primergy 10gbe connection blade 18/8 user guide...

96
User Guide PRIMERGY BX900 Blade Server Systems PRIMERGY 10GbE Connection Blade 18/8 Rev 6.1 English

Upload: phamkhanh

Post on 07-Mar-2018

241 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

User Guide

PRIMERGY BX900 Blade Server Systems PRIMERGY 10GbE Connection Blade 18/8

Rev 6.1 English

Page 2: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

1 / 95

PRIMERGY 10GbE Connection Blade 18/8

User Guide

Rev6.1

January 29, 2013

Page 3: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

2 / 95

Version History

Issue number Reason for update

6.1 / January 2013 Notes for restrictions added

Page 4: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

3 / 95

Table of Contents 1. Product Overview ............................................................................................................. 5

1.1 Description of Hardware ............................................................................................ 5 1.1.1 Front Panel Description ................................................................................... 5 1.1.2 SFP+ based ports ............................................................................................... 6 1.1.3 LEDs (B, C, D, E) ................................................................................................. 6 1.1.4 Reset Switch (F) ................................................................................................. 7 1.1.5 Hardware Specifications .................................................................................. 7

1.2 Description of Software .............................................................................................. 8 1.3 Restrictions and Hints ................................................................................................. 9

2. Getting Started ................................................................................................................ 10 2.1 Installing Connection Blade in PRIMERGY BX900/BX400 Blade Chassis ................................................................................................................ 10 2.2 Installing SFP+ Module in Connection Blade ................................................... 10 2.3 Setting up serial console connection .................................................................. 11 2.4 Configuring Connection Blade with connection blade CLI .......................... 12 2.5 Command Mode ........................................................................................................... 13 2.6 Changing Switch Mode ,IBP Mode and EHM ..................................................... 15 2.7 Checking version and system information ........................................................ 16

2.7.1 Checking version and firmware information ......................................... 16 2.7.2 Checking System information ..................................................................... 17

2.8 Configuration files ...................................................................................................... 18 2.8.1 Changing startup configuration file .......................................................... 18 2.8.2 Checking configuration file .......................................................................... 18 2.8.3 Saving configuration ....................................................................................... 18 2.8.4 Backup/Restore configuration .................................................................... 19 2.8.5 Clearing Configuration ................................................................................... 20

2.9 Updating Firmware ..................................................................................................... 20 2.10 Initializing Connection Blade with Backup Firm ......................................... 21 2.11 Recovery Firmware with Backup Firm ............................................................ 21

3. Configuring Switch Software ..................................................................................... 22 3.1 Configuring VLAN ........................................................................................................ 22

3.1.1 Configuring untag VLAN ................................................................................ 22 3.1.2 Configuring tag VLAN ..................................................................................... 22 3.1.3 Configuring protocol VLAN ........................................................................... 23

3.2 Configuring Link Aggregation ................................................................................ 24 3.2.1 Configuring Static Link Aggregation ......................................................... 24 3.2.2 Configuring Link Aggregation with LACP ................................................ 25

3.3 Configuring Backup Port .......................................................................................... 26 3.4 Configuring MAC filtering ........................................................................................ 27

3.4.1 Configuring MAC filter 1 ................................................................................ 28 3.4.2 Configuring MAC filter 2 ................................................................................ 29 3.4.3 Configuring MAC filter 3 ................................................................................ 29 3.4.4 Configuring MAC filter 4 ................................................................................ 30 3.4.5 Configuring MAC filter 5 ................................................................................ 31

3.5 Configuring Static MAC forwarding ...................................................................... 32 3.6 Configuring QoS .......................................................................................................... 33

3.6.1 Configuring priority control ......................................................................... 33 3.6.2 Configuring priority control rewrite .......................................................... 34

3.7 Configuring Spanning Tree ..................................................................................... 36 3.7.1 Configuring STP ................................................................................................ 36 3.7.2 Configuring MSTP ............................................................................................. 37

Page 5: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

4 / 95

3.8 Configuring IGMP Snooping .................................................................................... 41 3.9 Configuring IEEE802.1X Authentication ............................................................ 43 3.10 Configuring MAC Authentication ....................................................................... 46 3.11 Configuring Port Mirroring ................................................................................... 49 3.12 Configuring IP Filtering ........................................................................................ 50

3.12.1 Configuring IP filter ........................................................................................ 50 3.13 Configuring SNMP Agent ...................................................................................... 51 3.14 Configuring System Log ........................................................................................ 53 3.15 Configuring Link DownRelay ............................................................................... 54

4. Default Settings .............................................................................................................. 55 4.1 Switch Mode .................................................................................................................. 55 4.2 IBP Mode ........................................................................................................................ 56 4.3 EHM .................................................................................................................................. 57

5. Maximum Values ............................................................................................................. 59 5.1 Switch Mode .................................................................................................................. 59 5.2 IBP Mode ........................................................................................................................ 61 5.3 EHM .................................................................................................................................. 63

6. MIB/Trap List ................................................................................................................... 65 6.1 Standard MIB................................................................................................................ 65

6.1.1 System Group .................................................................................................... 65 6.1.2 Interface Group ................................................................................................ 65 6.1.3 Address Translation Group ........................................................................... 66 6.1.4 IP Group .............................................................................................................. 66 6.1.5 IGMP Group ........................................................................................................ 71 6.1.6 TCP Group ........................................................................................................... 73 6.1.7 UDP Group .......................................................................................................... 74 6.1.8 Dot3 Group ......................................................................................................... 75 6.1.9 SNMP Group ....................................................................................................... 76 6.1.10 rmon Group ........................................................................................................ 76 6.1.11 Dot1dBridge Group .......................................................................................... 79 6.1.12 qBridgeMIB Group ........................................................................................... 81 6.1.13 ifMIB Group ........................................................................................................ 82 6.1.14 radiusMIB Group .............................................................................................. 83 6.1.15 entityMIB Group ............................................................................................... 84

6.2 Fujitsu Private MIB .................................................................................................... 85 6.3 IEEE802.1MIB .............................................................................................................. 85 6.4 Trap List ......................................................................................................................... 95

Page 6: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

5 / 95

1. Product Overview The PRIMERGY 10GbE Connection Blade 18/8 is an integrated 10Gbit Ethernet switch for PRIMERGY

BX900/BX400 Blade Server System. This product has the Switch Mode provides Ethernet switching function as well as the Intelligent Blade Panel (IBP) Mode and EHM provide a simple Ethernet interface option for connecting the PRIMERGY

BX900/BX400 Blade Server Systems to the external network. The PRIMERGY 10GbE Connection Blade 18/8 provides the following hardware configuration - 18 internal 10GBASE-KR ports connected to servers through chassis backplane (18 downlink ports)

- 8 external Small Form-Factor Pluggable Plus (SFP+) based ports (8 uplink ports) - 1 internal console port connected to management blades through chassis backplane - 1 10/100 BASE-T port connected to management blades through chassis backplane

Figure1. PRIMERGY 10GbE Connection Blade 18/8

1.1 Description of Hardware This section shows front panel description and overview of the hardware specifications.

1.1.1 Front Panel Description Figure2 shows 8 SFP+ based ports, LED and Reset Switch in the Front Panel.

Figure2. PRIMERGY 10GbE Connection Blade 18/8 Front Panel

Front Panel Items

SFP+ Based Ports A SFP+ Based Ports

B ID LED

C Stack LED

D Status LED

E Port LED

F Reset Swith

A

B

C D

F E E

Page 7: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

6 / 95

1.1.2 SFP+ based ports

The PRIMERGY 10GbE Connection Blade 18/8 has 8 SFP+ based ports in front panel the port number is

assigned from 19 to 26. (The downlink port numbers are assigned from 1 to 18 corresponding with

server blade slots number)

Please refer to Data Sheet for modules and cables supported.

1.1.3 LEDs (B, C, D, E)

The PRIMERGY 10GbE Connection Blade 18/8 has 5 kinds of LED indicating Connection Blade status, port

status and activity and stacking status.

Table2. LEDs in front panel

LED Color Meaning

B ID Solid Blue Identified by MMB

Off Not identified by MMB

C Stack LED Not Used

D Status LED Solid Green Normal

Blinking Alternately Green/Amber

Connection Blade Failure

Off Power off

E Port LED

ERR

(LEFT)

Solid Amber SFP+ module error

Blinking Amber SFP+ module not supported

Off No SFP+ module error or SFP+ not installed

LINK (Right)

Solid Green Link established

Blinking Green Transmitting the data on the port

Off No link

Page 8: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

7 / 95

1.1.4 Reset Switch (F)

The PRIMERGY 10GbE Connection Blade 18/8 has a reset switch to restart this Connection Blade (hard

reset) and to boot up backup firmware.

Hard Reset:

Push the reset Switch and then release it soon.

Boot up Backup Firmware:

Push the reset switch until port LEDs start blinking green (about 5sec to 10sec) and then release it.

Note

You can enter the backup firm by pressing Ctrl-B while "Booting ..." message is displayed.

1.1.5 Hardware Specifications Table 3 shows the hardware specifications of the PRIMERGY 10GbE Connection Blade 18/8.

Item Specifications

Interface

ETHER(LAN)port

Standard IEEE 802.3

Downlink port(port1-18) 18 ports(10GBASE-KR)

Uplink port(port19-26) 8ports(10GBASE-LR/SR/CR (SFP+))

Management blade

connection port

(oob)

1port

(10/100Base-T,Ethernet connection

via management blade)

Console Port

Standard RS-232C

#of ports 1

Data transfer rate 9600bps

Connection mode Serial connection via management blade

Operating Voltage DC +12 V

Power Consumption Max 36W

External dimensions(H x D x W) 29 x 268 x 193 (mm)

Weight 1.5 kg

Ambient Requirements [Temperature]

On operation:5 ~35 degrees C

Table3. Hardware Specifications

Page 9: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

8 / 95

1.2 Description of Software Table4 shows the supported features by the PRIMERGY 10GbE Connection Blade 18/8

Supported Features

Mode Switch IBP EHM

Cut through/Store and forward

switching selectable

Yes

Yes

Yes

VLAN

Port VLAN Yes Yes Yes

Tag VLAN Yes Yes Yes

Protocol VLAN Yes No Yes

GVRP Yes No Yes

Uplink Set No Yes No

Port Group No Yes No

VLAN Port Group No Yes No

Service LAN No Yes No

Service VLAN No Yes No

Link Down Relay Yes Yes Yes

Link aggregation *5

Static Yes Yes Yes

LACP Yes Yes Yes

Backup port Yes Yes Yes

STP

STP Yes No No

MSTP Yes No No

RSTP Yes No No

QoS(including DiffServ)

Output queue priority control

Strict Yes Yes Yes

DRR Yes Yes Yes

Mapping output queue

CoS value Yes Yes Yes

IPv4 IP Precedence value Yes Yes Yes

IPv6 TC value (high 3 bits) Yes Yes Yes

IPv4 ToS value (using ACLs *2) Yes No Yes

IPv6 TC value (using ACLs *2) Yes No Yes

IPv4 DSCP value (using ACLs *2) Yes No Yes

IPv6 DSCP value (using ACLs *2) Yes No Yes

Rewrite priority

IPv4 DSCP value (using ACLs *2) Yes No Yes

IPv4 ToS value (using ACLs*2) Yes No Yes

IPv6 DSCP value (using ACLs *2) Yes No Yes

Security

IP/MAC filtering *2 Yes No Yes

Log in password Yes Yes Yes

Application filter(per application server) Yes No Yes

IEEE802.1x authentication *3 Yes Yes Yes

Web authentication *3*4 Yes No Yes

MAC address authentication *3 Yes Yes Yes

Guest VLAN Yes No Yes

IPv6 filter Yes No Yes

RADIUS client Yes Yes Yes

TACACS+ client Yes Yes Yes

Page 10: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

9 / 95

Supported Features

Mode Switch IBP EHM

LDAP Client Yes Yes Yes

DoS Yes Yes Yes

Broadcast/Multicast storm control Yes Yes Yes

Port mirroring Yes Yes Yes

Converged Enhanced Ethernet Yes Yes Yes

ether L3 watch Yes Yes Yes

Output rate control Yes Yes Yes

Edge Virtual Switch

Reflective Relay Yes Yes Yes

Routing

IPv4

Static Yes Yes Yes

DHCP Yes Yes Yes

IPv6

Static Yes Yes Yes

DHCPv6 Yes Yes Yes

RA Yes Yes Yes

Multicast

IGMP snooping (v1,v2,v3)(*1) Yes Yes Yes

MLD snooping (v1) Yes Yes Yes

GMRP Yes No Yes

DHCP/DNS client Yes Yes Yes

SNMP(v1,v2,v3) agent Yes Yes Yes

Management configuration

telnet Yes Yes Yes

ssh v2 Yes Yes Yes

Serial(CLI) Yes Yes Yes

WWW browser(Web UI) (including https) Yes Yes Yes

Logging

System log Yes Yes Yes

Error log Yes Yes Yes

Automated time adjustment Yes Yes Yes

Scheduling Yes Yes Yes

Table4. Supported Features

*1)List of sources filtering by EXCLUDE and INCLUDE defined in IGMP v3 membership

report is not supported in IGMPv3

*2) QoS settings using ACLs have no effect on packets to which IP or MAC filter rules apply.

*3) In case of using the authentication with MAC address-based packet admission control,

packets which input to the authentication-enabled port are always flooded when they are

going out from the switch.

*4) If the web authentication with MAC address-based packet admission control is used,

packets which input to a port VLAN for the authentication procedure are also flooded when

they are going out from the switch.

*5) Link aggregation cannot be configured in the port with IEEE802.1x authentication, Web

authentication or MAC address authentication is configured.

1.3 Restrictions and Hints

All SBAX2 interfaces are fix configured with a non changeable MTU size of 9217. When using 1000BASE-SX in SBAX2, we have to disable auto-negotiation in a peer switch.

This restricts the SBAX2 1000BASE-SX connections.

Restriction is only valid for 1000BASE-SX modules, and auto-negotiation needs to be disabled in any SBAX2 peer switches.

Page 11: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

10 / 95

2. Getting Started This chapter describes how to install and configure the PRIMERGY 10GbE Connection Blade 18/8 for

getting started and how to check the system and maintenance information.

2.1 Installing Connection Blade in PRIMERGY

BX900/BX400 Blade Chassis

Install Connection Blade in PRIMERGY BX900/BX400 Blade Chassis with the following procedure. Step1: Insert the Connection Blade with the eject lever open in PRIMERGY BX900/BX400 Blade Chassis

Step2: Push the eject lever and close it.

2.2 Installing SFP+ Module in Connection Blade Install SFP+ module in Connection Blade with the following procedure. Step1: Insert the SFP+ module with the lever closed in SFP+ port of Connection Blade

Figure5. Installing SFP+ module

Lever

Page 12: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

11 / 95

2.3 Setting up serial console connection This section shows how to set up serial console connection to access connection blade CLI

Step1: Connect MMB and PC console port with a console cable. Or use a telnet / SSH session to the MMB

Step2: Configure terminal software in PC as follows.

- 8 data bits, 1 stop bit and no parity - 115200 baud - No flow control

Step3: Login MMB CLI. (username : admin, password : admin in default) Step4: Enter 3 in Console Menu.

Console Redirection Table Menu appears.

+-----------------------------------------------------------------------------+ | Console Redirection Table page_3 +-----------------------------------------------------------------------------+ (1) Console Redirect Connection Blade

(2) Set Return Hotkey , Ctrl+(a character) : Q (3) Set Console Redirection Timeout : 900 Enter selection or type (0) to quit:

Step5: Enter the connection blade number which you’d like to configure.

+------------------------------------------------------------------------------+

| Console Redirect Connection Blade page_3_1 +------------------------------------------------------------------------------+ (1) Console Redirect Connection Blade-1

(2) Console Redirect Connection Blade-2 (3) Console Redirect Connection Blade-3 (4) Console Redirect Connection Blade-4

(5) Console Redirect Connection Blade-5 (6) Console Redirect Connection Blade-6 Enter selection or type (0) to quit: 3

Page 13: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

12 / 95

2.4 Configuring Connection Blade with connection

blade CLI This section explains how to configure basic settings like IP address, default gateway and password.

Step1: Login CLI by entering username and password (username:admin, password:admin in default)

Login: admin Password: <WARNING> weak admin's password: contain at least 8 characters

# Step2: Enter configure to move configuration mode.

# configure (config)#

Step3: Configure IP address of oob (out of band) port.

Example) assign 192.168.1.10/24 to oob port

(config)# oob ip address 192.168.1.10/24 3

Step4: Configure default gateway

Example) assign 192.168.1.1 to default gateway

(config)# oob ip route 0 default 192.168.1.1 1 1

Step5: Check if oob IP address has been set correctly by show oob command.

(config)#exit # show oob

IP Address : 192.168.1.10 Subnet Mask : 255.255.255.0 MAC Address : 00:17:42:d1:09:60 MMB Ethernet: MMB1

Page 14: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

13 / 95

Step6: Check if default gateway has been set correctly by show ip route.

# show ip route

FP Destination/Mask Gateway Distance UpTime Interface --- -------------------- --------------- ---------- --------- ---------- *S 0.0.0.0/0 192.168.1.1 1 00:00:17 oob0

*C 192.168.1.0/24 192.168.1.10 0 00:00:17 oob0

Step7: Configure login password

# configure (config)#password admin set **************

2.5 Command Mode

This section describes the command mode of CLI. Figure6 shows the transition diagram of command mode.

Figure6 Transition Diagram of Command Line Interface

Logout (Initial State)

Power On Reset Switch Reset Command

User Exec

Privileged Exec

User Login Admin

Login

exit / quit quit

enable

disable / exit

configure Exit / end

Global Config

Interface Config

Line Config

interface <n>

exit

line

<name>

exit

Logout

Login

Ctrl + Z Exec Mode

Configuration Mode

Page 15: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

14 / 95

Table5 shows the explanation for each command mode.

Mode Description

Logout/Login SBAX2 is to be Logout state after power on, reset switch, reset command.

User Exec Mode You can move to User Exec mode with entering user name and user password in logout state. Only a limited Exec mode command is available in this mode.

Privileged Exec Mode You can move to Privileged Exec Mode with entering admin and admin password in logout state or entering enable command and admin password.

All Exec mode command is available in this mode.

Global Config Mode You can move to Global Config Mode with entering

configure command in Privileged Exec mode. Configuration mode command is available except interface config mode command and Line confog mode command.

Interface Config Mode You can move to interface config mode with entering interface command. You can configure ethernet port

parameter in this mode.

Line Config Mode You can move to Line config mode with entering line

command. You can configure terminal.

Table5 Command mode

Table6 shows CLI error message List.

