product data - dcne data... · 2021. 2. 25. · product data pg8maa/pg8jaa multipoise gas furnace...
TRANSCRIPT
Product Data
PG8MAA/PG8JAAMULTIPOISE GAS FURNACE
A10257
The Payne PG8MAA/JAA 80% AFUE Gas Furnaces feature4−way Multipoise design and through−the−furnace downflowventing. The PG8MAA/JAA furnaces are approved for use withnatural or propane gas, and the PG8JAA − Low NOx units aredesigned for California installations and meet 40 ng/J NOxemissions. Can be installed in air quality management districts witha 40 ng/J NOx emissions requirement.
STANDARD FEATURES� Four-position furnace: Upflow, Horizontal Right, Horizontal
Left, Downflow
� Electronic control centerAdjustable heating air temperature rise, LED diagnostics and selftest feature. Stores fault codes during power outages.
� Hot surface ignition (HSI)
� Cabinet air leakage less than 2.0% at 1.0 in. W.C. andcabinet air leakage less than 1.4% at 0.5 in. W.C. whentested in accordance with ASHRAE standard 193
2
MODEL NUMBER NOMENCLATURE1
BrandP
2Product
G
3Base Effy.
8
4Variation
M
5Motor
A
6Major Series
A
7 - 9Cooling Cap.
036
10 - 12Heating Cap.
070
13 - 14Minor Series
AA14
Variations| | | | | | | | | |
8 - 80 AFUEM - Multipoise
J - Low Nox
A - Std. /PSC
Brand
Product
Minor Series
Major Series
045 = 44,000 BTU070 = 66,000 BTU090 = 88,000 BTU110 = 110,000 BTU135 = 132,000 BTU
024 - 800 CFM030 - 1000 CFM036 - 1200 CFM042 - 1400 CFM048 - 1600 CFM054 - 1800 CFM060 - 2000 CFM 066 - 2200 CFM
A180214
For California Residents:For installation in SCAQMD only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to amitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com
DIMENSIONS
FURNACE SIZE
A CABINET
WIDTHIN (mm)
B OUTLETWIDTHIN (mm)
CTOP &
BOTTOM FLUECOLLAR IN (mm)
D BOTTOM INLET
WIDTHIN (mm)
VENTCONNECTION
SIZEIN (mm)
SHIP WTLB (KG)
024045 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 104 (47)
036045 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 107 (49)
024070 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 111 (50)
036070 14-3/16 (360) 12-9/16 (319) 9-5/16 (237) 12-11/16 (322) 4 (102) 115 (52)
048070** 17-1/2 (445) 15-7/8 (403) 11-9/16 (294) 16-1/8 (410) 4 (102) 126 (57)
042090 17-1/2 (445) 15-7/8 (403) 11-9/16 (294) 16-1/8 (410) 4 (102) 127 (58)
048090 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 140 (64)
060090** 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 146 (66)
036110 17-1/2 (445) 15-7/8 (403) 11-9/16 (294) 16-1/8 (410) 4 (102) 135 (61)
048110 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 146 (66)
066110 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102) 152 (69)
048135 21 (533) 19-3/8 (492) 13-5/16 (338) 19-1/2 (495) 4 (102)* 149 (68)
066135 24-1/2 (622) 22-7/8 (581) 15-1/16 (383) 23 (584) 4 (102)* 163 (74)
060155 24-1/2 (622) 22-7/8 (581) 15-1/16 (383) 23 (584) 4 (102)* 170 (77)
*135 and 155 size furnaces require a 5 or 6-in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation Instructions forcomplete installation requirements.
** Low NOx version not offered in this size.
3
DIMENSIONS
A180207
PG
8M
AA
/ J
AA
4
A10269
Always Ask For
Use of the AHRI Certified TM Mark indicates amanufacturer’s participation in the program. Forverification of certification for individual products,go to www.ahridirectory.org.
