product innovations - hensel-electric.de 9500 kf 5000 g kf 9505 kf 5050 g kf 5500 kf 5000 b present...
TRANSCRIPT
2 3
dK Cable Junction Boxes “weatherproof” for outdoor installation (harsh environment and/or outdoor)
• from 1.5 up to 50 mm²
• degree of protection IP 66/67
• VdE-tested in accordance with IEC 60670-22
The evolution of the original!The evolution of the original!
DK Cable Junction Boxes “Weatherproof” for Outdoor Installation
Step 1:
For outdoor
installation
Various conductor cross sections and conductor types
All terminals with 2 clam-ping units per pole
High-position terminals with more space for wiring
Different terminal positions and fastening options
External brackets for fastening are always included
The evolution of the original continues.Count on more to come!
Reference table: Cable junction boxes “weatherproof” old-new
Present types
New types
KF 9020 KF 0200 G
KF 9025KF 0202 GKF 0402 G
KF 5020 KD 5020
KF 0200 B
KF 5025KD 5025
KF 0202 BKF 0402 B
KF 9040 KF 0400 G
KF 9045KF 0404 GKF 0604 G
KF 5040KD 5040
KF 0400 B
KF 5045KD 5045
KF 0404 BKF 0604 B
KF 9060 KF 0600 G
KF 9065KF 0606 GKF 1006 G
KF 5060KD 5060
KF 0600 B
KF 5065KD 5065
KF 0606 BKF 1006 B
KF 9100 KF 1000 G
Present types
New types
KF 9105KF 1010 GKF 1610 G
KF 5100KD 5100
KF 1000 B
KF 5105KD 5105
KF 1010 BKF 1610 B
KF 9250 KF 2500 G
KF 9255 KF 2525 G
KF 5250KD 5250
KF 2500 B
KF 5255 KD 5255
KF 2525 B
KF 9350 KF 3500 G
KF 9355 KF 3535 G
KF 5350KD 5350
KF 3500 B
KF 5355KD 5355
KF 3535 B
KF 9500 KF 5000 G
KF 9505 KF 5050 G
KF 5500 KF 5000 B
Present types
New types
KF 5505 KF 5050 B
KF 8020 KF 0200 H
KF 4020KD 4020
KF 0200 C
KF 8040 KF 0400 H
KF 4040KD 4040
KF 0400 C
KF 8060 KF 0600 H
KF 4060KD 4060
KF 0600 C
KF 8100 KF 1000 H
KF 4100KD 4100
KF 1000 C
KF 8250 KF 2500 H
KF 4250KD 4250
KF 2500 C
KF 8350 KF 3500 H
KF 4350KD 4350
KF 3500 C
KF 8500 KF 5000 H
KF 4500 KF 5000 C
Closes quickly by a quarter turn - closed position is visible
Multi-level knockouts for cable glands in different sizes
Cable entry also possible from the rear side
Burning behaviour in glow wire test 960 °C, high impact with-stand IK 09 (10 joule)
Eight enclosure sizes in grey and black.
Terminals prevent damage of conductors, also for flexible conductors without ferrule
5
Safe power supply in any weathers!
KV Small-type Distribution Boards
KV Small distribution boards are big in the safe and economical power supply in outdoor installation and in commercial and industrial applications. Safe through highest material quality.
Conforming to standards with Hensel expertise.
4
KV PC 9103 3 modules: 1 x 3 x 18 mm 1 row knockouts: top and bottom 2x M20 each mit PE/N Klemme
KV PC 9104 4,5 modules: 1 x 4,5 x 18 mm 1 row knockouts: top and bottom 1x M32/25 und 2x M20 each with PE/N terminal
KV PC 9106 6 modules: 1 x 6 x 18 mm 1 row knockouts: top and bottom 1x M32/25 und 2x M25/20 each with PE/N terminal
KV PC 9109 9 modules: 1 x 9 x 18 mm 1 row knockouts: top and bottom 1x M32/25 und 4x M25/20 each with PE/N terminal
KV PC 9112 12 modules: 1 x 12 x 18 mm 1 row cable entry via integrated elastic membranes with PE/N terminal N separable for various potentials
KV PC 9224 24 modules: 3 x 12 x 18 mm 2 rows cable entry via integrated elastic membranes with PE/N terminal N separable for various potentials
KV PC 9336 36 modules: 3 x 12 x 18 mm 3 rows cable entry via integrated elastic membranes with PE/N terminal N separable for various potentials
KV PC 9448 48 modules: 4 x 12 x 18 mm 4 rows cable entry via integrated elastic membranes with PE/N terminal N separable for various potentials
“Weatherproof” KV Small-type distribution boards up to 63 A• 3 up to 48 modules
• degree of protection IP 65, protection class II,
• made from polycarbonate
• for dIN-rail mounted devices up to 63 A according to dIN 43880
• operation possible by unskilled persons
6 7
Specialist close to working places!
