HARAN DESIGN CONSULTANCY PVT. LTD.,

- 1 -

PRICE BID Name Of The Work Bank Of India – Hubbali – Dharwad Zonal Office, at Gokul Road, Hubbali – 580020. Karnataka State. Name of the Employer Bank Of India., Hubbali - Dharwad Zonal Office, at Gokul Road, Hubbali – 580020 Name of the Tenderer

HARAN DESIGN CONSULTANCY PVT. LTD.,

- 2 -

ELECTRICAL & DATA CABLING WORK FOR BANK OF INDIA, HUBBALI-DHARWAD ZONAL OFFICE AT GOKUL ROAD, HUBBALI – 580020.

SPECIAL CONDITIONS

1. Necessary Insurance Policies, such as CAR Policy, / Workmen’s Compensation, Third Party Liability, to be taken before commencing the work and the original policies to be deposited with the Clients.

2. Labour Licence to be taken before commencement of work. 3. The Contractor shall provide everything required to carry out the work within

the stipulated time. The required water and electricity for the work shall also be arranged by him.

4. Our Clients will not pay any mobilization advance and there will not be any escalation for the work.

5. Works Contract Tax as applicable will be deducted at source. 6. No deviation will be allowed in the materials specified and the Tenders are

advised to specify the make of materials list enclosed. 7. This is the Open premises hence workers can execute the works full time. 8. The work may some time need to be executed in night hours also in order to

achieve the target period. 9. Since there are other offices functioning in the building, the work should not

hamper the others functioning. 10. Necessary safety arrangements shall be done during execution.

Signature of Tenderer : Address : Date:

HARAN DESIGN CONSULTANCY PVT. LTD.,

- 3 -

ELECTRICAL & DATACABLING WORK FOR BANK OF INDIA, HUBBALI-DHARWAD ZONAL OFFICE AT GOKUL ROAD, HUBBALI – 580020.

PREAMBLE 1.1 The Tenderer is requested to inspect the site and obtain for himself on his own

responsibility and at his own expense all necessary information and particulars to enable him to submit a proper Tender.

1.2 The work includes cost of fitting and fixing the several items in position to floors, walls,

ceiling, etc., in the building in accordance with the drawings or as may be directed and it may be necessary to make hole, chases, etc., on floors, walls, ceilings, etc., as may be shown in the drawings. He must not only take not of these provision but must also allow for such as he may be required to do at the time of work is taken up by him and it will be deemed that his rates take into account all force able contingencies which will include making good disturbed floors, walls, ceilings, to their original condition.

1.3 The description in the bills of quantities are brief and have been compiled as correctly as

possible but are not meant to be exhaustive. 1.4 The contractor should arrange for inspection of the sample of each item by the Architects

before proceeding with the work of manufacturing other units. The samples should be produced for inspection and approval of the Architect in the stages (1) after the same is assembled and made ready as per the Architect’s drawings and (2) after completing the finishing items viz., polishing / painting etc.,

1.5 It may clearly be noted that the inspection and approval of the items of work at any stage

shall not exonerate the Contractor of his responsibilities in respect of the quality of work, workmanship and quality of materials.

1.6 The Employer reserves the right to split the contractor amongst more than one agency

and the rates quoted by the Tendered for individual items should be self supporting and should hold good even for part orders. The rates should also include taxes like excise duty sales tax, octroi work contract tax if any levied by the Central Government/State Government for the present and future. VAT & Service tax will be paid extra as per statuary requirement.

1.7 The work should be completed as per the items specified elsewhere in the document and

the rate quote shall include for doing work round the clock. No extra is payable in this respect.

1.8 The work involves coordination with the work of other agencies and hence, a supervisor

is to be posted at site for taking instructions and should be available for discussions. 1.9 The work should be carried out without any inconvenience to the other agencies. The

work place should be kept clean and tidy. The rubbish should be cleaned then and there.

HARAN DESIGN CONSULTANCY PVT. LTD.,

- 4 -

1.10 The complete programmed for the working at site will have to be approved by the Architect and the Client’s Engineers before commencing the work in order not to cause any inconvenience to the occupants.

1.11 The Tenderer is advised to read the enclosed list of approved make of materials and

offer the brand name in the space given in the list. Signature of Tenderer : Address : Date : Note : The price bid shall be submitted in a separate cover.

