Motion Analyzer 5.100 – Release Notes 1
Motion Analyzer 5.100 | Release Notes
Product Data Updates for Motion Analyzer 5.100
Incorporation of Medusa Cables
Shimpo Gearboxes added
Alpha TPA+ gearboxes added
Alpha CP gearboxes restored
HPK-B2510C motor added
Low voltage support added for PowerFlex 70 and PowerFlex 700.
This is for information purpose only. Low Voltage Motor Series is
not available for PowerFlex 70 and PowerFlex 700.
New Inertia unit “Kg-mm2” added
Brake rating has been updated for all Motors. Brake option and
inertia data has been updated for all HPK motors.
ENDAT associated Control System updates for Kinetix 6200 &
6500, Kinetix 300 and Kinetix 350 family.
Low HP Drives have been added for Powerflex 755 family
Motion Analyzer 5.100 – Release Notes 1
Other Changes in Motion Analyzer 5.100
1. Units handling error for amplifiers in Manual selection has been
corrected.
2. Life calculation for MPAI has been updated.
Known Limitations in Motion Analyzer 5.100
1. Motion Analyzer 5.100 does not correctly analyze the power supply for RPS shunt modules. Evaluation will produce an incorrect zero result.
Motion Analyzer 5.100 – Release Notes 1
New Feature Overview Motion Analyzer 5.000
New Welcome Screen
Professional revised workflow
Profile Editor Enhancements and Additional Index types
Motor and Drive selection assistants
Individual Axis Notes and System Notes
Common Operating Conditions
License Control
SolidWorks Interface Enhancements
New Product additions
Motion Analyzer 5.100 – Release Notes 1
New Feature Details
1. New Welcome Screen
a. New: Workflow selections
i. Professional – New work flow
ii. Classic – Classic Motion Analyzer work flow
iii. Just Quote – Select a Bill of Material for Kinetix
products
b. Open: Open files from your PC. Opens a file search window.
c. Recent: Displays a list of recently opened file to click on and
open.
Motion Analyzer 5.100 – Release Notes 1
2. Professional Revised Work Flow
a. New Work Flow steps
i. Load Type
ii. Motion Profile Design
iii. Mechanism Selection
iv. Transmission Selection
v. Motor Family Selection
vi. Drive Family Selection
vii. Search Solution
b. Progress Icon Bar
i. An Icon bar at the bottom of the screen indicates the
work flow progress for the axis being entered.
c. Super Review tab
i. Super Review tab displays all motion calculated
results in a tabular form for every Profile segment at
each point in the mechanical system.
3. Profile Editor Enhancements
a. Ability to switch axes while Profile Editor is open
b. Ability to Copy and Paste move profiles between Axes within
the Profile Editor
Motion Analyzer 5.100 – Release Notes 1
c. The value of Time (Master) at the cursor position of the
Profile Editor Graph is displayed in a new „Time‟ label. This
label can be used to view the Time (Master) value in MU (or
any other time unit).
d. The maximum and minimum velocity constraints of an Index
segment can be specified for an Index move. Motion
Analyzer will adjust the index segment to restrict the
maximum and minimum velocities to within the applied limits.
If the user entered limits cannot be supported an error
message will be displayed in Profile Editor.
Motion Analyzer 5.100 – Release Notes 1
4. Profile Editor – Additional Segment Types
a. Index 2 3 Poly (Parabolic)
i. This move type is not supported in RSLogix 5000
natively. Motion Analyzer Profile Editor is used to
build the cam, and then it can be exported to the
RSLogix 5000 Cam editor in a MATC or MAPC
instruction.
b. Index Adjusted Sine (Cycloidal)
i. This move type is not supported in RSLogix 5000
natively. Motion Analyzer Profile Editor is used to
build the cam, and then it can be exported to the
RSLogix 5000 Cam editor in a MATC or MAPC
Motion Analyzer 5.100 – Release Notes 1
instruction.
c. Index 4 5 6 7 Polynomial ( 7th order Polynomial)
i. This move type is not supported in RSLogix 5000
natively. Motion Analyzer Profile Editor is used to
build the cam, and then it can be exported to the
RSLogix 5000 Cam editor in a MATC or MAPC
instruction.
d. Index Modified Trapezoidal
i. This move type is not supported in RSLogix 5000
natively. Motion Analyzer Profile Editor is used to
build the cam, and then it can be exported to the
RSLogix 5000 Cam editor in a MATC or MAPC
instruction.
5. Motor Selection Assistant
a. Select from a family of motors that can supply the speed and
torque required for your application when using the
Professional work flow.
6. Drive Selection Assistant
Motion Analyzer 5.100 – Release Notes 1
a. Select from a family of Drives that are compatible with the
Motor Family selected when using the Professional
workflow.
7. Axis and System Notes
a. Ability to add Axis Notes to each axis in the Motion Analyzer
System file. This is in addition to the System Notes that are
available.
8. Common Operating Conditions
Motion Analyzer 5.100 – Release Notes 1
a. Common Operating Conditions
b. Individual operating conditions for L10 Life Calculations and
Power Supply Energy Estimate calculations have been
moved to a common location.
9. License Control
Motion Analyzer 5.100 – Release Notes 1
a. Registration has been implemented for the Full version of
Motion Analyzer 5.000. If you do not wish to register you will
be able to use Motion Analyzer 5.000 in a Lite version, which
has limited functionality.
b. Registration can be accomplished via Online registration or
Offline (email) registration.
10. My Preferred Database
a. Mark Standard Database name has been changed to My
Preferred Database. Use this to predefine motors and drives
that are searched through for a solution.
