PRIMERGY TX200 S4 Server Options Guide Edition December 2007

Upload: others

Post on 12-Mar-2020

17 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

PRIMERGY TX200 S4Server Options Guide

Edition December 2007

Page 2: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to [email protected].

Certified documentation according to DIN EN ISO 9001:2000To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2000.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and TrademarksCopyright © 2007 Fujitsu Siemens Computers GmbH.

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

Page 3: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1.1 Concept and target groups . . . . . . . . . . . . . . . . . . . 7

1.2 Overview of the documentation . . . . . . . . . . . . . . . . . 7

1.3 Extensions and conversions . . . . . . . . . . . . . . . . . . 9

1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . 11

2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

3 Safety notes . . . . . . . . . . . . . . . . . . . . . . . . . . 15

4 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

4.1 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . . 214.1.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 21

4.2 Rack model . . . . . . . . . . . . . . . . . . . . . . . . . . . 224.2.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 22

4.3 System fans and traverse . . . . . . . . . . . . . . . . . . . 244.3.1 Removing the system fan 1 . . . . . . . . . . . . . . . . . . . 244.3.2 Removing the system fan 2 . . . . . . . . . . . . . . . . . . . 254.3.3 Removing the traverse with the air duct over the main memory . 254.3.4 Removing the system fan 3 . . . . . . . . . . . . . . . . . . . 26

5 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 27

5.1 Equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . 27

5.2 Extending/replacing the main memory . . . . . . . . . . . . 28

Page 4: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

Options Guide TX200 S4

Contents

6 Processors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

6.1 Installing a second processor . . . . . . . . . . . . . . . . . 31

6.2 Replacing the processor . . . . . . . . . . . . . . . . . . . . 35

6.3 Replacing the heat sink . . . . . . . . . . . . . . . . . . . . . 37

7 Accessible drives and LSP . . . . . . . . . . . . . . . . . . . 39

7.1 Installing an accessible 5.25-inch drive . . . . . . . . . . . . 39

7.2 Installing the multibay . . . . . . . . . . . . . . . . . . . . . . 427.2.1 Installing a LSP in the multibay . . . . . . . . . . . . . . . . . . 46

7.3 Installing the hard disks extension box . . . . . . . . . . . . 48

8 Expansion boards in the PCI slots . . . . . . . . . . . . . . . 57

8.1 Installing an expansion board . . . . . . . . . . . . . . . . . 58

8.2 Installing a BBU . . . . . . . . . . . . . . . . . . . . . . . . . 61

8.3 Installing the Performance Adapter . . . . . . . . . . . . . . 64

9 SATA SW RAID . . . . . . . . . . . . . . . . . . . . . . . . . . 65

9.1 Inserting the RAID key . . . . . . . . . . . . . . . . . . . . . 65

10 Parallel interface for printers . . . . . . . . . . . . . . . . . . 67

10.1 Installing a parallel interface . . . . . . . . . . . . . . . . . . 67

11 Conversion to hot-plug PS and redundant system fans . . . 69

12 Converting from the floorstand model to the rack model . . 81

Page 5: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide

Contents

13 Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

13.1 System fans and traverse . . . . . . . . . . . . . . . . . . . 8513.1.1 Installing the system fan 3 . . . . . . . . . . . . . . . . . . . . 8513.1.2 Installing the traverse with the air duct over the main memory . 8613.1.3 Installing the system fan 2 . . . . . . . . . . . . . . . . . . . . 8613.1.4 Installing the system fan 1 . . . . . . . . . . . . . . . . . . . . 87

13.2 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . . 8813.2.1 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . 88

13.3 Rack model . . . . . . . . . . . . . . . . . . . . . . . . . . . 8913.3.1 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . 89

14 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

14.1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105

Page 6: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is
Page 7: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 7

1 IntroductionThe PRIMERGY TX200 S4 server is an Intel-based server for medium-sized and large networks. The server is suitable for use as a file server as well as an application, information, or Internet server. It is available as a floorstand or rack model. The floorstand model can be converted to a rack model using an optional conversion kit.

1.1 Concept and target groups

This Options Guide shows you how to extend and upgrade your server.

V CAUTION!

The activities described in this manual may only be performed by technical specialists.

I The installation and removal of the hot-plug components is described in the Operating Manual supplied with the server.

1.2 Overview of the documentation

The PRIMERGY TX200 S4 documentation comprises the following additional manuals:

– “Quick Start Hardware - PRIMERGY TX200 S4“ poster (only available as print supplied with the server)

– “Quick Start Software - Quick Installation Guide“ poster (only available as print supplied with the server

– “Safety notes and other important information” manual

– “Warranty” manual

– “Customer Self Service (CSS)” manual

– “Ergonomics” manual

– “Returning used devices” manual

– “Help desk” leaflet

– Technical Manual for the system board D2509

Page 8: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

8 Options Guide TX200 S4

Overview of the documentation Introduction

– Operating Manual for PRIMERGY TX200 S4

– Options Guide for PRIMERGY TX200 S4

– “BIOS-Setup V4.06 / FirstBIOS Desktop Pro V5.0 /TrustedCoreTM V6.0” manual

– “iRMCS2 - integrated Remote Management Controller” manual

– “LSI SATA Software RAID User’s Guide” manual

– “Integrated RAID for SAS User’s Guide” manual

– “SAS/SATA Controller MegaRAID 1064 / 1068 / 1078 Installation Guide” manual

I PRIMERGY manuals are available in PDF format on the ServerBooks DVD. The ServerBooks DVD is part of the ServerStart Suite supplied with every server.

The PDF files of the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found using the URL: http://manuals.fujitsu-siemens.com. The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option.

You can order a supplementary ServerBooks DVD by sending an e-mail to the following address, quoting your server data: [email protected]

Further sources of information:

– Technical Manual on the relevant rack– Manual on the monitor– Documentation on boards and drives– Documentation on your operating system– Information files on your operating system

Page 9: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 9

Introduction Extensions and conversions

1.3 Extensions and conversions

Second processor

The system board can be upgraded with a second processor. Only processors of the same type may be used on the system board. The second processor must have at least the same clock frequency as the first processor.

Extension of the main memory

Six slots (2 slots form a memory bank) are provided for the main memory. Each memory bank can be populated with two 512 Mbyte, 1Gbyte, 2Gbyte or 4Gbyte FDB667/PC2-5300F fully buffered DIMM memory modules.

Additional accessible drives

Three 5.25-inch bays are available for accessible drives. In these bays you can install DVD/DVD-RW drives, magnetic tape drives, a multibay (slimline DVD and FDD/ServerView Local Service Panel) or a hard disks extension box.

ServerView Local Service Panel

The system board supports the CSS (Customer Self Service) functionality (description see the operating manual). You can install a ServerView Local Service Panel for an easier identification of the defective components.

Hard disks extension box

Two 5.25-inch bays for accessible drives can be used to install a hard disks extension box.

