 (4.8) 12.2 (.481) 149 (100)

S611T-16-xxy 16 2700 (600) 25.7 (10.2) 600 (135) 12.8 (5.1) 12.8 (.507) 150 (101)

S611T-18-xxy 18 2700 (600) 25.7 (10.2) 600 (135) 12.8 (5.1) 12.8 (.507) 148 (100)

S611T-24-xxy 24 2700 (600) 29.6 (11.6) 600 (135) 14.8 (5.8) 14.8 (.581) 356 (238)

S611T-36-xxy 36 2700 (600) 34.0 (13.4) 600 (135) 17.0 (6.7) 17.0 (.670) 484 (325)

S611T-48-xxy 48 2700 (600) 46.0 (18.1) 600 (135) 23.1 (9.1) 23.0 (.905) 600 (403)

Replace the xxy with the Fiber Designation in the fiber performance table below.NOTE: Fibers are not suitable for F07 crimp and cleave connector.Information is subject to change without notice. Consult factory for a variety of alternate constructions for specific applications.

FIBER PERFORMANCE62.5µm MULTIMODE 200µm MULTIMODE

Fiber Designation 62X 50H 200S 010X

Applicable Specification IEC 60793-2 Type A1b ITU G.651 & IEC 60793-2 Type A1a ITU G.651 & IEC 60793-2 Type A1a ITU G.652 Table C & D Requirements& IEC 60793-2 Type B1.1

Fiber Type Graded Index Graded Index Step Index Matched Clad

Core Diameter 62.5µm ± 2.5µm 50µm ± 2.5µm 200µm ± 5µm 8.3µm Nominal

Cladding Diameter 125µm ± 1µm 125µm ± 1µm 230µm ± 10µm 125µm ± 1µm

Coating Diameter 242µm ± 7µm 242µm ± 7µm 500µm ± 30µm 242µm ± 7µm

Buffer Diameter 900µm ± 50µm 50µm ± 2.5µm 900µm ± 50µm 900µm ± 50µm

Numerical Aperture 0.275 ± 0.015 0.200 ± 0.015 .037 Nominal (2m 5% intensity) N/A

Mode Field Diameter N/A N/A N/A 9.1µm ± 0.4µm

Attenuation 3.5 dB/Km @ 850nm 3.5 dB/Km @ 850nm 12.0 dB/Km @ 820nm 0.70 dB/Km @ 1310nm1.0 dB/Km @ 1300nm 1.0 dB/Km @ 1300nm 0.70 dB/Km @ 1550nm

Bandwidth ≥200 MHz/Km @ 850nm ≥500 MHz/Km @ 850nm ≥20 MHz/Km @ 820nm N/A≥500 MHz/Km @ 1300nm ≥500 MHz/Km @ 1300nm N/A

Dispersion N/A N/A N/A 3.0 ps/nm-Km @1285-1330nmN/A N/A N/A 18 ps/nm-Km @ 1550nm

Proof Test 100,000 psi 100,000 psi 100,000 psi 100,000 psi

CABLE PROPERTIESCrush (IEC 60794-1-E3) 3000 N/ 10 cmImpact (IEC 60794-1-E4) 20 impacts, 5JTorsion (IEC 60794-1-E7) + 1 turn / 2 m, 100 cyclesCable Bend (IEC 60794-1-E11) <0.1 dB/ + 6 turns

TEMPERATURE RANGEOperation -20ºC to +80ºCInstallation -10ºC to +60ºCStorage -40ºC to +80ºC

FIRE, SMOKE, AND TOXICITY CLASSIFICATIONSFlame retardant IEC 60332-3, CAT.A CAT A/F and IEEE 1202Smoke density IEC 61034-1 and IEC 61034-2Acid gas penetration IEC 60754-1 and IEC 60754-2

Toxicity NES 713www.DrakaMOG.com

Subject to change without prior notice

Bostrig Type P0807

Page 54 of 62

S611T MARINE FIBER OPTIC CABLES

tight buffer construction2 to 48 fibers / singlemode or multimode / LSZH

≥≥

≥≥

≥≥≥

≥≥

Bostrig Type P bk0108.qxd 1/26/08 2:53 PM Page 54

50 µm MULTIMODE 8.3µm SINGLEMODE

138

Page 146: Prysmian Draka - Marine & Offshore LV HV Cables

50 Ω Coaxial cable –2.7/7.3AF ‘Low Loss’ FRNC-C Coaxials basing upon DIN 47264, EN 50117-1 and IEC 61196-1

Standards applied DIN 47264; EN 50117-1; IEC 61196-1 Fire Rating Standards

Halogen Free IEC 60754-2 Low smoke IEC 61034-1,2 Flame propogation IEC 60332-1 Fire retardant IEC 60332-3-24 (cat. C)

Application RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of commercial electronics and radio frequency engineering wherever high quality is required, e.g.:

long service life and good ageing stability high abrasion resistance of sheath and resistance to permanent action of chemicals high flexibility and low attenuation minimum characteristic impedance deviations and good homogeneity use of standardized connectors

Construction

Inner conductor Bare copper wire, Ø 2.71 + 0.02 mm Insulation Foam skinned polyethylene (Foam-PE), Ø 7.25 + 0.10 mm Outer conductor Aluminium – PET – Aluminium foil

and copper braid, tinned (ca. 93% optical coverage) Sheath FRNC, black RAL 9005, Ø 10.3 + 0.2 mm

Technical Data Prod.number

Draka Comteq Designation Type Outer diameter

Weight of cable approx.

Copper content Tensile force

(inner/outer) (mm) (kg/km) (kg/km) (N) CK7550700 ‘Low Loss’ FRNC-C 2.7/7.3 AF 10.3 145.0 90.0 505

139

Page 147: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Minimal bending radius ≥ 50 mm without load (5 x outer diameter)

≥ 100 mm with load (10 x outer diameter) Temperature range, during operation during installation

-30°C upto + 70°C -15°C upto + 55°C

Electrical Properties (at 20°C ± 5°C) DC resistance Inner conductor 3.1 Ω/km . Outer conductor 4.7 Ω/km Mutual capacitance nom. 79 pF/km Characteristic impedance (50 ± 2) Ω Nominal velocity of propagation approx. 84 % Transfer Impedance 1 MHz < 5 mΩ/m . 10 MHz < 4 mΩ/m . 100 MHz < 2 mΩ/m Operating voltage 1.200 VrmsTest voltage Inner/outer conductor 5.000 VrmsScreening factor 100-1000 MHz > 90 dB 1000-3000 MHz > 80 dB Insulation resistance > 10 GΩ.km

Electrical data (at 20 °C)

f Attenuation Max. power rating Return Loss

(MHz) (dB/100m) (W) (dB)

(ambient temperature 40 °C and max. inner

conductor temperature 100 °C

(several peaks are allowed)

nominal maximal Frequency (dB)

1 0.4 17.328 10-450 MHz > 26

10 1.3 5.480 450-1000 MHz > 23

100 4.1 1.710 1 – 3 GHz > 18

200 5.7 1.132

500 9.3 716

800 12.2 585

1000 13.6 523

1500 16.7 427

2000 19.5 351

2500 22.1 325

3000 24.8 261

3500 27.1 240

4000 29.3 246

5250 34.3 216

5725 36.3 205

6000 37.2 200

www.DrakaMOG.com

Datacomm02_Jan_07

140

Page 148: Prysmian Draka - Marine & Offshore LV HV Cables

50 Ω Coaxial cable - RG 213 FRNC-B RG-Cables acc. To MIL-C-17F and MIL-C-17G

Standards applied

acc. to MIL-C-17F and MIL-C-17G Fire Rating Standards Halogen Free IEC 60754-2 Low smoke IEC 61034-1,2 Flame propogation IEC 60332-1 F ire retardant IEC 60332-3-23 (cat. B)

Application RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of commercial electronics and radio frequency engineering wherever high quality is required, e.g.:

long service life and good ageing stability high abrasion resistance of sheath and resistance to permanent action of chemicals high flexibility and low attenuation minimum characteristic impedance deviations and good homogeneity use of standardized connectors

Construction

Inner conductor Stranded copper wires 7 x 0.75, Ø 2.25 + 0.01 mm Insulation Polyethylene (PE), Ø 7.25 + 0.05 mm Braid Bare copper braid (ca. 96% optical coverage) Sheath FRNC, black Ø 10.3 + 0.15 mm

Technical Data Prod.number

Draka Comteq Designation Type Outer diameter

Weight of cable approx.

Copper content Tensile force

(inner/outer) (mm) (kg/km) (kg/km) (N) CK2775400 M17/074 RG 214 2.25L/7.25 10.3 157 86.7 470

141

Page 149: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Minimal bending radius ≥ 50 mm without load (5 x outer diameter)

≥ 100 mm with load (10 x outer diameter) Temperature range, during operation during installation

-40°C upto + 85°C -15°C upto + 55°C

Electrical Properties (at 20°C ± 5°C) DC resistance Inner conductor 5.7 Ω/km Outer conductor 3.9 Ω/km Mutual capacitance nom. 100 pF/km Characteristic impedance (50 ± 2) Ω Nominal velocity of propagation approx. 66 % Propagation delay ≤ 427 ns/100m Delay skew ≤ 12 ns/100m Operating voltage 3.700 VrmsTest voltage Inner/outer conductor 10.000 Vrms

Electrical data (at 20 °C)

f Attenuation Max. power rating Return Loss

(MHz) (dB/100m) (W) (dB)

(ambient temperature 25 °C and max. inner

conductor temperature 70 °C

(several peaks are allowed)

1 28.0

10 1.8 2.300

100 6.8 920

200 9.0 570

400 14.4 380

1.000 24.7 210 23.5

1.500 31.5 170

2.000 36.4 140

3.000 46.6 100

5.200 62.0 73

5.800 67.0 67

www.DrakaMOG.com

Datacomm03_Jan_07 142

Page 150: Prysmian Draka - Marine & Offshore LV HV Cables

50 Ω Coaxial cable - RG 214 FRNC-B RG-Cables acc. To MIL-C-17F and MIL-C-17G

Standards applied

Acc. To MIL-C-17F and MIL-C-17G Fire Rating Standards Halogen Free IEC 60754-2 Low smoke IEC 61034-1,2 Flame propogation IEC 60332-1 F ire retardant IEC 60332-3-23 (cat. B)

Application RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of commercial electronics and radio frequency engineering wherever high quality is required, e.g.:

long service life and good ageing stability high abrasion resistance of sheath and resistance to permanent action of chemicals high flexibility and low attenuation minimum characteristic impedance deviations and good homogeneity use of standardized connectors

Construction

Inner conductor Stranded copper wires, silver plated 7 x 0.75, Ø 2.25 + 0.01 mm Insulation Polyethylene (PE), Ø 7.25 + 0.05 mm 1st braid Bare copper braid, silver plated (ca. 94% optical coverage) 2nd braid Bare copper braid, silver plated (ca. 97% optical coverage) Sheath FRNC, black Ø 10.8 + 0.15 mm

Technical Data Prod.number

Draka Comteq Designation Type Outer diameter

Weight of cable approx.

Copper content Tensile force

(inner/outer) (mm) (kg/km) (kg/km) (N) CK2950901 M17/075 RG 214 FRNC-B 2.25Ls/7.25Ds 10.8 200 132.9 730

143

Page 151: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Minimal bending radius ≥ 50 mm without load (5 x outer diameter)

≥ 100 mm with load (10 x outer diameter) Temperature range, during operation during installation

-40°C upto + 85°C -15°C upto + 55°C

Electrical Properties (at 20°C ± 5°C) DC resistance Inner conductor 5.7 Ω/km . 1st braid 6.2 Ω/km . 2nd braid 6.2 Ω/km Mutual capacitance nom. 100 pF/km Characteristic impedance (50 ± 2) Ω Nominal velocity of propagation approx. 66 % Maximum operating frequency 11 GHz Operating voltage 3.700 VrmsTest voltage Inner/outer conductor 10.000 Vrms

Electrical data (at 20 °C)

f Attenuation Max. power rating Return Loss

(MHz) (dB/100m) (W) (dB)

(ambient temperature 25 °C and max. inner

conductor temperature 70 °C

(several peaks are allowed)

50 4.9 1.500 -

100 6.9 920 > 23

400 15.1 330 -

1.000 26.5 160 > 20

3.000 50.6 75 > 19

5.000 - - > 18

5.200 67.8 61 -

5.800 73.0 56 -

11.000 - - > 17

www.DrakaMOG.com

Datacomm04_Jan_07 144

Page 152: Prysmian Draka - Marine & Offshore LV HV Cables

50 Ω Coaxial cable - RG 214 PVC RG-Cables acc. To MIL-C-17F and MIL-C-17G

Standards applied

Acc. To MIL-C-17F and MIL-C-17G Fire Rating Standards F lame propogation IEC 60332-1

Application RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of commercial electronics and radio frequency engineering wherever high quality is required, e.g.:

long service life and good ageing stability high abrasion resistance of sheath and resistance to permanent action of chemicals high flexibility and low attenuation minimum characteristic impedance deviations and good homogeneity use of standardized connectors

Construction

Inner conductor Stranded copper wires, silver plated 7 x 0.75, Ø 2.25 + 0.01 mm Insulation Polyethylene (PE), Ø 7.25 + 0.05 mm 1st braid Bare copper braid, silver plated (ca. 94% optical coverage) 2nd braid Bare copper braid, silver plated (ca. 97% optical coverage) Sheath PVC, black Ø 10.8 + 0.15 mm

Technical Data Prod.number

Draka Comteq Designation Type Outer diameter

Weight of cable approx.

Copper content Tensile force

(inner/outer) (mm) (kg/km) (kg/km) (N) CK2775700 M17/075 RG 214 2.25Ls/7.25Ds 10.8 200 132.9 730

145

Page 153: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Minimal bending radius ≥ 50 mm without load (5 x outer diameter)

≥ 100 mm with load (10 x outer diameter) Temperature range, during operation during installation

-40°C upto + 85°C -15°C upto + 55°C

Electrical Properties (at 20°C ± 5°C) DC resistance Inner conductor 5.7 Ω/km . 1st braid 6.2 Ω/km . 2nd braid 6.2 Ω/km Mutual capacitance nom. 100 pF/km Characteristic impedance (50 ± 2) Ω Nominal velocity of propagation approx. 66 % Maximum operating frequency 11 GHz Operating voltage 3.700 VrmsTest voltage Inner/outer conductor 10.000 Vrms

Electrical data (at 20 °C)

f Attenuation Max. power rating Return Loss

(MHz) (dB/100m) (W) (dB)

(ambient temperature 25 °C and max. inner

conductor temperature 70 °C

(several peaks are allowed)

50 4.9 1.500 -

100 6.9 920 > 23

400 15.1 330 -

1.000 26.5 160 > 20

3.000 50.6 75 > 19

5.000 - - > 18

5.200 67.8 61 -

5.800 73.0 56 -

11.000 - - > 17

www.DrakaMOG.com

Datacomm05_Jan_07 146

Page 154: Prysmian Draka - Marine & Offshore LV HV Cables

50 Ω Coaxial cable - RG 223 FRNC-B RG-Cables acc. To MIL-C-17F and MIL-C-17G

Standards applied

Acc. To MIL-C-17F and MIL-C-17G Fire Rating Standards Halogen Free IEC 60754-2 Low smoke IEC 61034-1,2 Flame propogation IEC 60332-1 F ire retardant IEC 60332-3-24 (cat. C)

Application RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of commercial electronics and radio frequency engineering wherever high quality is required, e.g.:

long service life and good ageing stability high abrasion resistance of sheath and resistance to permanent action of chemicals high flexibility and low attenuation minimum characteristic impedance deviations and good homogeneity use of standardized connectors

Construction

Inner conductor Stranded copper wires, silver plated Ø 0.9 + 0.01 mm Insulation Polyethylene (PE), Ø 2.95 + 0.05 mm 1st braid Bare copper braid, silver plated (ca. 96% optical coverage) 2nd braid Bare copper braid, silver plated (ca. 96% optical coverage) Sheath FRNC, black Ø 5.4 + 0.10 mm

Technical Data Prod.number

Draka Comteq Designation Type Outer diameter

Weight of cable approx.

Copper content Tensile force

(inner/outer) (mm) (kg/km) (kg/km) (N) CK7676500 M17/84 RG 223 FRNC-B 0.89s/2.95Ds 5.4 54.7 40.5 240

147

Page 155: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Minimal bending radius ≥ 25 mm without load (5 x outer diameter)

≥ 50 mm with load (10 x outer diameter) Temperature range, during operation during installation

-40°C upto + 85°C -15°C upto + 55°C

Electrical Properties (at 20°C ± 5°C) DC resistance Inner conductor 29.1 Ω/km . 1st braid 13.5 Ω/km . 2nd braid 13.5 Ω/km Mutual capacitance nom. 100 pF/km Characteristic impedance (50 ± 2) Ω Nominal velocity of propagation approx. 66 % Maximum operating frequency 12.4 GHz Operating voltage 1.400 VrmsTest voltage Inner/outer conductor 5.000 Vrms

Electrical data (at 20 °C)

f Attenuation Max. power rating Return Loss

(MHz) (dB/100m) (W) (dB)

(ambient temperature 25 °C and max. inner

conductor temperature 70 °C

(several peaks are allowed)

Frequency (dB)

50 9.8 350 100 MHz > 27.0

400 28.4 86 1 GHz > 23.5

1.000 45.9 50 2 GHz > 21.5

3.000 83.1 32 4-5 GHz > 21.0

5.200 112.7 24 10 GHz > 20.0

5.800 120.6 22

www.DrakaMOG.com

Datacomm06_Jan_07 148

Page 156: Prysmian Draka - Marine & Offshore LV HV Cables

50 Ω Coaxial cable - RG 223 PVC RG-Cables acc. To MIL-C-17F and MIL-C-17G

Standards applied

Acc. To MIL-C-17F and MIL-C-17G Fire Rating Standards F lame propogation IEC 60332-1

Application RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of commercial electronics and radio frequency engineering wherever high quality is required, e.g.:

long service life and good ageing stability high abrasion resistance of sheath and resistance to permanent action of chemicals high flexibility and low attenuation minimum characteristic impedance deviations and good homogeneity use of standardized connectors

Construction

Inner conductor Stranded copper wires, silver plated Ø 0.9 + 0.01 mm Insulation Polyethylene (PE), Ø 2.95 + 0.05 mm 1st braid Bare copper braid, silver plated (ca. 96% optical coverage) 2nd braid Bare copper braid, silver plated (ca. 96% optical coverage) Sheath PVC, black Ø 5.4 + 0.10 mm

Technical Data Prod.number

Draka Comteq Designation Type Outer diameter

Weight of cable approx.

Copper content Tensile force

(inner/outer) (mm) (kg/km) (kg/km) (N) CK2776500 M17/84 RG 223 0.89s/2.95Ds 5.4 54.7 40.5 240

149

Page 157: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Minimal bending radius ≥ 25 mm without load (5 x outer diameter)

≥ 50 mm with load (10 x outer diameter) Temperature range, during operation during installation

-40°C upto + 85°C -15°C upto + 55°C

Electrical Properties (at 20°C ± 5°C) DC resistance Inner conductor 29.1 Ω/km . 1st braid 13.5 Ω/km . 2nd braid 13.5 Ω/km Mutual capacitance nom. 100 pF/km Characteristic impedance (50 ± 2) Ω Nominal velocity of propagation approx. 66 % Maximum operating frequency 12.4 GHz Operating voltage 1.400 VrmsTest voltage Inner/outer conductor 5.000 Vrms

Electrical data (at 20 °C)

f Attenuation Max. power rating Return Loss

(MHz) (dB/100m) (W) (dB)

(ambient temperature 25 °C and max. inner

conductor temperature 70 °C

(several peaks are allowed)

Frequency (dB)

50 9.8 350 100 MHz > 27.0

400 28.4 86 1 GHz > 23.5

1.000 45.9 50 2 GHz > 21.5

3.000 83.1 32 4-5 GHz > 21.0

5.200 112.7 24 10 GHz > 20.0

5.800 120.6 22

www.DrakaMOG.com

Datacomm07_Jan_07 150

Page 158: Prysmian Draka - Marine & Offshore LV HV Cables

6 FOILS 4x2x0.57 (AWG 23) MULTIMEDIA LSHF-FR Shielded 100Ω Data cable ISO/IEC 11801 CAT-7

Standards applied

International ISO/IEC 11801 2nd ed. USA ANSI/EIA/TIA 568A Europe NEN-EN 50173 Cat 7 NEN 11156-5 (IEC 61156) C onstruction NEN-EN 50288-2-1

Application Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10Gbase-T; IEEE 802.5 16MB; ISDN; TPDDI; ATM

Fire Rating Standards Halogen Free IEC 60754-2 Low smoke IEC 61034-1,2 Flame propogation IEC 60332-1 Fire retardant IEC 60332-3-24 (cat. C)

Construction

Conductor Bare copper wire Ø 0.57 mm (AWG23) Insulation Polyethylene, Ø 1.4 mm Pair screen Al-laminated plastic foil,

Patented wrapping of two pairs each Twisting 2 cores to the pair Cable lay up 4 pair to the core Overall sheath Copper braid, tinned (ca. 65% coverage) Sheath LSHF, mellon orange RAL 1028 Sheath marking DRAKA COMTEQ 6FOIL S/FTP 4x2x0.57 MULTIMEDIA

Core identification (in accordance ISO/IEC 11801 2nd edition) Pair 1 white/blue and blue, Pair 2 white/orange and orange, Pair 3 white/green and green, Pair 4 white/brown and brown

Technical Data Prod.number

Draka Comteq Designation No. of cores

and cond.area

Outer diameter

Fire Load

Weight of cable

approx. Copper content

Tensile force

(mm2) (mm) (MJ/km) (kWh/m) (kg/km) (kg/km) (N) CD7679731 S/FTP AWG23 LSHF-FR 2x2x0.57 7.9 642 0.178 81 39 340

151

Page 159: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Bending radius ≥ 35 mm without load

≥ 70 mm with load Temperature range, during operation during installation

-20°C upto + 60°C 0°C upto + 50°C

Electrical Properties (at 20°C ± 5°C) DC loop resistance ≤ 135 Ω /km Resistance unbalance ≤ 2% Insulation resistance (500 V) ≥ 2000 MΩ *km Capacitance at 800 Hz nom. 43 nF/km Capacitance unbalance (pair to ground) ≤ 1500 pF/km Characteristic impedance (1-100 MHz) (100 ± 15) Ω (100-250 MHz) (100 ± 18) Ω (250-600 MHz) (100 ± 25) Ω (600-1200 MHz) (100 ± 30) Ω Nominal velocity of propagation approx. 79 % Propagation delay ≤ 427 ns/100m Delay skew ≤ 12 ns/100m Test voltage (DC, 1 min) Core/Core and Core/Screen

1000 V

Transfer impedance at 1 MHz ≤ 5 mΩ /m at 10 MHz ≤ 5 mΩ /m at 30 MHz ≤ 15 mΩ /m at 100 MHz ≤ 30 mΩ /m

Nominal transmission characteristics acc. to Category 7 (at 20 °C)

f Attenuation NEXT PS-NEXT ACR PS-ACR ELFEXT PS-ELFEXT Return loss

(MHz) (dB/100m) (dB) (dB) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB)

1.0 2.0 117 114 115 112 105 103 20

4.0 3.6 117 114 113 110 93 91 23

10.0 5.7 117 114 112 109 85 83 25

16.0 7.2 114 111 107 104 81 79 25

20.0 8.1 113 110 105 102 79 77 25

31.2 10.1 110 107 100 97 75 73 24

62.5 14.5 105 102 91 88 69 67 22

100.0 18.5 102 99 84 81 65 63 20

125.0 21.1 101 98 80 77 63 61 19

155.5 23.4 100 97 76 73 61 59 19

175.0 25.1 99 96 74 71 60 58 18

200.0 26.8 98 95 71 68 59 57 18

250.0 30.1 96 93 66 63 57 55 17

300.0 33.0 95 92 62 59 55 53 17

450.0 42.6 93 90 50 47 52 50 17

600.0 49.0 91 88 42 39 49 47 17

750.0 63.3 87 84 24 21 45 43 -

900.0 69.3 86 83 17 14 43 41 -

1000.0 77.5 85 82 7.3 4.3 41 39 -

www.DrakaMOG.com

Datacomm16_Jan_07

152

Page 160: Prysmian Draka - Marine & Offshore LV HV Cables

75 Ω CATV cable – 1.0/4.8 AF FRNC-C CATV Drop Cable

Standards applied

S creening efficiency EN 50117-1

Application Drop cables are used in TV signal distribution networks and as antenna cable for terrestric and satellite broadcast systems.

Fire Rating Standards Halogen Free IEC 60754-2 Low smoke IEC 61034-1,2 Flame propogation IEC 60332-1 Fire retardant IEC 60332-3-24 (cat. C)

Construction

Inner conductor Bare copper wire, Ø 1.0 mm Insulation Foam skinned polyethylene (Foam-PE), Ø 4.65 + 0.10 mm Outer conductor Aluminium – PET – Aluminium foil

under copper braid, tinned (ca. 40% optical coverage) Sheath FRNC-C, white Ø 6.8 + 0.2 mm

Technical Data Prod.number

Draka Comteq Designation Type Outer diameter

Weight of cable approx.

Copper content Tensile force

(inner/outer) (mm) (kg/km) (kg/km) (N) CT2850402 1.0/4.8AF FRNC-C 1.0/4.8 AF 6.8 45.0 14.5 110

153

Page 161: Prysmian Draka - Marine & Offshore LV HV Cables

Electrical Properties (at 20°C ± 5°C) DC resistance Inner conductor 22 Ω/km . Outer conductor 25 Ω/km Mutual capacitance nom. 55 pF/km Characteristic impedance (75 ± 2) Ω Nominal velocity of propagation approx. 85 % Screening factor 30-1000 MHz > 80 dB

Electrical data (at 20 °C)

f Attenuation Return Loss

(MHz) (dB/100m) (dB)

(several peaks are allowed)

nominal Frequency (dB)

5 1.6 5 – 30 MHz > 26

50 4.6 30 – 470 MHz > 23

100 6.4 480 – 862 MHz > 20

200 8.9 862 – 2150 MHz > 18

400 12.7

862 18.9

950 19.8

1000 20.5

1350 23.8

1600 26.4

1750 27.6

2150 30.8

2550 33.6

3000 36.5

www.DrakaMOG.com

Datacomm08_Jan_07 154

Page 162: Prysmian Draka - Marine & Offshore LV HV Cables

75 Ω CATV cable – 1.6/7.3 AF FRNC CATV Distribution and Drop Cable

Standards applied

Screening efficiency acc. to EN 50117-1 and draft EN 50117-2-2, 4 a 5 May 2002. EN 50083-2/A1 screening class A

Application Drop cables are used in TV signal distribution networks and as antenna cable for terrestric and satellite broadcast systems.

Fire Rating Standards Halogen Free IEC 60754-2 Low smoke IEC 61034-1,2 Flame propogation IEC 60332-1 Fire retardant IEC 60332-3-24 (cat. C)

Construction

Inner conductor Bare copper wire, Ø 1.6 mm Insulation Foam skinned polyethylene (Foam-PE), Ø 7.2 mm Outer conductor Aluminium – PET – Aluminium foil

under copper braid, tinned (ca. 60% optical coverage) Sheath FRNC-C, black Ø 10.0 + 0.3 mm

Technical Data Prod.number

Draka Comteq Designation Type Outer diameter

Weight of cable approx.

Copper content

Bending radius Tensile force

(inner/outer) (mm) (kg/km) (kg/km) (mm) (N) CT2760901 1.6/7.3AF FRNC-C 1.6/7.3 AF 10.0 85.0 35.3 50.0 300

155

Page 163: Prysmian Draka - Marine & Offshore LV HV Cables

Electrical Properties (at 20°C ± 5°C) DC resistance Inner conductor 9 Ω/km . Outer conductor 14 Ω/km Mutual capacitance nom. 55 pF/km Characteristic impedance (75 ± 2) Ω Nominal velocity of propagation approx. 80 % Screening factor 30-1000 MHz > 80 dB

Electrical data (at 20 °C)

f Attenuation Return Loss

(MHz) (dB/100m) (dB)

(several peaks are allowed)

nominal Frequency (dB)

5 1.0 5 – 30 MHz > 26

50 3.0 30 – 470 MHz > 23

100 4.2 480 – 862 MHz > 20

200 6.0 862 – 2150 MHz > 18

400 8.8

862 12.9

1000 14.6

1350 17.5

1600 19.3

1750 20.2

2150 23.1

2550 25.2

3000 27.8

www.DrakaMOG.com

Datacomm09_Jan_07 156

Page 164: Prysmian Draka - Marine & Offshore LV HV Cables

75 Ω CATV cable – Coax10 AD 10S FRNC-C CATV Drop Cable

Standards applied

Screening efficiency

Screening Class A acc. to EN 50117-2-1, EN 50117-2-2, EN 50117-2-4 and EN 50117-2-5 further EN 500083-2A1, EN 50117-1.

Application Drop cables are used in private and commercial TV signal distribution networks and as antenna cable for terrestrial and satellite broadcast systems. This predestined head-end cable is manufactured with vacuum technology. The cable layers thereby have high friction forces which allow automatic dismantling also at small lengths.

Fire Rating Standards Halogen Free IEC 60754-2 Low smoke IEC 61034-1,2 Flame propogation IEC 60332-1 Fire retardant IEC 60332-3-24 (cat. C)

Construction

Inner conductor Bare copper wire, Ø 1.0 mm Insulation Gas injected foam polyethylene (Foam-PE), Ø 4.55 mm Outer conductor Aluminium – PET foil, longitudinal, bonded to the insulation,

under copper braid, tinned (ca. 70% optical coverage) and Aluminium – PET foil longitudinal, bonded to the sheath, Ø 4.55 mm

Sheath FRNC-C, black Ø 6.8 + 0.2 mm Marking DRAKA COMTEQ – OAX10 AD S + meter marking + batch number

Technical Data Prod.number

Draka Comteq Designation Outer diameter

Weight of cable approx.

Copper content

Bending radius Tensile force

(mm) (kg/km) (kg/km) (mm) (N) CK2689305 Coax10 AD 10 S FRNC-C 6.8 47.0 21.9 35.0 175

157

Page 165: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Minimal bending radius Without load ≥ 30 mm (5 x outer diameter) . With load ≥ 65 mm (10 x outer diameter) Temperature range during operation -40°C upto + 85°C . during installation -15°C upto + 55°C Corrosiveness FRNC-C acc. to IEC 60754-2 Friction forces between cable layers

Dielectric – foil – braid – foil - sheath. > 80 N (Pull test with 300 mm overlapping zone)

Inner conductor – dielectric (acc. to DIN EN 50 289-3-17)

> 15 N (Pull test with 50 mm overlapping zone)

Electrical Properties (at 20°C ± 5°C) DC resistance Inner conductor 22 Ω/km . Outer conductor 14 Ω/km Mutual capacitance nom. 52 pF/km Characteristic impedance (75 ± 2) Ω Nominal velocity of propagation approx. 85 % Screening factor 30-1000 MHz > 110 dB 1 - 2 GHz > 100 dB 2 - 3 GHz > 100 dB Transfer impedance 5 - 30 MHz > 5 mΩ.m Electrical strength Diëlectric 2 kVDC 1 min Sheath 3.75 kVDC 1 min

Electrical data (at 20 °C)

f Attenuation Return Loss

(MHz) (dB/100m) (dB)

(several peaks are allowed)

nominal Frequency (dB)

5 1.6 5 – 30 MHz > 26

50 4.3 30 – 470 MHz > 24

100 6.2 470 – 1000 MHz > 20

200 8.7 1000 – 3000 MHz > 18

400 12.5

862 18.6

950 19.8

1350 23.7

1750 27.2

2150 30.5

3000 36.9

www.DrakaMOG.com

Datacomm10_Jan_07 158

Page 166: Prysmian Draka - Marine & Offshore LV HV Cables

Analogue Audio Cable 110 Ω AC10 SS 26/7 10P Analogue Audio Cable based upon ARD-specification and acc. to AES/EBU-recommendation

Fire Rating Standards

Halogen Free IEC 60754-2 Low smoke IEC 61034-1,2 Flame propogation IEC 60332-1 F ire retardant IEC 60332-3-24 (cat. C)

Application Audio cables are used in professional broadcasting systems for the transmission of analogue and digital signals.

Construction

Inner conductor Stranded bare copper wires, Ø 0.48 mm (0.14 mm² / AWG 26/7) Insulation Foam skinned polyethylene (Foam-PE), Ø 1.2 mm Pair stranding Two cores twisted to the pair Pair identification a – core: white, b – core: blue

(the above colours in regular intervals) Pair screen Aluminium – PET foil, aluminium inside and stranded copper drain wires,

tinned. Pair insulation of the one-pair cable

PET foil.

Pair insulation of the multi-pair cable

FRNC, flame retardant copolymer

Colour and identification

Grey RAL 7001 with number printing

Cable lay-up n-pairs twisted in layers Overall screen Aluminium-PET foil under copper braid, tinned. Sheath FRNC-C, grey RAL 7001 Ø 13.7 mm Marking DRAKA MULTIMEDIA CABLE – GERMANY – AC 10 SS 26/7 10P AES/EBU

Technical Data Prod.number

Draka Comteq Designation Type Outer diameter

Weight of cable approx.

Copper content Tensile force

(nxnxmm) (mm) (kg/km) (kg/km) (N) CT7651811 AC10 SS 26/7 10P PiMF 10x2x20.48 13.7 195.0 110.9 550

159

Page 167: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Minimal bending radius Without load ≥ 130 mm (10 x outer diameter) . With load ≥ 200 mm (15 x outer diameter) Temperature range -30°C upto + 70°C Corrosiveness FRNC-C acc. to IEC 60754-2

Electrical Properties (at 20°C ± 5°C) DC loop resistance < 288 Ω/km Insulation resistance ≥ 2000 MΩ.km Mutual capacitance at 800 Hz Nom. 45 nF/km Capacitance unbalance (pair to ground) < 1200 pF/km Nominal velocity of propagation approx. 78 % Test voltage (50 Hz, 1min) Core/core and core/screen)

700 VRMS

Characteristic impedance (6 MHz) 110 Ω ± 10% Transfer impedance up to 10 MHz > 10 mΩ.m up to 100 MHz > 100 mΩ.m

Electrical data (at 20 °C)

f NEXT Attenuation

(MHz) (dB/300m) (dB/100m)

0.015 85 0.55

1.0 85 3.0

4.0 90 5.3

10.0 90 8.1

20.0 85 11.5

www.DrakaMOG.com

Datacomm11_Jan_07 160

Page 168: Prysmian Draka - Marine & Offshore LV HV Cables

D92aici.e20 12.09.2007 14:51

Page 1 of 2

Flame retardant AICI-I/O/RM-W

Optical cable for industrial environments. The cable is suitable for both indoor and outdoor installation. Continiuous submergence in water is not recommended. Outer sheath is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC60811-2-1. The cable is reinforced with a steel wire braiding between the two sheaths. Strength elements of glass yarn around the cable core allow easy installation of long lengths. The 0.9 mm tight buffer is easy to strip allowing fast and reliable splicing and connector mounting. Each fibre is colour coded for easy identification. The outer sheath is marked to show fibre type and cable type.

Armoured industrial cable

AICI-I/O/RM-W Indoor and outdoor Flame retardant and halogen free Steel wire braiding Tight buffer

Secondary coated fibre Water swellable material Glass yarn Inner sheath Steel wire braiding Outer sheath

Weight and dimensions Number of fibres Secondary coating

[mm]

Outer diameter

[mm]

Weight

[kg/km]

Tensile strength* [Inst./oper.]

[N] 4 0.9 8.2 90 700/250 8 0.9 9.4 125 800/350 12 0.9 10.3 145 1200/500 24 0.9 12.0 185 1700/750

Cable properties *Tensile strength (IEC 60794-1-2E1) Max tensile load during installation Max tensile load during operation

See aboveSee above

Temperature window Operation Installation Storage

-40°C to +70°C-10°C to +70°C-40°C to +70°C

Crush (IEC 60794-1-2E3) 2000 N/10cm Water tightness* (IEC 60794-1-2F5B) < 3 m/24 hoursImpact (IEC 60794-1-2E4) 1 impacts, 25J Fire and smoke classifications Torsion (IEC 60794-1-2E7) ± 1 turn/1m IEC 60332-1 Cable bending Minimum bending diameter Cable bend (IEC 60794-1-2E11) Flexibility (IEC 60794-1-2E8)

15x outer diameter<0.5 dB/ ± 5 turn

1000 cycles

IEC 60332-3-22 (Cat. A) IEC 60332-3-24 (Cat. C) IEC 61034 IEC 60754-1 IEC 60754-2

Chemical reistance Mineral oils IRM 902 (IEC60811-2-1) Diesel - IRM 903 (IEC60811-2-1)

- 7 days/23°C - 4 hours/70°C - 7 days/23°C - 4 hours/70°C

*) – Steel wire braiding is not watertight.

www.drakaMOG.com Subject to change without prior notice

161

Page 169: Prysmian Draka - Marine & Offshore LV HV Cables

D92aici.e20 12.09.2007 14:51

Page 2 of 2

Flame retardant AICI-I/O/RM-W

www.drakaMOG.com Subject to change without prior notice

Ordering information 9/125 fibre(SMF652D), Black** 50/125 fibre(MMF50HiCap), Black** 62.5/125 fibre(MMF62HiCap), Black**

Part no. Cable code Part no. Cable code Part no. Cable code 695420 G4-9/125 AICI-I/O/RM-W 695422 G4-50/125 AICI-I/O/RM-W 695424 G4-62.5/125 AICI-I/O/RM-W 695440 G8-9/125 AICI-I/O/RM-W 695442 G8-50/125 AICI-I/O/RM-W 695444 G8-62.5/125 AICI-I/O/RM-W 695450 G12-9/125 AICI-I/O/RM-W 695452 G12-50/125 AICI-I/O/RM-W 695454 G12-62.5/125 AICI-I/O/RM-W 695480 G24-9/125 AICI-I/O/RM-W 695482 G24-50/125 AICI-I/O/RM-W 695484 G24-62.5/125 AICI-I/O/RM-W **)-Standard colour of outer sheath We reserve the right to alter this specification without notice. Optical fibres

Fibre type 9/125

HiCap 50/125

MaxCap 50/125

HiCap 62.5/125

Reference(DNK) SMF652D MMF50HiCap MMF50MaxCap MMF62HiCap IEC60793-2-50 category B.1.3 A1a A1a.2 A1bIEC11801 classification OS1 and OS2 OM2 OM3 OM1ITU-T type G652.D G651 G651 - Gigabit Ethernet maximum distances SX-serial(850 nm) LX-serial(1310 nm) 5000m

750 m2000 m

900 m 550 m

500 m1000 m

10Gigabit Ethernet maximum distances SX-serial(850 nm) LX-serial(1310 nm) 10000 m

110 m

300 m

65 m

Core diameter See mode field diameter 50 ± 2.5 μm 50 ± 2.5 μm 62.5 ± 2.5 μmMode field diameter 1310 nm 9.2 ± 0.4 μm

1550 nm 10.3 ± 0.5 μm

Cladding diam. loose tube 125 ± 0.7 μm 125 ± 2.0 μm 125 ± 2.0 μm 125 ± 2.0 μmCladding diam. tight buffer 125 ± 0.7 μm 125 ± 2.0 μm 125 ± 2.0 μm 125 ± 2.0 μmPrimary coating diameter (nominal)

242 ± 7 μm 250 μm 250 μm 250 μm

Attenuation (Typical values) 850 nm 1300 nm 1310 nm 1550 nm

0.33 – 0.37 dB/km 0.19 – 0.23dB/km

≤ 2.5 dB/km ≤ 0.7 dB/km

≤ 2.5 dB/km ≤ 0.7 dB/km

≤ 3.0 dB/km ≤ 0.7 dB/km

Attenuation (Maximum values) 850 nm 1300 nm 1310 nm 1550 nm

≤ 0.40 dB/km ≤ 0.25 dB/km

≤ 2.7 dB/km ≤ 0.8 dB/km

≤ 2.7 dB/km ≤ 0.9 dB/km

≤ 3.2 dB/km ≤ 1.0 dB/km

Bandwidth(OFL*) 850 nm 1300 nm

>600 MHz⋅km>1200 MHz⋅km

>1500 MHz⋅km

>500 MHz⋅km >200 MHz⋅km>600 MHz⋅km

Chromatic Dispersion 1285-1330 nm 1550 nm

≤ 3 ps/nm⋅km≤ 18 ps/nm⋅km

Polarization Mode Disp. PMD Link Design Value ** Max. Individual Fibre

≤ 0.06 √km≤ 0.1 √km

Numerical aperture 0.13 ( nominal) 0.200 ± 0.015 0.200 ± 0.015 0.275 ± 0.015Minimum permanent bending diameter 50 mm 50 mm

50 mm 50 mm

* Over Filled Launch methode(OFL). Modal Bandwidth in accordance with IEC60793-1-41. ** According to IEC 60794-3, Ed.3 (Q=0.01%) Other fibre types and qualities are available on request.

Rev: 09/07

162

Page 170: Prysmian Draka - Marine & Offshore LV HV Cables

Cat. 5e SF/UTP 4x2x0.51 (AWG 24) FRNC-C Shielded 100Ω Data cable ISO/IEC 11801 CAT-5e

Standards applied

International ISO/IEC 11801 2nd ed. USA ANSI/EIA/TIA 568A Europe NEN-EN 50173 Cat 5e NEN 11156-5 (IEC 61156) C onstruction NEN-EN 50288-2-1

Application Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; ATM

Fire Rating Standards Halogen Free IEC 60754-2 Low smoke IEC 61034-1,2 Flame propogation IEC 60332-1 Fire retardant IEC 60332-3-24 (cat. C)

Construction

Conductor Bare copper wire Ø 0.51 mm (AWG24) Insulation Polyethylene, Ø 1.1 mm Twisting 2 cores to the pair Cable la yup 4 pair to the core Overall sheath Al-laminated plastic foil and Copper braid, tinned (coverage > 40%) Sheath LSHF, grey RAL 7035 Sheath marking DRAKA COMTEQ MULTIMEDIA SF/UTP CAT-5e 4x2x0.51

Core identification (in accordance ISO/IEC 11801 2nd edition) Pair 1 white/blue and blue, Pair 2 white/orange and orange, Pair 3 white/green and green, Pair 4 white/brown and brown

Technical Data Prod.number

Draka Comteq Designation No. of cores

and cond.area

Outer diameter

Fire Load

Weight of cable

approx. Copper content

Tensile force

(mm2) (mm) (MJ/km) (kWh/m) (kg/km) (kg/km) (N) CD7677530 SF/UTP Cat.5e FRNC-C 2x2x0.51 6.4 433 0.120 47 27 120

163

Page 171: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Bending radius ≥ 25 mm without load

≥ 50 mm with load Temperature range, during operation during installation

-20°C upto + 60°C 0°C upto + 50°C

Electrical Properties (at 20°C ± 5°C) DC loop resistance ≤ 190 Ω /km Resistance unbalance ≤ 2% Insulation resistance (500 V) ≥ 2000 MΩ *km Capacitance at 800 Hz nom. 48 nF/km Capacitance unbalance (pair to ground) ≤ 1500 pF/km Characteristic impedance (1-100 MHz) (100 ± 15) Ω Nominal velocity of propagation approx. 67 % Propagation delay ≤ 535 ns/100m Delay skew ≤ 20 ns/100m Test voltage (DC, 1 min) Core/Core and Core/Screen

1000 V

Transfer impedance at 1 MHz ≤ 20 mΩ /m at 10 MHz ≤ 20 mΩ /m at 30 MHz ≤ 30 mΩ /m at 100 MHz ≤ 60 mΩ /m

Nominal transmission characteristics acc. to Category 5e (at 20 °C)

f Attenuation NEXT PS-NEXT ACR PS-ACR ELFEXT PS-ELFEXT Return loss

(MHz) (dB/100m) (dB) (dB) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB)

1.0 1.9 71 68 69.1 66.1 68 65 20

4.0 3.7 62 59 58.3 55.3 56 53 23

10.0 6.0 56 53 50.0 47.0 48 45 25

16.0 7.6 53 50 45.4 42.4 44 41 25

20.0 8.5 51 48 42.5 39.5 42 39 25

31.2 10.7 49 46 38.3 35.3 38 35 24

62.5 15.7 44 41 28.3 25.3 32 29 22

100.0 19.8 41 38 21.2 18.2 28 25 20

125.0 22.3 40 37 17.7 14.7 26 23 19

155.5 24.2 38 35 13.8 10.8 24 21 -

175.0 25.7 37 34 11.3 8.3 23 20 -

200.0 27.5 36 33 8.5 5.5 22 19 -

250.0 29.2 35 32 5.8 2.8 20 17 -

300.0 32.0 34 31 2.0 -1.0 16 13 -

www.DrakaMOG.com

Datacomm12_Jan_07

164

Page 172: Prysmian Draka - Marine & Offshore LV HV Cables

Cat. 7 S/FTP 4x2x0.42 (AWG 27/7) Patch LSHF Shielded 100Ω Data Patchcable ISO/IEC 11801 CAT-7

Standards applied

International ISO/IEC 11801 2nd ed. USA ANSI/EIA/TIA 568A Europe NEN-EN 50173 Cat 7 NEN 11156-5 (IEC 61156) C onstruction NEN-EN 50288-2-1

Application Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10Gbase-T; IEEE 802.5 16MB; ISDN; TPDDI; ATM

Fire Rating Standards Halogen Free IEC 60754-2 Low smoke IEC 61034-1,2 Flame propogation IEC 60332-1

Construction

Conductor Bare copper wire Ø 0.42 mm (AWG27/7) Insulation Foam-skin Polyethylene, Ø 0.98 mm Pair screen Al-laminated plastic foil Twisting 2 cores to the pair Cable lay up 4 pair to the core Overall sheath Copper braid, tinned (ca. 45% coverage) Sheath LSHF, orange

Core identification (in accordance ISO/IEC 11801 2nd edition) Pair 1 white/blue and blue, Pair 2 white/orange and orange, Pair 3 white/green and green, Pair 4 white/brown and brown

Technical Data Prod.number

Draka Comteq Designation No. of cores

and cond.area

Outer diameter

Fire Load

Weight of cable

approx. Copper content

Tensile force

(mm2) (mm) (MJ/km) (kWh/m) (kg/km) (kg/km) (N) CD7677650 S/FTP Cat.7 AWG27/7 PiMF 2x2x0.42 5.9 349 0.097 39 24 100

165

Page 173: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Bending radius ≥ 25 mm without load

≥ 50 mm with load Temperature range, during operation during installation

-20°C upto + 60°C 0°C upto + 50°C

Electrical Properties (at 20°C ± 5°C) DC loop resistance ≤ 340 Ω /km Resistance unbalance ≤ 3% Insulation resistance (500 V) ≥ 2000 MΩ *km Capacitance at 800 Hz nom. 43 nF/km Capacitance unbalance (pair to ground) ≤ 1500 pF/km Characteristic impedance (1-100 MHz) (100 ± 15) Ω (100-250 MHz) (100 ± 18) Ω (250-600 MHz) (100 ± 25) Ω Nominal velocity of propagation approx. 79 % Propagation delay ≤ 427 ns/100m Delay skew ≤ 12 ns/100m Test voltage (DC, 1 min) Core/Core and Core/Screen

1000 V

Transfer impedance at 1 MHz ≤ 25 mΩ /m at 10 MHz ≤ 15 mΩ /m at 30 MHz ≤ 30 mΩ /m

Nominal transmission characteristics acc. to Category 7 (at 20 °C)

f Attenuation NEXT PS-NEXT ACR PS-ACR ELFEXT PS-ELFEXT Return loss

(MHz) (dB/100m) (dB) (dB) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB)

1.0 0.3 90 87 90 80 77 77 23

4.0 0.6 90 87 89 80 77 77 24

10.0 1.0 90 87 89 80 77 77 25

16.0 1.3 90 87 89 76 73 73 25

20.0 1.4 90 87 89 74 71 71 25

31.2 1.8 90 87 88 70 67 67 25

62.5 2.6 90 87 87 64 61 61 23

100.0 3.2 87 84 84 60 57 57 21

125.0 3.6 85 82 81 58 55 55 20

155.5 4.0 84 81 80 56 53 53 19

175.0 4.3 83 80 79 55 52 52 19

200.0 4.6 82 79 77 54 51 51 18

250.0 5.1 81 78 76 52 49 49 18

300.0 5.6 80 77 74 50 47 47 17

450.0 6.9 77 74 70 47 44 44 17

600.0 7.9 75 72 67 44 41 41 17

750.0 8.7 73 70 64 42 39 39 -

900.0 9.7 72 69 62 41 38 38 -

1000.0 10.2 71 68 61 40 37 37 -

www.DrakaMOG.com

Datacomm14_Jan_07

166

Page 174: Prysmian Draka - Marine & Offshore LV HV Cables

Cat. 7 S/FTP 4x2x0.56 (AWG 23) LSHF Shielded 100Ω Data cable ISO/IEC 11801 CAT-7

Standards applied

International ISO/IEC 11801 2nd ed. USA ANSI/EIA/TIA 568A Europe NEN-EN 50173 Cat 7 NEN 11156-5 (IEC 61156) C onstruction NEN-EN 50288-2-1

Application Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10Gbase-T; IEEE 802.5 16MB; ISDN; TPDDI; ATM

Fire Rating Standards Halogen Free IEC 60754-2 Low smoke IEC 61034-1,2 Flame propogation IEC 60332-1

Construction

Conductor Bare copper wire Ø 0.56 mm (AWG23) Insulation Polyethylene, Ø 1.35 mm Pair screen Al-laminated plastic foil Twisting 2 cores to the pair Cable lay up 4 pair to the core Overall sheath Copper braid, tinned (ca. 40% coverage) Sheath LSHF, orange Sheath marking DRAKA COMTEQ S/FTP CAT-7 4x2x0.56

Core identification (in accordance ISO/IEC 11801 2nd edition) Pair 1 white/blue and blue, Pair 2 white/orange and orange, Pair 3 white/green and green, Pair 4 white/brown and brown

Technical Data Prod.number

Draka Comteq Designation No. of cores

and cond.area

Outer diameter

Fire Load

Weight of cable

approx. Copper content

Tensile force

(mm2) (mm) (MJ/km) (kWh/m) (kg/km) (kg/km) (N) CD7679365 S/FTP Cat.7 AWG23 PiMF 2x2x0.56 7.0 590 0.170 65 26 110

167

Page 175: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Bending radius ≥ 40 mm without load

≥ 80 mm with load Temperature range, during operation during installation

-20°C upto + 60°C 0°C upto + 50°C

Electrical Properties (at 20°C ± 5°C) DC loop resistance ≤ 165 Ω /km Resistance unbalance ≤ 2% Insulation resistance (500 V) ≥ 2000 MΩ *km Capacitance at 800 Hz nom. 43 nF/km Capacitance unbalance (pair to ground) ≤ 1500 pF/km Characteristic impedance (1-100 MHz) (100 ± 15) Ω (100-250 MHz) (100 ± 18) Ω (250-600 MHz) (100 ± 25) Ω Nominal velocity of propagation approx. 79 % Propagation delay ≤ 427 ns/100m Delay skew ≤ 12 ns/100m Test voltage (DC, 1 min) Core/Core and Core/Screen

1000 V

Transfer impedance at 1 MHz ≤ 20 mΩ /m at 10 MHz ≤ 30 mΩ /m at 30 MHz ≤ 40 mΩ /m at 100 MHz ≤ 200 mΩ /m

Nominal transmission characteristics acc. to Category 7 (at 20 °C)

f Attenuation NEXT PS-NEXT ACR PS-ACR ELFEXT PS-ELFEXT Return loss

(MHz) (dB/100m) (dB) (dB) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB)

1.0 1.8 100 97 98 95 105 105 -

4.0 3.4 100 97 97 94 105 102 27

10.0 5.4 100 97 95 92 97 94 30

16.0 6.8 100 97 93 90 93 90 30

20.0 7.7 100 97 92 89 91 88 30

31.2 9.6 100 97 90 87 87 84 30

62.5 13.7 100 97 86 83 81 78 30

100.0 17.4 100 97 83 80 77 74 30

125.0 19.5 95 92 75 72 75 72 26

155.5 21.9 94 91 72 69 73 70 26

175.0 23.3 93 90 70 67 72 69 25

200.0 25.0 92 89 67 64 71 68 25

250.0 28.1 90 87 62 59 69 66 24

300.0 30.9 89 86 58 55 67 64 24

450.0 38.3 87 84 48 45 64 61 23

600.0 44.8 85 82 40 37 61 58 22

750.0 52.0 83 80 31 28 59 56 21

900.0 59.4 82 79 23 20 58 55 20

1000.0 63.1 80 77 17 14 57 54 20

www.DrakaMOG.com

Datacomm15_Jan_07

168

Page 176: Prysmian Draka - Marine & Offshore LV HV Cables

D91qfci.e28 Page 1 of 2

Fire resistant QFCI-I/O/RM-JM/- F1

Indoor and outdoor. Fire resistant Flame retardant halogen-free Loose tube

QFCI-I/O/RM-JM/- NEK 606 Code F1

Optical cable for indoor and outdoor use in vital communication and emergency systems that need to be operational during fire. The cable has a patented design that ensures operation for more than 3 hours in fires up to 1000ºC. The cable is halogen free and flame retardant to protect against secondary damage to electronic equipment during and after fire. Outer sheath is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC60811-2-1. The cable is reinforced with a steel wire braiding. The fibres are protected in jelly filled loose tubes stranded around a central strength member to ensure optimum performance and long life. Each fibre and loose tube is colour coded for easy identification during splicing and termination. The outer sheath is marked to show fibre type and cable type.

Fibres in mica wrapped loose tube

Steel strength element

Wrapping

Inner sheath

Filler

Steel wire braiding

Outer sheath

Weight and dimensions

Number of fibres

Number of fibres in each

tube

Number of tubes + fillers

Loose tube diameter

(mm)

Outer diameter

(mm)

Weight

(kg/km)

Heat release

(MJ/km) 4 2 2+4 2.2 13.5 260 1390 8 4 2+4 2.2 13.5 260 1381 12 4 3+3 2.2 13.5 260 1324 24 4 6+0 2.2 13.5 260 1138 48 8 6+0 2.2 13.5 260 1138

Other fibre counts are available on request. Cable properties Tensile strength (IEC 60794-1-2E1) Max tensile load during installation Max tensile load during operation

1500 N500 N

Chemical reistance Mineral oils IRM 902 (IEC60811-2-1) Diesel - IRM 903 (IEC60811-2-1)

- 7 days/23°C - 4 hours/70°C - 7 days/23°C - 4 hours/70°C

Crush (IEC 60794-1-2E3) 3000 N/10cm Fire and smoke classifications Impact (IEC 60794-1-2E4) 30J IEC 60331-25 (750°C, 90 minutes) <1.0 dB excess loss Torsion (IEC 60794-1-2E7) Cable bending Minimum bending diameter Cable bend (IEC 60794-1-2E11)

±1 turn/1m

250 mm<0.1dB/ ±5 turn

Upgraded IEC 60331-25 (1000°C, 3 hours) BP GS 112-2 Clause7.1 IEC 61034 IEC 60332-3-22 (Cat. A) IEC 60332-3-24 (Cat. C)

<1.5 dB excess loss

Temperature window Operation Installation Storage

-40°C to +70°C-10°C to +70°C-40°C to +70°C

IEC 60754-1 IEC 60754-2

www.drakaMOG.com Subject to change without prior notice

169

Page 177: Prysmian Draka - Marine & Offshore LV HV Cables

D91qfci.e28 Page 2 of 2

Fire resistant QFCI-I/O/RM-JM/- F1

www.drakaMOG.com Subject to change without prior notice

Ordering information 9/125 fibre(SMF652D), Black* 50/125 fibre(MMF50HiCap), Black* 62.5/125 fibre(MMF62HiCap), Black*

Part no. Cable code Part no. Cable code Part no. Cable code 694124 G4-62.5/125 QFCI-I/O/RM-JM/- 694144 G8-62.5/125 QFCI-I/O/RM-JM/-

694150 G12-9/125 QFCI-I/O/RM-JM/- 694152 G12-50/125 QFCI-I/O/RM-JM/- 694154 G12-62.5/125 QFCI-I/O/RM-JM/- 694180 G24-9/125 QFCI-I/O/RM-JM/- 694182 G24-50/125 QFCI-I/O/RM-JM/- 694184 G24-62.5/125 QFCI-I/O/RM-JM/- 694139 G48-9/125 QFCI-I/O/RM-JM/- 694169 G48-50/125 QFCI-I/O/RM-JM/- 694189 G48-62.5/125 QFCI-I/O/RM-JM/- *)-Standard colour of outer sheath We reserve the right to alter this specification without notice. Optical fibres

Fibre type 9/125

HiCap 50/125

MaxCap 50/125

HiCap 62.5/125

Reference(DNK) SMF652D MMF50HiCap MMF50MaxCap MMF62HiCap IEC60793-2-50 category B.1.3 A1a A1a.2 A1bIEC11801 classification OS1 and OS2 OM2 OM3 OM1ITU-T type G652.D G651 G651 - Gigabit Ethernet maximum distances SX-serial(850 nm) LX-serial(1310 nm) 5000m

750 m2000 m

900 m 550 m

500 m1000 m

10Gigabit Ethernet maximum distances SX-serial(850 nm) LX-serial(1310 nm) 10000 m

110 m

300 m

65 m

Core diameter See mode field diameter 50 ± 2.5 μm 50 ± 2.5 μm 62.5 ± 2.5 μmMode field diameter 1310 nm 9.2 ± 0.4 μm

1550 nm 10.3 ± 0.5 μm

Cladding diam. loose tube 125 ± 0.7 μm 125 ± 2.0 μm 125 ± 2.0 μm 125 ± 2.0 μmCladding diam. tight buffer 125 ± 0.7 μm 125 ± 2.0 μm 125 ± 2.0 μm 125 ± 2.0 μmPrimary coating diameter (nominal)

242 ± 7 μm 250 μm 250 μm 250 μm

Attenuation (Typical values) 850 nm 1300 nm 1310 nm 1550 nm

0.33 – 0.37 dB/km 0.19 – 0.23dB/km

≤ 2.5 dB/km ≤ 0.7 dB/km

≤ 2.5 dB/km ≤ 0.7 dB/km

≤ 3.0 dB/km ≤ 0.7 dB/km

Attenuation (Maximum values) 850 nm 1300 nm 1310 nm 1550 nm

≤ 0.40 dB/km ≤ 0.25 dB/km

≤ 2.7 dB/km ≤ 0.8 dB/km

≤ 2.7 dB/km ≤ 0.9 dB/km

≤ 3.2 dB/km ≤ 1.0 dB/km

Bandwidth(OFL*) 850 nm 1300 nm

>600 MHz⋅km>1200 MHz⋅km

>1500 MHz⋅km

>500 MHz⋅km >200 MHz⋅km>600 MHz⋅km

Chromatic Dispersion 1285-1330 nm 1550 nm

≤ 3 ps/nm⋅km≤ 18 ps/nm⋅km

Polarization Mode Disp. PMD Link Design Value ** Max. Individual Fibre

≤ 0.06 √km≤ 0.1 √km

Numerical aperture 0.13 ( nominal) 0.200 ± 0.015 0.200 ± 0.015 0.275 ± 0.015Minimum permanent bending diameter 50 mm 50 mm

50 mm 50 mm

* Over Filled Launch methode(OFL). Modal Bandwidth in accordance with IEC60793-1-41. ** According to IEC 60794-3, Ed.3 (Q=0.01%) Other fibre types and qualities are available on request.

Rev: 09/07

170

Page 178: Prysmian Draka - Marine & Offshore LV HV Cables

S611T MARINE FIBER OPTIC CABLE Fiber Optic Cable - Tight buffer construction

Standards applied

Construction IEC 60794-1,2,3 P erformance requir. IEEE 802.3z (Gigabit Ethernet)

Application The Draka S611T series of Marine and Offshore fiber optic cables is designed especially for the harsh environments of commercial marine vessels, oil platforms and other similar applications. Draka S611T low smoke/zero halogen, flame retardant cables offer the versatility and ease of use of our other offshore cables in a construction suited for marine applications. They are complaint with the latest IEC requirements. S611T cables meet the requirements of IEC 60793-1 and IEC 60793-2 specifications, are encapsulated in all dielectric, tight buffered construction, individually reinforced with aramid yarns and jacketed (breakout style). The break-out components are cabled around a central member providing additional tensile strength to the entire construction. The thermoplastic low smoke/ zero halogen jacketing system offers good resistance to chemicals, fluids, fungus and abrasion. This product is also available in an armoured version.

Fire Rating Standards Halogen Free IEC 60754-1,2 Low smoke IEC 61034-1,2 Flame propagation IEC 60332-1-25 Toxicity NES 713 Fire retardant IEC 60332-3-22 (Cat.A) IEEE 1202 Approvals Det Norske Veritas (DNV)

Certificate E-7154

American Bureau of Shipping (ABS)

Certificate 01-NY6461-X

Lloyd’s Registry of Shipping (LR)

Certificate 00/00157E1

Construction

Fibre Possible fibre types; 62.5 µm MULTIMODE, 50 µm MULTIMODE, 200 µm MULTIMODE or 8.3 µm SIGNLEMODE.

Cladding Multimode or singlemode fibres with an easily-strippable 900 µm tight buffered colored per TIA/EIA 598.

Cable lay up Tight buffered tubes stranded around a central strength member of dielectric material (epoxy/fibreglass rod).

Tube filling Subunit strength member of aramid yarn. Tube LSHF, colored acc. to TIA/EIA 598. Overall wrapping PET-foil Sheath LSHF, black Fiber performance

171

Page 179: Prysmian Draka - Marine & Offshore LV HV Cables

62.5µm MULTIMODE

50µm MULTIMODE

200µm MULTIMODE

8.3µm SINGLEMODE

Fiber Designation 62X 50H 200S 010X Application specs. IEC 60793-2 Type

A1b ITU G.651 & IEC

60793-2 Type A1aITU G.651 & IEC

60793-2 Type A1a ITU G.652 C & D

req. & IEC 60793-2 Type B1.1

Fiber type Graded Index Graded Index Step Index Matched Clad Core diameter 62.5µm + 2.5µm 50µm + 2.5µm 200µm + 5µm 8.3µm Nominal Cladding diameter 125µm + 1µm 125µm + 1µm 230µm + 10µm 125µm + 1µm Coating diameter 242µm + 7µm 242µm + 7µm 500µm + 30µm 242µm + 7µm Buffer diameter 900µm + 50µm 900µm + 50µm 900µm + 50µm 900µm + 50µm Numerical aperture 0.275 + 0.015 0.200 + 0.015 0.37 nominal N/A Mode field diameter N/A N/A N/A 9.1µm + 0.4µm Attenuation 820 Nm N/A N/A < 12.0 dB/km N/A 850 Nm < 3.5 dB/km < 3.5 dB/km N/A N/A 1300 Nm < 1.0 dB/km < 1.0 dB/km N/A < 0.70 dB/km 1550 Nm N/A N/A N/A < 0.70 dB/km Bandwidth 820 Nm N/A N/A < 20 MHz/km N/A 850 Nm < 200 MHz/km < 500 MHz/km N/A N/A 1300 Nm < 500 MHz/km < 500 MHz/km N/A N/A Dispersion 1285-1330 Nm N/A N/A N/A < 3.0 ps/nm.km 1550 Nm N/A N/A N/A < 18 ps/nm.km Proof test 100,000 psi 100,000 psi 150,000 psi 100,000 psi Mechanical Properties Temperature range, during installation -10°C to +60°C during operation -20°C to +80°C storage -40°C to +80°C Crush (IEC 60794-1-2E3) 3000 N/10cm Impact (IEC 60794-1-2E4) 20 impacts, 5J Torsion (IEC 60794-1-2E7) + 1 turn/2 m, 100 cycles Cable bending, Cable bend

(IEC 60794-1-2E11) < 0.1 dB / + 6 turns

Technical Data Prod.number Draka

Comteq Number of

fibers INSTALLATION OPERATING Outer diameter Weight of cable approx.

Pull strength Bend radius Tension Bend radius (N) (mm) (N) (mm) (mm) (N)

S611T-02R-xxy 2 600 12.8 200 6.4 6.4 45 S611T-04-xxy 4 600 14.6 200 7.3 7.3 51 S611T-06-xxy 6 600 17.0 200 8.5 8.5 71 S611T-08-xxy 8 600 19.4 200 9.7 9.7 93 S611T-10-xxy 10 600 22.0 200 11.0 11.0 119 S611T-12-xxy 12 600 24.4 200 12.2 12.2 149 S611T-16-xxy 16 2700 25.7 600 12.8 12.8 150 S611T-18-xxy 18 2700 25.7 600 12.8 12.8 148 S611T-24-xxy 24 2700 29.6 600 14.8 14.8 356 S611T-36-xxy 36 2700 34.0 600 17.0 17.0 484 S611T-48-xxy 48 2700 46.0 600 23.1 23.0 600

Replace the xxy with the Fiber designation in the fiber performance table above NOTE: Fibers are not suitable for F07 crimp and cleave connector Information is subject to change without notice. Consult factory for a variety of alternate constructions for specific applications

www.DrakaMOG.com

Datacomm19_Jan_07 172

Page 180: Prysmian Draka - Marine & Offshore LV HV Cables

S670T ARMOURED MARINE FIBER OPTIC CABLE Fiber Optic Cable – Armoured tight buffer construction

Standards applied

Construction IEC 60794-1,2,3 P erformance requir. IEEE 802.3z (Gigabit Ethernet)

Application The Draka S670T series of Marine and Offshore fiber optic cables is designed especially for the harsh environments of commercial marine vessels, oil platforms and other similar applications. Draka S670T low smoke/zero halogen, flame retardant cables offer the versatility and ease of use of our other offshore cables in a construction suited for marine applications. They are complaint with the latest IEC requirements. S670T cables meet the requirements of IEC 60793-1 and IEC 60793-2 specifications, are encapsulated in all dielectric, tight buffered construction, individually reinforced with aramid yarns and jacketed (breakout style). The thermoplastic low smoke/ zero halogen jacketing system offers good resistance to chemicals, fluids, fungus and abrasion. This product is also available in a non-armoured ersion. v

Fire Rating Standards Halogen Free IEC 60754-1,2 Low smoke IEC 61034-1,2 Flame propagation IEC 60332-1-25 Toxicity NES 713 Fire retardant IEC 60332-3-22 (Cat.A) IEEE 1202 Approvals Det Norske Veritas (DNV)

Certificate E-7155

American Bureau of Shipping (ABS)

Certificate 01-NY6461-X

Lloyd’s Registry of Shipping (LR)

Certificate 00/00157E1

Construction

Fibre Possible fibre types; 62.5 µm MULTIMODE, 50 µm MULTIMODE, 200 µm MULTIMODE or 8.3 µm SIGNLEMODE.

Cladding Multimode or singlemode fibres with an easily-strippable 900 µm tight buffered colored per TIA/EIA 598.

Cable lay up Tight buffered tubes stranded around a central strength member of dielectric material (epoxy/fibreglass rod).

Tube filling Subunit strength member of aramid yarn. Tube LSHF, colored acc. to TIA/EIA 598. Overall wrapping PET-foil under a filling of aramid yarns Inner sheath LSHF, black Overall screen Bare bronze wire braiding in acc. with IEEE 1580(2001) Outer sheath LSHF, black

173

Page 181: Prysmian Draka - Marine & Offshore LV HV Cables

Fiber performance

62.5µm MULTIMODE

50µm MULTIMODE

200µm MULTIMODE

8.3µm SINGLEMODE

Fiber Designation 62X 50H 200S 010X Application specs. IEC 60793-2 Type

A1b ITU G.651 & IEC

60793-2 Type A1aITU G.651 & IEC

60793-2 Type A1a ITU G.652 C & D

req. & IEC 60793-2 Type B1.1

Fiber type Graded Index Graded Index Step Index Matched Clad Core diameter 62.5µm + 2.5µm 50µm + 2.5µm 200µm + 5µm 8.3µm Nominal Cladding diameter 125µm + 1µm 125µm + 1µm 230µm + 10µm 125µm + 1µm Coating diameter 242µm + 7µm 242µm + 7µm 500µm + 30µm 242µm + 7µm Buffer diameter 900µm + 50µm 900µm + 50µm 900µm + 50µm 900µm + 50µm Numerical aperture 0.275 + 0.015 0.200 + 0.015 0.37 nominal N/A Mode field diameter N/A N/A N/A 9.1µm + 0.4µm Attenuation 820 Nm N/A N/A < 12.0 dB/km N/A 850 Nm < 3.5 dB/km < 3.5 dB/km N/A N/A 1300 Nm < 1.0 dB/km < 1.0 dB/km N/A < 0.70 dB/km 1550 Nm N/A N/A N/A < 0.70 dB/km Bandwidth 820 Nm N/A N/A < 20 MHz/km N/A 850 Nm < 200 MHz/km < 500 MHz/km N/A N/A 1300 Nm < 500 MHz/km < 500 MHz/km N/A N/A Dispersion 1285-1330 Nm N/A N/A N/A < 3.0 ps/nm.km 1550 Nm N/A N/A N/A < 18 ps/nm.km Proof test 100,000 psi 100,000 psi 150,000 psi 100,000 psi Mechanical Properties Temperature range, during installation -10°C to +60°C during operation -20°C to +80°C storage -40°C to +80°C Crush (IEC 60794-1-2E3) 3000 N/10cm Impact (IEC 60794-1-2E4) 20 impacts, 5J Torsion (IEC 60794-1-2E7) + 1 turn/2 m, 100 cycles Cable bending, Cable bend

(IEC 60794-1-2E11) < 0.1 dB / + 6 turns

Technical Data Prod.number Draka

Comteq Number of

fibers INSTALLATION OPERATING Outer diameter Weight of cable approx.

Pull strength Bend radius Tension Bend radius (N) (mm) (N) (mm) (mm) (N)

S670T-02R-xxy 2 600 21.4 200 10.7 10.7 223 S670T-04-xxy 4 600 23.0 200 11.5 11.5 230 S670T-06-xxy 6 600 25.6 200 12.8 12.8 260 S670T-08-xxy 8 600 28.0 200 14.0 14.0 278 S670T-10-xxy 10 600 30.6 200 15.3 15.3 310 S670T-12-xxy 12 600 33.0 200 16.5 16.5 381 S670T-16-xxy 16 2700 34.4 600 17.2 17.2 408 S670T-18-xxy 18 2700 34.4 600 17.2 17.2 402 S670T-24-xxy 24 2700 38.0 600 19.0 19.0 484 S670T-36-xxy 36 2700 43.7 600 21.8 21.8 566 S670T-48-xxy 48 2700 58.9 600 21.8 28.9 1083

Replace the xxy with the Fiber designation in the fiber performance table above NOTE: Fibers are not suitable for F07 crimp and cleave connector Information is subject to change without notice. Consult factory for a variety of alternate constructions for specific applications

www.DrakaMOG.com

Datacomm20_Jan_07

174

Page 182: Prysmian Draka - Marine & Offshore LV HV Cables

Standards applied

Germany DIN 19245-3 E urope EN 50170-Vol.2 PROFIBUS

Application As a bus cable for fixed installation on board ships and offshore units in all locations and on open decks. The cable is not suitable for continues use in water.

Fire Rating Standards Halogen Free IEC 60754-2 Low smoke IEC 61031 Ozone resistance IEC 61031 Fire retardant IEC 60332-3-24 (cat. C)

SIENOPYR-FR-PROFIBUS M-02Y(St)CHX 100V Profibus cable for ships and offshore units

Construction

Conductor Stranded bare copper wire 0.35 mm² (AWG22/7) Insulation Foam-skin Polyethylene (Foam-PE) Core identification a – core: red, b – core: green Cable lay up Laying of the cores with two dummies Overall sheath PET-foil Overall screen Laminated aluminium-foil under a copper braid, tinned Inner sheath FRNC, Ø 8.0 mm Outer sheath FRNC, black Ø 10.8 mm Sheath marking year – SIENOPYR-FR-PROFIBUS M-02Y(St)CHX 1x2x0,35 mm² 100V, 150Ω

Technical Data Prod.number

Draka Comteq Designation No. of cores

and cond.area

Outer diameter

Weight of cable approx.

Copper content Tensile force

(mm2) (mm) (kg/km) (kg/km) (N) CD7677650 SIENOPYR-FR-PROFIBUS 1x2x0.35 10.8 70

175

Page 183: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Bending radius ≥ 100 mm without load

≥ 200 mm with load Temperature range, during operation -40°C upto + 80°C during installation -10°C upto + 50°C Resistance to chemicals Diesel fuel to DIN VDE 51601 (test to VG 95218 part 2) ASTM oil No. 2 to DIN 53521 Oils, NATO code 0-178, BW-TL 9150-0031/2 to VG 95214 part 4 Hydraulic fluids, NATO code H-515, BW-TL 9150-0020 to VG

95214 part 4 Solvent cleansing agents, BW-TL 6850-0017 to VG 95214 part 4 De-ionized water to VG 95214 part 4 De-ionized water with 3,5% NaCl.

