product catalogue 2016 - zagzoog.com · • note : specifications are based on the following...
TRANSCRIPT
PRODUCTCATALOGUE
2016
SPLIT / WINDOW
AIR CONDITIONERS LINEUP
2
NEW
NEW
NEW
NEW
NEW
NEW
INDOOR UNIT LINEUP
18,000
24,000
25,000
30,000
36,000
40,000
50,000
60,000
Capacity(BTU/h)
ASSA18FMTAASSA18UMTA
ASSA24FMTAASSA24UMTA
ASSA30FMTAASSA30UMTA
ASSA36FETAASSA36UETA
Duct Type
ARSA18FMTAARSA18UMTA
ARSA25FMTAARSA25UMTA
AUSA40FRTAAUSA40URTA
AUSA50FRTAAUSA50URTA
AUSA18FRTAAUSA18URTA
AUSA25FRTAAUSA25URTA
AXSS24FHTB
AXSS18FHTA
Wall Mounted TypeWindow Type
ARSA40FMTBARSA40UMTB
ARSA50FMTBARSA50UMTB
ARSA60FHTBARSA60UHTB
Cassette Type
3
PRODUCT SUMMARY
New Energy Labelling Requirement SASO2663/2014
The number of stars displayed on the energy label. Available stars are between a
minimum of one and a maximum of ten. It is considered as an indication of the claimed
energy efficiency of a model at rated conditions. A higher star rating indicates a higher
energy efficiency. It is derived from the actual measured EER. Our models has reached
the highest energy efficiency level that is now shown on energy labels in Saudi Arabia.
ENERGY EFFICIENCY CLASSIFICATION
HYPER TROPICAL SPEC
R22 depletes the ozone layer, however, R410A is energy-efficient refrigerant with ODP “0”.
NEW REFRIGERANT
SASO2663/2014
R410A R22
EER
18.116.815.614.513.412.411.510 9.7 9 8.5
>>>>>>>>>>>>
EEREEREEREEREEREEREEREEREEREEREEREEREER
>
18.116.815.614.513.412.411.510 9.7 9 8.5 7.5 7.5
109.59
8.58
7.57654321
Energy rating classification Example of Label -Cooling only
Star RatingEER limits (rested value)
(Btu/h)/ w at T1
Temperature rise prevention device (thermal protector) installed
Gas leak protection and low voltage protection OLP (Over Load Protection) device installed
High-output torque motor Torque improved by increasing the thickness of the laminated core and
improving the coil winding
High durability vaneSurface hardness increased
High durability rolling piston Hardness improved by changing the material
High durability crankshaft used Hardness improved by adding a coating
1.Improvement of compressor drive materials for greater durability (Hardness increased).
2.Use of high efficiency, high torque motor
3.Complete protection functions against abnormal temperature rise and abnormal pressure rise
Main features
SUPER PROTECTION(for Split Type)
Enhancement of protection function
Strong blue finAdoption of strong blue fin provides strong protection against rust and salt damage.
Super powerMore capacity than old models under overload condition (52°C).(Window Type: 60°C)
Super low voltage operationOur Hyper Tropical Compressor can be operated even at low voltage.
Super Hi-EERHighly energy efficiency
Super quietSelect the lower noise level.
Designed by Fujitsu General the Japanese company whohas long term experience in air conditioning products
HYPER TROPICAL COMPRESSOR
• Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Cooling (SASO2681.T3) : Indoor temperature of 29°CDB / 19°CWB, and outdoor temperature of 46°CDB / 24°CWB. Heating (SASO2681.H1) : Indoor temperature of 20°CDB, and outdoor temperature of 7°CDB / 6°CWB• The protective function might work when using it in environment out of the temperature range mentioned above.• The maximum current is the maximum value when operated within the operation range.*:That specification is not fixed yet.
