GYMNASIUM
STEM BLDG.
MIDDLE SCHOOL
CHURCH
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:30 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
As indicated
A000
COVERSHEET
BEM
MS
1/29/16
14640GILEAD
GILEAD-BLOOMFIELD COMPLEX RENOVATION1931 ROCKY CREEK ROADMACON, GEORGIA 31206
MACON-BIBB COUNTY
PROJECT DIRECTORYVICINITY MAP PROJECT INFORMATION
APPLICABLE CODES
MACON-BIBB COUNTY RECRECATION DEPARTMENT150 WILLIE SMOKIE GLOVER DRIVEMACON, GA 31201TEL: (478) 751-9280
REGINALD MOORE, INTERIM [email protected]
MACON-BIBB COUNTYOWNER
1700 COMMERCE DRIVE, NWATLANTA, GA 30318TEL: 404-605-0690FAX: 404-605-0890
TOM M. SAYER, - PRINCIPAL-IN-CHARGEBRUCE MORRIS - PROJECT ARCHITECT
SIZEMORE GROUP, LLCARCHITECT
5185 PEACHTREE PKWY NWSUITE 240NORCROSS, GA 30092TEL: 770-368-1399
HOLLY JEFFREYS, P.E.
FORSITE GROUPSTRUCTURAL ENGINEER
1931 ROCKY CREEK ROADMACON, GEORGIA 31206
MACON-BIBB COUNTYGILEAD-BLOOMFIELD COMPLEX RENOVATION
PROJECT NAME
LOCATION
14640GILEADPROJECT NUMBER
MACON-BIBB COUNTY BUSINESS DEVELOPMENT SERVICES6820 CHERRY STREET SUITE 500MACON, GA 30201478-803-0470
PERMITTING AGENCY
TYPE IIB, NON SPRINKLERED
BUILDINGS
PRIMARY - GROUP BACCESSORY - GROUP A-3
27,796 SF - TOTAL ONE STORY BUILDING
316 CORPORATE PKWYMACON, GA 31210478-745-1691
TIM TROTTER, P.E.
NOTTINGHAM, BROOK & PENNINGTON
MECHANICAL ELECTRICAL PLUMBINGENGINEER
216 CHURCH STREETDECATUR, GA 30030TEL: 404-373-9075FAX: 404-373-9076
PHIL BALDWIN, VICE PRESIDENT
SPIKER BALDWIN ASSOCIATESSPECIFICATIONS
3585 HIGHWAY 317SUITE 401-ASUWANEE, GA 30024TEL: 770-614-0630FAX: 770-614-0680
MARK PHILLIPS, PRESIDENT
PHILLIPS-LANGLEY & ASSOCIATESHARDWARE CONSULTANT
SHEETNUMBER SHEET NAME ISSUE DATE
ARCHITECTUREA000 COVER SHEET 1/29/16A001 SYMBOLS, LEGENDS, AND ABBREVIATIONS 1/29/16A002 GYMNASIUM LIFE SAFETY 1/29/16A003 SCHOOL BUILDING LIFE SAFETY 1/29/16A101 GYMNASIUM DEMOLITION PLAN 1/29/16A102 SCHOOL BUILDINGS DEMOLITION PLANS 1/29/16A103 GYMNASIUM FLOOR PLAN 1/29/16A104 SCHOOL BUILDINGS FLOOR PLANS 1/29/16A105 GYMNASIUM AND STEM BUILDING ROOF PLANS 1/29/16A106 FORMER CHURCH ROOF PLAN 1/29/16A201 GYMNASIUM EXTERIOR ELEVATIONS 1/29/16A202 SCHOOL BUILDINGS EXTERIOR ELEVATIONS 1/29/16A301 GYMNASIUM BUILDING CEILING PLAN 1/29/16A302 SCHOOL BUILDINGS CEILING PLANS 1/29/16A401 GYMNASIUM BUILDING FINISH PLAN 1/29/16A402 SCHOOL BUILDINGS FINISH PLANS 1/29/16A501 ENLARGED PLANS AND INTERIOR ELEVATIONS 1/29/16A701 DOOR SCHEDULE AND DETAILS 1/29/16
ELECTRICAL ENGINEERINGED101 GYMNASIUM- DEMOLITION- ELECTRICAL 1/29/16ED102 SCHOOL BUILDINGS- DEMOLITION- ELECTRICAL 1/29/16E001 LEGEND AND SCHEDULE- ELECTRICAL 1/29/16E201 GYMNASIUM- NEW WORK- LIGHTING 1/29/16E202 SCHOOL BUILDINGS- NEW WORK- LIGHTING 1/29/16E301 GYMNASIUM- NEW WORK- POWER/TELECOM 1/29/16E302 SCHOOL BUILDINGS- NEW WORK- POWER/TELECOM 1/29/16E401 GYMNASIUM- NEW WORK-HVAC POWER/SYSTEMS 1/29/16E402 SCHOOL BUILDINGS- NEW WORK- HVAC
POWER/SYSTEMS1/29/16
E501 RISER DIAGRAMS- ELECTRICAL 1/29/16E601 DETAILS- ELECTRICAL 1/29/16E701 PANEL SCHEDULES- ELECTRICAL 1/29/16
MECHANICAL ENGINEERINGMD101 GYMNASIUM- DEMOLITION- HVAC 1/29/16MD102 SCHOOL BUILDINGS- DEMOLITION- HVAC 1/29/16M001 ABBREVIATIONS, LEGENDS & SCHEDULES- HVAC 1/29/16M002 DETAILS- HVAC 1/29/16M201 GYMNASIUM- NEW WORK- HVAC 1/29/16M202 SCHOOL BUILDINGS- NEW WORK- HVAC 1/29/16
PLUMBING ENGINEERINGPD101 GYMNASIUM- DEMOLITION- PLUMBING 1/29/16PD102 SCHOOL BUILDINGS- DEMOLITION- PLUMBING 1/29/16P001 LEGEND, SCHEDULE, NOTES & DETAILS- PLUMBING 1/29/16P201 GYMNASIUM- NEW WORK- PLUMBING 1/29/16P202 SCHOOL BUILDINGS- NEW WORK- PLUMBING 1/29/16P301 LARGE SCALE GYMNASIUM- NEW WORK- PLUMBING 1/29/16
STRUCTURAL ENGINEERINGS001 STRUCTURAL GENERAL NOTES 1/29/16S101 ROOF FRAMING PLAN 1/29/16S102 FRAMING DETAILS 1/29/16
TBDGENERAL CONTRACTOR
GYMNASIUM BUILDING
CONSTRUCTION TYPE:OCCUPANCY TYPE:
AREA:
TYPE IIB, NON-SPRINKLERED
PRIMARY - GROUP EACCESSORY - GROUP A-3
6,352 SF - TOTAL ONE STORY BUILDING
MIDDLE SCHOOL BUILDING
CONSTRUCTION TYPE:
OCCUPANCY TYPE:
AREA:
TYPE IIB, NON-SPRINKLERED
PRIMARY - GROUP EACCESSORY - GROUP A-3
2,652 SF - TOTAL ONE STORY BUILDING
STEM BUILDING
CONSTRUCTION TYPE:
OCCUPANCY TYPE:
AREA:
6,640 SF - WITHIN SCOPE OF WORK
ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES, STANDARDS, AND GOVERNINGAUTHORITIES AS RELATED TO THIS PROJECT INCLUDING BUT NOT LIMITED TO:
BUILDING INTERNATIONAL BUILDING CODE (IBC), 2012 EDITIONW/ STATE OF GEORGIA 2014 AMENDMENTS
LIFE SAFETY NFPA 101, LIFE SAFTEY CODE, 2012 ED.RULES AND REGULATIONS OF THE GEORGIA SAFETY FIRE COMMISIONER, CHAPTER 120-3-3
FIRE PREVENTION STANDARD FIRE PREVENTION CODE (INTERNATIONAL FIRE CODE), 2012 EDITION W/ STATE OF GEORGIA 2014 AMENDMENTS
MECHANICAL STANDARD MECHANICAL CODE (INTERNATIONAL MECHANICAL CODE), 2012 EDITION W/ STATE OF GEORGIA 2014 AMENDMENTS
PLUMBING STANDARD PLUMBING CODE (INTERNATIONAL PLUMBING CODE), 2012 EDITION W/ STATE OF GEORGIA 2014 AMENDMENTS
ELECTRICAL NFPA NATIONAL ELECTRICAL CODE, 2011 EDITION
GAS STANDARD GAS CODE (INTERNATIONAL FUEL GAS CODE),2012 EDITION W/ STATE OF GEORGIA 2014 AMENDMENTS
ENERGY INTERNATIONAL ENERGY CONSERVATION CODE, 2009 ED.W/ STATE OR GEORGIA 2011 AND 2012 SUPPLEMENTS AND AMENDMENTS
HANDICAP STATE OF GEORGIA ACCESSIBILITY CODE, ACCESSIBILITY CHAPTER 120-3-20a-.016 (.01-.08) 2010 ADA STANDARDS FOR
ACCESSIBLE DESIGN
DRAWING SHEET INDEX
CAMPUS MAP
ABV ABOVEACT ACOUSTIC CEILING TILEADJ ADJACENT; ADJUSTABLEADMIN ADMINISTRATIVEAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAHU AIR HANDLING UNITAL/ALUM ALUMINUMALT ALTERNATE/ALTERNATIVEAPPROX APPROXIMATEARCH ARCHITECTURALASSOC ASSOCIATE(S)AUX AUXILARYAVG AVERAGE
BLDG BUILDINGBO BOTTOM OFBOS BOTTOM OF STEELBTU BRITISH THERMAL UNITBTU/HR BRITISH THERMAL UNIT PERHOUR
CF CUBIC FEETCFM CUBIC FEET PER MINUTECIP CAST-IN-PLACECJ CONTROL JOINTC/L CENTERLINECLG CEILINGCLKG CAULKINGCLO/CLOS/CLST CLOSETCMU CONCRETE MASONRY UNITCOL COLUMNCONC CONCRETECONF CONFERENCECORR CORRIDORCPT CARPETCU CUBIC
DEPT DEPARTMENTDIA DIAMETERDIFF DIFFERENCEDIM DIMENSIONDBL DOUBLEDN DOWNDS DOWNSPOUTDWG DRAWINGDF DRINKING FOUNTAIN
EA EACHE EASTELEC ELECTRIC (ELECTRICAL)EL ELEVATIONELEV ELEVATOREMER EMERGENCYEQ EQUALEQPT EQUIPMENTEXST EXISTINGEXP EXPANSIONEJ EXPANSION JOINT
FOF FACE OF FINISHFOM FACE OF MASONRYFOS FACE OF STUDSFT FEETFPM FEET PER MINUTEFIN FINISHFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFIXT FIXTUREFL FLOOR
GC GENERAL CONTRACTGA GAGE (GAUGE)GALV GALVANIZEDGL GLASSGPY GYPSUM
HVAC HEATING, VENTILATING &AIR CONDITIONING
HGT HEIGHTHM HOLLOW METALHORIZ HORIZONTALHP HORSEPOWERHB HOSE BIBB
IN INCHINSUL INSULATION
JC JANITOR CLOSET
LAB LABORATORYLAM LAMINATELNDG LANDINGLAV LAVATORYLH LEFT HANDLEV LEVEL
MGR MANAGERMFR MANUFACTURERMFG MANUFACTURING
MEZZ MEZZANINEMISC MISCELLANEOUS
N NORTHNIC NOT IN CONTRACTNTS NOT TO SCALENO NUMBER
OC ON CENTEROH OPPOSITE HANDOPNG OPENINGOPP OPPOSITE
PR PAIRPVMT PAVEMENTPLAM PLASTIC LAMINATEPLYWD PLYWOODPT PORCELAIN TILELB POUNDPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHR RADIUSREF REFERENCERH RIGHTHANDR RISER
RD ROOF DRAINRM ROOMRO ROUGH OPENING
SCH SCHEDULESHT SHEETSIM SIMILARS SOUTHSPKR SPEAKERSQ SQUARESQFT SQUARE FOOTSS STAINLESS STEELSTD STANDARDSTA STATIONSTL STEELSTOR STORAGESTRUCT STRUCTURALSYM SYMMETRICAL
TEL TELEPHONETV TELEVISIONTEMP TEMPEREDT&G TONGUE AND GROOVETOS TOP OF STEELTYP TYPICAL
VAC VACUUMVEST VESTIBULEVWC VINYL WALL COVERING
WSCT WAINSCOTWC WATER CLOSETWT WEIGHTW WESTW/ WITHWD WOOD
A1011
SIM
1 View Name1/8" = 1'-0"A101SHEET NUMBER
DRAWING NUMBERTITLES
A
1
1
PARTITION TYPE
COLUMN LINE
GLASS TYPE
100DOOR NUMBER
CLASSROOM300
EL. 0'-0"
ROOM NAMENUMBERELEVATION
8'-0" ACEILING HEIGHT ABOVEFINISHED FLOOR
CEILING TYPE
REVISION NUMBER
AT FLOOR PLANS:INDICATES DIMENSION TOCENTERLINE OF COLUMN,FINISHED FACE OF GYPSUMBOARD OR CMU AT WALLS.
AT DETAILS & SECTIONS:INDICATES DIMENSION TOCENTERLINE OF COLUMN, FACEOF STUD OR CMU AT PARTITIONSOR CHANGE IN MATERIAL.
SHEET NUMBERDETAIL NUMBER
DETAIL
1A101SHEET NUMBER
SECTION NUMBER
BUILDING SECTION
1A101SHEET NUMBER
ELEVATION NUMBER
ELEVATION
EARTH
GRANULAR DRAINAGEMATERIAL
GROUT
STONE
CONCRETE MASONRYUNIT
RIGID INSULATION
STEEL
PLYWOOD
CONCRETE
FINISHED WOOD
GYPSUM WALL BOARD
BATT INSULATION
DIMENSIONAL LUMBERWOOD BLOCKING
WATERPROOFING
DIMENSIONAL LUMBERCONTINUOUS WOODFRAMING
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:30 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
12" = 1'-0"
A001
SYMBOLS,LEGENDS,
ANDABBREVIATIONS
BEM
MS
1/29/16
14640GILEAD
MATERIAL LEGENDABBREVIATIONS
SYMBOL LEGEND
100
ROOM NAME
1
100 SF AREA OF ROOM
CALCULATED OCCUPANCY LOAD
EGRESS WIDTH (INCHES)
EGRESS FACTOR
TOTAL EGRESS CAPACITY OFOPENING (# PERSONS)
PATH OF TRAVEL
2 NUMBER OF OCCUPANTS FROM ROOM OR AREA
OCCUPANCY FACTOR (SF/PERSON)
36 NUMBER OF OCCUPANTS COMBINED FROMMULTIPLE ROOMS OR AREAS
FIRE RATING -1 HOUR
FIRE EXTINGUISHER WITH CABINET
BRACKET MOUNTED FIRE EXTINGUISHER
FE
FE
.2"36" 180
BUILDING PARAMETERS
QUALIFICATIONS: 1. The Building is not potected by an automatic sprinkler system
USE: Assembly (Recreation)
Occupancy: NFPA 101: Existing Assembly (per chapter 13)IBC: Assembly Group A-3 (per section 303)
Construction Type: II-B
CODE ANALYSIS
IBC Chapter 4 – Special Detailed Requirements based on use and occupancy
Superseded by NFPA as per the Georgia Amendments January 1, 2010
IBC Chapter 5 – General Building Heights and Areas
Note: Existing building: No new constructed space
IBC Table 508.4 : Required Separation of Occupancies
SprinkleredBusiness - Assembly: 1 HourBusiness - Low Hazard Storage S-2: 1 Hour
715 Opening Protective
Table 716.5 – OPENING FIRE PROTECTION ASSEMBLIES RATINGS AND MARKINGS
Fire barriers of 1-hour fire-resistance-rated construction:
- Shaft and exit enclosures wall 1 1- Other Fire Barriers 1 3/4 Fire partitions:
- Corridor Walls 1 1/30.5 1/3
- Other Fire Partitions 1 3/40.5 1/3
Smoke Barriers 1 1/3
IBC Chapter 8 – Interior Finishes
Superseded by NFPA Life Safety Code as per the Georgia Amendments January 1, 2010.
NFPA Chapter 7 – Means of EgressIBC Chapter 10 – Means of Egress is Superseded by NFPA Life Safety Code as per theGeorgia Amendments January 1, 2010.
NFPA 7.1.3.1 - Exit Access Corridors: Corridors used as exit access and serving an area havingan occupant load exceeding 30 shall be separated from other parts of the building by wallshaving not less than a 1-hour fire resistance rating.
Table 7.3.1.2 Occupant Load FactorsArea Type Area factor, per person
Business Use 100 sf netClassrooms 20 sf netShops, Laboratories, Vocational Room 50 sf netExcercise Room
With Equipment 50 sf netWithout Equipment 15 sf net
Kitchen 100 sf netStorage
In other than storage or 500 sf netmercantile occupancies
AssemblyConcentrated w/o fixed seating 7 sf netLess concentrated use 15 sf netwithout fixed seating
NFPA 7.3 - Capacity of Means of Egress (Per Table 7.3.3.1):
Stairs: .3”/Occupant
Level components and ramps: .2”/Occupant
NFPA 38.2.5 Arrangements of Means of Egress
In buildings other than those protected throughout by an approvedautomatic sprinkler system, dead-end corridors shall not exceed 20 ft.
In buildings other than those protected throughout by an approvedautomatic sprinkler system, common path of travel shall not exceed 75 ft.
NFPA 38.2.6 Travel Distance to Exits
Travel distance shall not exceed 200 feet in occupancies that are notprotected throughout by an approved sprinkler system
NFPA 38.3.3.2 Interior Wall and Ceiling Finish
Interior Wall and ceiling finish material complying with Section 10.2 shall beClass A or Class B in exits and in exit access corridors
IFC Section 906 Portable Fire Extinguishers: Superseded by NFPA LifeSafety Code as per Georgia Amendments.
NFPA 9.7.4 Manual Extinguishing Equipment9.7.4.1 Where required by the provision of another section of this Code,portable fire extinguishers shall be selected, installed, inspected, andmaintained in accordance with NFPA 10, Standard for Portable FireExtinguishers:
National Fire Protection Association NFPA 10, “Standard for Portable FireExtinguishers”
NFPA 10, requires portable fire extinguishers:· Within easy reach of storage areas for flammables· Throughout buildings, located so that a person does not have to
travel more than 75 feet to reach one.
Building Accessibility – Georgia Accessibility Code
120-3-20.03 (1) All areas of newly designed or newly constructed buildingrequire to be accessible by Rules 120-3-20.07 and 120-3-20.08 shallcomply with the regulations, rules 120-3-20.03 through 120-3-20-46 of theGeorgia Accessibility Code.
2010
42
28
55
21
41
21
22
11
142
142
102
51 51
283
.2"36" 180
.2"36" 180
.2"36" 180
.2"
72"
360
.2"
72"
360
.2"
72"
360
.2"
72"
180
.2"
70"
233
.2"
72"
360
.2"
72"
360
.2" 36"180
WID
TH O
F ST
AIR
142
142
7063
112
964 SF100
KITCHEN
10
LOBBY / GAME ROOM
8497 SF15
GYMNASIUM
566
1238 SF15
AEROBICEXERCISE
83
1253 SF15
WEIGHTTRAINING
83
629 SF15
YOGA ROOM
42
612 SF20
CLASSROOM
30
667 SF20
CLASSROOM
33
HOME TEAM ROOM VISITING TEAM ROOM
SUPPLY
JAN
CLOSET
HOME TEAM LOCKERROOM
MEN'S
VISITOR'S LOCKERROOM
WOMEN'S
SUPPLYSUPPLY
UTILITY
PANTRY
3054 SF15204
CORR
IDO
R
CORR
IDO
R
CORRIDOR
8
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:32 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
1/8" = 1'-0"
A002
GYMNASIUMLIFE SAFETY
BEM
MS
1/29/16
14640GILEAD
LIFE SAFETY LEGENDLIFE SAFETY NOTES
1. LOCATION OF FIRE EXTINGUISHER CABINETS AND FIRE EXTINGUISHERS ISBASED ON 75 FT. TRAVEL DISTANCE.
2. CONTRACTOR TO PROVIDE AND INSTALL (IF NECESSARY) TWOADDITIONAL FIRE EXTINGUISHER CABINETS PER FLOOR IF DIRECTED BYTHE LOCAL AUTHORITIES HAVING JURISDICTION.
