product pocket catalog
TRANSCRIPT
NEW - Now Featuring H eF Series® Residential & Light Duty Commercial H ElectriFLEX HD™
Built to be the Best™
P R O D U C T P O C K E T C A T A L O G
AMERICAM A D E I N
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Visit us on the web at: www.bradfordwhite.comAmbler, PA
Bradford White Corporation Subsidiary Companies
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
For questions regarding where to purchase water heaters or who your local Bradford White representative is, contact the Sales Department:800-523-2931 • Fax: 215-641-1670
For questions regarding tank and/or parts warranty and limitations on warranties, contact our24/7 Warranty Support:800-531-2111 • Fax: 269-795-1089email: [email protected]
For technical questions during and after installation such as how to diagnose and/or solve issues in the field, contact our24/7 Technical Support: 800-334-3393 • Fax: 269-795-1089email: [email protected]
For product sizing, performance, application, and clarification questions before installation, contact theProduct Department:844-235-4958email: [email protected]
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
ContentsResidential Water HeatersGASAtmospheric Vent High EF ............................................................................. 6/7Atmospheric Vent Damper ............................................................................. 8/9Atmospheric Vent Models .......................................................................... 10/11Atmospheric Vent High Input ..................................................................... 12/13Direct Vent ................................................................................................. 14/15High Efficiency eF Series® Power Vent ...................................................... 16/17Power Vent (TTW®) ................................................................................... 18/19Power Direct Vent ...................................................................................... 20/21Manufactured Home Closed Combustion/Direct Vent ................................ 22/23Manufactured Home Atmospheric Combustion ......................................... 24/25Ultra Low NOx Atmospheric Vent Damper ................................................. 26/27Ultra Low NOx Atmospheric Vent .............................................................. 28/29Ultra Low NOx Atmospheric Vent High Input ............................................ 30/31Ultra Low NOx TTW® Power Vent .............................................................. 32/33Ultra Low NOx Power Direct Vent .............................................................. 34/35Ultra Low NOx Direct Vent ......................................................................... 36/37Infiniti Tankless™ High Efficiency ............................................................... 38/39Infiniti Tankless™ Mid Efficiency ................................................................. 40/41
ELECTRICGeneral Information ................................................................................... 42/43AeroTherm™ Series Heat Pump .................................................................. 44/45Upright Models .......................................................................................... 46/47Lowboy Models ......................................................................................... 48/49Wall Hung .................................................................................................. 50/51Utility ......................................................................................................... 52/53Powerful Compact®.................................................................................... 54/55KwickShot® Instantaneous Water Heaters ................................................. 56-59
SOLAREcoStor2™ Double-Wall Gas Backup .......................................................... 60/61EcoStor2™ TTW® Power Vent Double-Wall Gas Backup............................. 62/63EcoStor™ Open Loop Gas Backup .............................................................. 64/65EcoStor™ TTW® Power Vent Open Loop Gas Backup................................. 66/67EcoStor2™ SC Ultra Low NOx Double-Wall Gas Backup ............................ 68/69EcoStor™ Dual Coil Heat Exchanger Backup ............................................... 70/71EcoStor™SC Single-Wall Electric Backup.................................................... 72/73EcoStor2™ Double-Wall Electric Backup Models ........................................ 74/75Solar Saver® Electric Backup ..................................................................... 76/77
HYDRONIC SPACE HEATINGCombi1™ Single-Wall Atmospheric ............................................................ 78/79Combi1™ TTW® Single-Wall Power Vent Models ....................................... 80/81Combi2™ Double-Wall Atmospheric Models .............................................. 82/83Combi2™ TTW® Double-Wall Power Vent................................................... 84/85
INDIRECTSPowerStor Series® Single-Wall Indirect ..................................................... 86/87PowerStor2™ Series Double-Wall Indirect .................................................. 88/89Powertor Series® SS Stainless Steel Single-Wall Indirect ......................... 90/91
STORAGE TANKSStorage Tank .............................................................................................. 92/93
Commercial Water HeatersGASLight Duty Atmospheric Vent High Input ................................................... 96/97Light Duty High Efficiency eF Series® Power Vent ..................................... 98/99Light Duty TTW® Power Vent ................................................................ 100/101Light Duty Power Direct Vent ................................................................ 102/103Light Duty Direct Vent ........................................................................... 104/105Light Duty Ultra Low NOx Atmospheric Vent High Input ....................... 106/107
Light Duty Ultra Low NOx Direct Vent ................................................... 108/109Light Duty Ultra Low NOx TTW® Power Vent ........................................ 110/111Light Duty Ultra Low NOx Power Direct Vent ........................................ 112/113Commander Series™ Atmospheric Vent ................................................. 114/115Electronic Ignition Water Heaters .......................................................... 116-119Induced Draft ......................................................................................... 120/121Millivolt .................................................................................................. 122-125Ultra High Efficiency Models .................................................................. 126-129
ELECTRICGeneral Information ............................................................................... 130/131ElectriFLEX LD™ (Light Duty) Upright .................................................... 132/133ElectriFLEX LD™ (Light Duty) Lowboy .................................................... 134/135ElectriFLEX LD™ (Light Duty) Utility ....................................................... 136/137ElectriFLEX LD™ (Light Duty) Wall Hung ................................................ 138/139ElectriFLEX MD™ (Medium Duty) ........................................................... 140/141ElectriFLEX HD™ (Heavy Duty) ............................................................... 142/143Surface and Immersion Thermostat Models .......................................... 144/145ASME Models ........................................................................................ 146/147Brute Vertical Round .............................................................................. 148/149GPH Recovery Table for kW Input ......................................................... 150/151
INDIRECTSPowerStor Series® Single-Wall Indirect ................................................ 152/153
STORAGE TANKSJacketed Storage Tank ........................................................................... 154/155Large Volume Jacketed Storage Tank .................................................... 156-159Large Volume Unjacketed Storage Tank ................................................ 160-163Large Volume Vertical Topcoat Storage Tank Models ........................... 164-167
Warranty Information ..............................................................................168Tank Type Serial Number Indentification ...........................................169
1. All Gas Water Heaters are design certified by CSA International (formerly AGA and CGA) in accordance with ANSI Z21.10.1 or 10.3 (latest addition). Closed Combustion Manufactured Home Water Heaters, are listed by Intertek (ETL).
2. All Electric Water Heaters are listed by Intertek (ETL).
3. All Residential Storage Models meet or exceed efficiency requirements of the Department of Energy. ASHRAE standard 90.1b (current standard) and the National Appliance Energy Conservation Act of 1987, recent amendment effective April 16, 2015 which supercedes all state and local efficiency requirements.
4. All Tank Type Water Heaters are certified at 300 PSI test pressure and 150 PSI working pressure (except where noted).
5. All Residential and Light Duty Water Connections are 3⁄4" NPT on 8" centers (except where noted).
6. All Residential and Light Duty Gas Models have 1⁄2" NPT Gas Connections (except where noted).
7. All Residential Water Heaters come with a T&P Relief Valve included (except where noted).
8. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012.
9. All dimensions are in inches (unless otherwise noted). Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
10. All products manufactured by Bradford White Water Heaters are designed, fabricated, and assembled in Middleville, MI. All raw materials and component parts are sourced from American companies for the highest level of American made content and manufacture, whenever possible.
CSA International National Sanitation Foundation
American Society of Mechanical Engineers Heating Boilers
American Society of Mechanical Engineers Lined Potable Water Heaters
National Board of Boiler and Pressure Vessel Inspectors
Air-Conditioning, Heating, and Refrigeration Institute
Compliance, Safety, Accountability
Intertek Underwriters Laboratories
General Information About the Products in this Catalog
page 2
page 3
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
The Family of Hydrojet® Systems This Is Technology That Works!
Hydrojet® Total Performance SystemThe Hydrojet® Total Performance System is a cold-water delivery tube that reduces sediment buildup and thoroughly mixes incoming water with stored water reducing thermal stratification. The secret is a series of flow altering “jet ports”. These ports create counter-rotation and dynamic turbulence that effectively blasts sediment into suspension and prevents its accumulation.
The Hydrojet® Total Performance System also causes more efficient temperature mixing inside the tank. Heating efficiency and usable hot water delivery are greatly increased, thereby saving energy and money.
The upper “jet ports” direct the flow outward to begin the dynamic mixing action.
The Hydrojet® System’s jet ports create a churning outflow that puts sediment into suspension. This turbulent action helps reduce sediment and prevent its accumulation.
The Family of Hydrojet® Systems This Is Technology That Works!
The lower “jet ports” direct the flow inward to increase pressure and turbulence.
Commercial Hydrojet® Sediment Reduction System The commercial Hydrojet® was designed to block the build-upof harmful sediment in commercial units by increasingturbulence with accelerated water current inside the tank.It incorporates up to two inlet tubes. One is the traditional topconnect version and the other is a front connection configuration.
Hydrojet®2 Total Performance SystemMuch like the original Hydrojet® Total Performance System, this cold water inlet device minimizes sediment build up, increases delivery and reduces thermal stratification. The Hydrojet®2 is specifically designed for higher input applications. It utilizes additional jetports to initiate beneficial temperature mixing higher in the tank thereby increasing usable hot water.
“Make the Switch to Bradford White”
page 4
page 5
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
B
J
H
C
A
G
E
D
F
B
J
H
C
A
G
E
D
F
Photo ofRG2F40S6N
Residential GasAtmospheric Vent High EF Models
6/7
l ENERGY STAR® Qualifiedl High Efficiency Blower
- 10 ft. Power Cord Included (120 VAC)l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control
System - Intelligent Diagnostics - Separate Immersed Thermowelll Defender Safety System® featuring
the patented Advanced ScreenLok® Technology flame arrestor design
- Flammable Vapor Sensor - Maintenance-Free - Sight Window - Pedestal Basel Hydrojet® Total Performance Systeml Vitraglas® Liningl 2" Non-CFC Foam Insulationl Water Connections—3⁄4" NPT
true dielectric fittings
l Heat Trapsl Protective Magnesium Anode Rodl 3"x4" “Snap Lock” Draft Diverterl T&P Relief Valvel Low Restriction Brass Drain Valve
38,00038,000
4050
� RG2F40S6N� RG2F50S6N
7084
541/4551/4
2224
40405/8
150176
113/4113/4
3 x 43 x 4
NATURAL GAS AND LIQUID PROPANE GAS MODELS Recovery90°F Rise*
A
Floor toFlue Conn.
1st HourRating(Gal.)
0.700.70
EnergyFactor
4141
U.S.GPH
3333
Imp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
4748
F
Floor toTop ofHeater
477/8487/8
G
Floor toWaterConn.
257/8277/8
H
Depth
88
J
C/Lof WaterConns.
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. 120V, 60Hz. 1 Amp. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.H = ENERGY STAR® Qualified.
Atmospheric Vent High EF Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES
page 6
page 7
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
B
JH
A
G
F
E
D
C
B
JH
A
G
F
E
D
CPhoto of
RG2D40S6N
Residential GasAtmospheric Vent Damper Models
8/9
l ENERGY STAR® Qualified—Some modelsl Bradford White ICON System™
- Enhanced Performance - Advanced Temperature
Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Automatic Flue Damper
- 10 ft. Power Cord Included (120 VAC)l Defender Safety System® featuring the
patented Advanced ScreenLok® Technology flame arrestor design
- Flammable Vapor Sensor - Maintenance-Free - Sight Window - Pedestal Basel Hydrojet® Total Performance Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connections—3⁄4" NPT true dielectric
fittingsl Heat Traps
l Protective Magnesium Anode Rodl 3"x4" “Snap Lock” Draft Diverterl T&P Relief Valvel Low Restriction Brass Drain Valve
32,00040,00040,00040,00038,00040,000
304040504050
RG1D30T6N• RG1D40S6N• RG1D40T6N• RG1D50T6N•� RG2D40S6N� RG2D50S6N
587476897286
63577/8633/8633/8541/2631/2
162018202222
497/841
501/8497/8407/8497/8
116147134160155174
13131313
113/4113/4
3 x 43 x 43 x 43 x 43 x 43 x 4
NATURAL GAS MODELS Recovery90°F Rise*
A
Floor toFlue Conn.
1st HourRating(Gal.)
0.650.620.620.600.670.67
EnergyFactor
344343434143
NatU.S.GPH
283636363436
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
561/448
569/16
569/16
4711/16
561/2
F
Floor toTop ofHeater
57491/8573/4573/4487/858
G
Floor toWaterConn.
203/4243/4223/4243/4261/8261/8
H
Depth
88881111
J
C/L ofWaterConn.
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. 120V, 60Hz. 12 Amps. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.H = ENERGY STAR® Qualified.
• Models feature optional top T&P location and must be specified when ordering. RG1D30T6X• RG1D40S6X• RG1D40T6X• RG1D50T6X•� RG2D40S6X� RG2D50S6X
LP GAS MODELS InputBTU/Hr.
31,00038,00038,00038,00038,00040,000
Recovery90°F Rise*
334141414143
LPU.S.GPH
283434343436
LPImp.GPH
ModelNumber
Atmospheric Vent Damper Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES
page 8
page 9
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
A
F
D
E
F
B
8"
C
G
A
F
D
E
F
B
8"
C
G
Photo ofRG240T6N
l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature
Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Defender Safety System® featuring the patented
Advanced ScreenLok® Technology flame arrestor design
- Resettable Thermal Switch - Maintenance-Free - Sight Window - Pedestal Basel Hydrojet® Total Performance Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connections—3⁄4" NPT true
dielectric fittingsl Heat Trapsl Protective Magnesium Anode Rodl 3"x4" “Snap Lock” Draft Diverter
l T&P Relief Valve l Low Restriction Brass Drain Valve
Residential GasAtmospheric Vent Models
10/11
27,00032,00030,00034,00040,00040,00034,00040,00040,00050,000
30303040404050504850
RG130T6N•RG230T6N•RG230S6NRG140T6N•RG240T6N•RG240S6N•RG150T6N•RG250T6N•RG250L6NRG250S6N•
52585670767482898893
591/8593/4491/4611/4601/8511/2595/8601/2515/8601/2
191/2211/2231/2211/2231/2251/2231/2251/2271/2251/2
16182018202220222422
493/4 / 563/8497/8 / 563/8
385/8511/2 / 60
501/8 / 565/841 / 471/450 / 563/8497/8 / 57
405/8497/8 / 57
109116113132134139150154170167
13131313131313131313
3 x 43 x 43 x 43 x 43 x 43 x 43 x 43 x 43 x 4
4
Atmospheric Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed79% Recovery Efficiency
Recovery 90°F Rise* A
Floor toFlue Conn.
1st HourRating(Gal.)
0.630.640.630.620.620.620.600.620.600.60
EnergyFactor
29343237434337434354
NatU.S.GPH
24283731363631363645
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
G
Depth
DFloor to
T&PConn.
EFloor to
GasConn.
571/2571/8461/2595/8579/16
493/16
58577/8493/8583/16
FFloor toWaterConn.
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency.• Models feature optional top T&P location and must be specified when ordering. Note: RG230S6N and RG250L6N do not have top T&P option. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
RG130T6X•RG230T6X•RG230S6XRG140T6X•RG240T6X•RG240S6X•RG150T6X•RG250L6XRG250T6X•RG250S6X•
LP GAS MODELS Input BTU/Hr.
27,00031,00032,00034,00036,00035,00034,00035,00035,00048,000
Recovery 90°F Rise*
29333237344137414152
LP U.S. GPH24232731333431343445
LP Imp. GPHModel Number
Atmospheric Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed79% Recovery EfficiencyDIMENSIONS IN INCHES
page 10
page 11
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofRG2100H6N
K
B
C
A
JF
E
D&M
L
NN
H
RG2100H6N
A
D&M
E
J F
B
H
N N
C
K
L
RG250H6N / RG275H6N
KB
C
J
F
E L
A
D&M
H
N N
RG155H6N
Residential GasAtmospheric Vent High Input Models
12/13
All Model Features (except RG155H6N):l Bradford White ICON
System™
- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell
All Model Features:l Hydrojet 2™ Total
Performance Systeml Vitraglas® Liningl Side Connections—3/4"
(19mm)l Non-CFC Foam Insulationl Pedestal Base
(RG250H6N / RG275H6N only)
l Water Connections
l Hand Hole Cleanout (RG2100H6N only)
l Protective Magnesium Anode Rod
l 4" (107mm) “Snap Lock” Draft Diverter
l T&P Relief Valvel Low Restriction Brass
Drain Valvel Thermostatic
Mixing Valve (ASSE Approved)—Included with RG155H6N only
65,00080,00076,00085,000
485575100
RG250H6NRG155H6NRG275H6NRG2100H6N
110N/AN/AN/A
60591/2625/869
222226
281/4
4915/16
497/8517/8595/16
189210249413
131413/16
15157/16
4444
NATURAL GAS MODELS Recovery90°F Rise*
A
Floor to Flue Conn.
1st HourRating(Gal.)
0.60N/AN/AN/A
EnergyFactor
70868292
NatU.S.GPH
58726877
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
565/85515/16
59651/2
F
Floor toTop ofHeater
1181116
H
C/L ofWaterConn.
577/8577/8607/16
6615/16
J
Floor toWaterConn.
26257/8271/4311/2
K
Depth
131/2157/16
165/81711/16
L
Floor toSpace
Heating Inlet
4915/16
497/8517/8505/8
M
Floor toSpace
Heating Outlet3/43/41
11/4
N
NPT
Approx.Shipping
Weight (lbs)
* Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6” to “10”. RG155H6N not available as 10 year model. RG2100H6N model features hand hole cleanout. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
RG250H6XRG155H6XRG275H6XRG2100H6X
LP GAS MODELS InputBTU/Hr.
61,00078,00076,00088,000
Recovery90°F Rise*
66848295
LPU.S.GPH
55706879
LPImp.GPH
ModelNumber
Atmospheric Vent High Input Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES
page 12
page 13
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
J
H
F
E L
B
D&MK
C C
A A
K
Flexible Vent Kit (Side View)Telescoping Solid Vent Kit (Side View)
Photo ofRG2DV50H6N
Residential GasDirect Vent Models
14/15
l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature
Control System - Intelligent Diagnostics
- Separate Immersed Thermowelll Defender Safety System® featuring
the patented Advanced ScreenLok® Technology flame arrestor design
- Resettable Thermal Switch - Maintenance-Free - Sight Window - Pedestal Basel Closed Combustionl Reinforced Sealsl Maintenance-Freel Sight Windowl Hydrojet® Total Performance Systeml Vitraglas® Liningl Cast Aluminum Air Intake Bootl Telescoping Solid Vent Kitsl Flexible Vent Kit
l Side Connections—3/4" NPT tappings (RG2DV50H6N only)
l 2" Non-CFC Foam Insulationl Water Connections—3/4" NPT—
True dielectric fittings
l Heat Trapsl Protective Magnesium Anode Rodl T&P Relief Valvel Low Restriction Brass Drain Valve
38,00042,00050,000
405048
RG2DV40S6NRG2DV50S6NRG2DV50H6N
738893
631/2 min.
721/2 min.
757/8 min.
222222
433/8521/4521/4
189212234
151515
334
556
NATURAL GAS MODELS Recovery90°F Rise*
A
Floor to C/L of Vent
1st HourRating(Gal.)
0.620.600.60
EnergyFactor
414554
U.S.GPH
343545
Imp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
I.D. O.D.
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
503/16
593/16
591/8
F
Floor toTop ofHeater
8118
H
C/L ofWaterConn.
511/8601/8601/8
J
Floor toWaterConn.
313131
K
Depth
——
153/4
L
Floor toSpace
Heating Inlet
——
521/4
M
Floor toSpace
Heating Outlet
Approx.Shipping
Weight (lbs)
All Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”.For 10 year models, change suffix from “6” to “10”. *Based on manufacturer’s rated recovery efficiency.Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
RG2DV40S6N / RG2DV50S6N Solid Vent Kit: Part No. 239-51283-00. RG2DV40S6N / RG2DV50S6N Flexible Vent Kit: Part No. 239-51284-00.RG2DV50H6N Solid Vent Kit: Part No. 239-51286-00. RG2DV50H6N Flexible Vent Kit: Part No. 239-51287-00.Kits can be ordered and shipped with water heater, or ordered and shipped separately. For vent kit components and venting instructions, refer to Installation and Operation Manual. RG2DV40S6N / RG2DV50S6N Optional Telescoping Solid Vent Kits: Kit “A” Telescopes from 43⁄4" to 511⁄16" Part No. 239-41260-00 Kit “B” Telescopes from 61⁄2" to 93⁄16" Part No. 239-41331-00 Kit “C” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-41029-00 Kit “D” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-41424-00 RG2DV50H6N Optional Telescoping Solid Vent Kits:Kit “F” Telescopes from 43⁄4" to 511⁄16" Part No. 239-42516-00Kit “G” Telescopes from 61⁄2" to 93⁄16" Part No. 239-42517-00Kit “H” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-42514-00Kit “I” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-42512-00
RG2DV40S6XRG2DV50S6XRG2DV50H6X
LP GAS MODELS InputBTU/Hr.
36,00040,00048,000
Recovery90°F Rise*
394350
U.S.GPH
323642
Imp.GPH
ModelNumber
Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES
page 14
page 15
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
C
A
G
F
E J
B
D & K
H
8"
Photo ofRC2PV50H6N
C
A
G
F
E J
B
D & K
H
8"
Residential GasHigh Efficiency eF Series® Power Vent Model 90%+ Thermal Efficiency
16/17
l Vertical, Dual-pass Heat Exchanger System
l Vitraglas® Protection—On both primary and secondary heat exchanger
l Self-priming Condensate Teel Power Ventl Horizontal and Vertical Ventingl Bradford White ICON System™
- Enhanced Performance - Advanced Temperature
Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Hydrojet® Total
Performance Systeml Vitraglas® Liningl 2" Non-CFC Foam Insulationl Pedestal Basel Water Connections—3/4" NPTl 3/4" NPT Side Connections.
l Heat Trapsl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valve
2"Vent Pipe
3"Vent Pipe
4"Vent PipeRC2PV50H6N
†50 ft.7 ft.45 ft.40 ft.35 ft.
†120 ft.15 ft.115 ft.110 ft.105 ft.
†180 ft.15 ft.175 ft.170 ft.165 ft.
123
Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows
Subtract 5ft. for each additional 90° elbow.† For high altitude installations, consult the installation instructions.
76,00050RC2PV50H6N 671/4 24 461/2 225135/82, 3 or 4
NATURAL GAS AND LIQUID PROPANEGAS MODELS
Recovery90°F Rise*
Floor to Vent Conn.
93
U.S.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
Jacket Dia.
VentSize
Floor to T&P
Conn.
Floor toGas
Conn.
561/4
Floor toTop ofHeater
571/2
Floor toWaterConn.
273/8Depth
155/8
Floor toSpace
Heating Inlet
461/2
Floor toSpace
Heating Outlet
A B C D E F G H J K
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.* Based on 90.5% Thermal Efficiency.
High Efficiency eF Series® Power Vent Model 90%+ Thermal EfficiencyMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES
page 16
page 17
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofRG2PV50H6N
B
H
K
C
J
F
E L
A
D&M
B
H
K
C
J
F
E L
A
D&M
Residential GasPower Vent (TTW®) Models
18/19
l ENERGY STAR® Qualified—Some modelsl Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Power Vented Water Heaterl Powerful Blower Motor
- 10 ft. Power Cord Included (120 VAC)l Horizontal and Vertical Ventingl Defender Safety System® featuring the
patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Flammable Vapor Sensor
- Maintenance-Free - Sight Window - Pedestal Basel Hydrojet® Total Performance Systeml Vitraglas® Lining
l Non-CFC Foam Insulationl Water Connections—3/4" NPTl 3/4" NPT Side Connections (RG2PV50H6N,
RG1PV55H6N, and RG2PV75H6N only)l Heat Trapsl Protective Magnesium Rod (RG1PV55H6N
has two)l T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve (ASSE Approved)
—Included with RG1PV55H6N only
40,00040,00040,00040,00065,00078,00076,000
40504050485575
RG1PV40S6N RG1PV50S6N� RG2PV40T6N� RG2PV50T6N� RG2PV50H6N RG1PV55H6N RG2PV75H6N
72867286112N/AN/A
575/16
581/4 667/8
667/8
661/8
643/16
697/16
20222022222226
40405/85050
501/8
4715/16
511/2
140166146173187219260
113/4113/4113/4113/4113/4111/2131/2
2 or 32 or 32 or 32 or 33 or 43 or 43 or 4
NATURAL GAS MODELS Recovery90°F Rise*
A
Floor to VentConn.
1st HourRating(Gal.)
0.660.650.700.700.70N/AN/A
EnergyFactor
43434343708482
NatU.S.GPH
36363636587068
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
471/2481/4563/4563/4563/8545/8591/2
F
Floor toTop ofHeater
888811811
H
C/L ofWaterConn.
49501/25858
573/456
603/4
J
Floor toWaterConn.
277/8263/4241/2261/2263/4261/2301/4
K
Depth
N/AN/AN/AN/A131/2133/8133/8
L
Floor toSpace
Heating Inlet
N/AN/AN/AN/A501/8
4715/16
511/2
M
Floor toSpace
Heating Outlet
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year models, change suffix from “6” to “10”. RG1PV55H6N not available as 10 year model.*Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC 60HZ 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.H = ENERGY STAR® Qualified.
2" Vent Pipe
RG1PV40S6NRG1PV50S6NRG2PV40T6NRG2PV50T6N
†50 ft.7 ft.45 ft.40 ft.35 ft.
3" Vent Pipe
†120 ft.15 ft.115 ft.110 ft.105 ft.
3" Vent Pipe
RG2PV50H6NRG1PV55H6NRG2PV75H6N
†60 ft.7 ft.55 ft.50 ft.45 ft.
4" Vent Pipe
†180 ft.15 ft.175 ft.170 ft.165 ft.
123
Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows
2" Vent Pipe
RG2PV40T6NRG2PV50T6N
†50 ft.7 ft.45 ft.40 ft.35 ft.
3" Vent Pipe
†120 ft.15 ft.115 ft.110 ft.105 ft.
RG1PV40S6X RG1PV50S6X� RG2PV40T6X� RG2PV50T6X� RG2PV50H6X RG1PV55H6X RG2PV75H6X
LP GAS MODELS InputBTU/Hr.
38,00038,00040,00040,00058,00078,00075,500
Recovery90°F Rise*
41414343628481
LPU.S.GPH
34343636527067
LPImp.GPH
ModelNumber
† For high altitude installations, consult the installation instructions.
Power Vent (TTW®) Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES
page 18
page 19
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofRG2PDV40S6N
K
C
J F
EL
B
D & M
A H
K
C
J F
EL
B
D & M
A H
Residential GasPower Direct Vent Models
20/21
l ENERGY STAR® Qualified—Some models
l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature
Control System - Intelligent Diagnostics
- Separate Immersed Thermowell
l Defender Safety System®
- Flammable Vapor Sensor - Maintenance-Free
- Sight Window - Pedestal Basel Closed Combustion
Venting Systeml Powerful Blower Model
- 10 ft. Power Cord Included (120 VAC)
l Cast Aluminum Air Intake Bootl Horizontal and Vertical Venting
l Optional Concentric Vent Kit Termination
l Flammable Vapor Sensor (except RG2PDV75)
l Hydrojet® Total Performance System
l Vitraglas® Liningl 2" Non-CFC Foam Insulationl Water Connections— 3⁄4" NPTl Side Connections— 3/4"
NPT (RG2PDV50H6N and RG2PDV75H6N only)
l Heat Trapsl Protective Magnesium
Anode Rodl T&P Relief Valvel Low Restriction Brass
Drain Valve
40,00040,00060,00080,000
40504875
H RG2PDV40S6NH RG2PDV50S6NH RG2PDV50H6N RG2PDV75H6N
7286100—
5911/16
607/86972
22242226
421/2
431/2
521/4541/4
161192204291
1414
135/8161/4
2 or 32 or 33 or 43 or 4
Power Direct Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery Efficiency
Recovery90°F Rise*
A
Floor toExhaustOutlet
1st HourRating(Gal.)
0.700.700.68—
EnergyFactor
43436586
NatU.S.GPH
36365472
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
491/2501/2583/4623/4
F
Floor toTop ofHeater
593/8603/867
703/8
H
Floor toAir
Intake
5013/16
5113/16
60633/4
J
Floor toWaterConn.