PG
8M
AA
/ J
AA
5
SPECIFICATIONS
UNIT SIZE 024045 036045 024070 036070 048070 042090 048090
RATINGS AND PERFORMANCE
Input Btuh*Non-weatherized ICS
PG8JAA Upflow; all PG8MAA 44,000 44,000 66,000 66,000 66,000 88,000 88,000
PG8JAA Downflow/Horizontal 42,000 42,000 63,000 63,000 63,000 84,000 84,000
Output Capacity(Btuh)†Non-weatherized ICS
PG8JAA Upflow; all PG8MAA 35,000 36,000 53,000 54,000 53,000 71,000 71,000
PG8JAA Downflow/Horizontal 34,000 34,000 51,000 51,000 51,000 68,000 68,000
AFUE† 80.0 80.0 80.0 80.0 80.0 80.0 80.0
Certified Temperature Rise Range °F (°C)30‐60
(17-33)20‐50
(11-28)40‐70
(22-39)30‐60
(17-33)25‐55
(14-30)40‐70
(22-39)30‐60
(17-33)
Certified External Static Pressure Heat/Cool 0.10/0.50 0.10/0.50 0.12/0.50 0.12/0.50 0.12/0.50 0.15/0.50 0.15/0.50
Airflow CFM‡Heating 865 1250 720 1195 1350 1300 1505
Cooling 835 1160 870 1200 1505 1385 1635
ELECTRICAL
Unit Volts-Hertz-Phase 115‐60‐1
Operating Voltage Range Min‐Max 104‐127
Maximum Unit Amps 5.2 7.2 5.1 7.2 9.5 8.6 10.0
Maximum Wire Length (Measure 1 Way in Ft (M)) 49 (14.9) 37 (11.2) 51 (15.5) 38 (11.5) 29 (8.8) 32 (9.7) 28 (8.5)
Minimum Wire Size 14
Maximum Fuse or Ckt Bkr Size (Amps)** 15
Transformer (24v) 40va
External Control Heating 12va
Power Available Cooling 35va
Air Conditioning Blower Relay Standard
CONTROLS
Limit Control SPST
Heating Blower Control Solid‐State Time Operation
Burners (Monoport) 2 2 3 3 3 4 4
Gas Connection Size 1/2‐in. NPT
GAS CONTROLS
Gas Valve (Redundant) White‐Rodgers
Min. inlet pressure (in. W.C.) 4.5 (Natural Gas)
Max. inlet pressure (in. W.C.) 13.6 (Natural Gas)
Ignition Device Hot Surface
BLOWER DATA
Direct‐Drive Motor HP (PSC) 1/5 1/3 1/5 1/3 1/2 1/3 1/2
Motor Full Load Amps 2.8 5.2 2.8 5.2 7.1 5.2 7.1
RPM (Nominal)‐Speeds 1075‐3 1075‐3 1075‐3 1075‐3 1075‐3 1075‐3 1075‐3
Blower Wheel Diameter x Width - In. (mm) 10 x 6(254 x152)
10 x 6(254 x152)
10 x 6(254 x152)
10 x 6(254 x152)
11 x 8(279 x203)
10 x 8(254 x203)
10 x 10(254 x254)
FILTER ARRANGEMENT External filter rack required
* Gas input ratings are certified for elevations to 2000 ft. (610 M). For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M)above sea level. In Canada, derate the unit 10 percent for elevations 2000 ft (610 M) to 4500 ft (1372 M) above sea level. Refer to National Fuel Gas CodeNFPA 54/ANSI Z223.1-2012 Table F.1 (d) or furnace installation instructions.
† Capacity in accordance with U.S. Government DOE test procedures.
‡ Airflow shown is for bottom only return‐air supply for the as‐shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. Afilter is required for each return‐air supply. An airflow reduction of up to 7 percent may occur when using the factory‐specified 4‐5/16 in. (110 mm) wide, highefficiency media filter.