SPECIFICATIONS
V/Ø/Hz
WBtu/h
WA
Btu/hWI/h(pints/h)
WBtu/h
WA
Btu/hW
WWA
W/WA
m3/hmm
kg(lbs)mm
kg(lbs)
Model Name
Indoor unit(High)
Indoor unit
Outdoor unit
Indoor unitOutdoor unit
230/1/607
10,26035,0003,04013.4
11.51
*
8,94030,5003,68016.38.29
11,0003,54015.83.11
*1,410
340×1,150×28017(37)
1290×900×330106(233)
ASSA36UETAAOSA36UETAS
230/1/607
10,26035,0003,04013.4
11.51
*
8,94030,5003,68016.38.29
*1,410
340×1,150×28017(37)
1290×900×330109(240)
ASSA36FETAAOSA36FETAS
230/1/607.5
8,06027,5002,39010.5
11.512.6(4.6)
7,03024,0002,89012.78.30
8,1502,34010.2
16.51,350
340×1,150×28018(39)
914×970×37079(174)
ASSA30UMTAAOSA30UMTAS
230/1/607
8,06027,5002,39010.5
11.512.6(4.6)
7,03024,0002,89012.78.30
16.51,350
340×1,150×28018(39)
914×970×37077(169)
ASSA30FMTAAOSA30FMTAS
230/1/607
6,60022,6001,960
8.711.53
2.5(4.4)
5,70019,5002,35010.48.30
6,9501,950
8.63.5618.5
1,150320×998×238
15(33)830×900×330
64(141)
ASSA24UMTAAOSA24UMTAH
230/1/607
6,60022,6001,960
8.711.53
2.5(4.4)
5,70019,5002,35010.48.30
18.51,150
320×998×23815(33)
830×900×33064(141)
ASSA24FMTAAOSA24FMTAH
230/1/607.5
5,35018,3001,590
7.411.51
2.0(3.5)
4,57015,6001,880
8.48.30
5,4501,560
7.23.4915.0985
320×998×23815(33)
830×900×33063(139)
ASSA18UMTAAOSA18UMTAH
230/1/607
5,45018,6001,610
7.411.55
1.9(3.3)
4,66015,9001,920
8.68.28
16.0985
320×998×23815(33)
650×830×32050(110)
ASSA18FMTAAOSA18FMTAH
Power SourceEnergy LabelCooling (T1 condition)
Capacity
Input PowerCurrentEERMoisture Removal
Cooling (T3 condition)
Capacity
Input PowerCurrentEER
Heating (H1 condition)CapacityInput PowerCurrentCOP
Max. Running Current (Cooling)Airflow Rate
DimensionsH×W×D
Weight
4
Cooling
ASSA36FETACooling/Heating
ASSA36UETA
Cooling
ASSA30FMTACooling/Heating
ASSA30UMTA
Cooling
ASSA24FMTACooling/Heating
ASSA24UMTA
Cooling/Heating
ASSA18UMTACooling
ASSA18FMTA ASSA24UMTA ASSA24FMTAASSA18UMTA
ForASSA18UMTA ASSA24FMTA ASSA24UMTA
ForASSA18FMTA
ASSA18FMTA
Handy Type
Handy Type MODE SWING
SET
SET
TIMER
SLEEP
START/STOP
TEST RUNTTT RESETCLOCK ADJUST
FANFAN
TEMP
TEMP
NEWNEW
NEWNEW
ASSA30UMTAASSA30FMTA
ForASSA30FMTAASSA30UMTA
ASSA36UETAASSA36FETA
ForASSA36FETAASSA36UETA
TENTATIVE
5
Powerful Cooling
Super High
High
Med
Low
Quiet
5 speed
+
*One touch powerful cooling mode: Continuous operation for 30 minutes at maximum air volume
10.19 Btu/hW
11.51 Btu/hW13% up
42% up
22,900 Btu/h
24,000 Btu/h5% up
Powerful
High
Med
Low
Quiet
4 speed
+
Powerful mode(30 / 36 class)
15m 25m
than current powerful mode
20% up
Airflow
NEW model Current model
25m!
Temperature °C22.0 23.0 24.0 25.0 26.0 27.0
10m
10m
60cm
2.5m
Indoor temperature of 27°C DB, and outdoor temperature of 35°CDBSetting temperature:24°CDB, High airflow mode, 30 class CFD simulation results after 250 seconds from the start.
than current model
18% faster!
Reach the setting temp.
NEW model Current model
Powerful mode(30 / 36 class)
15m 25m
25m!
Reach thesetting temp.
NEW model Current model
(Btu/h, 230V, 60Hz, T3 condition)
NEW model
(Btu/h, 220V, 60Hz, T3 condition)
Current model
(Btu/hW, 230V, 60Hz, T1 condition)
NEW model
(Btu/hW, 220V, 60Hz, T1 condition)
Current model
30 cooling model
30 cooling model
30 Heat & Cool model
8.10 Btu/hW
11.51 Btu/hW
WALL MOUNTED TYPE
Long-reach airflow up to 25m is provided by optimized airflow design.