301/2321/2305/836
K
Depth
——
153/419
L
Floor toSpace
Heating Inlet
——
521/4541/4
M
Floor toSpace
Heating Outlet
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 10 year model, change suffix “6” to “10”. * Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.H = ENERGY STAR® Qualified.
INTAKE/COMBUSTION
AIR
RAINCAP
VENTEXHAUST
A
Concentric Vent Kit Termination
2" Kit
P/N 239-44069-02 29 1/4
A (in.)
3" Kit
P/N 239-44069-01 36 1/4
A (in.)
2" Vent PipeRG2PDV40S6NRG2PDV50S6N
35 ft.35 ft.7 ft.30 ft.25 ft.20 ft.
123
Max. Intake LengthMax. Exhaust LengthMin. Vent LengthNumberof90° Elbows
3" Vent PipeRG2PDV40S6NRG2PDV50S6N
RG2PDV50H6NRG2PDV75H6N
85 ft.85 ft.7 ft.80 ft.75 ft.70 ft.
60 ft.60 ft.7 ft.
55 ft.50 ft.45 ft.
4" Vent PipeRG2PDV50H6NRG2PDV75H6N
100 ft.100 ft.7 ft.
95 ft.90 ft.85 ft.
H RG2PDV40S6XH RG2PDV50S6XH RG2PDV50H6X RG2PDV75H6X
LP GAS MODELS InputBTU/Hr.
38,00038,00060,00078,000
Recovery90°F Rise*
41416584
34345470
LPU.S.GPH
LPImp.GPH
ModelNumber
Power Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES
page 20
page 21
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
B
C
G
A
E
F
D
B
C
G
A
E
F
D
Photo ofRG2DVMH30T6X
Residential GasManufactured Home Closed Combustion/Direct Vent Models
22/23
l Housing and Urban Developmentl Sealed Combustion Roof Jack Kit—Must order for new installationsl Flue Bafflel Heat Trapsl Vitraglas® Liningl Fully Automatic Controlsl 2" Non-CFC Foam Insulationl Water Connections—3⁄4" NPTl Protective Magnesium Anode Rodl T&P Relief Valvel Low Restriction Brass Drain Valvel Convertible Gas Control
30,00030,000
3040
RG2DVMH3OT6XRG2DVMH4OT6X
5259
579/16
571/41820
501/4501/2
119139
133/4133/4
33
NATURAL GAS AND LIQUID PROPANE GAS MODELS Recovery90°F Rise*
A
Floor toTop ofHeater
1st HourRating(Gal.)
0.630.62
EnergyFactor
3232
U.S.GPH
2727
Imp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floorto T&PConn.
E
Floor toGas
Conn.
221/2221/2
F
Floor toCold Water
Conn.
571/258
G
Floor toHot Water
Conn.
Approx.Shipping
Weight (lbs)
To order Natural Gas heaters change “X” to “N”. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
Optional Roof Jack Kits
Part Number12"
18" / 32"32" / 60" 48" / 90"
239-37022-01239-37022-02239-37022-03239-37022-04
A15"
331/2"321/2"- 621/2"
50"- 981/2"
BThrough The Roof
Clearance16"- 33"
331/2"- 66"371/2"- 74"
541/2"- 1091/2"
Includes: roof jack, hardware, air intake, instructions.
B
22.5° Max.
A11 5/8"Square
6 1/2"
7"
4"
5"
3"
9"
This water heater is of the closed combustion type (direct venting) for mobile home applications only, where all combustion air is supplied from the outdoors through the air intake and all combusted gas products are vented directly to the outside by means of the roof jack. No draft diverter (vent hood) is required for this water heater. The ETL listing of this water heater includes the field installation of the following components: roof jack, roof jack clamp, air intake, air intake seal, and heater tie down materials. These components for field installation are shipped with the heater in a separate box and must be installed according to instructions. No other components are approved for use with the water heater. The water heater must be installed in accordance with The Federal Mobile Home Construction and Safety Standard or in the absence of such standard, The Standard for Mobile Homes (ANSI/NFPA No. 601B-1977)
Manufactured Home Closed Combustion/Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES
page 22
page 23
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
B
K
C
G
A
H
E
F
D
B
K
C
G
A
H
E
F
D
Photo ofRG2MH30T6X
Residential GasManufactured Home Atmospheric Combustion Models
24/25
l Defender Safety System® featuring the patented Advanced ScreenLok® Technology flame arrestor design
- Resettable Thermal Switch - Maintenance-Free - Sight Window - Pedestal Basel Piezo Igniterl Housing and Urban Developmentl Roof Jack Kit—Must order for
new installationsl Vitraglas® Liningl Fully Automatic Controlsl Convertible Gas Controll 2" Non-CFC Foam Insulationl Water Connections—3⁄4" NPTl Heat Trapl Protective Magnesium Anode Rod
l 3"x4" “Snap Lock” Draft Diverterl Flue Bafflel Steel Tankl T&P Relief Valvel Low Restriction Brass Drain Valvel Design Certified by CSA International
(formerly AGA/CGA).
32,00034,000
3040
RG2MH30T6XRG2MH40T6X
5557
591/8593/8
1820
505/16
505/16
118135
1313
3 x 43 x 4
NATURAL GAS AND LIQUID PROPANE GAS MODELS Recovery90°F Rise*
A
Floor toFlue Conn.
1st HourRating(Gal.)
0.630.63
EnergyFactor
3437
U.S.GPH
2831
Imp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor toT&P
Conn.
E
Floor toCold Water
Conn.
221/2221/2
F
Floor toHot Water
Conn.
573/4573/4
G
Floor toHeater
Top
2022
K
Depth
567/8567/8
H
Floor toHeater
Top
Approx.Shipping
Weight (lbs)
To order Natural Gas heaters change “X” to “N”. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
Optional Roof Jack Kits
Part Number12"
18" / 32"32" / 60" 48" / 90"
239-37030-01239-37030-02239-37030-03239-37030-04
A15"
331/2"321/2"- 621/2"
50"- 981/2"
BThrough The Roof
Clearance16"- 33"
331/2"- 66"371/2"- 74"
541/2"- 1091/2"
Includes: roof jack, hardware, air intake, instructions.
B
C
G H
E
K
B
22.5° Max.
A11 5/8"Square
6 1/2"
7"
4"
5"
3"
9"
ANODE
AD
F
The water heater enclosure access door must be on the outside wall of the manufactured home (mobile home) only. Access to the water heater enclosure from the inside of the manufactured home (mobile home) is not permitted. The CSA International (formerly AGA/CGA) listing of this water heater includes the field installation of the following components: roof jack and heater tie down materials. These components for field installation are shipped in a separate box from the heater and must be installed according to instructions. No other components are approved for use with the water heater. The water heater must be installed in accordance with The Federal Manufactured Home Construction and Safety Standard Title 24 CRF, Part 3280.
Manufactured Home Atmospheric Combustion Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed77% Recovery EfficiencyDIMENSIONS IN INCHES
page 24
page 25
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
B
G
C
A
F
E
D
B
G
C
A
F
E
D
Photo ofURG1D50T6N
Residential GasUltra Low NOx Atmospheric Vent Damper Models
26/27
l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control - Intelligent Diagnostics - Separate Immersed Thermowelll Automatic Flue Damper
- 10 ft. Power Cord Included (120 VAC)l Eco-Defender Safety System® featuring the
patented advanced ScreenLok® Technology flame arrestor design
- Digital Thermal Sensor and Resettable Thermal Switch
- Maintenance-Free - Sight Window - Pedestal Basel Ultra Low NOx Burner with Primary
and Secondary Air Distribution Devicesl Hydrojet® Total Performance Systeml Vitraglas® Liningl 1" Non-CFC Foam Insulation
l Water Connections—3⁄4" NPT l Heat Trapsl Protective Magnesium Anode Rodl 3"x4" “Snap Lock” Draft Diverterl T&P Relief Valve l Low Restriction Brass Drain Valvel Design Certified by CSA International (formerly
AGA and CGA).l Complies with the Latest Ultra Low NOx
Requirement (10 ng/J NOx limit)
32,00040,00040,00040,000
30404050
URG1D30T6NURG1D40S6NURG1D40T6NURG1D50T6N
58747689
635413/16
639/16
633/8
16201820
497/841
501/8497/8
120151138164
113/4113/4113/4113/4
3 x 43 x 43 x 43 x 4
NATURAL GAS MODELS Recovery90°F Rise*
A
Floor toFlue
Conn.
1st HourRating(Gal.)
0.650.620.620.60
EnergyFactor
34434354
NatU.S.GPH
25363645
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor toT&P
Conn.
E
Floor toGas
Conn.
571/8491/8571/2577/8
F
Floor toWaterConn.
203/4243/4223/4243/4
G
Depth
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
Ultra Low NOx Atmospheric Vent Damper Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES
page 26
page 27
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
B
G
C
F
E
D
A
�
B
G
C
F
E
D
A
�
Photo ofURG250T6N
Residential GasUltra Low NOx Atmospheric Vent Models
28/29
l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Eco-Defender Safety System® featuring the
patented advanced ScreenLok® Technology flame arrestor design
- Digital Thermal Sensor and Resettable Thermal Switch
- Maintenance-Free - Sight Window - Pedestal Basel Ultra Low NOx Burner with Primary and
Secondary Air Distribution Devicesl Hydrojet® Total Performance Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connections—3⁄4" NPTl Heat Traps
l Protective Magnesium Anode Rodl 3"x4" “Snap Lock” Draft Diverterl Flue Bafflel Steel Tankl T&P Relief Valvel Low Restriction Brass Drain Valvel Design Certified by CSA International
(formerly AGA and CGA)l Complies with the Latest
Ultra Low NOx Requirement (10 ng/J NOx limit)
27,00032,00034,00040,00040,00034,00040,00040,00050,000
303040404050504850
URG130T6N•URG230T6N•URG140T6N•URG240T6N•URG240S6N•URG150T6N•URG250T6N•URG250L6NURG250S6N•
525870767482908893
591/8597/8603/4601/4515/8595/8603/16
515/8591/2
161818202220222422
493/4 / 563/8497/8 / 563/8511/2 / 591/250 / 565/841 / 471/450 / 563/8497/8 / 57
405/8497/8 / 572
112119130137149153160174169
113/4113/4113/4113/4113/4113/4113/4113/4113/4
3 x 43 x 43 x 43 x 43 x 43 x 43 x 43 x 4
4
NATURAL GAS MODELS Recovery90°F Rise*
A
Floor toFlue
Conn.
1st HourRating(Gal.)
0.630.640.620.620.620.600.620.600.60
EnergyFactor
293437434337434354
NatU.S.GPH
242831363631363645
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor toT&P
Conn.
E
Floor toGas
Conn.
571/257
591/8571/2491/858
585/16
493/8583/16
F
Floor toWaterConn.
191/2211/2211/2231/2251/2231/2251/2271/2251/2
G
Depth
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency.• Models feature optional top T&P location and must be specified when ordering. Energy Factor and First Hour Rating are based on the latest AHRI directory listings. (URG130T, URG140T, & URG150T available with top T&P location ONLY)
Ultra Low NOx Atmospheric Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES
page 28
page 29
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofURG250H6NModels URG250H6N & URG275H6N
BK
C
L
J
H
E F
A
D&G
M
B
C
K
A
J
E F
G
D
L
M
Model URG2100H6N
Residential GasUltra Low NOx Atmospheric Vent High Input Models
30/31
l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature
Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Eco-Defender Safety System®
featuring the patented advanced ScreenLok® Technology flame arrestor design
- Digital Thermal Sensor and Resettable Thermal Switch
- Maintenance-Free - Sight Window - Pedestal Basel Defender Combustion Chamber
(URG250H6N only)l Ultra Low NOx Burner with
Primary and Secondary Air Distribution Devices
l Hydrojet® Total Performance Systeml Vitraglas® Lining
l Side Connections—3/4" NPTl Non-CFC Foam Insulationl Water Connectionsl Heat Trapsl Protective Magnesium
Anode Rodl 4" (107mm) “Snap Lock”
Draft Diverter.l T&P Relief Valvel Low Restriction Brass
Drain Valvel Design Certified by CSA
International (formerly AGA and CGA).
l URG250H6N Complies with the Latest Ultra Low NOx Requirement (10 ng/J NOx limit) URG275H6N / URG2100H6N complies with (14 ng/J NOx limit)
55,00076,00085,000
4875100
URG250H6NURG275H6NURG2100H6N
100N/AN/A
605/16
641/8707/16
2226
281/4
497/8539/16
607/16
194286416
111/2151/8163/4
444
NATURAL GAS MODELS Recovery90°F Rise*
A
Floor to Flue Conn.
1st HourRating(Gal.)
0.60N/AN/A
EnergyFactor
598292
NatU.S.GPH
496877
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
133/8165/8183/4
F
Floor toSpace
HeatingReturn
497/8539/16
513/4
G
Floor toSpace
HeatingOutlet
563/8601/868
H
Floor toTop ofHeater
5713/16
611/8691/8
J
Floor toWaterConn.
257/16
297/16
311/2
K
Depth
111116
L
C/L ofWaterConn.
3/41
11/4
M
NPT
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
Ultra Low NOx Atmospheric Vent High Input Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedRecovery efficiency up to 80%DIMENSIONS IN INCHES
page 30
page 31
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
BH
C
J
A
G
E
D&M
F
L
BH
C
J
A
G
E
D&M
F
L
Photo ofURG2PV50H6N
Residential GasUltra Low NOx TTW® Power Vent Models
32/33
l ENERGY STAR® Qualified—Some modelsl Ultra Low NOx Burner with Primary and
Secondary Air Distribution Devicesl Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnosticsl Eco-Defender Safety System® featuring the
patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.)
- Digital Thermal Sensor and Resettable Thermal Switch
- Maintenance-Free - Sight Window - Pedestal Basel Separate Immersed Thermowelll Powerful Blower Motor
- 10 ft. Power Cord Included (120 VAC)l Horizontal and Vertical Ventingl Hydrojet® Total Performance Systeml Vitraglas® Lining
l Non-CFC Foam Insulationl Water Connectionsl Heat Trapsl Protective Magnesium Anode Rodl T&P Relief Valvel Low Restriction Brass Drain Valvel All Models Comply with the Latest
Ultra Low NOx Requirement (10 ng/J NOx limit) except URG2PV75H6N (14 ng/J NOx limit)
40,00040,00040,00040,00056,00076,000
405040504875
URG1PV40S6N URG1PV50S6NH URG2PV40T6NH URG2PV50T6NH URG2PV50H6N URG2PV75H6N
7286728699N/A
571/4581/4667/8667/8663/8691/4
202220222226
40405/8497/8497/8497/8517/8
144169151176192270
113/4113/4113/4113/4113/4113/4
2 or 32 or 32 or 32 or 33 or 43 or 4
NATURAL GAS MODELS Recovery90°F Rise*
A
Floor toVent
Conn.
1st HourRating(Gal.)
0.660.650.700.700.70N/A
EnergyFactor
434343436082
NatU.S.GPH
363636365068
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
471/8481/8565/8565/8565/8591/2
F
Floor toTop ofHeater
481/2491/258585861
G
Floor toWaterConn.
247/8267/8247/16
267/16
261/2301/4
H
Depth
88881111
J
C/L ofWaterConn.
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 10 year models, change suffix from “6” to “10”.* Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.H = ENERGY STAR® Qualified.
2" Vent Pipe
URG1PV40S6NURG1PV50S6NURG2PV40T6NURG2PV50T6N
3" Vent Pipe 3" Vent Pipe
URG2PV50H6NURG2PV75H6N
4" Vent Pipe
†50 ft.7 ft.45 ft.40 ft.35 ft.
123
Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows
†120 ft.15 ft.115 ft.110 ft.105 ft.
†50 ft.7 ft.
45 ft.40 ft.35 ft.
†180 ft.15 ft.
175 ft.170 ft.165 ft.
† For high altitude installations, consult the installation instructions.
Ultra Low NOx TTW® Power Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES
page 32
page 33
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofURG2PDV50H6N
K
N
A
JF
EL
B
D & M
C
H
K
N
A
JF
EL
B
D & M
C
H
Residential GasUltra Low NOx Power Direct Vent Models
34/35
l ENERGY STAR® Qualifiedl Ultra Low NOx Burner with Primary and
Secondary Air Distribution Devicesl Eco-Defender Safety System®
- Maintenance-Free - Sight Window - Pedestal Basel Closed Combustion Venting Systeml Bradford White ICON System™
- Enhanced Performance - Advanced Temperature
Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Cast Aluminum Air Intake Bootl Hydrojet® Total Performance Systeml Vitraglas® Liningl Powerful Blower Model
- 10 ft. Power Cord Included (120 VAC)l Optional Concentric Vent Kit
Terminationl Horizontal and Vertical Venting
l 2" Non-CFC Foam Insulationl Water Connections— 3⁄4" NPT l 3/4" NPT Side Connections—
(URG2PDV50H6N only)l Heat Trapsl Protective Magnesium Anode Rodl T&P Relief Valve
l Low Restriction Brass Drain Valvel Complies with the Latest Ultra Low NOx
Requirement (10 ng/J NOx limit)
40,00040,00050,000
405048
H URG2PDV40S6NH URG2PDV50S6NH URG2PDV50H6N
728692
591/2
601/2691/4
222422
423/8
43521/4
170196208
137/8137/8137/8
2 or 32 or 33 or 4
NATURAL GAS MODELS Recovery90°F Rise*
A
Floor toExhaustOutlet
1st HourRating(Gal.)
0.700.700.68
EnergyFactor
434364
NatU.S.GPH
363645
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor toT&P
Conn.
E
Floor toGas
Conn.
493/4603/8691/4
F
Floor toTop ofHeater
593/8503/4583/4
H
Floor toAir
Intake
515260
J
Floor toWaterConn.
303/4323/432
K
Depth
——
153/4
L
Floor toSpaceHeatingReturn
——
521/4
M
Floor toSpaceHeatingSupply
101/2111/291/4
N
C/L Distance
From Intaketo Exhaust
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 10 year model, change suffix “6” to “10”. * Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.H = ENERGY STAR® Qualified.
INTAKE/COMBUSTION
AIR
RAINCAP
VENTEXHAUST
A
Concentric Vent Kit Termination
2" Kit
P/N 239-44069-02 29 1/4
A (in.)
3" Kit
P/N 239-44069-01 36 1/4
A (in.)
2" Vent Pipe
URG2PDV40S6NURG2PDV50S6N
35 ft.35 ft.7 ft.30 ft.25 ft.20 ft.
123
Max. Intake LengthMax. Exhaust LengthMin. Vent LengthNumberof90° Elbows
3" Vent Pipe
URG2PDV40S6NURG2PDV50S6N URG2PDV50H6N
85 ft.85 ft.7 ft.80 ft.75 ft.70 ft.
60 ft.60 ft.7 ft.
55 ft.50 ft.45 ft.
4" Vent Pipe
URG2PDV50H6N
100 ft.100 ft.7 ft.
95 ft.90 ft.85 ft.
Subtract 5ft. for each additional 90º elbow.
Ultra Low NOx Power Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES
page 34
page 35
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
J
H
F
E
B K K
AA
C C
L
D&M
Flexible Vent Kit (Side View)Telescoping Solid Vent Kit (Side View) Photo ofURG2DV50H6N
Residential GasUltra Low NOx Direct Vent Models
36/37
l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Eco-Defender Safety System®
- Resettable Thermal Switch - Maintenance-Free - Sight Window - Pedestal Basel Ultra Low NOx Burner with Primary
and Secondary Air Distribution Devicesl Closed Combustionl Reinforced Sealsl Hydrojet® Total Performance Systeml Vitraglas® Liningl Cast Aluminum Air Intake Bootl Telescoping Solid Vent Kitsl Flexible Vent Kitl Side Connections—3/4" NPT l 2" Non-CFC Foam Insulation
l Water Connections—3/4" NPT l Heat Trapsl Protective Magnesium Anode Rodl T&P Relief Valve
l Low Restriction Brass Drain Valvel Design Certified by CSA International (formerly AGA
and CGA).l Complies with the Latest Ultra Low NOx
Requirement (10 ng/J NOx limit)
Available in Natural Gas only. For 10 year models, change suffix from “6” to “10”. * Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
URG2DV40S6N / URG2DV50S6N Solid Vent Kit: Part No. 239-51283-00. Weight: 17 lbs.URG2DV40S6N / URG2DV50S6N Flexible Vent Kit: Part No. 239-51284-00. Weight: 11 lbs.URG2DV50H6N Solid Vent Kit: Part No. 239-51286-00. Weight: 22 lbs.URG2DV50H6N Flexible Vent Kit: Part No. 239-51287-00. Weight: 13 lbs.Kits can be ordered and shipped with water heater, or ordered and shipped separately. For vent kit components and venting instructions, refer to Installation and Operation Manual.
URG2DV40S6N / URG2DV50S6N Optional Telescoping Solid Vent Kits: URG2DV50H6N Optional Telescoping Solid Vent Kits:Kit “A” Telescopes from 43⁄4" to 511⁄16" Part No. 239-41260-00 Kit “F” Telescopes from 43⁄4" to 511⁄16" Part No. 239-42516-00Kit “B” Telescopes from 61⁄2" to 93⁄16" Part No. 239-41331-00 Kit “G” Telescopes from 61⁄2" to 93⁄16" Part No. 239-42517-00Kit “C” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-41029-00 Kit “H” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-42514-00Kit “D” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-41424-00 Kit “I” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-42512-00
38,00038,00045,000
405048
URG2DV40S6NURG2DV50S6NURG2DV50H6N
738488
631/2 min.
721/2 min.
757/8 min.
222222
433/8521/4521/4
198221240
151515
334
556
NATURAL GAS MODELS Recovery90°F Rise*
A
Floor to C/L of Vent
1st HourRating(Gal.)
0.620.600.60
EnergyFactor
414146
NatU.S.GPH
343438
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
I.D. O.D.
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
501/4591/4591/4
F
Floor toTop ofHeater
8811
H
C/L ofWaterConn.
511/2601/2601/8
J
Floor toWaterConn.
311/8311/8305/8
K
Depth
——
153/4
L
Floor toSpace
Heating Inlet
——
521/4
M
Floor toSpace
Heating Onlet
Approx.Shipping
Weight (lbs)
Ultra Low NOx Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES
page 36
page 37
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofRTG-199HE-N
B A
C
D
OptionalIntake
Intake
J
L
M
K
5 /1 2" 5 /1 2"
G H
I
Exhaust
B A
C
D
OptionalIntake
Intake
J
L
M
K
5 /1 2" 5 /1 2"
G H
I
Exhaust
B A
C
D
OptionalIntake
Intake
J
L
M
K
5 /1 2" 5 /1 2"
G H
I
Exhaust
Residential GasInfiniti Tankless™ High Efficiency Models
38/39
l ENERGY STAR® Qualifiedl Featuring the SRT™ Scale Reduction Technology - Vertical Modulating Burner Design - Dual Fan Configuration - Internal Turbulators - Dual Heat Exchangerl Built-In Digital Controll Active Bypassl Cascading Kit (Optional)l Venting Flexibilityl Gas Connection Flexibility—1/2", 3/4", or 1"l Inlet Water Filterl Space Saving Installationl Built-In Freeze Protectionl Interior and Exterior Installation Capabilityl Complies with the Latest Ultra-Low NOx
Requirement (10 ng/J NOx limit)
19,900–199,000Indoor / Outdoor*H RTG-199HE-N 3 0.95 140º F0.5
VentConn.
Recovery90°F Rise*
GPM
4.2
InputBTU/Hr.Installation
ModelNumber
EF RatingNat.
MinimumWater Flow
GPM
MaximumTemperature
Setting
309/16H RTG-199HE-N 74
A
Height
1713/16
B
Width
107/16
C
Depth
53/16
D
Intake/Exhaust
Center Line
69/16
G
HotWaterOutlet
61/8
H
ColdWaterInlet
65/16
I
HotWaterOutlet
211/16
J
GasConn.
23/8
K
CondensateTee
25/8
L
CondensateTee
23/8
L
GasConn
ModelNumber
Approx.Shipping
Weight (lbs)
For Propane (LP) Models change suffix “N” to “X”. Requires an electrical power supply from a 120VAC 60Hz properly rated receptacle and must be properly grounded. Power supply cord provided. * Outdoor installation requires optional outdoor kitH = ENERGY STAR® Qualified.
2" Venting
Twin Pipe
9.5 ft.9.5 ft.19.0 ft.5.0 ft.2.5 ft.
1
Max. Allowable Exhaust Vent LengthMax. Allowable Intake Vent LengthCombined Max. Allowable VentElbow Equivalency 90ºElbow Equivalency 45ºNumber of 90° Elbows
3" Venting
Twin Pipe Concentric
31.0 ft.31.0 ft.62.0 ft.5.0 ft.2.5 ft.
5
23.0 ft.23.0 ft.46.0 ft.5.0 ft.2.5 ft.
4
Twin Pipe Concentric
63.0 ft.63.0 ft.126.0 ft.5.0 ft.2.5 ft.
7
43.0 ft.43.0 ft.83.0 ft.5.0 ft.2.5 ft.
7
4" Venting
Infiniti Tankless™ High Efficiency ModelsNATURAL GAS AND LIQUID PROPANE GAS MODELSDIMENSIONS IN INCHES
page 38
page 39
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofRTG-199ME-N
B A
C
J
L
M
K
G H
I
D
5 /1 2" 5 /1 2"
OptionalIntake
Intake Exhaust
Residential GasInfiniti Tankless™ Mid Efficiency Models
40/41
l Featuring the SRT™ Scale Reduction Technology
- Vertical Modulating Burner Design - Dual Fan Configuration - Internal Turbulators - Dual Heat Exchangerl Built-In Digital Controll Cascading Kit (Optional)l Gas Connection Flexibility—1/2", 3/4", or 1"l Inlet Water Filterl Space Saving Installationl Built-In Freeze Protectionl Interior and Exterior Installation Capabilityl Complies with the Latest Ultra-Low NOx
Requirement (10 ng/J NOx limit)
19,900–199,000Indoor / Outdoor*RTG-199ME-N 3 0.83 140º F0.5
VentConn.
Recovery90°F Rise*
GPM
3.7
InputBTU/Hr.Installation
ModelNumber
EF RatingNat.
MinimumWater Flow
GPM
MaximumTemperature
Setting
309/16RTG-199ME-N 67
A
Height
1713/16
B
Width
107/16
C
Depth
53/16
D
Intake/Exhaust
Center Line
69/16
G
HotWaterOutlet
61/8
H
ColdWaterInlet
65/16
I
HotWaterOutlet
211/16
J
GasConn.
23/8
K
CondensateTee
25/8
L
CondensateTee
23/8
L
GasConn
ModelNumber
Approx.Shipping
Weight (lbs)
For Propane (LP) Models change suffix “N” to “X”. Requires an electrical power supply from a 120VAC 60Hz properly rated receptacle and must be properly grounded. Power supply cord provided.* Outdoor installation requires optional outdoor kit
3" Venting
28.5 ft.28.5 ft.57.0 ft.5.0 ft.2.5 ft.
5
Max. Allowable Exhaust Vent LengthMax. Allowable Intake Vent LengthCombined Max. Allowable VentElbow Equivalency 90ºElbow Equivalency 45ºNumber of 90° Elbows
4" Venting
61.25 ft.61.25 ft.122.5 ft.5.0 ft.2.5 ft.
7
Infiniti Tankless™ Mid Efficiency ModelsNATURAL GAS AND LIQUID PROPANE GAS MODELSDIMENSIONS IN INCHES
page 40
page 41
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Residential ElectricEnergy Saver Water Heaters
42/43
All models are ETL listed. All water connections are 3⁄4" NPT true dielectric fittings (RE120L). All electrical connections are 3⁄4". All models are certified at 300 psi test pressure and 150 psi working pressure. All models come equipped with two installed heat traps (except Utility, Wall Hung models, and RE120L).Note: The Upright and Lowboy heaters will be wired single phase interlocking (non-simultaneous) 240 volt with 4500 watt elements, unless otherwise specified. Other wattages are available up to 6000 watts (208, 240, 277 and 480 volt). (Reference chart on following page for non-simultaneous and simultaneous limitations). 4500 watt/240 volt elements require a 25 amp or 30 amp circ uit breaker. For 120 volt (non-simultaneous), all models have a maximum wattage of 3000. (120 and 277 volt can only be wired single phase.)
