project tarpon bay blvd. - d.n. higginsdnhiggins.com/docs/rfq 14-6213-105 spec - plans.pdf ·...
TRANSCRIPT
FAITH BIBLE CHURCH
PART OF SECTION 29, 30, TOWNSHIP 48S, RANGE 26E,COLLIER COUNTY, FLORIDA
MARCH, 2017 130063.00.25
MARK J. SUNYAK, P.E. STATE OF FLORIDA LICENSE NO. 62725
RWA, INC. STATE OF FLORIDA BUSINESS CERTIFICATE NO. EB-0007663
DATE: PROJECT No:
ENGINEER'S SEALSTAMPS
REVISIONSNo. DATE APPROVEDREVISION
PROJECT LOCATION PROJECT SITE
PROJECTSITE
PROJECTLOCATION
May 31, 2017 12:02 PM K:\2013\130063.00.25 13-6164 Faith Bible Church Water Main\004 Final Design Phase-100% Plans\Current Plans\Sheet Files\01 1300630025C COVER SHEET.dwg
6610 Willow Park Drive, Suite 200
Naples, Florida 34109 (239) 597-0575
FAX: (239) 597-0578
www.consult-rwa.com
FORCOLLIER COUNTY PUBLIC UTILITIES DEPARTMENT
ELEVATIONS BASED ON NORTH AMERICAN VERTICAL
DATUM NAVD88. CONVERSION FROM NAVD88 TO
NGVD29: NAVD88 +1.23'=NGVD29.
COUNTY SENIOR PROJECT MANAGER:
BENJAMIN N. BULLERT, P.E.
ENGINEERING & PROJECT MANAGEMENT DIVISION
3339 EAST TAMIAMI TRAIL
SUITE 303 BUILDING H
NAPLES, FLORIDA 34104
(239)-252-2583
WATER MAIN EXTENSION
IMMOKALEE RD.
TA
RP
ON
BA
Y B
LV
D.
OA
KE
S B
LV
D.
FAITH
BIBLE
CHURCH
SHEET INDEXSheet
Number Sheet Title1 COVER SHEET
2 GENERAL NOTES
3 OVERALL SITE PLAN
4 PLAN AND PROFILE
5 UTILITY DETAILS
6 EROSION CONTROL PLAN
AUTUMN OAKS LN. (24th AVE. NE)
DEMOLITION NOTES:
1. ALL ITEMS TO BE REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED AT THE
EXPENSE OF THE CONTRACTOR, INCLUDING ALL DUMPING FEES, UNLESS OTHERWISE NOTED. ALL ITEMS SHALL BE
REMOVED TO A DEPTH OF 2' BELOW EXISTING GRADE, OR 2' BELOW THE INVERT OF ANY PROPOSED UTILITIES. EXISTING
UTILITIES, SERVICING BUILDINGS TO BE REMOVED SHALL BE PLUGGED BELOW EXISTING GRADE AND BROUGHT TO THE
ATTENTION OF OWNER'S REPRESENTATIVE AND THE ENGINEER IMMEDIATELY.
2. THIS PLAN IS NOT INTENDED TO BE ALL INCLUSIVE OF EXISTING FACILITIES OR MATERIALS TO BE REMOVED. CONTRACTOR
SHALL BE RESPONSIBLE TO VERIFY THE SCOPE OF WORK IN REGARDS TO MODIFICATIONS OF THE SITE TO ACCOMMODATE
PROPOSED IMPROVEMENTS. THIS PLAN DOES NOT ADDRESS EXISTING UNDERGROUND UTILITIES/FACILITIES WHICH MAY
BE ENCOUNTERED DURING DEMOLITION OR IMPROVEMENTS. CONTRACTOR SHALL PROTECT AND/OR REPLACE THOSE
EXISTING UTILITIES REQUIRED TO ACCOMMODATE THIS PROJECT. OTHER UNDERGROUND UTILITIES TO BE REMOVED OR
ABANDONED SHALL BE DISCARDED, DISENGAGED OR REMOVED IN A MANNER CONSISTENT WITH INDUSTRY SAFETY
STANDARDS, AS REQUIRED BY OWNER'S REPRESENTATIVE.
3. ALL ASPHALT PAVEMENT TO BE REMOVED SHALL BE MECHANICALLY SAW-CUT IN ORDER TO ENSURE CLEAN, STRAIGHT
EDGES. CONTRACTOR SHALL COORDINATE THE LIMITS OF THE ASPHALT REMOVAL WITH THIS DEMOLITION PLAN.
4. CONTRACTOR SHALL COORDINATE THE REMOVAL OF THE EXISTING FACILITIES WITH THE OWNER'S REPRESENTATIVE WITH
REGARDS TO WHEN THE INDIVIDUAL ITEMS ARE TO BE REMOVED.
5. CONTRACTOR SHALL PROVIDE A SAFE, OPERABLE SITE FOR EMPLOYEES AND PUBLIC FOR THE CONSTRUCTION AND
FUNCTIONS THAT WILL CONTINUE TO OCCUR DURING THE CONSTRUCTION ACTIVITIES.
WATER, IRRIGATION AND SEWER NOTES:
1. ALL ONSITE WATER AND SEWER FACILITIES SHALL BE OWNED AND MAINTAINED BY COLLIER COUNTY.
2. ALL WATER AND SEWER CONSTRUCTION SHALL CONFORM TO COLLIER COUNTY STANDARDS AND SPECIFICATIONS.
3. ALL EXISTING UNDERGROUND UTILITIES ARE BASED ON AVAILABLE RECORD INFORMATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO
LOCATE APPROPRIATE EXISTING UTILITIES AND REPORT DISCREPANCIES TO ENGINEER IMMEDIATELY.
4. INSTALLATION OF SUBSURFACE CONSTRUCTION, TO INCLUDE, WATER AND IRRIGATION LINES, SEWER LINES, PUBLIC UTILITIES AND
STORM DRAINAGE IS REQUIRED PRIOR TO COMPACTION OF SUBGRADE AND ROADWAY CONSTRUCTION.
5. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ALL UTILITY LINES AND SERVICES DAMAGED DURING CONSTRUCTION, INCLUDING
IRRIGATION LINES AND SERVICES. THE APPROPRIATE UTILITY SHALL BE NOTIFIED OF ALL DAMAGED LINES PRIOR TO REPAIR. ALL
NECESSARY REPAIRS SHALL BE PERFORMED IMMEDIATELY UPON DAMAGE OF LINE, AT THE CONTRACTOR'S EXPENSE.
6. THE CONTRACTOR SHALL PROVIDE 48 HOURS WRITTEN NOTICE TO THE ENGINEER AND UTILITY COMPANY PRIOR TO THE FOLLOWING TO
ALLOW FOR INSPECTIONS REQUIRED BY ORDINANCE 2004-31 SECTION 9.4.2.2
6.A. COMMENCEMENT
6.B. CHANGES TO APPROVED SCHEDULES, SUBCONTRACTORS, OR RESIDENT SUPERINTENDENT.
6.C. POTABLE, IRRIGATION, WASTEWATER AND GENERAL SYSTEMS
6.C.A. HOT TAPS TO POTABLE WATER LINES LARGER THAN 6" AND WASTEWATER SYSTEMS GREATER THAN 4". *
6.C.B. MASTER METER AND BYPASS PIPING.
6.C.C. JACK & BORE CASINGS. *
6.C.D. PRESSURE TESTS. *
6.C.E. INFILTRATION/EXFILTRATION TESTS. *
6.C.F. LIFT STATION INSTALLATION, PRIOR TO COVER-UP AND START-UP. *
6.C.G. LIFT STATION START-UP. *
6.C.H. LAMPING OF SEWER LINES. *
6.C.I. PIGGING AND FLUSHING OF WASTEWATER LINES, FORCE MAINS, POTABLE WATER MAINS, AND NON-POTABLE IRRIGATION
LINES. * NOTE: FULL BORE FLUSHING AND PIGGING OF POTABLE WATER LINES NEED ONLY WATER DEPARTMENT
INSPECTION.
6.C.J. TELEVISION VIDEO TAPING OF WASTEWATER LINES AT END OF CONSTRUCTION AND THE WARANTY PERIOD ("IN-OFFICE
REVIEW").
6.C.K. CONFLICT CONSTRUCTION. *
6.C.L. CONNECTIONS TO EXISTING POTABLE WATER, NON-POTABLE IRRIGATION WATER AND WASTE WATER SYSTEMS. *
6.C.M. 8" DIAMETER OR LARGER CASING INSTALLATIONS. *
6.C.N. OTHER SPECIAL REQUIREMENTS AS SPECIFIED BY THE COUNTY STAFF AT THE TIME OF CONSTRUCTION DOCUMENT
APPROVAL.
6.C.O. CLORINATION OF WATER LINES AND REFLUSHING OF LINE AFTER CHLORINATION (NEEDS WATER DEPARTMENT
INSPECTION ONLY). *
6.C.P. INSTALLATION OF TEMPORARY METERS/BACKFLOWS. *
6.C.Q. BACTERIOLOGICAL SAMPLING (NEEDS WATER INSPECTION ONLY). *
6.C.R. HOT TAPS TO ANY WATER CONCRETE MAINS, PRESSURE TESTS ON LINES 20" OR GREATER, AND CONNECTIONS TO
EXISTING POTABLE SYSTEMS GREATER THAN 12" NEED TO BE INSPECTED BY THE WATER DEPARTMENT AND THE COLLIER
COUNTY. *
6.C.S. FIRE FLOW TESTING.
6.C.T. A COLLIER COUNTY INSPECTOR OR OTHER QUALIFIED EMPLOYEE MUST BE PRESENT AT THE INSPECTIONS NOTED WITH "*"
ABOVE.
7. FITTINGS SHALL BE USED TO MAINTAIN PLAN ALIGNMENT OF POTABLE WATER MAINS. DEVIATION FROM PLAN ALIGNMENT SHALL NOT
BE MORE THAN 12" FROM PLAN CENTERLINE OF MAIN. CONTRACTOR SHALL PREPARE RECORD DRAWING OF ALL FITTINGS NOT SHOWN
ON THIS PLAN.
8. MINIMUM COVER FOR ALL WATER MAINS SHALL BE MEASURED FROM FINISHED GRADES, MINIMUM DEPTH OF 30" MAXIMUM DEPTH OF
48". IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE MINIMUM COVER, REGARDLESS OF EXISTING GRADE. PERIODIC CHECKS
FOR MINIMUM COVER WILL BE MADE BY THE COLLIER COUNTY AND ENGINEER.
9. CONTRACTOR SHALL CONSTRUCT ALL WATER APPURTENANCES INCLUDING METER BOXES, BLOW-OFFS, VALVE BOXES, AIR RELEASE
VALVES, FIRE HYDRANTS, ETC. TO FINISHED GRADE. CONTRACTOR SHALL COORDINATE DURING THE CONSTRUCTION STAKEOUT AND
PRIOR TO CONSTRUCTION OF SAID APPURTENANCES WITH OWNER AND ENGINEER REGARDING FINISHED GRADE. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO ENSURE CONSTRUCTION OF SAID APPURTENANCES TO FINISHED GRADE.
10. ALL POTABLE WATER MAINS SHALL BE SEPARATED FROM SANITARY SEWER BY A MINIMUM HORIZONTAL DISTANCE OF TEN FEET
MEASURED EDGE TO EDGE AND A VERTICAL DISTANCE OF 18" MEASURED BETWEEN THE INVERT OF THE UPPER PIPE AND THE CROWN OF
THE LOWER PIPE. WHERE MINIMUM SEPARATION CANNOT BE MAINTAINED, SEE CROSSOVER DETAIL REQUIREMENTS.