Two variants of the hard disks extension box are available:

– Variant 1:one bay for a ServerView Local Service Panel, one bay for a slimline DVD drive and two bays for 3.5“ hard disks

– Variant 2:eight bays for 2.5“ hard disks

Page 10: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

10 Options Guide TX200 S4

Extensions and conversions Introduction

Additional expansion boards in the PCI slots

The system board offers seven PCI slots:

– 2 x PCI-X slots(64 bit / 133 MHz IOOPTM)– 4 x PCI-Express slots, Gen1, mechanical PCIe x8– 1 x PCI slot 32 bit / 33 MHz)

Performance Adapter SNR: S26361-D2504:The Performance Adapter combines two PCIe x4 slots to one PCIe x8 slot. If the adapter has been installed in slot 2 (or 7), slot 1 (or 6) can be operated as PCIe x8.

SATA Software RAID

The SATA SW RAID 5 functionality will be activated by installing a license key (RAID key).

Parallel interface for printers

As an option, a parallel interface can be provided for printers.

Conversion standard power supply to hot-plug power supply and standard system fans to redundant system fans

The standard power supply can be replaced by a hot-plug power supply. The hot-plug power supply consists of two power supply modules.

If one power supply module fails, the other power supply module guarantees the unrestricted operation and the defective power supply module can be replaced be replaced while the system is operating (hot-plug).

The standard system fans can be upgraded to redundant system fans. If the redundant system fans are installed, the fans are operating in a redundant configuration. A defective system fan can be replaced during the next service.

Conversion of the floorstand model to a rack model

The floorstand model can optionally be converted so that the server can be integrated into the common rack systems.

Page 11: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 11

Introduction Notational conventions

1.4 Notational conventions

The following notational conventions are used in this manual:

Text in italics indicates commands or menu items.

„Quotation marks“ indicate names of chapters and terms that are being emphasized.

Ê describes activities that must be performed in the order shown.

V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

Table 1: Notational conventions

Page 12: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is
Page 13: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 13

2 ProcedureV CAUTION!

The actions described in these instructions should only be performed by technical specialists. Equipment repairs should only be performed by authorized, qualified staff. Any unauthorized opening and improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment. Please note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability.

Ê First of all please familiarize yourself with the safety instructions in the section chapter “Safety notes” on page 15ff.

Ê Ensure that all required manuals are available, printing out the PDF files if necessary. You will definitely need the Operating Manual for the server and the Technical Manual for the system board.

Ê Shut down the server correctly, switch it off, pull out the power plug, and open the server as described in the chapter “Preparation” on page 21ff.

Ê Extend or upgrade your server as described in the relevant chapter.

I The Operating Manual for the server describes how you install/remove the hot-plug components.

I Procedures which are identical for the floorstand and rack models are only described for the floorstand model.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

Ê Start the operating system and, if necessary, configure it as required (see the Operating Manual).

Page 14: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is
Page 15: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 15

3 Safety notesI The following safety notes are also provided in the “Safety notes and

other important information” manual.

This device complies with the relevant safety regulations for data processing equipment. If you have any questions about where you can set up the device, contact your sales outlet or our customer service team.

V CAUTION!

● The actions described in this manual should only be performed by technical specialists.

● Repairs to the device that do not relate to CSS errors must only be carried out by service personnel. Please note that unauthorized inter-ference with the system will void the warranty and exempt the manufacturer from all liability.

● Any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment.

Before operating the device

V CAUTION!

● During installation and before operating the device, observe the instructions on environmental conditions for your device.

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the machine.

Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

● Transport the device only in the original packaging or in packaging that protects it from knocks and jolts.

Page 16: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

16 Options Guide TX200 S4

Safety notes

Installation and operation

V CAUTION!

● If the rack model is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type A connector.

● The server automatically sets itself to a voltage in the range of 100 V to 240 V. Make sure that your local voltage is within this range.

● This device has a specially approved power cable and must only be connected to a grounded insulated socket (floorstand model) respec-tively to a safety socket on the rack mains socket strip (rack model).

● Ensure that the power socket on the device or the grounded wall outlet is freely accessible.

● The ON/OFF button does not disconnect the device from the mains voltage. To disconnect the line voltage completely, remove the power plug from the power socket.

● Always connect the device and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still operating but the peripheral device (e.g. storage subsystem) has failed during a power outage.

● Take notice that the data cables to peripheral devices are adequately shielded.

● To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174-1/2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 MBps Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC 11801 are to be considered.

● When you set up the floorstand model with hot-plug power supply units, you should ensure that the supplied anti-tilt bracket is correctly fitted to prevent tilting.

● Route the cables in such a way that they do not form a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting up a device, refer to the relevant notes in this manual.

Page 17: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 17

Safety notes

V CAUTION!

● Never connect or disconnect data transmission lines during a storm (lightning hazard).

● Make sure that no objects (such as bracelets or paper clips) fall into or liquids spill into the device (risk of electric shock or short circuit).

● In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign matter), switch off the device immediately, remove the power plug and contact your sales outlet or customer service team.

● Proper operation of the device (in accordance with IEC 60950-1/EN 60950-1) is only ensured if the casing is completely assembled and the rear covers for the installation openings have been put in place (electric shock, cooling, fire protection, interference suppression).

● Install only system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment. If you install other expan-sions, you may damage the system or violate the safety regulations and regulations governing RFI suppression. Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet.

● The components or parts marked with a warning label (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. The hot-plug power supply units are exceptions to this rule.

● The warranty expires if the device is damaged during the installation or replacement of system expansions.

● You may only set those resolutions and refresh rates specified in the operating manual of the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service centre.

Page 18: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

18 Options Guide TX200 S4

Safety notes

Batteries

V CAUTION!

● Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board).

● Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board.

Working with CDs/DVDs and CD/DVD drives

When working with devices with CD/DVD drives, these instructions must be followed.

V CAUTION!

● Only use CDs/DVDs that are in perfect condition in your server's CD/DVD drive, in order to prevent data loss, equipment damage and injury.

● Check each CD/DVD for damage, cracks, breakages etc. before inserting it in the drive.

Note that any additional labels applied may change the mechanical properties of a CD/DVD and cause imbalance.

Damaged and imbalanced CDs/DVDs can break at high drive speeds (data loss).

Under certain circumstances, sharp CD/DVD fragments can pierce the cover of the CD/DVD drive (equipment damage) and can fly out of the device (danger of injury, particularly to uncovered body parts such as the face or neck).

I You can prevent mechanical damage and damage to the CD/DVD drive, as well as premature CD/DVD wear, by observing the following sugges-tions:

● Only insert CDs/DVDs in the drive when needed and remove them after use.

● Store the CDs/DVDs in suitable sleeves.

● Protect the CDs/DVDs from exposure to heat and direct sunlight.

Page 19: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 19

Safety notes

I Laser information

The CD/DVD drive complies with IEC 60825-1 laser class 1.