Electrical Properties (at 20°C ± 5°C) DC loop resistance ≤ 110 Ω /km Mutual capacitance (at 800 Hz) ≤ 30 nF/km Characteristic impedance (at 9.6 kHz) (250 ± 25) Ω . (at 38.4 kHz) (185 ± 18.5) Ω . (3-20 MHz) (150 ± 15) Ω Insultion resistance > 16 GΩ.km Nominal voltage 110 Veff

Nominal transmission characteristics (at 20 °C)

f Attenuation

(MHz) (dB/100m)

0.0096 0.3

0.0384 0.5

4.0 2.2

16.0 4.5

www.DrakaMOG.com

Datacomm01_Jan_07

176

Page 184: Prysmian Draka - Marine & Offshore LV HV Cables

ToughCat™ S/STP 4x2x0,6 (AWG 24/7) LSHF-FR Shielded 100Ω Data cable ISO/IEC 11801 CAT-5e

Standards applied

International ISO/IEC 11801 2nd ed. USA ANSI/EIA/TIA 568A Europe NEN-EN 50173 Cat 5e NEN 11156-5 (IEC 61156) Construction NEN-EN 50288-2-1 O il-resistance CEI 20.34 4h 70C IRM902

Application This Cat.5e S/STP cable is meant for use as horizontal cable in tougher electrical and has stranded copper conductors arranged in individually foil screened twisted pairs. All four pairshave a common braid. The susceptibility of noise is very low because of excellent shielding performance. Because of this, the cable can also be used in Class F (Cat.7) installations up to 70 m.

ermanent links. P

Fire Rating Standards Halogen Free IEC 60754-2 Low smoke IEC 61034-1,2 Flame propogation IEC 60332-1 Fire retardant IEC 60332-3-24 (cat. C) Specifications Det Norske Veritas (DNV) Lloyd’s Registar (LR) Germanischer Lloyd’s (GL)

Construction

Conductor Bare copper wire Ø 0.60 mm (AWG24/7) Insulation Polyethylene, Ø 1.4 mm Twisting 2 cores to the pair Pair screen 4 pairs Cable lay up Al-laminated plastic foil around each pair Overall sheath Copper braid, tinned Sheath Oil resistant, fire retardant and halogen free LSHF-FR, grey RAL 7035

Core identification (in accordance ISO/IEC 11801 2nd edition) Pair 1 white/blue and blue, Pair 2 white/orange and orange, Pair 3 white/green and green, Pair 4 white/brown and brown

Technical Data Prod.number

Draka Comteq Designation No. of cores

and cond.area

Outer diameter

Fire Load

Weight of cable

approx. Copper content

Tensile force

(mm2) (mm) (MJ/km) (kWh/m) (kg/km) (kg/km) (N) CNS792621 ToughCat S-STP LSHF-FR 2x2x0.60 7.8 462 0.128 44 33 100

177

Page 185: Prysmian Draka - Marine & Offshore LV HV Cables

Mechanical Properties Bending radius ≥ 25 mm without load

≥ 50 mm with load Temperature range, during operation during installation

-20°C upto + 85°C 0°C upto + 50°C

Electrical Properties (at 20°C ± 5°C) DC loop resistance ≤ 158 Ω /km Resistance unbalance ≤ 2% Insulation resistance (500 V) ≥ 2000 MΩ *km Capacitance at 800 Hz nom. 43 nF/km Capacitance unbalance (pair to ground) ≤ 1500 pF/km Characteristic impedance (1-100 MHz) (100 ± 15) Ω (100-250 MHz) (100 ± 18) Ω Nominal velocity of propagation approx. 75 % Propagation delay ≤ 450 ns/100m Delay skew ≤ 15 ns/100m Test voltage (DC, 1 min) Core/Core and Core/Screen

1000 V

Transfer impedance at 1 MHz ≤ 10 mΩ /m at 10 MHz ≤ 8 mΩ /m at 30 MHz ≤ 10 mΩ /m

Nominal transmission characteristics acc. to Category 7 (at 20 °C)

f Attenuation NEXT PS-ACR PS-NEXT ELFEXT PS-ELFEXT Return loss

(MHz) (dB/100m) (dB) (dB) (dB/100m) (dB/100m) (dB/100m) (dB)

1.0 2.1 90 85 87 85 82 23

4.0 4.0 90 83 87 85 82 24

10.0 6.3 90 81 87 79 76 25

16.0 8.0 90 79 87 75 72 25

20.0 9.0 90 78 87 73 70 25

31.2 11.4 90 76 87 69 66 25

62.5 16.5 86 67 83 63 60 23

100.0 21.3 83 59 80 59 56 21

125.0 24.2 81 54 78 57 54 20

200.0 31.5 78 44 75 53 50 18

250.0 35.8 77 38 74 51 48 18

400.0 47.1 73 23 70 47 44 17

600.0 60.1 71 8 68 44 41 17

www.DrakaMOG.com

Datacomm13_Jan_07 178

Page 186: Prysmian Draka - Marine & Offshore LV HV Cables

14

Application:

Unarmored power and control cables 0.6/1 kV with specialproperties for electrical installations in ships and offshoreunits. Temperature Class 85 °C, Flame Retardant (IEC 60332-3 category “A”, “A/F”), Low Smoke, HalogenFree, Low Toxicity. Suitable for application in cold climateareas required to pass cold bend and cold impact testingat –40 °C and –35 °C, respectively.

Construction:

Generally according to IEC 60092-3 0.6/1 kV

Conductors: stranded bare annealed copper, IEC 60228, (Class 2)sizes 1 - 300 mm2

Insulation: cross linked polyethylene (XLPE/HF XLPE) according to IEC 60092-3,IEC 60092-351 and IEEE Std 45

Assembly: cores cabled togetherFiller: halogen free filling compoundSheathing: halogen free, flame retardant

(SHF1, IEC 60092-359); all sheath andjacketing materials shall pass tearresistance testing to 35 lbs/in(6.4 N/mm)

Sheathing color: gray (other colors are available on request)

Identification of the cores:

1 core black2 cores black, blue3 cores black, blue, brown4 cores black, blue, brown, green/yellow5 cores and up: black, numbered

Special cable properties:

Fire propagation: IEC 60332-3 category “A”, “A/F”Smoke: IEC 61034-1/2, MIL-C-24643A

(par. 4.7.27) and NES 711Acidity: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.25)Halogen content: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.26)Toxicity index: NES 713Cold properties: cold bend (–40 °C) and cold impact

(–35 °C) according to CAN/CSA-C22.2No. 0.3-Dec. ’92

Power and control cablesHXXM EEP 0.6/1 kV IEC 60092-3

Class 2 conductors

Opmaak Control Cables 27-07-2001 15:16 Pagina 14

179

Page 187: Prysmian Draka - Marine & Offshore LV HV Cables

General data for HXXM EEP 0.6/1 kV EEP IEC 60092-3Class 2 conductors

number of number of nominal nominal nominal nominal minimum approxi- approxi- conductor conductorcores and wires in conductor core outer outer bending mate mate resistance resistancenominal cross conductor diameter diameter diameter diameter radius weight weight at 20 °C DC at 20 °C DCsectional area class 2(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (lbs/M’) (kg/km) (Ω/M’) (Ω/km)

1 x 1.5 7 1.6 3.4 0.220 5.6 28 29 43 3.7 12.11 x 2.5 7 2.0 3.9 0.236 6.0 30 37 55 2.26 7.411 x 4 7 2.5 4.6 0.268 6.8 34 50 75 1.41 4.611 x 6 7 3.1 5.2 0.287 7.3 37 63 94 0.94 3.081 x 10 7 4.0 6.2 0.339 8.6 43 101 150 0.56 1.831 x 16 7 5.0 7.5 0.386 9.8 49 141 210 0.35 1.151 x 25 7 6.3 9.0 0.457 11.6 58 215 320 0.222 0.7271 x 35 19 7.0 9.7 0.484 12.3 74 276 410 0.160 0.5241 x 50 19 8.1 11.0 0.642 16.3 98 437 650 0.118 0.3871 x 70 19 9.7 13.0 0.728 18.5 111 591 880 0.082 0.2681 x 95 19 11.4 15.0 0.811 20.6 124 779 1,160 0.059 0.1931 x 120 37 13.9 17.7 0.929 23.6 142 974 1,450 0.047 0.1531 x 150 37 15.5 19.5 1.028 26.1 157 1,189 1,770 0.038 0.1241 x 185 37 17.3 21.5 1.106 28.1 169 1,445 2,150 0.0302 0.09911 x 240 61 19.9 24.5 1.248 31.7 190 1.881 2,800 0.0230 0.07541 x 300 61 22.2 27.3 1.366 34.7 208 2.298 3,420 0.0183 0.0601

2 x 1.5 7 1.6 3.4 0.394 10.0 50 101 150 3.7 12.12 x 2.5 7 2.0 3.9 0.437 11.1 56 128 190 2.26 7.412 x 4 7 2.5 4.6 0.500 12.7 76 175 260 1.41 4.612 x 6 7 3.1 5.2 0.563 14.3 86 228 340 0.94 3.082 x 10 7 4.0 6.2 0.661 16.8 101 329 490 0.56 1.832 x 16 7 5.0 7.5 0.783 19.9 119 484 720 0.35 1.152 x 25 7 6.3 9.0 0.909 23.1 139 706 1,050 0.222 0.7272 x 35 19 7.0 9.7 0.969 24.6 148 874 1,300 0.160 0.5242 x 50 19 8.1 11.0 1.079 27.4 164 1,109 1,650 0.118 0.3872 x 70 19 9.7 13.0 1.280 32.5 195 1,546 2,300 0.082 0.2682 x 95 19 11.4 15.0 1.445 36.7 220 2,083 3,100 0.059 0.193

3 x 1.5 7 1.6 3.4 0.417 10.6 53 114 170 3.7 12.13 x 2.5 7 2.0 3.9 0.461 11.7 59 141 210 2.26 7.413 x 4 7 2.5 4.6 0.528 13.4 80 195 290 1.41 4.613 x 6 7 3.1 5.2 0.594 15.1 91 262 390 0.94 3.083 x 10 7 4.0 6.2 0.701 17.8 107 396 590 0.56 1.833 x 16 7 5.0 7.5 0.815 20.7 124 564 840 0.35 1.153 x 25 7 6.3 9.0 0.953 24.2 145 840 1,250 0.222 0.7273 x 35 19 7.0 9.7 1.039 26.4 158 1,075 1,600 0.160 0.5243 x 50 19 8.1 11.0 1.165 29.6 178 1,411 2,100 0.118 0.3873 x 70 19 9.7 13.0 1.354 34.4 206 1,915 2,850 0.082 0.2683 x 95 19 11.4 15.0 1.547 39.3 236 2,621 3,900 0.059 0.1933 x 120 37 13.9 17.7 1.791 45.5 273 3,326 4,950 0.047 0.1533 x 150 37 15.5 19.5 1.976 50.2 301 4,099 6,100 0.038 0.1243 x 185 37 17.3 21.5 2.165 55.0 330 5,006 7,450 0.0302 0.09913 x 240 61 19.9 24.5 2.449 62.2 373 6,518 9,700 0.0230 0.0754

4 x 1.5 7 1.6 3.4 0.461 11.7 59 134 200 3.7 12.14 x 2.5 7 2.0 3.9 0.504 12.8 77 168 250 2.26 7.414 x 4 7 2.5 4.6 0.583 14.8 89 242 360 1.41 4.614 x 6 7 3.1 5.2 0.634 16.1 97 302 450 0.94 3.084 x 10 7 4.0 6.2 0.772 19.6 118 484 720 0.56 1.834 x 16 7 5.0 7.5 0.902 22.9 137 706 1,050 0.35 1.154 x 25 7 6.3 9.0 1.051 26.7 160 1,008 1,500 0.222 0.7274 x 35 19 7.0 9.7 1.130 28.7 172 1,310 1,950 0.160 0.5244 x 50 19 8.1 11.0 1.287 32.7 196 1,747 2,600 0.118 0.3874 x 70 19 9.7 13.0 1.504 38.2 229 2,385 3,550 0.082 0.2684 x 95 19 11.4 15.0 1.717 43.6 262 3,293 4,900 0.059 0.1934 x 120 37 13.9 17.7 1.992 50.6 304 4,166 6,200 0.047 0.1534 x 150 37 15.5 19.5 2.189 55.6 334 5,107 7,600 0.038 0.124

5 x 1.5 7 1.6 3.4 0.504 12.8 77 148 220 3.7 12.15 x 2.5 7 2.0 3.9 0.555 14.1 85 202 300 2.26 7.415 x 4 7 2.5 4.6 0.634 16.1 97 282 420 1.41 4.615 x 25 7 6.3 9.0 1.185 30.1 181 1,243 1,850 0.222 0.727

24 x 1 7 1.3 3.1 0.858 21.8 131 349 520 5.5 18.1

7 x 1.5 7 1.6 3.4 0.516 13.1 79 148 220 3.7 12.124 x 1.5 7 1.6 3.4 0.949 24.1 145 470 700 3.7 12.137 x 1.5 7 1.6 3.4 1.102 28.0 168 672 1,000 3.7 12.1

7 x 2.5 7 2.0 3.9 0.575 14.6 88 202 300 2.26 7.4110 x 2.5 7 2.0 3.9 0.732 18.6 112 289 430 2.26 7.4120 x 2.5 7 2.0 3.9 0.953 24.2 145 531 790 2.26 7.4124 x 2.5 7 2.0 3.9 1.059 26.9 161 632 940 2.26 7.4130 x 2.5 7 2.0 3.9 1.130 28.7 172 773 1,150 2.26 7.4136 x 2.5 7 2.0 3.9 1.236 31.4 188 941 1,400 2.26 7.41

15

Opmaak Control Cables 27-07-2001 15:16 Pagina 15

180

Page 188: Prysmian Draka - Marine & Offshore LV HV Cables

16

Application:

Unarmored power and control cables 0.6/1 kV with specialproperties for electrical installations in ships and offshoreunits.Temperature Class 85 °C, Flame Retardant (IEC 60332-3category “A”, “A/F”), Low Smoke, Halogen Free, LowToxicity. Suitable for application in cold climate areas required to pass cold bend and cold impact testing at–40 °C and –35 °C, respectively.

Construction:

Generally according to IEC 60092-3 0.6/1 kV

Conductors: flexible bare annealed copper, IEC 60228, (Class 5)sizes 1 - 300 mm2

Insulation: cross linked polyethylene (XLPE/HF XLPE) according to IEC 60092-3,IEC 60092-351 and IEEE Std 45

Assembly: cores cabled togetherFiller: halogen free filling compoundSheathing: halogen free, flame retardant

(SHF1, IEC 60092-359); all sheath andjacketing materials shall pass tearresistance testing to 35 lbs/in(6.4 N/mm)

Sheathing color: gray (other colors are available on request)

Identification of the cores:

1 core black2 cores black, blue3 cores black, blue, brown4 cores black, blue, brown, green/yellow

Special cable properties:

Fire propagation: IEC 60332-3 category “A”, “A/F”Smoke: IEC 61034-1/2, MIL-C-24643A

(par. 4.7.27) and NES 711Acidity: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.25)Halogen content: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.26)Toxicity index: NES 713Cold properties: cold bend (–40 °C) and cold impact

(–35 °C) according to CAN/CSA-C22.2No. 0.3-Dec. ’92

Power and control cablesHXXM EEP 0.6/1 kV IEC 60092-3

Class 5 conductors

Opmaak Control Cables 27-07-2001 15:16 Pagina 16

181

Page 189: Prysmian Draka - Marine & Offshore LV HV Cables

General data for HXXM EEP 0.6/1 kV IEC 60092-3Class 5 conductors

number of number of nominal nominal nominal nominal minimum approxi- approxi- conductor conductorcores and wires in conductor core outer outer bending mate mate resistance resistancenominal cross conductor diameter diameter diameter diameter radius weight weight at 20 °C DC at 20 °C DCsectional area class 5(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (lbs/M’) (kg/km) (Ω/M’) (Ω/km)

1 x 35 266 8.2 11.0 0.535 13.6 82 286 425 0.169 0.5441 x 50 380 9.8 12.8 0.713 18.1 109 474 705 0.118 0.3861 x 70 330 11.6 15.1 0.811 20.6 124 638 950 0.083 0.2721 x 95 437 13.1 16.8 0.886 22.5 135 806 1,200 0.063 0.2061 x 120 562 15.4 19.2 0.988 25.1 151 1,008 1,500 0.049 0.1611 x 150 703 17.1 21.2 1.094 27.8 167 1,257 1,870 0.039 0.1291 x 185 851 18.5 22.8 1.165 29.6 178 1,478 2,200 0.032 0.1061 x 240 1,117 21.3 26.0 1.307 33.2 199 1.951 2,850 0.0244 0.08011 x 300 1,384 23.7 28.8 1.429 36.3 218 2.318 3,450 0.0195 0.0641

2 x 35 266 8.2 11.0 1.067 27.1 163 941 1,400 0.169 0.5542 x 50 380 9.8 12.8 1.228 31.2 187 1,277 1,900 0.118 0.3862 x 70 330 11.6 15.1 1.437 36.5 219 1,767 2,630 0.083 0.2722 x 95 437 13.1 16.8 1.587 40.3 242 2,231 3,320 0.063 0.206

3 x 35 266 8.2 11.0 1.154 29.3 176 1,159 1,725 0.169 0.5543 x 50 380 9.8 12.8 1.315 33.4 200 1,566 2,330 0.118 0.3863 x 70 330 11.6 15.1 1.543 39.2 235 2,184 3,250 0.083 0.2723 x 95 437 13.1 16.8 1.701 43.2 259 2,779 4,135 0.063 0.2063 x 120 562 15.4 19.2 1.929 49.0 294 3,548 5,280 0.049 0.1613 x 150 703 17.1 21.2 2.122 53.9 323 4,368 6,500 0.039 0.1293 x 185 851 18.5 22.8 2.272 57.7 346 5,157 7,675 0.032 0.1063 x 240 1,117 21.3 26.0 2.579 65.5 393 6,703 9,975 0.0244 0.0801

4 x 35 266 8.2 11.0 1.272 32.3 194 1,428 2,125 0.169 0.5544 x 50 380 9.8 12.8 1.457 37.0 222 1,939 2,885 0.118 0.3864 x 70 330 11.6 15.1 1.709 43.4 260 2,715 4,040 0.083 0.2724 x 95 437 13.1 16.8 1.890 48.0 288 3,464 5,155 0.063 0.2064 x 120 562 15.4 19.2 2.146 54.5 327 4,428 6,590 0.049 0.1614 x 150 703 17.1 21.2 2.354 59.8 359 5,433 8,085 0.039 0.129

17

Opmaak Control Cables 27-07-2001 15:16 Pagina 17

182

Page 190: Prysmian Draka - Marine & Offshore LV HV Cables

General data for HXXM-FR EEP 0.6/1 kV IEC 60092-3Class 2 conductors

number of number of nominal nominal nominal nominal approxi approxcores and wires in conductor core diameter diameter mate weightnominal cross conductor diameter diameter over over weightsectional area class 2 sheath sheath(n x mm2) (n) (mm) (mm) (inches) (mm) (lbs/M’) (kg/km)

1 x 1.5 7 1.6 4.3 0.252 6.4 35 521 x 2.5 7 2.0 4.7 0.272 6.9 43 641 x 4 7 2.5 5.5 0.299 7.6 56 841 x 6 7 3.1 6.0 0.319 8.1 71 1051 x 10 7 4.0 7.1 0.370 9.4 107 1591 x 16 7 5.0 8.3 0.421 10.7 151 2241 x 25 7 6.3 9.8 0.492 12.5 223 3321 x 35 19 7.0 10.6 0.520 13.2 287 4271 x 50 19 8.1 11.9 0.677 17.2 455 6771 x 70 19 9.7 13.9 0.764 19.4 612 9111 x 95 19 11.4 15.8 0.846 21.5 804 11971 x 120 37 13.9 18.6 0.961 24.4 986 14671 x 150 37 15.5 20.3 1.059 26.9 1218 18121 x 185 37 17.3 22.3 1.150 29.2 1481 22041 x 240 61 19.9 25.4 1.283 32.6 1906 28371 x 300 61 22.2 28.1 1.398 35.5 2328 3464

2 x 1.5 7 1.6 4.3 0.461 11.7 126 1872 x 2.5 7 2.0 4.7 0.508 12.9 158 2352 x 4 7 2.5 5.5 0.579 14.7 214 3182 x 6 7 3.1 6.0 0.630 16.0 264 3932 x 10 7 4.0 7.1 0.728 18.5 375 5582 x 16 7 5.0 8.3 0.850 21.6 534 7942 x 25 7 6.3 9.8 0.976 24.8 747 11122 x 35 19 7.0 10.6 1.035 26.3 917 13642 x 50 19 8.1 11.9 1.157 29.4 1184 17622 x 70 19 9.7 13.9 1.346 34.2 1646 24502 x 95 19 11.4 15.8 1.512 38.4 2160 3215

3 x 1.5 7 1.6 4.3 0.492 12.5 141 2103 x 2.5 7 2.0 4.7 0.535 13.6 176 2623 x 4 7 2.5 5.5 0.614 15.6 243 3613 x 6 7 3.1 6.0 0.669 17.0 304 4533 x 10 7 4.0 7.1 0.772 19.6 436 6493 x 16 7 5.0 8.3 0.886 22.5 615 9153 x 25 7 6.3 9.8 1.039 26.4 899 13383 x 35 19 7.0 10.6 1.110 28.2 1136 16913 x 50 19 8.1 11.9 1.240 31.5 1478 22003 x 70 19 9.7 13.9 1.425 36.2 2029 30203 x 95 19 11.4 15.8 1.618 41.1 2728 40603 x 120 37 13.9 18.6 1.862 47.3 3508 52203 x 150 37 15.5 20.3 2.047 52.0 4287 63803 x 185 37 17.3 22.3 2.236 56.8 5120 76203 x 240 61 19.9 25.4 2.524 64.1 6659 9910

4 x 1.5 7 1.6 4.3 0.543 13.8 169 2524 x 2.5 7 2.0 4.7 0.583 14.8 208 3094 x 4 7 2.5 5.5 0.661 16.8 280 4174 x 6 7 3.1 6.0 0.713 18.1 348 5184 x 10 7 4.0 7.1 0.854 21.7 540 8034 x 16 7 5.0 8.3 0.980 24.9 758 11284 x 25 7 6.3 9.8 1.142 29.0 1100 16354 x 35 19 7.0 10.6 1.236 31.4 1378 20504 x 50 19 8.1 11.9 1.366 34.7 1845 27454 x 70 19 9.7 13.9 1.583 40.2 2554 38004 x 95 19 11.4 15.8 1.799 45.7 3441 51204 x 120 37 13.9 18.6 2.071 52.6 4368 65004 x 150 37 15.5 20.3 2.272 57.7 5275 7850

5 x 1.5 7 1.6 4.3 0.602 15.3 204 3035 x 2.5 7 2.0 4.7 0.650 16.5 251 3735 x 4 7 2.5 5.5 0.736 18.7 349 520

24 x 1 7 1.3 3.8 1.047 26.6 504 750

6 x 1.5 7 1.6 4.3 0.622 15.8 180 2687 x 1.5 7 1.6 4.3 0.626 15.9 187 2788 x 1.5 7 1.6 4.3 0.681 17.3 212 316

12 x 1.5 7 1.6 4.3 0.827 21.0 306 45520 x 1.5 7 1.6 4.3 1.043 26.5 497 73924 x 1.5 7 1.6 4.3 1.169 29.7 624 92830 x 1.5 7 1.6 4.3 1.248 31.7 719 107037 x 1.5 7 1.6 4.3 1.358 34.5 864 1285

6 x 2.5 7 2.0 4.7 0.673 17.1 227 3387 x 2.5 7 2.0 4.7 0.677 17.2 239 3568 x 2.5 7 2.0 4.7 0.744 18.9 276 411

10 x 2.5 7 2.0 4.7 0.874 22.2 346 51512 x 2.5 7 2.0 4.7 0.906 23.0 398 59319 x 2.5 7 2.0 4.7 1.079 27.4 605 90020 x 2.5 7 2.0 4.7 1.150 29.2 648 96424 x 2.5 7 2.0 4.7 1.280 32.5 816 121530 x 2.5 7 2.0 4.7 1.366 34.7 943 140436 x 2.5 7 2.0 4.7 1.488 37.8 1138 1693

13 x 6 7 3.1 6.0 1.209 30.7 827 1231183

Page 191: Prysmian Draka - Marine & Offshore LV HV Cables

12

Application:

Armored power and control cables 0.6/1 kV with specialproperties for electrical installations in ships and offshoreunits. Temperature Class 85 °C, Flame Retardant (IEC60332-3 category “A”, “A/F”), Low Smoke, Halogen Free,Low Toxicity. Suitable for application in cold climate areas required to pass cold bent and cold impact testing at–40 °C and –35 °C, respectively.

Construction:

Generally according to IEC 60092-3 0.6/1 kV

Conductors: flexible bare annealedcopper, IEC 60228, (Class 5)sizes 1 - 300 mm2

Insulation: cross linked polyethylene (XLPE/HF XLPE) according to IEC 60092-3,IEC 60092-351 and IEEE Std 45

Assembly: cores cabled togetherFiller: halogen free filling compoundInnersheath: halogen free, flame retardant

(SHF1, IEC 60092-359)Braiding: bronze wire according to IEEE Std 45,

CDA 220, weight coverage 90% onnominal diameter according toIEC 60092-3, wire diameter 0.32 - 0.40 mm

Sheathing: halogen free, flame retardant (SHF1,IEC 60092-359); all sheath and jacketing materials shall pass tear resistance testing to 35 lbs/in (6.4 N/mm)

Sheathing color: gray (other colors are available on request)

Identification of the cores:

1 core black2 cores black, blue3 cores black, blue, brown4 cores black, blue, brown, green/yellow

Special cable properties:

Fire propagation: IEC 60332-3 category “A”, “A/F”Smoke: IEC 61034-1/2, MIL-C-24643A

(par. 4.7.27) and NES 711Acidity: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.25)Halogen content: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.26)Toxicity index: NES 713Cold properties: cold bend (–40 °C) and cold impact

(–35 °C) according to CAN/CSA-C22.2No. 0.3-Dec. ’92

Power and control cablesHXXMB EEP 0.6/1 kV IEC 60092-3

Class 5 conductors

Opmaak Control Cables 27-07-2001 15:15 Pagina 12

184

Page 192: Prysmian Draka - Marine & Offshore LV HV Cables

General data for HXXMB EEP 0.6/1 kV IEC 60092-3Class 5 conductors

number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductorcores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistancenominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 °C DC at 20 °C DCsectional area class 5 sheath sheath wire(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M’) (kg/km) (Ω/M’) (Ω/km)

1 x 35 266 8.2 11.0 0.535 13.6 0.32 0.697 17.7 106 443 660 0.169 0.5541 x 50 380 9.8 12.8 0.713 18.1 0.32 0.874 22.2 133 685 1,020 0.118 0.3861 x 70 330 11.6 15.1 0.811 20.6 0.32 0.980 24.9 149 874 1,300 0.083 0.2721 x 95 437 13.1 16.8 0.886 22.5 0.32 1.055 26.8 161 1,062 1,580 0.063 0.2061 x 120 562 15.4 19.2 0.988 25.1 0.32 1.173 29.8 179 1,310 1,950 0.049 0.1611 x 150 703 17.1 21.2 1.094 27.8 0.32 1.287 32.7 196 1,596 2,375 0.039 0.1291 x 185 851 18.5 22.8 1.165 29.6 0.32 1.358 34.5 207 1,848 2,750 0.032 0.1061 x 240 1,117 21.3 26.0 1.307 33.2 0.40 1.520 38.6 232 2,369 3,525 0.0244 0.08011 x 300 1,384 23.7 28.8 1.429 36.3 0.40 1.650 41.9 251 2,856 4,250 0.0195 0.0641

2 x 35 266 8.2 11.0 1.067 27.1 0.32 1.260 32.0 192 1,270 1,890 0.169 0.5542 x 50 380 9.8 12.8 1.228 31.2 0.40 1.402 35.6 214 1,720 2,560 0.118 0.3862 x 70 330 11.6 15.1 1.437 36.5 0.40 1.657 42.1 253 2,301 3,425 0.083 0.2722 x 95 437 13.1 16.8 1.587 40.3 0.40 1.815 46.1 277 2,822 4,200 0.063 0.206

3 x 35 266 8.2 11.0 1.154 29.3 0.32 1.346 34.2 205 1,512 2,250 0.169 0.5543 x 50 380 9.8 12.8 1.315 33.4 0.40 1.528 38.8 233 2,036 3,030 0.118 0.3863 x 70 330 11.6 15.1 1.543 39.2 0.40 1.772 45.0 270 2,755 4,100 0.083 0.2723 x 95 437 13.1 16.8 1.701 43.2 0.40 1.937 49.2 295 3,420 5,090 0.063 0.2063 x 120 562 15.4 19.2 1.929 49.0 0.40 2.173 55.2 331 4,301 6,400 0.049 0.1613 x 150 703 17.1 21.2 2.122 53.9 0.40 2.374 60.3 362 5,214 7,760 0.039 0.1293 x 185 851 18.5 22.8 2.272 57.7 0.40 2.531 64.3 386 6,064 9,025 0.032 0.1063 x 240 1,117 21.3 26.0 2.579 65.5 0.40 2.854 72.5 435 7,795 11,600 0.0244 0.0801

4 x 35 266 8.2 11.0 1.272 32.3 0.40 1.484 37.7 226 1,881 2,800 0.169 0.5544 x 50 380 9.8 12.8 1.457 37.0 0.40 1.677 42.6 256 2,486 3,700 0.118 0.3864 x 70 330 11.6 15.1 1.709 43.4 0.40 1.945 49.4 296 3,360 5,000 0.083 0.2724 x 95 437 13.1 16.8 1.890 48.0 0.40 2.134 54.2 325 4,206 6,260 0.063 0.2064 x 120 562 15.4 19.2 2.146 54.5 0.40 2.398 60.9 365 5,288 7,870 0.049 0.1614 x 150 703 17.1 21.2 2.354 59.8 0.40 2.614 66.4 398 6,384 9,500 0.039 0.129

13

Opmaak Control Cables 27-07-2001 15:15 Pagina 13

185

Page 193: Prysmian Draka - Marine & Offshore LV HV Cables

HXXM FR Power & Control cables 0.6/1 kV Fire resistant halogen free marine cable

Max. conductor temp.: 90 °CN ominal voltage : 0.6/1 kV

Application Fire resistant power and control cables for fixed installations in ships with special properties.

Standards applied

Halogen Free - According to IEC 60754-1/2 Low smoke - According to IEC 61034-1/2 Flame retardant - According to IEC 60332-3 cat A Toxicity index - According to NES 713 Fire resistance - According to IEC 60331

Construction

Conductor Annealed stranded circular copper Insulation Mica tape and Crosslinked polyethylene, XLPE/HF XLPE to IEC 60092/3 Inner sheath Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath Flame retardant halogen-free thermoplastic compound, SHF1

Marking text DRAKA HXXM-FR 0,6/1kV IEC 60092-3 3 x 10 mm2 ETL Listed 9801094 (year) (code)

Outer sheath colour Grey Identification the cores One core Black Two cores Black, blue Three cores Black, blue, Brown Four cores Black, blue. Brown, green/yellowFive cores and up Black, numbered

186

Page 194: Prysmian Draka - Marine & Offshore LV HV Cables

RANGE AND DIMENSIONS

Prod.number No. of pairs

and cond.area

(mm2)

Cross section screen (mm2)

Conductor-diameter

(mm) Corediameter

(mm) Diameter

outer sheath (mm)

Diam under

armour mm

Weight of

cable approx. (kg/km)

Max. current

(A) Resistance at 20 oC DC (Ohm/km)

Resistance at 90 oC 50

Hz (Ohm/km)

123497 3 x 10 n.a. 3.92 7.04 19.20 n.a. 635 65 0.56 2.33 123498 3 x 25 n.a. 6.27 9.80 26.00 n.a. 1316 110 0.222 0.927 123499 3 x 35 n.a. 7.00 10.57 28.20 n.a. 1685 137 0.160 0.669 123501 3 x 50 n.a. 8.10 11.88 31.50 n.a. 2195 167 0.118 0.494 123502 3 x 120 n.a. 15.40 20.02 50.80 n.a. 5415 301 0.047 0.198 123503 3 x 95 n.a. 11.40 15.81 41.10 n.a. 4045 259 0.059 0.248 123504 3 x 150 n.a. 16.90 21.67 54.70 n.a. 6475 347 0.038 0.161 123506 4 x 35 n.a. 7.00 10.57 31.40 n.a. 2120 137 0.160 0.669 123509 7 x 1,5 n.a. 1.57 4.30 15.90 n.a. 285 20 3.70 15.4 123519 3 x 16 n.a. 4.97 8.29 22.10 n.a. 895 87 0.35 1.47 123521 3 x 70 n.a. 9.7 13.90 36.20 n.a. 3010 214 0.082 0.344 124663 4 x 3 x 1 n.a. 1.29 3.81 23.10 29.7 485 n.a. 3.70 n.a.

Installation recommendations Minimum Bending Radius

during Installation Minimum Bending

Radius Fixed Installed Maximum Tensile Load

During Installation Minimum Installation

Temperature 8 x D 6 x D 50 N * total cross section

conductors -10 °C

1610 Greens Road, Suite 200, Houston TX 77032 Phone: 281-209-1070, Toll Free: 888-354-2225, Fax 281-851-1433 Website: www.DrakaMOG.com

187

Page 195: Prysmian Draka - Marine & Offshore LV HV Cables

30

Application:

Unarmored, individually shielded and isolated instrumen-tation and communication cables 0.6/1 kV with special properties for electrical installations in ships and offshoreunits. Temperature Class 85 °C, Flame Retardant (IEC 60332-3 category “A”, “A/F”), Low Smoke, HalogenFree, Low Toxicity. Suitable for application in cold climateareas required to pass cold bend and cold impact testingat –40 °C and –35 °C, respectively.

Construction:

According to IEC 60092-3 with enhanced properties.

Conductors: stranded bare annealedcopper, IEC 60228, sizes 1 - 4 mm2

Insulation: cross linked polyethylene (XLPE/HF XLPE) according to IEC 60092-3,IEC 60092-351 and IEEE Std 45

Twisting: cores twisted to a pair/triadIndividual shield tinned copper drain wire; alumi-and isolation: num/polyester tape; polyester tapeAssembly: shielded pairs/triads cabled togetherSheathing: halogen free, flame retardant

(SHF1, IEC 60092-359); all sheath andjacketing materials shall pass tearresistance testing to 35 lbs/in(6.4 N/mm)

Sheathing color: gray (other colors are available onrequest)

Identification of the groups:

1 pair black, whitemulti pairs black, white

(groups sequential numbered1-1, 2-2, 3-3 etc.)

1 triad black, white, redmulti triads black, white, red

(groups sequential numbered1-1-1, 2-2-2, 3-3-3, etc.)

Special cable properties:

Fire propagation: IEC 60332-3 category “A”, “A/F”Smoke: IEC 61034-1/2, MIL-C-24643A

(par. 4.7.27) and NES 711Acidity: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.25)Halogen content: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.26)Toxicity index: NES 713Cold properties: cold bend (–40 °C) and cold impact

(–35 °C) according to CAN/CSA-C22.2No. 0.3-Dec. ’92

*Remark: Other constructions available on request

Instrumentation and communication cablesHXXM EEP 0.6/1 kV IEC 60092-3

Individually shielded and isolated*

Opmaak Control Cables 27-07-2001 15:19 Pagina 24

188

Page 196: Prysmian Draka - Marine & Offshore LV HV Cables

31

General data for HXXM Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3

number of number of nominal nominal nominal nominal minimum approxi- approxi- conductor conductorcores and wires in conductor core outer outer bending mate mate resistance resistancenominal cross conductor diameter diameter diameter diameter radius weight weight at 20 °C DC at 20 °C DCsectional area class 2(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (lbs/M’) (kg/km) (Ω/M’) (Ω/km)

1 x 2 x 1 7 1.3 3.1 0.350 8.9 45 57 85 5.6 18.52 x 2 x 1 7 1.3 3.1 0.567 14.4 86 202 300 5.6 18.54 x 2 x 1 7 1.3 3.1 0.673 17.1 103 296 440 5.6 18.57 x 2 x 1 7 1.3 3.1 0.748 19.0 114 336 500 5.6 18.5

10 x 2 x 1 7 1.3 3.1 0.984 25.0 150 504 750 5.6 18.512 x 2 x 1 7 1.3 3.1 1.047 26.6 160 571 850 5.6 18.516 x 2 x 1 7 1.3 3.1 1.185 30.1 181 739 1,100 5.6 18.519 x 2 x 1 7 1.3 3.1 1.209 30.7 184 806 1,200 5.6 18.5

1 x 2 x 1.5 7 1.6 3.4 0.371 9.4 57 67 100 3.7 12.32 x 2 x 1.5 7 1.6 3.4 0.606 15.4 92 235 350 3.7 12.35 x 2 x 1.5 7 1.6 3.4 0.799 20.3 122 363 540 3.7 12.3

12 x 2 x 1.5 7 1.6 3.4 1.130 28.7 172 659 980 3.7 12.3

12 x 2 x 2.5 7 2.0 3.8 1.272 32.3 194 853 1.270 2.30 7.56

2 x 2 x 4 7 2.5 4.6 0.787 20.0 120 356 530 1.43 4.70

1 x 3 x 1 7 1.3 3.1 0.369 9.4 47 67 100 5.6 18.5

1 x 3 x 1.5 7 1.6 3.4 0.392 10.0 50 87 130 3.7 12.310 x 3 x 1.5 7 1.6 3.4 1.240 31.5 189 806 1,200 3.7 12.316 x 3 x 1.5 7 1.6 3.4 1.449 36.8 221 1,062 1,580 3.7 12.3

Electrical characteristics for HXXM Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3

cross section of the mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductanceconductor core to core (nF/M’) core to core (nF/km) core to shield (nF/M’) core to shield (nF/km) (mH/M’) (mH/km)(mm2) pair & triad pair & triad pair & triad pair & triad pair & triad pair & triad

1 19 63 33 108 0.22 0.721.5 21 70 37 121 0.21 0.682.5 24 79 41 136 0.20 0.644 25 82 43 142 0.19 0.62

Opmaak Control Cables 27-07-2001 15:19 Pagina 25

189

Page 197: Prysmian Draka - Marine & Offshore LV HV Cables

24

Application:

Unarmored, individually shielded and isolated instrumen-tation and communication cables 250 V with special properties for electrical installations in ships and offshoreunits. Temperature Class 85 °C, Flame Retardant (IEC 60332-3 category “A”, “A/F”), Low Smoke, HalogenFree, Low Toxicity. Suitable for application in cold climateareas required to pass cold bend and cold impact testingat –40 °C and –35 °C, respectively.

Construction:

According to IEC 60092-3 with enhanced properties.

Conductors: stranded bare annealedcopper, IEC 60228, sizes 1 - 4 mm2

Insulation: cross linked polyethylene (XLPE/HF XLPE) according to IEC 60092-3,IEC 60092-351 and IEEE Std 45

Twisting: cores twisted to a pair/triadIndividual shield tinned copper drain wire; alumi-and isolation: num/polyester tape; polyester tapeAssembly: shielded pairs/triads cabled togetherSheathing: halogen free, flame retardant

(SHF1, IEC 60092-359); all sheath andjacketing materials shall pass tearresistance testing to 35 lbs/in(6.4 N/mm)

Sheathing color: gray (other colors are available onrequest)

Identification of the groups:

1 pair black, whitemulti pairs black, white

(groups sequential numbered1-1, 2-2, 3-3 etc.)

1 triad black, white, redmulti triads black, white, red

(groups sequential numbered1-1-1, 2-2-2, 3-3-3, etc.)

Special cable properties:

Fire propagation: IEC 60332-3 category “A”, “A/F”Smoke: IEC 61034-1/2, MIL-C-24643A

(par. 4.7.27) and NES 711Acidity: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.25)Halogen content: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.26)Toxicity index: NES 713Cold properties: cold bend (–40 °C) and cold impact

(–35 °C) according to CAN/CSA-C22.2No. 0.3-Dec. ’92

*Remark: Other constructions available on request

Instrumentation and communication cablesHXXM EEP 250 V IEC 60092-3

Individually shielded and isolated*

Opmaak Control Cables 27-07-2001 15:19 Pagina 24

190

Page 198: Prysmian Draka - Marine & Offshore LV HV Cables

25

General data for HXXM Individually shielded and isolated EEP 250V IEC 60092-3

number of number of nominal nominal nominal nominal minimum approxi- approxi- conductor conductorcores and wires in conductor core outer outer bending mate mate resistance resistancenominal cross conductor diameter diameter diameter diameter radius weight weight at 20 °C DC at 20 °C DCsectional area class 2(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (lbs/M’) (kg/km) (Ω/M’) (Ω/km)

1 x 2 x 1 7 1.3 3.1 0.350 8.9 45 57 85 5.6 18.52 x 2 x 1 7 1.3 3.1 0.567 14.4 86 202 300 5.6 18.54 x 2 x 1 7 1.3 3.1 0.673 17.1 103 296 440 5.6 18.57 x 2 x 1 7 1.3 3.1 0.748 19.0 114 336 500 5.6 18.5

10 x 2 x 1 7 1.3 3.1 0.984 25.0 150 504 750 5.6 18.512 x 2 x 1 7 1.3 3.1 1.047 26.6 160 571 850 5.6 18.516 x 2 x 1 7 1.3 3.1 1.185 30.1 181 739 1,100 5.6 18.519 x 2 x 1 7 1.3 3.1 1.209 30.7 184 806 1,200 5.6 18.5

1 x 2 x 1.5 7 1.6 3.4 0.371 9.4 57 67 100 3.7 12.32 x 2 x 1.5 7 1.6 3.4 0.606 15.4 92 235 350 3.7 12.35 x 2 x 1.5 7 1.6 3.4 0.799 20.3 122 363 540 3.7 12.3

12 x 2 x 1.5 7 1.6 3.4 1.130 28.7 172 659 980 3.7 12.3

12 x 2 x 2.5 7 2.0 3.8 1.272 32.3 194 853 1.270 2.30 7.56

2 x 2 x 4 7 2.5 4.6 0.787 20.0 120 356 530 1.43 4.70

1 x 3 x 1 7 1.3 3.1 0.369 9.4 47 67 100 5.6 18.5

1 x 3 x 1.5 7 1.6 3.4 0.392 10.0 50 87 130 3.7 12.310 x 3 x 1.5 7 1.6 3.4 1.240 31.5 189 806 1,200 3.7 12.316 x 3 x 1.5 7 1.6 3.4 1.449 36.8 221 1,062 1,580 3.7 12.3

Electrical characteristics for HXXM Individually shielded and isolated EEP 250 V IEC 60092-3

cross section of the mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductanceconductor core to core (nF/M’) core to core (nF/km) core to shield (nF/M’) core to shield (nF/km) (mH/M’) (mH/km)(mm2) pair & triad pair & triad pair & triad pair & triad pair & triad pair & triad

1 19 63 33 108 0.22 0.721.5 21 70 37 121 0.21 0.682.5 24 79 41 136 0.20 0.644 25 82 43 142 0.19 0.62

Opmaak Control Cables 27-07-2001 15:19 Pagina 25

191

Page 199: Prysmian Draka - Marine & Offshore LV HV Cables

12

Application:

Armored power and control cables 0.6/1 kV with specialproperties for electrical installations in ships and offshoreunits. Temperature Class 85 °C, Flame Retardant (IEC60332-3 category “A”, “A/F”), Low Smoke, Halogen Free,Low Toxicity. Suitable for application in cold climate areas required to pass cold bent and cold impact testing at–40 °C and –35 °C, respectively.

Construction:

Generally according to IEC 60092-3 0.6/1 kV

Conductors: flexible bare annealedcopper, IEC 60228, (Class 5)sizes 1 - 300 mm2

Insulation: cross linked polyethylene (XLPE/HF XLPE) according to IEC 60092-3,IEC 60092-351 and IEEE Std 45

Assembly: cores cabled togetherFiller: halogen free filling compoundInnersheath: halogen free, flame retardant

(SHF1, IEC 60092-359)Braiding: bronze wire according to IEEE Std 45,

CDA 220, weight coverage 90% onnominal diameter according toIEC 60092-3, wire diameter 0.32 - 0.40 mm

Sheathing: halogen free, flame retardant (SHF1,IEC 60092-359); all sheath and jacketing materials shall pass tear resistance testing to 35 lbs/in (6.4 N/mm)

Sheathing color: gray (other colors are available on request)

Identification of the cores:

1 core black2 cores black, blue3 cores black, blue, brown4 cores black, blue, brown, green/yellow

Special cable properties:

Fire propagation: IEC 60332-3 category “A”, “A/F”Smoke: IEC 61034-1/2, MIL-C-24643A

(par. 4.7.27) and NES 711Acidity: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.25)Halogen content: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.26)Toxicity index: NES 713Cold properties: cold bend (–40 °C) and cold impact

(–35 °C) according to CAN/CSA-C22.2No. 0.3-Dec. ’92

Power and control cablesHXXMB EEP 0.6/1 kV IEC 60092-3

Class 5 conductors

Opmaak Control Cables 27-07-2001 15:15 Pagina 12

192

Page 200: Prysmian Draka - Marine & Offshore LV HV Cables

General data for HXXMB EEP 0.6/1 kV IEC 60092-3Class 5 conductors

number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductorcores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistancenominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 °C DC at 20 °C DCsectional area class 5 sheath sheath wire(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M’) (kg/km) (Ω/M’) (Ω/km)

1 x 35 266 8.2 11.0 0.535 13.6 0.32 0.697 17.7 106 443 660 0.169 0.5541 x 50 380 9.8 12.8 0.713 18.1 0.32 0.874 22.2 133 685 1,020 0.118 0.3861 x 70 330 11.6 15.1 0.811 20.6 0.32 0.980 24.9 149 874 1,300 0.083 0.2721 x 95 437 13.1 16.8 0.886 22.5 0.32 1.055 26.8 161 1,062 1,580 0.063 0.2061 x 120 562 15.4 19.2 0.988 25.1 0.32 1.173 29.8 179 1,310 1,950 0.049 0.1611 x 150 703 17.1 21.2 1.094 27.8 0.32 1.287 32.7 196 1,596 2,375 0.039 0.1291 x 185 851 18.5 22.8 1.165 29.6 0.32 1.358 34.5 207 1,848 2,750 0.032 0.1061 x 240 1,117 21.3 26.0 1.307 33.2 0.40 1.520 38.6 232 2,369 3,525 0.0244 0.08011 x 300 1,384 23.7 28.8 1.429 36.3 0.40 1.650 41.9 251 2,856 4,250 0.0195 0.0641

2 x 35 266 8.2 11.0 1.067 27.1 0.32 1.260 32.0 192 1,270 1,890 0.169 0.5542 x 50 380 9.8 12.8 1.228 31.2 0.40 1.402 35.6 214 1,720 2,560 0.118 0.3862 x 70 330 11.6 15.1 1.437 36.5 0.40 1.657 42.1 253 2,301 3,425 0.083 0.2722 x 95 437 13.1 16.8 1.587 40.3 0.40 1.815 46.1 277 2,822 4,200 0.063 0.206

3 x 35 266 8.2 11.0 1.154 29.3 0.32 1.346 34.2 205 1,512 2,250 0.169 0.5543 x 50 380 9.8 12.8 1.315 33.4 0.40 1.528 38.8 233 2,036 3,030 0.118 0.3863 x 70 330 11.6 15.1 1.543 39.2 0.40 1.772 45.0 270 2,755 4,100 0.083 0.2723 x 95 437 13.1 16.8 1.701 43.2 0.40 1.937 49.2 295 3,420 5,090 0.063 0.2063 x 120 562 15.4 19.2 1.929 49.0 0.40 2.173 55.2 331 4,301 6,400 0.049 0.1613 x 150 703 17.1 21.2 2.122 53.9 0.40 2.374 60.3 362 5,214 7,760 0.039 0.1293 x 185 851 18.5 22.8 2.272 57.7 0.40 2.531 64.3 386 6,064 9,025 0.032 0.1063 x 240 1,117 21.3 26.0 2.579 65.5 0.40 2.854 72.5 435 7,795 11,600 0.0244 0.0801

4 x 35 266 8.2 11.0 1.272 32.3 0.40 1.484 37.7 226 1,881 2,800 0.169 0.5544 x 50 380 9.8 12.8 1.457 37.0 0.40 1.677 42.6 256 2,486 3,700 0.118 0.3864 x 70 330 11.6 15.1 1.709 43.4 0.40 1.945 49.4 296 3,360 5,000 0.083 0.2724 x 95 437 13.1 16.8 1.890 48.0 0.40 2.134 54.2 325 4,206 6,260 0.063 0.2064 x 120 562 15.4 19.2 2.146 54.5 0.40 2.398 60.9 365 5,288 7,870 0.049 0.1614 x 150 703 17.1 21.2 2.354 59.8 0.40 2.614 66.4 398 6,384 9,500 0.039 0.129

13

Opmaak Control Cables 27-07-2001 15:15 Pagina 13

193

Page 201: Prysmian Draka - Marine & Offshore LV HV Cables

Application:

Armored fire resistant power and control cables 0.6/1 kVwith special properties for electrical installations in shipsand offshore units. Temperature Class 85 °C, FlameRetardant (IEC 60332-3 category “A”, “A/F”), Low Smoke,Halogen Free, Low Toxicity and Fire Resistant (IEC 60331 950 °C). Suitable for application in cold climateareas required to pass cold bend and cold impact testingat –40 °C and –35 °C, respectively.

Construction:

Generally according to IEC 60092-3 0.6/1 kV

Conductors: stranded bare annealedcopper, IEC 60228, (Class 2) sizes 1 - 300 mm2

Insulation: mica tape, and cross linked polyethy-lene (XLPE/HF XLPE) according toIEC 60092-3, IEC 60092-351 and IEEEStd 45

Assembly: cores cabled togetherFiller: halogen free filling compoundInnersheath: halogen free, flame retardant,

(SHF1, IEC 60092-359)Braiding: bronze wires according to IEEE Std

45, CDA 220, weight coverage 90%on nominal diameter, according toIEC 60092-3, wire diameter 0.32 - 0.40 mm

Sheathing: halogen free, flame retardant (SHF1, IEC 60092-359); all sheath and jacketing materials shall pass tear resistance testing to 35 Ibs/in (6.4 N/mm)

Sheathing color: gray (other colors are available onrequest)

Identification of the cores:

1 core black2 cores black, blue3 cores black, blue, brown4 cores black, blue, brown, green/yellow5 cores and up: black, numbered

Special cable properties:

Fire propagation: IEC 60332-3 category “A”, “A/F”Fire resistance: IEC 60331 950 °CSmoke: IEC 61034-1/2 , MIL-C-24643A

(par. 4.7.27) and NES 711Acidity: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.25)Halogen content: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.26)Toxicity index: NES 713 Cold properties: cold bend (–40 °C) and cold impact

(–35 °C) according to CAN/CSA-C22.2No. 0.3-Dec. ’92

Power and control cablesHXXMB-FR EEP 0.6/1 kV IEC 60092-3

Class 2 conductors

6

Opmaak Control Cables 27-07-2001 15:13 Pagina 6

194

Page 202: Prysmian Draka - Marine & Offshore LV HV Cables

7

General data for HXXMB-FR EEP 0.6/1 kV IEC 60092-3Class 2 conductors

number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductorcores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistancenominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 °C DC at 20 °C DCsectional area class 2 sheath sheath wire(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M’) (kg/km) (Ω/M’) (Ω/km)

1 x 1.5 7 1.6 4.3 0.252 6.4 0.32 0.394 10.0 50 111 165 3.7 12.11 x 2.5 7 2.0 4.7 0.272 6.9 0.32 0.413 10.5 53 121 180 2.26 7.411 x 4 7 2.5 5.5 0.299 7.6 0.32 0.441 11.2 56 144 215 1.41 4.611 x 6 7 3.1 6.0 0.319 8.1 0.32 0.461 11.7 59 161 240 0.94 3.081 x 10 7 4.0 7.1 0.370 9.4 0.32 0.516 13.1 79 212 315 0.56 1.831 x 16 7 5.0 8.3 0.421 10.7 0.32 0.575 14.6 88 276 410 0.35 1.151 x 25 7 6.3 9.8 0.492 12.5 0.32 0.646 16.4 98 363 540 0.222 0.7271 x 35 19 7.0 10.6 0.520 13.2 0.32 0.681 17.3 104 437 650 0.160 0.5241 x 50 19 8.1 11.9 0.677 17.2 0.32 0.839 21.3 128 645 960 0.118 0.3871 x 70 19 9.7 13.9 0.764 19.4 0.32 0.933 23.7 142 840 1,250 0.082 0.2681 x 95 19 11.4 15.8 0.846 21.5 0.32 1.016 25.8 155 1,055 1,570 0.059 0.1931 x 120 37 13.9 18.6 0.961 24.4 0.32 1.146 29.1 175 1,290 1,920 0.047 0.1531 x 150 37 15.5 20.3 1.059 26.9 0.32 1.252 31.8 191 1,546 2,300 0.038 0.1241 x 185 37 17.3 22.3 1.150 29.2 0.32 1.343 34.1 205 1,848 2,750 0.0302 0.09911 x 240 61 19.9 25.4 1.283 32.6 0.40 1.496 38.0 228 2,385 3,550 0.0230 0.07541 x 300 61 22.2 28.1 1.398 35.5 0.40 1.618 41.1 247 2,856 4,250 0.0183 0.0601

2 x 1.5 7 1.6 4.3 0.461 11.7 0.32 0.614 15.6 94 255 380 3.7 12.12 x 2.5 7 2.0 4.7 0.508 12.9 0.32 0.661 16.8 101 302 450 2.26 7.412 x 4 7 2.5 5.5 0.579 14.7 0.32 0.740 18.8 113 383 570 1.41 4.612 x 6 7 3.1 6.0 0.630 16.0 0.32 0.791 20.1 121 450 670 0.94 3.082 x 10 7 4.0 7.1 0.728 18.5 0.32 0.890 22.6 136 591 880 0.56 1.832 x 16 7 5.0 8.3 0.850 21.6 0.32 1.020 25.9 155 806 1,200 0.35 1.152 x 25 7 6.3 9.8 0.976 24.8 0.32 1.161 29.5 177 1,075 1,600 0.222 0.7272 x 35 19 7.0 10.6 1.035 26.3 0.32 1.228 31.2 187 1,243 1,850 0.160 0.5242 x 50 19 8.1 11.9 1.157 29.4 0.40 1.370 34.8 209 1,646 2,450 0.118 0.3872 x 70 19 9.7 13.9 1.346 34.2 0.40 1.567 39.8 239 2,184 3,250 0.082 0.2682 x 95 19 11.4 15.8 1.512 38.4 0.40 1.740 44.2 265 2,755 4,100 0.059 0.193

3 x 1.5 7 1.6 4.3 0.492 12.5 0.32 0.646 16.4 98 282 420 3.7 12.13 x 2.5 7 2.0 4.7 0.535 13.6 0.32 0.689 17.5 105 329 490 2.26 7.413 x 4 7 2.5 5.5 0.614 15.6 0.32 0.776 19.7 118 417 620 1.41 4.613 x 6 7 3.1 6.0 0.669 17.0 0.32 0.831 21.1 127 497 740 0.94 3.083 x 10 7 4.0 7.1 0.772 19.6 0.32 0.941 23.9 143 672 1,000 0.56 1.833 x 16 7 5.0 8.3 0.886 22.5 0.32 1.063 27.0 162 874 1,300 0.35 1.153 x 25 7 6.3 9.8 1.039 26.4 0.32 1.224 31.1 187 1,210 1,800 0.222 0.7273 x 35 19 7.0 10.6 1.110 28.2 0.32 1.303 33.1 199 1,478 2,200 0.160 0.5243 x 50 19 8.1 11.9 1.240 31.5 0.40 1.453 36.9 221 1,949 2,900 0.118 0.3873 x 70 19 9.7 13.9 1.425 36.2 0.40 1.654 42.0 252 2,587 3,850 0.082 0.2683 x 95 19 11.4 15.8 1.618 41.1 0.40 1.854 47.1 283 3,360 5,000 0.059 0.1933 x 120 37 13.9 18.6 1.862 47.3 0.40 2.106 53.5 321 4,133 6,150 0.047 0.1533 x 150 37 15.5 20.3 2.047 52.0 0.40 2.299 58.4 350 5,006 7,450 0.038 0.1243 x 185 37 17.3 22.3 2.236 56.8 0.40 2.496 63.4 380 6,048 9,000 0.0302 0.09913 x 240 61 19.9 25.4 2.524 64.1 0.40 2.799 71.1 427 7,728 11,500 0.0230 0.0754

4 x 1.5 7 1.6 4.3 0.543 13.8 0.32 0.697 17.7 106 323 480 3.7 12.14 x 2.5 7 2.0 4.7 0.583 14.8 0.32 0.744 18.9 113 376 560 2.26 7.414 x 4 7 2.5 5.5 0.661 16.8 0.32 0.823 20.9 125 470 700 1.41 4.614 x 6 7 3.1 6.0 0.713 18.1 0.32 0.874 22.2 133 558 830 0.94 3.084 x 10 7 4.0 7.1 0.854 21.7 0.32 1.024 26.0 156 806 1,200 0.56 1.834 x 16 7 5.0 8.3 0.980 24.9 0.32 1.165 29.6 178 1,075 1,600 0.35 1.154 x 25 7 6.3 9.8 1.142 29.0 0.32 1.335 33.9 203 1,478 2,200 0.222 0.7274 x 35 19 7.0 10.6 1.236 31.4 0.40 1.449 36.8 221 1,881 2,800 0.160 0.5244 x 50 19 8.1 11.9 1.366 34.7 0.40 1.587 40.3 242 2,385 3,550 0.118 0.3874 x 70 19 9.7 13.9 1.583 40.2 0.40 1.819 46.2 277 3,192 4,750 0.082 0.2684 x 95 19 11.4 15.8 1.799 45.7 0.40 2.043 51.9 311 4,166 6,200 0.059 0.1934 x 120 37 13.9 18.6 2.071 52.6 0.40 2.323 59.0 354 5,107 7,600 0.047 0.1534 x 150 37 15.5 20.3 2.272 57.7 0.40 2.531 64.3 386 6,182 9,200 0.038 0.124

5 x 1.5 7 1.6 4.3 0.602 15.3 0.32 0.764 19.4 116 376 560 3.7 12.15 x 2.5 7 2.0 4.7 0.650 16.5 0.32 0.811 20.6 124 437 650 2.26 7.415 x 4 7 2.5 5.5 0.736 18.7 0.32 0.906 23.0 138 571 850 1.41 4.61

24 x 1 7 1.3 3.8 1.047 26.6 0.32 1.228 31.2 187 806 1,200 5.5 18.1

6 x 1.5 7 1.6 4.3 0.622 15.8 0.32 0.783 19.9 119 349 520 3.7 12.17 x 1.5 7 1.6 4.3 0.626 15.9 0.32 0.787 20.0 120 373 555 3.7 12.18 x 1.5 7 1.6 4.3 0.681 17.3 0.32 0.843 21.4 128 400 595 3.7 12.1

12 x 1.5 7 1.6 4.3 0.827 21.0 0.32 0.996 25.3 152 548 815 3.7 12.120 x 1.5 7 1.6 4.3 1.043 26.5 0.32 1.228 31.2 187 796 1,185 3.7 12.124 x 1.5 7 1.6 4.3 1.169 29.7 0.32 1.362 34.6 208 1,008 1,500 3.7 12.130 x 1.5 7 1.6 4.3 1.248 31.7 0.40 1.461 37.1 223 1,162 1,730 3.7 12.137 x 1.5 7 1.6 4.3 1.358 34.5 0.40 1.571 39.9 239 1,378 2,050 3.7 12.1

6 x 2.5 7 2.0 4.7 0.673 17.1 0.32 0.835 21.2 127 403 600 2.26 7.417 x 2.5 7 2.0 4.7 0.677 17.2 0.32 0.839 21.3 128 430 640 2.26 7.418 x 2.5 7 2.0 4.7 0.744 18.9 0.32 0.913 23.2 139 497 740 2.26 7.41

10 x 2.5 7 2.0 4.7 0.874 22.2 0.32 1.043 26.5 159 598 890 2.26 7.4112 x 2.5 7 2.0 4.7 0.906 23.0 0.32 1.083 27.5 165 672 1,000 2.26 7.4119 x 2.5 7 2.0 4.7 1.079 27.4 0.32 1.272 32.3 194 941 1,400 2.26 7.4120 x 2.5 7 2.0 4.7 1.150 29.2 0.32 1.343 34.1 205 1,008 1,500 2.26 7.4124 x 2.5 7 2.0 4.7 1.280 32.5 0.40 1.492 37.9 227 1,277 1,900 2.26 7.4130 x 2.5 7 2.0 4.7 1.366 34.7 0.40 1.587 40.3 242 1,478 2,200 2.26 7.4136 x 2.5 7 2.0 4.7 1.488 37.8 0.40 1.709 43.4 260 1,680 2,500 2.26 7.41

13 x 6 7 3.1 6.0 1.209 30.7 0.32 1.409 35.8 215 1,210 1,800 0.94 3.08

Opmaak Control Cables 27-07-2001 15:13 Pagina 7

195

Page 203: Prysmian Draka - Marine & Offshore LV HV Cables

Application:

Armored fire resistant power and control cables 0.6/1 kVwith special properties for electrical installations in shipsand offshore units. Temperature Class 85 °C, FlameRetardant (IEC 60332-3 category “A”, “A/F”), Low Smoke,Halogen Free, Low Toxicity and Fire Resistant (IEC 60331 950 °C). Suitable for application in cold climateareas required to pass cold bend and cold impact testingat –40 °C and –35 °C, respectively.

Construction:

Generally according to IEC 60092-3 0.6/1 kV

Conductors: flexible bare annealedcopper, IEC 60228, (Class 5) sizes 1 - 300 mm2

Insulation: mica tape, and cross linked polyethy-lene (XLPE/HF XLPE) according toIEC 60092-3, IEC 60092-351 and IEEEStd 45

Assembly: cores cabled togetherFiller: halogen free filling compoundInnersheath: halogen free, flame retardant,

(SHF1, IEC 60092-359)Braiding: bronze wires according to IEEE Std

45, CDA 220, weight coverage 90%on nominal diameter, according toIEC 60092-3, wire diameter 0.32 - 0.40 mm

Sheathing: halogen free, flame retardant (SHF1,IEC 60092-359); all sheath and jacketing materials shall pass tear resistance testing to 35 lbs/in (6.4 N/mm)

Sheathing color: gray (other colors are available onrequest)

Identification of the cores:

1 core black2 cores black, blue3 cores black, blue, brown4 cores black, blue, brown, green/yellow

Special cable properties:

Fire propagation: IEC 60332-3 category “A”, “A/F”Fire resistance: IEC 60331 950 °CSmoke: IEC 61034-1/2 , MIL-C-24643A

(par. 4.7.27) and NES 711Acidity: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.25)Halogen content: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.26)Toxicity index: NES 713 Cold properties: cold bend (–40 °C) and cold impact

(–35 °C) according to CAN/CSA-C22.2No. 0.3-Dec. ’92

Power and control cablesHXXMB-FR EEP 0.6/1 kV IEC 60092-3

Class 5 conductors

8

Opmaak Control Cables 27-07-2001 15:14 Pagina 8

196

Page 204: Prysmian Draka - Marine & Offshore LV HV Cables

9

General data for HXXMB-FR EEP 0.6/1 kV IEC 60092-3Class 5 conductors

number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductorcores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistancenominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 °C DC at 20 °C DCsectional area class 5 sheath sheath wire(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M’) (kg/km) (Ω/M’) (Ω/km)

1 x 35 266 8.2 11.7 0.563 14.3 0.32 0.724 18.4 110 454 675 0.169 0.5541 x 50 380 9.8 13.5 0.740 18.8 0.32 0.902 22.9 137 706 1,050 0.118 0.3861 x 70 330 11.6 15.8 0.839 21.3 0.32 1.008 25.6 154 907 1,350 0.083 0.2721 x 95 437 13.1 17.5 0.913 23.2 0.32 1.083 27.5 165 1,075 1,600 0.063 0.2061 x 120 562 15.4 20.0 1.020 25.9 0.32 1.205 30.6 184 1,337 1,990 0.049 0.1611 x 150 703 17.1 21.9 1.122 28.5 0.32 1.315 33.4 200 1,629 2,425 0.039 0.1291 x 185 851 18.5 23.5 1.193 30.3 0.32 1.386 35.2 211 1,868 2,780 0.032 0.1061 x 240 1,117 21.3 26.8 1.339 34.0 0.40 1.551 39.4 236 2,396 3,565 0.0244 0.08011 x 300 1,384 23.7 29.6 1.457 37.0 0.40 1.677 42.6 256 2,856 4,250 0.0195 0.0641

2 x 35 266 8.2 11.7 1.134 28.8 0.32 1.327 33.7 202 1,361 2,025 0.169 0.5542 x 50 380 9.8 13.5 1.303 33.1 0.40 1.516 38.5 231 1,831 2,725 0.118 0.3862 x 70 330 11.6 15.8 1.496 38.0 0.40 1.717 43.6 262 2,385 3,550 0.083 0.2722 x 95 437 13.1 17.5 1.646 41.8 0.40 1.874 47.6 286 2,940 4,375 0.063 0.206

3 x 35 266 8.2 11.7 1.217 30.9 0.32 1.409 35.8 215 1,593 2,370 0.169 0.5543 x 50 380 9.8 13.5 1.378 35.0 0.40 1.591 40.4 242 2,150 3,200 0.118 0.3863 x 70 330 11.6 15.8 1.602 40.7 0.40 1.831 46.5 279 2,873 4,275 0.083 0.2723 x 95 437 13.1 17.5 1.764 44.8 0.40 2.000 50.8 305 3,528 5,250 0.063 0.2063 x 120 562 15.4 20.0 2.000 50.8 0.40 2.244 57.0 342 4,421 6,580 0.049 0.1613 x 150 703 17.1 21.9 2.185 55.5 0.40 2.437 61.9 371 5,342 7,950 0.039 0.1293 x 185 851 18.5 23.5 2.350 59.7 0.40 2.610 66.3 398 6,249 9,300 0.032 0.1063 x 240 1,117 21.3 26.8 2.642 67.1 0.40 2.917 74.1 445 7,929 11,800 0.0244 0.0801

4 x 35 266 8.2 11.7 1.346 34.2 0.40 1.559 39.6 238 1,982 2,950 0.169 0.5544 x 50 380 9.8 13.5 1.524 38.7 0.40 1.744 44.3 266 2,570 3,825 0.118 0.3864 x 70 330 11.6 15.8 1.780 45.2 0.40 2.016 51.2 307 3,467 5,160 0.083 0.2724 x 95 437 13.1 17.5 1.961 49.8 0.40 2.205 56.0 336 4,314 6,240 0.063 0.2064 x 120 562 15.4 20.0 2.224 56.5 0.40 2.476 62.9 377 5,443 8,100 0.049 0.1614 x 150 703 17.1 21.9 2.425 61.6 0.40 2.685 68.2 409 6,552 9,750 0.039 0.129

Opmaak Control Cables 27-07-2001 15:14 Pagina 9

197

Page 205: Prysmian Draka - Marine & Offshore LV HV Cables

18

Application:

Armored overall shielded fire resistant instrumentationand communication cables 0.6/1 kV with special propertiesfor electrical installations in ships and offshore units.Temperature Class 85 °C, Flame Retardant (IEC 60332-3category “A”, “A/F”), Low Smoke, Halogen Free, LowToxicity and Fire Resistant (IEC 60331 950 °C). Suitable forapplication in cold climate areas required to pass coldbend and cold impact testing at –40 °C and –35 °C, respectively.

Construction:

According to IEC 60092-3 with enhanced properties.

Conductors: stranded bare annealedcopper, IEC 60 228, sizes 1 to 2.5 mm2

Insulation: mica tape, and cross linked polyethy-lene (XLPE/HF XLPE) according toIEC 60092-3, IEC 60092-351 andIEEE Std 45

Twisting: cores twisted to a pair/triad/quadOverall shield: tinned copper drain wire; alumi-

num/polyester tape; polyester tapeInnersheath: halogen free, flame retardant

(SHF1, IEC 60092-359)Braiding: bronze wires according to IEEE

Std 45, CDA 220, weight coverage90% on nominal diameter accordingto IEC 60092-3, wire diameter 0.32 - 0.40 mm

Sheathing: halogen free, flame retardant(SHF1, IEC 60092-359); all sheath andjacketing materials shall pass tearresistance testing to 35 lbs/in(6.4 N/mm)

Sheathing color: gray (other colors are available onrequest)

Identification of the groups:

1 pair black, white1 triad black, white, red1 quad black, white, red, green

Special cable properties:

Fire propagation: IEC 60332-3 category “A”, “A/F”Fire resistance: IEC 60331 950 °CSmoke: IEC 61034-1/2, MIL-C-24643A

(par. 4.7.27) and NES 711Acidity: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.25)Halogen content: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.26)Toxicity index: NES 713Cold properties: cold bend (–40 °C) and cold impact

(–35 °C) according to CAN/CSA-C22.2No. 0.3-Dec. ’92

*Remark: Other constructions available on request.

Instrumentation and communication cablesHXXMB-FR EEP 0.6/1 kV IEC 60092-3

Overall shielded*

Opmaak Control Cables 27-07-2001 15:17 Pagina 18

198

Page 206: Prysmian Draka - Marine & Offshore LV HV Cables

19

General data for HXXMB-FR Overall shielded EEP 0.6/1 kV IEC 60092-3

number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductorcores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistancenominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 °C DC at 20 °C DCsectional area class 2 sheath sheath wire(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M’) (kg/km) (Ω/M’) (Ω/km)

1 x 2 x 1 7 1.3 3.8 0.406 10.3 0.32 0.559 14.2 85 195 290 5.6 18.51 x 3 x 1 7 1.3 3.8 0.429 10.9 0.32 0.583 14.8 89 215 320 5.6 18.5

1 x 2 x 1.5 7 1.6 4.1 0.429 10.9 0.32 0.579 14.7 88 208 310 3.7 12.31 x 3 x 1.5 7 1.6 4.1 0.461 11.7 0.32 0.614 15.6 94 249 370 3.7 12.31 x 4 x 1.5 7 1.6 4.1 0.504 12.8 0.32 0.665 16.9 101 280 416 3.7 12.3

1 x 2 x 2.5 7 2.0 4.5 0.472 12.0 0.32 0.622 15.8 95 269 400 2.30 7.56

Electrical characteristics for HXXMB-FR Overall shielded EEP 0.6/1 kV IEC 60092-3,cross section of mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductance loop inductance loop inductancethe conductor core to core (nF/M’) core to core (nF/km) core to shield (nF/M’) core to shield (nF/km) (mH/M’) (mH/km) (mH/M’) mH/km)(mm2) pair, triad & quad pair, triad & quad pair, triad & quad pair, triad & quad pair & triad pair & triad quad quad1 20 66 35 115 0.24 0.80 - -1.5 22 73 38 124 0.23 0.76 0.27 0.902.5 25 82 42 138 0.21 0.70 - -

Opmaak Control Cables 27-07-2001 15:17 Pagina 19

199

Page 207: Prysmian Draka - Marine & Offshore LV HV Cables

28

Application:

Armored, individually shielded and isolated instrumen-tation and communication cables 0.6/1 k V with specialproperties for electrical installations in ships and offshoreunits. Temperature Class 85 °C, Flame Retardant (IEC 60332-3 category “A”, “A/F”), Low Smoke, HalogenFree, Low Toxicity. Suitable for application in cold climateareas required to pass cold bend and cold impact testingat –40 °C and –35 °C, respectively.

Construction:

According to IEC 60092-3 with enhanced properties.

Conductors: stranded bare annealedcopper, IEC 60228, sizes 1 - 4 mm2

Insulation: cross linked polyethylene (XLPE/HF XLPE) according to IEC 60092-3,IEC 60092-351 and IEEE Std 45

Twisting: cores twisted to a pair/triadIndividual shield tinned copper drain wire; alumi- and isolation: num/polyester tape; polyester tapeAssembly: shielded pairs/triads cabled togetherInnersheath: halogen free, flame retardant

(SHF1, IEC 60092-359)Braiding: bronze wires according to IEEE

Std 45, CDA 220, weight coverage90% on nominal diameter accordingto IEC 60092-3, wire diameter 0.32 - 0.40 mm

Sheathing: halogen free, flame retardant(SHF1, IEC 60092-359); all sheath andjacketing materials shall pass tearresistance testing to 35 lbs/in(6.4 N/mm)

Sheathing color: gray (other colors are available onrequest)

Identification of the groups:

1 pair black, whitemulti pairs black, white

(groups sequential cores numbered1-1, 2-2, 3-3 etc.)

1 triad black, white, redmulti triads black, white, red

(groups sequential cores numbered1-1-1, 2-2-2, 3-3-3, etc.)

Special cable properties:

Fire propagation: IEC 60332-3 category “A”, “A/F”Smoke: IEC 61034-1/2, MIL-C-24643A

(par. 4.7.27) and NES 711Acidity: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.25)Halogen content: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.26)Toxicity index: NES 713Cold properties: cold bend (–40 °C) and cold impact

(–35 °C) according to CAN/CSA-C22.2No. 0.3-Dec. ’92

*Remark: Other constructions available on request

Instrumentation and communication cablesHXXMB EEP 0.6/1 kV IEC 60092-3

Individually shielded and isolated*

Opmaak Control Cables 27-07-2001 15:18 Pagina 22

200

Page 208: Prysmian Draka - Marine & Offshore LV HV Cables

29

General data for HXXMB Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3

number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductorcores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistancenominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 °C DC at 20 °C DCsectional area class 2 sheath sheath wire(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M’) (kg/km) (Ω/M’) (Ω/km)

1 x 2 x 1 7 1.3 3.1 0.350 8.9 0.32 0.500 12.7 76 161 240 5.6 18.52 x 2 x 1 7 1.3 3.1 0.567 14.4 0.32 0.728 18.5 111 323 480 5.6 18.54 x 2 x 1 7 1.3 3.1 0.673 17.1 0.32 0.843 21.4 128 383 570 5.6 18.5

10 x 2 x 1 7 1.3 3.1 0.984 25.0 0.32 1.177 29.9 179 766 1,140 5.6 18.512 x 2 x 1 7 1.3 3.1 1.047 26.6 0.32 1.240 31.5 189 806 1,200 5.6 18.516 x 2 x 1 7 1.3 3.1 1.185 30.1 0.32 1.386 35.2 211 1,008 1,500 5.6 18.5

1 x 2 x 1.5 7 1.6 3.4 0.370 9.4 0.32 0.524 13.3 80 148 220 3.7 12.32 x 2 x 1.5 7 1.6 3.4 0.606 15.4 0.32 0.768 19.5 117 363 540 3.7 12.35 x 2 x 1.5 7 1.6 3.4 0.799 20.3 0.32 0.969 25.7 148 484 720 3.7 12.3

12 x 2 x 1.5 7 1.6 3.4 1.130 28.7 0.32 1.331 33.8 203 927 1,380 3.7 12.3

12 x 2 x 2.5 7 2.0 3.8 1.272 32.3 0.40 1.484 37.7 226 1,075 1,600 2.30 7.56

2 x 2 x 4 7 2.5 4.6 0.787 20.0 0.32 0.957 24.3 146 491 730 1.43 4.70

1 x 3 x 1 7 1.3 3.1 0.370 9.4 0.32 0.524 13.3 80 343 510 5.6 18.5

1 x 3 x 1.5 7 1.6 3.4 0.394 10.0 0.32 0.543 13.8 83 349 520 3.7 12.310 x 3 x 1.5 7 1.6 3.4 1.240 31.5 0.40 1.453 36.9 221 1,062 1,580 3.7 12.316 x 3 x 1.5 7 1.6 3.4 1.499 36.8 0.40 1.677 42.6 256 1,378 2,050 3.7 12.3

Electrical characteristics for HXXMB Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3

cross section of the mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductanceconductor core to core (nF/M’) core to core (nF/km) core to shield (nF/M’) core to shield (nF/km) (mH/M’) (mH/km)(mm2) pair & triad pair & triad pair & triad pair & triad pair & triad pair & triad

1 19 63 33 108 0.22 0.721.5 21 70 37 121 0.21 0.682.5 24 79 41 136 0.20 0.644 25 82 43 142 0.19 0.62

Opmaak Control Cables 27-07-2001 15:18 Pagina 23

201

Page 209: Prysmian Draka - Marine & Offshore LV HV Cables

22

Application:

Armored, individually shielded and isolated instrumen-tation and communication cables 250 V with specialproperties for electrical installations in ships and offshoreunits. Temperature Class 85 °C, Flame Retardant (IEC 60332-3 category “A”, “A/F”), Low Smoke, HalogenFree, Low Toxicity. Suitable for application in cold climateareas required to pass cold bend and cold impact testingat –40 °C and –35 °C, respectively.