Note: The Utility and Wall Hung Heaters will be wired for 120 volt with a 1500 watt element. The 1500 watt/120 volt element requires a 20 amp breaker. Other wattages are available. Maximum wattage for 6 and 12 gallon tall utility models is 3000W. Maximum wattage for 10, 12 and 15 gallon utility models is 6000W. Maximum wattage for the 6 gallon wall hung model is 3000W. Maximum wattage for 12, 20 and 30 gallon wall hung models is 6000W.
General
Incoloy Element Availability Chart
yesnonononononononono
120V
1500200025003000350040004500500055006000
Watts
yesyesyesyesyesyesyesyesyesyes
208V
yesyesyesyesyesyesyesyesyesyes
240V
noyesnoyesnoyesyesyesyesyes
277V
noyesnoyesnoyesyesyesyesyes
480V
VoltageWattage
Limitations forSimultaneous
Operation
1500W / 1500W2000W / 2000W2500W / 2500W3000W / 3000W3500W / 3500W4000W / 4000W4500W / 4500W5000W / 5000W5500W / 5500W6000W / 6000W
yesnonononononononono
120V
yesyesyesyesyesyesyesyesnono
208V
yesyesyesyesyesyesyesyesyesno
240V
yesyesyesyesnoyesyesyesnoyes
277V
yesyesyesyesnoyesyesyesnoyes
480V
VoltageWattage
Limitations forNon-Simultaneous
Operation
1500W / 1500W2000W / 2000W2500W / 2500W3000W / 3000W3500W / 3500W4000W / 4000W4500W / 4500W5000W / 5000W5500W / 5500W6000W / 6000W
WattageLimitations forSingle Element
Operation
1500W2000W2500W3000W3500W4000W4500W5000W5500W6000W
yesyesyesyesnononononono
120V
yesyesyesyesyesyesyesyesyesyes
208V
yesyesyesyesyesyesyesyesyesyes
240V
yesyesyesyesnoyesyesyes
yes**yes
277V
yesyesyesyesnoyesyesyes
yes**yes
480V
DesignatorVoltage
A120
E277
H480
J600
L*208
C208/240
DesignatorWatt
J1000
K1250
L1500
M2000
N2500
P3000
R3500
S3800
T4000
W4500
X5000
Y5500
Z6000
Phase 13
Single PhaseThree Phase
Operation NS
Non-simultaneousSimultaneous
Designator240V Wattage208V Wattage
J1000—
K1250—
L15001000
M20001500
N25002000
P3000—
R35002500
S3800—
T40003000
W45003500
X5000—
Y55004000
Z60004500
X**—
5000
Y**—
5500†
Z**—
6000†
EX: RE3340T6-1NCWW
EX: RE3340T6-1NCWW
EX: RE3340T6-1NCWW
EX: RE3340T6-1NCWW, will give 240V with 4500W/4500W. This same heater can also be energized at 208V with reduced wattage of 3500W/3500W.* Use “L” voltage designator if wiring 208V with 5000, 5500 or 6000 watt.† Available in non-simultaneous only.
EX: RE3340T6-1NCWW* Use “L” voltage designator if wiring 208V with 5000, 5500 or 6000 watt.
For 120V, 277V, 480V, and 600V operation
For 240V and 208V operation (Dual rated elements show a value for both 240V and 208V)
** Incoloy® element only.
page 42
page 43
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofRE2H50R10B
AC
D
B
EF
Residential ElectricAeroTherm™ Series Heat Pump Models
44/45
l ENERGY STAR® Qualifiedl The AeroTherm™ Series Control
Panel - User-Friendly, Easy-to-Read
Display - LED’s Clearly Indicate the Current
Operating Mode - Display Communicates Current
Status, Mode and Set Point, and Displays Error Messages when Applicable
l Operating Modes Offer Flexibility - Heat Pump (Only) Mode - Hybrid Mode - Electric (Only) Mode - Vacation Model Quiet Operationl Can Be Laid Down for Easier
Transportationl Easily Accessible Top Mounted
Washable Air Filter
l Operating Air Temperature Range of 35-120°F for the Heat Pump
l Backup Electric Heating Elementsl Direct Heat Transfer with
Immersed Elementsl 2" Non-CFC Foam Insulationl Water Connections—3/4" NPTl Protective Magnesium Alloy
Anode Rodl T&P Relief Valvel Low Restriction Brass Drain Valvel Design Certified to NSF/ANSI 372
(Lead Content).l Northern Climate Tier 3 Capablel Optional Ducting Kit
6994
5080
RE2H50R10BRE2H80R10B
591/8711/8
213/425
88
195235
463/4583/4
603/4731/2
ELECTRIC MODELS Recovery90°F Rise*
A
Floor toHeater Top
3.393.26
EnergyFactor
2121
NatU.S.GPH
1818
NatImp.GPH
1st HourDelivery Rating
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor to Water Conn.
D
Distance Between
Water Conn.
E
Floor toCondensate
Conn.
383/4503/8
F
Floor toT&P
Heater
Approx.Shipping
Weight (lbs)
* Based on 4500/4000W, Non-Simultaneous Operation. Optional Ducting Kit: Part No. GVK8HS. Kit installation also requires 8" insulated flexible ducting, ducting support hangers, and exterior wall vents for inlet & outlet. Additional clearances required for ducting, refer to ducting kit instructions.
PARTS INCLUDED
Upper Inlet Duct Adapter
Lower Inlet Duct Adapter
Inlet Duct Filter
Outlet Duct Adapter
Drilling Screws (6)
8” Hose Clamps (2)
Assembly Screws (8)
AeroTherm™ Series Heat Pump ModelsC.E.C. ListedDIMENSIONS IN INCHES
page 44
page 45
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofRE250S6
B
8"
C
A
D
B
8"
C
A
D
Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)
Residential ElectricUpright Models
46/47
l Fully Automatic Controlsl Direct Heat Transfer with Immersed Elementsl Hydrojet® Total Performance Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connections—3⁄4" NPT l Heat Traps l Protective Magnesium Anode Rodl Simultaneous and Non-Simultaneous
Operation Availablel Voltages Available—120V, 208V, 240V,
277V, 480Vl Single Phase or Three Phase Operation
Available—120V & 277V l T&P Relief Valvel Design Evaluated by ETL in Accordance
with Part 280.707(d) of HUD Mobile Home Construction and Safety Standards for Energy Efficiency
47555667675567
30404050504050
RE330S6RE340S6RE340T6RE350S6RE350T6RE240S6†RE250S6†
47477/8605/847
585/84847
20222024222022
100114125144138123143
473/4485/8613/8473/4593/8483/4473/4
ELECTRIC MODELS Recovery90°F Rise*
A
Floor toHeater Top
0.950.950.950.950.950.950.95
EnergyFactor
21212121212121
NatU.S.GPH
18181818181818
NatImp.GPH
1st HourRating(Gal.)
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor to Water Conn.
473/4485/8613/8473/4593/8483/4473/4
D
Floor toT&P
Conn.
Approx.Shipping
Weight (lbs)
† Models include supplied insulation blanket (2" thick). Dimensions in charts above do not include blanket thickness. For 10 year models, change suffix “6” to “10”.* Based on 4500W/4500W, Non-Simultaneous operation. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
Wattage Limitations for Simultaneous Operation
Voltage120V 208V 240V 277V 480V
Wattage Limitations for Non-Simultaneous Operation
Voltage120V 208V 240V 277V 480V
Recovery�GPH Temperature Rise ºF
60 80 90 100 120Wattage
yesnonononononononono
yesyesyesyesyesyesyesyesnono
yesyesyesyesyesyesyesyesyesno
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
s (GPH based on Non-Simultaneous operation, when Simultaneous operation the GPH will approximately double.)
Upright ModelsC.E.C. ListedDIMENSIONS IN INCHES
page 46
page 47
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofRE240L6
B
8"
Anode(RE250L only)
OptionalTop T&PLocation
C
A
D
B
8"
Anode(RE250L only)
OptionalTop T&PLocation
C
A
D
Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)
Residential ElectricLowboy Models
48/49
l Models above 20-Gallon Meet or Exceed Efficiency Requirements
l Fully Automatic Controlsl Low Restriction Brass Drain
Valvel Direct Heat Transfer with
Immersed Elementsl Hydrojet® Total Performance
Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connections—3⁄4" NPTl Heat Trapsl Protective Magnesium
Anode Rodl Simultaneous and Non-
Simultaneous Operation Available
l Voltages Available—120V, 208V, 240V, 277V, 480V
l Single Phase or Three Phase Operation Available—120V & 277V
l T&P Relief Valve— Side T&P is standard. Optional top T&P location is available
l Design Evaluated by ETL in Accordance with Part 280.707(d) of HUD Mobile Home Construction and Safety Standards for Energy Efficiency
—455558
19283847
RE120L6†RE230L6**RE240L6**RE250L6**
247/8297/8325/8335/8
18222426
65129153173
255/8303/4331/2343/4
ELECTRIC MODELS Recovery90°F Rise*
A
Floor toHeater Top
—0.950.950.95
EnergyFactor
21212121
NatU.S.GPH
18181818
NatImp.GPH
1st HourRating(Gal.)
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor to Water Conn.
191/8 / 247/8241/8 / 305/8241/8 / 335/8241/2 / 345/8
D
Floor toT&P
Conn.††
Approx.Shipping
Weight (lbs)
Wattage Limitations for Simultaneous Operation
Voltage120V 208V 240V 277V 480V
Wattage Limitations for Non-Simultaneous Operation
Voltage120V 208V 240V 277V 480V
Recovery�GPH Temperature Rise ºF
60 80 90 100 120Wattage
yesnonononononononono
yesyesyesyesyesyesyesyesnono
yesyesyesyesyesyesyesyesyesno
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
s (GPH based on Non-Simultaneous operation, when Simultaneous operation the GPH will approximately double.)
** Models include supplied insulation blanket (2” thick). Dimensions in charts above do not include blanket thickness.
For 10 year models, change suffix “6” to “10”.* Based on 4500W/4500W, Non-Simultaneous operation. All models available with optional top T&P location (plugged).† Exempt from ASHRAE 90.1b (current standard). Energy Factor and First Hour Rating are based on the
latest AHRI directory listings.†† All models feature side T&P location and must specify top T&P when ordering. “D” dimension listed as side/top.
Lowboy ModelsC.E.C. ListedDIMENSIONS IN INCHES
page 48
page 49
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofRE16UWV6
TOPVIEW
D
C
WALL
HOTOUTLET
COLDINLET
ELECTRICAL JUNCTION BOX
8"
FRONTVIEW
1213/16"D
HOT OUTLET3/4" CONN.
COLD INLET3/4" CONN.
HEATING ELEMENT & THERMOSTAT ACCESS
A A
E
3/4" RELIEF VALVE OPENING
SIDEVIEW
WALL
BB
BOTTOMVIEW
FRONT
Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)
Residential ElectricWall Hung Models
50/51
l Fully Automatic Controlsl Direct Heat Transfer With a Single
Immersed Elementl Vitraglas® Liningl 1" Non-CFC Foam Insulation
l Heavy Duty Wall Mounting Bracketl Water Connections—3/4" l Protective Magnesium Anode Rod
l Voltages Available—120V, 208V, 240V, 277V, 480V
l Single Phase Operation Onlyl T&P Relief Valve
61219
RE16WV6†RE112WV6RE120WV6
153/4163/8243/8
141818
375467
145/8185/8185/8
ELECTRIC MODELS Recovery90°F Rise*
A
Height
777
NatU.S.GPH
666
NatImp.GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Wall to Front
113/4123/4181/4
D
Height to Bracket
117/8121/221
E
Floor toT&P Heater
Approx.Shipping
Weight (lbs)
VoltageWattage Limitations 120V 208V 240V 277V 480V
RecoveryGPH Temperature Rise ºF
60 80 90 100 120Wattage
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W2000W2500W3000W3500W4000W4500W5000W5500W6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
† Maximum wattage at any voltage is 3000W. For 10 year models, change suffix “6” to “10”. Single element only.* Based on 1500W operation.
Wall Hung ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES
page 50
page 51
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofRE112U6
Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)
4" ALTERNATECOLD INLET(PLUGGED)6 &12 GAL.
ONLY
PLUG TYPEANODE6 &12
GAL. ONLY
ALTERNATE HOTOUTLET (PLUGGED)
6 &12 GAL. ONLY
8"
B
C D
F
E
G
A
10 & 15 Gallon Models
B
F
F
C
E
D
GA
6, 12 & 20 Gallon Models
Residential ElectricUtility Models
52/53
l Fully Automatic Controlsl Direct Heat Transfer with a Single Immersed Elementl Vitraglas® Liningl 1" Non-CFC Foam Insulationl Water Connections—3/4" NPTl Alternate Top Water Connectionsl Protective Magnesium Anode Rodl Voltages Available—120V, 208V, 240V, 277V, 480Vl Single Phase Operation Onlyl T&P Relief Valvel Design Evaluated by ETL in Accordance with Part
280.707(d) of HUD Mobile Home Construction and Safety Standards for Energy Efficiency
61012121519
RE16U6†RE110U6RE112U6RE112T6†RE115U6RE120U6
161/2171/2167/8273/4201/4243/4
141618141818
354453485865
101/815
101/4211/8173/4181/4
ELECTRIC MODELS Recovery90°F Rise*
A
Floor to Heater Top
777777
NatU.S.*GPH
666666
NatImp*GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor toHot Water
Conn.
101/814
101/4211/8163/4181/4
D
Floor toT&P
Conn.
31/8511/16
33
61/83
E
Floor toCold Water
Conn.
161/2911/16
161/2273/4101/8101/4
F
Floor toAnode Rod
161/212
167/8273/4
1211/16
243/4
G
Floor toElectrical
Access
Approx.Shipping
Weight (lbs)
VoltageWattage Limitations 120V 208V 240V 277V 480V
RecoveryGPH Temperature Rise ºF
60 80 90 100 120Wattage
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W2000W2500W3000W3500W4000W4500W5000W5500W6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
† Maximum wattage at any voltage is 3000W. For 10 year models, change suffix “6” to “10”. Single element only.* Based on 1500W operation.
Utility ModelsC.E.C. ListedDIMENSIONS IN INCHES
page 52
page 53
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofRE1-2U
B
A
C
B
A
C
Residential ElectricPowerful Compact® Model
54/55
l Compact Designl Fully Automatic Controll Direct Heat Transfer with Immersed Elementl Vitraglas® Liningl Non-CFC Insulationl Water Connections—3/4" NPTl Protective Magnesium Anode Rodl T&P Relief Valve OpeningOptional Features:l Wall Mounting Bracketl Aluminum Anode Rod
2RE1-2U6 121/4 97/8 13135/16
ELECTRIC MODELS Recovery90°F Rise*
A
Floor toHeater Top
7
NatU.S.GPH
6
NatImp.GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor to Water Conn.
Approx.Shipping
Weight (lbs)
Includes a 4ft. cord with 3 prong grounded plug (20 amp circuit required). For 10 year models, change suffix “6” to “10”. Single element only.* Based on 1500W operation. Only available as 120V / 1500W.
Copper Screw Type Immersion ElementSMALL FLANGEOF BRACKET
SMALL FLANGEOF BRACKET
Optional Wall Mounting Bracket
(2 brackets)Part Number
265-45018-00
Powerful Compact® ModelMeet or exceed ASHRAE 90.1b (current standard) CEC ListedDIMENSIONS IN INCHES
page 54
page 55
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
THERMOSTATIC FLOWCONTROLLED
TWIN HEATINGMODULE
THERMOSTATICTHREE PHASE
SINGLE POINT
Residential Electric Specialty ProductsInstantaneous Water Heaters
56/57
l On Demand Hot Water—No delayl Cut Energy Waste—Flow switch activates heater only on
demand (no stand-by heat loss)l Continuous Hot Water—No storage capacity to run out l No T&P Relief Valve Needed—Check local codesl Integral Flow Restrictor—Built-in to ensure proper
temperature risel 10 Year Warranty on Heater Body/Element Assemblyl Easy Installation – Mounts on Wall – No Sweat
Connectionsl Ni Chrome Heating Element —A unique, patented flow
path ensures optimum heat transfer and extended element life
l Reduces Calcificationl Space Saving Installation—Compact sizel Field Serviceable Element —1 year warranty
3.03.53.54.14.15.5
ES-3000-1-S-10ES-3500-1-S-10ES-3500-4-S-10ES-4100-2-S-10ES-4100-5-S-10ES-5500-4-S-10
120120240208277240
41°48°48°56°56°75°
10 AWG10 AWG14 AWG12 AWG14 AWG10 AWG
Single Point Single Phase ModelsDIMENSIONS IN INCHES
ELECTRIC
Temp.Rise °F0.5 GPMVoltage
25.029.014.619.714.822.9
AMPSkW
RatingModel
Number*Recommended
Wire Size
7.59.5
EFT-7500-4-S-10EFT-9500-4-S-10
240240
34°43°
8 AWG8 AWG
Thermostatic Single Phase ModelsDIMENSIONS IN INCHES
ELECTRIC
Temp.Rise °F
1.5 GPM
25°32°
Temp.Rise °F
2.0 GPM
51°65°
Temp.Rise °F
1.0 GPM
68°86°
Temp.Rise °F
0.75 GPM
——
Temp.Rise °F
0.5 GPMVoltage
32.040.0
AMPSkW
RatingModel
Number*Recommended
Wire Size
SpecificationsDimensions: 10.75" x 5.25" x 2.875"Weight: 3 lbs.Materials: Cover: ABS UL rated 94Vo. Glass Reinforced “Fortron®” Heater Body and Ni Chrome ElementColor: White • Element: Replaceable cartridge insert • Pipe-Fittings: 3/8" compression at top of unit
SpecificationsDimensions: 10.75" x 5.25" x 2.875"Weight: 3 lbs.Materials: Cover: ABS UL rated 94Vo. Glass Reinforced “Fortron®” Heater Body and Ni Chrome ElementColor: White • Standard temperature range 100°F-140°F. • Element: Replaceable cartridge insert. • Pipe-Fittings: 1/2" compression at bottom of unit.U.L. Listed: E86887(M)
*Additional voltages and wattages are available. For more information, please consult factory.
Single Point Single Phase ModelsDIMENSIONS IN INCHES
Thermostatic Single Phase ModelsDIMENSIONS IN INCHES
page 56
page 57
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
5.56.57.58.39.5
EFC-5500-4-S-10EFC-6500-4-S-10EFC-7500-4-S-10EFC-8300-2-S-10EFC-9500-4-S-10
240240240208240
25°30°34°38°43°
10 AWG10 AWG8 AWG8 AWG8 AWG
Flow Controlled Single Phase ModelsDIMENSIONS IN INCHES
ELECTRIC
Temp.Rise °F
1.5 GPM
18°22°25°29°32°
Temp.Rise °F
2.0 GPM
38°44°51°57°65°
Temp.Rise °F
1.0 GPM
50°59°68°76°86°
Temp.Rise °F
0.75 GPM
75°88°———
Temp.Rise °F
0.5 GPMVoltage
23.027.032.039.040.0
CurrentPer
PhasekW
RatingModel
Number*Recommended
Wire Size
SpecificationsDimensions: 10.75" x 5.25" x 2.875"Weight: 3 lbs.Materials: Cover: ABS UL rated 94Vo. Glass Reinforced “Fortron®” Heater Body and Ni Chrome ElementColor: White • Standard temperature range 100°F-140°F. • Element: Replaceable cartridge insert. • Pipe-Fittings: 1/2" compression at bottom of unit.
19.0EFT-19000-4-D-10 240 43° 10 AWG
Series Two Single Phase Thermostatic ModelsDIMENSIONS IN INCHES
ELECTRIC
Temp.Rise °F
3.0 GPM
52°
Temp.Rise °F
2.5 GPM
65°
Temp.Rise °F
2.0 GPM
87°
Temp.Rise °F
1.5 GPMVoltage
2x40 Amps
CurrentPer
PhasekW
RatingModel
Number*Recommended
Wire Size
SpecificationsDimensions: 10" x 9" x 3"Weight: 8 lbs.Materials: Cover: Enameled Steel. Glass Reinforced “UDEL®” Heater Body and Ni Chrome ElementColor: White • Element: Dual replaceable cartridge inserts • Pipe-Fittings: 3/4" NPT at bottom of unit.U.S. Patent No.’s: 4,762,980 and 4,960,976
*Additional voltages and wattages are available. For more information, please consult factory.
Residential Electric Specialty ProductsInstantaneous Water Heaters (continued)
58/59
Flow Controlled Single Phase ModelsDIMENSIONS IN INCHES
Series Two Single Phase Thermostatic ModelsDIMENSIONS IN INCHES
18.024.032.0
EFTR-18000-6-T-10EFTR-24000-6-T-10EFTR-32000-6-T-10
480 Y**480 Y**480 Y**
41°54°73°
6 AWG6 AWG8 AWG
Series Three-Three Phase Thermostatic ModelsDIMENSIONS IN INCHES
ELECTRIC
Meet or exceed ASHRAE 90.1b (current standard) CEC ListedRecovery Efficiency ranging up to 78% (M-I-75 and M-I-100 have an 80% recovery efficiency.)
Temp.Rise °F
3.0 GPM
35°47°62°
Temp.Rise °F
3.5 GPM
32°41°55°
Temp.Rise °F
4.0 GPM
25°34°45°
Temp.Rise °F
5.0 GPM
49°65°87°
Temp.Rise °F
2.5 GPM
61°82°—
Temp.Rise °F
2.0 GPM
82°——
Temp.Rise °F
1.5 GPMVoltage
21.7 Amps28.9 Amps38.5 Amps
CurrentPer
PhasekW
RatingModel
Number*Recommended
Wire Size
28.038.0
EFT-28000-4-T-10EFT-38000-4-F-10
240240
65°86°
8 AWG Per Module8 AWG Per Module
Series Three-Single Phase Thermostatic ModelsDIMENSIONS IN INCHES
ELECTRIC
Temp.Rise °F
3.0 GPM
47°65°
Temp.Rise °F
4.0 GPM
76°104°
Temp.Rise °F
2.5 GPM
96°130°
Temp.Rise °F
2.0 GPM
——
Temp.Rise °F
1.5 GPMVoltage
3x40 Amps4x40 Amps
CurrentPer
PhasekW
RatingModel
Number*Recommended
Wire Size
SpecificationsSingle Phase Model Dimensions:12.25" x 15.25" x 4.25"Weight: 12 lbs.Three Phase Model Dimensions:12.125" x 20.1875" x 4.125"Weight: 15 lbs.Materials: Cover: Enameled Steel. Glass Reinforced “UDEL® “ Heater Body and Ni Chrome ElementColor: White • Element: Triple replaceable cartridge inserts • Pipe-Fittings: 3/4" NPT at bottom of unit.U.S. Patent No.’s: 4,762,980 and 4,960,976
VoltageCode Voltage
Voltage Identification CodeFor All Models
123456
120208220240277480
This unit must have 3 independent electrical circuits using correctly valued wire and 3 circuit breakers.
Example: EFT-28000-4-T-10The 4 in the model number indicates 240 volt.
* Additional voltages and wattages are available. For more information, please consult factory.** Neutral leg required.
Series Three-Single Phase Thermostatic ModelsDIMENSIONS IN INCHES
Series Three-Three Phase Thermostatic ModelsDIMENSIONS IN INCHES
page 58
page 59
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
ANODES
A
C
BK
G
F
H
E J
D
Solar SensorWiringJunction Box
SolarThermistorWires,Gas ControlSensor
SolarThermistorWires
ANODES
A
C
BK
G
F
H
E J
D
Solar SensorWiringJunction Box
SolarThermistorWires,Gas ControlSensor
SolarThermistorWires
Photo ofS-DW2-504T6FBN
Residential SolarDouble-Wall Gas Backup Models
60/61
l Heat Exchanger—Double-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil
l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature
Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Defender Safety System® featuring
the patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Resettable Thermal Switch
- Maintenance-Free - Sight Window - Pedestal Basel Backup Low NOx Burnerl Sensor Wires for Solar Thermistor
Connectionsl Hydrojet® Total Performance Systeml Vitraglas® Lining
l 3/4" NPT Female Connections on Front for Supply and Return
l 2" Non-CFC Foam Insulationl Potable Water Connections—
3⁄4" NPT true dielectric fittingsl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve
(ASSE Approved)
65,00065,00076,000
456075
S-DW2-504T6FBNS-DW2-65T6FBNS-DW2-75S6BN
--
696982
591/463
623/8
222426
444
113/8113/8143/8
223264306
321/4321/4345/8
50531/252
NATURAL GAS MODELS A
Floorto FlueConn.
B
JacketDia.
GPHRecovery
90°F Rise*
1st HourDeliveryRating
InputBTU/Hr.
Gal.Cap.
ModelNumber
C
VentSize
D
Floorto T&PConn.
E
Floorto GasConn.
H
Floor toSolar Collector
Supply
101/8101/8121/2
J
Floor toSolar Collector
Return
5050
G
Floor toSpace Heating
Outlet
56591/259
F
Floorto Heater
Top
60631/4623/4
G
Floorto Water
Conn.
2628
303/8
K
Depth
Approx.Shipping
Weight (lbs)
Heat Exchanger Pressure Drop Curve
Flow Rate (GPM)
Pres
sure
Dro
p (P
SID
)
Hea
d Lo
ss (f
t. w
.c.)
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14
* Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stabilized Stainless Steel propane burner. For propane (LP) models change suffix “BN” to “SX”. LP GAS MODELS
InputBTU/Hr.
GPH Rec.90°F Rise
S-DW2-504T6FSX 61,000 65S-DW2-65T6FSX 63,000 67S-DW2-75S6SX 76,000 82
EcoStor™ Double-Wall Gas Backup Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES
page 60
page 61
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
A
C
BK
G
F
H
E J
D
Solar SensorWiringJunction Box
SolarThermistorWires,Gas ControlSensor
SolarThermistorWires
A
C
BK
G
F
H
E J
D
Solar SensorWiringJunction Box
SolarThermistorWires,Gas ControlSensor
SolarThermistorWires
Photo ofS-DW2-TW-65T6FBN
Residential SolarEcoStor2™ TTW® Power Vent Double-Wall Gas Backup Models
62/63
l Heat Exchanger—Double-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil
l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Defender Safety System® featuring the
patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Resettable Thermal Switch
- Maintenance-Free - Sight Window - Pedestal Basel Backup Low NOx Burnerl Sensor Wires for Solar Thermistor
Connectionsl Horizontal and Vertical Ventingl High Efficiency Blower
- 10 ft. Power Cord Included (120 VAC)
l Hydrojet® Total Performance Systeml Vitraglas® Lining l Supply and Return Connections—
3⁄4" NPTl 2" Non-CFC Foam Insulationl Potable Water Connections—3⁄4" NPT true
dielectric fittingsl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel S-DW2-TW-75 Is Not FVIR Compliantl Thermostatic Mixing Valve (ASSE Approved)
67,00070,00076,000
456070
S-DW2-TW-50T6FBNS-DW2-TW-65T6FBNS-DW2-TW-75T6BN
-727582
591/463
623/8
591/4222426
3 or 43 or 4
4
113/8113/8143/8
247281336
321/4321/4345/8
50531/252
NATURAL GAS MODELS A
Floorto FlueConn.
B
JacketDia.
GPHRecovery
90°F Rise*
1st HourDeliveryRating
InputBTU/Hr.
Gal.Cap.
ModelNumber
C
VentSize
D
Floorto T&PConn.
E
Floorto GasConn.
H
Floor toSolar Collector
Supply
101/8101/8121/2
J
Floor toSolar Collector
Return
5050
G
Floor toSpace Heating
Outlet
56591/259
F
Floorto Heater
Top
60631/4623/4
G
Floorto Water
Conn.
2628
303/8
K
Depth
Approx.Shipping
Weight (lbs)
Heat Exchanger Pressure Drop Curve
Flow Rate (GPM)
Pres
sure
Dro
p (P
SID
)
Hea
d Lo
ss (f
t. w
.c.)
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Subtract 5ft. for each additional 90° elbow.
** S-DW2-TW-75 Max. 3" vent length is 50ft.
3"Vent Pipe
4"Vent PipeS-DW2-TW-75T6BN
S-DW2-TW-65T6FBNS-DW2-TW-50T6FBN
60 ft.**7 ft.55 ft.50 ft.45 ft.
180 ft.15 ft.
175 ft.170 ft.165 ft.
