project name: type: notes: catalog number wave …...nat u1 u10 unv. 120-277v, 0-10v, dims to 10% u1...

2
LUX dynamics • 1350 Capital Blvd • Reno, NV 89502 • Phone: 775.200.0707 • Fax: 775.313.0888 • www.luxdynamics.com Project Name: Type: Notes: Module /HQV Cord Mounting 0-10V Dim Finish Controls Emergency Driver 850 HO2 840 835 Contact Factory if other than 120V-277V NL CA2' CP2' WA2' 3/10 4/10 5/10 6/10 3/15 4/15 5/15 6/15 'LUHFWLRQ RI Light U10 DLH D/O WCM Series WAVE 4 2' WP2' Access to Electronics TOP BOT - 2' - Voltage Option DIR IND CLD STND Standard Finish - As Shown in Photo Above CC#### Custom Color - Please Provide RAL Number DLH Daylight Harvesting Sensor OCC Occupancy Sensor (On/Off) D/O Daylight and OCC: (1) Module WCM Wireless Control Module 1 st Digit Number of Conducting Wires 2 nd Digit Length of Cord (feet) * Cord Lengths Available up to 30' 5-Wires Standard for 0-10V Dimming 4-Wires Standard for A/B Switching 3- 3-Wires Standard for On/Off TOP Lid Opens from Top BOT Lid Opens from Bottom DIR Direct Lighting: Bars Aimed Down IND Indirect Lighting: Bars Aimed Up CLD Custom Light Distribution Part # Description Light Loss NL No Lens 0.0% CA2' Clear Acrylic 10% CP2' Clear Polycarbonate 14% WA2' White Acrylic 16% WP2' White Polycarbonate 25% CRI/ CCT Application OCC Channel Config. Mfr. D - Double Channel 830 827 927 LUX D NAT U1 U10 Unv. 120-277V, 0-10V, dims to 10% U1 Unv. 120-277V, 0-10V, dims to 1% NAT Natatorium TC Tennis Court MFG/WHS Manufacturing/Warehouse GYM Gymnasium A/FH Arena/Field House ARCH Architectural TC MFG/WHS GYM A/FH ARCH CC#### STND(W) 850 80CRI CCT-5000K 840 80CRI CCT-4000K 835 80CRI CCT-3500K 830 80CRI CCT-3000K 827 80CRI CCT-2700K 927 90CRI CCT-2700K *Other CRI and CCT Available Contact Factory for Availability 0.0% 3.2% 4.3% 6.9% 22.3% Light Loss 10.1% Description Part # Custom Output For Use to Specify Critical Fixture Inputs or Outputs. Leave Blank for Fixture Performance as Shown Above. CFO Custom Fixture Output. Specify Needed Lumens. CFI Custom Fixture Input. Specify Needed Wattage. CFO CFI - WAVE - 4 - - HO2 - UX UX Unv. 120-277V, No Dimming 4-Point AC Cable up to 5' Length, Hook H4P5 4-Point AC Cable up to 10' Length, Hook H4P10 4-Point AC Cable up to 20' Length, Hook H4P20 Stainless Steel 4-Point AC Cable up to 5' Length, Hook H4P5SS Stainless Steel 4-Point AC Cable up to 10' Length, Hook H4P10SS Stainless Steel 4-Point AC Cable up to 20' Length, Hook H4P20SS Meyer's Hub 1-Point, 3/4" GRC Adapter MH1P Meyer's Hub 2-Point, 3/4" GRC Adapters MH2P Surface Mount SM * Custom Mounting Available - Contact Factory with Request * For lengths greater than 20' - Contact Factory with Request Wall Mount WM Truss Mount TM 2-Point AC Cable up to 5' Length, Hook H2P5 2-Point AC Cable up to 10' Length, Hook H2P10 2-Point AC Cable up to 20' Length, Hook H2P20 Stainless Steel 2-Point AC Cable up to 5' Length, Hook H2P5SS Stainless Steel 2-Point AC Cable up to 10' Length, Hook H2P10SS Stainless Steel 2-Point AC Cable up to 20' Length, Hook H2P20SS Catalog Number: LUX - WAVE - 4 - D - HO2- - 2' - - - - - - - - - - - Glare Guard Deflector - - See the detail sheet Online at: www.luxdynamics.com/cutsheets/WAVE/LUX deflector.pdf Deflector 2' - With Bend Glare Guard with additional light-spill control Deflector 2' - No Bend Glare guard with flat front surface for moderate light-spill control * (1) Deflector per LED Bar, fixtures may be ordered with any number and combination of deflectors. *See Deflector Specification for Details Electrical: ,QSXW 9ROWDJH 9 9 Option Available 9 'LPPLQJ 6WDQGDUG 13 /EV 5.9 kg) Warranty: )L[WXUH %RG\ <HDUV (OHFWURQLFV <HDUV Fixture Dimensions: Performance: $LUFUDIW &DEOH 6XVSHQVLRQ Pendant Mount Custom Mounting Installation: 23,602 Nominal /XPHQV 180 :DWWV 131 /XPHQV:DW LED Lifetime per TM-21: L(70) > 60,000 Hours Calculated Lifetime: L(70) > 150,968 Hours Fixture Weight: 26/ [ 16: [ 12+ 66.0FP [ 30.5FP [ FP ,I DQ\ RSWLRQV DUH QRW GHVLUHG OHDYH EODQN -Brite-Dip Anodized Aluminum Extrusions -White Powder Coated Aluminum Endcaps Standard Finish Includes (shown above): Optics: 360° Rotatable BARs for Customized Distributions Wide 120° Beam Angle for Maximum Uniformity Diffuse Lensing Available in Clear and White Optional Glare Guards for Up and Down Light, (1) per LED Bar Mechanical: Extruded Aluminum Construction Stainless Steel Hardware Isolated Driver Channels Thermally Independent Heat Sink LED BARs Anodized Brite-Dip for Superior Corrosion Resistance Ambient Temperature: -40°C to 65.5°C (-40°F to 150°F) Optional Polycarbonate or Acrylic Lenses Listings: Components: High-Output Nichia LED Chips 90°C Osram Sylvania LED Drivers ARRA Compliant (Made In America) UL1598 for Dry and Damp Locations EM (05 EM10 10 Watt EM Backup EM15 15 Watt EM Backup

