product catalogue 2021/22 innovative storage tank and
TRANSCRIPT
Product catalogue 2021/22Innovative storage tank and container solutionsValid from April 2021
Clever heat storage.
2 I Product catalogue 2021
Pressure and pressurized containers from 30 Litresmin. height 500 mmmin. diameter 300 mm
» Custom-made storage tanks "made in germany"
In batch and individual unit production! Our know-how enables us to respond to customer requests in a highly individual manner. Just ask us, we will look for solutions together.
Detailed information from page 78 upwards.
Buffer storage tanks until 25.000 Litres max. height â 6.000 mmmax. diameter 2.400 mm3 bar / 6 bar
enamelled domestic water storage tanks until 6.000 Litresmax. height â 6.000 mmmax. diameter 1.250 mm10 bar
enamelled domestic water storage tanks until 5.000 Litresmax. height 3.200 mmmax. diameter 1.500 mm3 bar / 6 bar / 8 bar
enamelled domestic water storage tanks until 3.200 Litresmax. height 3.200 mmmax. diameter 1.200 mm10 bar
www.huch.com I 3
Overview of our storage tanks - the right solution for every heating system 04
New in the catalogue 06
Solar storage tanks ESS-PU Solar storage tank, rigid foam 10
SSH Solar storage tank 12
SSH-Plus Solar storage tank 14
Domestic water storage tanks EBS-PU Domestic water storage tank, rigid foam 18
BS Domestic water storage tank 20
HLS-Plus High-performance storage tank 22
PSB Buffer storage tank 24
HSO Domestic water storage tank, rigid foam 26
WWS-TS Domestic water storage tank, vertical, rigid foam 28
Buffer storage tanks SPSX Stratified buffer storage tank with stratification system 32
SPSX-G / SPSX-2G Stratified buffer storage tank with bare-tube heat exchangers 34
PSX-ECO Buffer storage tank 36
PSX-G-ECO Buffer storage tank with bare-tube heat exchangers 38
PS-BHKW Buffer storage tank 40
GPS Buffer storage tank up to 10.000 Liter 42
Systems for Huch storage tanks
PSFW /-G Buffer storage tank for FRIWA Fresh 46
FRIWA Fresh water stations Fresh Easy 30 / Fresh Hydro 40 48
Combined storage tanks WKS-WP Heat pump storage tank with corrugated stainless steel pipe (6,5 mÂČ) 54
WKS Combined storage tank with corrugated stainless steel pipe (5 mÂČ) 58
Stainless steel storage tank HSS Strainless steel solar storage tank 62
HBS Strainless steel domestic water storage tank 64
HPS Strainless steel buffer storage tank 66
Pressure vessel DWK Pressurised water storage, vertical / horizontal design 72
DLB Compressed ait tank, vertical / horizontal design 74
Other tanks AG Expansion vessels 76
FK Filter boiler 77
Custom-made tanks Buffer-, domestic water- , cold water buffer storage tanks (KWP) Calculation assist 78
Accessories Huch Accessories for Storage tanks and vessels 84
Quality features / Certificates & Qualifications 100
General installation instructions 102
Dimensioning of buffer storage tanks and domestic water storage tanks 104
Important notes regarding this catalogue / abbreviations 106
General terms and conditions 107
Contact persons 108
All prices are non-binding end customer prices and do not include value-added tax.
Table of Contents
4 I Product catalogue 2021
Solar storage tank Domestic water storage tank Buffer storage tank System Combined storage tank(Domestic water storage tank + Buffer storage tank) Stainless steel storage tank Other
ESS-PU SSH SSH-Plus EBS-PU BS HLS-Plus PSB HSO WWS-TS SPSX SPSX-G/SPSX-2G PSX-ECO PSX-G-ECO PS-BHKW GPS
(GroĂbuffer) PSFW /-G SKSW WKS-WP WKS HSS HBS HPS DWK DLB
Bare-tube heat exchanger Bare-tube heat exchanger Bare-tube heat exchanger GWTs Bare-tube heat exchanger Bare-tube heat exchanger
2 2 3 1 1 1 - 2 0 1 1 0 1 - 2 0 1 0 0 0 - 1 0 - 2 0 - 2 0 - 2 2 1 0 - -
Compressive strenght Compressive strenght Compressive strenght Com. st. Compressive strenght Compressive strenght
10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 3 bar 3 bar 3 bar 3 bar 6 bar 3 bar 3 bar 3 bar 3 bar 3 bar 10 bar 10 bar 10 bar 4/6/10 bar 11/16 bar
Insulation HS = PU rigid foam Insulation HS = PU rigid foam Insulation Insulation Insulation InsulationHS Fleece Fleece HS Fleece Fleece Fleece HS HS Fleece Fleece Fleece Fleece Fleece Fleece Fleece Fleece Fleece Fleece Fleece Fleece Fleece - -
Contents Contents Contents Contents Contents Contents
200 lto
500 l
300 lto
2.000 l
350 lto
800 l
120 lto
500 l
120 lto
2.000 l
150 lto
800 l
200 lto
2.000 l
120 lto
150 l
120 lto
200 l
200 l to
3.000 l
500 lto
2.000 l
200 l to
3.000 l
500 lto
2.000 l
500 lto
2.000 l
2.000 lto
10.000 l
500 lto
1.000 l
600 lto
1.500 l
600 lto
1.500 l
600 lto
1.500 l
200 lto
2.000 l
150 lto
2.000 l
150 lto
2.000 l
60 l to
3.000 l
40 lto
1.000 l
Standard energy efficiency class Standard energy efficiency class Standard energy efficiency class Class Standard energy efficiency class Standard energy efficiency class
- -
Detailed product information and technical data are provided on the following pages:
p. 10 p. 12 p. 14 p. 18 p. 20 p. 22 p. 24 p. 26 p. 28 p. 32 p. 34 p. 36 p. 38 p. 40 p. 42 p. 46 p. 54 p. 56 p. 58 p. 62 p. 64 p. 66 p. 72 p. 74
The suitable storage tank for your complete system Note: Special solutions such as the combination of various heat sources also allow for other applications.
â â â â â â â â â â â â Biogas plant plant / Biomass plant
â â â â â â â â â â â â Combined heat and power plant
â â â â â â â â â â â â Wood chip- / Wood burning plant
â â â â â â â â â â â Condensing power plant
â â â â â â â â â â â â Gas plant plant
â â â â â â â â â â â â Oil heating plant
â â â â â â â â â â â â â â â â Pellet heating heating
â â â â â â â â â â â â Solar heating plant
â â â â â Heating pump system
â â â â â â â â â â â Direct heating system
Overview of our storage tanks - the right solution for every heating system
Stratified guide channels
Stratified guide channels
www.huch.com I 5
Solar storage tank Domestic water storage tank Buffer storage tank System Combined storage tank(Domestic water storage tank + Buffer storage tank) Stainless steel storage tank Other
ESS-PU SSH SSH-Plus EBS-PU BS HLS-Plus PSB HSO WWS-TS SPSX SPSX-G/SPSX-2G PSX-ECO PSX-G-ECO PS-BHKW GPS
(GroĂbuffer) PSFW /-G SKSW WKS-WP WKS HSS HBS HPS DWK DLB
Bare-tube heat exchanger Bare-tube heat exchanger Bare-tube heat exchanger GWTs Bare-tube heat exchanger Bare-tube heat exchanger
2 2 3 1 1 1 - 2 0 1 1 0 1 - 2 0 1 0 0 0 - 1 0 - 2 0 - 2 0 - 2 2 1 0 - -
Compressive strenght Compressive strenght Compressive strenght Com. st. Compressive strenght Compressive strenght
10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar 3 bar 3 bar 3 bar 3 bar 6 bar 3 bar 3 bar 3 bar 3 bar 3 bar 10 bar 10 bar 10 bar 4/6/10 bar 11/16 bar
Insulation HS = PU rigid foam Insulation HS = PU rigid foam Insulation Insulation Insulation InsulationHS Fleece Fleece HS Fleece Fleece Fleece HS HS Fleece Fleece Fleece Fleece Fleece Fleece Fleece Fleece Fleece Fleece Fleece Fleece Fleece - -
Contents Contents Contents Contents Contents Contents
200 lto
500 l
300 lto
2.000 l
350 lto
800 l
120 lto
500 l
120 lto
2.000 l
150 lto
800 l
200 lto
2.000 l
120 lto
150 l
120 lto
200 l
200 l to
3.000 l
500 lto
2.000 l
200 l to
3.000 l
500 lto
2.000 l
500 lto
2.000 l
2.000 lto
10.000 l
500 lto
1.000 l
600 lto
1.500 l
600 lto
1.500 l
600 lto
1.500 l
200 lto
2.000 l
150 lto
2.000 l
150 lto
2.000 l
60 l to
3.000 l
40 lto
1.000 l
Standard energy efficiency class Standard energy efficiency class Standard energy efficiency class Class Standard energy efficiency class Standard energy efficiency class
- -
Detailed product information and technical data are provided on the following pages:
p. 10 p. 12 p. 14 p. 18 p. 20 p. 22 p. 24 p. 26 p. 28 p. 32 p. 34 p. 36 p. 38 p. 40 p. 42 p. 46 p. 54 p. 56 p. 58 p. 62 p. 64 p. 66 p. 72 p. 74
The suitable storage tank for your complete system Note: Special solutions such as the combination of various heat sources also allow for other applications.
â â â â â â â â â â â â Biogas plant plant / Biomass plant
â â â â â â â â â â â â Combined heat and power plant
â â â â â â â â â â â â Wood chip- / Wood burning plant
â â â â â â â â â â â Condensing power plant
â â â â â â â â â â â â Gas plant plant
â â â â â â â â â â â â Oil heating plant
â â â â â â â â â â â â â â â â Pellet heating heating
â â â â â â â â â â â â Solar heating plant
â â â â â Heating pump system
â â â â â â â â â â â Direct heating system
Overview of our storage tanks - the right solution for every heating system
HLV
nur bei 1000 L nur bei 1000 L
Lasche
Sensor sleeve
FRIWA
6 I Product catalogue 2021
NEW in the catalogue
www.huch.com I 7
New
in th
e ca
talo
gue
8 I Solar storage tanks · Product catalogue 2021
© iStock / Ilya Bushuev
Huch solar storage tankHot water convenience even when the sun doesn't shine.Our solar storage tanks are especially oriented to solar thermal installations. They have at least two large bare-tube heat exchangers and ensure that heat is rapidly transferred. The solar storage tanks can be easily combined with other heat generators, such as condenser boilers or a pellet heating system. Become part of the future and use regenerative energies. This goes easy on both the environment and your wallet/purse.
www.huch.com I 9
5
1
4
3
6
2
Quality features
High-grade bare-tube heat exchangersThanks to a special heat exchanger design and arrangement a high extraction grade of up to 96% is achieved.
Domestic water-suitedHygienically correct domestic water heating thanks to high-grade enamelling. An anode supplied as standard also provides protection from corrosion.
Connection stubsOur connection stubs are a standard 50 mm in length. The fleece insulation thus insulates any non-used connections. This cuts radiation losses and an improved energy efficiency is achieved by the storage tank.
Use of the entire storage tank capacityAn optimum hot water connection at the top of the storage tank means that the storage tank capacity is fully utilised.
Flexible positioning of the temperature sensorsSensor clamping strips allow the temperature sensor to be positioned at will. As a result, the Huch storage tanks are suitable for many application fields. (barring storage tanks with PU rigid foam; here firmly positioned sensor/controller connections).
Innovative highly efficient storage tank insulationThe high-grade Polyline© fleece insulation incl. a 100 mm lid and a 50 mm base insulation reduces heat loss by 10-15 % over soft foam.
PU rigid foam insulation - 50 mm high-grade polyurethane foam firmly wraps up the vessels in foam. No chimney effect develops and the insulation has excellent insulating properties.
1
2
3
4
5
6
The SSH solar storage tank is shown in the illustration.
Connection scheme
Schematic diagram â relevant standards and regulations must be observed!
Cold water
Wall-hung heater
hot water
Solar heating
Circulation
Sola
r sto
rage
tank
s
10 I Solar storage tanks · Product catalogue 2021
» Material: S235JR+N steel, internal enamelled, external primer coat » Compressive strenght: 10 bar» Technical features: two large bare-tube heat exchanger, Magnesium protection anode 1ÂŒâ, Sensor sleeve, Thermometer, Inspection flange 180 x 110 x LK 150» Connections: Standard 1Âœâ sleeve for retrofitting an electric heating, flat-sealing external threads» Insulation: 50 mm PU rigid foam insulation with Sky-coating» Levelling feet see list of accessories» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages from 84
Storage type ESS-PU 200 300 400 500
Price
ESS-PU with insulation [âŹ/item] 1129,- 1305,- 1595,- 1809,-
Order number
ESS-PU with insulation RAL 9006 16593 14598 13813 14971
In stock
Product description
Price / order number
Solar storage tank ESS-PU
Pellet heatingCondensing power plant
Oil heating plant Gas plantSolar heating
plantDirect heating system
Special solutions such as the combination of various heat sources also allow for other applications.
Circulation (Z)
Return flow (RL1)
Sensor/controller connections
Sensor/controller connections
Inlet flow (VL2)
Hot water (WW)
Inlet flow (VL1)
Return flow (RL2)
Cold water (KW)
Inspection flange with optional connection for additional heat sources (RFL)
Levelling feet (optional)
M8 thermometer option
Electric heating
www.huch.com I 11
Technical data
Storage type ESS-PU 200 300 400 500
Content [Litres] 200 300 400 500
Energy efficiency class C C C C
Heat retaining loss (with insulation) [Watt] 84 90 95 99
Diameter without insulation [mm] 500* 500* 600* 650*
Diameter with insulation [mm] 600 600 700 750
Insulation [mm] 50* 50* 50* 50*
Height with insulation [mm] 1232 1697 1660 1783
Tilted height [mm] 1370 1800 1800 1970
Heating surface top/bottom [m2] 0,6 / 0,8 0,8 / 1,2 1,0 / 1,5 1,2 / 1,8
Water content WT top/bottom [Litres] 3,8 / 5,0 5,0 / 7,5 6,3 / 9,4 7,5 / 11,3
Flow rate WT top/bottom [m3/h] 0,7 / 1,2 1,0 / 1,6 1,2 / 2,0 1,4 / 2,4
Pressure loss WT top/bottom [mbar] 30 / 70 35 / 90 45 / 120 55 / 250
NL number** top/bottom according to DIN 4708
1,23 / 3,6 1,8 / 8 2,1 / 11 2,5 / 14
Continuous output top/bottom according to DIN 4708 (10°/80°/45°)
[l/h] (kW) 410 (16,7) / 710 (28,9)
605 (24,6) / 970 (39,5)
720 (29,3) / 1180 (48,0)
830 (33,8) / 1400 (57,0)
max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10
max. T/ max. P - GWT-HZG*** [°C/bar] 160 / 25 160 / 25 160 / 25 160 / 25
Cold water / hot water AG (KW/WW) [Inch] G 1 G 1 G 1 G 1
Circulation AG (Z) [Inch] G Ÿ G Ÿ G Ÿ G Ÿ
Heat exchanger all AG (VL/RL) [Inch] G Ÿ G Ÿ G Ÿ G Ÿ
Electric heating IG (E-HZG) [Inch] G 1 œ G 1 œ G 1 œ G 1 œ
Nominal width of inspection flange (RFL) DN 110 DN 110 DN 110 DN 110
Sensor/controller connections (F1, F2) Sensor sleeve, internal diameter = 9 mm
Thermometer connections M8 thermometer option
Dimensions ESS-PU 200 300 400 500
KW [mm] 110 110 127 128
RL 1 [mm] 180 180 205 205
VL 1 [mm] 630 580 635 685
RL 2 [mm] 780 945 965 1020
Z [mm] 880 1045 1065 1125
VL 2 [mm] 990 1215 1261 1325
WW [mm] top top top top
E-HZG [mm] 705 770 770 920
Weight [kg] 85 114 166 215
* Insulation not removable. ** In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output. *** Operating media for heat exchanger: water in liquid state only. Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water.
Maintenance accessories ESS-PU 200 300 400 500
Anode [âŹ/item]Order number
35,- 05714
37,- 03679
42,-04041
62,-04042
Blind flange [âŹ/item]Order number
21,-03683
21,-03683
21,-03683
21,-03683
Flange seal [âŹ/item]Order number
13,-03684
13,-03684
13,-03684
13,-03684
Sola
r sto
rage
tank
s
12 I Solar storage tanks · Product catalogue 2021
Solar storage tank SSH
Product description
Price / Order number
Storage type SSH 301 301 401 501 751 1001 1500 2000
Price Ă=600 Ă=550
SSH without insulation [âŹ/item] - - - - 3217,- 3723,- 5460,- 6408,-
SSH with fleece insulation [âŹ/item] 1757,- 1747,- 2034,- 2276,- - - - -
Fleece insulation [âŹ/item] - - - - 695,- 901,- 1196,- 1339,-
Order number
SSH without insulation - - - - 17230 17236 23756 23553
SSH with fleece insulation RAL 9006
36641 36642 36643 36644 - - - -
Fleece insulation RAL 9006 - - - - 44928 44929 44930 44931
In stock
» Material: S235JR+N steel, internal enamelled, external primer coat» Compressive strenght: 10 bar» Technical features: two large bare-tube heat exchanger, Magnesium protection anode 1ÂŒâ (from 750 Litres is a impressed current anode a standard), Sensor clamping strip, Inspection flange 180 x 110 x LK 150 (over 750 Litres 280 x 200 x LK245), up to 1001 Litres is the thermometer enclosed in the scope of delivery» Connections: Standard 1Âœâ sleeve for retrofitting an electric heating, flat-sealing external threads» Insulation: removable 100 mm polyline fleece insulation including base and lid insulation» on request up to 5.000 liters possible (8 bar)» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages from 84.
Special solutions such as the combination of various heat sources also allow for other applications.
Pellet heatingCondensing power plant
Oil heating plant Gas plantSolar heating
plantDirect heating system
Hot water (WW)
Return flow (RL1)
Inlet flow(VL2)
Magnesium anode
Inlet flow (VL1)
Return flow (RL2)
Circulation (Z)
Cold water (KW)
Inspection flange with optional connection for additional heat sources (RFL)
Foot ring
Electric heating
M8 thermometer option
www.huch.com I 13
Technical data
Storage type SSH Ă=600 301 Ă=550 301 401 501 751 1001 1500 2000
Content [Litres] 300 325 400 500 750 1000 1500 2000
Energy efficiency class C C C C C C C C
Heat retaining loss [Watt] 92 100 102 112 131 146 168 186
Diameter without insulation [mm] 600 550 600 650 750 850 1000 1100
Diameter with insulation [mm] 800 750 800 850 950 1050 1200 1300
Insulation [mm] 100 100 100 100 100 100 100 100
Height with insulation [mm] 1353 1645 1725 1835 2082 2015 2250 2410
Tilted height [mm] 1320 1620 1690 1800 2050 2030 2260 2440
Heating surface top/bottom [m2] 1,0 / 1,3 1,0 / 1,4 1,2 / 1,7 1,5 / 2,1 1,9 / 2,7 1,9 / 2,9 2,0 / 4,0 2,0 / 4,0
Water content WT top/bottom [Litres] 6,3 / 8,2 6,3 / 8,8 7,6 / 10,7 9,4 / 13,2 16,0 / 22,8 16,0 / 24,5 17,0 /34,0 17,0 /34,0
Flow rate WT top/bottom [mÂł/h] 1,1 / 1,7 1,1 / 1,9 1,4 / 2,1 1,5 / 2,8 2,1 / 4,2 2,1 / 4,6 2,2 / 5,1 2,2 / 5,1
Pressure loss WT top/bottom [mbar] 40 / 60 40 / 80 50 / 130 60 / 280 40 / 180 40 / 200 42 / 265 42 / 265
NL number top/bottom ** according to DIN 4708
2 / 9 2 / 11 2,2 / 13 2,8 / 18 13 / 35 13 / 41 17 / 46 21 / 55
Continuous output top/bot-tom according to DIN 4708 (10°/80°/45°)
[l/h](kW)
660 (26,9) / 1005 (41,0)
660 (26,9) / 1130 (46,0)
790 (32,2) / 1270 (51,7)
905 (36,8) / 1620 (65,9)
1220 (49,7) / 2470 (100,5)
1220 (49,7) / 2690 (109,5)
1280 (52,1) /2990 (121,7)
1280 (52,1) /2990 (121,7)
max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10
max. T/ max. P - GWT-HZG*** [°C/bar] 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25
Cold water / hot water AG (KW/WW)
[Inch] G 1 G 1 G 1 G 1 G 1œ G 1œ G 2 G 2
Circulation AG (Z) [Inch] GŸ GŸ GŸ GŸ GŸ GŸ G 1 G 1
Heat exchanger all AG (VL/RL) [Inch] G 1 G 1 G 1 G 1 G 1Œ G 1Œ G 1œ G 1œ
Electric heating IG (E-HZG) [Inch] G 1 œ G 1 œ G 1 œ G 1 œ G 1 œ G 1 œ G 1œ G 1œ
Nominal width of inspection flange (RFL) DN 110 DN 110 DN 110 DN 110 DN 200 DN 200 DN 200 DN 200
Sensor/controller connections Sensor clamping strip
Thermometer connections M8 thermometer option No No
Dimensions
KW [mm] 120 110 120 130 157 190 230 255
RL 1 [mm] 220 205 220 225 280 350 375 400
VL 1 [mm] 570 675 690 875 967 920 1125 1150
RL 2 [mm] 773 950 1015 1020 1127 1140 1275 1300
Z [mm] 873 1050 1115 1120 1227 1240 1425 1450
VL 2 [mm] 1033 1290 1355 1490 1567 1525 1650 1675
WW [mm] 1156 1460 1528 1630 1855 1800 1860 2005
E-HZG [mm] 673 850 915 920 1032 1016 1200 1225
Weight [kg] 164 156 178 234 344* 400* 495* 590*
* Weight without Insulation. ** In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output. *** Operating media for heat exchanger: water in liquid state only. Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water.
Maintenance accessories SSH Ă=600 301 Ă=550 301 401 501 751 1001 1500 2000
Anode [âŹ/item]Order number
37,-03679
37,-03679
42,-04041
62,-04042
293,-04509
293,-04509
468,-24463
468,-24463
Blind flange [âŹ/item]Order number
21,-03683
21,-03683
21,-03683
21,-03683
88,-05148
88,-05148
88,-05148
88,-05148
Flange seal [âŹ/item]Order number
13,-03684
13,-03684
13,-03684
13,-03684
15,-01429
15,-01429
15,-01429
15,-01429
Sola
r sto
rage
tank
s
14 I Solar storage tanks · Product catalogue 2021
Solar storage tank SSH-Plus
Product description
Price / Order number
Storage type SSH-Plus 351 501 801
Price
SSH-Plus without insulation [âŹ/item] - - 3815,-
SSH-Plus mit FleeceInsulation [âŹ/item] 2246,- 2774,- -
FleeceInsulation [âŹ/item] - - 673,-
Order number
SSH-Plus without insulation - - 25310
SSH-Plus mit FleeceInsulation RAL 9006 50515 50516 -
FleeceInsulation RAL 9006 - - 44998
In stock
» Material: S235JR+N steel, internal enamelled, external primer coat» Compressive strenght: 10 bar» Technical features: overhead double bare-tube heat exchanger (equal tube length inside / outside, operating modes of heat exchanger pair: parallel mode / single mode / series mode), solar heat exchanger positioned at the bottom, Magnesium protection anode 1ÂŒâ (from 800 Litres impressed current anode), Sensor clamping strip, Inspection flange 180 x 110 x LK 150» Connections: Standard 1Âœâ sleeve for retrofitting an electric heating, flat-sealing external threads» Insulation: removable 100 mm polyline fleece insulation including base and lid insulation» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages from 84.
Special solutions such as the combination of various heat sources also allow for other applications.