3. REFER TO FLOOR PLANS FOR LOCATIONS OF PARTITION TYPES.
CODE RESEARCH
1/8" = 1'-0"A0021 GYMNASIUM BUILDING LIFE SAFETY PLAN
WH
757 SF20
CLASSROOM
38UTILITY
ELEC
176 SF100
WORKROOM
2201 SF
100
RESOURCEROOM
878 SF20
CLASSROOM
44
777 SF20
CLASSROOM
39
381 SF20
CLASSROOM
19
CORRIDOR
BOYSGIRLS
CLOSETH/
C RE
STRO
OM
580 SF20
CLASSROOM
29
83
2
65
44
3919
2
29
JAN
38
2
.2" 72"360
.2"
36"
180
.2"72" 360
.2"
36"
180
21
550 SF20
CLASSROOM
28
719 SF50
SCIENCE LAB
14
688 SF20
CLASSROOM
34
CLOSET
ELECT WOMENS MENS
28
14
34
.2"36" 180
.2"36" 180
.2"36" 180
100
ROOM NAME
1
100 SF AREA OF ROOM
CALCULATED OCCUPANCY LOAD
EGRESS WIDTH (INCHES)
EGRESS FACTOR
TOTAL EGRESS CAPACITY OFOPENING (# PERSONS)
PATH OF TRAVEL
2 NUMBER OF OCCUPANTS FROM ROOM OR AREA
OCCUPANCY FACTOR (SF/PERSON)
36 NUMBER OF OCCUPANTS COMBINED FROMMULTIPLE ROOMS OR AREAS
FIRE RATING -1 HOUR
FIRE EXTINGUISHER WITH CABINET
BRACKET MOUNTED FIRE EXTINGUISHER
FE
FE
.2"36" 180
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:33 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
1/8" = 1'-0"
A003
SCHOOLBUILDING
LIFE SAFETY
BEM
MS
1/29/16
14640GILEAD
1/8" = 1'-0"A0032 MIDDLE SCHOOL LIFE SAFETY PLAN
1/8" = 1'-0"A0031 STEM BUILDING LIFE SAFETY PLAN
LIFE SAFETY LEGEND
CODE RESEARCH
BUILDING PARAMTERS
MIDDLE SCHOOL BUILDING
QUALIFICATIONS: 1. The Building is not protected by an automatic sprinkler system
USE: Educational Use
Occupancy: NFPA 101: Existing Educational Occupancy (per chapter 15)IBC: Eductaional Group E (per section 305)
Construction Type: II-B Unprotected
STEM BUILDING
QUALIFICATIONS: 1. The Building is not protected by an automatic sprinkler system
USE: Educational Use
Occupancy: NFPA 101: Existing Educational Occupancy (per chapter 15)IBC: Educational Group E (per section 305)
Construction Type: II-B Unprotected
EXISTING KITCHENTO REMAIN
EXISTING GYMNASIUMTO REMAIN
EXISTINGMULTI-PURPOSE AREA
TO REMAIN
1
1
1
2
2 3
3
3
3
3
3
33
3
3
3
3
3
4
55
6
6
6
6
7
7 7
7
7
7
7
7
1
7
8
8
7
7
7
9
9
9
9
9
99
9
10
10
10
10
10
10
10
10
11 11
12
12
12
12
12
99
9
10
9
EXISTING WALLS TO REMAIN
EXISTING CONSTRUCTION TO BE REMOVED
NOT IN SCOPE OF WORK / PHASE II CONSTRUCTION
1. DASHED LINES INDICATE EXISTING CONDITIONS TO BE REMOVED. PATCH ALL FLOORS,CEILINGS, AND WALL SURFACES AS WELL AS ALL ADJACENT SURFACES AS NECESSARYFOR THE INSTALLATION OF NEW MATERIALS - TYP.
2. DEMOLITION WORK CONSISTS OF PERFORMING ALL DEMOLITION OF ANY EXISTINGCONSTRUCTION WHICH IN ITS PRESENT FORM WILL INTERFERE WITH THE COMPLETEDNEW CONSTRUCTION AND TO PERFORM ANY OTHER CUTTING OR PATCHING OF THEEXISTING CONSTRUCTION AS SHOWN ON THE DRAWINGS.
3. DEMOLITION INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING:A. REMOVAL OF EXISTING PARTITIONS, INCLUDING DOORS, DOOR FRAMES AND GLAZED PARTITIONS AS INDICATED.B. REMOVAL OF EXISTING FLOOR COVERINGS, UNLESS NOTED OTHERWISE.C. REMOVAL OF EXISTING LIGHTS, AND MISCELLANEOUS ABANDONED ELECTRICAL ITEMS.
4. IF CONTRACTOR DISCOVERS EXISTING CONDITIONS THAT ARE NOT AS INDICATED ON THEDRAWING, HE SHALL NOTIFY THE ARCHITECT IMMEDIATELY IN WRITING BEFOREPROCEEDING WITH THAT PORTION OF THE WORK.
5. DEBRIS RESULTING FROM DEMOLITION AND CONSTRUCTION SHALL BE REMOVEDENTIRELY FROM THE BUILDING SITE ON A DAILY BASIS TO A WASTE AREA PROVIDED BYTHE CONTRACTOR.
6. ALL ELECTRICAL, TELEPHONE, DATA, AND PLUMBING ITEMS NOT TO BE REUSED SHALLBE REMOVED TO 1/2" BEHIND THE FINISHED FACE OF SURFACE. REMAINING HOLESSHALL BE CAPPED AND PATCHED TO PROVIDE A FLUSH SURFACE TO MATCH THEADJACENT SURFACE.
7. IN ALL AREAS WHERE DEMOLITION (REMOVAL OF TILE, CARPETING, TACK STRIPS,PARTITIONS, ETC.) CAUSES UNEVENESS IN SLAB OR FLOORING, THE CONTRACTORSHALL PATCH TO LEVEL THE SUB-FLOOR TO RECEIVE FINISHED FLOORING.
8. SURFACES DISTURBED BY DEMOLITION, CUTTING, PATCHING, OR IN ANY OTHER WAY,SHALL BE FINISHED TO MATCH THE EXISTING ADJACENT SURFACES IN TEXTURE ANDCOLOR. PATCHES SHALL BE IMPERCEPTIBLE.
9. WHEN DEMOLISHING GYPSUM BOARD OR PLASTER SUBSTRATE, PROVIDE A STRAIGHTEDGE PERPENDICULAR TO THE FLOOR AND PARALLEL TO THE WALLS.
10. CARE SHALL BE TAKEN IN REMOVAL OF ITEMS TO REMAIN THE OWNER'S PROPERTY TOPREVENT DAMAGE. STORE ITEMS WHERE DIRECTED BY THE OWNER. ALL OTHERMATERIALS REMOVED BY THE DEMOLITION WORK AND NOT INDICATED TO BERELOCATED OR REUSED IN THE PROJECT SHALL BECOME THE PROPERTY OF THECONTRACTOR AND REMOVED FROM THE SITE AS WORK PROGRESSES.
11. MAINTAIN BUILDING SECURITY AT ALL TIMES.
12. REFER TO SPECIFIC DRAWING FOR FURTHER NOTES THAT REFLECT INFORMATIONPERTINENT TO THAT SPECIFIC DRAWING. SEE FLOOR PLANS FOR ACTUAL FINISHEDWIDTHS OF NEW OPENINGS IN EXISTING WALLS.
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:34 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
1/8" = 1'-0"
A101
GYMNASIUMDEMOLITION
PLAN
BEM
MS
1/29/16
14640GILEAD
1/8" = 1'-0"A1011 GYMNASIUM DEMOLITION PLAN
DEMOLITION GENERAL NOTES
DEMOLITION KEY NOTES
1 REMOVE PARTITION.2 REMOVE SHOWER.3 REMOVE MARKER BOARDS AND CHALK BOARDS.4 REMOVE CABINET.5 PROVIDE NEW ROUGH OPENING FOR NEW DOOR.6 REMOVE THRU-WALL HVAC UNITS, INFILL ROUGH OPENINGS TO
MATCH EXISTING, AND PROVIDE NEW ROUGH OPENINGS FOR NEWUNITS AS REQUIRED- SEE MECH. DWGS.
7 REMOVE DOOR AND HARDWARE. FRAME TO REMAIN.8 REMOVE DOOR, FRAME, AND HARDWARE. INFILL OPENING WITH
BLOCK. FINISH TO MATCH ADJACENT CONDITIONS.9 REMOVE FLOORING AND BASE.10 REMOVE CEILING SYSTEM, LIGHT FIXTURES AND CLG. MOUNTED
DEVICES.11 REMOVE LOCKERS.12 EXISTING FIRE EXTINGUISHERS AND CABINETS TO REMAIN.
DEMOLITION LEGEND
WH
EXISTING CANOPY TOREMAIN
5 5
5
5
5
66 6
6
66
6
6 6
6
6 6
6 6 6
6 6 6 666
66
7
1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1
8 8
8
9 3 9 3
9 3
9 3
9 3
9 3
9 3 9 3 9 3 9 3
9 3
9 39 39 3
410
10 10 10 10 10 10
101010101010
11
12
12
13
13
5
14
14
1414
15 15
16 17
18 18 18
181818
18
12
19
20
1
1
1
1
1
1
2 3
32
2 3
4
4
4
1. DASHED LINES INDICATE EXISTING CONDITIONS TO BE REMOVED. PATCH ALL FLOORS,CEILINGS, AND WALL SURFACES AS WELL AS ALL ADJACENT SURFACES AS NECESSARYFOR THE INSTALLATION OF NEW MATERIALS - TYP.
2. DEMOLITION WORK CONSISTS OF PERFORMING ALL DEMOLITION OF ANY EXISTINGCONSTRUCTION WHICH IN ITS PRESENT FORM WILL INTERFERE WITH THE COMPLETEDNEW CONSTRUCTION AND TO PERFORM ANY OTHER CUTTING OR PATCHING OF THEEXISTING CONSTRUCTION AS SHOWN ON THE DRAWINGS.
3. DEMOLITION INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING:A. REMOVAL OF EXISTING PARTITIONS, INCLUDING DOORS, DOOR FRAMES AND GLAZED PARTITIONS AS INDICATED.B. REMOVAL OF EXISTING FLOOR COVERINGS, UNLESS NOTED OTHERWISE.C. REMOVAL OF EXISTING LIGHTS, AND MISCELLANEOUS ABANDONED ELECTRICAL ITEMS.
4. IF CONTRACTOR DISCOVERS EXISTING CONDITIONS THAT ARE NOT AS INDICATED ON THEDRAWING, HE SHALL NOTIFY THE ARCHITECT IMMEDIATELY IN WRITING BEFOREPROCEEDING WITH THAT PORTION OF THE WORK.
5. DEBRIS RESULTING FROM DEMOLITION AND CONSTRUCTION SHALL BE REMOVEDENTIRELY FROM THE BUILDING SITE ON A DAILY BASIS TO A WASTE AREA PROVIDED BYTHE CONTRACTOR.
6. ALL ELECTRICAL, TELEPHONE, DATA, AND PLUMBING ITEMS NOT TO BE REUSED SHALLBE REMOVED TO 1/2" BEHIND THE FINISHED FACE OF SURFACE. REMAINING HOLESSHALL BE CAPPED AND PATCHED TO PROVIDE A FLUSH SURFACE TO MATCH THEADJACENT SURFACE.
7. IN ALL AREAS WHERE DEMOLITION (REMOVAL OF TILE, CARPETING, TACK STRIPS,PARTITIONS, ETC.) CAUSES UNEVENESS IN SLAB OR FLOORING, THE CONTRACTORSHALL PATCH TO LEVEL THE SUB-FLOOR TO RECEIVE FINISHED FLOORING.
8. SURFACES DISTURBED BY DEMOLITION, CUTTING, PATCHING, OR IN ANY OTHER WAY,SHALL BE FINISHED TO MATCH THE EXISTING ADJACENT SURFACES IN TEXTURE ANDCOLOR. PATCHES SHALL BE IMPERCEPTIBLE.
9. WHEN DEMOLISHING GYPSUM BOARD OR PLASTER SUBSTRATE, PROVIDE A STRAIGHTEDGE PERPENDICULAR TO THE FLOOR AND PARALLEL TO THE WALLS.
10. CARE SHALL BE TAKEN IN REMOVAL OF ITEMS TO REMAIN THE OWNER'S PROPERTY TOPREVENT DAMAGE. STORE ITEMS WHERE DIRECTED BY THE OWNER. ALL OTHERMATERIALS REMOVED BY THE DEMOLITION WORK AND NOT INDICATED TO BERELOCATED OR REUSED IN THE PROJECT SHALL BECOME THE PROPERTY OF THECONTRACTOR AND REMOVED FROM THE SITE AS WORK PROGRESSES.
11. MAINTAIN BUILDING SECURITY AT ALL TIMES.
12. REFER TO SPECIFIC DRAWING FOR FURTHER NOTES THAT REFLECT INFORMATIONPERTINENT TO THAT SPECIFIC DRAWING. SEE FLOOR PLANS FOR ACTUAL FINISHEDWIDTHS OF NEW OPENINGS IN EXISTING WALLS.
EXISTING WALLS TO REMAIN
EXISTING CONSTRUCTION TO BE REMOVED
NOT IN SCOPE OF WORK / PHASE II CONSTRUCTION
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:35 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
1/8" = 1'-0"
A102
SCHOOLBUILDINGS
DEMOLITIONPLANS
BEM
MS
1/29/16
14640GILEAD
1/8" = 1'-0"A1022 MIDDLE SCHOOL DEMOLITION PLAN
1/8" = 1'-0"A1021 STEM BUILDING DEMOLITION PLAN
DEMOLITION GENERAL NOTES
DEMOLITION KEY NOTES
1 REMOVE THRU-WALL HVAC UNITS, INFILL ROUGH OPENINGS TOMATCH EXISTING, AND PROVIDE NEW ROUGH OPENINGS FOR NEWUNITS AS REQUIRED- SEE MECH. DWGS.
2 REMOVE FLOORING AND BASE.3 REMOVE CEILING SYSTEM, LIGHT FIXTURES AND CLG. MOUNTED
DEVICES.4 REMOVE DOOR, FRAME, AND HARDWARE.5 REMOVE PARTITION.6 REMOVE MARKER BOARDS AND CHALK BOARDS.7 PROVIDE NEW ROUGH OPENING FOR NEW DOOR.8 REMOVE DOOR AND HARDWARE. FRAME TO REMAIN.9 REMOVE FLOORING AND BASE. REMOVE MASTIC FROM FLOOR SLAB.10 REMOVE WINDOWS.11 REMOVE DOOR, FRAME, AND HARDWARE. INFILL OPENING WITH
BLOCK. FINISH TO MATCH ADJACENT CONDITIONS.12 REMOVE CANTILEVERED CANOPY.13 REMOVE TOILETS, PARTITIONS AND ACCESSORIES.14 REMOVE RESTROOM LAVATORIES.15 REMOVE LAVATORY COUNTER, MIRROR AND PAPER TOWEL
DISPENSER.16 REMOVE DRINKING FOUNTAIN.17 REMOVE BELL AND HORNS.18 REMOVE WALL MOUNTED PENCIL SHARPENERS AT CLASSROOMS.19 REMOVE FLAGPOLES AND RAISED PLANTER.20 REMOVE CANOPY SUPPORTS WHERE ROOF IS MISSING AND PATCH
CONCRETE AT SIDEWALK.
DEMOLITION LEGEND
KITCHENG106
GYMNASIUMG107
CORRIDORG110
MEN'SG111
HOME TEAMLOCKERROOMG112
HOME TEAMROOMG113
JANG114
SUPPLYG115
CLOSETG116
VISITINGTEAM ROOM
G117
CORRIDORG118 WOMEN'S
G119
VISITOR'SLOCKERROOMG120
CORRIDORG121
YOGA ROOMG124
CLASSROOMG125
CLASSROOMG126
UTILITYG127
3
A201
WEIGHTTRAINING
G123
EXISTING RAMP AEROBICEXERCISE
G122
NO SCOPE OFWORK AT THIS AREA
NO SCOPE OF WORKIN THIS AREA
EXISTING CONC.DECK TO REMAIN
NO SCOPE OF WORKAT THIS AREA
A5011
A5012
G120AG112AG112B
G122B
G123A
G122A
G122C
G123B
G124A
G121A
G125A G125BG126A
G126B
G121B
1
A201
6'-0
"
3'-8"
6'-0
"
3'-0"
3'-4"
6'-0
"
G120B
G124B
1
2
2
2
2
3
3
4
4
5
55
1
1
1
1
1
1FEC
FEC
FEC
FEC
FE
6
6
6
8
A.1
A.1
EXISTING WALLS TO REMAIN
NOT IN SCOPE OF WORK
NEW WALL CONSTRUCTION
1. SEE APPROPRIATE DRAWINGS FOR GENERAL NOTES OF ALL DISCIPLINES.
2. DO NOT SCALE DRAWINGS - USE DIMENSIONS ONLY
3. DIMENSIONS WHERE SHOWN ARE TYPICALLY GIVEN: A. TO COLUMN CENTER LINE B. TO FACE OF FINISH
4. DIMENSIONS SHOWN ON LARGER DRAWINGS GOVERN
5. FIELD VERIFY ALL EXISTING CONDITIONS
6. SEE SHEET A701 FOR WINDOW DESIGNATIONS
7. "ALIGN" AS INDICATED ON THE DRAWING SHALL BE UNDERSTOOD TO MEAN TO ALIGN THE FINISHMATERIAL OF THE WALLS OR COLUMNS INDICATED.
8. ALL INTERIOR GYPSUM BOARD SHALL BE 5/8" THICK ON METAL STUDS OR METAL FURRINGCHANNELS UNLESS OTHERWISE NOTED.
9. PROVIDE FINISHED WALLS AND FLOORING UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK.
10. SEE SHEET A601 FOR PARTITION TYPES. PROVIDE CEMENTITIOUS BACKER BOARD BEHIND ANYNEW TILED SURFACES ON METAL STUD FRAMING.
11. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL OR PLUMBING ITEMS PENETRATEPARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDEADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS AND SMOKE BARRIERSSHALL BE SEALED WITH APPROPRIATE FIRE STOP MATERIAL TO PROVIDE FIRE, SMOKE AND/ORACOUSTIC ISOLATION OF SPACES.
12. ALL INTERIOR AND EXTERIOR WOOD BLOCKING SHALL BE TREATED AS INDICATED INSPECIFICATIONS.
13. ALL GYPSUM BOARD PARTITIONS TO HAVE LEVEL 4 FINISH.
14. DOORS WITHOUT DESIGNATION SYMBOL ARE EXISTING TO REMAIN.
15. BUILDING EXTERIOR TO RECEIVE PRIME AND PAINT. BRICK VENEER TO REMAIN UNPAINTED.
16. ALL EXISTING FIXTURES AND EQUIPMENT ARE TO REMAIN UNLESS NOTED OTHERWISE.
?S1
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:36 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
1/8" = 1'-0"
A103
GYMNASIUMFLOOR PLAN
BEM
MS
1/29/16
14640GILEAD
1/8" = 1'-0"A1031 GYMNASIUM FLOOR PLAN
FLOOR PLAN GENERAL NOTES
FLOOR PLAN KEY NOTES
1 MODIFY EXISTING ROUGH OPENINGS AND INSTALL NEW THRU-WALLHVAC UNITS- SEE MECH. DWGS.
2 INFILL FORMER DOOR OPENING WITH CONCRETE BLOCK TO MATCHEXISTING WALL.
3 PATCH, PRIME AND PAINT WALL IN AREA AT REMOVAL OF WALLLOCATION.
4 PATCH SUB FLOOR AT DEMOLISHED PARTITION.5 PROVIDE SLOPED TRANSITION AT EDGE OF EXISTING SPORTS
FLOORING.6 INSTALL NEW 96" X 48" WHITEBOARD WITH SILL AT 36" AFF.