V CAUTION!

The CD/DVD drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous.

Never remove parts of the CD/DVD drive casing!

Modules with electrostatic-sensitive components:

Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label:

Figure 1: ESD label

When you handle components fitted with ESDs, you must observe the following points under all circumstances:

● Remove the power plug from the power socket before inserting or removing components containing ESDs.

● You must always discharge static build up (e.g. by touching a grounded object) before working.

● The equipment and tools you use must be free of static charge.

● Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components.

● Always hold components with ESDs at the edges or at the positions highlighted in green (touch points).

● Do not touch any exposed pins or conductors on a component.

Page 20: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

20 Options Guide TX200 S4

Safety notes

● Place all components on a static-safe base.

I You will find a detailed description for handling ESD components in the relevant European or international standards (DIN EN 61340-5-1, ANSI/ESD S20.20).

Page 21: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 21

4 PreparationV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15ff.

4.1 Floorstand model

4.1.1 Opening the server

Ê Terminate all applications and shut down the server correctly.

Ê If your operating system has not switched off the sever, press the on/off switch.

Ê Pull all power connectors out of the power outlets.

Figure 2: Opening the server

Ê Open the latch (1).

The opening of the latch pushes back the side cover (2) and disengages the hooks on the top of the side cover.

Ê Remove the side cover (3).

1

2

3

Page 22: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

22 Options Guide TX200 S4

Rack model Preparation

4.2 Rack model

Ê Terminate all applications and shut down the server correctly.

Ê If your operating system has not switched off the server, press the on/off button.

Ê Pull all power connectors out of the power outlets.

4.2.1 Opening the server

Pulling the server out of the rack and opening the server

Figure 3: Loosening the knurled screws

Ê Loosen the two knurled screws (1) and pull the server as far as possible out of the rack (2).

Ê Open the latch.

Ê Remove the top cover.

Removing the server from the rack and opening the server

Depending on how accessible the server is in the rack cabinet, it can make sense to remove the server from the rack cabinet:

Ê Disconnect all cables on the rear side of the server.

1

21

Page 23: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 23

Preparation Rack model

Figure 4: Loosening the screws in the rack cabinet

Ê Loosen the screws (1+2) on the left and the right side at the rear side.

V CAUTION!

At least two people are needed to lift the server out of the rack cabinet.

Ê Loosen the two knurled screws at the front side (see the figure 3 on page 22) and pull the server carefully out of the rack.

V CAUTION!

If you pull out the server too far, the server will fall down.

Ê Lift the server out of the rails and place it on a table, for example.

Ê Open the latch.

Ê Remove the top cover.

1

2

Page 24: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

24 Options Guide TX200 S4

System fans and traverse Preparation

4.3 System fans and traverse

4.3.1 Removing the system fan 1

Figure 5: Removing the system fan 1

Ê Disconnect the fan cable from the connector FAN1 SYS on the system board.

Ê Push the lock (1) in direction of the arrow until it disengages.

Ê Push the air duct to the front side (2) until the pins on the PSU casing and the traverse disengage.

Ê Remove the air duct with the integrated system fan 1.

2

1

Page 25: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 25

Preparation System fans and traverse

4.3.2 Removing the system fan 2

Figure 6: Removing the system fan 2

Ê Disconnect the fan cable from the connector FAN2 SYS on the system board.

Ê Pull the lock upward (1) and swivel the system fan 2 forward (2).

Ê Take out the system fan 2 downward.

4.3.3 Removing the traverse with the air duct over the main memory

Ê Remove the system fan 1 and system fan 2.

Figure 7: Removing the traverse

Ê Push the lock (1) and pull out the traverse sideward (2).

1

2

2

1

Page 26: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

26 Options Guide TX200 S4

System fans and traverse Preparation

Ê Unhook the traverse at the left side (see circles).

Ê Take the traverse with the memory air duct carefully out of the housing.

4.3.4 Removing the system fan 3

Ê Remove the system fan 1, system fan 2 and the traverse.

Figure 8: Removing the system fan 3

Ê Disconnect the fan cable from the connector FAN3 SYS on the system board.

Ê Pull the lock (1) inward.

Ê Pull the system fan 3 forward (2) to disengage the four snap-fits (see circles).

Ê Remove the system fan 3 sideward.

2

1

Page 27: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 27

5 Main memoryV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15ff.

The system board supports up to 24 Gbytes of main memory. 6 slots (2 slots form a memory bank) are provided for the main memory. Each memory bank is equipped with two 512 Mbyte, 1 Gbyte, 2 Gbyte or 4 Gbyte FBD667/PC2-5300F Fully Buffered DIMM memory modules.

As memory bank 1 is already equipped either with 1 Gbyte, 2 Gbyte, 4 Gbyte or8 Gbyte of memory in the basic unit, the memory extensions can be performed up to two times for memory banks 2 and 3.

ECC with memory scrubbing and with the Single Device Data Correction (SDDC, Chipkill) function is standard.

5.1 Equipping rules

Figure 9: Structure of the main memory in memory banks and memory modules

– The memory modules have to be based on x4 or x8 organised single or dual ranked FDB667/PC2-5300 fully buffered DIMM modules and must be populated in pairs. It is only allowed you use memory modules released by Fujitsu Siemens Computers.

– Each pair must consist of identical memory modules.

DIMM-3B

DIMM-2B

DIMM-1B

DIMM-3A

DIMM-2A

DIMM-1A

Page 28: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

28 Options Guide TX200 S4

Extending/replacing the main memory Main memory

– The module capacity between pairs can differ: pair 1A/1B can be populated with two 512 Mbyte modules and pair 2A/2B with two 1 Gbyte modules.

The table below shows the order in which the memory banks must be equipped:

5.2 Extending/replacing the main memory

Ê Open the server, remove the system fan 1, the system fan 2 and the traverse as described in the chapter “Preparation” on page 21ff.

Figure 10: Removing a memory module

Ê Press the holders on either side of the mounting location concerned outward (1).

Ê If the mounting location was already equipped: pull the memory module out of the mounting location (2).

module pair 1A/1B(black)

module pair 2A/2B(blue)

module pair 3A/3B(blue)

populated empty empty

populated populated empty

populated populated populated

1

12

Page 29: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 29

Main memory Extending/replacing the main memory

Figure 11: Inserting a memory module

Ê Press the holders on either side of the mounting location concerned outward.

Ê Insert the memory module in the mounting location (1) until the holders at the sides engage (2).

Ê Reinsert the traverse, the system fan 1 and system fan 2 as described in the chapter “Completion” on page 85ff.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

2

21

Page 30: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is
Page 31: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 31

6 ProcessorsV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15ff.

V CAUTION!

Processors are modules which can react extremely sensitively to electro-static discharges and which must therefore always be handled with care. After a processor has been removed from its protective sleeve or from its socket, place it with its smooth side down on a non-conducting, antistatic surface. Never push a processor over a surface.

