product catalog 2019 · 2019-05-30 · electric street lights were created and by 1890, over...

16
PRODUCT CATALOG 2019

Upload: others

Post on 06-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

PRODUCT CATALOG 2019

Page 2: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

Product Line

4-5

6-7

8-9

10-11

12-13

14-15

About Us 3

LED FixturesExplosion Proof | Hazardous Area | industrial location

RetrusTM Family

ProAirTM Family

OppryTM Family

PlafondTM Family

LED FixturesExplosion Proof | Hazardous Area | industrial location

TraffExTM Family

TablExTM Family

2

Page 3: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

4-5

6-7

8-9

10-11

12-13

14-15

about us

3

ARCUS, known internationally as Electrolooch, was born out of necessity in 1889, a time when innovation

completely changed the way we used lighting in ourdaily lives. In 1876 Russian inventor and entrepreneur,

Pavel Yablochkov created a device called the Yablochkov Candle. It was based on the Carbon Arc Lamp,

however Yablochkov improved upon it. It was first demonstrated for street and theatre illumination during

the Paris Exhibition of 1878, notably on the Avenuede l'Opéra. Because of the Yablochkov Candle the first

electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the

United States. Eventually, they popped up all over the world.

The ushering in of electric light created a mass desire as lighting went from gas lanterns to ARC lighting,

with the eventual creation from many inventors the most notable Thomas Edison of the modern day

incandescent light bulb. With the creation of electric power plants and electric generators, the demand

for residential, commercial and industrial lighting was booming. Our unsurpassed devotion to engineering

superior light fixtures emerged during that revolutionary transition from darkness to light.

Leading the way in industrial light manufacturing, Electrolooch manufactured light fixtures for the first

Subway Stations, Train Stations, Military and Government Facilities through-out Eastern Europe.

Electrolooch is still in business over 120 years later and has named its North American Subsidiary “ARCUS”

to champion the accomplishments of the inventor and electrical engineer Pavel Yablochkov.

At ARCUS, innovation and imagination are as highly valuedas product reliability and quality. We continue

to pursue new and better ways of engineering and designing to produce 21st century technology solutions

and collaborating with our customers around the world to insure the best product for their commercial

and industrial applications. ARCUS is evolving the technology of design and manufacturing to produce

the most efficient, high quality industrial LED lighting products and fixtures. We have a wide range of

solutions for most any need.

Page 4: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

arcuslight.com

Retrustm family

Specification:

Retrus™ is direct replacements for Crouse-Hinds®, Appleton®, Holophane®, Killark® and General Electric® model fixtures utilizing the existing top hat hardware.

Housing:Die cast aluminum

Mounting Options:Uses Existing Hardware

Ingress Protection:IP66 | NEMA4X

Hazardous classification:Class I Div. 2, Groups A, B, C, D T5

Class I Zone 2 Group IIС T5

Class II Div.1 and 2 Groups E, F and G T5

Class II Zone 20, 21or 22 Group IIB T5

Class III

4

Retrus™ was created for ease installation.

Extremely light weight (9 lbs) makes changing an

existing Crouse-Hinds, Appleton, Holophane,

Killark or GE fixture simple. Our kits use one screw

and have 3 wires, making upgrading the old

MH/HPS lighting to ARCUS fixture with XTE CREE

LED’s extremely quick. Utilizing your existing base,

our Retrofit installs in minutes. With a powerrange

of 20W, 36W, 60W and 80W, you are covered from

2300-9,200 lumens. Retrus™ is used for waste

water facility upgrades, petro-chemical

manufacturing and refining, industrial

manufacturing. Voltage input range from 120-277

VAC with optional 347-480 VAC. The 80W models

body is slightly larger to effectively produce an

efficient heat sink ensuring our T5 heat rating. All

Retrus™ models have an enamel finish designed for

harsh and corrosive environments. NEMA4x rated

for marine environments -40°C<t<+55°C for

extreme cold storage applications with IP66

protection.