Powerful airflow
5-Speed fan control with added Powerful Cooling mode is provided.
* 30 / 36 class
More powerful fan speed control
Higher cooling capacity is achieved at the ambient temperature of 52°C condition.
Powerful cooling
New models accelerate to cool air quicker to reach the setting temperature in the entire
room than the current models do.
Faster cooling
Higher EER is achieved by the new technolo-gies and new refrigerant.
High energy saving
• Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Cooling (SASO2681.T3) : Indoor temperature of 29°CDB / 19°CWB, and outdoor temperature of 46°CDB / 24°CWB. Heating (SASO2681.H1) : Indoor temperature of 20°CDB, and outdoor temperature of 7°CDB / 6°CWB• The protective function might work when using it in environment out of the temperature range mentioned above.• The maximum current is the maximum value when operated within the operation range.
SPECIFICATIONS
V/Ø/Hz
WBtu/h
WA
Btu/hWI/h(pints/h)
WBtu/h
WA
Btu/hW
WWA
W/WA
m3/hmm
kg(lbs)mm
kg(lbs)
Model Name
Indoor unit(High)
Indoor unit
Outdoor unit
Indoor unitOutdoor unit
400/3/607
15,20052,0004,520
7.911.50
3.4(6.0)
13,00044,4005,360
9.28.28
14,6003,850
7.33.7914.5
3,350360×1,400×850
67(147)1,290×900×330
106(233)
ARSA60UHTBAOSA60URTBS
400/3/607
15,20052,0004,520
7.911.50
3.4(6.0)
13,00044,4005,360
9.28.28
14.53,350
360×1,400×85067(147)
1,290×900×330105(231)
ARSA60FHTBAOSA60FRTBS
400/3/607
12,40042,4003,680
6.311.52
3.2(5.6)
11,20038,1004,600
7.58.28
12,7003,350
5.83.7911.5
2,500300×1,400×700
44(97)1,290×900×330
102(224)
ARSA50UMTBAOSA50URTBS
400/3/607
12,40042,4003,680
6.311.52
3.2(5.6)
11,20038,1004,600
7.58.28
11.52,500
300×1,400×70044(97)
1,290×900×330100(220)
ARSA50FMTBAOSA50FRTBS
230/1/607
11,00037,5003,26015.0
11.503.1(5.5)
9,67033,0003,98018.58.29
11,3003,15014.53.5923.0
2,000300×1,400×700
44(97)1,290×900×330
105(232)
ARSA40UMTBAOSA40UBTBS
230/1/607
11,00037,5003,26015.0
11.503.1(5.5)
9,67033,0003,98018.58.29
23.02,000
300×1,400×70044(97)
1,290×900×330103(227)
ARSA40FMTBAOSA40FRTBS
230/1/607
6,70022,9001,990
8.811.51
2.3(4.0)
5,80019,8002,39010.58.28
6,9001,900
8.63.6318.5
1,200270×1,135×700
38(84)830×900×330
65(143)
ARSA25UMTAAOSA25UBTAH
230/1/607
6,70022,9001,990
8.811.51
2.3(4.0)
5,80019,8002,39010.58.28
18.51,200
270×1,135×70038(84)
830×900×33065(143)
ARSA25FMTAAOSA25FBTAH
230/1/607
5,35018,3001,590
7.411.51
1.5(2.6)
4,63015,8001,900
8.68.32
5,3001,550
7.03.4215.0
1,050270×1,135×700
38(84)830×900×330
64(141)
ARSA18UMTA AOSA18UBTAH
230/1/607
5,45018,7001,620
7.411.54
1.6(2.8)
4,75016,2001,950
8.78.31
16.01,050
270×1,135×70038(84)
650×830×32050(110)
ARSA18FMTAAOSA18FBTAH
Power SourceEnergy LabelCooling (T1 condition)
Capacity
Input PowerCurrentEERMoisture Removal
Cooling (T3 condition)
Capacity
Input PowerCurrentEER
Heating (H1 condition)CapacityInput PowerCurrentCOP
Max. Running Current (Cooling)Airflow Rate
DimensionsH×W×D
Weight
6
Wired Type(With Weekly Timer)
Wired Type(With Weekly Timer)
Wired Type(With Weekly Timer)
Cooling
ARSA25FMTACooling/Heating
ARSA25UMTA
Cooling/Heating
ARSA18UMTACooling
ARSA18FMTA ARSA25UMTA ARSA25FMTAARSA18UMTA
ForARSA18UMTA ARSA25FMTA ARSA25UMTA
ForARSA18FMTA
ARSA18FMTA
Cooling
ARSA50FMTBCooling/Heating
ARSA50UMTB
Cooling/Heating
ARSA40UMTBCooling
ARSA40FMTB
Cooling
ARSA60FHTBCooling/Heating
ARSA60UHTB
4-Step of the static pressures can be selected by the remote controller.(40 / 50 : 30, 60, 90, 120 Pa) (60 : 60, 100, 130, 160 Pa)
Assemble again in ceiling
Separate on floor
Assemble again in ceiling
7
DUCT TYPE
Air Stabilizer is provided to minimize loss of airflow which enables to reduce the power input of the fan motor.