Max. Equivalent LengthMin. Equivalent LengthNumber 1of 290° Elbows 3
* Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stabilized Stainless Steel propane burner. For propane (LP) models change suffix “BN” to “SX”.
LP GAS MODELSInput
BTU/Hr.GPH Rec.90°F Rise
S-DW2-TW-50T6FSX 60,000 65S-DW2-TW-65T6FSX 63,000 68S-DW2-TW-75T6SX 75,500 81
EcoStor2™ TTW® Power Vent Double-Wall Gas Backup ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
80% Recovery EfficiencyDIMENSIONS IN INCHES
page 62
page 63
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofS-2-65T6FBN
65 /75 Gallon Capacity 100 Gallon Capacity
K
H
K
A A
G G
F F
E EJ J
D D
H
B B
CC
Solar Thermistor Wiresand Gas Control SensorUnder Cover
AnodeAnodes
Hot WaterOutletCold WaterInlet
Hot WaterOutletCold WaterInletSolar Sensor
WiringJunction Box
Solar SensorWiringJunction Box
FromSolarCollector
Solar ThermistorWires and GasControl SensorUnder Cover
SolarThermistorWiresUnder Cover
SolarThermistorWiresUnder Cover
To SolarCollector
To SolarCollector
From SolarCollector
AnodeAnodes
Hot WaterOutletCold WaterInlet
Hot WaterOutletCold WaterInletSolar Sensor
WiringJunction Box
Solar SensorWiringJunction Box
Residential SolarEcoStor™ Open Loop Gas Backup Models
64/65
l Heat Exchanger—Double-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil
l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control
System - Intelligent Diagnostics - Separate Immersed Thermowelll Defender Safety System®
featuring the patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Resettable Thermal Switch
- Maintenance-Free - Sight Window - Pedestal Basel Backup Low NOx Burnerl Hydrojet® Total Performance
System
l Vitraglas® Lining l Supply and return
Connections—3⁄4" NPTl 2" Non-CFC Foam Insulationl Potable Water Connections—3⁄4"
NPT (65 gallon), 1" NPT (75 gallon) and 11⁄4" NPT (100 gallon) true dielectric fittings
l Protective Anode Rods—65 and 75 gallon models (1 Anode Rod), 100 gallon Model (2 Anode Rods)
l T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve
(ASSE Approved)
65,00076,00085,000
6575100
S-2-65T6FBNS-2-75S6BNS-2-100T6BN
-698292
63623/8
6311/16
591/42426
281/4
444
113/8141/8141/4
215250400
601/4593/4383/4
531/252
391/4
NATURAL GAS MODELS A
Floorto FlueConn.
B
JacketDia.
GPHRecovery
90°F Rise*
1st HourDeliveryRating
InputBTU/Hr.
Gal.Cap.
ModelNumber
C
VentSize
D
Floorto T&PConn.
E
Floorto GasConn.
H
Floor toSolar Collector
Supply
101/8121/2171/2
J
Floor toSolar Collector
Return
5050
G
Floor toSpace Heating
Outlet
591/259
651/2
F
Floorto Heater
Top
601/4593/4671/2
G
Floorto Water
Conn.
28303/8321/4
K
Depth
Approx.Shipping
Weight (lbs)
* Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stabilized Stainless Steel propane burner. For propane (LP) models change suffix “BN” to “SX”. LP GAS MODELS
InputBTU/Hr.
GPH Rec.90°F Rise
S-2-65T6FSX 63,000 67S-2-75S6SX 76,000 82S-2-100T6SX 88,000 95
EcoStor™ Open Loop Gas Backup Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES
page 64
page 65
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
K
B
A
G
F
H
E J
D
B
SolarThermistorWiresand GasControl SensorUnder Cover
Anode Hot WaterOutletCold WaterInlet
From SolarCollector
From SolarCollector
SolarSensorWiringJunctionBox
SolarThermistorWiresUnder Cover
To SolarCollectorK
B
A
G
F
H
E J
D
B
SolarThermistorWiresand GasControl SensorUnder Cover
Anode Hot WaterOutletCold WaterInlet
From SolarCollector
From SolarCollector
SolarSensorWiringJunctionBox
SolarThermistorWiresUnder Cover
To SolarCollector
Photo ofS-2-TW65T6FBN
Residential SolarEcoStor™ TTW® Power Vent Open Loop Gas Backup Models
66/67
l 3/4" NPT Solar Collector Supply and Return Connections (No Internal Heat Exchanger)
l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Defender Safety System® featuring the
patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Flammable Vapor Sensor
- Maintenance-Free - Sight Window - Pedestal Basel Backup Low NOx Burnerl Sensor Wires for Solar Thermistor
Connectionsl Horizontal and Vertical Ventingl High Efficiency Blower
- 10 ft. Power Cord Included (120 VAC)l Hydrojet® Total Performance System
l Vitraglas® Lining l Supply and Return Connections—3⁄4" NPTl 2" Non-CFC Foam Insulationl Potable Water Connections—
3⁄4" NPT true dielectric fittingsl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve (ASSE Approved)
70,00076,000
6575
S-2-TW65T6FBNS-2-TW75T6BN
-7582
63623/8
591/42426
33
113/8141/8
225260
321/4345/8
531/252
NATURAL GAS MODELS A
Floorto FlueConn.
B
JacketDia.
GPHRecovery
90°F Rise*
1st HourDeliveryRating
InputBTU/Hr.
Gal.Cap.
ModelNumber
C
VentSize
D
Floorto T&PConn.
E
Floorto GasConn.
H
Floor toSolar Collector
Supply
101/8121/2
J
Floor toSolar Collector
Return
5050
G
Floor toSpace Heating
Outlet
591/259
F
Floorto Heater
Top
601/4593/4
G
Floorto Water
Conn.
28303/8
K
Depth
Approx.Shipping
Weight (lbs)
* Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stabilized Stainless Steel propane burner. For propane (LP) models change suffix “BN” to “SX”. 120 V.A.C. required for power venting. 120 V.A.C. 60HZ 3.1 Amperes.
Subtract 5ft. for each additional 90° elbow.** S-2-TW-75 Max. 3" vent length is 50 ft. (15.24 m).
3"Vent Pipe
4"Vent PipeS-2-TW75T6BN
S-2-TW65T6FBN
60 ft.**7 ft.55 ft.50 ft.45 ft.
180 ft.15 ft.
175 ft.170 ft.165 ft.
Max. Equivalent LengthMin. Equivalent LengthNumber 1of 290° Elbows 3
LP GAS MODELSInput
BTU/Hr.GPH Rec.90°F Rise
S-2-TW65T6FSX 63,000 68S-2-TW75T6SX 75,500 81
EcoStor™ TTW® Power Vent Open Vent Gas Backup ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
80% Recovery EfficiencyDIMENSIONS IN INCHES
page 66
page 67
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
ANODES
A
B
C
K
G
F
H
E J
D
Solar SensorWiringJunction Box
SolarThermistorWires,Gas ControlSensor
SolarThermistorWires
ANODES
A
B
C
K
G
F
H
E J
D
Solar SensorWiringJunction Box
SolarThermistorWires,Gas ControlSensor
SolarThermistorWires
Photo ofS-DW4-U5036FRN
Residential SolarEcoStor2™ SC Ultra Low NOx Double-Wall Gas Backup Models
68/69
l Heat Exchanger—Double-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil
l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Eco-Defender Safety System® featuring the
patented advanced ScreenLok® Technology flame arrestor design - Digital Thermal Sensor
- Maintenance-Free - Sight Window - Pedestal Basel Backup Ultra Low NOx Burnerl Sensor Wires for Solar Thermistor
Connectionsl Hydrojet® Total Performance Systeml Vitraglas® Lining l Supply and Return Connections—3⁄4" NPTl 2" Non-CFC Foam Insulation
l Potable Water Connections—3⁄4" NPT true dielectric fittings
l Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Complies with the Latest Ultra-Low NOx
Requirements (10/ngts NOx limit)l Thermostatic Mixing Valve (ASSE Approved)
40,00055,000
4560
S-DW4-U5036FRNS-DW2-U65T6FRN
-4357
591/463
591/42224
3 4
115/8115/8
233272
321/4321/4
50531/2
NATURAL GAS MODELS A
Floorto FlueConn.
B
JacketDia.
GPHRecovery
90°F Rise*
1st HourDeliveryRating
InputBTU/Hr.
Gal.Cap.
ModelNumber
C
VentSize
D
Floorto T&PConn.
E
Floorto GasConn.
H
Floor toSolar Collector
Supply
101/8101/8
J
Floor toSolar Collector
Return
5050
G
Floor toSpace Heating
Outlet
561/4591/2
F
Floorto Heater
Top
60631/4
G
Floorto Water
Conn.
2628
K
Depth
Approx.Shipping
Weight (lbs)
Heat Exchanger Pressure Drop Curve
Flow Rate (GPM)
Pres
sure
Dro
p (P
SID
)
Hea
d Lo
ss (f
t. w
.c.)
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14
* Based on manufacturer’s rated recovery efficiency. Complies with the latest ultra-low NOx requirement (10 ng/J NOx limit).
EcoStor2™ Ultra Low NOx Double-Wall Gas Backup ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
80% Recovery EfficiencyDIMENSIONS IN INCHES
page 68
page 69
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofS-DC-DW2-55R6SW
CD
H
GF
E
A
B Solar Sensor Wiring Junction Box
Electric WiringJunction Box
SolarThermistorWiresandThermostat
SolarThermistorWiresandThermostat
CD
H
GF
E
A
B Solar Sensor Wiring Junction Box
Electric WiringJunction Box
SolarThermistorWiresandThermostat
SolarThermistorWiresandThermostat
Residential SolarEcoStor™ Dual Coil Heat Exchanger Backup Models
70/71
l Dual Coil Design—A single-wall heat exchanger is located in the upper portion of the tank. A double wall heat exchanger is located in the lower portion of the tank
l Applications—Dual heat exchangers located inside the tank may be connected to a variety of different heating systems
l Sensor Wires for Solar Thermistor Connections
l Hydrojet® Total Performance Systeml Vitraglas® Lining l Supply and Return Connections—1"
NPT upper coil, 3⁄4" NPT lower coil l 2" Non-CFC Foam Insulation
l Potable Water Connections—3⁄4" NPT true dielectric fittings extend water heater life and eases installation
l Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve
(ASSE Approved)
5570110
S-DC-DW2-55R6SWS-DC-DW2-70R6SWS-DC-DW2-110R6SW
591/4591/4621/2
2224
281/4
623/4623/466
5353
553/4
282313442
SOLAR MODELS C
Floor to Water Conn.
B
JacketDia.
A
Floor to Heater Top
Gal.Cap.
ModelNumber
D
Floor toT&P Conn.
371/2371/2391/4
F
Floor toUpper Coll.
Return
5656
573/4
E
Floor toUpper Coll.
Supply
53/853/853/8
H
Floor toLower Coll.
Return
271/2271/2271/2
G
Floor toLower Coll.
Supply
Approx.Shipping
Weight (lbs)
0.00
2.00
4.00
6.00
8.00
10.00
12.00
0.00
5.00
10.00
15.00
20.00
25.00
Single-wall (Upper Coil)
Double-wall (Lower Coil)
Heat Exchanger Pressure Drop Curve
Flow Rate (GPM)
Pres
sure
Dro
p (P
SI)
Hea
d Lo
ss (f
t. w
.c.)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
EcoStor™ Dual Coil Heat Exchanger Backup ModelsDIMENSIONS IN INCHES
page 70
page 71
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofS-SW2-60R6DS
CD
F
E
A
B
Solar SensorWiringJunction Box
Optional Outletfor Recirculation(S-SW2-60R& S-SW2-75R)
Solar ThermistorWires UpperHeating Elementwith Thermostat
Thermostat(controlslower element)
Solar ThermistorWires LowerHeating Element
CD
F
E
A
B
Solar SensorWiringJunction Box
Optional Outletfor Recirculation(S-SW2-60R& S-SW2-75R)
Solar ThermistorWires UpperHeating Elementwith Thermostat
Thermostat(controlslower element)
Solar ThermistorWires LowerHeating Element
Residential SolarEcoStor™ SC Single-Wall Electric Backup Models
72/73
l Heat Exchanger—Single-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil
l Supplied Sensor Wires for Solar Thermistor Connections
l Integrated Mixing Devicel Element Backup—Single or dual
4500W heating elementsl Hydrojet® Total Performance Systeml Vitraglas® Lining l 1" NPT Female Connections on Front
for Supply and Returnl Potable Water Connections—3/4" NPT
true dielectric fittings l 2" Non-CFC Foam Insulationl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valve
l Thermostatic Mixing Valve (ASSE Approved)
6075115
S-SW2-60R6DSS-SW2-75R6DSS-SW2-115R6DS
591/4591/4623/4
2224
281/4
631/4631/4663/4
5353
553/4
210236340
SOLAR MODELS C
Floor to Water Conn.
B
JacketDia.
A
Floor to Heater Top
Gal.Cap.
ModelNumber
D
Floor toT&P Conn.
291/2291/2291/2
E
Floor toSolar Coll.
Supply
73/873/873/8
F
Floor toSolar Coll.
Return
Approx.Shipping
Weight (lbs)
ModelNumber Single
ElementDual
Element
Electric Backup Water Heating Ratings
First Hour Supply (Gal.) StandbyHeat Loss
Rating(°F/Hr.)
S-SW2-60R6DSS-SW2-75R6DSS-SW2-115R6DS
465383
8497124
1.10.90.7
Heat Exchanger Pressure Drop Curve
Flow Rate (GPM)
Pres
sure
Dro
p (P
SID
)
Hea
d Lo
ss (f
t. w
.c.)
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14
For single element models change “D” to “S”.(Ex. S-SW2-60R6SS)
EcoStor™ Single-Wall Electric Backup ModelsDIMENSIONS IN INCHES
page 72
page 73
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofS-DW2-60R6DS
CD
F
E
A
Solar SensorWiringJunction Box
Optional Outletfor Recirculation(S-DW2-60R& S-DW2-75R)
Solar ThermistorWires UpperHeating Elementwith Thermostat
Thermostat(controlslower elementon dualelement models)
Solar ThermistorWires LowerHeating Element(on dualelement models)
B
CD
F
E
A
Solar SensorWiringJunction Box
Optional Outletfor Recirculation(S-DW2-60R& S-DW2-75R)
Solar ThermistorWires UpperHeating Elementwith Thermostat
Thermostat(controlslower elementon dualelement models)
Solar ThermistorWires LowerHeating Element(on dualelement models)
B
Residential SolarEcoStor 2™ Double-Wall Electric Backup Models
74/75
l Heat Exchanger—Double-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil
l Supplied Sensor Wires for Solar Thermistor Connections
l Element Backup—Single or dual 4500W heating elements - Optional 5500W
l Hydrojet® Total Performance Systeml Vitraglas® Lining l 3/4" NPT Female Connections on Front
for Supply and Returnl Potable Water Connections—
3/4" NPT true dielectric fittings l 2" Non-CFC Foam Insulationl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valve
l Thermostatic Mixing Valve (ASSE Approved)
6075115
S-DW2-60R6DSS-DW2-75R6DSS-DW2-115R6DS
591/4591/4623/4
2224
281/4
631/4631/4663/4
5353
553/4
217241345
SOLAR MODELS C
Floor to Water Conn.
B
JacketDia.
A
Floor to Heater Top
Gal.Cap.
ModelNumber
D
Floor toT&P Conn.
291/2291/2291/2
E
Floor toSolar Coll.
Supply
73/873/873/8
F
Floor toSolar Coll.
Return
Approx.Shipping
Weight (lbs)
ModelNumber Single
ElementDual
Element
Electric Backup Water Heating Ratings
First Hour Supply (Gal.) StandbyHeat Loss
Rating(°F/Hr.)
S-DW2-60R6DSS-DW2-75R6DSS-DW2-115R6DS
465383
8497124
1.10.90.7
For single element models change “D” to “S”.(Ex. S-DW2-60R6SS)
Heat Exchanger Pressure Drop Curve
Flow Rate (GPM)
Pres
sure
Dro
p (P
SID
)
Hea
d Lo
ss (f
t. w
.c.)
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14
EcoStor2™ Double-Wall Electric Backup ModelsDIMENSIONS IN INCHES
page 74
page 75
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
B
A
C
ED
F
4
1
3
2
8"8"
#1 - 3/4" Pump Suction#2 - 3/4" Cold Inlet#3 - 3/4" Collector Return#4 - 3/4" Hot Outlet
Photo of MS80R6SS
Residential SolarSolar Saver® Electric Backup Models
76/77
l Vitraglas® Liningl Hydrojet® Total Performance Systeml Equipped with a 4500 watt Element And Automatic
Thermostat—Where a backup system is desired. If storage only is desired do not connect the unit to the electrical service.
l Top of Tank Access for Wiring and Water Connectionsl Pre-Wired Sensor Leadl Thermal Feetl Water Connections—3/4" NPT true dielectric fittings l 2" Non-CFC foam insulationl Protective Magnesium Anode Rodl Consult Factory for Other Wattagesl T&P Relief Valvel Low Restriction Brass Drain Valve
6580119
MS65R6SSMS80R6SS†MS120R6SS†
5959
621/2
222428
6060
631/2
521/2521/256
168210310
SOLAR MODELS C
Floor to Water Conn.
B
JacketDia.
A
Floor to Heater Top
Gal.Cap.
ModelNumber
D
Floor toT&P Conn.
—38
381/4
E
Fl. to Alt.Coll. Return
Conn.
—77/877/8
F
Fl. to Alt.Coll. Supply
Conn.
Approx.Shipping
Weight (lbs)
NOTE: Suffix letter “S” denotes single element and surface mounted thermostat. If requirements are for storage only, do not use element connections. Second suffix letter “S” denotes Screw-Type Element. Meets California Energy Commission requirements.† Models offer additional pump suction and collector return connections.
Solar Saver® Electric Backup ModelsMeet or exceed ASHRAE 90.1b (current standard)DIMENSIONS IN INCHES
page 76
page 77
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofC-SW2-504T10FBN
K
C
AJ
H
E
F
D & G
B
PLUG TYPEANODE
K
C
AJ
H
E
F
D & G
B
PLUG TYPEANODE
Residential GasCombi1™ Single-Wall Atmospheric Models
78/79
l Defender Safety System® featuring the patented advanced ScreenLok® Technology flame arrestor design (50 gallon model only) - Resettable Thermal Switch
- Maintenance-Free - Sight Window - Pedestal BaseAll Combi1™ Models Feature:l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature
Control System - Intelligent Diagnostics - Separate Immersed
Thermowelll Heat Exchanger—Single-wall 11⁄2"
O.D. enamel coated (Vitraglas®) Steel Coil
l Provides Domestic Hot Water and Space Heating in One System
l Low Heat Exchanger Head Loss —Up to 10 GPM flow, with less than 0.80 ft. of Head Loss
l Vitraglas® Liningl Hydrojet® Total Performance
Systeml Water Connections – 3/4" NPT
true dielectric fittings l 1" Front NPT Supply and Return
Connectionsl 2" Non-CFC Foam Insulationl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass
Drain Valvel Thermostatic Mixing Valve
(ASSE Approved)
65,00076,000
4572
C-SW2-504T10FBNC-SW2-75T10BN 92
112124
535863
591/4
621/4
2226 583/4
6259
50513/4
236292 521/4
5652
151/4151/4151/4
NATURAL GAS MODELS A
Floor toFlue
Conn.
13137/8
E
Floor toGas
Conn.
311/2295/8
F
Floor toExchanger
Inlet
563/859
H
Floor toTop ofHeater
603/863
J
Floor toTop Water
Conn.
241/2303/8
K
Depth
50513/4
G
Floor toExchanger
Outlet
B
JacketDia. GPH
Recovery90°F Rise*
1st Hour**DeliveryRating
InputBTU/Hr.
7081
GPHRecovery
90°F Rise*Gal.Cap.
ModelNumber
C
Height toTop ofHeater
D
Height toGas
Conn.
153/4153/4161/2
G
SpaceHeatingReturn
D
Floor toT&P
Conn.
F
SpaceHeatingOutlet4
4
C
VentSize
Approx.Shipping
Weight (lbs)
Heat Exchanger Head Loss
GPMFeet of Head Loss
20.03
50.20
80.51
100.80
121.15
All propane models feature a Titanium Stabilized Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”.* Based on manufacturer’s rated recovery efficiency. CAEF is .55 and CAAFLUE % is 80.0.
Heat Exchanger Values*
Supply TemperatureReturn TemperatureDifferentialFlow RateNet Output
140°F120°F20°F
4.1 GPM35,500 BTU/Hr.
120°F100°F20°F
4.6 GPM39,500 BTU/Hr.
100°F80°F20°F
4.6 GPM39,500 BTU/Hr.
120°F100°F20°F
5.6 GPM47,500 BTU/Hr.
100°F80°F20°F
5.6 GPM47,500 BTU/Hr.
C-SW2-504TC-SW2-75T C-SW2-504T C-SW2-75T
* These values were obtained using 180°F stored tank temperature. Net Output is the space heating capacity based on normal piping and pickup allowance of 15%. Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change.
LP GAS MODELSInput
BTU/Hr.GPH Rec.90°F Rise
C-SW2-504T10FSX 61,000 66C-SW2-75T10SX 76,000 81
Combi1™ Atmospheric Vent Model Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES
page 78
page 79
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofC-SW2-TW50T10FBN
K B
C
A
J
H
E
F
D & GK B
C
A
J
H
E
F
D & G
Residential GasCombi1™ TTW® Single-Wall Power Vent Models
80/81
l Defender Safety System® featuring the patented advanced ScreenLok® Technology flame arrestor design (50 gallon model only) - Resettable Thermal Switch
- Maintenance-Free - Sight Window - Pedestal BaseAll Combi1™ TTW® Models Feature:l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Heat Exchanger—Single-wall 11⁄2" O.D. enamel
coated (Vitraglas®) steell Provides Domestic Hot Water and Space Heating
in One Systeml Low Heat Exchanger Head Loss—Up to 10 GPM
flow, with less than 0.80 ft. of Head Lossl Vitraglas® Lining
l Power Vented - 10 ft. Power Cord Included (120 VAC)
l Hydrojet® Total Performance Systeml Horizontal and Vertical Ventingl Water Connections—3/4" NPT true dielectric
fittings l 1" NPT Front Supply and Return Connectionsl 2" Non-CFC Foam Insulationl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction
Brass Drain Valvel Thermostatic
Mixing Valve (ASSE Approved)
67,00076,000
4572
C-SW2-TW50T10FBNC-SW2-TW75T10BN 92
112124
535863
657/8
683/8
2226 583/4
6259
501/8
53243313 521/4
5652
151/4151/4151/4
NATURAL GAS MODELS A
Floor toVent
Conn.
113/4
15
E
Floor toGas
Conn.
311/2
341/2
F
Floor toExchanger
Inlet
563/8
601/4
H
Floor toTop ofHeater
603/4
641/4
J
Floor toTop Water
Conn.
263/4
31
K
Depth
50
53
G
Floor toExchanger
Outlet
B
JacketDia. GPH
Recovery90°F Rise*
1st Hour**DeliveryRating
InputBTU/Hr.
Gal.Cap.
7282
GPHRecovery
90°F Rise*Model
Number
C
Height toTop ofHeater
D
Height toGas
Conn.
153/4153/4161/2
G
SpaceHeatingReturn
D
Floor toT&P
Conn.
F
SpaceHeatingOutlet3 or 4
3 or 4
C
VentSize
Approx.Shipping
Weight (lbs)
All propane models feature a Titanium Stabilized Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”.* Based on manufacturer’s rated recovery efficiency. 120 V.A.C Required for Power Venting / 120 V.A.C., 60HZ, 3.1 Amperes.
Heat ExchangerHead Loss
GPM
2581012
Ft. ofHd. Loss
0.030.200.510.801.15
3"Vent Pipe
4"Vent Pipe
C-SW2-TW50C-SW2-TW75
60 ft.** 7 ft.55 ft.50 ft.45 ft.
180 ft. 15 ft.175 ft.170 ft.165 ft.
Max. Equivalent LengthMin. Equivalent LengthNumber 1of 290° Elbows 3
Subtract 5ft. for each additional 90° elbow.** C-SW2-TW75 maximum 3" vent length is 50ft.
Heat Exchanger Values*
Supply TemperatureReturn TemperatureDifferentialFlow Rate (TW50)Net Output (TW50)Flow Rate (TW75)Net Output (TW75)
140°F120°F20°F
4.1 GPM35,000 BTU/Hr.
4.1 GPM35,000 BTU/Hr.
120°F100°F20°F
4.6 GPM39,500 BTU/Hr.
5.6 GPM47,500 BTU/Hr.
100°F80°F20°F
4.6 GPM39,500 BTU/Hr.
5.6 GPM47,500 BTU/Hr.
* These values were obtained using 180°F stored tank temperature. Net Output is the space heating capacity based on normal piping and pickup allowance of 15%. Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change.
LP GAS MODELSInput
BTU/Hr.GPH Rec.90°F Rise
C-SW2-TW50T10FSX 60,000 65C-SW2-TW75T10SX 75,500 81
Combi1™ TTW® Single-Wall Power Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES
page 80
page 81
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofC-DW2-504T10FBN
K
C
AJ
H
E
F
D & G
B
K
C
AJ
H
E
F
D & G
B
Residential GasCombi2™ Double-Wall Atmospheric Models
82/83
l Defender Safety System® featuring the patented advanced ScreenLok® Technology flame arrestor design (50 gallon model only) - Resettable Thermal Switch
- Maintenance-Free - Sight Window - Pedestal BaseAll Combi2™ Models Feature:l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Heat Exchanger—Double-wall 11⁄2" O.D. enamel
coated (Vitraglas®) steel coil ensures separation of potable water and heating fluid
l Provides Domestic Hot Water and Space Heating in One System
l Low Heat Exchanger Head Loss—Up to 10 GPM flow, with less than 3.75 ft. of Head Loss
l Vitraglas® Lining
l Hydrojet® Total Performance Systeml Water Connections—3/4" NPT true dielectric
fittings l 3/4" Front NPT Supply and Return Connectionsl 2" Non-CFC Foam Insulationl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve
(ASSE Approved)
65,00076,000
4572
C-DW2-504T10FBNC-DW2-75T10BN 92
112124
535863
59 1/4
621/4
2226 583/4
6259
50513/4
238302 521/4
5652
151/4151/4151/4
NATURAL GAS MODELS A
Floor toFlue
Conn.
13137/8
E
Floor toGas
Conn.
27 7/8
295/8
F
Floor toExchanger
Inlet
56 3/859
H
Floor toTop ofHeater
60 3/863
J
Floor toTop Water
Conn.
241/2303/8
K
Depth
50513/4
G
Floor toExchanger
Outlet
B
JacketDia. GPH
Recovery90°F Rise*
1st Hour**DeliveryRating
InputBTU/Hr.
7081
GPHRecovery
90°F Rise*Gal.Cap.
ModelNumber
C
Height toTop ofHeater
D
Height toGas
Conn.
153/4153/4161/2
G
SpaceHeatingReturn
D
Floor toT&P
Conn.
F
SpaceHeatingOutlet4
4
C
VentSize
Approx.Shipping
Weight (lbs)
Heat Exchanger Head Loss
GPMFeet of Head Loss
20.15
50.94
82.40
103.75
125.40
All propane models feature a Titanium Stabilized Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”.* Based on manufacturer’s rated recovery efficiency. CAEF is .55 and CAAFLUE % is 80.0.
Heat Exchanger Values*
Supply TemperatureReturn TemperatureDifferentialFlow RateNet Output
140°F120°F20°F
2.3 GPM20,000 BTU/Hr.
120°F100°F20°F
3.4 GPM29,000 BTU/Hr.
100°F80°F20°F
4.4 GPM38,000 BTU/Hr.
* These values were obtained using 180°F stored tank temperature. Net Output is the space heating capacity based on normal piping and pickup allowance of 15%. Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change.
