product guide - central states mfg, inc. · 2020-03-11 · central states manufacturing, inc....

12
5V Product Guide HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES GUID_PROD_5V_190715.1 D C 24" COVERAGE ½" Copyright © 2020, Central States Manufacturing, Inc., All Rights Reserved.

Upload: others

Post on 11-Jun-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Product Guide - Central States Mfg, Inc. · 2020-03-11 · CENTRAL STATES MANUFACTURING, INC. Effective 2 /2020 • Information subject to change 3 NOTICE: The application and detail

5V ™Product Guide

HELPFUL INFORMATION ON PANELS, TRIMS, GUTTERS AND ACCESSORIES

GUID_PROD_5V_190715.1D C

24" COVERAGE

½"

Copyright © 2020, Central States Manufacturing, Inc., All Rights Reserved.

Page 2: Product Guide - Central States Mfg, Inc. · 2020-03-11 · CENTRAL STATES MANUFACTURING, INC. Effective 2 /2020 • Information subject to change 3 NOTICE: The application and detail

We promise to improve your businessby accurately providing quality productsright when you need them. Every time.

Visit our website for more product information, testing, installation guides, energy ratings, warranties, photo gallery, color visualizer, and more.

centralstatesmfg.com

Page 3: Product Guide - Central States Mfg, Inc. · 2020-03-11 · CENTRAL STATES MANUFACTURING, INC. Effective 2 /2020 • Information subject to change 3 NOTICE: The application and detail

C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .E f f e c t i v e 2 / 2 0 2 0 • I n f o r m a t i o n s u b j e c t t o c h a n g e 3

NOTICE: The application and detail drawings in this manual are strictly for illustration purposes and may not be applicable to all building designs or product installations. Projects should conform to local building codes. Central States Manufacturing is not responsible for the performance of the material if it is not installed correctly.

Information contained in this booklet was in effect at the time of publication and is subject to change without notice.

Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Panel Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Fastener Spacing, Delivery . . . . . . . . . . . . . . . . . . . .5Storage / Handling/ Cutting / Drilling. . . . . . . . . .6Trim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

INDEXInformation in the catalog may vary by plant location.Please call your salesperson to verify product availability.

Page 4: Product Guide - Central States Mfg, Inc. · 2020-03-11 · CENTRAL STATES MANUFACTURING, INC. Effective 2 /2020 • Information subject to change 3 NOTICE: The application and detail

C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .E f f e c t i v e 2 / 2 0 2 0 • I n f o r m a t i o n s u b j e c t t o c h a n g e 4

24" COVERAGE½"

5V is available in 26 ga. and 29ga bare Galvalume, or 29 ga. bare galvanized G90. Bare (non-painted) panels from Central States have an acrylic coating which eliminates using oils during manufacturing, and eliminates fingerprinting and foot marking during installation. Bare Galvalume features a 25-year AZ55 substrate warranty, but is not warranted for uniformity in appearance, whether it be color, sheen, or spangle. If the project requires a uniform appearance, please choose a painted product of a different profile.

The minimum roof slope for 5V is 3:12.

No load table available. Install 5V over solid decking with 30 lb. felt paper or equivalent.

5V™

WARRANTIESWARRANTIESWarranties are available in paper format and downloadable from our website. After the job is complete, fill out a warranty with your contractor/installer details and the Central States order number. Give the warranty to the building owner to keep for their records. Optional warranty registration is available online.

Learn more at centralstatesmfg.com/warranties

Page 5: Product Guide - Central States Mfg, Inc. · 2020-03-11 · CENTRAL STATES MANUFACTURING, INC. Effective 2 /2020 • Information subject to change 3 NOTICE: The application and detail

C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .E f f e c t i v e 2 / 2 0 2 0 • I n f o r m a t i o n s u b j e c t t o c h a n g e 5

DELIVERIES

FASTENER SPACING

Deliveries will be made using a 65' tractor/trailer weighing approximately 80,000 lbs. It is imperative that all delivery locations be accessible by a vehicle of this size. Our drivers have the authority to refuse delivery to any location they see as unsafe or inaccessible. The customer is responsible for any charges incurred

if truck is detained for any reason. The customer is responsible for unloading all trucks. Any damage that occurs at this point is the customer’s responsibility. There must be equipment or at least 3 people available to unload the truck.