HARAN DESIGN CONSULTANCY PVT. LTD.,

- 5 -

MATERIAL SPECIFICATIONS FOR ELECTRICAL WORKS 1. PVC RIGID PIPE KALINGA/SUPER/Equivalent 2. PVC ROLL PIPE SUPER DAIDA 3. WIRES AND CABLES FINOLEX/POLYCAB/RR KABEL 4. SWITCH AND SOCKETS MODULAR MK/ROMA 5. LIGHT FITTINGS PHILIPS / WIPRO 6. DB & MCB STANDARD/MDS/INDO ASIAN 7. AC STARTER, PLUG SOCKET STANDARD/MDS/INDO ASIAN 8. TELEPHONE SOCKET ANCHOR ROMA/ MK 9. DATA, VOICE CABLE CAT VI D-LINK/ADHYA 10. LUGS DOWELLS 11. TERMINALS ESSEN/ELMEX 12. LT CABLES CCI/UNIVERSAL 13. E-CAT6 PATCH PANNEL D-LINK/AVAYA 14. FAN (WALL BRACKET/EXHAUST) ORIENT/KHAITAN 15. TELEPHONE CABLE NETCO

Sl.No Description Of Work Qty Unit Rate AmountA MAIN PANEL & DISTRIBUTION BOARDS

1

Fixing the missing switches, MCB's and terminating including necessary accessories with the existing panel boards, all DB's etc., 1 Job

B Supply&Installation&Commisioing of the following 1 POWER DB(12 WAY TPN PHASE SEGRIGATED DB)

Supply & fixing of 3 phase 12 Way Segregated TPN DB with nuetral bar,earth bar,cables ties,top and bottom removable gland plate and with necessary adopter boxes if any.The DB should be IP 42 metallic double door with provisioin of MCB&ELCB etc as required including cuting of wall and plastering the same with neat finish.It comprising as flolows:- Incomer : 1 X 100A 4P LBS & 3X2P ELCB 100 mA Outgoings: 20A DP MCB -9nos 10/6A SP MCBs- 12Nos

1 Set

2 Supply&Installation&Commisioing of the following LIGHTING DB(12WAY TPN PHASE SEGRIGATED DB)Supply & fixing of 3 phase 12 Way Segregated TPN DB with nuetral bar,earth bar,cables ties,top and bottom removable gland plate and with necessary adopter boxes if any.The DB should be IP 42 metallic double door with provisioin of MCB&ELCB etc as required including cuting of wall and plastering the same with neat finish.It comprising as flolows:- Incomer : 1 X 63A 4P LBS & 3X2P ELCB 100 mA Outgoings: 20A DP MCB -9nos 10/6A SP MCBs- 9Nos

2 Set

3 CDB(12 WAY SPN DB)Supply & fixing of 3 phase 12 Way SPN DB with nuetral bar,earth bar,cables ties,top and bottom removable gland plate and with necessary adopter boxes if any.The DB should be IP 42 metallic double door with provisioin of MCB&ELCB etc as required including cuting of wall and plastering the same with neat finish.It comprising as flolows:- Incomer : 1 X 63A DP LBS & 3X2P ELCB 100 mA Outgoings: 20A DP MCB -9nos 10/6A SP MCBs-8Nos

2 Set

Specification for Electrical & Networking works for Bank of India - Hubbali-Dharwad Zonal Office

Sl.No Description Of Work Qty Unit Rate Amount4 Supply&Installation of the following with the necessary

enclosure and adopter boxes if necessary,a) 63A TPN MCB 2 Setb) 63 DP MCB 2 Set

5Supply and fixing of 20A MC plug and socket with 20A SP MCB for A/c control 3 Set

C LT CABLES1 Supply&Laying of the following cables in built up

trenches,on wall, or in the ground as per the case may be,with proper clamping with necessary fixing materials etc. Installing testing&commisioing of 1100V grede UGcable as per IS 7098/1554 ( Finolex/ Universal)

a 3.5Corex70Sqmm Aluminium Armored cable 50 Mtrb 3.5Corex50Sqmm Aluminium Armored cable 35 Mtrc 3.5Corex25Sqmm Aluminium Armored cable 100 Mtr2 End Termination of the above cables with proper

Glands and Lugsa 3.5Corex70Sqmm Aluminium Armored cable 4 Setb 3.5Corex50Sqmm Aluminium Armored cable 4 Setc 3.5Corex25Sqmm Aluminium Armored cable 8 Set

D WIRING1 Wiring with 2 x 1.5sq.mm pvc insulated copper along

with 1R X 1.5 sq.mm green pvc insulated copper cable in suitable pvc conduit from point to switch board with all accessories, having 6A modular switch on GI modular box and modular plate for the following points:a) One light Controlled by One Switch 70 Ptsb) Two Lights Controlled by one Switch 50 Ptsc) 6A Switch box Sockets in the switch board itself 12 Ptsd) 6A Individual Switches wherever necessary 15 Ptse) Exhaust Fan points 4 Ptsf) Ceiling fan with regulator 6 Ptsg) Wall bracket fan (6A Switch & 6A Sockets) 15 Ptsh) Calling Bell with Push Bell 3 Pts