LP GAS MODELSInput
BTU/Hr.GPH Rec.90°F Rise
C-DW2-504T10FSX 61,000 66C-DW2-75T10SX 76,000 81
Combi2™ Double-Wall Atmospheric Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES
page 82
page 83
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofC-DW2-TW50T10FBN
K B
C
A
J
H
E
F
D & G
K B
C
A
J
H
E
F
D & G
Residential GasCombi2™ TTW® Double-Wall Power Vent Models
84/85
l Defender Safety System® featuring the patented advanced ScreenLok® Technology flame arrestor design (50 gallon model only) - Resettable Thermal Switch
- Maintenance-Free - Sight Window - Pedestal BaseAll Combi2™ TTW® Models Feature:l Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowelll Heat Exchanger—Double-wall 11⁄2" O.D. enamel
coated (Vitraglas®) steel coil ensures separation of potable water and heating fluid
l Provides Domestic Hot Water and Hydronic Heating in One System
l Low Heat Exchanger Head Loss—Up to 10 GPM flow, with less than 3.75 ft. of Head Loss
l Vitraglas® Liningl Hydrojet® Total Performance System
l Power Vented - 10 ft. Power Cord Included (120 VAC)
l Horizontal and Vertical Ventingl Water Connections—3/4" NPT
true dielectric fittings l 3/4" Front Supply and Return Connectionsl 2" Non-CFC Foam Insulationl Two protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve (ASSE Approved)
67,00076,000
4572
C-DW2-TW50T10FBNC-DW2-TW75T10BN 92
112124
535863
657/8
683/82226 583/4
6259
501/8
53245315 521/4
5652
151/4151/4151/4
NATURAL GAS MODELS A
Floor toVent
Conn.
113/4
15
E
Floor toGas
Conn.
28
307/8
F
Floor toExchanger
Inlet
563/8
601/4
H
Floor toTop ofHeater
603/4
641/4
J
Floor toTop Water
Conn.
263/4
31
K
Depth
501/8
53
G
Floor toExchanger
Outlet
B
JacketDia. GPH
Recovery90°F Rise*
1st Hour**DeliveryRating
InputBTU/Hr.
Gal.Cap.
7282
GPHRecovery
90°F Rise*Model
Number
C
Height toTop ofHeater
D
Height toGas
Conn.
153/4153/4161/2
G
SpaceHeatingReturn
D
Floor toT&P
Conn.
F
SpaceHeatingOutlet3 or 4
3 or 4
C
VentSize
Approx.Shipping
Weight (lbs)
All propane models feature a Titanium Stabilized Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”.* Based on manufacturer’s rated recovery efficiency. 120 V.A.C Required for Power Venting / 120 V.A.C., 60HZ, 3.1 Amperes.
Heat ExchangerHead Loss
GPM
2581012
Ft. ofHd. Loss
0.150.942.403.755.40
3"Vent Pipe
4"Vent Pipe
C-DW2-TW50C-DW2-TW75
60 ft.** 7 ft.55 ft.50 ft.45 ft.
180 ft. 15 ft.175 ft.170 ft.165 ft.
Max. Equivalent LengthMin. Equivalent LengthNumber 1of 290° Elbows 3
Subtract 5ft. for each additional 90° elbow.** C-DW2-TW75 maximum 3" vent length is 50ft.
Heat Exchanger Values*
Supply TemperatureReturn TemperatureDifferentialFlow RateNet Output
140°F120°F20°F
2.3 GPM20,000 BTU/Hr.
120°F100°F20°F
3.4 GPM29,000 BTU/Hr.
100°F80°F20°F
4.4 GPM38,000 BTU/Hr.
* These values were obtained using 180°F stored tank temperature. Net Output is the space heating capacity based on normal piping and pickup allowance of 15%. Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change.
LP GAS MODELSInput
BTU/Hr.GPH Rec.90°F Rise
C-DW2-TW50T10FSX 60,000 65C-DW2-TW75T10SX 75,500 81
Combi2™ TTW® Double-Wall Power Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedRecovery Efficiency ranging up to 80% (Minimum)DIMENSIONS IN INCHES
page 84
page 85
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo of SW-2-65-L
SW-2-30-L
SW-2-40R-LSW-2-50R-LSW-2-65-LSW-2-80-LSW-2-120-L
DA F
EG
C
B
D DA
F
F
E EG G
C C
B
A
B
POTABLECONNECTIONS
ANODE RODS(TYPICAL)
(TYPICAL)ANODE RODS
(TYPICAL)
POTABLECONNECTIONS
(TYPICAL)
ResidentialPowerStor Series® Single-Wall Indirect Models
86/87
l Heat Exchanger—Single-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil
l Vitraglas® Liningl Hydrojet® Total Performance
Systeml Water Connections—3/4" NPT true
dielectric fittings (SW-2-120L has 1" NPT water connection)
l 1" NPT Connection for Boiler Supply And Return
l 2" Non-CFC Foam Insulationl Immersion Type Aquastat—
Accurate temperature controll Three Protective Aluminum
Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valve
l Limited Lifetime Tank and Heat Exchanger Warranty
l AHRI Certifiedl Standby Heat Loss Is Less than
1/2 °F per Hour (ASHRAE 90.1b Current Standard)
32,00030,00040,00040,00040,00050,00040,00040,00050,00040,00076,00085,000
3038486075116
SW-2-30-LSW-2-40R-LSW-2-50R-LSW-2-65-LSW-2-80-LSW-2-120-L
2222222224
281/4
335/8411/8461/4591/459
621/2
59 1/8483/858
59 3/850
603/459 5/8493/4581/2603/4633/46811/16
281/4343/8401/8531/8527/8553/4
343/8417/84760
593/4631/4
164185195225250370
271/2271/2271/2271/2271/2281/2
A
Floorto FlueConn.
C
Floor toT&P
Conn.
A
Floor toHeater
Top
B
JacketDia.
InputBTU/Hr.
GallonCapacity
ModelNumber
D
Floor toWaterConn.
53/853/853/853/853/863/8
E
Floor toExchanger
Outlet
F
Floor toExchanger
Inlet
111/2111/2111/2111/2111/2111/2
G
Floor to Aquastat
Approx.Shipping
Weight (lbs)
ModelNumber 140°F 115°F
DOE Water Heater Performance
SW-2-30-LSW-2-40R-LSW-2-50R-LSW-2-65-LSW-2-80-LSW-2-120-L
140°F 115°F
Maximum FirstHour Rating
(Gal.) @
279288297306321357
429438447456470507
140°F 115°F4.24.24.24.24.24.2
6.76.76.76.76.76.7
ContinuousDraw Rating
(Gal./Min.) @
Approximate BoilerOutput Needed
For Ratings(BTU/Hr.)
ApproximateBoiler OutputNeeded for
Ratings (BTU/Hr.)220,000220,000220,000220,000220,000220,000
55,00055,00055,00055,000
ModelNumber
AHRI Water Heater Ratings
SW-2-30-LSW-2-40R-LSW-2-50R-LSW-2-65-LSW-2-80-LSW-2-120-L
140°F 115°FFirst HourDelivery
255260265275295325
ContinuousDraw Rating
@ 135°F(Gal./Hr.)
Approximate BoilerOutput Needed
For Ratings(BTU/Hr.)
235235235235235235
StandbyHeat Loss
Rating(°F/Hr.)
1.21.10.90.70.60.4
HeatSource
Flow Rate(Gal./Min.)
13.713.713.713.713.713.7
HeatReq.Rate
(BTU/Hr.)157,000157,000157,000157,000157,000157,000
55,00055,00055,00055,000
Note: These certified ratings were obtained with a heat source output rate and flow rate as specified and a 180° F boiler water supply temperature. Other results will be obtained under different conditions.
Note: Based on 200° F boiler water temperature and 50°F potable water inlet temperature.
PowerStor Series® Single-Wall Indirect ModelsDIMENSIONS IN INCHES
page 86
page 87
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofDW-2-50-L
B
D A
F
E
C
G
POTABLE WATER FITTINGS - 3/4" NPTANODES
COLDWATERINLET
HOTWATERINLET
TEMPERATUREANDPRESSURERELIEF VALVE
FROM BOILERSUPPLY3/4" NPT
TO BOILERRETURN3/4" NPT
DRAIN COUPLING3/4" NPT
SURFACEMOUNTEDTHERMOSTAT
B
D A
F
E
C
G
POTABLE WATER FITTINGS - 3/4" NPTANODES
COLDWATERINLET
HOTWATERINLET
TEMPERATUREANDPRESSURERELIEF VALVE
FROM BOILERSUPPLY3/4" NPT
TO BOILERRETURN3/4" NPT
DRAIN COUPLING3/4" NPT
SURFACEMOUNTEDTHERMOSTAT
l Heat Exchanger—Double-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil
l Head Loss—Less than 5 ft. of Head Loss with flows up to 10 GPM
l Vitraglas® Liningl Hydrojet® Total Performance Systeml Water Connections—3/4" NPT true
dielectric fittingsl 2" Non-CFC Foam Insulationl Surface-Mount Thermostatl Two Protective Magnesium Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel Limited Lifetime Warranty on Tank
and Heat Exchangerl AHRI Certified
l Standard Heat Loss—Less than 1/2 °F per Hour (ASHRAE 90.1b Current Standard)
ResidentialPowerStor2™ Series® Double-Wall Indirect Models
88/89
41461/45959
38486475
DW-2-40-LDW-2-50-LDW-2-65-LDW-2-80-L
22222224
343/8401/8531/8527/8
417/8471/460
593/4
53/853/853/853/8
111/2111/2111/2111/2
195205235255
D
Floor to WaterConn.
E
Floor toBoilerReturn
271/2271/2271/2271/2
F
Floor toBoilerSupply
C
Floor to T&P
Conn.
B
JacketDia.
A
Floor to Heater
TopGallon
Capacity
ModelNumber
G
Floor toThermostat
Approx.Shipping
Weight (lbs)11/2 (F&R)
11/2 (F)2 (R)
11/2 (T&F)2 (R)
ModelNumber
AHRI Water Heater Ratings
DW-2-40-LDW-2-50-LDW-2-65-LDW-2-80-L
First HourDelivery
123133148158
ContinuousDraw Rating
@ 135°F(Gal./Hr.)
98989898
StandbyHeat Loss
Rating(°F/Hr.)
1.10.90.70.6
MinimumHeat Req.
Rate(BTU/Hr.)
65,00065,00065,00065,000
MinimumHeat SourceFlow Rate(Gal./Min.)
8.08.08.08.0
ModelNumber
DOE Water Heater Performance
DW-2-40-LDW-2-50-LDW-2-65-LDW-2-80-L
140°F 115°F
Maximum FirstHour Rating
(Gal.) @
808796106
122129138148
140°F 115°F
ContinuousDraw Rating
(Gal./Min.) @
Approximate BoilerOutput Needed
For Ratings(BTU/Hr.)
0.90.90.90.9
1.61.61.61.6
55,00055,00055,00055,000
Note: These certified ratings were obtained with a heat source output rate and flow rate as specified and a 180° F boiler water supply temperature. Other results will be obtained under different conditions.
Note: Based on 200° F boiler water temperature and 50°F potable water inlet temperature.
PowerStor2™ Series® Double-Wall Indirect ModelsDIMENSIONS IN INCHES
page 88
page 89
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo of RTV-40-L
EF
H
CD A
G
OUTLET
T&P
B
E L
K H
17"*
C
F
GG 413/4"*
D
A
B
RTV-40-L RTV-52-L RTV-75-L
RTV-120-L*Floor to Top Spare 3/4” NPT
Tank Connection is 413⁄4”Floor to Bottom Spare 3/4” NPT
Tank Connection is 17”
1 2
1
2
ResidentialPowerStor Series® SS Stainless Steel Single-Wall Indirect Models
90/91
l Stainless Steel Heat Exchanger—Single-wall 1" O.D. stainless steel coil
l Stainless Steel Tank and Heat Exchanger—Made from Chromium Molybdenum - Titanium Ferritic 444 Stainless Steel Alloy
l Immersed Adjustable Honeywell Aquastat—Fast acting immersion aquastat for automatic temperature control
l Supply and Return Connections—3⁄4" NPT female connections are located on the front for both the Boiler Supply and Boiler Return (1" NPT on RTV-119)
l 2" Non-CFC Foam Insulation
l Potable Water Connections—3/4" NPT dielectric fittings extend water heater life and eases installation (11⁄4"w NPT on RTV-119)
l T&P Relief Valvel Low Restriction Brass Drain Valvel AHRI Certified
242424
301/4
351/4455/8637/8605/8
RTV-40-LRTV-52-LRTV-75-LRTV-120-L
555
111/4
91/291/291/2177/8
245/8283/8281/4451/2
8393117315
363/4463/8641/8641/8481/2
G
Floor toExchanger
Inlet
———
423/4
K
Floor toSpare 3/4" HotWater Conn.
———
177/8
L
Floor toSpare 3/4" Cold
Water Conn.
F
Floor toExchanger
Outlet
E
Floor toCold Water
Conn.
351/2457/8641/861
C
Floor toT&P
Conn.
B
JacketDia.
A
Floor toHeater
Top
405275119
Gal.Cap.
ModelNumber
F
Floor toWaterConn.
351/2457/8641/8491/2
D
Floor toHot Water
Conn.
19191936
H
Floor toAquastat
Approx.ShippingWeight
Notes:1) Inlet water temperature based on 50°F.2) RTV-119 supplied with 2 extra plugged tappings (see manual). Height to top spare plug is 413⁄4". Height to bottom spare plug is 17".3) RTV-119 equipped with steel casing.All potable water connections are 3/4” NPT (11⁄4" on RTV-119).3⁄4" Aquastat tapping.3⁄4" T&P valve tapping.
158200225360
RTV-40-LRTV-52-LRTV-75-LRTV-120-L
AHRI Water Heater Ratings
First HourDelivery
133165165280
ContinuousDraw
@ 135°F(Gal./Hr.)
0.90.70.50.6
StandbyHeat Loss
Rating(°F/Hr.)
88,000113,000113,000195,000
Min. HeatRequired
Rate(BTU/Hr.)
8.08.08.011.0
Min. HeatSource
Flow Rate(Gal./Min.)
ModelNumber
Note: These certified ratings were obtained with a heat output rate and flow rate as specified and a 180°F boiler water supply temperature. Other results will be obtained under different conditions.
PowerStor Series® SS Stainless Steel Single-Wall Indirect ModelsDIMENSIONS IN INCHES
page 90
page 91
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofAST-50-6
TOP CONNECTIONS
DRAIN/BOILER RETURN
T&P(NOTPROVIDED)
BOILERSUPPLY
OUTLET
B
A C
D
ETOP CONNECTIONS
DRAIN/BOILER RETURN
T&P(NOTPROVIDED)
BOILERSUPPLY
OUTLET
B
A C
D
E
ResidentialStorage Tank Models
92/93
l Vitraglas® Liningl Hydrojet® Total Performance Systeml Water Connections—3/4" NPT true dielectric fittings
(AST-120 has 1" NPT Connections) l 2" Non-CFC Foam Insulationl Fully Automatic Controlsl Protective Magnesium Anode Rodl Boiler Return Is 3/4"l Thermal Feetl T&P Relief Valve Openingl Brass Drain/Return Valve (3/4")
32,00030,00040,00040,00040,00050,00040,00040,00050,00040,00076,00085,000
405080119
AST-40-6AST-50-6AST-80-6AST-120-6
467/8465/16
587/8627/8
202224
281/4
59 1/8483/858
59 3/850
603/459 5/8493/4581/2603/4633/46811/16
477/8475/16
597/8637/8
31/16
31/16
31/16
31/16
103130183305
A
Floorto FlueConn.
C
Floor to Top Water Conn.
B
JacketDia.
A
Floor toHeater Top Input
BTU/Hr.
GallonCapacity
ModelNumber
D
Floor to Drain/Boiler Return
3/43/43/41
E
Outlet3/43/43/41
F
Heat SourceSupply
3/43/43/43/4
G
Heat SourceReturn
Approx.ShippingWeight (lbs)
Note: Circulator pump and temperature pressure relief valve are NOT included. We recommend you use a stainless steel or low lead circulator pump and relief valve of your choice when installing these storage tanks.
Storage Tank ModelsDIMENSIONS IN INCHES
page 92
page 93
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
The Bradford White MAGNUM Series® 94/95
If you’re selecting the water heating equipment for an apartment complex, restaurant, laundromat, hotel, school, manufacturing plant or any other business with a constant high demand for hot water, the Bradford White Magnum Series of commercial water heaters can fill all your requirements. Bradford White offers an extensive and comprehensive selection of water heating products for commercial applications. Our commercial and industrial models, known as the MAGNUM Series, include gas and electric light-duty versions, a full complement of high input Energy Saver units, Ultra High Efficiency unit (eF Seriesi), instantaneous models, booster units and storage tanks. Each and every one is designed and built to the most exacting quality specifications for durability, energy-efficiency and top performance.
Big Solution for Big DemandsBradford White commercial water heaters provide durability, energy efficiency, and exceptional performance you can rely on.
RightSpec® commercial sizing and specifying guide offers many unique features and upgrades. You’ll find it easy to use with complete specifications on the entire Residential and Magnum series line of commercial water heaters. The program enables you to determine the correct commercial model for any application including restaurants, apartment complexes and laundromats.
This interactive program includes a comprehensive cross reference guide that makes replacing any commercial or residential water heater with a Bradford White model quick and easy. You simply enter the model you wish to replace and the software will provide a Bradford White solution.
Scan the QR code to download the RightSpec® Cross-Reference Guide or any of our other FREE Apps!iPad/iPhone & Android Compatible
Visit Bradford White’s Interactive sizing and cross reference program at:
www.bradfordwhite.com
Also available as an APP!
RightSpec® - Interactive Sizing and Cross Reference
With RightSpec®, available on the web, you’ll have the sizing solution you need in a fraction of the time it took before.
page 94
page 95
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofLG2100H853N
LG155H803N LG2100H853NLG250H653N / LG275H763N
Commercial GasLight Duty Atmospheric Vent High Input Models
96/97
l Bradford White ICON System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell
l Defender Safety System® featuring the patented advanced ScreenLok® Technology flame arrestor design (LG250H653N model only) - Resettable Thermal Switch
- Maintenance-Free - Sight Window - Pedestal Basel Hydrojet 2™ Total
Performance System
l Vitraglas® Liningl Side Connections—3/4"
(19mm) NPT l Non-CFC Foam Insulationl Water Connectionsl Hand Hole Cleanoutl Protective Magnesium
Anode Rodl 4" (107mm) “Snap Lock”
Draft Diverterl T&P Relief Valvel Low Restriction Brass
Drain Valvel Thermostatic Mixing
Valve (ASSE Approved)(LG155H803N only)
65,00080,00076,00085,000
485575100
LG250H653NLG155H803NLG275H763NLG2100H853N
110N/AN/AN/A
60591/2625/869
222224
281/4
4915/16
497/8517/8595/16
193207263424
131413/16
15157/16
4444
NATURAL GAS MODELS Recovery100°F Rise*
A
Floor to Flue Conn.
1st HourRating(Gal.)
0.60N/AN/AN/A
EnergyFactor
63787482
NatU.S.GPH
53656269
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
565/85515/16
59651/2
F
Floor toTop ofHeater
1181116
H
C/L ofWaterConn.
577/8577/8607/16
6615/16
J
Floor toWaterConn.
26257/8271/4311/2
K
Depth
131/2157/16
165/81711/16
L
Floor toSpace
Heating Inlet
4915/16
497/8517/8505/8
M
Floor toSpace
Heating Outlet3/43/41
11/4
N
NPT
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”.For 5 year models, change suffix “3” to “5”. *Based on manufacturer’s rated recovery efficiency. LG2100H853N model features hand hole cleanout.Energy Factor and First Hour Rating are based on the latest AHRI directory listings.NSF kits available. LG250H653X
LG155H803XLG275H763XLG2100H853X
LP GAS MODELS InputBTU/Hr.
61,00078,00076,00088,000
Recovery100°F Rise*
59767485
LPU.S.GPH
49636271
LPImp.GPH
ModelNumber
Light Duty Atmospheric Vent High Input ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES
page 96
page 97
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
C
A
G
F
E J
B
D & K
H
8"
Photo ofLC2PV50H763N
C
A
G
F
E J
B
D & K
H
8"
Commercial GasLight Duty High Efficiency eF Series® Power Vent Models 90%+ Thermal Efficiency
98/99
l Vertical, Dual-pass Heat Exchanger System
l Vitraglas® Protection—On both primary and secondary heat exchanger
l Self-priming Condensate Teel Power Ventl Horizontal and Vertical Ventingl Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics
l Hydrojet® Total Performance Systeml Vitraglas® Liningl 2" Non-CFC Foam Insulationl Pedestal Basel Water Connections—3/4" NPTl 3/4" NPT Side Connections
l Heat Trapsl Two Protective Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valve
76,00050LC2PV50H763N 671/4 24 461/2 225135/82
Recovery90°F Rise*
Floor to Vent Conn.
83
U.S.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
Jacket Dia.
VentSize
Floor to T&P
Conn.
Floor toGas
Conn.
561/4
Floor toTop ofHeater
571/2
Floor toWaterConn.
273/8Depth
155/8
Floor toSpace
Heating Inlet
461/2
Floor toSpace
Heating Outlet
Approx.Shipping
Weight (lbs)
NATURAL GAS AND LIQUID PROPANEGAS MODELS
A B C D E F G H J K
2"Vent Pipe
3"Vent Pipe
4"Vent PipeLC2PV50H763N
†50 ft.7 ft.45 ft.40 ft.35 ft.
†120 ft.15 ft.115 ft.110 ft.105 ft.
†180 ft.15 ft.175 ft.170 ft.165 ft.
123
Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows
Subtract 5ft. for each additional 90° elbow.† For high altitude installations, consult the installation instructions.
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.* Based on 90.5% Thermal Efficiency.
Light Duty High Efficiency eF Series® Power Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES
page 98
page 99
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofLG2PV50H653N
B
H
K
C
J
F
E L
A
D&M
B
H
K
C
J
F
E L
A
D&M
Commercial GasLight Duty TTW® Power Vent Models
100/101
l Bradford White ICON System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell
l Powerful Blower Motor - 10 ft. Power Cord Included (120 VAC)
l Horizontal and Vertical Ventingl Defender Safety System® featuring the
patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Flammable Vapor Sensor - Maintenance-Free - Sight Window - Pedestal Base
l Hydrojet® Total Performance Systeml Vitraglas® Liningl Non-CFC Foam Insulation
l Water Connections—3/4" NPT l 3/4" NPT Side Connectionsl Heat Trapsl Protective Magnesium Rodl T&P Relief Valvel Low Restriction Brass Drain Valvel Thermostatic Mixing Valve (ASSE
Approved) (LG1PV55)
65,00078,00076,000
485575
LG2PV50H653NLG1PV55H783NLG2PV75H763N
112N/AN/A
661/8643/16
697/16
222226
501/84715/16
511/2
186253252
113/4111/2131/2
3 or 43 or 43 or 4
NATURAL GAS MODELS Recovery100°F Rise*
A
Floor to Flue Conn.
1st HourRating(Gal.)
0.70N/AN/A
EnergyFactor
637674
NatU.S.GPH
526362
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
563/8545/8591/2
F
Floor toTop ofHeater
11811
H
C/L ofWaterConn.
573/456
603/4
J
Floor toWaterConn.
263/4261/2301/4
K
Depth
131/2133/8133/8
L
Floor toSpace
Heating Inlet
501/84715/16
511/2
M
Floor toSpace
Heating Onlet
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 5 year models, change suffix from “3” to “5”.* Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC 60HZ 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
3" Vent Pipe
LG2PV50H653NLG1PV55H753NLG2PV75H753N
4" Vent Pipe
†50 ft.7 ft.45 ft.40 ft.35 ft.
123
Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows
†180 ft.15 ft.175 ft.170 ft.165 ft.
Subtract 5ft. for each additional 90° elbow† For high altitude installations, consult the installation instructions.
LG2PV50H653XLG1PV55H783XLG2PV75H763X
LP GAS MODELS Recovery100°F Rise*
InputBTU/Hr.
567673
58,00078,00075,500
LPU.S.GPH
476361
LPImp.GPH
ModelNumber
Light Duty TTW® Power Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES
page 100
page 101
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofLG2PDV50H603N
K
C
J F
EL
B
D & M
A H
K
C
J F
EL
B
D & M
A H
Commercial GasLight Duty Power Direct Vent Models
102/103
l Bradford White ICON System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell
l Defender Safety System® - Flammable Vapor Sensor - Maintenance-Free - Sight Window - Pedestal Base
l Powerful Blower Model - 10 ft. Power Cord Included (120 VAC)
l Closed Combustion Venting System
l Cast Aluminum Air Intake Bootl Horizontal and Vertical Venting
l Optional Concentric Vent Kit Termination
l Hydrojet® Total Performance System
l Vitraglas® Liningl 2" Non-CFC Foam Insulationl Water Connections—
3⁄4" NPTl Side Connections—
3/4" NPT l Heat Trapsl Protective Magnesium
Anode Rodl T&P Relief Valvel Low Restriction Brass
Drain Valve
60,00080,000
4875
LG2PDV50H603NLG2PDV75H803N
105—
6972
2226
521/4541/4
205392
135/8161/4
3 or 43 or 4
NATURAL GAS MODELS Recovery100°F Rise*
A
Floor toExhaustOutlet
1st HourRating(Gal.)
0.68—
EnergyFactor
5877
NatU.S.GPH
4864
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
583/4623/4
F
Floor toTop ofHeat
67703/8
H
Floor toAir
Intake
60633/4
J
Floor toWaterConn.
305/836
K
Depth
153/419
L
Floor toSpace Heating
Return
521/4541/4
M
Floor toSpace Heating
Supply
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 5 year models change suffix from “3” to “5”. * Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
INTAKE/COMBUSTION
AIR
RAINCAP
VENTEXHAUST
A 3" Vent Pipe
LG2PDV50H603NLG2PDV75H803N
4" Vent Pipe
60 ft.60 ft.7 ft.55 ft.50 ft.45 ft.
123
Max. Intake LengthMax. Exhaust LengthMin. Vent LengthNumberof90° Elbows
100 ft.100 ft.7 ft.95 ft.90 ft.85 ft.
Subtract 5ft. for each additional 90° elbow.
Concentric Vent Kit Termination
3" Kit
P/N 239-44069-01 291/4
A (in.)
LG2PDV50H603XLG2PDV75H803X
LP GAS MODELS InputBTU/Hr.
Recovery100°F Rise*
5876
60,00078,000
LPU.S.GPH
4863
LPImp.GPH
ModelNumber
Light Duty Power Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES
page 102
page 103
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofLG2DV50H503N
J
H
F
E L
B
D&MK
C C
A A
K
Flexible Vent Kit (Side View)Telescoping Solid Vent Kit (Side View)
Commercial GasLight Duty Direct Vent Models
104/105
l Bradford White ICON System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell
l Defender Safety System® - Resettable Thermal Switch - Maintenance-Free - Sight Window - Pedestal Base
l Closed Combustionl Reinforced Sealsl Hydrojet® Total Performance Systeml Vitraglas® Liningl Cast Aluminum Air Intake Bootl Telescoping Solid Vent Kitsl Flexible Vent Kitl Side Connections—3/4" NPT l 2" Non-CFC Foam Insulationl Water Connections—3/4" NPT l Heat Traps
l Protective Magnesium Anode Rodl T&P Relief Valvel Low Restriction Brass Drain Valve
50,00048LG2DV50H503N 93 725/16 min. 22 521/4 217154 6
NATURAL GAS MODELS Recovery100°F Rise*
A
Floor to C/L ofVent
1st HourRating(Gal.)
0.60
EnergyFactor
47
NatU.S.GPH
39
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
I.D. O.D.
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
591/8
F
Floor toTop ofHeater
8
H
C/L ofWaterConn.
601/8
J
Floor toWaterConn.
31
K
Depth
153/4
L
Floor toSpace
Heating Inlet
521/4
M
Floor toSpace
Heating Outlet
Approx.Shipping
Weight (lbs)
All Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”. For 5 year models change suffix from “3” to “5”.* Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
Solid Vent Kit: Part No. 239-51286-00. Weight: 22 lbs.Flexible Vent Kit: Part No. 239-51287-00. Weight: 13 lbs.Kits can be ordered and shipped with water heater, or ordered and shipped separately. For vent kit components and venting instructions, refer to Installation and Operation Manual.
LG2DV50H503N Optional Telescoping Solid Vent Kits:Kit “F” Telescopes from 43⁄4" to 511⁄16" Part No. 239-42516-00Kit “G” Telescopes from 61⁄2" to 93⁄16" Part No. 239-42517-00Kit “H” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-42514-00Kit “I” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-42512-00
InputBTU/Hr.