Error Message Description

<Error> command name: Unknown

Command

-Unknown command

-Can not be execute in the current

command mode

<Error>command name: Operation not

permitted

-not permitted to execute the command

<Error>:0: argument too less -argument is too less

<Error>:0: argument too much -argument is too much

<Error>:position of argument: format error -Format of argument is not correct

<Error>:position of argument: value out of

range

-Value of argument is out o range

<Error>:position of argument: lack of table -Definition is over limit

<Error>:position of argument: no such table -Definition is not found

<Error>:position of argument: duplicate value

-Definition is duplicate

<Error>:position of argument: fail to request -Failed to execute command

<Error>:position of argument: unique password

- Password is not unique

<Error>:detected HARD ERROR, cannot execute

- cannot execute because of hard error

Table6 CLI Error message list

Page 16: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

15 / 95

2.6 Changing Switch Mode ,IBP Mode and EHM

The PRIMERGY 10GbE Connection Blade 18/8 boots up with EHM in default*1. You can change the mode to Switch mode or IBP mode by the boot-system mode

command. After reboot, the PRIMERGY 10GbE Connection Blade 18/8 boots up

with the mode specified by boot-system mode command. *2

Change mode to switch mode

# boot-system mode switch # reset

Change mode to IBP mode

# boot-system mode ibp # reset

You can change back mode to ehm

# boot-system mode ehm # reset

You can check current mode with <show system information> command. *1 EHM is supported in V03.00 NYxxxx firmware. V02.00 NYxxxx firmware doesn’t support EHM.

In V02.00 NYxxxx firmware, default mode is switch mode.

*2 If your PRIMERGY 10GbE Connection Blade 18/8 is running with V02.00 NYxxxx and you’d like to

use EHM from now on, please follow the procedure below.

<Procedure> 1) Update the firmware from V02.00 NYxxxx to V03.00 NYxxxx

2) Power Cycle the connection blade By Reinsert Connection blade or Reset Conenction Blade via MMB

3) Change the mode to ehm

# boot-system mode ehm # reset

4) Login EHM

Login EHM with admin for login name and w/o password (just enter [Enter] key for password)

Login:admin Password:

5) Reset EHM

# reset clear

6) Login ehm

Login ehm with admin for login name and password.

Login:admin

Password:admin

Page 17: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

16 / 95

2.7 Checking version and system information This section describes how to check version and system information.

2.7.1 Checking version and firmware information

You can check version and firmware information with <show system information> command.

# show system information Current-time : Sat Apr 11 20:24:33 GMT 2009 -------1)

Startup-time : Sat Apr 11 20:14:22 GMT 2009 -------2) Hardware Version : C0-07 -------3) Number of ports : 18/8 -------4)

Machine Model : PY CB Eth Switch/IBP 10Gb 18/8 -------5) ROM Ver. : 2.2 -------6) ASIC Firm Ver. : 090203PL1 -------7)

Firm Ver. : V01.00 NY0013 Mon Mar 9 20:40:36 JST 2009 -------8) Startup-firmware : switch_firm -------9) Next-boot : switch_firm -------10) Startup-config : Thu Jan 1 00:00:00 GMT 1970 config1 -------11)

Running-config : Sat Apr 11 20:14:22 GMT 2009 -------12) MAC : 001742d10960 -------13) Memory : 128MB -------14)

1) Current time

Current time is displayed

2) Startup time

Time which system booted up on is displayed

3) Hardware Version

Hardware version is displayed

4) Number of ports

The port number of 10GbE is displayed (downlink ports/uplink ports)

5) Machine Model

Machine model is displayed

6) ROM Ver.

Boot ROM version is displayed.

8) Firm Ver.

Firmware version is displayed

When switch software is operating, switch firmware version is displayed.

When IBP software is operating, IBP firmware version is displayed.

9) Startup-firmware

Current operating software mode (Switch or IBP) is displayed

10) Next-boot

Software mode in next boot is displayed

11) Startup-config

Startup config information is displayed.

Page 18: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

17 / 95

12) Running-config

Running config information is displayed

13) MAC

MAC address is displayed

14) Memory

Memory size is displayed

2.7.2 Checking System information

You can check the system information with show system status command. # show system status

Current-time : Sat Apr 11 21:03:17 GMT 2009 --------1) Startup-time : Sat Apr 11 20:14:22 GMT 2009 --------2) restart_cause : power on --------3)

machine_state : RUNNING --------4) power_consumption : 24 W --------5)

1) Current time

Current time is displayed

2) Startup time

Time which system booted up on is displayed

3) restart cause

System restart cause is diplayed

4) machine state

Machine state is displayed

5) power consumption

Current power consumption is displayed

Page 19: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

18 / 95

2.8 Configuration files The PRIMERGY 10GbE Connection Blade 18/8 has 2 configuration files for each EHM configuration, switch mode configuration and IBP mode configuration.

Figure7 Configuration file structure

2.8.1 Changing startup configuration file

You can change startup configuration file with the following command.

(Changing startup configuration from config1 to config2)

#reset config2

2.8.2 Checking configuration file

You can check the running configuration with show runnig-config command

#show running-config

You can check the startup-configuration with show startup-config command #show startup-config

2.8.3 Saving configuration

You can save the current running configuration in startup configuration with save command.

(config)#save You can save the current running configuration in config2 with the following command.

(config)#save config2 ? free choice of naming? No. Name is config1 or config2

? how can I see which config file name is startup ?

config1

config2

config1

config2

EHM IBP Mode

PRIMERGY 10GbE Connection Blade 18/8

Configuration file1 for IBP software

Configuration file2 for IBP software

Configuration file1 for EHM

Configuration file2 for EHM 構成定義情報 2

config1

config2

Switch Mode

Configuration file1 for Switch Mode

Configuration file2

for Switch Mode 構成定義情報 2

Page 20: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

19 / 95

2.8.4 Backup/Restore configuration You can backup/restore configuration file in/from a remote console with ftp command

Figure8 Backup/Restore Configuration

Backup Configuration

Example) backup config1 in C:<config of FTP client with file name “config1-1”

C:<config>ftp 192.168.1.10 Connect with FTP to Connection Blade

User (192.168.1.100:(none)): admin Enter User Name 331 Password required for admin. Password: Enter Password

230 User admin logged in. ftp> bin Change to binary mode 200 Type set to I ftp>get config1 config1-1 backup config1 to config1-1 file ・

ftp>bye 221 Goodbye C:<config>

FTP Client 192.168.1.100/24

oob port

192.168.1.10/24

Backup configuration Get configuration with

ftp command

Restore configuration Put configuration with ftp command

Page 21: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

20 / 95

Restore Configuration Example) Restore config1-1 to config1.

C:<config>ftp 192.168.1.10 Connect with FTP to Connection Blade

User (192.168.1.100:(none)): admin Enter User Name 331 Password required for admin. Password:admin Enter Password

230 User admin logged in. ftp> bin Change to binary mode 200 Type set to I

ftp>put config1-1 config1 Restore config1-1 to config1 ・

226 Write complete 2856 bytes sent in 1.10 seconds (2.44 Kbytes/s)

ftp>get reset Restart connection blade ・

ftp>bye 221 Goodbye C:<config>

2.8.5 Clearing Configuration

You can clear configuration with reset clear command.

#reset clear

2.9 Updating Firmware

You can update firmware with the following procedure.

Example) Updating Firmware in figure 8 configuration.

C:<firm>ftp 192.168.1.10 Connect with FTP to Connection Blade User (192.168.1.100:(none)): admin Enter User Name

331 Password required for admin. Password:admin Enter Password 230 User admin logged in.

ftp> bin Change to binary mode ftp> put SBAX2V0200BIND_NY48 bindfirm Update firmware

Firmware Put command

BIND Firmware put <firmware filename> bindfirm

Firmware is applied after hard reset.

<Note>

If your PRIMERGY 10GbE Connection Blade 18/8 is running with V02.00 NYxxxx and you’d like to

use EHM from now on, please see Chapter 2.6.

Page 22: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

21 / 95

2.10 Initializing Connection Blade with Backup Firm You can initialize The PRIMERGY 10GbE Connection Blade 18/8 and back to factory default with backup firmware.

Step1: Boot up The PRIMERGY 10GbE Connection Blade 18/8. Step2: Press [Ctrl + B] key during displaying Booting…

Backup firmware boot up.

Booting ... Backup firmware mode.

Step3: Enter the following commands

>logon Logon backup firmware backup# reset clear Initialize and reboot

2.11 Recovery Firmware with Backup Firm You can recovery firmware with backup firm if switch software and IBP software are corrupted.

Step1: Logon backup firmware with 2.10 procedure. Step2: Configure oob ip address with the following commands

backup# oob ip address 192.168.1.10/24 3 backup# commit

Step3: logout backup firmware

backup# exit >

Step4: Update firmware with ftp command from ftp client.

Page 23: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

22 / 95

3. Configuring Switch Software

This chapter describes how to configure switch software functions.

3.1 Configuring VLAN

3.1.1 Configuring untag VLAN This section describes how to configure untag VLAN.

<Configuration target>

Assign Interface0/1 to untag VLAN(VID10)

Assign Interface0/5 to untag VLAN(VID20) Assign IP address(192.168.20.1/24) VLAN(VID20).

<Commands> (config)#interface 0/1

(config-if)#vlan untag 10

(config)#interface 0/5 (config-if)#vlan untag 20

Assign IP address(192.168.20.1/24) to VLAN(VID20) (config)#lan 0 ip address 192.168.20.1/24 3

(config)#lan 0 vlan20 Save the configuration

(config)#save

3.1.2 Configuring tag VLAN This section describes how to configure tag VLAN.

<Configuration target>

Assign Interface0/1 to tag VLAN(VID10)

Assign Interface0/5 to tag VLAN(VID20) Assign VLAN(VID20) to IP address(192.168.20.1/24)

<Commands> (config)#interface 0/1

(config-if)#vlan tag 10,20

(config)#interface 0/5 (config-if)#vlan tag 10,20

Assign IP address(192.168.20.1/24) to VLAN(VID20) (config)#lan 0 ip address 192.168.20.1/24 3

(config)#lan 0 vlan20

Save the configuration (config)#save

Page 24: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

23 / 95

3.1.3 Configuring protocol VLAN This section describes how to configure protocol VLAN which IP protocol packets are sent/received with VLAN10 and VLAN20. Packets except IP protocol are sent/received with

VLAN100.

<Configuration target>

Assign Interface0/1 to untag VLAN(VID10,100) Assign Interface0/5 to untag VLAN(VID20,100)

Assign VLAN10,20 to IPv4 Protocol VLAN Assign IP address(192.168.20.1/24) to VLAN(VID20)

<Commands>

(config)#interface 0/1

(config-if)#vlan untag 10,100

(config)#interface 0/5 (config-if)#vlan untag 20,100

(config)#vlan 10 protocol ipv4

(config)#vlan 20 protocol ipv4

(config)#lan 0 ip address 192.168.20.1/24 3 (config)#lan 0 vlan20

Save the configuration

(config)#save

Page 25: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

24 / 95

3.2 Configuring Link Aggregation

3.2.1 Configuring Static Link Aggregation

This section describes how to configure link aggregation without LACP with 4 links.

<Configuration target>

Configure static link aggregation with Interface0/19-0/22 Assign IP address(192.168.20.1/24) to VLAN(VID20)

<Commands>

SBAX2#1 Assign Interface0/19-0/22 to tag VLAN(VID10,20)

(config)#interface range 0/19-0/22

(config-if)#vlan tag 10,20

Configure static link aggregation with Interface0/19-0/22 (config)#interface range 0/19-0/22

(config-if)#type linkaggregation 1 (config-if)#vlan untag 20

Assign VLAN(VID20) to IP address(192.168.20.1/24)

(config)#lan 0 ip address 192.168.20.1/24 3

(config)#lan 0 vlan20

Save the configuration (config)#save

SBAX2#2

Assign Interface0/19-0/22 to tag VLAN(VID10,20) (config)#interface range 0/19-0/22

(config-if)#vlan tag 10,20

Configure static link aggregation with Interface0/19-0/22

(config)#interface range 0/19-0/22 (config-if)#type linkaggregation 1

(config-if)#vlan untag 20

Assign IP address(192.168.20.2/24) to VLAN(VID20) (config)#lan 0 ip address 192.168.20.2/24 3

(config)#lan 0 vlan20

Save the configuration

(config)#save

SBAX2#1 SBAX2#2

Page 26: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

25 / 95

3.2.2 Configuring Link Aggregation with LACP

This section describes how to configure link aggregation with LACP with 4 links.

<Configuration target>

Configure link aggregation with LACP with Interface0/19-0/22 Assign VLAN(VID20) to IP address(192.168.20.1/24)

<Commands>

SBAX2#1 Assign Interface0/19-0/22 to tag VLAN(VID10,20)

(config)#interface range 0/19-0/22

(config-if)#vlan tag 10,20

Configure link aggregation with LACP with Interface0/19-0/22 and set active mode (config)#interface range 0/19-0/22

(config-if)#type linkaggregation 1 (config)#linkaggregation 1 mode active

Assign IP address(192.168.20.1/24) to VLAN(VID20)

(config)#lan 0 ip address 192.168.20.1/24 3

(config)#lan 0 vlan20

Save the configuration (config)#save

SBAX2#2

Assign Interface0/19-0/22 to tag VLAN(VID10,20) (config)#interface range 0/19-0/22

(config-if)#vlan tag 10,20

Configure link aggregation with LACP with Interface0/19-0/22 and set active mode

(config)#interface range 0/19-0/22 (config-if)#type linkaggregation 1

(config)#linkaggregation 1 mode active

Assign IP address(192.168.20.2/24) to VLAN(VID20) (config)#lan 0 ip address 192.168.20.2/24 3

(config)#lan 0 vlan20

Save the configuration

(config)#save

SBAX2#1 SBAX2#2

Page 27: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

26 / 95

3.3 Configuring Backup Port This section describes how to configure backup port.

<Configuration target> Configure backup port group with interface0/19,0/26 and set 0/19 to master port and 0/26 to

backup port. Configure master port to preference port

<Commands>

Configure Interface0/19 to master port of backup port(group1).

SBAX2(config)#interface 0/19 SBAX2(config-if)#type backup 1 master

Configure Interface0/26 to backup port port of backup port(group1).

(config)#interface 0/26 (config-if)#type backup 1 backup

Configure backup group1 to master port preference mode.

(config)#backup 1 mode master

Save the configuration

(config)#save

Switch Switch

Master Port Slave Port

Page 28: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

27 / 95

3.4 Configuring MAC filtering

This section describes how to configure MAC filtering which can limit network traffic and restrict network for security with combination of MAC address, Packet , Ethernet type, VLAN

ID and CoS value.

<Filtering Condition>

Packet data flow can be controlled by specifying the following parameter. 1) Specify ACL MAC definition and ACL VLAN definition for filter

- Source MAC Information(MAC address/Packet format /Ethernet Type/LSAP)

- Destination MAC Information(MAC address/Packet format/Ethernet Type/LSAP)

- VLAN ID

- CoS Value

- Source IP Information(IP Address/Address Mask)

- Destination IP Information(IP Address/Address Mask)

- Protocol - TCP/UDP port number

- ICMP TYPE、ICMP CODE

- TOS value、DSCP value of IP packet

2) Specify the interface for MAC filter

3) Specify action (reject or pass) for MAC filter

Unexpected Connection

Unpected access

Wrong Access

Allowed Access

Allowed Server

Page 29: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

28 / 95

<Filtering design policy>

There are two way for filtering design. A. Pass the specified packets and reject the others.

B. Reject the specified packets and pass the others.

This chapter explains the following examples for A. -Pass only packets of the specified source MAC address.

-Pass only packets of the specified destination MAC address.

And explains the following example for B.

-Reject only packets of the specified packet format.

3.4.1 Configuring MAC filter 1

This section describes how to configure MAC filter which passes only packets of the specified

source MAC address and rejects the other packets.

<Filtering Design> VLAN 10 consists of interface0/1-0/8 and they are untag VLAN.

VLAN 20 consists of interface0/1-0/4 and interface0/9-0/12.Interface0/1-0/4 is tag VLAN and Interface0/9-0/12 is untag VLAN.

Interface0/4-0/8 in VLAN 10 pass packets of the only source MAC address00:0b:01:02:03:04 and rejects the other packets.

<Commands>

Configure ACL which specifies source MAC address 00:0b:01:02:03:04 and VLAN 10.---(1)

(config)#acl 100 mac 00:0b:01:02:03:04 any any (config)#acl 100 vlan 10 any

Configure ACL which specifies all packet format of VLAN10. --- (2)

(config)#acl 110 vlan 10 any

Configure mac filter which pass packets specified by (1) in interface0/2.

(config)#interface 0/2

(config-if)#macfilter 0 pass 100

Configure mac filter which rejects packets specified by (2) in interface0/2. (config)#interface 0/2

(config-if)#macfilter 1 reject 110

Page 30: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

29 / 95

3.4.2 Configuring MAC filter 2

This section describes how to configure MAC filter which passes only packets of the specified destination MAC address and rejects the other packets.

<Filtering Design> VLAN 10 consists of interface0/1-0/8 and they are untag VLAN.

VLAN 20 consists of interface0/1-0/4 and interface0/9-0/12.Interface0/1-0/4 is tag VLAN and Interface0/9-0/12 is untag VLAN.

Interface0/4-0/8 in VLAN 10 pass packets of the only destination MAC address00:0b:01:02:03:04 and rejects the other packets.

<Commands>

Configure ACL which specifies destination MAC address 00:0b:01:02:03:04 and VLAN 10.---(1) (config)#acl 120 mac any 00:0b:01:02:03:04 any (config)#acl 120 vlan 10 any

Configure ACL which specifies all packet format of VLAN10. --- (2) (config)#acl 110 vlan 10 any

Configure mac filter which pass packets specified by (1) in interface0/4-0/8 (config)#interface range 0/4-0/8 (config-if)#macfilter 0 pass 120

Configure mac filter which rejects packets specified by (2) in interface0/4-0/8 (config)#interface range 0/4-0/8

(config-if)#macfilter 1 reject 110

3.4.3 Configuring MAC filter 3

This section describes how to configure MAC filter which rejects only packets of the specified destination MAC address and passes the other packets.

<Filtering Design>

VLAN 10 consists of interface0/1-0/8 and they are untag VLAN. VLAN 20 consists of interface0/1-0/4 and interface0/9-0/12.Interface0/1-0/4 is tag VLAN and

Interface0/9-0/12 is untag VLAN. Interface0/1-0/4 rejects IP protocol packets and passes the other packets.

<Commands> Configure ACL which specifies IP protocol(IP,ARP,Reserve ARP) ---(1) (config)#acl 130 mac any any ether 0800 (config)#acl 131 mac any any ether 0806

(config)#acl 132 mac any any ether 8035

Configure mac filter which rejects packets specified by (1) in interface0/1-0/4

and rejects packets specified by (2) in interface0/4-0/8

(config)#interface range 0/1-0/4

(config-if)#macfilter 0 reject 130 (config-if)#macfilter 1 reject 131 (config-if)#macfilter 2 reject 132

Page 31: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

30 / 95

3.4.4 Configuring MAC filter 4 This section describes how to configure MAC filter which rejects only the traffic between the specified MAC addresses.

<Filtering Design>

VLAN 10 consists of interface0/1-0/4 with untag and 0/5-0/8 with tag. VLAN 20 consists of interface0/1-0/4 with tag and interface0/5-0/8 with tag.

In VLAN10, Only TCP Traffic is rejected between MAC address 00:0b:01:02:03:04 and

00:0b:11:12:13:14 In VLAN20, Only UDP traffic is rejected between MAC address 00:0b:21:22:23:24 and

00:0b:31:32:33:34.