2 Supply and run of 2R X 2.5 sq.mm + 1R X 1.5 sq.mm pvc insulated cu. cable in suitable pvc conduit from each switch board to DB 1200 Mtr

Sl.No Description Of Work Qty Unit Rate Amount3 Supply and run of 2x4 + 1x 2.5 sq.mm pvc insulated

copper cable in suitable pvc conduit from each power point to main PDB 800 Mtr

4 Supply and run of 2x4 + 1x2.5 sq.mm PVC insulated cu. cable in suitable PVC pipe for computer points 1100 Mtr

5 Supply and run 2x6 sq.mm + 1x4 sq.mm cu. wire 120 Mtr6 Supply and run of 4x10.0 sq.mm + 2R 4.0 sq.mm PVC

insulated cu. cable in PVC conduit for 3nos of 15kVA UPS 75 Mtr

7 Supply and run of 3 X 10.0 sq.mm PVC insulated cu. cable in suitable PVC conduit from UPS output UPS DB

70 Mtr

E POWER POINT OUTLETS1 Supply&Installation of 3 Nos of 6A Sockets + 2Nos of 6A

Switches controlled by 16A switch with front plate with enclosure and other accessories etc.,(MK/ROMA) 45 Set

2 Supply&Installation of 1Nos of 6A Socket controlled by 1No 6A Switch with front plate with enclosure and other accessories etc..(MK /ROMA) 45 Set

3 Supply&Installation of 1Nos of 16A Socket controlled by 1No 16A Switch with front plate with enclosure and other accessories etc..(MK /ROMA) 10 Set

F LIGHTING FIXTURES1 Removing & refixing of existing 2 x 2 light fittings

as per new electrical layout after changing the bulbs with new 2x36W bulbs and electronic Chokes with necessary accessories. 80 Set

2 removing & refixing of existing 2 x18W down lighters light fittings as per new electrical layout changing the bulbs with new 2 x 18W bulbs and electronic chokes with necessary accessories. 70 Set

3

Supply and Fixing of 1x10w down light fitting with CFL lamp with all necessary accessories and hardwares required 12 Set

4Supply and Fixing of 16” wall mounting fan with all necessary accessories and hardwares required. 20 Set

5

Supply and Fixing of 9” Exhaust fan for UPS Room with louvres and all necessary accessories and hardwares.

4 Set

Sl.No Description Of Work Qty Unit Rate Amount6 Supply and Fixing of 1x36w box type tube light fitting

with all necessary accessories and hardwares.10 Set

G TELEPHONE CABLING:-1 Supply and fixing of RJ 11 tel. socket on modular box

and plate 60 Pt2 Supply and fixing of 100 pair Tel. krone box with

complete interconnection 1 Set3 Supply and run of 50 pair, jelly filled telephone cable

from telecommunication box to GF BSNL box 60 Mtr4 Supply and run of 2 pair telephone cable in PVC

conduit 900 Mtr5 Supply and run of 5 pair telephone cable in PVC

conduit 200 Mtr

H EARTHING WORKS :1 Providing safe earth electrode T – 80 3 mtrs. with

moisture booster/ backfilling compound including masonry chamber works 4 Set

2 Providing 1x25 sq.mm Cu. Cable 150 Mtr3 Providing Cu. earth link – 12W 2 Nos

I DATA CABLING 1 Supply and fixing of RJ 6 I/0 socket with tower plate

and modular box 60 Set2 Supply and run of CAT 6 comp. cable 1420 Mtr3 Supply and fixing of I/0 pin with crimping and testing

120 No4 Supply and Fixing of 1M Mounting cord 60 No5 Supply and Fixing of 2M Mounting cord 60 No6 Supply and Fixing of 3M Mounting cord 10 No

7Supply & fixing of 24U Floor Mounting rack with power guard 1 Set

8 Supply & fixing of 24 Port Jack Panel 4 Set9 Supply & fixing of 24 Port Switch 10/100 Speed 4 SetJ SPEAKER CABLING1 Supply and installation of 2 core 24/0.2 mm dia twin

twisted cu. conductor PVC insulated cable drawn in 20 mm dia medium grade PVC conduit (ISI marked) including clamping the same with GI clamps on ceiling, wall through partitions etc chase cutting of wall wherever required. 450 Mtr

Sl.No Description Of Work Qty Unit Rate Amount2 Supply and installation of 6W ceiling mounted ring

speaker in plastic mould with built in transformer 20 Nos3 Supply and installation of volume control housed in GI

box 10 Nos

K EB RELATED WORKS1 Supply and fixing of 40 kvar Automatic capacitor

control panel with 7 stage of 10/7.5/7.5/5/5/2.5/2.5 kvar with necessary Air break contactors, controlled by TP MCBs, auxillary contactors, 7 stage capacitor relays and all interconnection

1 Set

ELECTRICAL WORKS GRAND TOTAL: