product flyers ... bulkheads and roller gates 17 round bottom bulkheads 19 segmented stopboards 21...

Download PRODUCT FLYERS ... BULKHEADS AND ROLLER GATES 17 ROUND BOTTOM BULKHEADS 19 SEGMENTED STOPBOARDS 21 LAYFLAT

If you can't read please download the document

Post on 14-Nov-2020

0 views

Category:

Documents

0 download

Embed Size (px)

TRANSCRIPT

  • www.awmawatercontrol.com.au

    P E N S T O C K S I S T O P B O A R D S I B U L K H E A D S I F L O O D G A T E S I S C R E E N S

    P R O D U C T F LY E R S

    www.awmawatercontrol.com.au

  • HEAD OFFICE

    www.awmawatercontrol.com.au

    Phone +61 3 5456 3331 Email info@awmawatercontrol.com.au 118 Roviras Road, PO Box 433, Cohuna Victoria 3568, Australia.

    Quality ISO 9001

    C O N T E N T S SPECIALISED WATER CONTROL GATES 3

    ULF PENSTOCKS 5

    TLF PENSTOCKS 7

    DLF PENSTOCKS 9

    DECANT GATES 11

    WLF PENSTOCKS 13

    STOPLOGS 15

    BULKHEADS AND ROLLER GATES 17

    ROUND BOTTOM BULKHEADS 19

    SEGMENTED STOPBOARDS 21

    LAYFLAT GATES 23

    SIDEWINDERS 25

    HEAD & DISCHARGE GATES 27

    COMBINATION GATES 29

    FLAP GATES 31

    RADIAL GATES 33

    SELF-REGULATING TIDAL GATES 35

    TRASH SCREENS 37

    CUSTOM FLOOD GATES 39

    DEMOUNTABLE FLOOD BARRIERS 41

    RETRACTABLE FLOOD BARRIERS 43

    CONCEALED FLOOD BARRIERS 45

    TILTING FLOOD BARRIERS 47

  • www.awmawatercontrol.com.au

    SPECIALISED WATER CONTROL GATES AWMA specialise in engineering one-off products for site specific water, effluent and odour control.

    FEATURES • Extremely high head pressure (proven up to 100 tonne) • Full perimeter sealing • Materials to withstand aggresive environments • Diverse size orfices • Accommodating short shut-down periods • Unique retrofit site requirements • Highly specified conditions • Where no civil works are allowed • Submerged installations • Integration into fully automated processes • Containment of dry, solid or gaseous mediums • Chemical containment • Underground (tunnelling or mining) applications • Low impact designs to minimise injury to ecological assets • Infrastructure with 100 year life expectancy • Low whole of life costs

    APPLICATIONS • AWMA develop, design, manufacture and install specialised control gates and

    associated automation systems for applications across all industry sectors.

  • HEAD OFFICE

    www.awmawatercontrol.com.au

    Phone +61 3 5456 3331 Email info@awmawatercontrol.com.au 118 Roviras Road, PO Box 433, Cohuna Victoria 3568, Australia.

    Quality ISO 9001

    DESIGN DESIGN SUPPORT • AWMA’s design team will provide full support to ensure the most appropriate solution is developed and specified during the preliminary design.

    SIZES • All of AWMA’s Water Control Systems are custom sized to ensure they meet specific site requirements.

    MATERIALS • AWMA select materials to meet a minimum design life of 25 years.

    Where required, AWMA can offer higher grade materials, coatings and protection systems to extend the design life to 100+ years.

    • Materials used in the construction of AWMA’s specialised gate range have a high corrosion resistance and can be operated for many years with minimal maintenance.

    SEALING • The seal performance of AWMA Water Control Gates exceed that required by the ‘Australian Technical Specification for Fabricated Water Control Infrastructure’.

    MAINTENANCE • AWMA’s gates typically have a minimum 25 year design life. • Minimal maintenance is required offering low ‘whole of life costs’.

    MANUFACTURE QUALITY • All fabrication is in accordance with the ‘Australian Technical Specification for Fabricated Water Control Infrastructure’.

    • All procedures are in accordance with AWMA’s accredited ISO 9001 Quality Management System to ensure each gate is manufactured to a high standard, tested and ready for trouble free operation post approved installation.

    INSTALLATION MOUNTING OPTIONS • Gate products are developed to meet specifications. • Early project involvement ensures development of the most appropriate gate product and specifications for the application.

    ACTUATION SYSTEMS • AWMA offer numerous options for operation including manual,

    mechanical, automated, hydraulic, pneumatic, powered or electrically actuated systems.