Upload: others

Post on 09-Aug-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Project Name: Type: Notes: Catalog Number WAVE …...NAT U1 U10 Unv. 120-277V, 0-10V, dims to 10% U1 Unv. 120-277V, 0-10V, dims to 1% NAT Natatorium TC Tennis Court MFG/WHS Manufacturing/Warehouse

LUX dynamics • 1350 Capital Blvd • Reno, NV 89502 • Phone: 775.200.0707 • Fax: 775.313.0888 • www.luxdynamics.com

Project Name: Type: Notes:

Module Cord Mounting0-10VDim Finish Controls Emergency

Driver850HO2840835

ContactFactoryif other than 120V-277V

NLCA2'CP2'WA2'

3/104/105/106/103/154/155/156/15

LightU10 DLH

D/OWCM

SeriesWAVE

Numberof Bars

4

Length2'

WP2'

Access to Electronics

TOPBOT

- 2' -

VoltageOption

DIRINDCLD

STND Standard Finish - As Shown in Photo AboveCC#### Custom Color - Please Provide RAL Number

DLH Daylight Harvesting SensorOCC Occupancy Sensor (On/Off)D/O Daylight and OCC: (1) Module

WCM Wireless Control Module

1st Digit Number of Conducting Wires2nd Digit Length of Cord (feet)

** Cord Lengths Available up to 30'5-Wires Standard for 0-10V Dimming4-Wires Standard for A/B Switching 3-3-Wires Standard for On/Off