FLOOR PLAN LEGEND
WH
CLASSROOMM101
ELECM102
UTILITYM103
JANM104
CORRIDORM105
WORKROOMM106
RESOURCEROOMM107
CLASSROOMM108
CORRIDORM109
CLASSROOMM110
CLASSROOMM111
BOYSM112
GIRLSM113
CLASSROOMM116
COVEREDCANOPY TO REMAIN
H/CRESTROOM
M114
CLOSETM115
1
A202
4
A2023
A202
2
A202
M115
M114
M105
M101
M116
M113
M103M104
M107B
M107A
M110M111M112
A5013
M109A
M109B M109C
A1043
?1?1 ?1 ?1 ?1
?1?1?1?1
M106
NEWFEC
1 1
1 1 1 1
1 1 1
?2 ?2
?3
2
34
5 5
6 6 6 6
6666 6
7
8
9 9 99
9999
2A601
?4 ?4
M108
C.1
3A601
3A601
CLASSROOMS101
CLOSETS102
SCIENCELABS103
CLASSROOMS104
MENSS105
WOMENSS106ELECT
S107
7
A202
8
A202
6
A202
S104
S103A
S101
5
A202
1
1
1
10 10
11
11
11
12
11
13
13
13
EXISTING WALLS TO REMAIN
NOT IN SCOPE OF WORK
NEW WALL CONSTRUCTION
1. SEE APPROPRIATE DRAWINGS FOR GENERAL NOTES OF ALL DISCIPLINES.
2. DO NOT SCALE DRAWINGS - USE DIMENSIONS ONLY
3. DIMENSIONS WHERE SHOWN ARE TYPICALLY GIVEN: A. TO COLUMN CENTER LINE B. TO FACE OF FINISH
4. DIMENSIONS SHOWN ON LARGER DRAWINGS GOVERN
5. FIELD VERIFY ALL EXISTING CONDITIONS
6. SEE SHEET A701 FOR WINDOW DESIGNATIONS
7. "ALIGN" AS INDICATED ON THE DRAWING SHALL BE UNDERSTOOD TO MEAN TO ALIGN THE FINISHMATERIAL OF THE WALLS OR COLUMNS INDICATED.
8. ALL INTERIOR GYPSUM BOARD SHALL BE 5/8" THICK ON METAL STUDS OR METAL FURRINGCHANNELS UNLESS OTHERWISE NOTED.
9. PROVIDE FINISHED WALLS AND FLOORING UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK.
10. SEE SHEET A601 FOR PARTITION TYPES. PROVIDE CEMENTITIOUS BACKER BOARD BEHIND ANYNEW TILED SURFACES ON METAL STUD FRAMING.
11. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL OR PLUMBING ITEMS PENETRATEPARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDEADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS AND SMOKE BARRIERSSHALL BE SEALED WITH APPROPRIATE FIRE STOP MATERIAL TO PROVIDE FIRE, SMOKE AND/ORACOUSTIC ISOLATION OF SPACES.
12. ALL INTERIOR AND EXTERIOR WOOD BLOCKING SHALL BE TREATED AS INDICATED INSPECIFICATIONS.
13. ALL GYPSUM BOARD PARTITIONS TO HAVE LEVEL 4 FINISH.
14. DOORS WITHOUT DESIGNATION SYMBOL ARE EXISTING TO REMAIN.
15. BUILDING EXTERIOR TO RECEIVE PRIME AND PAINT. BRICK VENEER TO REMAIN UNPAINTED.
16. ALL EXISTING FIXTURES AND EQUIPMENT ARE TO REMAIN UNLESS NOTED OTHERWISE.
?S1
4'-0
"
8'-0"
6" CMU BLOCK
BRICK VENEEER
R11'-4"
LINE OF EXISTINGCANOPY ABOVE
1A601
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:37 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
As indicated
A104
SCHOOLBUILDINGS
FLOORPLANS
BEM
MS
1/29/16
14640GILEAD 1/8" = 1'-0"A104
1 MIDDLE SCHOOL FLOOR PLAN 1/8" = 1'-0"A104
2 STEM BUILDING FLOOR PLAN
FLOOR PLAN GENERAL NOTES
FLOOR PLAN KEY NOTES
FLOOR PLAN LEGEND
1 INSTALL NEW THRU-WALL HVAC UNITS- SEE MECH. DWGS.2 NEW DOOR AND FRAME AT ENLARGED OPENING.3 PROVIDE NEW BRICK SURROUNDS WITH CAST STONE CAPS AT
EXISTING COVERED CANOPY COLUMNS.4 INSTALL NEW ALUMINUM GUARDRAIL.5 INSTALL NEW CANOPIES- SEE ROOF PLAN.6 INSTALL NEW EXTERIOR WINDOW. INFILL AREA BELOW WINDOW
STUCCO OVER CONCRETE BLOCK.7 PATCH ASPHALT AFTER REMOVING PLANTER.8 NEW GYPSUM BOARD OVER METAL STUD BULKHEAD AT 8'-0" AFF.9 INSTALL NEW 96" X 48" WHITEBOARD WITH SILL AT 36" AFF.10 PRIME AND PAINT EXISTING SHELVING.11 EXISTING COUNTERS, EQUIPMENT, LAB TABLES AND SINKS TO
REMAIN.12 PRIME AND PAINT EXISTING BASE CABINET.13 EXISTING MARKER BOARDS TO REMAIN.
1/2" = 1'-0"A1043 MIDDLE SCHOOL COLUMN WRAP
TYP.
PROVIDE NEW MECHANICALLYATTACHED PVC ROOFING ON 1/2"GYPSUM SHEATHING AND 1-1/2"
RIGID INSULATION OVER EXISTINGSTANDING SEAM ROOF
SLOPE SLOPE SLOPE SLOPE
SLOPE
EXISTING BUILT-UPROOFING TO REMAIN
PROVIDE NEW METALFASCIA WITH COUNTER-FLASHING INTO EXISTINGMETAL GUTTER SYSTEM
REPLACE EXISTING WITHNEW METAL RAKE TRIM
REPLACE EXISTING WITHNEW METAL RAKE TRIM
REPLACE EXISTING WITHNEW METAL RAKE TRIM
PROVIDE NEW METALFASCIA INTO EXISTINGMETAL GUTTER
PROVIDE NEW METAL FASCIA WITHCOUNTERFLASHING INTO EXISTINGMETAL GUTTER SYSTEM
PROVIDE NEW METAL FASCIA WITHCOUNTERFLASHING INTO EXISTINGMETAL GUTTER SYSTEM
PROVIDE NEW MECHANICALLYATTACHED PVC ROOFING ON 1/2"GYPSUM SHEATHING AND 1-1/2"
RIGID INSULATION OVER EXISTINGSTANDING SEAM ROOF
PROVIDE NEW MECHANICALLYATTACHED PVC ROOFING ON 1/2"GYPSUM SHEATHING AND 1-1/2"
RIGID INSULATION OVER EXISTINGSTANDING SEAM ROOF
PROVIDE NEW MECHANICALLYATTACHED PVC ROOFING ON 1/2"GYPSUM SHEATHING AND 1-1/2"
RIGID INSULATION OVER EXISTINGSTANDING SEAM ROOF
PROVIDE NEW MECHANICALLYATTACHED PVC ROOFING ON 1/2"GYPSUM SHEATHING AND 1-1/2"
RIGID INSULATION OVER EXISTINGSTANDING SEAM ROOF
PROVIDE NEW METALFASCIA WITH COUNTER-FLASHING INTO EXISTINGMETAL GUTTER SYSTEM
REMOVE EXISTING BUILT-UPROOFING AND PROVIDE NEWMECHANICALLY ATTACHED PVCMEMBRANE ROOFING OVER 1/2"GYPSUM SHEATHING AND 4" OFTAPERED RIGID INSULATION ASREQUIRED TO SLOPE TO REAR OFBUILDING
PROVIDE NEW PREFINALUM. 6" X 6" GUTTER ANDDOWNSPOUTS AT WESTSIDE OF BUILDING
REMOVE EXISTING FASCIA ANDPROVIDE NEW PREFIN. ALUMFASCIA AROUND ENTIREBUILDING PERIMETER
SLOPE
SLOPE
SLOPE
NOTE: ROOF AT MIDDLESCHOOL BUILDING IS TOREMAIN. PROVIDE NEWPREFABRICATEDCANOPIES AT EAST ANDWEST DOORWAYS- SEESHEET A202
EXISTING PIPE
DRAW BAND
PVC MEMBRANE
STRETCH PVC DETAILMEMBRANE TO FORMEXISTING PIPE DIA.
PVC MEMBRANEOVER ADHESIVE
CONTINUOUSWELD
FASTNER AND PLATEAROUND PIPE VENT
PVC MEMBRANEADHESIVE
SINGLE PLY CAULK
EXISTING ROOF DECK
4" X 5" PREFIN. METALGUTTER AND DOWNSPOUTS
PREFIN. METALGRAVEL STOP
P.T. 2X WOOD NAILER
HEAT WELDED ROOFSYSTEM FLASHING STRIP
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:39 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
As indicated
A105
GYMNASIUMAND STEMBUILDING
ROOF PLANS
BEM
MS
1/29/16
14640GILEAD
1/8" = 1'-0"A1051 GYMNASIUM ROOF PLAN
1/8" = 1'-0"A1052 STEM BUILDING ROOF PLAN
6" = 1'-0"A1054 PIPE VENT PENETRATION DETAIL
3" = 1'-0"A1053 GUTTER DETAIL
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 3:28:17 PMC:\Users\brucem\Documents\Gilead Church DD Central File_brucem.rvt
1/8" = 1'-0"
A106
FORMERCHURCH
ROOF PLAN
BEM
BEM
1/29/16
14640GILEAD
1/8" = 1'-0"A1061 ROOF PLAN
PROVIDE NEW MECHANICALLYATTACHED PVC ROOFING ON
1/2" GYPSUM SHEATHING AND1-1/2" RIGID INSULATION OVER
EXISTING METAL ROOFING
PROVIDE NEW MECHANICALLYATTACHED PVC ROOFING ON
1/2" GYPSUM SHEATHING AND1-1/2" RIGID INSULATION OVER
EXISTING METAL ROOFING
PROVIDE NEW MECHANICALLYATTACHED PVC ROOFING ON
1/2" GYPSUM SHEATHING AND1-1/2" RIGID INSULATION OVER
EXISTING METAL ROOFING
REMOVE EXISTING BUILT-UPROOFING AND REPLACE WITHNEW PVC ROOFING OVER 4"
RIGID INSULATION TO FOLLOWEXISTING LOW SLOPE
REPLACE EXISTINGMETAL GUTTER ANDDOWNSPOUTS TOMATCH EXISTING
PROVIDE NEW PVC ROOFING OVER1/2" SUBSTRATE ON 1-1/2" RIGIDINSULATION OVER CORR. METALDECK ON LIGHT GAGE STEELFRAMING AT NEW CRICKETS
EXISTNG METAL SCREENTO REMAIN
EXISTING METALCANOPY TO REMAINEXISTING METAL
CANOPY TO REMAIN
EXISTNG METAL SCREENTO REMAIN
5:12
3.5:12 3.5:12
5:12 1:12
1:12
1:12
REPLACE EXISTINGMETAL GUTTER ANDDOWNSPOUTS TOMATCH EXISTING
-2'-8"Gymnasium Floor
-1'-8"Gym Lobby Floor
NEW METAL FASCIA AND COUNTER- FLASHINGINTO EXISTING GUTTER SYSTEM- EXISTINGGUTTERS AND DOWNSPOUTS TO REMAIN
NEW PVC ROOFING OVER 1/2"GYP. SHEATHIMG AND 1-1/2"RIGID INSUL. OVER EXISTINGMETAL ROOFING
EXISTING PRE-ENGINEERED METALBUILDING PANELS- PRIME AND PAINT
EXISTING CONC. BLOCK-PRIME AND PAINT
NEW H.M. DOOR INEXISTING H.M. FRAMES-PRIME AND PAINT- TYP.
NEW THRU-WALL HVAC UNITS-SEE MECH DWGS. MODIFYEXISTING ROUGH OPENINGSAS REQ'D FOR NEW UNITS
NEW H.M. DOOR INEXISTING H.M. FRAMES-PRIME AND PAINT- TYP.
-2'-8"Gymnasium Floor
-1'-8"Gym Lobby Floor
PROVIDE NEW PREFIN. METALRAKE OVER EXISTING- TYP.
EXISTING ALUM. STOREFRONTDOORS TO REMAIN
EXISTING ALUM. STOREFRONTDOORS TO REMAIN
EXISTING ALUM. STOREFRONTDOORS TO REMAIN
NEW STOREFRONT DOORS INEXISTING FRAME
EXISTING PRE-ENGINEERED METALBUILDING PANELS- PRIME AND PAINT
EXISTING PRE-ENGINEERED METALBUILDING PANELS- PRIME AND PAINT
EXISTING BRICK VENEERTO REMAIN EXISTING BRICK VENEER
TO REMAIN
NOTE: EXSITING METALSIDEWALK CANOPIES ATGYMNASIUM AND STEMBUILDING ARE TO REMAIN
PROVIDE NEW PREFIN. METALRAKE OVER EXISTING- TYP.
EXISTING PRE-ENGINEEREDMETAL BUILDING PANELS-PRIME AND PAINT
EXISTING CONC. BLOCKAT HVAC AREA TOREMAIN UNPAINTED
EXISTING CONC. BLOCK-PRIME AND PAINT
EXISTING CONC. BLOCK-PRIME AND PAINT
NEW H.M DOORSADD FRAME IN EXISTINGOPENING- PRIME AND PAINT
EXISTING CONC. BLOCK-PRIME AND PAINT
EXISTING PRE-ENGINEEREDMETAL BUILDING PANELS-PRIME AND PAINT
EXISTING H.M. DOORS ANDFRAME- PRIME AND PAINT
EXISTING H.M. DOORAND FRAME- PRIMEAND PAINT
EXISTING LOUVERED VENTS ANDHVAC DUCTWORK TO REMAIN- TYP.
EXISTING ELECTRICALDISCONNECT TO REMAIN
-1'-8"Gym Lobby Floor
EXISTING PRE-ENGINEERED METALBUILDING PANELS- PRIME AND PAINT
EXISTING CONC. BLOCK-PRIME AND PAINT
EXISTING PRE-ENGINEERED METALBUILDING PANELS- PRIME AND PAINT
NEW PVC ROOFING OVER 1/2" GYP.SHEATHIMG AND 1-1/2" RIGID INSUL.OVER EXISTING METAL ROOFING
NEW METAL FASCIA AND COUNTER-FLASHING INTO EXISTING GUTTERSYSTEM- EXISTING GUTTERS ANDDOWNSPOUTS TO REMAIN
EXISTING CONC. BLOCKBEYOND- PRIME AND PAINT EXISTING H.M. DOORS
AND FRAME TO REMAIN-PRIME AND PAINT
EXISTING ELECTRICALPANEL TO REMAIN
NEW H.M. DOORIN EXISTING FRAME -PRIME AND PAINT
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:40 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
1/8" = 1'-0"
A201
GYMNASIUMEXTERIOR
ELEVATIONS
BEM
MS
1/29/16
14640GILEAD
1/8" = 1'-0"A2014 GYMNASIUM EAST ELEVATION
1/8" = 1'-0"A2011 GYMNASIUM SOUTH ELEVATION
1/8" = 1'-0"A2013 GYMNASIUM NORTH ELEVATION
1/8" = 1'-0"A2012 GYMNASIUM WEST ELEVATION
EXTERIOR FINISH GENERAL NOTES
1. ELASTOMERIC COATING AT EXISTING METAL CANOPY, EXISTING CONCRETE BLOCK,CONCRETE BLOCK INFILL AND SOFFITS TO MATCH SHERWIN-WILLIAMS SE 6349 PENNYWISE.
2. PAINT AT SOFFIT OF EXISTING PRE-ENGINEERED BUILDING METAL PANELS IS TO MATCHEXISTING.
3. PAINT AT NEW AND EXISTING HOLLOW METAL FRAMES AND DOORS IS TO MATCHSHERWIN-WILLIAMSSW 6349 PENNYWISE
0"STEM Floor
BRICK VENEER COLUMNCOVERS WITH 6" CASTSTONE CAP
NEW ALUMINUM RAILINGBETWEEN PIERS
EXISTING CORRUGATED METALCANOPY- PRIME AND PAINT
NEW ALUM. STOREFRONTENTRANCE DOOR IN ALUM.FRAME
NEW INSUL. GLASS WINDOWS INALUM. FRAMING SYSTEMS ATEXISTING OPENINGS- INFILL LOWERPORTION OF EXISTING OPENINGSWITH STUCCO OVER CONC. BLOCKWITH ELASTOMERIC COATING- TYP.EXISTING BRICK VENEER TO REMAIN
EXISTING ROOFING ANDFASCIA TO REMAIN- PRIMEAND PAINT 2X WOOD FASCIA
EXISTING STEEL COLUMN-PRIME AND PAINT
6"8'
-4"
6"8'
-4"
INFILL BRICK VENEER OVERCONC. BLOCK TO MATCHEXISTING AFTER REMOVINGTHRU-WALL HVAC UNITS- TYP.
NEW THRU-WALL HVAC UNITS-SEE MECH DWGS- TYP.
2A601
0"STEM Floor
NEW PREFABRICATEDCANOPY AT EGRESSDOORS
EXISTING CORRUGATED METALCANOPY- PRIME AND PAINT
BRICK VENEERCOLUMN COVER WITH6" CAST STONE CAP
NEW H.M DOORSAND FRAME INEXISTING OPENING-PRIME AND PAINT
EXISTING STEEL COLUMN-PRIME AND PAINT
PRIME AND PAINT EXISTING2X WOOD FASCIA
3A601
0"STEM Floor
EXISTING METALCANOPY- PRIMEAND PAINT
BRICK VENEERCOLUMN COVERWITH 6" CASTSTONE CAP
EXISTING STEELCOLUMN- PRIMEAND PAINT
NEW PREFABRICATEDCANOPY AT EGRESS DOORS
NEW H.M. DOORS ANDFRAME IN EXISTINGOPENING- PRIME AND PAINT
PRIME AND PAINTEXISTING 2X WOODFASCIA
3A601
0"STEM Floor
EXISTING CORRUGATEDMETAL CANOPY BEYOND-PRIME AND PAINT
NEW INSUL. GLASS IN ALUM. FRAMEWINDOWS AT EXISTING OPENINGSINFILL LOWER PORTION OF EXISTINGOPENINGS WITH STUCCO OVERCONC. BLOCK WITH ELASTOMERICCOATING- TYP.
NEW H.M. DOOR AND FRAME-PRIME AND PAINT
EXISTING H.M. DOORS ANDFRAME TO REMAIN-PRIME AND PAINT
NEWPREFABRICATEDCANOPY
NEWPREFABRICATEDCANOPY
EXISTING FASCIA, GUTTERAND DOWNSPOUTS TO REMAIN-REPAINT 2X WOOD FASCIA
INFILL ROUGH OPENING WITHBRICK VENEER OVER CONC.BLOCK TO MATCH EXISTINGAFTER REMOVING EXISTINGMECH. THRU-WALL UNITS- TYP.
2A601
NEW CONC. STAIRSAND STOOP
0"STEM Floor -1'-8"
Gym Lobby FloorNEW H.M. DOOR AND FRAMEIN EXISTING OPENING-PRIME AND PAINT
NEW H.M. DOORS ANDFRAMES IN EXISTINGOPENING- PRIME AND PAINT
PRIME AND PAINT EXISTING2X WOOD FASCIA
EXISTING BRICKVENEER TO REMAIN
EXISTING CANOPYTO REMAIN
-1'-8"Gym Lobby Floor
EXISTING H.M. DOORS AND FRAMESTO REMAIN- PRIME AND PAINT
EXISTING WINDOWS TO REMAINPRIME AND PAINT EXISTING2X WOOD FASCIA
EXISTING BRICKVENEER TO REMAIN
0"STEM Floor-1'-8"
Gym Lobby Floor
EXISTING H.M. DOOR ANDFRAME- PRIME AND PAINT
EXISTING BRICK VENEERTO REMAIN
PROVIDE NEW PREFIN ALUM. 6" X 6"GUTTER AND DOWNSPOUTS
PRIME AND PAINT EXISTING2X WOOD FASCIA
0"STEM Floor
PRIME AND PAINT EXISTING2X WOOD FASCIA
EXISTING BRICKVENEER TO REMAIN
EXISTING CANOPYTO REMAIN
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:42 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
1/8" = 1'-0"
A202
SCHOOLBUILDINGSEXTERIOR
ELEVATIONS
BEM
MS
1/29/16
14640GILEAD
1/8" = 1'-0"A2021 MIDDLE SCHOOL SOUTH ELEVATION
1/8" = 1'-0"A2023 MIDDLE SCHOOL WEST ELEVATION
1/8" = 1'-0"A2024 MIDDLE SCHOOL EAST ELEVATION
1/8" = 1'-0"A2022 MIDDLE SCHOOL NORTH ELEVATION
1/8" = 1'-0"A2025 STEM BUILDING EAST ELEVATION
1/8" = 1'-0"A2026 STEM BUILDING NORTH ELEVATION
1/8" = 1'-0"A2027 STEM BUILDING WEST ELEVATION
1/8" = 1'-0"A2028 STEM BUILDING SOUTH ELEVATION
EXTERIOR FINISH GENERAL NOTES
1. BRICK AT COLUMN COVERS IS TO BE CHEROKEE BRICK DIXIE ROSE MODULAR.
2. REUSE OR PROVIDE NEW BRICK TO MATCH EXISTING AT HVAC UNIT INFILL.
3. ELASTOMERIC COATING AT WINDOW INFILL AND PAINT AT EXISTING CANOPY, HOLLOWMETAL DOORS AND FRAMES, EXPOSED STEEL FRAMING AND FASCIA TO MATCHSHERWIN-WILLIAMS SE 6349 PENNYWISE.