Construction:

According to IEC 60092-3 with enhanced properties.

Conductors: stranded bare annealedcopper, IEC 60228, sizes 1 - 4 mm2

Insulation: cross linked polyethylene (XLPE/HF XLPE) according to IEC 60092-3,IEC 60092-351 and IEEE Std 45

Twisting: cores twisted to a pair/triadIndividual shield tinned copper drain wire; alumi- and isolation: num/polyester tape; polyester tapeAssembly: shielded pairs/triads cabled togetherInnersheath: halogen free, flame retardant

(SHF1, IEC 60092-359)Braiding: bronze wires according to IEEE

Std 45, CDA 220, weight coverage90% on nominal diameter accordingto IEC 60092-3, wire diameter 0.32 - 0.40 mm

Sheathing: halogen free, flame retardant(SHF1, IEC 60092-359); all sheath andjacketing materials shall pass tearresistance testing to 35 lbs/in(6.4 N/mm)

Sheathing color: gray (other colors are available onrequest)

Identification of the groups:

1 pair black, whitemulti pairs black, white

(groups sequential cores numbered1-1, 2-2, 3-3 etc.)

1 triad black, white, redmulti triads black, white, red

(groups sequential cores numbered1-1-1, 2-2-2, 3-3-3, etc.)

Special cable properties:

Fire propagation: IEC 60332-3 category “A”, “A/F”Smoke: IEC 61034-1/2, MIL-C-24643A

(par. 4.7.27) and NES 711Acidity: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.25)Halogen content: IEC 60754-1/2 and MIL-C-24643A

(par. 4.7.26)Toxicity index: NES 713Cold properties: cold bend (–40 °C) and cold impact

(–35 °C) according to CAN/CSA-C22.2No. 0.3-Dec. ’92

*Remark: Other constructions available on request

Instrumentation and communication cablesHXXMB EEP 250 V IEC 60092-3

Individually shielded and isolated*

Opmaak Control Cables 27-07-2001 15:18 Pagina 22

202

Page 210: Prysmian Draka - Marine & Offshore LV HV Cables

23

General data for HXXMB Individually shielded and isolated EEP 250V IEC 60092-3

number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductorcores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistancenominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 °C DC at 20 °C DCsectional area class 2 sheath sheath wire(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M’) (kg/km) (Ω/M’) (Ω/km)

1 x 2 x 1 7 1.3 3.1 0.350 8.9 0.32 0.500 12.7 76 161 240 5.6 18.52 x 2 x 1 7 1.3 3.1 0.567 14.4 0.32 0.728 18.5 111 323 480 5.6 18.54 x 2 x 1 7 1.3 3.1 0.673 17.1 0.32 0.843 21.4 128 383 570 5.6 18.5

10 x 2 x 1 7 1.3 3.1 0.984 25.0 0.32 1.177 29.9 179 766 1,140 5.6 18.512 x 2 x 1 7 1.3 3.1 1.047 26.6 0.32 1.240 31.5 189 806 1,200 5.6 18.516 x 2 x 1 7 1.3 3.1 1.185 30.1 0.32 1.386 35.2 211 1,008 1,500 5.6 18.5

1 x 2 x 1.5 7 1.6 3.4 0.370 9.4 0.32 0.524 13.3 80 148 220 3.7 12.32 x 2 x 1.5 7 1.6 3.4 0.606 15.4 0.32 0.768 19.5 117 363 540 3.7 12.35 x 2 x 1.5 7 1.6 3.4 0.799 20.3 0.32 0.969 24.6 148 484 720 3.7 12.3

12 x 2 x 1.5 7 1.6 3.4 1.130 28.7 0.32 1.331 33.8 203 927 1,380 3.7 12.3

12 x 2 x 2.5 7 2.0 3.8 1.272 32.3 0.40 1.484 37.7 226 1,075 1,600 2.30 7.56

2 x 2 x 4 7 2.5 4.6 0.787 20.0 0.32 0.957 24.3 146 491 730 1.43 4.70

1 x 3 x 1 7 1.3 3.1 0.370 9.4 0.32 0.524 13.3 80 343 510 5.6 18.5

1 x 3 x 1.5 7 1.6 3.4 0.394 10.0 0.32 0.543 13.8 83 349 520 3.7 12.310 x 3 x 1.5 7 1.6 3.4 1.240 31.5 0.40 1.453 36.9 221 1,062 1,580 3.7 12.316 x 3 x 1.5 7 1.6 3.4 1.499 36.8 0.40 1.677 42.6 256 1,378 2,050 3.7 12.3

Electrical characteristics for HXXMB Individually shielded and isolated EEP 250 V IEC 60092-3

cross section of the mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductanceconductor core to core (nF/M’) core to core (nF/km) core to shield (nF/M’) core to shield (nF/km) (mH/M’) (mH/km)(mm2) pair & triad pair & triad pair & triad pair & triad pair & triad pair & triad

1 19 63 33 108 0.22 0.721.5 21 70 37 121 0.21 0.682.5 24 79 41 136 0.20 0.644 25 82 43 142 0.19 0.62

Opmaak Control Cables 27-07-2001 15:18 Pagina 23

203

Page 211: Prysmian Draka - Marine & Offshore LV HV Cables

26

Application:

Armored, individually shielded and isolated fire resistantinstrumentation and communication cables 0.6/1 kV withspecial properties for electrical installations in ships andoffshore units. Temperature Class 85 °C, Flame Retardant (IEC 60332-3 category “A/F”), Low Smoke, Halogen Free,Low Toxicity and Fire Resistant (IEC 60331 950 °C). Suitablefor application in cold climate areas required to pass coldbend and cold impact testing at –40 °C and –35 °C, respectively.

Construction:

According to IEC 60092-3 with enhanced properties.

Conductors: stranded bare annealedcopper, IEC 60228, sizes 1 to 4 mm2

Insulation: mica tape, and cross linked polyethy-lene (XLPE/HF XLPE) according toIEC 60092-3, IEC 60092-351 andIEEE Std 45

Twisting: cores twisted to a pair/triad/quadIndividual shield tinned copper drain wire; alumi-and isolation: num/polyester tape; polyester tapeAssembly: shielded pairs/triads/quads cabled

togetherInnersheath: halogen free, flame retardant

(SHF1, IEC 60092-359)Braiding: bronze wires according to IEEE

Std 45, CDA 220, weight coverage90% on nominal diameter accordingto IEC 60092-3, wire diameter 0.32 - 0.40 mm

Sheathing: halogen free, flame retardant(SHF1, IEC 60092-359); all sheath andjacketing materials shall pass tearresistance testing to 35 lbs/in(6.4 N/mm)

Sheathing color: gray (other colors are available onrequest)

Identification of the groups:

1 pair black, whitemulti pairs black, white

(groups sequential numbered1-1, 2-2, 3-3 etc.)

1 triad black, white, redmulti triads black, white, red

(groups sequential numbered1-1-1, 2-2-2, 3-3-3 etc.)

Special cable properties:

Fire propagation: IEC 60332-3 category “A”, “A/F”Fire resistance: IEC 60331 950 °CSmoke: IEC 61034-1/2, MIL-C-24643A (par. 4.7.27) and

NES 711Acidity: IEC 60754-1/2 and MIL-C-24643A (par. 4.7.25)Halogen content: IEC 60754-1/2 and MIL-C-24643A (par. 4.7.26)Toxicity index: NES 713Cold properties: cold bend (–40 °C) and cold impact (–35 °C)

according to CAN/CSA-C22.2 No. 0.3-Dec. ’92

*Remark: Other constructions available on request

Instrumentation and communication cablesHXXMB-FR EEP 0.6/1 kV IEC 60092-3

Individually shielded and isolated*

Opmaak Control Cables 27-07-2001 15:18 Pagina 20

204

Page 212: Prysmian Draka - Marine & Offshore LV HV Cables

27

General data for HXXMB-FR Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3

number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductorcores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistancenominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 °C DC at 20 °C DCsectional area class 2 sheath sheath wire(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M’) (kg/km) (Ω/M’) (Ω/km)

1 x 2 x 1 7 1.3 3.8 0.406 10.3 0.32 0.559 14.2 85 195 290 5.6 18.52 x 2 x 1 7 1.3 3.8 0.677 17.2 0.32 0.846 21.5 129 390 580 5.6 18.54 x 2 x 1 7 1.3 3.8 0.799 20.3 0.32 0.969 24.6 148 484 720 5.6 18.57 x 2 x 1 7 1.3 3.8 0.909 23.1 0.32 1.087 27.6 166 625 930 5.6 18.58 x 2 x 1 7 1.3 3.8 1.004 25.5 0.32 1.189 30.2 181 739 1,100 5.6 18.5

10 x 2 x 1 7 1.3 3.8 1.177 29.9 0.40 1.390 35.3 212 1,008 1,500 5.6 18.512 x 2 x 1 7 1.3 3.8 1.264 32.1 0.40 1.476 37.5 225 1,075 1,600 5.6 18.516 x 2 x 1 7 1.3 3.8 1.429 36.3 0.40 1.650 41.9 251 1,344 2,000 5.6 18.519 x 3 x 1 7 1.3 3.8 1.465 37.2 0.40 1.693 43.0 258 1,411 2,100 5.6 18.5

1 x 2 x 1.5 7 1.6 4.1 0.429 10.9 0.32 0.579 14.7 88 208 310 3.7 12.32 x 2 x 1.5 7 1.6 4.1 0.717 18.2 0.32 0.882 22.4 134 423 630 3.7 12.34 x 2 x 1.5 7 1.6 4.1 0.846 21.5 0.32 1.024 26.0 156 551 820 3.7 12.35 x 2 x 1.5 7 1.6 4.1 0.945 24.0 0.32 1.122 28.5 171 645 960 3.7 12.38 x 2 x 1.5 7 1.6 4.1 1.063 27.0 0.32 1.248 31.7 190 796 1,185 3.7 12.3

12 x 2 x 1.5 7 1.6 4.1 1.350 34.3 0.40 1.571 39.9 239 1,243 1,850 3.7 12.3

1 x 2 x 2.5 7 2.0 4.5 0.472 12.0 0.32 0.622 15.8 95 269 400 2.30 7.5612 x 2 x 2.5 7 2.0 4.5 1.480 37.6 0.40 1.709 43.4 260 1,411 2,100 2.30 7.56

2 x 2 x 4 7 2.5 5.3 0.898 22.8 0.32 1.075 27.3 164 605 900 1.43 4.70

1 x 3 x 1 7 1.3 3.8 0.429 10.9 0.32 0.583 14.8 89 215 320 5.6 18.54 x 3 x 1 7 1.3 3.8 0.909 23.1 0.32 1.087 27.6 166 591 880 5.6 18.5

1 x 3 x 1.5 7 1.6 4.1 0.461 11.7 0.32 0.614 15.6 94 249 370 3.7 12.310 x 3 x 1.5 7 1.6 4.1 1.469 37.3 0.40 1.697 43.1 259 1,478 2,200 3.7 12.316 x 3 x 1.5 7 1.6 4.1 1.819 46.2 0.40 2.063 52.4 314 1,781 2,650 3.7 12.3

Electrical characteristics for HXXMB-FR Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3

cross section of the mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductanceconductor core to core (nF/M’) core to core (nF/km) core to shield (nF/M’) core to shield (nF/km) (mH/M’) (mH/km)(mm2) pair & triad pair & triad pair & triad pair & triad pair & triad pair & triad

1 20 66 35 115 0.24 0.801.5 22 73 38 124 0.23 0.762.5 25 82 42 138 0.21 0.704 26 84 43 141 0.21 0.68

Opmaak Control Cables 27-07-2001 15:18 Pagina 21

205

Page 213: Prysmian Draka - Marine & Offshore LV HV Cables

20

Application:

Armored, individually shielded and isolated fire resistantinstrumentation and communication cables 250 V withspecial properties for electrical installations in ships andoffshore units. Temperature Class 85 °C, Flame Retardant (IEC 60332-3 category “A/F”), Low Smoke, Halogen Free,Low Toxicity and Fire Resistant (IEC 60331 950 °C). Suitablefor application in cold climate areas required to pass coldbend and cold impact testing at –40 °C and –35 °C, respectively.

Construction:

According to IEC 60092-3 with enhanced properties.

Conductors: stranded bare annealedcopper, IEC 60228, sizes 1 to 4 mm2

Insulation: mica tape, and cross linked polyethy-lene (XLPE/HF XLPE) according toIEC 60092-3, IEC 60092-351 andIEEE Std 45

Twisting: cores twisted to a pair/triad/quadIndividual shield tinned copper drain wire; alumi-and isolation: num/polyester tape; polyester tapeAssembly: shielded pairs/triads/quads cabled

togetherInnersheath: halogen free, flame retardant

(SHF1, IEC 60092-359)Braiding: bronze wires according to IEEE

Std 45, CDA 220, weight coverage90% on nominal diameter accordingto IEC 60092-3, wire diameter 0.32 - 0.40 mm

Sheathing: halogen free, flame retardant(SHF1, IEC 60092-359); all sheath andjacketing materials shall pass tearresistance testing to 35 lbs/in(6.4 N/mm)

Sheathing color: gray (other colors are available onrequest)

Identification of the groups:

1 pair black, whitemulti pairs black, white

(groups sequential numbered1-1, 2-2, 3-3 etc.)

1 triad black, white, redmulti triads black, white, red

(groups sequential numbered1-1-1, 2-2-2, 3-3-3 etc.)

1 quad black, white, red, green

Special cable properties:

Fire propagation: IEC 60332-3 category “A”, “A/F”Fire resistance: IEC 60331 950 °CSmoke: IEC 61034-1/2, MIL-C-24643A (par. 4.7.27) and

NES 711Acidity: IEC 60754-1/2 and MIL-C-24643A (par. 4.7.25)Halogen content: IEC 60754-1/2 and MIL-C-24643A (par. 4.7.26)Toxicity index: NES 713Cold properties: cold bend (–40 °C) and cold impact (–35 °C)

according to CAN/CSA-C22.2 No. 0.3-Dec. ’92

*Remark: Other constructions available on request

Instrumentation and communication cablesHXXMB-FR EEP 250 V IEC 60092-3

Individually shielded and isolated*

Opmaak Control Cables 27-07-2001 15:18 Pagina 20

206

Page 214: Prysmian Draka - Marine & Offshore LV HV Cables

21

General data for HXXMB-FR Individually shielded and isolated EEP 250 V IEC 60092-3

number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductorcores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistancenominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 °C DC at 20 °C DCsectional area class 2 sheath sheath wire(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M’) (kg/km) (Ω/M’) (Ω/km)

1 x 2 x 1 7 1.3 3.8 0.406 10.3 0.32 0.559 14.2 85 195 290 5.6 18.52 x 2 x 1 7 1.3 3.8 0.677 17.2 0.32 0.846 21.5 129 390 580 5.6 18.54 x 2 x 1 7 1.3 3.8 0.799 20.3 0.32 0.969 24.6 148 484 720 5.6 18.57 x 2 x 1 7 1.3 3.8 0.909 23.1 0.32 1.087 27.6 166 625 930 5.6 18.58 x 2 x 1 7 1.3 3.8 1.004 25.5 0.32 1.189 30.2 181 739 1,100 5.6 18.5

10 x 2 x 1 7 1.3 3.8 1.177 29.9 0.40 1.390 35.3 212 1,008 1,500 5.6 18.512 x 2 x 1 7 1.3 3.8 1.264 32.1 0.40 1.476 37.5 225 1,075 1,600 5.6 18.516 x 2 x 1 7 1.3 3.8 1.429 36.3 0.40 1.650 41.9 251 1,344 2,000 5.6 18.519 x 3 x 1 7 1.3 3.8 1.465 37.2 0.40 1.693 43.0 258 1,411 2,100 5.6 18.5

1 x 2 x 1.5 7 1.6 4.1 0.429 10.9 0.32 0.579 14.7 88 208 310 3.7 12.32 x 2 x 1.5 7 1.6 4.1 0.717 18.2 0.32 0.882 22.4 134 423 630 3.7 12.34 x 2 x 1.5 7 1.6 4.1 0.846 21.5 0.32 1.024 26.0 156 551 820 3.7 12.35 x 2 x 1.5 7 1.6 4.1 0.945 24.0 0.32 1.122 28.5 171 645 960 3.7 12.38 x 2 x 1.5 7 1.6 4.1 1.063 27.0 0.32 1.248 31.7 190 796 1,185 3.7 12.3

12 x 2 x 1.5 7 1.6 4.1 1.350 34.3 0.40 1.571 39.9 239 1,243 1,850 3.7 12.3

1 x 2 x 2.5 7 2.0 4.5 0.472 12.0 0.32 0.622 15.8 95 269 400 2.30 7.5612 x 2 x 2.5 7 2.0 4.5 1.480 37.6 0.40 1.709 43.4 260 1,411 2,100 2.30 7.56

2 x 2 x 4 7 2.5 5.3 0.898 22.8 0.32 1.075 27.3 164 605 900 1.43 4.70

1 x 3 x 1 7 1.3 3.8 0.429 10.9 0.32 0.583 14.8 89 215 320 5.6 18.54 x 3 x 1 7 1.3 3.8 0.909 23.1 0.32 1.087 27.6 166 591 880 5.6 18.5

1 x 3 x 1.5 7 1.6 4.1 0.461 11.7 0.32 0.614 15.6 94 249 370 3.7 12.310 x 3 x 1.5 7 1.6 4.1 1.469 37.3 0.40 1.697 43.1 259 1,478 2,200 3.7 12.316 x 3 x 1.5 7 1.6 4.1 1.819 46.2 0.40 2.063 52.4 314 1,781 2,650 3.7 12.3

Electrical characteristics for HXXMB-FR Individually shielded and isolated EEP 250 V IEC 60092-3

cross section of the mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductanceconductor core to core (nF/M’) core to core (nF/km) core to shield (nF/M’) core to shield (nF/km) (mH/M’) (mH/km)(mm2) pair & triad pair & triad pair & triad pair & triad pair & triad pair & triad

1 20 66 35 115 0.24 0.801.5 22 73 38 124 0.23 0.762.5 25 82 42 138 0.21 0.704 26 84 43 141 0.21 0.68

Opmaak Control Cables 27-07-2001 15:18 Pagina 21

207

Page 215: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU 1kV(4).doc 03/06/2008 09:00:00

Page 1 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable

www.drakaMOG.com Subject to change without prior notice

Fire resistant, flame retardant halogen-free power cable. Mud resistant

BFOU 0,6/1kV MGT/EPR/EPR/TCWB/EVA NEK 606 CodeP5/P12 Operating temperature : 90°C Operating Voltage : 0,6/1kV

Application Fixed installation for power, control and lighting in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK 606.

Standards applied

IEC 60092-353 - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60331-21 - Fire Resistant IEC 60754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner covering

PET tape

Armour/screen O Tinned annealed copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "år" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX - FLAME IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229

Manufacturing unit DRAKA 01 = Draka Norsk Kabel Outer sheath colour Black

208

Page 216: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU 1kV(4).doc 03/06/2008 09:00:00

Page 2 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable

www.drakaMOG.com Subject to change without prior notice

Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 16 4 5.15 1.0 1.1 10 ± 0.8 0.2 1.2 13 ± 0.8 370 198

1 25 6 6.45 1.2 1.1 11.5 ± 0.8 0.3 1.3 15.5 ±

0.8 530 314

1 50 10 9.0 1.4 1.1 15 ± 0.8 0.3 1.4 18.5 ± 0.8 870 555

1 70 10 10.85 1.4 1.1 16.5 ± 0.8 0.3 1.4 20.5 ± 1 1110 744

1 95 10 12.60 1.6 1.1 18.5 ± 0.8 0.3 1.5 23 ± 1 1420 985

1 120 10 14.20 1.6 1.2 20.5 ± 1 0.3 1.6 25 ± 1 1730 1224 1 150 10 15.90 1.8 1.2 23 ± 1 0.3 1.7 27.5 ± 1 2100 1510 1 185 10 17.70 2.0 1.2 25 ± 1 0.3 1.7 29.5 ± 1 2500 1837 1 240 16 20.15 2.2 1.2 28 ± 1 0.3 1.8 33 ± 1.5 3170 2371 1 300 16 22.60 2.4 1.2 31 ± 1.5 0.3 1.9 36 ± 1.5 3890 2975 2 1.5 4 1.6 1.0 1.1 10 ± 0.8 0.2 1.2 13 ± 0.8 285 80

3G 1.5 - 1.6 1.0 1.1 10.5 ± 0.8 0.3 1.3 14.5 ±

0.8 360 125

4G 1.5 - 1.6 1.0 1.1 11.5 ± 0.8 0.3 1.3 15.5 ±

0.8 420 156

3 1.5 6 1.6 1.0 1.1 10.5 ± 0.8 0.3 1.3 14.5 ±

0.8 360 125

4 1.5 6 1.6 1.0 1.1 11.5 ± 0.8 0.3 1.3 15.5 ±

0.8 420 156

5 1.5 6 1.6 1.0 1.1 13 ± 0.8 0.3 1.4 16.5 ± 0.8 480 170

7 1.5 6 1.6 1.0 1.1 14 ± 0.8 0.3 1.4 18 ± 0.8 560 214

12 1.5 10 1.6 1.0 1.2 18.5 ± 0.8 0.3 1.6 23 ± 1 830 316

19 1.5 10 1.6 1.0 1.2 22 ± 1 0.3 1.7 26.5 ± 1 1130 438

27 1.5 16 1.6 1.0 1.2 26.5 ± 1 0.3 1.9 31.5 ± 1.5 1500 574

37 1.5 16 1.6 1.0 1.4 30 ± 1.5 0.3 2 35.5 ± 1.5 1950 741

5G 1.5 - 1.6 1.0 1.1 13 ± 0.8 0.3 1.4 16.5 ± 0.8 480 170

32 1.5 16 1.6 1.0 1.4 29 ± 1 0.3 2 34.5 ± 1.5 1800 668

7G 2.5 - 2.0 1.0 1.1 15 ± 0.8 0.3 1.4 19 ± 0.8 650 276

2 2.5 6 2.0 1.0 1.1 11 ± 0.8 0.3 1.3 14.5 ± 0.8 370 129

3G 2.5 - 2.0 1.0 1.1 11.5 ± 0.3 1.3 15 ± 0.8 420 169

209

Page 217: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU 1kV(4).doc 03/06/2008 09:00:00

Page 3 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable

www.drakaMOG.com Subject to change without prior notice

Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

0.8

3 2.5 6 2.0 1.0 1.1 11.5 ± 0.8 0.3 1.3 15 ± 0.8 420 169

4G 2.5 - 2.0 1.0 1.1 12.5 ± 0.8 0.3 1.3 16.5 ±

0.8 480 192

4 2.5 6 2.0 1.0 1.1 12.5 ± 0.8 0.3 1.3 16.5 ±

0.8 480 192

8G 2.5 - 2.0 1.0 1.1 19.5 ± 0.8 0.3 1.5 23.5 ± 1 790 332

7 2.5 6 2.0 1.0 1.1 15 ± 0.8 0.3 1.4 19 ± 0.8 650 277 12 2.5 10 2.0 1.0 1.2 20.5 ± 1 0.3 1.6 24.5 ± 1 990 425 19 2.5 10 2.0 1.0 1.2 24 ± 1 0.3 1.8 28.5 ± 1 1380 611

27 2.5 16 2.0 1.0 1.4 29.5 ± 1 0.3 2 34.5 ± 1.5 1920 844

37 2.5 25 2.0 1.0 1.4 33 ± 1.5 0.4 2.2 39 ± 1.5 2570 1200 5G 2.5 - 2.0 1.0 1.1 14 ± 0.8 0.3 1.4 18 ± 0.8 570 231 4G 4 - 2.55 1.0 1.1 14 ± 0.8 0.3 1.4 18 ± 0.8 610 263

5G 4 - 2.55 1.0 1.1 15.5 ± 0.8 0.3 1.4 19.5 ±

0.8 700 299

2 4 6 2.55 1.0 1.1 12 ± 0.8 0.3 1.3 15.5 ± 0.8 450 173

3 4 6 2.55 1.0 1.1 13 ± 0.8 0.3 1.3 16.5 ± 0.8 510 210

4 4 6 2.55 1.0 1.1 14 ± 0.8 0.3 1.4 18 ± 0.8 610 263

3G 4 - 2.55 1.0 1.1 13 ± 0.8 0.3 1.3 16.5 ± 0.8 510 210

2 6 6 3.15 1.0 1.1 13 ± 0.8 0.3 1.4 17 ± 0.8 530 209 3 6 6 3.15 1.0 1.1 14 ± 0.8 0.3 1.4 18 ± 0.8 620 280

4 6 6 3.15 1.0 1.1 15.5 ± 0.8 0.3 1.4 19.5 ±

0.8 720 334

3G 6 - 3.15 1.0 1.1 14 ± 0.8 0.3 1.4 18 ± 0.8 620 280

4G 6 - 3.15 1.0 1.1 15.5 ± 0.8 0.3 1.4 19.5 ±

0.8 720 334

5G 6 - 3.15 1.0 1.1 17 ± 0.8 0.3 1.5 21.5 ± 1 880 405 2 10 10 4.05 1.0 1.1 15 ± 0.8 0.3 1.4 19 ± 0.8 680 298 3 10 10 4.05 1.0 1.1 16 ± 0.8 0.3 1.5 20 ± 1 800 389 4 10 10 4.05 1.0 1.1 18 ± 0.8 0.3 1.5 22 ± 1 960 496 3G 10 - 4.05 1.0 1.1 16 ± 0.8 0.3 1.5 20 ± 1 800 387 4G 10 - 4.05 1.0 1.1 18 ± 0.8 0.3 1.5 22 ± 1 960 494 5G 10 - 4.05 1.0 1.2 20 ± 1 0.3 1.6 24 ± 1 1170 600

2 16 16 5.15 1.0 1.1 17.5 ± 0.8 0.5 1.5 22 ± 1 990 497

3 16 16 5.15 1.0 1.1 18.5 ± 0.8 0.4 1.5 23 ± 1 1170 654

4 16 16 5.15 1.0 1.2 20.5 ± 1 0.4 1.6 25.5 ± 1 1410 799

3G 16 - 5.15 1.0 1.1 18.5 ± 0.8 0.3 1.5 22.5 ± 1 1090 583

5G 16 - 5.15 1.0 1.2 23 ± 1 0.3 1.7 27.5 ± 1 1610 896 4G 16 - 5.15 1.0 1.2 20.5 ± 1 0.3 1.6 25 ± 1 1330 727 2 25 16 6.45 1.2 1.2 21 ± 1 0.4 1.6 26 ± 1 1370 685 3 25 16 6.45 1.2 1.2 22.5 ± 1 0.3 1.7 27 ± 1 1600 887 4 25 16 6.45 1.2 1.2 25 ± 1 0.3 1.8 29.5 ± 1 1950 1116 4G 25 - 6.45 1.2 1.2 25 ± 1 0.3 1.8 29.5 ± 1 1930 1091 5G 25 - 6.45 1.2 1.2 27.5 ± 1 0.3 1.8 32 ± 1.5 2290 1345 2 35 16 7.65 1.2 1.2 23.5 ± 1 0.3 1.7 28 ± 1 1630 818 3 35 16 7.65 1.2 1.2 25 ± 1 0.3 1.8 30 ± 1.5 1990 1125 4 35 16 7.65 1.2 1.2 28 ± 1 0.3 1.9 33 ± 1.5 2440 1434 3G 35 - 7.65 1.2 1.2 25 ± 1 0.3 1.8 30 ± 1.5 1970 1101

210

Page 218: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU 1kV(4).doc 03/06/2008 09:00:00

Page 4 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable

www.drakaMOG.com Subject to change without prior notice

Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

4G 35 - 7.65 1.2 1.2 28 ± 1 0.3 1.9 33 ± 1.5 2440 1434

5G 35 - 7.65 1.2 1.4 31 ± 1.5 0.3 2 36.5 ± 1.5 2980 1768

3 50 25 9.0 1.4 1.2 29 ± 1 0.4 1.9 34.5 ± 1.5 2710 1602

4 50 25 9.0 1.4 1.4 32.5 ± 1.5 0.4 2 38 ± 1.5 3350 2033

5G 50 - 9.0 1.4 1.4 36 ± 1.5 0.4 2.2 42 ± 2 4090 2508

4G 50 - 9.0 1.4 1.4 32.5 ± 1.5 0.3 2 38 ± 1.5 3260 1949

2 70 35 10.85 1.4 1.4 31 ± 1.5 0.6 2 37.5 ± 1.5 3120 1758

3 70 35 10.85 1.4 1.4 33 ± 1.5 0.5 2 39 ± 1.5 3730 2347 4 70 35 10.85 1.4 1.4 37 ± 1.5 0.4 2.2 43 ± 2 4550 2926 4G 70 - 10.85 1.4 1.4 37 ± 1.5 0.4 2.2 43 ± 2 4460 2839 5G 70 - 10.85 1.4 1.4 41 ± 2 0.4 2.3 47 ± 2 5380 3503 3 95 50 12.60 1.6 1.4 38 ± 1.5 0.6 2.2 44.5 ± 2 4910 3133 4 95 50 12.60 1.6 1.6 42.5 ± 2 0.5 2.4 49.5 ± 2 6090 3975 4G 95 - 12.60 1.6 1.6 42.5 ± 2 0.4 2.4 49 ± 2 5860 3748 5G 95 - 12.60 1.6 1.6 47 ± 2 0.4 2.6 54 ± 2.5 7080 4630 3 120 60 14.20 1.6 1.4 41 ± 2 0.6 2.4 48.5 ± 2 6000 3953

4 120 60 14.20 1.6 1.6 46 ± 2 0.6 2.5 53.5 ± 2.5 7430 5030

4G 120 - 14.20 1.6 1.6 46 ± 2 0.4 2.5 53 ± 2.5 7150 4754

4G 150 - 15.90 1.8 1.6 52 ± 2.5 0.5 2.7 59.5 ± 2.5 8810 5848

4G 185 - 17.70 2.0 1.8 57.5 ± 2.5 0.5 2.9 65.5 ± 3 10810 7248

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

800200 BFOU 0.6/1kV 1X 16/4mm² P5/P12 BLACK - 7021528002003 1043605 800201 BFOU 0.6/1kV 1X 25/6mm² P5/P12 BLACK - 7021528002010 - 800203 BFOU 0.6/1kV 1X 50/6mm² P5/P12 BLACK Yes 7021528002034 1043608 800204 BFOU 0.6/1kV 1X 70/6mm² P5/P12 BLACK - 7021528002041 1043609 800205 BFOU 0.6/1kV 1X 95/10 P5/P12 BLACK Yes 7021528002058 1043610 800206 BFOU 0.6/1kV 1X 120/10 P5/P12 BLACK - 7021528002065 1043611 800207 BFOU 0.6/1kV 1X 150/10 P5/P12 BLACK Yes 7021528002072 1043612 800208 BFOU 0.6/1kV 1X 185/10 P5/P12 BLACK - 7021528002089 1043613 800209 BFOU 0.6/1kV 1X 240/16 P5/P12 BLACK - 7021528002096 - 800210 BFOU 0.6/1kV 1X 300/16 P5/P12 BLACK Yes 7021528002102 1043615 800215 BFOU 0.6/1kV 2X 1.5/4 P5/P12 BLACK Yes 7021528002157 1043620 800216 BFOU 0.6/1kV 3G 1.5mm² P5/P12 BLACK - 7021528002164 1043619 800217 BFOU 0.6/1kV 4G 1.5mm² P5/P12 BLACK - 7021528002171 - 800218 BFOU 0.6/1kV 3X 1.5/6 P5/P12 BLACK Yes 7021528002188 1043640 800219 BFOU 0.6/1kV 4X 1.5/6 P5/P12 BLACK Yes 7021528002195 1043660 800220 BFOU 0.6/1kV 5X 1.5/6 P5/P12 BLACK - 7021528002201 1043705 800221 BFOU 0.6/1kV 7X 1.5/6 P5/P12 BLACK Yes 7021528002218 1043707 800222 BFOU 0.6/1kV 12X 1.5/10 P5/P12 BLACK Yes 7021528002225 1043712 800223 BFOU 0.6/1kV 19X 1.5/10 P5/P12 BLACK Yes 7021528002232 1043719 800224 BFOU 0.6/1kV 27X 1.5/16 P5/P12 BLACK - 7021528002249 1043727 800225 BFOU 0.6/1kV 37X 1.5/16 P5/P12 BLACK - 7021528002256 - 800226 BFOU 0.6/1kV 5G 1.5mm² P5/P12 BLACK - 7021528002263 - 800227 BFOU 0.6/1kV 32X 1.5/16 P5/P12 BLACK - 7021528002270 - 800228 BFOU 0.6/1kV 7G 2.5mm² P5/P12 BLACK - 7021528002287 - 800229 BFOU 0.6/1kV 2X 2.5/6 P5/P12 BLACK Yes 7021528002294 1043621 800230 BFOU 0.6/1kV 3G 2.5mm² P5/P12 BLACK Yes 7021528002300 1043639

211

Page 219: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU 1kV(4).doc 03/06/2008 09:00:00

Page 5 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable

www.drakaMOG.com Subject to change without prior notice

Part number Description Sheath Colour Stock item EAN No. DNK EL No. 800232 BFOU 0.6/1kV 3X 2.5/6 P5/P12 BLACK Yes 7021528002324 1043641 800233 BFOU 0.6/1kV 4G 2.5mm² P5/P12 BLACK - 7021528002331 1043659 800235 BFOU 0.6/1kV 4X 2.5/6 P5/P12 BLACK Yes 7021528002355 1043661 800236 BFOU 0.6/1kV 8G 2.5mm² P5/P12 BLACK - 7021528002362 - 800237 BFOU 0.6/1kV 7X 2.5/6 P5/P12 BLACK Yes 7021528002379 1043757 800238 BFOU 0.6/1kV 12X 2.5/10 P5/P12 BLACK Yes 7021528002386 1043762 800239 BFOU 0.6/1kV 19X 2.5/10 P5/P12 BLACK - 7021528002393 1043769 800240 BFOU 0.6/1kV 27X 2.5/16 P5/P12 BLACK - 7021528002409 1043777 800241 BFOU 0.6/1kV 37X 2.5/25 P5/P12 BLACK - 7021528002416 1043787 800242 BFOU 0.6/1kV 5G 2.5mm² P5/P12 BLACK - 7021528002423 1043755 800243 BFOU 0.6/1kV 4G 4mm² P5/P12 BLACK - 7021528002430 - 800244 BFOU 0.6/1kV 5G 4mm² P5/P12 BLACK - 7021528002447 - 800245 BFOU 0.6/1kV 2X 4/6mm² P5/P12 BLACK Yes 7021528002454 1043622 800246 BFOU 0.6/1kV 3X 4/6mm² P5/P12 BLACK Yes 7021528002461 1043642 800247 BFOU 0.6/1kV 4X 4/6mm² P5/P12 BLACK - 7021528002478 1043662 800250 BFOU 0.6/1kV 3G 4mm² P5/P12 BLACK - 7021528002508 - 800251 BFOU 0.6/1kV 2X 6/6mm² P5/P12 BLACK Yes 7021528002515 1043623 800252 BFOU 0.6/1kV 3X 6/6mm² P5/P12 BLACK Yes 7021528002522 1043643 800253 BFOU 0.6/1kV 4X 6/6mm² P5/P12 BLACK Yes 7021528002539 1043663 800254 BFOU 0.6/1kV 3G 6mm² P5/P12 BLACK - 7021528002546 - 800255 BFOU 0.6/1kV 4G 6mm² P5/P12 BLACK - 7021528002553 - 800256 BFOU 0.6/1kV 5G 6mm² P5/P12 BLACK - 7021528002560 - 800257 BFOU 0.6/1kV 2X 10/10 P5/P12 BLACK - 7021528002577 1043624 800258 BFOU 0.6/1kV 3X 10/10 P5/P12 BLACK Yes 7021528002584 1043644 800259 BFOU 0.6/1kV 4X 10/10 P5/P12 BLACK - 7021528002591 1043664 800260 BFOU 0.6/1kV 3G 10mm² P5/P12 BLACK - 7021528002607 - 800261 BFOU 0.6/1kV 4G 10mm² P5/P12 BLACK - 7021528002614 - 800262 BFOU 0.6/1kV 5G 10mm² P5/P12 BLACK - 7021528002621 - 800263 BFOU 0.6/1kV 2X 16/16 P5/P12 BLACK - 7021528002638 1043625 800264 BFOU 0.6/1kV 3X 16/16 P5/P12 BLACK Yes 7021528002645 1043645 800265 BFOU 0.6/1kV 4X 16/16 P5/P12 BLACK Yes 7021528002652 1043665 800266 BFOU 0.6/1kV 3G 16mm² P5/P12 BLACK - 7021528002669 - 800267 BFOU 0.6/1kV 5G 16mm² P5/P12 BLACK - 7021528002676 - 800268 BFOU 0.6/1kV 4G 16mm² P5/P12 BLACK - 7021528002683 - 800269 BFOU 0.6/1kV 2X 25/16 P5/P12 BLACK - 7021528002690 1043626 800270 BFOU 0.6/1kV 3X 25/16 P5/P12 BLACK Yes 7021528002706 1043646 800271 BFOU 0.6/1kV 4X 25/16 P5/P12 BLACK Yes 7021528002713 1043666 800272 BFOU 0.6/1kV 4G 25mm² P5/P12 BLACK - 7021528002720 - 800273 BFOU 0.6/1kV 5G 25mm² P5/P12 BLACK - 7021528002737 - 800275 BFOU 0.6/1kV 2X 35/16 P5/P12 BLACK - 7021528002751 1043627 800276 BFOU 0.6/1kV 3X 35/16 P5/P12 BLACK Yes 7021528002768 1043647 800277 BFOU 0.6/1kV 4X 35/16 P5/P12 BLACK - 7021528002775 1043667 800278 BFOU 0.6/1kV 3G 35mm² P5/P12 BLACK - 7021528002782 - 800279 BFOU 0.6/1kV 4G 35mm² P5/P12 BLACK - 7021528002799 - 800280 BFOU 0.6/1kV 5G 35mm² P5/P12 BLACK - 7021528002805 - 800282 BFOU 0.6/1kV 3X 50/25 P5/P12 BLACK Yes 7021528002829 1043648 800283 BFOU 0.6/1kV 4X 50/25 P5/P12 BLACK Yes 7021528002836 1043668 800284 BFOU 0.6/1kV 5G 50mm² P5/P12 BLACK - 7021528002843 - 800285 BFOU 0.6/1kV 4G 50mm² P5/P12 BLACK - 7021528002850 - 800287 BFOU 0.6/1kV 2X 70/35 P5/P12 BLACK - 7021528002874 1043629 800288 BFOU 0.6/1kV 3X 70/35 P5/P12 BLACK Yes 7021528002881 1043649 800289 BFOU 0.6/1kV 4X 70/35 P5/P12 BLACK - 7021528002898 1043669 800290 BFOU 0.6/1kV 4G 70mm² P5/P12 BLACK - 7021528002904 - 800291 BFOU 0.6/1kV 5G 70mm² P5/P12 BLACK - 7021528002911 - 800295 BFOU 0.6/1kV 3X 95/50 P5/P12 BLACK Yes 7021528002959 1043650 800296 BFOU 0.6/1kV 4X 95/50 P5/P12 BLACK Yes 7021528002966 1043670 800297 BFOU 0.6/1kV 4G 95mm² P5/P12 BLACK - 7021528002973 - 800298 BFOU 0.6/1kV 5G 95mm² P5/P12 BLACK - 7021528002980 - 800301 BFOU 0.6/1kV 3X 120/60 P5/P12 BLACK Yes 7021528003017 1043651 800304 BFOU 0.6/1kV 4X 120/60 P5/P12 BLACK - 7021528003048 - 800306 BFOU 0.6/1kV 4G 120mm² P5/P12 BLACK - 7021528003062 -

212

Page 220: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU 1kV(4).doc 03/06/2008 09:00:00

Page 6 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable

www.drakaMOG.com Subject to change without prior notice

Part number Description Sheath Colour Stock item EAN No. DNK EL No. 800307 BFOU 0.6/1kV 4G 150mm² P5/P12 BLACK - 7021528003079 - 800310 BFOU 0.6/1kV 4G 185mm² P5/P12 BLACK - 7021528003109 -

Electrical values power cables Number

of elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type 2

Max. conductor

resistance at 20°C,

Ohm/km

Max. conductor

resistance at 90°C,

Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Current rating IEC 60092-352 Table B.4, Ampere

Short circuit

rating 1 second, Ampere

1 16 4 STCC 1.16 1.48 0.118 0.142 96 2240 1 25 6 STCC 0.734 0.936 0.114 0.136 127 3500 1 50 10 STCC 0.391 0.499 0.105 0.126 196 7000 1 70 10 STCC 0.27 0.344 0.1 0.12 242 9800 1 95 10 STCC 0.195 0.249 0.097 0.116 293 13300 1 120 10 STCC 0.154 0.196 0.095 0.114 339 16800 1 150 10 STCC 0.126 0.161 0.094 0.112 389 21000 1 185 10 STCC 0.1 0.128 0.092 0.11 444 25900 1 240 16 STCC 0.0762 0.0972 0.09 0.108 522 33600 1 300 16 STCC 0.0607 0.0774 0.088 0.106 601 42000 2 1.5 4 STCC 12.2 15.6 0.115 0.138 20 210 3G 1.5 - STCC 12.2 15.6 0.115 0.138 20 210 4G 1.5 - STCC 12.2 15.6 0.115 0.138 16 210 3 1.5 6 STCC 12.2 15.6 0.115 0.138 16 210 4 1.5 6 STCC 12.2 15.6 0.115 0.138 16 210 5 1.5 6 STCC 12.2 15.6 0.115 0.138 13.5 210 7 1.5 6 STCC 12.2 15.6 0.115 0.138 12 210 12 1.5 10 STCC 12.2 15.6 0.115 0.138 10 210 19 1.5 10 STCC 12.2 15.6 0.115 0.138 8.5 210 27 1.5 16 STCC 12.2 15.6 0.115 0.138 7.5 210 37 1.5 16 STCC 12.2 15.6 0.115 0.138 7 210 5G 1.5 - STCC 12.2 15.6 0.115 0.138 16 210 32 1.5 16 STCC 12.2 15.6 0.115 0.138 7 210 7G 2.5 - STCC 7.56 9.64 0.107 0.129 16.5 350 2 2.5 6 STCC 7.56 9.64 0.107 0.129 26 350 3G 2.5 - STCC 7.56 9.64 0.107 0.129 26 350 3 2.5 6 STCC 7.56 9.64 0.107 0.129 21 350 4G 2.5 - STCC 7.56 9.64 0.107 0.129 21 350 4 2.5 6 STCC 7.56 9.64 0.107 0.129 21 350 8G 2.5 - STCC 7.56 9.64 0.107 0.129 15.5 350 7 2.5 6 STCC 7.56 9.64 0.107 0.129 15.5 350 12 2.5 10 STCC 7.56 9.64 0.107 0.129 13 350 19 2.5 10 STCC 7.56 9.64 0.107 0.129 11 350 27 2.5 16 STCC 7.56 9.64 0.107 0.129 10 350 37 2.5 25 STCC 7.56 9.64 0.107 0.129 9 350 5G 2.5 - STCC 7.56 9.64 0.107 0.129 21 350 4G 4 - STCC 4.7 5.99 0.1 0.120 28 560 5G 4 - STCC 4.7 5.99 0.1 0.120 28 560 2 4 6 STCC 4.7 5.99 0.100 0.120 34 560 3 4 6 STCC 4.7 5.99 0.100 0.120 28 560 4 4 6 STCC 4.7 5.99 0.1 0.120 28 560 3G 4 - STCC 4.7 5.99 0.1 0.120 34 560 2 6 6 STCC 3.11 3.97 0.094 0.112 44 840 3 6 6 STCC 3.11 3.97 0.094 0.112 36 840 4 6 6 STCC 3.11 3.97 0.094 0.112 36 840 3G 6 - STCC 3.11 3.97 0.094 0.112 44 840 4G 6 - STCC 3.11 3.97 0.094 0.112 36 840 5G 6 - STCC 3.11 3.97 0.094 0.112 36 840 2 10 10 STCC 1.84 2.35 0.088 0.105 61 1400 3 10 10 STCC 1.84 2.35 0.088 0.105 50 1400 4 10 10 STCC 1.84 2.35 0.088 0.105 50 1400

213

Page 221: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU 1kV(4).doc 03/06/2008 09:00:00

Page 7 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable

www.drakaMOG.com Subject to change without prior notice

Number of

elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type 2

Max. conductor

resistance at 20°C,

Ohm/km

Max. conductor

resistance at 90°C,

Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Current rating IEC 60092-352 Table B.4, Ampere

Short circuit

rating 1 second, Ampere

3G 10 - STCC 1.84 2.35 0.088 0.105 61 1400 4G 10 - STCC 1.84 2.35 0.088 0.105 50 1400 5G 10 - STCC 1.84 2.35 0.088 0.105 50 1400 2 16 16 STCC 1.16 1.48 0.082 0.099 80 2240 3 16 16 STCC 1.16 1.48 0.082 0.099 67 2240 4 16 16 STCC 1.16 1.48 0.082 0.099 67 2240 3G 16 - STCC 1.16 1.48 0.082 0.099 80 2240 5G 16 - STCC 1.16 1.48 0.082 0.099 67 2240 4G 16 - STCC 1.16 1.48 0.082 0.099 67 2240 2 25 16 STCC 0.734 0.936 0.081 0.098 108 3500 3 25 16 STCC 0.734 0.936 0.081 0.098 89 3500 4 25 16 STCC 0.734 0.936 0.081 0.098 89 3500 4G 25 - STCC 0.734 0.936 0.081 0.098 89 3500 5G 25 - STCC 0.734 0.936 0.081 0.098 89 3500 2 35 16 STCC 0.529 0.675 0.078 0.094 133 4900 3 35 16 STCC 0.529 0.675 0.078 0.094 110 4900 4 35 16 STCC 0.529 0.675 0.078 0.094 110 4900 3G 35 - STCC 0.529 0.675 0.078 0.094 133 4900 4G 35 - STCC 0.529 0.675 0.078 0.094 110 4900 5G 35 - STCC 0.529 0.675 0.078 0.094 110 4900 3 50 25 STCC 0.391 0.499 0.078 0.093 137 7000 4 50 25 STCC 0.391 0.499 0.078 0.093 137 7000 5G 50 - STCC 0.391 0.499 0.078 0.093 137 7000 4G 50 - STCC 0.391 0.499 0.078 0.093 137 7000 2 70 35 STCC 0.27 0.344 0.075 0.092 206 9800 3 70 35 STCC 0.27 0.344 0.077 0.092 169 9800 4 70 35 STCC 0.27 0.344 0.077 0.092 169 9800 4G 70 - STCC 0.27 0.344 0.075 0.092 169 9800 5G 70 - STCC 0.27 0.344 0.075 0.092 169 9800 3 95 50 STCC 0.195 0.249 0.075 0.090 205 13300 4 95 50 STCC 0.195 0.249 0.075 0.090 205 13300 4G 95 - STCC 0.195 0.249 0.075 0.090 205 13300 5G 95 - STCC 0.195 0.249 0.075 0.090 205 13300 3 120 60 STCC 0.154 0.196 0.073 0.088 237 16800 4 120 60 STCC 0.154 0.196 0.073 0.088 237 16800 4G 120 - STCC 0.154 0.196 0.073 0.088 237 16800 4G 150 - STCC 0.126 0.161 0.073 0.088 272 21000 4G 185 - STCC 0.1 0.128 0.073 0.088 311 25900

Ambient temperature correction factors Ambient Temp °C 35 40 45 50 55 60 65 70 75 80

Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations Minimum Bending Radius

during Installation Minimum Bending Radius Fixed

Installed Maximum Tensile Load

During Installation Minimum Installation

Temperature

8 x D 6 x D 50 N /mm² -20°C

214

Page 222: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU 1kV(4).doc 03/06/2008 09:00:00

Page 8 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable

www.drakaMOG.com Subject to change without prior notice

Fire resistant, flame retardant halogen-free power cable. Mud resistant. Single core cable.

BFOU 0,6/1kV MGT/EPR/EPR/TCWB/EVA NEK 606 CodeP5/P12 Operating temperature : 90°C Operating Voltage : 0,6/1kV

Application Fixed installation for power, control and lighting in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK 606.

Standards applied

IEC 60092-353/60502-1 - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60331-21 - Fire Resistant IEC 60754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner covering

PET tape

Armour/screen O Tinned annealed copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "år" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX - FLAME IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229

Manufacturing unit DRAKA 01 = Draka Norsk Kabel Outer sheath colour Black

215

Page 223: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU 1kV(4).doc 03/06/2008 09:00:00

Page 9 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable

www.drakaMOG.com Subject to change without prior notice

Core identification power cables Single core – Black Two cores - Blue – Brown Three cores - Brown - Black – Grey Four cores - Blue - Brown - Black – Grey Five cores - Blue - Brown - Black - Grey – Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue – Brown Three cores + earth (4G) - Yellow/green - Brown - Black – Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black – Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 400 25 26.00 2.4 1.4 35 ± 1.5 0.4 2.1 41 ± 2 5100 3940 1 630 25 32.80 2.8 1.4 42 ± 2 0.4 2.3 48.5 ± 2 7660 6167

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

800211 BFOU 0.6/1kV 1X 400/25 P5/P12 BLACK - 7021528002119 - 800213 BFOU 0.6/1kV 1X 630/25 P5/P12 BLACK - 7021528002133 -

Electrical values power cables Number

of elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type 2

Max. conductor

resistance at 20°C,

Ohm/km

Max. conductor

resistance at 90°C,

Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Current rating IEC 60092-352 Table B.4, Ampere

Short circuit

rating 1 second, Ampere

1 400 25 STCC 0.0475 0.0606 0.088 0.105 690 dc / 670 ac 56000

1 630 25 STCC 0.0286 0.0606 0.084 0.101 890dc / 780 ac 88200

Ambient temperature correction factors Ambient Temp °C 35 40 45 50 55 60 65 70 75 80

Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

216

Page 224: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU 1kV(4).doc 03/06/2008 09:00:00

Page 10 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable

www.drakaMOG.com Subject to change without prior notice

Fire resistant, flame retardant halogen-free power cable. Mud resistant. Double braided.

BFOU 0,6/1kV MGT/EPR/EPR/TCWB/EVA NEK 606 CodeP5/P12 Operating temperature : 90°C Operating Voltage : 0,6/1kV

Application Fixed installation for power, control and lighting in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK 606.

Standards applied

IEC 60092-353 - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60331-21 - Fire Resistant IEC 60754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner covering

PET tape + rubberized Polyamide tape

Armour/screen O Two layers of tinned copper wire braid (double braid) Tape over armour/screen

PET tape + rubberized Polyamide tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "år" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX - FLAME IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229

Manufacturing unit DRAKA 01 = Draka Norsk Kabel Outer sheath colour Black

217

Page 225: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU 1kV(4).doc 03/06/2008 09:00:00

Page 11 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable

www.drakaMOG.com Subject to change without prior notice

Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

3 150 70 15.90 1.8 1.4 46 ± 2 0.4 2.6 54.5 ± 2.5 7390 4870

4 150 70 15.90 1.8 1.6 52 ± 2.5 0.5 2.8 61 ± 3 9380 6352

3 240 120 19.1 2.2 2.0 56.0 ±2.0 0.7 3.0 65.0 ± 3.0 11950 8059

4 185 95 17.7 2.0 1.8 57.5 ± 2.5 0.4 2.9 68±3 11640 7750

3 185 95 17.70 2.0 1.6 51.5 ± 2.5 0.5 2.8 61 ± 3 9370 6291

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

800302 BFOU 0.6/1kV 3X 150/70 P5/P12 BLACK Yes 7021528003024 1043652 800309 BFOU 0.6/1kV 4X 150/70 P5/P12 BLACK - 7021528003093 - 800314 BFOU 0.6/1kV 3X 240/120 P5/P12 BLACK - 7021528003147 - 800391 BFOU 0.6/1kV 4X 185/95 P5/P12 BLACK - 7021528003918 - 800392 BFOU 0.6/1kV 3X 185/95 P5/P12 BLACK - 7021528003925 -

Electrical values power cables Number

of elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type

Max. conductor

resistance at 20°C,

Ohm/km

Max. conductor

resistance at 90°C,

Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Current rating IEC 60092-352 Table B.4, Ampere

Short circuit

rating 1 second, Ampere

3 150 70 KGTFR 0.126 0.161 0.073 0.088 272 21000 4 150 70 KGTFR 0.126 0.161 0.073 0.088 272 21000 3 240 120 KGTFR 0.0762 0.0972 0.074 0.089 365 33600 4 185 95 KGTFR 0.1 0.128 0.073 0.088 311 25900 3 185 95 KGTFR 0.1 0.128 0.073 0.088 311 25900

218

Page 226: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU 1kV(4).doc 03/06/2008 09:00:00

Page 12 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable

www.drakaMOG.com Subject to change without prior notice

Ambient temperature correction factors Ambient Temp °C 35 40 45 50 55 60 65 70 75 80

Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

219

Page 227: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU(C) 250V(3).doc 04/06/2008 10:57:00

Page 1 of 4

FlexFlame BFOU(c) 250V S4/S8 Instr. cable

Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant

BFOU(c) 250V

MGT/EPR/EPR/TCWB/EVA NEK 606 CodeS4/S8 Operating temperature : 90°CO perating Voltage : 250V

Application Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the

ud resistant requirements in NEK 606. m

Standards applied

IEC 60092-376 (2003-05) - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame RetardantIEC 60332-3-22 - Flame RetardantIEC 60331-21, -31 - Fire Resistant IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)

Pair / Triple / Quad twisting

Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.

Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner covering

PET tape

Armour/screen O Tinned annealed copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text Eg. "meter" "year" DRAKA 01 BFOU(c) 250V S4/S8 4 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229

Manufacturing unit

DRAKA 01 = Draka Norsk Kabel

Outer sheath colour

Grey or Blue

www.drakaMOG.com Subject to change without prior notice

220

Page 228: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU(C) 250V(3).doc 04/06/2008 10:57:00

Page 2 of 4

FlexFlame BFOU(c) 250V S4/S8 Instr. cable

Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey

Range and dimensions

www.drakaMOG.com Subject to change without prior notice

Number of elements

No of cores in element

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

2 2 0.75 1.1 0.6 1.1 10.5 ± 0.8 0.3 1.3 14.5 ±

0.8 340 114

2 2 0.75 1.1 0.6 1.1 10.5 ± 0.8 0.3 1.3 14.5 ±

0.8 340 114

4 2 0.75 1.1 0.6 1.1 12.5 ± 0.8 0.3 1.4 16 ± 0.8 450 156

4 2 0.75 1.1 0.6 1.1 12.5 ± 0.8 0.3 1.4 16 ± 0.8 450 156

8 2 0.75 1.1 0.6 1.1 16.5 ± 0.8 0.3 1.5 20.5 ± 1 680 240

8 2 0.75 1.1 0.6 1.1 16.5 ± 0.8 0.3 1.5 20.5 ± 1 680 240

12 2 0.75 1.1 0.6 1.3 19.5 ± 0.8 0.3 1.6 23.5 ± 1 920 333

12 2 0.75 1.1 0.6 1.3 19.5 ± 0.8 0.3 1.6 23.5 ± 1 920 333

16 2 0.75 1.1 0.6 1.4 21 ± 1 0.3 1.7 25.5 ± 1 1090 384 16 2 0.75 1.1 0.6 1.4 21 ± 1 0.3 1.7 25.5 ± 1 1090 384 19 2 0.75 1.1 0.6 1.4 22 ± 1 0.3 1.8 27 ± 1 1240 447

24 2 0.75 1.1 0.6 1.8 26.5 ± 1 0.3 2 31.5 ± 1.5 1590 536

24 2 0.75 1.1 0.6 1.8 26.5 ± 1 0.3 2 31.5 ± 1.5 1590 536

2 3 0.75 1.1 0.6 1.1 12 ± 0.8 0.3 1.3 15.5 ± 0.8 400 143

2 3 0.75 1.1 0.6 1.1 12 ± 0.8 0.3 1.3 15.5 ± 0.8 400 143

4 3 0.75 1.1 0.6 1.1 14 ± 0.8 0.3 1.4 18 ± 0.8 550 198 4 3 0.75 1.1 0.6 1.1 14 ± 0.8 0.3 1.4 18 ± 0.8 550 198

8 3 0.75 1.1 0.6 1.1 18.5 ± 0.8 0.3 1.6 23 ± 1 870 309

8 3 0.75 1.1 0.6 1.1 18.5 ± 0.8 0.3 1.6 23 ± 1 870 309

12 3 0.75 1.1 0.6 1.3 22 ± 1 0.3 1.8 26.5 ± 1 1160 411 12 3 0.75 1.1 0.6 1.3 22 ± 1 0.3 1.8 26.5 ± 1 1160 411 16 3 0.75 1.1 0.6 1.4 24 ± 1 0.3 1.9 29 ± 1 1440 513 16 3 0.75 1.1 0.6 1.4 24 ± 1 0.3 1.9 29 ± 1 1440 513

24 3 0.75 1.1 0.6 1.8 30 ± 1.5 0.4 2.1 35.5 ± 1.5 2180 823

2 2 1.5 1.6 0.7 1.1 13 ± 0.8 0.3 1.4 16.5 ± 0.8 440 162

2 2 1.5 1.6 0.7 1.1 13 ± 0.8 0.3 1.4 16.5 ± 0.8 440 162

4 2 1.5 1.6 0.7 1.1 15 ± 0.8 0.3 1.4 19 ± 0.8 590 235 4 2 1.5 1.6 0.7 1.1 15 ± 0.8 0.3 1.4 19 ± 0.8 590 235 8 2 1.5 1.6 0.7 1.1 20 ± 1 0.3 1.7 24.5 ± 1 980 404 8 2 1.5 1.6 0.7 1.1 20 ± 1 0.3 1.7 24.5 ± 1 980 404 12 2 1.5 1.6 0.7 1.3 23.5 ± 1 0.3 1.8 28.5 ± 1 1300 541 12 2 1.5 1.6 0.7 1.3 23.5 ± 1 0.3 1.8 28.5 ± 1 1300 541 16 2 1.5 1.6 0.7 1.4 26 ± 1 0.3 1.9 30.5 ± 1600 678

221

Page 229: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU(C) 250V(3).doc 04/06/2008 10:57:00

Page 3 of 4

FlexFlame BFOU(c) 250V S4/S8 Instr. cable

www.drakaMOG.com Subject to change without prior notice

Number of elements

No of cores in element

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight Copper of Cable content Approx. Approx. (Kg/Km) (kg/km)

1.5

16 2 1.5 1.6 0.7 1.4 26 ± 1 0.3 1.9 30.5 ± 1.5 1600 678

24 2 1.5 1.6 0.7 1.8 32 ± 1.5 0.4 2.2 38.5 ± 1.5 2430 1031

24 2 1.5 1.6 0.7 1.8 32 ± 1.5 0.4 2.2 38.5 ± 1.5 2430 1031

2 3 1.5 1.6 0.7 1.1 14.5 ± 0.8 0.3 1.4 18.5 ±

0.8 530 208

2 3 1.5 1.6 0.7 1.1 14.5 ± 0.8 0.3 1.4 18.5 ±

0.8 530 208

4 3 1.5 1.6 0.7 1.1 17 ± 0.8 0.3 1.5 21 ± 1 740 308 4 3 1.5 1.6 0.7 1.1 17 ± 0.8 0.3 1.5 21 ± 1 740 308 8 3 1.5 1.6 0.7 1.1 22.5 ± 1 0.3 1.8 27 ± 1 1240 518 8 3 1.5 1.6 0.7 1.1 22.5 ± 1 0.3 1.8 27 ± 1 1240 518 12 3 1.5 1.6 0.7 1.3 27 ± 1 0.3 1.9 32 ± 1.5 1690 736

16 3 1.5 1.6 0.7 1.6 30 ± 1.5 0.4 2.1 35.5 ± 1.5 2300 1035

16 3 1.5 1.6 0.7 1.6 30 ± 1.5 0.4 2.1 35.5 ± 1.5 2300 1035

24 3 1.5 1.6 0.7 2 37 ± 1.5 0.4 2.4 43.5 ± 2 3280 1418 2 2 2.5 2 0.7 1.1 14 ± 0.8 0.3 1.4 18 ± 0.8 520 217

4 2 2.5 2 0.7 1.1 16.5 ± 0.8 0.3 1.5 20.5 ± 1 730 325

8 2 2.5 2 0.7 1.1 22 ± 1 0.3 1.8 27 ± 1 1210 551 16 2 2.5 2 0.7 1.6 29 ± 1 0.4 2.1 35 ± 1.5 2200 1053 24 2 2.5 2 0.7 2 36 ± 1.5 0.4 2.4 42.5 ± 2 3220 1509 8 3 2.5 2 0.7 1.1 25 ± 1 0.3 1.9 30 ± 1.5 1600 762

16 3 2.5 2 0.7 1.6 33 ± 1.5 0.4 2.3 39.5 ± 1.5 2940 1471

Electrical values instrumentation cables Type Capacitance, approx.

(nF/km) Inductance, approx,

(mH/km) Resistance at 20°C, max.

(Ohm/km) L/R ratio,

(microH/Ohm) Unshielded pair 0,75 mm² 100 0,67 26,3 12,7 Unshielded triple 0,75 mm² 100 0,67 26,3 12,7 Unshielded pair 1,5 mm² 110 0,63 12,2 26,6 Unshielded triple 1,5 mm² 110 0,63 12,2 26,6 Unshielded pair 2,5 mm² 125 0,59 7,56 39,0 Unshielded triple 2,5 mm² 125 0,59 7,56 39,0

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

893806 BFOU(C) 2PAIR 0.75mm² S4/S8 GREY Yes 7021528938067 1043821 893807 BFOU(C) 2PAIR 0.75mm² S4/S8 BLUE Yes 7021528938074 1043822 893818 BFOU(C) 4PAIR 0.75mm² S4/S8 GREY Yes 7021528938180 1043823 893819 BFOU(C) 4PAIR 0.75mm² S4/S8 BLUE Yes 7021528938197 1043824 893830 BFOU(C) 8PAIR 0.75mm² S4/S8 GREY Yes 7021528938302 1043828 893831 BFOU(C) 8PAIR 0.75mm² S4/S8 BLUE Yes 7021528938319 1043829 893836 BFOU(C) 12PAIR 0.75mm² S4/S8 GREY Yes 7021528938364 1043830 893837 BFOU(C) 12PAIR 0.75mm² S4/S8 BLUE - 7021528938371 1043831 893842 BFOU(C) 16PAIR 0.75mm² S4/S8 GREY Yes 7021528938425 1043833 893843 BFOU(C) 16PAIR 0.75mm² S4/S8 BLUE Yes 7021528938432 1043834

222

Page 230: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU(C) 250V(3).doc 04/06/2008 10:57:00

Page 4 of 4

FlexFlame BFOU(c) 250V S4/S8 Instr. cable

www.drakaMOG.com Subject to change without prior notice

Part number Description Sheath Colour Stock item EAN No. DNK EL No. 893845 BFOU(C) 19PAIR 0.75mm² S4/S8 GREY - 7021528938456 - 893848 BFOU(C) 24PAIR 0.75mm² S4/S8 GREY Yes 7021528938487 1043836 893849 BFOU(C) 24PAIR 0.75mm² S4/S8 BLUE Yes 7021528938494 1043837 893866 BFOU(C) 2TRIP 0.75mm² S4/S8 GREY Yes 7021528938661 1043921 893867 BFOU(C) 2TRIP 0.75mm² S4/S8 BLUE Yes 7021528938678 1043922 893878 BFOU(C) 4TRIP 0.75mm² S4/S8 GREY Yes 7021528938784 1043924 893879 BFOU(C) 4TRIP 0.75mm² S4/S8 BLUE - 7021528938791 1043925 893890 BFOU(C) 8TRIP 0.75mm² S4/S8 GREY - 7021528938906 1043928 893891 BFOU(C) 8TRIP 0.75mm² S4/S8 BLUE - 7021528938913 1043929 893896 BFOU(C) 12TRIP 0.75mm² S4/S8 GREY - 7021528938968 1043930 893897 BFOU(C) 12TRIP 0.75mm² S4/S8 BLUE - 7021528938975 1043931 893902 BFOU(C) 16TRIP 0.75mm² S4/S8 GREY Yes 7021528939026 1043933 893903 BFOU(C) 16TRIP 0.75mm² S4/S8 BLUE - 7021528939033 1043934 893908 BFOU(C) 24TRIP 0.75mm² S4/S8 GREY - 7021528939088 1043936 894006 BFOU(C) 2PAIR 1.5mm² S4/S8 GREY Yes 7021528940060 1043862 894007 BFOU(C) 2PAIR 1.5mm² S4/S8 BLUE - 7021528940077 1043861 894018 BFOU(C) 4PAIR 1.5mm² S4/S8 GREY Yes 7021528940183 1043863 894019 BFOU(C) 4PAIR 1.5mm² S4/S8 BLUE - 7021528940190 1043864 894030 BFOU(C) 8PAIR 1.5mm² S4/S8 GREY Yes 7021528940305 1043868 894031 BFOU(C) 8PAIR 1.5mm² S4/S8 BLUE - 7021528940312 1043869 894036 BFOU(C) 12PAIR 1.5mm² S4/S8 GREY Yes 7021528940367 1043870 894037 BFOU(C) 12PAIR 1.5mm² S4/S8 BLUE - 7021528940374 1043871 894042 BFOU(C) 16PAIR 1.5mm² S4/S8 GREY Yes 7021528940428 1043873 894043 BFOU(C) 16PAIR 1.5mm² S4/S8 BLUE - 7021528940435 1043874 894048 BFOU(C) 24PAIR 1.5mm² S4/S8 GREY Yes 7021528940480 1043876 894049 BFOU(C) 24PAIR 1.5mm² S4/S8 BLUE - 7021528940497 1043877 894066 BFOU(C) 2TRIP 1.5mm² S4/S8 GREY Yes 7021528940664 1043971 894067 BFOU(C) 2TRIP 1.5mm² S4/S8 BLUE Yes 7021528940671 1043972 894078 BFOU(C) 4TRIP 1.5mm² S4/S8 GREY - 7021528940787 1043973 894079 BFOU(C) 4TRIP 1.5mm² S4/S8 BLUE - 7021528940794 1043974 894090 BFOU(C) 8TRIP 1.5mm² S4/S8 GREY Yes 7021528940909 1043977 894091 BFOU(C) 8TRIP 1.5mm² S4/S8 BLUE - 7021528940916 1043978 894096 BFOU(C) 12TRIP 1.5mm² S4/S8 GREY - 7021528940961 1043979 894102 BFOU(C) 16TRIP 1.5mm² S4/S8 GREY - 7021528941029 1043981 894103 BFOU(C) 16TRIP 1.5mm² S4/S8 BLUE - 7021528941036 1043982 894108 BFOU(C) 24TRIP 1.5mm² S4/S8 GREY - 7021528941081 1043987 894206 BFOU(C) 2PAIR 2.5mm² S4/S8 GREY - 7021528942064 - 894218 BFOU(C) 4PAIR 2.5mm² S4/S8 GREY - 7021528942187 - 894230 BFOU(C) 8PAIR 2.5mm² S4/S8 GREY - 7021528942309 - 894242 BFOU(C) 16PAIR 2.5mm² S4/S8 GREY - 7021528942422 - 894248 BFOU(C) 24PAIR 2.5mm² S4/S8 GREY - 7021528942484 - 894290 BFOU(C) 8TRIP 2.5mm² S4/S8 GREY - 7021528942903 - 894302 BFOU(C) 16TRIP 2.5mm² S4/S8 GREY - 7021528943023 -

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

223

Page 231: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU(I) 250V(3).doc 04/06/2008 10:39:00

Page 1 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable

Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant

BFOU(i) 250VMGT/EPR/EPR/TCWB/EVA NEK 606 CodeS3/S7 Operating temperature : 90°CO perating Voltage : 250V

Application Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance

xists. Meets the mud resistant requirements in NEK 606. e

Standards applied

IEC 60092-376 (2003-05) - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60331-21, -31 - Fire Resistant IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)

Pair / Triple / Quad twisting

Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.

Lay up / Shielding

Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape.

Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over inner covering

PET tape

Armour/screen O Tinned annealed copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text Eg. "meter" "year" DRAKA 01 BFOU(i) 250V S3/S7 16 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229

Manufacturing unit

DRAKA 01 = Draka Norsk Kabel

Outer sheath colour

Grey or Blue

www.drakaMOG.com Subject to change without prior notice

224

Page 232: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU(I) 250V(3).doc 04/06/2008 10:39:00

Page 2 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable

Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey

Range and dimensions

Number of elements

No of cores in element

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 2 0.75 1.1 0.6 1.1 7.5 ± 0.5 0.2 1.1 10.5 ± 0.8 200 55

1 2 0.75 1.1 0.6 1.1 7.5 ± 0.5 0.2 1.1 10.5 ± 0.8 200 55

2 2 0.75 1.1 0.6 1.1 11 ± 0.8 0.3 1.3 14.5 ± 0.8 360 135

2 2 0.75 1.1 0.6 1.1 11 ± 0.8 0.3 1.3 14.5 ± 0.8 360 135

4 2 0.75 1.1 0.6 1.1 12.5 ± 0.8 0.3 1.4 16.5 ±

0.8 490 186

4 2 0.75 1.1 0.6 1.1 12.5 ± 0.8 0.3 1.4 16.5 ±

0.8 490 186

8 2 0.75 1.1 0.6 1.1 17 ± 0.8 0.3 1.6 21.5 ± 1 780 288 8 2 0.75 1.1 0.6 1.1 17 ± 0.8 0.3 1.6 21.5 ± 1 780 288 12 2 0.75 1.1 0.6 1.3 20.5 ± 1 0.3 1.7 25 ± 1 1050 381 12 2 0.75 1.1 0.6 1.3 20.5 ± 1 0.3 1.7 25 ± 1 1050 381 16 2 0.75 1.1 0.6 1.4 23 ± 1 0.3 1.8 27.5 ± 1 1310 475 16 2 0.75 1.1 0.6 1.4 23 ± 1 0.3 1.8 27.5 ± 1 1310 475 19 2 0.75 1.1 0.6 1.4 24 ± 1 0.3 1.9 28.5 ± 1 1460 526 19 2 0.75 1.1 0.6 1.4 24 ± 1 0.3 1.9 28.5 ± 1 1460 526

24 2 0.75 1.1 0.6 1.8 29 ± 1 0.4 2.1 34.5 ± 1.5 2000 723

24 2 0.75 1.1 0.6 1.8 29 ± 1 0.4 2.1 34.5 ± 1.5 2000 723

1 3 0.75 1.1 0.6 1.1 8 ± 0.5 0.2 1.1 11 ± 0.8 220 68 1 3 0.75 1.1 0.6 1.1 8 ± 0.5 0.2 1.1 11 ± 0.8 220 68

2 3 0.75 1.1 0.6 1.1 12 ± 0.8 0.3 1.4 15.5 ± 0.8 410 147

2 3 0.75 1.1 0.6 1.1 12 ± 0.8 0.3 1.4 15.5 ± 0.8 410 147

4 3 0.75 1.1 0.6 1.1 14 ± 0.8 0.3 1.4 17.5 ± 0.8 570 212

4 3 0.75 1.1 0.6 1.1 14 ± 0.8 0.3 1.4 17.5 ± 0.8 570 212

8 3 0.75 1.1 0.6 1.1 18.5 ± 0.8 0.3 1.7 23 ± 1 970 364

8 3 0.75 1.1 0.6 1.1 18.5 ± 0.8 0.3 1.7 23 ± 1 970 364

12 3 0.75 1.1 0.6 1.3 22.5 ± 1 0.3 1.8 27 ± 1 1300 484 12 3 0.75 1.1 0.6 1.3 22.5 ± 1 0.3 1.8 27 ± 1 1300 484 16 3 0.75 1.1 0.6 1.4 25.5 ± 1 0.3 1.9 30 ± 1.5 1630 604

19 3 0.75 1.1 0.6 1.6 26.5 ± 1 0.3 2 31.5 ± 1.5 1850 675

24 3 0.75 1.1 0.6 1.8 31.5 ± 1.5 0.4 2.2 37.5 ±

1.5 2460 924

24 3 0.75 1.1 0.6 1.8 31.5 ± 1.5 0.4 2.2 37.5 ±

1.5 2460 924

1 2 1.5 1.6 0.7 1.1 9 ± 0.5 0.2 1.1 12 ± 0.8 255 79 1 2 1.5 1.6 0.7 1.1 9 ± 0.5 0.2 1.1 12 ± 0.8 255 79 2 2 1.5 1.6 0.7 1.1 13 ± 0.8 0.3 1.4 17 ± 0.8 470 186 2 2 1.5 1.6 0.7 1.1 13 ± 0.8 0.3 1.4 17 ± 0.8 470 186

www.drakaMOG.com Subject to change without prior notice

225

Page 233: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU(I) 250V(3).doc 04/06/2008 10:39:00

Page 3 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable

www.drakaMOG.com Subject to change without prior notice

Number of elements

No of cores in element

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

4 2 1.5 1.6 0.7 1.1 15.5 ± 0.8 0.3 1.5 19.5 ±

0.8 660 271

4 2 1.5 1.6 0.7 1.1 15.5 ± 0.8 0.3 1.5 19.5 ±

0.8 660 271

8 2 1.5 1.6 0.7 1.1 21 ± 1 0.3 1.7 25.5 ± 1 1080 451 8 2 1.5 1.6 0.7 1.1 21 ± 1 0.3 1.7 25.5 ± 1 1080 451 12 2 1.5 1.6 0.7 1.3 25 ± 1 0.3 1.9 30 ± 1.5 1490 613 12 2 1.5 1.6 0.7 1.3 25 ± 1 0.3 1.9 30 ± 1.5 1490 613 16 2 1.5 1.6 0.7 1.6 29 ± 1 0.3 2 34 ± 1.5 1920 776 16 2 1.5 1.6 0.7 1.6 29 ± 1 0.3 2 34 ± 1.5 1920 776

19 2 1.5 1.6 0.7 1.6 30 ± 1.5 0.4 2.1 35.5 ± 1.5 2290 1009

24 2 1.5 1.6 0.7 1.8 35.5 ± 1.5 0.4 2.3 42 ± 2 2900 1226

24 2 1.5 1.6 0.7 1.8 35.5 ± 1.5 0.4 2.3 42 ± 2 2970 1226

1 3 1.5 1.6 0.7 1.1 9.5 ± 0.5 0.2 1.2 12.5 ± 0.8 285 93

1 3 1.5 1.6 0.7 1.1 9.5 ± 0.5 0.2 1.2 12.5 ± 0.8 285 93

2 3 1.5 1.6 0.7 1.1 14.5 ± 0.8 0.3 1.5 18.5 ±

0.8 550 214

2 3 1.5 1.6 0.7 1.1 14.5 ± 0.8 0.3 1.5 18.5 ±

0.8 560 214

4 3 1.5 1.6 0.7 1.1 17 ± 0.8 0.3 1.6 21 ± 1 810 344 4 3 1.5 1.6 0.7 1.1 17 ± 0.8 0.3 1.6 21 ± 1 810 344 8 3 1.5 1.6 0.7 1.1 22.5 ± 1 0.3 1.8 27 ± 1 1360 589 8 3 1.5 1.6 0.7 1.1 22.5 ± 1 0.3 1.8 27 ± 1 1360 589

12 3 1.5 1.6 0.7 1.5 28.5 ± 1 0.3 2 33.5 ± 1.5 1920 810

12 3 1.5 1.6 0.7 1.5 28.5 ± 1 0.3 2 33.5 ± 1.5 1920 810

16 3 1.5 1.6 0.7 1.6 31.5 ± 1.5 0.4 2.2 37.5 ±

1.5 2600 1180

16 3 1.5 1.6 0.7 1.6 31.5 ± 1.5 0.4 2.2 37.5 ±

1.5 2600 1180

24 3 1.5 1.6 0.7 2 39.5 ± 1.5 0.4 2.5 46.5 ± 2 3720 1611

24 3 1.5 1.6 0.7 2 39.5 ± 1.5 0.4 2.5 46.5 ± 2 3720 1611

1 2 2.5 2 0.7 1.1 9.5 ± 0.5 0.2 1.2 13 ± 0.8 300 99 1 2 2.5 2 0.7 1.1 9.5 ± 0.5 0.2 1.2 13 ± 0.8 300 99

2 2 2.5 2 0.7 1.1 14.5 ± 0.8 0.3 1.5 18.5 ±

0.8 550 225

4 2 2.5 2 0.7 1.1 17 ± 0.8 0.3 1.6 21.5 ± 1 820 367 8 2 2.5 2 0.7 1.1 23.5 ± 1 0.3 1.8 28 ± 1 1370 633 16 2 2.5 2 0.7 1.6 32 ± 1.5 0.4 2.2 38 ± 1.5 2590 1221

1 3 2.5 2 0.7 1.1 10.5 ± 0.8 0.2 1.2 13.5 ±

0.8 350 129

8 3 2.5 2 0.7 1.3 25.5 ± 1 0.3 2 30.5 ± 1.5 1790 844

12 3 2.5 2 0.7 1.5 31.5 ± 1.5 0.4 2.2 37.5 ±

1.5 2610 1284

226

Page 234: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU(I) 250V(3).doc 04/06/2008 10:39:00

Page 4 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable

Electrical values instrumentation cables Type Capacitance, approx.