48,000LG2DV50H503X
LP GAS MODELS Recovery100°F Rise*
45
LPU.S.GPH
38
LPImp.GPH
ModelNumber
Light Duty Direct Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES
page 104
page 105
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofULG275H763NModel ULG2100H853N
B
C
K
A
J
E F
G
D
H
L
M
C
L
A
J
H
E F
D&G
BK
M
Models ULG250H3N & ULG275H763N
Commercial GasLight Duty Ultra Low NOx Atmospheric Vent High Input Models
106/107
l Bradford White ICON System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell
l Ultra Low NOx Burner with Primary and Secondary Air Distribution Devices
l Maintenance-Freel Sight Windowl Hydrojet 2™ Total
Performance Systeml Vitraglas® Liningl More Precise Temperature
Control l Side Connections—3/4" NPTl Non-CFC Foam Insulation
l Pedestal Base—ULG250&75l Water Connectionsl Protective Magnesium
Anode Rodl Hand Hole Cleanoutl 4" (107 mm) “Snap Lock”
Draft Diverterl T&P Relief Valvel Low Restriction Brass
Drain Valvel Design Certified by CSA
International (formerly AGA and CGA)
l ULG250H553N Complies with the Latest Ultra Low NOx Requirement (10 ng/J NOx limit), ULG275H763N / ULG2100H853N (14 ng/J NOx limit)
55,00076,00085,000
4875100
ULG250H553NULG275H763NULG2100H853N
100N/AN/A
605/16
641/8707/16
2226
281/4
497/8539/16
607/16
193263424
111/2151/8163/4
444
NATURAL GAS MODELS Recovery90°F Rise*
A
Floor to Flue Conn.
1st HourRating(Gal.)
0.60N/AN/A
EnergyFactor
597482
NatU.S.GPH
496269
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
133/8165/8183/4
F
Floor toSpace
HeatingReturn
497/8539/16
513/4
G
Floor toSpace
HeatingOutlet
563/8601/8681/8
H
Floor toTop ofHeater
5713/16
611/8665/8
J
Floor toWaterConn.
257/16
297/16
311/2
K
Depth
111116
L
C/Lof
WaterConn
3/41
11/4
M
NPT
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 5 year models, change suffix from “3” to “5”.* Based on manufacturer’s rated thermal efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
Light Duty Ultra Low NOx Atmospheric Vent High Input ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
79% Recovery EfficiencyDIMENSIONS IN INCHES
page 106
page 107
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
J
H
F
E
B K K
AA
C C
L
D&M
Photo ofULG2DV50H453N
Telescoping Solid Vent Kit (Side View) Flexible Vent Kit (Side View)
Commercial GasLight Duty Ultra Low NOx Direct Vent Model
108/109
l Bradford White ICON System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell
l Eco-Defender Safety System® - Digital Thermal Sensor
- Maintenance-Free - Sight Window - Pedestal Basel Ultra Low NOx Burner with Primary and
Secondary Air Distribution Devicesl Closed Combustionl Reinforced Sealsl Hydrojet® Total Performance Systeml Vitraglas® Liningl Cast Aluminum Air Intake Bootl Telescoping Solid Vent Kitsl Flexible Vent Kitl Side Connections—3/4" NPTl 2" Non-CFC Foam Insulationl Water Connections—3/4" NPT
l Heat Trapsl Protective Magnesium Anode Rodl T&P Relief Valve
l Low Restriction Brass Drain Valvel Design Certified by CSA International (formerly AGA and CGA)l Complies with the Latest Ultra Low NOx Requirement (10 ng/J
NOx limit)
45,00048ULG2DV50H453N 88 741/4 min. 22 521/4 201154 6
NATURAL GAS MODELS Recovery100°F Rise*
A
Floor to C/L ofVent
1st HourRating(Gal.)
0.60
EnergyFactor
43
NatU.S.GPH
35
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
I.D. O.D.
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
591/4
F
Floor toTop ofHeater
11
H
C/L ofWaterConn.
601/8
J
Floor toWaterConn.
305/8
K
Depth
153/4
L
Floor toSpace
Heating Inlet
521/4
M
Floor toSpace
Heating Outlet
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 5 year models change suffix from “3” to “5”.* Based on manufacturer’s rated recovery efficiency. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
Solid Vent Kit: Part No. 239-51286-00. Weight: 22 lbs.Flexible Vent Kit: Part No. 239-51287-00. Weight: 13 lbs.Kits can be ordered and shipped with water heater, or ordered and shipped separately. For vent kit components and venting instructions, refer to Installation and Operation Manual.
Optional Telescoping Solid Vent Kits:Kit “F” Telescopes from 43⁄4" to 511⁄16" Part No. 239-42516-00Kit “G” Telescopes from 61⁄2" to 93⁄16" Part No. 239-42517-00Kit “H” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-42514-00Kit “I” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-42512-00
Light Duty Ultra Low NOx Direct Vent Model Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES
page 108
page 109
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofULG2PV50H603N
BH
C
J
A
G
E
D
F
BH
C
J
A
G
E
D
F
Commercial GasLight Duty Ultra Low NOx TTW® Power Vent Model
110/111
l Ultra Low NOx Burner with Primary and Secondary Air Distribution Devices
l Eco-Defender Safety System® featuring the patented advanced ScreenLok® Technology flame arrestor design (except models above 75,000 BTU/Hr.) - Digital Thermal Sensor
- Flammable Vapor Sensor - Maintenance-Free - Sight Window - Pedestal Basel Bradford White ICON System™
- Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell
l Powerful Blower Motor - 10 ft. Power Cord Included (120 VAC)
l Horizontal and Vertical Ventingl Hydrojet® Total Performance
Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connections—3/4" NPTl Heat Trapsl Protective Magnesium Anode Rodl T&P Relief Valvel Low Restriction Brass Drain Valvel All Models Comply with the Latest
Ultra Low NOx Requirement (10 ng/J NOx limit) except ULG2PV75H763N (14 ng/J NOx limit)
56,00076,000
4875
ULG2PV50H563NULG2PV75H763N
99N/A
663/8691/4
2226
497/8517/8
190270
113/4113/4
3 or 43 or 4
NATURAL GAS MODELS Recovery100°F Rise*
A
Floor toVent
Conn.
1st HourRating(Gal.)
0.70N/A
EnergyFactor
5474
NatU.S.GPH
5462
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
565/8591/2
F
Floor toTop ofHeater
5861
G
Floor toWaterConn.
261/2301/4
H
Depth
1111
J
C/L ofWaterConn.
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 5 year models, change suffix from “3” to “5”.* Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
† For high altitude installations, consult the installation instructions.
3" Vent Pipe
ULG2PV50H563NULG2PV75H763N
4" Vent Pipe
†50 ft.7 ft.45 ft.40 ft.35 ft.
123
Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows
†180 ft.15 ft.175 ft.170 ft.165 ft.
Ultra Low NOx TTW® Power Vent Model Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery EfficiencyDIMENSIONS IN INCHES
page 110
page 111
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofULG2PDV50H503N
K
N
A
JF
EL
B
D & M
C
H
K
N
A
JF
EL
B
D & M
C
H
K
N
A
JF
EL
B
D & M
C
H
Commercial GasLight Duty Ultra Low NOx Power Direct Vent Models
112/113
l Ultra Low NOx Burner with Primary and Secondary Air Distribution Devices
Eco-Defender Safety System® - Digital Thermal Sensor
- Flammable Vapor Sensor - Maintenance-Free - Sight Window - Pedestal Basel Closed Combustion Venting
Systeml Bradford White ICON
System™ - Enhanced Performance - Advanced Temperature Control System - Intelligent Diagnostics - Separate Immersed Thermowell
l Cast Aluminum Air Intake Boot
l Hydrojet® Total Performance System
l Vitraglas® Liningl Optional Concentric Vent
Kit Terminationl Horizontal and Vertical
Ventingl 2" Non-CFC Foam Insulationl Water Connections— 3⁄4"
NPT l Side Connections—3/4" NPT l Heat Trapsl Protective Magnesium
Anode Rodl T&P Relief Valvel Low Restriction Brass
Drain Valvel Complies with the Latest
Ultra Low NOx Requirement (10 ng/J NOx Limit)
50,00048ULG2PDV50H503N 92 691/4 22 521/4 201137/83 or 4
NATURAL GAS MODEL Recovery100°F Rise*
A
Floor to ExhaustOutlet
1st HourRating(Gal.)
0.68
EnergyFactor
48
NatU.S.GPH
40
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
691/4
F
Floor toTop ofHeater
583/4
H
Floor toAir
Intake
60
J
Floor toWaterConn.
32
K
Depth
153/4
L
Floor toSpace
Heating Return
521/4
M
Floor toSpace
Heating Supply
91/4
N
C/LDistance
FromIntaketoExhaust
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 5 year models change suffix from “3” to “5”.* Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating are based on the latest AHRI directory listings.
Subtract 5ft. for each additional 90º elbow.
INTAKE/COMBUSTION
AIR
RAINCAP
VENTEXHAUST
A
3" Vent Pipe
ULG2PDV50H503N
4" Vent Pipe
60 ft.60 ft.7 ft.55 ft.50 ft.45 ft.
123
Max. Intake LengthMax. Exhaust LengthMin. Vent LengthNumberof90° Elbows
100 ft.100 ft.7 ft.95 ft.90 ft.85 ft.
3" Kit
P/N 239-44069-01 361/4
A (in.)
Light Duty Ultra Low NOx Power Direct Vent Model Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery EfficiencyDIMENSIONS IN INCHES
page 112
page 113
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofUCG-100H-199-3N
Commercial GasCommander Series™ Atmospheric Vent Models
114/115
l ICON HD™ - Operation Mode - Service Mode
l Optional Air Intake Ductingl Premix Power Burnerl Direct Spark Ignitionl Integrated Exhaust Systeml Sanitizing Capabilityl Hydrojet® Sediment Reduction
Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water Connectionsl 1" NPT Side Connections for
Space Heatingl 82% Thermal Efficiencyl Zero Inch Clearance to
Combustibles (Excluding UCG-100H-399)
l Hand Hole Cleanoutl NSF Construction Availablel T&P Relief Valvel Low Restriction Brass
Drain Valvel Ultra Low NOx Construction
(14 ng/J NOx Emissions)l CSA Certified Low Lead Content
125,000199,999270,000399,999199,999270,000399,999
8080808010010098
UCG-80H-125-3NUCG-80H-199-3N UCG-80H-270-3NUCG-80H-399-3NUCG-100H-199-3NUCG-100H-270-3NUCG-100H-399-3N
63643/4643/4683/4731/4731/4771/4
5668668
44444444
521/2521/2521/2
535535545545632632657
47474747
551/2551/2551/2
10101010101010
GPH Recoveryat Degree Rise*
Floor to Top ofVent
308493665960493665994
40°F
123197266384 197266398
100°F
88141190274141190284
140°FInput
BTU/Hr.Gal.Cap.
ModelNumber
Vent Dia.
Floorto ColdWaterInlet
Floor to T&P
Conn.
Floor toHot Water
Outlet
611/4611/4611/4611/4693/4693/4693/4
Floor toTop ofHeater
553/4553/4553/4553/4631/4631/4631/4
Floor toGas
Conn.
30303030303030
Depth
281/4281/4281/4281/4281/4281/4281/4
Width
543/4543/4543/4543/4631/4631/4631/4
Floor to Cold Water
Inlet/HotWater Outlet
A B C D E F G H J K
11/211/211/211/211/211/211/2
WaterConn.Dia.
3/43/43/43/43/43/43/4
GasConn.Dia.
3/43/411
3/411
ReliefValveOpen
Approx.Shipping
Weight (lbs)
NATURAL GAS AND LIQUID PROPANEGAS MODELS
Model
Optional Air Intake Ducting Maximum Lengths
UCG-80H-125-3(N,X)UCG-80H-199-3(N,X)UCG-100H-199-3(N,X)UCG-80H-270-3(N,X)UCG-100H-270-3(N,X)UCG-80H-399-3(N,X)UCG-100H-399-3N
20 ft.20 ft.20 ft.20 ft.20 ft.N/AN/A
50 ft.50 ft.50 ft.50 ft.50 ft.25 ft.25 ft.
75 ft.75 ft.75 ft.75 ft.75 ft.50 ft.50 ft.
2" PVC, ABS,or CPVC
3" PVC, ABS,or CPVC
4" PVC, ABS,or CPVC
For Propane Gas models change suffix “N” to “X”. Example: UCG-100H-199-3X (UCG-100H-399 available in Natural Gas only). Natural gas models comply with the latest Ultra Low NOx requirements (14 ng/J or less). Amp Draw range = 1.0 to 1.8 amps.
Commander Series™ Atmospheric Vent Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed82% Thermal EfficiencyDIMENSIONS IN INCHES
Optional Power Vent Kits – for side wall termination only.Model Numbers Kit NumberUCG-80H-125/199/270, UCG-100H-199/270: 239-81764-00UCG-80H-399, UCG-100H-399: 239-81766-00
page 114
page 115
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofD-80T-180-3N
Commercial GasElectronic Ignition Water Heaters
116/117
l ICON HD™—Intelligent proven design combines temperature control, diagnostic codes and system ignition functions into a single control board with a digital LCD display - Operation Mode - Service Mode
l Electronic Ignitionl Automatic Flue Damper
l Hydrojet® Sediment Reduction Systeml Vitraglas® Liningl Non-CFC Foam Insulationl Water connections—True dielectric waterway
fittingsl Hand Hole Cleanoutl Automatic Re-Set E.C.O.l Magnesium Anode Rodsl Sanitizing Capability
l ASME Code Available on All Models above 200,000 BTU/Hr.
l NSF Construction Availablel Low NOx Construction Availablel North Carolina Code Compliantl T&P Relief Valvel Low Restriction Brass Drain Valve
Commercial Gas Burnerl Orifice Alignment Bracket for True Injectionl Stainless Steel Pilot Shieldl Stainless Steel Burner Rack and
Mounting Bracketl Aluminized Steel Burner Tubes with
Adjustable Air Shutter (Stainless Steel Burner Tubes Available)
l Opposing Lance Formed Burner Ports Yield Consistent Performance to Stabilize Burner Flame and Promote Better Air Gas Mixture
l Standard on Both “T” and “L” Commercial Energy Saver Models
Optional Power Vent Kits – available for inputsfrom 125,000 to 505,000.BTU Input Range Kit Number125,000 to 290,000 BTU’s: 239-81764-00300,000 to 399,999 BTU’s: 239-81766-00425,000 to 505,000 BTU’s: 239-82148-00
Typical ApplicationsB
A
H
E
C
F
D
B
J
H
A
E
C
F
D
B
A
H
E
C
F
D
D-38T-155 D-75T-(125, 160)D-80T-(180, 199,250)D-100T-(199, 250)D-100S-(199, 250)D-100L-(199, 250, 270, 300)
D-75T-300D-65T-(370, 399)D-80T-(425, 505)D-80L-(399, 450, 505)
page 116
page 117
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Commercial GasElectronic Ignition Models
118/119
155,000125,000160,000180,000199,999250,000199,999250,000300,000370,000399,999425,000505,000
38757580808098987565658080
D-38T-155-3N+D-75T-125-3ND-75T-160-3ND-80T-180-3ND-80T-199-3ND-80T-250-3N(A)D-100T-199-3ND-100T-250-3N(A)D-75T-300-3N(A)D-65T-370-3N(A)D-65T-399-3N(A)†D-80T-425-3N(A)D-80T-505-3N(A)
177174208231250298263311344405424468527
37630338943648560648560672789797010301178
150121155175194242194242291359388412471
10786111124139173139173208256277294337
431/26565
641/2641/2641/2751/2751/2653/4643/4643/4751/2751/2
656666667881010
281/4281/4281/4281/4281/4281/4281/4281/4281/4281/4281/4281/4281/4
–––––
590–
690645720720800800
H
Floorto Top
ofHeater
B
JacketDia.
GPHRecovery
at °F Rise*
Approx.Shipping
Weight (lbs)
40° 100° 140° FirstHour**Rating
InputBTU/Hr.
Gal.Cap.
ModelNumber
VVVVVVVVVVVV
F V�������������
�
������������
�������������
� �
C
VentDia.
–671/8671/8661/4661/4661/4771/4771/4
–––––
J
Floorto TopWaterConn.
35541/2541/25656566767
541/8541/8541/8641/2641/2
D
FrontHot
WaterConn.
45/843/443/443/443/443/443/443/4101/2101/2101/2101/2101/2
E
Floorto GasConn.
51721/4721/4717/8717/8717/8833/8833/8743/8731/4731/4823/4823/4
A
TopVent
Height193/83434
191/2191/2191/2191/2191/22929292929
F
FrontCold
WaterConn. Std. ASME
11/2 (F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (F)
11/2 (F)
11/2 (F)
11/2 (F)
11/2 (F)
WaterConn.
3/43/43/43/43/43/43/43/43/4
1(N)
438520520540540540610610590665665750750
GasConn.Dia.
3/43/43/43/43/41
3/4111111
ReliefValveOpen.
NATURAL GAS MODELS
1(N)3/4 (LP)
1(N)3/4 (LP)
1(N)3/4 (LP)
1(N)3/4 (LP)
Electronic Ignition Models These models meet or exceed both Thermal Efficiency andStandby Loss Requirements of ASHRAE 90.1b (Current Edition).DIMENSIONS IN INCHES
199,999250,000199,999250,000270,000300,000399,999450,000505,000
100100100100100100808080
D-100S-199-3ND-100S-250-3N(A)D-100L-199-3ND-100L-250-3N(A)D-100L-270-3N(A)†D-100L-300-3N(A)D-80L-399-3N(A)D-80L-450-3N(A)D-80L-505-3N(A)
264312264312332361444492545
48560648560665572797010911224
194242194242262291388436489
139173139173187208277312350
677/8677/8643/4643/4643/4643/4601/4601/4601/4
66666781010
281/4281/4301/4301/4301/4301/4301/4301/4301/4
–702–
765765765835835835
H
Floorto Top
ofHeater
B
JacketDia.
GPHRecovery
at °F Rise*
Approx.Shipping
Weight (lbs)
40° 100° 140°FirstHour**Rating
InputBTU/Hr.
Gal.Cap.
ModelNumber
FF
VVVVVVVVVVV
F V�����������
�
�����������
�����������
� �
C
VentDia.
707067676767–––
J
Floorto TopWaterConn.
603/8603/8561/2561/2561/2561/2511/2511/2511/2
D
FrontHot
WaterConn.
45/845/841/241/241/241/2101/2101/2101/2
E
Floorto GasConn.
763/4763/4757575
753/8711/26969
A
TopVent
Height203/4203/4231/2231/2231/2231/2231/2231/2231/2
F
FrontCold
WaterConn. Std. ASME
WaterConn.
3/43/43/43/43/43/4
667667725725725725800800800
GasConn.Dia.
3/41
3/4111111
ReliefValveOpen.
NATURAL GAS MODELS
1(N)3/4 (LP)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (F)2 (R)
11/2 (F)2 (R)
11/2 (F)2 (R)
1(N)3/4 (LP)
1(N)3/4 (LP)
1(N)3/4 (LP)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (F)
11/2 (F)
11/2 (F)
(A) = ASME Code Available(F) = Front Water Connection(T) = Top Water Connection † = Available in Natural Gas Only + = Fiberglass InsulationFor (LP) Propane Gas models change suffix “N” to “X”.
* Based on manufacturer’s rated recovery efficiency.** Recoveries are based on 80% Thermal Efficiency . Low NOx models are not available for inputs over 399,999For Low NOx compliance place an “E” following the BTU input identifier of the model number. Example: D-75T-125E-3NAmperage Draw = .5 for damper models/less than 4 for induced draft models.Power Vent Kits – available for inputs from 125,000 to 505,000.
LP GAS MODELSInput
BTU/Hr.GPH Rec.
40° 100º 140º
D-75T-160-3X 155,000 376 150 107
D-80T-250-3X 235,000 570 228 163
D-100T-250-3X 235,000 570 228 163
D-80L-399-3X 375,000 909 364 260
D-80L-450-3X 425,000 1030 412 294D-80L-505-3X 475,000 1152 461 329
Electronic Ignition Models These models meet or exceed both Thermal Efficiency andStandby Loss Requirements of ASHRAE 90.1b (Current Edition).DIMENSIONS IN INCHES
page 118
page 119
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
E
F
D
A
C
G
39 7/8"DEPTH
B
E
F
D
A
C
G
39 7/8"DEPTH
B
Photo ofD-65T-625-3NA
Commercial GasInduced Draft Models
120/121
l ICON HD™—Intelligent proven design combines temperature control, diagnostic codes and system ignition functions into a single control board with a digital LCD display - Operation Mode - Service Mode
l Electronic Ignitionl Hydrojet® Total Performance Systeml Vitraglas® Liningl Automatic Re-Set E.C.O.l Non-CFC Foam Insulationl Water Connections—11⁄2" NPT front
true dielectric fittingsl Protective Magnesium Anode Rodsl Hand Hole Cleanoutl Sanitizing Capabilityl NSF Construction Availablel ASME Construction Available
l T&P Relief Valvel Low Restriction Brass Drain Valve
625,000725,000
6580
D-65T-625-3N(A)D-80T-725-3N(A)
15151757
606703
433502
693/8795/8
653/4743/4
281/4281/4
A
Floorto
HeaterTop
B
JacketDia.
GPHRecovery
at °F Rise*
40° 100° 140°
Nat. &LP
InputBTU/Hr.
Gal.Cap.
ModelNumber
VV
�
�
�
�
V � �
��
�F
J
Floorto TopWaterConn.
445/8445/8
GasConn.
88
C
VentDia.
687/8791/8
G
Floorto
VentHeight
203/4203/4
F
FrontCold
WaterConn.
541/8641/4
D
Floorto HotWaterConn.
287/8287/8
E
Floorto ColdWaterConn.
101/2101/2
F
Floorto GasConn.
695/8
785/8
A
TopVent
Height11
ReliefValveOpen
1†1†
GasConn.Dia.
WaterConn.
NATURAL GAS MODELS
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
775880
Approx.Shipping
Weight (lbs)
Std. ASME720800
(A) = ASME Code Available For Propane Gas models change suffix “N” to “X”.† LP Gas connection 3/4".* Based on manufacturer’s rated recovery efficiency.** Recoveries are based on Thermal Efficiencies of 80%.
Induced Draft Models These models meet or exceed both Thermal Efficiency and StandbyLoss Requirements of ASHRAE 90.1b (Current Edition). C.E.C. Listed
80% Thermal EfficiencyDIMENSIONS IN INCHES
page 120
page 121
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofDM-75T-125-3N
Commercial GasMillivolt Models
122/123
l No Electricity Requiredl ASME Code Available on All Models above 200,000 BTU/Hr.l Continuous pilot-ignitionl Piezo Igniter—Easy and quick lighting by the pilot burner by push buttonl Millivolt Controlsl Automatic Flue Damperl Vitraglas® Liningl Hydrojet® Sediment Reduction Systeml Dielectric Fittingsl Non-CFC Foam Insulationl Hand Hole Cleanout (Standard)l NSF Construction Availablel T&P Relief Valvel Low Restriction Brass Drain Valvel 3 Year Limited Tank Warranty
Water ConnectionsTop and FrontDM80T180, 199, 250DM100T199, 250DM75T125, 160Top FrontDM100L199, 250, 270DM100S199, 250
Water ConnectionsFront and RearDM38T155
C
B
F
J
D
E
COLD
HOT
T & P
A
H
CLEANOUT
H
C
B
F
D
E
HOT
T & P
A
J
COLD CLEANOUT
page 122
page 123
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
155,000125,000160,000180,000199,999250,000199,999250,000199,999250,000270,000199,999250,000
3875758080809898100100100100100
DM-38T-155-3NDM-75T-125-3NDM-75T-160-3NDM-80T-180-3NDM-80T-199-3NDM-80T-250-3N(A)DM-100T-199-3NDM-100T-250-3N(A)DM-100L-199-3NDM-100L-250-3N(A)DM-100L-270-3N(A)†DM-100S-199-3NDM-100S-250-3N(A)
174174208231250298264311264312332264312
368303378436485606485606485606655485606
147121151175194242194242194242262194242
10786108124139173139173139173187139173
436565
641/2641/2641/2751/2751/2656565
727/8727/8
6566666666666
281/4281/4281/4281/4281/4281/4281/4281/4301/4301/4301/4301/4301/4
—————590—690—765765—702
H
Floorto Top
ofHeater
B
JacketDia.
GPHRecovery
at °F Rise*
Approx.Shipping
Weight (lbs)
40° 100° 140°
FirstHour**Rating
InputBTU/Hr.
Gal.Cap.
ModelNumber F V �
�������������
�������������
� �
C
VentDia.
—671/8671/8661/4661/4661/4771/4771/46767677575
J
Floorto TopWaterConn.
341/2541/2541/25656566767
561/2561/2561/2601/2601/2
D
R/FHot
WaterConn.
45/843/443/443/443/443/443/443/441/241/241/241/241/2
E
Floorto GasConn.
51721/4721/4723/8723/8723/8833/8833/8757575
763/4763/4
A
TopVent
Height193/83434
191/2191/2191/2191/2191/2231/2231/2231/2203/4203/4
F
R/FCold
WaterConn. Std. ASME
WaterConn.
3/43/43/43/43/43/43/43/43/43/43/43/43/4
3/43/43/43/43/41
3/41
3/411
3/41
438520520540540540610610725725725667667
GasConn.Dia.
ReliefValveOpen.
NATURAL GAS MODELS
11/211/211/211/211/211/211/211/2
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/211/211/211/211/211/211/211/2
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
Commercial GasMillivolt Models
124/125
Millivolt Models These models meet or exceed both Thermal Efficiency andStandby Loss Requirements of ASHRAE 90.1b (Current Edition). C.E.C. ListedDIMENSIONS IN INCHES
(A) = ASME Code Available(F) = Front Water Connection(T) = Top Water Connection † = Available in Natural Gas Only For Propane Gas models change suffix “N” to “X”.
For LowNOx compliance, place an “E” following the BTU Input identifier of the model number. Example: DM-75T-125E-3N* Based on manufacturer’s rated recovery efficiency.** Recoveries are based on Thermal Efficiencies of 80%.
LP GAS MODELSInput
BTU/Hr.GPH Rec.
40° 100º 140ºDM-75T-160-3X 155,000 376 150 107DM-80T-199-3X 190,000 461 184 132DM-80T-250-3X 235,000 570 228 163DM-100T-250-3X 235,000 570 228 163
page 124
page 125
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
H
G
C
C
F
E
J
A
B
DCLEANOUT
21/2"
1/2"
MIN.
NPTCONDENSATECONNECTION
11/2"NPT
OUTLET
11/2"NPT
INLET
1" NPTSPACE
HEATINGOUTLET
1" NPTSPACE
HEATINGRETURN
3" PVCEXHAUST
3" PVC INLET 3/4" NPT GAS INLET
T&P VALVE
AIR INTAKE
GAS INLETEXHAUST
81/4"
81/4"
Photo of EF-60T-199E-3N
Commercial GasUltra High Efficiency Models
126/127
l ICON HD™—Intelligent proven design combines temperature control, diagnostic codes and system ignition functions into a single control board with a digital LCD display
l ASME Construction Availablel Electronic Controlsl Low-NOx Premix
Power Burnerl Three Pass Flue Systeml Flexible Venting Optionsl Vitraglas® Liningl Hydrojet® Sediment
Reduction Systeml Dielectric Fittings
l Non-CFC Foam Insulationl Four Protective Magnesium
Anode Rods (Except EF-100T-399)
l Two Powered Anode Rods and One Non-Powered Anode Rod in the EF-100T-399
l Hand Hole Cleanoutl Zero Inch Clearance
to Combustiblesl NSF Construction Availablel T&P Relief Valvel Low Restriction Brass
Drain Valvel Complies with the Latest
Ultra-Low NOx Requirement (14 ng/J NOx Limit)
606060100100100100100
VVVVVVVV
EF-60T-125E-3N(A)EF-60T-150E-3N(A)EF-60T-199E-3N(A)EF-100T-150E-3N(A)EF-100T-199E-3N(A)EF-100T-250E-3N(A)EF-100T-300E-3N(A)EF-100T-399E-3N(A)
187211265250309364405518
3644235584505977358361127
145169223180239294335451
104121159129171210239322
575757
775/8775/8775/8775/8775/8
421/2421/2421/2621/2621/2621/2621/263
281/4281/4281/4281/4281/4281/4281/4281/4
570570570900900900900950
H
Floor toTop ofHeater
55555555
J
Floor toVent
Conn.