PANEL CODESPANEL GAUGE TYPE CODE5V 26 Gauge Galvalume® 5V26GL5V 29 Gauge Galvalume® 5V29GL5V 29 Gauge Galvanized G90 5V29Z

Galvalume® is a registered trademark of BIEC International, Inc..

Fastener pattern at panel termination (Eave, endlap, valley)

Fastener pattern at interior of panel

Page 6: Product Guide - Central States Mfg, Inc. · 2020-03-11 · CENTRAL STATES MANUFACTURING, INC. Effective 2 /2020 • Information subject to change 3 NOTICE: The application and detail

C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .E f f e c t i v e 2 / 2 0 2 0 • I n f o r m a t i o n s u b j e c t t o c h a n g e 6

STORAGEGalvalume steel sheets have a good service life when exposed to normal weather conditions. However, to protect the appearance of panels and trims from damage, there are a few simple precautions that can be taken. The steel sheets are subject to stain when water sits upon, or becomes trapped between, the sheets. If the galvalume sheets are to be stored for any period of time, they should be stored only in a dry place, preferably under a roof. Stand panels on end and fan them out at the bottom to provide air circulation and moisture run off. If space does not allow this, the panels should be separated, blocked off of the floor at least 12 inches to allow air flow, and stored at an incline to encourage drainage. The panels should then be covered, yet still have good air flow through the sheets to prevent condensation. Do not use a plastic cover, as this may cause the panels to sweat or condensation to occur.

Failure to follow these steps may result in wet storage stains and premature rusting. The manufacturers warranty will be void at this time, and the manufacturer will not be responsible.

HANDLINGWhen unloading panels, extreme caution must be employed. Care needs to be used when unloading panels with a forklift. Panel edges and underside may become damaged if the forklift driver does not use caution. Once at the job site, care must be taken in order to protect the surface.

When unbundling the panels, never drag them across the surface of one another. This may cause scratches across the underneath panels. It is recommended that the panels be “rolled” off the top of the bundle to prevent scratching. Never lift panels by the ends, instead lift the panels longitudinally and carry vertically.

Panel edges are very sharp, therefore, safety equipment should be worn by all workers handling the material.

CUTTINGA portable field shear is the ideal method for cutting panels. Nibblers or a power shear may also be used. Although we do not recommend it, if you decide to cut with a saw, it is very important that the panels be turned upside down during cutting so that hot shavings do not come in contact with the surface. Make sure all adjacent panels are covered so that shavings are not imbedded in these panels. If metal shavings become imbedded in the surface, they will quickly rust. To avoid this, panels should be thoroughly wiped of all filings on both sides of the panel. Failure to comply with the recommended cutting procedures releases the manufacturer of any responsibility.

DRILLINGPanels should not be drilled while stacked. This will cause shavings that will become imbedded in the surface.

CARE AND HANDLING

Shavings created by saw cutting or drilling may cause the panel to rust and will void warranties in affected areas.CAUTION

Page 7: Product Guide - Central States Mfg, Inc. · 2020-03-11 · CENTRAL STATES MANUFACTURING, INC. Effective 2 /2020 • Information subject to change 3 NOTICE: The application and detail

C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .E f f e c t i v e 2 / 2 0 2 0 • I n f o r m a t i o n s u b j e c t t o c h a n g e 7

PART # LENGTH GIRTH NOTES

RIDGE / HIPRRCP(color) 10'2" 17" Specify pitch

pitch

MINI RESIDENTIAL RAKE MINIRRT(color) 10'2" 8"