(nF/km) Inductance, approx,

(mH/km) Resistance at 20°C, max.

(Ohm/km) L/R ratio,

(microH/Ohm) Shielded pair 0,75 mm² 110 0,67 26,3 12,7 Shielded triple 0,75 mm² 110 0,67 26,3 12,7 Shielded pair 1,5 mm² 125 0,63 12,2 26,6 Shielded triple 1,5 mm² 125 0,63 12,2 26,6 Shielded pair 2,5 mm² 145 0,59 7,56 39,0 Shielded triple 2,5 mm² 145 0,59 7,56 39,0

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

893200 BFOU(I) 1PAIR 0.75mm² S3/S7 GREY Yes 7021528932003 1043820 893201 BFOU(I) 1PAIR 0.75mm² S3/S7 BLUE Yes 7021528932010 1043819 893206 BFOU(I) 2PAIR 0.75mm² S3/S7 GREY Yes 7021528932065 1044020 893207 BFOU(I) 2PAIR 0.75mm² S3/S7 BLUE - 7021528932072 1044019 893218 BFOU(I) 4PAIR 0.75mm² S3/S7 GREY Yes 7021528932188 1044021 893219 BFOU(I) 4PAIR 0.75mm² S3/S7 BLUE - 7021528932195 1044022 893230 BFOU(I) 8PAIR 0.75mm² S3/S7 GREY Yes 7021528932300 1044028 893231 BFOU(I) 8PAIR 0.75mm² S3/S7 BLUE - 7021528932317 1044029 893236 BFOU(I) 12PAIR 0.75mm² S3/S7 GREY - 7021528932362 1044030 893237 BFOU(I) 12PAIR 0.75mm² S3/S7 BLUE - 7021528932379 1044031 893242 BFOU(I) 16PAIR 0.75mm² S3/S7 GREY Yes 7021528932423 1044033 893243 BFOU(I) 16PAIR 0.75mm² S3/S7 BLUE - 7021528932430 1044034 893245 BFOU(I) 19PAIR 0.75mm² S3/S7 GREY Yes 7021528932454 - 893246 BFOU(I) 19PAIR 0.75mm² S3/S7 BLUE Yes 7021528932461 - 893248 BFOU(I) 24PAIR 0.75mm² S3/S7 GREY - 7021528932485 1044036 893249 BFOU(I) 24PAIR 0.75mm² S3/S7 BLUE - 7021528932492 1044037 893260 BFOU(I) 1TRIP 0.75mm² S3/S7 GREY Yes 7021528932607 1043920 893261 BFOU(I) 1TRIP 0.75mm² S3/S7 BLUE Yes 7021528932614 1043919 893266 BFOU(I) 2TRIP 0.75mm² S3/S7 GREY - 7021528932669 1044121 893267 BFOU(I) 2TRIP 0.75mm² S3/S7 BLUE - 7021528932676 1044122 893278 BFOU(I) 4TRIP 0.75mm² S3/S7 GREY - 7021528932782 1044123 893279 BFOU(I) 4TRIP 0.75mm² S3/S7 BLUE - 7021528932799 1044124 893290 BFOU(I) 8TRIP 0.75mm² S3/S7 GREY Yes 7021528932904 1044128 893291 BFOU(I) 8TRIP 0.75mm² S3/S7 BLUE - 7021528932911 1044129 893296 BFOU(I) 12TRIP 0.75mm² S3/S7 GREY - 7021528932966 1044130 893297 BFOU(I) 12TRIP 0.75mm² S3/S7 BLUE - 7021528932973 1044131 893302 BFOU(I) 16TRIP 0.75mm² S3/S7 GREY - 7021528933024 1044132 893305 BFOU(I) 19TRIP 0.75mm² S3/S7 GREY - 7021528933055 - 893308 BFOU(I) 24TRIP 0.75mm² S3/S7 GREY - 7021528933086 1044138 893309 BFOU(I) 24TRIP 0.75mm² S3/S7 BLUE - 7021528933093 1044139 893400 BFOU(I) 1PAIR 1.5mm² S3/S7 GREY Yes 7021528934007 1043860 893401 BFOU(I) 1PAIR 1.5mm² S3/S7 BLUE Yes 7021528934014 1043859 893406 BFOU(I) 2PAIR 1.5mm² S3/S7 GREY Yes 7021528934069 1044060 893407 BFOU(I) 2PAIR 1.5mm² S3/S7 BLUE - 7021528934076 1044061 893418 BFOU(I) 4PAIR 1.5mm² S3/S7 GREY Yes 7021528934182 1044063 893419 BFOU(I) 4PAIR 1.5mm² S3/S7 BLUE - 7021528934199 1044064 893430 BFOU(I) 8PAIR 1.5mm² S3/S7 GREY Yes 7021528934304 1044068 893431 BFOU(I) 8PAIR 1.5mm² S3/S7 BLUE - 7021528934311 1044069 893436 BFOU(I) 12PAIR 1.5mm² S3/S7 GREY Yes 7021528934366 1044070 893437 BFOU(I) 12PAIR 1.5mm² S3/S7 BLUE - 7021528934373 1044071 893442 BFOU(I) 16PAIR 1.5mm² S3/S7 GREY Yes 7021528934427 1044073 893443 BFOU(I) 16PAIR 1.5mm² S3/S7 BLUE - 7021528934434 1044074 893445 BFOU(I) 19PAIR 1.5mm² S3/S7 GREY Yes 7021528934458 - 893448 BFOU(I) 24PAIR 1.5mm² S3/S7 GREY - 7021528934489 1044076 893449 BFOU(I) 24PAIR 1.5mm² S3/S7 BLUE - 7021528934496 - 893460 BFOU(I) 1TRIP 1.5mm² S3/S7 GREY Yes 7021528934601 1044170

www.drakaMOG.com Subject to change without prior notice

227

Page 235: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU(I) 250V(3).doc 04/06/2008 10:39:00

Page 5 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable

www.drakaMOG.com Subject to change without prior notice

Part number Description Sheath Colour Stock item EAN No. DNK EL No. 893461 BFOU(I) 1TRIP 1.5mm² S3/S7 BLUE Yes 7021528934618 1044169 893466 BFOU(I) 2TRIP 1.5mm² S3/S7 GREY - 7021528934663 1044171 893467 BFOU(I) 2TRIP 1.5mm² S3/S7 BLUE - 7021528934670 - 893478 BFOU(I) 4TRIP 1.5mm² S3/S7 GREY - 7021528934786 1044173 893479 BFOU(I) 4TRIP 1.5mm² S3/S7 BLUE - 7021528934793 1044174 893490 BFOU(I) 8TRIP 1.5mm² S3/S7 GREY - 7021528934908 1044177 893491 BFOU(I) 8TRIP 1.5mm² S3/S7 BLUE - 7021528934915 1044178 893496 BFOU(I) 12TRIP 1.5mm² S3/S7 GREY - 7021528934960 1044179 893497 BFOU(I) 12TRIP 1.5mm² S3/S7 BLUE - 7021528934977 1044180 893502 BFOU(I) 16TRIP 1.5mm² S3/S7 GREY - 7021528935028 1044181 893503 BFOU(I) 16TRIP 1.5mm² S3/S7 BLUE - 7021528935035 1044182 893508 BFOU(I) 24TRIP 1.5mm² S3/S7 GREY - 7021528935080 1044193 893509 BFOU(I) 24TRIP 1.5mm² S3/S7 BLUE - 7021528935097 1044194 893600 BFOU(I) 1PAIR 2.5mm² S3/S7 GREY Yes 7021528936001 1044140 893601 BFOU(I) 1PAIR 2.5mm² S3/S7 BLUE - 7021528936018 - 893606 BFOU(I) 2PAIR 2.5mm² S3/S7 GREY - 7021528936063 - 893618 BFOU(I) 4PAIR 2.5mm² S3/S7 GREY - 7021528936186 - 893630 BFOU(I) 8PAIR 2.5mm² S3/S7 GREY - 7021528936308 - 893642 BFOU(I) 16PAIR 2.5mm² S3/S7 GREY - 7021528936421 - 893660 BFOU(I) 1TRIP 2.5mm² S3/S7 GREY - 7021528936605 - 893690 BFOU(I) 8TRIP 2.5mm² S3/S7 GREY - 7021528936902 - 893696 BFOU(I) 12TRIP 2.5mm² S3/S7 GREY - 7021528936964 -

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

228

Page 236: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU-HCF(c)-250V-HF_2006.doc 30.06.2006 08:52

Page 1 of 2

BFOU-HCF(c) 250V S16 / 1100°C / 30 minutes

54

31

2

HydroCarbon Fire resistant, flame retardant halogen-free instrumentation cable.

BFOU-HCF(c) 250VMGT/EPR/EPR/TCWB/EVA/HCF/SHF1

NEK 606 Code S16

1100°C / 2000°F / 200 kW/m²

Operating temperature : 90°CO perating Voltage : 250V

Application

Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for

carbon fire resistance is vital. hydro

Standards applied

IEC 60092-376 (2003-05) - Design Draka Norsk Kabel - HCF protection IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60331-21 - Fire Resistant UL 1709 / ASTM E1529 - HC Fire resistance IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned stranded circular copper, IEC 60228 class 2 Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)

Pair / Triple / Quad twisting

Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.

Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over bedding

PET tape

Armour/screen O Tinned copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

HCF protection -HCF Extruded heatblock compound Tape Lapped glassfibre tape Overall sheath Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-359)

www.drakaMOG.com Subject to change without prior notice

229

Page 237: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU-HCF(c)-250V-HF_2006.doc 30.06.2006 08:52

Page 2 of 2

BFOU-HCF(c) 250V S16 / 1100°C / 30 minutes

www.drakaMOG.com Subject to change without prior notice

Code Letter

Marking text Eg. "meter" "år" DRAKA NORSK KABEL BFOU-HCF(c) 250V S16 4 PAIR 1,5 mm2 HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22

Outer sheath colour

Grey

Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Range and dimensions

Draka Norsk Kabel

part no.

Type

[mm2]

Diameter over bedding

[mm]

Thickness ofarmour wires

[mmØ]

Diameter sheath

[mm]

Diameter overall HCF-

protection

(mm)

Weight of cable approx. [kg/km]

2 pair 1,5 13,0±0,8 0,3 16,5±0,8 44,5±2,0 2400

886562 4 pair 1,5 15,0±0,8 0,3 19,0±0,8 46,5±2,0 2650 8 pair 1,5 20,5±1,0 0,3 25,0±1,0 53,0±2,5 3570 12 pair 1,5 23,5±1,0 0,3 28,5±1,0 57,0±2,5 4160

Electrical values instrumentation cables

TYPE [mm2]

Capacitance approx. [nF/km]

Inductance approx. [mH/km]

Resist. 20°C

[Max.ohm/km] Multi pair 1,5 110 0,63 12,2 Installation recommendations

TYPE

[mm2]

Overall Diameter [mmØ]

Minimum bending radius During Fixed

Installation Installed [mm]

Maximum pulling tension

[N]

20 x D 12 x D

2 pair 1,5 44,5±2,0 890 534 300 4 pair 1,5 46,5±2,0 930 558 600 8 pair 1,5 53,0±2,5 1060 636 1200 12 pair 1,5 57,0±2,5 1140 684 1800

Minimum installation temperature: - 10 °C

230

Page 238: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU-HCF(i)-250V-HF_2006.doc 30.06.2006 08:46

Page 1 of 2

BFOU-HCF(i) 250V S15 / 1100°C / 30 minutes

www.drakaMOG.com Subject to change without prior notice

54

31

2

HydroCarbon Fire resistant, flame retardant halogen-free instrumentation cable.

BFOU-HCF(i) 250VMGT/EPR/EPR/TCWB/EVA/HCF/SHF1

NEK 606 Code S15

1100°C / 2000°F / 200 kW/m²

Operating temperature : 90°CO perating Voltage : 250V

Application

Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for

carbon fire resistance is vital. hydro

Standards applied

IEC 60092-376 (2003-05) - Design Draka Norsk Kabel - HCF protection IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60331-21 - Fire Resistant UL 1709 / ASTM E1529 - HC Fire resistance IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned stranded circular copper, IEC 60228 class 2 Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)

Pair / Triple / Quad twisting

Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.

Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over bedding

PET tape

Armour/screen O Tinned copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

HCF protection -HCF Extruded heatblock compound Tape Lapped glassfibre tape

231

Page 239: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU-HCF(i)-250V-HF_2006.doc 30.06.2006 08:46

Page 2 of 2

BFOU-HCF(i) 250V S15 / 1100°C / 30 minutes

www.drakaMOG.com Subject to change without prior notice

Code Letter

Overall sheath Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-359)

Marking text Eg. "meter" "år" DRAKA NORSK KABEL BFOU-HCF(i) 250V S15 4 PAIR 1,5 mm2 HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22

Outer sheath colour

Grey

Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Range and dimensions

Draka Norsk Kabel

part no.

Type

[mm2]

Diameter over bedding

[mm]

Thickness ofarmour wires

[mmØ]

Diameter sheath

[mm]

Diameter overall HCF-

protection

(mm)

Weight of cable approx. [kg/km]

886563 1 pair 1,5 9,0±0,5 0,2 12,0±0,8 39,5±1,5 1880

2 pair 1,5 13,0±0,8 0,3 17,0±0,8 44,5±2,0 2450 4 pair 1,5 15,5±0,8 0,3 19,5±0,8 47,5±2,0 2830 8 pair 1,5 21.0±1,0 0,3 25,5±1,0 54,5±2,5 3690 12 pair 1,5 25,0±1,0 0,3 30.0±1,5 63,0±3.0 5200

Electrical values instrumentation cables

TYPE [mm2]

Capacitance approx. [nF/km]

Inductance approx. [mH/km]

Resist. 20°C

[Max.ohm/km] single pair 1,5 125 0,63 12,2 Installation recommendations

TYPE

[mm2]

Overall Diameter [mmØ]

Minimum bending radius During Fixed

Installation Installed [mm]

Maximum pulling tension

[N]

20 x D 12 x D

1 pair 1,5 39,5±1,5 790 474 150 2 pair 1,5 44,5±2,0 890 534 300 4 pair 1,5 47,5±2,0 950 570 600 8 pair 1,5 54,5±2,5 1090 654 1200 12 pair 1,5 63,0±3.0 1260 756 1800

Minimum installation temperature: - 10 °C

232

Page 240: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU-HCF-1kv-HF_2006_rev2.doc 30.06.2006 08:54

Page 1 of 5

BFOU-HCF 0,6/1kV P34 / 1100°C / 30-60 minutes

www.drakaMOG.com Subject to change without prior notice

HydroCarbon Fire resistant, flame retardant halogen-free power cable.

BFOU-HCF 0,6/1kVMGT/EPR/EPR/TCWB/EVA/HCF/SHF1

NEK 606 Code P34

1100°C / 2000°F / 200 kW/m²

Operating temperature : 90°CO perating Voltage : 0,6/1kV

Application

Fixed installation for power, control and lightning in both EX- and safe areas, emergency and critical systems

re requirement for fire resistance is vital. whe

Standards applied

IEC 60092-353 - Design Draka Norsk Kabel - HCF protection IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60331-21 - Fire Resistant UL 1709 / ASTM E1529 - HC Fire resistance IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction Code Letter

Conductor Tinned stranded circular copper, IEC 60228 class 2 Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over bedding PET tape Armour/screen O Tinned copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

HCF protection -HCF Extruded heatblock compound Tape Lapped glassfibre tape

Overall sheath Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-359)

Marking text Eg. "meter" "år" DRAKA NORSK KABEL BFOU-HCF 0,6/1kV P34 12 x 2,5/10 mm2 HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22

Outer sheath colour

Black

233

Page 241: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU-HCF-1kv-HF_2006_rev2.doc 30.06.2006 08:54

Page 2 of 5

BFOU-HCF 0,6/1kV P34 / 1100°C / 30-60 minutes

www.drakaMOG.com Subject to change without prior notice

Core identification power cables Single core Grey (Offwhite) Two cores Grey (Offwhite) - Black Three cores Grey (Offwhite) - Black - Red Four cores Grey (Offwhite) - Black - Red - Blue Five cores Grey (Offwhite) - Black - Red - Blue - Black Above five cores Black numbers on white base Separate earth core Yellow/green G / x in cable describtion G = one of the core are yellow/green - x = no yellow/green core Range and dimensions

Draka Norsk Kabel

part no.

Type

[mm2]

Diameter over bedding

[mm]

Thickness ofarmour wires

[mmØ]

Diameter sheath

[mm]

Diameter overall HCF-

protection

(mm)

Weight of cable approx. [kg/km]

1x 50/6 15,0±0,8 0,20 18,5±0,8 45,5±2,5 2900 1x 70/6 16,5±0,8 0,30 20,5±1,0 47,5±2,5 3300 1x 95/10 18,5±0,8 0,30 23,0±1,0 50,5±3,0 3800 1x 120/10 20,5±1,0 0,30 25,0±1,0 52,5±3,0 4260 1x 150/10 23,0±1,0 0,30 27,0±1,0 54,5±3,0 4750 1x 185/10 25,0±1,0 0,30 29,5±1,0 57,5±3,0 5380

886549 1x 240/16 28,0±1,0 0,30 32,5±1,5 66,0±3,5 7050 1x 300/16 30,5±1,5 0,30 35,5±1,5 68,0±3,5 8000

886375 2x 1,5/4 10,0±0,8 0,20 13,0±0,8 40,5±2,5 1890 3x 1,5/4 10,5±0,8 0,20 14,0±0,8 42.0±2,5 2140

886338 3x 2,5/6 11,5±0,8 0,30 15,0±0,8 42,5±2,5 2200 885499 3x 4/6 13,0±0,8 0,30 16,5±0,8 43,0±2,5 2400 885882 3x 6/6 14,0±0,8 0,30 18,0±0,8 45,0±2,5 2600 885138 3x 16/16 18,5±0,8 0,40 23,0±1,0 50,0±3,0 3500

3x 35/16 25,0±1,0 0,30 29,5±1,0 57,5±3,0 4840 3x 70/35 33,0±1,5 0,50 39,0±1,5 72,0±4,0 8150 3x 120/60 41,0±2,0 0,60 48,0±2,0 81,5±4,5 11300 3x 150/70 46,0±2,0 0,40 * 54,5±2,5 88,5±4,5 13300

886547 4x 2,5/6 12.5 ± 0.8 0.30 16.5 ± 0.8 44,0±2,5 2300 4x 6/6 15.5 ± 0.8 0.30 19.5 ± 0.8 47,5±2,5 2870

886546 4x 16/16 20.5 ± 1.0 0.40 25.5 ± 1.0 53,5±3,0 3830 7x 1,5/6 14,0±0,8 0,30 17,5±0,8 44,5±2,5 2550

885139 12x 1,5/10 18,5±0,8 0,30 22,5±1,0 50,0±3,0 3140

234

Page 242: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU-HCF-1kv-HF_2006_rev2.doc 30.06.2006 08:54

Page 3 of 5

BFOU-HCF 0,6/1kV P34 / 1100°C / 30-60 minutes

www.drakaMOG.com Subject to change without prior notice

Draka Norsk Kabel

part no.

Type

[mm2]

Diameter over bedding

[mm]

Thickness ofarmour wires

[mmØ]

Diameter sheath

[mm]

Diameter overall HCF-

protection

(mm)

Weight of cable approx. [kg/km]

885124 7x 2,5/6 15,0±0,8 0,30 19,0±0,8 46,0±2,5 2760 886036 12x 2,5/10 20,5±1,0 0,30 24,5±1,0 52,0±3,0 3500

886548 27x 1,5/16 26.5±1.0 0.30 31.0±1.5 64,5±3,5 5070

* This cable has a double braid (two layers of wires)

ELECTRICAL DATA

No. of cores x cross section

Conductor resistance DC

[Ω/km]

Reactance [Ω/km]

Impedance [Ω/km] at 90

°C

Continous current rating

Short circuit [Ampere]

at 20 °C at 90 °C at 50 / 60 Hz

At 50 / 60 Hz at 45 °C 1 sec 0,3 sec

1 X 50/6 0,391 0,4986 0,161/0,193 0,524/0,535 196 7000 12780 1 X 70/6 0,270 0,344 0,152/0,182 0,376/0,390 242 9800 17892 1 X 95/10 0,195 0,2486 0,146/0,176 0,289/0,305 293 13300 24282 1 X 120/10 0,154 0,1964 0,141/0,170 0,242/0,260 339 16800 30672 1 X 150/10 0,126 0,161 0,137/0,164 0,211/0,223 389 21000 38340 1 X 185/10 0,100 0,128 0,133/0,160 0,185/0,205 444 25900 47286 1 X 240/16 0,0762 0,0972 0,133/0,159 0,165/0,187 522 3360 61344 1 X 300/16 0,0607 0,0774 0,128/0,154 0,150/0,173 601 42000 76681 2x 1,5/4 12,2 15,56 0,115/0,138 15,556/15,567 20 210 383 3x 1,5/4 12,2 15,56 0,115/0,138 15,556/15,567 16 210 383 3x 2,5/6 7,56 9,64 0,107/0,129 9,640/9,641 21 350 639 3x 4/6 4,70 5,99 0,100/0,120 5,993/5,994 28 560 1022 3x 6/6 3,11 3,97 0,094/0,112 3,967/3,9672 36 840 1534 3x 16/16 1,16 1,46 0082/0,099 1,481/1,482 67 2240 4089 3x 35/16 0,529 0,675 0,078/0,094 0,679/0,681 110 4900 8946 3x 70/35 0,270 0,344 0,077/0,092 0,352/0,356 169 9800 17892 3x 120/60 0,154 0,196 0,073/0,088 0,209/0,215 237 16800 30672 3x 150/70 0,126 0,161 0,073/0,088 0,177/0,183 272 21000 38340 4x 2,5/6 7,56 9,64 0,107/0,129 9,640/9,641 21 350 639 4x 6/6 3,11 3,97 0,094/0,112 3,967/3,9672 36 840 1534 4x 16/16 1,16 1,46 0082/0,099 1,481/1,482 67 2240 4089 7x 1,5/6 12,2 15,56 0,115/0,138 15,556/15,567 12 210 383 12x 1,5/10 12,2 15,56 0,115/0,138 15,556/15,567 10 210 383 7x 2,5/6 7,56 9,64 0,107/0,129 9,640/9,641 15,5 350 639

235

Page 243: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU-HCF-1kv-HF_2006_rev2.doc 30.06.2006 08:54

Page 4 of 5

BFOU-HCF 0,6/1kV P34 / 1100°C / 30-60 minutes

www.drakaMOG.com Subject to change without prior notice

No. of cores x cross section

Conductor resistance DC

[Ω/km]

Reactance [Ω/km]

Impedance [Ω/km] at 90

°C

Continous current rating

Short circuit [Ampere]

at 20 °C at 90 °C at 50 / 60 Hz

At 50 / 60 Hz at 45 °C 1 sec 0,3 sec

12x 2,5/10 7,56 9,64 0,107/0,129 9,640/9,641 13 350 639 27x 1,5/16 12,2 15,56 0,115/0,138 15,556/15,567 7,5 210 383 INSTALLATION DATA

TYPE

[mm2]

Overall Diameter [mmØ]

Minimum bending radius During Fixed

Installation Installed [mm]

Maximum pulling tension

[N]

20 x D 12 x D

1x 50/6 45,5±2,5 910 546 2500 1x 70/6 47,5±2,5 950 570 3500

1x 95/10 50,5±3,0 1010 606 4750 1x 120/10 52,5±3,0 1050 630 6000 1x 150/10 54,5±3,0 1090 654 7500 1x 185/10 57,5±3,0 1150 690 9250 1x 240/16 66,0±3,5 1320 792 12000 1x 300/16 68,0±3,5 1360 816 15000

2x 1,5/4 40,5±2,5 810 486 150

3x 1,5/4 42,0±2,5 840 504 225 3x 2,5/6 42,5±2,5 850 510 375 3x 4/6 43,0±2,5 860 516 600 3x 6/6 45,0±2,5 900 540 900

3x 16/16 50,0±3,0 1000 600 2400 3x 35/16 57,5±3,0 1150 690 5250 3x 70/35 72,0±4,0 1440 864 10500 3x 120/60 81,5±4,5 1630 978 18000 3x 150/70 88,5±4,5 1770 1062 20000

4x 2,5/6 44,0±2,5 880 528 500 4x 6/6 47,5±2,5 950 570 1200

4x 16/16 53,5±3,0 1070 642 3200

7x 1,5/6 44,5±2,5 890 536 525 12 x 1,5/10 50,0±3,0 1000 600 900

7x 2,5/6 46,0±2,5 920 552 875

12x 2,5/10 52,0±3,0 1040 624 1500

236

Page 244: Prysmian Draka - Marine & Offshore LV HV Cables

BFOU-HCF-1kv-HF_2006_rev2.doc 30.06.2006 08:54

Page 5 of 5

BFOU-HCF 0,6/1kV P34 / 1100°C / 30-60 minutes

www.drakaMOG.com Subject to change without prior notice

TYPE

[mm2]

Overall Diameter [mmØ]

Minimum bending radius During Fixed

Installation Installed [mm]

Maximum pulling tension

[N]

27x 1,5/16 64,5±3,5 1290 774 2025

Minimum installation temperature: - 10 °C

237

Page 245: Prysmian Draka - Marine & Offshore LV HV Cables

BU 1kV(3).doc 29.12.2006 10:42

Page 1 of 4

BU 0,6/1kV P17, Power cable, Unarmoured

Fire resistant, flame retardant halogen-free power cable. Mud resistant

BU 0,6/1kVMGT/EPR/EVA

NEK 606 CodeP17 Operating temperature : 90°CO perating Voltage : 0,6/1kV

Application

Fixed installation for power, control and lighting in safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Single core cables are double-insulated

attery cables. b

Standards applied

IEC 60092-353 - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60331-21 - Fire Resistant IEC 60754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour.

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "år" DRAKA NORSK KABEL BU 0,6/1kV P17 1 x 70 mm2 IEC 60331-21 IEC 60332-3-22

Outer sheath colour

Black

www.drakaMOG.com Subject to change without prior notice

238

Page 246: Prysmian Draka - Marine & Offshore LV HV Cables

BU 1kV(3).doc 29.12.2006 10:42

Page 2 of 4

BU 0,6/1kV P17, Power cable, Unarmoured

Core identification power cables Single core Grey (Offwhite) Two cores Grey (Offwhite) - Black Three cores Grey (Offwhite) - Black - Red Four cores Grey (Offwhite) - Black - Red - Blue Five cores Grey (Offwhite) - Black - Red - Blue - Black Above five cores Black numbers on white base Separate earth core Yellow/green G / x in cable description G = one of the core are yellow/green - x = no yellow/green core From Q3 2007 the core colours on RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow Cenelec HD 308S2 colours: Single core Black Two cores Blue - Brown Two cores + earth Blue - Brown - Yellow/green Three cores Brown - Black - Grey Three cores + earth Brown - Black - Grey - Yellow/green Four cores Blue - Brown - Black - Grey Four cores + earth Blue - Brown - Black - Grey - Yellow/green Five cores Blue - Brown - Black - Grey - Black Above five cores Black numbers on white base

Range and dimensions

www.drakaMOG.com Subject to change without prior notice

Number of elements

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 16 5.15 1.0 1.1 10 ± 0.8 235 144 1 25 6.45 1.2 1.1 11.5 ± 0.8 350 229 1 35 7.65 1.2 1.2 13 ± 0.8 450 308 1 50 9.0 1.4 1.2 15 ± 0.8 610 430 1 70 10.85 1.4 1.3 17 ± 0.8 840 620 1 95 12.60 1.6 1.4 19.5 ± 0.8 1110 836 1 120 14.20 1.6 1.4 21 ± 1 1380 1075 1 150 15.90 1.8 1.5 23.5 ± 1 1700 1336 1 185 17.70 2.0 1.6 26 ± 1 2100 1663 1 10 4.05 1.0 1 8.5 ± 0.5 160 90 2 1.5 1.6 1.0 1.1 10 ± 0.8 150 28 3G 1.5 1.6 1.0 1.1 10.5 ± 0.8 175 42 3 1.5 1.6 1.0 1.1 10.5 ± 0.8 175 42 7 1.5 1.6 1.0 1.3 14.5 ± 0.8 330 98 19 1.5 1.6 1.0 1.5 22.5 ± 1 760 264 2 2.5 2.0 1.0 1.1 11 ± 0.8 185 46 3G 2.5 2.0 1.0 1.2 11.5 ± 0.8 220 69 3 2.5 2.0 1.0 1.1 11.5 ± 0.8 215 69 4G 2.5 2.0 1.0 1.2 13 ± 0.8 265 92 5G 2.5 2.0 1.0 1.3 14.5 ± 0.8 340 114 12 2.5 2.0 1.0 1.4 21 ± 1 650 275 3 4 2.55 1.0 1.2 13 ± 0.8 295 110 3G 4 2.55 1.0 1.2 13 ± 0.8 295 110 2 6 3.15 1.0 1.2 13.5 ± 0.8 310 109 3 6 3.15 1.0 1.2 14.5 ± 0.8 380 164

239

Page 247: Prysmian Draka - Marine & Offshore LV HV Cables

BU 1kV(3).doc 29.12.2006 10:42

Page 3 of 4

BU 0,6/1kV P17, Power cable, Unarmoured

www.drakaMOG.com Subject to change without prior notice

Number of elements

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

5G 6 3.15 1.0 1.3 17.5 ± 0.8 580 272 3 10 4.05 1.0 1.4 16.5 ± 0.8 550 271 3 16 5.15 1.0 1.4 19 ± 0.8 780 433 3 25 6.45 1.2 1.5 22.5 ± 1 1160 688 3 35 7.65 1.2 1.7 26 ± 1 1550 927 3 50 9.0 1.4 1.9 30 ± 1.5 2120 1293 3 150 15.9 1.8 2.3 48 ± 2 5910 4020

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

801200 BU 0.6/1kV 1X 16mm² P17 BLACK - 7021528012002 - 801201 BU 0.6/1kV 1X 25mm² P17 BLACK - 7021528012019 - 801202 BU 0.6/1kV 1X 35mm² P17 BLACK - 7021528012026 - 801203 BU 0.6/1kV 1X 50mm² P17 BLACK - 7021528012033 1061203 801204 BU 0.6/1kV 1X 70mm² P17 BLACK - 7021528012040 - 801205 BU 0.6/1kV 1X 95mm² P17 BLACK - 7021528012057 1061205 801206 BU 0.6/1kV 1X 120mm² P17 BLACK - 7021528012064 - 801207 BU 0.6/1kV 1X 150mm² P17 BLACK - 7021528012071 1061207 801208 BU 0.6/1kV 1X 185mm² P17 BLACK - 7021528012088 - 801214 BU 0.6/1kV 1X 10mm² P17 BLACK - 7021528012149 - 801215 BU 0,6/1KV 2X 1,5 MM2 P17 BLACK - 7021528012156 - 801216 BU 0.6/1kV 3G 1.5mm² P17 BLACK - 7021528012163 - 801218 BU 0,6/1KV 3X 1,5 MM2 P17 BLACK - 7021528012187 - 801225 BU 0,6/1KV 7X 1,5 MM2 P17 BLACK - 7021528012255 - 801228 BU 0.6/1kV 19X 1.5mm² P17 BLACK - 7021528012286 - 801233 BU 0.6/1kV 2X 2.5mm² P17 BLACK - 7021528012330 - 801234 BU 0.6/1kV 3G 2.5mm² P17 BLACK Yes 7021528012347 - 801236 BU 0,6/1KV 3X 2,5 MM2 P17 BLACK - 7021528012361 - 801237 BU 0.6/1kV 4G 2.5mm² P17 BLACK - 7021528012378 - 801240 BU 0.6/1kV 5G 2.5mm² P17 BLACK - 7021528012408 - 801245 BU 0.6/1kV 12X 2.5mm² P17 BLACK - 7021528012453 - 801253 BU 0,6/1KV 3X 4 MM2 P17 BLACK - 7021528012538 - 801254 BU 0.6/1kV 3G 4mm² P17 BLACK - 7021528012545 - 801259 BU 0,6/1KV 2X 6 MM2 P17 BLACK - 7021528012590 - 801261 BU 0,6/1KV 3X 6 MM2 P17 BLACK - 7021528012613 - 801263 BU 0,6/1KV 5G 6 mm² P17 BLACK - 7021528012637 - 801267 BU 0,6/1KV 3X 10 MM2 P17 BLACK - 7021528012675 - 801273 BU 0,6/1KV 3X 16 MM2 P17 BLACK - 7021528012736 - 801279 BU 0,6/1KV 3X 25 mm² P17 BLACK - 7021528012798 - 801286 BU 0,6/1KV 3X 35 mm² P17 BLACK - 7021528012866 - 801292 BU 0,6/1KV 3X 50 mm² P17 BLACK - 7021528012927 - 801298 BU 0,6/1KV 3X 150 mm² P17 BLACK - 7021528012989 -

Electrical values power cables Number of elements

Cross section

core, mm²

Max. conductor resistance at

20°C, Ohm/km

Max. conductor resistance at

90°C, Ohm/km

Reactance at 50Hz,

Ohm/km

Reactance at 60Hz,

Ohm/km

Current rating IEC 60092-352

Table B.4, Ampere

Short circuit rating 1 second, Ampere

1 16 1.16 1.48 0.100 0.120 96 2240 1 25 0.734 0.936 0.097 0.117 127 3500

240

Page 248: Prysmian Draka - Marine & Offshore LV HV Cables

BU 1kV(3).doc 29.12.2006 10:42

Page 4 of 4

BU 0,6/1kV P17, Power cable, Unarmoured

www.drakaMOG.com Subject to change without prior notice

Number of elements

Cross section

core, mm²

Max. conductor resistance at

20°C, Ohm/km

Max. conductor resistance at

90°C, Ohm/km

Reactance at 50Hz,

Ohm/km

Reactance at 60Hz,

Ohm/km

Current rating IEC 60092-352

Table B.4, Ampere

Short circuit rating 1 second, Ampere

1 35 0.529 0.675 0.093 0.111 157 4900 1 50 0.391 0.499 0.091 0.109 196 7000 1 70 0.27 0.344 0.087 0.105 242 9800 1 95 0.195 0.249 0.085 0.102 293 13300 1 120 0.154 0.196 0.084 0.100 339 16800 1 150 0.126 0.161 0.083 0.100 389 21000 1 185 0.1 0.128 0.083 0.100 444 25900 1 10 1.84 2.35 0.108 0.130 72 1400 2 1.5 12.2 15.6 0.115 0.138 20 210 3G 1.5 12.2 15.6 0.115 0.138 20 210 3 1.5 12.2 15.6 0.115 0.138 16 210 7 1.5 12.2 15.6 0.115 0.138 12 210 19 1.5 12.2 15.6 0.115 0.138 8.5 210 2 2.5 7.56 9.64 0.107 0.129 26 350 3G 2.5 7.56 9.64 0.107 0.129 26 350 3 2.5 7.56 9.64 0.107 0.129 21 350 4G 2.5 7.56 9.64 0.107 0.129 21 350 5G 2.5 7.56 9.64 0.107 0.129 21 350 12 2.5 7.56 15.6 0.115 0.138 13 350 3 4 4.7 5.99 0.100 0.120 28 560 3G 4 4.7 9.64 0.107 0.129 34 560 2 6 3.11 3.97 0.094 0.112 44 840 3 6 3.11 3.97 0.094 0.112 36 840 5G 6 3.11 3.97 0.094 0.112 36 840 3 10 1.84 2.35 0.088 0.105 50 1400 3 16 1.16 1.48 0.082 0.099 67 2240 3 25 0.734 0.936 0.079 0.095 89 3500 3 35 0.529 0.675 0.078 0.094 110 4900 3 50 0.391 0.499 0.078 0.093 137 7000 3 150 0.126 0.161 0.073 0.088 272 21000

Ambient temperature correction factors Ambient Temp °C 35 40 45 50 55 60 65 70 75 80 Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

241

Page 249: Prysmian Draka - Marine & Offshore LV HV Cables

BU(c) 250V(3).doc 29.12.2006 10:20

Page 1 of 3

BU(c) 250V S14 Instrumentation cable, Unarmoured

Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant

BU(c) 250VMGT/EPR/EVA

NEK 606 CodeS14 Operating temperature : 90°CO perating Voltage : 250V

Application

Fixed installation for instrumentation, communication, control and alarm systems in both EX-(Zone 2) and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in

EK 606. N

Standards applied

IEC 60092-376 (2003-05) - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60331-21 - Fire Resistant IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)

Pair / Triple / Quad twisting

Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.

Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour.

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text "meter" "år" DRAKA NORSK KABEL BU(c) 250V S14 8 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-21 IEC 60332-3-22

Outer sheath colour

Grey or Blue

Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Quad Black - Light Blue - Brown - Grey

www.drakaMOG.com Subject to change without prior notice

242

Page 250: Prysmian Draka - Marine & Offshore LV HV Cables

BU(c) 250V(3).doc 29.12.2006 10:20

Page 2 of 3

BU(c) 250V S14 Instrumentation cable, Unarmoured

Range and dimensions

www.drakaMOG.com Subject to change without prior notice

Number of elements

No of cores in element

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

2 2 0.75 1.1 0.6 1.1 10.5 ± 0.8 155 33 4 2 0.75 1.1 0.6 1.2 12.5 ± 0.8 235 61 8 2 0.75 1.1 0.6 1.4 17.5 ± 0.8 450 116 12 2 0.75 1.1 0.6 1.5 19.5 ± 0.8 590 172 16 2 0.75 1.1 0.6 1.6 21.5 ± 1 740 228 19 2 0.75 1.1 0.6 1.7 23 ± 1 850 269 24 2 0.75 1.1 0.6 1.8 26.5 ± 1 1060 339 2 3 0.75 1.1 0.6 1.2 12 ± 0.8 205 47 4 3 0.75 1.1 0.6 1.3 14.5 ± 0.8 320 89 8 3 0.75 1.1 0.6 1.5 19.5 ± 0.8 590 173 12 3 0.75 1.1 0.6 1.6 22.5 ± 1 800 257 16 3 0.75 1.1 0.6 1.7 24.5 ± 1 1030 341 24 3 0.75 1.1 0.6 2 30.5 ± 1.5 1500 509 2 2 1.5 1.6 0.7 1.2 13 ± 0.8 230 63 4 2 1.5 1.6 0.7 1.3 15.5 ± 0.8 360 118 8 2 1.5 1.6 0.7 1.5 21 ± 1 680 229 12 2 1.5 1.6 0.7 1.7 24.5 ± 1 940 340 16 2 1.5 1.6 0.7 1.8 26.5 ± 1 1200 451 24 2 1.5 1.6 0.7 2.1 33 ± 1.5 1770 673 2 3 1.5 1.6 0.7 1.3 15 ± 0.8 310 91 4 3 1.5 1.6 0.7 1.4 17.5 ± 0.8 500 174 8 3 1.5 1.6 0.7 1.6 23.5 ± 1 930 341 12 3 1.5 1.6 0.7 1.8 28 ± 1 1310 509 16 3 1.5 1.6 0.7 1.9 30.5 ± 1.5 1680 677 24 3 1.5 1.6 0.7 2.2 37.5 ± 1.5 2480 1011

Electrical values instrumentation cables

Type Capacitance, approx. (nF/km)

Inductance, approx, (mH/km)

Resistance at 20°C, max. (Ohm/km)

L/R ratio, (microH/Ohm)

Unshielded pair 0,75 mm² 100 0,67 24,8 14,3 Unshielded triple 0,75 mm² 100 0,67 24,8 14,3 Unshielded pair 1,5 mm² 110 0,63 12,2 26,6 Unshielded triple 1,5 mm² 110 0,63 12,2 26,6 Unshielded pair 2,5 mm² 125 0,59 7,56 39,0 Unshielded triple 2,5 mm² 125 0,59 7,56 39,0

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

896806 BU(C) 250V 2PAIR 0.75mm² S14 GREY - 7021528968064 - 896818 BU(C) 250V 4PAIR 0.75mm² S14 GREY - 7021528968187 - 896830 BU(C) 250V 8PAIR 0.75mm² S14 GREY - 7021528968309 - 896836 BU(C) 250V 12PAIR 0.75mm² S14 GREY - 7021528968361 - 896842 BU(C) 250V 16PAIR 0.75mm² S14 GREY - 7021528968422 - 896845 BU(C) 250V 19PAIR 0.75mm² S14 GREY - 7021528968453 - 896848 BU(C) 250V 24PAIR 0.75mm² S14 GREY - 7021528968484 -

243

Page 251: Prysmian Draka - Marine & Offshore LV HV Cables

BU(c) 250V(3).doc 29.12.2006 10:20

Page 3 of 3

BU(c) 250V S14 Instrumentation cable, Unarmoured

www.drakaMOG.com Subject to change without prior notice

Part number Description Sheath Colour Stock item EAN No. DNK EL No.896866 BU(C) 250V 2TRIP 0.75mm² S14 GREY - 7021528968668 - 896878 BU(C) 250V 4TRIP 0.75mm² S14 GREY - 7021528968781 - 896890 BU(C) 250V 8TRIP 0.75mm² S14 GREY - 7021528968903 - 896896 BU(C) 250V 12TRIP 0.75mm² S14 GREY - 7021528968965 - 896902 BU(C) 250V 16TRIP 0.75mm² S14 GREY - 7021528969023 - 896908 BU(C) 250V 24TRIP 0.75mm² S14 GREY - 7021528969085 - 897006 BU(C) 250V 2PAIR 1.5mm² S14 GREY - 7021528970067 - 897018 BU(C) 250V 4PAIR 1.5mm² S14 GREY - 7021528970180 - 897030 BU(C) 250V 8PAIR 1.5mm² S14 GREY - 7021528970302 - 897036 BU(C) 250V 12PAIR 1.5mm² S14 GREY - 7021528970364 - 897042 BU(C) 250V 16PAIR 1.5mm² S14 GREY - 7021528970425 - 897048 BU(C) 250V 24PAIR 1.5mm² S14 GREY - 7021528970487 - 897066 BU(C) 250V 2TRIP 1.5mm² S14 GREY - 7021528970661 - 897078 BU(C) 250V 4TRIP 1.5mm² S14 GREY - 7021528970784 - 897090 BU(C) 250V 8TRIP 1.5mm² S14 GREY - 7021528970906 - 897096 BU(C) 250V 12TRIP 1.5mm² S14 GREY - 7021528970968 - 897102 BU(C) 250V 16TRIP 1.5mm² S14 GREY - 7021528971026 - 897108 BU(C) 250V 24TRIP 1.5mm² S14 GREY - 7021528971088 -

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

244

Page 252: Prysmian Draka - Marine & Offshore LV HV Cables

BU(i) 250V(3).doc 29.12.2006 10:26

Page 1 of 3

BU(i) 250V S13 Instrumentation cable, Unarmoured

Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant

BU(i) 250VMGT/EPR/EVA

NEK 606 CodeS13

Operating temperature : 90°CO perating Voltage : 250V

Application

Fixed installation for instrumentation, communication, control and alarm systems in both EX-(Zone 2) and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in

EK 606. N

Standards applied

IEC 60092-376 (2003-05) - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame RetardantIEC 60332-3-22 - Flame RetardantIEC 60331-21 - Fire Resistant IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)

Pair / Triple / Quad twisting

Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.

Lay up / Shielding

Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape.

Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour.

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text "meter" "år" DRAKA NORSK KABEL BU(i) 250V S13 8 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-21 IEC 60332-3-22

Outer sheath colour

Grey or Blue

www.drakaMOG.com Subject to change without prior notice

245

Page 253: Prysmian Draka - Marine & Offshore LV HV Cables

BU(i) 250V(3).doc 29.12.2006 10:26

Page 2 of 3

BU(i) 250V S13 Instrumentation cable, Unarmoured

Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Quad Black - Light Blue - Brown - Grey

Range and dimensions

www.drakaMOG.com Subject to change without prior notice

Number of elements

No of cores in element

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 2 0.75 1.1 0.6 1 7.5 ± 0.5 95 18.5 1 2 0.75 1.1 0.6 1 7.5 ± 0.5 95 18.5 2 2 0.75 1.1 0.6 1.2 11 ± 0.8 170 37 2 2 0.75 1.1 0.6 1.2 11 ± 0.8 170 37 4 2 0.75 1.1 0.6 1.2 13 ± 0.8 265 74 8 2 0.75 1.1 0.6 1.4 17.5 ± 0.8 510 147 12 2 0.75 1.1 0.6 1.6 21 ± 1 720 220 16 2 0.75 1.1 0.6 1.7 23.5 ± 1 920 293 24 2 0.75 1.1 0.6 1.9 29 ± 1 1340 440 1 3 0.75 1.1 0.6 1 7.5 ± 0.5 110 26 2 3 0.75 1.1 0.6 1.2 12 ± 0.8 205 51 4 3 0.75 1.1 0.6 1.3 14 ± 0.8 350 102 8 3 0.75 1.1 0.6 1.5 19.5 ± 0.8 650 203 12 3 0.75 1.1 0.6 1.7 23.5 ± 1 930 305 16 3 0.75 1.1 0.6 1.8 26 ± 1 1210 407 24 3 0.75 1.1 0.6 2.1 32.5 ± 1.5 1770 610 1 2 1.5 1.6 0.7 1 8.5 ± 0.5 135 35 1 2 1.5 1.6 0.7 1 8.5 ± 0.5 135 35 2 2 1.5 1.6 0.7 1.3 13.5 ± 0.8 250 69 2 2 1.5 1.6 0.7 1.3 13.5 ± 0.8 250 69 4 2 1.5 1.6 0.7 1.4 16 ± 0.8 420 138 8 2 1.5 1.6 0.7 1.6 22 ± 1 790 275 12 2 1.5 1.6 0.7 1.7 26 ± 1 1100 412 12 2 1.5 1.6 0.7 1.7 26 ± 1 1100 412 16 2 1.5 1.6 0.7 1.9 29.5 ± 1 1460 549 24 2 1.5 1.6 0.7 2.2 36.5 ± 1.5 2160 824 1 3 1.5 1.6 0.7 1.1 9.5 ± 0.5 165 49 1 3 1.5 1.6 0.7 1.1 9.5 ± 0.5 165 49 2 3 1.5 1.6 0.7 1.3 14.5 ± 0.8 320 97 4 3 1.5 1.6 0.7 1.4 17.5 ± 0.8 540 194 8 3 1.5 1.6 0.7 1.7 23.5 ± 1 1030 387 12 3 1.5 1.6 0.7 1.9 29 ± 1 1480 582 16 3 1.5 1.6 0.7 2 32.5 ± 1.5 1920 775 24 3 1.5 1.6 0.7 2.4 40.5 ± 2 2880 1163 1 2 2.5 2 0.7 1.1 9.5 ± 0.5 170 54

Electrical values instrumentation cables

Type Capacitance, approx. (nF/km)

Inductance, approx, (mH/km)

Resistance at 20°C, max. (Ohm/km)

L/R ratio, (microH/Ohm)

Shielded pair 0,75 mm² 110 0,67 24,8 14,3 Shielded triple 0,75 mm² 110 0,67 24,8 14,3 Shielded pair 1,5 mm² 125 0,63 12,2 26,6

246

Page 254: Prysmian Draka - Marine & Offshore LV HV Cables

BU(i) 250V(3).doc 29.12.2006 10:26

Page 3 of 3

BU(i) 250V S13 Instrumentation cable, Unarmoured

www.drakaMOG.com Subject to change without prior notice

Type Capacitance, approx. (nF/km)

Inductance, approx, (mH/km)

Resistance at 20°C, max. (Ohm/km)

L/R ratio, (microH/Ohm)

Shielded triple 1,5 mm² 125 0,63 12,2 26,6 Shielded pair 2,5 mm² 145 0,59 7,56 39,0 Shielded triple 2,5 mm² 145 0,59 7,56 39,0

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

896200 BU(I) 250V 1PAIR 0.75mm² S13 GREY - 7021528962000 - 896201 BU(I) 250V 1PAIR 0.75mm² S13 BLUE - 7021528962017 - 896206 BU(I) 250V 2PAIR 0.75mm² S13 GREY - 7021528962062 - 896207 BU(I) 250V 2PAIR 0.75mm² S13 BLUE - 7021528962079 - 896218 BU(I) 250V 4PAIR 0.75mm² S13 GREY - 7021528962185 - 896230 BU(I) 250V 8PAIR 0.75mm² S13 GREY - 7021528962307 - 896236 BU(I) 250V 12PAIR 0.75mm² S13 GREY - 7021528962369 - 896242 BU(I) 250V 16PAIR 0.75mm² S13 GREY - 7021528962420 - 896248 BU(I) 250V 24PAIR 0.75mm² S13 GREY - 7021528962482 - 896260 BU(I) 250V 1TRIP 0.75mm² S13 GREY - 7021528962604 - 896266 BU(I) 250V 2TRIP 0.75mm² S13 GREY - 7021528962666 - 896278 BU(I) 250V 4TRIP 0.75mm² S13 GREY - 7021528962789 - 896290 BU(I) 250V 8TRIP 0.75mm² S13 GREY - 7021528962901 - 896296 BU(I) 250V 12TRIP 0.75mm² S13 GREY - 7021528962963 - 896302 BU(I) 250V 16TRIP 0.75mm² S13 GREY - 7021528963021 - 896308 BU(I) 250V 24TRIP 0.75mm² S13 GREY - 7021528963083 - 896400 BU(I) 250V 1PAIR 1.5mm² S13 GREY - 7021528964004 - 896401 BU(I) 250V 1PAIR 1.5mm² S13 BLUE - 7021528964011 - 896406 BU(I) 250V 2PAIR 1.5mm² S13 GREY - 7021528964066 - 896407 BU(I) 250V 2PAIR 1.5mm² S13 BLUE - 7021528964073 - 896418 BU(I) 250V 4PAIR 1.5mm² S13 GREY - 7021528964189 - 896430 BU(I) 250V 8PAIR 1.5mm² S13 GREY - 7021528964301 - 896436 BU(I) 250V 12PAIR 1.5mm² S13 GREY - 7021528964363 - 896437 BU(I) 250V 12PAIR 1.5mm² S13 BLUE - 7021528964370 - 896442 BU(I) 250V 16PAIR 1.5mm² S13 GREY - 7021528964424 - 896448 BU(I) 250V 24PAIR 1.5mm² S13 GREY - 7021528964486 - 896460 BU(I) 250V 1TRIP 1.5mm² S13 GREY - 7021528964608 - 896461 BU(I) 250V 1TRIP 1.5mm² S13 BLUE - 7021528964615 - 896466 BU(I) 250V 2TRIP 1.5mm² S13 GREY - 7021528964660 - 896478 BU(I) 250V 4TRIP 1.5mm² S13 GREY - 7021528964783 - 896490 BU(I) 250V 8TRIP 1.5mm² S13 GREY - 7021528964905 - 896496 BU(I) 250V 12TRIP 1.5mm² S13 GREY - 7021528964967 - 896502 BU(I) 250V 16TRIP 1.5mm² S13 GREY - 7021528965025 - 896508 BU(I) 250V 24TRIP 1.5mm² S13 GREY - 7021528965087 - 896600 BU(I) 250V 1PAIR 2.5mm² S13 GREY - 7021528966008 -

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

247

Page 255: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 12_20_24kV(3).doc 29.12.2006 11:19

Page 1 of 3

FlexFlame RFOU 12/20(24) kV P19/P21 Power cable

Flame retardant halogen-free medium voltage (MV) cable. Mud resistant

RFOU 12/20(24) kVEPR/EPR/TCWB/EVA

NEK 606 CodeP19/P21 Operating temperature : 90°CO perating Voltage : 12/20(24) kV

Application

Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in

reas exposed to MUD and drilling/cleaning fluids. a

Standards applied

IEC 60092-354 - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

www.drakaMOG.com Subject to change without prior notice

Code Letter

Conductor Tinned stranded and compressed copper (STCC), IEC 60228 class 2 Conductor screen semiconductive

Semiconductive layer (EP-rubber)

Insulation R EP-rubber, IEC 60092-351 (EPR) Insulation screen semicoductive

Semiconductive layer (EP-rubber)

Lay up / Shielding Cores are laid up together. Cores are identified by White, Black or Red threads under and over the metallic screen on each conductor.

Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner covering PET tape Armour/screen O Tinned annealed copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "year" DRAKA NORSK KABEL RFOU 12/20(24)KV P19/P21 3 x 95/50 mm2 IEC 60332-3-22

Outer sheath colour Red

248

Page 256: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 12_20_24kV(3).doc 29.12.2006 11:19

Page 2 of 3

FlexFlame RFOU 12/20(24) kV P19/P21 Power cable

Range and dimensions

Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 16 13 5.2 5.5 1.0 22.5 ±1.0 0.3 1.6 28 ± 1.5 1200 495

1 25 13 6.5 5.5 1.0 24 ±1.0 0.3 1.7 29.5 ± 1.5 1300 561

1 35 13 7.4 5.5 1.2 25 ±1.5 0.3 1.8 31 ± 2 1450 671 1 50 15 8.8 5.5 1.2 26.5 ±1.5 0.3 2.0 32.5 ± 2 1700 811 1 70 13 10.3 5.5 1.2 28 ± 1.5 0.3 2.1 34 ± 2.0 2000 1001 1 95 17 12.1 5.5 1.2 30 ±1.5 0.3 2.1 36 ± 2 2400 1210 1 120 15 13.6 5.5 1.3 31.5 ±1.5 0.3 2.1 38 ± 2 2650 1491 1 150 15 15.1 5.5 1.3 33 ±1.5 0.3 2.2 40 ± 2.5 3000 1835

1 185 18 16.8 5.5 1.4 35 ±1.5 0.3 2.2 41.5 ± 2.5 3500 2201

1 240 23 19.1 5.5 1.4 37.5 ±1.5 0.3 2.4 45.0 ± 2.5 4350 2915

1 300 28 21.5 5.5 1.4 41.0 ±2.0 0.3 2.6 47.0 ± 3.0 5200 3640

3 16 31 5.2 5.5 1.4 48 ± 2.0 0.4 2.6 55.5 ± 3.0 9300 4112

3 25 35 6.5 5.5 1.4 51 ± 2.0 0.4 2.7 58.5 ± 3.0 4950 1558

3 35 35 7.4 5.5 1.4 53 ± 2.0 0.4 2.8 61 ± 3.0 5500 1885

3 50 35 8.8 5.5 1.8 57.0 ± 2.0 0.4 3.0 65.5 ±

3.5 6500 2276

3 70 35 10.3 5.5 1.8 60 ± 2.5 0.4 3.1 68.5 ± 3.5 7500 2979

3 95 50 12.1 5.5 2.0 64.5 ± 3.0 0.5 3.3 73.5 ±

4.0 9300 4112

3 120 60 13.6 5.5 2.0 67.5 ± 3.0 0.5 3.4 77 ± 4.0 10250 4761

3 150 75 15.1 5.5 2.0 71.0 ± 3.0 0.5 3.5 80.0 ±

4.5 11700 5822

3 185 45 16.8 5.5 2.0 75.0 ± 3.5 0.5 3.7 85.0 ±

4.5 12950 6615

3 240 55 19.1 5.5 2.2 79.5 ± 3.5 0.5 3.9 90.0 ±

4.5 15900 8797

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

804100 RFOU 12/20KV 1X 16/13mm² P19 RED - 7021528041002 - 804101 RFOU 12/20KV 1X 25/13mm² P19 RED - 7021528041019 - 804102 RFOU 12/20KV 1X 35/13mm² P19 RED - 7021528041026 - 804103 RFOU 12/20KV 1X 50/15mm² P19 RED - 7021528041033 - 804104 RFOU 12/20KV 1X 70/13mm² P19 RED - 7021528041040 - 804105 RFOU 12/20KV 1X 95/17mm² P19 RED - 7021528041057 - 804106 RFOU 12/20KV 1X120/15mm² P19 RED - 7021528041064 - 804107 RFOU 12/20KV 1X150/15mm² P19 RED - 7021528041071 - 804108 RFOU 12/20KV 1X185/18mm² P19 RED - 7021528041088 - 804109 RFOU 12/20KV 1X240/23mm² P19 RED - 7021528041095 - 804110 RFOU 12/20KV 1X300/28mm² P19 RED - 7021528041101 - 804120 RFOU 12/20KV 3X 16/31mm² P19 RED - 7021528041200 - 804121 RFOU 12/20KV 3X 25/35mm² P19 RED - 7021528041217 -

www.drakaMOG.com Subject to change without prior notice

249

Page 257: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 12_20_24kV(3).doc 29.12.2006 11:19

Page 3 of 3

FlexFlame RFOU 12/20(24) kV P19/P21 Power cable

www.drakaMOG.com Subject to change without prior notice

Part number Description Sheath Colour Stock item EAN No. DNK EL No.804122 RFOU 12/20KV 3X 35/35mm² P19 RED - 7021528041224 - 804123 RFOU 12/20KV 3X 50/35mm² P19 RED - 7021528041231 - 804124 RFOU 12/20KV 3X 70/35mm² P19 RED - 7021528041248 - 804125 RFOU 12/20KV 3X 95/50mm² P19 RED - 7021528041255 - 804126 RFOU 12/20KV 3X120/60mm² P19 RED - 7021528041262 - 804127 RFOU 12/20KV 3X150/75mm² P19 RED - 7021528041279 - 804128 RFOU 12/20KV 3X185/45mm² P19 RED - 7021528041286 - 804129 RFOU 12/20KV 3X240/55mm² P19 RED - 7021528041293 -

Electrical values power cables Number

of elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type 2

Max. conductor resistance at 20°C, Ohm/km

Max. conductor resistance at 90°C, Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Capacitans per phase,

nF/km

Current rating IEC

60092-352

Table B.4,

Ampere

Short circuit

rating 1 second, Ampere

1 16 13 STCC 1.16 1.479 0.164 0.197 170 96 2240 1 25 13 STCC 0.734 0.936 0.154 0.185 190 127 3500 1 35 13 STCC 0.529 0.675 0.149 0.178 200 157 4900 1 50 15 STCC 0.391 0.499 0.140 0.169 220 196 7000 1 70 13 STCC 0.270 0.344 0.133 0.160 250 242 9800 1 95 17 STCC 0.195 0.249 0.127 0.152 270 293 13300 1 120 15 STCC 0.154 0.196 0.124 0.149 300 339 16800 1 150 15 STCC 0.126 0.161 0.119 0.142 320 389 21000 1 185 18 STCC 0.100 0.128 0.116 0.139 340 444 25900 1 240 23 STCC 0.0762 0.0972 0.112 0.134 380 522 33600 1 300 28 STCC 0.0607 0.0774 0.108 0.130 410 601 42000 3 16 31 STCC 1.16 1.48 0.143 0.172 170 67 2240 3 25 35 STCC 0.734 0.936 0.133 0.160 190 89 3500 3 35 35 STCC 0.529 0.675 0.128 0.153 200 110 4900 3 50 35 STCC 0.391 0.499 0.121 0.145 220 137 7000 3 70 35 STCC 0.270 0.344 0.115 0.135 250 169 9800 3 95 50 STCC 0.195 0.249 0.109 0.131 270 205 13300 3 120 60 STCC 0.154 0.196 0.105 0.126 300 237 16800 3 150 75 STCC 0.126 0.161 0.102 0.122 320 272 21000 3 185 45 STCC 0.100 0.128 0.099 0.118 340 311 25900 3 240 55 STCC 0.0762 0.0972 0.095 0.114 380 365 33600

Ambient temperature correction factors Ambient Temp °C 35 40 45 50 55 60 65 70 75 80 Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 15 x D 9 x D 50 N /mm² -20°C

250

Page 258: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 1kV(4).doc 03/06/2008 08:33:00

Page 1 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable

www.drakaMOG.com Subject to change without prior notice

Flame retardant halogen-free power cable. Mud resistant

RFOU 0,6/1kV EPR/EPR/TCWB/EVA NEK 606 CodeP1/P8 Operating temperature : 90°C Operating Voltage : 0,6/1kV

Application Fixed installation for power,control and lighting in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK 606.