Page 5: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

Hazardous Area and Industrial Location LED Retrofits

retrusTM

Wattage:20W | 36W | 60W | 80W

Lumen Output:2300 | 5200 | 7200 | 9200 Lm

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120-277 VAC, 347 – 480 VАС Optional

Ambient Temperature Rating:-40°C<t<+55°C

Measurements:11.5 x 5.0 in

Weight:6.5 lbs to 11 lbs

5

retrustm for HLHL RETRUStm for ILIL

Page 6: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

arcuslight.com

proairtm family

Specification:

ProAir™ Series fixtures are extremely efficient and robust fixtures for the Hazardous Lighting Industry and Industrial Locations. High-Bay, Flood, Area, and Spot mounting configurations. 7,800-13,000 Lumens.

Housing:Marine grade extruded aluminum

Mounting Options:Swivel Bracket, Ceiling Mount, Wall Mount,

Conduit Mount, Pendant Mount, Stanchion Mount

Ingress Protection:IP66 | NEMA4X

Hazardous classification:Class I Divsion 2, Groups A, B, C, D T5

1Ex d IIC T5 | 1Ex d IIC T6

6

ProAir™ series luminaires are designed for lighting

hazardous areas in spot, flood or high-bay

configurations. ProAir™ is extremely efficient. With

increased lumen output and lower wattage when

compared to competition making ProAir™ the

obvious choice for Hazloc and industrial lighting.

Drivers are fully potted for vibration resistance

and a power range of 60W, 80W, 100W and 120W

watts. In models with 100 and 120 Watt have a

specifically engineered body for more effective

heat disbursement extending the life of driver and

LED's. Voltage input 120-277 VAC and 0-10 V

dimming. All ProAir™ models have an enamel finish

designed for harsh and corrosive environments.

NEMA4X rated for marine environments

-40°C<t<+55°C for extreme cold storage

applications with IP66 protection.

Page 7: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

proairTM

Hazardous Area and Industrial location LED Flood light

Wattage:60W | 80W

Lumen Output:7800 | 9900 Lm

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120-277 VAC and 0-10 V dimming

Custom Voltage Upon RequestAmbient Temperature Rating:-40°C<t<+55°C

Measurements:16.5 x 9 x 5.6 in

Weight:16 lbs

proairTM

Wattage:100W | 120W

Lumen Output:12000 | 13000 Lm

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120-277 VAC and 0-10 V dimming

Custom Voltage Upon RequestAmbient Temperature Rating:-40°C<t<+55°C

Measurements:16.7 x 9.9 x 5.6 in

Weight:20 lbs

7

proairtmILHL proairtmILHL

Hazardous classification:Class I Divsion 2, Groups A, B, C, D T5

1Ex d IIC T5 | 1Ex d IIC T6

Page 8: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

arcuslight.com

Opprytm family

Specification:

Oppry™ series fixtures are designed to be direct replacement with the most common Hazardous Area fixtures producing 2,300-9,200 lumens.

Housing:Die cast aluminum

Mounting Options:Swivel Bracket, Pendant Mount

Ingress Protection:IР66 | NEMA4X

Hazardous classification:Class I Div. 1 Groups С, D T6

Class I Zone 1 Groups IIB T6

Class I Div. 2, Groups A, B, C, D T5

Class I Zone 2 Group IIС T5

Class II Div.1 and 2 Groups E, F and G T5

Class II Zone 20, 21or 22 Group IIB T5

Class III

1Ex d IIC T5 | 1Ex d IIC T6

8

Oppry™ perfectly solves all the problems with-in

the hazardous and explosion proof lighting area.

Size, durability, light disbursement, and quality.

Unequaled in size to power, the Oppry™ is used on

terminals and loading platforms, in wastewater

facilities, industrial manufacturing and

petro-chemcial refineries, and is perfect for most

low bay applications. With a range of 36W, 60W

and 80W and optional voltage input range from

120-277 VAC, 347-480 VAC.

Mounting can be direct conduit, junction box, or

swivel mounting. In the 60 W and 80 W models the

body is slightly larger to effectively produce an

efficient heat sink ensuring our T5-T6 heat rating.