Heatingpump
Pellet heating
Condensing power plant
Oil heating plant
Gas plant
Solar heating plant
Direct heating system
Hot water (WW)
Return flow (RL1)
Internal Inlet flow (VL i)
External Inlet flow (VL a)
Magnesium anode
Internal Return flow (RL i)
Inlet flow (VL1)
External Return flow (RL a)
Circulation (Z)
Cold water (KW)
Inspection flange with optional connection for additional heat sources (RFL)
Foot ring
Electric heating
www.huch.com I 15
Technical data
Storage type SSH-Plus 351 501 801
Content [Litres] 350 500 800
Energy efficiency class C C C
Heat retaining loss (with insulation) [Watt] 98 112 135
Diameter without insulation [mm] 600 650 800
Diameter with insulation [mm] 800 850 1000
Insulation [mm] 100 100 100
Height with insulation [mm] 1678 1909 1970
Tilted height [mm] 1620 1860 1950
Heating surface top/bottom [mÂČ] 3,3(2x1,65) / 1,3 4,95(2x2,43) / 1,8 6,0(2x3,0) / 2,0
Water content WT top/bottom [Litres] 21 / 8,2 31 / 11 38 / 13
Flow rate WT top/bottom [mÂł/h] 3,6 / 1,7 4,0 / 2,1 4,0 / 2,7
Pressure loss WT top Series/Parallel/Single mode
[mbar] 410 / 60 / 200 750 / 110 / 350 830 / 120 / 420
Pressure loss WT bottom [mbar] 60 130 170
NL number* according to DIN 4708 top (parallel)/bottom 18 / 9 35 / 13 35 / 20
Continuous output top/bottom according to DIN 4708 (10°/80°/45°)
[l/h](kW)
2100 (85,5) / 1000 (40,7)
2500 (101,8) / 1270 (51,7)
2500 (101,8) / 1650 (67,2)
max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10
max. T/ max. P - GWT-HZG*** [°C/bar] 160 / 25 160 / 25 160 / 25
Cold water / hot water AG (KW/WW) [Inch] G 1 G 1 G 1 œ
Circulation AG (Z) [Inch] GŸ GŸ GŸ
Heat exchanger all AG (VL/RL) [Inch] G 1 G 1 G 1
Electric heating IG (E-HZG) [Inch] G 1 œ G 1 œ RFL
Nominal width of inspection flange (RFL) DN 110 DN 110 DN 110
Sensor/controller connections Sensor clamping strip
Thermometer connections for all storage tanks: no
Dimensions
KW [mm] 120 130 160
RL1 [mm] 218 217 245
VL1 [mm] 568 637 645
RL (i) [mm] 668 737 745
RL (a) [mm] 751 820 845
Z [mm] 1063 1218 1045
VL (a) [mm] 1123 1430 1415
VL (i) [mm] 1323 1567 1535
WW [mm] 1461 1704 1740
E-HZG [mm] 618 687 -
Weight [kg] 172 255 400
Maintenance accessories SSH-Plus 351 501 801
Anode [âŹ/item]Order number
62,-04042
70,-04390
468,-26054
Blind flange [âŹ/item]Order number
21,-03683
21,-03683
21,-03683
Flange seal [âŹ/item]Order number
13,-03684
13,-03684
13,-03684
* In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output. ** Operating media for heat exchanger: water in liquid state only. Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water.
Direct heating system
Sola
r sto
rage
tank
s
16 I Domestic water storage tanks · Product catalogue 2021
© panthermedia.net /kurhan
Huch domestic water storage tankWater - the elixir of lifeOur domestic water storage tanks find their place in a hygienically trouble-free preparation of domestic water owing to quality-tested enamelling. We guarantee maximum quality on the basis of German standards and technical norms. The domestic water storage tanks can be combined with various heat generators.
www.huch.com I 17
1
2
3
4
5
The HLS-Plus domestic water storage tank is shown in the illustration.
1
4
3
6
2
Quality features
Connection scheme
Schematic diagram â relevant standards and regulations must be observed!
Cold water
Heat pump
High-grade bare-tube heat exchangersThanks to a special heat exchanger design and arrangement a high extraction grade of up to 96% is achieved.
Domestic water-suitedHygienically correct domestic water heating thanks to high-grade enamelling. An anode supplied as standard also provides protection from corrosion.
Connection stubsOur connection stubs are a standard 50 mm in length. The fleece insulation thus insulates any non-used connections. This cuts radiation losses and an improved energy efficiency is achieved by the storage tank.
Use of the entire storage tank capacityAn optimum hot water connection at the top of the storage tank means that the storage tank capacity is fully utilised.
Flexible positioning of the temperature sensorsSensor clamping strips allow the temperature sensor to be positioned at will. As a result, the Huch storage tanks are suitable for many application fields. (barring storage tanks with PU rigid foam; here firmly positioned sensor/controller connections).
Innovative highly efficient storage tank insulationThe high-grade Polyline© fleece insulation incl. a 100 mm lid and a 50 mm base insulation reduces heat loss by 10-15 % over soft foam.
PU rigid foam insulation - 50 mm high-grade polyurethane foam firmly wraps up the vessels in foam. No chimney effect develops and the insulation has excellent insulating properties.
5
6
Dom
estic
wat
er s
tora
ge ta
nks
18 I Domestic water storage tanks · Product catalogue 2021
Domestic water storage tank EBS-PU
Price / Order number
Storage type EBS-PU 120 150 200 300 400 500
Price
EBS-PU with insulation [âŹ/item] 851,- 913,- 994,- 1206,- 1456,- 1694,-
Order number
EBS-PU with insulation RAL 9006 14300 15280 14597 14596 15186 14599
In stock
Product description» Material: S235JR+N steel, internal enamelled, external primer coat » Compressive strenght: 10 bar» Technical features: large bare-tube heat exchanger, Magnesium protection anode 1ÂŒâ, Sensor sleeve, Thermometer, Inspection flange 180 x 110 x LK 150» Connections: Standard 1Âœâ sleeve for retrofitting an electric heating, flat-sealing external threads» Insulation: 50 mm PU rigid foam insulation with Sky-coating» Levelling feet see list of accessories» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages from 84.
Special solutions such as the combination of various heat sources also allow for other applications.
Pellet heatingCondensing power plant
Oil heating plant Gas plant Direct heating
system
Hot water (WW)
Sensor/controller connections (F1)
Inlet flow (VL)
Return flow (RL)
Circulation (Z)
Cold water (KW)
Inspection flange with optional connection for additional heat sources (RFL)
Levelling feet (optional)
Electric heating
M8 thermometer option
www.huch.com I 19
Storage type EBS-PU 120 150 200 300 400 500
Content [Litres] 120 150 200 300 400 500
Energy efficiency class C C C C C C
Heat retaining loss (with insulation) [Watt] 69 73 84 90 95 99
Diameter without insulation [mm] 500* 500* 500* 500* 600* 650*
Diameter with insulation [mm] 600 600 600 600 700 750
Insulation [mm] 50* 50* 50* 50* 50* 50*
Height with insulation [mm] 814 969 1232 1697 1660 1783
Tilted height [mm] 1011 1140 1370 1800 1750 1970
Heating surface [mÂČ] 0,6 0,7 0,9 1,2 1,5 1,8
Water content WT [Litres] 3,8 4,4 5,7 7,5 9,4 11,3
Flow rate WT [mÂł/h] 0,8 1,0 1,2 1,6 2,0 2,4
Pressure loss WT [mbar] 30 50 70 60 120 250
NL number** according to DIN 4708 1,7 2,1 3,6 8 11 14
Continuous output according to DIN 4708 (10°/80°/45°)
[l/h](kW)
460 (18,7) 580 (23,6) 710 (28,9) 970 (39,5) 1180 (48,0) 1400 (57,0)
max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10
max. T/ max. P - GWT-HZG*** [°C/bar] 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25
Cold water / hot water AG (KW/WW) [Inch] G 1 G 1 G 1 G 1 G 1 G 1
Circulation AG (Z) [Inch] G Ÿ G Ÿ G Ÿ G Ÿ G Ÿ G Ÿ
Heat exchanger AG (VL/RL) [Inch] G Ÿ G Ÿ G Ÿ G Ÿ G Ÿ G Ÿ
Electric heating IG (E-HZG) [Inch] G 1 œ G 1 œ G 1 œ G 1 œ G 1 œ G 1 œ
Nominal width of inspection flange (RFL) DN 110 DN 110 DN 110 DN 110 DN 110 DN 110
Sensor/controller connections (F1) for all storage tanks: Sensor sleeve, internal diameter = 9 mm
Thermometer connections for all storage tanks: M8 thermometer option
Dimensions
KW [mm] 110 110 110 110 127 128
RL [mm] 180 180 180 180 205 205
VL [mm] 450 520 630 580 635 685
Z [mm] 520 660 780 1045 1065 1125
WW [mm] for all storage tanks: top
E-HZG [mm] 520 600 800 770 770 920
Weight [kg] 59 66 73 94 151 195
Maintenance accessories EBS-PU 120 150 200 300 400 500
Anode [âŹ/item]Order number
29,-05712
34,-05713
35,-05714
37,-03679
42,-04041
62,-04042
Blind flange [âŹ/item]Order number
21,-03683
21,-03683
21,-03683
21,-03683
21,-03683
21,-03683
Flange seal [âŹ/item]Order number
13,-03684
13,-03684
13,-03684
13,-03684
13,-03684
13,-03684
* Insulation not removable ** In order to achieve the specified NL number, the boiler out *** Operating media for heat exchanger: water in liquid state only. Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water.
Technical data
Dom
estic
wat
er s
tora
ge ta
nks
20 I Domestic water storage tanks · Product catalogue 2021
Domestic water storage tank BS
Price / Order number
Storage type BS 122 152 202 301 401 501 751 1001 1500 2000
Price
BS without insulation [âŹ/item] - - - - - - 2896,- 3394,- 5130,- 6006,-
BS with fleece insulation [âŹ/item] 1148,- 1205,- 1336,- 1584,- 1856,- 2072,- - - - -
Fleece insulation [âŹ/item] - - - - - - 695,- 901,- 1196,- 1339,-
Order number
BS without insulation - - - - - - 17227 17233 24464 24471
BS with fleece insulation RAL 9006
36659 36634 36635 36637 36638 36639 - - - -
Fleece insulation RAL 9006 - - - - - - 44928 44929 44930 44931
In stock
Product description» Material: S235JR+N steel, internal enamelled, external primer coat » Compressive strenght: 10 bar» Technical features: large bare-tube heat exchanger, Magnesium protection anode 1ÂŒâ (from 750 Litres impressed current anode), Sensor clamping strips, Inspection flange 180 x 110 x LK 150 (ab 750 Litres 280 x 200 x LK245), up to 1001 Litres is the thermometer enclosed in the scope of delivery Note: for BS 1500 & 2000 Litres the insertion of an electric heating only possible via the E-HZG sleeve, do not overlie the flange!» Connections: Standard 1Âœâ sleeve for retrofitting an electric heating, flat-sealing external threads» Insulation: removable 100 mm polyline fleece insulation including base and lid insulation» on request up to 5.000 liters possible» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages from 84
Special solutions such as the combination of various heat sources also allow for other applications.
Pellet heatingCondensing power plant
Oil heating plant Gas plant Direct heating
system
Hot water (WW)
Return flow (RL)
Magnesium anode
Inlet flow (VL)
Circulation (Z)
Cold water (KW)
Inspection flange with optional connection for additional heat sources (RFL)
Foot ring
Electric heating
M8 thermometer option
www.huch.com I 21
Technical data
Storage type BS 122 152 202 301 401 501 751 1001 1500 2000
Content [Litres] 120 150 200 325 400 500 750 1000 1500 2000
Energy efficiency class C C C C C C C C C C
Heat retaining loss (with insulation)
[Watt] 65 74 83 100 102 112 131 145 168 186
Durchmesser without Insulation [mm] 500 500 500 550 600 650 750 850 1000 1100
Diameter with insulation [mm] 700 700 700 750 800 850 950 1050 1200 1300
Insulation [mm] 100 100 100 100 100 100 100 100 100 100
Height with insulation [mm] 864 1022 1282 1645 1725 1835 2082 2015 2250 2410
Tilted height [mm] 850 1000 1250 1620 1690 1800 2050 2030 2260 2440
Heating surface [mÂČ] 0,7 1,0 1,4 1,4 1,7 2,1 2,7 2,9 4,0 4,0
Water content WT [Litres] 4,5 6,3 8,8 8,8 10,7 13,2 22,8 24,5 34,0 34,0
Flow rate WT [mÂł/h] 1,0 1,3 1,6 1,9 2,1 2,7 4,2 4,6 5,1 5,1
Pressure loss WT [mbar] 30 50 70 80 130 280 180 200 265 265
NL number** according to DIN 4708 1,9 2,5 4,8 11 13 18 35 41 46 55
Continuous output nach DIN 4708 (10°/80°/45°)
[l/h](kW)
580 (23,6)
750 (30,5)
940 (38,3)
1130 (46,0)
1270 (51,7)
1620 (65,9)
2470(100,5)
2690 (109,5)
2990 (121,7)
2990 (121,7)
max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10
max. T/ max. P - GWT-HZG*** [°C/bar] 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25
Cold water / hot water AG (KW/WW)
[Inch] G 1 G 1 G 1 G 1 G 1 G 1 G 1œ G 1 œ G 2 G 2
Circulation AG (Z) [Inch] G Ÿ G Ÿ G Ÿ G Ÿ G Ÿ G Ÿ G Ÿ G Ÿ G 1 G 1
Heat exchanger AG (VL/RL) [Inch] G 1 G 1 G 1 G 1 G 1 G 1 G 1Œ G 1Œ G 1œ G 1œ
Electric heating IG (E-HZG) [Inch] G 1œ G 1œ G 1œ G 1œ G 1œ G 1œ G 1œ G 1œ G 1œ G 1œ
Nominal width of inspection flange (RFL) DN 110 DN 110 DN 110 DN 110 DN 110 DN 110 DN 200 DN 200 DN 200 DN 200
Sensor/controller connections Sensor clamping strip
Thermometer connections for all storage tanks 122 - 1001 Litres: M8 thermometer option No No
Dimensions
KW [mm] 110 110 110 110 120 130 157 190 230 255
RL [mm] 190 190 190 205 220 225 280 350 375 400
VL [mm] 460 550 725 675 690 875 967 920 1125 1150
Z [mm] 570 660 835 1050 1115 1120 1227 1240 1425 1450
WW [mm] 681 839 1099 1460 1528 1630 1855 1800 1860 2005
E-HZG [mm] 520 600 800 850 915 920 1032 1016 1200 1225
Weight [kg] 59 74 89 136 162 189 280* 373* 460* 560*
Maintenance accessories BS 122 152 202 301 401 501 751 1001 1500 2000
Anode [âŹ/item]Order number
29,-05712
34,-05713
35,-05714
37,-03679
42,-04041
62,-04042
293,-04509
293,-04509
468,-24463
468,-24463
Blind flange [âŹ/item]Order number
21,-03683
21,-03683
21,-03683
21,-03683
21,-03683
21,-03683
88,-05148
88,-05148
88,-05148
88,-05148
Flange seal [âŹ/item]Order number
13,-03684
13,-03684
13,-03684
13,-03684
13,-03684
13,-03684
15,-01429
15,-01429
15,-01429
15,-01429
* Weight without insulation. ** In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output. *** Operating media for heat exchanger: water in liquid state only. Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water.
Dom
estic
wat
er s
tora
ge ta
nks
22 I Domestic water storage tanks · Product catalogue 2021
Domestic water storage tank HLS-Plus
Price / Order number
Storage type HLS-Plus 150 200 301 401 501 801
Price
HLS-Plus without insulation [âŹ/item] - - - - - 3164,-
HLS-Plus with insulation [âŹ/item] 1090,- 1215,- 1710,- 2112,- 2243,- -
Fleece insulation [âŹ/item] - - - - - 716,-
Order number
HLS-Plus without insulation - - - - - 26549
HLS-Plus with fleece insulation RAL 9006
50524 50526 50527 50531 50533 -
Fleece insulation RAL 9006 - - - - - 45004
In stock
Product description» Material: S235JR+N steel, internal enamelled, external primer coat» Compressive strenght: 10 bar» Technical features: double bare-tube heat exchanger from 300 Litres (equal tube length inside / outside, operating modes of heat exchanger pair: parallel mode / single mode / series mode), Magnesium protection anode 1ÂŒâ (from 800 Litres impessed current anode), Sensor clamping strip, Inspection flange 180 x 110 x LK 150 » Connections: flat-sealing external threads» Insulation: removable 100 mm polyline fleece insulation including base and lid insulation» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages from 84.
Special solutions such as the combination of various heat sources also allow for other applications.
Heating pump
Note illustration.: Double bare-tube heat exchanger from 300 liters.
Pellet heatingCondensing power plant
Oil heating plant Gas plant Direct heating
system
Hot water (WW)
Internal Return flow (RL i)
External Return flow (RL a)
Internal Inlet flow (VL i)
Magnesium anode
Circulation (Z)
External Inlet flow (VL a)
Cold water (KW)
Inspection flange with optional connection for additional heat sources (RFL)
Foot ring
www.huch.com I 23
Technical data
* In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output. ** Operating media for heat exchanger: water in liquid state only. Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water.
Storage type HLS-Plus 150 200 301 401 501 801
Content [Litres] 150 200 300 400 500 800
Energy efficiency class C C C C C C
Heat retaining loss (with insulation)
[Watt] 74 83 92 102 112 135
Diameter without insulation [mm] 500 500 600 650 650 800
Diameter with insulation [mm] 700 700 800 850 850 1000
Insulation [mm] 100 100 100 100 100 100
Height with insulation [mm] 1022 1285 1340 1610 1835 1872
Tilted height [mm] 1000 1250 1380 1580 1800 1850
Heating surface [mÂČ] 1,5 2,0 3,8 (2 x 1,9) 5 (2 x 2,5) 5 (2 x 2,5) 6,0 (2 x 3,0)
Water content WT [Litres] 9,4 12,6 25 (2 x 12,5) 32 (2 x 16) 32 (2 x 16) 38 (2x19)
Flow rate WT [mÂł/h] 1,7 2,3 3,6 3,8 4,0 4,0
Pressure loss WT Series / Parallel / Single
[mbar] 60 130 680/85/200 720/100/320 750/110/350 830/120/420
NL number* according to DIN 4708 2,8 5,1 19,2 27,3 35 37
Continuous output according to DIN 4708 (10°/80°/45°)
[l/h](kW)
980 (39,9)
1350(55,0)
2200(89,6)
2500(101,8)
2500(101,8)
2500(101,8)
max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10
max. T/ max. P - GWT-HZG** [°C/bar] 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25 160 / 25
Cold water/hot water AG (KW/WW) [Inch] G 1 G 1 G 1 G 1 G 1 G 1
Circulation AG (Z) [Inch] GŸ GŸ GŸ GŸ GŸ GŸ
Heat exchanger AG (Vl i,a) [Inch] G 1 G 1 G 1 G 1 G 1 G 1
Heat exchanger AG (RL i,a) [Inch] G 1 G 1 G 1 G 1 G 1 G 1
Electric heating for all storage tanks: possible via inspection flange
Nominal width of inspection flange (RFL) DN 110 DN 110 DN 110 DN 110 DN 110 DN 110
Sensor/controller connections Sensor clamping strip
Thermometer connections for all storage tanks: no
Dimensions
KW [mm] 110 110 120 130 130 164
RL (i) [mm] 180 180 218 227 227 261
RL (a) [mm] - - 301 310 310 344
Z [mm] 522 522 706 802 802 776
VL (a) [mm] - - 829 940 940 914
VL (i) [mm] 700 875 966 1151 1151 1051
WW [mm] 836 1099 1196 1404 1630 1638
Weight [kg] 78 97 158 212 227 370
Maintenance accessories HLS-Plus 150 200 301 401 501 801
Anode [âŹ/item]Order number
34,-05713
35,-05714
42,-04041
62,-04042
70,-04390
468,-26054
Blind flange [âŹ/item]Order number
21,-03683
21,-03683
21,-03683
21,-03683
21,-03683
21,-03683
Flange seal [âŹ/item]Order number
13,-03684
13,-03684
13,-03684
13,-03684
13,-03684
13,-03684
Dom
estic
wat
er s
tora
ge ta
nks
24 I Domestic water storage tanks · Product catalogue 2021
Domestic water storage tank PSB
Price / Order number
Storage type PSB 200 300 400 500 500 750 1000 1500 2000
Price Ă=600 Ă=650
PSB without insulation [âŹ/item] - - - - - 1908,- 2381,- 3609,- 4420,-
PSB with fleece insulation [âŹ/item] 1228,- 1407,- 1630,- 1805,- 1872,- - - - -
Fleece insulation [âŹ/item] - - - - - 695,- 815,- 1032,- 1347,-
Order number
PSB without insulation - - - - - 17160 17161 21812 21823
PSB with fleece insulation RAL 9006
50535 50536 50544 50558 50559 - - - -
Fleece insulation RAL 9006 - - - - - 45010 45011 45012 45013
In stock
Product description» Material: S235JR+N steel, internal enamelled, external primer coat » Compressive strenght: 10 bar» Technical features: Magnesium protection anode 1ÂŒâ , inspection opening 280 x 200 x LK 245» Connections: flat-sealing external threads» Insulation: removable 100 mm polyline fleece insulation including base and lid insulation» on request up to 5.000 liters possible (8 bar)» Energy efficiency class "B" until 500 Litres on request» Accessories: are on the pages from 84.
Special solutions such as the combination of various heat sources also allow for other applications.
Pellet heatingCondensing power plant
Oil heating plant Gas plant Direct heating
system
Connection (A2)
Sensor/controller connections (F1)
Connection (A1)
Foot ring
Inspection flange with optional connection for additional heat sources (RFL)
www.huch.com I 25
Technical data
* Weight without Insulation. Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water.
Storage type PSB 200 300 400 500 500 750 1000 1500 2000Ă=600 Ă=650
Content [Litres] 200 300 400 500 500 750 1000 1500 2000
Energy efficiency class C C C C C C C C C
Heat retaining loss (with insulation)
[Watt] 83 92 102 112 112 131 145 168 186
Diameter without insulation [mm] 550 550 600 600 650 750 850 1000 1100
Diameter with insulation [mm] 750 750 800 800 850 950 1050 1200 1300
Insulation [mm] 100 100 100 100 100 100 100 100 100
Height with insulation [mm] 1070 1550 1630 1980 1790 1970 2010 2250 2410
Tilted height [mm] 1080 1550 1590 1920 1750 1945 2090 2260 2440
max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10
Loading/unloading connections AG (A1, A2)
[Inch] G1 G1 G1 G1 Œ G1 œ G1 Œ G1 Œ G2 G2
Electric heating for all storage tanks: possible via inspection flange
Nominal width of inspection flange (RFL) DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200 DN 200
Sensor/controller connections (F1-F3)
[Inch] Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ
Thermometer connections (F1-F3)
[Inch] Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ
Ventilation [Inch] Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ
Anode optional (ANO 1) [Inch] - 1 Œ 1 Œ 1 Œ 1 Œ 1 Œ 1 Œ 1 Œ 1 Œ
Anode optional (ANO 2) [Inch] 1 Œ 1 Œ 1 Œ 1 Œ 1 Œ 1 Œ 1 Œ 1 Œ 1 Œ
Dimensions
A1 [mm] 215 215 245 245 245 265 285 340 365
RFL, F1 [mm] 320 320 350 350 350 370 390 445 470
ANO 1 [mm] - 570 600 600 600 620 640 645 670
F 2 [mm] 550 820 850 980 850 950 920 1100 1185
ANO 2 [mm] 690 1170 1200 1530 1365 1500 1470 1760 1905
A2, F3 [mm] 790 1270 1300 1630 1465 1600 1570 1860 2005
Weight [kg] 90 118 129 160 160 225* 305* 390* 485*
Maintenance accessories PSB 200 300 400 500 500 750 1000 1500 2000
Anode [âŹ/item]Order number
35,-05714
37,-03679
42,-04041
62,-04042
62,-04042
70,-04390
70,-04390
70,-04390
70,-04390
Blind flange [âŹ/item]Order number
88,-05148
88,-05148
88,-05148
88,-05148
88,-05148
88,-05148
88,-05148
88,-05148
88,-05148
Flange seal [âŹ/item]Order number
15,-01429
15,-01429
15,-01429
15,-01429
15,-01429
15,-01429
15,-01429
15,-01429
15,-01429
Additionally integrated flange
» specified standard position, see pages with details on storage types» closed with seal and blind flange» flange enamelled» for the installation of a finned tube heat exchangers or an electric heating
Price [âŹ/item]: 270,-
Dom
estic
wat
er s
tora
ge ta
nks
26 I Domestic water storage tanks · Product catalogue 2021
Domestic water storage tank HSO
Price / Order number
Storage type HSO 120 150
Price
HSO with insulation [âŹ/item] 1044,- 1132,-
Order number
HSO with insulation RAL 9006 37387 38328
In stock
Product description» Material: S235JR+N steel, internal enamelled, external primer coat » Compressive strenght: 10 bar» Technical features: Bar-tube heat exchanger, Magnesium protection anode 1 Œ", Sensor sleeve, Levelling feets, Inspection flange 210 x 150 x LK 180 (top)» Connections: at the top of the storage tank, flat-sealing external threads» Insulation: 50 mm PU rigid foam insulation with Sky-coating» HSO 120 Litres in Energy efficiency class "B" on request» Accessories: are on the pages from 84.
Special solutions such as the combination of various heat sources also allow for other applications.
Pellet heatingCondensing power plant
Oil heating plant Gas plant Direct heating
system
Cold water (KW)
Return flow (RL)
Inlet flow (VL)
Circulation (Z)Hot water (WW)
Draining
www.huch.com I 27
Technical data
* Insulation not removable. ** In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output. *** Operating media for heat exchanger: water in liquid state only. Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water.
Storage type HSO 120 150
Content [Litres] 120 150
Energy efficiency class C C
Heat retaining loss (with insulation) [Watt] 69 73
Diameter without insulation [mm] 500* 500*
Diameter with insulation [mm] 600 600
Insulation [mm] 50* 50*
Height with insulation [mm] 835 1010
Tilted height [mm] 1045 1160
Heating surface [mÂČ] 1,0 1,3
Water content WT [Litres] 7,5 8,2
Flow rate WT [mÂł/h] 1,7 1,9
Pressure loss WT [mbar] 100 120
NL number** according to DIN 4708 1,8 2,1
Continuous output according to DIN 4708(10°/80°/45°)
[l/h](kW)
800 (33) 920 (38)
max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10
max. T/ max. P - GWT-HZG*** [°C/bar] 160 / 25 160 / 25
Cold water / hot water AG (KW/WW) [Inch] G Ÿ G Ÿ
Circulation AG (Z) [Inch] G Ÿ G Ÿ
Heat exchanger AG (VL/RL) [Inch] G Ÿ G Ÿ
Electric heating for all storage tanks: no
Nominal width of inspection flange (RFL) DN 110 DN 110
Sensor/controller connections (F) for all storage tanks: immersion sleeve, Di = 9 mm
Thermometer connections for all storage tanks: no
Draining (EL) Rp œ Rp œ
Weight [kg] 88 93
Maintenance accessories HSO 120 150
Anode [âŹ/item]Order number
25,-05712
25,-05712
Blind flange with connection sleeve G 1 œ"
[âŹ/item]Order number
45,-46213
45,-46213
Flange seal [âŹ/item]Order number
32,-38777
32,-38777
Did you know that...... The compact design of low-height storage tanks is often a reason for them being installed when flats are modernized. The floor-standing system storage tank is eminently suited for com-bination with all wall-suspended gas condensing devices.