TOP Lid Opens from TopBOT Lid Opens from Bottom

DIR Direct Lighting: Bars Aimed DownIND Indirect Lighting: Bars Aimed Up

CLD Custom Light Distribution

Part # Description Light LossNL No Lens 0.0%

CA2' Clear Acrylic 10%CP2' Clear Polycarbonate 14%

WA2' White Acrylic 16%WP2' White Polycarbonate 25%

CRI/CCT Application

OCC

ChannelConfig.Mfr.D - Double Channel

830827927

LUX D

NATU1

U10 Unv. 120-277V, 0-10V, dims to 10%U1 Unv. 120-277V, 0-10V, dims to 1%

NAT Natatorium TC Tennis Court

MFG/WHS Manufacturing/WarehouseGYM GymnasiumA/FH Arena/Field House

ARCH Architectural

TCMFG/WHSGYMA/FHARCH

CC####STND(W)

850 80CRI CCT-5000K840 80CRI CCT-4000K835 80CRI CCT-3500K830 80CRI CCT-3000K827 80CRI CCT-2700K927 90CRI CCT-2700K

*Other CRI and CCT AvailableContact Factory for Availability

0.0%3.2%4.3%6.9%

22.3%

Light Loss

10.1%

DescriptionPart #

CustomOutput

For Use to Specify Critical Fixture Inputs or Outputs. Leave Blank for Fixture Performance as Shown Above.CFO Custom Fixture Output. Specify Needed Lumens.CFI Custom Fixture Input. Specify Needed Wattage.

CFOCFI

- WAVE - 4 - - HO2 -

UX

UX Unv. 120-277V, No Dimming

4-Point AC Cable up to 5' Length, HookH4P54-Point AC Cable up to 10' Length, HookH4P104-Point AC Cable up to 20' Length, HookH4P20Stainless Steel 4-Point AC Cable up to 5' Length, HookH4P5SSStainless Steel 4-Point AC Cable up to 10' Length, HookH4P10SSStainless Steel 4-Point AC Cable up to 20' Length, HookH4P20SSMeyer's Hub 1-Point, 3/4" GRC AdapterMH1PMeyer's Hub 2-Point, 3/4" GRC AdaptersMH2PSurface Mount SM

* Custom Mounting Available - Contact Factory with Request * For lengths greater than 20' - Contact Factory with Request

Wall Mount WMTruss Mount TM

2-Point AC Cable up to 5' Length, HookH2P52-Point AC Cable up to 10' Length, HookH2P102-Point AC Cable up to 20' Length, HookH2P20Stainless Steel 2-Point AC Cable up to 5' Length, HookH2P5SSStainless Steel 2-Point AC Cable up to 10' Length, HookH2P10SSStainless Steel 2-Point AC Cable up to 20' Length, HookH2P20SS

Catalog Number: LUX - WAVE - 4 - D - HO2- - 2' - - - - - - - - - --

Glare GuardDeflector

- -

See the detail sheet Online at:www.luxdynamics.com/cutsheets/WAVE/LUX deflector.pdf

Deflector 2' - With Bend Glare Guard with additional light-spill control

Deflector 2' - No Bend Glare guard with flat front surface for moderate light-spill control

* (1) Deflector per LED Bar, fixtures may be ordered with any number and combination of deflectors.