11. POTABLE WATER MAINS UNDER PAVEMENT SHALL BE POLYVINYL CHLORIDE PIPE (PVC) AWWA C-900, CLASS 200, DR 14, OR CLASS 51
DUCTILE IRON PIPE. ALL OTHER POTABLE WATER MAINS SHALL BE AWWA C-900, CLASS 150, DR 14 PVC, COLOR CODED "BLUE".
12. REFER TO PLAT AND/OR BOUNDARY SURVEY FOR EASEMENTS OF RECORD.
13. MINIMUM 18" SEPARATION SHALL BE PROVIDED BETWEEN WATER, SEWER, AND CONDUITS FOR ANY OTHER UTILITY.
14. ALL UTILITY CONSTRUCTION TO BE IN ACCORDANCE WITH COLLIER COUNTY PUBLIC UTILITIES DIVISION SPECIFICATIONS, LATEST
EDITION.
15. CONTRACTOR SHALL BE RESPONSIBLE FOR BOIL WATER NOTICES AND BACTERIOLOGICAL SAMPLING FOR ANY EXISTING WATER MAINS
THAT ARE POTENTIALLY CONTAMINATED DURING CONSTRUCTION.
16. FIRE HYDRANTS SHALL BE MARKED IN A UNIFORM MANNER APPROVED BY THE LOCAL FIRE DISTRICT.
17. ALL WATER METERS SHALL BE SIZED BY COLLIER COUNTY PUBLIC UTILITIES.
18. MASTER WATER METER TO BE INSTALLED BY CONTRACTOR. WATER METERS SMALLER THAN 2" TO BE INSTALLED BY COLLIER COUNTY.
19. CONTRACTOR WILL INSTALL WATER SERVICE LINES & METER BOX.
20. ALL FIRE HYDRANTS REFERENCED IN THIS PLAN SET INCLUDE HYDRANT AND HYDRANT VALVE.
21. FIRE HYDRANTS AND WATER SERVICES MAY BE USED FOR TEMPORARY SAMPLE POINTS (TSP) AS SHOWN ON THE PLANS.
GENERAL NOTES:
1. ALL ONSITE INFRASTRUCTURE SHALL BE OWNED AND MAINTAINED BY COLLIER COUNTY.
2. ALL CONSTRUCTION SHOWN ON THESE DRAWINGS SHALL CONFORM TO THE COLLIER COUNTY STANDARDS AND
SPECIFICATIONS AND THE CONTRACT TECHNICAL SPECIFICATIONS.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS PRIOR TO COMMENCEMENT OF CONSTRUCTION. ANY
DEVIATION IN PLAN INFORMATION SHALL BE REPORTED TO ENGINEER IMMEDIATELY.
4. CONTRACTOR IS REQUIRED TO OBTAIN FROM THE ENGINEER AND OWNER WRITTEN APPROVAL FOR ANY DEVIATIONS
FROM THE PLANS AND/OR SPECIFICATIONS.
6. THE APPROVAL OF THESE CONSTRUCTION PLANS DOES NOT AUTHORIZE CONSTRUCTION OF REQUIRED IMPROVEMENTS
WHICH ARE INCONSISTENT WITH EASEMENTS OF RECORD.
8. ALL ELEVATIONS REFERENCED WITHIN THIS PLAN SET ARE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88),
UNLESS OTHERWISE STATED. CONVERSION TO THE NATIONAL GEODETIC VERTICAL DATUM OF 1929 (NGVD 29) IS +1.23'.
9. REFER TO PLAT AND/OR BOUNDARY SURVEY FOR EASEMENTS OF RECORD.
14. ALL PROHIBITED EXOTIC VEGETATION SHALL BE REMOVED FROM THE SITE AND IT SHALL BE MAINTAINED FREE OF
EXOTICS IN PERPETUITY.
15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UTILITIES, WHETHER PRIVATE OR PUBLIC, PRIOR TO
EXCAVATION. THE INFORMATION AND DATA SHOWN WITH RESPECT TO EXISTING UNDERGROUND FACILITIES AT OR
CONTIGUOUS TO THE SITE IS APPROXIMATE AND BASED ON INFORMATION FURNISHED BY THE OWNERS OF SUCH
UNDERGROUND FACILITIES OR ON PHYSICAL APPURTENANCES OBSERVED IN THE FIELD, AND BEST AVAILABLE RECORD
DRAWING INFORMATION. THE OWNER AND ENGINEER SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR
COMPLETENESS OF ANY SUCH INFORMATION OR DATA; AND, THE CONTRACTOR SHALL HAVE FULL RESPONSIBILITY FOR
REVIEWING AND CHECKING ALL SUCH INFORMATION AND DATA, FOR LOCATING ALL UNDERGROUND FACILITIES BEFORE
AND DURING CONSTRUCTION, FOR THE SAFETY AND PROTECTION THEREOF, AND REPAIRING ANY DAMAGE THERETO
RESULTING FROM THE WORK. THE COST OF ALL WILL BE CONSIDERED AS HAVING BEEN INCLUDED IN THE CONTRACT
PRICE. THE CONTRACTOR SHALL NOTIFY ANY AFFECTED UTILITY COMPANIES OR AGENCIES IN WRITING AT LEAST 48
HOURS PRIOR TO BEGINNING CONSTRUCTION.
16. CONTRACTOR SHALL REMOVE ALL MUCK AND OTHER UNSUITABLE MATERIAL FROM FILL AREAS PRIOR TO PLACEMENT
OF FILL. ALL MUCK AND UNSUITABLE MATERIAL SHALL BE STOCKPILED AS DETERMINED BY OWNER.