** Time‐delay type is recommended.
ICS Isolated Combustion System
N/A Not applicable
PG
8M
AA
/ J
AA
6
SPECIFICATIONS continued
UNIT SIZE 060090 036110 048110 066110 048135 066135 060155
RATINGS AND PERFORMANCE
Input Btuh*Non-weatherized ICS
PG8JAA Upflow; all PG8MAA 88,000 110,000 110,000 110,000 132,000 132,000 154,000
PG8JAA Downflow/Horizontal 84,000 105,000 105,000 105,000 126,000 126,000 147,000
Output Capacity(Btuh)†Non-weatherized ICS
PG8JAA Upflow; all PG8MAA 71,000 89,000 89,000 89,000 107,000 107,000 125,000
PG8JAA Downflow/Horizontal 68,000 85,000 85,000 85,000 102,000 102,000 119,000
AFUE† 80.0 80.0 80.0 80.0 80.0 80.0 80.0
Certified Temperature Rise Range °F (°C)25‐55
(14-30)50‐80
(28-44)40‐70
(22-39)30‐60
(17-33)50‐80
(28-44)40‐70
(22-39)45‐75
(25-41)
Certified External Static Pressure Heat/Cool 0.15/0.50 0.20/0.50 0.20/0.50 0.20/0.50 0.20/0.50 0.20/0.50 0.20/0.50
Airflow CFM‡Heating 1900 1295 1515 1840 1480 1830 1790
Cooling 2025 1355 1655 2160 1710 2085 2215
ELECTRICAL
Unit Volts-Hertz-Phase 115‐60‐1
Operating Voltage Range Min‐Max 104‐127
Maximum Unit Amps 14.1 8.6 10.2 15.1 10.5 14.5 15.4
Maximum Wire Length (Measure 1 Way in Ft (M)) 31 (9.4) 32 (9.7) 27 (8.2) 29 (8.8) 27 (8.2) 30 (9.1) 29 (8.8)
Minimum Wire Size 12 14 12 14 12
Maximum Fuse or Ckt Bkr Size (Amps)** 20 15 20 15 20
Transformer (24v) 40va
External Control Heating 12va
Power Available Cooling 35va
Air Conditioning Blower Relay Standard
CONTROLS
Limit Control SPST
Heating Blower Control Solid‐State Time Operation
Burners (Monoport) 4 5 5 5 6 6 7
Gas Connection Size 1/2‐in. NPT
GAS CONTROLS
Gas Valve (Redundant) White‐Rodgers
Min. inlet pressure (in. W.C.) 4.5 (Natural Gas)
Max. inlet pressure (in. W.C.) 13.6 (Natural Gas)
Ignition Device Hot Surface
BLOWER DATA
Direct‐Drive Motor HP (PSC) 3/4 1/3 1/2 3/4 1/2 3/4 3/4
Motor Full Load Amps 11.8 5.2 7.1 11.8 7.1 11.8 11.8
RPM (Nominal)‐Speeds 1075‐3 1075‐3 1075‐3 1075‐3 1075‐3 1075‐3 1075‐3
Blower Wheel Diameter x Width - In. (mm) 11 x 11(279 x279)
10 x 8(254 x203)
10 x 10(254 x254)
11 x 11(279 x279)
10 x 10(254 x254)
11 x 11(279 x279)
11 x 11(279 x279)
FILTER ARRANGEMENT External filter rack required
* Gas input ratings are certified for elevations to 2000 ft. (610 M). For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M)above sea level. In Canada, derate the unit 10 percent for elevations 2000 ft (610 M) to 4500 ft (1372 M) above sea level. Refer to National Fuel Gas CodeNFPA 54/ANSI Z223.1-2012 Table F.1 (d) or furnace installation instructions.
† Capacity in accordance with U.S. Government DOE test procedures.
‡ Airflow shown is for bottom only return‐air supply for the as‐shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. Afilter is required for each return‐air supply. An airflow reduction of up to 7 percent may occur when using the factory‐specified 4‐5/16 in. (110 mm) wide, highefficiency media filter.
** Time‐delay type is recommended.
ICS Isolated Combustion System
N/A Not applicable
PG
8M
AA
/ J
AA
7
A02058
SEE NOTES: 1,2,4,7,8,9UPFLOW
SEE NOTES: 1,2,3,4,7,8,9UPFLOW
SEE NOTES: 1,2,4,5,7,8,9DOWNFLOW
A02059 A02061
SEE NOTES:1,2,3,4,5,7,8,9DOWNFLOW
SEE NOTES: 1,2,3,4,5,7,8,9DOWNFLOW
SEE NOTES: 1,2,4,5,6,7,8,9DOWNFLOW
A02060 A02063 A02062
Venting Notes1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas
Code (NFGC), ANSI Z223.1/NFPA 54.2. Immediately increase to 5‐in. (127 mm) vent connector outside furnace casing when 5‐in. (127 mm) vent connector
required, refer to Note 1.3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace,
except when accessory Downflow Vent Guard is used in downflow position.4. Type B vent where required, refer to Note 1.5. 4-in. (102 mm) single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit.6. Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration.7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing
and complete application details.8. Secure vent connector to furnace elbow with (2) corrosion‐resistant sheet metal screws, space approximately 180°
apart.9. Secure all other single wall vent connector joints with (3) corrosion‐resistant screws spaced approximately 120°
apart. Secure Type B vent connectors per vent connector manufacturer's recommendations.
PG
8M
AA
/ J
AA
8
SEE NOTES: 1,2,4,5,7,8,9HORIZONTAL RIGHT
A02068
SEE NOTES: 1,2,4,5,7,8,9HORIZONTAL RIGHT
A02070
SEE NOTES: 1,2,4,7,8,9HORIZONTAL RIGHT
A02069
SEE NOTES: 1,2,4,7,8,9HORIZONTAL LEFT
A02064
SEE NOTES: 1,2,4,5,7,8,9HORIZONTAL LEFT
A02065
SEE NOTES: 1,2,4,5,7,8,9HORIZONTAL LEFT
A02066
SEE NOTES: 1,2,4,5,7,8,9HORIZONTAL LEFT
A02067
PG
8M
AA
/ J
AA
9
ACCESSORIES
DESCRIPTION PART NO. 024045 036045 024070 036070 048070 042090 048090 060090 036110 048110 066110 048135 066135 060155
External Bottom Return Filter Rack
KGBFR0401B14 X X X X
KGBFR0501B17 X X X
KGBFR0601B21 X X X X X
KGBFR0701B24 X X
Unframed Filter, 3/4‐in. (19 mm)
KGAWF1306UFR X X X X X X X
KGAWF1406UFR X X X X X
KGAWF1506UFR X X
Flue Extension KGAFE0112UPH X X X X X X X X X X X X X X
Twinning Kit KGATW0601HSI X X X X X X X X X X X X X X
Combustible Floor Base KGASB0201ALL X X X X X X X X X X X X X X
Downflow Vent Guard KGBVG0101DFG X X X X X X X X X X X X X X
Vent Extension Kit KGAVE0101DNH X X X X X X X X X X X X X X
Chimney Adapter KitKGACA02014FC X X X X X X X X X X X
KGACA02015FC X X X
Natural‐to‐Propane Conversion Kit * KGBNP50011SP X X X X X X X X X X X X X X
Propane‐to‐Natural Conversion Kit KGBPN42011SP X X X X X X X X X X X X X X
Label Kit KGALB0301KIT X X X X X X X X X X X X X X
Gas Orifice
LH32DB207
See Installation Instructions for model, altitude, and heat value usages.
LH32DB202
LH32DB200
LH32DB205
LH32DB208
LH32DB078
LH32DB076
LH32DB203
LH32DB201
LH32DB206
LH32DB209
LH32DB210
* Factory authorized, field installed. Fuel conversion kits are CSA (formerly AGA/CGA) recognized.