Additional information, as rated current of a circuit and the number of circuits, which is now required for the construction of switchgear assemblies by desig-ners and manufacturers, is listed to each product.
Product presentation in media has changed as well!
ENYSTAR
Design fast, simply, more cleverwww. .eu
distribution Boards up to 250 Awith door, intended to be operated by ordinary persons (dBo) according to IEC 61439-3
• combinable enclosure system
• degree of protection IP 66
• made from polycarbonate
• protection class II,
Installation and ambient conditions
Operation and maintenance
Connection to the electric network
Electrical circuits and consumers
BLACK-BOX Specification with the 4 interfaces for the rating of power switchgear assemblies
Combinable enclosure system, insulation-enclosed, degree of protection, IP 66,
for the assembly of distribution boards up to 250 A intended to be operated by ordinary persons (DBO) according to IEC 61439-3The requirements of all installed electrical functions demonstrate compliance with the applicable require-ments of IEC 61439-3.
Inc and RDF must be specified in the documentation.
Interfaces according to IEC 61439-3The designer specifies a switchgear assembly by defining the interface parameters as BLACK-BOX. Based on these interface specifications the manufacturer of a switchgear assembly has to rate and define the structure of the assembly.
Operation areas for electrical unskilled persons are quick and easy to reach via a manually opening.
Devices to which only electrical skilled persons may have access for operation, shall be installed in separate areas, which can be opened only with a tool.
Key locking prevents un-authorized opening of the door
Manually opening where unskilled persons have to operate devices
Standard fasteners for slot screwdriver and triangle (optional square lock and double-bit)
Multikey
new
new
8 9
Mi Distribution Boards
Design fast, simply, more cleverwww. .eu
Operation and maintenance
Connection to the electric network
Installation and ambient conditions
Electrical circuits and consumers
BLACK-BOX Specification with the 4 interfaces for the rating of power switchgear assemblies
Combinable enclosure system, insulation-
enclosed, degree of protection, IP 65
for the assembly of power switchgear and controlgear assemblies (PSC) according to IEC 61439-2.The requirements of all installed electrical func-tions demonstrate compliance with the applica-ble requirements of IEC 61439-2.
Inc and RDF must be specified in the documentation.
Interfaces according to IEC 61439-2The designer specifies a switchgear assembly by defining the interface parameters as BLACK-BOX. Based on these interface specifications the manufacturer of a switchgear assembly has to rate and define the structure of the assembly.
Safe, especially when conditions are rough and difficult!
Mi Power distribution Board up to 630 Aas power switchgear and controlgear assembly (PSC)
according to IEC 61439-2
• combinable enclosure system
• degree of protection IP 65
• made from polycarbonate
• protection class II,
Mi 0600installation dimensions 575 x 425 x 146 mm
Mi 1684 with PE+NMi 1683 without PE+N2 x 28 x 18 mm and 2 x 12 x 18 mm
Mi 6632 3xHRC 00, 250 A Mi 6634 3xHRC 00, 400 A Mi 6636 3xHRC 00, 630 A
Mi 6642 4xHRC, 250 A Mi 6644 4xHRC 00, 400 A Mi 6646 4xHRC 00, 630 A
Mi 6652 250 A Mi 6655 400 AMi 6656 630 A
Mi 7665 630 A, 3-pole + PE+Nswitch disconnector
Mi 0601Installation dimensions 575 x 425 x 146 mm
new
8
6
4
150
300 600
300
450
600
3
2
1
150
150
1
new
Additional information, as rated current of a circuit and the number of circuits, which is now required for the construction of switchgear assemblies by designers and manufacturers, is listed to each product.
Product presentation in media has changed as well!
new
Due to an enlarged terminal compartment directly in the housing, some electrical functions can be installed more economical. An additional enclosure for wiring is not necessary.
new Enclosure size 6 (600x450 mm)
10
Energy Management Solutions, Ready-for-connection for Power Distribution Boards
Energy management - Both a challenge and an opportunity for electrical installers!
Energy management solutions, ready to integrate into power distribution boardsFor energy management according to
dIN EN ISo 50001
11
Introduction of an energy management system will be a requirement placed upon most companies. New power switchgear assemblies should be equipped with measuring devices. Most of the already existing power switchgear assemblies can be retrofitted.