LIST OF STANDARD ABBREVIATIONSTERM ABBREVIATION TERM ABBREVIATION
ACCESS EASEMENT
AFD
INVERT INV
AIR RELEASE VALVE ARV LAKE MAINTENANCE EASEMENT LME
AMERICAN WITH DISABILITIES ACT ADA LANDSCAPE BUFFER EASEMENT LBE
BACK OF CURB BOC
LEE COUNTY ELECTRIC COOPERATIVE LCEC
BACKFLOW PREVENTOR BFP
LEFT LT
BASE LINE BL
LINEAL FEET LF
BLOW-OFF BO
MANHOLE MH
CABLE TV CATV
MECHANICAL JOINT MJ
CENTER LINE CL
NATIONAL GEODETIC VERITICAL DATUM NGVD
CLEAN OUT CO
NORTH AMERICAN VERTICAL DATUM NAVD
CONTROL STRUCTURE CS
OUTSIDE DIAMETER OD
CORRUGATED ALUMINUM PIPE CAP
POINT OF CURVATURE PC
CORRUGATED METAL PIPE CMP
POINT OF TANGENCY PT
COLLIER COUNTY UTILITY EASEMENT CUE
POINT OF VERTICAL INTERSECTION PVI
DEPARTMENT OF TRANSPORTATION DOT
POLYVINYL CHLORIDE PVC
DIAMETER DIA
POST INDICATOR VALVE PIV
DIMENSION RATIO DR
PROPERTY LINE PL
DRAINAGE EASEMENT DE
PUBLIC UTILITY EASEMENT PUE
DUCTILE IRON PIPE D.I.P.
PUMP STATION PS
EDGE OF PAVEMENT EOP
RADIUS(X')R
ELEVATION ELEV
REFLECTIVE PAVEMENT MARKER RPM
ELLIPTICAL REINFORCED CONCRETE PIPE ERCP
REINFORCED CONCRETE PIPE RCP
FIBER REINFORCED CONCRETE PIPE FRCP RIGHT RT
FIRE DEPARTMENT CONNECTION FDC
RIGHT OF WAY ROW
FIRE HYDRANT ASSEMBLY FH
SANITARY SEWER SS
FLORIDA DEPARTMENT OF TRANSPORTATION FDOT
STATION STA
FLORIDA POWER & LIGHT FPL
STORM STRUCTURE STR
FLOW LINE FL
TEMPORARY TEMP.
HIGH DENSITY POLYETHYLENE HDPE
TYPICAL TYP.INSIDE DIAMETER ID
AUTOMATIC FLUSHING DEVICE
AE
C.E.CONTROL ELEVATION
TEMPORARY BLOW-OFF ASSEMBLY TBO
TEMPORARY SAMPLE POINT TSP
PERMANENT SAMPLE POINT PSP
FIRE CONTROL DISTRICT FCD
TEMPORARY BACKFLOW TBF
GATE VALVE GV
PLUG VALVE PV
RECLAIMED WATER MAIN RCWM
CONCRETE CONC
HORIZ. SCALE (FULL):
DATECHECKEDDRAWN
RGE:TWP:SEC:
DATE:
TITLE:
CLIENT: PROJECT:
OF
PROJECT NO.: SHEET NUMBER:
REVISIONREV #
HORIZ. SCALE (HALF):
6610 Willow Park Drive, Suite 200
Naples, Florida 34109
(239) 597-0575 FAX: (239) 597-0578
www.consult-rwa.com
Florida Certificates of Authorization
EB 7663 LB 6952
DESIGNED:
DRAWN:
VERT. SCALE (FULL):
VERT. SCALE (HALF):
FILE NAME:
FLORIDA LICENSE NO.
April 13, 2017 1:47 PM K:\2013\130063.00.25 13-6164 Faith Bible Church Water Main\004 Final Design Phase-100% Plans\Current Plans\Sheet Files\02 1300630025C GN.dwg
FAITH BIBLE CHURCH
WATER MAIN EXTENSION
COLLIER COUNTY
PUBLIC UTILITIES DEPARTMENT
2 6130063.00.25
MARCH, 2017
N/A
N/A
29, 30 48S 26E
MJS
MDA
N/A
N/A
02 1300630025C GN
62725
MARK J. SUNYAK, P.E.
GENERAL NOTES
D-X
D-X
D-X
IMMOKALEE RD.
AUTUMN OAKS LN. (24th AVE. NE)
TA
RP
ON
BA
Y B
LV
D.
FAITH BIBLE CHURCH6464 IMMOKALEE RD.
OA
KE
S B
LV
D.
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
W
-X
W-X
W-X
W-X
W-X
W
-
X
W-X
W
-
X
W-X
W
-X
W-X
W-X
W-X
W-X
OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW
WW W
W WW W
W WW W
W W WW
0+
00
1+00
2+00
3+00
4+00
5+00
6+00 6+16
W WW
W WW W
W-X
W-X
W-X
W-X
WW
WW
WW
WW
WW
G-X
G-X
G-X
G-X
G-X
G-X
G-XG-XG-XG-XG-XG-XG-XG-XG-XG-XG-XG-XG-XG-XG-XG-X
G
-
X
G
-X
G-X
G-X
G-X
G-X
G-X
G-X
G-X
W-X W-X W-X W-X W-X W-X W-X W-X W-X
W-X
W-X
W-X
STREET SIGN
(TYP)
EX ENTRY SIGN
EX ROADWAY ESMT
(ROW, DE, IE
, PUE & CUE)
WIDTH VARIES
EX NATURAL GAS LINE
CONTRACTOR TO VERIFY LOCATION
EX OVERHEAD POWER LINE
EX 60' DE
EX 8" PVC FM
EX 18" RCP
EX 24" RCP
EX 30'
ROW ESMT
EX
LA
ND
SC
AP
E E
SM
T
WID
TH
VA
RIE
S
EX 12" PVC WM
FH ASSEMBLY
AUTOMATIC FLUSHING DEVICE
W/ METER
EX DRAINAGE INLET
(TYP)
EX 24" CMP
EX
D
RA
IN
AG
E C
AN
AL
EX UNDERGROUND FPL CONDUIT
CONTRACTOR TO VERIFY LOCATION
2435 TARPON BAY BLVD.
2415 TARPON BAY BLVD.
FAITH BIBLE CHURCH6464 IMMOKALEE RD.