Standards applied

IEC 60092-353 - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation R EP-rubber, IEC 60092-351 (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner covering

PET tape

Armour/screen O Tinned annealed copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "year" DRAKA 01 RFOU 0,6/1KV P1/P8 3 x 35/16 mm2 IEC 60332-3-22 ETL Classified No. 3067229

Manufacturing unit DRAKA 01 = Draka Norsk Kabel, Outer sheath colour Black

251

Page 259: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 1kV(4).doc 03/06/2008 08:33:00

Page 2 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable

www.drakaMOG.com Subject to change without prior notice

Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 16 2.5 5.15 1.0 1.1 9.5 ± 0.5 0.2 1.2 13 ± 0.8 360 190

1 25 4 6.45 1.2 1.1 11.5 ± 0.8 0.2 1.2 14.5 ±

0.8 490 283

1 35 6 7.65 1.2 1.1 12.5 ± 0.8 0.3 1.3 16 ± 0.8 650 408

1 50 6 9.0 1.4 1.1 14.5 ± 0.8 0.3 1.4 18.5 ±

0.8 830 528

1 70 10 10.85 1.4 1.1 16.5 ± 0.8 0.3 1.4 20.5 ± 1 1100 744

1 95 10 12.60 1.6 1.1 18.5 ± 0.8 0.3 1.5 23 ± 1 1380 961

1 120 10 14.20 1.6 1.2 20.5 ± 1 0.3 1.6 25 ± 1 1710 1224 1 150 10 15.90 1.8 1.2 22.5 ± 1 0.3 1.6 27 ± 1 2040 1485 1 185 10 17.70 2.0 1.2 24.5 ± 1 0.3 1.7 29.5 ± 1 2480 1837

1 240 16 20.15 2.2 1.2 27.5 ± 1 0.3 1.8 32.5 ± 1.5 3130 2372

1 300 16 22.60 2.4 1.2 30.5 ± 1.5 0.3 1.9 35.5 ±

1.5 3830 2952

2 1.5 4 1.6 1.0 1.1 9.5 ± 0.5 0.2 1.2 12.5 ± 0.8 270 80

3G 1.5 - 1.6 1.0 1.1 10 ± 0.8 0.2 1.2 13.5 ± 0.8 295 94

4G 1.5 - 1.6 1.0 1.1 11 ± 0.8 0.3 1.3 14.5 ± 0.8 380 139

3 1.5 4 1.6 1.0 1.1 10 ± 0.8 0.2 1.2 13.5 ± 0.8 295 94

4 1.5 6 1.6 1.0 1.1 11 ± 0.8 0.3 1.3 14.5 ± 0.8 380 139

5 1.5 6 1.6 1.0 1.1 12 ± 0.8 0.3 1.3 15.5 ± 0.8 440 170

7 1.5 6 1.6 1.0 1.1 13 ± 0.8 0.3 1.3 17 ± 0.8 500 198

12 1.5 10 1.6 1.0 1.1 17.5 ± 0.8 0.3 1.5 21.5 ± 1 740 300

19 1.5 10 1.6 1.0 1.2 20.5 ± 1 0.3 1.6 25 ± 1 1020 413 27 1.5 10 1.6 1.0 1.2 24.5 ± 1 0.3 1.8 29.5 ± 1 1360 551

37 1.5 16 1.6 1.0 1.2 27.5 ± 1 0.3 1.9 32.5 ± 1.5 1720 716

5G 1.5 - 1.6 1.0 1.1 12 ± 0.8 0.3 1.3 15.5 ± 0.8 440 170

7G 1.5 - 1.6 1.0 1.1 13 ± 0.8 0.3 1.3 17 ± 0.8 500 197 2 2.5 4 2.0 1.0 1.1 10.5 ± 0.2 1.2 13.5 ± 320 98

252

Page 260: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 1kV(4).doc 03/06/2008 08:33:00

Page 3 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable

www.drakaMOG.com Subject to change without prior notice

Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

0.8 0.8

3G 2.5 - 2.0 1.0 1.1 11 ± 0.8 0.3 1.3 14.5 ± 0.8 390 152

3 2.5 6 2.0 1.0 1.1 11 ± 0.8 0.3 1.3 14.5 ± 0.8 390 152

4G 2.5 - 2.0 1.0 1.1 12 ± 0.8 0.3 1.3 16 ± 0.8 460 192 5G 2.5 - 2.0 1.0 1.1 13 ± 0.8 0.3 1.4 17 ± 0.8 530 215 4 2.5 6 2.0 1.0 1.1 12 ± 0.8 0.3 1.3 16 ± 0.8 460 192 5 2.5 6 2.0 1.0 1.1 13 ± 0.8 0.3 1.4 17 ± 0.8 530 215

7 2.5 6 2.0 1.0 1.1 14.5 ± 0.8 0.3 1.4 18.5 ±

0.8 630 277

12 2.5 10 2.0 1.0 1.2 19.5 ± 0.8 0.3 1.6 23.5 ± 1 950 424

19 2.5 10 2.0 1.0 1.2 23 ± 1 0.3 1.7 27.5 ± 1 1310 609

27 2.5 16 2.0 1.0 1.2 27.5 ± 1 0.3 1.9 32.5 ± 1.5 1760 817

37 2.5 16 2.0 1.0 1.4 31.5 ± 1.5 0.3 2 36.5 ±

1.5 2310 1074

4G 4 - 2.55 1.0 1.1 13.5 ± 0.8 0.3 1.4 17 ± 0.8 560 247

7G 2.5 - 2.0 1.0 1.1 14.5 ± 0.8 0.3 1.4 18.5 ±

0.8 630 276

2 4 6 2.55 1.0 1.1 11.5 ± 0.8 0.3 1.3 15 ± 0.8 410 157

3 4 6 2.55 1.0 1.1 12 ± 0.8 0.3 1.3 16 ± 0.8 480 210

4 4 6 2.55 1.0 1.1 13.5 ± 0.8 0.3 1.4 17 ± 0.8 560 247

5 4 6 2.55 1.0 1.1 14.5 ± 0.8 0.3 1.4 18.5 ±

0.8 660 299

3G 4 - 2.55 1.0 1.1 12 ± 0.8 0.3 1.3 16 ± 0.8 480 210

5G 4 - 2.55 1.0 1.1 14.5 ± 0.8 0.3 1.4 18.5 ±

0.8 660 299

2 6 6 3.15 1.0 1.1 12.5 ± 0.8 0.3 1.3 16.5 ±

0.8 500 209

3 6 6 3.15 1.0 1.1 13.5 ± 0.8 0.3 1.4 17.5 ±

0.8 590 264

4 6 6 3.15 1.0 1.1 15 ± 0.8 0.3 1.4 18.5 ± 0.8 700 334

4G 6 - 3.15 1.0 1.1 15 ± 0.8 0.3 1.4 18.5 ± 0.8 700 334

3G 6 - 3.15 1.0 1.1 13.5 ± 0.8 0.3 1.4 17.5 ±

0.8 590 264

5G 6 - 3.15 1.0 1.1 16.5 ± 0.8 0.3 1.5 20.5 ± 1 820 388

2 10 10 4.05 1.0 1.1 14.5 ± 0.8 0.3 1.4 18.5 ±

0.8 670 299

3 10 10 4.05 1.0 1.1 15.5 ± 0.8 0.3 1.4 19.5 ±

0.8 780 389

4 10 10 4.05 1.0 1.1 17 ± 0.8 0.3 1.5 21 ± 1 940 494

3G 10 - 4.05 1.0 1.1 15.5 ± 0.8 0.3 1.4 19.5 ±

0.8 780 387

5G 10 - 4.05 1.0 1.2 19 ± 0.8 0.3 1.5 23 ± 1 1130 600 4G 10 - 4.05 1.0 1.1 17 ± 0.8 0.3 1.5 21 ± 1 940 494

2 16 16 5.15 1.0 1.1 16.5 ± 0.8 0.4 1.5 21 ± 1 950 477

3 16 16 5.15 1.0 1.1 17.5 ± 0.8 0.4 1.5 22.5 ± 1 1120 621

4 16 16 5.15 1.0 1.2 20 ± 1 0.4 1.6 24.5 ± 1 1390 799

253

Page 261: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 1kV(4).doc 03/06/2008 08:33:00

Page 4 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable

www.drakaMOG.com Subject to change without prior notice

Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

4G 16 - 5.15 1.0 1.2 20 ± 1 0.3 1.6 24 ± 1 1310 727 5G 16 - 5.15 1.0 1.2 22 ± 1 0.3 1.6 26 ± 1 1530 873

3G 16 - 5.15 1.0 1.1 17.5 ± 0.8 0.3 1.5 22 ± 1 1050 566

2 25 16 6.45 1.2 1.2 20.5 ± 1 0.4 1.6 25.5 ± 1 1340 685 3 25 16 6.45 1.2 1.2 22 ± 1 0.3 1.6 26 ± 1 1560 887 4 25 16 6.45 1.2 1.2 24 ± 1 0.3 1.7 28.5 ± 1 1900 1116 4G 25 - 6.45 1.2 1.2 24 ± 1 0.3 1.7 28.5 ± 1 1880 1091 3G 25 - 6.45 1.2 1.2 22 ± 1 0.3 1.6 26 ± 1 1510 837

5G 25 - 6.45 1.2 1.2 26.5 ± 1 0.3 1.8 31.5 ± 1.5 2250 1345

2 35 16 7.65 1.2 1.2 23 ± 1 0.3 1.7 27.5 ± 1 1580 817 3 35 16 7.65 1.2 1.2 24.5 ± 1 0.3 1.7 29 ± 1 1920 1126

4 35 16 7.65 1.2 1.2 27 ± 1 0.3 1.8 31.5 ± 1.5 2360 1435

4G 35 - 7.65 1.2 1.2 27 ± 1 0.3 1.8 31.5 ± 1.5 2360 1435

5G 35 - 7.65 1.2 1.2 30 ± 1.5 0.3 1.9 35 ± 1.5 2840 1768 3 50 25 9.0 1.4 1.2 28.5 ± 1 0.4 1.9 34 ± 1.5 2660 1596

4 50 25 9.0 1.4 1.4 32 ± 1.5 0.4 2 37.5 ± 1.5 3290 2025

4G 50 - 9.0 1.4 1.4 32 ± 1.5 0.3 2 37 ± 1.5 3200 1939 5G 50 - 9.0 1.4 1.4 35 ± 1.5 0.4 2.1 41 ± 2 4000 2498

2 70 35 10.85 1.4 1.2 30.5 ± 1.5 0.6 1.9 36.5 ±

1.5 3010 1756

3 70 35 10.85 1.4 1.4 33 ± 1.5 0.5 2 39 ± 1.5 3690 2346

4 70 35 10.85 1.4 1.4 36.5 ± 1.5 0.5 2.2 43 ± 2 4540 2967

4G 70 - 10.85 1.4 1.4 36.5 ± 1.5 0.4 2.2 42.5 ± 2 4410 2839

5G 70 - 10.85 1.4 1.4 40.5 ± 2 0.4 2.3 46.5 ± 2 5280 3465 5 70 35 10.85 1.4 1.4 40.5 ± 2 0.4 2.3 46.5 ± 2 5360 3547 2 95 50 12.60 1.6 1.4 35 ± 1.5 0.6 2.1 41.5 ± 2 3940 2292

3 95 50 12.60 1.6 1.4 37.5 ± 1.5 0.5 2.2 43.5 ± 2 4790 3091

4 95 50 12.60 1.6 1.4 41.5 ± 2 0.5 2.4 48.5 ± 2 5980 3973 4G 95 - 12.60 1.6 1.4 41.5 ± 2 0.4 2.4 48 ± 2 5750 3749

5G 120 - 14.20 1.6 1.6 50.5 ± 2.5 0.5 2.7 58.5 ±

2.5 8580 5873

2 120 60 14.20 1.6 1.4 38 ± 1.5 0.6 2.2 45 ± 2 4790 2875 3 120 60 14.20 1.6 1.4 41 ± 2 0.6 2.3 48 ± 2 5930 3953

4 120 60 14.20 1.6 1.6 46 ± 2 0.6 2.5 53.5 ± 2.5 7410 5071

4G 120 - 14.20 1.6 1.6 46 ± 2 0.4 2.5 52.5 ± 2.5 7090 4754

4G 150 - 15.90 1.8 1.6 51 ± 2.5 0.5 2.7 58.5 ± 2.5 8700 5845

4G 185 - 17.7 2.0 1.8 56.5 ± 2.5 0.5 2.9 64.5 ± 3 10690 7238

4G 240 - 19.1 2.2 1.8 62 ± 2.5 0.4 2.8 72 ± 3.5 13650 10054 4 185 95 16.8 2.0 1.6 55 ± 2 0.6 2.8 64 ± 3 11350 6598 4 240 120 19.1 2.2 2.0 62 ± 2.5 0.6 3.0 72 ± 3.5 14800 8777

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

800000 RFOU 0.6/1kV 1X 16/2.5 P1/P8 BLACK - 7021528000009 - 800001 RFOU 0.6/1kV 1X 25/4mm² P1/P8 BLACK - 7021528000016 1044206

254

Page 262: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 1kV(4).doc 03/06/2008 08:33:00

Page 5 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable

www.drakaMOG.com Subject to change without prior notice

Part number Description Sheath Colour Stock item EAN No. DNK EL No. 800002 RFOU 0.6/1kV 1X 35/6mm² P1/P8 BLACK - 7021528000023 1044207 800003 RFOU 0.6/1kV 1X 50/6mm² P1/P8 BLACK - 7021528000030 1044208 800004 RFOU 0.6/1kV 1X 70/6mm² P1/P8 BLACK - 7021528000047 - 800005 RFOU 0.6/1kV 1X 95/10mm² P1/P8 BLACK - 7021528000054 1044210 800006 RFOU 0.6/1kV 1X 120/10 P1/P8 BLACK - 7021528000061 - 800007 RFOU 0.6/1kV 1X 150/10 P1/P8 BLACK - 7021528000078 1044211 800008 RFOU 0.6/1kV 1X 185/10 P1/P8 BLACK - 7021528000085 1044213 800009 RFOU 0.6/1kV 1X 240/16 P1/P8 BLACK - 7021528000092 1044214 800010 RFOU 0.6/1kV 1X 300/16 P1/P8 BLACK Yes 7021528000108 1044215 800015 RFOU 0.6/1kV 2X 1.5/4mm² P1/P8 BLACK Yes 7021528000153 1044220 800016 RFOU 0.6/1kV 3G 1.5mm² P1/P8 BLACK - 7021528000160 - 800017 RFOU 0.6/1kV 4G 1.5mm² P1/P8 BLACK - 7021528000177 - 800018 RFOU 0.6/1kV 3X 1.5/4mm² P1/P8 BLACK Yes 7021528000184 1044240 800019 RFOU 0.6/1kV 4X 1.5/6mm² P1/P8 BLACK Yes 7021528000191 1044260 800020 RFOU 0.6/1kV 5X 1.5/6mm² P1/P8 BLACK - 7021528000207 1044305 800021 RFOU 0.6/1kV 7X 1.5/6mm² P1/P8 BLACK Yes 7021528000214 1044307 800022 RFOU 0.6/1kV 12X 1.5/10 P1/P8 BLACK Yes 7021528000221 1044312 800023 RFOU 0.6/1kV 19X 1.5/10 P1/P8 BLACK - 7021528000238 1044319 800024 RFOU 0.6/1kV 27X 1.5/10 P1/P8 BLACK - 7021528000245 1044327 800025 RFOU 0.6/1kV 37X 1.5/16 P1/P8 BLACK - 7021528000252 1044337 800026 RFOU 0.6/1kV 5G 1.5mm² P1/P8 BLACK - 7021528000269 - 800028 RFOU 0.6/1kV 7G 1.5mm² P1/P8 BLACK - 7021528000283 - 800029 RFOU 0.6/1kV 2X 2.5/4mm² P1/P8 BLACK Yes 7021528000290 1044221 800030 RFOU 0.6/1kV 3G 2.5mm² P1/P8 BLACK - 7021528000306 - 800032 RFOU 0.6/1kV 3X 2.5/6mm² P1/P8 BLACK Yes 7021528000320 1044241 800033 RFOU 0.6/1kV 4G 2.5mm² P1/P8 BLACK - 7021528000337 - 800034 RFOU 0.6/1kV 5G 2.5mm² P1/P8 BLACK - 7021528000344 - 800035 RFOU 0.6/1kV 4X 2.5/6mm² P1/P8 BLACK Yes 7021528000351 1044261 800036 RFOU 0.6/1kV 5X 2.5/6mm² P1/P8 BLACK - 7021528000368 1044355 800037 RFOU 0.6/1kV 7X 2.5/6mm² P1/P8 BLACK - 7021528000375 1044357 800038 RFOU 0.6/1kV 12X 2.5/10 P1/P8 BLACK - 7021528000382 1044362 800039 RFOU 0.6/1kV 19X 2.5/10 P1/P8 BLACK - 7021528000399 1044369 800040 RFOU 0.6/1kV 27X 2.5/16 P1/P8 BLACK - 7021528000405 1044377 800041 RFOU 0.6/1kV 37X 2.5/16 P1/P8 BLACK - 7021528000412 1044387 800043 RFOU 0.6/1kV 4G 4mm² P1/P8 BLACK - 7021528000436 - 800044 RFOU 0.6/1kV 7G 2.5mm² P1/P8 BLACK - 7021528000443 - 800045 RFOU 0.6/1kV 2X 4/6mm² P1/P8 BLACK Yes 7021528000450 1044222 800046 RFOU 0.6/1kV 3X 4/6mm² P1/P8 BLACK Yes 7021528000467 1044242 800047 RFOU 0.6/1kV 4X 4/6mm² P1/P8 BLACK - 7021528000474 1044262 800048 RFOU 0.6/1kV 5X 4/6mm² P1/P8 BLACK - 7021528000481 - 800049 RFOU 0.6/1kV 3G 4mm² P1/P8 BLACK - 7021528000498 - 800050 RFOU 0.6/1kV 5G 4mm² P1/P8 BLACK - 7021528000504 - 800051 RFOU 0.6/1kV 2X 6/6mm² P1/P8 BLACK Yes 7021528000511 1044223 800052 RFOU 0.6/1kV 3X 6/6mm² P1/P8 BLACK Yes 7021528000528 1044243 800053 RFOU 0.6/1kV 4X 6/6mm² P1/P8 BLACK - 7021528000535 1044263 800054 RFOU 0.6/1kV 4G 6mm² P1/P8 BLACK - 7021528000542 - 800055 RFOU 0.6/1kV 3G 6mm² P1/P8 BLACK - 7021528000559 - 800056 RFOU 0.6/1kV 5G 6mm² P1/P8 BLACK - 7021528000566 - 800057 RFOU 0.6/1kV 2X 10/10mm² P1/P8 BLACK - 7021528000573 1044224 800058 RFOU 0.6/1kV 3X 10/10mm² P1/P8 BLACK Yes 7021528000580 1044244 800059 RFOU 0.6/1kV 4X 10/10mm² P1/P8 BLACK - 7021528000597 1044264 800060 RFOU 0.6/1kV 3G 10mm² P1/P8 BLACK - 7021528000603 - 800061 RFOU 0.6/1kV 5G 10mm² P1/P8 BLACK - 7021528000610 - 800062 RFOU 0.6/1kV 4G 10mm² P1/P8 BLACK - 7021528000627 - 800063 RFOU 0.6/1kV 2X 16/16mm² P1/P8 BLACK - 7021528000634 1044225 800064 RFOU 0.6/1kV 3X 16/16mm² P1/P8 BLACK Yes 7021528000641 1044245 800065 RFOU 0.6/1kV 4X 16/16mm² P1/P8 BLACK - 7021528000658 1044265 800066 RFOU 0.6/1kV 4G 16mm² P1/P8 BLACK - 7021528000665 - 800067 RFOU 0.6/1kV 5G 16mm² P1/P8 BLACK - 7021528000672 - 800068 RFOU 0.6/1kV 3G 16mm² P1/P8 BLACK - 7021528000689 - 800069 RFOU 0.6/1kV 2X 25/16mm² P1/P8 BLACK - 7021528000696 1044226

255

Page 263: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 1kV(4).doc 03/06/2008 08:33:00

Page 6 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable

www.drakaMOG.com Subject to change without prior notice

Part number Description Sheath Colour Stock item EAN No. DNK EL No. 800070 RFOU 0.6/1kV 3X 25/16mm² P1/P8 BLACK Yes 7021528000702 1044246 800071 RFOU 0.6/1kV 4X 25/16mm² P1/P8 BLACK Yes 7021528000719 1044266 800072 RFOU 0.6/1kV 4G 25mm² P1/P8 BLACK - 7021528000726 - 800073 RFOU 0.6/1kV 3G 25mm² P1/P8 BLACK - 7021528000733 - 800074 RFOU 0.6/1kV 5G 25mm² P1/P8 BLACK - 7021528000740 - 800075 RFOU 0.6/1kV 2X 35/16mm² P1/P8 BLACK - 7021528000757 - 800076 RFOU 0.6/1kV 3X 35/16mm² P1/P8 BLACK Yes 7021528000764 1044247 800077 RFOU 0.6/1kV 4X 35/16mm² P1/P8 BLACK - 7021528000771 1044267 800078 RFOU 0.6/1kV 4G 35mm² P1/P8 BLACK - 7021528000788 - 800079 RFOU 0.6/1kV 5G 35mm² P1/P8 BLACK - 7021528000795 - 800082 RFOU 0.6/1kV 3X 50/25mm² P1/P8 BLACK Yes 7021528000825 1044248 800083 RFOU 0.6/1kV 4X 50/25mm² P1/P8 BLACK Yes 7021528000832 1044268 800084 RFOU 0.6/1kV 4G 50mm² P1/P8 BLACK - 7021528000849 - 800085 RFOU 0.6/1kV 5G 50mm² P1/P8 BLACK - 7021528000856 - 800087 RFOU 0.6/1kV 2X 70/35mm² P1/P8 BLACK - 7021528000870 - 800088 RFOU 0.6/1kV 3X 70/35mm² P1/P8 BLACK Yes 7021528000887 1044249 800089 RFOU 0.6/1kV 4X 70/35mm² P1/P8 BLACK - 7021528000894 1044269 800090 RFOU 0.6/1kV 4G 70mm² P1/P8 BLACK - 7021528000900 - 800091 RFOU 0.6/1kV 5G 70mm² P1/P8 BLACK - 7021528000917 - 800092 RFOU 0.6/1kV 5X 70/35mm² P1/P8 BLACK - 7021528000924 - 800094 RFOU 0.6/1kV 2X 95/50mm² P1/P8 BLACK - 7021528000948 - 800095 RFOU 0.6/1kV 3X 95/50mm² P1/P8 BLACK Yes 7021528000955 1044250 800096 RFOU 0.6/1kV 4X 95/50mm² P1/P8 BLACK Yes 7021528000962 1044270 800097 RFOU 0.6/1kV 4G 95mm² P1/P8 BLACK - 7021528000979 - 800099 RFOU 0.6/1kV 5G 120mm² P1/P8 BLACK - 7021528000993 - 800100 RFOU 0.6/1kV 2X 120/60 P1/P8 BLACK - 7021528001006 - 800101 RFOU 0.6/1kV 3X 120/60 P1/P8 BLACK Yes 7021528001013 1044251 800105 RFOU 0.6/1kV 4X 120/60 P1/P8 BLACK - 7021528001051 - 800106 RFOU 0.6/1kV 4G 120mm² P1/P8 BLACK - 7021528001068 - 800108 RFOU 0.6/1kV 4G 150mm² P1/P8 BLACK - 7021528001082 - 800110 RFOU 0.6/1kV 4G 185mm² P1/P8 BLACK - 7021528001105 - 803904 RFOU 0.6/1kV 4G 240mm2 P1/P8 BLACK - 7021528039047 - 803905 RFOU 0.6/1kV 4X 185/95 P1/P8 BLACK - 7021528039054 - 803906 RFOU 0.6/1kV 4X 240/120 P1/P8 BLACK - 7021528039061 -

Electrical values power cables Number

of elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type 2

Max. conductor

resistance at 20°C,

Ohm/km

Max. conductor

resistance at 90°C,

Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Current rating IEC 60092-352 Table B.4, Ampere

Short circuit

rating 1 second, Ampere

1 16 2.5 STCC 1.16 1.48 0.116 0.140 96 2240 1 25 4 STCC 0.734 0.936 0.110 0.132 127 3500 1 35 6 STCC 0.529 0.675 0.106 0.128 157 4900 1 50 6 STCC 0.391 0.499 0.104 0.125 196 7000 1 70 10 STCC 0.27 0.344 0.099 0.119 242 9800 1 95 10 STCC 0.195 0.249 0.097 0.116 293 13300 1 120 10 STCC 0.154 0.196 0.094 0.113 339 16800 1 150 10 STCC 0.126 0.161 0.092 0.111 389 21000 1 185 10 STCC 0.1 0.128 0.091 0.109 444 25900 1 240 16 STCC 0.0762 0.0972 0.089 0.107 522 33600 1 300 16 STCC 0.0607 0.0774 0.087 0.105 601 42000 2 1.5 4 STCC 12.2 15.6 0.110 0.132 20 210 3G 1.5 - STCC 12.2 15.6 0.110 0.132 20 210 4G 1.5 - STCC 12.2 15.6 0.110 0.132 16 210 3 1.5 4 STCC 12.2 15.6 0.110 0.132 16 210 4 1.5 6 STCC 12.2 15.6 0.110 0.132 16 210 5 1.5 6 STCC 12.2 15.6 0.110 0.132 13.5 210 7 1.5 6 STCC 12.2 15.6 0.110 0.132 12 210 12 1.5 10 STCC 12.2 15.6 0.110 0.132 10 210

256

Page 264: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 1kV(4).doc 03/06/2008 08:33:00

Page 7 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable

www.drakaMOG.com Subject to change without prior notice

Number of

elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type 2

Max. conductor

resistance at 20°C,

Ohm/km

Max. conductor

resistance at 90°C,

Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Current rating IEC 60092-352 Table B.4, Ampere

Short circuit

rating 1 second, Ampere

19 1.5 10 STCC 12.2 15.6 0.110 0.132 8.5 210 27 1.5 10 STCC 12.2 15.6 0.110 0.132 7.5 210 37 1.5 16 STCC 12.2 15.6 0.110 0.132 7 210 5G 1.5 - STCC 12.2 15.6 0.110 0.132 16 210 7G 1.5 - STCC 12.2 15.6 0.110 0.132 12.5 210 2 2.5 4 STCC 7.56 9.64 0.103 0.123 26 350 3G 2.5 - STCC 7.56 9.64 0.103 0.123 26 350 3 2.5 6 STCC 7.56 9.64 0.103 0.123 21 350 4G 2.5 - STCC 7.56 9.64 0.103 0.123 21 350 5G 2.5 - STCC 7.56 9.64 0.103 0.123 21 350 4 2.5 6 STCC 7.56 9.64 0.103 0.123 21 350 5 2.5 6 STCC 7.56 9.64 0.103 0.123 17.5 350 7 2.5 6 STCC 7.56 9.64 0.103 0.123 15.5 350 12 2.5 10 STCC 7.56 9.64 0.103 0.123 13 350 19 2.5 10 STCC 7.56 9.64 0.103 0.123 11 350 27 2.5 16 STCC 7.56 9.64 0.103 0.123 10 350 37 2.5 16 STCC 7.56 9.64 0.103 0.123 9 350 4G 4 - STCC 4.7 5.99 0.096 0.115 28 560 7G 2.5 - STCC 7.56 9.64 0.103 0.123 16.5 350 2 4 6 STCC 4.7 5.99 0.096 0.115 34 560 3 4 6 STCC 4.7 5.99 0.096 0.115 28 560 4 4 6 STCC 4.7 5.99 0.096 0.115 28 560 5 4 6 STCC 4.7 5.99 0.096 0.115 23.5 560 3G 4 - STCC 4.7 5.99 0.096 0.115 34 560 5G 4 - STCC 4.7 5.99 0.096 0.115 28 560 2 6 6 STCC 3.11 3.97 0.090 0.108 44 840 3 6 6 STCC 3.11 3.97 0.090 0.108 36 840 4 6 6 STCC 3.11 3.97 0.090 0.108 36 840 4G 6 - STCC 3.11 3.97 0.090 0.108 36 840 3G 6 - STCC 3.11 3.97 0.090 0.108 44 840 5G 6 - STCC 3.11 3.97 0.090 0.108 36 840 2 10 10 STCC 1.84 2.35 0.084 0.101 61 1400 3 10 10 STCC 1.84 2.35 0.084 0.101 50 1400 4 10 10 STCC 1.84 2.35 0.084 0.101 50 1400 3G 10 - STCC 1.84 2.35 0.084 0.101 61 1400 5G 10 - STCC 1.84 2.35 0.084 0.101 50 1400 4G 10 - STCC 1.84 2.35 0.084 0.101 50 1400 2 16 16 STCC 1.16 1.48 0.080 0.096 80 2240 3 16 16 STCC 1.16 1.48 0.080 0.096 67 2240 4 16 16 STCC 1.16 1.48 0.080 0.096 67 2240 4G 16 - STCC 1.16 1.48 0.080 0.096 67 2240 5G 16 - STCC 1.16 1.48 0.080 0.096 67 2240 3G 16 - STCC 1.16 1.48 0.080 0.096 80 2240 2 25 16 STCC 0.734 0.936 0.079 0.095 108 3500 3 25 16 STCC 0.734 0.936 0.079 0.095 89 3500 4 25 16 STCC 0.734 0.936 0.079 0.095 89 3500 4G 25 - STCC 0.734 0.936 0.079 0.095 89 3500 3G 25 - STCC 0.734 0.936 0.079 0.095 108 3500 5G 25 - STCC 0.734 0.936 0.079 0.095 89 3500 2 35 16 STCC 0.529 0.675 0.076 0.092 133 4900 3 35 16 STCC 0.529 0.675 0.076 0.092 110 4900 4 35 16 STCC 0.529 0.675 0.076 0.092 110 4900 4G 35 - STCC 0.529 0.675 0.076 0.092 110 4900 5G 35 - STCC 0.529 0.675 0.076 0.092 110 4900 3 50 25 STCC 0.391 0.499 0.076 0.092 137 7000 4 50 25 STCC 0.391 0.499 0.076 0.092 137 7000 4G 50 - STCC 0.391 0.499 0.076 0.092 137 7000

257

Page 265: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 1kV(4).doc 03/06/2008 08:33:00

Page 8 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable

www.drakaMOG.com Subject to change without prior notice

Number of

elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type 2

Max. conductor

resistance at 20°C,

Ohm/km

Max. conductor

resistance at 90°C,

Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Current rating IEC 60092-352 Table B.4, Ampere

Short circuit

rating 1 second, Ampere

5G 50 - STCC 0.391 0.499 0.076 0.092 137 7000 2 70 35 STCC 0.27 0.344 0.074 0.088 206 9800 3 70 35 STCC 0.27 0.344 0.074 0.088 169 9800 4 70 35 STCC 0.27 0.344 0.074 0.088 169 9800 4G 70 - STCC 0.27 0.344 0.074 0.088 169 9800 5G 70 - STCC 0.27 0.344 0.074 0.088 169 9800 5 70 35 STCC 0.27 0.344 0.074 0.088 141.5 9800 2 95 50 STCC 0.195 0.249 0.073 0.088 249 13300 3 95 50 STCC 0.195 0.249 0.073 0.088 205 13300 4 95 50 STCC 0.195 0.249 0.073 0.088 205 13300 4G 95 - STCC 0.195 0.249 0.073 0.088 205 13300 5G 120 - STCC 0.154 0.196 0.072 0.086 237 16800 2 120 60 STCC 0.154 0.196 0.072 0.086 288 16800 3 120 60 STCC 0.154 0.196 0.072 0.086 237 16800 4 120 60 STCC 0.154 0.196 0.072 0.086 237 16800 4G 120 - STCC 0.154 0.196 0.072 0.086 237 16800 4G 150 - STCC 0.126 0.161 0.072 0.087 272 21000 4G 185 - STCC 0.1 0.128 0.072 0.086 311 25900 4G 240 - STCC 0.0762 0.0972 0.080 0.095 365 33600 4 185 95 STCC 0.1 0.1275 0.081 0.098 311 25900 4 240 120 STCC 0.0762 0.0972 0.080 0.095 365 33600

Ambient temperature correction factors Ambient Temp °C 35 40 45 50 55 60 65 70 75 80

Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

258

Page 266: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 1kV(4).doc 03/06/2008 08:33:00

Page 9 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable

www.drakaMOG.com Subject to change without prior notice

Flame retardant halogen-free power cable. Mud resistant. Single core cable.

RFOU 0,6/1kV EPR/EPR/TCWB/EVA NEK 606 CodeP1/P8 Operating temperature : 90°C Operating Voltage : 0,6/1kV

Application Fixed installation for power,control and lighting in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK 606.

Standards applied IEC 60092-353/60502-1 - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame RetardantIEC 60332-3-22 - Flame RetardantIEC 60754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation R EP-rubber, IEC 60092-351 (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner covering

PET tape

Armour/screen O Tinned annealed copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "year" DRAKA 01 RFOU 0,6/1KV P1/P8 1 x 500/25 mm2 IEC 60332-3-22

Manufacturing unit DRAKA 01 = Draka Norsk Kabel, Outer sheath colour Black

259

Page 267: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 1kV(4).doc 03/06/2008 08:33:00

Page 10 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable

www.drakaMOG.com Subject to change without prior notice

Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 400 25 26.00 2.4 1.4 34.5 ± 1.5 0.4 2.1 40.5 ± 2 5060 3936

1 500 25 29.0 2.4 1.4 37.5 ± 1.5 0.4 2.2 44 ± 2 6190 4894

1 630 25 32.80 2.4 1.4 41.5 ± 2 0.4 2.3 48 ± 2 7620 6167

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

800011 RFOU 0.6/1kV 1X 400/25 P1/P8 BLACK - 7021528000115 - 800012 RFOU 0.6/1kV 1X 500/25 P1/P8 BLACK - 7021528000122 - 800013 RFOU 0.6/1kV 1X 630/25 P1/P8 BLACK - 7021528000139 -

Electrical values power cables Number

of elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type 2

Max. conductor

resistance at 20°C,

Ohm/km

Max. conductor

resistance at 90°C,

Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Current rating IEC 60092-352 Table B.4, Ampere

Short circuit

rating 1 second, Ampere

1 400 25 STCC 0.0475 0.0606 0.087 0.104 690 dc / 670 ac 56000

1 500 25 STCC 0.0369 0.0471 0.085 0.103 780 dc / 720 ac 70000

1 630 25 STCC 0.0286 0.0365 0.083 0.100 890 dc / 780 ac 88200

Ambient temperature correction factors Ambient Temp °C 35 40 45 50 55 60 65 70 75 80

Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

260

Page 268: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 1kV(4).doc 03/06/2008 08:33:00

Page 11 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable

www.drakaMOG.com Subject to change without prior notice

Flame retardant halogen-free power cable. Mud resistant. Double braided.

RFOU 0,6/1kV EPR/EPR/TCWB/EVA NEK 606 CodeP1/P8 Operating temperature : 90°C Operating Voltage : 0,6/1kV

Application Fixed installation for power,control and lighting in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK 606.

Standards applied

IEC 60092-353 - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation R EP-rubber, IEC 60092-351 (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner covering

PET tape + rubberized Polyamide tape

Armour/screen O Two layers of tinned copper wire braid (double braid) Tape over armour/screen

PET tape + rubberized Polyamide tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "year" DRAKA 01 RFOU 0,6/1kV P1/P8 3 x 185/95 mm2 IEC 60332-3-22 ETL Classified No. 3067229

Manufacturing unit DRAKA 01 = Draka Norsk Kabel, Outer sheath colour Black

261

Page 269: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 1kV(4).doc 03/06/2008 08:33:00

Page 12 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable

www.drakaMOG.com Subject to change without prior notice

Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

3 185 95 17.70 2.0 1.6 50.5 ± 2.5 0.5 2.7 59.5 ±

2.5 9220 6278

3 150 70 15.9 1.8 1.6 45.5 ± 2 0.4 2.6 54 ± 2.5 7390 4904

4 150 70 15.9 1.8 2 51.5 ± 2.5 0.4 2.8 60.5 ± 3 9320 6288

3 240 120 20.15 2.2 1.8 57.5 ± 2.5 0.6 3 68 ± 3 11820 8063

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

800093 RFOU 0.6/1kV 3X 185/95 P1/P8 BLACK - 7021528000931 - 800102 RFOU 0.6/1kV 3X 150/70 P1/P8 BLACK - 7021528001020 1044252 800109 RFOU 0.6/1kV 4X 150/70 P1/P8 BLACK - 7021528001099 - 800112 RFOU 0.6/1kV 3X 240/120 P1/P8 BLACK - 7021528001129 -

Electrical values power cables Number

of elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type 2

Max. conductor

resistance at 20°C,

Ohm/km

Max. conductor

resistance at 90°C,

Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Current rating IEC 60092-352 Table B.4, Ampere

Short circuit

rating 1 second, Ampere

3 185 95 STCC 0.1 0.128 0.072 0.086 311 25900 3 150 70 STCC 0.126 0.161 0.072 0.087 272 21000 4 150 70 STCC 0.126 0.161 0.072 0.087 272 21000 3 240 120 STCC 0.0762 0.0972 0.072 0.086 365 33600

Ambient temperature correction factors Ambient Temp °C 35 40 45 50 55 60 65 70 75 80

Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

262

Page 270: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 6_10_12kV(3).doc 29.12.2006 11:06

Page 1 of 4

FlexFlame RFOU 6/10(12) kV P3/P10 Power Cable

Flame retardant halogen-free medium voltage (MV) cable. Mud resistant

RFOU 6/10(12) kVEPR/EPR/TCWB/EVA

NEK 606 CodeP3/P10 Operating temperature : 90°CO perating Voltage : 6/10(12) kV

Application

Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas

xposed to MUD and drilling/cleaning fluids. e

Standards applied

IEC 60092-354 - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

www.drakaMOG.com Subject to change without prior notice

Code Letter

Conductor Tinned stranded and compressed copper (STCC), IEC 60228 class 2 Conductor screen semiconductive

Semiconductive layer (EP-rubber)

Insulation R EP-rubber, IEC 60092-351 (EPR) Insulation screen semicoductive

Semiconductive layer (EP-rubber)

Lay up / Shielding Cores are laid up together. Cores are identified by White, Black or Red threads under and over the metallic screen on each conductor.

Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner covering PET tape Armour/screen O Tinned annealed copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "year" DRAKA NORSK KABEL RFOU 6/10(12)KV P3/P10 3 x 95/50 mm2 IEC 60332-3-22

Outer sheath colour Red

263

Page 271: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 6_10_12kV(3).doc 29.12.2006 11:06

Page 2 of 4

FlexFlame RFOU 6/10(12) kV P3/P10 Power Cable

Range and dimensions

Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 16 11 5.2 3.4 1.0 18.5 ±1.0 0.3 1.6 24.0 ± 1,5 900 420

1 25 11 6.5 3.4 1.0 20,0 ±1.0 0.3 1.7 25.0 ± 1,5 1100 516

1 35 11 7.4 3.4 1.0 21.0 ± 1.5 0.3 1.7 26.0± 1.5 1200 611

1 50 11 8.8 3.4 1.0 22.0 ± 1.0 0.3 1.9 28.0 ±

1.5 1450 780

1 70 16 10.3 3.4 1.0 23.5 ±1.5 0.3 1.9 30.0 ± 2.0 1700 971

1 95 16 12.1 3.4 1.2 25.5 ±1.5 0.3 2.0 32.0 ± 2.0 2100 1251

1 120 20 13.6 3.4 1.2 27.5 ± 1.5 0.3 2.0 34.0 ±

2.0 2350 1506

1 150 19 15.1 3.4 1.2 28.5 ±1.5 0.3 2.0 35.0 ± 2.0 2600 1793

1 185 18 16.8 3.4 1.2 30.5 ±1.5 0.3 2.1 36.5 ± 2.0 3100 2138

1 240 21 19.1 3.4 1.2 33.0 ± 1.5 0.3 2.1 39.0± 2.0 3800 2702

1 300 29 21.5 3.4 1.2 35 ±1.5 0.3 2.2 41.5 ± 2.5 4600 3395

1 400 35 24.5 3.4 1.2 36 ±1.5 0.4 2.3 45.5 ± 2.5 5900 4536

1 500 40 27.5 3.4 1.4 41.5 ± 2.0 0.4 2.5 49.5 ±

2.5 7350 5782

1 630 40 32.3 3.4 1.4 46.5 ± 2.0 0.4 2.7 54.5 ±

3.0 8750 7016

3 16 32 5.2 3.4 1.4 39.0 ± 1.5 0.4 2.4 46.0 ±

2.5 3300 1145

3 25 31 6.5 3.4 1.4 42.0 ± 1.5 0.4 2.4 49.5 ±

2.5 3800 1465

3 35 35 7.4 3.4 1.4 43.5 ± 2.0 0.4 2.5 51.5± 3.0 4300 1573

3 50 31 8.8 3.4 1.6 47.0 ± 2.0 0.4 2.8 55 ± 3 5000 2124

3 70 35 10.3 3.4 1.6 50.0 ± 2.0 0.4 2.8 58.5 ± 3 6000 2880

3 95 50 12.1 3.4 1.6 54.0 ± 2.0 0.4 2.8 62.5± 3.0 7500 3975

3 120 60 13.6 3.4 1.6 57.5 ± 2.0 0.5 3 66.5 ±

3.0 8350 4650

3 150 75 15.1 3.4 1.6 60 ± 2 0.6 3.2 70.5 ± 3 9800 5634

3 185 45 16.8 3.4 1.6 64.5 ± 2.5 0.5 3.3 74.0 ±

3.5 11300 6511

3 240 53 19.1 3.4 1.6 69.5 ± 2.5 0.5 3.5 79.5± 3.5 13300 8609

3 300 55 21.5 3.4 1.6 74.5 ± 3.0 0.5 3.7 85.0± 4.0 16300 10725

www.drakaMOG.com Subject to change without prior notice

264

Page 272: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 6_10_12kV(3).doc 29.12.2006 11:06

Page 3 of 4

FlexFlame RFOU 6/10(12) kV P3/P10 Power Cable

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

804000 RFOU 6/10KV 1X 16/11mm² P3/P RED - 7021528040005 - 804001 RFOU 6/10KV 1X 25/11mm² P3/P RED - 7021528040012 - 804002 RFOU 6/10KV 1X 35/11mm² P3/P RED - 7021528040029 - 804003 RFOU 6/10KV 1X 50/11mm² P3/P RED - 7021528040036 - 804004 RFOU 6/10KV 1X 70/16mm² P3/P RED - 7021528040043 - 804005 RFOU 6/10KV 1X 95/16mm² P3/P RED - 7021528040050 - 804006 RFOU 6/10KV 1X 120/20mm² P3/ RED - 7021528040067 - 804007 RFOU 6/10KV 1X 150/19mm² P3/ RED - 7021528040074 - 804008 RFOU 6/10KV 1X185/18mm² P3/P10 RED - 7021528040081 - 804009 RFOU 6/10KV 1X 240/21mm² P3/ RED - 7021528040098 - 804010 RFOU 6/10KV 1X 300/29mm² P3/ RED - 7021528040104 - 804011 RFOU 6/10KV 1X 400/35mm² P3/ RED - 7021528040111 - 804012 RFOU 6/10KV 1X 500/40mm² P3/ RED - 7021528040128 - 804013 RFOU 6/10KV 1X 630/40mm² P3/ RED - 7021528040135 - 804020 RFOU 6/10KV 3X 16/32mm² P3/P RED - 7021528040203 - 804021 RFOU 6/10KV 3X 25/31mm² P3/P RED - 7021528040210 - 804022 RFOU 6/10KV 3X 35/35mm² P3/P RED - 7021528040227 - 804023 RFOU 6/10KV 3X 50/31mm² P3/P RED - 7021528040234 - 804024 RFOU 6/10KV 3X 70/35mm² P3/P RED - 7021528040241 - 804025 RFOU 6/10KV 3X 95/50mm² P3/P RED - 7021528040258 - 804026 RFOU 6/10KV 3X 120/60mm² P3/ RED - 7021528040265 - 804027 RFOU 6/10KV 3X 150/75mm² P3/ RED - 7021528040272 - 804028 RFOU 6/10KV 3X 185/45mm² P3/ RED - 7021528040289 - 804029 RFOU 6/10KV 3X 240/53mm² P3/ RED - 7021528040296 - 804030 RFOU 6/10KV 3X 300/55mm² P3/ RED - 7021528040302 -

Electrical values power cables

www.drakaMOG.com Subject to change without prior notice

Number of

elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type 2

Max. conductor resistance at 20°C, Ohm/km

Max. conductor resistance at 90°C, Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Capacitans per phase,

nF/km

Current rating IEC

60092-352

Table B.4,

Ampere

Short circuit

rating 1 second, Ampere

1 16 11 STCC 1.16 1.48 0.154 0.185 220 96 2240 1 25 11 STCC 0.734 0.936 0.144 0.173 250 127 3500 1 35 11 STCC 0.529 0.675 0.138 0.166 270 157 4900 1 50 11 STCC 0.391 0.499 0.132 0.158 300 196 7000 1 70 16 STCC 0.270 0.344 0.125 0.150 340 242 9800 1 95 16 STCC 0.195 0.249 0.119 0.142 380 293 13300 1 120 20 STCC 0.154 0.196 0.116 0.139 410 339 16800 1 150 19 STCC 0.126 0.161 0.111 0.133 450 389 21000 1 185 18 STCC 0.100 0.128 0.108 0.130 480 444 25900 1 240 21 STCC 0.0762 0.0972 0.104 0.125 540 522 33600 1 300 29 STCC 0.0607 0.0774 0.104 0.124 590 601 42000

1 400 35 STCC 0.0475 0.0606 0.090 0.118 660 690 dc / 670 ac 56000

1 500 40 STCC 0.0369 0.0471 0.097 0.117 720 780 dc / 720 ac 70000

1 630 40 STCC 0.0286 0.0365 0.092 0.110 840 890 dc / 780 ac 88200

265

Page 273: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU 6_10_12kV(3).doc 29.12.2006 11:06

Page 4 of 4

FlexFlame RFOU 6/10(12) kV P3/P10 Power Cable

www.drakaMOG.com Subject to change without prior notice

Number of

elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type 2

Max. conductor resistance at 20°C, Ohm/km

Max. conductor resistance at 90°C, Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Capacitans per phase,

nF/km

Current rating IEC

60092-352

Table B.4,

Ampere

Short circuit

rating 1 second, Ampere

3 16 32 STCC 1.16 1.48 0.119 0.143 220 67 2240 3 25 31 STCC 0.734 0.936 0.119 0.143 250 89 3500 3 35 35 STCC 0.529 0.675 0.114 0.137 270 110 4900 3 50 31 STCC 0.391 0.499 0.108 0.130 300 137 7000 3 70 35 STCC 0.270 0.344 0.103 0.124 340 169 9800 3 95 50 STCC 0.195 0.249 0.098 0.118 380 205 13300 3 120 60 STCC 0.154 0.196 0.095 0.114 410 237 16800 3 150 75 STCC 0.126 0.161 0.092 0.111 450 272 21000 3 185 45 STCC 0.100 0.128 0.092 0.111 480 311 25900 3 240 53 STCC 0.0762 0.0972 0.087 0.104 540 365 33600 3 300 55 STCC 0.0607 0.0774 0.084 0.101 590 421 42000

Ambient temperature correction factors Ambient Temp °C 35 40 45 50 55 60 65 70 75 80 Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47 Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 15 x D 9 x D 50 N /mm² -20°C

266

Page 274: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU(C) 250V(3).doc 03/06/2008 15:29:00

Page 1 of 4

FlexFlame RFOU(c) 250V S2/S6 Instr. cable

Flame retardant halogen-free instrumentation cable. Mud resistant

RFOU(c) 250V

EPR/EPR/TCWB/EVA NEK 606 CodeS2/S6 Operating temperature : 90°CO perating Voltage : 250V

Application Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas. Meets the mud esistant requirements in NEK 606. r

Standards applied

IEC 60092-376 (2003-05) - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation R EP-rubber, IEC 60092-351 (EPR)

Pair / Triple / Quad twisting

Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs/triples are identified by numbers printed directly on the insulated conductors.

Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner covering

PET tape

Armour/screen O Tinned annealed copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "year" DRAKA 01 RFOU(c) 250V S2/S6 8 PAIR 0,75 mm2 IEC 60092-376 IEC 60332-3-22 ETL Classified No. 3067229

Manufacturing unit

DRAKA 01 = Draka Norsk Kabel,

Outer sheath colour

Grey or Blue

www.drakaMOG.com Subject to change without prior notice

267

Page 275: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU(C) 250V(3).doc 03/06/2008 15:29:00

Page 2 of 4

FlexFlame RFOU(c) 250V S2/S6 Instr. cable

Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey

Range and dimensions

Number of elements

No of cores in element

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

2 2 0.75 1.1 0.6 1.1 10 ± 0.8 0.2 1.2 13 ± 0.8 275 82 2 2 0.75 1.1 0.6 1.1 10 ± 0.8 0.2 1.2 13 ± 0.8 275 82

4 2 0.75 1.1 0.6 1.1 11.5 ± 0.8 0.3 1.3 15 ± 0.8 390 139

4 2 0.75 1.1 0.6 1.1 11.5 ± 0.8 0.3 1.3 15 ± 0.8 390 139

8 2 0.75 1.1 0.6 1.1 15 ± 0.8 0.3 1.4 19 ± 0.8 600 223 8 2 0.75 1.1 0.6 1.1 15 ± 0.8 0.3 1.4 19 ± 0.8 600 223 12 2 0.75 1.1 0.6 1.3 18 ± 0.8 0.3 1.5 22 ± 1 790 291 12 2 0.75 1.1 0.6 1.3 18 ± 0.8 0.3 1.5 22 ± 1 790 291

16 2 0.75 1.1 0.6 1.4 19.5 ± 0.8 0.3 1.6 23.5 ± 1 950 359

16 2 0.75 1.1 0.6 1.4 19.5 ± 0.8 0.3 1.6 23.5 ± 1 950 359

19 2 0.75 1.1 0.6 1.4 20.5 ± 1 0.3 1.7 25 ± 1 1090 422 24 2 0.75 1.1 0.6 1.6 24 ± 1 0.3 1.8 28.5 ± 1 1350 511 24 2 0.75 1.1 0.6 1.6 24 ± 1 0.3 1.8 28.5 ± 1 1350 511

2 3 0.75 1.1 0.6 1.1 11 ± 0.8 0.3 1.3 14.5 ± 0.8 360 127

2 3 0.75 1.1 0.6 1.1 11 ± 0.8 0.3 1.3 14.5 ± 0.8 360 127

4 3 0.75 1.1 0.6 1.1 12.5 ± 0.8 0.3 1.3 16.5 ±

0.8 470 182

4 3 0.75 1.1 0.6 1.1 12.5 ± 0.8 0.3 1.3 16.5 ±

0.8 470 182

8 3 0.75 1.1 0.6 1.1 17 ± 0.8 0.3 1.5 21 ± 1 760 292 8 3 0.75 1.1 0.6 1.1 17 ± 0.8 0.3 1.5 21 ± 1 740 292 12 3 0.75 1.1 0.6 1.3 20 ± 1 0.3 1.6 24 ± 1 990 386 12 3 0.75 1.1 0.6 1.3 20 ± 1 0.3 1.6 24 ± 1 990 386 16 3 0.75 1.1 0.6 1.4 21.5 ± 1 0.3 1.7 26 ± 1 1220 488 24 3 0.75 1.1 0.6 1.8 27 ± 1 0.3 2 32 ± 1.5 1790 692 24 3 0.75 1.1 0.6 1.8 27 ± 1 0.3 2 32 ± 1.5 1790 692

2 2 1.5 1.6 0.7 1.1 12 ± 0.8 0.3 1.3 15.5 ± 0.8 410 162

2 2 1.5 1.6 0.7 1.1 12 ± 0.8 0.3 1.3 15.5 ± 0.8 410 162

4 2 1.5 1.6 0.7 1.1 14 ± 0.8 0.3 1.4 18 ± 0.8 560 235 4 2 1.5 1.6 0.7 1.1 14 ± 0.8 0.3 1.4 18 ± 0.8 560 235 5 2 1.5 1.6 0.7 1.1 15 ± 0.8 0.3 1.4 19 ± 0.8 640 263

8 2 1.5 1.6 0.7 1.1 18.5 ± 0.8 0.3 1.6 23 ± 1 890 379

8 2 1.5 1.6 0.7 1.1 18.5 ± 0.8 0.3 1.6 23 ± 1 890 379

10 2 1.5 1.6 0.7 1.2 21 ± 1 0.3 1.7 25.5 ± 1 1070 460 10 2 1.5 1.6 0.7 1.2 21 ± 1 0.3 1.7 25.5 ± 1 1070 460 12 2 1.5 1.6 0.7 1.3 22 ± 1 0.3 1.7 26.5 ± 1 1190 515 16 2 1.5 1.6 0.7 1.4 24 ± 1 0.3 1.8 28.5 ± 1 1480 652 16 2 1.5 1.6 0.7 1.4 24 ± 1 0.3 1.8 28.5 ± 1 1480 652 19 2 1.5 1.6 0.7 1.4 25.5 ± 1 0.3 1.9 30 ± 1.5 1640 736

24 2 1.5 1.6 0.7 1.8 30 ± 1.5 0.3 2.1 35.5 ± 1.5 2150 925

www.drakaMOG.com Subject to change without prior notice

268

Page 276: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU(C) 250V(3).doc 03/06/2008 15:29:00

Page 3 of 4

FlexFlame RFOU(c) 250V S2/S6 Instr. cable

www.drakaMOG.com Subject to change without prior notice

Number of elements

No of cores in element

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight Copper of Cable content Approx. Approx. (Kg/Km) (kg/km)

32 2 1.5 1.6 0.7 1.9 33 ± 1.5 0.4 2.2 39 ± 1.5 2760 1253 32 2 1.5 1.6 0.7 1.9 33 ± 1.5 0.4 2.2 39 ± 1.5 2760 1253 2 3 1.5 1.6 0.7 1.1 13 ± 0.8 0.3 1.4 17 ± 0.8 490 191

4 3 1.5 1.6 0.7 1.1 15.5 ± 0.8 0.3 1.4 19.5 ±

0.8 670 291

8 3 1.5 1.6 0.7 1.1 21 ± 1 0.3 1.7 25.5 ± 1 1130 517 12 3 1.5 1.6 0.7 1.3 24.5 ± 1 0.3 1.8 29 ± 1 1550 711 12 3 1.5 1.6 0.7 1.3 24.5 ± 1 0.3 1.8 29 ± 1 1550 711

16 3 1.5 1.6 0.7 1.4 26.5 ± 1 0.3 1.9 31.5 ± 1.5 1930 904

16 3 1.5 1.6 0.7 1.4 26.5 ± 1 0.3 1.9 31.5 ± 1.5 1930 904

24 3 1.5 1.6 0.7 1.8 33.5 ± 1.5 0.4 2.2 39.5 ±

1.5 2920 1370

24 3 1.5 1.6 0.7 1.8 33.5 ± 1.5 0.4 2.2 39.5 ±

1.5 2920 1370

2 2 2.5 2 0.7 1.1 13.5 ± 0.8 0.3 1.4 17.5 ±

0.8 490 200

4 2 2.5 2 0.7 1.1 16 ± 0.8 0.3 1.4 19.5 ± 0.8 680 309

4 2 2.5 2 0.7 1.1 16 ± 0.8 0.3 1.4 19.5 ± 0.8 680 309

5 2 2.5 2 0.7 1.1 17.5 ± 0.8 0.3 1.5 21.5 ± 1 820 371

12 2 2.5 2 0.7 1.3 25 ± 1 0.3 1.8 30 ± 1.5 1560 758

Electrical values instrumentation cables

Type Capacitance, approx. (nF/km)

Inductance, approx, (mH/km)

Resistance at 20°C, max. (Ohm/km)

L/R ratio, (microH/Ohm)

Unshielded pair 0,75 mm² 100 0,67 26,3 12,7 Unshielded triple 0,75 mm² 100 0,67 26,3 12,7 Unshielded pair 1,5 mm² 110 0,63 12,2 26,6 Unshielded triple 1,5 mm² 110 0,63 12,2 26,6 Unshielded pair 2,5 mm² 125 0,59 7,56 39,0 Unshielded triple 2,5 mm² 125 0,59 7,56 39,0

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

892606 RFOU(C) 2PAIR 0.75mm² S2/S6 GREY Yes 7021528926064 1044421 892607 RFOU(C) 2PAIR 0.75mm² S2/S6 BLUE Yes 7021528926071 1044422 892618 RFOU(C) 4PAIR 0.75mm² S2/S6 GREY Yes 7021528926187 1044423 892619 RFOU(C) 4PAIR 0.75mm² S2/S6 BLUE Yes 7021528926194 1044424 892630 RFOU(C) 8PAIR 0.75mm² S2/S6 GREY Yes 7021528926309 1044428 892631 RFOU(C) 8PAIR 0.75mm² S2/S6 BLUE Yes 7021528926316 1044429 892636 RFOU(C) 12PAIR 0.75mm² S2/S6 GREY Yes 7021528926361 1044430 892637 RFOU(C) 12PAIR 0.75mm² S2/S6 BLUE - 7021528926378 1044431 892642 RFOU(C) 16PAIR 0.75mm² S2/S6 GREY Yes 7021528926422 1044433 892643 RFOU(C) 16PAIR 0.75mm² S2/S6 BLUE Yes 7021528926439 1044432 892645 RFOU(C) 19PAIR 0.75mm² S2/S6 GREY - 7021528926453 1044434 892648 RFOU(C) 24PAIR 0.75mm² S2/S6 GREY Yes 7021528926484 1044438 892649 RFOU(C) 24PAIR 0.75mm² S2/S6 BLUE Yes 7021528926491 1044437

269

Page 277: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU(C) 250V(3).doc 03/06/2008 15:29:00

Page 4 of 4

FlexFlame RFOU(c) 250V S2/S6 Instr. cable

www.drakaMOG.com Subject to change without prior notice

Part number Description Sheath Colour Stock item EAN No. DNK EL No. 892666 RFOU(C) 2TRIP 0.75mm² S2/S6 GREY Yes 7021528926668 1044490 892667 RFOU(C) 2TRIP 0.75mm² S2/S6 BLUE Yes 7021528926675 1044491 892678 RFOU(C) 4TRIP 0.75mm² S2/S6 GREY - 7021528926781 1044492 892679 RFOU(C) 4TRIP 0.75mm² S2/S6 BLUE - 7021528926798 1044493 892690 RFOU(C) 8TRIP 0.75mm² S2/S6 GREY - 7021528926903 1044496 892691 RFOU(C) 8TRIP 0.75mm² S2/S6 BLUE - 7021528926910 1044497 892696 RFOU(C) 12TRIP 0.75mm² S2/S6 GREY - 7021528926965 1044499 892697 RFOU(C) 12TRIP 0.75mm² S2/S6 BLUE - 7021528926972 1044500 892702 RFOU(C) 16TRIP 0.75mm² S2/S6 GREY - 7021528927023 1044501 892708 RFOU(C) 24TRIP 0.75mm² S2/S6 GREY - 7021528927085 1044507 892709 RFOU(C) 24TRIP 0.75mm² S2/S6 BLUE - 7021528927092 1044508 892806 RFOU(C) 2PAIR 1.5mm² S2/S6 GREY Yes 7021528928068 1044461 892807 RFOU(C) 2PAIR 1.5mm² S2/S6 BLUE - 7021528928075 1044462 892818 RFOU(C) 4PAIR 1.5mm² S2/S6 GREY Yes 7021528928181 1044463 892819 RFOU(C) 4PAIR 1.5mm² S2/S6 BLUE - 7021528928198 1044464 892821 RFOU(C) 5PAIR 1.5mm² S2/S6 GREY - 7021528928211 - 892830 RFOU(C) 8PAIR 1.5mm² S2/S6 GREY Yes 7021528928303 1044468 892831 RFOU(C) 8PAIR 1.5mm² S2/S6 BLUE - 7021528928310 1044469 892834 RFOU(C) 10PAIR 1.5mm² S2/S6 GREY - 7021528928341 - 892835 RFOU(C) 10PAIR 1.5mm² S2/S6 BLUE - 7021528928358 - 892836 RFOU(C) 12PAIR 1.5mm² S2/S6 GREY - 7021528928365 1044470 892842 RFOU(C) 16PAIR 1.5mm² S2/S6 GREY Yes 7021528928426 1044472 892843 RFOU(C) 16PAIR 1.5mm² S2/S6 BLUE - 7021528928433 1044473 892845 RFOU(C) 19PAIR 1.5mm² S2/S6 GREY Yes 7021528928457 1044474 892848 RFOU(C) 24PAIR 1.5mm² S2/S6 GREY - 7021528928488 1044478 892854 RFOU(C) 32PAIR 1.5mm² S2/S6 GREY - 7021528928549 - 892855 RFOU(C) 32PAIR 1.5mm² S2/S6 BLUE - 7021528928556 - 892866 RFOU(C) 2TRIP 1.5mm² S2/S6 GREY - 7021528928662 1044561 892878 RFOU(C) 4TRIP 1.5mm² S2/S6 GREY - 7021528928785 1044563 892891 RFOU(C) 8TRIP 1.5mm² S2/S6 BLUE - 7021528928914 1044568 892896 RFOU(C) 12TRIP 1.5mm² S2/S6 GREY - 7021528928969 1044569 892897 RFOU(C) 12TRIP 1.5mm² S2/S6 BLUE - 7021528928976 1044570 892902 RFOU(C) 16TRIP 1.5mm² S2/S6 GREY - 7021528929027 1044571 892903 RFOU(C) 16TRIP 1.5mm² S2/S6 BLUE - 7021528929034 1044572 892908 RFOU(C) 24TRIP 1.5mm² S2/S6 GREY - 7021528929089 1044577 892909 RFOU(C) 24TRIP 1.5mm² S2/S6 BLUE - 7021528929096 1044578 893006 RFOU(C) 2PAIR 2.5mm² S2/S6 GREY - 7021528930061 - 893018 RFOU(C) 4PAIR 2.5mm² S2/S6 GREY - 7021528930184 - 893019 RFOU(C) 4PAIR 2.5mm² S2/S6 BLUE - 7021528930191 - 893021 RFOU(C) 5PAIR 2.5mm² S2/S6 GREY - 7021528930214 - 893036 RFOU(C) 12PAIR 2.5mm² S2/S6 GREY - 7021528930368 -

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

270

Page 278: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU(I) 250V(3).doc 03/06/2008 10:46:00

Page 1 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable

Flame retardant halogen-free instrumentation cable. Mud resistant

RFOU(i) 250V

EPR/EPR/TCWB/EVA NEK 606 CodeS1/S5 Operating temperature : 90°C O perating Voltage : 250V

Application Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas. Meets the mud esistant requirements in NEK 606. r

Standards applied

IEC 60092-376 (2003-05) - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame RetardantIEC 60332-3-22 - Flame RetardantIEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation R EP-rubber, IEC 60092-351 (EPR)

Pair / Triple / Quad twisting

Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbers printed directly on the insulated conductors.

Lay up / Shielding

Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape.

Inner covering F Flame retardant and halogen-free thermoset compound Tape over inner covering

PET tape

Armour/screen O Tinned annealed copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "year" DRAKA 01 RFOU(i) 250V S1/S5 4 PAIR 0,75 mm2 IEC 60092-376 IEC 60332-3-22 ETL Classified No. 3067229

Manufacturing unit

DRAKA 01 = Draka Norsk Kabel,

Outer sheath colour

Grey or Blue

www.drakaMOG.com

Subject to change without prior notice

271

Page 279: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU(I) 250V(3).doc 03/06/2008 10:46:00

Page 2 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable

Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey

Range and dimensions

www.drakaMOG.com Subject to change without prior notice

Number of elements

No of cores in element

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 2 0.75 1.1 0.6 1.1 7 ± 0.5 0.2 1.1 10 ± 0.8 185 55 1 2 0.75 1.1 0.6 1.1 7 ± 0.5 0.2 1.1 10 ± 0.8 185 55 2 2 0.75 1.1 0.6 1.1 10 ± 0.8 0.2 1.2 13 ± 0.8 280 87 2 2 0.75 1.1 0.6 1.1 10 ± 0.8 0.2 1.2 13 ± 0.8 280 87

4 2 0.75 1.1 0.6 1.1 11.5 ± 0.8 0.3 1.3 15 ± 0.8 430 169

4 2 0.75 1.1 0.6 1.1 11.5 ± 0.8 0.3 1.3 15 ± 0.8 430 169

8 2 0.75 1.1 0.6 1.1 15.5 ± 0.8 0.3 1.5 19.5 ±

0.8 690 271

8 2 0.75 1.1 0.6 1.1 15.5 ± 0.8 0.3 1.5 19.5 ±

0.8 690 271

12 2 0.75 1.1 0.6 1.3 18.5 ± 0.8 0.3 1.6 22.5 ± 1 930 356

12 2 0.75 1.1 0.6 1.3 18.5 ± 0.8 0.3 1.6 22.5 ± 1 930 356

16 2 0.75 1.1 0.6 1.4 20.5 ± 1 0.3 1.7 25 ± 1 1160 449 16 2 0.75 1.1 0.6 1.4 20.5 ± 1 0.3 1.7 25 ± 1 1160 449 19 2 0.75 1.1 0.6 1.4 21.5 ± 1 0.3 1.7 26 ± 1 1280 501 19 2 0.75 1.1 0.6 1.4 21.5 ± 1 0.3 1.7 26 ± 1 1280 501

24 2 0.75 1.1 0.6 1.6 25.5 ± 1 0.3 1.9 30.5 ± 1.5 1630 612

24 2 0.75 1.1 0.6 1.6 25.5 ± 1 0.3 1.9 30.5 ± 1.5 1630 612

1 3 0.75 1.1 0.6 1.1 7 ± 0.5 0.2 1.1 10.5 ± 0.8 200 61

1 3 0.75 1.1 0.6 1.1 7 ± 0.5 0.2 1.1 10.5 ± 0.8 200 61

2 3 0.75 1.1 0.6 1.1 11 ± 0.8 0.3 1.3 14.5 ± 0.8 380 148

2 3 0.75 1.1 0.6 1.1 11 ± 0.8 0.3 1.3 14.5 ± 0.8 380 148

4 3 0.75 1.1 0.6 1.1 12.5 ± 0.8 0.3 1.4 16.5 ±

0.8 530 211

4 3 0.75 1.1 0.6 1.1 12.5 ± 0.8 0.3 1.4 16.5 ±

0.8 530 211

8 3 0.75 1.1 0.6 1.1 17 ± 0.8 0.3 1.6 21.5 ± 1 840 339 8 3 0.75 1.1 0.6 1.1 17 ± 0.8 0.3 1.6 21.5 ± 1 840 339 12 3 0.75 1.1 0.6 1.3 20.5 ± 1 0.3 1.7 25 ± 1 1150 459 12 3 0.75 1.1 0.6 1.3 20.5 ± 1 0.3 1.7 25 ± 1 1150 459 16 3 0.75 1.1 0.6 1.4 23 ± 1 0.3 1.8 28 ± 1 1440 579 16 3 0.75 1.1 0.6 1.4 23 ± 1 0.3 1.8 28 ± 1 1440 579 19 3 0.75 1.1 0.6 1.4 24 ± 1 0.3 1.8 29 ± 1 1600 650

24 3 0.75 1.1 0.6 1.8 29 ± 1 0.3 2 34.5 ± 1.5 2110 818

24 3 0.75 1.1 0.6 1.8 29 ± 1 0.3 2 34.5 ± 1.5 2110 818

1 2 1.5 1.6 0.7 1.1 8 ± 0.5 0.2 1.1 11 ± 0.8 230 72 1 2 1.5 1.6 0.7 1.1 8 ± 0.5 0.2 1.1 11 ± 0.8 230 72

2 2 1.5 1.6 0.7 1.1 12 ± 0.8 0.3 1.3 15.5 ± 0.8 420 169

272

Page 280: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU(I) 250V(3).doc 03/06/2008 10:46:00

Page 3 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable

www.drakaMOG.com Subject to change without prior notice

Number of elements

No of cores in element

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Inner covering, mm

Diameter inner covering, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight Copper of Cable content Approx. Approx. (Kg/Km) (kg/km)

2 2 1.5 1.6 0.7 1.1 12 ± 0.8 0.3 1.3 15.5 ± 0.8 420 169

4 2 1.5 1.6 0.7 1.1 14 ± 0.8 0.3 1.4 18 ± 0.8 600 254 4 2 1.5 1.6 0.7 1.1 14 ± 0.8 0.3 1.4 18 ± 0.8 600 254 8 2 1.5 1.6 0.7 1.1 19 ± 0.8 0.3 1.6 23.5 ± 1 990 425 8 2 1.5 1.6 0.7 1.1 19 ± 0.8 0.3 1.6 23.5 ± 1 990 425 12 2 1.5 1.6 0.7 1.3 23 ± 1 0.3 1.8 27.5 ± 1 1370 588 12 2 1.5 1.6 0.7 1.3 23 ± 1 0.3 1.8 27.5 ± 1 1370 588

16 2 1.5 1.6 0.7 1.4 25.5 ± 1 0.3 1.9 30.5 ± 1.5 1730 750

16 2 1.5 1.6 0.7 1.4 25.5 ± 1 0.3 1.9 30.5 ± 1.5 1730 750

19 2 1.5 1.6 0.7 1.4 26.5 ± 1 0.3 1.9 31.5 ± 1.5 1940 878

19 2 1.5 1.6 0.7 1.4 26.5 ± 1 0.3 1.9 31.5 ± 1.5 1940 878

24 2 1.5 1.6 0.7 1.8 32 ± 1.5 0.4 2.2 38 ± 1.5 2670 1180 24 2 1.5 1.6 0.7 1.8 32 ± 1.5 0.4 2.2 38 ± 1.5 2670 1180

32 2 1.5 1.6 0.7 1.9 35.5 ± 1.5 0.4 2.3 42 ± 2 3320 1500

32 2 1.5 1.6 0.7 1.9 35.5 ± 1.5 0.4 2.3 42 ± 2 3320 1500

1 3 1.5 1.6 0.7 1.1 8.5 ± 0.5 0.2 1.1 11.5 ± 0.8 265 93

1 3 1.5 1.6 0.7 1.1 8.5 ± 0.5 0.2 1.1 11.5 ± 0.8 265 93

2 3 1.5 1.6 0.7 1.1 13.5 ± 0.8 0.3 1.4 17.5 ±

0.8 520 214

4 3 1.5 1.6 0.7 1.1 15.5 ± 0.8 0.3 1.5 20 ± 1 740 328

4 3 1.5 1.6 0.7 1.1 15.5 ± 0.8 0.3 1.5 20 ± 1 740 328

8 3 1.5 1.6 0.7 1.1 21.5 ± 1 0.3 1.7 26 ± 1 1240 563 8 3 1.5 1.6 0.7 1.1 21.5 ± 1 0.3 1.7 26 ± 1 1240 563

12 3 1.5 1.6 0.7 1.3 26 ± 1 0.3 1.9 30.5 ± 1.5 1730 783

12 3 1.5 1.6 0.7 1.3 26 ± 1 0.3 1.9 30.5 ± 1.5 1730 783

16 3 1.5 1.6 0.7 1.6 29.5 ± 1 0.3 2 34.5 ± 1.5 2260 1002

16 3 1.5 1.6 0.7 1.6 29.5 ± 1 0.3 2 34.5 ± 1.5 2260 1002

24 3 1.5 1.6 0.7 1.8 36.5 ± 1.5 0.4 2.3 42.5 ± 2 3380 1566

24 3 1.5 1.6 0.7 1.8 36.5 ± 1.5 0.4 2.3 42.5 ± 2 3380 1566

1 2 2.5 2 0.7 1.1 9 ± 0.5 0.2 1.1 12 ± 0.8 280 99

2 2 2.5 2 0.7 1.1 13.5 ± 0.8 0.3 1.4 17.5 ±

0.8 530 225

4 2 2.5 2 0.7 1.1 16 ± 0.8 0.3 1.5 20 ± 1 770 350

273

Page 281: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU(I) 250V(3).doc 03/06/2008 10:46:00

Page 4 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable

Electrical values instrumentation cables Type Capacitance,

approx. (nF/km) Inductance,

approx, (mH/km)Resistance at 20°C,

max. (Ohm/km) L/R ratio,

(microH/Ohm) Shielded pair 0,75 mm² 110 0,67 26,3 12,7 Shielded triple 0,75 mm² 110 0,67 26,3 12,7 Shielded pair 1,5 mm² 125 0,63 12,2 26,6 Shielded triple 1,5 mm² 125 0,63 12,2 26,6 Shielded pair 2,5 mm² 145 0,59 7,56 39,0 Shielded triple 2,5 mm² 145 0,59 7,56 39,0

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

892000 RFOU(I) 1PAIR 0.75mm² S1/S5 GREY Yes 7021528920000 1044620 892001 RFOU(I) 1PAIR 0.75mm² S1/S5 BLUE Yes 7021528920017 1044619 892006 RFOU(I) 2PAIR 0.75mm² S1/S5 GREY Yes 7021528920062 1044621 892007 RFOU(I) 2PAIR 0.75mm² S1/S5 BLUE - 7021528920079 1044622 892018 RFOU(I) 4PAIR 0.75mm² S1/S5 GREY Yes 7021528920185 1044623 892019 RFOU(I) 4PAIR 0.75mm² S1/S5 BLUE - 7021528920192 1044624 892030 RFOU(I) 8PAIR 0.75mm² S1/S5 GREY Yes 7021528920307 1044628 892031 RFOU(I) 8PAIR 0.75mm² S1/S5 BLUE - 7021528920314 1044629 892036 RFOU(I) 12PAIR 0.75mm² S1/S5 GREY - 7021528920369 1044630 892037 RFOU(I) 12PAIR 0.75mm² S1/S5 BLUE - 7021528920376 1044631 892042 RFOU(I) 16PAIR 0.75mm² S1/S5 GREY - 7021528920420 1044633 892043 RFOU(I) 16PAIR 0.75mm² S1/S5 BLUE - 7021528920437 1044632 892045 RFOU(I) 19PAIR 0.75mm² S1/S5 GREY - 7021528920451 1044634 892046 RFOU(I) 19PAIR 0.75mm² S1/S5 BLUE - 7021528920468 1044635 892048 RFOU(I) 24PAIR 0.75mm² S1/S5 GREY - 7021528920482 1044636 892049 RFOU(I) 24PAIR 0.75mm² S1/S5 BLUE - 7021528920499 1044637 892060 RFOU(I) 1TRIP 0.75mm² S1/S5 GREY Yes 7021528920604 1044690 892061 RFOU(I) 1TRIP 0.75mm² S1/S5 BLUE Yes 7021528920611 1044689 892066 RFOU(I) 2TRIP 0.75mm² S1/S5 GREY - 7021528920666 1044691 892067 RFOU(I) 2TRIP 0.75mm² S1/S5 BLUE - 7021528920673 1044692 892078 RFOU(I) 4TRIP 0.75mm² S1/S5 GREY - 7021528920789 1044693 892079 RFOU(I) 4TRIP 0.75mm² S1/S5 BLUE - 7021528920796 1044694 892090 RFOU(I) 8TRIP 0.75mm² S1/S5 GREY - 7021528920901 1044697 892091 RFOU(I) 8TRIP 0.75mm² S1/S5 BLUE - 7021528920918 1044698 892096 RFOU(I) 12TRIP 0.75mm² S1/S5 GREY - 7021528920963 1044699 892097 RFOU(I) 12TRIP 0.75mm² S1/S5 BLUE - 7021528920970 1044700 892102 RFOU(I) 16TRIP 0.75mm² S1/S5 GREY - 7021528921021 1044701 892103 RFOU(I) 16TRIP 0.75mm² S1/S5 BLUE - 7021528921038 1044702 892106 RFOU(I) 19TRIP 0.75mm² S1/S5 GREY - 7021528921069 - 892108 RFOU(I) 24TRIP 0.75mm² S1/S5 GREY - 7021528921083 1044707 892109 RFOU(I) 24TRIP 0.75mm² S1/S5 BLUE - 7021528921090 1044708 892200 RFOU(I) 1PAIR 1.5mm² S1/S5 GREY Yes 7021528922004 1044460 892201 RFOU(I) 1PAIR 1.5mm² S1/S5 BLUE - 7021528922011 1044459 892206 RFOU(I) 2PAIR 1.5mm² S1/S5 GREY - 7021528922066 1044661 892207 RFOU(I) 2PAIR 1.5mm² S1/S5 BLUE - 7021528922073 1044662 892218 RFOU(I) 4PAIR 1.5mm² S1/S5 GREY - 7021528922189 1044663 892219 RFOU(I) 4PAIR 1.5mm² S1/S5 BLUE - 7021528922196 1044664 892230 RFOU(I) 8PAIR 1.5mm² S1/S5 GREY - 7021528922301 1044668 892231 RFOU(I) 8PAIR 1.5mm² S1/S5 BLUE - 7021528922318 1044669 892236 RFOU(I) 12PAIR 1.5mm² S1/S5 GREY - 7021528922363 1044670 892237 RFOU(I) 12PAIR 1.5mm² S1/S5 BLUE - 7021528922370 1044671 892242 RFOU(I) 16PAIR 1.5mm² S1/S5 GREY - 7021528922424 1044673 892243 RFOU(I) 16PAIR 1.5mm² S1/S5 BLUE - 7021528922431 1044672 892245 RFOU(I) 19PAIR 1.5mm² S1/S5 GREY - 7021528922455 1044674 892246 RFOU(I) 19PAIR 1.5mm² S1/S5 BLUE - 7021528922462 1044675 892248 RFOU(I) 24PAIR 1.5mm² S1/S5 GREY - 7021528922486 1044678 892249 RFOU(I) 24PAIR 1.5mm² S1/S5 BLUE - 7021528922493 1044679

www.drakaMOG.com Subject to change without prior notice

274

Page 282: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU(I) 250V(3).doc 03/06/2008 10:46:00

Page 5 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable

www.drakaMOG.com Subject to change without prior notice

Part number Description Sheath Colour Stock item EAN No. DNK EL No. 892254 RFOU(I) 32PAIR 1.5mm² S1/S5 GREY - 7021528922547 - 892255 RFOU(I) 32PAIR 1.5mm² S1/S5 BLUE - 7021528922554 - 892260 RFOU(I) 1TRIP 1.5mm² S1/S5 GREY Yes 7021528922608 1044560 892261 RFOU(I) 1TRIP 1.5mm² S1/S5 BLUE - 7021528922615 1044559 892266 RFOU(I) 2TRIP 1.5mm² S1/S5 GREY - 7021528922660 1044762 892278 RFOU(I) 4TRIP 1.5mm² S1/S5 GREY - 7021528922783 1044764 892279 RFOU(I) 4TRIP 1.5mm² S1/S5 BLUE - 7021528922790 1044765 892290 RFOU(I) 8TRIP 1.5mm² S1/S5 GREY - 7021528922905 1044768 892291 RFOU(I) 8TRIP 1.5mm² S1/S5 BLUE - 7021528922912 1044769 892296 RFOU(I) 12TRIP 1.5mm² S1/S5 GREY - 7021528922967 1044770 892297 RFOU(I) 12TRIP 1.5mm² S1/S5 BLUE - 7021528922974 1044771 892302 RFOU(I) 16TRIP 1.5mm² S1/S5 GREY - 7021528923025 1044773 892303 RFOU(I) 16TRIP 1.5mm² S1/S5 BLUE - 7021528923032 1044772 892308 RFOU(I) 24TRIP 1.5mm² S1/S5 GREY - 7021528923087 1044779 892309 RFOU(I) 24TRIP 1.5mm² S1/S5 BLUE - 7021528923094 1044780 892400 RFOU(I) 1PAIR 2.5mm² S1/S5 GREY - 7021528924008 - 892406 RFOU(I) 2PAIR 2.5mm² S1/S5 GREY - 7021528924060 - 892418 RFOU(I) 4PAIR 2.5mm² S1/S5 GREY - 7021528924183 -

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

275

Page 283: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU-HCF-12kv-HF_2006.doc 30.06.2006 08:49

Page 1 of 3

RFOU-HCF 6/10(12)kV P30 / 1100°C / 30-60 minutes

www.drakaMOG.com Subject to change without prior notice

HydroCarbon Fire resistant, flame retardant halogen-free medium voltage power cable.

RFOU-HCF 6/10(12)kVEPR/EPR/TCWB/EVA/HCF/SHF1

NEK 606 Code P30

1100°C / 2000°F / 200 kW/m²

Operating temperature : 90°CO perating Voltage : 6/10(12)kV

Application

Fixed installation for medium voltage (MV) power in both EX- and safe areas, emergency and critical systems

re requirement for fire resistance is vital. whe

Standards applied

IEC 60092-354 - Design Draka Norsk Kabel - HCF protection IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60331-21 - Fire Resistant UL 1709 / ASTM E1529 - HC Fire resistance IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter Conductor Tinned stranded and compressed copper (STCC), IEC 60228 class 2 Conductor screen semiconductive

Semiconductive layer (EP-rubber)

Insulation R EP-rubber, IEC 60092-351 (EPR) Insulation screen semicoductive

Semiconductive layer (EP-rubber)

Lay up / Shielding Cores are laid up together. Cores are identified by White, Black or Red threads under and over the metallic screen on each conductor.

Inner covering F Flame retardant and halogen-free thermoset compound Tape over bedding

PET tape

Armour/screen O Tinned copper wire braid Tape over armour/screen

PET tape

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

276

Page 284: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU-HCF-12kv-HF_2006.doc 30.06.2006 08:49

Page 2 of 3

RFOU-HCF 6/10(12)kV P30 / 1100°C / 30-60 minutes

www.drakaMOG.com Subject to change without prior notice

Code Letter HCF protection -HCF Extruded heatblock compound Tape Lapped glassfibre tape

Overall sheath Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-359)

Marking text Eg. "meter" "år" DRAKA NORSK KABEL RFOU-HCF 6/10(12)kV P30 1x 70/16 mm2 HCF 1100/60 FLEX - FLAME

Outer sheath colour

Red

Range and dimensions

Draka Norsk Kabel

part no.

Type

[mm2]

Diameter over bedding

[mm]

Thickness ofarmour wires

[mmØ]

Diameter sheath

[mm]

Diameter overall HCF-

protection

(mm)

Weight of cable approx. [kg/km]

886498 1x 70/16 23,5±1,5 0,3 30,0±2,0 62,0±3,0 5220

1x 95/16 25,5±1,5 0,3 32,0±2,0 64,5±3,0 5900 1x 120/20 27,5±1,5 0,3 34,0±2,0 66,5±3,0 6340 1x 150/19 28,5±1,5 0,3 35,0±2,0 67,5±3,0 6670 1x 185/18 30,5±1,5 0,3 36,5±2,0 69,0±3,0 7320 1x 240/21 33,0±1,5 0,3 39,0±2,0 72,0±3,5 8250 1x 300/29 35,0±1,5 0,3 41,5±2,5 74,5±3,5 9280 3x 50/31 47,0±2,0 0,4 55,0±3,0 89,0±4,5 10970 3x 95/50 54,0±2,0 0,4 62,5±3,5 97,0±5,0 14230 3x 150/75 60,0±2,5 0,6 70,5±3,0 106,0±6,0 17400

Type

(mm²)

Diameter of copper

conductor approx. mmØ

Insulation thickness, nominal

mm

Semi-conducting

layer thickness

approx. mm

Diameter over insulated, screened

conductor, approx. mm

1x 70/16 10,3 3,4 0,8 21,5 1x 95/16 12,1 3,4 0,8 23,0

1x 120/20 13,6 3,4 0,8 24,5 1x 150/19 15,1 3,4 0,8 26,0 1x 185/18 16,8 3,4 0,8 28,0 1x 240/21 19,1 3,4 0,8 30,0 1x 300/29 21.5 3,4 0,8 32,5

3x 50/31 8,8 3,4 0,8 20,0 3x 95/50 12,1 3,4 0,8 23,0

3x 150/75 15,1 3,4 0,8 26,0

277

Page 285: Prysmian Draka - Marine & Offshore LV HV Cables

RFOU-HCF-12kv-HF_2006.doc 30.06.2006 08:49

Page 3 of 3

RFOU-HCF 6/10(12)kV P30 / 1100°C / 30-60 minutes

www.drakaMOG.com Subject to change without prior notice

ELECTRICAL DATA

No. of cores x cross section

Conductor resistance DC

[Ω/km]

Reactance[Ω/km]

Impedance [Ω/km] at 90

°C

Continous current rating

Short circuit (conductor) [Ampere]

[mm2] at 20 °C at 90 °C at 50 Hz at 50 Hz at 45 °C 1 sec 0,3 sec

1x 70/16 0,270 0,344 0,172 0,385 242 9800 17892 1x 95/16 0,195 0,249 0,164 0,298 293 13300 24282 1x 120/20 0,154 0,196 0,159 0,253 339 16800 30672 1x 150/19 0,126 0,161 0,153 0,222 389 21000 38340 1x 185/18 0,100 0,128 0,148 0,195 444 25900 47286 1x 240/21 0,0762 0,0972 0,143 0,173 522 33600 61344 1x 300/29 0,0607 0,0774 0,137 0,158 601 42000 76681

3x 50/31 0,391 0,499 0,108 0,261 137 7000 12780 3x 95/50 0,195 0,249 0,098 0,268 205 13300 24282 3x 150/75 0,1126 0,161 0,092 0,185 272 21000 38340

INSTALLATION DATA

TYPE

[mm2]

Overall Diameter [mmØ]

Minimum bending radius During Fixed

Installation Installed [mm]

Maximum pulling tension

[N]

20 x D 12 x D

1 x70/16 62,0±3,0 1240 744 3500 1x 95/16 64,5±3,0 1290 774 4750 1x 120/20 66,5±3,0 1330 798 6000 1x 150/19 67,5±3,0 1350 810 7500 1x 185/18 69,0±3,0 1380 828 9250 1x 240/21 72,0±3,5 1440 864 12000 1x 300/29 74,5±3,5 1490 894 15000

3x 50/31 89,0±4,5 1780 1068 7500 3x 95/50 97,0±5,0 1940 1164 14250 3x 150/75 106,0±6,0 2120 1272 20000

Minimum installation temperature: - 10 °C

278

Page 286: Prysmian Draka - Marine & Offshore LV HV Cables

RU 1kV(3).doc 29.12.2006 10:47

Page 1 of 6

RU 0,6/1kV P18, Power cable, Unarmoured

Flame retardant halogen-free power cable. Mud resistant

RU 0,6/1kVEPR/EVA

NEK 606 CodeP18 Operating temperature : 90°CO perating Voltage : 0,6/1kV

Application

Fixed installation for power,control and lighting in both EX- and safe areas, general purposes. For installation in areas exposed to

UD and drilling/cleaning fluids. M

Standards applied

IEC 60092-353 - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

www.drakaMOG.com Subject to change without prior notice

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation R EP-rubber, IEC 60092-351 (EPR) Lay up / Shielding Cores laid up in concentric layers Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour.