<Commands> Configure ACL which specifies TCP packets of source MAC address 00:0b:01:02:03:04 and destination

MAC address 00:0b:11:12:13:14. --- (1) (config)#acl 0 00:0b:01:02:03:04 00:0b:11:12:13:14 any (config)#acl 0 ip any any 6 any

Configure ACL which specifies TCP packets of source MAC address 00:0b:11:12:13:14 and destination MAC address 00:0b:01:02:03:04. --- (2) (config)#acl 1 00:0b:11:12:13:14 00:0b:01:02:03:04 any

(config)#acl 1 ip any any 6 any Configure ACL which specifies UDP packets of source MAC address 00:0b:21:22:23:24 and destination

MAC address 00:0b:31:32:33:34. --- (3) (config)#acl 2 00:0b:21:22:23:24 00:0b:31:32:33:04 any (config)#acl 2 ip any any 17 any

Configure ACL which specifies UDP packets of source MAC address 00:0b:31:32:33:34 and destination MAC address 00:0b:21:22:23:24. --- (4) (config)#acl 3 00:0b:21:22:23:24 00:0b:31:32:33:04 any

(config)#acl 3 ip any any 17 any Configure mac filter which rejects packets specified by (1) and (2) in VLAN10.

(config)#vlan 10 macfilter 0 reject 0 (config)#vlan 10 macfilter 1 reject 1 Configure mac filter which rejects packets specified by (3) and (4) in VLAN20.

(config)#vlan 20 macfilter 0 reject 2 (config)#vlan 20 macfilter 1 reject 3

Page 32: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

31 / 95

3.4.5 Configuring MAC filter 5 This section describes how to configure MAC filter which passes only the traffic between the specified MAC addresses.

<Filtering Design> VLAN 10 consists of interface0/1-0/4 with untag and 0/5-0/8 with tag.

VLAN 20 consists of interface0/5-0/8 with untag. In VLAN10, Only IP protocol packets are passed.

In VLAN20, Only FNA protocol packets are passed.

<Commands> Configure ACL which specifies IP protocol(IP,ARP,Reserve ARP) ---(1)

(config)#acl 10 mac any any ether 0800 (config)#acl 11 mac any any ether 0806 (config)#acl 12 mac any any ether 8035

Configure ACL which specifies FNA format---(2) (config)#acl 20 mac any any llc 8080

(config)#acl 21 mac any any llc 0000 (config)#acl 22 mac any any llc 0001 Configure ACL which specifies all packets-----(3)

(config)#acl 30 mac any any any Configure mac filter which rejects packets except packets specified by (1) in VLAN10 ---(4)

(config)#vlan 10 macfilter 0 pass 10 (config)#vlan 10 macfilter 1 pass 11 (config)#vlan 10 macfilter 2 pass 12

(config)#vlan 10 macfilter 3 reject 30 Configure mac filter which rejects packets except packets specified by (2) in VLAN20 -----(5) (config)#vlan 20 macfilter 0 pass 20

(config)#vlan 20 macfilter 1 pass 21 (config)#vlan 20 macfilter 2 pass 22 (config)#vlan 20 macfilter 3 reject 30

Page 33: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

32 / 95

3.5 Configuring Static MAC forwarding

This Section describes how to add MAC address to FDB as static entries.

MAC address can be manually entered in FDB which doesn’t age out and you can avoid flooding of extra frames to network.

<Configuration target>

Assign Interface0/2, 0/5 which Server#1,#2 are connected to VLAN(VID10).

Assign Interface0/10 which Server#3 is connected to VLAN(VID20). Add MAC address of Servers to FDB as static entry.

Server#1 MAC address: 00:00:00:00:00:11 Server#2 MAC address: 00:00:00:00:00:22

Server#2 MAC address: 00:00:00:00:00:33

<Commands> Assign Interface0/2 and 0/5 to untag VLAN(VID10) (config)#interface range 0/2,0/5 (config-if)#vlan untag 10

Assign Interface0/10 to untag VLAN(VID20) (config)#interface 0/10

(config-if)#vlan untag 20 Add MAC address to FDB in VLAN10. (config)#vlan 10 forward 0 00:00:00:00:00:11 2

(config)#vlan 10 forward 1 00:00:00:00:00:22 5 Add MAC address to FDB in VLAN20.

(config)#vlan 20 forward 0 00:00:00:00:00:33 10

Save the configuration

(config)#save

Server#1 Server#2

VLAN10 VLAN20

Server#3

Page 34: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

33 / 95

3.6 Configuring QoS

3.6.1 Configuring priority control This section describes how to configure priority control which assigns egress port queue of

different priority to User priority value(Cos) in VLAN tag.

<Priority Control Design>

Packet Type CoS

Value

Queue class

Managemnet 7

4 6

Voice 5 3

FAX 4 2

Movie 3

1 2

Other 1 0

0

<Commands>

(config)#interface 0/1 (config-if)#qos prioritymap 0 0

(config-if)#qos prioritymap 1 0 (config-if)#qos prioritymap 2 1

(config-if)#qos prioritymap 3 1 (config-if)#qos prioritymap 4 2

(config-if)#qos prioritymap 5 3

(config-if)#qos prioritymap 6 4 (config-if)#qos prioritymap 7 4

Page 35: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

34 / 95

3.6.2 Configuring priority control rewrite

This section describes how to configure priority control rewrite which rewrites priority control information of packets specified with combination of Mac address, packet format, Ethernet

type, VLAN ID and CoS value.

<Rewrite Condition>

Priority control information can be controlled by specifying the following parameter. 1)Specify ACL MAC definition and ACL VLAN definition for filter

- Source MAC Information(MAC address/Packet format /Ethernet Type/LSAP)

- Destination MAC Information(MAC address/Packet format/Ethernet Type/LSAP)

- VLAN ID

- CoS Value

- Source IP Information(IP Address/Address Mask)

- Destination IP Information(IP Address/Address Mask)

- TCP/UDP port number

- ICMP TYPE、ICMP CODE

- TOS value、DSCP value of IP packet

2)Specify the interface for MAC filter

3)Specify action(reject or pass) for MAC filter - Rewrite DSCP value

- Rewrite ip precedence value - Change queue which the received packets in ingress port use in egress port.

DSCP value rewrite

This section describes how to configure DSCP value rewrite of all ingress packets in the specified interfaces in VLAN.

<Rewrite request>

VLAN 10 consists of interface0/1-0/8 and they are tag VLAN. DSCP value of all packets is rewrite to 40 in interface0/1.

<Commands> Configure ACL which specifies all packets --- (1)

(config)#acl 120 mac any any any

Configure DSCP value rewrite which rewrites DSCP value of packets specified by (1) to 40

(config)#interface 0/1 (config-if)#qos aclmap 0 dscp 40 120

Save the configuration

(config)#save

Page 36: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

35 / 95

IP Precedence value rewrite This section describes how to configure IP precedence value rewrite which rewrites IP precedence value of packets which has the specified CoS value in the specified port in VLAN.

<Rewrite request> VLAN 10 consists of interface0/1-0/8 and they are tag VLAN.

IP precedence value of packets which have CoS value 5 is rewrite to 40 in VLAN10.

<Commands> Configure ACL which specifies packets of VLAN ID10 and CoS value 5 ---(1) (config)#acl 150 vlan 10 5

Configure QoS ACL map which rewrites ip precedence value of packets specified by (1) to 6 in interface0/1-0/8 in VLAN10.

(config)#interface range 0/1-0/8 (config-if)#qos aclmap 0 tos 6 150

Save the configuration

(config)#save

Change queue of packets in VLAN

This section describes how to configure change queue function which changes queue which the received

packets in ingress port use in egress port.

<Rewrite request>

VLAN20 consists of interface0/1-0/5 and 0/1-0/4 is tag VLAN. 0/5 is untag VLAN.

Queue of packets of source Mac address 00:0b:01:02:03:04 is changed to 3.

<Commands> Configure ACL which specifies source MAC address 00:0b:01:02:03:04 ---(1) (config)#acl 100 mac 00:0b:01:02:03:04 any any

Configure QoS ACL map which changes queue of packets specified by(1) in VLAN20. (config)#vlan 20 qos aclmap 0 queue 3 100

Save the configuration (config)#save

Page 37: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

36 / 95

3.7 Configuring Spanning Tree

This section describes how to configure STP.

3.7.1 Configuring STP

<Configuration target> Enable STP Assign Interface0/17 and 0/26 to VLAN(VID10)

<Commands> Assign Interface0/17 and 0/26 to VLAN(VID10) (config)#interface range 0/17-0/26

(config-if)#vlan untag 10 Enable STP in Interface0/1 and 0/2.

(config)#interface range 0/1-0/2 (config-if)#stp use on

Save the configuration (config)#save

Switch Switch

Page 38: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

37 / 95

3.7.2 Configuring MSTP This section describes how to configure MSTP. MSTP can handle frames per VLAN.

<Configuration Target> Control frames per VLAN by using MSTP in the following VLAN environment.

[Instance 0] Bridge Priority: SBAX2#1 -> SBAX2#2 -> SBAX2#3 -> SBAX2#4

[Instance 1] Bridge Priority: SBAX2#1 -> SBAX2#2 -> SBAX2#3 -> SBAX2#4 VLAN 100、200

[Instance 2]

Bridge Priority: SBAX2#1 -> SBAX2#3 -> SBAX2#2 -> SBAX2#4 VLAN 300

<SBAX2#1> Connect interface0/19 to SBAX2#2 Connect interafce0/26 to SBAX2#3

Configure STP path cost of interface 0/19 and 0/26 to 20000 for all instances.

SBAX2#1

SBAX2#2

SBAX2#4

SBAX2#3

VLAN100,200

VLAN300

Page 39: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

38 / 95

<SBAX2#2> Connect interface0/19 to SBAX2#1

Connect interafce0/23 to SBAX2#3 Connect interafce0/26 to SBAX2#4 Configure STP path cost of interface 0/19,0/23 and 0/26 to 20000 for all instances.

<SBAX2#3> Connect interface0/19 to SBAX2#1 Connect interafce0/23 to SBAX2#2 Connect interafce0/26 to SBAX2#4

Configure STP path cost of interface 0/19,0/23 and 0/26 to 20000 for all instances. <SBAX2#4>

Connect interface0/19 to SBAX2#2 Connect interafce0/26 to SBAX2#3 Configure STP path cost of interface 0/19 and 0/26 to 20000 for all instances.

Connect the servers of VLAN100 to interface0/20-0/21. Connect the servers of VLAN200 to interface0/22. Connect the servers of VLAN300 to interface0/24-0/25.

<Command>

SBAX2#1 Configure STP path cost in interface0/19、0/23.

(config)#interface range 0/19,0/23 (config-if)#stp domain 0 cost 20000

(config-if)#stp domain 1 cost 20000 (config-if)#stp domain 2 cost 20000

Configure VLAN

(config)#interface range 0/19,0/23

(config-if)#vlan tag 100,200,300 Configure STP

(config)#stp mode mstp (config)#stp domain 1 vlan 100,200 (config)#stp domain 2 vlan 300

(config)#stp domain 0 priority 4096 (config)#stp domain 1 priority 4096 (config)#stp domain 2 priority 4096

Save the configuration

(config)#save

Page 40: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

39 / 95

SBAX2#2 Configure STP path cost in interface0/19、0/23、0/26

(config)#interface range 0/19,0/23,0/26 (config-if)#stp domain 0 cost 20000

(config-if)#stp domain 1 cost 20000

(config-if)#stp domain 2 cost 20000

Configure VLAN

(config)#interface range 0/19,0/23,0/26

(config-if)#vlan tag 100,200,300 Configure STP (config)#stp mode mstp

(config)#stp domain 1 vlan 100,200 (config)#stp domain 2 vlan 300 (config)#stp domain 0 priority 8192

(config)#stp domain 1 priority 8192 (config)#stp domain 2 priority 12288

Save the configuraton (config)#save

SBAX2#3 Configure STP path cost in interface0/19、0/23、0/26

(config)#interface range 0/19,0/23,0/26 (config-if)#stp domain 0 cost 20000 (config-if)#stp domain 1 cost 20000

(config-if)#stp domain 2 cost 20000

Configure VLAN

(config)#interface range 0/19,0/23,0/26 (config-if)#vlan tag 100,200,300

Configure STP (config)#stp mode mstp

(config)#stp domain 1 vlan 100,200 (config)#stp domain 2 vlan 300 (config)#stp domain 0 priority 12288 (config)#stp domain 1 priority 12288

(config)#stp domain 2 priority 8192

Save the configuration (config)#save

Page 41: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

40 / 95

SBAX2#4 Configure STP path cost in interface0/19、0/26

(config)#interface range 0/19,0/26

(config-if)#stp domain 0 cost 20000 (config-if)#stp domain 1 cost 20000 (config-if)#stp domain 2 cost 20000

Configure VLAN

(config)#interface range 0/19,0/26 (config-if)#vlan tag 100,200,300

Configure STP (config)#stp mode mstp (config)#stp domain 1 vlan 100,200

(config)#stp domain 2 vlan 300 (config)#stp domain 0 priority 32768 (config)#stp domain 1 priority 32768 (config)#stp domain 2 priority 32768

Save the configuration

(config)#save

Page 42: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

41 / 95

3.8 Configuring IGMP Snooping SBAX2 detects the port which requires multicast packets and transfers multicast packets to just the port

by using IGMP snooping. This constrains the flooding of multicast traffic and avoids transferring unnecessary multicast packets to servers.

<Configuration target> Use IGMP snooping Listner#1 Port: Interface0/1,0/2 VLAN: 10

Listener#2 Port:Interface0/3,0/4 VLAN:11

Lsitener#3 Port:Interface0/5,0/6 VLAN:12

Multicast router#1 is connected to interface0/25 which VLAN10-12 is assigned with tag VALN. Multicast router#2 is connected to interface0/26 which VLAN10 is assigned with tag VALN.

Munlicast

Router#1 Multicast Router#2

Sender Sender

Listener Listener Listener Listener

Page 43: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

42 / 95

<Commands> Enable IGMP snooping (config)#igmpsnoop use on

(config)#interface range 0/1-0/2 vlan untag 10

(config-if)vlan untag 10 (config)#interface 0/3-0/4

(config-if)#vlan untag 11 (config)#interface 0/5-0/6 (config-if)#vlan untag 12 (config)#interface 0/25

(config-if)#vlan tag 10,11,12 (config)#interface 0/26 (config-if)#vlan untag 10

Configure the multicast port for VLAN10 which multiple multicast routers are connected

(config)#vlan 10 igmpsnoop router yes 25,26

Save the configuration

(config)#save

Page 44: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

43 / 95

3.9 Configuring IEEE802.1X Authentication This section describes how to configure IEEE802.1X authentication.

Note

Don’t assign VLAN ID to ports which use IEEE802.1X authentication.

Configure AAA group ID correctly for IEEE802.1X authentication. Only EAP-MD5 can be used as authentication method for local authentication. The following accounting information can not be gotten correctly in multiple authentication environment per one physical port

- The number of Tx packet - The number of Rx packet - The number of Tx byte

- The number of Rx byte

RADIUS Server 172.16.1.100

Supplicant#1 Supplicant#2 Supplicant#3

0/1 0/2 0/3

0/19 0/22 0/26

VLAN10

VLAN11 VLAN100

VLAN123

Page 45: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

44 / 95

<Configuration target> Use IEEE802.1X authentication in interface0/1-0/3. Authentication database of Interface0/1-0/3 is following -Interface0/1、0/2 : RADIUS Server

-Interface0/3 : Authentication information set locally

AAA Group ID -Interface0/1、0/2 :0

-Interface0/3 :1 Authenticated per Supplicant MAC address

Available users in interface 0/3 are following.

User ID Password Assigned VLAN ID

Supp1 Supp1-pass VLAN123

Supp2 Supp2-pass VLAN100

RADIUS Server IP Address: 172.16.1.100

RADIUS Server is connected to VLAN13. RADIUS Server secret :radius-secret Collect authentication and accounting information in RADIUS server used by interface 0/1 and 0/2

Accounting information and Attribute supported by SBAX2 is following. -Session time :Acct-Session-Time - Tx packet number :Acct-Output-Packets

- Rx packet number :Acct-Input-Packets - Tx byte :Acct-Output-Octets - Rx byte :Acct-Input-Packets

Note

Configure the following attributes in RADISU server in order to assign VLAN ID to users. Please see user guide of RADIUS server for how to configure.

name number Attribute value

Tunnel-Type 64 VLAN (13)

Tunnel-Media-Type 65 802 (6)

Tunnel-Private-Group-ID 81 VLAN ID (coded by ASCII code)

When multiple tunnel attributes are configured by tag, the least available value is assigned to users as

VLAN information.

<Commands> Enable IEEE802.1X authentication

(config)#dot1x use on

Configure port which RADIUS server is connected to (config)#interface 0/26

(config-if)#vlan untag 13 Configure VLAN for RADIUS server

(config)#lan 0 vlan 13 (config)#lan 0 ip address 172.16.1.101/16 3 Configure VLAN which supplicants authenticated by IEEE802.1X are connected to

(config)#interface 0/19 (config-if)#vlan untag 10 (config)#interface 0/20

(config-if)#vlan untag 11 (config)#interface 0/21 (config-if)#vlan untag 100

Page 46: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

45 / 95

(config)#interface 0/22 (config-if)#vlan untag 123

Conifgure IEEE802.1X authentication port (config)#interface 0/1 (config-if)#dot1x aaa 0 (config-if)#dot1x use on

(config)#interface 0/2 (config-if)#dot1x aaa 0 (config-if)#dot1x use on

(config)#interface 0/3 (config-if)#dot1x aaa 1 (config-if)#dot1x use on

Configure AAA group information using RADIUS server. (config)#aaa 0 name radiusAuth (config)#aaa 0 radius service client both

(config)#aaa 0 radius auth source 172.16.1.101 (config)#aaa 0 radius client server-info auth secret radius-secret (config)#aaa 0 radius client server-info auth address 172.16.1.100

(config)#aaa 0 radius client server-info accounting secret radius-secret (config)#aaa 0 radius client server-info accounting address 172.16.1.100

Configure AAA group information using local authentication information (config)# aaa 1 name localAuth (config)# aaa 1 user 0 id Supp1 (config)# aaa 1 user 0 password Supp1-pass

(config)# aaa 1 user 0 supplicant vid 123 (config)# aaa 1 user 1 id Supp2 (config)# aaa 1 user 1 password Supp2-pass

(config)# aaa 1 user 1 supplicant vid 100

Save the configuration

(config)#save

Page 47: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

46 / 95

3.10 Configuring MAC Authentication This section describes how to configure MAC address authentication.

Note

Don’t assign VLAN ID to ports which use MAC address authentication.

Configure AAA group ID correctly for MAC address authentication.

RADIUS Server 172.16.1.100

Supplicant#1 Supplicant#2 Supplicant#3

0/1 0/2 0/3

0/19 0/22 0/26

VLAN10

VLAN11 VLAN100

VLAN123

Page 48: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

47 / 95

<Configuration target> Use MAC address authentication in interface0/1-0/3. Authentication database of Interface0/1-0/3 is following -Interface0/1、0/2 : RADIUS Server

-Interface0/3 : Authentication information set locally

AAA Group ID -Interface0/1、0/2 :0

-Interface0/3 :1 Authenticated per Supplicant MAC address

Available users in interface 0/3 are following.