B
JacketDia.
33333333
C
Vent& AirIntakeSize
GPHRecoveryat °F Rise
40° 100° 140°FirstHour**Rating
125,000150,000199,999150,000199,999250,000300,000399,999
InputBTU/Hr.
Gal.Cap.
ModelNumber V
��������
��
�
�
�
�
�
�
�
�
G
HotWaterOutletConn.
127/8127/8127/8127/8127/8127/8127/813
F
ColdWaterInlet
Conn.531/2531/2531/2743/4743/4743/4743/4741/4
521/2521/2521/2731/8731/8731/8731/8731/8
E
Floorto GasConn.
51/851/851/851/851/851/851/851/8
F
Floorto VentOutlet
A
Floorto AirIntake
3/43/43/43/43/43/43/41
GasConn.Dia.
3/43/43/43/43/4111
ReliefValveOpen
11/211/211/211/211/211/211/211/2
WaterConn.
4040406060606060
D
Floorto T&PValveConn.
Approx.Shipping
Weight (lbs)
NATURAL GAS AND LIQUID PROPANE GAS MODELS
(A) = ASME Code Available For Propane Gas models change suffix “N” to “X” and remove “E” from model number Example: EF-100T-150-3X. Note: The weight is the same for both ASME and Non-ASME models. NSF Compliance Kit—p/n 265-44542-04. ** Recoveries are based on the listed Thermal Efficiencies.
Ultra High Efficiency Models These models meet or exceed both Thermal Efficiencyand Standby Loss Requirements of ASHRAE 90.1b (Current Edition). C.E.C. ListedDIMENSIONS IN INCHES
page 126
page 127
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Commercial GasUltra High Efficiency Models
128/129
Max. Intake LengthMax. Exhaust Length
15 ft.15 ft.
N/A30 ft.
PowerDirect Vent
PowerVent
EF-60T-125
15 ft.15 ft.
N/A30 ft.
PowerDirect Vent
PowerVent
EF-60T-150EF-100T-150
15 ft.15 ft.
N/A30 ft.
PowerDirect Vent
PowerVent
EF-60T-199EF-100T-199
2” Vent Pipe
Max. Intake LengthMax. Exhaust Length
60 ft.60 ft.
N/A120 ft.
PowerDirect Vent
PowerVent
EF-60T-125EF-100T-150
50 ft.50 ft.
N/A100 ft.
PowerDirect Vent
PowerVent
EF-60T-150EF-100T-199
40 ft.40 ft.
N/A80 ft.
PowerDirect Vent
PowerVent
EF-60T-199EF-100T-250
30 ft.30 ft.
N/A60 ft.
PowerDirect Vent
PowerVent
EF-100T-300
25 ft.25 ft.
N/A50 ft.
PowerDirect Vent
PowerVent
EF-100T-399
3” Vent Pipe
Max. Intake LengthMax. Exhaust Length
85 ft.85 ft.
N/A170 ft.
PowerDirect Vent
PowerVent
EF-60T-125EF-100T-150
75 ft.75 ft.
N/A150 ft.
PowerDirect Vent
PowerVent
EF-60T-150EF-100T-199
65 ft.65 ft.
N/A130 ft.
PowerDirect Vent
PowerVent
EF-60T-199EF-100T-250
55 ft.55 ft.
N/A110 ft.
PowerDirect Vent
PowerVent
EF-100T-300
50 ft.50 ft.
N/A100 ft.
PowerDirect Vent
PowerVent
EF-100T-399
4” Vent Pipe
eF Series® Optional Equipment Features:
Maxitrol Gas Pressure Regulating Valve—Ensures proper supply pressure to eF unit of 7" to 11" W.C.(provided incoming pressure is between 1/2 and 2 psi). This can be ordered as a separate part, or as part of the heater. For the separate part, please use p/n 243-45517-00 (not available for use with the EF-100T-399).
NSF Compliance Option—p/n 265-44542-04
Low Gas Inlet Pressure Option—Pre-assembled to allow operation at lower inlet natural gas pressure.
Intake/CombustionAir Rain Cap
VentExhaust
36 1/4"
Concentric Vent Terminal Kit—3” termination fitting provides for only one exit opening through wall or roof (p/n 239-44069-01).
p/n 239-44069-01p/n 239-44069-02 (for 2” vent pipe only)
page 128
page 129
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Incoloy Element Availability Chart
yesnonononononononono
120V
1500200025003000350040004500500055006000
Watts
yesyesyesyesyesyesyesyesyesyes
208V
yesyesyesyesyesyesyesyesyesyes
240V
noyesnoyesnoyesyesyesyesyes
277V
noyesnoyesnoyesyesyesyesyes
480V
Commercial ElectricWater Heaters
130/131
Specify voltage and wattage when ordering.
All models are ETL listed. All water connections are 3⁄4" NPT (LE2120T has 1" NPT). All electrical connections are 3⁄4". All models are certified at 300 psi test pressure and 150 psi working pressure. All models come equipped with two installed heat traps (except LE2120T, LE120L, Utility and Wall Hung models). All models include an installed T&P Relief Valve.
Note: All Upright and Lowboys will be wired 240 Volt with two 4500 watt elements, 3 phase non-simultaneous operation (except 277 volt; 277 volt is only available in single phase operation). Other wattages and voltages are available. These models are field convertible to single phase and simultaneous operation. All models have a maximum total wattage of 3000 watts at 120 Volt. Incoloy® elements available for most inputs.
Note: All Wall Hung and Utility Models will be wired 120 Volt with a 1500 watt element as single phase operation. 3 phase wiring not available on Wall Hung or Utility models (Single Element Units). Other wattages and voltages are available. Maximum wattage for 6 and 12 gallon tall utility models is 3000W. Maximum wattage for 10, 12 and 15 gallon utility models is 6000W. Maximum wattage for the 6 gallon wall hung model is 3000W. Maximum wattage for 12, 20 and 30 gallon wall hung models is 6000W. All models have a maximum wattage of 3000 watts at 120 Volt. Incoloy® elements available for most inputs.
Wattage Limitations for Non-Simultaneousand Simultaneous Operation
Voltage120V 208V 240V 277V 480V
Recovery�GPH Temperature Rise ºF
60 80 90 100 120Wattage
yesnonononononononono
yesyesyesyesyesyesyesyesnono
yesyesyesyesyesyesyesyesyesno
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
NOTE: WHEN ORDERING WATER HEATERS SPECIFY VOLTAGE AND kW INPUT ONLY. THE FOLLOWING TABLES ARE FOR INFORMATIONAL PURPOSES ONLY.Phase and Operation are determined by the voltage. All 208V, 240V and 480V models are shipped standard three phase, non-simultaneous. Can be converted to single phase and/or simultaneous operation in the field.All 120V and 277V models are shipped standard single phase, non-simultaneous. Can be converted to simultaneous operation in the field. Three phase not available.
EX: LE250S3-3NCWW EX: LE250S3-3NCWW
EX: LE250S3-3NCWW
EX: LE250S3-3ge designator if wiring 208V with 5000, 5500 or 6000 watt. † Available in non-simuNCWW, will give 240V with 4500W/4500W. This same heater can also be energized at 208V with reduced wattage of 3500W/3500W. ** Use “L” voltaltaneous only.
EX: LE250S3-3NCWW* Use “L” voltage designator if wiring 208V with 5000 watt.
For 120V, 277V, 480V, and 600V operation
For 240V and 208V operation (Dual rated elements show a value for both 240V and 208V)
Phase1 Single Phase3 Three Phase
OperationN Non-SimultaneousS Simultaneous
Designator A C E H J L*Voltage 120 208/240 277 480 600 208
Designator J K L M N P R S T W X Y ZWattage 1000 1250 1500 2000 2500 3000 3500 3800 4000 4500 5000 5500 6000
Designator J K L M N P R S T W X Y Z X** Y** Z**240V Wattage 1000 1250 1500 2000 2500 3000 3500 3800 4000 4500 5000 5500 — — — —208V Wattage — — 1000 1500 2000 — 2500 — 3000 3500 — 4000 4500 5000 — —
page 130
page 131
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofLE250S3-3
B
C
A
D
B
C
A
D
Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)
Commercial ElectricElectriFLEX LD™ (Light Duty) Upright Models
132/133
l Fully Automatic Controlsl Direct Heat Transfer with Immersed Elementsl Hydrojet® Total Performance Systeml Vitraglas® Liningl 2" Non-CFC Foam Insulationl Water Connections—3⁄4" NPTl Heat Traps l Protective Magnesium Anode Rodl Steel Tankl Field Convertiblel Voltages Available—120V, 208V, 240V, 277V, 480V.l T&P Relief Valve
3040506580119
LE230S3-3LE240S3-3LE250S3-3LE265T3-3LE280T3-3LE2120T3-3
467/8467/8461/2591/4591/4623/4
182022222428
473/16
467/8461/2591/4591/4621/4
85103130156183305
481/8477/8471/2601/4601/4641/4
ELECTRIC MODELS Recovery100°F Rise*
A
Floor toHeater Top
181818181818
NatU.S.GPH
151515151515
NatImp.GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor toWater Conn.
D
Floor toT&P Conn.
Approx.Shipping
Weight (lbs)
Specify wattage and voltage when ordering. Use chart below for maximum wattages at certain voltages For 5 year models, change suffix “3” to “5”.* Based on 4500W/4500W, Non-Simultaneous operation. NSF Kits available when ordering.
s (GPH based on Non-Simultaneous operation, when Simultaneous operation the GPH will approximately double.)
Wattage Limitations for Non-Simultaneousand Simultaneous Operation
Voltage120V 208V 240V 277V 480V
Recovery�GPH Temperature Rise ºF
60 80 90 100 120Wattage
yesnonononononononono
yesyesyesyesyesyesyesyesnono
yesyesyesyesyesyesyesyesyesno
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
Wattage Limitations for Non-Simultaneousand Simultaneous Operation
Voltage120V 208V 240V 277V 480V
Recovery�GPH Temperature Rise ºF
60 80 90 100 120Wattage
yesnonononononononono
yesyesyesyesyesyesyesyesnono
yesyesyesyesyesyesyesyesyesno
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
ElectriFLEX LD™ (Light Duty) Upright ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES
page 132
page 133
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofLE120S3-3
B
C
A
D
B
C
A
D
Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)
Commercial ElectricElectriFLEX LD™ (Light Duty) Lowboy Models
134/135
l Fully Automatic Controlsl Direct Heat Transfer with Immersed
Elementsl Hydrojet® Total Performance Systeml Vitraglas® Liningl 1" Non-CFC Foam Insulationl Water Connections—3⁄4" NPT l Heat Trapsl Protective Magnesium Anode Rodl Steel Tankl Field Convertiblel Voltages Available—120V, 208V, 240V,
277V, 480Vl T&P Relief Valve
19304047
LE120L3-3†LE130L3-3**LE140L3-3**LE150L3-3**
243/4293/4311/4313/4
18202224
191/4 / 247/824 / 293/8
241/8 / 313/4241/8 / 313/4
5886115140
2631
327/8331/8
ELECTRIC MODELS Recovery100°F Rise*
A
Floor toHeater Top
18181818
NatU.S.GPH
15151515
NatImp.GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor toWater Conn.
D
Floor toT&P Conn.††
Approx.Shipping
Weight (lbs)
s (GPH based on Non-Simultaneous operation, when Simultaneous operation the GPH will approximately double.)
Wattage Limitations for Non-Simultaneousand Simultaneous Operation
Voltage120V 208V 240V 277V 480V
Recovery�GPH Temperature Rise ºF
60 80 90 100 120Wattage
yesnonononononononono
yesyesyesyesyesyesyesyesnono
yesyesyesyesyesyesyesyesyesno
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
Wattage Limitations for Non-Simultaneousand Simultaneous Operation
Voltage120V 208V 240V 277V 480V
Recovery�GPH Temperature Rise ºF
60 80 90 100 120Wattage
yesnonononononononono
yesyesyesyesyesyesyesyesnono
yesyesyesyesyesyesyesyesyesno
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
Specify wattage and voltage when ordering. Use the charts to the right for maximum wattages at certain voltages. All Models include supplied insulation blanket. For 5 year models, change suffix “3” to “5”.* Based on 4500W/4500W, Non-Simultaneous operation.** Models include supplied insulation blanket (2" thick). Dimensions in charts above do not include blanket thickness NSF Kits available when ordering.† Exempt from ASHRAE 90.1b.†† All models feature side T&P location and must specify top T&P when ordering. “D” dimension listed as side/top.
ElectriFLEX LD™ (Light Duty) Lowboy ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES
page 134
page 135
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
4" ALTERNATECOLD INLET(PLUGGED)6 & 12 GAL.
ONLY
PLUG TYPEANODE6 & 12
GAL. ONLY
ALTERNATE HOTOUTLET (PLUGGED)
6 & 12 GAL. ONLY
8"
B
F
F
C
E
D
A
B
C D
F
E
A
Photo ofLE112T3-1
Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)
6, 12, & 20 Gallon Models
10 & 15 Gallon Models
Commercial ElectricElectriFLEX LD™ (Light Duty) Utility Models
136/137
l Fully Automatic Controlsl Direct Heat Transfer with a Single
Immersed Elementl Vitraglass® Liningl 1" Non-CFC Foam Insulationl Water Connections—3/4" NPT l Alternate Top Water Connectionsl Protective Magnesium Anode Rodl Steel Tankl Voltages Available—120V, 208V, 240V,
277V, 480Vl Single Phase Operation Onlyl T&P Relief Valve
610121519
LE16U3-1†LE110U3-1LE112T3-1†LE115U3-1LE120U3-1
161/2171/2273/4201/4243/4
1416141818
101/814
211/8
163/4181/4
3348485559
101/815
211/8173/4181/4
ELECTRIC MODELS Recovery100°F Rise*
A
Floor toHeater Top
66666
NatU.S.GPH
55555
NatImp.GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor to Hot Water Conn.
31/8
511/16
361/83
E
Floor to ColdWater Conn.
161/2
911/16
273/4101/8101/4
F
Floor toAnode Rod
D
Floor toT&P Conn.
Approx.Shipping
Weight (lbs)
WattageLimitations 120V 208V 240V 277V 480V
RecoveryGPH Temperature Rise ºF
60 80 90 100 120Wattage
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
VoltageWattage
Limitations 120V 208V 240V 277V 480V
RecoveryGPH Temperature Rise ºF
60 80 90 100 120Wattage
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
Voltage Specify wattage and voltage when ordering. Use chart to right for maximum wattages at certain voltages.† Maximum wattage at any voltage is 3000W. For 5 year models, change suffix “3” to “5”. Single element only.* Based on 1500W operation. NSF Kits available when ordering.
ElectriFLEX LD™ (Light Duty) Utility ModelsC.E.C. ListedDIMENSIONS IN INCHES
page 136
page 137
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofLE16WV3-1
TOPVIEW
D
C
WALL
HOTOUTLET
COLDINLET
ELECTRICAL JUNCTION BOX
8"
A AFRONTVIEW
1213/16"D
HOT OUTLET3/4" CONN.
COLD INLET3/4" CONN.
E
3/4" RELIEF VALVE OPENING
SIDEVIEW
WALL
B
BOTTOMVIEW
FRONT
HEATINGELEMENT &THERMOSTATACCESS
B
Copper Screw Type Immersion Element(Incoloy® type immersion element available upon request)
Commercial ElectricElectriFLEX LD™ (Light Duty) Wall Hung Models
138/139
l Fully Automatic Controlsl Direct Heat Transfer with a Single
Immersed Elementl Vitraglas® Liningl 1" Non-CFC Foam Insulationl Heavy-Duty Wall Mounting Bracketl Water Connections—3/4" NPT
l Protective Magnesium Anode Rodl Steel Tankl Voltages Available—120V, 208V,
240V, 277V, 480Vl Single Phase Operation Onlyl T&P Relief Valve
61219
LE16WV3-1†LE112WV3-1LE120WV3-1
153/4163/8243/8
141818
113/4123/4181/4
334859
145/8185/8185/8
ELECTRIC MODELS Recovery100°F Rise*
A
Height
666
NatU.S.GPH
555
NatImp.GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Wall toFront
117/8
121/221
E
Height toT&P Conn.
D
Height toBracket
Approx.Shipping
Weight (lbs)
WattageLimitations 120V 208V 240V 277V 480V
RecoveryGPH Temperature Rise ºF
60 80 90 100 120Wattage
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
VoltageWattage
Limitations 120V 208V 240V 277V 480V
RecoveryGPH Temperature Rise ºF
60 80 90 100 120Wattage
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
Voltage
Specify wattage and voltage when ordering. Use chart to right for maximum wattages at certain voltages. † Maximum wattage at any voltage is 3000W. For 5 year models, change suffix “3” to “5”. Single element only.* Based on 1500W operation. NSF Kits available when ordering.
ElectriFLEX LD™ (Light Duty) Wall Hung ModelsC.E.C. ListedDIMENSIONS IN INCHES
page 138
page 139
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofE32-80R-3
A&DC
B
F
E10"
8"
3 1/8"
A&DC
B
F
E10"
8"
3 1/8"
Commercial ElectricElectriFLEX MD™ (Medium Duty) Models
140/141
l Vitraglas® Liningl Hydrojet® Total Performance Systeml Water Connections—11⁄4" NPT dielectric waterway fittingsl 2" Non-CFC Foam Insulationl Fully Automatic Controls (180°F maximum)l Direct Heat Transfer with Immersed Elementsl Protective Magnesium Anode Rodl T&P Relief Valvel Low Restriction Brass Drain ValveOptional Field Conversion Kits; see next page for part numbers NSF Construction Kits; see next page for part numbers
32,00030,00040,00040,00040,00050,00040,00040,00050,00040,00076,00085,000
5080119
E32-50S-3E32-80R-3E32-120R-3
50 2059 1/8483/858
59 3/850
603/459 5/8493/4581/2603/4633/46811/16
2224
281/4
461/25963
137190312
245/8263/4307/8
ELECTRIC MODELS A
Floorto FlueConn.
B
JacketDia.
GPHRecovery
90°F Rise*
1st Hour**DeliveryRating
InputBTU/Hr.
GallonCapacity
ModelNumber
A
Floor toHeater Top
471/26064
C
Floor toWater Conn.
447/8573/8613/8
E
Floor to Control Box
475/8601/8641/8
D
Floor toT&P Conn.
F
Control Boxto Back
of Heater
Approx.Shipping
Weight (lbs)
All Medium Duty heaters are wired 240V/3 phase 18 kW. Other voltages, wiring phase and kW are available and must be specified when ordering. NOTE: Refer to pages 130/131 for technical information and pages 150/151 for GPH recovery information.
RequiredTotal
HeaterWattage
ElementWattage
Kit Part Numbers
208V
Conversion Kit Table
240V 480V60009000
12000135001500018000
200030004000450050006000
265-43942-13265-43942-14265-43942-15265-43942-16265-43942-17265-43942-18*
265-43942-07265-43942-08265-43942-09265-43942-10265-43942-11265-43942-12
265-43942-01265-43942-02265-43942-03265-43942-04265-43942-05265-43942-06
208V 240V 277V
Full Load Amperes - (Single Phase / Three Phase) and Recovery at a 100°F Rise
380V 415V 480V Recovery28.8/16.743.2/25.057.7/33.364.9/37.572.1/41.686.5/50.0
Input kW6912
13.51518
25.0/14.437.5/21.750.0/28.956.3/32.562.5/36.175.0/43.3
21.732.543.348.754.265.0
9.113.718.220.522.827.3
8.312.516.718.820.925.0
12.5/7.218.8/10.825.0/14.428.1/16.231.3/18.037.5/21.7
25 GPH37 GPH50 GPH56 GPH62 GPH74 GPH
ModelNumber Kit Part Numbers
NSF Construction Kit
E32-50SE32-80RE32-120R
265-45446-01265-45446-02265-45446-03
1,000 watts = 1kW.* 265-43942-18 will require control box replacement (included in kit). Other wattages, wiring phase and kW are available and must be specified when ordering. 277 volt cannot be ordered as 3 phase operation.
ElectriFLEX MD™ (Medium Duty) ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES
page 140
page 141
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
E C
DA
B
F
Photo ofCEHD80(A)-KW-3CF
Commercial ElectricElectriFLEX HD™ (Heavy Duty) Models
142/143
Immersion Thermostat with Contactorsl Immersion Type Thermostat for
Accurate Temperature Control from Positive off up to 180°F
All Models Featurel Vitraglas® Lined Tankl Hydrojet® Sediment Reduction
Systeml Completely Pre-wired with Pressure
Lug Terminal Eliminating the Need for Splicing or Taping Wires
l Water Connections—11⁄2" NPT true dielectric fittings
l 3" Non-CFC Foam Insulationl Two Protective Magnesium
Anode Rodsl Hand-hole Cleanout Openingl Internal Fusing—Standard on all
models
l Low Restriction Brass Drain Valvel T&P Relief ValveOptionsl ASME & NSF Construction
Available
300,000360,000
5080119
CEHD50(A)-KW-3CFCEHD80(A)-KW-3CFCEHD120(A)-KW-3CF
347419
728873
291349
208249
503/16
60641/2
461/2461/2501/4
2426
301/4
493/4 / 563/8 383/4
493/4 / 551/450 / 565/841 / 471/4511/2 / 5850 / 567/8
401/2 50 / 553/4501/2 / 58
33595/16
A
Floor to Heater
Top
B
JacketDia.
GPHRecovery
at Degree Rise*
40° 100° 140°
1st HourDeliveryRating
Nat. &LP
InputBTU/Hr.
Gal.Cap.
ModelNumber
E
Floor toCold
WaterInlet611/16
611/16
63/4
F
Floor toTop ofControl
Box525/8651/2663/4
D
Floor toHot
WaterOutlet
407/16
511/2549/16
C
Floor toT&P
Conn.WaterConn.
ELECTRIC MODELS 11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
302378485
Approx.Shipping
Weight (lbs)
Std. ASME270335430
11/211/211/2
Voltage and phase must be specified when ordering. Example: CEHD50-12-3CF, 240 Volt, 3 phase.All models available in 208/240/277 and 480 volt.(A) ASME Construction available.For ASME construction add “A” to the model number.Example: CEHD50A-12-3CF, 240 Volt, single phase.NOTE: Refer to pages 130/131 for technical information and pages 150/151 for GPH recovery information.
HOT
COLD45°
15 1/8"
22 1/8"19 1/2"
HOT
COLD 52°
13"
56°T & P 47°
T & P
HOT
COLD 58°
12"
18 1/2"
63°T & P
CEHD50 CEHD80 CEHD120
ElectriFLEX HD™ (Heavy Duty) ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES
page 142
page 143
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
E C
DA
Hot
B
T&PValve
ColdWaterSupply
F
Photo ofM-II-50-36-3SF
Commercial ElectricSurface and Immersion Thermostat Models
144/145
Immersion Thermostat with Contactorsl Immersion Type Thermostat for
Accurate Temperature Control from Positive off up to 180°F
Surface Mounted Thermostatsl Thermostat Step Control Can Be
Accomplished by Variable SettingsAll Models Featurel Vitraglas® Lined Tankl Hydrojet® Sediment Reduction
Systeml Completely Pre-wired with Pressure
Lug Terminal or Fuse Block Eliminating the Need for Splicing or Taping Wires
l Water Connections—11⁄2" NPT true dielectric fittings
l 3" Non-CFC Foam Insulation
l Two Protective Magnesium Anode Rods
l Hand-hole Cleanout Openingl Low Restriction Brass Drain Valvel T&P Relief ValveOptionsl ASME & NSF Construction
Available on Immersion and Surface Thermostats
300,000360,000
5080119
M-II-50-kW-3SFM-II-80-kW-3SFM-II-120-kW-3SF
347419
728873
291349
208249
473/4601/4641/2
461/2461/2501/4
2426
301/4
493/4 / 563/8 383/4
493/4 / 551/450 / 565/841 / 471/4511/2 / 5850 / 567/8
401/2 50 / 553/4501/2 / 58
33595/16
A
Floor to Heater
Top
B
JacketDia.
GPHRecovery
at Degree Rise*
40° 100° 140°
1st HourDeliveryRating
Nat. &LP
InputBTU/Hr.
Gal.Cap.
ModelNumber
E
Floor toTop ofControl
Box63/463/463/4
F
Floor toCold
WaterInlet
491/4613/466
D
Floor toHot
WaterOutlet
41521/255
C
Floor toT&P
Conn.WaterConn.
ELECTRIC MODELS 11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
11/2 (T&F)2 (R)
302378485
Approx.Shipping
Weight (lbs)
Std. ASME270335430
11/211/211/2
Model numbers shown are for Surface Mount thermostats. For Immersion thermostat change suffix “SF” to “CF”.Voltage and phase must be specified when ordering. Example: M-II-50-12-3SF, 240 Volt, 3 phase.All models available in 208/240/277 and 480 volt.(A) ASME Construction available.For ASME construction add “A” to the model number.Example: M-II-50A-12-3SF, 240 Volt, single phase.NOTE: Refer to pages 130/131 for technical information and pages 150/151 for GPH recovery information. HOT
COLD45°
15 1/8"
22 1/8"19 1/2"
HOT
COLD 52°
13"
56°T & P 47°
T & P
HOT
COLD 58°
12"
18 1/2"
63°T & P
M-II-50 M-II-80 M-II-120
Surface and Immersion Thermostat ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedDIMENSIONS IN INCHES
page 144
page 145
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
T&P
DRAIN
HI/LOWPRESSURE
B
A
E
ANODE
T&P VALVE
OUTLET
F
D
C
CLEANOUTNOTAVAILABLEON 6/12 GAL.
Photo of30A-36-3
Commercial ElectricASME Models
146/147
Standard Features:l Immersion Thermostat with
Contactors - Immersion Type Thermostat for Accurate Temperature Control from Positive Off up to 180°F
l ASME Code Constructionl Vitraglas® Liningl Commercial Hydrojet® Sediment
Reduction Systeml Completely Pre-Wired With Pressure
Lug Terminal or Fuse Block Eliminating the need for Splicing or Taping Wires
l Dielectric Fittingsl Non-CFC Foam Insulation 2" For 6-40 Gallon 3" For 50-119 Gallon
l Protective Magnesium Anode Rodl Handhole Cleanout Opening (20 thru
120 Gallon Models Only)l T&P Relief Valvel Low Restriction Brass Drain ValveOptions:l Low Water Cut-Off Switchl Safety Door Interlockl High and Low Pressure Limit Switchesl Alarm Hornl Temperature and Pressure Gaugel Time Delay Step Sequences (24kW
and Above)l NSF Construction
39183636818181
6122030405080119
6A-kW-312A-kW-320A-kW-330A-kW-340A-kW-350A-kW-380A-kW-3120A-kW-3
55 33171/428
271/238
481/4473/4601/4641/2
16162020202426
301/4
1728273838
461/2461/2501/4
181/16
2815/16
28401/4501/2503/8617/8665/16
83118145180220270335430
61/461/461/461/461/4666
181/4 29
281/239
491/4491/4613/466
ELECTRIC MODELS A
Floor to Heater
Top
B
JacketDia.
GPHRecovery
90°F Rise*
1st Hour**DeliveryRating
Max.kW Input
Gal.Cap.
ModelNumber
C
Floor to Top of
Control Box
D
Floorto HWOutlet
E
Floorto T&PValve
F
Floorto CWInlet
3/43/43/43/43/411/211/211/2
WaterConn.
Approx.Shipping
Weight (lbs)
COLDCOLD
HOT
78°
10"
14 1/2"
20A, 30A, 40A
13"
HOT
87°
8"
12A
87°78°
COLD
T & P T & P T & P
DRAIN
HOT
75°
8"
13"
6A
75° DRAINDRAIN
HOT
COLD45°
15 1/8"
22 1/8"
120A
19 1/2"
HOT
COLD 52°
13"
80A
56°T & P 47°
T & P
HOT
COLD 58°
12"
18 1/2"
50A
63°T & P
NOTE: Refer to pages 150/151 for GPH recovery information.