This will open up a new field of activity for electrical installers and therefore the opportunity, as a competent partner, to support a company along the way to achieving transparent and reliable energy management.
The advantages of ENYLOGIC products:
intelligent functional enclosures for measuring equipment and data storage
ready-to-connect electrical functions integrated in Mi distribution boards
components which are perfectly matched with each other and guaranteed function of the whole system
many years of experience in integration of intelligent measuring equipment into switchgear assemblies up to 5000 A
the usual well-known quality of the Hensel brand
Products
for adding equipment to existing Mi distribution boards to achieve uniform measurement of electrical energy values
for retrofitting already installed switchgear assemblies for power distribution for the purposes of measured value acquisition and transmission
to gather and jointly transmit the measured energy values into a control system via TCP/IP
The basic requirement
for a transparent energy
management system is a
continuous and reliable
measurement of energy.
Only when this data is
available it is possible
to identify the points of
consumption, to analyse
these and to optimise
them in a next step.
new
12 13
www.enysun.eu
PV generator junction boxes with protective devices for all applications
For connection and parallel opera-tion of generators in the public low-voltage grid with coupling switch and power grid
and system protection in accordance with the german standard VDE-AR-N 4105 in accordance with IEC 61439-2
Safe product solutions for photovoltaic plants conforming to standards
Photovoltaic solutions: pre-fabricated and testedIndividual solutions for grid connection of generating plants into networks of local power supply companies with measuring with power management and disconnect unit according to the German Renewable Energy Sources Act (EEG), application guideline VDE-AR-N 4105 and requirements imposed by the grid operator
Connection of a sub-distribution board: 5-pole
1 Connection of the local power supply company: 4-pole
2 Connection of the power generation unit: 5-pole
3
Power management in levels and trans-mission of the actual infeed according to EEG
4
Measuring power supply of genera-ting unit5Measuring power consumption of local power supply companies6
Disconnect unit according to application guideline VDE-AR-N 41057
1
2
3
4
5
6
7
PV solar inverter collectors take into account the thermal load by generating plants
Service and Digital Media
www.hensel-electric.dewww.hensel-electric.de
Our download portal offers you a variety
of catalogues and information material.
Downloads
Service Digitale Medien
Configurator ENYGUIDE supports project engineering f
for ENYSTAR and Mi distribution boards systems.
The intuitively usable 3D design tool
ENYGUIDE supports electricians, engineers and electrical wholesalers with the
planning, design and order of ENYSTAR and Mi distribution board systems.
ENYGUIDE
Products with technical details Services Company Contact References News Noticing list High-speed search of products On-line purchase order forms for catalogues and service offers
Download of documents
Internet
The electronic browse cata-
logue with search function
and PDF export!
Scroll through the online catalog
and take advantage of the search
function that allows you to quickly
find the information you want.
Try it out!
Browse cataloge
14 15
Social Media
Hensel News on facebook!
facebook.com/henselelectric
Follow us on twitter!
twitter.com/henselelectric
Hensel Videos on YouTube!
youtube.com/henselelectric
Discover our installation videos,
product benefits and manuals for our products
in concise, informative spots on youtube.com/henselelectric
Videos
Learn more about our company
in our video portrait!
Seminars and Trainings at the factoryHensel supports you to be always one
step ahead
In your region Hensel and its Agents
can organize local trainings and semi-
nars, where the main technical features
and highlights are shown, discussed,
explained and sometimes also mounted.
Trade fairs
Participation in trade fairs and exhibitions is part of successful customer care.
In addition to the Light + Building show in Frankfurt, the regional electrotechnical
trade shows in Germany and abroad are very important to both electrical special-
ists and ourselves.
We look forward to your visit!
InfoMobil
Mobile exhibitionsWe are also pleased to inform you about our system solutions and new products
on site in our mobile exhibitions.
Trade fairs / Mobile Exhibitions
new
Hensel webpages for your
Smartphone
You can visit the Hensel website with
your Smartphone. Via a mobile Web
browser, you can open the website.
The mobile catalogue has been created
specifically for smartphones. All informa-
tion will be shown on your Smartphone
compact and easy to match the screen
size.
Mobile catalogue
98 17 0881 07.14/3/11
Gustav Hensel GmbH & Co. KGIndustrial Electrical Power Distribution Systems
AltenhundemGustav-Hensel-Straße 6D-57368 LennestadtGermanyP.O. Box 1461D-57344 Lennestadt, Germany