The improved lid construction makes anode replacement easier as part of the recommended annual maintenance.
Dom
estic
wat
er s
tora
ge ta
nks
28 I Domestic water storage tanks · Product catalogue 2021
Domestic water storage tank WWS-TS
Price / Order number
Storage type WWS-TS 120 150 200
Price
WWS-TS with insulation [âŹ/item] 1399,- 1455,- 1791,-
Order number
WWS-TS with insulation RAL 9006 16818 16822 16826
In stock
Product description» Material: S235JR+N steel, internal enamelled, external primer coat » Compressive strenght: 10 bar» Technical features: large bare-tube heat exchanger, Magnesium protection anode M8, Immersion sleeve, Levelling feet, Inspection flange 180 x 110 x LK 150, Capillary remote-reading thermometer» Connections: flat-sealing external threads» Insulation: PU rigid foam insulation with coating made of paint- coated steel plate» loadable with 280 kg within the load area***» WWS-TS 120 Litres in Energy efficiency class "B" on request» Accessories: are on the pages from 84.
Special solutions such as the combination of various heat sources also allow for other applications.
Pellet heatingCondensing power plant
Oil heating plant Gas plant Direct heating
system
Hot water (WW) Thermometer
Anode (M8)
Sensor/controller connections
Inlet flow (VL) / Return flow (RL)
Circulation (Z)
Cold water (KW)
Levelling feet
www.huch.com I 29
Technical data
Storage type WWS-TS 120 150 200
Content [Litres] 120 150 200
Energy efficiency class C C C
Heat retaining loss (with insulation) [Watt] 69 73 84
Height x width x length with insulation [mm] 570 x 610 x 820* 570 x 610 x 965* 660 x 700 x 990*
Insulation [mm] - - -
Heating surface [mÂČ] 0,76 0,76 0,9
Water content WT [Litres] 5,0 5,0 5,7
Flow rate WT [mÂł/h] 1,0 1,0 1,1
Pressure loss WT [mbar] 80 80 90
NL number** according to DIN 4708 1,5 2 2,3
Continuous output according to DIN 4708 (10°/80°/45°)
[l/h](kW)
610 (24,8) 610 (24,8) 640 (26,0)
max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10
max. T/ max. P - GWT-HZG [°C/bar] 110 / 16 110 / 16 110 / 16
Cold water / hot water (KW/WW) [Inch] R Ÿ R Ÿ R Ÿ
Circulation (Z) [Inch] R Ÿ R Ÿ R Ÿ
Heat exchanger (VL/RL) [Inch] R Ÿ R Ÿ R Ÿ
Electric heating for all storage tanks: no
Nominal width of inspection flange (RFL) for all storage tanks: DN 110
Sensor/controller connections (F) for all storage tanks: immersion sleeve, Di = 9 mm
Thermometer connections for all storage tanks: Capillary remote-read thermometer
Weight [kg] 84 96 113
Maintenance accessories WWS-TS 120 150 200
Anode [âŹ/item]Order number
25,-05328
25,-05328
29,-10892
Flange seal [âŹ/item]Order number
26,-38777
26,-38777
26,-38777
* Insulation not removable. ** In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output. *** min. 4 supporting points within the load area: longitudinal on a 150-200 mm strip from the centre axis, transverse 100 mm from the outer edge. Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water.
Dom
estic
wat
er s
tora
ge ta
nks
30 I Buffer storage tanks · Product catalogue 2021
© panthermedia.net / Igor Yaruta
Huch buffer storage tankThe all-rounder among the storage tanksOur buffer storage tanks are used as the central unit in modern heating systems. It stores excess heat and offsets any temperature variations. It makes older retrofitted heating systems efficient again and saves you money. It can be used for domestic water preparation in combination with a fresh water station.
www.huch.com I 31
High-grade bare-tube heat exchangersThanks to a special heat exchanger design and arrange-ment a high extraction grade of up to 96% is achieved.
Optimum temperature stratificationStratification guiding channels and baffle plates ensure that temperature swirls in the storage tank are reduced.
Connection stubsOur connection stubs are a standard 50 mm in length. The fleece insulation thus insulates any non-used connections. This cuts radiation losses and an improved energy efficiency is achieved by the storage tank.
Manifold connection scopeOur buffer storage tanks have a host of connections. This makes possible an optimum system attachment for the most varied of applications.
Use of the entire storage tank capacityAn optimum hot water connection at the top of the sto-rage tank means that the storage tank capacity is fully utilised.
Flexible positioning of the temperature sensorsSensor clamping strips allow the temperature sensor to be positioned at will. As a result, the Huch storage tanks are suitable for many application fields.
Innovative highly efficient storage tank insulationThe high-grade Polyline© fleece insulation incl. a 100 mm lid and a 50 mm base insulation reduces heat loss by 10-15 % over soft foam.
Universally deployableFor system applications in association with regenerative heat generators and fresh water stations.
1
2
3
4
5
6
The SPSX-2G buffer storage tank is shown in the illustration.
1
4
3
2
7
8
7
5
Quality features
Connection scheme
Schematic diagram â relevant standards and regulations must be observed!
Cold water
FRIWA
Wood heating
Buff
er s
tora
ge ta
nks
32 I Buffer storage tanks · Product catalogue 2021
Buffer storage tank SPSX
Price / Order number
Storage type SPSX 200 300 400 500 600 800 850 1000 1000 1100 1500 2000 3000
Price Ă=790 Ă=850
SPSX without insulation [âŹ/item] - - - - 765,- 794,- 811,- 867,- 880,- 941,- 1209,- 1618,- 4377,-
SPSX with fleece insulation [âŹ/item] 891,- 1022,- 1135,- 1156,- - - - - - - - - -
Fleece insulation RAL 9006 [âŹ/item] - - - - 606,- 621,- 664,- 678,- 780,- 797,- 1088,- 1215,- 1340,-
Order number
SPSX without insulation - - - - 22455 22473 22486 22501 23886 22512 22522 22541 22559
SPSX with fleece insulation 48664 48719 48725 48731 - - - - - - - - -
Fleece insulation RAL 9006 - - - - 44954 44955 44956 44957 44958 44959 44960 44966 44973
In stock
Product description» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: 2 stratified guide channels, Sensor clamping strip, Electric heating sleeve 1 œ⻠SPSX 800 and 1000 (Ă 790 / Ă 850 mm) with attachment points B1/B2 (B1 to support our freshwater module or modules from other manufacturers by the universal assembly plate, B2 optionally for other modules (freshwater or solar station)» optionally for extra charge: Flange 280 x 200 x LK 245 for inpection or for the installation of a finned tube heat exchanger (SPSX-F)» Insulation: removable 100 mm polyline fleece insulation including base and lid insulation» Accessories: are on the pages from 84.
Wood burning plant /Wood chip heating
Solar heatingplant
Biomass/Biogas plant
Combined heat & power plant
Pelletheating
Special solutions such as the combination of various heat sources also allow for other applications.
E-HZG
Connection (A4)
Connection (A3)
Connection (A2)
Connection (A1)
Foot ring
Electric heating
stratified guide channels
E-HZG
B2
B2
www.huch.com I 33
Technical data
* Weight (kg) = installation weight (for version SPSX-F +13 Kg) Planning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications.
Storage type SPSX 200 300 400 500 600 800 850 1000 1000 1100 1500 2000 3000Ă=790 Ă=850
Content [Litres] 200 300 400 500 600 800 850 1000 1000 1100 1500 2000 3000
Energy efficiency class C C C C C C C C C C C C -
Heat retaining loss (with insulation)
[Watt] 83 92 102 112 121 134 138 145 145 151 168 186 -
Diameter without insulation
[mm] 550 550 600 650 700 790 790 790 850 850 1000 1100 1150
Diameter with insulation [mm] 750 750 800 850 900 990 990 990 1050 1050 1200 1300 1350
Insulation [mm] 100 100 100 100 100 100 100 100 100 100 100 100 100
Height with insulation [mm] 1070 1550 1610 1720 1831 1802 1970 2202 2000 2160 2130 2380 3130
Tilted height [mm] 1050 1530 1570 1690 1800 1780 1950 2180 2000 2165 2150 2420 3140
max. T/ max. P [°C/bar] 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3 95/3
Loading/unloading connections (A1-A4)
[Inch] for all storage tanks: Rp 1œ
Electric heating Height A3 [Inch] for all storage tanks: Rp 1œ
Sensor/controller connections Sensor clamping strip
Ventilation [Inch] for all storage tanks: Rp 1Œ
Dimensions
A1 [mm] 215 215 225 245 246 246 263 246 280 285 320 335 345
A2 [mm] 405 560 585 645 646 646 718 786 735 790 786 875 1135
A3 [mm] 595 905 945 1045 1046 1046 1173 1326 1195 1295 1253 1415 1925
A4 [mm] 785 1245 1315 1405 1496 1446 1633 1866 1650 1805 1720 1975 2715
Weight * [kg] 48 66 74 87 102 114 122 137 136 144 193 263 355
Buff
er s
tora
ge ta
nks
34 I Buffer storage tanks · Product catalogue 2021
Buffer storage tank SPSX-G / SPSX-2G
Price / Order number
Storage type SPSX-G / SPSX-2G 500 800 850 1000 1000 1100 1500 2000
Price Ă=790 Ă=850
SPSX-G without insulation [âŹ/item] - 1115,- 1154,- 1214,- 1258,- 1295,- 1661,- 2000,-
SPSX-2G without insulation [âŹ/item] - 1286,- 1324,- 1419,- 1463,- 1501,- 1867,- 2205,-
SPSX-G with fleece insulation [âŹ/item] 1476,- - - - - - - -
SPSX-2G with fleece insulation [âŹ/item] 1629,- - - - - - - -
Fleece insulation [âŹ/item] - 621,- 664,- 678,- 780,- 797,- 1088,- 1215,-
Order number
SPSX-G without insulation - 22582 22587 22592 23901 22597 22602 27955
SPSX-2G without insulation - 26000 26005 26010 26015 26021 26026 28313
SPSX-G with fleece insulation RAL 9006 48733 - - - - - - -
SPSX-2G with fleece insulation RAL 9006 48734 - - - - - - -
Fleece insulation RAL 9006 - 44955 44956 44957 44958 44959 44960 44966
In stock
Product description» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: optionally with one or two bare-tube heat exchanger, Stratified guide channels, Sensor clamping strip, Electric heating sleeve 1 œ⻠SPSX 800 and 1000 (Ă 790 / Ă 850 mm) with attachment points B1/B2 (B1 to support our freshwater module or modules from other manufacturers by the universal assembly plate, B2 optionally for other modules (freshwater or solar station))» Insulation: removable 100 mm polyline fleece insulation including base and lid insulation» Accessories: are on the pages from 84.
Special solutions such as the combination of various heat sources also allow for other applications.
Note: Illustration shows SPSX-2G.
Wood burning plant /Wood chip heating
Solar heatingplant
Biomass/Biogas plant
Combined heat & power plant
Pelletheating
Inlet flow (VL2)
Return flow (RL2)
Inlet flow (VL1)
Return flow (RL1)Connection (A1)
Connection (A2)
Connection (A3) / E-HZG
Connection (A4)
Foot ring
Stratified guide channels
www.huch.com I 35
Technical data
Storage type SPSX-G / SPSX-2G 500 800 850 1000 1000 1100 1500 2000Ă=790 Ă=850
Content [Litres] 500 800 850 1000 1000 1100 1500 2000
Energy efficiency class C C C C C C C C
Heat retaining loss(with insulation)
[Watt] 112 134 138 145 145 151 168 186
Diameter without insulation [mm] 650 790 790 790 850 850 1000 1100
Diameter with insulation [mm] 850 990 990 990 1050 1050 1200 1300
Insulation [mm] 100 100 100 100 100 100 100 100
Height with insulation [mm] 1720 1802 1970 2202 2000 2160 2130 2380
Tilted height [mm] 1690 1780 1950 2180 2000 2165 2150 2420
Heating surface top/bottom [mÂČ] 1,1 / 2,15 1,4 / 2,5 1,4 / 2,5 2,0 / 3,2 2,1 / 3,2 2,1 / 3,2 2,15 / 4,25 2,15 / 4,25
Water content WT top/bottom [Litres] 7,0 / 13,5 8,8 / 15,7 8,8 / 15,7 12,6 / 20,1 13,2 / 20,1 13,2 / 20,1 13,5 / 26,7 13,5 / 26,7
max. T/ max. P - Storage tank [°C/bar] 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3
max. T/ max. P - GWT-HZG [°C/bar] 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25
Heat exchanger (VL/RL) [Inch] G 1 A G 1 A G 1 A G 1 A G 1 A G 1 A G 1 A G 1 A
Loading/unloading connections (A1-A4)
[Inch] Rp 1œ Rp 1œ Rp 1œ Rp 1œ Rp 1œ Rp 1œ Rp 1œ Rp 1œ
Electric heating Height A3 [Inch] Rp 1œ Rp 1œ Rp 1œ Rp 1œ Rp 1œ Rp 1œ Rp 1œ Rp 1œ
Sensor/controller connections Sensor clamping strip
Thermometer connections for all storage tanks: M8 thermometer option
Ventilation [Inch] Rp 1Œ Rp 1Œ Rp 1Œ Rp 1Œ Rp 1Œ Rp 1Œ Rp 1Œ Rp 1Œ
Dimensions
A1, RL1 [mm] 245 246 263 246 280 285 320 335
A2 [mm] 645 646 718 786 735 790 786 875
VL1 [mm] 870 816 833 946 980 985 1020 1035
A3, E-HZG [mm] 1045 1046 1173 1326 1195 1295 1253 1415
RL2 only SPSX-2G [mm] 1095 1096 1223 1376 1245 1345 1303 1515
VL2 only SPSX-2G [mm] 1385 1386 1513 1806 1615 1715 1653 1865
A4 [mm] 1405 1446 1633 1866 1650 1805 1720 1975
Weight* [kg] 120/137 152/173 160/181 186/216 185/217 193/225 257/290 328/361
* Weight (kg) = installation weight. ** B1 to support our freshwater module, or modules of other manufacturers by means of our universal assembly plate, B2 optionally for other modules (freshwater or solar). Planning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications.
Buff
er s
tora
ge ta
nks
36 I Buffer storage tanks · Product catalogue 2021
Buffer storage tank PSX-ECO
Price / Order number
Connection (A4)
Connection (A3)
Connection (A2)
Connection (A1)
Foot ring
Storage type PSX-ECO 200 300 400 500 800 850 1000 1000 1500 2000 3000
Price Ă=790 Ă=850
PSX-ECO without insulation [âŹ/item] - - - - 785,- 809,- 855,- 872,- 1166,- 1552,- 4316,-
PSX-ECO with fleece insulation [âŹ/item] 849,- 972,- 1103,- 1136,- - - - - - - -
Fleece insulation [âŹ/item] - - - - 621,- 664,- 678,- 780,- 1088,- 1215,- 1340,-
Order number
PSX-ECO without insulation - - - - 15433 17569 13305 23932 13484 14417 17317
PSX-ECO with fleece insulation RAL 9006
48690 48722 48727 48735 - - - - - - -
Fleece insulation RAL 9006 - - - - 44955 44956 44957 44958 44960 44966 44973
In stock
Product description
Special solutions such as the combination of various heat sources also allow for other applications.
» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: Sensor clamping strip» optionally for extra charge: Flange 280 x 200 x LK 245 for inpection or for the installation of a finned tube heat exchanger» Insulation: removable 100 mm polyline fleece insulation including base and lid insulation» Accessories: are on the pages from 84.
Wood burning plant /Wood chip heating
Solar heatingplant
Biomass/Biogas plant
Combined heat & power plant
Pelletheating
www.huch.com I 37
Technical data
Storage type PSX-ECO 200 300 400 500 800 850 1000 1000 1500 2000 3000Ă=790 Ă=850
Content [Litres] 200 300 400 500 800 850 1000 1000 1500 2000 3000
Energy efficiency class C C C C C C C C C C -
Heat retaining loss (with insulation)
[Watt] 83 92 102 112 134 138 145 145 168 186 -
Diameter without insulation [mm] 550 550 600 650 790 790 790 850 1000 1100 1150
Diameter with insulation [mm] 750 750 800 850 990 990 990 1050 1200 1300 1350
Insulation [mm] 100 100 100 100 100 100 100 100 100 100 100
Height with insulation [mm] 1070 1550 1610 1720 1802 1970 2202 2000 2130 2380 3160
Tilted height [mm] 1050 1530 1570 1710 1780 1990 2180 2000 2150 2420 3170
max. T/ max. P - HZG [°C/bar] 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3
Loading/unloading connections (A1 - A4)
[Inch] for all storage tanks: Rp 1œ
Sensor/controller connections Sensor clamping strip
Thermometer connections for all storage tanks: M8 thermometer option
Ventilation IG [Inch] for all storage tanks: Rp 1Œ
Dimensions
A1 [mm] 215 215 225 245 246 263 246 280 320 335 375
A2 [mm] 405 560 585 645 646 718 786 735 786 875 1165
A3 [mm] 595 905 945 1045 1046 1173 1326 1195 1253 1415 1955
A4 [mm] 785 1245 1315 1405 1446 1633 1866 1650 1720 1975 2745
Weight* [kg] 46 63 71 83 110 118 132 132 189 258 349
* Weight (kg) = installation weight. Planning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications.
Insulating capsConsisting of rosette, socket cap, fleeceronde.For isolating unused 100 mm connections (Rp 1 Âœ â).
Order no: 58031 Price [âŹ/item]: 13,-
Buff
er s
tora
ge ta
nks
38 I Buffer storage tanks · Product catalogue 2021
Buffer storage tank PSX-G-ECO
Price / Order number
Storage type PSX-G-ECO 500 800 850 1000 1500 2000
Price
PSX-G-ECO without insulation [âŹ/item] - 1083,- 1115,- 1185,- 1607,- 1957,-
PSX-G-ECO with insulation [âŹ/item] 1424,- - - - - -
Fleece insulation [âŹ/item] - 621,- 664,- 678,- 1088,- 1215,-
Order number
PSX-G-ECO without insulation - 16435 17713 16440 16445 18334
PSX-G-ECO with fleece insulation RAL 9006 (only 500 l)
50560 - - - - -
Fleece insulation RAL 9006 - 44988 44990 44991 44993 44994
In stock
Product description» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: large bare-tube heat exchanger, Sensor clamping strip» Insulation: removable 100 mm polyline fleece insulation including base and lid insulation» Accessories: are on the pages from 84.
Special solutions such as the combination of various heat sources also allow for other applications.
Connection (A4)
Connection (A3)
Connection (A2)
Connection (A1)Return flow (RL)
Inlet flow (VL)
Foot ring
Wood burning plant /Wood chip heating
Solar heatingplant
Biomass/Biogas plant
Combined heat & power plant
Pelletheating
www.huch.com I 39
Technical data
* Weight (kg) = installation weightPlanning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications.
Storage type PSX-G-ECO 500 800 850 1000 1500 2000
Content [Litres] 500 800 850 1000 1500 2000
Energy efficiency class C C C C C C
Heat retaining loss(with insulation)
[Watt] 112 134 138 145 168 186
Diameter without insulation [mm] 650 790 790 790 1000 1100
Diameter with insulation [mm] 850 990 990 990 1200 1300
Insulation [mm] 100 100 100 100 100 100
Height with insulation [mm] 1720 1802 1970 2202 2130 2410
Tilted height [mm] 1710 1780 1990 2180 2150 2450
Heating surface [mÂČ] 2,5 2,5 2,5 3,2 4,25 4,25
Water content WT [Litres] 15,7 15,7 15,7 20,1 26,7 26,7
max. T/ max. P - Storage tank [°C/bar] 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3
max. T/ max. P - GWT-HZG [°C/bar] 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25
Heat exchanger (VL/RL) [Inch] AG 1 AG 1 AG 1 AG 1 AG 1 AG 1
Loading/unloading connections (A1 - A4)
[Inch] Rp 1œ Rp 1œ Rp 1œ Rp 1œ Rp 1œ Rp 1œ
Electric heating for all storage tanks: no
Sensor/controller connections Sensor clamping strip
Thermometer connections for all storage tanks: M8 thermometer option
Ventilation [Inch] Rp 1Œ Rp 1Œ Rp 1Œ Rp 1Œ Rp 1Œ Rp 1Œ
Dimensions
A1, RL [mm] 245 246 263 246 320 365
A2 [mm] 645 646 718 786 786 905
VL [mm] 870 816 833 946 1020 1065
A3 [mm] 1045 1046 1173 1326 1253 1445
A4 [mm] 1405 1446 1633 1866 1720 1985
Weight* [kg] 116 148 156 181 262 323
Buff
er s
tora
ge ta
nks
40 I Buffer storage tanks · Product catalogue 2021
Storage type PS-BHKW 500 750 1000 1500 2000
Price
PS-BHKW without insulation [âŹ/item] - 1248,- 1440,- 1926,- 2283,-
PS-BHKW with fleece insulation [âŹ/item] 1719,- - - - -
Fleece insulation [âŹ/item] - 627,- 712,- 908,- 1063,-
Order number
PS-BHKW without insulation - 49608 49616 49627 49631
PS-BHKW with fleece insulation RAL 9006 49596 - - - -
Fleece insulation RAL 9006 - 49607 49615 49624 49628
In stock
Buffer storage tank PS-BHKW
Price / Order number
Product description» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 6 bar» Technical features: 4x Flange nozzlez DN65 PN6 incl. tube bend, layer perforation plate, ventilation sleeve 1 1/4", draining sleeve 1", 6x sleeves for thermometer, sensor clamping strip» Insulation: removable 100 mm polyline fleece insulation including base and lid insulation» Accessories: are on the pages from 84
Special solutions such as the combination of various heat sources also allow for other applications.
Wood burning plant /Wood chip heating
Biomass/Biogas plant
Combined heat & power plant
Pelletheating
Connection (A2) Connection (A2)
Connection (A1) Connection (A1)
Layer perforation platesensor sleeve
Foot ring
www.huch.com I 41
Technical data
Storage type PS BHKW 500 750 1000 1500 2000
Content [Litres] 500 750 1000 1500 2000
Energy efficiency class C C C C C
Heat retaining loss (with insulation) [Watt] 112 134 145 168 186
Diameter without insulation [mm] 650 790 850 1000 1100
Diameter with insulation [mm] 850 990 1050 1200 1300
Insulation [mm] 100 100 100 100 100
Height with insulation [mm] 1749 1793 2044 2207 2374
Tilted height [mm] 1715 1775 2010 2205 2480
max. T/ max. P - HZG [°C/bar] 95 / 6 95 / 6 95 / 6 95 / 6 95 / 6
Sensor/controller connections [Inch] Rp œ Rp œ Rp œ Rp œ Rp œ
Thermometer connections [Inch] Rp œ Rp œ Rp œ Rp œ Rp œ
Dimensions
A1 [mm] 270 300 313 335 352
A2 [mm] 1410 1420 1663 1785 1952
Weight* [kg] 117 163 179 285 356
* Weight (kg) = installation weightPlanning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications.
Buff
er s
tora
ge ta
nks
42 I Buffer storage tanks · Product catalogue 2021
Gross-Buffer storage tank GPS
Price / Order number
Product description
Special solutions such as the combination of various heat sources also allow for other applications.
» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: Storage tank with feets, 6x 2" Connection sleeves (two with tube bend), 3x 1/2" sensor sleeves, ventilation sleeve 2", Draining sleeve 2"» Insulation: removable 100 mm polyline fleece insulation including base and lid insulation» Accessories: are on the pages from 84
Storage type GPS 2000 3000 3000 4000 5000 6000 7000 8000 9000 10000
Price Ă=1250 Ă=1600
GPS without insulation [âŹ/item] 1943,- 2064,- 2798,- 3217,- 3617,- 4140,- 4396,- 4653,- 4909,- 5404,-
Fleece insulation [âŹ/item] 1063,- 1434,- 1519,- 1797,- 2146,- 2318,- 2500,- 2742,- 2980,- 3262,-
Order number
GPS without insulation 50958 50949 50945 50941 50937 50933 50928 50923 50918 50844
Fleece insulation RAL 9006 50991 50992 50993 50994 50995 50996 50997 50998 50999 51000
In stock
Direct heating system
Wood burning plant /Wood chip heating
Biomass/Biogas plant
Combined heat & power plant
Ventilation
Draining
Connection (A1)
Connection (A2)
Connection (A3)
Feets
Hoisting eye
sensorsleeve
www.huch.com I 43
Technical data
* Weight (kg) = installation weightPlanning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications.