4. PAINT AT SOFFIT OF EXISTING CANOPY TO MATCH BENJAMIN MOORE OC-65 CHANTILLY LACE
A 24" X 24" ACOUSTIC CEILING TILE
B 1/2" GYPSUM BOARD; SCHEDULED PAINT
C EXISTING CEILING TO REMAIN
A1'-0"
CEILING HEIGHTABOVE FINISH FLOOR
CEILING TYPE
RECESSED LIGHT FIXTURE
WALL SCONCE
2X2 OR 2X4 FLUORESCENT LAY-IN LIGHT FIXTURE
PROJECTOR; REFER TO ELECTRICAL
EXIT SIGNS; BLACK QUADRANT REPRESENTS ILLUMINATEDFACE OF SIGN
P
MECHANICAL DIFFUSERS
MECHANICAL RETURN AIR GRILLE
3
A201A9'-0"
A9'-0"
A9'-0"
A9'-0"
A10'-0"
A9'-0"A10'-0"
A9'-0"
A10'-0"
A10'-0" A9'-0"
A9'-0"
A9'-0"
A9'-0"
A9'-0"
A9'-0"
C
NO SCOPE OFWORK AT THIS AREA
NO SCOPE OF WORKIN THIS AREA
PHASE IICONSTRUCTION
C C
GYP. BOARDBULKHEAD AT 9'-0"A.F.F. -TYP.
SLOPING GYP.BOARD BULKHEAD FROM9'-8" TO 7'-8" AFF -TYP.SEE 2/A301
2A301
2A301
Sim
GYP. BOARDBULKHEAD AT 9'-0"A.F.F. -TYP.
SLOPING GYP.BOARD BULKHEAD FROM9'-8" TO 7'-8" AFF -TYP.
8
EXISTING WALLS TO REMAIN
NOT IN SCOPE OF WORK / PHASE II CONSTRUCTION
5/8" GYPSUM BOARD WITHSCHEDULED FINISH ON3-5/8" METAL FRAMING AT16" O.C., TYP.
EXTEND GYPSUM BOARD 6"ABOVE CEILING- TYP.
SUSPENDED CEILING;REFER TO RCP, TYP.
REFER TO RCP'S
REFER TO RCP'S
1'-0
"
BULK
HEA
D A
.F.F
.9'
-0"
BULKHEAD TO UNDERSIDEOF STRUCTURE- PAINT PNT-1
ACUOUSTIC CEILING TILEWITH LAY-IN LIGHT FIXTURES
SLOPING BULKHEADBEYOND- PAINT TOMATCH ACCENTCOLOR AT ROOM
A3013
9'-8
"
7'-8
"
22'-5"3'-4"
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:43 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
As indicated
A301
GYMNASIUMBUILDINGCEILING
PLAN
BEM
MS
1/29/16
14640GILEAD
CEILING GENERAL NOTES
CEILING LEGEND
CEILING TYPES
1. CONTRACTOR TO SCHEDULE CEILING CAVITY COORDINATION MEETING WITH ALLSUBCONTRACTORS AND ARCHITECT PRIOR TO INSTALLING ANY COMPONENTS.
2. CENTER LIGHT FIXTURES WITHIN CEILING TILES AND GYPSUM BOARD SOFFITS INBOTH DIRECTIONS UNLESS NOTED OTHERWISE.
3. NOT USED.
4. REFER TO ELECTRICAL FOR AUDIO/VISUAL ROUGH-IN TO BE INSTALLED BY G.C.
5. PROVIDE AND INSTALL ACCESS PANELS IN GYPSUM BOARD CEILINGS ASNEEDED TO ACCESS ABOVE CEILING EQUIPMENT. G.C. TO REVIEW LOCATIONS WITHARCHITECT PRIOR TO INSTALLATION. ACCESS PANELS SHALL BE PROTECTED ASAPPROPRIATE FOR THE FIRE RESISTANCE RATING OF THE BARRIER.
6. EXTERIOR FIXTURES AND INSTALLATION SHALL BE WATERTIGHT.
7. PROVIDE ACCESS DOORS AT ALL LOCATIONS INDICATED OR REQUIRED FORACCESS TO EQUIPMENT, VALVES, JUNCTION BOXES, ETC.
8. PROVIDE CORNER BEADS, J BEADS AND OTHER GYPSUM BOARD ACCESSORIESAT ALL EXPOSED CORNERS, UNLESS NOTED OTHERWISE.
9. REFER TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE TYPES.
1/8" = 1'-0"A3011 GYMNASIUM REFLECTED CEILING PLAN
1 1/2" = 1'-0"A3013 BULKHEAD DETAIL
1/4" = 1'-0"A3012 SECTION @CEILING HEIGHT CHANGE
A8'-6"
C
C
C
A8'-6"
A8'-6" A8'-6" A8'-6" A8'-6"
A8'-6"A8'-6"
A8'-6"A8'-6"
A8'-6"
A8'-6"
A8'-6"
PRIME AND PAINT EXISTINGCORRUGATED METALCANOPY SOFFIT
NEW SURFACE MOUNTEDSECURITY LIGHTING
EXSITING SECURITYSCONCES TO REMAIN
EQ EQ6'-0"
GYP. BOARD BULKHEAD AT 8'-0" AFF
3A601
EQ6'
-0"
EQ
A8'-6"
A8'-6"
A8'-6"
A8'-6"
NOT IN SCOPEOF WORK
A1'-0"
CEILING HEIGHTABOVE FINISH FLOOR
CEILING TYPE
RECESSED LIGHT FIXTURE
WALL SCONCE
2X2 OR 2X4 FLUORESCENT LAY-IN LIGHT FIXTURE
PROJECTOR; REFER TO ELECTRICAL
EXIT SIGNS; BLACK QUADRANT REPRESENTS ILLUMINATEDFACE OF SIGN
P
MECHANICAL DIFFUSERS
MECHANICAL RETURN AIR GRILLE
A 24" X 24" ACOUSTIC CEILING TILE
B 1/2" GYPSUM BOARD; SCHEDULED PAINT
C EXISTING CEILING TO REMAIN
EXISTING WALLS TO REMAIN
NOT IN SCOPE OF WORK / PHASE II CONSTRUCTION
BEAM
CONNECTED ALUMINUMFABRICATIONS
3/8" ANCHOR ROD
EPXOY ANCHORING SYSTEM
EXTRUDED ALUMINUMROOF DECKING
FLASHING1/4" TAPCON
EXISTING CMU WALL WITHBRICK VENEER FINISH
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:44 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
As indicated
A302
SCHOOLBUILDINGS
CEILINGPLANS
BEM
MS
1/29/16
14640GILEAD
1/8" = 1'-0"A3022 MIDDLE SCHOOL REFLECTED CEILING PLAN
1/8" = 1'-0"A3021 STEM BUILDING REFLECTED CEILING PLAN
1. CENTER FIRE SPRINKLER HEADS ON CEILING TILE (TYP.). COORDINATE ENTIRE FIRESPRINKLER LAYOUT AND DRAIN PIPE LOCATION WITH ARCHITECT.
2. CONTRACTOR TO SCHEDULE CEILING CAVITY COORDINATION MEETING WITH ALLSUBCONTRACTORS AND ARCHITECT PRIOR TO INSTALLING ANY COMPONENTS.
3. CENTER LIGHT FIXTURES WITHIN CEILING TILES AND GYPSUM BOARD SOFFITS INBOTH DIRECTIONS, UNLESS NOTED OTHERWISE.
4. NOT USED.
5. REFER TO ELECTRICAL FOR AUDIO/VISUAL ROUGH-IN TO BE INSTALLED BY G.C.
6. PROVIDE AND INSTALL ACCESS PANELS IN GYPSUM BOARD CEILINGS ASNEEDED TO ACCESS ABOVE CEILING EQUIPMENT. G.C. TO REVIEW LOCATIONS WITHARCHITECT PRIOR TO INSTALLATION. ACCESS PANELS SHALL BE PROTECTED ASAPPROPRIATE FOR THE FIRE RESISTANCE RATING OF THE BARRIER.
8. EXTERIOR FIXTURES AND INSTALLATION SHALL BE WATERTIGHT.
9. EMERGENCY LIGHT FIXTURES SHALL BE PROVIDED AS REQUIRED BY CODE.
10. PROVIDE ACCESS DOORS AT ALL LOCATIONS INDICATED OR REQUIRED FORACCESS TO EQUIPMENT, VALVES, JUNCTION BOXES, ETC.
11. PROVIDE CORNER BEADS, J BEADS AND OTHER GYPSUM BOARD ACCESSORIESAT ALL EXPOSED CORNERS, UNLESS NOTED OTHERWISE.
12. REFER TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE TYPES.
CEILING GENERAL NOTES
CEILING LEGEND
CEILING TYPES
REFLECTED CEILING PLAN KEYNOTES
3" = 1'-0"A3023 CANOPY WALL CONNECTION DETAIL
1. ALL FINISHES AND MATERIALS SHALL BE AS INDICATED IN THE FINISH LEGEND. NO SUBSTITUTIONS WILL BE ACCEPTEDWITHOUT PRIOR APPROVAL BY THE ARCHITECT.
2. UNLESS OTHERWISE NOTED, ALL EXISTING GYPSUM BOARD AND CMU WALLS IN AFFECTED AREAS ARE TO REPAINTED. ALLPAINT COLOR THROUGHOUT IS TO BE PNT-1.
3. UNLESS OTHERWISE NOTED, ALL EXISTING AND NEW GYP. BD. CEILINGS AND BULKHEADS IN AFFECTED AREAS ARE TO BEPAINTED PNT-2, FLAT FINISH.
4. ALL H.M. FRAMES AND TRIM IN AFFECTED AREAS ARE TO BE PAINTED PNT-3, GLOSS FINISH U.N.O.
6. WHERE SEAMS IN FLOORING MATERIALS OCCUR AT DOORS, THEY SHALL BE PARALLEL WITH THE DOOR IN THECLOSED POSITION AND CENTERED ON THE THICKNESS OF THE DOOR UNLESS INDICATED OTHERWISE BY NOTE ON THEFINISH PLAN.
7. RESILIENT FLOORING SHALL BE VINYL COMPOSITION TILE 12" x 12" x 1/8" THICK. WHERE FLOORING MATERIALS OFDIFFERING THICKNESS (TILE TO VCT) INTERSECT, PROVIDE TILE TRANSITION ACCESSORIES AS REQUIRED.
8. ALL FINISHES ARE TO BE SUBMITTED TO ARCHITECT PRIOR TO INSTALLATION FOR APPROVAL. SUBMITTAL TO BE ASSPECIFIED IN THE PROJECT MANUAL, AND ARE NOT TO BE SMALLER THAN 12" X 12". PROVIDE A MINIMUM OF TWOSAMPLES PER FINISH IN SUBMITTAL.
9. ALL SURFACES WHICH ARE TO RECEIVE A FINISH APPLICATION SHALL BE COMPLETELY SMOOTH.
10. ALL VCT SHALL BE ADHERED DIRECTLY TO THE SUB-FLOOR WITH ADHESIVE COMPATIBLE TO THE VCTMANUFACTURER'S RECOMMENDED SPECIFICATIONS.
11. AT TRANSITIONS FROM VCT TO RUBBER FLOORING; PROVIDE VINYL TRANSITION ACCESSORIES AS REQUIRED.
12. FURNISH AND INSTALL CONTINUOUS ROLL RUBBER BASE. WRAP BASE AT CASED OPENINGS AND STUB WALLS.
13. ALL WINDOW SILLS TO BE SS-1.
14. PROVIDE SCHLUTER COVE TRANSITION TRIM WHERE WALL TILE OR TILE BASE MEET FLOOR TILE; DILEX-HKU, STAINLESSSTEEL.
FINISH NOTES
SYMBOL DESCRIPTION/TYPE STYLE/COLOR REMARKS
RB-1 EXPANCORUBBER FLOOR
PT-1 CERAMIC TECHNICSPORCELAIN TILE 6X24
FLOOR
STYLE: REZTEC 8MMCOLOR: JET RED
PNT 1
PNT 2
PNT 3
WALLS
COLOR: GENTLE CREAM OC-96
B 1
B 2
ALLSTATE4" CONT. RUBB. COVE BASE
BASE
CERAMIC TECHNICS3 X 12 BULLNOSE BASE
COLOR: D49
STYLE: STUDIO MARMI LIMESTONECOLOR: MOCHA BROWN HONED
COLOR: CHANTILLY LACE OC-65
COLOR: SW7018 DOVETAIL
PNT 4 COLOR: SILKEN BLUE CSP-670
FINISH LEGEND
CHANGE IN FLOORMATERIAL
CONTROL JOINT
CONCRETE SAW CUT
STYLE: STUDIO MARMI WOOD GRAINCOLOR: GRIGIO
RF-1 STYLE: XCRCOLOR: GRAVEL
EXPANCORESILIENT FLOORING
VCT-1 STYLE: PROGRESSIONSCOLOR: WHEAT 551123
FEILD PAINT
GYPSUM CEILING PAINT
HOLLOW METAL AND TRIM PAINT
ACCENT WALL PAINT
MANNINGTONVINYL COMPOSITION TILE
PT-1 TRINITY TILEPORCELAIN TILE 12X12
STYLE: ARGONITECOLOR: EARTH MATTE
B 3CERAMIC TECHNICS3 X 12 BULLNOSE BASE
STYLE: CTL METROPOLISCOLOR: MOCHA
CONTACT: NICOLE HIGGINS 770.740.0050 X224
CONTACT: NICOLE HIGGINS 770.740.0050 X224
CONTACT: NICOLE HIGGINS 770.740.0050 X224
CONTACT: ELIZABETH CHAMBLEY 770.856.5139
CONTACT:CHRISTINE LAKSO 404.803.8907
VCT-2 STYLE: PROGRESSIONSCOLOR: BRONZE 55246
MANNINGTONVINYL COMPOSITION TILE
VCT-3 STYLE: PROGRESSIONSCOLOR: BED ROCK 55519
MANNINGTONVINYL COMPOSITION TILE
BENJAMIN MOORE
COLOR: TRENCH COAT CSP-1020
ACCENT WALL PAINTPNT 5
B 4ALLSTATE4" CONT. RUBB. COVE BASE COLOR: A08
CONTACT:CHRISTINE LAKSO 404.803.8907
BENJAMIN MOORE
BENJAMIN MOORE
BENJAMIN MOORE
BENJAMIN MOORE
CONTROL JOINT
CONCRETE SAW CUT
VCT-1
VCT-2
VCT-3
NOT IN SCOPE
KITCHENG106
GYMNASIUMG107
CORRIDORG110
MEN'SG111
HOME TEAMLOCKERROOMG112 HOME TEAM
ROOMG113
JANG114
SUPPLYG115
CLOSETG116
VISITINGTEAM ROOM
G117
CORRIDORG118
WOMEN'SG119
VISITOR'SLOCKERROOMG120
CORRIDORG121
YOGA ROOMG124
CLASSROOMG125
CLASSROOMG126
UTILITYG127
WEIGHTTRAINING
G123
EXISTING RAMP AEROBICEXERCISE
G122
NO SCOPE OFWORK AT THIS AREA
NO SCOPE OF WORKIN THIS AREA
NO SCOPE OF WORKIN THIS AREA
G127
VCT-3
B 1PNT 1
RF-1
B 1PNT 1
RB-1
B 1PNT 1
RF-1
B 1PNT 1
PT-1
B 2PNT 1
VCT
B 1PNT 1
VCT-1
B 1PNT 1
PT-1
B 2PNT 1
PT-1
B 2PNT 1PT-1
B 2
PNT 1PT 1
6'-0
"6'
-0"
9'-0
"
1'-0
"
4'-0
"2'
-0"
3'-0
"4'
-0"
6'-0
"
2'-0
"
5'-0
"2'
-0"
5'-0
"6'
-0"
4'-0
"
2'-0
"
4'-0
"1'
-0"
12'-0
"
PNT 4 PNT 4
PNT 4
PNT 4
PNT 5
PNT 5
PNT 5
PNT 4
1'-0
"
4'-0
"
2'-0
"
3'-0
"
VCT-1
B 1PNT 1
VCT-3
B 1PNT 1
PROVIDE TRANSITIONTO ATHLETIC FLOORING
PROVIDE TRANSITIONTO ATHLETIC FLOORING
PROVIDE TRANSITIONTO ATHLETIC FLOORING
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:46 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
As indicated
A401
GYMNASIUMBUILDING
FINISH PLAN
BEM
MS
1/29/16
14640GILEADLEGEND
1/8" = 1'-0"A4011 GYMNASIUM FINISH FLOOR PLAN
WH
1. ALL FINISHES AND MATERIALS SHALL BE AS INDICATED IN THE FINISH LEGEND. NO SUBSTITUTIONS WILL BE ACCEPTEDWITHOUT PRIOR APPROVAL BY THE ARCHITECT.
2. UNLESS OTHERWISE NOTED, ALL EXISTING GYPSUM BOARD AND CMU WALLS IN AFFECTED AREAS ARE TO REPAINTED. ALLPAINT COLOR THROUGHOUT IS TO BE PNT-1.
3. UNLESS OTHERWISE NOTED, ALL EXISTING AND NEW GYP. BD. CEILINGS AND BULKHEADS IN AFFECTED AREAS ARE TO BEPAINTED PNT-2, FLAT FINISH.
4. ALL H.M. FRAMES AND TRIM IN AFFECTED AREAS ARE TO BE PAINTED PNT-3, GLOSS FINISH U.N.O.
6. WHERE SEAMS IN FLOORING MATERIALS OCCUR AT DOORS, THEY SHALL BE PARALLEL WITH THE DOOR IN THECLOSED POSITION AND CENTERED ON THE THICKNESS OF THE DOOR UNLESS INDICATED OTHERWISE BY NOTE ON THEFINISH PLAN.
7. RESILIENT FLOORING SHALL BE VINYL COMPOSITION TILE 12" x 12" x 1/8" THICK. WHERE FLOORING MATERIALS OFDIFFERING THICKNESS (TILE TO VCT) INTERSECT, PROVIDE TILE TRANSITION ACCESSORIES AS REQUIRED.
8. ALL FINISHES ARE TO BE SUBMITTED TO ARCHITECT PRIOR TO INSTALLATION FOR APPROVAL. SUBMITTAL TO BE ASSPECIFIED IN THE PROJECT MANUAL, AND ARE NOT TO BE SMALLER THAN 12" X 12". PROVIDE A MINIMUM OF TWOSAMPLES PER FINISH IN SUBMITTAL.
9. ALL SURFACES WHICH ARE TO RECEIVE A FINISH APPLICATION SHALL BE COMPLETELY SMOOTH.
10. ALL VCT SHALL BE ADHERED DIRECTLY TO THE SUB-FLOOR WITH ADHESIVE COMPATIBLE TO THE VCTMANUFACTURER'S RECOMMENDED SPECIFICATIONS.