6421 AUTUMN OAKS LN. 6461 AUTUMN OAKS LN. 2391 OAKS BLVD.
EX TOP OF BANK
(TYP)
EX EOP
(TYP)
EX BOC
(TYP)
DIRECTIONAL DRILL
8" HDPE DR 13.5 RWM W/
14" HDPE DR 13.5 CASING
CONNECT TO EX 12" PVC WM W/
12"x8" TAPPING SLEEVE & VALVE
8" PVC DR 14 WM
8" PVC DR 14 WM
EX GATE
EX PROPERTY LINE
(TYP)
EX 15' P
UE
EX
10' P
UE
EX DRAINAGE INLET
(TYP)
EX 6' CONC SIDEWALK
30' ROW ESMT
30' ROW ESMT
EX BOAT RAMP
EX 1 1/2" WATER SERVICE
TO BE ABANDONED, CAP ENDS
CAP EX WATER SERVICE
CONNECT TO EX 1 1/2" WATER SERVICE
1 1/2" POLYTUBE WATER SERVICE,
BORE AS NEEDED
CONNECT 1 1/2" WATER SERVICE
INSTALL 1 1/2" WATER METER
& BACKFLOW PREVENTER
EX UNDERGROUND FPL CONDUIT
CONTRACTOR TO VERIFY LOCATION
40' C
UE &
A
E
EX NATURAL GAS LINE
CONTRACTOR TO VERIFY LOCATION
EX 20" WM
REMOVE METER & BFP
CAP EX SERVICE (BOTH DIRECTIONS)
SHUT & PLUG CORP.
& CAP CONN.
HORIZ. SCALE (FULL):
DATECHECKEDDRAWN
RGE:TWP:SEC:
DATE:
TITLE:
CLIENT: PROJECT:
OF
PROJECT NO.: SHEET NUMBER:
REVISIONREV #
HORIZ. SCALE (HALF):
6610 Willow Park Drive, Suite 200
Naples, Florida 34109
(239) 597-0575 FAX: (239) 597-0578
www.consult-rwa.com
Florida Certificates of Authorization
EB 7663 LB 6952
DESIGNED:
DRAWN:
VERT. SCALE (FULL):
VERT. SCALE (HALF):
FILE NAME:
FLORIDA LICENSE NO.
May 24, 2017 8:25 AM K:\2013\130063.00.25 13-6164 Faith Bible Church Water Main\004 Final Design Phase-100% Plans\Current Plans\Sheet Files\03 1300630025C MP01.dwg
FAITH BIBLE CHURCH
COLLIER COUNTY
PUBLIC UTILITIES DEPARTMENT
3 6130063.00.25
MARCH, 2017
1" = 40'
1" = 80'
29, 30 48S 26E
MJS
MDA
N/A
N/A
03 1300630025C MP01
62725
MARK J. SUNYAK, P.E.
OVERALL SITE PLAN
Feet
0 40 80
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
F-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
D-X
W-X
W-X
W-X
W
-
X
W
-
X
W-X
W-X
W-X
W-X
W
-
X
W
-
X
W-X
W-X
OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW
W WW W
W WW W
W WW W
W WW W W
W WW W
W WW W
W WW W
W
W WW W
W WW
W WW W
W WW
W
WW
WW
WW
WW
G-X
G-X
G-X
G-X
G-X
G-X
G-X
G-X
G-X
G-X
G-X
G-X
EX NATURAL GAS LINE
CONTRACTOR TO VERIFY LOCATION
EX 8" PVC FM
EX 24" RCP
ROADWAY ESMT
(ROW, DE, PUE & CUE)
WIDTH VARIES
ROW
WIDTH VARIES
EX CONC SIDEWALK
EX 12" PVC WM
CONTRACTOR TO VERIFY
LOCATION & ELEV
EX FPL CONDUIT
CONTRACTOR TO VERIFY
LOCATION & ELEV
EX
D
RA
IN
AG
E C
AN
AL
EX BOAT RAMP
POWER POLEOVER HEAD POWER LINES
EX ELEC PYLON
EX STREET SIGN
(TYP)
EX GATE
EX DRAINAGE INLET
INV = 8.6'
EX 24" CMP
EX ASPHALT DRIVEWAY
AUTUMN OAKS LN. (24th AVE. NE)EX CENTURY LINK CONDUIT
EX ENTRY SIGN
EX ELEC PYLON
TA
RP
ON
BA
Y B
LV
D.