Storage type GPS 2000 3000 3000 4000 5000 6000 7000 8000 9000 10000Ă=1250 Ă=1600
Content [Litres] 2000 3000 3000 4000 5000 6000 7000 8000 9000 10000
Energy efficiency class C - - - - - - - - -
Heat retaining loss (with insulation)
[Watt] 186 - - - - - - - - -
Diameter with insulation [mm] 1250 1250 1600 1600 1600 1600 1600 1600 1600 1600
Diameter with insulation [mm] 1450 1450 1800 1800 1800 1800 1800 1800 1800 1800
Insulation [mm] 100 100 100 100 100 100 100 100 100 100
Height with insulation [mm] 2125 2865 2080 2580 3020 3570 4070 4570 5010 5520
Tilted height [mm] 2275 3015 2250 2750 3150 3650 4150 4650 5150 5650
max. T/ max. P - HZG [°C/bar] 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3 95/ 3
Loading/unloading connections (A1 - A3)
[Inch] Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2
Sensor/controller connections
[Inch] Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ
Ventilation IG [Inch] Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 2
Draining [Inch] G 2 G 2 G 2 G 2 G 2 G 2 G 2 G 2 G 2 G 2
Dimensions
A1 [mm] 632 632 710 710 710 710 710 710 710 710
A2 [mm] 1137 1507 1115 1365 1585 1860 2110 2360 2505 2835
A3 [mm] 1642 2382 1520 2020 2460 3010 3510 4010 4450 4960
Draining [mm] 174 174 173 173 173 173 173 173 173 173
Weight* [kg] 271 339 407 465 516 581 640 697 751 810
Buff
er s
tora
ge ta
nks
44 I System products · Product catalogue 2021
© panthermedia.net / Ingrid Balabanova
www.huch.com I 45
Almost 90 % of the energy in private households is needed for hot water generation and heating. Thanks to individual components adapted to each other, we can provide you with an all-round, care-free package for an up-to-date and energy-efficient heating system. For you, this means the best-possible energy utilization and maximum fail-safe operations from the start.
System products for our Huch storage tanksGet fit for the future.
Hygienic and efficientDue to the continuous flow of drinking water, no legi-onella.
Optimal temperature stratificationLayer perforation plate and inflow damper ensure that temperature swirls in the storage tank are reduced.
Connection sleeve2" connection sleeves for a high transmission capacity (flow rates up to 2.5 m3 / h). The Huch standard con-nection sleeves are 50 mm length. Connections that are not used is covered with the insulated.
Manifold connection scopeOur buffer storage tanks have a host of connections. This makes possible an optimum system attachment for the most varied of applications.
Flexible positioning of the temperature sensorsSensor clamping strips allow the temperature sensor to be positioned at will. As a result, the Huch storage tanks are suitable for many application fields.
Innovative highly efficient storage tank insulationThe high-grade Polyline© fleece insulation incl. a 100 mm lid and a 50 mm base insulation reduces heat loss by 10-15 % over soft foam.
Quality features
Buffer storage tank PSFW-G is shown in the illustration.
1
1
2
2
3
4
4
5
5
66
Syst
em p
rodu
cts
46 I System products · Product catalogue 2021
Buffer storage tank PSFW /-G
Price / Order number500 800 1000
Price
PSFW without insulation [âŹ/item] 893,- 1025,- 1191,-
PSFW-G without insulation [âŹ/item] 1066,- 1283,- 1451,-
Polyline fleece insulation RAL 9006 [âŹ/item] 557,- 621,- 678,-
Order number
PSFW without insulation 57161 57164 57167
PSFW-G without insulation 56225 55781 56184
Polyline fleece insulation RAL 9006 56912 56913 56914
In stock
Product description
Suitable for:
Special solutions such as the combination of various heat sources also allow for other applications.
» Material: S235JR+N steel, internal uncoated, external primer coat» Compressive strenght: 3 bar» Technical features: optionally with one bare-tube heat exchanger bottom (-G), sensor clamping strip, 2x electric heating sleeve 1 Âœâ, layer perforation plate, inflow damper, attachment points and connection sleeves for the freshwater station fresh easy 30 / fresh hydro 40, 2â sleeves» Insulation: removable 100 mm polyline fleece insulation including base and lid insulation
Heater
Drinking water
Note: Illustration shows the PSFW-G with the freshwater station fresh easy 30.
FRIWA
Inlet flow E (VLE)
Inlet flow S (VLS)
Inlet flow B (VLB)
Cold water (KW)Hot water (WW)
Return flow S (RLS)
Return flow E (RLE1)
Return flow E (RLE2)
Return flow B (RLB) /Inlet flow E (VLE)
Electric heating (E-HZG2)
Electric heating (E-HZG1)
Return flow WP (RL1WP)
Return flow WP (RL2WP)
Inlet flow WP (VL1WP)Connection option (VB4)
Connection option (VB3)
Connection option (VB2)
Connection option (VB1)
Inlet flow WP (VL2WP)
Foot ring
Hoisting eye
Heating pumpOil heating plant Gas plantSolar heating
plant
www.huch.com I 47
Technical data
Storage type PSFW / -G 500 800 1000
Content [Litres] 500 800 1000
Energy efficiency class
Heat retaining loss with insulation [Watt] 112 135 145
Diameter without insulation [mm] 650 750 790
Diameter with insulation [mm] 850 950 990
Insulation [mm] 100 100 100
Height with insulation [mm] 1850 2010 2220
Tilted height [mm] 1820 2000 2200
Heating surface bottom (-G) [mmÂČ] 1,7 2,5 3,2
Water content WT bottom (-G) [Litres] 10,7 15,7 20,1
max. T/ max. P - Storage tank [°C/bar] 95/3 95/3 95/3
max. T/ max. P - GWT (-G) [°C/bar] 110/25 110/25 110/25
Heat exchanger all AG (-G) (VL/RL) [Inch] G 1 G 1 G 1
Loading/unloading connections all IG (HZG) [Inch] Rp 1œ Rp 1œ Rp 1œ
Loading/unloading connections all IG (WP) [Inch] Rp 2 Rp 2 Rp 2
Electric heating [Inch] Rp 1œ Rp 1œ Rp 1œ
Sensor/controller connections Sensor clamping strip
Ventilation [Inch] Rp Ÿ Rp Ÿ Rp Ÿ
Dimensions 500 800 1000
RL2WP, RLS (only -G) [mm] 256 286 288
E-HZG 1 [mm] 320 340 350
VB1 [mm] 270 350 350
RLE2 [mm] 640 660 710
VB2 [mm] 720 725 725
RLE1 [mm] 830 920 1000
VLS (only -G) [mm] 727 936 988
VL2WP [mm] 850 970 1070
RLB/VLE [mm] 940 1060 1160
E-HZG2/RL1WP [mm] 1050 1170 1270
VB3 [mm] 1150 1170 1170
VLE [mm] 1160 1340 1420
VLB [mm] 1270 1450 1530
VL1WP [mm] 1521 1650 1860
VB4 [mm] 1540 1680 1900
FRIWA [mm] 1552 1681 1891
Weight PSFW/PSFW-G * [kg] 84/114 105/149 122/174
* Weight (kg) = installation weightPlanning and setting up the heating system on the basis of the technical guidelines to avoid oxygen-induced corrosion in keeping with VDI and DIN specifications.
Syst
em p
rodu
cts
48 I System products · Product catalogue 2021
Freshwater station fresh easy 30 / fresh hydro 40
Product description
Price / Order number
» Compact and ready-to-connect group of taps» Deployment in combination with our buffer storage tank PSFW /-G» Prevention of calcification through admixture from the central zone» Optionally with or without circulation pump» Manifold possibilities for deployment detached houses and apartment blocks» For both new building construction and existing building revamping» also suitable for wall mounting (piping on site)
Fresh easy 30:» Filling rate 30 l/min
Fresh hydro 40:» Filling rate 40 l/min» 4-way cascading up to 160 l / min possible» Cascade valves
Note: Please refer to the buffer storage tank column for the specification on our buffer storage tanks.
Technical dataFreshwater modul Fresh easy 30 Fresh hydro 40
Regulation type thermostatic electronically
Connections primary AG [Inch] G1 G1
Connections secondary IG [Inch] G1 G1
Circulation IG [Inch] G œ G œ
max. T/ max. P - TW [°C/bar] 95/10 95/10
max. T/ max. P - HZG [°C/bar] 95/3 95/3
WW output (KW 10°C / WW 45°C)inlet flow temperature 70°C
[l/min] 30 40
Medium primary /secondary Heater water / Drinking water Heater water / Drinking water
Heat exchanger (stainless steel, copper-soldered) 29 Platten 41 Platten
Dimensions Easy 30 Hydro 40
Dimensions B x H x T (incl. Insulation) [mm] 400 x 600 x 302 400 x 600 x 302
Fresh easy 30 Fresh hydro 40
Price
Freshwater station without circulation [âŹ/item] 1503,- 2231,-
Freshwater station with circulation [âŹ/item] 1947,- 2677,-
Order number
Freshwater station without circulation 57498 57104
Freshwater station with circulation 58257 58256
www.huch.com I 49
Schematic diagram PSFW-G & freshwater station
FRIWA
E-HZG2
Hea
t gen
erat
or
E-HZG1
VB3
VB4
WW KW
VB2
VB1
VB = connection option for additional storage tanks
Example: Boiler (oil heating plant, gas plant or similar) in combination with solar
Example: Heat pump in combination with solar
FRIWA
E-HZG2
E-HZG1
VB3
VB4
VB2
VB1
VB = connection option for additional storage tanks
Hea
t pum
p
WW KW
Schematic diagram â relevant standards and regulations must be observed!
Syst
em p
rodu
cts
50 I Combined storage tanks · Product catalogue 2021
© iStock
Huch combined storage tankThe combined storage tank series - space-saving solutions for your requirements.Combined storage tanks provide space-saving solutions for both domestic water generation and heating. Integrated stainless steel corrugated tube system (5 mÂČ or 8 mÂČ) for domestic water heating.
www.huch.com I 51
Connection scheme
Schematic diagram â relevant standards and regulations must be observed!
6
1
4
3
2
7
5
Quality features
High-grade bare-tube heat exchangersThanks to a special heat exchanger design and arrangement a high extraction grade of up to 96% is achieved.
Optimum temperature stratificationStratification guiding channels and baffle plates ensure that temperature swirls in the storage tank are reduced.
Connection stubsOur connection stubs are a standard 50 mm in length. The fleece insulation thus insulates any non-used connections. This cuts radiation losses and an improved energy efficiency is achieved by the storage tank.
Manifold connection scopeOur combined storage tanks have a host of connections. This makes possible an optimum system attachment for the most varied of applications.
Domestic water-suitedHygienically correct domestic water heating thanks to high-grade quality stainless steel.
Flexible positioning of the temperature sensorsSensor clamping strips allow the temperature sensor to be positioned at will. As a result, the Huch storage tanks are suitable for many application fields.
Innovative highly efficient storage tank insulationThe high-grade Polyline© fleece insulation incl. a 100 mm lid and a 50 mm base insulation reduces heat loss by 10-15 % over soft foam.
1
2
3
4
5
6
7
The WKS-2G combined storgae tank is shown in the illustration.
Cold water
Holzkamin mit Wassertasche Wall-huning heater
Com
bine
d st
orag
e ta
nks
52 I Combined storage tanks · Product catalogue 2021
Storage type WKS-WP-0/-1/-2 600 800 1000 1250 1500
Price
WKS-WP without insulation [âŹ/item] 1645,- 1747,- 1895,- 2021,- 2146,-
WKS-WP-1 without insulation [âŹ/item] 1831,- 1934,- 2060,- 2281,- 2475,-
WKS-WP-2 without insulation [âŹ/item] 1975,- 2100,- 2352,- 2614,- 2877,-
Fleece insulation [âŹ/item] 656,- 678,- 715,- 884,- 1184,-
Order number
WKS-WP without insulation 47163 47187 47198 47117 47201
WKS-WP-1 without insulation 47181 47188 47199 47105 47205
WKS-WP-2 without insulation 47182 47189 47200 47089 47206
Fleece insulation RAL 9006 45625 45598 45649 47085 45675
In stock
Combined storage tank for heat pumps WKS-WP (-0/-1/-2)
Product description
Price / Order number
Special solutions such as the combination of various heat sources also allow for other applications.
» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: integated drinking water heater as 6,5 m2 stainless steel corrugated pipe system, optionally with up to two additional solar heat exchangers (-0, -1, -2), electric heating sleeve (Rp 1 Âœâ), 2â connection sleeves, sensor clamping strip, special inlet channels, inlet bends» Insulation: removable 120 mm polyline fleece insulation including base and lid insulation» Accessories: are on the pages from 84
In cooperation and tested by Kermi.
Heating pumpSolar heating plant
Wood burning plant /Wood chip heating
Biomass/Biogas plant
Combined heat and power plant
Hot water (WW)
Cold water (KW)
Inlet flow (VL2)
Return flow (RL2)
Inlet flow (VL1)E-HZG
Return flow (RL1)
Connection (A1)
Connection (A3)
Connection (A2)
Connection (A4)
Ventilation
Foot ring
www.huch.com I 53
Storage type WKS-WP-0/-1/-2 600 800 1000 1250 1500
Content (HZG/WW) [Litres] 600 800 1000 1250 1500
Content of standby unit [Litres] 274 361 406 527 641
Energy efficiency class C C C C C
Heat retaining loss [Watt] 119 131 142 151 165
Diameter without insulation [mm] 700 790 790 900 1000
Diameter with insulation [mm] 940 1030 1030 1140 1240
Insulation [mm] 120 120 120 120 120
Height mit fleece insulation [mm] 1960 1980 2230 2280 2200
Tilted height without insulation [mm] 1950 1960 2250 2280 2220
Heating surface top/bottom [mÂČ] 1,3 / 2,0 1,4 / 2,5 2,0 / 3,2 2,1 / 3,2 2,15 / 4,25
Heating surface TW corrugate pipe [mÂČ] 6,5 6,5 6,5 6,5 6,5
Water content GWT top/bottom [Litres] 8,2 / 12,5 8,8 / 15,7 12,5 / 20,1 13,2 / 20,1 13,5 / 26,7
Water content TW corrugate pipe [Litres] 35 35 35 35 35
NL number* according to DIN 4708 2,2 2,5 3,2 3,5 3,8
10-min peak tap volume at standby unit temp.** 52°C
[Litres] 125 160 167 181 215
10-min peak tap volume at standby unit temp.** 65°C
[Litres] 170 220 258 325 360
10-min peak tap volume of 6,5 m2 at storage tank temp.*** 65°C
[Litres] 242 337 385 420 475
theoretical continuous output 6,5mÂČ for all storage tanks: 2500 l/h heating output 105 kW
max. T/ max. P - WT-HZG [°C/bar] 110 / 25 110 / 25 110 / 25 110 /25 110 / 25
max. T/ max. P - Buffer storage tank [°C/bar] 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3
max. D p Storage tank / TW corrugate pipe [bar] 6 6 6 6 6
Cold water / hot water AG (KW/WW) [Inch] stainless steel pipe G 1
Heat exchanger all AG (VL/RL) [Inch] G 1 G 1 G 1 G1 G 1
Loading/unloading connections IG (A1-A4) [Inch] Rp 2 Rp 2 Rp 2 Rp 2 Rp 2
Electric heating IG (E-HZG) / max. immersion depth
[Zoll/mm] Rp 1 œ / 550 Rp 1 œ / 620 Rp 1 œ / 620 Rp 1 œ / 700 Rp 1 œ / 750
Sensor/controller connections Sensor clamping strip
Dimensions 600 800 1000 1250 1500
A1 [mm] 246 246 246 285 320
RL 1 (only -1, -2) [mm] 356 356 346 385 420
A2 [mm] 858 858 1011 1050 970
VL 1 (only -1, -2) [mm] 836 836 946 985 1020
A3 [mm] 1202 1202 1396 1435 1390
RL 2 (only -2) [mm] 1121 1121 1300 1339 1301
A4 [mm] 1581 1581 1866 1905 1790
VL 2 (only -2) [mm] 1461 1411 1730 1729 1651
E-HZG [mm] 918 918 1041 1080 1185
Cold water / hot water (drinking water) [mm] 246 / 1581 246 / 1581 246 / 1831 285 / 1870 320 / 1765
Weight WKS-WP-0/-1/-2 **** [kg] 152 / 165 / 185 171 / 185 / 205 198 / 215 / 235 256 / 272 / 293 289 / 305 / 325
Technical data
* In order to achieve the specified NL number, the boiler out. ** Standby unit up to A3; continuous output (l/h) = 10 min. Peak consumption x 6 when boiler output > continuous out-put. *** Storage unit loaded between connection A1 and A4; continuous output (l/h) = 10 min. peak tap volume x 6 for boiler output > continuous output. **** for SKSW circulation via T-piece in WW outflow possible. ***** Weight (kg) = installation weight. Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water.
Com
bine
d st
orag
e ta
nks
54 I Combined storage tanks · Product catalogue 2021
Typ - Combined storage tank WKS /-G / -2G 600 800 1000 1250 1500PriceWKS without insulation [âŹ/item] 2120,- 2147,- 2171,- 2568,- 2657,-WKS-G without insulation [âŹ/item] 2302,- 2423,- 2481,- 2882,- 2903,-WKS-2G without insulation [âŹ/item] 2473,- 2595,- 3116,- 3126,- 3140,-Fleece insulation [âŹ/item] 624,- 645,- 681,- 843,- 1127,-Order numberWKS without insulation 36701 36706 36711 36718 36723WKS-G without insulation 35201 35205 35210 35214 35218WKS-2G without insulation 35135 35060 35083 35093 35123Fleece insulation RAL 9006 42266 41259 41260 42268 42269In stock
Combined storage tank WKS / WKS-G / WKS-2G
» Material: S235JR+N steel, internal uncoated, external primer coat » Compressive strenght: 3 bar» Technical features: integated drinking water heater as 5 m2 stainless steel corrugated pipe system (firmly welded), optionally with up to two additional solar heat exchangers (-0, -1, -2), electric heating sleeve (Rp 1 Âœâ)» Connections: WW/KW connection by side, buffer storage unit connections as Rp 1 œ⻠Insulation: removable 100 mm polyline fleece insulation including base and lid insulation » Accessories: are on the pages from 84
Product description
Price / Order number
Special solutions such as the combination of various heat sources also allow for other applications.
Solar heating plant
Wood burning plant /Wood chip heating
Biomass/Biogas plant
Combined heat and power plant
Hot water (WW)
Cold water (KW)
Inlet flow (VL2)
Return flow (RL2)
Inlet flow (VL1)
E-HZG
Connection (A1)
Connection (A3)
Connection (A2)
Connection (A4)
Ventilation
Foot ring
Return flow (RL1)
www.huch.com I 55
Typ - Combined storage tank WKS /-G / -2G 600 800 1000 1250 1500
Content [Litres] 600 800 1000 1250 1500
Energy efficiency class C C C C C
Heat retaining loss (with insulation) [Watt] 121 134 145 154 168
Diameter without insulation [mm] 700 790 790 900 1000
Diameter with insulation [mm] 900 990 990 1100 1200
Insulation [mm] 100 100 100 100 100
Height with insulation [mm] 1849 1797 2225 2243 2160
Tilted height [mm] 1820 1820 2200 2250 2150
Heating surface top/bottom [mÂČ] 1,3/2,0 1,4/2,5 2,0/3,2 2,1/3,2 2,15/4,25
Heating surface TW corrugate pipe [mÂČ] 5 5 5 5 5
Water content WT top/bottom [Litres] 8,2/12,5 8,8/15,7 12,5/20,1 13,2/20,1 13,5/26,7
WasserContents TW corrugate pipe [Litres] 27 27 27 27 27
NL number* according to DIN 4708 2,2 2,5 3,2 3,5 3,8
10-min peak tap volume as standby unit temp.** 52°C
[Litres] 125 160 167 181 215
10-min peak tap volume as standby unit temp.** 65°C
[Litres] 170 220 258 325 360
10-min peak tap volume as standby unit temp.*** 65°C
[Litres] 230 324 370 403 460
theoretical continuous output 5mÂČ For all storage tanks: 1950 l/h heating output 80 kW
max. T/ max. P - WT-HZG [°C/bar] 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25
max. T/ max. P - Buffer storage tank [°C/bar] 95 / 3 95 / 3 95 / 3 95 / 3 95 / 3
max. D p Storage tank / TW corrugate pipe [bar] 6 6 6 6 6
Cold water / hot water (KW/WW) For all storage tanks: stainless steel corrugate pipe 28 x 1,5 for Press fitting
Heat exchanger all AG (VL/RL) [Inch] G 1 G 1 G 1 G 1 G 1
Loading/unloading connections IG (A1-A4) [Inch] Rp 1 1/2 Rp 1 1/2 Rp 1 1/2 Rp 1 1/2 Rp 1 1/2
Electric heating IG (E-HZG) [Inch] Rp 1 1/2 Rp 1 1/2 Rp 1 1/2 Rp 1 1/2 Rp 1 1/2
immersion depth Electric heating 550 620 620 700 750
Sensor/controller connections Sensor clamping strip
Dimensions
A1 [mm] 246 246 246 288 320
RL 1 (only -G, -2G) [mm] 246 246 246 288 320
A2 [mm] 646 646 786 812 786
VL 1 (only -G, -2G) [mm] 786 816 946 888 1020
RL 2 (only -2G) [mm] 1096 1126 1376 1413 1310
A3 [mm] 1046 1046 1326 1336 1253
A4 [mm] 1496 1466 1866 1858 1720
VL 2 (only -2G) [mm] 1436 1416 1806 1798 1660
E-HZG [mm] 926 896 1101 1186 1123
Cold water / hot water (drinking water) [mm] 223 / 1496 223 / 1466 223 / 1866 265 / 1858 297 / 1720
Weight WKS /-G/-2G **** [kg] 125 / 161 / 181 144 / 182 / 202 164 / 213 / 233 249 / 269 / 289 283 / 303 / 323
Technical data
* In order to achieve the specified NL number, the boiler out. ** Standby unit up to A3; continuous output (l/h) = 10 min. Peak consumption x 6 when boiler output > continuous out-put. *** Storage unit loaded between connection A1 and A4; continuous output (l/h) = 10 min. peak tap volume x 6 for boiler output > continuous output. **** for SKSW circulation via T-piece in WW outflow possible. ***** Weight (kg) = installation weight. Pay attention to the applicable DIN and DVGW specifications when connecting up the domestic water.
Com
bine
d st
orag
e ta
nks
56 I Stainless steel storage tanks · Product catalogue 2021
© iStock
www.huch.com I 57
Quality features
Huch Stainless steel storage tankHigh-grade storage solutionsOur stainless steel storage tanks are designed for the hygienic hot water generation of domestic water and/or heating. Stainless steel storage tanks have long service lives and are practically maintenance-free.
High-grade bare-tube heat exchangersThanks to a special heat exchanger design and arrangement a high extraction grade of up to 96% is achieved.
Domestic water-suitedHygienically correct domestic water heating thanks to high-grade quality stainless steel.
Innovative highly efficient storage tank insulationThe high-grade Polyline© fleece insulation incl. a 100 mm lid and a 50 mm base insulation reduces heat loss by 10-15 %.
PU rigid foam insulation - 50 mm high-grade polyurethane foam firmly wraps up the vessels in foam. No chimney effect develops and the insulation has excellent insulating properties.
1
2
3
The HSS stainles steel solar storage tank is shown in the illustration.
1
3
2
Stai
nles
s st
eel s
tora
ge ta
nks
58 I Stainless steel storage tanks · Product catalogue 2021
Stainless steel solar storage tank HSS
Price / Order number
Storage type HSS 200 300 400 500 750 1000
Price
HSS with insulation RAL 9006 [âŹ/item] 3725,- 4620,- 5245,- 5508,- - -
HSS without insulation [âŹ/item] - - - - 6875,- 7880,-
Fleece insulation RAL 9006 [âŹ/item] - - - - 680,- 810,-
Order number
HSS with insulation RAL 9006 56306 56307 56312 56313 - -
HSS without insulation - - - - 13332 13060
Fleece insulation RAL 9006 - - - - 36890 35830
In stock
Product description» Material: Stainless steel 1.4571» Compressive strenght: 10 bar» Technical features: two large bare-tube heat exchanger, inspection flange 180 x 110 x LK 150» Insulation: removable 100 mm polyline-fleece insulation including base and lid insulation » until 5.000 Litres on request» Accessories: are on the pages from 84
Special solutions such as the combination of various heat sources also allow for other applications.
Circulation (Z)
Return flow (RL1)
Inlet flow (VL2)
Hot water (WW)
Inlet flow (VL1)
Return flow (RL2)
Cold water (KW)
Inspection flange with optional connection for additional heat sources (RFL)
Foot ring
Electric heating
Sensor/controller connections
Sensor/controller connections
Sensor/controller connections
Pellet heating
Condensing power plant
Oil heating plant
Gas plant
Solar heating plant
Wood burning plant /Wood chip heating
Biomass/Biogas plant
Combined heat and power plant
www.huch.com I 59
Storage type HSS 200 300 400 500 750 1000
Content [Litres] 200 300 400 500 750 1000
Energy efficiency class C C C C C C
Heat retaining loss (with insulation)
[Watt] 83 92 102 112 131 145
Diameter without insulation [mm] 500 500 600 600 750 850
Diameter with insulation [mm] 700 700 800 800 950 1050
Insulation [mm] 100 100 100 100 100 100
Height with insulation [mm] 1445 1695 1740 1990 2075 2116
Tilted height [mm] 1420 1670 1730 1970 2070 2130
Heating surface top/bottom [mÂČ] 0,9 / 0,9 0,9 / 1,4 0,9 / 1,8 0,9 / 1,8 1,4 / 2,4 1,6 / 2,8
Water content WT top/bottom [Litres] 3,0 / 3,0 4,7 / 7,3 6,2 / 12,5 6,2 / 12,5 9,7 / 16,6 11,1 / 19,5
Flow rate WT top/bottom [mÂł/h] 0,8 / 1,65 1,3 / 2,58 1,4 / 2,95 1,6 / 3,26 2,06 / 4,01 2,3 / 4,8
Pressure loss WT top/bottom [mbar] 160 / 580 40 / 190 15 / 90 15 / 105 35 / 200 50 / 320
NL number top/bottom * according to DIN 4708
2 / 4 3 / 12 3 / 20 4 / 23 10 / 35 14 / 46
Continuous output top/bottom DIN 4708 ( 10°/80°/45°)
[l/h](kW)
476 (19,4) / 978 (39,8)
784 (31,9) / 1522 (62,0)
820 (33,4) / 1743 (71,0)
943 (38,4) / 1924 (78,3)
1215 (49,5) / 2413 (98,2)
1348 (54,9) / 2846 (115,8)
max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10
max. T/ max. P - HZG [°C/bar] 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25
Cold water / hot water (KW/WW) [Inch] Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 œ Rp 1 œ
Circulation (Z) [Inch] Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ
Heat exchanger all AG (VL/RL) [Inch] G 1 G 1 Œ G 1 œ G 1 œ G 1 œ G 1 œ
Electric heating [Inch] Rp 1 œ Rp 1 œ Rp 1 œ Rp 1 œ Rp 1 œ Rp 1 œ
Nominal width of inspection flange (RFL) for all storage tanks: DN 110
Sensor/controller connections [Inch] for all storage tanks: Rp œ
Thermometer connections [Inch] Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ
Dimensions
KW [mm] 65 65 70 70 80 70
RL 1 [mm] 305 305 330 330 380 405
VL 1 [mm] 605 795 890 890 940 1005
Z / E-HZG [mm] 685 870 975 975 1025 1140
RL 2 [mm] 765 945 1055 1110 1115 1240
VL 2 [mm] 1065 1260 1325 1380 1430 1640
WW [mm] 1145 1375 1420 1670 1720 1745
Weight [kg] 75 100 115 120 185 210
Maintenance accessories HSS 200 300 400 500 750 1000
Stainless steel-blind flange with conn. sleeve 1 œ"
[âŹ/item]Order number
200,-12539
200,-12539
200,-12539
200,-12539
200,-12539
200,-12539
Flange seal [âŹ/item]Order number
26,-38777
26,-38777
26,-38777
26,-38777
26,-38777
26,-38777
Technical data
* In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output.
Stai
nles
s st
eel s
tora
ge ta
nks
60 I Stainless steel storage tanks · Product catalogue 2021
Stainless steel domestic water storage tank HBS
Price / Order number
Storage type HBS 150 200 300 400 500 750 1000
Price
HBS with fleece insulation RAL 9006 [âŹ/item] 3073,- 3287,- 3841,- 4450,- 4709,- - -
HBS without fleece insulation [âŹ/item] - - - - - 5868,- 6997,-
Fleece insulation RAL 9006 [âŹ/item] - - - - - 680,- 810,-
Order number
HBS with fleece insulation RAL 9006 56314 56315 56316 56317 56318 - -
HBS without fleece insulation - - - - - 12568 12679
Fleece insulation RAL 9006 - - - - - 36890 35830
In stock
Product description
Special solutions such as the combination of various heat sources also allow for other applications.
» Material: Stainless steel 1.4571» Compressive strenght: 10 bar» Technical features: large bare-tube heat exchanger, inspection flange 180 x 110 x LK 150» Insulation: removable 100 mm polyline-fleece insulation including base and lid insulation » until 5.000 Litres on request» Accessories: are on the pages from 84
Circulation (Z)
Return flow (RL1)
Hot water (WW)
Inlet flow (VL1)
Cold water (KW)
Inspection flange with optional connection for additional heat sources (RFL)
Foot ring
Electric heating
Sensor/controller connections
Sensor/controller connections
Pellet heating
Condensing power plant
Oil heating plant
Gas plant
Wood burning plant /Wood chip heating
Biomass/Biogas plant
Combined heat and power plant
www.huch.com I 61
Storage type HBS 150 200 300 400 500 750 1000
Content [Litres] 150 200 300 400 500 750 1000
Energy efficiency class C C C C C C C
Heat retaining loss (with insulation)
[Watt] 74 83 92 102 112 131 145
Diameter without insulation [mm] 400 500 500 600 600 750 850
Diameter with insulation [mm] 600 700 700 800 800 950 1050
Insulation [mm] 100 100 100 100 100 100 100
Height with insulation [mm] 1396 1445 1695 1740 1990 2075 2116
Tilted height [mm] 1360 1420 1670 1730 1970 2070 2130
Heating surface [mÂČ] 0,9 0,9 1,4 1,8 1,8 2,4 2,8
Water content WT [Litres] 3,0 3,0 7,3 12,5 12,5 16,6 19,5
Flow rate WT [mÂł/h] 1,6 1,65 2,58 2,95 3,26 4,01 4,8
Pressure loss WT [mbar] 530 580 190 90 105 200 320
NL number* according to DIN 4708
2 4 12 20 23 35 46
Continuous output DIN 4708 (10°/80°/45°)
[l/h](kW)
926 (37,7)
978(39,8)
1522(62,0)
1743(71,0)
1924(78,3)
2413(98,2)
2846(115,9)
max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10
max. T/ max. P - HZG [°C/bar] 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25 110 / 25
Cold water/hot water (KW/WW) [Inch] Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 œ Rp 1 œ
Circulation (Z) [Inch] Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ
Heat exchanger all AG (VL/RL) [Inch] G 1 G 1 G 1 Œ G 1 œ G 1 œ G 1 œ G 1 œ
Electric heating [Inch] for all storage tanks: Rp 1 œ
Nominal width of inspection flange (RFL) for all storage tanks: DN 110
Sensor/controller connections [Inch] for all storage tanks: Rp œ
Thermometer connections [Inch] Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ
Dimensions
KW [mm] 65 65 65 70 70 80 70
RL [mm] 260 305 305 330 330 380 405
VL [mm] 685 605 795 890 890 940 1005
Z / E-HZG [mm] 760 685 870 975 975 1025 1140
WW [mm] 1130 1145 1375 1420 1670 1720 1745
Weight [kg] 50 65 88 103 108 168 190
Maintenance accessories HBS 150 200 300 400 500 750 1000
Stainless steel-blind flange with conn. sleeve 1 œ"
[âŹ/item]Order number
200,-12539
200,-12539
200,-12539
200,-12539
200,-12539
200,-12539
200,-12539
Flange seal [âŹ/item]Order number
26,-38777
26,-38777
26,-38777
26,-38777
26,-38777
26,-38777
26,-38777
Technical data
* In order to achieve the specified NL number, the boiler output must be higher than the specified continuous output.
Stai
nles
s st
eel s
tora
ge ta
nks
62 I Stainless steel storage tanks · Product catalogue 2021
Stainless steel buffer storage tank HPS
Price / Order number
Storage type HPS 150 200 300 400 500 750 1000
Price
HPS with fleece insulation RAL 9006 [âŹ/item] 2666,- 3024,- 3293,- 3743,- 4034,- - -
HPS without fleece insulation [âŹ/item] - - - - - 5135,- 5969,-
Fleece insulation RAL 9006 [âŹ/item] - - - - - 680,- 810,-
Order number
HPS with fleece insulation RAL 9006 56335 56337 56338 56339 56344 - -
HPS without fleece insulation - - - - - 12438 12567
Fleece insulation RAL 9006 - - - - - 36915 36589
In stock
Product description
Special solutions such as the combination of various heat sources also allow for other applications.
» Material: Stainless steel 1.4571» Compressive strenght: 10 bar» Technical features: inspection flange 180 x 110 x LK 150» Insulation: removable 100 mm polyline-fleece insulation including base and lid insulation » until 5.000 Litres on request» Accessories: are on the pages from 84» this storage tank can by used as a buffer storage tank or as a domestic water storage tank with a external heat exchanger
Circulation (Z)
Loading connection (A1)
Sensor/controller connections (F3)
Sensor/controller connections (F1)
Sensor/controller connections (F2)
Hot water (WW)
Cold water (KW)
Inspection flange with optional connection for additional heat sources
(RFL)
Direct heating systemWood burning plant /Wood chip heating
Biomass/Biogas plant
Combined heat and power plant
www.huch.com I 63
Technical data
Storage type HPS 150 200 300 400 500 750 1000
Content [Litres] 150 200 300 400 500 750 1000
Energy efficiency class C C C C C C C
Heat retaining loss (with insulation)
[Watt] 74 83 92 102 112 131 145
Diameter without insulation [mm] 500 500 500 600 600 750 850
Diameter with insulation [mm] 700 700 700 800 800 950 1050
Insulation [mm] 100 100 100 100 100 100 100
Height with insulation [mm] 1070 1420 1670 1700 1960 2045 2130
Tilted height [mm] 1015 1380 1625 1670 1920 2015 2080
max. T/ max. P - TW [°C/bar] 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10 95 / 10
Cold water/hot water (KW/WW) [Inch] Rp 1 Œ Rp 1 Œ Rp 1 Œ Rp 1 œ Rp 1 œ Rp 2 Rp 2
Circulation (Z) [Inch] Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ
Loading connection (A1) [Inch] Rp 1 Œ Rp 1 Œ Rp 1 Œ Rp 1 œ Rp 1 œ Rp 2 Rp 2
Electric heating for all storage tanks: via inspection flange
Nominal width of inspection flange (RFL)
for all storage tanks: DN 110
Sensor/controller connections (F1-F3)
[Inch] Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ
Thermometer connections (F1-F3)
[Inch] Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ
Dimensions
KW [mm] 65 65 65 65 65 80 80
Z [mm] 590 600 850 870 1120 1165 1200
A1 [mm] 680 1000 1250 1270 1520 1565 1600
WW [mm] 780 1150 1400 1420 1670 1715 1750
Weight [kg] 40 55 70 80 85 135 155
Maintenance accessories HPS 150 200 300 400 500 750 1000
Stainless steel-blind flange with conn. sleeve 1 œ"
[âŹ/item]Order number
200,-12539
200,-12539
200,-12539
200,-12539
200,-12539
200,-12539
200,-12539
Flange seal [âŹ/item]Order number
26,-38777
26,-38777
26,-38777
26,-38777
26,-38777
26,-38777
26,-38777
Stai
nles
s st
eel s
tora
ge ta
nks
64 I Stainless steel storage tanks · Product catalogue 2021
Stainless steel storage tank bis 5.000 Liter
May it be something more?Stainless steel storage tanks to 5.000 Litres
Stainless steel storage tank up 1250 Liter to 5000 Litres complete our range. Ask us.
www.huch.com I 65
Solar storage tank HSS Domestic water storage tank HBS Buffer storage tank HPS
Not in stock! Produced to customer requirements!
Storage type HSS / HBS / HPS 1250 1500 2000 3000 4000 5000
Contents [Litres] 1250 1500 2000 3000 4000 5000
Diameter without insulation [mm] 1000 1000 1100 1300 1400 1400
Diameter with insulation [mm] 1200 1200 1300 1500 1600 1600
Height with insulation HSS / HBS [mm] 1979 2230 2505 2826 3165 3665
Tilted height without insulation HSS / HBS [mm] 1966 2198 2465 2811 3153 3634
Height with insulation HPS [mm] 1914 2164 2505 2826 3165 3665
Tilted height without insulation HPS [mm] 1907 3137 2465 2811 3153 3634
Cold water / hot water (KW/WW) HSS / HBS [Inch] Rp 2 Rp 2 Rp 2 DN 65 DN 65 DN 65
Cold water / hot water (KW/WW) HPS [Inch] Rp 2 Rp 2 DN 65 DN 65 DN 65 DN 65
Circulation (Z) HSS / HBS [Inch] Rp Ÿ Rp Ÿ Rp Ÿ Rp 1 Rp 1 Rp 1
Circulation (Z) HPS [Inch] Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ Rp Ÿ
Sensor/controller connections [Inch] Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ
Thermometer connections [Inch] Rp œ Rp œ Rp œ Rp œ Rp œ Rp œ
Weight HSS (Solar) [kg] 245 265 330 540 670 790
Weight HBS (Domestic water) [kg] 225 250 310 515 600 700
Weight HPS (Buffer) [kg] 180 215 285 450 575 670
Technical data (excerpt)
Stai
nles
s st
eel s
tora
ge ta
nks
66 I other products · Product catalogue 2021
© panthermedia.net / Jan Mika
www.huch.com I 67
Quality features
Other Huch vesselsFor the most varied of applicationsPressurized-water boilers, compressed air tanks, filter boilers and expansion tanks for open-type heating systems round off our extensive product range.
Domestic water-suitedThe pressurized-water and filter boilers are hot-dip galvanized in compliance with domestic water considerations on the basis of DIN EN 1461
Qualified manufacturingDWK - manufactured as per European RL 2014/68/EU (pressure equipment) and AD 2000. DLB - manufactured as per European RL 2014/29/EU (non-complex pressure equipment, EN 268 1)
Corrosion protectionThe compressed air and expansion tanks are available in various corrosion-protection types - galvanized or with a rust protection primer.
1
2
3
Not found the right product up to now?The following products are available at your request:
Buffer storage tank from 200 to 25.000 Litres
Cold water buffer storage tank from 300 to 25.000 Litres
enamelled storage tanks to 5.000 Litres
Mobile mixed tank
Baking oven tank
Tanks for combined heat & power plants
Pressure tanks for braking systems
Tanks for compressors
Oil collecting vessels
Tanks for railway engineering
... and much more!
Our calculation aid for custom-made storage tanks and an extract from the dimensions chart is on hand from Page 80. Here you can get an idea of the dimensions. All attachment and mounting parts as well as the enquiry form can be found on the pages that follow.
othe
r pro
duct
s
68 I other products · Product catalogue 2021
Vertical pressurised water tank DWK
Product description
Explanation of the illustration (vertical)1 Hand hole or Manhole closures max. 45° with reference to the tank axis2 Hand hole closure only for tanks with a nominal capacity of 1000 litres3 Bottom according to DIN 280114 Connection for pressure controller5 Connections for water level gauge6 Connection for pump7 Connection for drainage and/or water mains or supply line8 Connection for water mains and/or supply line9 Connection for the exhaust system10 Connection for the ventilation system11 Auxiliary connection
» Manufactured according to RL 2014 / 68 / EU, AD 2000 leaflets and DIN 4810» Produced with pressure rates of 4, 5 or 10 bar
Price / order number
Technical data
Tank type DWK 150 300 500 750 1000 1500 2000 3000
Price
4 bar [âŹ/item] 647,- 805,- 1022,- 1605,- 1997,- 4359,- 5121,- 6712,-
6 bar [âŹ/item] 665,- 860,- 1086,- 1699,- 2082,- 4978,- 6139,- 7544,-
10 bar [âŹ/item] 1170,- 1512,- 1840,- 2360,- 3064,- 5954,- 6460,- 8525,-
Order number
4 bar 23536 23537 23538 23539 23540 23542 23543 23546
6 bar 00431 00121 00464 00467 00469 10382 50660 01434
10 bar 00116 00463 00466 00468 00470 10387 10344 01435
Tank type DWK 150 300 500 750 1000 1500 2000 3000
Content [Litres] 150 300 500 750 1000 1500 2000 3000
Diameter D1 [mm] 450 550 650 800 800 1000 1100 1150
Coating length +25 H1 [mm] 790 1100 1310 1250 1750 1560 1770 2500
Tank height H2 [mm] 1055 1405 1655 1655 2165 2060 2315 3085
Total height H3 [mm] 1275 1625 1875 1885 2385 2280 2535 3305
Connection D2 [Inch] Rp 2 Rp 2 Rp 2 Rp 2 Rp 2 Rp 3 Rp 3 Rp 3
Inpection opening
Piece 1 1 1 1 2 1 1 1
Hand hole 100 x 150 100 x 150 100 x 150 100 x 150 100 x 150 â â â
Manhole â â â â â 320 x 420 320 x 420 320 x 420
Weight at permissible compressive strenght
4 bar 40 62 100 143 178 350 465 514
6 bar 40 62 100 143 178 350 465 514
10 bar 50 89 138 185 230 383 490 649
www.huch.com I 69
Horizontal pressurised water tank DWK
Explanation of the illustration (vertical)1 Hand hole2 Bottom according to DIN 280113 Connection for pressure controller4 Connection for manometer5 Connections for water level gauge6 Connection for pump inlet pipe7 Connection for water mains and/or power supply
Note: The domestic water ordinance stipulates that water must not be corrosive. A measure for revealing this is the pH-value and the calcite dissolution capacity. The latter involves examining the extent to which lime from the water can be deposited in the pipes or whe-ther water can corrode metallic pipes and thus enable metals (e.g. copper, zinc) to get into the domestic water.As a consequence, de-scaling or neutralisation units for treating the domestic water may be needed (recommended amongst others pH > 7.5; calcite dissolution capacity < 5.0 mg/l) to stop, for instance, pitting as well as pitting and surface corrosion.
» Manufactured according to RL 2014 / 68 / EU, AD 2000 leaflets & DIN 4810» Produced with pressure rates of 4 and 6 bar» The design and arrangement of the connections are based on the requirements of renowned pump manufacturers and their drawings» The illustration shows the basic types of the wide range of products of horizontal DWKs» Specific drawings of each pump manufacturer on request» Specific drawings of the pump manufacturer (e.g. ORPU / OSNA / LOEWE) on demand
Product description
Price
Tank type DWK 60 80 100 100 150 200 250 300
Content [Litres] 60 80 100 100 150 200 250 300
D [mm] 350 350 350 400 450 500 550 550
L1 [mm] 765 960 1160 850 1070 1030 1145 1350
L2 [mm] 575 770 970 670 810 800 895 1070
Weight [kg] 28 33 37 37 44 54 62 68
Tank type DWK 60 80 100 100 150 200 250 300
Price Ă=350 Ă=400
4 bar [âŹ/item] 668,- 686,- 692,- 711,- 736,- 794,- 884,- 930,-
6 bar [âŹ/item] 684,- 704,- 719,- 732,- 754,- 863,- 951,- 1090,-
Technical data
Symbolic illustation!
Pump console
Order number
6 bar (Orpu/Mico) 00502 00506 00472 - 00482 - - -
6 bar (OSNA) 00503 - - 00475 00480 00488 00492 00497
6 bar (Loewe/Grundfoss) - - - 00427 00481 00489 00493 00496
Order number on request!
othe
r pro
duct
s
70 I other products · Product catalogue 2021
Vertical compressed air tank DLB
Product description
Price
Tank type DLB 40 60 90 150 250 350 500 750 1000Content [Litres] 40 60 90 150 250 350 500 750 1000Diameter D [mm] 300 300 350 400 500 550 600 750 800Height without feet L [mm] 674 924 990 1310 1400 1610 1780 1880 2160Feet height F [mm] 200 200 200 200 200 200 200 180 180Total height H [mm] 824 1074 1140 1460 1600 1810 1980 2060 2310Coating length M [mm] 500 750 800 1110 1160 1350 1500 1500 1750N [mm] 100 300 300 560 540 530 520 490 480O [mm] 450 700 750 1010 990 980 1310 1280 1270
X [mm] â â â 250 250 250 250 250 250Sleeves A1 RP [Inch] 1 1 1 1 1 1 1 1 1A2 RP [Inch] â â â 1 1 1 1 1 1A3 RP [Inch] ÂŒ ÂŒ ÂŒ Âœ Âœ Âœ Âœ Âœ ÂœA4 RP [Inch] Âœ Âœ Âœ 1 1 1 1 1 1A5 RP [Inch] Âœ Âœ Âœ Âœ Âœ Âœ Âœ 1 Âœ 1 ÂœHLV [Stk] â â â 1 1 1 1 1 2Weight 11 bar [kg] 29 35 50 60 90 130 145 220 300Weight 16 bar [kg] 34 42 60 75 110 140 165 270 330
Tank type DLB 40 60 90 150 250 350 500 750 1000Price 11 bar - prime coated [âŹ/item] 619,- 753,- 822,- 1165,- 1276,- 1566,- 1706,- 2584,- 2767,-11 bar - zinc-plated [âŹ/item] 762,- 904,- 959,- 1369,- 1622,- 1986,- 2246,- 3307,- 3474,-16 bar - prime coated [âŹ/item] 753,- 892,- 1126,- 1423,- 1505,- 1785,- 1986,- 2586,- 3908,-16 bar - zinc-plated [âŹ/item] 917,- 1034,- 1418,- 1748,- 1887,- 2167,- 2628,- 3369,- 4569,-Order number on request!
» The compressed air tanks up to 750 litres, 11 bar are manufactured according to Directive RL 2014/29/EU Modul C1 and EN 286 - 1, and from 750 litres, 16 bar according to Pressure Equipment Directive 2014/68/EU and the AD 2000 leaflets.» Permissible operating temperature: -10 - 50°C / from 750 litres 16 bar 0 - 50°C» Connections: Sleeves according to DIN 2986, threads according to DIN 2999» Inspection opening: HLV hand hole closure 100 x 150 mm» Corrosion protection: outside primed / inside uncoated; inside and outside hot-dip galvanised» Compressed air tank with a capacity of more than 1000 litres on request
Technical data
Not in stock! Produced to customer requirements!
www.huch.com I 71
Horizontal compressed air tank DLB
Product description
Price
» The compressed air tanks up to 750 litres, 11 bar are manufactured according to Directive 2014/29/EU Modul C1 and EN 286-1, and from 750 litres, 16 bar according to Pressure Equipment Directive 2014/68/EU and the AD 2000 leaflets.» Connections: Sleeves according to DIN 2986, threads according to DIN 2999
» Permissible operating temperature: -10 - 50°C» Inspection opening: HLV hand hole closure 100 x 150 mm» Corrosion protection: outside primed in grey / inside uncoated; inside and outside hot-dip galvanised» Compressed air tank with a capacity of more than 1000 litres on request
Technical data
Tank type DLB 40 60 90 150 250 350 500 750 1000Price 11 bar - prime coated [âŹ/item] 619,- 753,- 822,- 1287,- 1330,- 1566,- 1706,- 2307,- 2767,-11 bar - zinc-plated [âŹ/item] 762,- 904,- 959,- 1520,- 1672,- 1987,- 2246,- 2968,- 3368,-16 bar - prime coated [âŹ/item] 753,- 892,- 1022,- 1423,- 1505,- 1809,- 1986,- 2586,- 3908,-16 bar - zinc-plated [âŹ/item] 954,- 1034,- 1222,- 1748,- 1887,- 2321,- 2628,- 3307,- 4569,-Order number on request
Tank type DLB 40 60 90 150 250 350 500 750 1000Content [Litres] 40 60 90 150 250 350 500 750 1000Diameter D [mm] 300 300 350 400 500 550 600 750 800Total length L [mm] 755 924 990 1310 1400 1610 1780 1860 2160Feet height F [mm] 70 70 70 70 70 70 70 100 100Total height H [mm] 370 370 420 470 570 620 670 850 900Coating length M [mm] 585 750 800 1110 1160 1350 1500 1500 1750O [mm] â â 110 130 175 200 200 200 200P [mm] 70 140 150 250 245 340 415 415 350Q [mm] 400 500 500 670 670 670 670 670 800T [mm] 45 45 45 45 45 45 45 45 50Sleeves A1 RP [Inch] ÂŒ ÂŒ ÂŒ ÂŒ Âœ Âœ Âœ Âœ ÂœA2 RP [Inch] Âœ Âœ Âœ Âœ Âœ Âœ Âœ Âœ ÂœA3 RP [Inch] â â ÂŒ ÂŒ Âœ Âœ Âœ Âœ ÂœA4 RP [Inch] Âœ Âœ Âœ 1 1 1 1 1 1A5 RP [Inch] â â 3/8 3/8 3/8 3/8 3/8 3/8 3/8A6 RP [Inch] 1 1 1Âœ 1 1 1 1 1 1A7 RP [Inch] ÂŒ ÂŒ ÂŒ ÂŒ Âœ Âœ Âœ Âœ ÂœHLV [Stk] â â â 1 1 1 1 1 2Weight 11 bar [kg] 29 35 50 60 90 130 145 220 300Weight 16 bar [kg] 34 42 60 75 110 140 160 270 330
only at 1.000 litres only at 1.000 litres
Connection Rp 1 œ" at galvanised version (both sides)
fishplateat 60 litres the drill-hole is Ă11 mmup to 90 litres long hole 20 x Ă10 mm
Not in stock! Produced to customer requirements!
othe
r pro
duct
s
72 I other products · Product catalogue 2021
Expansion vessel AG
Product description
Technical data
» Expansion vessels according to DIN 4807 for open heating systems» can be used in horizontal and vertical positionThe following corrosion protection variants are available:» coated with corrosion protection primer on untreated surface» hot-dip galvanisedNot in stock! Produced to customer requirements!
* For zinc-plated expansion vessels a weight increase of 7% must be considered.Note: General tolerances are applicable to measures of length: DIN 7168-m, for sheet size tolerances see DIN 1541
Tank type AG 30 50 75 100 125 150 200 250 300 400 500 600 800 1000
Content [Litres] 30 50 75 100 125 150 200 250 300 400 500 600 800 1000
D1 [mm] 300 350 400 400 500 500 500 500 600 650 700 700 800 800
D2 [Inch] Rp 1 Rp 1 Rp 1Œ Rp 1Œ Rp 1Œ Rp 1Œ Rp 1œ Rp 1œ Rp 1œ Rp 2 Rp 2 Rp 2œ Rp 2œ Rp 2œ
L1 [mm] 500 580 670 870 700 850 1110 1350 1180 1310 1420 1660 1700 2125
S [mm] 2 2 2 2 2 3 3 3 3 3 4 4 5 5
Tank type AG 30 50 75 100 125 150 200 250 300 400 500 600 800 1000
Price
prime coated [âŹ/item] 208,- 233,- 297,- 345,- 407,- 440,- 529,- 593,- 760,- 901,- 1127,- 1303,- 1544,- 2253,-
zinc-plated [âŹ/item] 282,- 322,- 370,- 432,- 514,- 554,- 669,- 760,- 950,- 1117,- 1381,- 1589,- 1974,- 1654,-
Order number
prime coated 01439 01035 01024 01021 01826 00252 02277 17410 15215 01027 14658 14667 10719 13572
zinc-plated 01442 01096 01009 01095 01824 02243 02276 03969 14451 02245 12605 19802 05404 18758
Price / Order number
www.huch.com I 73
Filter boiler FK
Product description
Technical data
Not in stock! Produced to customer requirements!Operating media: WaterOperating temperature: 0-50°CSleeves: DIN 2986 - Rp thread DIN 2999Corrosion protection: inside and outside hot-dip galvanised conform to drinking water DIN EN 1461
Tank type FK 240 350 500 750 1000
Content [Litres] 240 350 500 750 1000
Diameter without insulation D [mm] 450 550 650 800 800
Total Height A [mm] 1800 1800 1800 1800 2385
Tank Height B [mm] 1600 1600 1600 1600 2165
Coating length C [mm] 1400 1360 1300 1250 1750
Add. label holder E [mm] 590 570 540 515 765
Type plate F [mm] 810 790 760 735 985
G [mm] 45 45 45 45 50
Height of bottom flange H [mm] 150 175 200 200 250
I [mm] 55 55 55 55 60
J [mm] 200 200 200 200 200
Height of top flange K [mm] 150 175 200 200 250
L [mm] 45 45 45 45 50
M [mm] 18 18 20 20 22
Weight 6 bar [kg] 101 129 180 242 322
Price on request! othe
r pro
duct
s
74 I Calculation support regarding custom-made storage tanks · Product catalogue 2021
Custom-made storage tanksCustomization down to the last detail
FeaturesBuffer storage tank and cold water buffer storage tank up to 25.000 litres capacity with max. 2.400 mm dia-meter and max. 6.000 mm height (3 / 6 bar)
Buffer storage tank and cold water buffer storage tank up to 6.000 litres capacity with max. 1.250 mm diame-ter and max. 6.000 mm height (10 bar)
Enamelled domestic water and buffer storage tanks up to 5.000 litres and a 1.500 mm diameter and max. 3.150 mm height (3 / 6 / 10 bar)
Operating pressure up to 16 bar
Operating temperature: Cold water storage tank: -10°C - 50°C Storage tank: 0°C - 95°C Heat exchanger: 0°C - 160°C (25 bar)
High-grade S235JR+N / P265 quality steel
Various heat and low-temperature insulations available (ErP)
Insulationen for funding program (e.g. BAFA) on demand
Stand/foot ring:
» Buffer storage tanks up to à 1.600 mm and a max. 5.000 litres » Enamelled storage tanks up to à 1.500 mm and a max. 5.000 litres
Feets:
» Buffer storage tanks above à 1.600 mm and upwards of 5000 litres » Enamelled storage tanks above à 1.500 mm and upwards of 5.000 litres » All cold water buffer storage tanks (on account of the air circulation)
Further services: Hot-dip galvanizing / AGI exterior coating / TĂV test (pressure equipment)
Custom-made storage tanks and vessels are an indispensable addition to our range of products. We would be more than happy to assemble the tank that you require based on your individual particulars and requirements. Just send an enquiry to us.
Flange nozzlesFor connecting the continuative tubing. Number and position of the flange nozzles can be selected at will.
Tube bendEnlarges optimum height utilization of the storage tank.
HandholeInspection openings for pressure equipment (small-size vessel).
ManholeInspection openings for pressure equipment (large-size vessel).
Inspection flange with blind flange and sealEnables a fin-tubed heat exchange or a flange electric heater to be retrofitted.
Blind flange with connection sleeve G 1 œ" and sealEnables a screw-plug electric heater to be retrofitted.
Connection sleeveFor the purpose of attaching measuring equipment such as thermometers, pressure gauges.
www.huch.com I 75
Stratified guide channelsEnables the flow within the vessel
to be specifically stratified.
Layer perforation plateMakes possible stratification
inside the vessel.
Nozzle tubesDirect the main flow through without
generating any turbulence in the vessel. Made of steel and stainless steel.
Hoisting eyeThey allow vessels to be
transferred and positioned using crane handling equipment.
Bare-tube heat exchangerUsing an external heat source (e.g. solar thermal system) to
heat the storage tank water.
Threaded nozzleFor attaching continuative
tubing with a threaded adapter.
Sensor clamping stripFor variable positioning of
the temperature sensor.
Cust
om-m
ade
tank
s
76 I Calculation support regarding custom-made storage tanks · Product catalogue 2021
Not in stock! Produced to customer requirements!
100 400 1000 1150 35 37100 450 800 950 34 36150 450 1200 1350 44 46200 500 1200 1350 51 54250 550 1250 1400 56 58300 550 1500 1650 65 68400 550 1650 1800 80 84500 600 2000 2150 93 98550 600 2220 2370 102 108600 650 2050 2200 104 129650 650 2200 2350 110 135700 650 2350 2500 117 144750 700 2250 2400 124 154800 750 2350 2500 136 168850 750 2150 2300 129 153750 790 1800 1950 119 147800 790 1870 2020 124 152835 790 1950 2100 127 155800 790 1850 2000 123 151
1000 790 2300 2450 147 1761100 790 2500 2650 158 189800 850 1650 1800 121 152
1000 850 2050 2200 154 1871100 850 2190 2340 157 1911200 850 2400 2550 170 2031000 900 1850 2000 142 2261150 900 2050 2200 154 2431300 900 2300 2450 170 2671000 950 1650 1800 140 2191250 950 2200 2350 166 2621500 950 2400 2550 179 2831250 1000 1850 2000 186 253
1500 1000 2150 2300 209 2841750 1000 2500 2650 235 3201600 1100 1950 2100 228 2931800 1100 2150 2300 246 3192000 1100 2350 2500 263 3412000 1150 2200 2350 256 3682500 1150 2700 2850 298 4323000 1150 3170 3320 334 4982000 1200 2050 2200 270 3782500 1200 2500 2650 313 4393000 1200 2950 3100 357 4892000 1250 1950 2100 272 3792500 1250 2350 2500 307 4283000 1250 2750 2900 347 4803000 1400 2250 2400 465 6454000 1400 2950 3100 525 7685000 1400 3600 3750 590 8556000 1400 4200 4350 660 9757000 1400 4900 5050 735 11203000 1500 2100 2250 496 7084000 1500 2600 2750 555 8005000 1500 3200 3350 625 9206000 1500 3700 3850 680 10157000 1500 4250 4400 750 11608000 1500 4800 4950 805 12454000 1600 2300 2450 610 8105000 1600 2800 2950 665 9106000 1600 3300 3450 765 10107000 1600 3800 3950 850 11108000 1600 4300 4450 930 12109000 1600 4700 4850 1010 1310
10000 1600 5300 5450 1100 1410
* Tilted height: max. height with footring, lower height with feets!
Hot water storage tank (3/6 bar) & Cold water storage tank (6 bar)» 100 mm Polyline© fleece insulation for hot water storage tanks» 25 mm "Elastomer" insulation for cold water storage tanks» Other insulating variants possible on request » Vessel on stand ring or bases » Optionally in 3 / 6 / 10 & 16 bar (conditional on capacity)
» Enamelling possible up to 5.000 litres and à 1.500 mm» External coating possible as per AGI Worksheet Q151 for cold storage tanks for an extra charge (up to 5000 litres)We would be happy to provide you with an individual supply offer for other pressure levels and sizes up to 25.000 litres. Do use our enquiry form for this.
Calculation support regarding custom-made storage tanks
Excerpt from our size chartBasic tank for buffer-, drinking water and cold water storage tanks (KWP)
Contents [Litres]
Ă [mm]
Height [mm]
Tilted height* [mm]
Weight [kg]
Weight [kg]
3 bar (95°C) 6 bar (95°C)
Contents [Litres]
Ă [mm]
Height [mm]
Tilted height* [mm]
Weight [kg]
Weight [kg]
3 bar (95°C) 6 bar (95°C)
Enquiry for custom-made storage tanks
www.huch.com I 77
Size
Flange nozzles (PN 6 / PN 16)DIN 2631â/âEN1092-1 Lenght: ~ 140 mm
DN 15
DN 20
DN 25
DN 32
DN 40
DN 50
DN 65
DN 80
DN 100
DN 125
DN 150
DN 200
DN 250
DN 300
Size
Tube bend with flange nozzles (PN 6 / PN 16)DIN 2633â/âEN1092-1
DN 15
DN 20
DN 25
DN 32
DN 40
DN 50
DN 65
DN 80
DN 100
DN 125
DN 150
DN 200
DN 250
DN 300
Size
Connection sleeve(for KWP / Buffer)DIN 2986
1/2 Inch
3/4 Inch
1 Inch
1 1/4 Inch
1 1/2 Inch
2 Inch
Size
Branch sleeves 1/2 Inch
3/4 Inch
1 Inch
1 1/4 Inch
1 1/2 Inch
2 Inch
Size
Hoisting eye (for transport)
Size individually per storage tank!
Size
Layer perforation plate(more sizes on request)
Ăž 550 mm
Ăž 600 mm
Ăž 650 mm
Ăž 750 mm
Ăž 800 mm
Ăž 1000 mm
Ăž 1100 mm
Ăž 1300 mm
Ăž 1400 mm
Ăž 1600 mm
Size
Stratification guiding channels
400 mm
500 mm
600 mm
720 mm
820 mm
920 mm
1020 mm
Size
Bare-tube heat exchangerincluding optional connectionsUp to 2000 litres, an internal heating coil is available; from 2500 litres we recommend using an external heat ex-changer for more efficiency
1,2 mÂČ
1,8 mÂČ
2,4 mÂČ
3,0 mÂČ
3,6 mÂČ
4,2 mÂČ
5,0 mÂČ
6,0 mÂČ
Size
Sensor clamping strips 500 mm
800 mm
Size
Stainless steel nozzle tubes up to 1000 mm (more sizes on request)
DN 100
DN 125
DN 150
DN 200
DN 250
DN 300
Size
Steel 1.0038 nozzle tubes up to 1000 mm (more sizes on request)
DN 65
DN 80
DN 100
DN 125
DN 150
DN 200
DN 250
DN 300
Size
Inspection flange with blind flange incl. seal
DN 200 (DIN 4805)
DN 200
DN 300 PN 6 (EN1092)
DN 400 PN6 (EN1092)
DN 500 PN6 (EN1092)
Size
Blind flange with connectionsleeve G1 œ" incl. seal
DN 200 (DIN 4805)
Size
Manhole 420 x 320 mm
Size
Hand hole 100 x 150 mm
Size
Impact plate(Deflector plate)
60 x 60 x 3 mm
More accessories and components on request!
Accessories & components for custom-made storage tanks
Cust
om-m
ade
tank
s
78 I Calculation support regarding custom-made storage tanks · Product catalogue 2021
Copy, complete and fax the form. Drawing of Connections
The General Terms and Conditions for Sale and Delivery of Huch GmbH BehÀlterbau und Werwaltungsgesellschaft as well as the agreements acknowledged with order acceptance shall apply to all transactions. Subject to any kind of changes and errors. In order to maintain warranty, only original parts may be used as replacement parts such as seals etc.
Send the completed enquiry form by fax (0049 - 33920 - 672 77) or by e-mail ([email protected]) to our quotation pro-cessing department and you will promptly receive an offer for your desired storage unit.
Description Amount
Insulation:
Date: Signature:
Buffer storage tank Cold water storage tank
Drinking water storage tank Others
Content Litres Compressive strenght bar
Connections Item Operating temperature °C
Diameter Ă mm max. Height mm
Various feet design: Foot ring or Feets
rear360°/0°
180°
90°right
270°left
Company:
Adress:
Contact person:
Telephon:
E-mail:
Project:
Storage information
Information about the customer Please draw the positions of the connecting pieces schematically.
Enquiry for custom-made storage tanks
www.huch.com I 79
Examples Buffer storage tank / Cold water buffer storage tank
Cust
om-m
ade
tank
s
80 I Accessories · Product catalogue 2021
www.huch.com I 81
Additional plus: by regularly servicing and maintaining the heating system energy savings of up to 10 % can be made.
Did you know that...
Original Huch accessoriesEverything from a single source
The general warranty on our products is only maintained given that original Huch accessories are used for the prescribed maintenance and upkeep of the heating system.
High-grade magnesium anodesCompletes the corrosion protection of enamelled domestic water storage tanks.
Additionally fitted flangeFor bolt-on fitting of an electric heater or a fin tube heat exchanger as well as an inspection opening.
This is where you also find the right seal needed for servicing the storage tank.
Electric heatersFor additionally heating the heating and domestic water at peak times. This is where you find the right electric heater for the most varied of storage tank types.
1 1
2
3
3 2
Acce
ssor
ies
82 I Accessories · Product catalogue 2021
Accessories
Additionally integrated flange» for the storage unit types PSX-F, PSX-F2, PSB-F2, SPSX-F, SPSX-F2» specified standard position, see pages with details on storage types» closed with seal and blind flange» flange for PSB-F2 is enamelled» flange for PSX and SPSX is primed» inspection flange for KWP» for the installation of a finned tube heat exchangers» for the installation of an electric heating
Storage type Nominal width [mm] Ă external [mm] Bolt circle [mm] Price [âŹ/item]
PSB-F2 200 280 245 281,-
PSX-F, -F2 200 280 245 217,-
SPSX-F, -F2 200 280 245 217,-
KWP 200 280 245 217,-
Flange system for additional self-assembly» suited for any steel storage units without enamelling» including blind flange, seal and screwsOrder no. Nominal width [mm] Ă external [mm] Bolt circle [mm] Price [âŹ/item]
11379 200 280 245 158,-
Blind flange
Order no. Nominal width [mm] Ă external [mm] Bolt circle [mm] Hole pattern Design Storage type Price [âŹ/item]
03683 110 180 150 8 x Ă14 uncoated 1 21,-
00046 200 280 245 12 x Ă16 uncoated 2 57,-
05148 200 280 245 12 x Ă16 one side enamelled 3 88,-
Blind flanges with connection sleeve G 1Âœâ
Order no. Nominal width [mm] Ă external [mm] Bolt circle [mm] Hole pattern Design Storage type Price [âŹ/item]
06202 110 180 150 8 x Ă14 enamelled 1 x G 1Âœâ 1 45,-
06201 200 280 245 12 x Ă16 uncoated 1 x G 1Âœâ 2 49,-
10358 200 280 245 12 x Ă16 uncoated 2 x G 1Âœâ 2 60,-
05619 200 280 245 12 x Ă16 enamelled 1 x G 1Âœâ 3 94,-
10452 200 280 245 12 x Ă16 enamelled 2 x G 1Âœâ 3 121,-
12539 110 180 150 8 x Ă14 Stainless steel 1.4571 1 x G 1Âœâ 4 200,-
46213 110 180 150 8 x Ă14 enamelled 1 x G 1Âœâ 5 45,-
06202 06201 10358 05619 10452 12539 46213
03683 00046 05148
www.huch.com I 83
Reducing flange» Reducing flange for series type R electric heating for assembly in flange 280 x 210 x LK 245
Order no. Ă external [mm] Bolt circle [mm] Hole pattern Design Price [âŹ/item]
12536 280 245 12 x Ă16 enamelled 114,-
12537 280 245 12 x Ă16 uncoated 103,-
Accessories
Flange seals
Design flange seal Suitable for flange + storage tank
Order no. Design Hole pattern
Nominal width [mm]
Ă external [mm]
Bolt circle [mm]
Storage type Price [âŹ/item]
03684 3 x 140 (Scheibe) ohne 110 180 LK Ă 150, 8 x Ă14 1 without E-Hzg. 13,-
01429 4 x 200 x 280 12 x Ă15 200 280 LK Ă 245, 12 x Ă16 2 / 3 15,-
38777 3 x 100 x 180 8 x Ă14 110 180 LK Ă 150, 8 x Ă14 1 with E-HZG. 4 / 5 / 6 / 8
26,-
11561 3 x 410 x 495 18 x Ă13 410 495 LK Ă 462, 18 x Ă13 7 28,-
04034 3 x 142 x 210 10 x Ă14 140 210 LK Ă 180, 10 x Ă14 9 16,-
Blind flange / seal / flange E-HZG / blind flange with sleeve / seal / flange
Storage type1 SSH 301-501, ESS-PU 200-500, BS 122-501, EBS-PU 120-500,
HLS-Plus 150-501, SSH-Plus 351-801, SSK 300-5006 SKSV
2 PSX-F, SPSX-F 7 SKSE, SKSV, SKSW, SKSP
3 SSH 751-2000, BS 751-2000, PSB 200-2000 8 WWS-TS
4 HSS 200-1000, HBS 150-1000, HPS 150-1000 9 Internal tank for combined storage tank SKSE
5 HSO, SKSE
12536 12537
03684 01429 38777 11561 04034
Acce
ssor
ies
84 I Accessories · Product catalogue 2021
Accessories
Overview anodes installed in standard storage tanksAnode type Anode Impressed current anode
Order no. Anode 05712 05713 05714 03679 04041 04042 04390 05328 10892 04509 24463 26054Price [âŹ/item]: 29,- 34,- 35,- 37,- 42,- 62,- 70,- 25,- 29,- 293,- 468,- 468,-Design Anode
for Storage type
StandardĂ 33 x
350 mm G 5/4"
StandardĂ 33 x
487 mm G 5/4"
StandardĂ 33 x
580 mm G 5/4"
StandardĂ 33 x
687 mm G 5/4"
StandardĂ 33 x
887 mm G 5/4"
StandardĂ 33 x
1087 mm G 5/4"
StandardĂ 33 x
1487 mm G 5/4"
insulatedĂ 33 x
400 mm M8x30
insulatedĂ 33 x
500 mm M8x30
insulated G 1 Œ"
1x 800 mm
insulated G 1 Œ"
2x 800 mm
insulated G 1 Œ"
1x 400mm1x 800 mm
ESS-PU 200 â ESS-PU 300 â ESS-PU 400 â ESS-PU 500 â SSH 301 â SSH 401 â SSH 501 â SSH 751 â SSH 1001 â SSH 1500 â SSH 2000 â SSH-Plus 351 â SSH-Plus 501 â SSH-Plus 801 â EBS-PU 120 â EBS-PU 150 â EBS-PU 200 â EBS-PU 300 â EBS-PU 400 â EBS-PU 500 â BS 122 â BS 152 â BS 202 â BS 301 â BS 401 â BS 501 â BS 751 â BS 1001 â BS 1500 â BS 2000 â HLS-Plus 150 â HLS-Plus 200 â HLS-Plus 301 â HLS-Plus 401 â HLS-Plus 501 â HLS-Plus 801 â PSB 200 â PSB 300 â PSB 400 â PSB 500 â PSB 750 â PSB 1000 â PSB 1500 â PSB 2000 â HSO 120 â HSO 150 â WWS-TS 120 â WWS-TS 150 â WWS-TS 200 â SKSE 200 â
Note: Allow only authorised specialists to perform electrical connections according to the German VDE regulations and the provisions of theutility companies. This must also be observed for malfunctions and repairs. The combination with CrNi (NIRO) boilers is problematic and thus not recommendable.
www.huch.com I 85
Protection anodes for enamelled tanks - Anoden exchange (maintenance) and retrofitting» magnesium protection anodes suited for all enamelled tanks with G 1ÂŒâ anode sleeves» insulated anodes are required when used together with anode testers
insulated magnesium protection anode Optional insulated chain link anodeOrder no. Length [mm] Price [âŹ/item] Order no. Number chain links Length [mm] Price [âŹ/item]
10176 350 33,- â â â â
04616 700 40,- â â â â
05187 900 46,- 28717 6 + 1 1218 92,-
05188 1100 51,- 28716 8 + 1 1548 100,-
05295 Anode tester for control board assembly
21,- â â â â
Standard magnesium protection anode Optional chain link anodeOrder no. Length [mm] Price [âŹ/item] Order no. Number chain links Length [mm] Price [âŹ/item]
05712 350 29,- â â â â
05713 487 34,- â â â â
05714 580 35,- 15379 5 796 66,-
03679 687 37,- 05013 6 961 98,-
04041 887 42,- 14972 7 1126 86,-
04042 1087 62,- 17459 9 1456 103,-
Accessories
Impessed current anode» suited for all enamelled tanks with G 1ÂŒâ anode sleeves» maintenance-free permanent anode as an alternative to magnesium protection anodes» 230 V socket required for wall power supply» including operating manual and circuit diagram
Order no. Installation depth [mm] for tank capacity [litres] Price [âŹ/item]
11259 100 bis 300 167,-
10601 400 400 â 500 244,-
04509 800 ab 750 - 1250 293,-
24463 2 x 800 (as Set) 1500 - 2000 468,-
26054 1x 400 / 1x 800 (as Set) SSH-Plus / HLS-Plus 800 468,-
CorroScoutŸ 500 anode test device» measures the drive voltage of isolated magnesium protection anodes as well as Correx impressed current anodes against container/tank» measures protective currents (direct currents) as well as mains voltage (230V AC/115V AC)» measures the potential balancing resistance, the functionality of reverse polarity protection diodes as well as the internal resistance of control sensors up to max. 20 kΩ» Scope of delivery: measuring instrument, cable kit, test tips, crocodile clips, operating manual
Order no.: 17780 Price [âŹ/item]: 147,-
Order no. Details Storage type Price [âŹ/item]
28246 Conversion kit for M8 anodes WWS-SRO, WWS-TS, Combined storage tank 56,-
Standard magnesium anode insulated magnesium anode M8 anode chain link anode insulated chain link anode Anode tester
Impessed current anode Conversion kit M8
Acce
ssor
ies
86 I Accessories · Product catalogue 2021
Ăbersicht - die passende E-Heizungen fĂŒr Ihren Speicher (technische Daten und Preise auf den Folgeseiten)
Betriebsart Zusatzbetrieb Dauerbetrieb
Spannung 230 V 400 V 400/230 V 3 ~ 400 V 400 V
230
V
400
V
Leitung (kW) 1,5
1,8
2,0
2,5
3,0
3,0
4,5
6,0
9,0
3,0
4,5
6,0
3,0
5,0
6,0
6,0
7,5
10,0
12,0
15,0
3,0
4,5
6,0
9,0
12,0
4,0
4,0
Anschluss (Muffe oder Flansch)
G 1 Âœâ(E-HZG-Muffe)
DN110 (Flansch)
G 1 Âœâ(E-HZG-Muffe)
Type
EHK1
-i 1
5
EHK1
-i 1
8
EHK1
-i 2
0
EHK1
-i 2
5
EHK1
-i 3
0
EHK3
-i 3
0
EHK3
-i 4
5
EHK3
-i 6
0
EHK3
-i 9
0
EHK3
-i P
V
EHK3
-i P
V
EHK3
-i P
V
RDU
1 /
3,0
RDU
1 /
5,0
RDU
1 /
6,0
KDW
6KW
-0 /
6,0
RDW
1 /
7,5
RDW
1 /
10,0
RSW
1 /
12,0
RSW
1 /
15,0
EHK
3 30
EHK3
45
EHK3
60
EHK3
90
EHK3
120
EHK-
KS 4
0
EHK-
KS 4
0
Artikel-Nr.
fĂŒr Speichertyp 0990
1
0990
2
0990
3
0990
4
0990
5
0990
6
0990
7
0990
8
0990
9
3278
0
3278
1
3278
2
1546
6
1626
3
1472
3
2179
5
1487
7
1258
2
1253
5
1359
8
0991
0
0991
1
0991
2
0991
3
0991
4
0991
5
0991
6
Sola
rspe
iche
r
ESS-PU 200 â â â â â â â â â â â ESS-PU 300 â â â â â â â â â â ESS-PU 400 â â â â â â â â â â â â â â â â â ESS-PU 500 â â â â â â â â â â â â â â â â â â SSH 301 D600 â â â â â â â â â â â â â â â â â SSH 301 D550 â â â â â â â â â â â â â â â SSH 401 â â â â â â â â â â â â â â â â â SSH 501 â â â â â â â â â â â â â â â â â â SSH 751 â â â â â â â â â â â â â â â â â â â SSH 1001 â â â â â â â â â â â â â â â â â â â â SSH 1500 â â â â â â â â â â â â SSH 2000 â â â â â â â â â â â â SSH-Plus 351 â â â â â â â â â â â â â â â â â SSH-Plus 501 â â â â â â â â â â â â â â â â â â SSH-Plus 801 â â â â â â â â â â â â â â â â â â â â
Brau
chw
asse
rspe
iche
r
EBS-PU 120 â â â â â â â â â â EBS-PU 150 â â â â â â â â â â EBS-PU 200 â â â â â â â â â â EBS-PU 300 â â â â â â â â â â EBS-PU 400 â â â â â â â â â â â â â â â â â EBS-PU 500 â â â â â â â â â â â â â â â â â â BS 122 â â â â â â â â â â BS 152 â â â â â â â â â â BS 202 â â â â â â â â â â BS 301 â â â â â â â â â â â â â â â â BS 401 â â â â â â â â â â â â â â â â â BS 501 â â â â â â â â â â â â â â â â â â BS 751 â â â â â â â â â â â â â â â â â â â BS 1001 â â â â â â â â â â â â â â â â â â â â BS 1500 â â â â â â â â â â â â BS 2000 â â â â â â â â â â â â HLS-Plus 150* â â â â â â â â HLS-Plus 200* â â â â â â â â HLS-Plus 301* â â â â â â â â â â â â â â â â HLS-Plus 401* â â â â â â â â â â â â â â â â â â HLS-Plus 501* â â â â â â â â â â â â â â â â â â HLS-Plus 801* â â â â â â â â â â â â â â â â â â â PSB 200* â â â â â â â â â â â â â â â â PSB 300* â â â â â â â â â â â â â â â â PSB 400* â â â â â â â â â â â â â â â â â â PSB 500* D600 â â â â â â â â â â â â â â â â â â PSB 500* D650 â â â â â â â â â â â â â â â â â â â PSB 750* â â â â â â â â â â â â â â â â â â â PSB 1000* â â â â â â â â â â â â â â â â â â â â PSB 1500* â â â â â â â â â â â â â â â â â â â â PSB 2000* â â â â â â â â â â â â â â â â â â â â
Accessories
www.huch.com I 87
Artikel-Nr.
fĂŒr Speichertyp 0990
1
0990
2
0990
3
0990
4
0990
5
0990
6
0990
7
0990
8
0990
9
3278
0
3278
1
3278
2
1546
6
1626
3
1472
3
2179
5
1487
7
1258
2
1253
5
1359
8
0991
0
0991
1
0991
2
0991
3
0991
4
0991
5
0991
6
Puff
ersp
eich
er
SPSX 200 â â â â â â â â â â â SPSX 300 â â â â â â â â â â â SPSX 400 â â â â â â â â â â â â â SPSX 500 â â â â â â â â â â â â â SPSX 600 â â â â â â â â â â â â â SPSX 800 â â â â â â â â â â â â â â SPSX 850 â â â â â â â â â â â â â â SPSX 1000 D790 â â â â â â â â â â â â â â SPSX 1000 D850 â â â â â â â â â â â â â â SPSX 1100 â â â â â â â â â â â â â â SPSX 1500 â â â â â â â â â â â â â â SPSX 1650 â â â â â â â â â â â â â â SPSX 2000 â â â â â â â â â â â â â â SPSX 2200 â â â â â â â â â â â â â â SPSX 3000 â â â â â â â â â â â â â â SPSX-G/ 2G 500 â â â â â â â â â â â â â SPSX-G/ 2G 600 â â â â â â â â â â â â â â SPSX-G/ 2G 800 â â â â â â â â â â â â â â SPSX-G/ 2G 850 â â â â â â â â â â â â â â SPSX-G/ 2G 1000 D790 â â â â â â â â â â â â â â SPSX-G/ 2G 1000 D850 â â â â â â â â â â â â â â SPSX-G/ 2G 1100 â â â â â â â â â â â â â â SPSX-G/ 2G 1500 â â â â â â â â â â â â â â SPSX-G/ 2G 2000 â â â â â â â â â â â â â â PSFW /-G 500 â â â â â â â â â â â â â PSFW /-G 800 â â â â â â â â â â â â â PSFW /-G 1000 â â â â â â â â â â â â â â
Kom
bisp
eich
er
SKSW 601SKSW 801 â â â â â â â â â â â SKSW 1001 â â â â â â â â â â â SKSW 1251 â â â â â â â â â â â â â SKSW 1501 â â â â â â â â â â â â â WKS-WP 600 â â â â â â â â â â â â â WKS-WP 800 â â â â â â â â â â â â â WKS-WP 1000 â â â â â â â â â â â â â WKS-WP 1250 â â â â â â â â â â â â â WKS-WP 1500 â â â â â â â â â â â â â WKS 600 â â â â â â â â â â â â â WKS 800 â â â â â â â â â â â â â WKS 1000 â â â â â â â â â â â â â WKS 1250 â â â â â â â â â â â â â WKS 1500 â â â â â â â â â â â â â
Edel
stah
lspe
iche
r
HSS 200 â â â HSS 300 â â â HSS 400 â â â HSS 500 â â â HSS 750 â â â â HSS 1000 â â â â â HBS 150 â â HBS 200 â â â HBS 300 â â â HBS 400 â â â HBS 500 â â â HBS 750 â â â â HBS 1000 â â â â â HPS 150* â â â HPS 200* â â â HPS 300* â â â HPS 400* â â â HPS 500* â â â HPS 750* â â â â HPS 1000* â â â â â
*Einbau E-HZG nur ĂŒber Revisionsflansch, keine E-HZG-Muffe vorhanden
Acce
ssor
ies
88 I Accessories · Product catalogue 2021
Accessories
Series type R built-in electric heatings for enamelled storage units (for solar and domestic water storage tank)The series type R built-in heatings are suited for a max. operating pressure of 10 bar; depending on their power, they include a corresponding number of high-qua-lity tubular heaters which are mounted on a flange plate by means of a separately applied protective current resistor. The heating power is controlled by means of an externally adjustable thermostat. Moreover, each built-in heating is equipped with a safety temperature limiter which switches off the heating at all poles if the temperature controller fails. The complete wiring, control devices and connecting clamps are covered by black plastic caps. The required type of built-in heating can be selected from the provided table on the basis of the desired power and ins-tallation position, the available installation length and the required heating groups. For article 13598 (RSW 15 kW), a contactor control is required. The combination with CrNi (NIRO) boilers is problematic and thus not recommendable.
Order no. Type / Power [kW] Voltage [V] Depth [mm] Nominal width Flange-Ă [mm] Price [âŹ/item]
15466 RDU 1 / 3,0 3~400 450 DN 110 180 / LK 150 8 x Ă14 445,-
16263 RDU 1 / 5,0 3~400 450 DN 110 180 / LK 150 8 x Ă14 445,-
14723 RDU 1 / 6,0 3~400 450 DN 110 180 / LK 150 8 x Ă14 445,-
21795 KDW 6 KW - 0 / 6,0 3~400 375 DN 110 180 / LK 150 8 x Ă14 445,-
14877 RDW 1 / 7,5 3~400 450 DN 110 180 / LK 150 8 x Ă14 491,-
12582 RDW 1 / 10,0 3~400 450 DN 110 180 / LK 150 8 x Ă14 491,-
12535 RSW 1 / 12,0 3~400 530 DN 110 180 / LK 150 8 x Ă14 567,-
13598 RSW 1 / 15,0 3~400 630 DN 110 180 / LK 150 8 x Ă14 640,-
Note: Allow only authorised specialists to perform electrical connections according to the German VDE regulations and the provisions of theutility companies. This must also be observed for malfunctions and repairs. The combination with CrNi (NIRO) boilers is problematic and thus not recommendable.
Built-in electric heating for enamelled and uncoated storage units (for solar, domestic water, buffer, combined storage tank)» insulated electric heating especially for the use in enamelled solar storage units and storage units for industrial water as auxiliary or emergency heating» easy installation due to 1Âœâ screw head with male thread» unheated length 100 mm» not suited for continuous operation» 3 variants available 1) single-pole built-in electric heating with temperature preselection by means of a thermostat with a setting range of 3 - 68°C, preset at 55°C, and a safety temperature limiter at 87°C, antifreeze mode 2) U-shaped, three-pole built-in electric heating with temperature preselection by means of a thermostat with a setting range of 25 - 70°C and and a safety temperature limiter at 98°C, antifreeze mode 3) for PV systems with three heating elements which can be heated separately» for the installation in a blind flange, the corresponding blind flange with sleeve and seal must be ordered separately
Order no. Typ Power [W] Voltage [V] Installation length [mm] Price [âŹ/item]
09901 Screw-in electric heating EHK1-i 15 1500 230 400 171,-
09902 Screw-in electric heating EHK1-i 18 1800 230 400 171,-
09903 Screw-in electric heating EHK1-i 20 2000 230 400 171,-
09904 Screw-in electric heating EHK1-i 25 2500 230 400 171,-
09905 Screw-in electric heating EHK1-i 30 3000 230 400 171,-
09906 Screw-in electric heating EHK3-i 30 3000 400 390 241,-
09907 Screw-in electric heating EHK3-i 45 4500 400 470 245,-
09908 Screw-in electric heating EHK3-i 60 6000 400 550 280,-
09909 Screw-in electric heating EHK3-i 90 9000 400 780 333,-
32780 Screw-in electric heating EHK3-i PV 3000 400 / 230 390 243,-
32781 Screw-in electric heating EHK3-i PV 4500 400 / 230 470 248,-
32782 Screw-in electric heating EHK3-i PV 6000 400 / 230 550 283,-
EHK 1
EHK 3-i
EHK 3-iPV
www.huch.com I 89
Built-in electric heating for stainless steel tanks» U-shaped, three-pole built-in electric heating» easy installation due to 1Âœâ screw head with male thread» round protective cap made of plastic / black» temperature preselection by means of a thermostat with a setting range of 25 - 70°C, a safety temperature limiter at 98°C and an antifreeze mode at 8°C» unheated length 100 mm» including operating manual and circuit diagram» for the installation in a blind flange, the corresponding blind flange with sleeve and seal must be ordered separatelyOrder no. Typ Power [W] Voltage [V] Installation length [mm] Price [âŹ/item]
09910 Screw-in electric heating EHK3 30 3000 400 290 275,-
09911 Screw-in electric heating EHK3 45 4500 400 350 306,-
09912 Screw-in electric heating EHK3 60 6000 400 450 312,-
09913 Screw-in electric heating EHK3 90 9000 400 650 321,-
09914 Screw-in electric heating EHK3 120 12000 400 750 333,-
Built-in electric heating (extra short) (for buffer and combined storage tank)» built-in three-pole electric heating, coiled» easy installation due to 1Âœâ screw head with male thread and made of stainless steel» temperature preselection by means of a thermostat with a setting range of 30 - 85°C, a safety temperature limiter at 110°C and an antifreeze mode at 6°C» unheated length 100 mm
Order no. Type Power [W] Voltage [V] Installation length [mm] Price [âŹ/item]
09915 Screw-in electric heating EHK-KS 40 4000 230 275 318,-
09916 Screw-in electric heating EHK-KS 40 4000 400 275 328,-
Accessories
Cu finned tube heat exchanger» Finned tube heat exchanger for heating hot water or buffer storage units» Huch storage units with a flange diameter of 280 mm can be easily retrofitted with these heat exchangers. The required blind flange plates and seals are included in the scope of supply.» all joints are brazed with silver solder» the outside of the finned tube heat exchangers are galvanically tin-plated» the electrically insulated connection fittings (required for drinking water storage units with anode protection) are supplied together with the heat exchanger» different sizes available (single and double coil)» max. operating pressure 10 bar, max. operating temperature 150 °C
Typ BW 10-1 BW 13-1 BW 18-1 BW 23-1 BW 26-2 BW 31-2 BW 36-2 BW 45-2Heating surface [mÂČ] 1,0 1,2 1,8 2,3 2,5 3 3,6 4,5Continuous output [kW] 17 21 33 39 40 48 58 72Connection [Inch] R Âœ R Ÿ R Ÿ R Ÿ R 1 R 1 R 1 R 1Installation sizesD [mm] 140 147 170 170 175 175 175 175L [mm] 350 410 440 540 510 540 650 790a [mm] 40 50 60 60 48 48 48 48g / h [mm] â â â â 45 / 110 45 / 110 45 / 110 45 / 110Complete installation kit (for uncoated storage units)Order no. 17664 17666 17668 17670 17672 17674 17676 17678Price [âŹ/item] 517,- 574,- 695,- 804,- 906,- 1085,- 1292,- 1449,-Complete installation kit (for enamelled storage units)Order no. 17665 17667 17669 17671 17673 17675 17677 17679Price [âŹ/item] 626,- 642,- 710,- 799,- 896,- 1101,- 1336,- 1492,-
a
a
70±3
gh
15±1,5
G
G
L
L
D
D
Acce
ssor
ies
90 I Accessories · Product catalogue 2021
Accessories
OthersOrder no. Description Price [âŹ/item]
06209 3 levelling feet for storage unit with foot ring up to max. 500 litres 36,-
06210 4 levelling feet for storage unit with foot ring up to max. 1000 litres 44,-
14499 3 levelling feet for EBS/ESS-PU 19,-
14498 Temperature display for EBS/ESS-PU (thermometer incl. sleeve 55 mm M8) 18,-
06597 Temperature display for storage unit with 100 mm polyline fleece insulation(thermometer incl. sleeve 100 mm M8)
19,-
17446 Industrial bimetallic thermometer 15,-
38319 Cover strip for hook closure strip polyline fleece insulation (800 x 90 x 1.5 mm) 15,-
38323 Assembly aid for hook closure strip polyline fleece insulation (100 x 90 x 1.5 mm) 12,-
29318 Expansion sleeve (set of 2 pcs.) 25,-
22933 flexible storage tank connection including a corrugated pipe made of stainless steel, length 200 - 300 mm, 1 œ'' IG 37,-
46771 storage tank connection including a corrugated pipe made of stainless steel, length 300 mm, 1 œ'' AG 62,-
20851 Universal assembly kit (complete kit incl. mounting material)
Assembly kit for the storage unit and wall assembly of many common freshwater replacement stations, optionally also suited for solar stations (max. distance of fixation points W x H 560 x 540 mm); quick and easy assembly; variably adjustable by means of profile rails
62,-
58031 Insulating caps for 100 mm sleeves Rp 1œ" 13,-
Internal tank for combined storage tanksOrder no. Description Price [âŹ/item]
05079 Internal tank for combined storage tank 200 Liter 10 bar enamelled 846,-
11500 Internal tank for combined storage tank 200 Liter 10 bar stainless steel 1479,-
26502 Internal tank for combined storage tank ~27 Liter 5 mÂČ stainless steel corrugated pipes 1â 1234,-
26505 Internal tank for combined storage tank ~43 Liter 8 mÂČ stainless steel corrugated pipes 1â 1367,-
11561 Seal for internal tank 28,-
Fig. Universal assembly kit
Circulation lance» circulation lance for circulation connection to the hot water discharge of combined storage units with corrugated pipes made of stainless steel (SKSW)» circulation only in the upper part (approx. 1m) of the corrugated pipe» consisting of: âą T-piece R 1â (IG) âą 1 soldering joint 1 "male thread with Âœ" male thread and soldered corrugated hose DN 8, 600mm long
Order no.: 51050 Price [âŹ/item]: 108,-
www.huch.com I 91
Accessories
Boiler accessoriesOrder no. Description Price [âŹ/item]Pressure switch00906 MDR 5/5 max. Switch-off pressure 5 bar 141,-00913 MDR 5/8 max. Switch-off pressure 8 bar 189,-01407 MDR 5/11 max. Switch-off pressure 11 bar 207,-12510 MDR 4S/6 max. Switch-off pressure 6 bar 153,-Water level display up to 6 bar00911 1 pair of water level display fittings Âœâ 95,-00909 Water level pipe Ă 12 mm 680 mm to 750 Litres 23,-00910 Water level pipe Ă 12 mm 980 mm to 1000 Litres 29,-41167 Seal for water level pipe 7,-41168 Collar ring 11,-Water level display up to 10 bar01417 1 pair of water level display fittings Âœâ rugged design 164,-01418 MS protective tubes (brass) 950 mm 166,-01419 Borosilicate glass tube Ă 12 mm 980 mm 48,-Further accessories01408 1â spring non-return valve 36,-01409 1ÂŒâ spring non-return valve 48,-01410 1Âœâ spring non-return valve 58,-01395 Ventilation valve ÂŒâ Fig. 406 57,-00912 Drain cock ÂŒâ made of brass 60,-01791 Handhole closure, complete 100 x 150 mm, 6 bar, zinc-plated 36,-53753 Handhole closure, complete (2019) Cover, bracket, Seal, 114 x 164 mm, 6 bar, zinc-plated 37,-15116 Handhole closure Orpu, complete 100 x 150 mm, 6 bar, zinc-plated 49,-01903 Manhole closure, complete 320 x 420 mm, ring height 90 mm, 10 bar 438,-02407 Rubber seal HLV 100 / 130 x 150 / 180 x 6 (oval) 16,-01494 Rubber seal HLV (Orpu) 93 / 143 x 138 / 188 x 4 13,-01005 Seal (manhole closure) 320 / 370 x 420 / 470 x 10 106,-01393 Manometer (please indicate pressure stage on your order) 6 bar 18,-01406 Manometer ÂŒâ 0 - 10 bar 12,-
Pressure switch Manometer Drain cock Ventilation valve Water leveldisplay fitting
Handholeclosure
Manholeclosure
Acce
ssor
ies
92 I Product catalogue 2021
Our quality features
Quality featuresGood reasons for Huch quality products
1 2 3
4 5 6
High-grade bare-tube heat exchangerThanks to a special heat exchanger design and arrangement a high extraction grade of up to 96% is attained.
Flexible sensor positioningSensor clamping strips allow the temperature sensor to be positioned at will. As a result, the Huch storage tanks are suitable for many application fields. (barring storage tanks with PU rigid foam; here firmly positi-oned sensor/controller connections).
Innovative storage tank insulationPolylineÂź fleece insulation - High-grade fleece insulation incl. 100 mm cap and 50 mm base insulation; this reduces the heat loss by 10-15 %.
PU rigid foam insulation - Vessels are firmly foamed with high-grade polyurethane foam No chimney effect arises. The insulation is 50 mm thick and has excellent insulating properties.
Connection stubsOur connection stubs are a standard 50 mm in length. The fleece insulation thus insulates any non-used connections. This cuts radiation losses and an improved energy efficiency is achieved by the storage tank.All enamelled storage tank types have flat-sealing male threads. This stops the enamel peeling off at the installation stage.
Manifold connection scopeOur combined and buffer storage tanks have a host of connections. This makes possible an optimum system attachment for the most varied of applications.
Optimum temperature stratificationStratification guiding channels and baffle plates ensure that temperature swirls in the storage tank are reduced.
Use of the entire storage tank capacityAn optimum hot water connection at the top of the storage tank means that the storage tank capacity is fully utilised.
1
2
3
4
5
6
www.huch.com I 93
Cert
ifica
tes
/ Qua
lifica
tions
/ W
arra
nty
Certificates / Qualifications / Warranty
We are certificated and qualified on the basis of:
DNV GL tanks according to GL rules
Brandenburger Umweltsiegel
TĂV certificate:
» Quality management system as per Iso 9001:2015
» Manufacturer and welding undertaking in keeping with AD 2000 HP 0 / DIN EN ISO 3834
» RL 2014/68/EU Pressure equipment (CE 0035)
» RL 2014/29/EU Non-complex pressure equipment, EN 286 Parts 1 + 3
Our warranty pledge Huch GmbH BehÀlterbau und Verwaltungsgesellschaft grants the following on:
Standard storage tank range: A 5-year warranty*
Stainless steel storage tank and Stainless steel currugarted tube: A 2-year warranty*
Galvanised tanks: A 2-year warranty*
Polyline© fleece insulation: A 2-year warranty*
Domestic water-, solar-, buffer- and combined storage tank: A 10-year warranty (optional)**
* A warranty claim can only be made on condition that all stipulations of the sales and delivery terms of Huch GmbH BehÀlterbau und Verwaltungsgesellschaft are met. Substantiation is on hand that commissioning and installation was carried out by a specialist tradesman or an authorized specialist company in kee-ping with the installation and maintenance information attached to the storage tank or vessel. It is assumed that the components were fitted correctly. It can be proved across the entire service life of the vessel and anode that they were regularly serviced. (completely filled-in pass card, proof on hand from invoice copies of the maintenance work). ** possible for an extra charge / special arrangement
94 I Product catalogue 2021
Note the following when undertaking installation:
General installation instructions
These general installation instructions do not replace the assembly and installation instructions attached to the storage tank. They contain additional instructions pertaining to the appliance!
Requirements placed on where installation takes place» Only install storage tank where there is no risk of frost» Firm, level base that can absorb loads» Short piping lengths to the user
Transfer to where the installation takes place» Clear the path to the installation site of any obstacles and items that could cause you to trip» Note the dimensions of the storage tank
Gap to the walls and solid fuel boilers» Keep to the minimum spacing as specified in the installation and assembly instruction attached to the storage tank» In keeping with the fire system ordinance, a minimum spacing of 1.000 mm is to be kept to the boiler (sparks could fly)
Commissioning» An authorized specialist firm is to undertake assembly, installation and commissioning» Seal tightness is to be checked at the commissioning stage » Before filling the system, check and, if necessary, re-tighten the tightening torques of the flange connection. This is also to be done after each start-up and after the initial heat-up» Tightening torque of the flanges: 20 - 30 Nm» Seals represent wear parts and are only to be used once» Flat-sealing R-threaded joints must not be used for any other purposes (R-thread with thread sealant, e.g. hemp or sealing tape, are not permitted)» Cold water access line to be fitted with an appropriate water filter» Handle heating water in line with VDI 2035n» The specified operating temperatures and pressure must not be exceeded
The installation of heating and domestic water storage tanks is subject to DIN, DVGW and VDI regulations and recommendations. They include the instruction on avoiding mixed installations and corrosion damage.
Maintenance instructionsParticular attention is to be given to the following rules and recommendations:» Internal inspection / cleaning is recommended 1x a year» Sealstobereplacedduringmaintenanceormodificationwork,butafter2yearsattheverylatest» Only use genuine parts when undertaking maintenance
www.huch.com I 95
Gene
ral i
nsta
llatio
n in
stru
ctio
ns
Domestic water must not react corrosively on enamel or stainless steel
Domestic water is to be within the TWVO determining limits (electrical conductivity â„ 200 ÎŒS/cm)
Domestic water PH figure: <8 / ideally 6.5 - 7
Water hardness: min. 7° dH
Stainless steel: A chloride content above 120 mg/l at temperatures of ℠60°C is considered to the critical
galvanized tanks and boilers: up to a max. 50°C
Installation - Domestic water storage tankWater is a precious item that keeps us alive
Water properties:
Domestic water storage tanks at the installation stage are subject to specific, tighter specifications. This is to rule out contamination of whatever kind. Acting as a form of corrosion protection enamelling has a vital role to pay given that water is a corrosive medium. Our domestic water storage tanks are designed in an enamel-compliant manner. This means there are no sharp edges inside the vessel where the enamel does not adhere properly, the enamel layer is uneven or major imperfections could develop. Even so, it is not possible to produce a 100% fault-free enamel surface. That is why magnesium or impressed-current anodes are additionally used to protect the minimum flaws.
» Installation in acc. with DIN and DVGW specifications (including DIN EN 806, DIN 1988, DIN 4753, DIN EN 1717)» Pay attention to the regulations of the local water supplier
» Avoid any pressure blows in the domestic water mains grid e.g. from an expansion tank or delay-closing valves etc.
Note the following when installing a domestic water storage tank:
Our enamelled domestic water storage tanks comply with the strict domestic water ordinance as per §17 of the German Environmental Office and are deemed hygienically unproblematic. The same holds good for all those deployed components in contact with domestic water during operations. The smooth enamel surface reduces limescale and coating formation down to a minimum.
Domestic water conformity - pro-duction in acc. with UBA guidelinesWhat counts is the quality of the materials used
96 I Product catalogue 2021
Buffer storage tanks are selected and designed in line with the following parameters:
Dimensioning of buffer storage tanks
Buffer storage tanks are used in the most varied of heating systems. They store hot water from when heated until its extraction when required and, in this way, bridge operating interruptions of the heat generators. Only correct dimensioning saves you from unnecessary energy consumption and costs.
As-needed design calculation acc. to heat generator:
Note: If it is a matter of the size of the buffer storage tank (tank capacity), then preference should preferably be given to the larger appropriate model. It must be appreciated here that the capacity of the buffer storage tanks increases four-squared to the diameter. This means that a larger buffer storage tank will always be higher than thicker. Please refer on this to our size chart as from Page 80.
Hot water storage tank dimensioningEstablishing what is needed for efficient operation of the heating system
» Type of heat generation, e.g. CHP, solid fuels, solar
» Receiving system types, e.g. under-floor heating, domestic water, radiators
» Loading and unloading capacities
» Individual heat demand
» Properties of the heat transferring fluid
» Hydraulic components and aspects (pressure ratios)
» Characteristics of the heat-transferring components
» Utilization degree
» Effective heat flow volume in kWh
» Additional heating system
VPS = 15 * QK * TB * (1 - 0,3 * QH / QKmin )
VPS = Capacity of the buffer storage tank in l
QK = Boiler rated output in kW
TB = min. boiler output in kW
QH = Nominal burn-off period in h
QKmin = Heating load of the building in kW
VPS = Capacity of the buffer storage tank in l
PWP = Heat output of the heat pump in kW
t = Bridging time given an interruption to operations
c = Specific water heat capacity
âT = Temperature difference Supply flow / Return flow in K
VPS = Capacity of the buffer storage tank in l
AWF = Living space to be heated in m3
VSP = Specific storage tank flow per m2 of collector surface in l/m2
aWF = Specific living space per m2 of collector surface in l/m2
Solid fuels - in keeping with DIN EN 303-5:
Heating pumps:
Solar installations:
VPS = AWF * VSP
aWF
VPS = PWP * t
(c * âT)
www.huch.com I 97
Dim
ensi
onin
g of
sto
rage
tank
s
Domestic water storage tanks are designed in line with the following parameters:
Dimensioning of domestic water storage tanks
The size of the domestic water storage tank should be optimally dimensioned and designed to cater for needs to ensure that the heating system is run in an energy and cost-efficient manner. The number of people in the household and their hot water consumption determine the hot water requirements. The 6023 VDI directive proceeds on the assumption of a daily per head consumption of 30-50 litres of domestic hot water. This is in addition to a minimum 100 litres capacity which planning should also consider.
» Number of those in the household
» Number of dwelling units (detached house or apartment block)
» Type of heat generation
» Boiler output
» Loading and unloading capacities
» Individual hot water demand
» Hydraulic components and aspects (pressure ratios)
Hot water demand - centrally supplied apartmentsDetermining the requirement figure N to establish the size of the hot water storage heater
1 2 3 4 5 6 7 8 9 10
Apar
tmen
t gro
ups
num
ber o
f roo
ms
num
ber o
f ap
artm
ents
num
ber o
f oc
cupa
nts
per f
lat
tapp
ing
poin
t nu
mb
brie
f des
crip
tion
(see
bel
ow)
tapp
ing
poin
t re
quire
men
t in
Wh
tapp
ing
poin
t num
ber
x ta
ppin
g po
int
requ
irem
ent i
n W
h
Wh
r n p n*p z wV z*wV n*p*ÎŁwV
1 4 1 3,5 3,5 1 NB1 5.820 5.820 20.370
As-needed design calculation in keeping with form DIN 4708-2 (example here of a detached house with bath-equipped bathroom):
Note: This is an extract from DIN 4708-2. The extensive design calculation of domestic water storage tanks is subject to additional calculations. They can be taken from the DIN.
ÎŁ(n*p*ÎŁwV) = 20.370 Wh N = 1
Procedure - Enter particulars in the following columns of the form:1] Consecutive number of the same apartments in acc. with number of rooms and extent of the sanitary equipment2] Number of rooms according to the structural drawings3] Number of apartments and/or residential units4] No. of occupants per flat acc. the owner5] Outcome of the multiplication Column 3 with Column 46] Number of tapping points to be considered (e.g. bath, washstand, sink)7] Brief description of the tapping points entered in Column 68] Tapping point requirement based on particulars from9] Outcome of the multiplication Column 6 with Column 810] Outcome of the multiplication Column 5 with Column 9Enter the outcome in the equation of the supply pressure and calculate the N requirement figure.
Calculate the storage tank on the basis of the N requirement figure and the NL capacity figure, NL â„ N applies here!
tapping point briefdescription WV in Wh VE in L
Bath NB1 5820 140
Bath NB2 6510 160
Small bathroom-sized bath KB 4890 120
Bath for a large-area bathroom GB 8720 200
Shower set with mixer tap BRS 1630 40
Standard shower set BRN 3660 90
Luxury shower set RRL 7320 180
Washstand WT 700 17
Bidet BD 810 20
Wash basin HAT 350 9
Sink SP 1160 30
ÎŁ(n*p*ÎŁwV) 20.370 Wh
3,5 * 5.820 20.370 WhN = = = 1
98 I Product catalogue 2021
Important notes regarding this price list
Prices
All prices are non-binding end customer prices and do not include value-added tax. With the publication of this price list, any other previ-ous price lists shall cease to be valid.
Sales
Our products are exclusively sold by wholesalers.
Amendment
We continuously develop our products and therefore reserve the right to make changes to the products, the delivery program and the prices at any time and without prior notice. We accept no liability for any printing errors or mistakes. Any claims, especially claims for damages, are excluded!All illustrations are symbolic representations and do not necessarily have to correspond to the actual design.
Datasheets, standards, guidelines and warranty
Technical data sheets and tender texts can be found on our website www.huch.com. In addition to the information in the product catalog, the standards, guidelines and leaflets that are not expressly mentioned as well as the relevant regulations must also be observed. To maintain the warranty, only original Huch parts should be used for replacement parts such as seals, anodes, etc.
General Terms and Conditions
Our General Terms and Conditions for Sale and Delivery as well as the agreements acknowledged with order acceptance shall apply to all transactions.
Copyright
Huch GmbH BehÀlterbau und Verwaltungsgesellschaft, MÀrkisch Linden, Germany. Anything from this issue may only be copied or published in any other way with prior written or oral approval and if the source is indicated. The data mentioned only apply to the application of Huch products. Huch does not assume any liability for incorrect use, application or the false interpretation of technical data. Huch GmbH Be-hÀlterbau und Verwaltungsgesellschaft further points out the applicable General Terms and Conditions for Sale and Delivery (AGB). Image copyrights: Product illustrations - www.huch.com, images - panthermedia.net; pixabay.de; istockphoto.com/de.
Declaration of Conformity
This is to declare the conformity for the hot water tanks (product group 01-05) included in this price list according to the:
DELEGATED RESOLUTION (EC) No. 812/2013 OF THE COMMISSION of 18 February 2013 as amendment of Directive 2010/30/EC of the European Parliament and the Council with regard to the energy efficiency labelling of water heaters, hot water tanks and composite systems consisting of water heaters and solar equipment
and
RESOLUTION (EC) No. 814/2013 OF THE COMMISSION of 2 August 2013 implementing Directive 2009/125/EC of the European Parlia-ment and the Council with regard to the specification of requirements for the environmentally-friendly design of water heaters and hot water tanks. All devices meet the requirements of the regulations as of the applicable effective dates and are provided with the CE mark.
Abbreviations
A/A1/A2 Connection
AG male thread
ANO1/ANO2 optional anodes
E-HZG electric heating
F/F1/F2 Sensor/controller connections
G separated
GWT Bare-tube heat exchanger
HLV hand hole closure
HS rigid foam insulation
IG female thread
KW cold water
max. P HZG maximum pressure of heating
max. P TW maximum pressure of drinking water
max. P WT-HZG max. pressure of heat exchanger heating
max. T maximum temperature
NL number key performance indicator of the storage tank
R male thread, conically sealing
RFL inspection flange
RL (a) external return flow of heat exchanger
RL (i) internal return flow of heat exchanger
RL/RL 1/RL2 heat exchanger (return flow)
Rp female thread, conically sealing
TW corrugated pipe corrugated pipe for drinking water
Vl fleece insulation
VL (a) external inlet flow of heat exchanger
VL (i) internal inlet flow of heat exchanger
VL/VL 1/VL 2 heat exchanger (inlet flow)
WT heat exchanger
WW hot water
Z Circulation
www.huch.com I 99
§ 1 Scope All agreements, offers and deliveries are carried out exclusively on the basis of the business conditions given below.
Thus, they also apply to future business relations, even if they are not separately agreed upon. Differing, conflicting or supplementary General Terms and Conditions of Business shall not, even upon knowledge
thereof, become part of the contract, unless their application is expressly agreed to in writing Terms and conditions of the contracting party that we have not expressly acknowledged are invalid.
§ 2 Delivery contract1 Our offers are without obligation. Technical changes as well as changes in form, colour and/or weight are reserved
within reasonable limits.2 Dimensions, weights, illustrations and drawings, including all information and illustrations in brochures and catalogues,
shall only be binding if this is expressly agreed in writing. Information and illustrations contained in brochures and catalogues are, in accordance with usual trade practice, regarded as approximations unless they have been expressly described by us as binding. In the event that any of the parties to the contract provides the other party with designs or technical documents with regard to the goods to be delivered or their production, such material shall remain the property of the providing party.
3 Partial deliveries are permissible within our specified delivery times, provided that this does not result in disadvanta-ges for the use of the goods.
4 Once the customer places an order for a product they declare their intention to buy the ordered goods as binding. We are entitled to accept the contractual offer made in the order within two weeks after receipt by our company. Accep-tance can be declared either in writing or by the delivery of goods to the customer.
5 If the customer has ordered the merchandise via electronic channels, we shall save the contract text and supply it to the customer on request along with these General Terms and Conditions by e-mail.
6 In the event of industrial disputes or unusual and unforeseeable events, such as actions of a government or any other state authority, traffic interruptions and/or force majeure, we shall be entitled to carry out the delivery only after the problem concerned has been rectified or be exempt from the obligation to deliver, if delivery is rendered impossible. The supplier shall notify the buyer without delay of the beginning and the end of any such event.
7 The quality of the goods is based solely on the agreed technical delivery regulations. If we are to deliver according to drawings, specifications, patterns etc. provided by the customer, then the customer shall accept the risk of the product's suitability for its intended use. The instant of passing the risks is decisive for the contractual condition of the goods. In this respect, we shall be liable only for the proper processing. If not expressly agreed upon, we shall not be held respon-sible for determining the material quality nor for any defects caused by corrosion.
§ 3 Delivery periods1 Unless otherwise agreed, we deliver "ex works". For meeting the delivery date or the delivery deadline, the notification by
us that the consignment is ready for shipping or collection is decisive.2 Delivery times are binding only if we have expressly designated them as such and confirmed them in written form.3 The period for delivery begins with the dispatch of the confirmation of order, but not before the provision [...] of any do-
cuments, approvals and clearances to be furnished if necessary by the customer and before the receipt of any agreed down payment. If, at a later stage, errors are detected in the order documents or drawings or it is found that necessary technical information is missing, then the delivery time begins anew upon rectification of the problems concerned.
4 It is considered that the delivery deadline has been complied with, if the delivery object has left the supplier's factory before the expiry of this deadline or if the supplier has notified the readiness for shipping on his part.
5. Part deliveries are permissible within the delivery periods specified by us, as long as there are no disadvantages for the use thereof.
6. The conclusion of the contract is subject to the correct and timely self-delivery by our suppliers. This only applies to cases in which we are not culpable for the non-delivery, in particular if a congruent coverage transaction is concluded with our supplier.7. If the delivery is not made at the agreed delivery date for reasons for which the customer is responsible, the purchaser
shall default in acceptance without a separate deadline being required by us. Each new delivery date must be confirmed by us in writing.
§ 4 Payment1 Unless otherwise agreed, all prices shall be ex works, i.e. plus a flat rate for shipping and plus the applicable VAT. Any
discount for cash must be agreed separately. We consider ourselves bound by the prices quoted by us and the terms of payment for the period indicated in the quotation. After the expiration of this period, we shall be entitled to make a reasonable price adjustment.
2. If the delivery can not be made within the deadline stated in the confirmation of order, we are entitled to demand negot-iations on an appropriate price adjustment. If an agreement cannot be reached within 6 weeks after our call for nego-tiations, we shall be entitled to cancel the contract and charge already rendered services and expenses on the basis of the contract price. The invoice amount shall be due within the agreed payment targets. If the customer defaults in payment, they shall pay interest on the monetary debt at a rate of 8 per cent points above the basic rate of interest of the EZB during the default in payment. We reserve the right to prove and assert higher damage caused by said default.
3 The customer may only exercise any rights of retention if their counterclaim is based on the same contractual relati-onship. The client is only entitled to set off counterclaims subject to final judgement or if accepted by us.
4 Non-compliance with the agreed payment conditions, and circumstances that become known to us after the conclusi-on of the contract and lead us to fear that the ordering party will be unable to pay in time, entitle us to request a security payment for all the claims from the delivery contract, regardless of the due date, and to suspend work until the security has been paid.
5 In the case of delayed payment we may suspend fulfilment of our obligations up to receipt of the payments after written notification of the purchaser.
6 Bills of exchange and cheques will only be accepted where this has been agreed, and only on account of performance and on condition that they may be discounted. Discount charges will be calculated from the due date for payment of the invoice amount. A guarantee that the bill and cheque will be presented on time and for the bill protest is precluded.
7. Price changes are permissible if more than four months have elapsed between the conclusion of the contract and the agreed delivery date (also for partial deliveries and partial installments). If, thereafter until completion of the delivery, the wages or material costs increase, we shall be entitled to increase the price appropriately in correspondence with the cost increases. The customer is only entitled to cancel if the price increase does not or not considerably exceed the consumer price index between the time of ordering and delivery.§ 5 Shipping and Transfer of Risk1 Goods reported as ready for dispatch shall be taken over by the partner without delay. Otherwise we shall be entitled
at our discretion to despatch or store them at the expense and risk of the partner.2. In the absence of any special agreement, we will select the means of transport and the transport route.3 With transfer to the railway, the forwarding or shipping company or with the start of the storage, at the latest however with
the departure from the plant or warehouse, the risk shall pass to the partner even if we have taken over the delivery.4 Insurance cover for transit damage is provided only on request and at the cost of the customer.§ 6 Default in delivery1 If we are able to anticipate that it will not be possible for the goods to be delivered within the delivery period, we will
immediately inform the partner of the reasons for this, and also if possible indicate the probable delivery date.2 In the event of delivery being delayed by one of the circumstances as set forth in § 2, or as a result of any action or
omission on the part of the partner, an extension of the delivery period will be granted appropriate to the circumstances.3 The partner is only entitled to withdraw from the contract if we are responsible for the delivery date not being met and
the partner has allowed us a reasonable period of grace without result.§ 7 Retention of title1 We reserve the title in the goods until full payment of any accounts receivable from a current business relationship,
irrespective of the legal foundation on which it is based. In case of running account, retention of title is deemed as security for our balance claims. This is even applicable when payments are made by the customer on especially desi-gnated claims.
2 The customer shall be obligated to treat the goods delivered with due care. Where maintenance and inspection work is necessary, the customer must carry this out regularly and at their own cost.
3 The processing or alteration of the reserved goods shall always be made for us as the manufacturer without our incur-ring any obligation from this. When processing or reorganisation of the reserved goods with other goods not delivered by us, the co-ownership of the new object is entitled to us according to the ratio of the reserved goods' value to the value of the other product which has been processed and reorganized at the time of processing or reorganization. In case our ownership of the reserved goods expires due to connection or confusion, the customer already now assigns their (co)-ownership of the new object or of the commingled merchandise to the amount of the invoiced value of the reserved goods to us and keeps them safe free of charge for us. The new object (called "new object" in the following), created by processing, reorganization, connection or confusion, or the (co)-ownership of the new object being the entitled or assigned to us according to subsection 2 of this section, respectively, serves to secure our claim in the same way as the reserved goods according to subsection 1 themselves. Unless nothing divergent arises from the following provisions regarding these subsections, this securing of claims is to be applied accordingly to the new object.
4 The customer may further sell the reserved goods only within the framework of the correct business transactions, subject to the usual business conditions and only as long as they do not default their payment obligations towards us. The customer is obliged on their part to further sell the reserved goods subject to reservation of title only and to ensure that the claims arising from such disposal activities may be transferred to us.
5. The customer's claim arising from the resale of the reserved goods is already assigned to us. These claims serve as a security to the same extent as the goods under reservation of ownership. If the customer sells the retained goods together with other goods that were delivered by other parties, then the assignment of the account receivable extends only to the pro-rata amount of invoice that represents the retained goods resold. The assignment of claims as regards the sale of the goods as stipulated in subsection 2 or in the legal provisions regulating the connection and confusion of the object of which we are co-proprietor shall be applied in the amount of our partial ownership.6 If the customer includes accounts receivables from retained goods resold in a mercantile current account relationship
that The preceding sub-paragraph is applied in so doing.7 The customer is entitled to retract the claim arising from the further sale of the reserved goods that had been assigned
to us. They are not entitled, however, to assign the claim arising from the further sale, not even in the context of a genuine factoring contract.
8 In this case the customer is obliged to immediately inform their buyers of the assignment of the claim as well as to hand over to us any documents, certificates and information necessary to justify and implement the claim.
9 If the realizable value of the securities at our disposal exceeds our secured claims by more than 15 %, we are prepared, upon request by the customer, to release securities, chosen by us, to this extent.
10 The customer is obliged to notify us immediately of any levy of execution or any other legal or actual hazard for the retained goods or for the other collateral that exists for our benefit.
11 The customer pledges to sufficiently insure the reserved goods against fire and theft. The customer hereby assigns to us in advance its claims from insurance contracts.
12 If the customer breaches the contract, particularly in the event of payment default or infringement of one of the obli-gations of this section, we have the right to cancel the contract and require the return of the goods. For this case, the customer already now agrees to our removing or having the reserved goods removed which were with the customer or - in the case of us being the sole owners - the new object as per subsection 2 of this section, respectively. For the purpose of undertaking these measures as well as for the purpose generally inspecting the retained goods or the new object, the purchaser shall grant us, or persons authorized by us, access to their premises at any time.
§ 8 Warranty1 We are not liable for material defects which result from unsuitable or inappropriate use, incorrect assembly commissi-
oning by the customer or third parties, usual wear, incorrect or careless treatment, as well as for the consequences of inappropriate changes and modifications or repairs, made without our consent by the purchaser or third parties. The same applies for defects that only negligibly reduce the value or serviceability of the goods.
2 We must be given the chance to ascertain the reported defect. The corresponding goods are to be sent back to us immediately on demand. Should the customer fail to observe this obligation, or make modifications to such goods without our approval, they will lose any rights they may have on the grounds of product deficiency.
3 Initial warranty for defective merchandise is initially provided in the form of remedial repair or replacement according to our choice.4 If the subsequent performance fails, the customer may generally at its discretion demand a lowering of the payment
(reduction) or termination of the contract (withdrawal). In the event of a minor infringement of the contract, particularly for marginal defects, the customer is not entitled to cancel the contract.
5 In the case of obvious defects, the customer is obliged to immediately notify us in written form, at the latest within two weeks as of the receipt of the goods. Otherwise, assertion of the warranty claim shall be excluded. The punctual dispatch is sufficient for compliance with the warranty conditions. The customer shall be fully subject to the onus of proof for any reasons for claims, in particular for the defects as such, for the time of detecting the defect and for any notification of the defect being made in due course. In the case of acceptance having been agreed with the customer, the goods shall be considered approved upon acceptance. Otherwise, the assertion of the warranty claim is excluded and the goods shall be deemed approved, unless the defect is one that could not be detected during the careful ins-pection at the acceptance.
6 In case the customer chooses cancellation of the contract after the subsequent performance due to a defect failed, they shall not be able to claim additionally compensation for this defect. If the customer should choose to claim compensation for failure of subsequential fulfilment, the delivery item remains with the customer, provided that this is acceptable to them. The compensation is limited to the difference between the purchase price and the value of the defective good. The above shall not apply should we be guilty of malicious contract infringement. For contractors, the warranty term is 1 year from the delivery of goods. This does not apply if the customer has not informed us promptly of a defect. (Subsection 3 of this provision).
7 Generally only the product description of the manufacturer shall be deemed to be the agreed characteristics of the goods. Public statements, claims or advertisements by the manufacturer (of the product or individual components thereof) do not constitute contractually guaranteed characteristics of the goods. If the customer receives deficient assembly instructions, we shall be merely obligated to supply error-free assembly instructions and this also only if the error in the assembly instructions stands in the way of proper assembly. If, due to reasons we are not responsible for, the products manufactured by us cannot be delivered within the agreed time, those parts that have already been manufactured will be parked in unroofed and unmonitored storage areas at the orderer's expense and risk. In this case, the warranty period shall commence with the storage of the goods. As remuneration for storing the manufactured goods, we charge 1 % of the overall order sum for every month of storage commenced. The storage costs become payable on conclusion of the respective month of storage.
8 Claims against us in case of ordinary and minor negligence are limited to the total contract value.§ 9 Other claims, liability1 Unless specified otherwise below, other claims and claims of a wider scope against us on the part of the partner are
excluded This particularly applies to claims for compensation arising from infringement of duty from contractual obligations and from tortuous acts. Therefore, we will not compensate lost profits or other damage to the assets of the partner.
2 The above mentioned limitations of liability shall not apply for malice aforethought and gross negligence of our legal representatives or senior employees or for culpable breaches of essential contractual obligations. In the event of culpable breach of substantial contractual obligations, we shall - except in cases of deliberate acts or gross negligence on the part of our lawful representatives or executives - only be liable in respect of the damage which is typical of the contract and reasonably foreseeable.
3 To the extent that our liability is excluded or limited, this applies equally to the personal liability of our employees, workers, personnel, legal representatives and vicarious agents.
§ 10 Confidentiality1 Each of the contracting parties undertakes to use all documents (including samples, patterns and data) and knowledge
which they receive in the course of the business relationship for the jointly pursued purpose and to maintain their secrecy towards third parties with the same care as exercised with regard to their own equivalent property if these are designated as confidential or the other party has an obvious interest in maintaining their secrecy. This obligation commences with the first receipt of documents or knowledge and terminates 36 months after the end of the business relationship. We claim copyright protection for our quotation and contract documents, drawings, drafts and const-ruction details including all variants. They must not be copied or made accessible to third parties without our prior consent. Any use by the ordering party or any other third party requires our prior written consent and will be charged accordingly.
2 This obligation shall not apply to documents and knowledge which are generally known or which were already known on receipt without the partner being committed to confidentiality, or which were subsequently transferred by a third party entitled to pass them on or which were developed by the receiving contractual partner without the use of con-fidential documents or knowledge of the other contractual partner. In case a contract is not awarded, any documents provided by us must be returned to us without request within 6 working days at the latest.
§ 11 Final provision1 The laws of the Federal Republic of Germany shall apply. The provisions of the UN Sales Convention shall not apply.2 For all conflicts resulting from this contract, if the customer is a qualified merchant, a corporate body under public
law or a public law entity with special public funds, claims are to be filed at the court which is responsible for our head office. We are also entitled to file a suit at the customer's head office location. This applies even if the customer does not have a general place of jurisdiction in Germany or their place of residence or everyday domicile are not known at the time of institution of legal proceedings.
3 The place of performance is 16818 Werder.4 lf individual provisions of the contract with the customer including these standard conditions and terms of business
should be or become partly or wholly legally invalid, the validity of the remaining provisions will not be affected by this. The regulation which is totally or partially ineffective will be replaced by a regulation which will approximate the economical success of the ineffective regulation as closely as possible.
5 Any transfers of rights and obligations of the customer arising from the contract concluded with us require our written consent in order to be legally valid.
General terms and conditions
Gene
ral t
erm
s an
d co
nditi
ons
Huch GmbH BehÀlterbauund VerwaltungsgesellschaftTemnitz-Park-Chaussee 2216818 MÀrkisch Linden (Germany)
Telephone: +49 (0)33 920 - 672 0Telefax: +49 (0)33 920 - 672 72 / -73E-mail: [email protected]
Your contact persons
You can contact our staff by telephone from Monday to Thursday from 8.00 am to 5.00 pm and on Friday from 8.00 am to 3.00 pm!
Mareen MichaelisTelephone: +49 (0)33920 - 672 51E-mail: [email protected]
Ramona RĂŒtzTelephone: +49 (0)33920 - 672 50E-mail: [email protected]
Sven SzemkusTelephone: +49 (0)33920 - 672 66E-mail: [email protected]
Christine HerrmannTelephone: +49 (0)33920 - 672 56E-mail: [email protected]
Andreas RischerTelephone: +49 (0)33920 - 672 26E-mail: [email protected]
Sylvia Regina MaĂlowTelephone: +49 (0)33920 - 672 53E-mail: [email protected]
Marcel WeckwerthTelephone +49 (0)33920 - 672 35E-mail: [email protected]
Sales representation
Technical support
Sales North
Head of sales
Sales South Export sales
Custom-made tanks offer departmen
[5] Andreas SteinmĂŒllerAm Wolfsberg 898693 IlmenauTelephone: +49 (0)3677 - 89 49 49Telefax: +49 (0)3677 - 89 49 59Mobile: +49 (0)171 - 61 06 088E-mail: [email protected]
[6] IVT Otto Throm GmbHDahlienweg 1174589 SatteldorfTelephone: +49 (0)7951 - 47 34 20Telefax: +49 (0)7951 - 47 34 211E-mail: [email protected]
[10] Michael SteinmĂŒllerUnterpörlitzer Str. 32c98693 IlmenauTelephone: +49 (0)3677 - 66 72 983Telefax: +49 (0)3212 - 13 95 321Mobile: +49 (0)170 - 48 19 203E-mail: [email protected]
[1+2+11+12] via HUCH GmbHTemnitz-Park-Chaussee 2216818 MĂ€rkisch LindenTelephone: +49 (0)33 920 - 672 0Telefax: +49 (0)33 920 - 672 72 / -73E-mail: [email protected]
[3] Frank WernickeAm Rottersberg 537339 Leinefelde-WorbisTelephone: +49 (0)36074 - 30 288Telefax: +49 (0)36074 - 63 868Mobile: +49 (0)171 - 83 13 266E-mail: [email protected]
[4] IMG PlĂŒschke GmbHHöltenweg 9748155 MĂŒnsterTelephone: +49 (0)251 - 60 222Telefax: +49 (0)251 - 60 221E-mail: [email protected]
[7] Bolte Industrievertretung GmbHDr. SteinbeiĂer StraĂe 1283026 RosenheimTelephone: +49 (0)8031 - 46 774Telefax: +49 (0)8031 - 42 506E-mail: [email protected]
[8] UTZ Energie & Umwelttechnik GmbHHochfeldstraĂe 1393095 HagelstadtTelephone: +49 (0)9453 - 99 300Telefax: +49 (0)9453 - 99 30 20E-mail: [email protected]
[9] Handelsvertretung Roland BayrIndustriestraĂe 1786438 KissingTelephone: +49 (0)8233 - 57 73Telefax: +49 (0)8233 - 26 272E-mail: [email protected]
On Heizungslabel.de you will find all energy labels and product data sheets from our quality stores.
MEMBER OF
Find us atFacebook!
9
10
12