Oppry™ has an enamel finish that is designed for

harsh and corrosive environments. NEMA4X rated

for marine environments -40°C<t<+55°C for

extreme cold storage applications with IP66

protection

arcuslight.com

Housing:Die cast aluminum

Mounting Options:Uses Existing Hardware

Ingress Protection:IP66 | NEMA4X

Hazardous classification:Class I Div. 2, Groups A, B, C, D T5

Class I Zone 2 Group IIС T5

Class II Div.1 and 2 Groups E, F and G T5

Class II Zone 20, 21or 22 Group IIB T5

Class III

Wattage:100W | 120W

Lumen Output:12000 | 13000 Lm

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120-277 VAC and 0-10 V dimming

Custom Voltage Upon RequestAmbient Temperature Rating:-40°C<t<+55°C

Measurements:16.7 x 9.9 x 5.6 in

Weight:20 lbs

Page 9: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

Opprytm

Explosion Proof | Hazardous Area and Industrial Location LED Lowbay Light

Wattage:36W | 60W | 80W

Lumen Output:5200 | 7600 | 9200 Lm

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120-277 VAC, 347 – 480 VАС

Optional

Ambient Temperature Rating:-40°C<t<+55°C

Measurements:15-40W 9.45 x 5.8 in

50-60W 6.90 x 5.9 in

Weight:5.3- 11.0 lbs

9

opprytm for ex opprytm for HL opprytm for ILEX ILHL

Wattage:20W | 36W | 60W | 80W

Lumen Output:2300 | 5200 | 7200 | 9200 Lm

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120-277 VAC, 347 – 480 VАС Optional

Ambient Temperature Rating:-40°C<t<+55°C

Measurements:11.5 x 5.0 in

Weight:6.5 lbs to 11 lbs

Page 10: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

arcuslight.com

Plafondtm family

Specification:

Plafond™ series fixtures are a unique group fixtures engineered specifically for its compact size, high lumen output and low wattage. Ideal for modular skid & storage building industry, however any area with requiring 2,500-2,900 lumens.

Housing:Die cast aluminum

Mounting Options:Swivel Bracket, Ceiling Mount, Wall Mount

Ingress Protection:IP66 | NEMA4X

Hazardous classification:Class I Div. 1 Groups С, D T6

Class I Zone 1 Groups IIB T6

Class I Div. 2, Groups A, B, C, D T5

Class I Zone 2 Group IIС T5

Class II Div.1 and 2 Groups E, F and G T5

Class II Zone 20, 21or 22 Group IIB T5

Class III

1Ex d IIC T5

10

Extremely low profile and small size and weight. Its

uniform crispwhite light, specially engineered for

lighting in hazardous areaswhere head room and

space are a factor. Applications includetunnels,

confined spaces, modular skids, storage units,

mechanical rooms and buildings, elevator shaſts,

and piping and conduit runsand ships and vessels.

At 2.5 lbs its the lightest fixture in its class. These

luminaires exceed all expectations when it comes

to providing a convenient and compact light

with-in work areas within the Hazardous Lighting

Industry.

The standard PlafondTM is 20 watts and

voltageinput of 120-277 VAC. Mounting can be

inline on conduit, flat surface, or swivel universal

mounting. Plafond™ enclosures are NEMA4X rated

for marine environment -40°C<t<+45°C for

extreme cold storage applications with IP66

protection.

arcuslight.com

Housing:Marine grade extruded aluminum

Mounting Options:Swivel Bracket, Ceiling Mount, Wall Mount,

Conduit Mount, Pendant Mount, Stanchion Mount

Ingress Protection:IP66 | NEMA4X

Hazardous classification:Class I Divsion 2, Groups A, B, C, D T5

1Ex d IIC T5 | 1Ex d IIC T6

Page 11: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

Hazardous classification:Class I Div. 1 Groups С, D T6

Class I Zone 1 Groups IIB T6

Class I Div. 2, Groups A, B, C, D T5

Class I Zone 2 Group IIС T5

Class II Div.1 and 2 Groups E, F and G T5

Class II Zone 20, 21or 22 Group IIB T5

Class III

1Ex d IIC T5

Plafondtm

Explosion Proof | Hazardous Area and Industrial location LED Area Light

Wattage:20W

Lumen Output:2500 | 2900 Lm

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120 – 277 VАС

Ambient Temperature Rating:-40°C<t<+45°C

Measurements:2.6x5.9x5.9 in

Weight:2.5 lbs

11

Plafondtm for ex Plafondtm for HL Plafondtm for ILEX ILHL

Wattage:60W | 80W

Lumen Output:7800 | 9900 Lm

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120-277 VAC and 0-10 V dimming