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "year" DRAKA NORSK KABEL RU 0,6/1KV P18 3 x 2,5 mm2 IEC 60332-3-22

Outer sheath colour

Black

279

Page 287: Prysmian Draka - Marine & Offshore LV HV Cables

RU 1kV(3).doc 29.12.2006 10:47

Page 2 of 6

RU 0,6/1kV P18, Power cable, Unarmoured

Core identification power cables Single core Grey (Offwhite) Two cores Grey (Offwhite) - Black Three cores Grey (Offwhite) - Black - Red Four cores Grey (Offwhite) - Black - Red - Blue Five cores Grey (Offwhite) - Black - Red - Blue - Black Above five cores Black numbers on white base Separate earth core Yellow/green G / x in cable description G = one of the core are yellow/green - x = no yellow/green core From Q3 2007 the core colours on RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow Cenelec HD 308S2 colours: Single core Black Two cores Blue - Brown Two cores + earth Blue - Brown - Yellow/green Three cores Brown - Black - Grey Three cores + earth Brown - Black - Grey - Yellow/green Four cores Blue - Brown - Black - Grey Four cores + earth Blue - Brown - Black - Grey - Yellow/green Five cores Blue - Brown - Black - Grey - Black Above five cores Black numbers on white base

Range and dimensions

www.drakaMOG.com Subject to change without prior notice

Number of elements

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 50 9.0 1.4 1.2 14.5 ± 0.8 600 428 1 70 10.9 1.4 1.3 16.5 ± 0.8 820 620 1 95 12.60 1.6 1.4 19 ± 0.8 1100 836 1 120 14.20 1.6 1.4 20.5 ± 1 1370 1075 1 150 15.90 1.8 1.5 23 ± 1 1690 1336 1 185 17.7 2.0 1.6 25 ± 1 2070 1663 1 240 20.15 2.2 1.7 28.5 ± 1 2690 2173 1 300 22.60 2.4 1.8 31.5 ± 1.5 3360 2751 2 1.5 1.6 1.0 1.1 9.5 ± 0.5 135 28 3G 1.5 1.6 1.0 1.1 10 ± 0.8 160 42 3 1.5 1.6 1.0 1.1 10 ± 0.8 160 42 4G 1.5 1.6 1.0 1.1 11 ± 0.8 190 56 4 1.5 1.6 1.0 1.1 11 ± 0.8 190 56 7G 1.5 1.6 1.0 1.2 13.5 ± 0.8 290 97 5 1.5 1.6 1.0 1.2 12 ± 0.8 240 70 7 1.5 1.6 1.0 1.2 13.5 ± 0.8 290 98 12 1.5 1.6 1.0 1.4 18 ± 0.8 480 167 19 1.5 1.6 1.0 1.5 21 ± 1 700 264 24 1.5 1.6 1.0 1.6 25 ± 1 890 333 2 2.5 2.0 1.0 1.1 10.5 ± 0.8 170 46 3G 2.5 2.0 1.0 1.1 11 ± 0.8 205 69 3 2.5 2.0 1.0 1.1 11 ± 0.8 205 69 4G 2.5 2.0 1.0 1.2 12 ± 0.8 255 92 4 2.5 2.0 1.0 1.2 12 ± 0.8 250 92 5G 2.5 2.0 1.0 1.2 13.5 ± 0.8 320 114

280

Page 288: Prysmian Draka - Marine & Offshore LV HV Cables

RU 1kV(3).doc 29.12.2006 10:47

Page 3 of 6

RU 0,6/1kV P18, Power cable, Unarmoured

www.drakaMOG.com Subject to change without prior notice

Number of elements

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

7 2.5 2.0 1.0 1.3 14.5 ± 0.8 390 160 2 4 2.55 1.0 1.2 11.5 ± 0.8 225 74 3G 4 2.55 1.0 1.2 12 ± 0.8 275 110 3 4 2.55 1.0 1.2 12 ± 0.8 275 110 4G 4 2.55 1.0 1.2 13.5 ± 0.8 340 147 4 4 2.55 1.0 1.2 13.5 ± 0.8 340 147 5G 4 2.55 1.0 1.3 15 ± 0.8 410 183 2 6 3.15 1.0 1.2 12.5 ± 0.8 290 109 3G 6 3.15 1.0 1.2 13.5 ± 0.8 360 164 3 6 3.15 1.0 1.2 13.5 ± 0.8 380 163 4 6 3.15 1.0 1.3 15 ± 0.8 450 218 5G 6 3.15 1.0 1.3 16.5 ± 0.8 550 272 4G 6 3.15 1.0 1.3 15 ± 0.8 450 218 2 10 4.05 1.0 1.2 14.5 ± 0.8 410 181 3 10 4.05 1.0 1.3 15.5 ± 0.8 520 271 4G 10 4.05 1.0 1.3 17.5 ± 0.8 660 361 5G 10 4.05 1.0 1.4 19 ± 0.8 820 451 3 16 5.15 1.0 1.4 18 ± 0.8 760 434 4 16 5.15 1.0 1.4 20 ± 1 950 579 3G 16 5.15 1.0 1.4 18.5 ± 0.8 770 434 4G 16 5.15 1.0 1.4 20 ± 1 970 578 5G 16 5.15 1.0 1.5 22.5 ± 1 1190 722 4 25 6.45 1.2 1.6 24.5 ± 1 1420 916 4G 25 6.45 1.2 1.6 25 ± 1 1490 917 2 35 7.65 1.2 1.5 23 ± 1 1150 618 4G 35 7.65 1.2 1.7 28 ± 1 1920 1236 5G 35 7.65 1.2 1.8 31 ± 1.5 2340 1544 3 50 9.0 1.4 1.8 29 ± 1 2050 1287 5G 50 9.0 1.4 2 36.5 ± 1.5 3280 2144 3 70 10.85 1.4 2 33.5 ± 1.5 2840 1863 5G 70 10.85 1.4 2.1 42 ± 2 4480 3105

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

831703 RU 0.6/1kV 1X 50mm² P18 BLACK - 7021528317039 1061403 831704 RU 0,6/1KV 1X 70 MM2 P18 BLACK - 7021528317046 - 831705 RU 0.6/1kV 1X 95mm² P18 BLACK - 7021528317053 - 831706 RU 0.6/1kV 1X 120mm² P18 BLACK - 7021528317060 - 831707 RU 0.6/1kV 1X 150mm² P18 BLACK - 7021528317077 1061407 831708 RU 0,6/1KV 1X185 MM2 P18 BLACK - 7021528317084 - 831709 RU 0.6/1kV 1X 240mm² P18 BLACK - 7021528317091 - 831710 RU 0.6/1kV 1X 300mm² P18 BLACK - 7021528317107 - 831715 RU 0.6/1kV 2X 1.5mm² P18 BLACK - 7021528317152 - 831716 RU 0.6/1kV 3G 1.5mm² P18 BLACK - 7021528317169 - 831718 RU 0.6/1kV 3X 1.5mm² P18 BLACK - 7021528317183 - 831719 RU 0.6/1kV 4G 1.5mm² P18 BLACK - 7021528317190 - 831721 RU 0.6/1kV 4X 1.5mm² P18 BLACK - 7021528317213 - 831723 RU 0.6/1kV 7G 1.5mm² P18 BLACK - 7021528317237 - 831724 RU 0.6/1kV 5X 1.5mm² P18 BLACK - 7021528317244 - 831725 RU 0.6/1kV 7X 1.5mm² P18 BLACK - 7021528317251 -

281

Page 289: Prysmian Draka - Marine & Offshore LV HV Cables

RU 1kV(3).doc 29.12.2006 10:47

Page 4 of 6

RU 0,6/1kV P18, Power cable, Unarmoured

www.drakaMOG.com Subject to change without prior notice

Part number Description Sheath Colour Stock item EAN No. DNK EL No. 831726 RU 0,6/1KV 12X 1,5 MM2 P18 BLACK - 7021528317268 - 831728 RU 0.6/1kV 19X 1.5mm² P18 BLACK - 7021528317282 - 831729 RU 0,6/1KV 24X 1,5 MM2 P18 BLACK - 7021528317299 - 831733 RU 0.6/1kV 2X 2.5mm² P18 BLACK - 7021528317336 - 831734 RU 0.6/1kV 3G 2.5mm² P18 BLACK - 7021528317343 1061434 831736 RU 0.6/1kV 3X 2.5mm² P18 BLACK - 7021528317367 - 831737 RU 0.6/1kV 4G 2.5mm² P18 BLACK - 7021528317374 1061437 831739 RU 0,6/1KV 4X 2,5 MM2 P18 BLACK - 7021528317398 - 831740 RU 0.6/1kV 5G 2.5mm² P18 BLACK - 7021528317404 - 831743 RU 0,6/1KV 7X 2,5 MM2 P18 BLACK - 7021528317435 - 831751 RU 0,6/1KV 2X 4 MM2 P18 BLACK - 7021528317510 - 831752 RU 0.6/1kV 3G 4mm² P18 BLACK - 7021528317527 - 831753 RU 0.6/1kV 3X 4mm² P18 BLACK - 7021528317534 - 831754 RU 0.6/1kV 4G 4mm² P18 BLACK - 7021528317541 - 831755 RU 0,6/1KV 4X 4 MM2 P18 BLACK - 7021528317558 - 831756 RU 0,6/1KV 5G 4mm² P18 BLACK - 7021528317565 - 831759 RU 0,6/1KV 2X 6 MM2 P18 BLACK - 7021528317596 - 831760 RU 0.6/1kV 3G 6mm² P18 BLACK - 7021528317602 - 831761 RU 0,6/1KV 3X 6MM2 P18 BLACK - 7021528317619 - 831762 RU 0.6/1kV 4X 6mm² P18 BLACK - 7021528317626 - 831763 RU 0.6/1kV 5G 6mm² P18 BLACK - 7021528317633 - 831764 RU 0.6/1kV 4G 6mm² P18 BLACK - 7021528317640 - 831766 RU 0,6/1KV 2X 10 MM2 P18 BLACK - 7021528317664 - 831767 RU 0,6/1KV 3X 10 MM2 P18 BLACK - 7021528317671 - 831769 RU 0.6/1kV 4G 10mm² P18 BLACK - 7021528317695 - 831770 RU 0.6/1kV 5G 10mm² P18 BLACK - 7021528317701 - 831773 RU 0,6/1KV 3X 16 MM2 P18 BLACK - 7021528317732 - 831774 RU 0,6/1KV 4X 16 MM2 P18 BLACK - 7021528317749 - 831775 RU 0.6/1kV 3G 16mm² P18 BLACK - 7021528317756 - 831776 RU 0.6/1kV 4G 16mm² P18 BLACK - 7021528317763 - 831777 RU 0.6/1kV 5G 16mm² P18 BLACK - 7021528317770 - 831781 RU 0,6/1KV 4X 25 MM2 P18 BLACK - 7021528317817 - 831782 RU 0.6/1kV 4G 25mm² P18 BLACK - 7021528317824 - 831785 RU 0,6/1KV 2X 35 MM2 P18 BLACK - 7021528317855 - 831788 RU 0.6/1kV 4G 35mm² P18 BLACK - 7021528317886 - 831789 RU 0.6/1kV 5G 35mm² P18 BLACK - 7021528317893 - 831792 RU 0,6/1KV 3X 50 MM2 P18 BLACK - 7021528317923 - 831796 RU 0.6/1kV 5G 50mm² P18 BLACK - 7021528317961 - 831798 RU 0,6/1KV 3X 70 MM2 P18 BLACK - 7021528317985 - 831799 RU 0.6/1kV 5G 70mm² P18 BLACK - 7021528317992 -

Electrical values power cables Number of elements

Cross section

core, mm²

Max. conductor resistance at

20°C, Ohm/km

Max. conductor resistance at

90°C, Ohm/km

Reactance at 50Hz,

Ohm/km

Reactance at 60Hz,

Ohm/km

Current rating IEC 60092-352

Table B.4, Ampere

Short circuit rating 1 second, Ampere

1 50 0.391 0.499 0.089 0.107 196 7000 1 70 0.27 0.344 0.099 0.120 242 9800 1 95 0.195 0.249 0.084 0.101 293 13300 1 120 0.154 0.196 0.082 0.099 339 16800 1 150 0.126 0.161 0.082 0.098 389 21000 1 185 0.1 0.128 0.081 0.098 444 25900 1 240 0.0762 0.0972 0.080 0.096 522 33600

282

Page 290: Prysmian Draka - Marine & Offshore LV HV Cables

RU 1kV(3).doc 29.12.2006 10:47

Page 5 of 6

RU 0,6/1kV P18, Power cable, Unarmoured

www.drakaMOG.com Subject to change without prior notice

Number of elements

Cross section

core, mm²

Max. conductor resistance at

20°C, Ohm/km

Max. conductor resistance at

90°C, Ohm/km

Reactance at 50Hz,

Ohm/km

Reactance at 60Hz,

Ohm/km

Current rating IEC 60092-352

Table B.4, Ampere

Short circuit rating 1 second, Ampere

1 300 0.0607 0.0774 0.080 0.096 601 42000 2 1.5 12.2 15.6 0.110 0.132 20 210 3G 1.5 12.2 15.6 0.110 0.132 20 210 3 1.5 12.2 15.6 0.110 0.132 16 210 4G 1.5 12.2 15.6 0.110 0.132 16 210 4 1.5 12.2 15.6 0.110 0.132 16 210 7G 1.5 12.2 15.6 0.110 0.132 12.5 210 5 1.5 12.2 15.6 0.110 0.132 13.5 210 7 1.5 12.2 15.6 0.110 0.132 12 210 12 1.5 12.2 15.6 0.110 0.132 10 210 19 1.5 12.2 15.6 0.110 0.132 8.5 210 24 1.5 12.2 15.6 0.110 0.132 8 210 2 2.5 7.56 9.64 0.102 0.123 26 350 3G 2.5 7.56 9.64 0.103 0.123 26 350 3 2.5 7.56 9.64 0.103 0.123 21 350 4G 2.5 7.56 9.64 0.103 0.123 21 350 4 2.5 7.56 9.64 0.103 0.123 21 350 5G 2.5 7.56 9.64 0.103 0.123 21 350 7 2.5 7.56 9.64 0.103 0.123 15.5 350 2 4 4.7 5.99 0.096 0.115 34 560 3G 4 4.7 5.99 0.096 0.115 34 560 3 4 4.7 5.99 0.096 0.115 28 560 4G 4 4.7 5.99 0.096 0.115 28 560 4 4 4.7 5.99 0.096 0.115 28 560 5G 4 4.7 5.99 0.096 0.115 28 560 2 6 3.11 3.97 0.090 0.108 44 840 3G 6 3.11 3.97 0.090 0.108 44 840 3 6 3.11 3.97 0.090 0.108 36 840 4 6 3.11 3.97 0.090 0.108 36 840 5G 6 3.11 3.97 0.090 0.108 36 840 4G 6 3.11 3.97 0.090 0.108 36 840 2 10 1.84 2.35 0.084 0.101 61 1400 3 10 1.84 2.35 0.084 0.101 50 1400 4G 10 1.84 2.35 0.084 0.101 50 1400 5G 10 1.84 2.35 0.084 0.101 50 1400 3 16 1.16 1.48 0.080 0.096 67 2240 4 16 1.16 1.48 0.080 0.096 67 2240 3G 16 1.16 1.48 0.080 0.096 80 2240 4G 16 1.16 1.48 0.080 0.096 67 2240 5G 16 1.16 1.48 0.103 0.123 67 2240 4 25 0.734 0.936 0.079 0.095 89 3500 4G 25 0.734 0.936 0.079 0.095 89 3500 2 35 0.529 0.675 0.076 0.092 133 4900 4G 35 0.529 0.675 0.076 0.092 110 4900 5G 35 0.529 0.675 0.076 0.092 110 4900 3 50 0.391 0.499 0.076 0.092 137 7000 5G 50 0.391 0.499 0.076 0.092 137 7000 3 70 0.27 0.344 0.075 0.091 169 9800 5G 70 0.27 0.344 0.076 0.092 169 9800

283

Page 291: Prysmian Draka - Marine & Offshore LV HV Cables

RU 1kV(3).doc 29.12.2006 10:47

Page 6 of 6

RU 0,6/1kV P18, Power cable, Unarmoured

Ambient temperature correction factors Ambient Temp °C 35 40 45 50 55 60 65 70 75 80 Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

www.drakaMOG.com Subject to change without prior notice

284

Page 292: Prysmian Draka - Marine & Offshore LV HV Cables

RU(c) 250V(3).doc 29.12.2006 10:15

Page 1 of 3

RU(c) 250V S12 Instrumentation cable, Unarmoured

Flame retardant halogen-free instrumentation cable. Mud resistant

RU(c) 250VEPR/EVA

NEK 606 CodeS12 Operating temperature : 90°CO perating Voltage : 250V

Application

Fixed installation for instrumentation, communication, Control and alarm systems in both EX- (Zone 2) and safe areas.

eets the mud resistant requirements in NEK 606. M

Standards applied

IEC 60092-376 (2003-05) - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame RetardantIEC 60332-3-22 - Flame RetardantIEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

www.drakaMOG.com Subject to change without prior notice

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation R EP-rubber, IEC 60092-351 (EPR)

Pair / Triple / Quad twisting

Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs/triples are identified by numbers printed directly on the insulated conductors.

Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour.

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "year" DRAKA NORSK KABEL RU(c) 250V S12 2 pair 0,75 mm2 IEC 60092-376 IEC 60332-3-22

Outer sheath colour

Grey or Blue

Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Quad Black - Light Blue - Brown - Grey

285

Page 293: Prysmian Draka - Marine & Offshore LV HV Cables

RU(c) 250V(3).doc 29.12.2006 10:15

Page 2 of 3

RU(c) 250V S12 Instrumentation cable, Unarmoured

Range and dimensions

Number of elements

No of cores in element

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

2 2 0.75 1.1 0.6 1.1 10 ± 0.8 140 33 4 2 0.75 1.1 0.6 1.1 11.5 ± 0.8 200 60 8 2 0.75 1.1 0.6 1.3 16 ± 0.8 410 116 12 2 0.75 1.1 0.6 1.4 18 ± 0.8 530 172 16 2 0.75 1.1 0.6 1.5 19.5 ± 0.8 660 227 19 2 0.75 1.1 0.6 1.5 20.5 ± 1 750 269 24 2 0.75 1.1 0.6 1.7 24 ± 1 950 338 2 3 0.75 1.1 0.6 1.1 11 ± 0.8 170 47 4 3 0.75 1.1 0.6 1.2 13 ± 0.8 270 89 8 3 0.75 1.1 0.6 1.4 17.5 ± 0.8 530 172 16 3 0.75 1.1 0.6 1.6 22 ± 1 900 341 24 3 0.75 1.1 0.6 1.8 27 ± 1 1300 508 2 2 1.5 1.6 0.7 1.2 12 ± 0.8 210 62 4 2 1.5 1.6 0.7 1.2 14 ± 0.8 320 118 8 2 1.5 1.6 0.7 1.4 19.5 ± 0.8 630 229 12 2 1.5 1.6 0.7 1.6 22.5 ± 1 850 339 12 2 1.5 1.6 0.7 1.6 22.5 ± 1 850 339 16 2 1.5 1.6 0.7 1.7 24.5 ± 1 1080 450 24 2 1.5 1.6 0.7 1.9 30 ± 1.5 1550 672 2 3 1.5 1.6 0.7 1.2 13.5 ± 0.8 265 91 4 3 1.5 1.6 0.7 1.3 16 ± 0.8 430 174 8 3 1.5 1.6 0.7 1.5 21.5 ± 1 840 341 12 3 1.5 1.6 0.7 1.7 25.5 ± 1 1170 509 16 3 1.5 1.6 0.7 1.8 27.5 ± 1 1500 676 24 3 1.5 1.6 0.7 2.1 34 ± 1.5 2210 1010

Electrical values instrumentation cables

Type Capacitance, approx. (nF/km)

Inductance, approx, (mH/km)

Resistance at 20°C, max. (Ohm/km)

L/R ratio, (microH/Ohm)

Unshielded pair 0,75 mm² 100 0,67 24,8 14,3 Unshielded triple 0,75 mm² 100 0,67 24,8 14,3 Unshielded pair 1,5 mm² 110 0,63 12,2 26,6 Unshielded triple 1,5 mm² 110 0,63 12,2 26,6 Unshielded pair 2,5 mm² 125 0,59 7,56 39,0 Unshielded triple 2,5 mm² 125 0,59 7,56 39,0

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

895606 RU(C) 250V 2PAIR 0.75mm² S12 GREY - 7021528956061 - 895618 RU(C) 250V 4PAIR 0.75mm² S12 GREY - 7021528956184 - 895630 RU(C) 250V 8PAIR 0.75mm² S12 GREY - 7021528956306 - 895636 RU(C) 250V 12PAIR 0.75mm² S12 GREY - 7021528956368 - 895642 RU(C) 250V 16PAIR 0.75mm² S12 GREY - 7021528956429 - 895645 RU(C) 250V 19PAIR 0.75mm² S12 GREY - 7021528956450 - 895648 RU(C) 250V 24PAIR 0.75mm² S12 GREY - 7021528956481 - 895666 RU(C) 250V 2TRIP 0.75mm² S12 GREY - 7021528956665 -

www.drakaMOG.com Subject to change without prior notice

286

Page 294: Prysmian Draka - Marine & Offshore LV HV Cables

RU(c) 250V(3).doc 29.12.2006 10:15

Page 3 of 3

RU(c) 250V S12 Instrumentation cable, Unarmoured

www.drakaMOG.com Subject to change without prior notice

Part number Description Sheath Colour Stock item EAN No. DNK EL No.895678 RU(C) 250V 4TRIP 0.75mm² S12 GREY - 7021528956788 - 895690 RU(C) 250V 8TRIP 0.75mm² S12 GREY - 7021528956900 - 895702 RU(C) 250V 16TRIP 0.75mm² S12 GREY - 7021528957020 - 895708 RU(C) 250V 24TRIP 0.75mm² S12 GREY - 7021528957082 - 895806 RU(C) 250V 2PAIR 1.5mm² S12 GREY - 7021528958065 - 895818 RU(C) 250V 4PAIR 1.5mm² S12 GREY - 7021528958188 - 895830 RU(C) 250V 8PAIR 1.5mm² S12 GREY - 7021528958300 - 895836 RU(C) 250V 12PAIR 1.5mm² S12 GREY - 7021528958362 - 895837 RU(C) 250V 12PAIR 1.5mm² S12 BLUE - 7021528958379 - 895842 RU(C) 250V 16PAIR 1.5mm² S12 GREY - 7021528958423 - 895848 RU(C) 250V 24PAIR 1.5mm² S12 GREY - 7021528958485 - 895866 RU(C) 250V 2TRIP 1.5mm² S12 GREY - 7021528958669 - 895878 RU(C) 250V 4TRIP 1.5mm² S12 GREY - 7021528958782 - 895890 RU(C) 250V 8TRIP 1.5mm² S12 GREY - 7021528958904 - 895896 RU(C) 250V 12TRIP 1.5mm² S12 GREY - 7021528958966 - 895902 RU(C) 250V 16TRIP 1.5mm² S12 GREY - 7021528959024 - 895908 RU(C) 250V 24TRIP 1.5mm² S12 GREY - 7021528959086 -

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

287

Page 295: Prysmian Draka - Marine & Offshore LV HV Cables

RU(i) 250V(4).doc 29.12.2006 10:09

Page 1 of 3

RU(i) 250V S11 Instrumentation cable, Unarmoured

Flame retardant halogen-free instrumentation cable. Mud resistant

RU(i) 250VEPR/EVA

NEK 606 CodeS11 Operating temperature : 90°CO perating Voltage : 250V

Application

Fixed installation for instrumentation, communication, Control and alarm systems in both EX- (Zone 2) and safe

reas. Meets the mud resistant requirements in NEK 606. a

Standards applied

IEC 60092-376 (2003-05) - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

www.drakaMOG.com Subject to change without prior notice

Code Letter

Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Insulation R EP-rubber, IEC 60092-351 (EPR)

Pair / Triple / Quad twisting

Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbers printed directly on the insulated conductors.

Lay up / Shielding

Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape.

Inner covering No inner covering. (Additional tapes may be applied) Armour/screen No armour.

Outer sheath U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-359)

Marking text E.g. "meter" "year" DRAKA NORSK KABEL RU(i) 250V S11 2 pair 0,75 mm2 IEC 60092-376 IEC 60332-3-22

Outer sheath colour

Grey or Blue

Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Quad Black - Light Blue - Brown - Grey

288

Page 296: Prysmian Draka - Marine & Offshore LV HV Cables

RU(i) 250V(4).doc 29.12.2006 10:09

Page 2 of 3

RU(i) 250V S11 Instrumentation cable, Unarmoured

Range and dimensions

www.drakaMOG.com Subject to change without prior notice

Number of elements

No of cores in element

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 2 0.75 1.1 0.6 1 6.5 ± 0.5 85 18.5 1 2 0.75 1.1 0.6 1 6.5 ± 0.5 85 18.5 2 2 0.75 1.1 0.6 1.1 10 ± 0.8 145 37 2 2 0.75 1.1 0.6 1.1 10 ± 0.8 145 37 4 2 0.75 1.1 0.6 1.2 11.5 ± 0.8 240 74 8 2 0.75 1.1 0.6 1.3 16 ± 0.8 450 147 12 2 0.75 1.1 0.6 1.5 19 ± 0.8 630 220 16 2 0.75 1.1 0.6 1.5 21 ± 1 790 293 24 2 0.75 1.1 0.6 1.7 25.5 ± 1 1160 439 1 3 0.75 1.1 0.6 1 7 ± 0.5 100 26 2 3 0.75 1.1 0.6 1.2 11 ± 0.8 185 51 4 3 0.75 1.1 0.6 1.2 13 ± 0.8 300 102 8 3 0.75 1.1 0.6 1.4 17.5 ± 0.8 580 203 12 3 0.75 1.1 0.6 1.6 21.5 ± 1 810 305 16 3 0.75 1.1 0.6 1.6 23.5 ± 1 1030 406 24 3 0.75 1.1 0.6 1.9 29.5 ± 1 1540 609 1 2 1.5 1.6 0.7 1 8 ± 0.5 120 35 1 2 1.5 1.6 0.7 1 8 ± 0.5 120 35 2 2 1.5 1.6 0.7 1.2 12 ± 0.8 220 69 2 2 1.5 1.6 0.7 1.2 12 ± 0.8 220 69 4 2 1.5 1.6 0.7 1.3 14.5 ± 0.8 370 137 8 2 1.5 1.6 0.7 1.5 19.5 ± 0.8 710 274 12 2 1.5 1.6 0.7 1.6 23.5 ± 1 980 411 16 2 1.5 1.6 0.7 1.7 26.5 ± 1 1270 548 24 2 1.5 1.6 0.7 2 32.5 ± 1.5 1900 822 1 3 1.5 1.6 0.7 1 8.5 ± 0.5 140 49 2 3 1.5 1.6 0.7 1.3 14 ± 0.8 285 97 4 3 1.5 1.6 0.7 1.3 16 ± 0.8 470 194 8 3 1.5 1.6 0.7 1.6 22 ± 1 920 387 16 3 1.5 1.6 0.7 1.9 30 ± 1.5 1710 774 24 3 1.5 1.6 0.7 2.2 37 ± 1.5 2540 1161

Electrical values instrumentation cables

Type Capacitance, approx. (nF/km)

Inductance, approx, (mH/km)

Resistance at 20°C, max. (Ohm/km)

L/R ratio, (microH/Ohm)

Shielded pair 0,75 mm² 110 0,67 24,8 14,3 Shielded triple 0,75 mm² 110 0,67 24,8 14,3 Shielded pair 1,5 mm² 125 0,63 12,2 26,6 Shielded triple 1,5 mm² 125 0,63 12,2 26,6 Shielded pair 2,5 mm² 145 0,59 7,56 39,0 Shielded triple 2,5 mm² 145 0,59 7,56 39,0

Ordering information Part number Description Sheath Colour Stock item EAN No. DNK EL No.

895000 RU(I) 250V 1PAIR 0.75mm² S11 GREY - 7021528950007 - 895001 RU(I) 250V 1PAIR 0.75mm² S11 BLUE - 7021528950014 - 895006 RU(I) 250V 2PAIR 0.75mm² S11 GREY - 7021528950069 -

289

Page 297: Prysmian Draka - Marine & Offshore LV HV Cables

RU(i) 250V(4).doc 29.12.2006 10:09

Page 3 of 3

RU(i) 250V S11 Instrumentation cable, Unarmoured

www.drakaMOG.com Subject to change without prior notice

Part number Description Sheath Colour Stock item EAN No. DNK EL No.895007 RU(I) 250V 2PAIR 0.75mm² S11 BLUE - 7021528950076 - 895018 RU(I) 250V 4PAIR 0.75mm² S11 GREY - 7021528950182 - 895030 RU(I) 250V 8PAIR 0.75mm² S11 GREY - 7021528950304 - 895036 RU(I) 250V 12PAIR 0.75mm² S11 GREY - 7021528950366 - 895042 RU(I) 250V 16PAIR 0.75mm² S11 GREY - 7021528950427 - 895048 RU(I) 250V 24PAIR 0.75mm² S11 GREY - 7021528950489 - 895060 RU(I) 250V 1TRIP 0.75mm² S11 GREY - 7021528950601 - 895066 RU(I) 250V 2TRIP 0.75mm² S11 GREY - 7021528950663 - 895078 RU(I) 250V 4TRIP 0.75mm² S11 GREY - 7021528950786 - 895090 RU(I) 250V 8TRIP 0.75mm² S11 GREY - 7021528950908 - 895096 RU(I) 250V 12TRIP 0.75mm² S11 GREY - 7021528950960 - 895102 RU(I) 250V 16TRIP 0.75mm² S11 GREY - 7021528951028 - 895108 RU(I) 250V 24TRIP 0.75mm² S11 GREY - 7021528951080 - 895200 RU(I) 250V 1PAIR 1.5mm² S11 GREY - 7021528952001 - 895201 RU(I) 250V 1PAIR 1.5mm² S11 BLUE - 7021528952018 - 895206 RU(I) 250V 2PAIR 1.5mm² S11 GREY - 7021528952063 - 895207 RU(I) 250V 2PAIR 1.5mm² S11 BLUE - 7021528952070 - 895218 RU(I) 250V 4PAIR 1.5mm² S11 GREY - 7021528952186 - 895230 RU(I) 250V 8PAIR 1.5mm² S11 GREY - 7021528952308 - 895236 RU(I) 250V 12PAIR 1.5mm² S11 GREY - 7021528952360 - 895242 RU(I) 250V 16PAIR 1.5mm² S11 GREY - 7021528952421 - 895248 RU(I) 250V 24PAIR 1.5mm² S11 GREY - 7021528952483 - 895260 RU(I) 250V 1TRIP 1.5mm² S11 GREY - 7021528952605 - 895266 RU(I) 250V 2TRIP 1.5mm² S11 GREY - 7021528952667 - 895278 RU(I) 250V 4TRIP 1.5mm² S11 GREY - 7021528952780 - 895290 RU(I) 250V 8TRIP 1.5mm² S11 GREY - 7021528952902 - 895302 RU(I) 250V 16TRIP 1.5mm² S11 GREY - 7021528953022 - 895308 RU(I) 250V 24TRIP 1.5mm² S11 GREY - 7021528953084 -

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 8 x D 6 x D 50 N /mm² -20°C

290

Page 298: Prysmian Draka - Marine & Offshore LV HV Cables

UX 1000V.doc 26.03.2006 19:12

Page 1 of 2

UX 1000V P15

21 3 Flame retardant conductors UX 1000V Halogen-free, NEK 606 Type: P15 Maximum operating Conductor temperature : 90°C Operating voltage : 1000V

Application Insulated conductor for earthing and bonding services. Mud resistant in accordance with NEK 606.

Standards applied IEC:60092-353 & NEK 606 - Design guidelines IEC:60332-3-22 - Flame retardance IEC:60754-1,2 - Halogen-free properties IEC:61034-1,2 - Smoke density

CONSTRUCTION

CODE LETTER Conductor

Tinned, stranded copper. (1) PETP-tape. (2)

Insulation

U Flame retardant halogen-free thermoset compound. (3)

Unsheathed X

Marking

E.g; ”meter” ”year” DRAKA NORSK KABEL UX 1000V P15 1x 95 mm² IEC 332-3-22

Colour Yellow/green

www.drakaMOG.com Subject to change without prior notice

291

Page 299: Prysmian Draka - Marine & Offshore LV HV Cables

UX 1000V.doc 26.03.2006 19:12

Page 2 of 2

UX 1000V P15

www.drakaMOG.com Subject to change without prior notice

RANGE AND DIMENSIONS: UX 1000V Insulated conductor, P15 Conductor area

(mm²)

Conductor diameter approx. (mm)

Insulation thickness

(mm)

Diameter over

insulation (mm)

Weight of conductor

approx. (kg/km)

Copper content approx. (kg/km)

6 3,15 1,0 5,5±0,8 80 54

10 4,05 1,0 6,5±0,8 120 87

16 5,15 1,0 7,5±0,8 180 143

25 6,4 1,2 9,5±0,8 280 224

35 7,65 1,2 10,5±1,0 370 310

50 9,00 1,4 12,5±1,0 520 430

70 10,85 1,4 14,5±1,0 730 620

95 12,60 1,6 16,5±1,0 970 840

120 14,20 1,6 18,0±1,0 1220 1080

150 15,90 1,8 20,0±1,5 1520 1342

185 17,70 2,0 22,0±1,5 1890 1670

240 20,15 2,2 25,0±1,5 2450 2183

300 22,60 2,4 28,0±1,5 3090 2762

Installation recommendations: In accordance with IEC 60092-352

Minimum bending radius Maximum pulling tension Minium installation temperature

During installation Fixed installed 25N x total

8 x cable diameter

6 x cable diameter

cross section of conductors - 20 °C

Ordering information:

Conductor area (mm²)

DRAKA NORSK KABEL Part number Yellow/green

El-number (Norway only)

6 800800 1045541

10 800801 1045542 16 800802 1045543 25 800803 1045553 35 800804 1045563 50 800805 1045573 70 800806 1045583 95 800807 1045593 120 800808 1045603 150 800809 1045604 185 800810 240 800811 300 800812

292

Page 300: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline BI Fire resistant power cable 0.6/1 kV Halogen free shipcable

Page 1 of 3 10-9-2007

BI 0.6/1kVMGT/XLPE/SHF1 Max. conductor temp. : 90°CNominal v oltage : 0.6/1 kV

Application

Unarmoured fire resistant cable for fixed installations on ships where cable protection is not required. For critical power, lighting, control, alarm and emergency systems. Can be installed and operated both indoors and

utdoors. o

Standards applied Design - IEC 60092-353 Conductor - IEC 60228 class 2 Insulation - IEC 60092-351 Sheath - IEC 60092-359 Fire retardant - IEC 60332-3-22 (cat. A)Fire resistant - IEC 60331-21 Halogen Free - IEC 60754-1,2 Low smoke - IEC 61034-1,2

Construction

CODE

LETTER

Conductor Annealed stranded copper, 3- and 4-core cables >= 35 mm2 sector shaped conductors, other types circular conductors

Insulation B Mica glass tape and crosslinked polyethylene, XLPE

Lay up Over the laid up cores one or more tapes may be applied

Inner covering No inner covering

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Marking text DRAKA factory code BI 0,6/1 kV ..x.. mm2 IEC60331 IEC60332-3-22 ShipLine year of manufacture length indication (meter)

Outer sheath colour

Green

293

Page 301: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline BI Fire resistant power cable 0.6/1 kV Halogen free shipcable

Page 2 of 3 10-9-2007

Core identification Single core Black Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black Multi core White with black numbers with yellow/green (optional) Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey Range and dimensions Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

2 1.5 - 3.3 0.7 - 1.1 8.5 85 27 2 2.5 - 3.8 0.7 - 1.1 9.5 110 45 3 1.5 - 3.3 0.7 - 1.1 9.5 105 39 3 2.5 - 3.8 0.7 - 1.1 10.0 145 68 3 4 - 4.3 0.7 - 1.2 11.5 205 110 4 1.5 - 3.3 0.7 - 1.1 10.0 135 55 4 6 - 4.8 0.7 - 1.2 14.5 350 227 5 1.5 - 3.3 0.7 - 1.1 11.0 170 70 5 2.5 - 3.8 0.7 - 1.2 12.5 240 127

Electrical values Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Conductor type

Resistance at 20 oC

DC (Ohm/km)

Resistance at 90 oC 50 Hz

(Ohm/km)

Reactance at 50Hz

(Ohm/km)

Reactance at 60Hz

(Ohm/km)

Current rating

IEC60092-352 (A)

Short circuit rating 1sec (A)

2 1.5 - 1.83 2.33 0.110 0.132 20 210 2 2.5 - 1.15 1.47 0.103 0.124 26 355 3 1.5 - 0.727 0.927 0.110 0.132 16 210 3 2.5 - 0.524 0.669 0.103 0.124 21 355 3 4 - 0.387 0.494 0.097 0.116 28 570 4 1.5 - 0.268 0.343 0.117 0.141 14 210 4 6 - 0.193 0.248 0.100 0.120 32.5 855 5 1.5 - 0.153 0.198 0.120 0.144 13 210 5 2.5 - 0.124 0.162 0.113 0.136 16.5 210

294

Page 302: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline BI Fire resistant power cable 0.6/1 kV Halogen free shipcable

Page 3 of 3 10-9-2007

Ordering information Part

number Description EAN No.

KDN Stock Item

126458 BI fr 0,6/1kV gn# 2x1,5 mm2 8711401039439 Yes 126461 BI fr 0,6/1kV gn# 2x2,5 mm2 8711401039460 No 126459 BI fr 0,6/1kV gn# 3x1,5 mm2 8711401039446 Yes 126462 BI fr 0,6/1kV gn# 3x2,5 mm2 8711401039477 No 126463 BI fr 0,6/1kV gn# 3x4 mm2 8711401039484 No 126460 BI fr 0,6/1kV gn# 4x1,5 mm2 8711401039453 No 127061 BI fr 0,6/1kV gn# 4x6 mm2 8711401058355 No 128218 BI fr 0,6/1kV gn# 5x1,5 mm2 8711401105233 No 128219 BI fr 0,6/1kV gn# 5x2,5 mm2 8711401105240 No

Ambient temperature correction factors Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75 Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations Minimum bending radius

during installation Minimum bending radius

fixed installed Maximum tensile load

during installation Minimum installation

temperature 8 x D 6 x D 50 N * total cross section

conductors -20 °C

Subject to change without notice

295

Page 303: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline BXOI Fire resistant power cable 0.6/1 kV Halogen free shipcable

Page 1 of 4 10-9-2007

BXOI 0.6/1kVMGT/XLPE/TCWB/SHF1 Max. conductor temp. : 90°CNominal v oltage : 0.6/1 kV

Application

Armoured fire resistant cable for fixed installations on ships where cable protection is required. For critical power, lighting, control, alarm and emergency systems. Can be installed and operated both indoors and

utdoors. o

Standards applied Design - IEC 60092-353 Conductor - IEC 60228 class 2 Insulation - IEC 60092-351 Sheath - IEC 60092-359 Fire retardant - IEC 60332-3-22 (cat. A)Fire resistant - IEC 60331-21 Halogen Free - IEC 60754-1,2 Low smoke - IEC 61034-1,2

Construction

CODE

LETTER

Conductor Annealed stranded copper, 3- and 4-core cables >= 35 mm2 sector shaped conductors, other types circular conductors

Insulation B Mica glass tape and crosslinked polyethylene, XLPE

Lay up Over the laid up cores one or more tapes may be applied

Inner covering X No inner covering

Armour/screen O Tinned copper wire braid

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Marking text DRAKA factory code BXOI 0,6/1 kV ..x../.. mm2 IEC60331-21 IEC60332-3-22 ShipLine year of manufacture length indication (meter)

Outer sheath colour

Green

296

Page 304: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline BXOI Fire resistant power cable 0.6/1 kV Halogen free shipcable

Page 2 of 4 10-9-2007

Core identification Single core Black Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black Multi core White with black numbers with yellow/green (optional) Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey Range and dimensions Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

1 35 4 10.8 0.7 0.2 1.2 13.0 480 367 1 95 6 16.1 0.7 0.2 1.4 19.7 1190 973 1 185 10 22.1 0.7 0.3 1.6 26.5 2290 1963 2 1.5 2.5 3.3 0.7 0.2 1.1 10.0 134 67 2 2.5 2.5 3.8 0.7 0.2 1.1 10.5 170 98 3 1.5 2.5 3.3 0.7 0.2 1.1 10.5 157 80 3 2.5 2.5 3.8 0.7 0.2 1.2 11.0 205 120 3 4 4 4.3 0.7 0.2 1.2 12.5 275 170 3 6 6 4.8 0.7 0.3 1.3 14.5 380 261 3 10 10 5.8 0.7 0.3 1.4 16.8 525 373 3 25 16 9.6 0.9 0.4 1.6 23.0 1150 913 3 35 16 10.8 0.9 0.3 1.7 26.5 1490 1169 3 50 25 12.1 1.0 0.4 1.7 27.0 1930 1563 3 70 35 13.9 1.1 0.6 2.0 30.0 2690 2238 3 95 50 16.1 1.1 0.6 2.2 35.5 3720 3125 5 1.5 4 3.3 0.7 0.2 1.2 12.5 240 1290 7 1.5 6 3.3 0.7 0.2 1.3 13.5 310 1870

12 1.5 6 3.3 0.7 0.3 1.4 18.0 470 2740 19 1.5 6 3.3 0.7 0.3 1.5 21.0 650 3870

297

Page 305: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline BXOI Fire resistant power cable 0.6/1 kV Halogen free shipcable

Page 3 of 4 10-9-2007

Electrical values Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Conductor type

Resistance at 20 oC

DC (Ohm/km)

Resistance at 90 oC 50 Hz

(Ohm/km)

Reactance at 50Hz

(Ohm/km)

Reactance at 60Hz

(Ohm/km)

Current rating

IEC60092-352 (A)

Short circuit rating 1sec (A)

1 35 4 SCC 0.524 0.669 0.098 0.118 157 5005 1 95 6 SCC 0.193 0.248 0.089 0.107 293 13585 1 185 10 SCC 0.0991 0.131 0.087 0.104 444 26455 2 1.5 2.5 SCC 12.1 15.4 0.110 0.132 20 210 2 2.5 2.5 SCC 7.41 9.45 0.103 0.124 26 355 3 1.5 2.5 SCC 12.1 15.4 0.110 0.132 16 210 3 2.5 2.5 SCC 7.41 9.45 0.103 0.124 21 355 3 4 4 SCC 4.61 5.88 0.097 0.116 28 570 3 6 6 SCC 3.08 3.93 0.093 0.111 36 855 3 10 10 SCC 1.83 2.33 0.089 0.107 50 1430 3 25 16 SCC 0.727 0.927 0.091 0.109 89 3575 3 35 16 SCC 0.524 0.669 0.087 0.104 110 5005 3 50 25 SCC 0.387 0.494 0.081 0.098 137 7150 3 70 35 SCC 0.268 0.343 0.078 0.094 169 10010 3 95 50 SCC 0.193 0.248 0.076 0.091 205 13585 5 1.5 4 SCC 12.1 15.4 0.120 0.144 13 210 7 1.5 6 SCC 12.1 15.4 0.120 0.144 12 210

12 1.5 6 SCC 12.1 15.4 0.120 0.144 10 210 19 1.5 6 SCC 12.1 15.4 0.120 0.144 8.5 210

SCC = Stranded Circular Conductor

Ordering information

Part number

Description EAN No. KDN

Stock Item

128147 BXOI fr 0.6/1kV green 1x35/4 mm2 8711401104359 N 128148 BXOI fr 0.6/1kV green 1x95/6 mm2 8711401104366 N 128149 BXOI fr 0.6/1kV green 1x185/10 mm2 8711401104373 N 125758 BXOI fr 0.6/1kV green 2x1,5/2,5 mm2 8711401030856 Y 125764 BXOI fr 0.6/1kV green 2x2,5/2,5 mm2 8711401030900 N 125760 BXOI fr 0.6/1kV green 3x1,5/2,5 mm2 8711401030863 N 125763 BXOI fr 0.6/1kV green 3x2,5/2,5 mm2 8711401030894 N 126457 BXOI fr 0.6/1kV green 3x4/4 mm2 8711401039422 N 126986 BXOI fr 0.6/1kV green 3x6/6 mm2 8711401050229 N 125765 BXOI fr 0.6/1kV green 3x10/10 mm2 8711401030917 N 128142 BXOI fr 0.6/1kV green 3x25/16 mm2 8711401104304 N 128143 BXOI fr 0.6/1kV green 3x35/16 mm2 8711401104311 N 128144 BXOI fr 0.6/1kV green 3x50/25 mm2 8711401104328 N 128145 BXOI fr 0.6/1kV green 3x70/35 mm2 8711401104335 N 128146 BXOI fr 0.6/1kV green 3x95/50 mm2 8711401104342 N 126456 BXOI fr 0.6/1kV green 5x1,5/4 mm2 8711401039415 N 125761 BXOI fr 0.6/1kV green 7x1,5/6 mm2 8711401030870 N 125762 BXOI fr 0.6/1kV green 12x1,5/6 mm2 8711401030887 N 128220 BXOI fr 0.6/1kV green 19x1,5/6 mm2 8711401105257 N

298

Page 306: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline BXOI Fire resistant power cable 0.6/1 kV Halogen free shipcable

Page 4 of 4 10-9-2007

Ambient temperature correction factors Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75 Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations Minimum bending radius

during installation Minimum bending radius

fixed installed Maximum tensile load

during installation Minimum installation

temperature 8 x D 6 x D 50 N * total cross section

conductors -20 °C

Subject to change without notice

299

Page 307: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline BXOI Fire resistant instrument cable 250V Halogen free shipcable

Page 1 of 3 10-9-2007

BXOI 250VMGT/XLPE/TCWB/SHF1 Max. conductor temp. : 90°CNominal v oltage : 250V

Application

Armoured fire resistant cable for fixed installations on ships where cable protection is required. For critical control, alarm and emergency systems.Can be installed and operated both indoors and

utdoors. o

Standards applied Design - IEC 60092-353 Conductor - IEC 60228 class 2 Insulation - IEC 60092-351 Sheath - IEC 60092-359 Fire retardant - IEC 60332-3-22 (cat. A)Fire resistant - IEC 60331-21 Halogen Free - IEC 60754-1,2 Low smoke - IEC 61034-1,2

Construction

CODE

LETTER

Conductor Annealed stranded circular copper conductors

Insulation B Mica glass tape and crosslinked polyethylene, XLPE

Lay up Numbered white cores twisted in pairs (two pair type may be built up

as a star quad). The pairs are twisted with different lay length to reduce mutual capacitance. Over the laid up cores one or more tapes may be applied

Inner covering X No inner covering

Armour/screen O Tinned copper wire braid

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Marking text DRAKA factory code BXOI 250 V .. pair/triple/quad .. mm2 IEC60092-376 IEC60331 IEC60332-3-22 ShipLine year of manufacture length indication (meter)

Outer sheath colour

Green

300

Page 308: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline BXOI Fire resistant instrument cable 250V Halogen free shipcable

Page 2 of 3 10-9-2007

Identification of elements White cores with black numbers The pairs have the following number identification according to IEC 60092-376 Pair no. 1 core no. 1 and 2Pair no. 2 core no. 3 and 4Pair no. 3 core no. 5 and 6Pair no. 4 etc. The single triple is identified with no 1, 2 and 3 1 The single quad cable has thefollowing identification

4 + 3 2

Range and dimensions

Elements (pair) (triple) (quad)

Conductor cross

section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

1 pair 0.75 - 2.35 0.7 0.2 1.0 8.5 95 44 1 pair 1.5 - 2.85 0.7 0.2 1.0 9.5 115 73 2 pair 0.75 - 2.35 0.7 0.2 1.2 13.0 170 73 4 pair 0.75 - 2.35 0.7 0.2 1.2 15.5 240 108 7 pair 0.75 - 2.35 0.7 0.3 1.3 18.5 390 198 10 pair 0.75 - 2.35 0.7 0.3 1.5 23.5 550 265

Electrical values Type Capacitance

approx. (nF/km)

Inductance Approx. (mH/km)

Resistance at 20 oC

(Ohm/km) Unshielded pair/quad 0.75 mm2 55 0.75 24.8 Unshielded pair/quad 1.5 mm2 65 0.67 12.2

301

Page 309: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline BXOI Fire resistant instrument cable 250V Halogen free shipcable

Page 3 of 3 10-9-2007

Ordering information Part

number Description EAN No.

KDN Stock Item

125560 BXOI fr 250V gn# 1x2x0,75 mm2 8711401030931 No 127041 BXOI fr 250V gn# 1x2x1,5 mm2 8711401058065 No 125766 BXOI fr 250V gn# 2x2x0,75 mm2 8711401030924 No 127139 BXOI fr 250V gn# 4x2x0,75 mm2 8711401062147 No 125767 BXOI fr 250V gn# 7x2x0,75 mm2 8711401030955 No 125840 BXOI fr 250V gn# 10x2x0,75 mm2 8711401031655 No

Ambient temperature correction factors Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75 Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations Minimum bending radius

during installation Minimum bending radius

fixed installed Maximum tensile load

during installation Minimum installation

temperature 8 x D 6 x D 50 N * total cross section

conductors -20 °C

Subject to change without notice

302

Page 310: Prysmian Draka - Marine & Offshore LV HV Cables

TFOI 12kV(2).doc 21.06.2006 14:02

Page 1 of 2

Shipline TFOI 6/10(12)kV MV Power cable

Flame retardant halogen-free medium voltage (MV) power cable. Braided

TFOI 6/10(12) kVXLPE/EPR/TCWB/PO

Operating temperature : 90°COperating Voltage : 6/10(12) kV

Application

Armoured cable for fixed installation in ships where cable protection is required. Medium Voltage power distribution. Can be

d and operated both indoors and outdoors. installe

Standards applied

IEC 60092-354 - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Annealed stranded circular copper, IEC 60228 class 2 Conductor screen semiconductive

Extruded semiconductive layer

Insulation T Crosslinked Polyethylene, IEC 60092-351 (HFXLPE) Insulation screen semicoductive

Extruded semiconductive layer. A copper tape is applied as a metallic screen above the insulation screen. The thickness of the copper tape is 0,1 mm.

Lay up / Shielding Cores are laid up together. Cores are identified by White, Black or Red threads under and over the metallic screen on each conductor.

Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over bedding Additional tape may be applied Armour/screen O Tinned copper wire braid Tape over armour/screen

Additional tape may be applied

Outer sheath I Flame retardant halogen-free thermoplastic compound, SHF1 Marking text

E.g. "meter" "year" DRAKA NORSK KABEL TFOI 6/10(12)KV 3 x 95/50 mm2 IEC 60332-3-22 ShipLine

Outer sheath colour Red

www.drakaMOG.com Subject to change without prior notice

303

Page 311: Prysmian Draka - Marine & Offshore LV HV Cables

TFOI 12kV(2).doc 21.06.2006 14:02

Page 2 of 2

Shipline TFOI 6/10(12)kV MV Power cable

Range and dimensions

Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Bedding, mm

Diameter bedding, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 95 10 11.2 3.4 1 22.5 ± 1 0.3 1.7 27 ± 1 1640 1094

1 150 10 14.2 3.4 1 26 ± 1 0.3 1.8 30.5 ± 1.5 2220 1542

3 95 50 11.2 3.4 1.8 48.5 ± 2 0.5 2.6 55.5 ± 2.5 6060 3390

3 120 60 12.6 3.4 1.8 52.5 ± 2.5 0.6 2.7 60 ± 3 7270 4291

Ordering information Part number Description EAN No. DNK EL No. KDN Part number EAN no. KDN

838504 TFOI 6/10(12)KV 1X 95/10mm2 7021528385045 - - - 838506 TFOI 6/10(12)KV 1X 150/10mm2 7021528385069 - - - 838525 TFOI 6/10(12)kV 3X 95/50mm² 7021528385250 - - - 838526 TFOI 6/10(12)kV 3X 120/60mm² 7021528385267 - - -

Electrical values power cables Number

of elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type 2

Max. conductor resistance at 20°C, Ohm/km

Max. conductor resistance at 90°C, Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Capacitans per phase,

nF/km

Current rating IEC

60092-352,

Ampere

Short circuit

rating 1 second, Ampere

1 95 10 SCC 0.193 0.246 0.119 0.143 300 293 16800 1 150 10 SCC 0.124 0.158 0.113 0.136 360 389 21000 3 95 50 SCC 0.193 0.246 0.091 0.109 300 205 4900 3 120 60 SCC 0.153 0.195 0.088 0.106 330 237 9800

Ambient temperature correction factors Ambient Temp °C 35 40 45 50 55 60 65 70 75 80 Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 15 x D 9 x D 50 N /mm² -10°C

www.drakaMOG.com Subject to change without prior notice

304

Page 312: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TI Power cable 0.6/1 kV Halogen free shipcable

Page 1 of 6 10-9-2007

TI 0.6/1kVXLPE/SHF1 Max. conductor temp. : 90°CNominal v oltage : 0.6/1 kV

Application

Unarmoured cable for fixed installations on ships where cable protection is not required. For power, control and lighting systems. Can be installed and operated both indoors and

utdoors. o

Standards applied Design - IEC 60092-353 Conductor - IEC 60228 class 2 Insulation - IEC 60092-351 Sheath - IEC 60092-359 Fire retardant - IEC 60332-3-22 (cat. A)Halogen Free - IEC 60754-1,2 Low smoke - IEC 61034-1,2

Construction

CODE

LETTER

Conductor Annealed stranded copper, 3- and 4-core cables >= 35 mm2 sector shaped conductors, other types circular conductors

Insulation T Crosslinked polyethylene, XLPE

Lay up Polyester tape(s) may be applied over the laid up cores

Inner covering No inner covering

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Marking text DRAKA factory code TI 0,6/1 kV ..x.. mm2 IEC60332-3-22 ShipLine year of manufacture length indication (meter)

Outer sheath colour

Black

305

Page 313: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TI Power cable 0.6/1 kV Halogen free shipcable

Page 2 of 6 10-9-2007

Core identification Single core Black Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black Multi core White with black numbers with yellow/green (optional) Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey Range and dimensions Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

1 10 - 5.4 0.7 - 1.0 7.5 130 85 1 16 - 6.4 0.7 - 1.0 8.5 190 136 1 25 - 8.1 0.9 - 1.1 10.4 295 217 1 35 - 9.4 0.9 - 1.1 11.7 380 300 1 50 - 10.8 1.0 - 1.2 13.3 510 405 1 70 - 12.8 1.1 - 1.3 15.5 720 587 1 95 - 14.7 1.1 - 1.3 17.4 970 819 1 120 - 16.5 1.2 - 1.4 19.4 1220 1040 1 150 - 18.4 1.4 - 1.5 21.5 1505 1282 1 185 - 20.7 1.6 - 1.5 23.8 1865 1606 1 240 - 23.4 1.7 - 1.6 26.7 2420 2108 1 300 - 26.0 1.8 - 1.7 29.6 3015 2642 2 1.5 - 3.0 0.7 - 1.1 8.4 80 26 2 1.5 - 3.0 0.7 - 1.1 8.4 80 26 2 2.5 - 3.5 0.7 - 1.1 9.2 100 42 2 4 - 4.0 0.7 - 1.1 10.3 135 69 2 6 - 4.5 0.7 - 1.2 11.6 185 102 2 10 - 5.4 0.7 - 1.2 13.3 270 170 2 16 - 6.4 0.7 - 1.3 15.6 400 273

3G 1.5 - 3.0 0.7 - 1.1 8.8 100 39 3G 2.5 - 3.5 0.7 - 1.1 9.8 130 64 3G 4 - 4.0 0.7 - 1.2 11.1 190 104 3G 6 - 4.5 0.7 - 1.2 12.3 250 153 3G 16 - 6.4 0.7 - 1.3 16.6 560 410 3 1.5 - 3.0 0.7 - 1.1 8.8 100 39 3 2.5 - 3.5 0.7 - 1.1 9.8 130 64 3 4 - 4.0 0.7 - 1.2 11.1 190 104 3 6 - 4.5 0.7 - 1.2 12.3 250 153 3 10 - 5.4 0.7 - 1.3 14.3 380 56 3 16 - 6.4 0.7 - 1.3 16.6 560 410 3 25 - 8.1 0.9 - 1.5 20.7 875 655

306

Page 314: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TI Power cable 0.6/1 kV Halogen free shipcable

Page 3 of 6 10-9-2007

Conductors Conductor cross

section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

3 35 - 9.4 0.9 - 1.6 23.5 1220 904 3 35 - 7.8/12.4 0.9 - 1.5 20.1 1135 917 3 50 - 8.9/14.2 1.0 - 1.7 22.8 1530 1251 3 70 - 10.5/16.9 1.1 - 1.8 26.7 2150 1802 3 95 - 12.1/19.7 1.1 - 1.9 30.2 2900 2470 3 120 - 13.5/21.9 1.2 - 2.1 34.0 3675 3152

4G 1.5 - 3.0 0.7 - 1.1 9.6 120 52 4G 2.5 - 3.5 0.7 - 1.1 10.7 165 85 4G 4 - 4.0 0.7 - 1.2 12.2 240 138 4G 6 - 4.5 0.7 - 1. 13.5 320 204 4G 10 - 5.4 0.7 - 1.3 15.7 490 342 4G 16 - 6.4 0.7 - 1.4 18.5 740 548 4G 4G

25 35

- -

8.1 9.4

0.9 0.9

- -

1.5 1.7

22.8 26.0

1145 1515

874 1207

4 1.5 - 3.0 0.7 - 1.1 9.6 120 52 4 2.5 - 3.5 0.7 - 1.1 10.7 165 85 4 4 - 4.0 0.7 - 1.2 12.2 240 138 4 6 - 4.5 0.7 - 1.2 13.5 320 204 4 10 - 5.4 0.7 - 1.3 15.7 490 342 4 16 - 6.4 0.7 - 1.4 18.5 740 548 4 25 - 8.1 0.9 - 1.5 22.8 1145 874

5G 1.5 - 3.0 0.7 - 1.1 10.5 145 66 5G 2.5 - 3.5 0.7 - 1.2 11.9 205 106 5G 6 - 4.5 0.7 - 1.3 15.0 400 255 5G 16 - 6.4 0.7 - 1.5 20.5 920 686 5 1.5 - 3.0 0.7 - 1.1 10.5 145 66 5 2.5 - 3.5 0.7 - 1.2 11.9 205 106 6 1.5 - 3.0 0.7 - 1.2 11.6 180 80 7 1.5 - 3.0 0.7 - 1.2 11.7 195 93

8G 1.5 - 3.0 0.7 - 1.2 12.7 225 106 8 1.5 - 3.0 0.7 - 1.2 12.7 225 106

10 1.5 - 3.0 0.7 - 1.3 14.8 275 133 12 1.5 - 3.0 0.7 - 1.3 15.3 315 160 16 1.5 - 3.0 0.7 - 1.4 17.2 410 213 19 1.5 - 3.0 0.7 - 1.4 18.1 470 253 24 1.5 - 3.0 0.7 - 1.5 21.3 620 320

307

Page 315: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TI Power cable 0.6/1 kV Halogen free shipcable

Page 4 of 6 10-9-2007

Electrical values Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Conductor type

Resistance at 20 oC

DC (Ohm/km)

Resistance at 90 oC 50 Hz

(Ohm/km)

Reactance at 50Hz

(Ohm/km)

Reactance at 60Hz

(Ohm/km)

Current rating

IEC60092-352 (A)

Short circuit rating 1sec (A)

1 10 - SCC 1.83 2.33 0.105 0.126 72 1430 1 16 - SCC 1.15 1.47 0.098 0.118 96 2285 1 25 - SCC 0.727 0.927 0.096 0.115 127 3575 1 35 - SCC 0.524 0.669 0.091 0.110 157 5005 1 50 - SCC 0.387 0.494 0.087 0.105 196 7150 1 70 - SCC 0.268 0.343 0.085 0.102 242 10010 1 95 - SCC 0.193 0.248 0.082 0.098 293 13585 1 120 - SCC 0.153 0.198 0.081 0.097 339 17160 1 150 - SCC 0.124 0.162 0.081 0.097 389 21450 1 185 - SCC 0.0991 0.131 0.080 0.096 444 26455 1 240 - SCC 0.0754 0.102 0.079 0.094 522 34320 1 300 - SCC 0.0601 0.0831 0.078 0.093 601 42900 2 1.5 - SCC 12.1 15.4 0.104 0.125 20 210 2 1.5 - SCC 12.1 15.4 0.104 0.125 20 210 2 2.5 - SCC 7.41 9.45 0.098 0.118 26 355 2 4 - SCC 4.61 5.88 0.092 0.110 34 570 2 6 - SCC 3.08 3.93 0.088 0.106 44 855 2 10 - SCC 1.83 2.33 0.084 0.101 61 1430 2 16 - SCC 1.15 1.47 0.080 0.096 82 2285

3G 1.5 - SCC 12.1 15.4 0.104 0.125 20 210 3G 2.5 - SCC 7.41 9.45 0.098 0.118 26 355 3G 4 - SCC 4.61 5.88 0.092 0.110 34 570 3G 6 - SCC 3.08 3.93 0.088 0.106 44 855 3G 16 - SCC 1.15 1.47 0.080 0.096 82 2285 3 1.5 - SCC 12.1 15.4 0.104 0.125 16 210 3 2.5 - SCC 7.41 9.45 0.098 0.118 21 355 3 4 - SCC 4.61 5.88 0.092 0.110 28 570 3 6 - SCC 3.08 3.93 0.088 0.106 36 855 3 10 - SCC 1.83 2.33 0.084 0.100 50 1430 3 16 - SCC 1.15 1.47 0.080 0.096 67 2285 3 25 - SCC 0.727 0.927 0.080 0.097 89 3575 3 35 - SCC 0.524 0.669 0.078 0.093 110 5005 3 35 - SSC 0.524 0.669 0.074 0.089 110 5005 3 50 - SSC 0.387 0.494 0.071 0.085 137 7150 3 70 - SSC 0.268 0.343 0.070 0.084 169 10010 3 95 - SSC 0.193 0.248 0.069 0.083 205 13585 3 120 - SSC 0.153 0.198 0.068 0.082 237 17160

4G 1.5 - SCC 12.1 15.4 0.112 0.134 16 210 4G 2.5 - SCC 7.41 9.45 0.105 0.126 21 355 4G 4 - SCC 4.61 5.88 0.099 0.119 28 570 4G 6 - SCC 3.08 3.93 0.095 0.114 36 855 4G 10 - SCC 1.83 2.33 0.091 0.109 50 1430 4G 16 - SCC 1.15 1.47 0.087 0.105 67 2285 4G 4G

25 35

- -

SCC SCC

0.727 0.524

0.927 0.669

0.088 0.088

0.105 0.105

89 110

3575 5005

4 1.5 - SCC 12.1 15.4 0.112 0.134 14 210 4 2.5 - SCC 7.41 9.45 0.105 0.126 18 355 4 4 - SCC 4.61 5.88 0.099 0.119 25 570 4 6 - SCC 3.08 3.93 0.095 0.114 32.5 855

308

Page 316: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TI Power cable 0.6/1 kV Halogen free shipcable

Page 5 of 6 10-9-2007

Conductors Conductor cross

section (mm2)

Screen cross

section (mm2)

Conductor type

Resistance at 20 oC

DC (Ohm/km)

Resistance at 90 oC 50 Hz

(Ohm/km)

Reactance at 50Hz

(Ohm/km)

Reactance at 60Hz

(Ohm/km)

Current rating

IEC60092-352 (A)

Short circuit rating 1sec (A)

4 10 - SCC 1.83 2.33 0.091 0.109 45 1430 4 16 - SCC 1.15 1.47 0.087 0.105 60 2285 4 25 - SCC 0.727 0.927 0.088 0.105 80 3575

5G 1.5 - SCC 12.1 15.4 0.114 0.137 14 210 5G 2.5 - SCC 7.41 9.45 0.108 0.130 18 355 5G 6 - SCC 3.08 3.93 0.098 0.118 32.5 855 5G 16 - SCC 1.15 1.47 0.090 0.108 60 2285 5 1.5 - SCC 12.1 15.4 0.114 0.137 13 210 5 2.5 - SCC 7.41 9.45 0.108 0.130 16.5 355 6 1.5 - SCC 12.1 15.4 0.104 0.125 12.5 210 7 1.5 - SCC 12.1 15.4 0.104 0.125 12 210

8G 1.5 - SCC 12.1 15.4 0.104 0.125 12 210 8 1.5 - SCC 12.1 15.4 0.104 0.125 11.5 210

10 1.5 - SCC 12.1 15.4 0.104 0.125 10.5 210 12 1.5 - SCC 12.1 15.4 0.104 0.125 10 210 16 1.5 - SCC 12.1 15.4 0.104 0.125 9 210 19 1.5 - SCC 12.1 15.4 0.104 0.125 8.5 210 24 1.5 - SCC 12.1 15.4 0.104 0.125 7.5 210

SCC = Stranded Circular Conductor SSC = Stranded Sector Conductor

Ordering information

Part number

Description EAN No. KDN

Stock Item

124831 TI 0,6/1kV black 1x10 mm2 8711401093066 Yes 124832 TI 0,6/1kV black 1x16 mm2 8711401088925 Yes 124833 TI 0,6/1kV black 1x25 mm2 8711401093103 Yes 124834 TI 0,6/1kV black 1x35 mm2 8711401089113 Yes 124835 TI 0,6/1kV black 1x50 mm2 8711401093097 Yes 124836 TI 0,6/1kV black 1x70 mm2 8711401089137 Yes 124837 TI 0,6/1kV black 1x95 mm2 8711401089144 Yes 124838 TI 0,6/1kV black 1x120 mm2 8711401093110 Yes 125521 TI 0,6/1kV black 1x150 mm2 8711401089724 Yes 124839 TI 0,6/1kV black 1x185 mm2 8711401093127 No 124840 TI 0,6/1kV black 1x240 mm2 8711401093134 No 127344 TI 0,6/1kV black 1x300 mm2 8711401093707 No 124841 TI 0,6/1kV black 2x1,5 mm2 8711401093141 Yes 128486 TI 0,6/1kV red 2x1,5 mm2 8711401111784 No 124842 TI 0,6/1kV black 2x2,5 mm2 8711401093165 Yes 124843 TI 0,6/1kV black 2x4 mm2 8711401093172 Yes 124844 TI 0,6/1kV black 2x6 mm2 8711401093189 Yes 124845 TI 0,6/1kV black 2x10 mm2 8711401093196 No 124846 TI 0,6/1kV black 2x16 mm2 8711401093219 Yes 124850 TI 0,6/1kV black 3G1,5 mm2 8711401093233 No 125526 TI 0,6/1kV black 3G2,5 mm2 8711401089175 No 127213 TI 0,6/1kV black 3G4 mm2 8711401093677 No 127215 TI 0,6/1kV black 3G6 mm2 8711401093684 No 127472 TI 0,6/1kV black 3G16 mm2 8711401101433 No 124849 TI 0,6/1kV black 3x1,5 mm2 8711401093226 Yes 124851 TI 0,6/1kV black 3x2,5 mm2 8711401093240 Yes 124852 TI 0,6/1kV black 3x4 mm2 8711401089748 Yes 124853 TI 0,6/1kV black 3x6 mm2 8711401093257 Yes 124854 TI 0,6/1kV black 3x10 mm2 8711401093264 Yes 124855 TI 0,6/1kV black 3x16 mm2 8711401093271 Yes 124856 TI 0,6/1kV black 3x25 mm2 8711401093288 Yes 124857 TI 0,6/1kV black 3x35 mm2 8711401093295 No 125838 TI 0,6/1kV black 3x35 mm2 shaped 8711401093639 No

309

Page 317: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TI Power cable 0.6/1 kV Halogen free shipcable

Page 6 of 6 10-9-2007

Part number

Description EAN No. KDN

Stock Item

124858 TI 0,6/1kV black 3x50 mm2 shaped 8711401093318 Yes 124859 TI 0,6/1kV black 3x70 mm2 shaped 8711401093325 Yes 124860 TI 0,6/1kV black 3x95 mm2 shaped 8711401093332 Yes 124861 TI 0,6/1kV black 3x120 mm2 shaped 8711401093349 No 124864 TI 0,6/1kV black 4G1,5 mm2 8711401089168 No 127212 TI 0,6/1kV black 4G2,5 mm2 8711401093660 No 127214 TI 0,6/1kV black 4G4 mm2 8711401089182 No 127216 TI 0,6/1kV black 4G6 mm2 8711401089199 No 127345 TI 0,6/1kV black 4G10 mm2 8711401093714 No 127416 TI 0,6/1kV black 4G16 mm2 8711401100283 No 127343 TI 0,6/1kV black 4G25 mm2 8711401093691 No 128332 TI 0,6/1kV black 4G35 mm2 8711401106322 No 124863 TI 0,6/1kV black 4x1,5 mm2 8711401093356 Yes 124865 TI 0,6/1kV black 4x2,5 mm2 8711401093370 Yes 124866 TI 0,6/1kV black 4x4 mm2 8711401093387 Yes 124867 TI 0,6/1kV black 4x6 mm2 8711401093394 Yes 124868 TI 0,6/1kV black 4x10 mm2 8711401093424 Yes 124869 TI 0,6/1kV black 4x16 mm2 8711401093431 Yes 127200 TI 0,6/1kV black 4x25 mm2 8711401093653 No 124871 TI 0,6/1kV black 5G1,5 mm2 8711401089731 No 124873 TI 0,6/1kV black 5G2,5 mm2 8711401093509 No 128420 TI 0,6/1kV black 5G6 mm2 8711401107893 No 127997 TI 0,6/1kV black 5G16 mm2 8711401102010 No 124870 TI 0,6/1kV black 5x1,5 mm2 8711401093448 Yes 124872 TI 0,6/1kV black 5x2,5 mm2 8711401093462 Yes 124874 TI 0,6/1kV black 6x1,5 mm2 8711401093516 Yes 124876 TI 0,6/1kV black 7x1,5 mm2 8711401093523 Yes 126447 TI 0,6/1kV black 8G1,5 mm2 8711401093646 No 124877 TI 0,6/1kV black 8x1,5 mm2 8711401093547 Yes 124878 TI 0,6/1kV black 10x1,5 mm2 8711401093561 Yes 124879 TI 0,6/1kV black 12x1,5 mm2 8711401093578 Yes 124880 TI 0,6/1kV black 16x1,5 mm2 8711401093592 Yes 124881 TI 0,6/1kV black 19x1,5 mm2 8711401093615 Yes 124882 TI 0,6/1kV black 24x1,5 mm2 8711401093622 Yes

Ambient temperature correction factors Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75 Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations Minimum bending radius

during installation Minimum bending radius

fixed installed Maximum tensile load

during installation Minimum installation

temperature 8 x D 6 x D 50 N * total cross section

conductors -20 °C

Subject to change without notice

310

Page 318: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TI(c) Control cable 1000V Halogen free shipcable

Page 1 of 3 10-9-2007

TI(c) 0.6/1kVXLPE/OSCR/SHF1 Max. conductor temp. : 90°CNominal voltage : 1000V

Application

Unarmoured cable for fixed installations on ships where cable protection is not required. For control systems. Can be installed and operated both indoors and

utdoors. o

Standards applied Design - IEC 60092-353 Conductor - IEC 60228 class 2 Insulation - IEC 60092-351 Sheath - IEC 60092-359 Fire retardant - IEC 60332-3-22 (cat. A)Halogen Free - IEC 60754-1,2 Low smoke - IEC 61034-1,2

Construction

CODE

LETTER

Conductor Annealed stranded circular copper conductors

Insulation T Crosslinked polyethylene, XLPE

Lay up Over the laid up cores one or more tapes may be applied

Inner covering No inner covering

Shield c Copper backed polyester tape with a tinned copper drain wire of 1,5 mm2

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Marking text DRAKA factory code TI 0,6/1 kV ..x.. mm2 IEC60332-3-22 ShipLine ** year of manufacture length indication (meter)

Outer sheath colour

Black

311

Page 319: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TI(c) Control cable 1000V Halogen free shipcable

Page 2 of 3 10-9-2007

Core identification White cores with black numbers Range and dimensions Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

2 1.5 1.5 3.0 0.7 - 1.1 8.7 95 38 2 2.5 1.5 3.4 0.7 - 1.1 9.6 120 54 3 1.5 1.5 3.0 0.7 - 1.1 9.2 120 51 3 2.5 1.5 3.4 0.7 - 1.1 10.1 155 75 4 1.5 1.5 3.0 0.7 - 1.1 10.0 145 64 5 1.5 1.5 3.0 0.7 - 1.1 10.8 170 77 7 1.5 1.5 3.0 0.7 - 1.2 12.0 215 104

12 1.5 1.5 3.0 0.7 - 1.3 15.6 340 170 19 1.5 1.5 3.0 0.7 - 1.4 18.4 495 262 32 1.5 1.5 3.0 0.7 1.6 23.8 805 434

Electrical values Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Conductor type

Resistance at 20 oC

DC (Ohm/km)

Resistance at 90 oC 50 Hz

(Ohm/km)

Reactance at 50Hz

(Ohm/km)

Reactance at 60Hz

(Ohm/km)

Current rating

IEC60092-352 (A)

Short circuit rating 1sec (A)

2 1.5 1.5 SCC 12.1 15.4 0.103 0.124 20 210 2 2.5 1.5 SCC 7.41 9.45 0.112 0.135 26 355 3 1.5 1.5 SCC 12.1 15.4 0.103 0.124 16 210 3 2.5 1.5 SCC 7.41 9.45 0.112 0.135 21 355 4 1.5 1.5 SCC 12.1 15.4 0.111 0.133 14 210 5 1.5 1.5 SCC 12.1 15.4 0.113 0.136 13 210 7 1.5 1.5 SCC 12.1 15.4 0.103 0.124 12 210

12 1.5 1.5 SCC 12.1 15.4 0.103 0.124 10 210 19 1.5 1.5 SCC 12.1 15.4 0.103 0.124 8.5 210 32 1.5 1.5 SCC 12.1 15.4 0.103 0.124 7.5 210

SCC = Stranded Circular Conductor

312

Page 320: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TI(c) Control cable 1000V Halogen free shipcable

Page 3 of 3 10-9-2007

Ordering information Part

number Description EAN No.

KDN Stock Item

127228 TI(c) 0,6/1kV black 2x1,5 mm2 8711401072900 No 127293 TI(c) 0,6/1kV black 2x2,5 mm2 8711401088222 No 127341 TI(c) 0,6/1kV black 3x1,5 mm2 8711401088499 No 127391 TI(c) 0,6/1kV black 3x2,5 mm2 8711401099433 No 127387 TI(c) 0,6/1kV black 4x1,5 mm2 8711401099037 No 127388 TI(c) 0,6/1kV black 5x1,5 mm2 8711401099051 No 127291 TI(c) 0,6/1kV black 7x1,5 mm2 8711401085528 No 127292 TI(c) 0,6/1kV black 12x1,5 mm2 8711401087768 No 127389 TI(c) 0,6/1kV black 19x1,5 mm2 8711401099730 No 127390 TI(c) 0,6/1kV black 32x1,5 mm2 8711401099761 No

Ambient temperature correction factors Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75 Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations Minimum bending radius

during installation Minimum bending radius

fixed installed Maximum tensile load

during installation Minimum installation

temperature 8 x D 6 x D 50 N * total cross section

conductors -20 °C

Subject to change without notice

313

Page 321: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TXOI Power cable 0.6/1 kV Braided halogen free shipcable

Page 1 of 6 10-9-2007

TXOI 0.6/1kVXLPE/TCWB/SHF1 Max. conductor temp. : 90°CNominal v oltage : 0.6/1 kV

Application

Armoured cable for fixed installations on ships where cable protection is required. For power, control and lighting systems. Can be installed and operated both indoors and

utdoors. o

Standards applied Design - IEC 60092-353 Conductor - IEC 60228 class 2 Insulation - IEC 60092-351 Sheath - IEC 60092-359 Flame retardant - IEC 60332-3-22 (cat. A)Halogen Free - IEC 60754-1,2 Low smoke - IEC 61034-1,2

Construction

CODE

LETTER

Conductor Annealed stranded copper, 3- and 4-core cables >= 35 mm2 sector shaped conductors, other types circular conductors

Insulation T Crosslinked polyethylene, XLPE

Lay up Polyester tape(s) may be applied over the laid up cores

Inner covering X No inner covering

Armour/screen O Tinned copper wire braid

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Marking text DRAKA factory code TXOI 0,6/1 kV ..x../.. mm2 IEC60332-3-22 ShipLine year of manufacture length indication (meter)

Outer sheath colour

Black

314

Page 322: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TXOI Power cable 0.6/1 kV Braided halogen free shipcable

Page 2 of 6 10-9-2007

Core identification Single core Black Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black Multi core White with black numbers with yellow/green (optional) Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey Range and dimensions Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

1 16 2.5 6.4 0.7 0.2 1.1 9.8 245 174 1 25 4 8.1 0.9 0.2 1.2 11.7 355 264 1 35 4 9.4 0.9 0.2 1.2 13.0 455 353 1 50 6 10.8 1.0 0.3 1.3 15.0 620 494 1 70 6 12.8 1.1 0.3 1.4 17.2 850 691 1 95 10 14.7 1.1 0.3 1.4 19.1 1115 936 1 120 10 16.5 1.2 0.3 1.5 21.1 1385 1174 1 150 10 18.4 1.4 0.3 1.6 23.2 1690 1435 1 185 10 20.7 1.6 0.3 1.6 25.5 2065 1769 1 240 10 23.4 1.7 0.3 1.7 28.4 2640 2292 1 300 16 26.0 1.8 0.3 1.8 31.3 3260 2845 2 1.5 2.5 3.0 0.7 0.2 1.1 9.3 120 62 2 2.5 2.5 3.5 0.7 0.2 1.1 10.1 150 83 2 4 4 4.0 0.7 0.2 1.2 11.4 195 115 2 6 6 4.5 0.7 0.3 1.2 12.9 275 180 2 10 10 5.4 0.7 0.3 1.3 14.9 385 267 2 16 16 6.4 0.7 0.3 1.4 17.6 595 445 2 25 16 8.1 0.9 0.4 1.5 21.3 820 614

3G 1.5 2.5 3.0 0.7 0.2 1.1 9.8 145 78 3G 2.5 2.5 3.5 0.7 0.2 1.1 10.7 180 105 3 1.5 2.5 3.0 0.7 0.2 1.1 9.8 145 78 3 2.5 2.5 3.5 0.7 0.2 1.1 10.7 180 105 3 4 4 4.0 0.7 0.2 1.2 12.0 245 151 3 6 6 4.5 0.7 0.3 1.3 13.8 345 233 3 10 10 5.4 0.7 0.3 1.3 15.7 490 352 3 16 16 6.4 0.7 0.4 1.4 18.6 755 582 3 25 16 8.1 0.9 0.4 1.6 22.7 1095 842 3 35 16 9.4 0.9 0.3 1.6 24.9 1340 1073 3 50 25 8.9/14.3 1.0 0.4 1.6 24.8 1820 1508 3 70 35 10.5/16.9 1.1 0.6 2.0 29.7 2575 2161 3 95 50 12.1/19.7 1.1 0.6 2.1 33.1 3435 2943

315

Page 323: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TXOI Power cable 0.6/1 kV Braided halogen free shipcable

Page 3 of 6 10-9-2007

Conductors Conductor cross

section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

3 120 25 13.5/21.9 1.2 0.4 2.2 36.0 4070 3500 3 120 60 13.5/21.9 1.2 0.4 2.3 37.8 4470 3863 3 150 25 15.2/24.7 1.4 0.4 2.3 39.1 4945 4269 3 150 70 15.2/24.7 1.4 0.4 2.4 40.9 5435 4722

4G 1.5 2.5 3.0 0.7 0.2 1.1 10.5 170 93 4G 2.5 2.5 3.5 0.7 0.2 1.2 11.8 225 131 4 1.5 2.5 3.0 0.7 0.2 1.1 10.5 170 93 4 2.5 2.5 3.5 0.7 0.2 1.2 11.8 225 131 4 4 4 4.0 0.7 0.3 1.3 13.7 335 217 4 6 6 4.5 0.7 0.3 1.3 15.0 425 293 4 10 10 5.4 0.7 0.3 1.4 17.3 625 455 4 16 16 6.4 0.7 0.4 1.5 20.5 935 719 4 25 16 8.1 0.9 0.3 1.6 24.4 1345 1043 4 35 16 9.4 0.9 0.3 1.7 27.5 1715 1384 4 70 35 11.5/15.5 1.1 0.4 2.1 32.8 3250 2746 4 95 50 13.3/18.0 1.1 0.6 2.2 37.3 4390 3783 5 1.5 2.5 3.0 0.7 0.2 1.2 11.7 205 111 5 2.5 4 3.5 0.7 0.2 1.2 12.8 265 158 6 1.5 4 3.0 0.7 0.2 1.2 12.7 240 132 7 1.5 4 3.0 0.7 0.2 1.2 12.7 260 145 8 1.5 6 3.0 0.7 0.2 1.2 15.5 340 209

10 1.5 6 3.0 0.7 0.3 1.3 16.2 390 231 12 1.5 6 3.0 0.7 0.3 1.4 16.9 440 261 16 1.5 6 3.0 0.7 0.3 1.4 18.6 550 334 19 1.5 6 3.0 0.7 0.3 1.5 19.7 620 376 24 1.5 10 3.0 0.7 0.3 1.6 22.9 800 468

Electrical values Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Conductor type

Resistance at 20 oC

DC (Ohm/km)

Resistance at 90 oC 50 Hz

(Ohm/km)

Reactance at 50Hz

(Ohm/km)

Reactance at 60Hz

(Ohm/km)

Current rating

IEC60092-352 (A)

Short circuit rating 1sec (A)

1 16 2.5 SCC 1.15 1.47 0.107 0.128 96 2285 1 25 4 SCC 0.727 0.927 0.103 0.124 127 3575 1 35 4 SCC 0.524 0.669 0.098 0.118 157 5005 1 50 6 SCC 0.387 0.494 0.095 0.114 196 7150 1 70 6 SCC 0.268 0.343 0.092 0110 242 10010 1 95 10 SCC 0.193 0.248 0.088 0.106 293 13585 1 120 10 SCC 0.153 0.198 0.086 0.103 339 17160 1 150 10 SCC 0.124 0.162 0.085 0.103 389 21450 1 185 10 SCC 0.0991 0.131 0.085 0.101 444 26455 1 240 10 SCC 0.0754 0.102 0.082 0.099 522 34320 1 300 16 SCC 0.0601 0.0831 0.081 0.098 601 42900 2 1.5 2.5 SCC 12.1 15.4 0.104 0.125 20 210 2 2.5 2.5 SCC 7.41 9.45 0.098 0.118 26 355 2 4 4 SCC 4.61 5.88 0.092 0.110 34 570 2 6 6 SCC 3.08 3.93 0.088 0.106 44 855 2 10 10 SCC 1.83 2.33 0.084 0.100 61 1430 2 16 16 SCC 1.15 1.47 0.080 0.096 82 2285

316

Page 324: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TXOI Power cable 0.6/1 kV Braided halogen free shipcable

Page 4 of 6 10-9-2007

Conductors Conductor cross

section (mm2)

Screen cross

section (mm2)

Conductor type

Resistance at 20 oC

DC (Ohm/km)

Resistance at 90 oC 50 Hz

(Ohm/km)

Reactance at 50Hz

(Ohm/km)

Reactance at 60Hz

(Ohm/km)

Current rating

IEC60092-352 (A)

Short circuit rating 1sec (A)

2 25 16 SCC 0.727 0.927 0.080 0.097 108 3575 3G 1.5 2.5 SCC 12.1 15.4 0.104 0.125 20 210 3G 2.5 2.5 SCC 7.41 9.45 0.098 0.118 26 355 3 1.5 2.5 SCC 12.1 15.4 0.104 0.125 16 210 3 2.5 2.5 SCC 7.41 9.45 0.098 0.118 21 355 3 4 4 SCC 4.61 5.88 0.092 0.110 28 570 3 6 6 SCC 3.08 3.93 0.088 0.106 36 855 3 10 10 SCC 1.83 2.33 0.084 0.100 50 1430 3 16 16 SCC 1.15 1.47 0.080 0.096 67 2285 3 25 16 SCC 0.727 0.927 0.080 0.097 89 3575 3 35 16 SCC 0.524 0.669 0.078 0.093 110 5005 3 50 25 SSC 0.387 0.494 0.071 0.085 137 7150 3 70 35 SSC 0.268 0.343 0.070 0.084 169 10010 3 95 50 SSC 0.193 0.248 0.069 0.083 205 13585 3 120 25 SSC 0.153 0.198 0.068 0.082 237 17160 3 120 60 SSC 0.153 0.198 0.068 0.082 237 17160 3 150 25 SSC 0.124 0.162 0.068 0.082 272 21450 3 150 70 SSC 0.124 0.162 0.068 0.082 272 21450

4G 1.5 2.5 SCC 12.1 15.4 0.112 0.134 16 210 4G 2.5 2.5 SCC 7.41 9.45 0.105 0.126 21 355 4 1.5 2.5 SCC 12.1 15.4 0.112 0.134 14 210 4 2.5 2.5 SCC 7.41 9.45 0.105 0.126 18 355 4 4 4 SCC 4.61 5.88 0.099 0.119 25 570 4 6 6 SCC 3.08 3.93 0.095 0.114 32.5 855 4 10 10 SCC 1.83 2.33 0.091 0.109 45 1430 4 16 16 SCC 1.15 1.47 0.087 0.105 60 2285 4 25 16 SCC 0.727 0.927 0.088 0.105 80 3575 4 35 16 SCC 0.524 0.669 0.085 0.102 98.5 5005 4 70 35 SSC 0.268 0.343 0.079 0.094 152 10010 4 95 50 SSC 0.193 0.248 0.077 0.093 184.5 13585 5 1.5 2.5 SCC 12.1 15.4 0.114 0.137 13 210 5 2.5 4 SCC 7.41 9.45 0.122 0.147 16.5 355 6 1.5 4 SCC 12.1 15.4 0.104 0.125 12.5 210 7 1.5 4 SCC 12.1 15.4 0.104 0.125 12 210 8 1.5 6 SCC 12.1 15.4 0.104 0.125 11.5 210

10 1.5 6 SCC 12.1 15.4 0.104 0.125 10.5 210 12 1.5 6 SCC 12.1 15.4 0.104 0.125 10 210 16 1.5 6 SCC 12.1 15.4 0.104 0.125 9 210 19 1.5 6 SCC 12.1 15.4 0.104 0.125 8.5 210 24 1.5 10 SCC 12.1 15.4 0.104 0.125 7.5 210

SCC = Stranded Circular Conductor SSC = Stranded Sector Conductor

317

Page 325: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TXOI Power cable 0.6/1 kV Braided halogen free shipcable

Page 5 of 6 10-9-2007

Ordering information

Part number

Description EAN No. KDN

Stock Item

124884 TXOI 0,6/1kV black 1x16/2,5 mm2 8711401093745 No 124885 TXOI 0,6/1kV black 1x25/4 mm2 8711401093752 No 124886 TXOI 0,6/1kV black 1x35/4 mm2 8711401089212 No 124887 TXOI 0,6/1kV black 1x50/6 mm2 8711401093783 No 124888 TXOI 0,6/1kV black 1x70/6 mm2 8711401089236 No 124889 TXOI 0,6/1kV black 1x95/10 mm2 8711401093790 No 124890 TXOI 0,6/1kV black 1x120/10 mm2 8711401093813 No 124891 TXOI 0,6/1kV black 1x150/10 mm2 8711401088659 No 124892 TXOI 0,6/1kV black 1x185/10 mm2 8711401093820 No 124893 TXOI 0,6/1kV black 1x240/10 mm2 8711401093837 No 128768 TXOI 0,6/1kV black 1x300/16 mm2 8711401122445 No 124894 TXOI 0,6/1kV black 2x1,5/2,5 mm2 8711401093844 Yes 124895 TXOI 0,6/1kV black 2x2,5/2,5 mm2 8711401093851 Yes 124896 TXOI 0,6/1kV black 2x4/4 mm2 8711401093875 Yes 124897 TXOI 0,6/1kV black 2x6/6 mm2 8711401093882 No 124898 TXOI 0,6/1kV black 2x10/10 mm2 8711401093899 No 124899 TXOI 0,6/1kV black 2x16/16 mm2 8711401093950 No 128004 TXOI 0,6/1kV black 2x25/16 mm2 8711401102133 No 127202 TXOI 0,6/1kV black 3G1,5/2,5 mm2 8711401094421 No 127198 TXOI 0,6/1kV black 3G2,5/2,5 mm2 8711401088666 No 124900 TXOI 0,6/1kV black 3x1,5/2,5 mm2 8711401089311 Yes 124901 TXOI 0,6/1kV black 3x2,5/2,5 mm2 8711401093967 Yes 124902 TXOI 0,6/1kV black 3x4/4 mm2 8711401089410 No 124903 TXOI 0,6/1kV black 3x6/6 mm2 8711401093974 Yes 124904 TXOI 0,6/1kV black 3x10/10 mm2 8711401093981 No 124905 TXOI 0,6/1kV black 3x16/16 mm2 8711401088673 Yes 124906 TXOI 0,6/1kV black 3x25/16 mm2 8711401089717 Yes 124907 TXOI 0,6/1kV black 3x35/16 mm2 8711401094018 Yes 124908 TXOI 0,6/1kV black 3x50/25 mm2 shaped 8711401088680 Yes 124909 TXOI 0,6/1kV black 3x70/35 mm2 shaped 8711401094230 Yes 124910 TXOI 0,6/1kV black 3x95/50 mm2 shaped 8711401088697 No 127205 TXOI 0,6/1kV black 3x120/25 mm2 shaped 8711401094452 No 128399 TXOI 0,6/1kV black 3x120/60 mm2 shaped 8711401107626 No 127347 TXOI 0,6/1kV black 3x150/25 mm2 shaped 8711401093035 No 128400 TXOI 0,6/1kV black 3x150/70 mm2 shaped 8711401107633 No 127203 TXOI 0,6/1kV black 4G1,5/2,5 mm2 8711401094445 No 127199 TXOI 0,6/1kV black 4G2,5/2,5 mm2 8711401094414 No 124913 TXOI 0,6/1kV black 4x1,5/2,5 mm2 8711401089373 Yes 124914 TXOI 0,6/1kV black 4x2,5/2,5 mm2 8711401094247 Yes 124915 TXOI 0,6/1kV black 4x4/6 mm2 8711401094254 Yes 124916 TXOI 0,6/1kV black 4x6/6 mm2 8711401094261 Yes 124917 TXOI 0,6/1kV black 4x10/10 mm2 8711401094278 Yes 124918 TXOI 0,6/1kV black 4x16/16 mm2 8711401094285 Yes 124919 TXOI 0,6/1kV black 4x25/16 mm2 8711401094292 No 127411 TXOI 0,6/1kV black 4x35/16 mm2 8711401100160 No 128334 TXOI 0,6/1kV black 4x70/35 mm2 shaped 8711401106339 No 127346 TXOI 0,6/1kV black 4x95/50 mm2 shaped 8711401089830 No 124920 TXOI 0,6/1kV black 5x1,5/2,5 mm2 8711401094308 Yes 124921 TXOI 0,6/1kV black 5x2,5/4 mm2 8711401094339 No 126759 TXOI 0,6/1kV black 6x1,5/4 mm2 8711401045935 No 124924 TXOI 0,6/1kV black 7x1,5/4 mm2 8711401089380 Yes 126760 TXOI 0,6/1kV black 8x1,5/6 mm2 8711401045942 No 124926 TXOI 0,6/1kV black 10x1,5/6 mm2 8711401094346 Yes 124927 TXOI 0,6/1kV black 12x1,5/6 mm2 8711401094353 Yes 124928 TXOI 0,6/1kV black 16x1,5/6 mm2 8711401094377 No 124929 TXOI 0,6/1kV black 19x1,5/6 mm2 8711401094391 Yes 124930 TXOI 0,6/1kV black 24x1,5/10 mm2 8711401094407 No

318

Page 326: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TXOI Power cable 0.6/1 kV Braided halogen free shipcable

Page 6 of 6 10-9-2007

Ambient temperature correction factors Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75 Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations

Minimum bending radius during installation

Minimum bending radius fixed installed

Maximum tensile load during installation

Minimum installation temperature

8 x D 6 x D 50 N * total cross section conductors

-20 °C

Subject to change without notice

319

Page 327: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TXOI Instrumentation cable 250V Braided halogen free shipcable

Page 1 of 3 10-9-2007

TXOI 250VXLPE/TCWB/SHF1 Max. conductor temp. : 90°CNominal v oltage : 250V

Application

Armoured cable for fixed installations on ships where cable protection is required. For instrumentation and communication systems. Can be installed and operated both indoors and

utdoors. o

Standards applied Design - IEC 60092-376 Conductor - IEC 60228 class 2 Insulation - IEC 60092-351 Sheath - IEC 60092-359 Flame retardant - IEC 60332-3-22 (cat A)Halogen Free - IEC 60754-1,2 Low smoke - IEC 61034-1,2

Construction

CODE

LETTER

Conductor Annealed stranded circular copper conductors

Insulation T Crosslinked polyethylene, XLPE

Lay up Numbered white cores twisted in pairs (two pair type may be built up

as a star quad). The pairs are twisted with different lay length to reduce mutual capacitance. Over the laid up cores one or more tapes may be applied

Inner covering X No inner covering

Armour/screen O Tinned copper wire braid

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Marking text DRAKA factory code TXOI 250 V .. pair/triple/quad .. mm2 IEC60092-376 IEC60332-3-22 ShipLine year of manufacture length indication (meter)

Outer sheath colour

Grey

320

Page 328: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TXOI Instrumentation cable 250V Braided halogen free shipcable

Page 2 of 3 10-9-2007

Identification of elements White cores with black numbers The pairs have the following number identification according to IEC 60092-376 Pair no. 1 core no. 1 and 2Pair no. 2 core no. 3 and 4Pair no. 3 core no. 5 and 6Pair no. 4 etc. The single triple is identified with no 1, 2 and 3 1 The single quad cable has thefollowing identification

4 + 3 2 Range and dimensions

Elements (pair) (triple) (quad)

Conductor cross

section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

1 pair 0.5 - 1.8 0.4 0.2 1.0 6.6 65 33 1 quad 0.5 - 1.8 0.4 0.2 1.0 7.3 85 42 1 pair 0.75 - 2.1 0.5 0.2 1.0 9.1 80 41 1 triple 0.75 - 2.1 0.5 0.2 1.0 7.6 90 47 1 quad 0.75 - 2.1 0.5 0.2 1.0 8.2 105 53 4 pair 0.75 - 2.1 0.5 0.2 1.2 12.2 195 100 7 pair 0.75 - 2.1 0.5 0.2 1.2 14.4 270 145 10 pair 0.75 - 2.1 0.5 0.3 1.4 17.8 410 239 14 pair 0.75 - 2.1 0.5 0.3 1.4 19.3 500 291 19 pair 0.75 - 2.1 0.5 0.3 1.5 21.5 630 373 24 pair 0.75 - 2.1 0.5 0.3 1.7 25.2 805 473

Electrical values Type Capacitance

approx. (nF/km)

Inductance Approx. (mH/km)

Resistance at 20 oC

(Ohm/km) Unshielded pair 0.5 mm2 70 0.60 40.4

Unshielded pair 0.75 mm2 65 0.60 26.0

321

Page 329: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline TXOI Instrumentation cable 250V Braided halogen free shipcable

Page 3 of 3 10-9-2007

Ordering information Part

number Description EAN No.

KDN Stock Item

127257 TXOI 250V gy# 1x2x0,5 mm2 s 8711401094636 No 127258 TXOI 250V gy# 1x4x0,5 mm2 s quad 8711401094643 No 124931 TXOI 250V gy# 1x2x0,75 mm2 s 8711401094476 Yes 127243 TXOI 250V gy# 1x3x0,75 mm2 s 8711401072979 No 124933 TXOI 250V gy# 1x4x0,75 mm2 s 8711401094520 Yes 124934 TXOI 250V gy# 4x2x0,75 mm2 s 8711401094537 Yes 124936 TXOI 250V gy# 7x2x0,75 mm2 s 8711401094544 Yes 124937 TXOI 250V gy# 10x2x0,75 mm2 s 8711401094551 Yes 124938 TXOI 250V gy# 14x2x0,75 mm2 s 8711401094568 Yes 124939 TXOI 250V gy# 19x2x0,75 mm2 s 8711401094582 No 124940 TXOI 250V gy# 24x2x0,75 mm2 s 8711401094629 No

Installation recommendations

Minimum bending radius during installation

Minimum bending radius fixed installed

Maximum tensile load during installation

Minimum installation temperature

8 x D 6 x D 50 N * total cross section conductors

-20 °C

Subject to change without notice

322

Page 330: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TFXI Power cable 0.6/1 kV Halogen free shipcable

Page 1 of 6 20-7-2007

TFXI 0.6/1kVXLPE/SHF1 Max. conductor temp. : 90°CNominal v oltage : 0.6/1 kV

Application

Unarmoured cable for fixed installations on ships where cable protection is not required. For power, control and lighting systems. Can be installed and operated both indoors and

utdoors. o

Standards applied Design - IEC 60092-353 Conductor - IEC 60228 class 2 and 5Insulation - IEC 60092-351 Sheath - IEC 60092-359 Fire retardant - IEC 60332-3-22 (cat. A)Halogen Free - IEC 60754-1,2 Low smoke - IEC 61034-1,2

Construction

CODE

LETTER

Conductor Annealed stranded circular copper conductors, stranded acc IEC 60228 class 2 or flexible acc IEC 60228 class 5

Insulation T Crosslinked polyethylene, XLPE

Lay up Cores laid up in one or more layers; in case of cables with more

than 5 cores one or more tapes may be applied over the laid up cores

Inner sheath F Single core cables no inner covering; 2 – 5 core cables bedding of

flame retardant halogen free thermoplastic compound SHF1; cables with more than 5 cores no inner covering

Armour/screen X No armour or screen

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Marking text DRAKA factory code TFXI 0,6/1 kV ..x.. mm2 IEC60332-3-22 ShipLine Plus year of manufacture length indication (meter)

Outer sheath colour

Black

323

Page 331: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TFXI Power cable 0.6/1 kV Halogen free shipcable

Page 2 of 6 20-7-2007

Core identification Single core Black Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black Multi core White with black numbers with yellow/green (optional) Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey Range and dimensions Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

Class 5 1 25 - 8.4 0.9 - 1.1 10.7 285 210 1 35 - 9.95 0.9 - 1.1 12.3 390 303 1 50 - 11.75 1.0 - 1.2 14.3 545 434 1 70 - 13.8 1.1 - 1.3 16.5 750 613 1 120 - 17.4 1.2 - 1.4 20.3 1210 1022 3 25 - 8.4 0.9 - 1.5 21.6 1035 635 3 35 - 9.95 0.9 - 1.6 25.2 1440 916 3 50 - 11.75 1.0 - 1.7 30.5 2100 1308 3 70 - 13.8 1.1 - 1.9 35.3 2885 1850 3 95 - 15.3 1.1 - 2.0 39.1 3715 2452 Class 2

1 10 - 5.4 0.7 - 1.0 7.5 130 85 1 16 - 6.4 0.7 - 1.0 8.5 190 136 1 25 - 8.1 0.9 - 1.1 10.4 295 217 1 35 - 9.4 0.9 - 1.1 11.7 380 300 1 50 - 10.8 1.0 - 1.2 13.3 510 405 1 70 - 12.8 1.1 - 1.3 15.5 720 587 1 95 - 14.7 1.1 - 1.3 17.4 970 819 1 120 - 16.5 1.2 - 1.4 19.4 1220 1040 1 150 - 18.4 1.4 - 1.5 21.5 1505 1282 1 185 - 20.7 1.6 - 1.5 23.8 1865 1606 1 240 - 23.4 1.7 - 1.6 26.7 2420 2108 1 400 - 29.3 2.0 - 1.9 33.3 3850 3384 2 1.5 - 3.0 0.7 - 1.0 8.6 110 26 2 2.5 - 3.5 0.7 - 1.1 9.6 150 42 2 4 - 4.0 0.7 - 1.1 10.7 195 69 2 6 - 4.5 0.7 - 1.2 12.0 260 102 2 10 - 5.4 0.7 - 1.2 13.7 370 170 2 16 - 6.4 0.7 - 1.3 16.0 540 273

324

Page 332: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TFXI Power cable 0.6/1 kV Halogen free shipcable

Page 3 of 6 20-7-2007

Conductors Conductor cross

section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

3G 1.5 - 3.0 0.7 - 1.1 9.2 130 39 3G 2.5 - 3.5 0.7 - 1.1 10.2 175 64 3 1.5 - 3.0 0.7 - 1.1 9.2 130 39 3 2.5 - 3.5 0.7 - 1.1 10.2 175 64 3 4 - 4.0 0.7 - 1.1 11.3 235 104 3 6 - 4.5 0.7 - 1.2 12.7 315 153 3 10 - 5.4 0.7 - 1.3 14.7 465 256 3 16 - 6.4 0.7 - 1.3 17.0 680 410 3 25 - 8.1 0.9 - 1.5 21.1 1060 655 3 35 - 9.4 0.9 - 1.6 23.9 1390 904 3 50 - 10.8 1.0 - 1.7 28.3 1925 1223 3 70 - 12.8 1.1 - 1.9 33.1 2705 1772 3 95 - 14.7 1.1 - 2.0 37.8 3665 2469 3 120 - 16.5 1.2 - 2.2 42.0 4595 3137 3 150 - 18.4 1.4 - 2.3 46.3 5620 3865

4G 1.5 - 3.0 0.7 - 1.1 10.0 155 52 4G 2.5 - 3.5 0.7 - 1.1 11.1 205 85 4G 6 - 4.5 0.7 - 1.2 13.9 385 204 4 1.5 - 3.0 0.7 - 1.1 10.0 155 52 4 2.5 - 3.5 0.7 - 1.1 11.1 205 85 4 4 - 4.0 0.7 - 1.2 12.6 290 138 4 6 - 4.5 0.7 - 1.2 13.9 385 204 4 10 - 5.4 0.7 - 1.3 16.1 575 342 4 16 - 6.4 0.7 - 1.4 18.9 855 548

5G 1.5 - 3.0 0.7 - 1.1 10.9 185 66 5G 2.5 - 3.5 0.7 - 1.2 12.3 250 106 5 1.5 - 3.0 0.7 - 1.1 10.9 185 66 5 2.5 - 3.5 0.7 - 1.2 12.3 250 106 6 1.5 - 3.0 0.7 - 1.2 11.6 180 80 7 1.5 - 3.0 0.7 - 1.2 11.7 195 93

8G 1.5 - 3.0 0.7 - 1.2 12.7 225 106 8 1.5 - 3.0 0.7 - 1.2 12.7 225 106

10 1.5 - 3.0 0.7 - 1.3 14.8 275 133 12 1.5 - 3.0 0.7 - 1.3 15.3 315 160 16 1.5 - 3.0 0.7 - 1.4 17.2 410 213 19 1.5 - 3.0 0.7 - 1.4 18.1 470 253 24 1.5 - 3.0 0.7 - 1.5 21.3 620 320

325

Page 333: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TFXI Power cable 0.6/1 kV Halogen free shipcable

Page 4 of 6 20-7-2007

Electrical values Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Conductor type

Resistance at 20 oC

DC (Ohm/km)

Resistance at 90 oC 50 Hz

(Ohm/km)

Reactance at 50Hz

(Ohm/km)

Reactance at 60Hz

(Ohm/km)

Current rating

IEC60092-352 (A)

Short circuit rating 1sec (A)

Class 5 1 25 - SCC 0.78 0.995 0.094 0.113 127 3575 1 35 - SCC 0.554 0.706 0.090 0.107 157 5005 1 50 - SCC 0.386 0.492 0.085 0.102 196 7150 1 70 - SCC 0.272 0.347 0.083 0.100 242 10010 1 120 - SCC 0.161 0.205 0.079 0.095 339 17160 3 25 - SCC 0.78 0.995 0.079 0.095 89 3575 3 35 - SCC 0.554 0.706 0.076 0.092 110 5005 3 50 - SCC 0.386 0.492 0.073 0.087 137 7150 3 70 - SCC 0.272 0.347 0.072 0.086 169 10010 3 95 - SCC 0.206 0.263 0.071 0.085 205 13585 Class 2

1 10 - SCC 1.83 2.33 0.105 0.126 72 1430 1 16 - SCC 1.15 1.47 0.098 0.118 96 2285 1 25 - SCC 0.727 0.927 0.096 0.115 127 3575 1 35 - SCC 0.524 0.669 0.091 0.110 157 5005 1 50 - SCC 0.387 0.494 0.087 0.105 196 7150 1 70 - SCC 0.268 0.343 0.085 0.102 242 10010 1 95 - SCC 0.193 0.248 0.082 0.098 293 13585 1 120 - SCC 0.153 0.198 0.081 0.097 339 17160 1 150 - SCC 0.124 0.162 0.080 0.097 389 21450 1 185 - SCC 0.0991 0.131 0.080 0.096 444 26455 1 240 - SCC 0.0754 0.102 00.78 0.094 522 34320 1 400 - SCC 0.047 0.0685 0.078 0.093 670 57200 2 1.5 - SCC 12.1 15.4 0.104 0.125 20 210 2 2.5 - SCC 7.41 9.45 0.098 0.118 26 355 2 4 - SCC 4.61 5.88 0.092 0.110 34 570 2 6 - SCC 3.08 3.93 0.088 0.106 44 855 2 10 - SCC 1.83 2.33 0.084 0.100 61 1430 2 16 - SCC 1.15 1.47 0.080 0.096 82 2285

3G 1.5 - SCC 12.1 15.4 0.104 0.125 20 210 3G 2.5 - SCC 7.41 9.45 0.098 0.118 26 355 3 1.5 - SCC 12.1 15.4 0.104 0.125 16 210 3 2.5 - SCC 7.41 9.45 0.098 0.118 21 355 3 4 - SCC 4.61 5.88 0.092 0.110 28 570 3 6 - SCC 3.08 3.93 0.088 0.106 36 855 3 10 - SCC 1.83 2.33 0.084 0.100 50 1430 3 16 - SCC 1.15 1.47 0.080 0.096 67 2285 3 25 - SCC 0.727 0.927 0.080 0.097 89 3575 3 35 - SCC 0.524 0.669 0.078 0.093 110 5005 3 50 - SCC 0.387 0.494 0.074 0.089 137 7150 3 70 - SCC 0.268 0.343 0.073 0.088 169 10010 3 95 - SCC 0.193 0.248 0.072 0.086 205 13585 3 120 - SCC 0.153 0.198 0.070 0.084 237 17160 3 150 - SCC 0.124 0.162 0.071 0.085 272 21450

4G 1.5 - SCC 12.1 15.4 0112 0.134 16 210 4G 2.5 - SCC 7.41 9.45 0.105 0.126 21 355 4G 6 - SCC 3.08 3.93 0.095 0.114 36 855

326

Page 334: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TFXI Power cable 0.6/1 kV Halogen free shipcable

Page 5 of 6 20-7-2007

Conductors Conductor cross

section (mm2)

Screen cross

section (mm2)

Conductor type

Resistance at 20 oC

DC (Ohm/km)

Resistance at 90 oC 50 Hz

(Ohm/km)

Reactance at 50Hz

(Ohm/km)

Reactance at 60Hz

(Ohm/km)

Current rating

IEC60092-352 (A)

Short circuit rating 1sec (A)

4 1.5 - SCC 12.1 15.4 0.112 0.114 14 855 4 2.5 - SCC 7.41 9.45 0.105 0.134 18 210 4 4 - SCC 4.61 5.88 0.099 0.126 25 355 4 6 - SCC 3.08 3.93 0.095 0.119 32.5 570 4 10 - SCC 1.83 2.33 0.091 0.114 45 855 4 16 - SCC 1.15 1.47 0.087 0.109 60 1430

5G 1.5 - SCC 12.1 15.4 0.114 0.105 14 2285 5G 2.5 - SCC 7.41 9.45 0.108 0.137 18 210 5 1.5 - SCC 12.1 15.4 0.114 0.130 13 355 5 2.5 - SCC 7.41 9.45 0.108 0.137 16.5 210 6 1.5 - SCC 12.1 15.4 0.104 0.130 12.5 355 7 1.5 - SCC 12.1 15.4 0.104 0.125 12 210

8G 1.5 - SCC 12.1 15.4 0.104 0.125 12 210 8 1.5 - SCC 12.1 15.4 0.104 0.125 11.5 210

10 1.5 - SCC 12.1 15.4 0.104 0.125 10.5 210 12 1.5 - SCC 12.1 15.4 0.104 0.125 10 210 16 1.5 - SCC 12.1 15.4 0.104 0.125 9 210 19 1.5 - SCC 12.1 15.4 0.104 0.125 8.5 210 24 1.5 - SCC 12.1 15.4 0.104 0.125 7.5 210

SCC = Stranded Circular Conductor

Ordering information

Part number

Description EAN No. KDN

Stock Item

128234 TFXI cl5 0,6/1kV black 1x25 mm2 8711401105431 N 128235 TFXI cl5 0,6/1kV black 1x35 mm2 8711401105462 N 128236 TFXI cl5 0,6/1kV black 1x50 mm2 8711401105493 N 128237 TFXI cl5 0,6/1kV black 1x70 mm2 8711401105523 N 128636 TFXI cl5 0,6/1kV black 1x120 mm2 8711401116505 N 128243 TFXI cl5 0,6/1kV black 3x25 mm2 8711401105547 N 128244 TFXI cl5 0,6/1kV black 3x35 mm2 8711401105592 N 128245 TFXI cl5 0,6/1kV black 3x50 mm2 8711401105622 N 128246 TFXI cl5 0,6/1kV black 3x70 mm2 8711401105639 N 128460 TFXI cl5 0,6/1kV black 3x95 mm2 8711401109170 N 128624 TFXI 0,6/1kV black 1x10 mm2 8711401116475 N 128625 TFXI 0,6/1kV black 1x16 mm2 8711401116482 N 128626 TFXI 0,6/1kV black 1x25 mm2 8711401116499 N 128627 TFXI 0,6/1kV black 1x35 mm2 8711401116512 N 128628 TFXI 0,6/1kV black 1x50 mm2 8711401116529 N 128629 TFXI 0,6/1kV black 1x70 mm2 8711401116543 N 128630 TFXI 0,6/1kV black 1x95 mm2 8711401116550 N 128631 TFXI 0,6/1kV black 1x120 mm2 8711401116567 N 128634 TFXI 0,6/1kV black 1x150 mm2 8711401116598 N 128632 TFXI 0,6/1kV black 1x185 mm2 8711401116574 N 128633 TFXI 0,6/1kV black 1x240 mm2 8711401116581 N 128571 TFXI 0,6/1kV black 1x400 mm2 8711401115850 N 125130 TFXI 0,6/1kV black 2x1,5 mm2 8711401104854 Y 125131 TFXI 0,6/1kV black 2x2,5 mm2 8711401021236 Y 125132 TFXI 0,6/1kV black 2x4 mm2 8711401021250 Y 125134 TFXI 0,6/1kV black 2x6 mm2 8711401021274 Y 125144 TFXI 0,6/1kV black 2x10 mm2 8711401021427 Y 125119 TFXI 0,6/1kV black 2x16 mm2 8711401104861 Y 126442 TFXI 0,6/1kV black 3G1,5 mm2 8711401039187 N 126444 TFXI 0,6/1kV black 3G2,5 mm2 8711401039255 N 125104 TFXI 0,6/1kV black 3x1,5 mm2 8711401020833 Y 125015 TFXI 0,6/1kV black 3x2,5 mm2 8711401019943 Y 125105 TFXI 0,6/1kV black 3x4 mm2 8711401020857 Y 125106 TFXI 0,6/1kV black 3x6 mm2 8711401020871 Y

327

Page 335: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TFXI Power cable 0.6/1 kV Halogen free shipcable

Page 6 of 6 20-7-2007

Part number

Description EAN No. KDN

Stock Item

125107 TFXI 0,6/1kV black 3x10 mm2 8711401020888 Y 125109 TFXI 0,6/1kV black 3x16 mm2 8711401020901 Y 125088 TFXI 0,6/1kV black 3x25 mm2 8711401020666 Y 125110 TFXI 0,6/1kV black 3x35 mm2 8711401020918 Y 125089 TFXI 0,6/1kV black 3x50 mm2 8711401020673 Y 124994 TFXI 0,6/1kV black 3x70 mm2 8711401019721 Y 125090 TFXI 0,6/1kV black 3x95 mm2 8711401020680 Y 125112 TFXI 0,6/1kV black 3x120 mm2 8711401020932 N 125111 TFXI 0,6/1kV black 3x150 mm2 8711401020925 N 126443 TFXI 0,6/1kV black 4G1,5 mm2 8711401039231 N 126445 TFXI 0,6/1kV black 4G2,5 mm2 8711401039279 N 126446 TFXI 0,6/1kV black 4G6 mm2 8711401039293 N 125135 TFXI 0,6/1kV black 4x1,5 mm2 8711401034243 Y 125140 TFXI 0,6/1kV black 4x2,5 mm2 8711401021366 Y 125141 TFXI 0,6/1kV black 4x4 mm2 8711401021397 Y 125143 TFXI 0,6/1kV black 4x6 mm2 8711401021311 Y 125145 TFXI 0,6/1kV black 4x10 mm2 8711401021434 N 125146 TFXI 0,6/1kV black 4x16 mm2 8711401021465 Y 127385 TFXI 0,6/1kV black 5G1,5 mm2 8711401098979 N 127386 TFXI 0,6/1kV black 5G2,5 mm2 8711401098993 N 125441 TFXI 0,6/1kV black 5x1,5 mm2 8711401023933 N 125440 TFXI 0,6/1kV black 5x2,5 mm2 8711401023919 N 128639 TFXI 0,6/1kV black 6x1,5 mm2 8711401116659 N 128640 TFXI 0,6/1kV black 7x1,5 mm2 8711401116666 N 128647 TFXI 0,6/1kV black 8G1,5 mm2 8711401116741 N 128641 TFXI 0,6/1kV black 8x1,5 mm2 8711401116673 N 128642 TFXI 0,6/1kV black 10x1,5 mm2 8711401116680 N 128643 TFXI 0,6/1kV black 12x1,5 mm2 8711401116895 N 128644 TFXI 0,6/1kV black 16x1,5 mm2 8711401116703 N 128645 TFXI 0,6/1kV black 19x1,5 mm2 8711401116727 N 128646 TFXI 0,6/1kV black 24x1,5 mm2 8711401116734 N

Ambient temperature correction factors Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75 Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations Minimum bending radius

during installation Minimum bending radius

fixed installed Maximum tensile load

during installation Minimum installation

temperature 8 x D 6 x D 50 N * total cross section

conductors -20 °C

Subject to change without notice

328

Page 336: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TIOI(c) Instrumentation cable 250V Braided halogen free shipcable

Page 1 of 3 20-7-2007

TIOI(c) 250VXLPE/TCWB/SHF1 Max. conductor temp. : 90°CNominal v oltage : 250V

Application

Armoured cable for fixed installations on ships where cable protection is required. For instrumentation and communication systems. Can be installed and operated both indoors and

utdoors. o

Standards applied Design - IEC 60092-376 Conductor - IEC 60228 class 2 Insulation - IEC 60092-351 Sheath - IEC 60092-359 Flame retardant - IEC 60332-3-22 (cat A)Halogen Free - IEC 60754-1,2 Low smoke - IEC 61034-1,2

Construction

CODE

LETTER

Conductor Annealed stranded circular copper conductors

Insulation T Crosslinked polyethylene, XLPE

Lay up Numbered white cores twisted in pairs (two pair type may be built up

as a star quad). The pairs are twisted with different lay length to reduce mutual capacitance. One or more polyester tapes may be applied

Screen (c) Overall screen (polyester tape, tinned copper drain wire, metal coated polyester tape). A polyester tape is applied over the screen

Inner covering I Flame retardant halogen free thermoplastic compound, SHF1

Armour/screen O Tinned copper wire braid

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Marking text DRAKA factory code TIOI 250 V .. pair/triple/quad .. mm2 IEC60332-3-22 ShipLine year of manufacture length indication (meter)

Outer sheath colour

Grey

329

Page 337: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TIOI(c) Instrumentation cable 250V Braided halogen free shipcable

Page 2 of 3 20-7-2007

Identification of elements The pairs have the following number identification according to IEC 60092-376 Pair no. 1 core no. 1 and 2Pair no. 2 core no. 3 and 4Pair no. 3 core no. 5 and 6Pair no. 4 etc. The single triple is identified with no 1, 2 and 3 1 The single quad cable has thefollowing identification

4 + 3 2 Range and dimensions

Elements (pair) (triple) (quad)

Conductor cross

section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

1 pair 0.75 - 2.1 0.5 0.2 0.8 9.1 120 52 1 triple 0.75 - 2.1 0.5 0.2 0.8 9.4 135 62 1 quad 0.75 - 2.1 0.5 0.2 0.8 10.0 150 69 4 pair 0.75 - 2.1 0.5 0.3 0.9 14.2 290 147 7 pair 0.75 - 2.1 0.5 0.3 0.9 16.6 395 210 10 pair 0.75 - 2.1 0.5 0.3 1.0 19.6 510 264 14 pair 0.75 - 2.1 0.5 0.3 1.1 21.5 640 333 19 pair 0.75 - 2.1 0.5 0.3 1.1 23.7 785 419 24 pair 0.75 - 2.1 0.5 0.3 1.2 27.4 970 508

Electrical values Type Capacitance

approx. (nF/km)

Inductance Approx. (mH/km)

Resistance at 20 oC

(Ohm/km) Single pair/triple 0.75 mm2 70 0.60 26.0

Single quad 0.75 mm2 Multi pair/triple 0,75

60 75

0.50 0.60

26.0 26.0

330

Page 338: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TIOI(c) Instrumentation cable 250V Braided halogen free shipcable

Page 3 of 3 20-7-2007

Ordering information Part

number Description EAN No.

KDN Stock Item

125154 TIOI(c) 250V grey 1x2x0,75 mm2 8711401030665 Y 125156 TIOI(c) 250V grey 1x4x0,75 mm2 8711401021618 Y 127195 TIOI(c) 250V grey 1x3x0,75 mm2 8711401072146 N 125157 TIOI(c) 250V grey 4x2x0,75 mm2 8711401004284 Y 125159 TIOI(c) 250V grey 7x2x0,75 mm2 8711401030672 Y 125160 TIOI(c) 250V grey 10x2x0,75 mm2 8711401030726 Y 125161 TIOI(c) 250V grey 14x2x0,75 mm2 8711401030733 N 125162 TIOI(c) 250V grey 19x2x0,75 mm2 8711401030740 N 125163 TIOI(c) 250V grey 24x2x0,75 mm2 8711401030757 N

Installation recommendations

Minimum bending radius during installation

Minimum bending radius fixed installed

Maximum tensile load during installation

Minimum installation temperature

8 x D 6 x D 50 N * total cross section conductors

-20 °C

Subject to change without notice

331

Page 339: Prysmian Draka - Marine & Offshore LV HV Cables

TFOI 12kV(2).doc 21.06.2006 14:02

Page 1 of 2

Shipline TFOI 6/10(12)kV MV Power cable

Flame retardant halogen-free medium voltage (MV) power cable. Braided

TFOI 6/10(12) kVXLPE/EPR/TCWB/PO

Operating temperature : 90°COperating Voltage : 6/10(12) kV

Application

Armoured cable for fixed installation in ships where cable protection is required. Medium Voltage power distribution. Can be

d and operated both indoors and outdoors. installe

Standards applied

IEC 60092-354 - Design IEC 60228 class 2 - Conductor IEC 60092-351 - Insulation IEC 60092-359 - Sheath IEC 60332-1 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 600754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke

Construction

Code Letter

Conductor Annealed stranded circular copper, IEC 60228 class 2 Conductor screen semiconductive

Extruded semiconductive layer

Insulation T Crosslinked Polyethylene, IEC 60092-351 (HFXLPE) Insulation screen semicoductive

Extruded semiconductive layer. A copper tape is applied as a metallic screen above the insulation screen. The thickness of the copper tape is 0,1 mm.

Lay up / Shielding Cores are laid up together. Cores are identified by White, Black or Red threads under and over the metallic screen on each conductor.

Inner covering F Flame retardant and halogen-free thermoplastic compound Tape over bedding Additional tape may be applied Armour/screen O Tinned copper wire braid Tape over armour/screen

Additional tape may be applied

Outer sheath I Flame retardant halogen-free thermoplastic compound, SHF1 Marking text

E.g. "meter" "year" DRAKA NORSK KABEL TFOI 6/10(12)KV 3 x 95/50 mm2 IEC 60332-3-22 ShipLine

Outer sheath colour Red

www.drakaMOG.com Subject to change without prior notice

332

Page 340: Prysmian Draka - Marine & Offshore LV HV Cables

TFOI 12kV(2).doc 21.06.2006 14:02

Page 2 of 2

Shipline TFOI 6/10(12)kV MV Power cable

Range and dimensions

Number of elements

Cross section core, mm²

Cross section screen, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Bedding, mm

Diameter bedding, mm

Diameter Braid Wire, mm

Thickness Outer Sheath, mm

Diameter outer sheath, mm

Weight of Cable Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 95 10 11.2 3.4 1 22.5 ± 1 0.3 1.7 27 ± 1 1640 1094

1 150 10 14.2 3.4 1 26 ± 1 0.3 1.8 30.5 ± 1.5 2220 1542

3 95 50 11.2 3.4 1.8 48.5 ± 2 0.5 2.6 55.5 ± 2.5 6060 3390

3 120 60 12.6 3.4 1.8 52.5 ± 2.5 0.6 2.7 60 ± 3 7270 4291

Ordering information Part number Description EAN No. DNK EL No. KDN Part number EAN no. KDN

838504 TFOI 6/10(12)KV 1X 95/10mm2 7021528385045 - - - 838506 TFOI 6/10(12)KV 1X 150/10mm2 7021528385069 - - - 838525 TFOI 6/10(12)kV 3X 95/50mm² 7021528385250 - - - 838526 TFOI 6/10(12)kV 3X 120/60mm² 7021528385267 - - -

Electrical values power cables Number

of elements

Cross section core, mm²

Cross section screen,

mm²

Conductor type 2

Max. conductor resistance at 20°C, Ohm/km

Max. conductor resistance at 90°C, Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Capacitans per phase,

nF/km

Current rating IEC

60092-352,

Ampere

Short circuit

rating 1 second, Ampere

1 95 10 SCC 0.193 0.246 0.119 0.143 300 293 16800 1 150 10 SCC 0.124 0.158 0.113 0.136 360 389 21000 3 95 50 SCC 0.193 0.246 0.091 0.109 300 205 4900 3 120 60 SCC 0.153 0.195 0.088 0.106 330 237 9800

Ambient temperature correction factors Ambient Temp °C 35 40 45 50 55 60 65 70 75 80 Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius

Fixed Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature 15 x D 9 x D 50 N /mm² -10°C

www.drakaMOG.com Subject to change without prior notice

333

Page 341: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TIOI Power cable 0.6/1 kV Halogen free shipcable

Page 1 of 6 20-7-2007

TIOI 0.6/1kVXLPE/SHF1/TCWB/SHF1 Max. conductor temp. : 90°CNominal v oltage : 0.6/1 kV

Application

Armoured cable for fixed installations on ships where cable protection is required. For power, control and lighting systems. Can be installed and operated both indoors and

utdoors. o

Standards applied Design - IEC 60092-353 Conductor - IEC 60228 class 2 and 5Insulation - IEC 60092-351 Sheath - IEC 60092-359 Fire retardant - IEC 60332-3-22 (cat. A)Halogen Free - IEC 60754-1,2 Low smoke - IEC 61034-1,2

Construction

CODE

LETTER

Conductor Annealed stranded circular copper conductors, stranded acc IEC 60228 class 2 or flexible acc IEC 60228 class 5

Insulation T Crosslinked polyethylene, XLPE

Lay up Cores laid up in one or more layers; in case of cables with more

than 5 cores one or more tapes may be applied over the laid up cores

Inner sheath I Flame retardant halogen free thermoplastic compound SHF1

Armour/screen O Tinned copper wire braid

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

Marking text DRAKA factory code TIOI 0,6/1 kV ..x../.. mm2 IEC60332-3-22 ShipLine Plus year of manufacture length indication (meter)

Outer sheath colour

Black

334

Page 342: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TIOI Power cable 0.6/1 kV Halogen free shipcable

Page 2 of 6 20-7-2007

Core identification Single core Black Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black Multi core White with black numbers with yellow/green (optional) Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey Range and dimensions Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

Class 5 1 120 10 17.4 1.2 0.3 1.1 23.8 1505 1197 3 35 16 9.95 0.9 0.3 1.2 29.0 1815 1120 Class 2

1 10 2.5 5.4 0.7 0.2 0.8 9.9 205 126 1 16 2.5 6.4 0.7 0.2 0.8 11.0 275 183 1 25 4 8.1 0.9 0.2 0.9 13.1 405 278 1 35 6 9.4 0.9 0.3 0.9 14.7 540 400 1 50 6 10.8 1.0 0.3 0.9 16.3 685 515 1 70 6 12.8 1.1 0.3 1.0 18.7 930 714 1 95 10 14.7 1.1 0.3 1.0 20.7 1205 958 1 120 10 16.5 1.2 0.3 1.1 22.8 1490 1198 1 150 16 18.4 1.4 0.3 1.1 24.9 1800 1457 1 185 16 20.7 1.6 0.3 1.2 27.4 2210 1806 1 240 16 23.4 1.7 0.3 1.2 30.4 2815 2333 1 300 25 26.0 1.8 0.4 1.3 33.9 3530 2952 1 400 25 29.3 2.0 0.4 1.4 37.9 4465 3745 2 1.5 4 3.0 0.7 0.2 0.8 11.3 200 72 2 2.5 4 3.5 0.7 0.2 0.9 12.4 255 96 2 4 6 4.0 0.7 0.3 0.9 13.9 345 158 2 6 6 4.5 0.7 0.3 0.9 15.2 425 202 2 10 10 5.4 0.7 0.3 1.0 16.9 560 287 2 16 16 6.4 0.7 0.3 1.0 19.7 805 450 2 25 16 8.1 0.9 0.3 1.1 23.0 1120 611 2 35 16 9.4 0.9 0.3 1.2 25.9 1405 777

3G 1.5 4 3.0 0.7 0.2 0.8 12.0 235 93 3G 2.5 4 3.5 0.7 0.2 0.9 13.0 290 125 3 1.5 4 3.0 0.7 0.2 0.8 12.0 235 93 3 2.5 4 3.5 0.7 0.2 0.9 13.0 290 125 3 4 6 4.0 0.7 0.3 0.9 14.5 390 198

335

Page 343: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TIOI Power cable 0.6/1 kV Halogen free shipcable

Page 3 of 6 20-7-2007

Conductors Conductor cross

section (mm2)

Screen cross

section (mm2)

Insulated conductor diameter

(mm)

Insulation thickness

(mm)

Braid wires diameter

(mm)

Outer sheath

thickness (mm)

Outer sheath

diameter (mm)

Weight approx.

(kg/km)

Copper content approx. (kg/km)

3 6 6 4.5 0.7 0.3 0.9 15.9 485 254 3 10 10 5.4 0.7 0.3 1.0 17.9 665 376 3 16 16 6.4 0.7 0.3 1.0 20.7 950 593 3 25 16 8.1 0.9 0.3 1.1 24.5 1355 830 3 35 16 9.4 0.9 0.3 1.2 27.6 1740 1104 3 50 25 10.8 1.0 0.4 1.3 32.6 2425 1530 3 70 35 12.8 1.1 0.5 1.4 37.6 3355 2177 3 95 50 14.7 1.1 0.6 1.5 43.2 4570 3071 3 120 60 16.5 1.2 0.6 1.6 47.5 5680 3871 3 150 70 18.4 1.4 0.6 1.7 52.1 6780 4613 3 185 95 20.7 1.6 0.4 1.8 58.9 8680 5959

4G 1.5 4 3.0 0.7 0.2 0.9 12.8 265 108 4G 2.5 6 3.5 0.7 0.3 0.9 14.3 360 177 4 1.5 4 3.0 0.7 0.2 0.9 12.8 265 108 4 2.5 6 3.5 0.7 0.3 0.9 14.3 360 177 4 4 6 4.0 0.7 0.3 0.9 15.8 465 243 4 6 6 4.5 0.7 0.3 1.0 17.2 580 324 4 10 10 5.4 0.7 0.3 1.0 19.3 795 475 4 16 16 6.4 0.7 0.3 1.1 22.8 1155 737 4 25 16 8.1 0.9 0.3 1.2 26.7 1670 1174 4 35 16 9.4 0.9 0.3 1.2 30.0 2110 1410 4 50 25 10.8 1.0 0.4 1.4 35.9 3005 1978 4 70 35 12.8 1.1 0.4 1.5 41.3 4110 2777 4 95 50 14.7 1.1 0.6 1.6 47.6 5645 3934

5G 1.5 4 3.0 0.7 0.2 0.9 13.8 300 127 5G 2.5 6 3.5 0.7 0.3 0.9 15.5 420 208 5 1.5 4 3.0 0.7 0.2 0.9 13.8 300 127 5 2.5 6 3.5 0.7 0.3 0.9 15.5 420 208 6 1.5 6 3.0 0.7 0.3 0.9 14.6 335 174 6 2.5 6 3.5 0.7 0.3 0.9 16.1 423 236 7 1.5 6 3.0 0.7 0.3 0.9 14.6 345 188 7 2.5 6 3.5 0.7 0.3 0.9 16.1 445 257 8 1.5 6 3.0 0.7 0.3 0.9 15.9 400 211

10 1.5 10 3.0 0.7 0.3 1.0 17.9 470 254 12 1.5 10 3.0 0.7 0.3 1.0 18.6 525 284 16 1.5 10 3.0 0.7 0.3 1.0 20.3 640 357 19 1.5 10 3.0 0.7 0.3 1.1 21.6 725 400 24 1.5 10 3.0 0.7 0.3 1.1 24.8 920 494

336

Page 344: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TIOI Power cable 0.6/1 kV Halogen free shipcable

Page 4 of 6 20-7-2007

Electrical values Conductors Conductor

cross section (mm2)

Screen cross

section (mm2)

Conductor type

Resistance at 20 oC

DC (Ohm/km)

Resistance at 90 oC 50 Hz

(Ohm/km)

Reactance at 50Hz

(Ohm/km)

Reactance at 60Hz

(Ohm/km)

Current rating

IEC60092-352 (A)

Short circuit rating 1sec (A)

Class 5 1 120 10 SCC 0.161 0.2053 0.089 0.107 339 17160 3 35 16 SCC 0.554 0.7064 0.076 0.092 110 5005 Class 2

1 10 2.5 SCC 1.83 2.33 0.123 0.147 72 1430 1 16 2.5 SCC 1.15 1.47 0.114 0.137 96 2285 1 25 4 SCC 0.727 0.927 0.110 0.132 127 3575 1 35 6 SCC 0.524 0.669 0.106 0.128 157 5005 1 50 6 SCC 0.387 0.494 0.101 0.121 196 7150 1 70 6 SCC 0.268 0.343 0.097 0.117 242 10010 1 95 10 SCC 0.193 0.248 0.093 0.112 293 13585 1 120 10 SCC 0.153 0.198 0.091 0.109 339 17160 1 150 16 SCC 0.124 0.162 0.090 0.109 389 21450 1 185 16 SCC 0.0991 0.131 0.090 0.107 444 26455 1 240 16 SCC 0.0754 0.102 0.087 0.104 522 34320 1 300 25 SCC 0.0601 0.0766 0.087 0.104 601 42900 1 400 25 SCC 0.047 0.0685 0.086 0.103 670 57200 2 1.5 4 SCC 12.1 15.4 0.104 0.125 20 210 2 2.5 4 SCC 7.41 9.45 0.098 0.118 26 355 2 4 6 SCC 4.61 5.88 0.092 0.110 34 570 2 6 6 SCC 3.08 3.93 0.088 0.106 44 855 2 10 10 SCC 1.83 2.33 0.084 0.100 61 1430 2 16 16 SCC 1.15 1.47 0.080 0.096 82 2285 2 25 16 SCC 0.727 0.927 0.080 0.097 108 3575 2 35 16 SCC 0.524 0.669 0.078 0.093 133 5005

3G 1.5 4 SCC 12.1 15.4 0.104 0.125 20 210 3G 2.5 4 SCC 7.41 9.45 0.098 0.118 26 355 3 1.5 4 SCC 12.1 15.4 0.104 0.125 16 210 3 2.5 4 SCC 7.41 9.45 0.098 0.118 21 355 3 4 6 SCC 4.61 5.88 0.092 0.110 28 570 3 6 6 SCC 3.08 3.93 0.088 0.106 36 855 3 10 10 SCC 1.83 2.33 0.084 0.100 50 1430 3 16 16 SCC 1.15 1.47 0.080 0.096 67 2285 3 25 16 SCC 0.727 0.927 0.080 0.097 89 3575 3 35 16 SCC 0.524 0.669 0.078 0.093 110 5005 3 50 25 SCC 0.387 0.494 0.074 0.089 137 7150 3 70 35 SCC 0.268 0.343 0.073 0.088 169 10010 3 95 50 SCC 0.193 0.248 0.072 0.086 205 13585 3 120 60 SCC 0.153 0.198 0.070 0.084 237 17160 3 150 70 SCC 0.124 0.162 0.071 0.085 272 21450 3 185 95 SCC 0.0991 0.131 0.071 0.086 311 26455

4G 1.5 4 SCC 12.1 15.4 0.112 0.134 16 210 4G 2.5 6 SCC 7.41 9.45 0.105 0.126 21 355 4 1.5 4 SCC 12.1 15.4 0.112 0.134 14 855 4 2.5 6 SCC 7.41 9.45 0.105 0.126 18 210 4 4 6 SCC 4.61 5.88 0.099 0.119 25 355 4 6 6 SCC 3.08 3.93 0.095 0.114 32.5 570 4 10 10 SCC 1.83 2.33 0.091 0.109 45 855

337

Page 345: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TIOI Power cable 0.6/1 kV Halogen free shipcable

Page 5 of 6 20-7-2007

Conductors Conductor cross

section (mm2)

Screen cross

section (mm2)

Conductor type

Resistance at 20 oC

DC (Ohm/km)

Resistance at 90 oC 50 Hz

(Ohm/km)

Reactance at 50Hz

(Ohm/km)

Reactance at 60Hz

(Ohm/km)

Current rating

IEC60092-352 (A)

Short circuit rating 1sec (A)

4 16 16 SCC 1.15 1.47 0.087 0.105 60 1430 4 25 16 SCC 0.727 0.927 0.088 0.105 80 3575 4 35 16 SCC 0.524 0.669 0.085 0.102 98.5 5005 4 50 25 SCC 0.387 0.494 0.082 0.098 123 7150 4 70 35 SCC 0.268 0.343 0.080 0.097 152 10010 4 95 50 SCC 0.193 0.248 0.079 0.095 184.5 13585

5G 1.5 4 SCC 12.1 15.4 0.114 0.137 14 2285 5G 2.5 6 SCC 7.41 9.45 0.108 0.130 18 210 5 1.5 4 SCC 12.1 15.4 0.114 0.137 13 355 5 2.5 6 SCC 7.41 9.45 0.108 0.130 16.5 210 6 1.5 6 SCC 12.1 15.4 0.104 0.125 12.5 355 6 2.5 6 SCC 7.41 9.45 0.098 0.118 15.5 355 7 1.5 6 SCC 12.1 15.4 0.104 0.125 12 210 7 2.5 6 SCC 7.41 9.45 0.098 0.118 15 355 8 1.5 6 SCC 12.1 15.4 0.104 0.125 11.5 210

10 1.5 10 SCC 12.1 15.4 0.104 0.125 10.5 210 12 1.5 10 SCC 12.1 15.4 0.104 0.125 10 210 16 1.5 10 SCC 12.1 15.4 0.104 0.125 9 210 19 1.5 10 SCC 12.1 15.4 0.104 0.125 8.5 210 24 1.5 10 SCC 12.1 15.4 0.104 0.125 7.5 210

SCC = Stranded Circular Conductor

Ordering information

Part number

Description EAN No. KDN

Stock Item

128637 TIOI cl5 0,6/1kV black 1x120/10 mm2 8711401106536 N 128223 TIOI cl5 0,6/1kV black 3x35/16 mm2 8711401105301 N 125043 TIOI 0,6/1kV black 1x10/2,5 mm2 8711401020130 N 125044 TIOI 0,6/1kV black 1x16/2,5 mm2 8711401020154 Y 125047 TIOI 0,6/1kV black 1x25/4 mm2 8711401020161 N 125048 TIOI 0,6/1kV black 1x35/6 mm2 8711401020178 Y 125050 TIOI 0,6/1kV black 1x50/6 mm2 8711401020185 Y 125058 TIOI 0,6/1kV black 1x70/6 mm2 8711401020253 N 125059 TIOI 0,6/1kV black 1x95/10 mm2 8711401020260 N 125051 TIOI 0,6/1kV black 1x120/10 mm2 8711401020192 N 125053 TIOI 0,6/1kV black 1x150/16 mm2 8711401020208 N 125055 TIOI 0,6/1kV black 1x185/16 mm2 8711401020215 N 125056 TIOI 0,6/1kV black 1x240/16 mm2 8711401020222 N 127296 TIOI 0,6/1kV black 1x300/25 mm2 8711401083142 N 128714 TIOI 0,6/1kV black 1x400/25 mm2 8711401119421 N 125061 TIOI 0,6/1kV black 2x1,5/4 mm2 8711401020321 Y 125078 TIOI 0,6/1kV black 2x2,5/4 mm2 8711401119346 Y 125080 TIOI 0,6/1kV black 2x4/6 mm2 8711401119353 N 125081 TIOI 0,6/1kV black 2x6/6 mm2 8711401020499 N 125034 TIOI 0,6/1kV black 2x10/10 mm2 8711401020055 N 125035 TIOI 0,6/1kV black 2x16/16 mm2 8711401020062 N 127321 TIOI 0,6/1kV black 2x25/16 mm2 8711401093479 N 127328 TIOI 0,6/1kV black 2x35/16 mm2 8711401093493 N 127379 TIOI 0,6/1kV black 3G1,5/4 mm2 8711401095121 N 127380 TIOI 0,6/1kV black 3G2,5/4 mm2 8711401095145 N 125020 TIOI 0,6/1kV black 3x1,5/4 mm2 8711401020390 Y 125016 TIOI 0,6/1kV black 3x2,5/4 mm2 8711401119339 Y 125021 TIOI 0,6/1kV black 3x4/6 mm2 8711401020413 Y 125022 TIOI 0,6/1kV black 3x6/6 mm2 8711401119322 Y 125019 TIOI 0,6/1kV black 3x10 mm2 8711401019981 Y 125024 TIOI 0,6/1kV black 3x16 mm2 8711401119308 Y 125023 TIOI 0,6/1kV black 3x25 mm2 8711401019998 Y

338

Page 346: Prysmian Draka - Marine & Offshore LV HV Cables

Shipline Plus TIOI Power cable 0.6/1 kV Halogen free shipcable

Page 6 of 6 20-7-2007

Part number

Description EAN No. KDN

Stock Item

125069 TIOI 0,6/1kV black 3x35 mm2 8711401119292 Y 125067 TIOI 0,6/1kV black 3x50 mm2 8711401119285 Y 124995 TIOI 0,6/1kV black 3x70 mm2 8711401019745 N 125032 TIOI 0,6/1kV black 3x95 mm2 8711401020048 Y 125026 TIOI 0,6/1kV black 3x120 mm2 8711401119278 N 125030 TIOI 0,6/1kV black 3x150 mm2 8711401020024 N 128707 TIOI 0,6/1kV black 3x185 mm2 8711401119261 N 127381 TIOI 0,6/1kV black 4G1,5 mm2 8711401095169 N 127382 TIOI 0,6/1kV black 4G2,5 mm2 8711401095183 N 125082 TIOI 0,6/1kV black 4x1,5 mm2 8711401020512 Y 125092 TIOI 0,6/1kV black 4x2,5 mm2 8711401119360 Y 125094 TIOI 0,6/1kV black 4x4 mm2 8711401020734 N 125095 TIOI 0,6/1kV black 4x6 mm2 8711401020758 Y 125036 TIOI 0,6/1kV black 4x10 mm2 8711401020086 Y 125040 TIOI 0,6/1kV black 4x16 mm2 8711401020093 Y 125041 TIOI 0,6/1kV black 4x25 mm2 8711401020116 Y 128022 TIOI 0,6/1kV black 4x35 mm2 8711401102638 N 128024 TIOI 0,6/1kV black 4x50 mm2 8711401102768 N 128023 TIOI 0,6/1kV black 4x70 mm2 8711401102720 N 128025 TIOI 0,6/1kV black 4x95 mm2 8711401102782 N 127383 TIOI 0,6/1kV black 5G1,5 mm2 8711401097729 N 127384 TIOI 0,6/1kV black 5G2,5 mm2 8711401098955 N 125407 TIOI 0,6/1kV black 5x1,5 mm2 8711401023537 Y 125408 TIOI 0,6/1kV black 5x2,5 mm2 8711401023551 N 125096 TIOI 0,6/1kV black 6x1,5 mm2 8711401020772 Y 125100 TIOI 0,6/1kV black 6x2,5 mm2 8711401020819 N 125099 TIOI 0,6/1kV black 7x1,5 mm2 8711401020796 Y 125117 TIOI 0,6/1kV black 7x2,5 mm2 8711401020956 N 125118 TIOI 0,6/1kV black 8x1,5 mm2 8711401020970 Y 125122 TIOI 0,6/1kV black 10x1,5 mm2 8711401021038 Y 125123 TIOI 0,6/1kV black 12x1,5 mm2 8711401021090 Y 125126 TIOI 0,6/1kV black 16x1,5 mm2 8711401021144 Y 125127 TIOI 0,6/1kV black 19x1,5 mm2 8711401021168 Y 125128 TIOI 0,6/1kV black 24x1,5 mm2 8711401021175 N

Ambient temperature correction factors Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75 Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations Minimum bending radius

during installation Minimum bending radius

fixed installed Maximum tensile load

during installation Minimum installation

temperature 8 x D 6 x D 50 N * total cross section

conductors -20 °C

Subject to change without notice

339

Page 347: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable

Fire resistant, Flame retardant halogen-free power cable. Enhanced oil-resistance.

BFCU 0.6/1kV

Operating temperature : 90°C

Operating Voltage : 0.6/1kV

Armoured cable for fixed installation for power, control or lighting in both EX and safe areas, emergency and critical systems where there is a requirement for fire resistant cables. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606.

