product manual - standing seam ii - roof covering
TRANSCRIPT
Product Manual - Standing Seam II - Roof Covering
RC01A/EA, Reinforcing Seam Clamp InstallationRC01/EA, Detail at SidelapRC02/SA, Reinforced Panel Clip Attachment DetailRC03/SA, Panel to Clip Fastening Base Accessory AttachmentRC04A/EA, Reinforcing Seam Clamp Mid-Span of Purlins DetailRC04/EA, Reinforcing Seam Clamp DetailRC06/SA, Roof Panel EndlapRC07/SA, Panel Lap DetailRC17/EA, Typical Clip Attachment to PurlinRC36/EA, Standing Seam II Seaming ApplicationsRC61/EA, Basic Parts and PiecesRC62/EA, Standing Seam II Erection ToolsRC63/EA, Panel Marking and NotchingRC64/SA, Sequence of Roof Panel ErectionRC65/EA, Standing Seam II Duckbill Vise GripsRC66/EA, Clamping Detail at EndlapRC67/EA, Installation of Panel ClipRC68/EA, Standing Seam II Seaming MachineRC69/EA, Standing Seam MirrorRC76/EA, Standing Seam II Deseamer
3/9/2018
RODUCT ANUALSTANDING SEAM ROOF PANEL
P M
Issued 9/28/2016
Reinforcing Seam Clamp Installation
Standing Seam II
RC01A/EA
To Section Index
Download the DWG file by clicking here.
RODUCT ANUALP M
Issued 9/28/2016
Detail at Sidelap
Standing Seam II
RC01/EA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Revised: 03.31.21 (MR2021.04)
Reinforced Panel Clip Attachment Detail
Standing Seam II
RC02/SA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Issued 9/28/2016
Panel to Clip Fastening Base Accessory Attachment
Standing Seam II
RC03/SA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Issued 9/28/2016
Reinforcing Seam Clamp Mid-Span of Purlins Detail
Standing Seam II Roof
RC04A/EA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Issued 9/28/2016
Reinforcing Seam Clamp Detail
Standing Seam II Roof
RC04/EA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Revised: 03.05.21 (MR2021.03)
Roof Panel Endlap
Standing Seam II
RC06/SA
To Section Index
Download the DWG file by clicking here.
TAPE MASTIC PAD
PURLIN
1'-0"±
STANDING SEAM
ROOF PANEL ENDLAP
PANEL CLIP
LOWER PANEL
RC06
SA
INSULATION
LAP STIFFENER
CAULK END OF PANEL SEAM 6"
SSLS-1
NOTE:
BE CLAMPED TOGETHER.(SEE APPROPRIATE CLAMPING DETAILS)
PRIOR TO INSTALLING LAP FASTENERS, PANELS MUST
UPPER PANEL
6"
ROOF TRIM FASTENER(S)H1030
1 1/2 TP
RC07SA
SAFETY PRECAUTION:DO NOT STEP ON PANELS UNTILFULLY SECURED WITH FASTENERS.
3"
3"
STRUCTURAL FASTENER
H1020 (H1025 w/INSULATION OVER 6")
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Revised: 03.05.21 (MR2021.03)
Panel Lap Detail
Standing Seam II
RC07/SA
To Section Index
Download the DWG file by clicking here.
PANEL LAP DETAIL
THE LOWER AND UPPER PANEL NOTCHES WILL BUTT TOGETHER TO FORM A CONTINUOUS SEAM. RELAX THE MIDDLE OF THEOVER EXISTING INSTALLED PANEL. PULL MIDDLE OF UPPER PANEL UP AND SLIDE 3" NOTCH UNDER LOWER PANEL MALE SEAM. IS COVERED. INSTALL THE UPPER PANEL BY LAPPING THE LOWER PANEL 6" AND ROLLING/SETTING UPPER PANEL FEMALE SEAM SSCK-1 (BUTYL LAP CAULK) TO INNER FACE OF BOTH MALE AND FEMALE SEAMS, MAKING SURE THAT BACK EDGE OF MALE NOTCHSTANDING SEAM LAP MASTIC ACROSS THE WIDTH OF THE PANEL BEGINNING AND ENDING AT THE VERTICAL SEAMS. APPLY UPPER PANEL, INSTALL THE LAP STIFFENER, SSLS-1 AS SHOWN ABOVE. THEN PLACE PRECUT LENGTH OF SPECIAL 1 1/2" X 1/8"
CLEANER BEFORE MASTIC APPLICATION.