Custom Voltage Upon RequestAmbient Temperature Rating:-40°C<t<+55°C

Measurements:16.5 x 9 x 5.6 in

Weight:16 lbs

Wattage:100W | 120W

Lumen Output:12000 | 13000 Lm

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120-277 VAC and 0-10 V dimming

Custom Voltage Upon RequestAmbient Temperature Rating:-40°C<t<+55°C

Measurements:16.7 x 9.9 x 5.6 in

Weight:20 lbs

Hazardous classification:Class I Divsion 2, Groups A, B, C, D T5

1Ex d IIC T5 | 1Ex d IIC T6

Page 12: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

arcuslight.com

Housing:Die cast aluminum

Mounting Options:Swivel Bracket, Pendant Mount

Ingress Protection:IР66 | NEMA4X

Hazardous classification:Class I Div. 1 Groups С, D T6

Class I Zone 1 Groups IIB T6

Class I Div. 2, Groups A, B, C, D T5

Class I Zone 2 Group IIС T5

Class II Div.1 and 2 Groups E, F and G T5

Class II Zone 20, 21or 22 Group IIB T5

Class III

1Ex d IIC T5 | 1Ex d IIC T6

Wattage:100W | 120W

Lumen Output:12000 | 13000 Lm

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120-277 VAC and 0-10 V dimming

Custom Voltage Upon RequestAmbient Temperature Rating:-40°C<t<+55°C

Measurements:16.7 x 9.9 x 5.6 in

Weight:20 lbs

arcuslight.com

TraffExtm family

Specification:

TraffEx™ utilizes Plaflond™ lights, with high quality colored LED's. Installed in our Propriety mounting assembly.

Housing:Die cast aluminum

Mounting Options:Swivel Bracket, Ceiling Mount, Wall Mount,

Conduit Mount, Pendant Mount, Stanchion Mount

Ingress Protection:IP66 | NEMA4X

Hazardous classification:Class I Division 2 Group A-D T5

Class I Zone 2 Group IIC T5

Class II Division 1, 2 Group E-G T5

Class II Zone 20, 21, 22 Group IIB T5

CLASS III

1Ex d IIC T5 | 1Ex d IIC T6

12

TraffEx™ is used for traffic control within loading

platform and terminals, scales, oil and gas

processing industry, chemical and pharmaceutical

industries, and anywhere safety is a concern.

TraffEx™ provides an inherent feeling of safety by

triggering the RED, YELLOW, GREEN Traffic lights

used when operating a vehicle. TraffEx™ is

engineering modularly, and dependent on

need,will use one, two, three or four modules. Each

Light is based on Plafond enclosure and the CREE

XTE LED’s are colored to RED, YELLOW,GREEN

and BLUE. TraffEx™ was engineered with an enamel

finish designed for harsh and corrosive

environments. NEMA4X rated for marine

environments -40°C<t<+45°C for extreme cold

storage applications with IP66 protection.