6.1 Installing a second processor

The system board can be upgraded with a second processor. The upgrade kit consists of a processor and a heat sink.

V CAUTION!

Only processors of the same type may be used on the system board. The second processor must have at least the same clock frequency as the first processor. If the two processors have different clock frequencies, they both will operate with the lower clock frequency.

For dual operation, use a suitable multiprocessor operating system.

Ê Open the server, remove the system fan 1, the system fan 2 and the traverse as described in the chapter “Preparation” on page 21ff.

Page 32: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

32 Options Guide TX200 S4

Installing a second processor Processors

Installing the processor and the heat sink

Figure 12: Releasing the lever

Ê Release the socket lifter by pressing it sideways and pull it upward as far as it will go (1).

Ê Open the cover (2).

Figure 13: Inserting the processor

Ê Position the new processor over the socket and then carefully press it into the socket (1).

V CAUTION!

The processor can only be installed in one particular direction. Note the marking on one of the corners. To avoid damaging the processor, do not force it into the socket.

Ê Close the cover (2).

Ê Remove the plastic cover (3).

1

2

1

2

4

3

Page 33: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 33

Processors Installing a second processor

Ê Lock the processor in place in the socket by returning the socket lifter to its original position (4).

Figure 14: Removing the protective cover

Ê Remove the protective cover on the underside of the heat sink.

Page 34: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

34 Options Guide TX200 S4

Installing a second processor Processors

Figure 15: Installing the heat sink

Ê Place the heat sink on the processor socket.

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

V CAUTION!

Never install a processor without a heat sink and processor fan as otherwise the processor may overheat, causing the processor and system board to fail.

Ê Reinsert the traverse, the system fan 1 and system fan 2 as described in the chapter “Completion” on page 85ff.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

Page 35: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 35

Processors Replacing the processor

6.2 Replacing the processor

V CAUTION!

Only processors of the same type may be used on the system board. The second processor must have at least the same clock frequency as the first processor. If the two processors have different clock frequencies, they both will operate with the lower clock frequency.

For dual operation, use a suitable multiprocessor operating system.

Ê Open the server, remove the system fan 1, the system fan 2 and the traverse as described in the chapter “Preparation” on page 21ff.

Ê Loosen the four screws of the heat sink in a crossover pattern.

Ê Loosen the heat sink by turning it back and forth and then lift it out.

Ê Remove the residual thermal paste from the underside of the heat sink.

Ê Clean the underside of the heat sink using a lint-free cloth.

Figure 16: Removing an old processor

Ê Release the socket lifter by pressing it sideways and pull it upward as far as it will go (1).

Ê Open the cover (2).

Ê Lift the installed processor carefully out of the socket (3).

1

2

3

Page 36: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

36 Options Guide TX200 S4

Replacing the processor Processors

Figure 17: Inserting a new processor

Ê Position the new processor over the socket and thenplace it carefully into the socket (1).

V CAUTION!

The processor can only be installed in one particular direction. Note the marking on one of the corners. To avoid damaging the processor, do not force it into the socket.

Ê Close the cover (2).

Ê Lock the processor in place in the socket by returning the socket lifter to its original position (3).

Ê Apply a small amount of thermal paste to the upper side of the new processor.

Ê Ensure a thin and even distribution of the thermal paste.

Ê Place the heat sink on the processor socket (see page 34).

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

Ê Reinsert the traverse, the system fan 1 and system fan 2 as described in the chapter “Completion” on page 85ff.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

1

2

3

Page 37: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 37

Processors Replacing the heat sink

6.3 Replacing the heat sink

Ê Open the server, remove the system fan 1, the system fan 2 and the traverse as described in the chapter “Preparation” on page 21ff.

Ê Loosen the four screws of the heat sink socket in a crossover pattern.

Ê Loosen the heat sink by turning it back and forth and then lift it out.

Ê Clean the upper side of the processor using a lint-free cloth.

Ê Remove the protective cover from the new heat sink (see page 33).

Ê Place the heat sink on the processor socket (see page 34).

Ê Fasten the heat sink by tightening the four screws in a crossover pattern.

Ê Reinsert the traverse, the system fan 1 and system fan 2 as described in the chapter “Completion” on page 85ff.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

Page 38: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is
Page 39: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 39

7 Accessible drives and LSPV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15ff.

Three 5.25-inch bays are available for accessible drives. In these bays you can install DVD/DVD-RW drives, magnetic tape drives, a multibay (slimline DVD and FDD/ServerView Local Service Panel) or a hard disks extension box.

7.1 Installing an accessible 5.25-inch drive

The 5.25-inch drives available are magnetic tape drives and DVD-ROM burners. These drives can be installed in the free 5.25-inch bays.

Ê Open the server as described in the chapter “Preparation” on page 21ff.

I If you install a magnetic tape drive with double height (3.2-inch), two dummy modules of the free 5.25-inch bays must be removed.

Figure 18: Removing the screws of the dummy module

Ê Remove the two screws (see the circles).

Page 40: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

40 Options Guide TX200 S4

Installing an accessible 5.25-inch drive Accessible drives and LSP

Figure 19: Removing the dummy module

Ê Push the dummy module out of the bay frontward.

V CAUTION!

Keep the dummy module for future use. If you remove the accessible drive again and do not replace it with a new one, the dummy module must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Ê Push the new drive about halfway into the bay.

Ê Connect the data cable to the accessible drive (see the cabling plans in the Appendix).

Ê Connect the power cable to the accessible drive (see the cabling plans in the Appendix).

Ê Push the drive fully into the bay and fasten it with two screws.

Page 41: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 41

Accessible drives and LSP Installing an accessible 5.25-inch drive

Figure 20: Example cabling CD drive

Ê Connect the data cable to the system board (see the cabling plans in the Appendix).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

Page 42: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

42 Options Guide TX200 S4

Installing the multibay Accessible drives and LSP

7.2 Installing the multibay

Ê Open the server as described in the chapter “Preparation” on page 21ff.

Ê Remove the dummy module from a 5.25-inch bay for accessible drives:

Ê Remove the two screws.

Ê Push the dummy module out of the bay frontward.

V CAUTION!

Keep the dummy module for future use. If you remove the multibay again and do not replace it with new drives, the dummy module must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Figure 21: Pushing the floppy drive in the multibay

Ê Push the floppy drive in the multibay and fasten it with two screws on each side.

I You can install a LSP (ServerView Local Service Panel) instead of the floppy drive (see section “Installing a LSP in the multibay” on page 46).

Page 43: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 43

Accessible drives and LSP Installing the multibay

Figure 22: Removing the slimline dummy module

Ê Pull up the green touch point.

Ê Pull out the slimline dummy module frontward.

Figure 23: Removing the slimline frame

Ê Expand the frame sideward.

Page 44: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

44 Options Guide TX200 S4

Installing the multibay Accessible drives and LSP

Figure 24: Inserting the slimline drive in the frame

Ê Insert the slimline drive in the frame: the four noses fasten the drive to the frame.

Ê Push the slimline drive with its frame in the bay of the multibay until it engages.

Figure 25: Cabling of the slimline drive

Ê Connect the PS adapter cable to the slimline drive (see the cabling plans in the Appendix).

Ê Connect the SATA cable to the slimline drive (see the cabling plans in the Appendix).

Page 45: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 45

Accessible drives and LSP Installing the multibay

Figure 26: Installing the multibay

Ê Push the multibay with its cables in the lower bay until the holes fit to the threads.

Ê Fasten the multibay with two screws (see the circles).

Ê Connect the PS adapter cable of the slimline drive to a power plug (see the cabling plans in the Appendix).

Ê Connect a power plug to the floppy drive (see the cabling plans in the Appendix).

Ê Connect the floppy cable to the floppy drive and to the connector Floppy on the system board (see the cabling plans in the Appendix).

Ê Connect the SATA cable of the slimline drive to the system board (see the cabling plans in the Appendix).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

Page 46: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

46 Options Guide TX200 S4

Installing the multibay Accessible drives and LSP

7.2.1 Installing a LSP in the multibay

Figure 27: LSP frame

Figure 28: Inserting a LSP in the frame

Ê Push the LSP in the frame until it engages in the upper recess (see the circle).

Page 47: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 47

Accessible drives and LSP Installing the multibay

Figure 29: Inserting a LSP in the multibay

Ê Push the frame in multibay from the rear side and fasten the frame with two screws on each side.

Figure 30: Cabling the LSP

Ê After installing the multibay in the server: connect the free plug of the I2C cable to the LSP.

Page 48: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

48 Options Guide TX200 S4

Installing the hard disks extension box Accessible drives and LSP

7.3 Installing the hard disks extension box

Two 5.25-inch bays for accessible drives can be used to install a hard disks extension box.

Two variants of the hard disks extension box are available:

– Variant 1:one bay for a ServerView Local Service Panel, one bay for a slimline DVD drive and two bays for 3.5“ hard disks

– Variant 2 (special release required):eight bays for 2.5“ hard disks

Ê Open the server as described in the chapter “Preparation” on page 21ff.

Ê Remove the dummy modules from two 5.25-inch bays for accessible drives:

Ê Remove the two screws.

Ê Push the dummy module out of the bay frontward.

V CAUTION!

Keep the dummy modules for future use. If you remove the hard disks extension box again and do not replace it with new drives, the dummy modules must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Page 49: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 49

Accessible drives and LSP Installing the hard disks extension box

Removing and pushing inward of the metal brackets

The upper drives lay on four metal brackets. You have to remove and push inward the four metal brackets before it is possible to insert the hard disks extension box.

Figure 31: Removing the metal brackets - first step

Ê Break the two metal brackets out of the housing using a screws driver.

V CAUTION!

The sharp cant may hurt you!

Page 50: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

50 Options Guide TX200 S4

Installing the hard disks extension box Accessible drives and LSP

Figure 32: Removing the metal brackets - second step

Figure 33: Removing the metal brackets - third step

Ê Turn the two metal brackets around until they break out.

Page 51: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 51

Accessible drives and LSP Installing the hard disks extension box

Figure 34: Pushing inward the metal brackets - first step

Ê Break through the pointy sides of the two inner metal brackets using a screws driver.

Figure 35: Pushing inward the metal brackets - second step

Ê Push the metal brackets inward until they cannot blockade the interior space of the bay.

Page 52: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

52 Options Guide TX200 S4

Installing the hard disks extension box Accessible drives and LSP

3.5“ hard disks extension box

Ê Remove and push the metal brackets inward before.

Figure 36: Installing 3.5“ hard disks extension box

Ê Push the hard disks extension box fully into the bay and fasten it with four screws.

Figure 37: Example connecting the power cable

Ê Connect the power cable to the hard disks extension box (see the cabling plans in the Appendix).

Page 53: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 53

Accessible drives and LSP Installing the hard disks extension box

Figure 38: Example connecting the SATA cable

Ê Connect the SATA cable to the hard disks extension box and the second port of a controller (see the cabling plans in the Appendix).

I It is possible to install a slimline drive in the hard disks extension box. The procedure is the same as for installing the slimline drive in the multibay.

I It is possible to install a LSP in the hard disks extension box. In this case you can push the LSP in the top bay of the hard disks extension box without using a frame.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

Page 54: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

54 Options Guide TX200 S4

Installing the hard disks extension box Accessible drives and LSP

2.5“ hard disks extension box

Ê Push the metal brackets inward until they cannot blockade the interior space of the bay.

Figure 39: Installing 2.5“ hard disks extension box

Ê Push the hard disks extension box fully into the bay and fasten it with three screws.

Figure 40: Example connecting the SATA cables to the controller

Ê Connect the SATA cable to the hard disks extension box and the second port of a controller (see the cabling plans in the Appendix).

Page 55: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 55

Accessible drives and LSP Installing the hard disks extension box

Figure 41: Example connecting the PS and SAS cables

Ê Connect the power cables and the SAS cables to the hard disks extension box (see the cabling plans in the Appendix).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

Page 56: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is
Page 57: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 57

8 Expansion boards in the PCI slotsV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15ff.

The system board offers seven PCI slots:

– 2 x PCI-X slots(64 bit / 133 MHz IOOPTM)– 4 x PCI-Express slots, Gen1, mechanical PCIe x8– 1 x PCI slot 32 bit / 33 MHz)

The hardware of the system board optimizes the speed of the PCI bus (IOOP™) for PCI slots 4 and 5, depending on how the slots are equipped. If only one of this two slots is occupied, the PCI bus speed is 133 MHz. If both slots are occupied, the PCI bus speed is 100 MHz.

Performance Adapter SNR: S26361-D2504:The Performance Adapter combines two PCIe x4 slots to one PCIe x8 slot. If the adapter has been installed in slot 2 (or 7), slot 1 (or 6) can be operated as PCIe x8.

Page 58: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

58 Options Guide TX200 S4

Installing an expansion board Expansion boards in the PCI slots

8.1 Installing an expansion board

Ê Open the server as described in the chapter “Preparation” on page 21ff.

Ê Remove the system fan 2 as described in the section “Removing the system fan 2” on page 25.

Figure 42: Loosening the locking levers

Ê Press on the two green locking levers in the direction of the arrow and push the locking levers out of the housing.

Page 59: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 59

Expansion boards in the PCI slots Installing an expansion board

Figure 43: Opening the slot locking bar

Ê Open the slot locking bar.

Page 60: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

60 Options Guide TX200 S4

Installing an expansion board Expansion boards in the PCI slots

Figure 44: Removing the slot cover

Ê Remove the PCI slot cover.

V CAUTION!