Motion Analyzer 5.100 – Release Notes 1
Motion Analyzer 5.100 – Release Notes 1
11. SolidWorks Interface Enhancements
a. SolidWorks Model must be open in SolidWorks when
launching Simulation tools from Motion Analyzer.
b. SolidWorks Motion Study must be set up when launching
Simulation tools – gravity, SolidWorks motors, velocity and
force/torque results plots, and any additional external forces
must be defined.
c. For single axis or independent axis of motion, enter data into
Motion Analyzer axis, selecting “From SolidWorks” as your
load type. In the axis, you may reverse your motion profiles
in order to drive velocity in the correct direction on the
model, and again if necessary to make the returned data
align with the original defined motion profile.
Motion Analyzer 5.100 – Release Notes 1
d. For interdependent axis of motion, you must define profile
data and launch the SolidWorks Simulation tool from the
System View page. You may reverse your motion profile in
order to drive velocity in the correct direction on the model.
Motion Analyzer 5.100 – Release Notes 1
New Product Details
1. Kinetix 3 Drive products
2. MPAI Heavy Duty Electric Cylinders
3. Support for Kinetix 6200_6500, Kinetix 300 families in „Just Quote‟
mode.
4. Support for RDD, MPM, LDC and LDL Motor series in „Just Quote‟.
5. Support for MPAI and MPMA Actuator Series in „Just Quote‟
Motion Analyzer 5.100 – Release Notes 1
Other Changes
1. Allen-Bradley Integrated Gearmotors have been removed. They have been replaced by Integrated Gearmotors that include Wittenstein / Alpha TPM+ Integrated Gearmotors.
2. Program name has been changed from EzSize.exe to MotionAnalyzer.exe
3. Linear motor magnet track selection has been enhanced.
4. Triangular move type added to the Press Roll Feed template.
5. Brake Selection for Electric Cylinders have been updated.
6. Brake Rating Utilization for Motor
Brake Rating Utilization bar graph is added to Motor solution page.
This utilization bar graph will show the brake utilization of a Motor. If
the Brake rating of the selected is not available in Motion Analyzer
database a warning triangle and a message tooltip is displayed in
Motion Analyzer.
Motion Analyzer 5.100 – Release Notes 1
7. Lossless Force Velocity curves for Stages and Electric Cylinders
For stages and electric cylinder, on Solution tab, the Force Velocity
curve for Gross data (without losses) and with losses is available in
the “Force – Velocity” tab and in “Additional Information” in the
Actuator tab respectively. We recommend that you ignore this
lossless data unless you have a specific reason to reference it, as
this lossless curve does not correlate with the actual performance
of these stages and cylinders.
Motion Analyzer 5.100 – Release Notes 1
Known Limitations
1. PowerFlex drives are not supported by Tuning Simulation or in Bill of
Materials in this release.
2. For application sizing, selection of IAM in Power Supply/Accessories View will be updated in Bill of Materials only after user visits the "Configure Axis BOM" tab of the first axis.
3. Kinetix 300 and Kinetix 3 Tuning Simulation is not supported in this
release.
4. Encompass partner products including Wittenstein/Alpha, Stober, and
Apex gearboxes and Elwood/Getty Explosion Rated motors are not
supported in the Bill of Materials.
5. Consecutive Logix Linear elements are not allowed to be imported into the
Logix Elements in Motion Analyzer Profile Editor.
6. CM222 motors are only available as 460 VAC in this release.
7. When analyzing interdependent axis of motion using the SolidWorks
Simulation tool from the System View page, you may not reverse the
returned data in order to make it align with the original data as you can
within an axis.
8. Stacked Stages (MPMA series) is not supported in Professional Mode.
9. On launching the product details catalog on a Windows 7 64 bit machine,
the product catalog is opened to the first page as opposed to the page
containing the details of the selected product.
10. In Professional size, it is recommended to select User defined Motor
series (My Series) independently. Selecting “My Series” along with other
Motor Series results in some know issues in voltage selection in the
subsequent Drive Page.
Motion Analyzer 5.100 – Release Notes 1
SolidWorks Requirements
Static Inertia Import – SolidWorks 2009 and above SolidWorks Simulation – SolidWorks 2009 with SolidWorks Motion add-in On a Windows 7 machine, SolidWorks must be launched as an administrator (CTRL+SHIFT+Right Click -> Run as Administrator option on the shortcut) so as Motion Analyzer connects to the correct instance of SolidWorks.
Motion Analyzer 5.100 – Release Notes 1
Motion Analyzer System Requirements
Installing Motion Analyzer 5.000 – The Setup program checks for the availability of the minimum requirement of disk space / OS / Display resolution, etc. before continuing.
List of various requirements is as follows: Operating System
The following operating systems are supported:
i. Windows 2000 Service Pack 4 Prerequisite: MDAC 2.8 Download link: http://msdn2.microsoft.com/hi-in/data/aa937730(en-us).aspx
ii. Windows XP Service Pack 2 (or greater) iii. Windows Vista (32 and 64 Bit) iv. Windows 7 (32 and 64 Bit) v. Do Not install on Windows 95
Processor
Pentium III Processor (or greater) is recommended.
RAM
Minimum 256 MB RAM is recommended.
Screen Resolution Supported Screen Resolution is 1024x768 (High color). Setup will check the current screen resolution and will provide a warning if screen resolution is less than 1024x768 pixels.
Browser
Browser should be IE5.5 or higher.
Disk Space Minimum disk space should be 330MB.
.NET Framework
Minimum .NET Framework required is 2.0. System requirements for .NET Framework 2.0 are present at following URL:
http://www.microsoft.com/downloads/details.aspx?familyid=0856eacb-4362-
4b0d-8edd-aab15c5e04f5&displaylang=en#Requirements