    • Staged upgrade programs are also available. OPERATION SYSTEMS • A range of options are available for control and operation of

    specialised gate systems: - Integration into new or existing SCADA systems optional. - Global, web based operating platforms for remote control and

    monitoring. - Solar, mains, pneumatic or hydraulically powered. - Variety of lifting mechanisms available, including AWMA’s self-

    engaging lifting frame. • Storage and transportation solutions available. • Associated systems include warning lights, water level indicators, automated message systems, reflective signage, video feeds and battery backups.

    COMMISSIONING DOCUMENTATION AND TRAINING • Detailed documentation on operation, testing procedures and maintenance will be provided with all AWMA flood defence systems.

    • Comprehensive on and/or off site training available.

    S P E C I A L I S E D WAT E R C O N T R O L G AT E S

  • www.awmawatercontrol.com.au

    U L F P E N S TO C K S AWMA’s ULF Penstock range consists of undershot regulating penstocks for flow regulation, diversion, level control or isolation. The ULF Penstocks are also known as Sluice Gates, Slide Gates, Sluice Valves, Stop Gates or Water Gates.

    FEATURES • Resilient seals on three sides of the aperture (for full perimeter sealing

    see the TLF Penstock and WLF Penstock). • Bi-directional sealing available. • Both rising and non-rising spindle configurations available. • Custom designed and fabricated to suit any size or shaped orifice.

    APPLICATIONS • The ULF Penstock range is commonly used for many applications across

    all industry sectors. • Undershot isolation and regulation. • Undershot regulation of open channel flow.

  • HEAD OFFICE

    www.awmawatercontrol.com.au

    Phone +61 3 5456 3331 Email info@awmawatercontrol.com.au 118 Roviras Road, PO Box 433, Cohuna Victoria 3568, Australia.

    Quality ISO 9001

    DESIGN DESIGN SUPPORT • AWMA’s design team will provide full support to ensure the most appropriate solution is developed and specified during the preliminary design.

    SIZES • All AWMA water control gates are custom sized to ensure they meet specific site and operational requirements.

    • Customisation reduces installation costs. MATERIALS • AWMA select materials to meet a minimum design life of 25 years.

    Where required, AWMA can offer higher grade materials, coatings and protection systems to extend the design life to 100+ years.

    • AWMA use ultra high molecular weight polyethylene (UHMWPE) for penstock door guides and/or wedges to provide maintenance free bearing surfaces.

    • Plasticised PVC or EPDM are used for the manufacture of seals. These materials offer superior endurance in wastewater and freshwater applications.

    • Materials used for penstock door and frames include marine grade aluminium and grades 304, 316, 2205 and 2507 stainless steel.

    • Materials used in the construction of the ULF Penstock range have a high corrosion resistance and can be operated for many years with minimal maintenance.

    SEALING • The sealing ability of this gate exceeds that required by the ‘Australian Technical Specification for Fabricated Water Control Infrastructure’.

    MAINTENANCE • The ULF Penstock range has a minimum 25 year design life. • Minimal maintenance is required offering low ‘whole of life costs’. • If required, all the wearing components can be changed, with ease,

    on site.

    MANUFACTURE QUALITY • All fabrication is in accordance with the ‘Australian Technical Specification for Fabricated Water Control Infrastructure’.

    • All stainless steel welding is continuous to avoid crevice corrosion. • All procedures are in accordance with AWMA’s accredited ISO 9001

    Quality Management System to ensure each gate is manufactured to a high standard, tested and ready for trouble free operation post approved installation.

    INSTALLATION MOUNTING OPTIONS • The ULF Penstocks are typically wall mounted. • The side frames can be face mounted or embedded. • The sill is available in a raised or flat sill configuration. • Mount to concrete headwalls, in a channel or within channel rebates. ACTUATION SYSTEMS • Choose from - Rising Spindle or - Non-Rising Spindle • Handwheel, electric, hydraulic or pneumatic actuator. • Portable 12VDC actuator and 240VAC actuator available. • Accepts portable petrol power actuator system. OPERATION SYSTEMS • Integration into new or existing SCADA systems optional. • Global, web based operating platforms for remote control and

    monitoring.

    COMMISSIONING DOCUMENTATION AND TRAINING • Detailed documentation on operation, testing procedures and

    maintenance will be provided with all AWMA water control solutions. • Comprehensive on and/or off site training available.

    U L F P E N S TO C K S

  • www.awmawatercontrol.com.au

    T L F P E N S TO C K S AWMA’s TLF Penstock range consists of an undershot gate with a full perimeter seal, providing flow isolation for fully submerged on or off seating applications.

    FEATURES • Resilient seals around all four sides of the aperture. • Excellent sealing for med-high head applications. • Bi-directional sealing optional. • Both rising and