Keep the slot cover for further use. If the expansion board is removed again and not replaced with a new one, the slot cover has to be reinstalled to comply with applicable EMC regulations and satisfy cooling requirements and fire protection measures.

Ê Unpack the new expansion board, and make the desired settings. You should read the accompanying documentation supplied with the expansion board beforehand.

Ê Install the expansion board into the PCI slot and press it carefully into the associated plug-in location on the system board until it engages properly.

Ê Close the slot locking bar and press on the two green locking levers at the server’s rear side until they engage.

Ê If required, connect the cables to the expansion board and other compo-nents.

Page 61: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 61

Expansion boards in the PCI slots Installing a BBU

Ê Install the system fan 2 as described in the section “Installing the system fan 2” on page 86.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

8.2 Installing a BBU

You can install up to two Battery Backup Units (BBU).

Ê Open the server as described in the chapter “Preparation” on page 21ff.

Ê Remove the system fan 1, the system fan 2 and the traverse as described in the section “System fans and traverse” on page 24ff.

Figure 45: Connecting the cable to the BBU

Ê Connect the cable to the BBU and the expansion board.

V CAUTION!

Make sure that the connector side with two pin rows is on the top. Otherwise you risk short-circuits.

Page 62: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

62 Options Guide TX200 S4

Installing a BBU Expansion boards in the PCI slots

Ê Install the expansion board.

Figure 46: Inserting the BBU

Ê Push the BBU in the housing.

Side with one pin row: Side with two pin rows:

Page 63: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 63

Expansion boards in the PCI slots Installing a BBU

Figure 47: Position screws

Ê Fasten the BBU with three screws at the outer side (the first BBU in the front range, a second BBU in the middle range).

Ê Install the traverse, the system fan 2 and the system fan 1 as described in the section “System fans and traverse” on page 85ff.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

BBU 1BBU 2

Page 64: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

64 Options Guide TX200 S4

Installing the Performance Adapter Expansion boards in the PCI slots

8.3 Installing the Performance Adapter

Ê Open the server as described in the chapter “Preparation” on page 21ff.

Ê Remove the system fan 1and the system fan 2 as described in the section “System fans and traverse” on page 24ff.

Figure 48: Performance Adapter in slot 7

Ê Insert the Performance Adapter in slot 2 or slot 7.

Ê Install the system fan 2 and the system fan 1 as described in the section “System fans and traverse” on page 85ff.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

Page 65: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 65

9 SATA SW RAIDV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15ff.

The SATA SW RAID 5 functionality will be activated by installing a license key (RAID key).

9.1 Inserting the RAID key

Ê Open the server as described in the chapter “Preparation” on page 21ff.

Ê Remove the system fan 2 as described in the section “Removing the system fan 2” on page 25.

Figure 49: Inserting the RAID key

Ê Insert the RAID key in the round socket on the system board.

Ê Install the system fan 2 as described in the section “Installing the system fan 2” on page 86.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

Page 66: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is
Page 67: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 67

10 Parallel interface for printersV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15ff.

10.1 Installing a parallel interface

Ê Open the server as described in the chapter “Preparation” on page 21ff.

Ê Remove the system fan 1, the system fan 2 and the traverse as described in the section “System fans and traverse” on page 24ff.

Ê Install the parallel interface as described in the section “Installing an expansion board” on page 58ff.

Figure 50: Routing the cable

Ê Route the cable as shown in the photo.

Ê Connect the cable’s connector to the parallel port connector on the system board.

Page 68: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

68 Options Guide TX200 S4

Installing a parallel interface Parallel interface for printers

Ê Install the traverse, the system fan 2 and the system fan 1 as described in the section “System fans and traverse” on page 85ff.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

Page 69: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 69

11 Conversion to hot-plug PS and redundant system fans

V CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15ff.

Ê Open the server as described in the chapter “Preparation” on page 21ff.

Ê Remove the system fan 1, the system fan 2 and the traverse as described in the section “System fans and traverse” on page 24ff.

Figure 51: Removing the power cables

Ê Disconnect all power cables from the system board and the drives (see the cabling plans in the Appendix).

Ê Thread the power cables through the openings.

Page 70: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

70 Options Guide TX200 S4

Conversion to hot-plug PS/redundant system fans

Figure 52: Removing the PSU

Ê Remove the four screws and pull the power supply unit inward and take it out of the server.

Figure 53: Removing the adapter metal cover

Ê Remove the six screws and push the adapter metal cover inward in a slight angle and take it out of the server.

Page 71: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 71

Conversion to hot-plug PS/redundant system fans

Figure 54: Installing the Power backplane in the PS cage

Ê Insert the Power backplane in the PS cage.

Ê Push the Power backplane in direction of the arrow until it engages in the guidances of the PS cage.

Ê Fasten the Power backplane with one screw (see circle).

Page 72: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

72 Options Guide TX200 S4

Conversion to hot-plug PS/redundant system fans

Figure 55: Breaking out the pre-cut plate

Ê Break out the pre-cut plate for the plug of the redundant fan using a screws driver.

Figure 56: Inserting the redundant fan

Ê Insert the redundant fan with its holder in the four recesses at the rear side of the housing.

Page 73: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 73

Conversion to hot-plug PS/redundant system fans

Figure 57: Fastening the holder

Ê Push the holder to the left side until the four hooks engage.

Ê Fasten the holder with three screws.

Page 74: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

74 Options Guide TX200 S4

Conversion to hot-plug PS/redundant system fans

Figure 58: Installing the PS cage

Ê Push the PS cage from the rear side into the housing. In the floorstand model the Power backplane is positioned under the top cover, and in the rack model at the right-hand side cover (seen from front side).

V CAUTION!

Make sure that the noses of the PS cage engage in the housing (see circles).

Page 75: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 75

Conversion to hot-plug PS/redundant system fans

Figure 59: Fastening the PS cage

Ê Fasten the PS cage with three screws.

Figure 60: Cabling of the redundant fan

Ê Connect the cable T26139-Y3908-V101 to the system board connector Fan4 SYS and to the fan connector (see the cabling plans in the Appendix).

Page 76: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

76 Options Guide TX200 S4

Conversion to hot-plug PS/redundant system fans

Figure 61: PS cabling - step 1

Ê Thread the power cable T26139-Y3758-V5 through the recess.

Ê Connect the power cable to the connector X3 on the Power backplane.

Ê Connect the power cable to the connector PWR1 on the system board.

Page 77: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 77

Conversion to hot-plug PS/redundant system fans

Figure 62: PS cabling - step 2

Ê Thread the power cable T26139-Y3952-V2 through the recess.

Ê Connect the power cable to the connector X4 on the Power backplane.

Ê Connect the power cable to the connectors PWR3, PWR2 and PC98 on the system board.

Page 78: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

78 Options Guide TX200 S4

Conversion to hot-plug PS/redundant system fans

Figure 63: PS cabling - step 3

Ê Thread the power cable T26139-Y3952-V101 through the recess.