* At Cooling High mode
with 2,000(m3/h)(40 class)
37dB*(A)
(40 / 50 class)
Max.120Pa(60 class)
Max.160Pa
with 2,500(m3/h)(50 class)
40dB*(A)with 3,350(m3/h)
(60 class)
41dB*(A)
(40 / 50 class)
22% up
Heat-ExchangerVolume
(60 class)
13% up
Heat-ExchangerVolume
V-shape heat exchangerAir StabilizerTop view
The lowest operating sound level with large air volume in cooling operation is provided among the competitors.
Low Operation Sound With Large Air Volume
The key technologies of V-Shape Heat-Exchanger and Air Stabilizer are provided as special features of this product.
Key Technologies For High Efficiency
The indoor unit is able to cover various duct designs thanks to the employment of DC fan motor.
Adjustable Static Pressure
As the indoor unit is too big to lift up to ceiling in the original structure, it can be separated on floor and
assembled it again in the ceiling.
Separated Indoor unit ( 60 model only)
• Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Cooling (SASO2681.T3) : Indoor temperature of 29°CDB / 19°CWB, and outdoor temperature of 46°CDB / 24°CWB. Heating (SASO2681.H1) : Indoor temperature of 20°CDB, and outdoor temperature of 7°CDB / 6°CWB• The protective function might work when using it in environment out of the temperature range mentioned above.• The maximum current is the maximum value when operated within the operation range.*:That specification is not fixed yet.
SPECIFICATIONS
V/Ø/Hz
WBtu/h
WA
Btu/hWI/h(pints/h)
WBtu/h
WA
Btu/hW
WWA
W/WA
m3/hmm
kg(lbs)mm
kg(lbs)
Model Name
Indoor unit(High)
Indoor unit
Outdoor unit
Indoor unitOutdoor unit
60/3/4007
12,00041,0003,560
6.111.52
*
10,65036,400
4.397.2
8.29
12,7003,350
5.83.79
*2,000
288×840×84029
1290×900×330102
AUSA50URTAAOSA50URTCS
60/3/4007
12,00041,0003,560
6.111.52
*
10,65036,400
4.397.2
8.294.39
*2,000
288×840×84029
1290×900×330100
AUSA50FRTAAOSA50FRTCS
60/1/2307
11,00037,5003,26015.0
11.50
*
9,67033,0003,98018.58.29
11,3003,15014.53.59
*1,900
288×840×84029
1290×900×330105
AUSA40URTAAOSA40UBTCS
60/1/2307
11,00037,5003,26015.0
11.50
*
9,67033,0003,98018.58.29
*1,900
288×840×84029
1290×900×330103
AUSA40FRTAAOSA40FBTCS
60/1/2307
6,70022,9001,990
8.811.51
*
5,80019,8002,39010.58.28
6,9001,900
8.63.63
*1,150
246×840×84024
830×900×33065
AUSA25URTAAOSA25UBTBH
60/1/2307
6,70022,9001,990
8.811.51
*
5,80019,8002,39010.58.28
*1,150
246×840×84024
830×900×33061
AUSA25FRTAAOSA25FBTBH
60/1/2307
5,35018,3001,590
7.411.51
*
4,63015,8001,900
8.68.32
5,3001,550
7.03.42
*1,050
246×840×84024
650×830×32052
AUSA18URTAAOSA18UBTBH
60/1/2307
5,45018,7001,620
7.411.54
*
4,75016,2001,950
8.78.31
*1,050
246×840×84024
650×830×32050
AUSA18FRTAAOSA18FBTBH
Power SourceEnergy LabelCooling (T1 condition)
Capacity
Input PowerCurrentEERMoisture Removal
Cooling (T3 condition)
Capacity
Input PowerCurrentEER
Heating (H1 condition)CapacityInput PowerCurrentCOP
Max. Running Current (Cooling)Airflow Rate
DimensionsH×W×D
Weight
8
Cooling
AUSA25FRTACooling/Heating
AUSA25URTA
Cooling