20' LBE
60' DE
GUY WIRE ANCHORS
EX IRRIGATION VALVE
(TYP)
EX STREET SIGN
EX COMM VAULT
EX LIGHT POLE
EX STREET SIGN
(TYP)
EX STREET SIGN
EX EOP
(TYP)
EX EOP
(TYP)
EX FH ASSEMBLY
AUTOMATIC FLUSHING DEVICE
W/ 2" WATER METER
0+
00
1+00
2+00
3+00
4+00
5+00
6+00 6+16
12"x8" TAPPING
SLEEVE & VALVE
(SUBAQUEOUS
ISOLATION VALVE)
(2) 8" - 45° BEND
HDPE TRANSITION
COUPLING
HDPE TRANSITION COUPLING
EX TOP OF BANK
(TYP)
EX TOP OF BANK
(TYP)
FH ASSEMBLY
W/ 6" GV
L
A
N
D
S
C
A
P
E
A
R
E
A
30' R
OW
ESM
T
30' R
OW
ESM
T
EX DRAINAGE INLET
INV = 8.7'
REPAIR ASPHALT DRIVEWAY
MATCH EXISTING
EX EOP
(TYP)
EX EOP
(TYP)
EX FPL CONDUIT
CONTRACTOR TO VERIFY
LOCATION & ELEV
EX BOC
(TYP)
EX BOC
(TYP)
ELECTRIC
TRANSFORMER
30' ROW ESMT
CONNECT 1 1/2" WATER SERVICE
INSTALL 1 1/2" WATER METER
& BACKFLOW PREVENTER
1 1/2" POLYTUBE WATER SERVICE
SEE SHEET 3 FOR CONNECTION LIMITS
ARV
8" GV
CU
E &
A
E
WID
TH
V
AR
IES
(2) EX FPL CONDUIT
CONTRACTOR TO VERIFY
LOCATION & ELEV
EX 12" PVC WM
CONTRACTOR TO VERIFY
LOCATION & ELEV
8" PVC DR 14 WM
ARV
EX FPL CONDUIT
CONTRACTOR TO VERIFY
LOCATION & ELEV
ROADWAY ESMT
(ROW, DE, PUE & CUE)
WIDTH VARIES
189'± HORIZONTAL DIRECTIONAL DRILL
192'± 8" HDPE DR 11 WM
SUBAQUEOUS
WATER SETUP
-2
0
2
4
6
8
10
12
14
-2
0
2
4
6
8
10
12
14
0+00 1+00 2+00 3+00 4+00 5+00 6+006+10
EX 12" PVC WM
CONTRACTOR TO VERIFY
LOCATION & ELEV
EX 24" RCP
CONTRACTOR TO VERIFY
LOCATION & ELEV
EX 8" PVC FM
CONTRACTOR TO VERIFY
LOCATION & ELEV
389 LF 8" PVC DR 14 WM
12"x8" TAPPING
SLEEVE & VALVE
(SUBAQUEOUS
ISOLATION VALVE)
HDPE TRANSITION
COUPLING
8" HDPE DR 11 WM
(2) 8" - 45° BEND
AUTOMATIC FLUSHING DEVICE
W/ 2" WATER METER
EX GROUND ABOVE WM
36" MIN
189'± HORIZONTAL DIRECTIONAL DRILL
192'± 8" HDPE DR 11 WM
24" MIN
8" BENDS AS NEEDED
HDPE TRANSITION
COUPLING
8" BENDS AS NEEDED
30" MIN
48" MAX
ARV
8" GV
EX 12" PVC WM
CONTRACTOR TO VERIFY
LOCATION & ELEV
EX FPL CONDUIT
CONTRACTOR TO VERIFY
LOCATION & ELEV
18" MIN
8"x6" FH TEE
60' DE
SFWMD CANAL DESIGN
2:1
28'
1:1
12'
12.8' NAVD88
ARV
APPROX WATER LEVEL
EX NATURAL GAS LINE
CONTRACTOR TO VERIFY
LOCATION & ELEV
21 LF 8" PVC
DR 14 WM
HORIZ. SCALE (FULL):
DATECHECKEDDRAWN
RGE:TWP:SEC:
DATE:
TITLE:
CLIENT: PROJECT:
OF
PROJECT NO.: SHEET NUMBER:
REVISIONREV #
HORIZ. SCALE (HALF):
6610 Willow Park Drive, Suite 200
Naples, Florida 34109
(239) 597-0575 FAX: (239) 597-0578
www.consult-rwa.com
Florida Certificates of Authorization
EB 7663 LB 6952
DESIGNED:
DRAWN:
VERT. SCALE (FULL):
VERT. SCALE (HALF):
FILE NAME:
FLORIDA LICENSE NO.
June 15, 2017 10:44 AM K:\2013\130063.00.25 13-6164 Faith Bible Church Water Main\004 Final Design Phase-100% Plans\Current Plans\Sheet Files\04 1300630025C PP01.dwg
FAITH BIBLE CHURCH
COLLIER COUNTY
PUBLIC UTILITIES DEPARTMENT
4 6130063.00.25
MARCH, 2017
1" = 20'
1" = 40'
29, 30 48S 26E
MJS
MDA
N/A
N/A
04 1300630025C PP01
62725
MARK J. SUNYAK, P.E.
PLAN AND PROFILE
Feet
0 20 40
HORIZ. SCALE (FULL):
DATECHECKEDDRAWN
RGE:TWP:SEC:
DATE:
TITLE:
CLIENT: PROJECT:
OF
PROJECT NO.: SHEET NUMBER:
REVISIONREV #
HORIZ. SCALE (HALF):
6610 Willow Park Drive, Suite 200
Naples, Florida 34109
(239) 597-0575 FAX: (239) 597-0578
www.consult-rwa.com
Florida Certificates of Authorization
EB 7663 LB 6952
DESIGNED:
DRAWN:
VERT. SCALE (FULL):
VERT. SCALE (HALF):
FILE NAME:
FLORIDA LICENSE NO.
March 27, 2017 10:07 AM K:\2013\130063.00.25 13-6164 Faith Bible Church Water Main\004 Final Design Phase-100% Plans\Current Plans\Sheet Files\1300630025C UTILITY DETAILS.dwg
FAITH BIBLE CHURCH
COLLIER COUNTY
PUBLIC UTILITIES DEPARTMENT
5 6130063.00.25
MARCH, 2017
1" = 50'
1" = 100'
29 48S 26E
MJS
MDA
N/A
N/A
1300630025C UTILITY DETAILS
62725
MARK J. SUNYAK, P.E.
UTILITY DETAILS
HORIZ. SCALE (FULL):
DATECHECKEDDRAWN
RGE:TWP:SEC:
DATE:
TITLE:
CLIENT: PROJECT:
OF
PROJECT NO.: SHEET NUMBER:
REVISIONREV #
HORIZ. SCALE (HALF):
6610 Willow Park Drive, Suite 200
Naples, Florida 34109
(239) 597-0575 FAX: (239) 597-0578
www.consult-rwa.com
Florida Certificates of Authorization
EB 7663 LB 6952
DESIGNED:
DRAWN:
VERT. SCALE (FULL):
VERT. SCALE (HALF):
FILE NAME:
FLORIDA LICENSE NO.