RESIDENTIAL RAKE

RRT(color) 10'2" 10.75"

RESIDENTIAL DRIP EDGERDC(color) 10'2" 9.5" Specify pitch 90° pitch if not specified

pitch

VT261º open hem

VALLEY

VT1(color) 10'2" 19.75" Specify pitchVT2(color) 10'2" 20.75" Specify pitch

pitch

pitch

VT1

21 2

1 22

1 2

1 2

All angles are 90° or 45° unless otherwise noted. All trims are 29 gauge unless otherwise specified.Use color code Z for galvanized and GL for Galvalume.

TRIMS

Page 8: Product Guide - Central States Mfg, Inc. · 2020-03-11 · CENTRAL STATES MANUFACTURING, INC. Effective 2 /2020 • Information subject to change 3 NOTICE: The application and detail

C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .E f f e c t i v e 2 / 2 0 2 0 • I n f o r m a t i o n s u b j e c t t o c h a n g e 8

PART # LENGTH GIRTH NOTES

SEA10P(color) 10'2" 9.5" Specify pitch

TRIM

5VCL(color) 10'2" 3"

pitch

SHORT EAVE TRIM

LONG EAVE TRIM LEA10P(color) 10'2" 9.5" Specify pitch

PART # LENGTH NOTES

pitch

5V CONTINUOUS CLEAT

5V ZEE CLOSURE

1” 1”

3/4”

5VZC(color) 10'2" 2.75"

21/2

1/2

All angles are 90° or 45° unless otherwise noted. All trims are 29 gauge unless otherwise specified.Use color code Z for galvanized and GL for Galvalume.

BOX GUTTER BG(color) 10'2" 17.25"

31/2”

4”

4”

1”

31/8”

3/4”

Page 9: Product Guide - Central States Mfg, Inc. · 2020-03-11 · CENTRAL STATES MANUFACTURING, INC. Effective 2 /2020 • Information subject to change 3 NOTICE: The application and detail

C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .E f f e c t i v e 2 / 2 0 2 0 • I n f o r m a t i o n s u b j e c t t o c h a n g e 9

CLOSURESCLOUT5V 24"CLIN5V 24"

PART # LENGTH

METAL/WOOD SCREW #10

1ZMW 1" 250 3000112ZMW 1 1/2" 250 25002ZMW 2" 250 2000212ZMW 2 1/2" 250 1500

1/4" head

PART # LENGTH #PER BAG #PER BOX

LAP SCREW #14 78ZLAP 7/8" 250 25005/16" head *order in increments of 250pc

*order in increments of 250pc

GEO(color) 10.3oz tube clear, grayMRSCLEAR 10.3oz tube clearMRS(color) 10.3oz tube all

SEALANT

LOW PROFILEPANCAKE HEAD SCREWS

SSR1WOOD 1" 250 5000

POP RIVET POP 100FOR FLASHING JOINTS 1/8" body diameter

INSIDE

OUTSIDE

ACCESSORIES

Page 10: Product Guide - Central States Mfg, Inc. · 2020-03-11 · CENTRAL STATES MANUFACTURING, INC. Effective 2 /2020 • Information subject to change 3 NOTICE: The application and detail

C E N T R A L S T A T E S M A N U F A C T U R I N G , I N C .E f f e c t i v e 7 / 2 0 1 9 • I n f o r m a t i o n s u b j e c t t o c h a n g e 10

NOTES

Page 11: Product Guide - Central States Mfg, Inc. · 2020-03-11 · CENTRAL STATES MANUFACTURING, INC. Effective 2 /2020 • Information subject to change 3 NOTICE: The application and detail
Page 12: Product Guide - Central States Mfg, Inc. · 2020-03-11 · CENTRAL STATES MANUFACTURING, INC. Effective 2 /2020 • Information subject to change 3 NOTICE: The application and detail

w w w.CentralStatesMfg.com