pro passivhausfenster gmbh, id:0399sl03...manufacturer: pro passivhausfenster gmbh, oberaudorf,...
TRANSCRIPT
CERTIFICATECertified Passive House Component
Passive House InstituteDr. Wolfgang Feist64283 Darmstadt
GermanyComponent-ID 0399sl03 valid until 31st December 2020
www.passivehouse.com
Category: Sliding DoorManufacturer: pro Passivhausfenster GmbH,
Oberaudorf,Germany
Product name: smartwin sliding
This certificate was awarded based on the followingcriteria for the cool, temperate climate zone
Comfort USL = 0.78 ≤ 0.80 W/(m2 K)USL,installed ≤ 0.85 W/(m2 K)with Ug = 0.70 W/(m2 K)
Hygiene fRsi=0.25 ≥ 0.70
CERTIFIEDCOMPONENTPassive House Institute
cool, temperate climate
phAPassive House
efficiency class phE phD phC phB phA
pro Passivhausfenster GmbHMartin-Greif-Straße 20, 83080 Oberaudorf, GermanyT +49 (0)8033 / 304098 |B [email protected] | Í http://www.propassivhausfenster.net |
20 o
C
18 o
C
16 o
C
14 o
C
12 o
C
10 o
C
8 o
C
6 o
C
4 o
C
2 o
C
0 o
C
-2 o
C
-4 o
C
-6 o
C
-8 o
C
-10 o
C
Calculation model Isothermal
Description
Timber Window frame, rainprotected by alluminium cladding, insulated by woodfibre board (0,04 and0,05W/(mK)). Used Pane: 48 mm (4/18/4/18/4), intersection of the glass: 15 mm.
Explanation
The window U-values were calculated for the test window size of 2.40 m× 2.50 m with Ug =0.70 W/(m2 K). If a higher quality glazing is used, the window U-values will improve as follows:
Glazing Ug = 0.70 0.66 0.60 0.54 W/(m2 K)↓ ↓ ↓ ↓
Window USL = 0.78 0.75 0.70 0.65 W/(m2 K)
Transparent building components are classified into efficiency classes depending on the heat lossesthrough the opaque part. The frame U-Values, frame widths, thermal bridges at the glazing edge, andthe glazing edge lengths are included in these heat losses. A more detailed report of the calculationsperformed in the context of certification is available from the manufacturer.The Passive House Institute has defined international component criteria for seven climate zones.In principle, components which have been certified for climate zones with higher requirements mayalso be used in climates with less stringent requirements. In a particular climate zone it may makesense to use a component of a higher thermal quality which has been certified for a climate zonewith more stringent requirements.
Further information relating to certificationcan be found on www.passivehouse.com and passipedia.org.
2/5Component-ID: 0399sl03
www.passivehouse.com
Frame width U-value frame Ψ -panel edge Temp. Factorbf Uf Ψg fRsi=0.25
Framevalues mm W/(m2 K) W/(m K) [-]
Top (to) 92 0.84 0.022 0.70
Side (s) 85 0.81 0.022 0.70
Topfixed
(tof) 86 0.53 0.023 0.70
Sidefixed
(sf) 86 0.53 0.023 0.70
Bottomfixed
(bof) 108 0.66 0.022 0.70
Threshold (th) 117 1.08 0.025 0.70
Mullion1 casement
(m1) 110 1.29 0.023 0.70
Spacer: SWISSPACER V Secondary seal: -
Threshold
bf = 117.00 mmUf = 1.08 W/(m2 K)Ψg = 0.025 W/(m K)fRsi = 0.70
Mullion1 casement
bf = 110.00 mmUf = 1.29 W/(m2 K)Ψg = 0.023 W/(m K)fRsi = 0.70
3/5 smartwin sliding
www.passivehouse.com
Exterior insulation and finishing s. (EIFS)bottom (operable)
U1 = 0.13 U2 = 0.14 [W/(m2 K)]
Ψinstall = 0.06 W/(m K)
Exterior insulation and finishing s (EIFS)side (fixed glazed)
U1 = 0.13 [W/(m2 K)]
Ψinstall = −0.00 W/(m K)
Exterior insulation and finishing system(EIFS) bottom (fixed)
U1 = 0.13 U2 = 0.14 [W/(m2 K)]
Ψinstall = 0.06 W/(m K)
Exterior insulation and finishing system(EIFS) (fixed glazed)
U1 = 0.13 [W/(m2 K)]
Ψinstall = −0.00 W/(m K)
Exterior insulation and finishing system(EIFS) (operable)
U1 = 0.13 [W/(m2 K)]
Ψinstall = 0.03 W/(m K)
Exterior insulation and finishing system(EIFS) side (operable)
U1 = 0.13 [W/(m2 K)]
Ψinstall = 0.04 W/(m K)
4/5Component-ID: 0399sl03
www.passivehouse.com
www.passivehouse.com