11. AT TRANSITIONS FROM VCT TO RUBBER FLOORING; PROVIDE VINYL TRANSITION ACCESSORIES AS REQUIRED.
12. FURNISH AND INSTALL CONTINUOUS ROLL RUBBER BASE. WRAP BASE AT CASED OPENINGS AND STUB WALLS.
13. ALL WINDOW SILLS TO BE SS-1.
14. PROVIDE SCHLUTER COVE TRANSITION TRIM WHERE WALL TILE OR TILE BASE MEET FLOOR TILE; DILEX-HKU, STAINLESSSTEEL.
FINISH NOTES
SYMBOL DESCRIPTION/TYPE STYLE/COLOR REMARKS
RB-1 EXPANCORUBBER FLOOR
PT-1 CERAMIC TECHNICSPORCELAIN TILE 6X24
FLOOR
STYLE: REZTEC 8MMCOLOR: JET RED
PNT 1
PNT 2
PNT 3
WALLS
COLOR: GENTLE CREAM OC-96
B 1
B 2
ALLSTATE4" CONT. RUBB. COVE BASE
BASE
CERAMIC TECHNICS3 X 12 BULLNOSE BASE
COLOR: D49
STYLE: STUDIO MARMI LIMESTONECOLOR: MOCHA BROWN HONED
COLOR: CHANTILLY LACE OC-65
COLOR: SW7018 DOVETAIL
PNT 4 COLOR: SILKEN BLUE CSP-670
FINISH LEGEND
CHANGE IN FLOORMATERIAL
CONTROL JOINT
CONCRETE SAW CUT
STYLE: STUDIO MARMI WOOD GRAINCOLOR: GRIGIO
RF-1 STYLE: XCRCOLOR: GRAVEL
EXPANCORESILIENT FLOORING
VCT-1 STYLE: PROGRESSIONSCOLOR: WHEAT 551123
FEILD PAINT
GYPSUM CEILING PAINT
HOLLOW METAL AND TRIM PAINT
ACCENT WALL PAINT
MANNINGTONVINYL COMPOSITION TILE
PT-1 TRINITY TILEPORCELAIN TILE 12X12
STYLE: ARGONITECOLOR: EARTH MATTE
B 3CERAMIC TECHNICS3 X 12 BULLNOSE BASE
STYLE: CTL METROPOLISCOLOR: MOCHA
CONTACT: NICOLE HIGGINS 770.740.0050 X224
CONTACT: NICOLE HIGGINS 770.740.0050 X224
CONTACT: NICOLE HIGGINS 770.740.0050 X224
CONTACT: ELIZABETH CHAMBLEY 770.856.5139
CONTACT:CHRISTINE LAKSO 404.803.8907
VCT-2 STYLE: PROGRESSIONSCOLOR: BRONZE 55246
MANNINGTONVINYL COMPOSITION TILE
VCT-3 STYLE: PROGRESSIONSCOLOR: BED ROCK 55519
MANNINGTONVINYL COMPOSITION TILE
BENJAMIN MOORE
COLOR: TRENCH COAT CSP-1020
ACCENT WALL PAINTPNT 5
B 4ALLSTATE4" CONT. RUBB. COVE BASE COLOR: A08
CONTACT:CHRISTINE LAKSO 404.803.8907
BENJAMIN MOORE
BENJAMIN MOORE
BENJAMIN MOORE
BENJAMIN MOORE
CONTROL JOINT
CONCRETE SAW CUT
VCT-1
VCT-2
VCT-3
NOT IN SCOPE
CLASSROOMM101
ELECM102
UTILITYM103
JANM104
CORRIDORM105
WORKROOMM106
RESOURCEROOMM107
CLASSROOMM108
CORRIDORM109
CLASSROOMM110
CLASSROOMM111
BOYSM112
GIRLSM113
CLASSROOMM116
COVEREDDROP-OFF TO REMAIN-
REPAINT
H/CRESTROOM
M114
CLOSETM115
PNT 1B 1
PNT 1B 1
PNT 1B 1
PNT 1B 1
PNT 1B 1
PNT 1B 1
PNT 1B 1
PNT 1B 1
PNT 1B 1
VCT-3
PNT 1B 3
PT-2 PNT 1B 1
VCT-2
VCT-2VCT-1VCT-1
VCT-1
VCT-1
VCT-3
VCT-1
VCT-1
PNT 4PNT 4
PNT 5 PNT 5PNT 4
PNT 5 PNT 5
5'-0" 4'-0" 6'-0" 4'-0" 4'-0" 7'-0"1'-0"
5'-0" 2'-0" 4'-0" 3'-0" 2'-0"5'-0"1'-0"2'-0"
13'-0"1'-0"
15'-0" 1'-0" 5'-0"1'-0"
7'-0" 5'-0"
CLASSROOMS101
CLOSETS102
SCIENCELABS103
CLASSROOMS104
MENSS105
WOMENSS106ELECT
S107
VCT-1
B 1PNT 1
VCT-2
B 1PNT 1
VCT-1
B 1PNT 1
VCT-1B 1PNT 1
PNT 4
PNT 5
PNT 4
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:47 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
As indicated
A402
SCHOOLBUILDINGS
FINISHPLANS
Checker
MS
1/29/16
14640GILEAD
LEGEND
1/8" = 1'-0"A4021 MIDDLE SCHOOL FINISH FLOOR PLAN
1/8" = 1'-0"A4022 STEM BUILDING FINISH FLOOR PLAN
NO. DESCRIPTION REMARKS
JUMBO ROLL PAPER TOWELDISPENSER
TOILET PAPER DISPENSER
SURFACE-MOUNTED SOAPDISPENSER
GRAB BAR 36" BLOCKING AS REQUIRED; ALLH.C. TOILETS
GRAB BAR 42"
COAT HOOK
B
C
D
E
F
MANUFACTURER MODEL NO. FINISH
BOBRICK B-72860
SATIN STAINLESS STEEL
GOJO NXT 1000 DOVE GREY
BOBRICK B-6806-36 SATIN STAINLESS STEEL
BOBRICK B-6806-42 SATIN STAINLESS STEEL
MFR. STANDARD
BLOCKING AS REQUIRED; ALLH.C. TOILETS
G
H
ACCESSORIES LEGEND
BOBRICK B-212 SATIN STAINLESS STEEL
BOBRICK B-2892
MIRROR CHANNEL FRAMED
INSIDE FACE OF DOOR
MOUNT AT 42" AFF TO BOTTOMA
BOBRICK B-1652436 MOUNT AT 40" AFF TOBOTTOM
PLATE GLASS MIRROR 36" HIGH X FULL WIDTH OF VANITYPOLISHED EDGES
33" -
36"
T.O
. RIM
AD
A 17
"T.
O. R
IM 1
5"
1'-0" MIN. 3'-6"
4'-6" MIN.
1'-0" MAX 3'-0"
33" -
36"
17" M
AX
44" M
AX
48" M
AX
40" M
AX
27" M
IN.
34" M
AX 48" M
AX 4'-6
"
1'-6"
31" M
IN.
WATER CLOSETTOILET PAPER DISPENSER
GRAB BAR
ADA URINAL INSULATE HOT WATERAND WASTE LINES
MIRROR
SOAPDISPENSER
LAVATORY
PAPER TOWELDISPENSER
COAT HOOK
NOTE: REFER TORESTROOM ELEVATIONSFOR OTHER INFORMATION
2'-0
"
URINAL
A501 7
5
6
B.1
B.1
G112A
G112B
C
D
E
NEW 12"X18"X72" METAL LOCKERS
6'-0" 1'-4"
7'-4
"
NEW DOOR ANDFRAME IN NEWOPENING
F
CLOSE AND LOCKEXISTING DOOR
B
A
B.1
HOME TEAMLOCKERROOMG112
HOME TEAMLOCKERROOMG112
G120A
A5019
B
CLOSE AND LOCKEXISTING DOOR
NEW 12"X18"X72" METAL LOCKERS
7'-6
"
1'-4" 6'-0"
8
H
C
D
E B
A
VISITOR'SLOCKERROOMG120 B.1
B.1
A501 11
10
9'-5
"
D
EB
5'-0
"C
LEAR
FA
A501
A501
12
135'-1
" 5'-1
"
B.1
C
H
A
A
EXISTING FIXTURES ANDTOILET PARTITIONS TOREMAIN U.N.O.- TYP.
EXISTING FIXTURES ANDTOILET PARTITIONS TOREMAIN U.N.O.- TYP.
C
G
C
G
H/CRESTROOM
M114
CLOSETM115
GIRLSM113
BOYSM112
EXISTING WALLS TO REMAIN
NOT IN SCOPE OF WORK
NEW WALL CONSTRUCTION
B
D
EC
H
E
D
ABC
F
AH
CD
B
H
C
D
B
A
E B
DAEB
A
G
C
14A501
AC
G
14A501
6 13/16"
1'-11 1/4"
4"1
1/2" 3"
2'-5
1/2
"
2'-1"
2'-1
0"
BACKSPLASH WITHCONTINUOUS SEALANT
PLASTIC LAMINATE OVER3/4" SUBSTRATE ATSCHEDULED COUNTERTOP1x4 BLOCKING
ANGLE SUPPORT BELOWCOUNTERTOP
1x4 BLOCKINGUNDERMOUNT ADA SINK
INSULATED DRAIN PIPE
3/4" PLYWOOD WITHSCHEDULED LAMINATEFINISH ON ALL EXPOSEDSURFACES
SCHEDULED FLOOR FINISH
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:49 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
As indicated
A501
ENLARGEDPLANS ANDINTERIOR
ELEVATIONS
BEM
MS
1/29/16
14640GILEAD
1/2" = 1'-0"A5014 TYP. MOUNTING HEIGHTS
ACCESSORIES ABOVE ARE THE BASIS OF DESIGN - ADDITIONAL PRODUCTS LISTED IN SPECIFICATIONS
1. PROVIDE WATERPROOF MEMBRANE BEHIND FLOOR AND WALLTILE AT RESTROOM LOCATIONS
2. SEAL ALL PENETRATIONS AT WALL PENETRATIONS IN LINE WITHWATERPROOFING MEMBRANE.
3. FLOOR DRAIN LOCATIONS SHOULD BE SET AT LOWEST POINTELEVATION IN ROOM
ENLARGED FLOOR PLAN NOTES
1/4" = 1'-0"A5011 HOME TEAM LOCKER RM
1/4" = 1'-0"A5012 VISITOR'S LOCKER RM
1/4" = 1'-0"A5013 MIDDLE SCHOOL RESTROOMS
ENLARGED FLOOR PLAN LEGEND
1/4" = 1'-0"A5019 INT ELEV AT G120
1/4" = 1'-0"A5015 INT ELEV AT G112
1/4" = 1'-0"A5016 INT ELEV AT G112
1/4" = 1'-0"A5017 INT ELEV AT G112
1/4" = 1'-0"A50111 INT ELEV AT M114
1/4" = 1'-0"A50110 INT ELEV AT M114
1/4" = 1'-0"A5018 INT ELEV AT G120
1/4" = 1'-0"A50112 INT ELEV AT M113
1/4" = 1'-0"A50113 INT ELEV AT M112
1 1/2" = 1'-0"A50114 MILLWORK SECTION
EXISTING BRICK VENEEROVER CONC. BLOCK-VERIFY THICKNESS ANDCAVITY DEPTH
EXISTING LINTEL-PRIME AND PAINT
SEALANT WITHBACKER ROD
INSUL. GLASS INALUM. FRAMING SYSTEM
SILL FLASHING WITHSEALANT AND BACKERROD- SEE DETAIL
ELASTOMERIC COATING ONSTUCCO OVER SHEATHINGON P.T.2X WOOD FURRING1-1/2" RIGID INSUL
CONC. SILL BLOCK-MATCH THICKNESS OFEXISTING BLOCK
CONT. CAULK JOINTAT PERIMETER
4"
1"
1"
2 5/8"
ELASTOMERIC COATING ONSTUCCO OVER SHEATHINGON P.T. 2X WOOD FURRING
1-1/2" RIGID INSUL
EXISTING BRICKSILL TO REMAIN
SEALANT WITHBACKER ROD
CONC. SILL BLOCK-MATCH THICKNESS OFEXISTING BLOCK
NEW FLORRING OVEREXISTING CONC. SLAB
EXISTING BRICK VENEEROVER CONCRETE BLOCK
AND FOUNDATION
ELASTOMERIC COATING ONCEMENTITIOUS STUCCO OVER
SHEATHING ON 2X WOOD FURRING
INSUL. GLASS IN ALUM.FRAMING SYSTEM AT
NEW WINDOW
EXISTING 2X WOOD FASCIA-PRIME AND PAINT
EXISTING BRICK VENEEROVER CONC. BLOCK
EXISTING ROOFING AND RIGID INSUL.OVER TECTUM DECKING ON STEEL
FRAMING TO REMAIN
NEW ACOUSTICAL TILECEILING SYSTEM IN
SUSPENDED GRID
NEW FLOORING OVEREXISTING FLOOR SLAB
A6014
A6015
ELASTOMERIC COATING ONSTUCCO OVER SHEATHINGON P.T. 2X WOOD FURRING
1-1/2" RIGID INSUL
EXISTING BRICK SILL TO REMAIN
SEALANT WITH BACKER ROD
INSUL. GLASS IN ALUM.FRAMING SYSTEM
CAULK JOINT
CONC. BLOCK AT SILL BELOW
ELASTOMERIC COATING ONSTUCCO OVER SHEATHINGON P.T. 2X WOOD FURRING
1-1/2" RIGID INSUL
EXISTING BRICK SILL TO REMAIN
SEALANT WITH BACKER ROD
CONC. BLOCK INFILL-MATCH THICKNESS OFEXISTING BLOCK
8'-0
"6"
1"EXISTING METAL CANOPY-PRIME AND PAINT
CAST STONE CAP-SLOPE TO EXISTING COLUMN-PROVIDE SEALANT WITH BACKERROD AT COLUMN PENETRATION
EXISTING STEEL FRAMING-PRIME AND PAINT EXPOSEDPORTION OF COLUMNS
BRICK VENEER OVERGYP. SHEATHING ONMETAL STUD FRAMINGWITH VENEER REINF.
PATCH AND REPAIREXISTING ASPHALT PAVING
THRU-WALL FLASHING WITHCELL TYPE WEEPS
NEW REINF. CONC.FOOTINGS- DOWEL INTOEXISTING FOOTING AT PIER
EXISTING METAL SOFFITAT CANOPY- PRIME AND PAINT
EXISTING ROOFING, DECKINGAND STRUCTURE ATCANOPY TO REMAIN
TOP OF STRUCTURAL SLAB
CONC. BLOCK-SEE SCHEDULE FORTHICKNESS AND FIRERATING
REINF. CONC. BLOCK BONDBEAM- FILL WITH GROUT
EXISTING DECK ABOVE
FILL CELLS WITH GROUT-DOWEL INTO FLOOR SLAB
TOP OF STRUCTURAL SLAB
CONC. BLOCK-SEE SCHEDULE FORTHICKNESS AND FIRERATING
REINF. CONC. BLOCK BONDBEAM- FILL WITH GROUT
DOWEL INTO FLOOR SLAB
CEILING SYSTEM
TOP OF STRUCTURAL SLAB
5/8" GYP. BOARD OVER2X4 EXISTING WOODFRAMING- MODIFY EXISTINGFRAMING AS REQUIRED
CEILING SYSTEM
EXISTING DECK ABOVE
BASE
PLAN
HEAD
BASE
PLAN
HEAD
BASE
PLAN
HEAD
A.1 8" CONCRETE BLOCK WALL (ONE HOUR RATED)EXTEND TO DECK ABOVEUL DESIGN NO. 905OVERALL DIMENSION 7-5/8"
B.1 4" CONCRETE BLOCK PARTITION (NON-RATED)EXTEND TO 6" ABOVE CEILINGOVERALL DIMENSION 3-5/8"
C.1 PARTITION (NON-RATED)5/8" GYP. BOARD ON BOTH SIDES OFEXISTING 2X4 WOOD FRAMING(MODIFY AS REQUIRED)EXTEND TO 6" ABOVE CEILINGOVERALL DIMENSION 4-3/4"
EXISTING 2X WOOD FASCIA-PRIME AND PAINT
EXISTING BRICK VENEEROVER CONC. BLOCK ATJAMB BEYOND
EXISTING ROOFING AND RIGID INSUL.OVER TECTUM DECKING ON STEELFRAMING TO REMAIN
NEW ACOUSTICAL TILECEILING SYSTEM INSUSPENDED GRID
NEW FLOORING OVEREXISTING FLOOR SLAB
INSTALL NEW DBL. H.M. DOORSIN EXISTING H.M FRAME-PRIME AND PAINT
NEW METAL THRESHOLD-SET IN MASTIC
4' X 8' PREFABRICATEDMETAL CANOPY WITHINTEGRAL GUTTER ANDTIE RODS
EXISTING SIDEWALKTO REMAIN
A3023
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:53 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
As indicated
A601
WALLSECTIONS,
DETAILSAND
PARTITIONTYPES
BEM
MS
1/29/16
14640GILEAD
1 1/2" = 1'-0"A6014 DETAIL AT WINDOW
1 1/2" = 1'-0"A6015 DETAIL AT INFILL SILL
3/4" = 1'-0"A6012 WALL SECTION AT WINDOW INFILL
1 1/2" = 1'-0"A6016 PLAN DETAIL AT WINDOW
1 1/2" = 1'-0"A6017 PLAN DETAIL AT STUCCO INFILL
3/4" = 1'-0"A6011 DETAIL AT COLUMN COVER
3/4" = 1'-0"A6013 WALL SECTION AT CANOPY
A SOLID CORE WOOD DOOR (STAIN)B HOLLOW METAL DOOR (PAINT)
SCH
EDU
LED
SCHEDULED
A SOLID CORE WOOD DOOR (STAIN)
SCHEDULED
6" 6"
?1 ?2
A SOLID CORE WOOD DOOR (STAIN)B HOLLOW METAL DOOR (PAINT)
EQ. EQ.
?4
SCHEDULED
SCH
EDU
LED
6"3'
-0"
SCH
EDU
LED
SCH
EDU
LED
EQ. EQ.
?5
A PREFINISHED ALUMINUMENTRANCE DOORS
SCHEDULED
?A
6" 6"
SCHEDULED
?3
6"10
"5'
-8"
SCH
EDU
LED
?E
A PREFINISHED ALUMINUMB HOLLOW METAL (PAINT)
6" 6" 6" 6"6"10
"5'
-8"
?E?E
2" SCHEDULED 2"
2"SC
HED
ULE
D
2" SCHEDULED 2"
2"SC
HED
ULE
D
A HOLLOW METAL (PAINT)B ALUMINUM (PREFINISHED)
?1 ?2
A HOLLOW METAL (PAINT)B ALUMINUM (PREFINISHED)
FINISH FLOOR
2'-0
"6'
-0"
A HOLLOW METAL (PAINT)B ALUMINUM (PREFINISHED)
2'-0"
?1
FINISH FLOOR
2'-8
"5'
-4"
A HOLLOW METAL (PAINT)B ALUMINUM (PREFINISHED)
2'-8"
?2
FINISH FLOOR
3'-0
"5'
-0"
A HOLLOW METAL (PAINT)B ALUMINUM (PREFINISHED)
3'-0"
?2
?D
?D?E
FINISHFLOOR
A HOLLOW METAL (PAINT)B ALUMINUM (PREFINISHED)
1'-2"
?4
?C
6'-1
0"
EXISTINGALUMINUMFRAME
H.M. DOOR INH.M. FRAME
METAL THRESHOLDSET IN SEALANT
1/2" EXPANSIONMATERIAL
CONCRETESIDEWALK
CONC. SLAB OVERVAPOR RETARDERON 4" GRAVEL BASE
1/4"
VARIES
1" M
IN
2"
9/16"VARIES
9/16"
SCHEDULED PARTITION
HOLLOW METAL DOOR FRAME
SCHEDULED DOOR
5/8"
METAL STUD HEADER
CONT. CAULK AROUNDPERIMETER; BOTH SIDES
NOTE:REFER TO DRAWINGS ANDSPECIFICATIONS FOR DOORAND FRAME HARDWARE
VAR
IES
1" MIN
MIN.4" 2"
9/16
"VA
RIE
S9/
16"
SCHEDULED PARTITION
HOLLOW METAL DOOR FRAME
SCHEDULED DOOR
5/8"
DOUBLE STUD AT JAMB
CONT. CAULK AROUNDPERIMETER; BOTH SIDES JAMB ANCHOR;
MIN. 3 PER JAMB
NOTE:REFER TO DRAWINGS ANDSPECIFICATIONS FOR DOORAND FRAME HARDWARE
INTERSECTING WALLLINE WHERE OCCURS
5 3/4"
2"
HOLLOW METAL DOOR FRAME
SCHEDULED DOOR
5/8"
CONC. LINTEL BLOCK
CONT. CAULK AROUNDPERIMETER; BOTH SIDES
NOTE:REFER TO DRAWINGS ANDSPECIFICATIONS FOR DOORAND FRAME HARDWARE
5 3/
4"
MIN.4" 2"
HOLLOW METALDOOR FRAME
SCHEDULED DOOR
5/8"
CONC. BLOCKPARTITION
CONT. CAULK AROUNDPERIMETER; BOTH SIDES
JAMB ANCHOR;MIN. 3 PER JAMB
NOTE:REFER TO DRAWINGS ANDSPECIFICATIONS FOR DOORAND FRAME HARDWARE
INTERSECTING WALLLINE WHERE OCCURS
SCHEDULED DOORAND FRAME
TRANSITION STRIP ASREQUIRED- CENTERUNDER DOOR
CONC. FLOOR SLAB
SCHEDULED FLOORFINISH
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
THIS DRAWING IS AN INSTRUMENT OFSERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NOPART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANYFORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,WITHOUT THE EXPRESS WRITTENPERMISSION OF THE ARCHITECT.