AUSA18FRTACooling/Heating
AUSA18URTA
NEWNEW
NEWNEW
Cooling
AUSA50FRTACooling/Heating
AUSA50URTA
Cooling
AUSA40FRTACooling/Heating
AUSA40URTA
NEWNEW
NEWNEW
AUSA25URTA AUSA25FRTAAUSA18URTA
ForAUSA18URTA AUSA25FRTA AUSA25URTA
ForAUSA18FRTA
AUSA18FRTA
Wired Type
Wired Type
TENTATIVE
9
CASSETTE TYPE
*Option Wired RC (Touch Panel) only
* Comfortable air conditioning by preventing direct blowing of cold air and by providing swinging air flow simultaneously
*Efficient air conditioning in accordance with the room layout
New cassette series have been achieved quiet operation and large air volume by unique circular flow design and offer quiet
comfortable activities.
Quiet operation and Large air volume
Each louver can be set individually by Touch Panel Wired Remote Controller to enjoy the comfort of different directional
airflows according to various room layouts.
Individual louver control(Option)
New cassette series have been achieved 7-Star in SASO.High energy efficiency operation can be done.
ALL 7-Star models
ASUA**URTA
50402518
11.51 11.50
18
11.51 11.52
AUSA**FRTA
50402518
11.51 11.50
18
11.54 11.52
T1(Btu/hW)
AUSA**F(U)RTAAUSA**F(U)RTA
5040251818 25 400 50
43
33
44
35
48
44
4946
50402518188 25 400 500
640
1050 1100 1150
1500
19001650
2000
Hi(dB) Hi(m3/h)
NEW model Current model
Comfortable!
Ø7mm high density heat exchanger
New DC fan motor
High efficient turbo fan
Seamless airflow louver
Achieve a comfortable air conditioning spread to every corner of the room by
circular flow & wide vertical airflow.
Uniform temperature air conditioning
New Cassette type realizes Circular Flow to blow large airflow in 360º direction by mounting high performance DC fan motor,
new turbo fan and unique seamless airflow louver design.
Unique Circular Flow design
10
Feature
Moisture Removal
Double Swing Automatic
Automatic Louvers
Auto Shut Louvers
Automatic fan speed
Auto Restart
Sleep Timer
Program Timer
Weekly Timer
Connectable Distributing Duct
Connectable Fresh Air Duct
Powerful Mode
Economy Mode
ARSA25FMTA ARSA25UMTAARSA18FMTA ARSA18UMTA ASSA18FMTA ASSA18UMTA
ASSA24FMTA ASSA24UMTAASSA30FMTA ASSA30UMTAASSA36FETA ASSA36UETA
ARSA40FMTB ARSA40UMTBARSA50FMTB ARSA50UMTBARSA60FHTB ARSA60UHTB
AUSA18FRTA AUSA18URTAAUSA25FRTA AUSA25URTAAUSA40FRTA AUSA40URTAAUSA50FRTA AUSA50URTA
Model
Program TimerThis digital timer allows selection of one of four options: ON, OFF, ON OFF or OFF ON
Auto RestartIn the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before once the power supply is restored.
Economy ModeThermostat setting automatically changesaccording to the temperature to avoidunnecessary cooling and heating.
Moisture RemovalThe computer effectively dehumidifies the air.
Double Swing AutomaticComplex swing action of louvers enables automatically to swing both horizontal and vertical directions.
Auto-Shut LouversThe auto shut louvers close or open automatically when the unit stops or starts.
Weekly TimerDifferent on-off times can be set for each day.