May 31, 2017 12:02 PM K:\2013\130063.00.25 13-6164 Faith Bible Church Water Main\004 Final Design Phase-100% Plans\Current Plans\Sheet Files\06 1300630025C EC.dwg
FAITH BIBLE CHURCH
COLLIER COUNTY
PUBLIC UTILITIES DEPARTMENT
6 6130063.00.25
MARCH, 2017
1" = 60'
1" = 120'
29, 30 48S 26E
MJS
MDA
N/A
N/A
06 1300630025C EC
62725
MARK J. SUNYAK, P.E.
EROSION CONTROL PLAN
SILT FENCE LOCATIONSCALE: 1" = 60'
GRATE INLET
STAKED SYNTHETIC SOCK
WOODEN STAKE
FILTERED WATER
4" M
IN
.
12" M
IN
.
GRATE INLET
MIN
.
4"
4"
12"
3'
SURFACE RUN-OFF
3' MINIMUM
SURFACE RUN-OFF
4"
F
L
O
W
6'
4"
4. BACKFILL AND COMPACT THE EXCAVATED SOIL.
2. EXCAVATE A 4" x 4" TRENCH UPSLOPE ALONG THE LINE OF STAKES.
N.T.S.
PLATE 1.06a
GENERAL NOTES:
12" M
IN
.
SPECIFIC APPLICATION
WOODEN STAKE
4"
F
L
O
W
6'
F
L
O
W
3. STAPLE FILTER MATERIAL TO STAKES AND EXTEND IT INTO THE TRENCH.
1. SET THE STAKES
FLO
W
N.T.S.
F
L
O
W
4"
S
O
C
K
W
I
D
T
H
F
L
O
W
1. EXCAVATE THE TRENCH 2. PLACE AND STAKE SYNTHETIC SOCKS
4. BACKFILL AND COMPACT THE EXCAVATED SOIL.
CONSTRUCTION OF A SYNTHETIC SOCK BARRIER
4"
CONSTRUCTION OF A FILTER BARRIER
1. A SYNTHETIC FILTER SOCK SHALL BE A PHOTODEGRADABLE OF BIODEGRADABLE MESH
NETTING MATERIAL PROVIDING A MINIMUM OF 9 MONTHS EXPECTED USABLE LIFE AT A
TEMPERATURE RANGE OF 0°F TO 120°F.
2. THE MEDIA WITHIN THE FILTER SOCK SHALL CONTAIN COMPOSTED MATERIAL SUITABLE
FOR REMOVING SOLIDS AND SOLUBLE POLLUTANTS FROM STORMWATER RUNOFF.
3. SOCKS ARE AVAILABLE IN 9-INCH, 12-INCH, 18-INCH, AND 24-INCH DIAMETERS FOR A
VARIETY OF APPLICATIONS AND MAY BE STACKED FOR INCREASED STORAGE CAPACITY.
4. POSTS FOR THE FILTER SOCK SHALL BE 2 X 2 INCHES WOOD (PREFERRED), OR EQUIVALENT
METAL WITH A MAXIMUM HEIGHT OF 3 FEET.
5. POSTS SHALL BE SPACED A MAXIMUM OF 10 FEET APART AT THE BARRIER LOCATION AND
DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 8 INCHES IN CLAY SOILS OR 12
INCHES FOR SAND SOILS. FOR USE ON PAVEMENT, HEAVY CONCRETE BLOCKS SHALL BE
USED BEHIND THE FILTER SOCKS FOR STABILIZATION.
6. A MINIMUM OF 1 FOOT OVERLAP IS REQUIRED WHEN JOINING TWO FILTER SOCKS
TOGETHER. TWO STAKES MUST BE DRIVEN THROUGH BOTH ADJOINING ENDS.
7. FILTER SOCKS SHALL BE REMOVED OR CUT OPEN WHEN THEY HAVE SERVED THEIR USEFUL
PURPOSE, BUT NOT BEFORE THE UPSLOPE AREA IS PERMANENTLY STABILIZED.
CONSTRUCTION NOTES:
SOURCE: FLORIDA STORMWATER EROSION AND
SEDIMENTATION CONTROL INSPECTOR'S MANUAL
BY FDEP
FABRIC FILTER
BARRIER
EXISTING
GROUND
SOURCE: INSTALLATION OF STRAW AND
FABRIC FILTER BARRIERS FOR SEDIMENT
CONTROL, SHERWOOD and WYANT
PRIOR TO COMMENCEMENT OF CONSTRUCTION ACTIVITY
APPROPRIATE EROSION CONTROL DEVICES SHALL BE INSTALLED TO
CONTROL AND REDUCE SOIL EROSION AND SEDIMENT TRANSPORT TO
OFF-SITE AREAS. THE CONTRACTOR SHALL MAINTAIN THESE DEVICES
THROUGHOUT THE DURATION OF CONSTRUCTION. ALL DEVICES SHALL
REMAIN IN PLACE UNTIL THE SURROUNDING AREAS ARE ESTABLISHED.
THE FOLLOWING MINIMUM REQUIREMENTS ARE RECOMMENDED:
(REFERENCE FLORIDA DEVELOPMENT MANUAL, FDER, PPS 6-301 TO 6-500).
THESE BEST MANAGEMENT PRACTICES (BMP) ARE TYPICAL OF
REQUIREMENTS FOR SOIL EROSION CONTROL PER LOCAL REQUIREMENTS.
THEY MAY NOT CONSTITUTE COMPLETE REQUIREMENTS FOR
COMPLIANCE WITH REGULATORY AGENCIES AND SPECIFIC PERMIT
CONDITIONS.