Application Standards applied BS7917/BS6883/UKOOA - Design

BS6360 class 2 - Conductor

BS7655 section 1.2 - Insulation

BS7655 section 2.6 - Sheath

IEC 60332-1 &3-22 - Flame Retardant

IEC60331-21 - Fire Resistant

IEC60754-1,2 - Halogen Free

IEC 61034-1,2 - Low Smoke

Code Letter

Conductor Tinned stranded circular copper, BS 6360, class 2

Insulation B Mica glass tape / EP-rubber, GP4 to BS 7655: section 1.2

Lay up / Shielding Cores laid up in concentric layers

Inner covering F Flame retardant and halogen-free thermoplastic EP-rubber based compound

Tape over inner covering PET tape + rubberized Polyamide tape

Armour/screen C Galvanized steel wire braid

Tape over armour/screen PET tape + rubberised Polyamide tape

Outer sheath U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6

Marking text

"metre mark" "year" "DRAKA" "BFCU" "UKOOA code" "600/1000V" "number of cores" "conductor size" "BS7917" "IEC60331-21” “IEC60332-3-22" (marking may differ on cable actually supplied)

Outer sheath colour Black

Construction

Core identification All cores are offwhite with black numbers No 1,2,3…….

www.drakaMOG.com Information subject to change without notice

340

Page 348: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable

Number of cores

Cross section

core, mm²

Conductor Diameter,

mm

Insulation Thickness,

mm

Thickness Inner

Sheath, mm

Approx Diameter

Inner Sheath,

mm

Diameter Braid Wire,

mm

Thickness Outer

Sheath, mm

Approx Overall

Diameter, mm

Weight of Cable

Approx. (Kg/Km)

Copper content Approx. (kg/km)

2 2.5 2.0 0.8 1.1 10 0.3 1.2 14 350 46 3 1.5 1.6 0.8 1.1 10 0.3 1.2 14 340 42 3 2.5 2.0 0.8 1.1 10.5 0.3 1.3 15 410 69 4 1.5 1.6 0.8 1.1 11 0.3 1.3 15 400 56 4 2.5 2.0 0.8 1.1 11.5 0.3 1.3 16 450 92 7 2.5 2.0 0.8 1.2 14 0.3 1.4 18.5 620 161 12 2.5 2.0 0.8 1.4 19 0.3 1.6 24 960 275 27 2.5 2.0 0.8 1.7 27.5 0.45 1.9 33.5 1900 618 19 2.5 2.0 0.8 1.5 22.5 0.3 1.7 27.5 1360 435 4 70 10.85 1.4 2.1 38 0.45 2.4 45 4650 2484 3 4 2.55 1.0 1.2 13 0.3 1.3 17 540 110 2 1.5 1.6 0.8 1.1 9.5 0.3 1.2 13 295 28 12 1.5 1.6 0.8 1.3 17.5 0.3 1.5 22 770 167 3 6 3.15 1.0 1.2 14.5 0.3 1.4 18.5 650 164 2 4 2.55 1.0 1.2 12.5 0.3 1.3 16.5 470 74 3 10 4.05 1.0 1.3 16.5 0.3 1.5 21 840 271 2 10 4.05 1.0 1.3 15.5 0.3 1.4 20 710 181 3 25 6.45 1.2 1.6 23.5 0.3 1.8 28.5 1710 688 2 6 3.15 1.0 1.2 13.5 0.3 1.4 18 570 109 2 16 5.15 1.0 1.4 18 0.3 1.5 22.5 780 289 4 6 3.15 1.0 1.3 16 0.3 1.5 20.5 790 218 4 35 7.65 1.2 1.8 29 0.45 2 35 2700 1236 2 35 7.65 1.2 1.6 24.5 0.3 1.8 29.5 1740 618 3 35 7.65 1.2 1.7 26 0.45 1.9 32 2210 927 3 16 5.15 1.0 1.4 19 0.3 1.6 24 1160 434 3 50 9.0 1.4 1.8 30.5 0.45 2 36.5 2890 1293 3 70 10.85 1.4 2 34.5 0.45 2.2 41 3810 1863 4 4 2.55 1.0 1.2 14.5 0.3 1.4 18.5 630 147 3 95 12.60 1.6 2.2 39.5 0.45 2.4 46.5 4950 2513 7 1.5 1.6 0.8 1.2 13 0.3 1.3 17 520 98

Range and dimensions

341

Page 349: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable

Part number Description Sheath Colour Design standard UKOOA Code

840073 BFCU 0.6/1kV 2X 2.5mm² BLACK BS 7917 : 1999 YD203

840074 BFCU 0.6/1kV 3X 1.5mm² BLACK BS 7917 : 1999 YD302

840075 BFCU 0.6/1kV 3X 2.5mm² BLACK BS 7917 : 1999 YD303

840076 BFCU 0.6/1kV 4X 1.5mm² BLACK BS 7917 : 1999 YD402

840077 BFCU 0.6/1kV 4X 2.5mm² BLACK BS 7917 : 1999 YD403

840078 BFCU 0.6/1kV 7X 2.5mm² BLACK BS 7917 : 1999 YD703

840079 BFCU 0.6/1kV 12X 2.5mm² BLACK BS 7917 : 1999 YDA03

840108 BFCU 0.6/1kV 27X 2.5mm² BLACK BS 6883 : 1991 YDC03

840136 BFCU 0.6/1kV 19X 2.5mm² BLACK BS 7917 : 1999 YDB03

840151 BFCU 0,6/1kV 4X 70 MM2 BLACK BS 7917 : 1999 YD470

840153 BFCU 0.6/1kV 3X 4mm² BLACK BS 7917 : 1999 YD304

840162 BFCU 0.6/1kV 2X 1.5mm² BLACK BS 7917 : 1999 YD202

840165 BFCU 0,6/1kV 12X 1,5mm2 BLACK BS 7917 : 1999 YDA02

840167 BFCU 0.6/1kV 3X 6mm² BLACK BS 7917 : 1999 YD306

840230 BFCU 0.6/1kV 2X 4mm² BLACK BS 7917 : 1999 YD204

840233 BFCU 0.6/1kV 3X 10mm² BLACK BS 7917 : 1999 YD310

840243 BFCU 0,6/1kV 2X 10MM2 BLACK BS 7917 : 1999 YD210

840248 BFCU 0.6/1kV 3X 25mm² BLACK BS 7917 : 1999 YD325

840249 BFCU 0.6/1kV 2X 6mm² BLACK BS 7917 : 1999 YD206

840250 BFCU 0,6/1kV 2X 16 MM2 BLACK BS 7917 : 1999 YD216

840257 BFCU 0.6/1kV 4X 6mm² BLACK BS 7917 : 1999 YD406

Ordering information

840259 BFCU 0.6/1kV 4X 35mm² BLACK BS 7917 : 1999 YD435

840270 BFCU 0.6/1kV 2X 35mm² BLACK BS 7917 : 1999 YD235

840273 BFCU 0.6/1kV 3X 35mm² BLACK BS 7917 : 1999 YD335

840297 BFCU 0.6/1kV 3X 16mm² BLACK BS 7917 : 1999 YD316

840298 BFCU 0.6/1kV 3X 50mm² BLACK BS 7917 : 1999 YD350

840299 BFCU 0.6/1kV 3X 70mm² BLACK BS 7917 : 1999 YD370

840308 BFCU 0.6/1kV 4X 4mm² BLACK BS 7917 : 1999 YD404

840309 BFCU 0.6/1kV 3X 95mm² BLACK BS 7917 : 1999 YD370

840310 BFCU 0.6/1kV 7X 1.5mm² BLACK BS 7917 : 1999 YD702

342

Page 350: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable

Number of cores

Cross section core, mm²

Max. conductor resistance at

20°C, Ohm/km

Max. conductor resistance at

90°C, Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Current rating IEC 60092-352

Table B.4, Ampere

Short circuit rating 1 second, Ampere

2 2.5 7.56 9.64 0.101 0.121 26 350 3 1.5 12.2 15.6 0.108 0.130 16 210 3 2.5 7.56 9.64 0.101 0.121 21 350 4 1.5 12.2 15.6 0.108 0.130 16 210 4 2.5 7.56 9.64 0.101 0.121 21 350 7 2.5 7.56 9.64 0.101 0.121 15.5 350

12 2.5 7.56 9.64 0.101 0.121 13 350 27 2.5 7.56 9.64 0.101 0.121 10 350 19 2.5 7.56 9.64 0.101 0.121 11 350 4 70 0.27 0.344 0.075 0.090 169 9800 3 4 4.7 5.99 0.100 0.120 28 560 2 1.5 12.2 15.6 0.108 0.130 20 210

12 1.5 12.2 15.6 0.108 0.130 10 210 3 6 3.11 3.97 0.094 0.112 36 840 2 4 4.7 5.99 0.100 0.120 34 560 3 10 1.84 2.35 0.088 0.105 50 1400 2 10 1.84 2.35 0.088 0.105 61 1400 3 25 0.734 0.936 0.081 0.097 89 3500 2 6 3.11 3.97 0.094 0.112 44 840 2 16 1.16 1.48 0.082 0.099 80 2240 4 6 3.11 3.97 0.094 0.112 36 840 4 35 0.529 0.675 0.078 0.094 110 4900 2 35 0.529 0.675 0.078 0.094 133 4900 3 35 0.529 0.675 0.078 0.094 110 4900 3 16 1.16 1.48 0.082 0.099 67 2240 3 50 0.391 0.499 0.078 0.093 137 7000 3 70 0.27 0.344 0.075 0.090 169 9800 4 4 4.7 5.99 0.100 0.120 28 560 3 95 0.195 0.249 0.075 0.090 205 13300 7 1.5 12.2 15.6 0.108 0.130 12 210

Electrical values

Minimum Bending Radius during Installation

Minimum Bending Radius Fixed Installed

Maximum Tensile Load During Installation

Minimum Installation Temperature

8 x D OD < 25 mm - 4 x D, OD > 25 mm - 6 x D 50 N /mm² -20°C

Installation recommendations

Ambient Temp °C 35 40 45 50 55 60 65 70 75 80

Rating factor 1.11 1.05 1.00 0.94 0.88 0.82 0.75 0.67 0.50 0.47

Ambient temperature correction factors

343

Page 351: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

BFCU(C) 250V, Fire Resistant, Collective screened instrumentation

Fire resistant, Flame retardant halogen-free instrumentation cable. Enhanced oil-resistance.

BFCU(C) 250V

Operating temperature : 90°C

Operating Voltage : 250V

Fixed installation for instrumentation, communication, control and alarm systems in both EX– and safe areas, emergency and critical systems where there is a requirement for fire resistant cables.. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606.

Application Standards applied BS7917/BS6883/UKOOA - Design

BS6360 class 2 or 5 - Conductor

BS7655 section 1.2 - Insulation

BS7655 section 2.6 - Sheath

IEC 60332-1 & 3-22 - Flame Retardant

IEC60331-21 - Fire Resistant

IEC60754-1,2 - Halogen Free

IEC 61034-1,2 - Low Smoke

Code Letter

Conductor Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5) Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)

Insulation B Mica Glass Tape / EP-rubber, GP4 to BS 7655: section 1.2

Pair/Triple/Quad twisting

Colour coded cores twisted together to form a pair, triple or quad, wrapped with polyester tape. Pairs, triples or quads are laid up, collectively screened with aluminium backed polyester tape with tinned copper drain wire. Pairs, triples, or quads are identified by numbers printed directly on the insulated conductors.

Inner covering F Flame retardant and halogen-free thermoplastic EP-rubber based compound

Tape over inner covering PET tape + rubberized Polyamide tape

Armour/screen C Galvanized steel wire braid

Tape over armour/screen PET tape + rubberised Polyamide tape

Outer sheath U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6

Marking text

"metre mark" "year" "DRAKA" "BFCU(C)" "UKOOA code" "150/250V" "number of pair, triples or quads" "conductor size" "BS7917" “IEC60331-21” "IEC60332-3-22" (marking may differ on cable actually supplied)

Outer sheath colour Grey or Blue

Construction

Core identification Pair - Black—White, numbered 1-1, 2-2, 3-3 …… Triple— Black—White—Red, numbered 1-1-1, 2-2-2, 3-3-3 …… Quad— Black—White—Red—Blue, numbered 1-1-1-1, 2-2-2-2 ….. Each core is identified by contrasting numerals & words repeated along the whole length of the cable.

www.drakaMOG.com Information subject to change without notice

344

Page 352: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

BFCU(C) 250V, Fire Resistant, Collective screened instrumentation

Range and dimensions

Number of

elements

No of cores in element

Cross section

core, mm²

Conductor Diameter,

mm

Insulation Thickness

mm

Thickness Inner

Sheath, mm

Approx Diameter

Inner Sheath,

mm

Diameter Braid

Wire, mm

Thickness Outer

Sheath, mm

Approx Overall

Diameter mm

Weight of Cable

Approx. (Kg/Km)

Copper content Approx. (kg/km)

3 2 0.75 1.15 0.8 1.2 13 0.3 1.4 17.5 460 45 7 2 0.75 1.15 0.8 1.4 17.5 0.3 1.5 22 740 98

12 2 0.75 1.15 0.8 1.6 22.5 0.3 1.7 27.5 1120 164 19 2 0.75 1.15 0.8 1.7 26 0.45 1.9 32 1600 258 27 2 0.75 1.15 0.8 1.9 31 0.45 2.2 37.5 2190 360 3 2 0.75 1.15 0.8 1.2 13 0.3 1.4 17.5 460 45 7 2 0.75 1.15 0.8 1.4 17.5 0.3 1.5 22 740 98

12 2 0.75 1.15 0.8 1.6 22.5 0.3 1.7 27.5 1120 164 19 2 0.75 1.15 0.8 1.7 26 0.45 1.9 32 1600 258 27 2 0.75 1.15 0.8 1.9 31 0.45 2.2 37.5 2190 360 3 2 1 1.3 0.8 1.2 13.5 0.3 1.4 18 490 58 2 2 1.5 1.6 0.8 1.2 13.5 0.3 1.4 18 470 57

20 2 0.75 1.15 0.8 1.8 27 0.45 2 33 1720 271 3 2 1.5 1.6 0.8 1.3 14.5 0.3 1.4 19 570 82 7 2 1.5 1.6 0.8 1.4 19.5 0.3 1.6 24 920 183

12 2 1.5 1.6 0.8 1.7 26 0.45 1.9 31.5 1560 310 20 2 0.75 1.15 0.8 1.8 27 0.45 2 33 1720 271 20 2 1.5 1.6 0.8 1.9 31 0.45 2.2 37.5 2260 511 27 2 1.5 1.6 0.8 2.1 35.5 0.45 2.4 42 2820 688 7 3 0.75 1.15 0.8 1.4 19.5 0.3 1.6 24.5 930 144

12 3 0.75 1.15 0.8 1.7 26 0.3 1.9 31.5 1450 245 3 2 2.5 2 0.8 1.3 16 0.3 1.5 20.5 680 147

12 2 2.5 2 0.8 1.8 28.5 0.45 2 34.5 1960 565 2 2 0.75 1.15 0.8 1.2 12 0.3 1.3 16.5 390 31 3 3 0.75 1.15 0.8 1.3 15 0.3 1.4 19 550 65 7 3 1.5 1.6 0.8 1.5 22 0.3 1.7 27 1180 271

12 3 1.5 1.6 0.8 1.8 29.5 0.45 2 35.5 2020 462 7 2 1.5 1.6 0.8 1.4 19.5 0.3 1.6 24 920 183

20 2 1.5 1.6 0.8 1.9 31 0.45 2.2 37.5 2260 511 2 2 1.5 1.6 0.8 1.2 13.5 ± 0.8 0.3 1.4 18 ± 0.8 470 57 3 2 1.5 1.6 0.8 1.3 14.5 ± 0.8 0.3 1.4 19 ± 0.8 570 82 5 2 1.5 1.6 0.8 1.4 18 ± 0.8 0.3 1.6 22.5 ± 1 780 133 5 2 1.5 1.6 0.8 1.4 18 ± 0.8 0.3 1.6 22.5 ± 1 780 133 7 2 1.5 1.6 0.8 1.4 19.5 ± 0.8 0.3 1.6 24 ± 1 920 183 2 2 0.75 1.15 0.8 1.2 12 ± 0.8 0.3 1.3 16.5 ± 0.8 390 31 3 2 1 1.3 0.8 1.2 13.5 ± 0.8 0.3 1.4 18 ± 0.8 490 58 5 2 0.75 1.15 0.8 1.3 15.5 ± 0.8 0.3 1.5 20 ± 1 620 71 5 2 0.75 1.15 0.8 1.3 15.5 ± 0.8 0.3 1.5 20 ± 1 620 71

12 2 1.5 1.6 0.8 1.7 26 ± 1 0.45 1.9 31.5 ± 1.5 1560 310 345

Page 353: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

BFCU(C) 250V, Fire Resistant, Collective screened instrumentation

Type Capacitance, approx. (nF/km)

Inductance, approx, (mH/km)

Resistance at 20°C, max. (Ohm/

km)

L/R ratio, (microH/Ohm)

Insulation resistance

(Minimum MOhm x km)

Unshielded pair 0,75 mm² 80 0,75 26,7 14 940 Unshielded triple 0,75 mm² 80 0,75 26,7 14 940 Unshielded pair 1,0 mm² 85 0,73 20,0 18 840 Unshielded triple 1,0 mm² 85 0,73 20,0 18 840 Unshielded pair 1,5 mm² 90 0,68 13,7 24,8 730 Unshielded triple 1,5 mm² 90 0,68 13,7 24,8 730 Unshielded pair 2,5 mm² 90 0,70 7,56 46,3 620 Unshielded triple 2,5 mm² 90 0,70 7,56 46,3 620

Electrical values

Part number Description Sheath Colour Design standard UKOOA Code

840011 BFCU(C) 250V 3PAIR 0.75mm² GREY BS 7917 : 1999 GNH00

840012 BFCU(C) 250V 7PAIR 0.75mm² GREY BS 7917 : 1999 GNJ00

840013 BFCU(C) 250V 12PAIR 0.75mm² GREY BS 7917 : 1999 GNK00

840014 BFCU(C) 250V 19PAIR 0.75mm² GREY BS 6883 : 1991 -

840015 BFCU(C) 250V 27PAIR 0.75mm² GREY BS 7917 : 1999 GNM00

840031 BFCU(C) 250V 3PAIR 0.75mm² BLUE BS 7917 : 1999 GLH00

840032 BFCU(C) 250V 7PAIR 0.75mm² BLUE BS 7917 : 1999 GLJ00

840033 BFCU(C) 250V 12PAIR 0.75mm² BLUE BS 7917 : 1999 GLK00

840034 BFCU(C) 250V 19PAIR 0.75mm² BLUE BS 6883 : 1991 -

840035 BFCU(C) 250V 27PAIR 0.75mm² BLUE BS 7917 : 1999 GLM00

840090 BFCU(C) 250V 3PAIR 1mm² BLUE BS 7917 : 1999 GLH01

840111 BFCU(C) 250V 2PAIR 1.5mm² BLUE BS 6883 : 1991 -

840124 BFCU(C) 250V 20PAIR 0.75mm² GREY BS 7917 : 1999 GNL00

840132 BFCU(C) 250V 3PAIR 1.5mm² GREY BS 6883 : 1991 GNH02

840133 BFCU(C) 250V 7PAIR 1.5mm² GREY BS 6883 : 1991 GNJ02

840134 BFCU(C) 250V 12PAIR 1.5mm² GREY BS 6883 : 1991 GNK02

840144 BFCU(C) 250V 20PAIR 0.75mm² BLUE BS 7917 : 1999 GLL00

840171 BFCU(C) 250V 20PAIR 1.5mm² GREY BS 6883 : 1991 GNL02

840172 BFCU(C) 250V 27PAIR 1.5mm² GREY BS 6883 : 1991 GNM02

840173 BFCU(C) 250V 7TRIP 0.75mm² GREY BS 7917 : 1999 GNT00

840174 BFCU(C) 250V 12TRIP 0.75mm² GREY BS 7917 : 1999 GNU00

Ordering information

346

Page 354: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

BFCU(C) 250V, Fire Resistant, Collective screened instrumentation

Minimum Bending Radius during Installation

Minimum Bending Radius Fixed Installed

Maximum Tensile Load During Installation

Minimum Installation Temperature

10 x D 8 x D 50 N /mm² -20°C

Installation recommendations

840203 BFCU(C) 250V 3PAIR 2.5mm² GREY BS 6883 : 1991 GNH03

840205 BFCU(C) 250V 12PAIR 2.5mm² GREY BS 6883 : 1991 GNK03

840220 BFCU(C) 250V 2PAIR 0.75mm² GREY BS 6883 : 1991 -

840255 BFCU(C) 250V 3TRIP 0.75mm² GREY BS 7917 : 1999 GNS00

840260 BFCU(C) 250V 7TRIP 1.5mm² GREY BS 6883 : 1991 GNT02

840261 BFCU(C) 250V 12TRIP 1.5mm² GREY BS 6883 : 1991 GNU02

840265 BFCU(C) 250V 7PAIR 1.5mm² BLUE BS 6883 : 1991 GLJ02

840266 BFCU(C) 250V 20PAIR 1.5mm² BLUE BS 6883 : 1991 GLL02

840285 BFCU(C) 250V 2PAIR 1.5mm² GREY BS 6883 : 1991 -

840286 BFCU(C) 250V 3PAIR 1.5mm² BLUE BS 6883 : 1991 GLH02

840287 BFCU(C) 250V 5PAIR 1.5mm² GREY BS 6883 : 1991 -

840288 BFCU(C) 250V 5PAIR 1.5mm² BLUE BS 6883 : 1991 -

840289 BFCU(C) 250V 7PAIR 1.5mm² BLUE BS 6883 : 1991 GLJ02

840317 BFCU(C) 250V 2PAIR 0.75mm² BLUE BS 6883 : 1991 -

840318 BFCU(C) 250V 3PAIR 1mm² GREY BS 7917 : 1999 GNH01

840319 BFCU(C) 250V 5PAIR 0.75mm² GREY BS 6883 : 1991 -

840320 BFCU(C) 250V 5PAIR 0.75mm² BLUE BS 6883 : 1991 -

840321 BFCU(C) 250V 12PAIR 1.5mm² BLUE BS 6883 : 1991 GLK02

Part number Description Sheath Colour Design standard UKOOA Code

347

Page 355: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

BFCU(I) 250V, Fire Resistant, Individual screened instrumentation

Fire resistant, Flame retardant halogen-free instrumentation cable. Enhanced oil-resistance.

BFCU(I) 250V

Operating temperature : 90°C

Operating Voltage : 250V

Fixed installation for instrumentation, communication, control and alarm systems in both EX– and safe areas, emergency and critical systems where there is a requirement for fire resistant cables.. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606.

Application Standards applied BS7917/6883/UKOOA - Design

BS6360 class 2 or 5 - Conductor

BS7655 section 1.2 - Insulation

BS7655 section 2.6 - Sheath

IEC 60332-1 & 3-22 - Flame Retardant

IEC60331-21 - Fire Resistant

IEC60754-1,2 - Halogen Free

IEC 61034-1,2 - Low Smoke

Code Letter

Conductor Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5) Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)

Insulation B Mica Glass Tape / EP-rubber, GP4 to BS 7655: section 1.2

Pair/Triple/Quad twisting / lay up

Colour coded cores twisted together to form a pair, triple or quad, which is individually screened with aluminium backed polyester tape with a tinned copper drain wire. Each pair, triple or quad is wrapped with polyester tape to prevent electrical contact with adjacent pairs, triples or quads. Individually shielded pairs, triples or quads are laid up in concentric layers and wrapped with a PETP tape. Pairs, triples, or quads are identified by numbers printed directly on the insulated conductors.

Inner covering F Flame retardant and halogen-free thermoplastic EP-rubber based compound

Tape over inner covering PET tape + rubberized Polyamide tape

Armour/screen C Galvanized steel wire braid

Tape over armour/screen PET tape + rubberised Polyamide tape

Outer sheath U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6

Marking text "metre mark" "year" "DRAKA" "BFCU(I)" "UKOOA code" "150/250V" "number of pair, triples or quads" "conductor size" "BS7917" “IEC60331-21” "IEC60332-3-22" (marking may differ on cable actually supplied)

Outer sheath colour Grey or Blue

Construction

Core identification Pair - Black—White, numbered 1-1, 2-2, 3-3 …… Triple— Black—White—Red, numbered 1-1-1, 2-2-2, 3-3-3 …… Quad— Black—White—Red—Blue, numbered 1-1-1-1, 2-2-2-2 ….. Each core is identified by contrasting numerals & words repeated along the whole length of the cable.

www.drakaMOG.com Information subject to change without notice

348

Page 356: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

BFCU(I) 250V, Fire Resistant, Individual screened instrumentation

Range and dimensions

Number of

elements

No of cores in element

Cross section

core, mm²

Conductor Diameter,

mm

Insulation Thickness

mm

Thickness Inner

Sheath, mm

Approx Diameter

Inner Sheath,

mm

Diameter Braid

Wire, mm

Thickness Outer

Sheath, mm

Approx Overall

Diameter mm

Weight of Cable

Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 2 0.75 1.15 0.8 1 8 0.3 1.2 12 260 18

1 4 0.75 1.15 0.8 1.2 10 0.3 1.3 14 330 31

1 3 0.75 1.15 0.8 1 8.5 0.3 1.2 12.5 280 25

3 3 0.75 1.15 0.8 1.3 14.5 0.3 1.5 19 590 73

7 3 0.75 1.15 0.8 1.5 20 0.3 1.7 24.5 990 171

12 3 0.75 1.15 0.8 1.7 26.5 0.45 2 32.5 1640 293

1 2 0.75 1.15 0.8 1 8 0.3 1.2 12 245 18

1 4 0.75 1.15 0.8 1.2 10 0.3 1.3 14 330 31

1 3 0.75 1.15 0.8 1 8.5 0.3 1.2 12.5 280 25

3 3 0.75 1.15 0.8 1.3 14.5 0.3 1.5 19 590 73

7 3 0.75 1.15 0.8 1.5 20 0.3 1.7 24.5 990 171

12 3 0.75 1.15 0.8 1.7 26.5 0.45 2 32.5 1640 293

1 2 1.5 1.6 0.8 1.1 9.5 0.3 1.2 13 300 32

1 4 1.5 1.6 0.8 1.2 11 0.3 1.4 15.5 410 57

1 2 1.5 1.6 0.8 1.1 9.5 0.3 1.2 13 300 32

1 4 1.5 1.6 0.8 1.2 11 0.3 1.4 15.5 410 57

1 3 1.5 1.6 0.8 1.1 10 0.3 1.2 14 330 45

1 2 1 1.3 0.8 1 8.5 0.3 1.2 12.5 270 24

1 2 1 1.3 0.8 1 8.5 0.3 1.2 12.5 270 24

7 2 0.75 1.15 0.8 1.4 18 0.3 1.6 22.5 800 124

1 3 1 1.3 0.8 1.1 9 0.3 1.2 13 310 32

1 3 1.5 1.6 0.8 1.1 10 0.3 1.2 14 330 45

7 2 1.5 1.6 0.8 1.5 20.5 0.3 1.7 25 1030 222

7 2 1.5 1.6 0.8 1.5 20.5 0.3 1.7 25 1030 222

2 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18.5 500 64

1 4 1 1.3 0.8 1.2 10 0.3 1.4 14.5 360 41

1 4 1 1.3 0.8 1.2 10 0.3 1.4 14.5 360 41

1 3 1 1.3 0.8 1.1 9 0.3 1.2 13 310 32

7 2 0.75 1.15 0.8 1.4 18 0.3 1.6 22.5 800 124

20 2 0.75 1.15 0.8 1.9 30 0.45 2.1 36.5 2040 354

1 4 2.5 2 0.8 1.3 12 0.3 1.5 16.5 500 100

3 2 0.75 1.15 0.8 1.2 13.5 0.3 1.4 17.5 480 53

3 2 1 1.3 0.8 1.3 14 0.3 1.4 18.5 520 71

3 2 0.75 1.15 0.8 1.2 13.5 0.3 1.4 17.5 480 53 349

Page 357: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

BFCU(I) 250V, Fire Resistant, Individual screened instrumentation

12 2 0.75 1.15 0.8 1.6 24 0.3 1.8 29 1240 213

20 2 0.75 1.15 0.8 1.9 30 0.45 2.1 36.5 2040 354

5 2 0.75 1.15 0.8 1.3 16 0.3 1.5 20.5 660 89

3 2 1.5 1.6 0.8 1.3 15 0.3 1.5 19.5 600 96

5 2 0.75 1.15 0.8 1.3 16 0.3 1.5 20.5 660 89

20 2 1.5 1.6 0.8 2 34 0.45 2.3 41 2640 636

1 4 1.5 1.6 0.8 1.2 11 0.3 1.4 15.5 410 57

5 2 1.5 1.6 0.8 1.4 18.5 0.3 1.6 23 840 159

5 2 1.5 1.6 0.8 1.4 18.5 0.3 1.6 23 840 159

12 2 0.75 1.15 0.8 1.6 24 0.3 1.8 29 1240 213

2 2 0.75 1.15 0.8 1.2 12.5 0.3 1.4 17 430 36

2 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18.5 500 64

2 2 0.75 1.15 0.8 1.2 12.5 0.3 1.4 17 430 36

2 3 0.75 1.15 0.8 1.3 14 0.3 1.4 18 490 49

2 3 1 1.3 0.8 1.3 14.5 0.3 1.5 19 530 65

2 3 1.5 1.6 0.8 1.3 15.5 0.3 1.5 20 600 89

3 3 1 1.3 0.8 1.3 15.5 0.3 1.5 20 630 97

3 3 1.5 1.6 0.8 1.4 16.5 0.3 1.5 21 730 134

3 2 1 1.3 0.8 1.3 14 0.3 1.4 18.5 520 71

3 2 1.5 1.6 0.8 1.3 15 0.3 1.5 19.5 600 96

12 2 1.5 1.6 0.8 1.8 27.5 0.45 2 33.5 1750 382

12 2 1.5 1.6 0.8 1.8 27.5 0.45 2 33.5 1750 382

20 2 1.5 1.6 0.8 2 34 0.45 2.3 41 2640 636

Number of

elements

No of cores in element

Cross section

core, mm²

Conductor Diameter,

mm

Insulation Thickness

mm

Thickness Inner

Sheath, mm

Approx Diameter

Inner Sheath,

mm

Diameter Braid

Wire, mm

Thickness Outer

Sheath, mm

Approx Overall

Diameter mm

Weight of Cable

Approx. (Kg/Km)

Copper content Approx. (kg/km)

Type Capacitance, approx. (nF/km)

Inductance, approx (mH/km)

Resistance at 20°C, max. (Ohm/km)

L/R ratio, (microH/Ohm)

Insulation resistance (Minimum

MOhmx km) Shielded pair 0,75 mm² 90 0,75 26,7 14 940 Shielded triple 0,75 mm² 90 0,75 26,7 14 940 Shielded quad 0,75 mm² 60 0,91 26,7 14 940 Shielded pair 1 mm² 100 0,73 20,0 18 840 Shielded triple 1 mm² 100 0,73 20,0 18 840 Shielded quad 1 mm² 70 0,95 20,0 18 840 Shielded pair 1,5 mm² 110 0,68 13,7 24,8 730 Shielded triple 1,5 mm² 110 0,68 13,7 24,8 730 Shielded quad 1,5 mm² 80 0,99 13,7 24,8 730 Shielded pair 2,5 mm² 120 0,70 7,56 46,3 620

Electrical values

350

Page 358: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

BFCU(I) 250V, Fire Resistant, Individual screened instrumentation

Ordering information Part number Description Sheath Colour Design standard UKOOA Code

840009 BFCU(I) 250V 1PAIR 0.75mm² GREY BS 7917 : 1999 GPF00 840010 BFCU(I) 250V 1QUAD 0.75mm² GREY BS 7917 : 1999 GPX00 840017 BFCU(I) 250V 1TRIP 0.75mm² GREY BS 7917 : 1999 GPR00 840018 BFCU(I) 250V 3TRIP 0.75mm² GREY BS 7917 : 1999 GPS00 840019 BFCU(I) 250V 7TRIP 0.75mm² GREY BS 7917 : 1999 GPT00 840020 BFCU(I) 250V 12TRIP 0.75mm² GREY BS 7917 : 1999 GPU00 840029 BFCU(I) 250V 1PAIR 0.75mm² BLUE BS 7917 : 1999 GMF00 840030 BFCU(I) 250V 1QUAD 0.75mm² BLUE BS 7917 : 1999 GMX00 840037 BFCU(I) 250V 1TRIP 0.75mm² BLUE BS 7917 : 1999 GMR00 840038 BFCU(I) 250V 3TRIP 0.75mm² BLUE BS 7917 : 1999 GMS00 840039 BFCU(I) 250V 7TRIP 0.75mm² BLUE BS 7917 : 1999 GMT00 840040 BFCU(I) 250V 12TRIP 0.75mm² BLUE BS 7917 : 1999 GMU00 840041 BFCU(I) 250V 1PAIR 1.5mm² GREY BS 6883 : 1991 GPF02 840042 BFCU(I) 250V 1QUAD 1.5mm² GREY BS 6883 : 1991 GPX02 840045 BFCU(I) 250V 1PAIR 1.5mm² BLUE BS 6883 : 1991 GMF02 840046 BFCU(I) 250V 1QUAD 1.5mm² BLUE BS 6883 : 1991 GMX02 840087 BFCU(I) 250V 1TRIP 1.5mm² BLUE BS 6883 : 1991 GMR02 840089 BFCU(I) 250V 1PAIR 1mm² BLUE BS 7917 : 1999 GMF01 840123 BFCU(I) 250V 1PAIR 1mm² GREY BS 7917 : 1999 GPF01 840125 BFCU(I) 250V 7PAIR 0.75mm² GREY BS 7917 : 1999 GPJ00 840127 BFCU(I) 250V 1TRIP 1mm² GREY BS 7917 : 1999 GPR01 840131 BFCU(I) 250V 1TRIP 1.5mm² GREY BS 6883 : 1991 GPR02 840138 BFCU(I) 250V 7PAIR 1.5mm² GREY BS 6883 : 1991 GPJ02 840139 BFCU(I) 250V 7PAIR 1.5mm² BLUE BS 6883 : 1991 GMJ02 840140 BFCU(I) 250V 2PAIR 1.5mm² BLUE BS 6883 : 1991 - 840141 BFCU(I) 250V 1QUAD 1mm² GREY BS 7917 : 1999 GPX01 840142 BFCU(I) 250V 1QUAD 1mm² BLUE BS 7917 : 1999 GMX01 840157 BFCU(I) 250V 1TRIP 1mm² BLUE BS 7917 : 1999 GMR01 840175 BFCU(I) 250V 7PAIR 0.75mm² BLUE BS 7917 : 1999 GMJ00 840200 BFCU(I) 250V 20PAIR 0.75mm² GREY BS 7917 : 1999 GPL00 840202 BFCU(I) 250V 1QUAD 2.5mm² GREY BS 6883 : 1991 GPX03 840217 BFCU(I) 250V 3PAIR 0.75mm² BLUE BS 7917 : 1999 GMH00 840218 BFCU(I) 250V 3PAIR 1mm² GREY BS 7917 : 1999 GPH01 840240 BFCU(I) 250V 3PAIR 0.75mm² GREY BS 7917 : 1999 GPH00 840253 BFCU(I) 250V 12PAIR 0.75mm² GREY BS 7917 : 1999 GPK00 840254 BFCU(I) 250V 20PAIR 0.75mm² BLUE BS 7917 : 1999 GML00 840267 BFCU(I) 250V 5PAIR 0.75mm² BLUE BS 6883 : 1991 - 840268 BFCU(I) 250V 3PAIR 1.5mm² GREY BS 6883 : 1991 GPH02 840271 BFCU(I) 250V 5PAIR 0.75mm² GREY BS 6883 : 1991 - 840280 BFCU(I) 250V 20PAIR 1.5mm² GREY BS 6883 : 1991 GPL02 840281 BFCU(I) 250V 1QUAD 1.5mm² GREY BS 6883 : 1991 GPX02 840290 BFCU(I) 250V 5PAIR 1.5mm² GREY BS 6883 : 1991 - 840291 BFCU(I) 250V 5PAIR 1.5mm² BLUE BS 6883 : 1991 - 351

Page 359: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

BFCU(I) 250V, Fire Resistant, Individual screened instrumentation

Part number Description Sheath Colour Design standard UKOOA Code

840292 BFCU(I) 250V 12PAIR 0.75mm² BLUE BS 7917 : 1999 GMK00

840314 BFCU(I) 250V 2PAIR 0.75mm² GREY BS 6883 : 1991 -

840315 BFCU(I) 250V 2PAIR 1.5mm² GREY BS 6883 : 1991 -

840316 BFCU(I) 250V 2PAIR 0.75mm² BLUE BS 6883 : 1991 -

840322 BFCU(I) 250V 2TRIP 0.75mm² GREY BS 6883 : 1991 -

840323 BFCU(I) 250V 2TRIP 1mm² GREY BS 6883 : 1991 -

840324 BFCU(I) 250V 2TRIP 1.5mm² GREY BS 6883 : 1991 -

840325 BFCU(I) 250V 3TRIP 1mm² GREY BS 7917 : 1999 GPS01

840326 BFCU(I) 250V 3TRIP 1.5mm² GREY BS 6883 : 1991 GPS02

840327 BFCU(I) 250V 3PAIR 1mm² BLUE BS 7917 : 1999 GMH01

840328 BFCU(I) 250V 3PAIR 1.5mm² BLUE BS 6883 : 1991 GMH02

840329 BFCU(I) 250V 12PAIR 1.5mm² GREY BS 6883 : 1991 GPK02

840330 BFCU(I) 250V 12PAIR 1.5mm² BLUE BS 6883 : 1991 GMK02

840331 BFCU(I) 250V 20PAIR 1.5mm² BLUE BS 6883 : 1991 GML02

Minimum Bending Radius during Installation

Minimum Bending Radius Fixed Installed

Maximum Tensile Load During Installation

Minimum Installation Temperature

10 x D 8 x D 50 N /mm² -20°C

Installation recommendations

352

Page 360: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

RFCU 0.6/1KV Power, Control or Lighting cable

Flame retardant halogen-free power cable. Enhanced oil-resistance.

RFCU 0.6/1kV

Operating temperature : 90°C

Operating Voltage : 0,6/1kV

Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606.

Application Standards applied BS6883 / UKOOA - Design

BS6360 class 2 - Conductor

BS7655 section 1.2 - Insulation

BS7655 section 2.6 - Sheath

IEC 60332-1 - Flame Retardant

IEC60332-3-22 - Flame retardant

IEC60754-1,2 - Halogen Free

IEC 61034-1,2 - Low Smoke

Code Letter

Conductor Tinned stranded circular copper, BS 6360, class 2

Insulation R EP-rubber, GP4 to BS 7655: section 1.2

Lay up / Shielding Cores laid up in concentric layers

Inner covering F Flame retardant and halogen-free thermoset compound

Tape over inner covering PET tape + rubberized Polyamide tape

Armour/screen C Galvanized steel wire braid

Tape over armour/screen PET tape + rubberised Polyamide tape

Outer sheath U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6

Marking text

"metre mark" "year" "DRAKA" "RFCU" "UKOOA code" "600/1000V" "number of cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable actually supplied)

Outer sheath colour Black

Construction

Core identification All cores are offwhite with black numbers No 1,2,3…….

www.drakaMOG.com Information subject to change without notice

353

Page 361: Prysmian Draka - Marine & Offshore LV HV Cables

RFCU 0.6/1KV Power, Control or Lighting cable

Marine, Oil & Gas International

Range and dimensions

Number of cores

Cross section

core, mm²

Conductor Diameter,

mm

Insulation Thickness,

mm

Thickness Inner

Sheath, mm

Approx Diameter

inner Sheath,

mm

Diameter Braid Wire,

mm

Thickness Outer

Sheath, mm

Approx Overall

Diameter, mm

Weight of Cable

Approx. (Kg/Km)

Copper content Approx. (kg/km)

2 1.5 1.6 0.8 1.1 8.5 0.3 1.2 12.5 280 28 2 2.5 2.0 0.8 1.1 9.5 0.3 1.2 13.5 320 46 2 4 2.55 1.0 1.2 11.5 0.3 1.3 15.5 440 74 3 1.5 1.6 0.8 1.1 9 0.3 1.2 13 310 42 3 2.5 2.0 0.8 1.1 10 0.3 1.3 14 360 69 3 4 2.55 1.0 1.2 12.5 0.3 1.3 16.5 490 110 3 6 3.15 1.0 1.2 13.5 0.3 1.4 18 610 164 3 16 5.15 1.0 1.4 18.5 0.3 1.6 23 1120 434 3 35 7.65 1.2 1.7 25.5 0.45 1.9 31 2150 927 3 70 10.85 1.4 2 34 0.45 2.2 40 3770 1863 4 1.5 1.6 0.8 1.1 10 0.3 1.3 14 350 56 4 4 2.55 1.0 1.2 13.5 0.3 1.4 18 590 147 4 6 3.15 1.0 1.3 15 0.3 1.5 19.5 740 218 4 16 5.15 1.0 1.5 20.5 0.3 1.7 25.5 1390 578 4 25 6.45 1.2 1.7 25 0.45 1.9 31 2130 917 4 35 7.65 1.2 1.8 28 0.45 2 34 2620 1236 7 2.5 2.0 0.8 1.2 13.5 0.3 1.4 18.5 590 161 12 2.5 2.0 0.8 1.4 18 0.3 1.6 22.5 900 275 19 2.5 2.0 0.8 1.5 21 0.3 1.7 27 1240 435 4 70 10.85 1.4 2.1 38 0.45 2.4 44 4670 2484 3 10 4.05 1.0 1.3 16 0.3 1.5 20.5 830 271 3 25 6.45 1.2 1.6 22.5 0.3 1.8 28 1640 688 4 10 4.05 1.0 1.4 17.5 0.3 1.6 22.5 1000 361 19 1.5 1.6 0.8 1.4 19 0.3 1.6 24 960 264 4 50 9.0 1.4 1.9 33 0.45 2.2 39.5 3480 1716 4 95 12.60 1.6 2.3 43.5 0.45 2.6 50.5 6080 3351 2 6 3.15 1.0 1.2 13 0.3 1.4 17 540 109 4 6 3.15 1.0 1.3 15 0.3 1.5 19.5 740 218 37 2.5 2.0 0.8 1.8 29 0.45 2 35 2270 847 2 16 5.15 1.0 1.4 17.5 0.3 1.5 22 940 289 27 2.5 2.0 0.8 1.7 25.5 0.45 1.9 31.5 1820 618 7 1.5 1.6 0.8 1.2 12 0.3 1.3 17 470 98 12 1.5 1.6 0.8 1.3 16 0.3 1.5 20.5 710 167 2 35 7.65 1.2 1.6 23.5 0.3 1.8 28.5 1650 618 3 50 9.0 1.4 1.8 29.5 0.45 2 35 2830 1287

4 2.5 2.0 0.8 1.1 11 0.3 1.3 15 420 92

3 95 12.60 1.6 2.2 39 0.45 2.4 45 4860 2513 5 1.5 1.6 0.8 1.1 11 0.3 1.3 15 440 83

www.drakaMOG.com Information subject to change without notice

354

Page 362: Prysmian Draka - Marine & Offshore LV HV Cables

RFCU 0.6/1KV Power, Control or Lighting cable

Marine, Oil & Gas International

Ordering information Part number Description Sheath Colour Design standard UKOOA Code

840049 RFCU 0.6/1kV 2X 1.5mm² BLACK BS 6883 : 1999 WB202

840050 RFCU 0.6/1kV 2X 2.5mm² BLACK BS 6883 : 1999 WB203

840051 RFCU 0.6/1kV 2X 4mm² BLACK BS 6883 : 1999 WB204

840052 RFCU 0.6/1kV 3X 1.5mm² BLACK BS 6883 : 1999 WB302

840053 RFCU 0.6/1kV 3X 2.5mm² BLACK BS 6883 : 1999 WB303

840054 RFCU 0.6/1kV 3X 4mm² BLACK BS 6883 : 1999 WB304

840055 RFCU 0.6/1kV 3X 6mm² BLACK BS 6883 : 1999 WB306

840056 RFCU 0.6/1kV 3X 16mm² BLACK BS 6883 : 1999 WB316

840057 RFCU 0.6/1kV 3X 35mm² BLACK BS 6883 : 1999 WB335

840058 RFCU 0.6/1kV 3X 70mm² BLACK BS 6883 : 1999 WB370

840059 RFCU 0.6/1kV 4X 1.5mm² BLACK BS 6883 : 1999 WB402

840061 RFCU 0.6/1kV 4X 4mm² BLACK BS 6883 : 1999 WB404

840062 RFCU 0.6/1kV 4X 6mm² BLACK BS 6883 : 1999 WB406

840063 RFCU 0.6/1kV 4X 16mm² BLACK BS 6883 : 1999 WB416

840064 RFCU 0.6/1kV 4X 25mm² BLACK BS 6883 : 1999 WB425

840065 RFCU 0.6/1kV 4X 35mm² BLACK BS 6883 : 1999 WB435

840068 RFCU 0.6/1kV 7X 2.5mm² BLACK BS 6883 : 1999 WB703

840070 RFCU 0.6/1kV 12X 2.5mm² BLACK BS 6883 : 1999 WBA03

840071 RFCU 0.6/1kV 19X 2.5mm² BLACK BS 6883 : 1999 WBB03

840088 RFCU 0.6/1kV 4X 70mm² BLACK BS 6883 : 1999 WB470

840154 RFCU 0.6/1kV 3X 10mm² BLACK BS 6883 : 1999 WB310

840158 RFCU 0.6/1kV 3X 25mm² BLACK BS 6883 : 1999 WB325

840159 RFCU 0.6/1kV 4X 10mm² BLACK BS 6883 : 1999 WB410

840160 RFCU 0.6/1kV 19X 1.5mm² BLACK BS 6883 : 1999 WBB02

840166 RFCU 0.6/1kV 4X 50mm² BLACK BS 6883 : 1999 WB450

840242 RFCU 0.6/1kV 4X 95mm² BLACK BS 6883 : 1999 WB495

840245 RFCU 0.6/1kV 2X 6mm² BLACK BS 6883 : 1999 WB206

840246 RFCU 0.6/1kV 4X 6mm² BLACK BS 6883 : 1999 WB406

840256 RFCU 0.6/1kV 37X 2.5mm² BLACK BS 6883 : 1991 WBD03

840258 RFCU 0.6/1kV 2X 16mm² BLACK BS 6883 : 1999 WB216

840262 RFCU 0.6/1kV 27X 2.5mm² BLACK BS 6883 : 1991 WBC03

840263 RFCU 0.6/1kV 7X 1.5mm² BLACK BS 6883 : 1999 WB702

840264 RFCU 0.6/1kV 12X 1.5mm² BLACK BS 6883 : 1999 WBA02

840269 RFCU 0.6/1kV 2X 35mm² BLACK BS 6883 : 1999 WB235

840283 RFCU 0.6/1kV 3X 50mm² BLACK BS 6883 : 1999 WB350

840284 RFCU 0.6/1kV 4X 2.5mm² BLACK BS 6883 : 1999 WB403

840311 RFCU 0.6/1kV 3X 95mm² BLACK BS 6883 : 1999 WB395 840338 RFCU 0.6/1kV 5X 1.5mm² BLACK BS 6883 : 1999 -

www.drakaMOG.com Information subject to change without notice

355

Page 363: Prysmian Draka - Marine & Offshore LV HV Cables

RFCU 0.6/1KV Power, Control or Lighting cable

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

Electrical values Number of

cores Cross section

core, mm² Max. conductor

resistance at 20°C, Ohm/km

Max. conductor resistance at

90°C, Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Current rating IEC 60092-352

Table B.4, Ampere

Short circuit rating 1 second, Ampere

2 1.5 12.2 15.6 0.103 0.123 20 210 2 2.5 7.56 9.64 0.096 0.115 26 350 2 4 4.7 5.99 0.096 0.115 34 560 3 1.5 12.2 15.6 0.103 0.123 16 210 3 2.5 7.56 9.64 0.096 0.115 21 350 3 4 4.7 5.99 0.096 0.115 28 560 3 6 3.11 3.97 0.090 0.108 36 840 3 16 1.16 1.48 0.080 0.096 67 2240 3 35 0.529 0.675 0.076 0.092 110 4900 3 70 0.27 0.344 0.074 0.088 169 9800 4 1.5 12.2 15.6 0.103 0.123 16 210 4 4 4.7 5.99 0.096 0.115 28 560 4 6 3.11 3.97 0.090 0.108 36 840 4 16 1.16 1.48 0.080 0.096 67 2240 4 25 0.734 0.936 0.079 0.095 89 3500 4 35 0.529 0.675 0.076 0.092 110 4900 7 2.5 7.56 9.64 0.096 0.115 15.5 350

12 2.5 7.56 9.64 0.096 0.115 13 350 19 2.5 7.56 9.64 0.096 0.115 11 350 4 70 0.27 0.344 0.074 0.088 169 9800 3 10 1.84 2.35 0.084 0.101 50 1400 3 25 0.734 0.936 0.079 0.095 89 3500 4 10 1.84 2.35 0.084 0.101 50 1400

19 1.5 12.2 15.6 0.103 0.123 8.5 210 4 50 0.391 0.499 0.076 0.092 137 7000 4 95 0.195 0.249 0.073 0.088 205 13300 2 6 3.11 3.97 0.090 0.108 44 840 4 6 3.11 3.97 0.090 0.108 36 840

37 2.5 7.56 9.64 0.096 0.115 9 350 2 16 1.16 1.48 0.080 0.096 80 2240

27 2.5 7.56 9.64 0.096 0.115 10 350 7 1.5 12.2 15.6 0.103 0.123 12 210

12 1.5 12.2 15.6 0.103 0.123 10 210 2 35 0.529 0.675 0.076 0.092 133 4900 3 50 0.391 0.499 0.076 0.092 137 7000 4 2.5 7.56 9.64 0.096 0.115 21 350 3 95 0.195 0.249 0.073 0.088 205 13300 5 1.5 12.2 15.6 0.103 0.123 13.5 210

Minimum Bending Radius during Installation

Minimum Bending Radius Fixed Installed

Maximum Tensile Load During Installation

Minimum Installation Temperature

8 x D OD < 25 mm - 4 x D, OD > 25 mm - 6 x D 50 N /mm² -20°C

Installation recommendations

Ambient Temp °C 35 40 45 50 55 60 65 70 75 80

Rating factor 1.11 1.05 1.00 0.94 0.88 0.82 0.75 0.67 0.50 0.47

Ambient temperature correction factors

356

Page 364: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

RFCU(C) 250V, Collective screened instrumentation

Flame retardant halogen-free instrumentation cable. Enhanced oil-resistance.

RFCU(C) 250V

Operating temperature : 90°C

Operating Voltage : 250V

Fixed installation for instrumentation, communication, control and alarm systems in both EX– and safe areas. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606.

Application Standards applied BS6883 / UKOOA - Design

BS6360 class 2 or 5 - Conductor

BS7655 section 1.2 - Insulation

BS7655 section 2.6 - Sheath

IEC 60332-1 - Flame Retardant

IEC60332-3-22 - Flame retardant

IEC60754-1,2 - Halogen Free

IEC 61034-1,2 - Low Smoke

Code Letter

Conductor Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5) Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)

Insulation R EP-rubber, GP4 to BS 7655: section 1.2

Pair/Triple/Quad twisting

Colour coded cores twisted together to form a pair, triple or quad, wrapped with polyester tape. Pairs, triples or quads are laid up, collectively screened with aluminium backed polyester tape with tinned copper drain wire. Pairs, triples, or quads are identified by numbers printed directly on the insulated conductors.

Inner covering F Flame retardant and halogen-free thermoset compound

Tape over inner covering PET tape + rubberized Polyamide tape

Armour/screen C Galvanized steel wire braid

Tape over armour/screen PET tape + rubberised Polyamide tape

Outer sheath U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6

Marking text

"metre mark" "year" "DRAKA" "RFCU(C)" "UKOOA code" "150/250V" "number of pair, triples or quads" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable actually supplied)

Outer sheath colour Grey or Blue

Construction

Core identification Pair - Black—White, numbered 1-1, 2-2, 3-3 …… Triple— Black—White—Red, numbered 1-1-1, 2-2-2, 3-3-3 …… Quad— Black—White—Red—Blue, numbered 1-1-1-1, 2-2-2-2 ….. Each core is identified by contrasting numerals & words repeated along the whole length of the cable.

www.drakaMOG.com Information subject to change without notice

357

Page 365: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

RFCU(C) 250V, Collective screened instrumentation

Range and dimensions

Number of

elements

No of cores in element

Cross section

core, mm²

Conductor Diameter,

mm

Insulation Thickness

mm

Thickness Inner

Sheath, mm

Diameter Inner

Sheath, mm

Diameter Braid

Wire, mm

Thickness Outer

Sheath, mm

Approx Overall

Diameter , mm

Weight of Cable

Approx. (Kg/Km)

Copper content Approx. (kg/km)

3 2 0.75 1.15 0.8 1.2 12 0.3 1.4 16.5 420 45

7 2 0.75 1.15 0.8 1.4 16.5 0.3 1.5 21 660 97

12 2 0.75 1.15 0.8 1.6 21.5 0.3 1.7 26 1000 164

27 2 0.75 1.15 0.8 1.9 29 0.45 2.2 35.5 1980 359

3 2 0.75 1.15 0.8 1.2 12 0.3 1.4 16.5 420 45

7 2 0.75 1.15 0.8 1.4 16.5 0.3 1.5 21 660 97

12 2 0.75 1.15 0.8 1.6 21.5 0.3 1.7 26 1000 164

19 2 0.75 1.15 0.8 1.7 24.5 0.45 1.9 30 1460 257

27 2 0.75 1.15 0.8 1.9 29 0.45 2.2 35.5 1980 359

2 2 1 1.3 0.8 1.2 12 0.3 1.4 16.5 400 41

20 2 0.75 1.15 0.8 1.8 25.5 0.45 2 31.5 1570 271

20 2 0.75 1.15 0.8 1.8 25.5 0.45 2 31.5 1570 271

7 2 1.5 1.6 0.8 1.4 18.5 0.3 1.6 23 850 183

12 2 1.5 1.6 0.8 1.7 24.5 0.45 1.9 30 1470 309

20 2 1.5 1.6 0.8 1.9 29 0.45 2.2 35.5 2130 511

27 2 1.5 1.6 0.8 2.1 33.5 0.45 2.4 40 2650 687

7 3 0.75 1.15 0.8 1.4 18 0.3 1.6 22.5 820 144

12 3 0.75 1.15 0.8 1.7 24 0.3 1.9 29 1290 244

3 3 0.75 1.15 0.8 1.3 13.5 0.3 1.4 18 510 65

3 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18 520 82

3 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18 520 82

3 2 1 1.3 0.8 1.2 12.5 0.3 1.4 17 460 58

3 3 0.75 1.15 0.8 1.3 13.5 0.3 1.4 18 510 65

12 3 1.5 1.6 0.8 1.8 27.5 0.45 2 33.5 1840 461

3 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18 520 82

5 2 1.5 1.6 0.8 1.4 17 0.3 1.6 21.5 730 132

2 2 0.75 1.15 0.8 1.2 11.5 0.3 1.3 15.5 370 31

2 2 1.5 1.6 0.8 1.2 13 0.3 1.4 17 450 57

5 2 0.75 1.15 0.8 1.3 15 0.3 1.5 19.5 570 71

358

Page 366: Prysmian Draka - Marine & Offshore LV HV Cables

RFCU(C) 250V, Collective screened instrumentation

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

Electrical values

Type Capacitance, approx. (nF/km)

Inductance, approx, (mH/

km)

Resistance at 20°C, max. (Ohm/km)

L/R ratio, (microH/Ohm)

Insulation resistance (Minimum

Mohm x km) Unshielded pair 0,75 mm² 80 0,75 26,7 14 940 Unshielded triple 0,75 mm² 80 0,75 26,7 14 940 Unshielded pair 1,0 mm² 85 0,73 20,0 18 840 Unshielded triple 1,0 mm² 85 0,73 20,0 18 840 Unshielded pair 1,5 mm² 90 0,68 13,7 24,8 730 Unshielded triple 1,5 mm² 90 0,68 13,7 24,8 730 Unshielded pair 2,5 mm² 90 0,70 7,56 46,3 620 Unshielded triple 2,5 mm² 90 0,70 7,56 46,3 620

Ordering information Part number Description Sheath Colour Design standard UKOOA Code

840003 RFCU(C) 250V 3PAIR 0.75mm² GREY BS 6883 : 1999 KJH00 840004 RFCU(C) 250V 7PAIR 0.75mm² GREY BS 6883 : 1999 KJJ00 840005 RFCU(C) 250V 12PAIR 0.75mm² GREY BS 6883 : 1999 KJK00 840007 RFCU(C) 250V 27PAIR 0.75mm² GREY BS 6883 : 1999 KJM00 840023 RFCU(C) 250V 3PAIR 0.75mm² BLUE BS 6883 : 1999 KGH00 840024 RFCU(C) 250V 7PAIR 0.75mm² BLUE BS 6883 : 1999 KGJ00 840025 RFCU(C) 250V 12PAIR 0.75mm² BLUE BS 6883 : 1999 KGK00 840026 RFCU(C) 250V 19PAIR 0.75mm² BLUE BS 6883 : 1991 - 840027 RFCU(C) 250V 27PAIR 0.75mm² BLUE BS 6883 : 1999 KGM00 840117 RFCU(C) 250V 2PAIR 1mm² GREY BS 6883 : 1991 - 840128 RFCU(C) 250V 20PAIR 0.75mm² GREY BS 6883 : 1999 KJL00 840156 RFCU(C) 250V 20PAIR 0.75mm² BLUE BS 6883 : 1999 KGL00 840176 RFCU(C) 250V 7PAIR 1.5mm² GREY BS 6883 : 1991 KJJ02 840177 RFCU(C) 250V 12PAIR 1.5mm² GREY BS 6883 : 1991 KJK02 840178 RFCU(C) 250V 20PAIR 1.5mm² GREY BS 6883 : 1991 KJL02 840179 RFCU(C) 250V 27PAIR 1.5mm² GREY BS 6883 : 1991 KJM02 840222 RFCU(C) 250V 7TRIP 0.75mm² BLUE BS 6883 : 1999 KGT00 840223 RFCU(C) 250V 12TRIP 0.75mm² BLUE BS 6883 : 1999 KGU00 840231 RFCU(C) 250V 3TRIP 0.75mm² GREY BS 6883 : 1999 KJS00 840236 RFCU(C) 250V 3PAIR 1.5mm² BLUE BS 6883 : 1991 KGH02 840237 RFCU(C) 250V 3PAIR 1.5mm² GREY BS 6883 : 1991 KJH02 840241 RFCU(C) 250V 3PAIR 1mm² GREY BS 6883 : 1999 KJH01 840274 RFCU(C) 250V 3TRIP 0.75mm² GREY BS 6883 : 1999 KJS00 840277 RFCU(C) 250V 12TRIP 1.5mm² BLUE BS 6883 : 1991 KGU02 840294 RFCU(C) 250V 3PAIR 1.5mm² GREY BS 6883 : 1991 KJH02 840295 RFCU(C) 250V 5PAIR 1.5mm² GREY BS 6883 : 1991 - 840332 RFCU(C) 250V 2PAIR 0.75mm² GREY BS 6883 : 1991 - 840333 RFCU(C) 250V 2PAIR 1.5mm² GREY BS 6883 : 1991 - 840334 RFCU(C) 250V 5PAIR 0.75mm² GREY BS 6883 : 1991 -

359

Page 367: Prysmian Draka - Marine & Offshore LV HV Cables

www.drakaMOG.com Information subject to change without notice

Installation recommendations Minimum Bending Radius during

Installation Minimum Bending Radius Fixed

Installed Maximum Tensile Load During

Installation Minimum Installation

Temperature

10 x D 8 x D 50 N /mm² -20°C

Marine, Oil & Gas International

RFCU(C) 250V, Collective screened instrumentation

360

Page 368: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

RFCU(I) 250V, Individual screened instrumentation

Flame retardant halogen-free instrumentation cable. Enhanced oil-resistance.

RFCU(I) 250V

Operating temperature : 90°C

Operating Voltage : 250V

Fixed installation for instrumentation, communication, control and alarm systems in both EX– and safe areas. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606.

Application Standards applied BS6883 / UKOOA - Design

BS6360 class 2 or 5 - Conductor

BS7655 section 1.2 - Insulation

BS7655 section 2.6 - Sheath

IEC 60332-1 - Flame Retardant

IEC60332-3-22 - Flame retardant

IEC60754-1,2 - Halogen Free

IEC 61034-1,2 - Low Smoke

Code Letter

Conductor Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5) Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)

Insulation R EP-rubber, GP4 to BS 7655: section 1.2

Pair/Triple/Quad twisting / lay up

Colour coded cores twisted together to form a pair, triple or quad, which is individually screened with aluminium backed polyester tape with a tinned copper drain wire. Each pair, triple or quad is wrapped with polyester tape to prevent electrical contact with adjacent pairs, triples or quads. Individually shielded pairs, triples or quads are laid up in concentric layers and wrapped with a PETP tape. Pairs, triples, or quads are identified by numbers printed directly on the insulated conductors.

Inner covering F Flame retardant and halogen-free thermoset compound

Tape over inner covering PET tape + rubberized Polyamide tape

Armour/screen C Galvanized steel wire braid

Tape over armour/screen PET tape + rubberised Polyamide tape

Outer sheath U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6

Marking text

"metre mark" "year" "DRAKA" "RFCU(I)" "UKOOA code" "150/250V" "number of pair, triples or quads" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable actually supplied)

Outer sheath colour Grey or Blue

Construction

Core identification Pair - Black—White, numbered 1-1, 2-2, 3-3 …… Triple— Black—White—Red, numbered 1-1-1, 2-2-2, 3-3-3 …… Quad— Black—White—Red—Blue, numbered 1-1-1-1, 2-2-2-2 ….. Each core is identified by contrasting numerals & words repeated along the whole length of the cable.

www.drakaMOG.com Information subject to change without notice

361

Page 369: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

RFCU(I) 250V, Individual screened instrumentation

Range and dimensions

Number of

elements

No of cores in element

Cross section

core, mm²

Conductor Diameter,

mm

Insulation Thickness

mm

Thickness Inner

Sheath, mm

Approx Diameter

Inner Sheath,

mm

Diameter Braid

Wire, mm

Thickness Outer

Sheath, mm

Approx Overall

Diameter mm

Weight of Cable

Approx. (Kg/Km)

Copper content Approx. (kg/km)

1 2 0.75 1.15 0.8 1 7.5 0.3 1.2 11.5 230 18

1 4 0.75 1.15 0.8 1.2 9 0.3 1.3 13.5 310 31

1 2 0.75 1.15 0.8 1 7.5 0.3 1.2 11.5 230 18

1 4 0.75 1.15 0.8 1.2 9 0.3 1.3 13.5 310 31

1 2 1 1.3 0.8 1 8 0.3 1.2 12 240 24

1 2 1 1.3 0.8 1 8 0.3 1.2 12 240 24

1 4 1 1.3 0.8 1.2 9.5 0.3 1.4 14 340 41

3 2 1 1.3 0.8 1.3 13 0.3 1.4 17 490 71

1 3 1 1.3 0.8 1.1 8.5 0.3 1.2 12.5 285 32

7 3 0.75 1.15 0.8 1.5 18.5 0.3 1.7 23.5 900 170

12 3 0.75 1.15 0.8 1.7 25 0.45 2 31 1530 293

7 2 0.75 1.15 0.8 1.4 16.5 0.3 1.6 21 720 124

7 2 0.75 1.15 0.8 1.4 16.5 0.3 1.6 21 720 124

12 2 0.75 1.15 0.8 1.6 22 0.3 1.8 27 1110 212

12 2 0.75 1.15 0.8 1.6 22 0.3 1.8 27 1110 212

3 3 0.75 1.15 0.8 1.3 14 0.3 1.5 18.5 530 73

3 2 0.75 1.15 0.8 1.2 12 0.3 1.4 16.5 430 53

3 2 0.75 1.15 0.8 1.2 12 0.3 1.4 16.5 430 53

20 2 1.5 1.6 0.8 2 31.5 0.45 2.3 38 2430 635

19 2 0.75 1.15 0.8 1.8 26 0.45 2 32 1660 336

12 3 0.75 1.15 0.8 1.7 25 0.45 2 31 1530 293

7 3 0.75 1.15 0.8 1.5 18.5 0.3 1.7 23.5 900 170

3 2 1.5 1.6 0.8 1.3 14 0.3 1.5 18.5 560 95

3 3 0.75 1.15 0.8 1.3 14 0.3 1.5 18.5 530 73

3 2 1.5 1.6 0.8 1.3 14 0.3 1.5 18.5 560 95

1 2 1.5 1.6 0.8 1.1 8.5 0.3 1.2 12.5 290 32

1 3 1.5 1.6 0.8 1.1 9 0.3 1.2 13 320 45

1 3 0.75 1.15 0.8 1 8 0.3 1.2 12 245 25

1 4 1 1.3 0.8 1.2 9.5 0.3 1.4 14 340 41

1 4 1.5 1.6 0.8 1.2 10 0.3 1.4 14.5 370 57 1 3 1.5 1.6 0.8 1.1 9 0.3 1.2 13 320 45

362

Page 370: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

RFCU(I) 250V, Individual screened instrumentation

Electrical values

Type Capacitance, approx. (nF/km)

Inductance, approx (mH/

km)

Resistance at 20°C, max. (Ohm/km)

L/R ratio, (microH/Ohm)

Insulation resistance

(Minimum MOhmx km)

Shielded pair 0,75 mm² 90 0,75 26,7 14 940 Shielded triple 0,75 mm² 90 0,75 26,7 14 940 Shielded quad 0,75 mm² 60 0,91 26,7 14 940 Shielded pair 1 mm² 100 0,73 20,0 18 840 Shielded triple 1 mm² 100 0,73 20,0 18 840 Shielded quad 1 mm² 70 0,95 20,0 18 840 Shielded pair 1,5 mm² 110 0,68 13,7 24,8 730 Shielded triple 1,5 mm² 110 0,68 13,7 24,8 730 Shielded quad 1,5 mm² 80 0,99 13,7 24,8 730 Shielded pair 2,5 mm² 120 0,70 7,56 46,3 620

Part number Description Sheath Colour Design standard UKOOA Code 840001 RFCU(I) 250V 1PAIR 0.75mm² GREY BS 6883 : 1999 KKF00 840002 RFCU(I) 250V 1QUAD 0.75mm² GREY BS 6883 : 1999 KKX00 840021 RFCU(I) 250V 1PAIR 0.75mm² BLUE BS 6883 : 1999 KHF00 840022 RFCU(I) 250V 1QUAD 0.75mm² BLUE BS 6883 : 1999 KHX00 840094 RFCU(I) 250V 1PAIR 1mm² GREY BS 6883 : 1999 KKF01 840095 RFCU(I) 250V 1PAIR 1mm² BLUE BS 6883 : 1999 KHF01 840096 RFCU(I) 250V 1QUAD 1mm² BLUE BS 6883 : 1999 KHX01 840100 RFCU(I) 250V 3PAIR 1mm² BLUE BS 6883 : 1999 KHH01 840121 RFCU(I) 250V 1TRIP 1mm² GREY BS 6883 : 1999 KKR01 840211 RFCU(I) 250V 7TRIP 0.75mm² BLUE BS 6883 : 1999 KHT00 840212 RFCU(I) 250V 12TRIP 0.75mm² BLUE BS 6883 : 1999 KHU00 840214 RFCU(I) 250V 7PAIR 0.75mm² GREY BS 6883 : 1999 KKJ00 840215 RFCU(I) 250V 7PAIR 0.75mm² BLUE BS 6883 : 1999 KHJ00 840216 RFCU(I) 250V 12PAIR 0.75mm² GREY BS 6883 : 1999 KKK00 840221 RFCU(I) 250V 12PAIR 0.75mm² BLUE BS 6883 : 1999 KHK00 840224 RFCU(I) 250V 3TRIP 0.75mm² BLUE BS 6883 : 1999 KHS00 840226 RFCU(I) 250V 3PAIR 0.75mm² GREY BS 6883 : 1999 KKH00 840227 RFCU(I) 250V 3PAIR 0.75mm² BLUE BS 6883 : 1999 KHH00 840235 RFCU(I) 250V 20PAIR 1.5mm² GREY BS 6883 : 1991 KKL02 840238 RFCU(I) 250V 19PAIR 0.75mm² BLUE BS 6883 : 1991 - 840239 RFCU(I) 250V 12TRIP 0.75mm² GREY BS 6883 : 1999 KKU00 840272 RFCU(I) 250V 7TRIP 0.75mm² GREY BS 6883 : 1999 KKT00 840275 RFCU(I) 250V 3PAIR 1.5mm² GREY BS 6883 : 1991 KKH02 840276 RFCU(I) 250V 3TRIP 0.75mm² GREY BS 6883 : 1999 KKS00 840278 RFCU(I) 250V 3PAIR 1.5mm² BLUE BS 6883 : 1991 KHH02 840293 RFCU(I) 250V 1PAIR 1.5mm² GREY BS 6883 : 1991 KKF02 840296 RFCU(I) 250V 1TRIP 1.5mm² GREY BS 6883 : 1991 KKR02 840335 RFCU(I) 250V 1TRIP 0.75mm² GREY BS 6883 : 1999 KKR00 840336 RFCU(I) 250V 1QUAD 1mm² GREY BS 6883 : 1999 KKX01 840337 RFCU(I) 250V 1QUAD 1.5mm² GREY BS 6883 : 1991 KKX02 840339 RFCU(I) 250V 1TRIP 1.5mm² BLUE BS 6883 : 1991 KHR02

Ordering information

363

Page 371: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

www.drakaMOG.com Information subject to change without notice

RFCU(I) 250V, Individual screened instrumentation

Minimum Bending Radius during Installation

Minimum Bending Radius Fixed Installed

Maximum Tensile Load During Installation

Minimum Installation Temperature

10 x D 8 x D 50 N /mm² -20°C

Installation recommendations

364

Page 372: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

RU 0.6/1KV Unarmoured power cable

Flame retardant halogen-free power cable. Enhanced oil-resistance.

RU 0.6/1kV

Operating temperature : 90°C

Operating Voltage : 0.6/1kV

Unarmoured cable for fixed installation where cable protection is not required. Power, control and lighting in safe areas. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606.

Application Standards applied BS6883 - Design

BS6360 class 2 - Conductor

BS7655 section 1.2 - Insulation

BS7655 section 2.6 - Sheath

IEC 60332-1 - Flame Retardant

IEC60332-3-22 - Flame retardant

IEC60754-1,2 - Halogen Free

IEC 61034-1,2 - Low Smoke

Code

Letter

Conductor Tinned stranded circular copper, BS6360, class 2 Insulation R EP-rubber, GP4 to BS7655:section 1.2 Inner sheath No inner sheath, additional tapes may be applied Armour/screen No armour

Outer sheath U Flame retardant, halogen-free, enhanced oil resisting thermoset compound (LSF) SW4 to BS7655 section 2.6. (Mud resistant version available on request)

Marking text "metre mark" "year" "DRAKA" "RU" "UKOOA code" "600/1000V" "number of cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable actually supplied)

Outer sheath colour Black

Core identification All cores are offwhite with black numbers No 1,2,3…….

Construction

www.drakaMOG.com Information subject to change without notice

365

Page 373: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

Range and dimensions

Ordering information

Electrical values

Minimum Bending Radius during Installation

Minimum Bending Radius Fixed Installed

Maximum Tensile Load During Installation

Minimum Installation Temperature

8 x D OD < 25 mm - 4 x D, OD > 25 mm - 6 x D 50 N /mm² -20°C

Installation recommendations

Ambient Temp °C 35 40 45 50 55 60 65 70 75 80

Rating factor 1.11 1.05 1.00 0.94 0.88 0.82 0.75 0.67 0.50 0.47

Ambient temperature correction factors

RU 0.6/1KV Unarmoured power cable

Number of cores

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Outer Sheath, mm

Approx Overall Diameter, mm

Weight of Cable Approx.

(Kg/Km)

Copper content Approx. (Kg/Km)

2 1.5 1.6 0.8 1.1 8.5 120 28 2 2.5 2.0 0.8 1.1 9.5 150 46 3 1.5 1.6 0.8 1.1 9 140 42 3 2.5 2.0 0.8 1.1 10 180 69 3 4 2.55 1.0 1.2 12 275 110 3 6 3.15 1.0 1.2 13.5 360 164 4 1.5 1.6 0.8 1.1 10 165 56 4 2.5 2.0 0.8 1.1 11 220 92 3 10 4.05 1.0 1.3 15.5 530 271 3 16 5.15 1.0 1.4 18 770 434

Part number Description Sheath Colour Design standard 840300 RU 0.6/1kV 2X 1.5mm² BLACK BS 6883:1999 840301 RU 0.6/1kV 2X 2.5mm² BLACK BS 6883:1999 840302 RU 0.6/1kV 3X 1.5mm² BLACK BS 6883:1999 840303 RU 0.6/1kV 3X 2.5mm² BLACK BS 6883:1999 840304 RU 0.6/1kV 3X 4mm² BLACK BS 6883:1999 840305 RU 0.6/1kV 3X 6mm² BLACK BS 6883:1999 840306 RU 0.6/1kV 4X 1.5mm² BLACK BS 6883:1999 840307 RU 0.6/1kV 4X 2.5mm² BLACK BS 6883:1999 840312 RU 0.6/1kV 3X 10mm² BLACK BS 6883:1999 840313 RU 0.6/1kV 3X 16mm² BLACK BS 6883:1999

Number of cores

Cross section core, mm²

Max. conductor resistance at

20°C, Ohm/km

Max. conductor resistance at

90°C, Ohm/km

Reactance at 50Hz, Ohm/km

Reactance at 60Hz, Ohm/km

Current rating IEC 60092-352

Table B.4, Ampere

Short circuit rating 1 second, Ampere

2 1.5 12.2 15.6 0.103 0.123 20 210 2 2.5 7.56 9.64 0.096 0.115 26 350 3 1.5 12.2 15.6 0.103 0.123 16 210 3 2.5 7.56 9.64 0.096 0.115 21 350 3 4 4.7 5.90 0.096 0.115 28 560 3 6 3.11 3.97 0.090 0.108 36 840 4 1.5 12.2 15.6 0.103 0.123 16 210 4 2.5 7.56 9.64 0.096 0.115 21 350 3 10 1.84 2.35 0.084 0.101 50 1400 3 16 1.16 1.48 0.080 0.096 67 2240

www.drakaMOG.com Information subject to change without notice

366

Page 374: Prysmian Draka - Marine & Offshore LV HV Cables

Marine, Oil & Gas International

RU 0.6/1KV Earthing cable

Flame retardant halogen-free earthing cable. Enhanced oil-resistance.

RU 0.6/1kV

Operating temperature : 90°C

Operating Voltage : 0.6/1kV

Unarmoured cable for fixed installation for earthing purposes in safe areas. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606.

Application Standards applied BS6883 - Design

BS6360 class 2 - Conductor

BS7655 section 1.2 - Insulation

BS7655 section 2.6 - Sheath

IEC 60332-1 - Flame Retardant

IEC60332-3-22 - Flame retardant

IEC60754-1,2 - Halogen Free

IEC 61034-1,2 - Low Smoke

Code

Letter

Conductor Tinned stranded circular copper, BS6360, class 2 Insulation R EP-rubber, GP4 to BS7655:section 1.2 Inner sheath No inner sheath, additional tapes may be applied Armour/screen No armour

Outer sheath U Flame retardant, halogen-free, enhanced oil resisting thermoset compound (LSF) SW4 to BS7655 section 2.6. (Mud resistant version available on request)

Marking text "metre mark" "year" "DRAKA" "RU" "UKOOA code" "600/1000V" "number of cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable actually supplied)

Outer sheath colour Green/Yellow

Core identification Single core - off white

Construction

www.drakaMOG.com Information subject to change without notice

367

Page 375: Prysmian Draka - Marine & Offshore LV HV Cables

RU 0.6/1KV Earthing cable

Marine, Oil & Gas International

Part number Description Sheath Colour Design standard

840080 RU 0.6/1kV 1X 6mm² YELLOW/GREEN BS 6883:1999

840081 RU 0.6/1kV 1X 16mm² YELLOW/GREEN BS 6883:1999

840082 RU 0.6/1kV 1X 25mm² YELLOW/GREEN BS 6883:1999

840083 RU 0.6/1kV 1X 35mm² YELLOW/GREEN BS 6883:1999

840084 RU 0.6/1kV 1X 70mm² YELLOW/GREEN BS 6883:1999

Number of cores

Cross section core, mm²

Conductor Diameter, mm

Insulation Thickness, mm

Thickness Outer Sheath,

mm Approx Overall Diameter, mm

Approx Weight of Cable (Kg/Km)

Copper content Approx. (Kg/Km)

1 6 3.15 1.0 1 7.5 115 55 1 16 5.15 1.0 1.1 9.5 230 144 1 25 6.45 1.2 1.2 11.5 340 229

1 35 7.65 1.2 1.2 12.5 440 308

1 70 10.85 1.4 1.3 16.5 820 620

Range and dimensions

Ordering information

Number of cores Cross section core, mm²

Max. conductor resistance at 20°C,

Ohm/km

Max. conductor resistance at 90°C,

Ohm/km

Current rating IEC 60092-352 Table

B.4, Ampere

Short circuit rating 1 second, Ampere

1 6 3.11 3.97 52 840

1 16 1.16 1.48 96 2240

1 25 0.734 0.936 127 3500

1 35 0.529 0.675 157 4900

1 70 0.27 0.344 242 9800

Electrical values

Ambient Temp °C 35 40 45 50 55 60 65 70 75 80

Rating factor 1.11 1.05 1.00 0.94 0.88 0.82 0.75 0.67 0.50 0.47

Minimum Bending Radius during Installation

Minimum Bending Radius Fixed Installed

Maximum Tensile Load During Installation

Minimum Installation Temperature

8 x D OD < 25 mm - 4 x D, OD > 25 mm - 6 x D 50 N /mm² -20°C

Installation recommendations

Ambient temperature correction factors

www.drakaMOG.com Information subject to change without notice

368

Page 376: Prysmian Draka - Marine & Offshore LV HV Cables

For maintenance and repair needs, or expert guidance for new-build

projects, please contact any of our worldwide locations: EUROPE: Unit 3 Peterseat Drive Peterseat Park Altens Industrial Estate Aberdeen AB12 3HT U.K. tel: +44 1224 244800 fax: +44 1224 249839

AMERICAS: 1610 Greens Road, Suite 300 Houston, TX 77032 U.S.A. tel: +1 281 209 1070 fax: +1 281 209 3857

ASIA-PACIFIC: 25 Tuas South Street 1 Singapore 638034 tel: +65 6897 7888 fax: +65 6897 7333

www.DrakaMOG.com © 2009 Draka Offshore. All rights reserved.