MAC address Assigned VLAN ID

00:11:11:00:00:01 VLAN123

00:22:22:00:00:02 VLAN100

RADIUS Server IP Address: 172.16.1.100

RADIUS Server is connected to VLAN13. RADIUS Server secret :radius-secret Authentication Protocol: MD5-CHAP

Note

Configure the following attributes in RADISU server in order to assign VLAN ID to users. Please see user guide of RADIUS server for how to configure.

name number Attribute value

Tunnel-Type 64 VLAN (13)

Tunnel-Media-Type 65 802 (6)

Tunnel-Private-Group-ID 81 VLAN ID (coded by ASCII code)

When multiple tunnel attributes are configured by tag, the least available value is assigned to users as VLAN information.

<Commands> Enable MAC address authentication

(config)#macauth use on Configure password for MAC address authentication

(config)#macauth password macauth-pass Configure authentication protocol to MD5-CHAP (config)#macauth type chap_md5

Configure port which RADIUS server is connected to (config)#interface 0/26

(config-if)#vlan untag 13 Configure VLAN for RADIUS server

(config)#lan 0 vlan 13 (config)#lan 0 ip address 172.16.1.101/16 3 Configure VLAN which supplicants authenticated by IEEE802.1X are connected to

(config)#interface 0/19 (config-if)#vlan untag 10 (config)#interface 0/20

(config-if)#vlan untag 11 (config)#interface 0/21 (config-if)#vlan untag 100

Page 49: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

48 / 95

(config)#interface 0/22 (config-if)#vlan untag 123

Conifgure MAC address authentication port (config)#interface 0/1 (config-if)#macauth use on (config-if)#macauth aaa 0

(config)#interface 0/2 (config-if)#macauth use on (config-if)#macauth aaa 0

(config)#interface 0/3 (config-if)#macauth use on (config-if)#macauth aaa 1

Configure AAA group information using RADIUS server. (config)#aaa 0 name radiusAuth (config)#aaa 0 radius service client both

(config)#aaa 0 radius auth source 172.16.1.101 (config)#aaa 0 radius client server-info auth secret radius-secret (config)#aaa 0 radius client server-info auth address 172.16.1.100

(config)# aaa 1 name localAuth (config)# aaa 1 user 0 id 001111000001

(config)# aaa 1 user 0 password macauth-pass (config)# aaa 1 user 0 supplicant vid 123 (config)# aaa 1 user 1 id 002222000002 (config)# aaa 1 user 1 password macauth-pass

(config)# aaa 1 user 1 supplicant vid 100

Save the configuration (config)#save

Page 50: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

49 / 95

3.11 Configuring Port Mirroring This section describes how to configure port mirroring function.

You can monitor the Rx/Tx traffic of source port in the target port by using port mirroring function. This section explains how to configure source port to interfce0/17 and target port to interface 0/26 and

mirror Rx traffic of source port to target port.

<Configuration target> Configure interface0/17 to source port(Rx)

Configure interface0/26 to target port.

<Commands> Configure interface0/17 to mirror port. (config)#interface 0/17

(config-if)#type mirror 0 26 rx

Save the configuration (config)#save

Source Port

Target Port

Analyzer

Page 51: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

50 / 95

3.12 Configuring IP Filtering This section describes how to configure IP filtering which controls packets by combination of IP address

and port number for network security.

<IP Filtering Condition> Packet data flow can be controlled by specifying the following parameter in ACL.

- Source IP Information(IP Address/Address Mask/Port Number)

- Destination IP Information(IP Address/Address Mask/Port Number)

- Protocol

- TOS value、DSCP value of IP packet

<IP Filtering design policy> There are two way for filtering design.

A. Pass the specified packets and reject the others. B. Reject the specified packets and pass the others.

This chapter explains the following examples for A. -Pass only packets to access the specified service. -Pass only packets to the specified server

And explains the following example for B.

-Reject only packets to the specified server -Reject only ping to the specified server.

3.12.1 Configuring IP filter This section describes how to configure IP filter which passes access to Web server and DNS sever and

rejects the other accesses.

<Filtering Design> Pass access to Web server from 192.168.1.0/24 Pass access to DNS server from 192.168.1.0/24 Pass ICMP packets

Reject the other packets

<Commands> Pass TCP packets to port80 of Web Server (config)#acl 0 ip 192.168.1.0/24 any 6 any (config)#acl 0 tcp any 80

(config)#lan 0 ip filter 0 pass acl 0 Pass UDP packets to port53 of DNS server.

(config)#acl 1 ip 192.168.1.0/24 192.168.0.10/32 17 any (config)#acl 0 udp any 53 (config)#lan 0 ip filter 1 pass acl 1

Pass ICMP packets (config)#acl 2 ip any any 1 any (config)#lan 0 ip filter 2 pass acl 2

Reject the other packets

(config)#acl 3 ip any any any

(config)#lan 0 ip filter 3 reject acl 3

Save the configuration

(config)#save

Page 52: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

51 / 95

3.13 Configuring SNMP Agent This section describes how to configure SNMP agent which informs MIB information of SNMP host.

<Configuration target> Use SNMP agent function

• Administrator suzuki • System name SBAX2 • Location 1F

• Agent IP address 192.168.1.1 • SNMP host IP address 192.168.1.100 • community public00

<Commands> Configure SNMPagent information

(config)#snmp agent contact suzuki (config)#snmp agent sysname SBAX2 (config)#snmp agent location 1F

(config)#snmp agent adress 192.168.1.1 Configure SNMPhost information (config)#snmp manager 0 192.168.1.100 public00 off disable

Enable SNMP agent function (config)#snmp service on

Save the configuration

(config)#save

SNMP host 192.168.1.100

lan 0 192.168.1.1

Administrator :Suzuki System name:SBAX2 Agent IP address 192.168.1.1

Inform MIB information against

SNMP request

Page 53: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

52 / 95

This section describes how to configure for SNMPv3 access

<Configuration target> Use SNMP agent function

Administrator suzuki

System name SBAX2 Location 1F

Agent address:192.168.1.1 SNMP host address:192.168.1.100 Host address for trap: 192.168.1.100 User name:user00

Authentication protocol:MD5 Password : auth_password Encryption Protocol : DES

Password: priv_password MIB view: Only system and interfaces groups are enabled Only linkDown and linkUp traps are enabled.

<Commands> Configure SNMP agent infomration (config)#snmp agent contact suzuki

(config)#snmp agent sysname SBAX2 (config)#snmp agent location 1F (config)#snmp agent adress 192.168.1.1

Configure SNMPv3 Information (config)#snmp user 0 name user00 (config)#snmp user 0 address 0 192.168.1.100

(config)#snmp user 0 notification 0 192.168.1.100

Configure Authentication/Encryption protocol

(config)#snmp user 0 auth md5 auth_password (config)#snmp user 0 priv des priv_password

Configure MIB view information (config)#snmp user 0 read view 0 (config)#snmp user 0 notify view 0 (config)#snmp view 0 subtree 0 include system

(config)#snmp view 0 subtree 1 include interfaces (config)#snmp view 0 subtree 2 include linkdown (config)#snmp view 0 subtree 3 include linkup

Enable SNMP Agent function (config)#snmp service on

Savte the configuration (config)#save

Page 54: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

53 / 95

3.14 Configuring System Log

This section describes how to configure system log function which sends system logs to syslog server.

<Configuration Target> Configure the following priority -Priority LOG_ERROR

-Priority LOG_WARNING

-Priority LOG_NOTICE -Priority LOG_INFO

•Syslog server IP address 192.168.1.10

<Command> (config)#syslog server 192.168.1.10

Configure System log (config)#syslog pri error, warm, notice, info

Save the configuration (config)#save

<Restriction> SBAX2 switches provides priority=info and priority=notice messages only

and do not provide any system messages in the case of any critical SBAX2 system state.

Syslog server 192.168.1.10

lan 0 192.168.1.1

Send system logs

Page 55: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

54 / 95

3.15 Configuring Link DownRelay This section describes how to configure Link DownRelay function.

<Configuration Target> Configure interface 0/1- 0/5 to downrelay port for interface 0/19. When interface 0/19 is linkdown, interface 0/1-0/5 is down.

<Command>

(config)#interface 0/19 (config-if)#downrelay port 1-5 (config-if)#exit

Save the configuration (config)#save

Page 56: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

55 / 95

4. Default Settings

4.1 Switch Mode

Item Default Setting

Switching method Cut through switching

Port information

ETHER port 1~18

(Downlink)

19~26

(Uplink)

oob

(MMB connection link)

Data transfer rate 10Gbps 10Gbps 10/100Mbps

(Auto-detect)

Full/half duplex Full-duplex(Fixed) Full-duplex(Fixed) Auto-detect

MDI/MDI-X - -

Flow control Tx:OFF, Rx:ON Tx:ON(Fixed)

Rx:ON(Fixed)

VLAN VID 1 (no tag) -

Protocol VLAN

Predefined protocol IPv4、IPv6

Link down relay Disabled

GVRP Disabled

Link aggregation

Load balancing algorithm Destination MAC address, Source MAC address

Back up port

Port selection scheme Master port preferred

STP information

STP operating mode MSTP enabled for Uplink ports / Disabled for downlinks

LLDP Disabled

Broadcast/Multicast storm

control

Enabled

Threshold value for broadcast storm control: 2Gbps Threshold value for multicast storm control: 2Gbps

Converged Enhance Ethernet Disabled

Output rate control Disabled

Reflective Relay Disabled

IGMP snooping Disabled

MLD snooping Disabled

GMRP Disabled

IEEE802.1X authentication Disabled

Web authentication Disabled

MAC address authentication Disabled

RADIUS client Disabled

TACACS+ client Disabled

LDAP Client Disabled

IP interface In-band = None/OOB = DHCP

Password information

User name admin

Password admin

ACL information None

SNMP information Disabled

DHCP/DNS client Enabled on oob

telnet/SSH auto logoff 5 min

Console auto logoff 8 hours

System log information

System log send Disable

Facility 23(local7)

Page 57: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

56 / 95

Priority error、warn、info

Automatically current time set TIME or SNTP protocol advertised by DHCP server

Schedule information None

Host database information None

Shell function

Character code EUC

4.2 IBP Mode

Item Default Setting

Switching method Cut through switching

Port information

ETHER port 1~18

(Downlink)

19~26

(Uplink)

oob

(MMB connection link)

Data transfer rate 10Gbps 10Gbps 10/100Mbps

(Auto-detect)

Full/half duplex Full-duplex(Fixed) Full-duplex(Fixed) Auto-detect

MDI/MDI-X - -

Flow control Tx:OFF, Rx:ON Tx:ON(Fixed)

Rx:ON(Fixed)

Uplink Set - default -

Port Group default default -

VLAN Port Group - - -

Service LAN - - -

Service VLAN - - -

Link down relay Disabled

Link aggregation

Load balancing algorithm Destination MAC address, Source MAC address

Back up port

Port selection scheme Master port preferred

LLDP Disabled

Broadcast/Multicast storm

control

Enabled Threshold value for broadcast storm control: 2Gbps

Threshold value for multicast storm control: 2Gbps

Converged Enhance Ethernet Disabled

Output rate control Disabled

Reflective Relay Disabled

IGMP snooping Enabled

MLD snooping Enabled

GMRP Disabled

IEEE802.1X authentication Disabled

MAC address authentication Disabled

RADIUS client Disabled

TACACS+ client Disabled

LDAP Client Disabled

IP interface In-band = None/OOB = DHCP

Password information

User name admin

Password admin

ACL information None

SNMP information Disabled

DHCP/DNS client Enabled on oob

telnet/SSH auto logoff 5 min

Console auto logoff 8 hours

Page 58: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

57 / 95

System log information

System log send Disable

Facility 23(local7)

Priority error、warn、info

Automatically current time set TIME or SNTP protocol advertised by DHCP server

Schedule information None

Host database information None

Shell function

Character code EUC

4.3 EHM

Item Default Setting

Switching method Cut through switching

Port information

ETHER port 1~18

(Downlink)

19~26

(Uplink)

oob

(MMB connection link)

Data transfer rate 10Gbps 10Gbps 10/100Mbps

(Auto-detect)

Full/half duplex Full-duplex(Fixed) Full-duplex(Fixed) Auto-detect

MDI/MDI-X - -

Flow control Tx:OFF, Rx:ON Tx:ON(Fixed)

Rx:ON(Fixed)

VLAN VID 1 (no tag) -

Protocol VLAN

Predefined protocol IPv4、IPv6

Link down relay Disabled

GVRP Disabled

Link aggregation

Load balancing algorithm Destination MAC address, Source MAC address

Back up port

Port selection scheme Master port preferred

LLDP Disabled

Broadcast/Multicast storm

control

Enabled Threshold value for broadcast storm control: 2Gbps Threshold value for multicast storm control: 2Gbps

Converged Enhance Ethernet Disabled

Output rate control Disabled

Reflective Relay Disabled

IGMP snooping Disabled

MLD snooping Disabled

GMRP Disabled

IEEE802.1X authentication Disabled

Web authentication Disabled

MAC address authentication Disabled

RADIUS client Disabled

TACACS+ client Disabled

LDAP Client Disabled

IP interface In-band = None/OOB = DHCP

Password information

User name admin

Password admin

ACL information None

SNMP information Disabled

Page 59: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

58 / 95

DHCP/DNS client Enabled on oob

telnet/SSH auto logoff 5 min

Console auto logoff 8 hours

System log information

System log send Disable

Facility 23(local7)

Priority error、warn、info

Automatically current time set TIME or SNTP protocol advertised by DHCP server

Schedule information None

Host database information None

Shell function

Character code EUC

Page 60: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

59 / 95

5. Maximum Values

5.1 Switch Mode

Item Maximum value

Bridge information

of blocks registered(*1) 16416

Of static blocks registered 400

VLAN definition

# of VLANs 1000

Protocol VLAN(*2) 8

Link aggregation

# of member ports 10

# of groups 10

Back up ports

# of groups 13

STP information

# of MSTP instances 16

# of retainable LLDP receive information(*3) 26+378

MAC filters(*4) 64(per switch)

QoS using ACLs(*4) 64(per switch)

IGMP snooping

# of multicast group address registered 400

MLD snooping

# of multicast group address registered 400

GMRP

# of multicast group address registered 400

IEEE802.1X authentication

# of simultaneously authentication clients(*5) 24(per port)

# of simultaneously authentication vlans(*6) 16

Web authentication

# of simultaneously authentication clients(*5) 24(per port)

# of client registrations not required for

authentication

24(per port)

# of simultaneously authentication vlans(*6) 16

MAC address authentication

# of simultaneously authentication clients(*5) 24(per port)

# of client registrations not required for

authentication

24(per port)

# of simultaneously authentication vlans(*6) 16

Port mirroring

Target port(*8) 1 for Tx, 1 for Rx

Converged Enhanced Ethernet

Priority Group 2

PFC 1

ARPs registered 4000

IP interfaces 2

IPv6 interfaces 2

Routing table(IPv4)

# of routes registered 4

# of static routes registered 4

Routing table(IPv6)

# of routes registered

# of RA routes registered 1

Page 61: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

60 / 95

# of static routes registered 4

IP filtering information(*4)

IPv4 max definitions 64(per switch)

IPv6 max definitions 64(per switch)

DSCP rewrite information(*4)

IPv4 max definitions 64(per switch)

IPv6 max definitions 64(per switch)

ACL definitions 700

Host database definitions 100

AAA information

# of groups 10

# of defined authenticated users 1000

# of defined RADIUS servers 4

# of defined TACACS+ servers 4

# of defined LDAP servers 4

SNMP information

# of max. SNMP manager registered 8

RMON

Alarm definition 64

History 50 (per port)

Simultaneous Login

Console 1

Telnet 4

ssh 1 (can not use with sftp)

ftp 1 (can not use with sftp)

sftp 1 (can not use with ftp and ssh

simultaneously)

WWW browser 4

System logging

# of System log records 1024 or more

Max.# of system log servers registered 1

Automated time adjustment

Max. # of SNTP servers registered 1

# of schedules defined 20

Application filtering information

(per application server)

10

*1) Includes own entries of the switch blade, static entries, and entries registered by

authentication or IGMP snooping

*2) The number of protocol filters that can be defined by the user.

*3)Explanation will be described in the future version

*4)Sum of MAC filter, QoS using ACLs, IP filter、IP Precedence/DSCP value rewrite、protocol

VLAN.System maximum value may be less than 64 depending on the setting.

*5)Refers o the combined number of clients throughout all the authentication algorithms. The

actual number may not reach 24 if the MAC address of a client does not fall in the allowed

range.

*6)Explanation will be described in the future version

*8) Target port for Tx and Rx cannot be set to a port at the same time.

*10) Telnet, ssh and WWW browser logins are not allowed during console connection

Page 62: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

61 / 95

5.2 IBP Mode

Item Maximum value

Bridge information

of blocks registered(*1) 16416

Of static blocks registered 400

Uplink Set

Uplink set 18

Port Group

Port Group 18

VLAN Port Group

VLAN Port Group 1000

Service LAN

Service LAN 18

Service VLAN

Service VLAN 1000

Link aggregation

# of member ports 10

# of groups 10

Back up ports

# of groups 4

# of retainable LLDP receive information(*3) 26+378

IGMP snooping

# of multicast group address registered 400

MLD snooping

# of multicast group address registered 400

GMRP

# of multicast group address registered 400

IEEE802.1X authentication

# of simultaneously authentication clients(*5) 24(per port)

# of simultaneously authentication vlans(*6) 16

MAC address authentication

# of simultaneously authentication clients(*5) 24(per port)

# of client registrations not required for

authentication

24(per port)

# of simultaneously authentication vlans(*6) 16

Port mirroring

Target port(*8) 1 for Tx, 1 for Rx

Converged Enhanced Ethernet

Priority Group 2

PFC 1

ARPs registered 4000

IP interfaces 2

IPv6 interfaces 2

Routing table(IPv4)

# of routes registered 4

# of static routes registered 4

Routing table(IPv6)

# of routes registered

# of RA routes registered 1

# of static routes registered 4

IP filtering information(*4)

IPv4 max definitions 64(per switch)

IPv6 max definitions 64(per switch)

DSCP rewrite information(*4)

IPv4 max definitions 64(per switch)

Page 63: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

62 / 95

IPv6 max definitions 64(per switch)

ACL definitions 700

Host database definitions 100

AAA information

# of groups 10

# of defined authenticated users 1000

# of defined RADIUS servers 4

# of defined TACACS+ servers 4

# of defined LDAP servers 4

SNMP information

# of max. SNMP manager registered 8

RMON

Alarm definition 64

History 50 (per port)

Simultaneous Login

Console 1

Telnet 4

ssh 1 (can not use with sftp)

ftp 1 (can not use with sftp)

sftp 1 (can not use with ftp and ssh

simultaneously)

WWW browser 4

System logging

# of System log records 1024 or more

Max.# of system log servers registered 1

Automated time adjustment

Max. # of SNTP servers registered 1

# of schedules defined 20

*1) Includes own entries of the switch blade, static entries, and entries registered by

authentication or IGMP snooping

*2) The number of protocol filters that can be defined by the user.

*3)Explanation will be described in the future version

*4)Sum of MAC filter, QoS using ACLs, IP filter、IP Precedence/DSCP value rewrite、protocol

VLAN.System maximum value may be less than 64 depending on the setting.

*5)Refers o the combined number of clients throughout all the authentication algorithms. The

actual number may not reach 24 if the MAC address of a client does not fall in the allowed

range.