1700
CO
MM
ERC
E D
RIV
E, N
WAT
LAN
TA, G
EOR
GIA
303
18T:
404
605
069
0F:
404
605
089
0w
ww
.siz
emor
egro
up.c
om©
201
1 SI
ZEM
OR
E G
RO
UP
GIL
EAD
-BLO
OM
FIEL
D C
OM
PLEX
REN
OVA
TIO
N19
31 R
OC
KY C
REE
K R
OAD
MAC
ON
, GEO
RG
IA 3
1206
MAC
ON-
BIBB
CO
.C
ON
STR
UC
TIO
N D
OC
UM
ENTS
No.
DES
CR
IPTI
ON
DAT
E
2/12/2016 4:39:54 PMC:\Users\brucem\Documents\Gilead Gym-School CD Central File_brucem.rvt
As indicated
A701
DOORSCHEDULE
ANDDETAILS
BEM
MS
1/29/16
14640GILEAD
DOOR FRAMEFIRE
RATING
HARDWARE
DOOR COMMENTSDOOR # LOCATION TYPE WIDTH HEIGHTTHICKNE
SS MATERIAL FINISH TYPEMATERI
AL FINISH HEAD JAMB SILL SET TYPE PANIC
G112A GYMNASIUM LOCKER ROOM 1A 3'-0" 6'-8" 1-3/4" WOOD STAIN 1A METAL PAINT 3/A701 4/A701 6/A701 1G112B GYMNASIUM LOCKER ROOM 1A 3'-0" 6'-8" 1-3/4" WOOD STAIN 1A METAL PAINT 3/A701 4/A701 6/A701 2G120A GYMNASIUM LOCKER ROOM 1A 3'-0" 6'-8" 1-3/4" WOOD STAIN 1A METAL PAINT 3/A701 4/A701 6/A701 1G120B GYMNASIUM LOCKER ROOM 1A 3'-0" 6'-8" 1-3/4" WOOD STAIN 1A METAL PAINT 3/A701 4/A701 6/A701 2G121A GYMNASIUM CORRIDOR 4B 6'-0" 6'-8" 1-3/4" METAL PAINT 2A METAL PAINT 3/A701 4/A701 5/A701 3 YG121B GYMNASIUM CORRIDOR 5A 6'-0" 6'-8" 1-3/4" STOREFRONT ALUM EXISTING ALUM ALUM 3/A701 4/A701 5/A701 4 Y NEW DOORS IN EXISTING FRAMEG122A GYMNASIUM AEROBIC
EXCERCISE2A 3'-0" 6'-8" 1-3/4" WOOD STAIN 1A METAL PAINT 3/A701 4/A701 6/A701 20 MIN 5 Y
G122B GYMNASIUM AEROBICEXCERCISE
2A 3'-0" 6'-8" 1-3/4" WOOD STAIN 1A METAL PAINT 3/A701 4/A701 6/A701 20 MIN 5 Y
G122C GYMNASIUM AEROBICEXCERCISE
1B 3'-0" 6'-8" 1-3/4" METAL PAINT EXISTING METAL PAINT 3/A701 4/A701 5/A701 6 Y NEW DOOR IN EXISTING FRAME
G123A GYMNASIUM WEIGHT TRAINING 2A 3'-0" 6'-8" 1-3/4" WOOD STAIN 1A METAL PAINT 3/A701 4/A701 6/A701 20 MIN 5 YG123B GYMNASIUM WEIGHT TRAINING 1B 3'-0" 6'-8" 1-3/4" METAL PAINT EXISTING METAL PAINT 3/A701 4/A701 5/A701 6 Y NEW DOOR IN EXISTING FRAMEG124A GYMNASIUM YOGA 2A 3'-0" 6'-8" 1-3/4" WOOD STAIN EXISTING METAL PAINT 3/A701 4/A701 6/A701 20 MIN 7 NEW DOOR IN EXISTING FRAMEG124B GYMNASIUM YOGA 1B 3'-0" 6'-8" 1-3/4" METAL PAINT EXISTING METAL PAINT 3/A701 4/A701 5/A701 8G125A GYMNASIUM CLASSROOM 2A 3'-0" 6'-8" 1-3/4" WOOD STAIN EXISTING METAL PAINT 3/A701 4/A701 6/A701 20 MIN 7 NEW DOOR IN EXISTING FRAMEG125B GYMNASIUM CLASSROOM 1B 3'-0" 6'-8" 1-3/4" METAL PAINT EXISTING METAL PAINT 3/A701 4/A701 5/A701 8 NEW DOOR IN EXISTING FRAMEG126A GYMNASIUM CLASSROOM 2A 3'-0" 6'-8" 1-3/4" WOOD STAIN EXISTING METAL PAINT 3/A701 4/A701 6/A701 20 MIN 7 NEW DOOR IN EXISTING FRAMEG126B GYMNASIUM CLASSROOM 1B 3'-0" 6'-8" 1-3/4" METAL PAINT EXISTING METAL PAINT 3/A701 4/A701 5/A701 8 NEW DOOR IN EXISTING FRAMEM101 MIDDLE SCHOOL CLASSROOM 2A 3'-0" 6'-8" 1-3/4" WOOD STAIN EXISTING METAL PAINT 3/A701 4/A701 6/A701 20 MIN 7 NEW DOOR IN EXISTING FRAMEM103 MIDDLE SCHOOL UTILITY 1A 3'-0" 6'-8" 1-3/4" WOOD STAIN EXISTING METAL PAINT 3/A701 4/A701 6/A701 20 MIN 9 NEW DOOR IN EXISTING FRAMEM104 MIDDLE SCHOOL JANITOR CL. 1A 2'-8" 6'-8" 1-3/4" WOOD STAIN EXISTING METAL PAINT 3/A701 4/A701 6/A701 20 MIN 10 NEW DOOR IN EXISTING FRAMEM105 MIDDLE SCHOOL CORRIDOR 1B 3'-0" 6'-8" 1-3/4" METAL PAINT 1A METAL PAINT 3/A701 4/A701 5/A701 11 YM106 MIDDLE SCHOOL WORKROOM 1A 3'-0" 6'-8" 1-3/4" WOOD STAIN 1A METAL PAINT 3/A701 4/A701 6/A701 20 MIN 7M107A MIDDLE SCHOOL RESOURCE
ROOM2A 3'-0" 6'-8" 1-3/4" WOOD STAIN EXISTING METAL PAINT 3/A701 4/A701 6/A701 20 MIN 7 NEW DOOR IN EXISTING FRAME
M107B MIDDLE SCHOOL RESOURCEROOM
3'-0" 6'-8" 1-3/4" 1A METAL PAINT 1/A701 2/A701 6/A701 12 NEW CASED OPENING
M108 MIDDLE SCHOOL CLASSROOM 2A 3'-0" 6'-8" 1-3/4" WOOD STAIN EXISTING METAL PAINT 3/A701 4/A701 6/A701 20 MIN 7 NEW DOOR IN EXISTING FRAMEM109A MIDDLE SCHOOL MAIN ENTRY 3A 3'-0" 6'-8" 1-3/4" STOREFRONT ALUM EXISTING ALUM ALUM --- --- --- 13 Y NEW DOOR IN EXISTING FRAMEM109B MIDDLE SCHOOL CORRIDOR 4B 3'-0" 6'-8" 1-3/4" METAL PAINT EXISTING METAL PAINT 3/A701 4/A701 5/A701 3 Y NEW DOORS IN EXISTING FRAMEM109C MIDDLE SCHOOL CORRIDOR 4B 3'-0" 6'-8" 1-3/4" METAL PAINT EXISTING METAL PAINT 3/A701 4/A701 5/A701 3 Y NEW DOORS IN EXISTING FRAMEM110 MIDDLE SCHOOL CLASSROOM 2A 3'-0" 6'-8" 1-3/4" WOOD STAIN EXISTING METAL PAINT 3/A701 4/A701 6/A701 20 MIN 7 NEW DOOR IN EXISTING FRAMEM111 MIDDLE SCHOOL CLASSROOM 2A 3'-0" 6'-8" 1-3/4" WOOD STAIN EXISTING METAL PAINT 3/A701 4/A701 6/A701 20 MIN 7 NEW DOOR IN EXISTING FRAMEM112 MIDDLE SCHOOL BOYS
RESTROOM1A 3'-0" 6'-8" 1-3/4" WOOD STAIN EXISTING METAL PAINT 3/A701 4/A701 6/A701 20 MIN 1 NEW DOOR IN EXISTING FRAME
M113 MIDDLE SCHOOL GIRLSRESTROOM
1A 3'-0" 6'-8" 1-3/4" WOOD STAIN EXISTING METAL PAINT 3/A701 4/A701 6/A701 20 MIN 1 NEW DOOR IN EXISTING FRAME
M114 MIDDLE SCHOOL H/CRESTROOM
1A 3'-0" 6'-8" 1-3/4" WOOD STAIN 1A METAL PAINT 3/A701 4/A701 6/A701 20 MIN 14
M115 MIDDLE SCHOOL CLOSET 1A 3'-0" 6'-8" 1-3/4" WOOD STAIN 1A METAL PAINT 3/A701 4/A701 6/A701 15M116 MIDDLE SCHOOL CLASSROOM 2A 3'-0" 6'-8" 1-3/4" WOOD STAIN EXISTING METAL PAINT 3/A701 4/A701 6/A701 20 MIN 7 NEW DOOR IN EXISTING FRAMES101 STEM CLASSROOM 1B 3'-0" 6'-8" 1-3/4" METAL PAINT 1A METAL PAINT 3/A701 4/A701 5/A701 16 NEW DOOR AND FRAME IN EXISTING
OPGS103A STEM SCIENCE LAB 1B 3'-0" 6'-8" 1-3/4" METAL PAINT 1A METAL PAINT 3/A701 4/A701 5/A701 16 NEW DOOR AND FRAME IN EXISTING
OPGS104 STEM CLASSROOM 1B 3'-0" 6'-8" 1-3/4" METAL PAINT 1A METAL PAINT 3/A701 4/A701 5/A701 16 NEW DOOR AND FRAME IN EXISTING
OPG
1/4" CLEAR TEMPERED
GLAZING SCHEDULE
?A
1/4" CLEAR FLOAT?B
1" INSULATED (LOW E) / TEMPERED, TINTED?C
1" INSULATED (LOW E), TINTED?D
1" INSULATED (LOW E ) , TINTED WITHINTERIOR OPAQUE FILM
?E
DOOR TYPES
DOOR FRAME TYPES
WINDOW TYPES
3" = 1'-0"A7015 EXTERIOR DOOR THRESHOLD
3" = 1'-0"A7011 HM DOOR HEAD
3" = 1'-0"A7012 HM DOOR JAMB
3" = 1'-0"A7013 CMU DOOR HEAD
3" = 1'-0"A7014 CMU DOOR JAMB
3" = 1'-0"A7016 INTERIOR DOOR THRESHOLD
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JCW
TWT
14640GILEAD
1-29-16
TO REMAIN
EXISTING KITCHEN
TO REMAIN
EXISTING GYMNASIUM
CONSTRUCTION
PHASE II
ROOM
MEETING
G1
ROOM
MULTI-PURPOSE
G2
KITCHEN
G4
GYMNASIUM
G5
SUPPLY
G6
SUPPLY
G7
MENS
G8
ROOM
LOCKER
G109
CORRIDOR
G10
JAN
G12
ROOM
HOME TEAM
G11
ROOM
SUPPLY
G13
CLOSET
G14
TEAM ROOM
VISITOR’S
G16
CORRIDOR
G15
WOMEN’S
G17
ROOM
LOCKER
G18
CORRIDOR
G19
CLASSROOM
G22
CLASSROOM
G23
CLASSROOM
G24
CLASSROOM
G25
CLASSROOM
G26
UTILITY
G27
PANTRY
G3
CLASSROOM
G21
CLASSROOM
G20
1SCALE:
1= 1’-0
88 0 4 8 16
NED101
LINE LEGEND
EXISTING TO REMAIN
DEMOLITION
GENERAL NOTES:(THIS SHEET ONLY)
COORDINATE DEMOLITION WORK WITH NEW WORK.
CONDITIONS AT THE SITE MAY VARY.
NEITHER THE OWNER NOR THE ARCHITECT WARRANT THESE TO BE "AS-BUILT" DOCUMENTS AND ACTUAL
DRAWINGS FOR ARCHITECTURAL AND ENGINEERING WORK HAVE BEEN PREPARED USING "AS-DESIGN" DOCUMENTS.
DEMOLITION/NEW WORK.
WAY RELIEVES THE CONTRACTOR FROM PROVIDING ANY AND ALL WORK REQUIRED TO COMPLETE THE
THE WORK INDICATED IS INTENDED TO SHOW THE GENERAL SCOPE OF DEMOLITION/NEW WORK AND IN NO
OR NEAR AREA REQUIRING WORK.
PROTECT FROM DAMAGE/MAINTAIN EXISTING ITEMS, COMPONENTS, BUILDING SYSTEMS, ETC. ADJACENT TO
CONTRACTOR TO LIMIT THE AMOUNT OF NOISE, DUST, AND POLLUTION.
DETRIMENTAL TO THE INSTALLATION OF NEW WORK.
NEW WORK: REMOVE PAINT, DUST, MASTIC, MORTAR, SEALANT, FASTENERS, BRACKETS, ETC. WHICH WILL BE
AFTER DEMOLITION SHALL BE MADE CLEAN, FREE OF DEBRIS, AND SUITABLE FOR THE INSTALLATION OF
WHERE EXISTING MATERIALS ARE INDICATED TO BE REMOVED, SURFACES AND EDGES OF MATERIALS REMAINING
FINISHES, COLOR, TEXTURE, QUALITY, ETC.)
SUCH SURFACES SHALL BE REPAIRED TO MATCH EXISTING (IN MATERIAL, SIZE, ALIGNMENT, JOINT WORK,
WHERE SURFACES ARE DAMAGED BY DEMOLITION (INCLUDING MECHANICAL, ELECTRICAL, AND PLUMBING WORK),
A
B
C
D
E
F
G
H
SURROUNDINGS.
BOXES. WHERE CONDUIT IN SLAB IS ABANDONED CUT FLUSH TO FLOOR AND FINISH TO MATCH EXISTING
TERMINATION. THERE SHALL BE NO UNTERMINATED CONDUCTORS. PROVIDE BLANK COVER FOR ANY ABANDONED
REMOVE ALL CONDUCTORS FROM CIRCUITS THAT WILL NO LONGER BE IN USE TO THE POINT OF LAST
DISCONNECT AND REMOVE ABANDONED PANELBOARDS AND DISTRIBUTION EQUIPMENT.I
NOTES:(THIS SHEET ONLY)
1
2
3
4
CONDUCTORS BACK TO SERVING BREAKER.
HVAC UNIT TO BE REMOVED. REMOVE ASSOCIATED DISCONNECT AND SUPPORTING CONDUIT/
OF THE CONDUIT RACEWAY MAY BE REUSED SEE E201 FOR NEW WORK.
AND CONDUCTORS & SUPPORTS SERVING THIS SPACE. EXISTING SWITCH BOXES AND PORTIONS
REMOVE ALL OF THE LIGHTING FIXTURES, SWITCHES AND THE ASSOCIATED CONDUIT RACEWAY
1
1
2
23
3
3
3
3
3
4
FACP
5
EXISTING FIRE ALARM SYSTEM PANEL TO BE REUSED FOR NEW WORK.
FROM THIS SPACE. SEE E401 FOR NEW WORK.
REMOVE EXISTING FIRE ALARM NOTIFICATION AND ACTIVATION CIRCUITS, DEVICES, AND RACEWAY
5
5
1 2 5
1 2 5
1 2 5
1 2 5
1 2 5
1 2 5
1 2 5
1 2 5
1 2 5
1 2 5
1 2 5
1 2 5
PROVIDED TO REPLACE BROKEN/DAMAGED RECEPTACLES WITH NEW. SEE E301 FOR NEW WORK.
THIS SPACE SHALL BE MAINTAINED IN WORKING CONDITION. AN ALLOWANCE WILL BE
EXISTING RECEPTACLES AND ASSOCIATED CONDUIT RACEWAY AND CONDUCTORS SERVING
GYMNASIUM - DEMOLITION - ELECTRICAL
ELECTRICAL;
DEMOLITION -
GYMNASIUM -
ITERATIVE PROCESS DURING CONSTRUCTION.
CIRCUITS AS SPARE CIRCUITS, ANY ADDED CIRCUITS, AND EXISTING TO REMAIN CIRCUITS. THIS WILL BE A
REMAIN DEVICES. PROVIDE A PANEL CIRCUIT DIRECTORY THAT WILL BE UPDATED TO SHOW ANY DEMOLISHED
CONTRACTOR SHALL SCHEDULE TIME TO TRACE CIRCUITS FROM THE SERVING PANEL TO ANY EXISTING TO J
6
6
6
REMOVE EXIT SIGN. SEE E201 FOR NEW WORK.
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JCW
TWT
14640GILEAD
1-29-16
CLASSROOM
8
CLASSROOM
9
ELECT
10
UTILITY
11
JAN
12
OFFICE
13
OFFICE
14
WORKROOM
15
CLASSROOM
16
CLASSROOM
17
CORRIDOR
18
CLASSROOM
19
CLASSROOM
20
CLASSROOM
21
BOYS
22
GIRLS
23
GIRLS
24
BOYS
25
CLASSROOM
26
WH
CLASSROOM
1
CLOSET
2
LAB
SCIENCE
3
CLASSROOM
4
ELECT
5
WOMENS
6
MENS
7
2SCALE:
1= 1’-0
88 0 4 8 16
N1
SCALE:1
= 1’-08
8 0 4 8 16
N
ED102
LINE LEGEND
EXISTING TO REMAIN
DEMOLITION
STEM BUILDING - DEMOLITION - ELECTRICAL MIDDLE SCHOOL - DEMOLITION - ELECTRICAL
GENERAL NOTES:(THIS SHEET ONLY)
COORDINATE DEMOLITION WORK WITH NEW WORK.
CONDITIONS AT THE SITE MAY VARY.
NEITHER THE OWNER NOR THE ARCHITECT WARRANT THESE TO BE "AS-BUILT" DOCUMENTS AND ACTUAL
DRAWINGS FOR ARCHITECTURAL AND ENGINEERING WORK HAVE BEEN PREPARED USING "AS-DESIGN" DOCUMENTS.
DEMOLITION/NEW WORK.
WAY RELIEVES THE CONTRACTOR FROM PROVIDING ANY AND ALL WORK REQUIRED TO COMPLETE THE
THE WORK INDICATED IS INTENDED TO SHOW THE GENERAL SCOPE OF DEMOLITION/NEW WORK AND IN NO
OR NEAR AREA REQUIRING WORK.
PROTECT FROM DAMAGE/MAINTAIN EXISTING ITEMS, COMPONENTS, BUILDING SYSTEMS, ETC. ADJACENT TO
CONTRACTOR TO LIMIT THE AMOUNT OF NOISE, DUST, AND POLLUTION.
DETRIMENTAL TO THE INSTALLATION OF NEW WORK.