ALL AREAS ON ALUMINUM COATED PANELS THAT REQUIRE MASTIC SHOULD BE WIPED CLEAN WITH A MILD ALL PURPOSE DETERGENT
NOTCHED TO ACCEPT PANEL LAP. THIS LAP WILL OCCUR APPROXIMATELY 12 INCHES ABOVE A PURLIN. PRIOR TO SETTING THE
WHEN ENDLAPS ARE REQUIRED THE UPPER 3 INCHES OF THE LOWER PANEL SEAM AND LOWER 3" OF THE UPPER PANEL SEAM ARE
DIMPLE
EAVE
STANDING SEAM PANEL
STANDING SEAM CLIP
SSCK-1BUTYL CAULK
TAPE MASTIC PAD1 1/2 TP
CAULK END OF PANEL SEAM 6"
LAP STIFFENER
SSCK-1BUTYL CAULK
CAULK END OFPANEL SEAM 6"
SURFACE. DO NOT STEP ON PANELS UNTIL FULLY SECURED
WITH FASTENERS.
DO NOT STEP ON RIB OF PANEL. ALWAYS STEP ON FLAT
SAFETY PRECAUTION
STANDING SEAM PANEL
RC07 SASTANDING SEAM
ROOF TRIM FASTENER TYP.H1030
SSLS-1
UPPER AND LOWER PANELNOTCHES BUTTED TOGETHER
3"
3"
3"
3"
UPPER AND LOWER PANELNOTCHES BUTTED TOGETHER
UPPER PANEL ONTO PREVIOUSLY INSTALLED TAPE MASTIC AND CLAMP PANEL ENDLAP PER INSTRUCTIONS. NOW SECURE THE LAP WITH H1030 ROOF FASTENERS INSTALLED AT THE PRE-DIMPLED LOCATIONS WHILE CLAMPS ARE STILL IN PLACE. DONOT REMOVE CLAMPS UNTIL ALL REQUIRED FASTENERS ARE INSTALLED.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Revised: 03.05.21 (MR2021.03)
Typical Clip Attachment to Purlin
Standing Seam II
RC17/EA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM IIPANEL
PANEL CLIP
PURLIN
STANDING SEAM II
TYPICAL CLIP ATTACHMENT TO PURLIN
H1020 (H1025 w/INSULATION OVER 6")STRUCTURAL FASTENER(S)
RC17
EA
(2) PER CLIP
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Issued 9/28/2016
Standing Seam II Seaming Applications
RC36/EA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Revised: 03.05.21 (MR2021.03)
Basic Parts and Pieces
Standing Seam II
RC61/EA
To Section Index
Download the DWG file by clicking here.
SAFETY PRECAUTION:ALWAYS WEAR GLOVES WHEN
HANDLING MATERIALS.
METAL OUTSIDE CLOSURE
SSMOCMETAL EAVE CLOSURE
EA
RC61BASIC PARTS AND PIECES
STANDING SEAM II PANEL CLIP
STANDING SEAM II
SSMC-I
THERMAL BLOCK
SSPC-1 W/O THERMAL BLOCKS
UNDER NO CIRCUMSTANCES SHOULD STANDING SEAM II OR 360 BE USED WITHOUT BLANKETIN HIGH WINDS IF INSULATION IS NOT USED. STANDING SEAM II AND 360 ARE NO DIFFERENT.STANDING SEAM PANELS IN GENERAL ARE KNOWN FOR THEIR TENDENCY TO RUMBLE
INSULATION BETWEEN THE PANEL AND THE PURLIN/BAR JOIST.
STANDING SEAMSTANDING SEAM
SSPC-2TW/ TB1T THERMAL BLOCKS
TB1T
Note:Factory Mutual jobs (FM Rating) mayrequire additional or different fastenersand clips.
*
IF REQ'D, USE REINFORCED PANEL CLIP (SSCH)
IN CONJUNCTION WITH SSPC-_ IN DESIGNATEDAREAS.
**
**
**
FOR USE AT UNINSULATED ROOFS
1/2" x 2 1/2" x 50'-0" EPS, FOAM SPACER TAPE
50'-0" ROLL
STANDING SEAM LAP STIFFENER
SSLS-1
FASTENERSSECONDARY MATERIAL
(2) H1070 (H1075 w/INSULATION OVER 6")11 GA. - 1/2"
16 GA. - 12 GA. (2) H1020 (H1025 w/INSULATION OVER 6")
THICKNESS
CLIP ATTACHMENT
ROOF FASTENERH1030
*
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Issued 9/28/2016
Standing Seam II Erection Tools
RC62/EA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Issued 9/28/2016
Panel Marking and Notching
Standing Seam II
RC63/EA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Issued 9/28/2016
Sequence of Roof Panel Erection
Standing Seam II
RC64/SA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Issued 9/28/2016
Standing Seam II Duckbill Vise Grips
RC65/EA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Issued 9/28/2016
Clamping Detail at Endlap
Standing Seam II
RC66/EA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Revised: 03.05.21 (MR2021.03)
Installation of Panel Clip
Standing Seam II
RC67/EA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Issued 9/28/2016
Standing Seam II Seaming Machine
RC68/EA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Issued 9/28/2016
Standing Seam Mirror
RC69/EA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL
RODUCT ANUALP M
Issued 9/28/2016
Standing Seam II Deseamer
RC76/EA
To Section Index
Download the DWG file by clicking here.
STANDING SEAM ROOF PANEL