*6)Explanation will be described in the future version

*8) Target port for Tx and Rx cannot be set to a port at the same time.

*10) Telnet, ssh and WWW browser logins are not allowed during console connection

Page 64: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

63 / 95

5.3 EHM

Item Maximum value

Bridge information

of blocks registered(*1) 16416

Of static blocks registered 400

VLAN definition

# of VLANs 1000

Protocol VLAN(*2) 8

Link aggregation

# of member ports 10

# of groups 10

Back up ports

# of groups 13

# of retainable LLDP receive information(*3) 26+378

MAC filters(*4) 64(per switch)

QoS using ACLs(*4) 64(per switch)

IGMP snooping

# of multicast group address registered 400

MLD snooping

# of multicast group address registered 400

GMRP

# of multicast group address registered 400

IEEE802.1X authentication

# of simultaneously authentication clients(*5) 24(per port)

# of simultaneously authentication vlans(*6) 16

Web authentication

# of simultaneously authentication clients(*5) 24(per port)

# of client registrations not required for

authentication

24(per port)

# of simultaneously authentication vlans(*6) 16

MAC address authentication

# of simultaneously authentication clients(*5) 24(per port)

# of client registrations not required for

authentication

24(per port)

# of simultaneously authentication vlans(*6) 16

Port mirroring

Target port(*8) 1 for Tx, 1 for Rx

Converged Enhanced Ethernet

Priority Group 2

PFC 1

ARPs registered 4000

IP interfaces 2

IPv6 interfaces 2

Routing table(IPv4)

# of routes registered 4

# of static routes registered 4

Routing table(IPv6)

# of routes registered

# of RA routes registered 1

# of static routes registered 4

IP filtering information(*4)

IPv4 max definitions 64(per switch)

IPv6 max definitions 64(per switch)

Page 65: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

64 / 95

DSCP rewrite information(*4)

IPv4 max definitions 64(per switch)

IPv6 max definitions 64(per switch)

ACL definitions 700

Host database definitions 100

AAA information

# of groups 10

# of defined authenticated users 1000

# of defined RADIUS servers 4

# of defined TACACS+ servers 4

# of defined LDAP servers 4

SNMP information

# of max. SNMP manager registered 8

RMON

Alarm definition 64

History 50 (per port)

Simultaneous Login

Console 1

Telnet 4

ssh 1 (can not use with sftp)

ftp 1 (can not use with sftp)

sftp 1 (can not use with ftp and ssh

simultaneously)

WWW browser 4

System logging

# of System log records 1024 or more

Max.# of system log servers registered 1

Automated time adjustment

Max. # of SNTP servers registered 1

# of schedules defined 20

Application filtering information

(per application server)

10

*1) Includes own entries of the switch blade, static entries, and entries registered by

authentication or IGMP snooping

*2) The number of protocol filters that can be defined by the user.

*3)Explanation will be described in the future version

*4)Sum of MAC filter, QoS using ACLs, IP filter、IP Precedence/DSCP value rewrite、protocol

VLAN.System maximum value may be less than 64 depending on the setting.

*5)Refers o the combined number of clients throughout all the authentication algorithms. The

actual number may not reach 24 if the MAC address of a client does not fall in the allowed

range.

*6)Explanation will be described in the future version

*8) Target port for Tx and Rx cannot be set to a port at the same time.

*10) Telnet, ssh and WWW browser logins are not allowed during console connection

Page 66: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

65 / 95

6. MIB/Trap List

6.1 Standard MIB

6.1.1 System Group

No Name Object ID MIB ACCESS

1 sysDescr system.1 RO

2 sysObjectID system.2 RO

3 sysUptime system.3 RO

4 sysContact system.4 RW(*)

5 sysName system.5 RW(*)

6 sysLocation system.6 RW(*)

7 sysService system.7 RO

(*)valid until next reset

6.1.2 Interface Group

No Name Object ID MIB ACCESS

1 ifNumber interfaces.1 RO

2 ifTable interfaces.2 -

3 ifEntry ifTable.1 -

4 ifIndex ifEntry.1 RO

5 ifDescr ifEntry.2 RO

6 ifType ifEntry.3 RO

7 ifMtu ifEntry.4 RO

8 ifSpeed ifEntry.5 RW

9 ifPhysAddress ifEntry.6 RO

10 ifAdminStatus ifEntry.7 RO

11 ifOperStatus ifEntry.8 RO

12 ifLastChange ifEntry. ifEntry.9 RO

13 ifInOctets ifEntry.10 RO

14 ifInUcastPkts ifEntry.11 RO

15 ifInNUcastPkts ifEntry.12 RO

16 ifInDiscards ifEntry.13 RO

17 ifInErrors ifEntry.14 RO

18 ifInUnknownProtos ifEntry.15 RO

19 ifOutOctets ifEntry.16 RO

20 ifOutUcastPkts ifEntry.17 RO

21 ifOutNUcastPkts ifEntry.18 RO

22 ifOutDiscards ifEntry.19 RO

23 ifOutErrors ifEntry.20 RO

24 ifOutQLen ifEntry.21 RO

25 ifSpecific ifEntry.22 RO

ifindex interface

1 Inband management interface (lan0)

2 Out of band management interface (oob)

5001 Loopback interface

60xx Link aggregation (6000 + <group number>)

70xx Ether port (7000 + <ether port number>)