A) BMP 1.01 TEMPORARY GRAVEL CONSTRUCTION ENTRANCE
B) BMP 1.05 SYNTHETIC SOCK BARRIER
C) BMP 1.06 SILT FENCE
D) BMP 1.08 STORM INLET DRAIN PROTECTION
THIS METHOD OF INLET PROTECTION IS APPLICABLE WHERE THE INLET DRAINS A RELATIVELY FLAT
AREA (SLOPES NO GREATER THAN 5 PERCENT) WHERE SHEET OR OVERLAND FLOWS (NOT EXCEEDING
0.5 CFS) ARE TYPICAL. THE METHOD SHALL NOT APPLY TO INLETS RECEIVING CONCENTRATED
FLOWS, SUCH AS IN STREET OR HIGHWAY MEDIANS.
10' MAXIMUM SPACING WITH WIRE
SUPPORT FENCE ALONG BOUNDARY. 6'
MAXIMUM SPACING WITHOUT WIRE
SUPPORT FENCE ALONG BOUNDARY.
WOODEN
STAKE
FABRIC FILTER
BARRIER
WIRE REINFORCED
STAKED & TRENCHED
SILT FENCE (TYPICAL)
EXISTING
GROUND
RUN-OFF WATER
WITH SEDIMENT
COMPACTED SOIL
TO PREVENT PIPING
SYNTHETIC SOCKS STAKED WITH STAKES
PLACED A MAXIMUM 10' APART
SYNTHETIC SOCK DROPINLET SEDIMENT FILTER
STAKE & FILTER FABRICBURIAL DETAIL
DOUBLE ROWSTAKED SILT FENCE
2.
3.
N.T.S.
TEMPORARY GRAVEL CONSTRUCTION ENTRANCE
BMP 1.01 TEMPORARY GRAVEL CONSTRUCTION ENTRANCE
PLATE 1.06b
N.T.S.
ELEVATION
1.
6
'
4"
24"
N.T.S.
S
L
O
P
E
4'
4'
BMP 1.06 SILT FENCE
N.T.S.
SEDIMENT FENCE DETAIL
SEDIMENTATION / EROSION CONTROL DETAIL
GRATE INLET
4"
PLAN
SOCK TIES
12"
N.T.S.
1.
NOTE:
2.
(TYPICAL FOR ALL GRATE INLETS)
ANCHORING SOCKSPROFILE
SOD DROP INLET PROTECTION
NOTES:
A
PLAN
B
A
B
A
ELEVATION
POINTS A SHOULD BE
HIGHER THAN POINT B
A
PROPER PLACEMENT OF SYNTHETIC SOCK BARRIERIN A DRAINAGE WAY
SINGLE ROW OF SYNTHETIC SOCKS TO BE PLACED
PRIOR TO THE START OF ROUGH GRADING
SECURELY BOUND SOCKS REQUIRED FOR
DURABILITY
2" x 2" STAKES 12"
INTO GROUND
SYNTHETIC SOCK
STAKED DOWN
4-12" WIDE STRIPS OF TALL FESCUE SOD
ON EACH SIDE OF THE DROP INLET.
COMPACTED FILL OVER TOE
OF FABRIC BURIED 4" DEEP
SHEET FLOW
(TYPICAL)
POINTS A SHOULD
BE HIGHER THAN
POINT B
THE ENTRANCE SHALL BE MAINTAINED IN A
CONDITION THAT WILL PREVENT TRACKING OR
FLOWING OF SEDIMENT ONTO PUBLIC
RIGHT-OF-WAY. THIS MAY REQUIRE TOP DRESSING,
REPAIR AND/OR CLEAN OUT OF ANY MEASURES
USED TO TRAP SEDIMENT.
WHEN NECESSARY, WHEELS SHALL BE CLEANED PRIOR TO
ENTRANCE ONTO PUBLIC RIGHT-OF-WAY.
WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN
AREA STABILIZED WITH CRUSHED STONE THAT DRAINS
INTO AN APPROVED SEDIMENT TRAP OR SEDIMENT BASIN.
BMP 1.01 TEMPORARY GRAVEL CONSTRUCTION ENTRANCE
SOURCE: VIRGINIA DIVISION OF SOIL AND WATER CONSERVATION
SOURCE: Va SWCC
PLATE 1.01a
TEMPORARY SYNTHETICSOCK SEDIMENT BARRIER
PROPER PLACEMENT OF A FILTERBARRIER IN A DRAINAGE WAY
AFTER THE CONTRIBUTING DRAINAGE AREA
HAS BEEN PERMANENETLY STABILIZED, THE
BLOCK AND GRAVEL STRUCTURE WILL BE
REMOVED AND PERMANENT SOD LAID
AROUND THE DROP INLET.
W
I
D
T
H
A
S
R
E
Q
U
I
R
E
D
FILTER FABRIC
30' R
. (T
YP
.)
LIMEROCK BASE
P
A
V
E
D
P
U
B
L
I
C
R
O
A
D
2 % O
R GREATER
50' M
IN
IM
U
M
6" M
IN
.
STRUCTURAL COURSE
2" SP-12.5
2 %
SLO
PE
O
R G
REA
TER
EXISTING
PAVED ROADW
AY
F.D.O.T. # 1 COARSE
AGGREGATE
WATER SUPPLY TO
WASH WHEELS IF
NECESSARY
DIVERSION RIDGE
REQUIRED WHERE GRADE
EXCEEDS 2 % OR GREATER
F.D.O.T. # 1 COARSE
AGGREGATE
FILTER FABRIC
UNDERLAYMENT
(FULL UNDERCOVER)
1
2
'
M
I
N
I
M
U
M
PUBLIC ROW
ASPHALTIC CONCRETE
STRUCTURAL COURSE
2" SP-12.5
ASPHALTIC CONCRETE
SINGLE ROW SILT FENCE SHALL BE ERECTED
AS SHOWN BEFORE COMMENCEMENT AND
UNTIL END OF CONSTRUCTION.
SINGLE ROW SILT FENCE SHALL BE ERECTED
AS SHOWN BEFORE COMMENCEMENT AND
UNTIL END OF CONSTRUCTION.