prex ii vacuum box, shielding and septu m design status

10
PREX II Vacuum Box, Shielding and Septum Design Status Alan Gavalya 11 APR 14

Upload: penda

Post on 23-Feb-2016

60 views

Category:

Documents


0 download

DESCRIPTION

PREX II Vacuum Box, Shielding and Septu m Design Status. Alan Gavalya 11 APR 14. Septum Mount w/ Absorber. Vertical Section. Horizontal Section. Septum Magnet. Septum Status. PREX-II utilizes the eight large coils in the existing Septum Magnet Existing Magnet has one large coil damaged - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: PREX II Vacuum Box, Shielding and Septu m  Design Status

PREX II Vacuum Box, Shielding and Septum Design Status

Alan Gavalya11 APR 14

Page 2: PREX II Vacuum Box, Shielding and Septu m  Design Status

Septum Mount w/ Absorber

Page 3: PREX II Vacuum Box, Shielding and Septu m  Design Status

Vertical Section

Page 4: PREX II Vacuum Box, Shielding and Septu m  Design Status

Horizontal Section

Page 5: PREX II Vacuum Box, Shielding and Septu m  Design Status

Septum Magnet

Page 6: PREX II Vacuum Box, Shielding and Septu m  Design Status

Septum Status

PREX-II utilizes the eight large coils in the existing Septum Magnet

Existing Magnet has one large coil damaged

Need to replace damaged coil, estimated at $10k, drawings exist, 7 to 9 months from procurement to delivery of coil.

Page 7: PREX II Vacuum Box, Shielding and Septu m  Design Status

Vacuum Box w/ Collimator

Page 8: PREX II Vacuum Box, Shielding and Septu m  Design Status

Tungsten Collimator Inner cylinder 30% Cu-70% W Water-cooled slug with Cu

sleeve brazed, similar to Qweak collimator

Outer box Tungsten

Power deposited: Inner cylinder 25.7 W/mA 70mA results in 1800W

Outer box 3.1 W/mA

Page 9: PREX II Vacuum Box, Shielding and Septu m  Design Status

Tungsten Collimator “Rough” calculation on

initial design gives max temperature of Cu-W cylinder at 57.8 C

With use of Dynaflux pump-cooler system at max flow of 4 GPM

Recommend FEA simulation be done for more accuracy

Need request of 3-4 weeks to analyze

Page 10: PREX II Vacuum Box, Shielding and Septu m  Design Status

Slow and Steady Pace

Questions?