NEW WORK: REMOVE PAINT, DUST, MASTIC, MORTAR, SEALANT, FASTENERS, BRACKETS, ETC. WHICH WILL BE
AFTER DEMOLITION SHALL BE MADE CLEAN, FREE OF DEBRIS, AND SUITABLE FOR THE INSTALLATION OF
WHERE EXISTING MATERIALS ARE INDICATED TO BE REMOVED, SURFACES AND EDGES OF MATERIALS REMAINING
FINISHES, COLOR, TEXTURE, QUALITY, ETC.)
SUCH SURFACES SHALL BE REPAIRED TO MATCH EXISTING (IN MATERIAL, SIZE, ALIGNMENT, JOINT WORK,
WHERE SURFACES ARE DAMAGED BY DEMOLITION (INCLUDING MECHANICAL, ELECTRICAL, AND PLUMBING WORK),
A
B
C
D
E
F
G
H
SURROUNDINGS.
BOXES. WHERE CONDUIT IN SLAB IS ABANDONED CUT FLUSH TO FLOOR AND FINISH TO MATCH EXISTING
TERMINATION. THERE SHALL BE NO UNTERMINATED CONDUCTORS. PROVIDE BLANK COVER FOR ANY ABANDONED
REMOVE ALL CONDUCTORS FROM CIRCUITS THAT WILL NO LONGER BE IN USE TO THE POINT OF LAST
DISCONNECT AND REMOVE ABANDONED PANELBOARDS AND DISTRIBUTION EQUIPMENT.I
NOTES:(THIS SHEET ONLY)
1
2
3
4
CONDUCTORS BACK TO SERVING BREAKER.
HVAC UNIT TO BE REMOVED. REMOVE ASSOCIATED DISCONNECT AND SUPPORTING CONDUIT/
OF THE CONDUIT RACEWAY MAY BE REUSED SEE E202 FOR NEW WORK.
AND CONDUCTORS & SUPPORTS SERVING THIS SPACE. EXISTING SWITCH BOXES AND PORTIONS
REMOVE ALL OF THE LIGHTING FIXTURES, SWITCHES AND THE ASSOCIATED CONDUIT RACEWAY
5
FROM THIS SPACE. SEE E402 FOR NEW WORK.
REMOVE EXISTING FIRE ALARM NOTIFICATION AND ACTIVATION CIRCUITS, DEVICES, AND RACEWAY
PROVIDED TO REPLACE BROKEN/DAMAGED RECEPTACLES WITH NEW. SEE E302 FOR NEW WORK.
THIS SPACE SHALL BE MAINTAINED IN WORKING CONDITION. AN ALLOWANCE WILL BE
EXISTING RECEPTACLES AND ASSOCIATED CONDUIT RACEWAY AND CONDUCTORS SERVING
J
6
ON BREAKERS MATCHING THE TRIP RATING OF THE EXISTING BREAKERS.
THIS PANEL SHALL BE PULLED INTO THE NEW 200A PANEL INDICATED ON E302 AND TERMINATED
DISTRIBUTION PANEL. SEE E501 AND E701 FOR DETAILS. EXISTING RECEPTACLE CIRCUITS FED INTO
THE EXISTING ELECTRICAL PANEL WILL BE REPLACED IN THE SAME LOCATION WITH A NEW 6
6
WITHIN THE PANEL SCHEDULES ON SHEET E701.
BREAKERS FOR ALL EXISTING TO REMAIN CIRCUITS AS WELL AS THE NEW CIRCUITS AND BREAKERS INDICATED
REQUIRED BREAKER CONFIGURATION OF THE NEW ELECTRICAL PANELS. THE NEW PANELS SHALL INCLUDE
ITERATIVE PROCESS DURING CONSTRUCTION. THIS SCHEDULE WILL BE UTILIZED TO DETERMINE THE
CIRCUITS AS SPARE CIRCUITS, ANY ADDED CIRCUITS, AND EXISTING TO REMAIN CIRCUITS. THIS WILL BE A
REMAIN DEVICES. PROVIDE A PANEL CIRCUIT DIRECTORY THAT WILL BE UPDATED TO SHOW ANY DEMOLISHED
CONTRACTOR SHALL SCHEDULE TIME TO TRACE CIRCUITS FROM THE SERVING PANEL TO ANY EXISTING TO
1 2 5
1 2 5
1 2 5 1 2 5
1 2 5
1 2 5
1 2 5
1 2 5
1 2 5 1 2 5
1 2 5
1 2 51 2 5 1 2 5
1 2 5
1
2
5
1
2
5
EXISTING FIRE ALARM SYSTEM PANEL TO BE DEMOLISHED IN ITS ENTIRETY.
4
FA
CP
4
FACP
ELECTRICAL
DEMOLITION -
BUILDINGS -
SCHOOL
7
7
7 1 2 5 7 1 2 5 7
1 2 5 7
1 2 5 7
1 2 5 7
ENTIRETY.
CONDUIT RACEWAY & CONDUCTORS, AND THE EXISTING INTERCOM SYSTEM IN IT’S
REMOVE ALL OF THE EXISTING CEILING MOUNTED SPEAKERS, THE ASSOCIATED
7 7
7
7
77
7 1 2 5 7
1 2 5 7
7 7
777
1 2 5 71 2
5 7
7
7
7
8 REMOVE EXISTING BELL AND HORNS AND THE INTERSECTION OF THE TWO CORRIDORS.
8
9
9 REMOVE EXIT SIGN. SEE E202 FOR NEW WORK.
93
3
3
3
3 3 3 3 33
3 3 3 3 3
3 3 3 3 3 3 3 3
3
3
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JCW
TWT
14640GILEAD
1-29-16
E001
U
SP
DP
PE
EWC
WP
H
CT
F
T
M
JJ J
TV
GG
G
G
##/##/#
#
#
#/#
B
I
UI
I
K
L
D
I
P
3
2
4
FLUORESCENT ON "NORMAL" POWER
CEILING MOUNTED FIXTURE
WALL MOUNTED FIXTURE
(WITH INTEGRAL BATTERY PACK)
EXIT LIGHT (ARROWS AS SHOWN)
(UNSWITCHED NIGHT LIGHT FIXTURE)
(LIFE SAFETY EGRESS FIXTURE)
LIGHTING FIXTURES
ELECTRICAL LEGEND
LIGHTING CONTROL
RELAY PANEL
CEILING MOUNTED ULTRASONIC OCCUPANCY
SENSOR AND RELAY
CEILING/WALL MOUNTED INFRARED OCCUPANCY
SENSOR AND RELAY
CEILING MOUNTED COMBINATION INFRARED/
ULTRASONIC OCCUPANCY SENSOR AND RELAY
SWITCHING PHOTOCELL (INTERIOR TYPE) F.C. NOTED
DIMMING PHOTOCELL (INTERIOR TYPE)
EXTERIOR TYPE PHOTO ELECTRIC SWITCHLOW VOLTAGE SWITCH
INFRARED OCCUPANCY SENSOR
WALL MOUNTED SWITCH
"P" INDICATES PILOT LIGHT
KEYED SWITCH
DIMMER SWITCH
FOUR WAY SWITCH
THREE WAY SWITCH
TWO POLE SWITCH
SINGLE POLE SWITCH
RECEPTACLES
DUPLEX - NORMAL
QUADRAPLEX - NORMAL
GFI DUPLEX - NORMAL
GFI QUADRAPLEX - NORMAL
CEILING OUTLET DUPLEX - NORMAL CEILING SPECIAL - TYPE NOTED OR SHOWN
SPECIAL - TYPE NOTED OR SHOWN
HORIZONTALLY MOUNTED
WEATHER PROOF OUTLET
ELECTRIC WATER COOLER OUTLET
CIRCUITS
ONE CROSSMARK PER WIRE
(3 WIRE UNLESS SHOWN)
RACEWAY CONCEALED IN CEILING OR WALL
RACEWAY IN GROUND, SLAB, OR UNDER FLOOR
HOMERUN- ONE ARROW PER CIRCUIT
CONNECTION TO EQUIPMENT
CAP
CONDUIT DOWN
FLEXIBLE RACEWAY
RACEWAY EXPOSED
CONDUIT UP
GENERAL EQUIPMENT
PANELBOARD-250 VAC OR LESS
SURFACE MOUNTED
PANELBOARD-250 VAC OR LESS
RECESSED
PANELBOARD-OVER 250 VAC
SURFACE MOUNTED
PANELBOARD-OVER 250 VAC
RECESSED
TRANSFORMER
DISCONNECT SWITCH: "F" IF FUSED
FRAME AMPS/POLES/NEMA TYPE
FUSE PER MANUFACTURERS RECOMMENDATIONS
ENCLOSED BREAKER-RECESSED IN WALL
ENCLOSED CIRCUIT BREAKER
EMERGENCY PUSHBUTTON
CABLE TRAY
COMBINATION STARTER AND DISCONNECT
EXHAUST FAN
MANUAL STARTER AND MOTOR RATED SWITCH
MOTOR
JUNCTION BOX - WALL/CEILING/FLOOR
SURGE SUPPRESSOR
BACKBOARD
FIRE PROTECTION EQUIPMENT
COMMUNICATIONS
VOICE OUTLET, QUANTITY OF JACKS AS NOTED
DATA OUTLET, QUANTITY OF JACKS AS NOTED
COMBINATION VOICE/DATA OUTLET, QUANTITY OF
VOICE/DATA JACKS AS NOTED
BOX, STUB-UP, AND MODULAR PLATE W/ BLANKS
TELEVISION OUTLET
SLAB OR BELOW GRADE
GROUNDING CONDUCTOR- UNDER
GROUND CONNECTION (SCHEMATIC)
CONCEALED IN ROOF OR WALLS
GROUNDING CONDUCTOR-
GROUNDING CONDUCTOR- EXPOSED
GROUNDING PLATE
F
FACP
FAA
BT
C
C
WF
VS
DH
BRSMOKE DETECTOR/SENSOR - BEAM RECEIVER
SMOKE DETECTOR/SENSOR - BEAM TRANSMITTER
SPEAKER/VISUAL ALARM: CEILING/WALL
VISUAL ALARM: CEILING/WALL
AUDIO/VISUAL ALARM: CEILING/WALL
MANUAL PULL STATION
FIRE ALARM ANNUNCIATOR
FIRE ALARM PANELDUCT MOUNTED SMOKE DETECTOR
SMOKE DETECTOR: CEILING / WALL
HEAT DETECTOR: CEILING / WALL
WATER FLOW SWITCH
WATER TAMPER SWITCH
DOOR HOLDER
FIREMAN’S PHONE OUTLET
A/V BACKBOX
J
J
x.x.x
x.x.x
3.5" DEPTH IF ONLY TWO NUMBERS ARE SHOWN
JUNCTION BOX: WIDTH.HEIGHT.DEPTH: FLOOR/WALL
MOUNT AT RECEPTACLE HEIGHT UNLESS NOTED
PROVIDE PULLSTRINGS IN ALL UNUSED OR SPARE CONDUIT.
SEAL ALL CONDUIT PENETRATIONS WITH ACOUSTICAL SEALANT. MAINTAIN FIRE RATINGS.
PROVIDE BUSHINGS ON ALL CONDUIT ENDS.
ALL BACKBOXES SHALL BE FLUSH MOUNTED UNLESS OTHERWISE NOTED.
COORDINATE FLOORBOX FACEPLATE COLORS WITH THE ARCHITECT PRIOR TO PURCHASE.
NOTES
OTHERWISE
" EMT UNLESS OTHERWISE NOTED.3/4ALL CONDUIT SHALL BE
ALL BACKBOXES ARE AT TYPICAL RECEPTACLE HEIGHT UNLESS OTHERWISE NOTED.
OTHERWISE.
CONDUIT FROM BOXES IS TO BE ROUTED ABOVE THE ACCESSIBLE CEILING ONLY, UNLESS NOTED SPECIFICALLY
LIGHTING FIXTURE SCHEDULE
MARK LAMPS FIXTURE TYPE-SEE SPECIFICATIONS MOUNTING REMARKSVOLT.
WHERE BACKBOXES ARE SHOWN AT COUNTERTOP OR CASEWORK, BOXES SHALL BE MOUNTED BELOW
THE COUNTERTOP @ 18" AFF UNLESS NOTED OTHERWISE.
GROUNDING
GROUND ROD
ELECTRICAL
SCHEDULE -
LEGEND &
ABC
X-1
E
D
B
A
ABCDEFGHIJKLMNOPQRSTUVWXYZ ABC
CER SERIES BY COMPASS
VA4 SERIES BY BEGHELLI
LPX7 SERIES BY Sure Lites
RED LETTERS
LITHONIA LQM SERIES
THERMOPLASTIC EXIT
NS40 2 2 26TRT UN BY HUBBELL
SMSQ12-226T-120 BY WILLIAMS
FS-P-226-UNV-EBT2 BY Fail-Safe
LITHONIA VRR-2/26TRT-120-HEB-EC
SQUARE CANOPY FIXTURE
CS 4 232 E U / CS WG4 LPT835 BY COLUMBIA
77-4-2-32-WG-7714-EB2 BY WILLIAMS
SNF-232-UNV-EB81 with WG/SNF-4FT BY Metalux
LITHONIA L232-2-48-32-120-277
WITH WIREGUARD
1X4 FLUORESCENT INDUSTRIAL STRIP
ST8 24 2 32 G FS A12125 E U BY COLUMBIA
50G-S24-232-S-A12125-EB2-120 BY WILLIAMS
2GC-232A125-UNV-EB81 BY Metalux
LITHONIA 2SP-2-32-A12125
2X4 LENSED FLUORESCENT TROFFER
HETG-S24-232-A-EB2-120 BY WILLIAMS
EPC 24 228 G SH EP95 F5835 BY COLUMBIA
2AC-228T5-UNV-EBT1 BY Metalux
LITHONIA 2RT5-28T5-MVOLT-GEB95-LPM835P
2X4 LENSED FLUORESCENT TROFFER
ABCDEFGHI
WALL
CANOPY
UNDER
SURFACE
A.F.F.
@ 8’-0"
OR CHAIN
SURFACE
GRID
RECESSED
GRID
RECESSED
ABCDEFGHIJK
CONFIGURABLE
FIELD
BATTERY
EM
WITH
A12 LENS
.125" THICK
ABCDEFGHI
LED
FLUOR
TRT
2-26W
3500K
FLUOR
2-32W
3500K
FLUOR
2-32W
3500K
FLUOR
T5
2-28W
ABCD
BY:
EQUALS
120
BY:
EQUALS
120V
BY:
EQUALS
120V
BY:
EQUALS
120V
BY:
EQUALS
120V
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JCW
TWT
14640GILEAD
1-29-16
KITCHEN
G106
GYMNASIUM
G107
CORRIDOR
G110MEN’S
G111
ROOM
LOCKER
G112
ROOM
HOME TEAM
G113
JAN
G114
SUPPLY
G115
CLOSET
G116
TEAM ROOM
VISITING
G117
CORRIDOR
G118WOMEN’S
G119
ROOM
LOCKER
G120
CORRIDOR
G121
YOGA ROOM
G124
CLASSROOM
G125
CLASSROOM
G126
UTILITY
G127
TRAINING
WEIGHT
G123
EXISTING RAMPEXERCISE
AEROBIC
G122
WORK AT THIS AREA
NO SCOPE OF
IN THIS AREA
NO SCOPE OF WORK
DECK TO REMAIN
EXISTING CONC.
CONSTRUCTION
PHASE II
FACP
GL1
1SCALE:
1= 1’-0
88 0 4 8 16
NE201GYMNASIUM - NEW WORK - LIGHTING
LIGHTING
NEW WORK -
GYMNASIUM -
LINE LEGEND
EXISTING TO REMAIN
NEW WORK
A A A A
AA A A
A A A
A A A
A
A
A
A
B B
A A
AA
A A
A A
AA
A A
A A
AA
A A
A A
AA
A A
B
II
X-1
X-1X-1
33
33
3 3
33
X-1
33
33
3 3
33
II
II
I I
X-1
X-1
X-1
X-1
K
K
U
U
SENSING.
UNSWITCHED LEG OF CIRCUIT SERVING LIGHTS IN THE AREA FOR POWER LOSS
EMERGENCY FIXTURES SHALL BE PROVIDED WITH AN EMERGENCY BATTERY AND
INPUT FROM ANY OF THE SENSORS SHALL ACTIVATE THE CIRCUIT.
SENSORS ARE SHOWN IN ONE ROOM, SENSORS SHALL BE TIED TOGETHER,
PLACED AND SELECTED PER MANUFACTURER’S SHOP DRAWINGS. WHERE MULTIPLE
OCCUPANCY SENSOR ARE SHOWN AS AN INTENT GUIDE ONLY, SENSORS SHALL
DEDICATED NEUTRALS FOR ALL BRANCH CIRCUITS.
CONSOLIDATION OF HOMERUNS IS ACCEPTABLE UP TO THREE CIRCUITS. PROVIDE
A
B
C
D
GENERAL NOTES:(THIS SHEET ONLY)
POWER.
HOT FOR SENSING POWER LOSS. LIGHT SHALL REMAIN ILLUMINATED UPON LOSS OF
PROVIDE AN EMERGENCY BATTERY BALLAST FOR THIS FIXTURE. PROVIDE AN UNSWITCHED
ACTIVATE ALL OF THE LIGHTS.
OCCUPANCY SENSORS SHALL WORK IN PARALLEL SUCH THAT INPUT FROM EITHER WILL
1
2
3
4
NOTES:(THIS SHEET ONLY)
1
1
REMAINING LIGHTS.
ROW OF LIGHTS OFF DURING PROJECTOR USE AND SEPARATELY SWITCH THE
THE GOAL OF THE LIGHTING DESIGN IN THE CLASSROOMS IS TO SWITCH THE FRONT
LOSS OF POWER, FIXTURE SHALL ILLUMINATE REGARDLESS OF SWITCH POSITION.
BALLAST FOR THIS FIXTURE. PROVIDE AN UNSWITCHED HOT FOR SENSING POWER LOSS. UPON
LIGHT FIXTURE SHALL SWITCH WITH ROOM LIGHTS. PROVIDE AN EMERGENCY BATTERY
IN THE "ON" POSITION, THE SENSOR CONTROLS THE LIGHTS.
CLASSROOM. PROVIDE SWITCHING AT THE DOOR IN ORDER TO FORCE THE LIGHTS "OFF".
PROVIDE COMBINATION ULTRASOUND/INFRARED SENSOR TO CONTROL THE LIGHTS IN THE
2
2
1
2
2
2
2
22
X-1
B B
B B
UI
UI UI
UI UI
UI UI
UI
UI
UIUI
33
33
3
33
33
3
3
4
4
4
4
4
4
U
4
BB
B
2
BB
BB
UI
UI
UI
2
12
GL1-11
12
GL1-13
GL1-15
D
D
2
44
4
GL1-17
GL1-19
A
A
A
A
A
A
A
A
A
A
A
A
B
UI
2 B
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JCW
TWT
14640GILEAD
1-29-16
CLASSROOM
M101
ELEC
M102
UTILITY
M103
JAN
M104
CORRIDOR
M105
WORKROOM
M106
ROOM
RESOURCE
M107CLASSROOM
M108
CORRIDOR
M109
CLASSROOM
M110
CLASSROOM
M111
BOYS
M112
GIRLS
M113
CLASSROOM
M116
RESTROOM
H/C
M114
CLOSET
M115
DROP-OFF TO REMAIN
COVERED
CLASSROOM
S101
CLOSET
S102
LAB
SCIENCE
S103
CLASSROOM
S104
MENS
S105
WOMENS
S106ELECT
S107
WH
SL1
SMDP
CMDP
CL1
2SCALE:
1= 1’-0
88 0 4 8 16
N1
SCALE:1
= 1’-08
8 0 4 8 16
NSTEM BUILDING - NEW WORK - LIGHTING MIDDLE SCHOOL - NEW WORK - LIGHTING
LIGHTING
NEW WORK -
BUILDINGS -
SCHOOL
E202
LINE LEGEND
EXISTING TO REMAIN
NEW WORK
A A A
AAA
A A A A
A AA A A
A A A
A A A
A A A
A A A
A A A
B B
A A A A
A A AB
A A AB
A A A A A A A A A A
A A
A A A
A A A
AA
A
A
A
A
A
A
A A
AA
A A
A A A
A A A
AA
A
A
E E
E E
UI
UI
SENSING.