Page 13: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

Wattage:36W | 60W | 80W

Lumen Output:5200 | 7600 | 9200 Lm

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120-277 VAC, 347 – 480 VАС

Optional

Ambient Temperature Rating:-40°C<t<+55°C

Measurements:15-40W 9.45 x 5.8 in

50-60W 6.90 x 5.9 in

Weight:5.3- 11.0 lbs

TraffExTM 30W

Explosion Proof | Hazardous Area and Industrial Location LED Traffic light

Wattage:2х15W

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120-277 VАС | 24 DC | 36 AC

Ambient Temperature Rating:-40°C<t<+45°C

Measurements:20 x 12 x 11.2 in

Weight:12.5 lbs

TraffExTM 45W

Wattage:3х15W

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120-277 VАС | 24 DC | 36 AC

Ambient Temperature Rating:-40°C<t<+45°C

Measurements:27.5 x 12 x 11.2 in

Weight:15 lbs

13

ILEX HL traffextm ILEX HL traffextm

Page 14: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

arcuslight.com

Housing:Die cast aluminum

Mounting Options:Swivel Bracket, Ceiling Mount, Wall Mount

Ingress Protection:IP66 | NEMA4X

Hazardous classification:Class I Div. 1 Groups С, D T6

Class I Zone 1 Groups IIB T6

Class I Div. 2, Groups A, B, C, D T5

Class I Zone 2 Group IIС T5

Class II Div.1 and 2 Groups E, F and G T5

Class II Zone 20, 21or 22 Group IIB T5

Class III

1Ex d IIC T5

Wattage:3х15W

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120-277 VАС | 24 DC | 36 AC

Ambient Temperature Rating:-40°C<t<+45°C

Measurements:27.5 x 12 x 11.2 in

Weight:15 lbs

arcuslight.com

TablExtm family

Specification:

TablEx™ was engineered to improve safety with visual alerting in hazardous area and explosion proof industry. Customizable inscriptions, and battery backup options.

Housing:Marine grade extruded aluminum

Mounting Options:Swivel Bracket, Ceiling Mount, Wall Mount,

Conduit Mount, Pendant Mount, Stanchion

Ingress Protection:IP66 | NEMA4X

Hazardous classification:Class I Div. 2, Groups A, B, C, D T5

Class I Zone 2 Group IIС T5

1Ex d IIC T6 X

14

TablEx™ was engineered to solve the problem of

visual alert in hazardous area and explosion proof

industry. TablEx™ is a luminous panel with

customizable inscriptions on the lens. (FIRE,

EXIT, EMERGENCY, GAS LEVELS) The display

backlight LEDs used are CREE XTE highly efficient

with increased service life. TablEx™ has two

modes: continuous and strobe with various

frequency 1.5 | 3.0 | 4.5 Hz.

In addition to 120-277 VAC, optional voltage

inputrange. TablEx™ is engineered with an

enamel finish designed for harsh and corrosive

environments. NEMA4x rated for marine

environments -40°C<t<+55°C for extreme cold

storage applications with IP67 protection.

Page 15: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

Hazardous classification:Class I Div. 1 Groups С, D T6

Class I Zone 1 Groups IIB T6

Class I Div. 2, Groups A, B, C, D T5

Class I Zone 2 Group IIС T5

Class II Div.1 and 2 Groups E, F and G T5

Class II Zone 20, 21or 22 Group IIB T5

Class III

1Ex d IIC T5

Wattage:20W

Lumen Output:2500 | 2900 Lm

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120 – 277 VАС

Ambient Temperature Rating:-40°C<t<+45°C

Measurements:2.6x5.9x5.9 in

Weight:2.5 lbs

Hazardous classification:Class I Div. 2, Groups A, B, C, D T5

Class I Zone 2 Group IIС T5

1Ex d IIC T6 X

tablexTM

Hazardous Area and Industrial Location LED Exit Sign

Wattage:10 W | 20 W

Warranty:5 years

LED Type:CREE | XT-E | S4

Voltage:120 – 277 VАС

Light mode:Constant | Strobe

Ambient Temperature Rating:-40°C<t<+55°C

Measurements:16.5 x 9 x 5.6 in

Weight:12.5 lbs

15

tablextmILHLtablextmILHL

Page 16: PRODUCT CATALOG 2019 · 2019-05-30 · electric street lights were created and by 1890, over 130,000 electric street lights were in operation in the United States. Eventually, they

contacts

+1 (858) 353 1073 [email protected]

arcuslight.com

arcuslight.com

Housing:Die cast aluminum

Mounting Options:Swivel Bracket, Ceiling Mount, Wall Mount,

Conduit Mount, Pendant Mount, Stanchion Mount

Ingress Protection:IP66 | NEMA4X

Hazardous classification:Class I Division 2 Group A-D T5

Class I Zone 2 Group IIC T5

Class II Division 1, 2 Group E-G T5

Class II Zone 20, 21, 22 Group IIB T5

CLASS III

1Ex d IIC T5 | 1Ex d IIC T6