Ê Connect the power cable to the connector X5 on the Power backplane.

Ê Connect the plugs of the power cable to the drives and the HDD backplanes (see the cabling plans in the Appendix).

Page 79: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 79

Conversion to hot-plug PS/redundant system fans

Figure 64: Installing the PS safe guard

Ê Install the PS safe guard and fasten it with one screw.

Ê Push the both power supply modules in the bays of PS cage until they engage (description see the operating manual).

Ê Install the traverse, the system fan 2 and the system fan 1 as described in the section “System fans and traverse” on page 85ff.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 85ff.

Page 80: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is
Page 81: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 81

12 Converting from the floorstand model to the rack model

V CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15ff.

Figure 65: Removing the stabilizer

Ê Remove the two screws.

Ê Lift the server somewhat and remove the stabilizer.

I The stabilizer is no longer required.

Ê Open the server as described in the chapter “Preparation” on page 21ff.

Page 82: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

82 Options Guide TX200 S4

Converting from the floorstand model to the rack model

Figure 66: Removing the front cover

Ê Release the three locks and open the front cover.

Ê Unhook the front cover at the other side and remove the front cover.

I The front cover is no longer required.

Ê Lay the server on its right-hand side. Get a second person to help you do this. The server can weigh up to 35 kg.

Page 83: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 83

Converting from the floorstand model to the rack model

Figure 67: Position of the recesses

Ê Press the three hooks of the plastic front cover on the bottom side in the recesses (see the circles) of the housing.

Ê Press the plastic front cover onto the housing until the three tabs on the top side (see the circles) engage.

Figure 68: Installed plastic front cover

Ê Close the server as described in the chapter “Completion” on page 85ff.

Page 84: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

84 Options Guide TX200 S4

Converting from the floorstand model to the rack model

Ê Install the rack model in the rack as described in the operating manual.

To enable the rack model to be presented correctly in ServerView, proceed as follows:

Ê Place the ServerStart CD-ROM CD1 in the drive.

Ê Select “Tools - System Configuration Utilities - SCU Chassis Model Conversion“ and convert the server type to rack mounted.

Page 85: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 85

13 CompletionV CAUTION!

Observe the safety instructions in the chapter “Safety notes” on page 15ff.

13.1 System fans and traverse

13.1.1 Installing the system fan 3

Figure 69: Installing the system fan 3

Ê Put the hooks of the system fan 3 into the recesses on the server’s rear side (see circles).

Ê Push the system fan 3 in direction to the connector panel until the lock engages.

Ê Connect the fan cable to the connector FAN3 SYS on the system board.

Page 86: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

86 Options Guide TX200 S4

System fans and traverse Completion

13.1.2 Installing the traverse with the air duct over the main memory

Ê Install the system fan 3 before.

Figure 70: Installing the traverse

Ê Insert carefully the traverse with the air duct over the main memory.

Ê Hook the traverse into the left side (see circles).

Ê Press on the traverse at the right side (see arrow) until the lock engages.

13.1.3 Installing the system fan 2

Ê Install the system fan 3 and the traverse before.

Figure 71: Installing the system fan 2

Ê Hook the system fan into the traverse (see circles) and press it in the housing until it clicks into place.

1

2

Page 87: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 87

Completion System fans and traverse

Ê Connect the fan cable to the connector FAN2 SYS on the system board.

13.1.4 Installing the system fan 1

Ê Install the system fan 3, the traverse and the system fan 2 before.

Figure 72: Installing the system fan 1

Ê Connect the fan cable to the connector FAN1 SYS on the system board.

Ê Insert carefully the air duct with the integrated system fan 1 using the pins on the PSU casing and the traverse (see circles).

Ê Push the air duct to the rear side until the pins on the PSU casing and the traverse engage. Make sure that the lock engages too.

Page 88: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

88 Options Guide TX200 S4

Floorstand model Completion

13.2 Floorstand model

13.2.1 Closing the server

Ê Open the latch.

Figure 73: Attaching the left-hand side cover

Ê Position the left-hand side cover in the five recesses (see circles) of the housing (1).

Ê Push the left-hand side cover against the housing and push down the latch (2).Closing the latch pushes the left-hand side cover to the front side and the hooks on the upper cant of the left-hand side cover engage.

Ê Insert the key.

Ê Lock the server.

Ê Connect all power plugs to the power outlets.

Ê Press the on/off key to start up the server.

2

1

Page 89: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 89

Completion Rack model

13.3 Rack model

13.3.1 Closing the server

Ê Open the latch.

Ê Position the top cover in the five recesses of the housing.

Ê Push the top cover against the housing and push down the latch.Closing the latch pushes the top cover to the front side and the hooks on the right-hand side cant of the top cover engage.

If you have not removed the server from the rack cabinet, please skip this step:

V CAUTION!

At least two people are required to install the server in the rack cabinet.

Do not use the handles on the rack front cover to lift the server into the rack.

Ê Lower the server from above onto the rails.

Figure 74: Installing the server in a rack cabinet

Ê Push the server as far as it will go into the rack (1).

Ê Fasten the server in the rack using the two knurled screws (2).

1

2

1

2

Page 90: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

90 Options Guide TX200 S4

Rack model Completion

If you have not removed the server from the rack cabinet, please skip this step:

Figure 75: Fastening the server in the rack cabinet at the rear side

Ê Fasten the rack unit at the rear side with two screws (1+2) on the left and the right side.

Ê Connect all power plugs to the power outlets.

Ê Press the on/off key to start up the server.

1

2

Page 91: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 91

14 Appendix

14.1 Cabling

You will find suggestions for cabling on the next pages.

Page 92: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

92 Options Guide TX200 S4

Cabling Appendix

Figure 76: Red. PS, 3.5“ HD, USB, SATA, slimline drive

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

Y3

96

3-V

10

3A

3C

40

08

91

97

FAN 4 SYSFAN 3 SYS

Y3925-V301 / A3C40087205

Y3973-V2 / A3C40073691

Page 93: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 93

Appendix Cabling

Figure 77: Red. PS, 2.5“ HD, 2.5“ HDD box, SATA

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

FA

N2

SY

S

5

2.5

“S

AS

HD

D4

2.5

“S

AS

HD

D5

2.5

“S

AS

HD

D6

2.5

“S

AS

HD

D7

X1

X6

X1

X6

Y2

19

3-V

11

1P

2

P4

Y2

19

3-V

11

1

P7

P6

P8

Y3963-V103 / A3C40089197

Y3963-V103

Y3963-V102

SA

TA

DV

D-R

om

X1

Fo

rm

odula

rR

AID

use

Y3

96

9-V

20

1

Fro

nt

vie

wH

DD

0-3

left

Fro

nt

vie

w(f

loo

rsta

nd)