Page 67: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

66 / 95

6.1.3 Address Translation Group

No Name Object ID MIB ACCESS

1 atTable at.1 -

2 atEntry atTable.1 -

3 atIfIndex atEntry.1 RO

4 atPhysAddress atEntry.2 RO

5 atNetAddress atEntry.3 RO

6.1.4 IP Group

ip group No Name Object ID MIB ACCESS

1 ipForwarding ip.1 RO

2 ipDefaultTTL ip.2 RO

3 ipInReceives ip.3 RO

4 ipInHdrErrors ip.4 RO

5 ipInAddrErrors ip.5 RO

6 ipForwDatagrams ip.6 RO

7 ipInUnknownProtos ip.7 RO

8 ipInDiscards ip.8 RO

9 ipInDelivers ip.9 RO

10 ipOutRequests ip.10 RO

11 ipOutDiscards ip.11 RO

12 ipOutNoRoutes ip.12 RO

13 ipReasmTimeout ip.13 RO

14 ipReasmReqds ip.14 RO

15 ipReasmOKs ip.15 RO

16 ipReasmFails ip.16 RO

17 ipFragOKs ip.17 RO

18 ipFragFails p.18 RO

19 ipFragCreates ip.19 RO

20 ipRoutingDiscards p.23 RO

Page 68: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

67 / 95

ipAddr group No Name Object ID MIB ACCESS

1 ipAddrTable ip.20 -

2 ipAddrEntry ipAddrTable.1 -

3 ipAdEntAddr ipAddrEntry.1 RO

4 ipAdEntIfIndex ipAddrEntry.2 RO

5 ipAdEntNetMask ipAddrEntry.3 RO

6 ipAdEntBcastAddr ipAddrEntry.4 RO

7 ipAdEntReasmMaxSize ipAddrEntry.5 RO

ipRoute group No Name Object ID MIB ACCESS

1 ipRouteTable ip.21 -

2 ipRouteEntry ipRouteTable.1 -

3 ipRouteDest ipRouteEntry.1 RO

4 ipRouteIfIndex ipRouteEntry.2 RO

5 ipRouteMetric1 ipRouteEntry.3 RO

6 ipRouteMetric2 ipRouteEntry.4 RO

7 ipRouteMetric3 ipRouteEntry.5 RO

8 ipRouteMetric4 ipRouteEntry.6 RO

9 ipRouteNextHop pRouteEntry.7 RO

10 ipRouteType ipRouteEntry.8 RO

11 ipRouteProto ipRouteEntry.9 RO

12 ipRouteAge ipRouteEntry.10 RO

13 ipRouteMask ipRouteEntry.11 RO

14 ipRouteMetric5 ipRouteEntry.12 RO

15 ipRouteInfo ipRouteEntry.13 RO

ipNetToMedia group No Name Object ID MIB ACCESS

1 ipNetToMediaTable ip.22 -

2 ipNetToMediaEntry ipNetToMediaTable.1 -

3 ipNetToMediaIfIndex ipNetToMediaEntry.1 RO

4 ipNetToMediaPhysAddress ipNetToMediaEntry.2 RO

5 ipNetToMediaNetAddress ipNetToMediaEntry.3 RO

6 ipNetToMediaType ipNetToMediaEntry.4 RO

Page 69: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

68 / 95

ipCidrRoute group No Name Object ID MIB ACCESS

1 ipCidrRouteNumber ipForward.3 RO

2 ipCidrRouteTable ipForward.4 -

3 ipCidrRouteEntry ipCidrRouteTable.1 -

4 ipCidrRouteDest ipCidrRouteEntry.1 RO

5 ipCidrRouteMask ipCidrRouteEntry.2 RO

6 ipCidrRouteTos ipCidrRouteEntry.3 RO

7 ipCidrRouteNextHop ipCidrRouteEntry.4 RO

8 ipCidrRouteIfIndex pCidrRouteEntry.5 RO

9 ipCidrRouteType ipCidrRouteEntry.6 RO

10 ipCidrRouteProto ipCidrRouteEntry.7 RO

11 ipCidrRouteAge ipCidrRouteEntry.8 RO

12 ipCidrRouteInfo ipCidrRouteEntry.9 RO

13 ipCidrRouteNextHopAS ipCidrRouteEntry.10 RO

14 ipCidrRouteMetric1 ipCidrRouteEntry.11 RO

15 ipCidrRouteMetric2 ipCidrRouteEntry.12 RO

16 ipCidrRouteMetric3 ipCidrRouteEntry.13 RO

17 ipCidrRouteMetric4 ipCidrRouteEntry.14 RO

18 ipCidrRouteMetric5 ipCidrRouteEntry.15 RO

19 ipCidrRouteStatus ipCidrRouteEntry.16 RO

inetCidrRoute group No Name Object ID MIB ACCESS

1 inetCidrRouteNumber ipForward.6 RO

2 inetCidrRouteTable ipForward.7 -

3 inetCidrRouteEntry inetCidrRouteTable.1 -

4 inetCidrRouteDestType inetCidrRouteEntry.1 -

5 inetCidrRouteDest inetCidrRouteEntry.2 -

6 inetCidrRoutePfxLen inetCidrRouteEntry.3 -

7 inetCidrRoutePolicy inetCidrRouteEntry.4 -

8 inetCidrRouteNextHopType inetCidrRouteEntry.5 -

9 inetCidrRouteNextHop inetCidrRouteEntry.6 -

10 inetCidrRouteIfIndex inetCidrRouteEntry.7 RO

11 inetCidrRouteType inetCidrRouteEntry.8 RO

12 inetCidrRouteProto inetCidrRouteEntry.9 RO

13 inetCidrRouteAge inetCidrRouteEntry.10 RO

14 inetCidrRouteNextHopAS inetCidrRouteEntry.11 RO

15 inetCidrRouteMetric1 inetCidrRouteEntry.12 RO

16 inetCidrRouteMetric2 inetCidrRouteEntry.13 RO

17 inetCidrRouteMetric3 inetCidrRouteEntry.14 RO

18 inetCidrRouteMetric4 inetCidrRouteEntry.15 RO

19 inetCidrRouteMetric5 inetCidrRouteEntry.16 RO

20 inetCidrRouteStatus inetCidrRouteEntry.17 RO

21 inetCidrRouteDiscards ipForward.8 RO

Page 70: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

69 / 95

ipv6 group No Name Object ID MIB ACCESS

1 ipv6IpForwarding ip.25 RO

2 ipv6IpDefaultHopLimit ip.26 RO

Ipv4Interface group No Name Object ID MIB ACCESS

1 ipv4InterfaceTableLastChange ip.27 RO

2 ipv4InterfaceTable ip.28 -

3 ipv4InterfaceEntry ipv4InterfaceTable.1 -

4 ipv4InterfaceIfIndex ipv4InterfaceEntry.1 -

5 ipv4InterfaceReasmMaxSize ipv4InterfaceEntry.2 RO

6 ipv4InterfaceEnableStatus ipv4InterfaceEntry.3 RO

7 ipv4InterfaceRetransmitTime ipv4InterfaceEntry.4 RO

Ipv6Interface group No Name Object ID MIB ACCESS

1 ipv6InterfaceTableLastChange ip.29 RO

2 ipv6InterfaceTable ip.30 -

3 ipv6InterfaceEntry ipv6InterfaceTable.1 -

4 ipv6InterfaceIfIndex ipv6InterfaceEntry.1 -

5 ipv6InterfaceReasmMaxSize ipv6InterfaceEntry.2 RO

6 ipv6InterfaceIdentifier ipv6InterfaceEntry.3 RO

7 ipv6InterfaceEnableStatus ipv6InterfaceEntry.5 RO

8 ipv6InterfaceReachableTime ipv6InterfaceEntry.6 RO

9 ipv6InterfaceRetransmitTime ipv6InterfaceEntry.7 RO

10 ipv6InterfaceForwarding ipv6InterfaceEntry.8 RO

ipSystemStats group No Name Object ID MIB ACCESS

1 ipSystemStatsTable ipTrafficStats.1 -

2 ipSystemStatsEntry ipSystemStatsTable.1 -

3 ipSystemStatsIPVersion ipSystemStatsEntry.1 -

4 ipSystemStatsInReceives ipSystemStatsEntry.3 -

5 ipSystemStatsInHdrErrors ipSystemStatsEntry.7 RO

6 ipSystemStatsInUnknownProtos ipSystemStatsEntry.10 RO

7 ipSystemStatsInTruncatedPkts ipSystemStatsEntry.11 RO

8 ipSystemStatsInForwDatagrams ipSystemStatsEntry.12 RO

9 ipSystemStatsReasmReqds ipSystemStatsEntry.14 RO

10 ipSystemStatsReasmOKs ipSystemStatsEntry.15 RO

11 ipSystemStatsReasmFails ipSystemStatsEntry.16 RO

12 ipSystemStatsInDelivers ipSystemStatsEntry.18 RO

13 ipSystemStatsOutRequests ipSystemStatsEntry.20 RO

14 ipSystemStatsOutNoRoutes ipSystemStatsEntry.22 RO

15 ipSystemStatsOutForwDatagrams ipSystemStatsEntry.23 RO

16 ipSystemStatsOutDiscards ipSystemStatsEntry.25 RO

17 ipSystemStatsOutFragReqds ipSystemStatsEntry.26 RO

18 ipSystemStatsOutFragOKs ipSystemStatsEntry.27 RO

Page 71: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

70 / 95

19 ipSystemStatsOutFragFails ipSystemStatsEntry.28 RO

20 ipSystemStatsOutFragCreates ipSystemStatsEntry.28 RO

21 ipSystemStatsOutTransmits ipSystemStatsEntry.30 RO

22 ipSystemStatsDiscontinuityTime ipSystemStatsEntry.46 RO

23 ipSystemStatsRefreshRate ipSystemStatsEntry.47 RO

ipAddressPrefix group No Name Object ID MIB ACCESS

1 ipAddressPrefixTable ip.32 -

2 ipAddressPrefixEntry ipAddressPrefixTable.1 -

3 ipAddressPrefixIfIndex ipAddressPrefixEntry.1 -

4 ipAddressPrefixType ipAddressPrefixEntry.2 -

5 ipAddressPrefixPrefix ipAddressPrefixEntry.3 -

6 ipAddressPrefixLength ipAddressPrefixEntry.4 -

7 ipAddressPrefixOrigin ipAddressPrefixEntry.5 RO

8 ipAddressPrefixOnLinkFlag ipAddressPrefixEntry.6 RO

9 ipAddressPrefixAutonomousFlag ipAddressPrefixEntry.7 RO

10 ipAddressPrefixAdvPreferredLifetime ipAddressPrefixEntry.8 RO

11 ipAddressPrefixAdvValidLifetime ipAddressPrefixEntry.9 RO

ipAddress group No Name Object ID MIB ACCESS

1 ipAddressTable ip.34 -

2 ipAddressEntry ipAddressTable.1 -

3 ipAddressAddrType ipAddressEntry.1 -

4 ipAddressAddr ipAddressEntry.2 -

5 ipAddressIfIndex ipAddressEntry.3 -

6 ipAddressType ipAddressEntry.4 -

7 ipAddressPrefix ipAddressEntry.5 RO

8 ipAddressOrigin ipAddressEntry.6 RO

9 ipAddressStatus ipAddressEntry.7 RO

10 ipAddressCreated ipAddressEntry.8 RO

11 ipAddressLastChanged ipAddressEntry.9 RO

12 ipAddressRowStatus ipAddressEntry.10 RO

13 ipAddressStorageType ipAddressEntry.11 RO

Page 72: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

71 / 95

ipNetToPhysical group

No Name Object ID MIB ACCESS

1 ipNetToPhysicalTable ip.35 -

2 ipNetToPhysicalEntry ipNetToPhysicalTable.1 -

3 ipNetToPhysicalIfIndex ipNetToPhysicalEntry.1 -

4 ipNetToPhysicalNetAddressType ipNetToPhysicalEntry.2 -

5 ipNetToPhysicalNetAddress ipNetToPhysicalEntry.3 -

6 ipNetToPhysicalPhysAddress ipNetToPhysicalEntry.4 RO

7 ipNetToPhysicalLastUpdated ipNetToPhysicalEntry.5 RO

8 ipNetToPhysicalType ipNetToPhysicalEntry.6 RO

9 ipNetToPhysicalState ipNetToPhysicalEntry.7 RO

10 ipNetToPhysicalRowStatus ipNetToPhysicalEntry.8 RO

ipv6RouterAdvert group No Name Object ID MIB ACCESS

1 ipv6RouterAdvertTable ip.39 -

2 ipv6RouterAdvertEntry ipv6RouterAdvertTable.1 -

3 ipv6RouterAdvertIfIndex ipv6RouterAdvertEntry.1 -

4 ipv6RouterAdvertSendAdverts ipv6RouterAdvertEntry.2 RO

5 ipv6RouterAdvertMaxInterval ipv6RouterAdvertEntry.3 RO

6 ipv6RouterAdvertMinInterval ipv6RouterAdvertEntry.4 RO

7 ipv6RouterAdvertManagedFlag ipv6RouterAdvertEntry.5 RO

8 ipv6RouterAdvertOtherConfigFlag ipv6RouterAdvertEntry.6 RO

9 ipv6RouterAdvertLinkMTU ipv6RouterAdvertEntry.7 RO

10 ipv6RouterAdvertReachableTime ipv6RouterAdvertEntry.8 RO

11 ipv6RouterAdvertRetransmitTime ipv6RouterAdvertEntry.9 RO

12 ipv6RouterAdvertCurHopLimit ipv6RouterAdvertEntry.10 RO

13 ipv6RouterAdvertDefaultLifetime ipv6RouterAdvertEntry.11 RO

14 ipv6RouterAdvertRowStatus ipv6RouterAdvertEntry.12 RO

6.1.5 IGMP Group

Icmp group No Name Object ID MIB ACCESS

1 icmpInMsgs icmp.1 RO

2 icmpInErrors icmp.2 RO

3 icmpInDestUnreachs icmp.3 RO

4 icmpInTimeExcds icmp.4 RO

5 icmpInParmProbs icmp.5 RO

6 icmpInSrcQuenchs icmp.6 RO

7 icmpInRedirects icmp.7 RO

8 icmpInEchos icmp.8 RO

9 icmpInEchoReps icmp.9 RO

10 icmpInTimestamps icmp.10 RO

11 icmpInTimestampReps icmp.11 RO

12 icmpInAddrMasks icmp.12 RO

13 icmpInAddrMaskReps icmp.13 RO

Page 73: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

72 / 95

14 icmpOutMsgs icmp.14 RO

15 icmpOutErrors icmp.15 RO

16 icmpOutDestUnreachs icmp.16 RO

17 icmpOutTimeExcds icmp.17 RO

18 icmpOutParmProbs icmp.18 RO

19 icmpOutSrcQuenchs icmp.19 RO

20 icmpOutRedirects icmp.20 RO

21 icmpOutEchos icmp.21 RO

22 icmpOutEchoReps icmp.22 RO

23 icmpOutTimestamps icmp.23 RO

24 icmpOutTimestampReps icmp.24 RO

25 icmpOutAddrMasks icmp.25 RO

26 icmpOutAddrMaskReps icmp.26 RO

icmpStat group No Name Object ID MIB ACCESS

1 icmpStatsTable icmp.29 -

2 icmpStatsEntry icmpStatsTable.1 -

3 icmpStatsIPVersion icmpStatsEntry.1 -

4 icmpStatsInMsgs icmpStatsEntry.2 RO

5 icmpStatsInErrors icmpStatsEntry.3 RO

6 icmpStatsOutMsgs icmpStatsEntry.4 RO

7 icmpStatsOutErrors icmpStatsEntry.5 RO

icmpMsgStats group No Name Object ID MIB ACCESS

1 icmpMsgStatsTable icmp.30 -

2 icmpMsgStatsEntry icmpMsgStatsTable.1 -

3 icmpMsgStatsIPVersion icmpMsgStatsEntry.1 -

4 icmpMsgStatsType icmpMsgStatsEntry.2 -

5 icmpMsgStatsInPkts icmpMsgStatsEntry.3 RO

6 icmpMsgStatsOutPkts icmpMsgStatsEntry.4 RO

Page 74: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

73 / 95

6.1.6 TCP Group

Tcp group No Name Object ID MIB ACCESS

1 tcpRtoAlgorithm tcp.1 RO

2 tcpRtoMin tcp.2 RO

3 tcpRtoMax tcp.3 RO

4 tcpMaxConn tcp.4 RO

5 tcpActiveOpens tcp.5 RO

6 tcpPassiveOpens tcp.6 RO

7 tcpAttemptFails tcp.7 RO

8 tcpEstabResets tcp.8 RO

9 tcpCurrEstab tcp.9 RO

10 tcpInSegs tcp.10 RO

11 tcpOutSegs tcp.11 RO

12 tcpRetransSegs tcp.12 RO

13 tcpInErrs tcp.14 RO

14 tcpOutRsts tcp.15 RO

TcpConn group No Name Object ID MIB ACCESS

1 tcpConnTable tcp.13 -

2 tcpConnEntry tcpConnTable.1 -

3 tcpConnState tcpConnEntry.1 RO

4 tcpConnLocalAddress tcpConnEntry.2 RO

5 tcpConnLocalAddress tcpConnEntry.3 RO

6 tcpConnRemAddress tcpConnEntry.4 RO

7 tcpConnRemPort tcpConnEntry.5 RO

TcpConnection group No Name Object ID MIB ACCESS

1 tcpConnectionTable tcp.19 -

2 tcpConnectionEntry tcpConnectionTable.1 -

3 tcpConnectionLocalAddressType tcpConnectionEntry.1 -

4 tcpConnectionLocalAddress tcpConnectionEntry.2 -

5 tcpConnectionLocalPort tcpConnectionEntry.3 -

6 tcpConnectionRemAddressType tcpConnectionEntry.4 -

7 tcpConnectionRemAddress tcpConnectionEntry.5 -

8 tcpConnectionRemPort tcpConnectionEntry.6 -

9 tcpConnectionState tcpConnectionEntry.7 RO

10 tcpConnectionProcess tcpConnectionEntry.8 RO

Page 75: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

74 / 95

Tcp Listener group No Name Object ID MIB ACCESS

1 tcpListenerTable tcp.20 -

2 tcpListenerEntry tcpListenerTable.1 -

3 tcpListenerLocalAddressType tcpListenerEntry.1 -

4 tcpListenerLocalAddress tcpListenerEntry.2 -

5 tcpListenerLocalPort tcpListenerEntry.3 -

6 tcpListenerProcess tcpListenerEntry.4 RO

6.1.7 UDP Group

udp group No Name Object ID MIB ACCESS

1 udpInDatagrams udp.1 RO

2 udpNoPorts udp.2 RO

3 udpInErrors udp.3 RO

4 udpOutDatagrams udp.4 RO

udpLisfener group No Name Object ID MIB ACCESS

1 udpTable udp.5 -

2 udpEntry udpTable.1 -

3 udpLocalAddress udpEntry.1 RO

4 udpLocalPort udpEntry.2 RO

udpEndpoint group No Name Object ID MIB ACCESS

1 udpEndpointTable udp.7 -

2 udpEndpointEntry udpEndpointTable.1 -

3 udpEndpointLocalAddressType udpEndpointEntry.1 -

4 udpEndpointLocalAddress udpEndpointEntry.2 -

5 udpEndpointLocalPort udpEndpointEntry.3 -

6 udpEndpointRemoteAddressType udpEndpointEntry.4 -

7 udpEndpointRemoteAddress udpEndpointEntry.5 -

8 udpEndpointRemotePort udpEndpointEntry.6 -

9 udpEndpointInstance udpEndpointEntry.7 -

10 udpEndpointProcess udpEndpointEntry.8 RO

Page 76: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

75 / 95

6.1.8 Dot3 Group

dot3Sats group No Name Object ID MIB ACCESS

1 dot3StatsTable dot3.2 -

2 dot3StatsEntry dot3StatsTable.1 -

3 dot3StatsIndex dot3StatsEntry.1 RO

4 dot3StatsAlignmentErrors dot3StatsEntry.2 RO

5 dot3StatsFCSErrors dot3StatsEntry.3 RO

6 dot3StatsSingleCollisionFrames dot3StatsEntry.4 RO

7 dot3StatsMultipleCollisionFrames dot3StatsEntry.5 RO

8 dot3StatsSQETestErrors dot3StatsEntry.6 RO

9 dot3StatsDeferredTransmissions dot3StatsEntry.7 RO

10 dot3StatsLateCollisions dot3StatsEntry.8 RO

11 dot3StatsExcessiveCollisions dot3StatsEntry.9 RO

12 dot3StatsInternalMacTransmitErrors dot3StatsEntry.10 RO

13 dot3StatsCarrierSenseErrors dot3StatsEntry.11 RO

14 dot3StatsFrameTooLongs dot3StatsEntry.13 RO

15 dot3StatsInternalMacReceiveErrors dot3StatsEntry.16 RO

16 dot3StatsEtherChipSet dot3StatsEntry.17 RO

17 dot3StatsSymbolErrors dot3StatsEntry.18 RO

18 dot3StatsDuplexStatus dot3StatsEntry.19 RO

19 dot3StatsRateControlAbility dot3StatsEntry.20 RO

20 dot3StatsRateControlStatus dot3StatsEntry.21 RO

dot3Control group No Name Object ID MIB ACCESS

1 dot3ControlTable dot3.9 -

2 dot3ControlEntry dot3ControlTable.1 -