Powerful ModeOperates at maximum air flow in the cool and fan operation modes, and quickly makes the room comfortable.
Sleep Timer The micro-computer gradually changes the room temperature automatically to help you enjoy a comfortable night's sleep.
Automatic LouversThe position of the louvers is set automatically to match the operating mode. The louvers can also be adjusted using the remote controller.
Automatic fan speedThe micro-computer automatically adjusts the airflow effectively and properly according to the changes of room temperature.
FEATURE SUMMARY FOR SPLIT TYPE
EXPLANATION OF FEATURES
• Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Cooling (SASO2681.T3) : Indoor temperature of 29°CDB / 19°CWB, and outdoor temperature of 46°CDB / 24°CWB.• The protective function might work when using it in environment out of the temperature range mentioned above.• The maximum current is the maximum value when operated within the operation range.
SPECIFICATIONS
V/Ø/Hz
WBtu/h
WA
Btu/hWI/h(pints/h)
WBtu/h
WA
Btu/hWA
m3/hmm
kg(lbs)mm
kg(lbs)
Model Name
Indoor unit(High)
Indoor unit
Outdoor unit
Indoor unitOutdoor unit
60/1/2304
7,06024,1002,63011.69.16
2.9(5.1)
5,80019,8003,13014.06.3318
1,060455×670×710
63(137)
AXSS24FHTB
60/1/2305
5,28018,0001,810
8.19.94
2.0(3.5)
4,57015,6002,180
9.87.1613
940455×670×710
56(123)
AXSS18FHTA
Power SourceEnergy LabelCooling (T1 condition)
Capacity
Input PowerCurrentEERMoisture Removal
Cooling (T3 condition)
Capacity
Input PowerCurrentEER
Max. Running Current (Cooling)Airflow Rate
DimensionsH×W×D
Weight
11
Cooling
AXSS24FHTB
Cooling
AXSS18FHTA
WhiteFront Panel Colour
Energy saving and high performance are realized even at high outdoor temperature by using new refrigerant R410A and mounting
large heat exchanger and new efficient rotary compressor.
R410A
Optional parts
WINDOW TYPE
Wired Remote ControllerUTY-RNNGM
Communication KitUTY-XCBXZ3(for 30/36)
External Connect KitUTY-XWZXZ5(for 30/36)
For WALL MOUNTED TYPE
Wide PanelUTG-AKXA-W
IR Receiver UnitUTY-LBTGC
Wired Remote ControllerUTY-RNRGZ1
Panel SpacerUTG-BKXA-W
Air Outlet Shutter PlateUTR-YDZK
External Input and Output PCBUTY-XCSX
External Input and Output PCB BoxUTZ-GXRA
External Connect KitUTY-XWZXZG
For CASSETTE TYPE
Communication KitUTY-TWRXZ1
Insulation for High HumidityUTZ-KXRA
Panel spacer
242 mmIndoor unit950
Panel 600(mm)
600
Remote Sensor UnitUTY-XSZX
Long Life FilterUTD-LF25NA(for 18/25)
UTD-LFNA(for 40/50)UTD-LFKA(for 60)
Flange (Round)UTD-RF204(for 18/25)
Flange (Square)UTD-SF045T(for 18/25)
Drain Pump UnitUTZ-PX1NAA(for 40/50/60)
Drain Pump UnitUTZ-PX1NBA(for 18/25)
External Input and Output PCBUTY-XCSX(for 60)
External Input and Output PCB BracketUTZ-GXNA(for 60)
External Connect KitUTY-XWZXZG(for 60)
External Connect SetUTD-ECS5A(for 18/25/40/50)
For DUCT TYPE
Distributed by:
•“ ” is a worldwide trademark or registered trademark of FUJITSU GENERAL LIMITED in Japan and other countries or areas.•The colors may be different from the actual colors because this catalog is printed matter.•Specifications and design subject to change without notice for further improvement. Please check with your dealer.
Copyright© 2013-2015 Fujitsu General Limited. All rights reserved. 3MGS06-1602EA
Fujitsu General (Shanghai) Co., Ltd.
ISO 9001Certified number: 01 100 79269
ISO 14001Certified number: CNBJ311153-UK
Fujitsu General (Thailand) Co., Ltd.
ISO 9001Certified number: 01 100 89394
ISO 14001Certified number: 01 104 9245/01
E-Mail: [email protected]