PROCESS LEVEL ENERGY MANAGEMENT TEAM
ON ASH HANDLING PLANT
MEMBERS:
R K OJHA, LEADER
K V REDDI, MEMBER
ROMIT MOHAPATRA, MEMBER
DILIP DAS, MEMBER
![Page 3: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/3.jpg)
NALCO AT A GLANCE
CORPORATE OFFICE
BAUXITE MINES ALUMINA REFINERY ALUMINIUM SMELTER
CAPTIVE POWER PLANT
ROLLED PRODUCT UNIT PORT FACILITIES
WIND POWER PLANT SOLAR POWER PLANT
![Page 4: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/4.jpg)
SALIENT FEATURES
BAUXITE MINES: Area od deposit – 16Sq.KM Resource – 310 MT Capacity – 68.25 Lakh TPA Transport – 14.6KM long cable
belt conveyor
ALUMINA REFINERY: Capacity – 22.75 Lakh TPA Atmospheric pressure digestion Pre-desilication & inter-stage
cooling for higher productivity Co-generation –4X18.5MW power
ALUMINIUM SMELTER: Capacity – 4.60 Lakh TPA 180KW Cell technology Micro-processor based pot
regulation system Ingot, wire rod, billet, strip
casting
CAPTIVE POWER PLANT: Capacity – 1200 MW Micro-processor based burner
management system Automatic turbine run-up
system Specially designed barrel type
high pressure turbine
ROLLED PRODUCT UNIT: Capacity – 50000 MT/ annum Products – Cold rolled sheets, coils
from continuous caster route Technology – FATA Hunter of Italy
PORT FACILITIES: Location: Visakhapatnam Export - Alumina Import – Caustic Soda Mechanised storage and ship
handling facilities
WIND POWER PLANT: Capacity – 50.4 MW, A.P.,
commissioned in Dec’2012 Capacity – 47.6 MW, Rajastan,
commissioned in Jan’2014
SOLAR POWER PLANT: Capacity – 260 KW Commissioned roof top solar
power plant at Corporate Office
![Page 5: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/5.jpg)
ALUMINA REFINERY
ALUMINA MAKING PROCESS
STEAM GENERATION PROCESS
BOILERS: Make – M/s BHEL Capacity – 4 Boilers of 200TPH – 1 Boiler of 250TPH Type - VU40, Bi-drum, natural circulation, oil/ p.f. fired, fixed tangential corner fired
TURBOGENERATORS: Make – M/s BHEL Capacity – 4 TGs’ of 18.5MW Type - Extraction back pressure TG Higher cycle efficiency due to co-generation
![Page 6: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/6.jpg)
BOILER
AIR PRE-HEATER
ESP
AIR
FUEL
WET ASH SYSTEM
ASH POND
DM WATER
PROCESS FLOW DIAGRAM
STEAM
DRY ASH COLLECTION
FLY ASH SILO
CHIMNEY
FLUE GAS
PRAYASH QC
6
ECONOMISER
![Page 7: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/7.jpg)
WET ASH DISPOSAL SYSTEM
BLR #3
BLR #2
BLR #1
BLR #4
BLR #5
BOTTOM ASH HOPPER
LINE - 1 5 2 3 4 STAGE
1
STAGE 2
STAGE 3
STREAM#6
AIR
PREHEATER
ECONOMISER
BOILER BLOW DOWN
ESP
PRAYASH QC
7
STREAM#5
STREAM#4
STREAM#3
STREAM#2
STREAM#1
![Page 8: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/8.jpg)
ASH POND
ASH DISPOSAL PUMP HOUSE
ASH SLURRY PIT
ASH SLURRY PUMP
![Page 9: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/9.jpg)
UPGRADATION OF
ASH SLURRY PUMPS
![Page 10: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/10.jpg)
ASH DISPOSAL PUMP HOUSE
• NO. OF STREAMS : 03
• ASH SLURRY PUMPS: 09NOS
• SERIES PUMPING
• CAPACITY: 635M3/HR
• HEAD: 44MTRS
• MOTOR: 150KW
• NO. OF STREAMS : 03
• ASH SLURRY PUMPS: 09NOS
• SERIES PUMPING
• CAPACITY: 350M3/HR
• HEAD: 50MTRS
• MOTOR: 110KW
ADPH-I ADPH-II
![Page 11: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/11.jpg)
ADPH-I
• ORIGINAL PUMP
• EFFICIENCY : 67%
• POWER CONS : 120KW
• UPGRADED PUMP
• EFFICIENCY : 76%
• POWER CONS : 106KW
UPGRADATION OF ASH SLURRY PUMP IN
STREAM-1 OF OLD ADPH
![Page 12: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/12.jpg)
POWER SAVING
• INSTANTANEOUS POWER SAVING : 14KWH
• POWER SAVING PER DAY : 336KWH
• POWER SAVING PER ANNUM : 122640 KWH
• SAVING OF POWER @Rs 3.20/- : Rs 3,92,448/- (PER PUMP PER ANNUM)
• SAVING OF POWER FOR ONE STREAM:Rs 11,77,344 /- (PER ANNUM)
![Page 13: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/13.jpg)
CALCULATION OF PAY BACK PERIOD
• COST OF REPLACEMENT OF ONE PUMP : Rs 6,15,282/-
• COST OF REPLACEMENT OF ONE STREAM : Rs 18,45,846/-
• SAVING OF POWER FOR ONE STREAM:Rs 11,77,344 /- (PER ANNUM)
• PAY BACK PERIOD : 1.6 YEARS
THE PAY BACK PERIOD IS ABOUT ONE YEAR APART
FROM IMPROVED LIFE OF COMPONENTS
![Page 14: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/14.jpg)
EFFICIENCY OF PUMP = WATER HORSE POWER
SHAFT HORSE POWER
![Page 15: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/15.jpg)
REASON FOR INCREASE IN HYDRAULIC EFFICIENCY
• FLOW PATTERN CHANGED FROM RADIAL FLOW TO MIXED FLOW
• TWISTED VANE IMPELLER
• MODIFIED HYDRAULIC ASSEMBLY
![Page 16: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/16.jpg)
MIXED FLOW
TWISTED VANE IMPELLER
MODIFIED HYDRAULIC ASSEMBLY
![Page 17: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/17.jpg)
CONCLUSION
• EFFICIENCY INCREASED BY 9%
• POWER SAVING PER STREAM – 122.64 MW
• NET SAVING IN TERMS OF MONEY – Rs. 11,77,344 /-
![Page 18: PROCESS LEVEL ENERGY](https://reader033.vdocuments.mx/reader033/viewer/2022042421/6260046b2bfe6f78d72343fc/html5/thumbnails/18.jpg)