3 dot3ControlFunctionsSupported dot3ControlEntry.1 RO

4 dot3ControlInUnknownOpcodes dot3ControlEntry.2 RO

dot3Pause group No Name Object ID MIB ACCESS

1 dot3PauseTable dot3.10 -

2 dot3PauseEntry dot3PauseTable.1 -

3 dot3PauseAdminMode dot3PauseEntry.1 RO

4 dot3PauseOperMode dot3PauseEntry.2 RO

5 dot3InPauseFrames dot3PauseEntry.3 RO

6 dot3OutPauseFrames dot3PauseEntry.4 RO

Page 77: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

76 / 95

6.1.9 SNMP Group

No Name Object ID MIB ACCESS

1 snmpInPkts snmp.1 RO

2 snmpOutPkts snmp.2 RO

3 snmpInBadVersions snmp.3 RO

4 snmpInBadCommunityNames snmp.4 RO

5 snmpInBadCommunityUses snmp.5 RO

6 snmpInASNParseErrs snmp.6 RO

7 snmpInTooBigs snmp.8 RO

8 snmpInNoSuchNames snmp.9 RO

9 snmpInBadValues snmp.10 RO

10 snmpInReadOnlys snmp.11 RO

11 snmpInGenErrs snmp.12 RO

12 snmpInTotalReqVars snmp.13 RO

13 snmpInTotalSetVars snmp.14 RO

14 snmpInGetRequests snmp.15 RO

15 snmpInGetNexts snmp.16 RO

16 snmpInSetRequests snmp.17 RO

17 snmpInGetResponses snmp.18 RO

18 snmpInTraps snmp.19 RO

19 snmpOutTooBigs snmp.20 RO

20 snmpOutNoSuchNames snmp.21 RO

21 snmpOutBadValues snmp.22 RO

22 snmpOutGenErrs snmp.24 RO

23 snmpOutGetRequests snmp.25 RO

24 snmpOutGetNexts snmp.26 RO

25 snmpOutSetRequests snmp.27 RO

26 snmpOutGetResponses snmp.28 RO

27 snmpOutTraps snmp.29 RO

28 snmpEnableAuthenTraps snmp.30 RO

6.1.10 rmon Group

rmonEthernetStatistics group No Name Object ID MIB ACCESS

1 etherStatsTable statistics.1 -

2 etherStatsEntry etherStatsTable.1 -

3 etherStatsIndex etherStatsEntry.1 RO

4 etherStatsDataSource etherStatsEntry.2 RO

5 etherStatsDropEvents etherStatsEntry.3 RO

6 etherStatsOctets etherStatsEntry.4 RO

7 etherStatsPkts etherStatsEntry.5 RO

8 etherStatsBroadcastPkts etherStatsEntry.6 RO

9 etherStatsMulticastPkts etherStatsEntry.7 RO

10 etherStatsCRCAlignErrors etherStatsEntry.8 RO

11 etherStatsUndersizePkts etherStatsEntry.9 RO

12 etherStatsOversizePkts etherStatsEntry.10 RO

13 etherStatsFragments etherStatsEntry.11 RO

14 etherStatsJabbers etherStatsEntry.12 RO

15 etherStatsCollisions etherStatsEntry.13 RO

16 etherStatsPkts64Octets etherStatsEntry.14 RO

Page 78: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

77 / 95

17 etherStatsPkts65to127Octets etherStatsEntry.15 RO

18 etherStatsPkts128to255Octets etherStatsEntry.16 RO

19 etherStatsPkts256to511Octets etherStatsEntry.17 RO

20 etherStatsPkts512to1023Octets etherStatsEntry.18 RO

21 etherStatsPkts1024to1518Octets etherStatsEntry.19 RO

22 etherStatsOwner etherStatsEntry.20 RO

23 etherStatsStatus etherStatsEntry.21 RO

rmonHistoryControl group No Name Object ID MIB ACCESS

1 historyControlTable history.1 -

2 historyControlEntry historyControlTable.1 -

3 historyControlIndex historyControlEntry.1 RO

4 historyControlDataSource historyControlEntry.2 RO

5 historyControlBucketsRequested historyControlEntry.3 RO

6 historyControlBucketsGranted historyControlEntry.4 RO

7 historyControlInterval historyControlEntry.5 RO

8 historyControlOwner historyControlEntry.6 RO

9 historyControlStatus historyControlEntry.7 RO

rmonEthernetHistory group No Name Object ID MIB ACCESS

1 etherHistoryTable history.2 -

2 etherHistoryEntry etherHistoryTable.1 -

3 etherHistoryIndex etherHistoryEntry.1 RO

4 etherHistorySampleIndex etherHistoryEntry.2 RO

5 etherHistoryIntervalStart etherHistoryEntry.3 RO

6 etherHistoryDropEvents etherHistoryEntry.4 RO

7 etherHistoryOctets etherHistoryEntry.5 RO

8 etherHistoryPkts etherHistoryEntry.6 RO

9 etherHistoryBroadcastPkts etherHistoryEntry.7 RO

10 etherHistoryMulticastPkts etherHistoryEntry.8 RO

11 etherHistoryCRCAlignErrors etherHistoryEntry.9 RO

12 etherHistoryUndersizePkts etherHistoryEntry.10 RO

13 etherHistoryOversizePkts etherHistoryEntry.11 RO

14 etherHistoryFragments etherHistoryEntry.12 RO

15 etherHistoryJabbers etherHistoryEntry.13 RO

16 etherHistoryCollisions etherHistoryEntry.14 RO

17 etherHistoryUtilization etherHistoryEntry.15 RO

Page 79: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

78 / 95

rmonAlarm group

No Name Object ID MIB ACCESS

1 alarmTable alarm.1 -

2 alarmEntry alarmTable.1 -

3 alarmIndex alarmEntry.1 RO

4 alarmInterval alarmEntry.2 RO

5 alarmVariable alarmEntry.3 RO

6 alarmSampleType alarmEntry.4 RO

7 alarmValue alarmEntry.5 RO

8 alarmStartupAlarm alarmEntry.6 RO

9 alarmRisingThreshold alarmEntry.7 RO

10 alarmFallingThreshold alarmEntry.8 RO

11 alarmRisingEventIndex alarmEntry.9 RO

12 alarmFallingEventIndex alarmEntry.10 RO

13 alarmOwner alarmEntry.11 RO

14 alarmStatus alarmEntry.12 RO

rmonEvent group

No Name Object ID MIB ACCESS

1 eventTable event.1 -

2 eventEntry eventTable.1 -

3 eventIndex eventEntry.1 RO

4 eventDescription eventEntry.2 RO

5 eventType eventEntry.3 RO

6 eventCommunity eventEntry.4 RO

7 eventLastTimeSent eventEntry.5 RO

8 eventOwner eventEntry.6 RO

9 eventStatus eventEntry.7 RO

10 logTable event.2 -

11 logEntry logTable.1 -

12 logEventIndex logEntry.1 RO

13 logIndex logEntry.2 RO

14 logTime logEntry.3 RO

15 logDescription logEntry.4 RO

Page 80: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

79 / 95

6.1.11 Dot1dBridge Group

dot1dBase group No Name Object ID MIB ACCESS

1 dot1dBaseBridgeAddress dot1dBase.1 RO

2 dot1dBaseNumPorts dot1dBase.2 RO

3 dot1dBaseType dot1dBase.3 RO

4 dot1dBasePortTable dot1dBase.4 -

5 dot1dBasePortEntry dot1dBasePortTable.1 -

6 dot1dBasePort dot1dBasePortEntry.1 RO

7 dot1dBasePortIfIndex dot1dBasePortEntry.2 RO

8 dot1dBasePortCircuit dot1dBasePortEntry.3 RO

9 dot1dBasePortDelayExceededDiscards dot1dBasePortEntry.4 RO

10 dot1dBasePortMtuExceededDiscards dot1dBasePortEntry.5 RO

dot1dStp group No Name Object ID MIB ACCESS

1 dot1dStpProtocolSpecification dot1dStp.1 RO

2 dot1dStpPriority dot1dStp.2 RO

3 dot1dStpTimeSinceTopologyChange dot1dStp.3 RO

4 dot1dStpTopChanges dot1dStp.4 RO

5 dot1dStpDesignatedRoot dot1dStp.5 RO

6 dot1dStpRootCost dot1dStp.6 RO

7 dot1dStpRootPort dot1dStp.7 RO

8 dot1dStpMaxAge dot1dStp.8 RO

9 dot1dStpHelloTime dot1dStp.9 RO

10 dot1dStpHoldTime dot1dStp.10 RO

11 dot1dStpForwardDelay dot1dStp.11 RO

12 dot1dStpBridgeMaxAge dot1dStp.12 RO

13 dot1dStpBridgeHelloTime dot1dStp.13 RO

14 dot1dStpBridgeForwardDelay dot1dStp.14 RO

15 dot1dStpPortTable dot1dStp.15 -

16 dot1dStpPortEntry dot1dStpPortTable.1 -

17 dot1dStpPort dot1dStpPortEntry.1 RO

18 dot1dStpPortPriority dot1dStpPortEntry.2 RO

19 dot1dStpPortState dot1dStpPortEntry.3 RO

20 dot1dStpPortEnable dot1dStpPortEntry.4 RO

21 dot1dStpPortPathCost dot1dStpPortEntry.5 RO

22 dot1dStpPortDesignatedRoot dot1dStpPortEntry.6 RO

23 dot1dStpPortDesignatedCost dot1dStpPortEntry.7 RO

24 dot1dStpPortDesignatedBridge dot1dStpPortEntry.8 RO

25 dot1dStpPortDesignatedPort dot1dStpPortEntry.9 RO

26 dot1dStpPortForwardTransitions dot1dStpPortEntry.10 RO

Page 81: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

80 / 95

dot1dTp group No Name Object ID MIB ACCESS

1 dot1dTpLearnedEntryDiscards dot1dTp.1 RO

2 dot1dTpAgingTime dot1dTp.2 RO

3 dot1dTpFdbTable dot1dTp.3 -

4 dot1dTpFdbEntry dot1dTpFdbTable.1 -

5 dot1dTpFdbAddress dot1dTpFdbEntry.1 RO

6 dot1dTpFdbPort dot1dTpFdbEntry.2 RO

7 dot1dTpFdbStatus dot1dTpFdbEntry.3 RO

8 dot1dTpPortTable dot1dTp.4 -

9 dot1dTpPortEntry dot1dTpPortTable.1 -

10 dot1dTpPort dot1dTpPortEntry.1 RO

11 dot1dTpPortMaxInfo dot1dTpPortEntry.2 RO

12 dot1dTpPortInFrames dot1dTpPortEntry.3 RO

13 dot1dTpPortOutFrames dot1dTpPortEntry.4 RO

14 dot1dTpPortInDiscards dot1dTpPortEntry.5 RO

dot1dExtBase group

No Name Object ID MIB ACCESS

1 dot1dDeviceCapabilities dot1dExtBase.1 RO

2 dot1dTrafficClassesEnabled dot1dExtBase.2 RO

3 dot1dGmrpStatus dot1dExtBase.3 RO

4 dot1dPortCapabilitiesTable dot1dExtBase.4 -

5 dot1dPortCapabilitiesEntry dot1dPortCapabilitiesTable.1 -

6 dot1dPortCapabilities dot1dPortCapabilitiesEntry.1 RO

dot1dPriority group No Name Object ID MIB ACCESS

1 dot1dPortPriorityTable dot1dPriority.1 -

2 dot1dPortPriorityEntry dot1dPortPriorityTable.1 -

3 dot1dPortDefaultUserPriority dot1dPortPriorityEntry.1 RO

4 dot1dPortNumTrafficClasses dot1dPortPriorityEntry.2 RO

5 dot1dTrafficClassTable dot1dPriority.3 -

6 dot1dTrafficClassEntry dot1dTrafficClassTable.1 -

7 dot1dTrafficClassPriority dot1dTrafficClassEntry.1 -

8 dot1dTrafficClass dot1dTrafficClassEntry.2 RO

Page 82: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

81 / 95

6.1.12 qBridgeMIB Group

dot1qBase group No Name Object ID MIB ACCESS

1 dot1qVlanVersionNumber dot1qBase.1 RO

2 dot1qMaxVlanId dot1qBase.2 RO

3 dot1qMaxSupportedVlans dot1qBase.3 RO

4 dot1qNumVlans dot1qBase.4 RO

5 dot1qGvrpStatus dot1qBase.5 RO

dot1qVlan group No Name Object ID MIB ACCESS

1 dot1qVlanNumDeletes dot1qVlan.1 RO

2 dot1qVlanCurrentTable dot1qVlan.2 -

3 dot1qVlanCurrentEntry dot1qVlanCurrentTable.1 -

4 dot1qVlanTimeMark dot1qVlanCurrentEntry.1 -

5 dot1qVlanIndex dot1qVlanCurrentEntry.2 -

6 dot1qVlanCurrentEgressPorts dot1qVlanCurrentEntry.4 RO

7 dot1qVlanCurrentUntaggedPorts dot1qVlanCurrentEntry.5 RO

8 dot1qVlanStatus dot1qVlanCurrentEntry.6 RO

9 dot1qVlanStaticTable dot1qVlan.3 -

10 dot1qVlanStaticEntry dot1qVlanStaticTable.1 -

11 dot1qVlanStaticName dot1qVlanStaticEntry.1 RO

12 dot1qVlanStaticEgressPorts dot1qVlanStaticEntry.2 RO

13 dot1qVlanForbiddenEgressPorts dot1qVlanStaticEntry.3 RO

14 dot1qVlanStaticUntaggedPorts dot1qVlanStaticEntry.4 RO

15 dot1qVlanStaticRowStatus dot1qVlanStaticEntry.5

16 dot1qNextFreeLocalVlanIndex dot1qVlan.4

17 dot1qPortVlanTable dot1qVlan.5 -

18 dot1qPortVlanEntry dot1qPortVlanTable.1 -

19 dot1qPvid dot1qPortVlanEntry.1 RO

20 dot1qPortAcceptableFrameTypes dot1qPortVlanEntry.2 RO

21 dot1qPortIngressFiltering dot1qPortVlanEntry.3 RO

22 dot1qPortGvrpStatus dot1qPortVlanEntry.4 RO

Page 83: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

82 / 95

6.1.13 ifMIB Group

ifMIB group

No Name Object ID MIB ACCESS

1 ifXTable ifMIBObjects.1 -

2 ifXEntry ifXTable.1 -

3 ifName ifXEntry.1 RO

4 ifInMulticastPkts ifXEntry.2 RO

5 ifInBroadcastPkts ifXEntry.3 RO

6 ifOutMulticastPkts ifXEntry.4 RO

7 ifOutBroadcastPkts ifXEntry.5 RO

8 ifHCInOctets ifXEntry.6 RO

9 ifHCInUcastPkts ifXEntry.7 RO

10 ifHCInMulticastPkts ifXEntry.8 RO

11 ifHCInBroadcastPkts ifXEntry.9 RO

12 ifHCOutOctets ifXEntry.10 RO

13 ifHCOutUcastPkts ifXEntry.11 RO

14 ifHCOutMulticastPkts ifXEntry.12 RO

15 ifHCOutBroadcastPkts ifXEntry.13 RO

16 ifLinkUpDownTrapEnable ifXEntry.14 RO

17 ifHighSpeed ifXEntry.15 RO

18 ifPromiscuousMode ifXEntry.16 RO

19 ifConnectorPresent ifXEntry.17 RO

20 ifAlias ifXEntry.18 RO

21 ifCounterDiscontinuityTime ifXEntry.19 RO

ifStack group

No Name Object ID MIB ACCESS

1 ifStackTable ifMIBObjects.2 -

2 ifStackEntry ifStackTable.1 -

3 ifStackHigherLayer ifStackEntry.1 -

4 ifStackLowerLayer ifStackEntry.2 -

5 ifStackStatus ifStackEntry.3 RO

ifMIB group

No Name Object ID MIB ACCESS

1 ifTableLastChange ifMIBObjects.5 RO

2 ifStackLastChange ifMIBObjects.6 RO

Page 84: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

83 / 95

6.1.14 radiusMIB Group

radiusAuthClient group

No Name Object ID MIB

ACCESS

1 radiusAuthClientInvalidServerAddresses radiusAuthClient.1 RO

2 radiusAuthClientIdentifier radiusAuthClient.2 RO

3 radiusAuthServerTable radiusAuthClient.3 -

4 radiusAuthServerEntry radiusAuthServerTable.1 -

5 radiusAuthServerIndex radiusAuthServerEntry.1 -

6 radiusAuthServerAddress radiusAuthServerEntry.1 RO

7 radiusAuthClientServerPortNumber radiusAuthServerEntry.2 RO

8 radiusAuthClientRoundTripTime radiusAuthServerEntry.3 RO

9 radiusAuthClientAccessRequests radiusAuthServerEntry.4 RO

10 radiusAuthClientAccessRetransmissions radiusAuthServerEntry.5 RO

11 radiusAuthClientAccessAccepts radiusAuthServerEntry.6 RO

12 radiusAuthClientAccessRejects radiusAuthServerEntry.7 RO

13 radiusAuthClientAccessChallenges radiusAuthServerEntry.8 RO

14 radiusAuthClientMalformedAccessResponses radiusAuthServerEntry.9 RO

15 radiusAuthClientBadAuthenticators radiusAuthServerEntry.10 RO

16 radiusAuthClientPendingRequests radiusAuthServerEntry.11 RO

17 radiusAuthClientTimeouts radiusAuthServerEntry.12 RO

18 radiusAuthClientUnknownTypes radiusAuthServerEntry.13 RO

19 radiusAuthClientPacketsDropped radiusAuthServerEntry.14 RO

radiusAccClient group

No Name Object ID MIB ACCESS

1 radiusAccClientInvalidServerAddresse

s

radiusAccClient.1 RO

2 radiusAccClientIdentifier radiusAccClient.2 RO

3 radiusAccServerTable radiusAccClient.3 -

4 radiusAccServerEntry radiusAccServerTable.1 -

5 radiusAccServerIndex radiusAccServerEntry.1 -

6 radiusAccServerAddress radiusAccServerEntry.2 RO

7 radiusAccClientServerPortNumber radiusAccServerEntry.3 RO

8 radiusAccClientRoundTripTime radiusAccServerEntry.4 RO

9 radiusAccClientRequests radiusAccServerEntry.5 RO

10 radiusAccClientRetransmissions radiusAccServerEntry.6 RO

11 radiusAccClientResponses radiusAccServerEntry.7 RO

12 radiusAccClientMalformedResponses radiusAccServerEntry.8 RO

13 radiusAccClientBadAuthenticators radiusAccServerEntry.9 RO

14 radiusAccClientPendingRequests radiusAccServerEntry.10 RO

15 radiusAccClientTimeouts radiusAccServerEntry.11 RO

16 radiusAccClientUnknownTypes radiusAccServerEntry.12 RO

17 radiusAccClientPacketsDropped radiusAccServerEntry.13 RO

Page 85: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

84 / 95

6.1.15 entityMIB Group

entityPhysical group

No Name Object ID MIB ACCESS

1 entPhysicalTable entityPhysical.1 - 2 entPhysicalEntry entPhysicalTable.1 - 3 entPhysicalIndex entPhysicalEntry.1 - 4 entPhysicalDescr entPhysicalEntry.2 RO 5 entPhysicalVendorType entPhysicalEntry.3 RO 6 entPhysicalContainedIn entPhysicalEntry.4 RO 7 entPhysicalClass entPhysicalEntry.5 RO 8 entPhysicalParentRelPos entPhysicalEntry.6 RO 9 entPhysicalName entPhysicalEntry.7 RO 10 entPhysicalHardwareRev entPhysicalEntry.8 RO 11 entPhysicalFirmwareRev entPhysicalEntry.9 RO 12 entPhysicalSoftwareRev entPhysicalEntry.10 RO 13 entPhysicalSerialNum entPhysicalEntry.11 RO 14 entPhysicalMfgName entPhysicalEntry.12 RO 15 entPhysicalModelName entPhysicalEntry.13 RO 16 entPhysicalAlias entPhysicalEntry.14 RO 17 entPhysicalAssetID entPhysicalEntry.15 RO 18 entPhysicalIsFRU entPhysicalEntry.16 RO

entityMapping group

No Name Object ID MIB ACCESS

1 entPhysicalContainsTable entityMapping.3 - 2 entPhysicalContainsEntry entPhysicalContainsTable.