X Accessory
PG
8M
AA
/ J
AA
10
AIR DELIVERY—CFM (With Filter)*
FURNACESIZE
RETURN-AIRINLET
SPEEDEXTERNAL STATIC PRESSURE (In. W.C.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
024045Bottom or
Side(s)
HighMed-HighMed-Low
1035865760
995830720
945790680
895745635
835690580
770625520
675545445
565440345
390250220
195195195
036045Bottom or
Side(s)
HighMed-HighMed-Low
144013601250
137513001210
130512401160
124011751100
116011151040
10701040965
975950885
870850790
730725670
560575520
024070Bottom or
Side(s)
HighMed-HighMed-Low
1030835725
1005815700
965790675
925755635
870710595
810660545
740590460
645480350
465325250
280205--
036070Bottom or
Side(s)
HighMed-HighMed-Low
142513201200
137512801175
132012401145
126512051105
120011401050
11251075990
1035995920
940905840
830790725
655620555
048070Bottom or
Side(s)
HighMed-HighMed-Low
175515501355
170015201340
163514751310
157014301280
150513751240
143513101190
135012401125
126011551060
11601070975
1055970890
042090Bottom or
Side(s)
HighMed-HighMed-Low
160514701310
157014451295
153514101265
146513801230
138513001195
128512201120
117511151025
1055990915
895830710
645600565
048090Bottom or
Side(s)
HighMed-HighMed-Low
194017401505
188017001505
180516501480
172015901440
163515251375
154014401300
142513351190
129011951045
10901010890
830820740
060090
Bottom Only
HighMed-HighMed-Low
240521701920
231021101875
222020401835
213019701780
202518951715
192017851630
179016751535
166015651420
153014201275
135012601135
Both Sides or 1Side & Bottom
HighMed-HighMed-Low
253022301895
245021701890
236521101845
227020501815
216519851755
206518901685
194017801600
180516601480
167015251350
150513601180
1Side Only
HighMed-HighMed-Low
247521051850
239521451860
230020701810
220020101770
209019401715
198518451650
186517351555
173016201445
158514751310
142513251150
036110Bottom or
Side(s)
HighMed-HighMed-Low
160014751315
155014351295
149013951265
142513351220
135512851155
126011851080
11351070985
990890810
785725675
530450440
048110Bottom or
Side(s)
HighMed-HighMed-Low
198017451530
191517101515
183516501470
175015601400
165514501310
149513401215
136512051095
11851090990
965865830
700605670
066110
Bottom Only
HighMed-HighMed-Low
248521351855
241521001840
234020601815
225520001775
216019301725
208018601675
195017651600
184016701510
172015551405
156514251290
Bottom Sidesor 1 Side & Bot
tom
HighMed-HighMed-Low
--21401855
--21001840
235520501815
228519901775
219019351725
209018651675
196517601600
185016701510
170515451405
153514101290
1Side Only
HighMed-HighMed-Low
24952030--
244020251735
237020001725
229019501695
220519051650
212018501595
201517501535
191016601455
177515551335
162514251230
* A filter is required for each return-air inlet. Airflow performance included 3/4-in. (19 mm) washable filter media such as contained in factory-authorized accessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 In. W.C. available external static pressure.
-- Indicates unstable operating conditions.
PG
8M
AA
/ J
AA
11
AIR DELIVERY—CFM (With Filter)* continued
FURNACESIZE
RETURN-AIRINLET
SPEEDEXTERNAL STATIC PRESSURE (In. W.C.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
048135Bottom or
Side(s)
HighMed-HighMed-Low
206517901480
200017551480
193017051480
183516401450
171015501380
159014651295
142012951160
123511451005
1025945855
835775670
066135
Bottom Only
HighMed-HighMed-Low
244521301860
236520801830
228020251800
219019601755
208518801705
198017951630
185016901530
170515501415
152014051280
135512551140
Bottom, Sidesor 1 Side & Bot
tom
HighMed-HighMed-Low
--21201860
--20751830
235519951800
228019701755
216019051725
206518351630
193017351530
180516451415
165515151280
146513251140
1 Side Only
HighMed-HighMed-Low
--20701860
--20151830
221519701800
213019351755
203018551725
192017651630
179516551530
167515501415
154014451280
138512651140
060155
Bottom Only
HighMed-HighMed-Low
246521151800
243020951790
237520551770
230520051735
221519401695
211018451640
200018201570
186516751465
171515251345
153013901225
Both Sides Or 1Side & Bottom
HighMed-HighMed-Low
--21551800
--21251790
237520751770
228520151735
218519351695
210518301640
199517801570
187016351465
172014851345
155513651225
1Side Only
HighMed-HighMed-Low
--21401800
--20851790
226020201770
218019501735
207018501695
197517451640
186516951570
174015451465
159514151345
144012901225
* A filter is required for each return-air inlet. Airflow performance included 3/4-in. (19 mm) washable filter media such as contained in factory-authorized accessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 In. W.C. available external static pressure.
-- Indicates unstable operating conditions.
�2018 Payne Heating & Cooling Systems � 7310 W. Morris St. � Indianapolis, IN 46231 . Edition Date: 09/18
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Catalog No: SS-PG8M-11