*See Deflector Specificationfor Details

Electrical:Option Available

13 5.9 kg)

Warranty:

Fixture Dimensions:

Performance:

Pendant MountCustom Mounting

Installation:

23,602 Nominal 180 131 LED Lifetime per TM-21: L(70) > 60,000 Hours Calculated Lifetime: L(70) > 150,968 Hours

Fixture Weight:

26 16 12 66.0 30.5-Brite-Dip Anodized Aluminum Extrusions-White Powder Coated Aluminum Endcaps

Standard Finish Includes (shown above):

Optics:360° Rotatable BARs for Customized Distributions Wide 120° Beam Angle for Maximum Uniformity Diffuse Lensing Available in Clear and WhiteOptional Glare Guards for Up and Down Light, (1) per LED Bar

Mechanical:Extruded Aluminum Construction Stainless Steel Hardware Isolated Driver Channels Thermally Independent Heat Sink LED BARs Anodized Brite-Dip for Superior Corrosion Resistance

Ambient Temperature: -40°C to 65.5°C (-40°F to 150°F) Optional Polycarbonate or Acrylic Lenses

Listings:

Components:High-Output Nichia LED Chips 90°C Osram Sylvania LED Drivers

ARRA Compliant (Made In America) UL1598 for Dry and Damp Locations

EM5

EM10 10 Watt EM Backup

EM15 15 Watt EM Backup

Page 2: Project Name: Type: Notes: Catalog Number WAVE …...NAT U1 U10 Unv. 120-277V, 0-10V, dims to 10% U1 Unv. 120-277V, 0-10V, dims to 1% NAT Natatorium TC Tennis Court MFG/WHS Manufacturing/Warehouse

1350 Capital Blvd Reno, NV 89502 Phone: 775.200.0707 Fax: 775.313.0888

Option/Adder DataContact factory for detailed specification sheets on each option/adder. Every option/adder available in 347/480V, contact factory.

Control Type PIR/Photocell 1-10V Ambient Temperature 5°C to 55°CMounting Height 8' to 40'

Daylight Harvesting & Occupancy Sensor- DimControl Type Photocell 1-10VAmbient Temperature 5°C to 55°CMounting Height 8' to 40'

Daylight Harvesting Sensor - DimControl Type PIR Line Voltage Ambient Temperature -10°C to 71°CMounting Height 15' to 45'

Occupancy Sensor - On/OffQuantity Needed Per Fixture 1Ambient Temperature -40°C to 55°CPhone Application Available

Wireless Control Module

Ambient Temperature -40°C to 100°CQuantity Needed Per Fixture 1

347/480Volt Step-Down Transformer

TEST #:TEST LAB: TEST CATALOG:

LLI-17199-6LIGHTLAB INTERNATIONAL (WWW.LIGHTLABINT.COM)LUX-WAVE-4-D-HO2-850-2'-U10-CA2'

INPUT WATTAGE: 180.4MAX CD: 4,523.3 AT HORIZONTAL: 0°, VERTICAL: 136.5°

ZONAL LUMEN SUMMARYZONE LUMENS % LUMINAIRE0-30 1,071.7 5%0-40 1,851.2 8.6%0-60 3,873.8 18%60-90 3,707.7 17.3%70-100 3,890.0 18.1%90-120 4,696.6 21.9%0-90 7,581.5 35.3%90-180 13,880.4 64.7%0-180 21,461.9 100%

LCS TABLEBUG RATING B3 - U5 - G5FORWARD LIGHT LUMENS LUMENS %

LOW(0-30): 392.6 1.8%MEDIUM(30-60): 1,181.7

HIGH(60-80): 1,326.3VERY HIGH(80-90): 856.9

5.5%6.2%

4%BACK LIGHT

LOW(0-30): 679.2 3.2%MEDIUM(30-60): 1,620.0 7.5%

HIGH(60-80): 1,090.6 5.1%VERY HIGH(80-90): 435.5 2%UPLIGHT

6.3%58.4%

LOW(90-100): 1,353.7HIGH(100-180): 12,523.0

TRAPPED LIGHT: 2.3 0%

Initial Lumen Output 1626 Lumens Per BarAmbient Temperature 0°C to 55°CIllumination Time 90 Minutes

Emergency Battery (12-Watt)Initial Lumen Output 1355 Lumens Per BarAmbient Temperature 0°C to 55°CIllumination Time 90 Minutes

Emergency Battery (10-Watt)

Standard Bar Configuration,as Tested.