ASME ModelsDIMENSIONS IN INCHES
page 146
page 147
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
TEMPERATURE& PRESSURERELIEF VALVEHOT
WATEROUTLET
HANDHOLECLEANOUT
DRAIN
COLDWATERINLET TOP VIEW
6 1/4"
D
HINGED DOORTO ELECTRICALCOMPARTMENT
B
E
A
C
Photo ofVR-200-36
Commercial ElectricBrute Vertical Round Models
148/149
Standard Features:l 150 psi ASME Code Tankl Lifting Lug Accessl Incoloy® Heating Elementsl Vitraglas® Liningl Internal Fusingl Galvanized Steel Jacketl Magnesium Anode Rodsl Immersion Thermostatl Manual Reset High Limitl Hinged Door with
Keyed Lockl Temperature and Pressure
Relief Valvel Channel Iron Skid Basel Hand Hole Cleanoutl 180°F Operationl Three Year Limited Warrantyl Meets or Exceeds ASHRAE 90.1b
(Current Edition)
Optional Equipment Features:l Low Water Cut-Offl Pilot Lightsl Manual Limiting Switchesl Alarm Belll Low or High Pressure Switchl Time Clock (7 Day or 24 Hour)†
l Safety Door Interlockl Temperature and Pressure Gaugel Manhole Cleanout (250 Gallons
and Larger)l Electronic Sequencer (36kW
& Higher)l Shunt trip disconnect†
l BMS Relay†Separate mounting
150200250300400500600
VR-150-kWVR-200-kWVR-250-kWVR-300-kWVR-400-kWVR-500-kWVR-600-kW
383/4 383/4 403/4 463/4523/4 523/4 603/4
32323440464654
73/473/4191/221
221/2221/2241/2
65075011651350159017002010
16171720232327
651/2 789280809292
ELECTRIC MODELS D
Depth
90162162162162162162
Max.kW Load**
Gal.Cap.
ModelNumber
B
Jacket
Diameter
A
Floor toTop ofHeater
C
Floor toCold Water
Inlet
E
Back of Heaterto Cold
Water Inlet
11/211/211/2222
21/2
WaterConn.
Approx.Shipping
Weight (lbs)
NOTE: Refer to pages 150/151 for GPH recovery information.** Vertical Round models above 90kW at 208V, 240V or 380V, and 162kW at 400V, 415V or 480V, exceed the capacity of a single control panel and may require multiple control panels. Consult the factory for specific details and optional construction.
Brute Vertical Round ModelsDIMENSIONS IN INCHES
page 148
page 149
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
kWInput
Gallon Per Hour Recovery Capacities
40°F1
1.52
2.53
3.54
4.55
5.56912
13.515182427
10.315.520.725.831.136.241.446.551.756.962.193.1124140155186248279
60°F6.910.313.817.220.724.127.631.134.537.941.462.18393103124165186
90°F4.66.99.211.513.816.118.420.723.125.327.641.455626983110124
100°F4.16.28.310.312.414.516.518.620.722.724.837.25056627499112
140°F2.94.45.97.48.910.311.813.314.716.217.726.5354044537180
Commercial ElectricGPH Recovery Table for kW Input
150/151
kWInput
Gallon Per Hour Recovery Capacities
40°F3036455481144162180225270360396450540630720900
310372465558838148916751861232627923722409446535583651474449306
60°F20724831037255899311171241155018612482273031023722434349636204
90°F138165207248372662744827103312411654182020682482289533094136
100°F12414918622333559667074493111171489163818612233260629783722
140°F891061331602394254795326657981063117013291595186121272659
GPH Recovery Table
page 150
page 151
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
DA F
EG
C
B
D DA
F
F
E EG G
C C
B
A
B
POTABLECONNECTIONS
ANODE RODS(TYPICAL)
(TYPICAL)ANODE RODS
(TYPICAL)
POTABLECONNECTIONS
(TYPICAL)
Photo of SW-65C-5
SW-65C-5SW-80C-5SW-120C-5
DA F
EG
C
B
D DA
F
F
E EG G
C C
B
A
B
POTABLECONNECTIONS
ANODE RODS(TYPICAL)
(TYPICAL)ANODE RODS
(TYPICAL)
POTABLECONNECTIONS
(TYPICAL)
CommercialPowerStor Series® Single-Wall Indirect Models
152/153
l Heat Exchanger—Single-wall 11⁄2" O.D. enamel coated (Vitraglas®) steel coil
l Vitraglas® Liningl Hydrojet® Total Performance Systeml Water Connections—1" NPT true dielectric
fittings l 1" NPT Connection for Boiler Supply
and Returnl 2" Non-CFC Foam Insulationl Immersion Type Aquastat—Accurate
temperature controll Three Protective Aluminum Anode Rodsl T&P Relief Valvel Low Restriction Brass Drain Valvel 5 Year Tank and Heat Exchanger Warrantyl AHRI Certified Water Heater Ratings
l Stand-by Heat Loss Is Less than 1/2°F per Hour (ASHRAE 90.1b Current Standard)
32,00030,00040,00040,00040,00050,00040,00040,00050,00040,00076,00085,000
5873114
SW-65C-5SW-80C-5SW-120C-5
2224
281/4
591/459
621/2
59 1/8483/858
59 3/850
603/459 5/8493/4581/2603/4633/46811/16
531/8527/8553/4
60593/4631/4
273300422
473/4473/4483/4
A
Floorto FlueConn.
C
Floor toT&P
Conn.
A
Floor toHeater
Top
B
JacketDia.
InputBTU/Hr.
GallonCapacity
ModelNumber
D
Floor toWaterConn.
53/853/863/8
E
Floor toExchanger
Outlet
F
Floor toExchanger
Inlet
111/2111/2111/2
G
Floor to Aquastat
Approx.Shipping
Weight (lbs)
ModelNumber 140°F 115°F
DOE Water Heater Performance
SW-65C-5SW-80C-5SW-120C-5
140°F 115°F
Maximum FirstHour Rating
(Gal.) @
534546583
820834871
ApproximateBoiler OutputNeeded for
Rating (BTU/Hr.)
Approximate BoilerOutput Needed
For Ratings(BTU/Hr.)
420,000420,000420,000
55,00055,00055,00055,000
ModelNumber
AHRI Water Heater Ratings
SW-65C-5SW-80C-5SW-120C-5
140°F 115°FFirst HourDelivery
405415445
ContinuousDraw Rating
@ 135°F(Gal./Hr.)
Approximate BoilerOutput Needed
For Ratings(BTU/Hr.)
370370370
HeatSource
Flow Rate(Gal./Min.)
14.014.014.0
HeatReq.Rate
(BTU/Hr.)245,000245,000245,000
StandbyHeat Loss(°F/Hr.)
0.70.60.4
55,00055,00055,00055,000Note: Pressure Drop across commercial models is 2.3
ft w.c. at 12 gpm for 200°F Boiler Supply.Note: These certified ratings were obtained with a heat source output rate and flow rate as specified and a 180°F boiler water supply temperature. Other results will be obtained under different conditions.
PowerStor Series® Single-Wall Indirect ModelsDIMENSIONS IN INCHES
page 152
page 153
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofM-3-ST80R5
B
A
FRONT REAR
DC
EF
GH
J
B
A
FRONT REAR
DC
EF
GH
J
CommercialJacketed Storage Tank Models
154/155
l Vitraglas® Liningl Optional ASME Construction Availablel 2" Non-CFC Foam Insulationl Water Connections—2" NPT true
dielectric fittings (M-3-ST120R5A and M-3-ST200R5A Have 21⁄2" Connections)
l Rear Connection—2" NPT Spud allows for rear water connection (M-3-ST120R5 and M-3-ST120R5A only)
l Hand Hole Cleanout (M-3-ST120R5 Has Optional Hand Hole Cleanout)
l Two Magnesium Anode Rodsl Steel Tankl 1" Side T&P Valve Openingl 3/4" NPT Aquastat Connectionl Low Restriction Brass Drain Valve
32,00030,00040,00040,00040,00050,00040,00040,00050,00040,00076,00085,000
8080119119200
M-3-ST80R5M-3-ST80R5A*M-3-ST120R5M-3-ST120R5A*M-3-ST200R5A*
2424282832
583/4583/4621/2621/277
59 1/8483/858
59 3/850
603/459 5/8493/4581/2603/4633/46811/16
521/2521/2553/4553/466
593/4593/4631/2631/278
192278312366633
91/491/491/291/2111/4
A
Floorto FlueConn.
C
Floor toT&P Valve
A
Floor toHeater
Top
B
JacketDia.
InputBTU/Hr.
GallonCapacity
ModelNumber
D
Floor toHot Water
Conn.
——91/291/2—
J
Floor toRear Water
Conn.
2(F&T)2(F&T)
2(F&T), 2(R)2 1/2(F&T), 2(R)
2 1/2(F&T)
WaterConn.Size†
141/4141/4141/2141/2161/4
E
Floor to Aquastat
Top Circ. Conn.
F
Floor to Bottom
Circ. Conn.
43/443/455
63/4
G
Floor toDrain Valve
71/471/4—71/291/4
H
Floor toHand Hole Cleanout
Approx.Shipping
Weight (lbs)
HOT OUTLET
HOT OUTLET
COLD INLET
COLD INLET
COLD INLET
SHUTOFFVALVE
SHUTOFFVALVE
SHUTOFFVALVE
CHECKVALVECHECK
VALVE
T & PT & P
T & P
T & PT & P
T & P
THERMOSTAT THERMOSTAT AQUASTAT
RECIRCULATINGLOOP
ALL BRONZECIRCULATOR ALL BRONZE
CIRCULATORALL BRONZECIRCULATOR
HH
C
BOILERTANKLESSCOIL
RECIRCULATINGLOOP
ALL BRONZECIRCULATOR
ALL BRONZECIRCULATOR
AQUASTATAQUASTAT
HOT OUTLET
* Meets ASME Code† (F) = Front water connections (R) = Rear water connections (T) = Top water connections
Jacketed Storage Tank ModelsDIMENSIONS IN INCHES
page 154
page 155
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Photo ofNV310JG5A
CommercialLarge Volume Jacketed Storage Tank Models
156/157
l Vertical or Horizontal Constructionl Water Connections—Two female 3" NPT fittings are located on the front for
ease of service and installation l ASME Constructionl Available with Vitraglas® Lining, Double Vitraglas® Lining, Epoxy Lining, or
Stainless Steel Tankl Hydrojet® HC—Optionall 2" High Density Insulationl Protective Magnesium Anode Rod(s)l ASME Tested and Certified to 125 psil Designed for Storage of Potable Water up to 180°Fl 5 Year Tank Warranty
A
C
B
Factory Options Include:• Manway (12" by 16")• Hand Hole (4" by 6")• Saddles
• Extra Tappings (1"- 4") Sizes must be specified when ordering
• Flanged Connections (3"-10")• Stainless Steel Construction• 150 psi (add suffix -5)• Hydrojet® HC (add suffix -1)
Manway inspection port is provided as standard equipment on epoxy lining. Options must be specified when ordering
page 156
page 157
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
175210240280285310320340360415435453465
N†175J*5AN†210J*5AN†240J*5AN†280J*5AN†285J*5AN†310J*5AN†320J*5AN†340J*5AN†360J*5AN†415J*5AN†435J*5A N†453J*5AN†465J*5A
718393107808611993981108989122
438493539603667710658760796881917942967
843108111471410169022292749
34343434404034404040464640
B
JacketDia.
30363642484848
Bare TankDia.
Actual U.S.Capacity
Gal.
193229260303318344340375397449486504502
Nominal U.S.Capacity
Gal.Model
NumberVert.
Height
677989103768211589941068588118
Horiz.Length
A
191/2191/2191/2191/22121
191/2212121
221/2221/221
191/22121
221/2242424
C
Floor to Inlet
21/221/221/221/221/221/221/221/221/221/233
21/2
Hot WaterOutlet Conn.
Approx. ShippingWeight (lbs)
@125 PSI
CommercialLarge Volume Jacketed Storage Tank Models
158/159
Vertical and Horizontal ModelsDIMENSIONS IN INCHES
500505515575580645675720765790840875104012451530
N†500J*5AN†505J*5AN†515J*5AN†575J*5AN†580J*5AN†645J*5AN†675J*5AN†720J*5AN†765J*5AN†790J*5AN†840J*5AN†875J*5AN†1040J*5AN†1245J*5AN†1530J*5A
8110113411392125104137116147128107149124148
117610171053111713101217145613171602140017481776200333263541
843108111471410169022292749
524640465246524652465258526464
B
JacketDia.
30363642484848
Bare TankDia.
Actual U.S.Capacity
Gal.
572558555630658702752774846846940981112813951689
Nominal U.S.Capacity
Gal.Model
NumberVert.
Height
779713010988121100133112143124103145120144
Horiz.Length
A
24221/221
221/224
221/224
221/224
221/224
271/2242927
191/22121
221/2242424
C
Floor to Inlet
33
21/2333333333333
Hot WaterOutlet Conn.
Approx. ShippingWeight (lbs)
@125 PSI
* = Tank Lining/ConstructionG = Vitraglas®
D = Double Vitraglas®
E = EpoxyS = Stainless Steel Example of full model number when ordering (NV240JG5A)
† = Tank OrientationV = VertcalH = HorizontalSaddles required for horizontal models.Use Bare Tank Diameter for saddle sizes.
Ten Year Warranty with Double Vitraglas® LiningOne Year Warranty with Epoxy Lining
Vertical and Horizontal ModelsDIMENSIONS IN INCHES
page 158
page 159
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
CommercialLarge Volume Unjacketed Storage Tank Models
160/161
l ASME Constructionl Available with Vitraglas® Lining, Double Vitraglas® Lining, Epoxy Lining, or Stainless Steel Tankl Hydrojet® HC—Optionall Magnesium Anode Rod(s)—For protection and longer service lifel ASME Tested and Certified to 125 psil Red Oxide Primer—Completely covers exterior of tankl 6" Skirt Height (Vertical Tank) Allows for Easier Access to Areas Under the Tankl Lifting Lugsl Designed for Storage of Potable Water up to 180°Fl 5 Year Tank Warranty
A
C
B
E
E
Factory Options Include:• Manway (12" by 16")• Hand Hole (4" by 6")• Saddles
• Extra Tappings (1"- 4") Sizes must be specified when ordering
• Flanged Connections (3"-10")• Stainless Steel construction• 150 psi (add suffix -5)• Hydrojet® HC (add suffix -1)
Manway inspection port is provided as standard equipment on epoxy lining. Options must be specified when ordering
page 160
page 161
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
175210240280285310320340360415435453465500505515575580
N†175N*5AN†210N*5AN†240N*5AN†280N*5AN†285N*5AN†310N*5AN†320N*5AN†340N*5AN†360N*5AN†415N*5AN†435N*5AN†453N*5AN†465N*5AN†500N*5AN†505N*5AN†515N*5AN†575N*5AN†580N*5A
677989103768211589941068588118779713010988
3033473834335505274765695596716958057439288748158631045
843108111471410169022292749
303030303636303636364242364842364248
B
JacketDia.
30363642484848
Bare TankDia.
Actual U.S.Capacity
Gal.
193229260303318344340375397449486504502572558555630658
Nominal U.S.Capacity
Gal.Model
NumberVert.
Height
63758599457811185901028151114735112610584
Horiz.Length
A
171/2171/2171/2171/21919
171/2191919
201/2201/21922
201/219
201/222
191/22121
221/2242424
CFloor
to Return Conn.
21/221/221/221/221/221/221/221/221/221/233333
21/233
DHot Water
OutletConn.
111111111111111111
E
DrainValve
Approx. ShippingWeight (lbs)
@125 PSI
CommercialLarge Volume Unjacketed Storage Tank Models
162/163
Vertical and Horizontal ModelsMeet or exceed ASHRAE 90.1b (current standard)DIMENSIONS IN INCHES
64567572076579084010401340182021052395270031153530404541205695
N†645N*5AN†675N*5AN†720N*5AN†765N*5AN†790N*5AN†840N*5AN†1040N*5AN†1340N*5AN†1820N*5AN†2105N*5AN†2395N*5AN†2700N*5AN†3115N*5AN†3530N*5AN†4050N*5AN†4120N*5AN†5695N*5A
121100133112143124145153168192216174198222192256262
9471173103113011101142816522182311035163922385143384825600955167994
843108111471410169022292749
4248424842484854606060727272847284
JacketDia.
30363642484848
Bare TankDia.
Actual U.S.Capacity
Gal.70275277484684694011281457198322762570296133843807446244066141
Nominal U.S.Capacity
Gal.Model
NumberVert.
Height1179612910813912014114716818621016819221693250256
Horiz.Length
A B C D E
201/222
201/222
201/22222
251/2272727303030333033
191/22121
221/2242424
Floorto Return
Conn.33333333333333333
Hot WaterOutletConn.
1111111
11/211/211/211/211/211/211/211/211/211/2
DrainValve
Approx. ShippingWeight (lbs)
@125 PSI
Example of full model number when ordering (NV175NG5A)
* = Tank Lining/ConstructionG = Vitraglas®
D = Double Vitraglas®
E = EpoxyS = Stainless Steel
† = Tank OrientationV = VertcalH = HorizontalSaddles required for horizontal models.Use Bare Tank Diameter for saddle sizes.
Ten Year Warranty with Double Vitraglas® LiningOne Year Warranty with Epoxy Lining
Vertical and Horizontal ModelsDIMENSIONS IN INCHES
page 162
page 163
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
CommercialLarge Volume Vertical Topcoat Storage Tank Models
164/165
l ASME constructionl Bradford White tanks with sprayed-on rigid insulation with acrylic topcoat exceeds ASHRAE 90.1
requirements with 2.25" of high-density polyurethane foam with an “R” value of R-16. SPF meets requirements for California Title 24. Bradford White spray foam insulation has the best fire spread rating with a class I foam with less than a 25-flame spread rating suitable for boiler room applications.
l The 100% acrylic topcoat is formulated for applications over spray polyurethane foam and is designed to withstand extreme weather and a full range of environmental conditions.
l The two component polyurethane foam is applied at ambient temperatures, directly to the vessel in the desired thickness. The 2-coat topcoat is then applied from a high-pressure spray gun and allowed to dry between applications.
l Alternative for insulated and steel jacketl Any tank size or shape can be insulatedl Field repairable
A
C
B
E
E
Spray Polyurethane Foam: Specific Gravity: 1.17 – 1.19Viscosity: 800 – 1300Density: @ 2” 2.10 – 2.35 @ 4” 1.88 – 1.99Closed Cell Content: >90%K-Factor, initial: 0.155 – 0.170Permeance: 2.91 (perms) 2.99 (perm inch)Dimensional Stability: +3.3 to +8.2 - Dry Age 28 days (158°F, Dry) -0.37 to –0.96 – Freeze 14 day (-20°F)Flame Spread: 25 - ASTM E-84Smoke Development: 450R Value: 7.2/ inch Max. Thickness: 4"
Acrylic Coating: Topcoat: 2 coats white, 25 milsTexture: SmoothGrade: Spray or RollBase: 100% AcrylicSolids by weight: 66% (+/-3) Solids by volume: 55% (+/-3)Weight per gallon: 11.65 (+/-.2)Tensile Strength: 300 psi (+/-25)Elongation: 260% (+/-25)Durometer hardness: 62 Shore A (+/-2)Tear Resistance: 85 lbs/ in.Permeance: 11 U.S. Perms @ 20 milsViscosity: 110 K.U. (+/-8)Codes/ Approvals: Energy Star, ICC, UL, ASTM D6083Reflectivity: New 85%, Aged 78%Emmisivity: .89
page 164
page 165
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
175210240280285310320340360415435465500515575580645
N†175T*5AN†210T*5AN†240T*5AN†280T*5AN†285T*5AN†310T*5AN†320T*5AN†340T*5AN†360T*5AN†415T*5AN†435T*5AN†465T*5AN†500T*5AN†515T*5AN†575T*5AN†580T*5AN†645T*5A
69819110576841179196108871207913211190123
3033473834335505274765695596716957439288158631045947
843108111471410169022292749
3535353541413541354147415341475347
B
JacketDia.
30363642484848
Bare TankDia.
Actual U.S.Capacity
Gal.193229260303318344340375397449486502572555630658702
Nominal U.S.Capacity
Gal.Model
NumberVert.
Height65778710145801138792104831167512810786119
Horiz.Length
A
171/2171/2171/2171/21919
171/2191919
201/2192219
201/222
201/2
191/22121
221/2242424
CFloor
to Return Conn.
21/221/221/221/221/221/221/221/221/221/2333
21/2333
DHot Water
OutletConn.
11111111111111111
E
DrainValve
Approx. ShippingWeight (lbs)
@125 PSI
CommercialLarge Volume Vertical Topcoat Storage Tank Models
166/167
Vertical and Horizontal Energy Saver ModelsDIMENSIONS IN INCHES
67572076579084010401340182023953115353041205695
N†675T*5AN†720T*5AN†765T*5AN†790T*5AN†840T*5AN†1040T*5AN†1340T*5AN†1820T*5AN†2395T*5AN†3115T*5AN†3530T*5AN†4120T*5AN†5695T*5A
102135114145126147153168216198222256262
1173103113011101142816522182311039224338482555167994
843108111471410169022292749
53475347535359656577777789
B
JacketDia.
30363642484848
Bare TankDia.
Actual U.S.Capacity
Gal.
75277484684694011281457198325703384380744066141
Nominal U.S.Capacity
Gal.Model
NumberVert.
Height
98131110141122143147168210192216250256
Horiz.Length
A
22201/222
201/22222
251/2272730303033
191/22121
221/2242424
CFloor
to Return Conn.
3333333333333
DHot Water
OutletConn.
111111
11/211/211/211/211/211/211/2
E
DrainValve
Approx. ShippingWeight (lbs)
@125 PSI
* = Tank Lining/ConstructionG = Vitraglas®
D = Double Vitraglas®
E = EpoxyS = Stainless Steel
† = Tank OrientationV = VertcalH = HorizontalSaddles required for horizontal models.Use Bare Tank Diameter for saddle sizes.
Example of full model number when ordering (NV240TG5A)Note: Please be advised that all tank sizes are available for this topcoat process.
Factory Options Include:• Manway (12" by 16")• Hand Hole (4" by 6")• Saddles
• Extra Tappings (1"- 4") Sizes must be specified when ordering
• Flanged Connections (3"-10")• Stainless Steel construction• 150 psi (add suffix -5)• Hydrojet® HC (add suffix -1)
Manway inspection port is provided as standard equipment on epoxy lining. Options must be specified when ordering
Ten Year Warranty with Double Vitraglas® LiningOne Year Warranty with Epoxy Lining
Vertical and Horizontal ModelsDIMENSIONS IN INCHES
page 166
page 167
Bradford White Product Pocket Catalog - 2016
FPC-0516© 2016, Bradford White Corporation. All Rights Reserved.
Committed to American Manufacturing, Wholesale Distribution, and Professional Installation.
www.bradfordwhite.com
Warranty Information 168/169
Some states do not allow limitations on warranties. See copy of the Warranty included with the heater. *Heat Exchanger Only **10 year parts warranty on warranty upgrade kit models only. †Heater Body Element Assembly.
Limited TankWarranty
Residential Gas ModelsAtmospheric Vent High EF Models ............................................................. 6 or 10 Year 6 or 10 Year**Atmospheric Vent Damper Models ............................................................. 6 or 10 Year 6 or 10 Year**Residential High EF Models........................................................................ 6 or 10 Year 6 or 10 Year**Residential High Performance Models ........................................................ 6 Year 6 YearResidential TTW® High Performance Models .............................................. 6 Year 6 YearResidential Extra Recovery Models ............................................................ 6 or 10 Year 6 or 10 Year**Residential Upright Models ........................................................................ 6 or 10 Year 6 or 10 Year**Residential Power Vent Models .................................................................. 6 or 10 Year 6 or 10 Year**Residential Power Direct Vent Models ........................................................ 6 or 10 Year 6 or 10 Year**Residential Direct Vent Models .................................................................. 6 or 10 Year 6 or 10 Year**Residential Ultra Low NOx Models ............................................................. 6 or 10 Year 6 or 10 Year**Residential eF Series® Models ................................................................... 6 or 10 Year 6 or 10 Year**Residential Manufactured Home Models .................................................... 6 or 10 Year 6 YearResidential Infiniti Tankless Models ........................................................... 12 Year* 5 YearResidential Heat Pump ModelsResidential AeroTherm™ Heat Pump Models .............................................. 10 Year 10 YearResidential Electric ModelsResidential High Efficiency, Upright, Lowboy Models ................................. 6 or 10 Year 6 or 10 Year**Residential Utility, Wall Hung Models ......................................................... 6 or 10 Year 6 or 10 Year**Residential Kwickshot® Models .................................................................. 10 Year† 1 YearSolar ModelsResidential Solar Models ........................................................................... 6 or 10 Year 6 YearResidential Hydronic/Space HeatingResidential Combi1™ Models ..................................................................... 10 Year 6 YearResidential Combi2™ Models ..................................................................... 10 Year 6 YearResidential Indirect ModelsResidential PowerStor Series® Model ......................................................... Limited Lifetime 6 YearResidential PowerStor2 Series® Models ..................................................... Limited Lifetime 6 YearResidential PowerStor Series® SS Models .................................................. Limited Lifetime 6 YearResidential Storage TankResidential AST Models ............................................................................. 6 Year 6 Year
Commercial Gas ModelsLight Duty Commercial High Performance Models ................................... 3 year 1 YearLight Duty Commercial TTW® High Performance Models ......................... 3 year 1 YearLight Duty Commercial Upright Models .................................................... 3 year 1 YearLight Duty Commercial Power Vent Models ............................................. 3 year 1 YearLight Duty Commercial Power Direct Vent Models ................................... 3 year 1 YearLight Duty Commercial Direct Vent Models .............................................. 3 year 1 YearLight Duty Commercial Ultra Low NOx Models ......................................... 3 year 1 YearCommercial Flue Damper Models ............................................................ 3 year 1 YearCommercial Induced Draft Models ........................................................... 3 year 1 YearCommercial Millivolt Models .................................................................... 3 year 1 YearCommercial eF Series® Ultra High Efficiency Models ............................... 3 year 1 YearCommercial Ultra Low NOx Models .......................................................... 3 year 1 YearCommercial Electric ModelsLight Duty Commercial Upright, Lowboy Models ...................................... 3 year 1 YearLight Duty Commercial Utility, Wall Hung Models ..................................... 3 year 1 YearCommercial Medium Duty Models ........................................................... 3 year 1 YearCommercial Surface Mount, Immersion Models ....................................... 3 year 1 YearCommercial ASME Models ....................................................................... 3 year 1 YearCommercial Brute Models........................................................................ 3 year 1 YearCommercial Indirect-FiredCommercial PowerStor® Models .............................................................. 5 year 1 YearCommercial Storage TankCommercial Jacketed Models .................................................................. 5 year 1 YearCommercial Bare Glass Coated Models ................................................... 5 year 1 YearCommercial Jacketed Large Volume Models............................................ 5 year 1 YearCommercial UnJacketed Large Volume Models ....................................... 5 year 1 YearCommercial Top Coat Large Volume Models ............................................ 5 year 1 Year
Limited PartsWarranty
Limited TankWarranty
Limited PartsWarranty
S = 1998 T = 1999 W = 2000 X = 2001 Y = 2002
Z = 2003 A = 2004 B = 2005 C = 2006 D = 2007
E = 2008 F = 2009 G = 2010 H = 2011 J = 2012
K = 2013L = 2014M = 2015N = 2016
K = 1993 L = 1994 M = 1995N = 1996 P = 1997
841/2841/2841/2731/2731/2731/2731/2731/2841/2841/2841/2841/2841/2
493/4 / 563/8 383/4
493/4 / 551/450 / 565/841 / 471/4511/2 / 5850 / 567/8
401/2 50 / 553/4501/2 / 58
33595/16
Tank Type Serial Number IdentificationFIRST LETTER - YEAR OF MANUFACTURE
A = JANUARYB = FEBRUARYC = MARCHD = APRIL
Example:FC12345678 = MARCH, 2009 ProductionNA12345678 = JANUARY, 1996 Production
Bradford White uses a 20-year letter designation rotation in serial numbers. Therefore, please be aware that water heaters manufactured 20 years apart will have the same serial number “letter year” designation.(i.e. A = 2004 and 1984).
E = MAYF = JUNEG = JULYH = AUGUST
J = SEPTEMBERK = OCTOBERL = NOVEMBERM = DECEMBER
SECOND LETTER - MONTH OF MANUFACTURE
page 168
page 169