HD

D0

-3 le

ft

Fro

nt

vie

wH

DD

4-7

rig

ht

Fro

nt

vie

w H

DD

4-7

ri

gh

t

Y3969-V201 / A3C40091986

A3C40086493 A3C40086493A3C40086493

Y3963-V102 / A3C40087289Y3952-V2 / A3C40087920

Page 94: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

94 Options Guide TX200 S4

Cabling Appendix

Figure 78: Standard PS, 3.5“ HD, USB, SATA, slimline drive

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

Y3

96

3-V

10

3A

3C

40

08

91

97

Y3973-V2 / A3C40073691

Page 95: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 95

Appendix Cabling

Figure 79: Standard PS, 3.5“ HD, SATA

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

Y3

96

3-V

10

3A

3C

40

08

91

97

P6

P1

8

P1

6P

15

P1

7P

7P

8P

9P

12

Page 96: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

96 Options Guide TX200 S4

Cabling Appendix

Figure 80: Standard PS, 2.5“ HD, 2.5“ HDD box, SATA

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

FA

N2

SY

S5

Fro

nt

vie

w H

DD

4-7

ri

gh

t

P1

4

Y2

19

3-

V1

11

P1

9

P2

Y2

19

3-

V1

11

P1

8

P1

6P

15

P1

7

P3

Y2

19

3-

V1

11

Y2

19

3-

V1

11

P6

P7

P8

P9

P1

2

P5

P4

Page 97: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 97

Appendix Cabling

Figure 81: Standard PS, 3.5“ HD, SCSI, SATA, LSP

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

Y3

98

0-V

11

/ A

3C

40

08

076

5

SA

TA

/ D

VD

0.5

Frontpanel

Y3925-V301 / A3C40087205

LS

P (

CS

S m

od

ule

) /

optio

na

l

Page 98: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

98 Options Guide TX200 S4

Cabling Appendix

Figure 82: Standard PS, 3.5“ HD, 3.5“ HDD box, slimline drive, LSP, BBU

Leg

en

d: P

ow

er

SA

TA

/S

AS

/U

SB

FD

Data

Y3

96

3-V

10

3/

A3

C4

00

891

97

BBU

A3C40080521

BB

U

Y3

99

0-V

1

Y3969-V201 / A3C40091986

P6

P7

P8

P9

X1

X5

P4

P5

Y3

96

3-V

20

2/

A

3C

40

089

270

X1

Y3925-V301 / A3C40087205

Frontpanel

Y3

98

7-V

2/

A3

C4

00

90

454

Intr

.

Page 99: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 99

AbbreviationsAC

Alternating Current

ANSIAmerican National Standard Institute

ASR&RAutomatic Server Reconfiguration and Restart

BIOSBasic Input-Output System

BMCBaseboard Management Controller

CCCache Coherency

CDCompact Disk

CD-ROMCompact Disk-Read Only Memory

CHSCylinder Head Sector

CMOSComplementary Metal Oxide Semiconductor

COMCommunication

CPUCentral Processing Unit

DCDirect Current

Page 100: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

100 Options Guide TX200 S4

Abbreviations

DIMMDual Inline Memory Module

DIPDual Inline Package

DMADirect Memory Access

DMIDesktop Management Interface

ECCError Checking and Correcting

ECPExtended Capabilities Port

EEPROMElectrically Erasable Programmable Read-Only Memory

EMCElectroMagnetic Compatibility)

EMPEmergency Management Port

EPPEnhanced Parallel Port

ESDElectroStatic Discharge

FPCFront Panel Controller

FRUField Replaceable Unit

FSBFront Side Bus

Page 101: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 101

Abbreviations

GAMGlobal Array Manager

GUIGraphical User Interface

HDDHard Disk Drive

HSCHot-Swap Controller

I²CInter-Integrated Circuit

I/OInput/Output

ICMIntelligent Chassis Management

IDIdentification

IDEIntegrated Drive Electronics

IOOPIntelligent Organization of PCI

iRMCintegrated Remote Management Controller

IRQInterrupt Request Line

LANLocal Area Network

LBALogical Block Address

Page 102: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

102 Options Guide TX200 S4

Abbreviations

LCDLiquid Crystal Display

LUNLogical Unit Number

LVDLow-Voltage Differential SCSI

MMFMulti Mode Faser

MRLManually Retention Latch

NMINon Maskable Interrupt

NVRAMNon Volatile Random Access Memory

OSOperating System

PCIPeripheral Component Interconnect

PDAPrefailure Detection and Analysing

POSTPower ON Self Test

RAIDRedundant Arrays of Independent Disks

RAMRandom Access Memory

ROMRead-Only Memory

Page 103: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 103

Abbreviations

RSBRemote Service Board

RTCReal Time Clock

RTDSRemote Test- und Diagnose-System

SAF-TESCSI Accessed Fault-Tolerance Enclosures

SASSerial Attached SCSI

SATASerial ATA

SBESingle Bit Error

SCASingle Connector Attachment

SCSISmall Computer System Interface

SDDCSingle Device Data Correction

SDRSensor Data Record

SDRAMSynchronous Dynamic Random Access Memory

SELSystem Event Log

SMISystem Management Interrupt

Page 104: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

104 Options Guide TX200 S4

Abbreviations

SSUSystem Setup Utility

SVGASuper Video Graphics Adapter

USBUniversal Serial Bus

VGAVideo Graphics Adapter

Page 105: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

TX200 S4 Options Guide 105

IndexAaccessible drives 9, 39

BBBU 61

Cconversion of floorstand model to rack

model 10conversion standard power supply to

hot-plug power supply 10, 69

Ddual operation 31, 35

EESD (devices sensitive to electrostatic

discharge) 19expansion board 10, 58

Ffloorstand to rack model

conversion 81

Hhard disks extension box 9heat sink 37

Iinformation material 8

Llaser information 19light emitting diode (LED) 19lithium battery 18

Mmain memory 9, 27meaning

of the symbols 11multiprocessor operating system 31,

35

Nnotational conventions 11

Pparallel interface 10, 67Performance Adapter 10, 64processor 9, 31

RRAID key 65

SServerView Local Service Panel 9,

46

Ttarget group 7

Uupgrade standard system fan to

redundant system fans 10, 69

Page 106: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is
Page 107: PRIMERGY TX200 S4 Server - Fujitsumanuals.ts.fujitsu.com/illustrated_spares/content/TX200_S4/pdf/og.pdf · TX200 S4 Options Guide 7 1 Introduction The PRIMERGY TX200 S4 server is

Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu-ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So-lutions.

This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.

Contact and support addresses will now be offered by Fujitsu Technology So-lutions and have the format …@ts.fujitsu.com.

The Internet pages of Fujitsu Technology Solutions are available at http://ts.fujitsu.com/... and the user documentation at http://manuals.ts.fujitsu.com.

Copyright Fujitsu Technology Solutions, 2009

Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit-dem den Namen Fujitsu Technology Solutions.

Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.

Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.

Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.

Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die Benutzerdokumentation.

Copyright Fujitsu Technology Solutions, 2009