1 -

3 entPhysicalChildIndex entPhysicalContainsEntry.1

RO

Page 86: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

85 / 95

6.2 Fujitsu Private MIB

6.2.1 nonosSystemGroup

No Name Object ID MIB ACCESS

1 nosResetSystem nonosSystem.1 RW

6.2.2 agentPortConfigEntryGroup

No Name Object ID MIB ACCESS

1 agentPortDot1dBasePort agentPortConfigEntry.1 RO

2 agentPortEKeyingStatus agentPortConfigEntry.28 RO

6.3 IEEE802.1MIB

6.3.1 LldpMIB Group

lldpConfiguration group

No Name Object ID MIB ACCESS

1 lldpMessageTxInterval lldpConfiguration.1 RO

2 lldpMessageTxHoldMultiplier lldpConfiguration.2 RO

3 lldpReinitDelay lldpConfiguration.3 RO

4 lldpTxDelay lldpConfiguration.4 RO

5 lldpNotificationInterval lldpConfiguration.5 RO

lldpPortConfig group

No Name Object ID MIB ACCESS

1 lldpPortConfigTable lldpConfiguration.6 -

2 lldpPortConfigEntry lldpPortConfigTable.1 -

3 lldpPortConfigPortNum lldpPortConfigEntry.1 -

4 lldpPortConfigAdminStatus lldpPortConfigEntry.2 RO

5 lldpPortConfigNotificationEnable lldpPortConfigEntry.3 RO

6 lldpPortConfigTLVsTxEnable lldpPortConfigEntry.4 RO

lldpConfigManAdd group

No Name Object ID MIB ACCESS

1 lldpConfigManAddrTable lldpConfiguration.7 -

2 lldpConfigManAddrEntry lldpConfigManAddrTable.1 -

3 lldpConfigManAddrPortsTxEnable lldpConfigManAddrEntry.1 RO

Page 87: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

86 / 95

lldpStatistics group

No Name Object ID MIB ACCESS

1 lldpStatsRemTablesLastChangeTime lldpStatistics.1 RO

2 lldpStatsRemTablesInserts lldpStatistics.2 RO

3 lldpStatsRemTablesDeletes lldpStatistics.3 RO

4 lldpStatsRemTablesDrops lldpStatistics.4 RO

5 lldpStatsRemTablesAgeouts lldpStatistics.5 RO

lldpStatsTxPort group

No Name Object ID MIB ACCESS

1 lldpStatsTxPortTable lldpStatistics.6 -

2 lldpStatsTxPortTable lldpStatsTxPortTable.1 -

3 lldpStatsTxPortNum lldpStatsTxPortEntry.1 -

4 lldpStatsTxPortFramesTotal lldpStatsTxPortEntry.2 RO

lldpStatsRxPort group

No Name Object ID MIB ACCESS

1 lldpStatsRxPortTable lldpStatistics.7 -

2 lldpStatsRxPortEntry lldpStatsRxPortTable.1 -

3 lldpStatsRxPortNum lldpStatsRxPortEntry.1 -

4 lldpStatsRxPortFramesDiscardedTotal lldpStatsRxPortEntry.2 RO

5 lldpStatsRxPortFramesErrors lldpStatsRxPortEntry.3 RO

6 lldpStatsRxPortFramesTotal lldpStatsRxPortEntry.4 RO

7 lldpStatsRxPortTLVsDiscardedTotal lldpStatsRxPortEntry.5 RO

8 lldpStatsRxPortTLVsUnrecognizedTotal lldpStatsRxPortEntry.6 RO

9 lldpStatsRxPortAgeoutsTotal lldpStatsRxPortEntry.7 RO

lldpLocalSystemData group

No Name Object ID MIB ACCESS

1 lldpLocChassisIdSubtype lldpLocalSystemData.1 RO

2 lldpLocChassisId lldpLocalSystemData.2 RO

3 lldpLocSysName lldpLocalSystemData.3 RO

4 lldpLocSysDesc lldpLocalSystemData.4 RO

5 lldpLocSysCapSupported lldpLocalSystemData.5 RO

6 lldpLocSysCapEnabled lldpLocalSystemData.6 RO

lldpLocManAddr group

No Name Object ID MIB ACCESS

1 lldpLocManAddrTable lldpLocalSystemData.8 -

2 lldpLocManAddrEntry lldpLocManAddrTable.1 -

3 lldpLocManAddrSubtype lldpLocManAddrEntry.1 -

4 lldpLocManAddr lldpLocManAddrEntry.2 -

5 lldpLocManAddrLen lldpLocManAddrEntry.3 RO

6 lldpLocManAddrIfSubtype lldpLocManAddrEntry.4 RO

7 lldpLocManAddrIfId lldpLocManAddrEntry.4 RO

8 lldpLocManAddrOID lldpLocManAddrEntry.6 RO

Page 88: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

87 / 95

lldpRem group

No Name Object ID MIB ACCESS

1 lldpRemTable lldpRemoteSystemsData.1 -

2 lldpRemEntry lldpRemTable.1 -

3 lldpRemTimeMark lldpRemEntry.1 -

4 lldpRemLocalPortNum lldpRemEntry.2 -

5 lldpRemIndex lldpRemEntry.3 -

6 lldpRemChassisIdSubtype lldpRemEntry.4 RO

7 lldpRemChassisId lldpRemEntry.4 RO

8 lldpRemPortIdSubtype lldpRemEntry.6 RO

9 lldpRemPortId lldpRemEntry.7 RO

10 lldpRemPortDesc lldpRemEntry.8 RO

11 lldpRemSysName lldpRemEntry.9 RO

12 lldpRemSysDesc lldpRemEntry.10 RO

13 lldpRemSysCapSupported lldpRemEntry.11 RO

14 lldpRemSysCapEnabled lldpRemEntry.12 RO

lldpRemManAdd group

No Name Object ID MIB ACCESS

1 lldpRemManAddrTable lldpRemoteSystemsData.2 -

2 lldpRemManAddrEntry lldpRemManAddrTable.1 -

3 lldpRemManAddrSubtype lldpRemManAddrEntry.1 -

4 lldpRemManAddr lldpRemManAddrEntry.2 -

5 lldpRemManAddrIfSubtype lldpRemManAddrEntry.3 RO

6 lldpRemManAddrIfId lldpRemManAddrEntry.4 RO

7 lldpRemManAddrOID lldpRemManAddrEntry.5 RO

lldpRemUnknownTLV group

No Name Object ID MIB ACCESS

1 lldpRemUnknownTLVTable lldpRemoteSystemsData.3 -

2 lldpRemUnknownTLVEntry lldpRemUnknownTLVTable.1 -

3 lldpRemUnknownTLVType lldpRemUnknownTLVEntry.1 -

4 lldpRemUnknownTLVInfo lldpRemUnknownTLVEntry.2 RO

lldpRemOrgDefInfo group

No Name Object ID MIB ACCESS

1 lldpRemOrgDefInfoTable lldpRemoteSystemsData.4 -

2 lldpRemOrgDefInfoEntry lldpRemOrgDefInfoTable.1 -

3 lldpRemOrgDefInfoOUI lldpRemOrgDefInfoEntry.1 -

4 lldpRemOrgDefInfoSubtype lldpRemOrgDefInfoEntry.2 -

5 lldpRemOrgDefInfoIndex lldpRemOrgDefInfoEntry.3 -

6 lldpRemOrgDefInfo lldpRemOrgDefInfoEntry.4 RO

Page 89: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

88 / 95

lldpXdot3PortConfig group

No Name Object ID MIB ACCESS

1 lldpXdot3PortConfigTable lldpXdot3Config.1 -

2 lldpXdot3PortConfigEntry lldpXdot3PortConfigTable.1 -

3 lldpXdot3PortConfigTLVsTxEnable lldpXdot3PortConfigEntry.1 RO

lldpXdot3LocPort group

No Name Object ID MIB

ACCESS

1 lldpXdot3LocPortTable lldpXdot3LocalData.1 -

2 lldpXdot3LocPortEntry lldpXdot3LocPortTable.1 -

3 lldpXdot3LocPortAutoNegSupported lldpXdot3LocPortEntry.1 RO

4 lldpXdot3LocPortAutoNegEnabled lldpXdot3LocPortEntry.2 RO

5 lldpXdot3LocPortAutoNegAdvertisedCap lldpXdot3LocPortEntry.3 RO

6 lldpXdot3LocPortOperMauType lldpXdot3LocPortEntry.4 RO

lldpXdot3LocPower group

No Name Object ID MIB ACCESS

1 lldpXdot3LocPowerTable lldpXdot3LocalData.2 -

2 lldpXdot3LocPowerEntry lldpXdot3LocPowerTable.1 -

3 lldpXdot3LocPowerPortClass lldpXdot3LocPowerEntry.1 RO

4 lldpXdot3LocPowerMDISupported lldpXdot3LocPowerEntry.2 RO

5 lldpXdot3LocPowerMDIEnabled lldpXdot3LocPowerEntry.3 RO

6 lldpXdot3LocPowerPairControlable lldpXdot3LocPowerEntry.4 RO

7 lldpXdot3LocPowerPairs lldpXdot3LocPowerEntry.5 RO

8 lldpXdot3LocPowerClass lldpXdot3LocPowerEntry.6 RO

lldpXdot3LocLinkAgg group

No Name Object ID MIB ACCESS

1 lldpXdot3LocLinkAggTable lldpXdot3LocalData.3 -

2 lldpXdot3LocLinkAggEntry lldpXdot3LocLinkAggTable.1 -

3 lldpXdot3LocLinkAggStatus lldpXdot3LocLinkAggEntry.1 RO

4 lldpXdot3LocLinkAggPortId lldpXdot3LocLinkAggEntry.2 RO

lldpXdot3LocMaxFrameSize group

No Name Object ID MIB

ACCESS

1 lldpXdot3LocMaxFrameSizeTable lldpXdot3LocalData.4 -

2 lldpXdot3LocMaxFrameSizeEntry lldpXdot3LocMaxFrameSizeTable.1 -

3 lldpXdot3LocMaxFrameSize lldpXdot3LocMaxFrameSizeEntry.1 RO

Page 90: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

89 / 95

lldpXdot3RemPort group

No Name Object ID MIB

ACCESS

1 lldpXdot3RemPortTable lldpXdot3RemoteData.1 -

2 lldpXdot3RemPortEntry lldpXdot3RemPortTable.1 -

3 lldpXdot3RemPortAutoNegSupported lldpXdot3RemPortEntry.1 RO

4 lldpXdot3RemPortAutoNegEnabled lldpXdot3RemPortEntry.2 RO

5 lldpXdot3RemPortAutoNegAdvertisedCap lldpXdot3RemPortEntry.3 RO

6 lldpXdot3RemPortOperMauType lldpXdot3RemPortEntry.4 RO

lldpXdot3RemPower group

No Name Object ID MIB

ACCESS

1 lldpXdot3RemPowerTable lldpXdot3RemoteData.2 -

2 lldpXdot3RemPowerEntry lldpXdot3RemPowerTable.1 -

3 lldpXdot3RemPowerPortClass lldpXdot3RemPowerEntry.1 RO

4 lldpXdot3RemPowerMDISupported lldpXdot3RemPowerEntry.2 RO

5 lldpXdot3RemPowerMDIEnabled lldpXdot3RemPowerEntry.3 RO

6 lldpXdot3RemPowerPairControlable lldpXdot3RemPowerEntry.3 RO

7 lldpXdot3RemPowerPairs lldpXdot3RemPowerEntry.5 RO

8 lldpXdot3RemPowerClass lldpXdot3RemPowerEntry.6 RO

lldpXdot3RemLinkAgg group

No Name Object ID MIB ACCESS

1 lldpXdot3RemLinkAggTable lldpXdot3RemoteData.3 -

2 lldpXdot3RemLinkAggEntry lldpXdot3RemLinkAggTable.1 -

3 lldpXdot3RemLinkAggStatus lldpXdot3RemLinkAggEntry.1 RO

4 lldpXdot3RemLinkAggPortId lldpXdot3RemLinkAggEntry.2 RO

lldpXdot3RemMaxFrameSize group

No Name Object ID MIB

ACCESS

1 lldpXdot3RemMaxFrameSizeTable lldpXdot3RemoteData.4 -

2 lldpXdot3RemMaxFrameSizeEntry lldpXdot3RemMaxFrameSizeTable.1 -

3 lldpXdot3RemMaxFrameSize lldpXdot3RemMaxFrameSizeEntry.1 RO

lldpXdot1ConfigPortVlan group

No Name Object ID MIB

ACCESS

1 lldpXdot1ConfigPortVlanTable lldpXdot1Config.1 -

2 lldpXdot1ConfigPortVlanEntry lldpXdot1ConfigPortVlanTable.1 -

3 lldpXdot1ConfigPortVlanTxEnable lldpXdot1ConfigPortVlanEntry.1 RO

Page 91: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

90 / 95

lldpXdot1ConfigVlanName group

No Name Object ID MIB

ACCESS

1 lldpXdot1ConfigVlanNameTable lldpXdot1Config.2 -

2 lldpXdot1ConfigVlanNameEntry lldpXdot1ConfigVlanNameTable.1 -

3 lldpXdot1ConfigVlanNameTxEnable lldpXdot1ConfigVlanNameEntry.1 RO

lldpXdot1ConfigProtoVlan group

No Name Object ID MIB

ACCESS

1 lldpXdot1ConfigProtoVlanTable lldpXdot1Config.3 -

2 lldpXdot1ConfigProtoVlanEntry lldpXdot1ConfigProtoVlanTable.1 -

3 lldpXdot1ConfigProtoVlanTxEnable lldpXdot1ConfigProtoVlanEntry.1 RO

lldpXdot1ConfigProtocol group

No Name Object ID MIB

ACCESS

1 lldpXdot1ConfigProtocolTable lldpXdot1Config.4 -

2 lldpXdot1ConfigProtocolEntry lldpXdot1ConfigProtocolTable.1 -

3 lldpXdot1ConfigProtocolTxEnable lldpXdot1ConfigProtocolEntry.1 RO

lldpXdot1Loc group

No Name Object ID MIB

ACCESS

1 lldpXdot1LocTable lldpXdot1LocalData.1 -

2 lldpXdot1LocEntry lldpXdot1LocTable.1 -

3 lldpXdot1LocPortVlanId lldpXdot1LocEntry.1 RO

lldpXdot1LocProtoVlan group

No Name Object ID MIB

ACCESS

1 lldpXdot1LocProtoVlanTable lldpXdot1LocalData.2 -

2 lldpXdot1LocProtoVlanEntry lldpXdot1LocProtoVlanTable.1 -

3 lldpXdot1LocProtoVlanId lldpXdot1LocProtoVlanEntry.1 -

4 lldpXdot1LocProtoVlanSupported lldpXdot1LocProtoVlanEntry.2 RO

5 lldpXdot1LocProtoVlanEnabled lldpXdot1LocProtoVlanEntry.3 RO

lldpXdot1LocVlanName group

No Name Object ID MIB

ACCESS

1 lldpXdot1LocVlanNameTable lldpXdot1LocalData.3 -

2 lldpXdot1LocVlanNameEntry lldpXdot1LocVlanNameTable.1 -

3 lldpXdot1LocVlanId lldpXdot1LocVlanNameEntry.1 -

4 lldpXdot1LocVlanName lldpXdot1LocVlanNameEntry.2 RO

Page 92: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

91 / 95

lldpXdot1LocProtocol group

No Name Object ID MIB

ACCESS

1 lldpXdot1LocProtocolTable lldpXdot1LocalData.4 -

2 lldpXdot1LocProtocolEntry lldpXdot1LocProtocolTable.1 -

3 lldpXdot1LocProtocolIndex lldpXdot1LocProtocolEntry.1 -

4 lldpXdot1LocProtocolId lldpXdot1LocProtocolEntry.2 RO

lldpXdot1Rem group

No Name Object ID MIB

ACCESS

1 lldpXdot1RemTable lldpXdot1RemoteData.1 -

2 lldpXdot1RemEntry lldpXdot1RemTable.1 -

3 lldpXdot1RemPortVlanId lldpXdot1RemEntry.1 RO

lldpXdot1RemProtoVlan group

No Name Object ID MIB

ACCESS

1 lldpXdot1RemProtoVlanTable lldpXdot1RemoteData.2 -

2 lldpXdot1RemProtoVlanEntry lldpXdot1RemProtoVlanTable.1 -

3 lldpXdot1RemProtoVlanId lldpXdot1RemProtoVlanEntry.1 -

4 lldpXdot1RemProtoVlanSupported lldpXdot1RemProtoVlanEntry.2 RO

5 lldpXdot1RemProtoVlanEnabled lldpXdot1RemProtoVlanEntry.3 RO

lldpXdot1RemVlanName group

No Name Object ID MIB

ACCESS

1 lldpXdot1RemVlanNameTable lldpXdot1RemoteData.3 -

2 lldpXdot1RemVlanNameEntry lldpXdot1RemVlanNameTable.1 -

3 lldpXdot1RemVlanId lldpXdot1RemVlanNameEntry.1 -

4 lldpXdot1RemVlanName lldpXdot1RemVlanNameEntry.2 RO

lldpXdot1RemProtocol group

No Name Object ID MIB

ACCESS

1 lldpXdot1RemProtocolTable lldpXdot1RemoteData.4 -

2 lldpXdot1RemProtocolEntry lldpXdot1RemProtocolTable.1 -

3 lldpXdot1RemProtocolIndex lldpXdot1RemProtocolEntry.1 -

4 lldpXdot1RemProtocolId lldpXdot1RemProtocolEntry.2 RO

Page 93: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

92 / 95

6.3.2 IEEE802.1X Group

dot1xPaeSystem group

No Name Object ID MIB

ACCESS

1 dot1xPaeSystemAuthControl dot1xPaeSystem.1 RO

2 dot1xPaePortTable dot1xPaeSystem.2 -

3 dot1xPaePortEntry dot1xPaePortTable.1 -

4 dot1xPaePortNumber dot1xPaePortEntry.1 -

5 dot1xPaePortProtocolVersion dot1xPaePortEntry.2 RO

6 dot1xPaePortCapabilities dot1xPaePortEntry.3 RO

7 dot1xPaePortInitialize dot1xPaePortEntry.4 RO

8 dot1xPaePortReauthenticate dot1xPaePortEntry.5 RO

dot1xPaeAuthConfig group

No Name Object ID MIB

ACCESS

1 dot1xAuthConfigTable dot1xPaeAuthenticator.1 -

2 dot1xAuthConfigEntry dot1xAuthConfigTable.1 -

3 dot1xAuthPaeState dot1xAuthConfigEntry.1 RO

4 dot1xAuthBackendAuthState dot1xAuthConfigEntry.2 RO

5 dot1xAuthAdminControlledDirections dot1xAuthConfigEntry.3 RO

6 dot1xAuthOperControlledDirections dot1xAuthConfigEntry.4 RO

7 dot1xAuthAuthControlledPortStatus dot1xAuthConfigEntry.5 RO

8 dot1xAuthAuthControlledPortControl dot1xAuthConfigEntry.6 RO

9 dot1xAuthQuietPeriod dot1xAuthConfigEntry.7 RO

10 dot1xAuthServerTimeout dot1xAuthConfigEntry.10 RO

11 dot1xAuthReAuthPeriod dot1xAuthConfigEntry.12 RO

12 dot1xAuthReAuthEnabled dot1xAuthConfigEntry.13 RO

13 dot1xAuthKeyTxEnabled dot1xAuthConfigEntry.14 RO

dot1xPaeAuthStats group

No Name Object ID MIB

ACCESS

1 dot1xAuthStatsTable dot1xPaeAuthenticator.2 -

2 dot1xAuthStatsEntry dot1xAuthStatsTable.1 -

3 dot1xAuthEapolFramesRx dot1xAuthStatsEntry.1 RO

4 dot1xAuthEapolFramesTx dot1xAuthStatsEntry.2 RO

5 dot1xAuthEapolStartFramesRx dot1xAuthStatsEntry.3 RO

6 dot1xAuthEapolLogoffFramesRx dot1xAuthStatsEntry.4 RO

7 dot1xAuthEapolRespIdFramesRx dot1xAuthStatsEntry.5 RO

8 dot1xAuthEapolRespFramesRx dot1xAuthStatsEntry.6 RO

9 dot1xAuthEapolReqIdFramesTx dot1xAuthStatsEntry.7 RO

10 dot1xAuthEapolReqFramesTx dot1xAuthStatsEntry.8 RO

11 dot1xAuthInvalidEapolFramesRx dot1xAuthStatsEntry.9 RO

12 dot1xAuthEapLengthErrorFramesRx dot1xAuthStatsEntry.10 RO

13 dot1xAuthLastEapolFrameVersion dot1xAuthStatsEntry.11 RO

14 dot1xAuthLastEapolFrameSource dot1xAuthStatsEntry.12 RO

Page 94: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

93 / 95

dot1xPaeAuthSessionStats group

No Name Object ID MIB

ACCESS

1 dot1xAuthSessionStatsTable dot1xPaeAuthenticator.4 -

2 dot1xAuthSessionStatsEntry dot1xAuthSessionStatsTable.1 -

3 dot1xAuthSessionOctetsRx dot1xAuthSessionStatsEntry.1 RO

4 dot1xAuthSessionOctetsTx dot1xAuthSessionStatsEntry.2 RO

5 dot1xAuthSessionFramesRx dot1xAuthSessionStatsEntry.3 RO

6 dot1xAuthSessionFramesTx dot1xAuthSessionStatsEntry.4 RO

7 dot1xAuthSessionId dot1xAuthSessionStatsEntry.5 RO

8 dot1xAuthSessionAuthenticMethod dot1xAuthSessionStatsEntry.6 RO

9 dot1xAuthSessionTime dot1xAuthSessionStatsEntry.7 RO

10 dot1xAuthSessionTerminateCause dot1xAuthSessionStatsEntry.8 RO

11 dot1xAuthSessionUserName dot1xAuthSessionStatsEntry.9 RO

6.3.3 DCBX MIB

lldpXdcbxObjects

No Name ObjectID MIB

Access

1 lldpXdcbxPortTable lldpXdcbxObjects.1 -

2 lldpXdcbxPortEntry lldpXdcbxPortTable.1 -

3 lldpXdcbxPortNumber lldpXdcbxPortEntry.1 RO

4 lldpXdcbxPortEnable lldpXdcbxPortEntry.2 RO

5 lldpXdcbxPortVersionOper lldpXdcbxPortEntry.3 RO

6 lldpXdcbxPortVersionMax lldpXdcbxPortEntry.4 RO

7 lldpXdcbxPortSeqNo lldpXdcbxPortEntry.5 RO

8 lldpXdcbxPortAckNo lldpXdcbxPortEntry.6 RO

lldpXdcbxFeatures

No Name ObjectID MIB

Access

1 lldpXdcbxFeatTable lldpXdcbxFeatures.1 -

2 lldpXdcbxFeatEntry lldpXdcbxFeatTable.1 -

3 lldpXdcbxFeatType lldpXdcbxFeatEntry.1 RO

4 lldpXdcbxFeatSubType lldpXdcbxFeatEntry.2 RO

5 lldpXdcbxFeatVersionOper lldpXdcbxFeatEntry.3 RO

6 lldpXdcbxFeatVersionMax lldpXdcbxFeatEntry.4 RO

7 lldpXdcbxFeatEnable lldpXdcbxFeatEntry.5 RO

8 lldpXdcbxFeatWilling lldpXdcbxFeatEntry.6 RO

9 lldpXdcbxFeatError lldpXdcbxFeatEntry.7 RO

10 lldpXdcbxFeatAdvertise lldpXdcbxFeatEntry.8 RO

11 lldpXdcbxFeatOperMode lldpXdcbxFeatEntry.9 RO

12 lldpXdcbxFeatSyncd lldpXdcbxFeatEntry.10 RO

13 lldpXdcbxFeatSeqNo lldpXdcbxFeatEntry.11 RO

14 lldpXdcbxFeatPeerWilling lldpXdcbxFeatEntry.12 RO

15 lldpXdcbxFeatLocalParameterChange lldpXdcbxFeatEntry.13 RO

16 lldpXdcbxFeatPg lldpXdcbxFeatures.2 -

Page 95: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

94 / 95

17 lldpXdcbxFeatPgNumTCsSupported lldpXdcbxFeatPg.1 RO

18 lldpXdcbxFeatPgPrioAllocTable lldpXdcbxFeatPg.2 -

19 lldpXdcbxFeatPgPrioAllocEntry lldpXdcbxFeatPgPrioAllocT

able.1

-

20 lldpXdcbxFeatPgPrioAllocPrioId lldpXdcbxFeatPgPrioAllocE

ntry.1

RO

21 lldpXdcbxFeatPgPrioAllocPgIdDesired lldpXdcbxFeatPgPrioAllocE

ntry.2

RO

22 lldpXdcbxFeatPgPrioAllocPgIdOper lldpXdcbxFeatPgPrioAllocE

ntry.3

RO

23 lldpXdcbxFeatPgPrioAllocPgIdPeer lldpXdcbxFeatPgPrioAllocE

ntry.4

RO

24 lldpXdcbxFeatPgBwAllocTable lldpXdcbxFeatPg.3 -

25 lldpXdcbxFeatPgBwAllocEntry lldpXdcbxFeatPgBwAllocTa

ble.1

-

26 lldpXdcbxFeatPgBwAllocPgId lldpXdcbxFeatPgBwAllocEn

try.1

RO

27 lldpXdcbxFeatPgBwAllocBwDesired lldpXdcbxFeatPgBwAllocEn

try.2

RO

28 lldpXdcbxFeatPgBwAllocBwOper lldpXdcbxFeatPgBwAllocEn

try.3

RO

29 lldpXdcbxFeatPgBwAllocBwPeer lldpXdcbxFeatPgBwAllocEn

try.4

RO

30 lldpXdcbxFeatPfc lldpXdcbxFeatures.3 -

31 lldpXdcbxFeatPfcNumTCPFCSupported lldpXdcbxFeatPfc.1 RO

32 lldpXdcbxFeatPfcTable lldpXdcbxFeatPfc.2 -

33 lldpXdcbxFeatPfcEntry lldpXdcbxFeatPfcTable 1 -

34 lldpXdcbxFeatPfcPriority lldpXdcbxFeatPfcEntry.1 RO

35 lldpXdcbxFeatPfcEnableDesired lldpXdcbxFeatPfcEntry.2 RO

36 lldpXdcbxFeatPfcEnableOper lldpXdcbxFeatPfcEntry.3 RO

37 lldpXdcbxFeatPfcEnablePeer lldpXdcbxFeatPfcEntry.4 RO

38 lldpXdcbxFeatAppProto lldpXdcbxFeatures.4 -

39 lldpXdcbxFeatAppProtoTable lldpXdcbxFeatAppProto.1 -

40 lldpXdcbxFeatAppProtoEntry lldpXdcbxFeatAppProtoTab

le.1

-

41 lldpXdcbxFeatAppProtoIndex lldpXdcbxFeatAppProtoEnt

ry.1

RO

42 lldpXdcbxFeatAppProtoSF lldpXdcbxFeatAppProtoEnt

ry.2

RO

43 lldpXdcbxFeatAppProtoOUI lldpXdcbxFeatAppProtoEnt

ry.3

RO

44 lldpXdcbxFeatAppProtoId lldpXdcbxFeatAppProtoEnt

ry.4

RO

45 lldpXdcbxFeatAppProtoPrioTable lldpXdcbxFeatAppProto.2 -

46 lldpXdcbxFeatAppProtoPrioEntry lldpXdcbxFeatAppProtoPri

oTable.1

-

47 lldpXdcbxFeatAppProtoPriority lldpXdcbxFeatAppProtoPri

oEntry.1

RO

48 lldpXdcbxFeatAppProtoEnableDesired lldpXdcbxFeatAppProtoPri

oEntry.2

RO

49 lldpXdcbxFeatAppProtoEnableOper lldpXdcbxFeatAppProtoPri

oEntry.3

RO

50 lldpXdcbxFeatAppProtoEnablePeer lldpXdcbxFeatAppProtoPri

oEntry.4

RO

Page 96: PRIMERGY 10GbE Connection Blade 18/8 User Guide V.6manuals.ts.fujitsu.com/file/9251/sbax2-ug-en.pdf · 3.1 Configuring VLAN ... The PRIMERGY 10GbE Connection Blade 18/8 has a reset

PRIMERGY 10GbE Connection Blade 18/8 User Guide

95 / 95

6.4 Trap List

The PRIMERGY 10GbE Connection Blade 18/8 supports the following SNMP traps. - coldStart

is sent when booting up - linkDown is sent occurring link-down

- linkup is sent occuriing lin-up - authenticationFailure

is sent when failing SNMP authentication - newRoot is sent when becoming root bridge - topologyChange

is sent when occurring STP topology change - lldpRemTablesChange is sent when changing adjacent device information management table.

- risingAlarm is sent when exceeding the uppder threshold of alarm entry - fallingAlarm

is sent when falling below the lower threshold of alarm entry - lldpXdcbxMiscControlError is sent when occurring error except lldpXdcbxDupControlTlv in control sub TLV -lldpXdcbxMiscFeatureError

is sent when occurring error except lldpXdcbxDupFeatureTlv and lldpdcbxPeerNoFeat in Feature sub TLV.

-lldpXdcbxMultiplePeers

is sent when detecting multiple peers -lldpXdcbxLldpTxDisabled

is sent when disabling LLDP Tx

-lldpXdcbxLldpRxDisabled is sent when disabling LLDP Rx -lldpXdcbxDupControlTlv is sent when there are more than 2 control sub TLVs

-lldpXdcbxDupFeatureTlv is sent when there are more than 2 feature sub TLVs -lldpXdcbxPeerNoFeat

is sent when the peer doesn’t support the feature -lldpXdcbxPeerNoResp is sent when detecting LLDP response time-out

-lldpXdcbxPeerConfigMismatch is sent when there are configuration mismatch with the peer