UNSWITCHED LEG OF CIRCUIT SERVING LIGHTS IN THE AREA FOR POWER LOSS
EMERGENCY FIXTURES SHALL BE PROVIDED WITH AN EMERGENCY BATTERY AND
INPUT FROM ANY OF THE SENSORS SHALL ACTIVATE THE CIRCUIT.
SENSORS ARE SHOWN IN ONE ROOM, SENSORS SHALL BE TIED TOGETHER,
PLACED AND SELECTED PER MANUFACTURER’S SHOP DRAWINGS. WHERE MULTIPLE
OCCUPANCY SENSOR ARE SHOWN AS AN INTENT GUIDE ONLY, SENSORS SHALL
DEDICATED NEUTRALS FOR ALL BRANCH CIRCUITS.
CONSOLIDATION OF HOMERUNS IS ACCEPTABLE UP TO THREE CIRCUITS. PROVIDE
A
B
C
D
GENERAL NOTES:(THIS SHEET ONLY)
POWER.
HOT FOR SENSING POWER LOSS. LIGHT SHALL REMAIN ILLUMINATED UPON LOSS OF
PROVIDE AN EMERGENCY BATTERY BALLAST FOR THIS FIXTURE. PROVIDE AN UNSWITCHED
ACTIVATE ALL OF THE LIGHTS.
OCCUPANCY SENSORS SHALL WORK IN PARALLEL SUCH THAT INPUT FROM EITHER WILL
1
2
3
4
NOTES:(THIS SHEET ONLY)
REMAINING LIGHTS.
ROW OF LIGHTS OFF DURING PROJECTOR USE AND SEPARATELY SWITCH THE
THE GOAL OF THE LIGHTING DESIGN IN THE CLASSROOMS IS TO SWITCH THE FRONT
LOSS OF POWER, FIXTURE SHALL ILLUMINATE REGARDLESS OF SWITCH POSITION.
BALLAST FOR THIS FIXTURE. PROVIDE AN UNSWITCHED HOT FOR SENSING POWER LOSS. UPON
LIGHT FIXTURE SHALL SWITCH WITH ROOM LIGHTS. PROVIDE AN EMERGENCY BATTERY
IN THE "ON" POSITION, THE SENSOR CONTROLS THE LIGHTS.
CLASSROOM. PROVIDE SWITCHING AT THE DOOR IN ORDER TO FORCE THE LIGHTS "OFF".
PROVIDE COMBINATION ULTRASOUND/INFRARED SENSOR TO CONTROL THE LIGHTS IN THE
2
2
3
3
UI2
2
UI
UI
2
2
2
UI
UI
X-1
X-1
UI
UI 2
2
U
X-1
K
X-2 X-1
K
K
U
X-1
BB
B B
BB
K
U
U
UI
UI
U
U
X-1
X-1
D D
D D
D D
I
I
2
1 1
1
1 1
UI
UI UI
UIK
K
2
2
2
2UI
UI
PE
2
UI
UI
UI
UI
3
3
3
3
3
3
3
3
33
3
3
33
3
3
SL1-1
SL1-3
CL1-1
CL1-3
CL1-5
CL1-7
CL1-9
11
1
2
CL1-11
PHOTOCELL ON/OFFCL1-13
LC
LC
PE
D
A
B B2
A
A
A
UI UI
2 2
A
5
CONDITION.
CONDUIT AND CONDUCTORS BACK TO SERVING PANEL AND RETURN FIXTURE TO OPERABLE
PREVIOUSLY BEEN CUT AND FIXTURE CURRENTLY IS NOT OPERABLE. REPLACE DEFECTIVE
EXISTING FIXTURE TO BE REUSED. SUPPORTING CONDUIT AND CONDUCTORS HAVE
5
6 EXISTING FIXTURE TO REMAIN.
6
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JCW
TWT
14640GILEAD
1-29-16
KITCHEN
G106
GYMNASIUM
G107
CORRIDOR
G110MEN’S
G111
ROOM
LOCKER
G112
ROOM
HOME TEAM
G113
JAN
G114
SUPPLY
G115
CLOSET
G116
TEAM ROOM
VISITING
G117
CORRIDOR
G118WOMEN’S
G119
ROOM
LOCKER
G120
CORRIDOR
G121
YOGA ROOM
G124
CLASSROOM
G125
CLASSROOM
G126
UTILITY
G127
TRAINING
WEIGHT
G123
EXISTING RAMPEXERCISE
AEROBIC
G122
WORK AT THIS AREA
NO SCOPE OF
IN THIS AREA
NO SCOPE OF WORK
DECK TO REMAIN
EXISTING CONC.
CONSTRUCTION
PHASE II
1SCALE:
1= 1’-0
88 0 4 8 16
NE301
LINE LEGEND
EXISTING TO REMAIN
NEW WORK
GYMNASIUM - NEW WORK - POWER/TELECOM
TO BE GFI STYLE. PROVIDE LABELS ON THE RECEPTACLE COVER TO INDICATE THIS PROTECTION.
WHERE OUTLETS ARE SHOWN SERVED FROM GFI BREAKERS, THE INDIVIDUAL OUTLETS ARE NOT REQUIRED
DIMENSION OUTLETS FROM THE ELECTRICAL SHEETS.
LOCATE ALL DATA AND RECEPTACLE OUTLETS PER ARCHITECTURAL CASEWORK ELEVATIONS. DO NOT
RESTROOMS, AND IN EXTERIOR LOCATIONS SHALL BE GFCI TYPE.
ALL RECEPTACLES LOCATED WITHIN SIX FEET OF A WATER SOURCE AND ALL RECEPTACLES IN KITCHENS,
AV EQUIPMENT.
COORDINATE WITH AV FOR CONDUITS, BACKBOXES, FLOORBOXES AND POWER/DATA NEEDS FOR ALL
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL INFRASTRUCTURE FOR AV EQUIPMENT.
GENERAL NOTES:(THIS SHEET ONLY)
A
B
C
D
E
CHANNEL RACEWAY TO ABOVE THE CEILING.
-WHERE POWER AND DATA ARE SHOWN ADJACENT, USE THE WIRE MOLD 2000 SERIES WITH DUAL
T0 ABOVE THE CEILING.
-WHERE RECEPTACLES ALONE ARE SHOWN ON EXISTING WALLS, USE THE WIRE MOLD V700 SERIES
WALLS, PROVIDE WIRE MOLD PRODUCTS AS FOLLOWS:
WHERE POSSIBLE, NEW DEVICES SHALL BE FLUSH MOUNTED. WHERE NEW DEVICES ARE SHOWN ON EXISTING F
CIRCUIT. PROVIDE A RED LABEL WITH WHITE LETTERS ADJACENT TO READ "FIRE ALARM PANEL".
CIRCUIT FOR FIRE ALARM PANEL. PROVIDE A RED LOCKING DEVICE OVER THE BREAKER SERVING THIS 1
NOTES:(THIS SHEET ONLY)
GL1
EXISTING TO REMAIN GMSB
FACP
FIRE ALARM SYSTEM
EXISTING TO REMAIN
SERVICE DISCONNECTGYMNASIUM MAIN
2
WITH ARCHITECT PRIOR TO ROUGHING.
RECEPTACLE FOR TV MONITOR. COORDINATE EXACT LOCATION AND HEIGHT ABOVE LAY-IN CEILING
1
3
5
2
79
1
BE SHARED.
IS ACCEPTABLE UP TO THREE CIRCUITS. PROVIDE DEDICATED NEUTRALS, EQUIPMENT GROUND MAY
PANEL GL1. THE NUMBER ADJACENT INDICATES THE CIRCUIT NUMBER. CONSOLIDATION OF HOMERUNS
WITH NEW 20A RATED DUPLEX. NEW RECEPTACLES SHOWN ON THIS SHEET ARE SERVED FROM
TO BE REUSED. PROVIDE AN ALLOWANCE TO REPLACE UP TO 10 DAMAGED RECEPTACLES/COVERS
EXISTING RECEPTACLES AND THEIR SUPPORTING ENCLOSURES AND CONDUCTORS BACK TO PANEL
1
3
22
2
2
2
2
2
2
2
2
2
2
2
POWER/TELECOM
NEW WORK -
GYMNASIUM -
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JCW
TWT
14640GILEAD
1-29-16
CLASSROOM
M101
ELEC
M102
UTILITY
M103
JAN
M104
CORRIDOR
M105
WORKROOM
M106
ROOM
RESOURCE
M107CLASSROOM
M108
CORRIDOR
M109
CLASSROOM
M110
CLASSROOM
M111
BOYS
M112
GIRLS
M113
CLASSROOM
M116
RESTROOM
H/C
M114
CLOSET
M115
DROP-OFF TO REMAIN
COVERED
CLASSROOM
S101
CLOSET
S102
LAB
SCIENCE
S103
CLASSROOM
S104
MENS
S105
WOMENS
S106ELECT
S107
WH
2SCALE:
1= 1’-0
88 0 4 8 16
N1
SCALE:1
= 1’-08
8 0 4 8 16
N
E302
LINE LEGEND
EXISTING TO REMAIN
NEW WORK
TO BE GFI STYLE. PROVIDE LABELS ON THE RECEPTACLE COVER TO INDICATE THIS PROTECTION.
WHERE OUTLETS ARE SHOWN SERVED FROM GFI BREAKERS, THE INDIVIDUAL OUTLETS ARE NOT REQUIRED
DIMENSION OUTLETS FROM THE ELECTRICAL SHEETS.
LOCATE ALL DATA AND RECEPTACLE OUTLETS PER ARCHITECTURAL CASEWORK ELEVATIONS. DO NOT
RESTROOMS, AND IN EXTERIOR LOCATIONS SHALL BE GFCI TYPE.
ALL RECEPTACLES LOCATED WITHIN SIX FEET OF A WATER SOURCE AND ALL RECEPTACLES IN KITCHENS,
AV EQUIPMENT.
COORDINATE WITH AV FOR CONDUITS, BACKBOXES, FLOORBOXES AND POWER/DATA NEEDS FOR ALL
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL INFRASTRUCTURE FOR AV EQUIPMENT.
GENERAL NOTES:(THIS SHEET ONLY)
A
B
C
D
E
CHANNEL RACEWAY TO ABOVE THE CEILING.
-WHERE POWER AND DATA ARE SHOWN ADJACENT, USE THE WIRE MOLD 2000 SERIES WITH DUAL
T0 ABOVE THE CEILING.
-WHERE RECEPTACLES ALONE ARE SHOWN ON EXISTING WALLS, USE THE WIRE MOLD V700 SERIES
WALLS, PROVIDE WIRE MOLD PRODUCTS AS FOLLOWS:
WHERE POSSIBLE, NEW DEVICES SHALL BE FLUSH MOUNTED. WHERE NEW DEVICES ARE SHOWN ON EXISTING F
SL1
SMDP
CMDP
CL1
LINE ARE SERVED BY PANEL SL1
ALL RECEPTACLES WITHIN THIS
LINE ARE SERVED BY PANEL CL1
ALL RECEPTACLES WITHIN THIS
BE SHARED.
IS ACCEPTABLE UP TO THREE CIRCUITS. PROVIDE DEDICATED NEUTRALS, EQUIPMENT GROUND MAY
INDICATED. THE NUMBER ADJACENT INDICATES THE CIRCUIT NUMBER. CONSOLIDATION OF HOMERUNS
20A RATED DUPLEX. NEW RECEPTACLES SHOWN ON THIS SHEET ARE SERVED FROM THE PANEL
TO BE REUSED. PROVIDE AN ALLOWANCE TO REPLACE UP TO 10 DAMAGED RECEPTACLES WITH NEW
EXISTING RECEPTACLES AND THEIR SUPPORTING ENCLOSURES AND CONDUCTORS BACK TO PANEL
1
NOTES:(THIS SHEET ONLY)
FA
CP
1
FA
CP
1
SL1-2
CL1-2
ALARM PANEL, "
CIRCUIT. PROVIDE A RED LABEL WITH WHITE LETTERS ADJACENT BREAKER SERVING IT TO READ "FIRE
CIRCUIT FOR FIRE ALARM PANEL. PROVIDE A RED LOCKING DEVICE OVER THE BREAKER SERVING THIS
STEM BUILDING - NEW WORK - POWER/TELECOM MIDDLE SCHOOL - NEW WORK - POWER/TELECOM
POWER/TELECOM
NEW WORK -
BUILDINGS -
SCHOOL
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JCW
TWT
14640GILEAD
1-29-16
KITCHEN
G106
GYMNASIUM
G107
CORRIDOR
G110MEN’S
G111
ROOM
LOCKER
G112
ROOM
HOME TEAM
G113
JAN
G114
SUPPLY
G115
CLOSET
G116
TEAM ROOM
VISITING
G117
CORRIDOR
G118WOMEN’S
G119
ROOM
LOCKER
G120
CORRIDOR
G121
YOGA ROOM
G124
CLASSROOM
G125
CLASSROOM
G126
UTILITY
G127
TRAINING
WEIGHT
G123
EXISTING RAMPEXERCISE
AEROBIC
G122
WORK AT THIS AREA
NO SCOPE OF
IN THIS AREA
NO SCOPE OF WORK
DECK TO REMAIN
EXISTING CONC.
CONSTRUCTION
PHASE II
EWH-1
AC-1
AC-2
AC-3
AC-4
AC-5
AC-6
AC-7
EWH-2
EF-2EF-2
EWH-3
EWH- 4
EWH-6
EWH-5
GL1
1SCALE:
1= 1’-0
88 0 4 8 16
NE401
LINE LEGEND
EXISTING TO REMAIN
NEW WORK
GYMNASIUM - NEW WORK - HVAC POWER/SYSTEMS
SYSTEMS
POWER/
HVAC
NEW WORK -
GYMNASIUM -
EXISTING TO REMAIN GMSB
SERVICE DISCONNECTGYMNASIUM MAIN
FACP
F
60A/3P/NEMA 3R
GL1-2
FGL1-8
60A/3P/NEMA 3R
FGL1-14
60A/3P/NEMA 3R
FGL1-20
60A/3P/NEMA 3R
FGL1-26
60A/3P/NEMA 3R
FGL1-32
60A/3P/NEMA 3R
FGL1-38
60A/3P/NEMA 3R
F
F
GENERAL NOTES:(THIS SHEET ONLY)
A
ALIGN FIRE ALARM DEVICES WITH POWER OUTLETS BELOW.
WHICH EVER IS LOWER. ALL MANUAL PULL STATIONS ARE TO BE MOUNTED 45" AFF. WHERE POSSIBLE
FIRE ALARM STROBE SIGNALS SHALL BE MOUNTED 80" AFF TO BOTTOM OF LENS, OR 6" BELOW CEILING,
FIRE ALARM CONDUIT AND BOXES SHALL BE PAINTED RED COLOR.
FIRE ALARM DEVICES SHALL BE WHITE COLOR.
B
C
F
F
F
F
GL1-31
GL1-37
FIRE ALARM SYSTEM
EXISTING TO REMAIN
NOTES:(THIS SHEET ONLY)
1
SYSTEM. NEW DEVICES SHALL BE BY SAME MANUFACTURER AS EXISTING SYSTEM.
ROUTE ALL NEW FIRE ALARM DEVICES BACK TO THE EXISTING TO REMAIN FIRE ALARM
1
GL1-55
GL1-61M
GL1-46
GL1-49
GL1-43
M
GL1-44
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JCW
TWT
14640GILEAD
1-29-16
CLASSROOM
M101
ELEC
M102
UTILITY
M103
JAN
M104
CORRIDOR
M105
WORKROOM
M106
ROOM
RESOURCE
M107CLASSROOM
M108
CORRIDOR
M109
CLASSROOM
M110
CLASSROOM
M111
BOYS
M112
GIRLS
M113
CLASSROOM
M116
RESTROOM
H/C
M114
CLOSET
M115
DROP-OFF TO REMAIN
COVERED
CLASSROOM
S101
CLOSET
S102
LAB
SCIENCE
S103
CLASSROOM
S104
MENS
S105
WOMENS
S106ELECT
S107
WH
AC-8
AC-9
AC-10
AC-1 1
EWH-7
AC-13 AC-14 AC-15
AC-12
EF-3
EWH-8
EWH-9
PTAC-1 PTAC-2 PTAC-3
EWH-10
EWH-11
SL1
SMDP
CMDP
CL1
2SCALE:
1= 1’-0
88 0 4 8 16
N1
SCALE:1
= 1’-08
8 0 4 8 16
N
E402
LINE LEGEND
EXISTING TO REMAIN
NEW WORK
GENERAL NOTES:(THIS SHEET ONLY)
STEM BUILDING - NEW WORK - HVAC POWER/SYSTEMS MIDDLE SCHOOL - NEW WORK - HVAC POWER/SYSTEMS
SYSTEMS
POWER/
HVAC
NEW WORK -
BUILDINGS -
SCHOOL
FSMDP-2
60A/3P/NEMA 3R
F
60A/3P/NEMA 3R
CMDP-2
F
60A/3P/NEMA 3R
FSMDP-8
60A/3P/NEMA 3R
F60A/3P/NEMA 3R
F
60A/3P/NEMA 3R
F
60A/3P/NEMA 3R
F
60A/3P/NEMA 3R
SMDP-14
CMDP-8
CMDP-14 CMDP-20 CMDP-26
CMDP-25
NEMA 6-20R
CMDP-33
NEMA 6-20R
CMDP-29
CMDP-32
CMDP-38
CMDP-37
F
F
F
F
FA
CP
FA
CP
TO THE FIRE ALARM PANEL.
COORDINATE ALL TAMPER/FLOW SWITCHES WITH THE SPRINKLER INSTALLER. BOTH REQUIRE A CONNECTION
A
ALIGN FIRE ALARM DEVICES WITH POWER OUTLETS BELOW.
WHICH EVER IS LOWER. ALL MANUAL PULL STATIONS ARE TO BE MOUNTED 45" AFF. WHERE POSSIBLE
FIRE ALARM STROBE SIGNALS SHALL BE MOUNTED 80" AFF TO BOTTOM OF LENS, OR 6" BELOW CEILING,
FIRE ALARM CONDUIT AND BOXES SHALL BE PAINTED RED COLOR.
FIRE ALARM DEVICES SHALL BE WHITE COLOR.
B
C
D
M
CMDP-19CMDP-13
CL1-4
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JCW
TWT
14640GILEAD
1-29-16
E501
ELECTRICAL
DIAGRAMS-
RISER
1
GMSB
GYMNASIUM - RISER DIAGRAM - ELECTRICAL
EXISTING TO REMAIN
800A/3P/NEMA 3R
SERVICE DISCONNECT
GYMNASIUM MAIN
TO REMAIN
EXISTING
208V/3P
800A
3
CMDP
NOT TO SCALE
NOT TO SCALE
CMDP
400A
CL1
200A
AND TRANSFORMER BANK
EXISTING TO REMAIN POLE
FOR DAMAGE
SERVICE ENTRANCE CABLE
WEATHERHEAD AND AERIAL
INSPECT EXISTING TO REMAIN
2
SMDP
STEM BUILDING - RISER DIAGRAM - ELECTRICAL
NOT TO SCALE
SMDP
400A
SL1
200A
AND TRANSFORMER BANK
EXISTING TO REMAIN POLE
FOR DAMAGE
SERVICE ENTRANCE CABLE
WEATHERHEAD AND AERIAL
INSPECT EXISTING TO REMAIN
CLASSROOM BUILDING - RISER DIAGRAM - ELECTRICAL
EXISTING ELECTRICAL ROOM EXISTING HALLWAY
THE DOOR.
THE NEW INFILL PANEL REPLACING
INSTALL FLUSHMOUNT PANEL WITHIN
GL1
400A
NEW BREAKER SHALL MATCH KAIC RATING OF EXISTING PANEL.
PROVIDE A NEW 400A/3P BREAKER IN EXISTING PANEL.
AND TRANSFORMER BANK
EXISTING TO REMAIN POLE
4#600 KCMIL, 1#3G, 4"C
REAR BUILDING FASCADE
PE
1
LC
2
REAR BUILDING FASCADE
PE
1
LC
2
PROVIDE WITH HAND/AUTO/OFF CONTROL ON BOX FRONT.
PROVIDE A 4 POLE LIGHTING CONTACTOR WHICH WILL ACCEPT INPUT FROM PHOTOCELL.
NOTES:(THIS SHEET ONLY)
1
2
WITH STAINLESS STEEL COVER. P.E. SHALL PROVIDE INPUT TO LIGHTING CONTACTOR.
OF MAN MADE LIGHT SOURCES. J-BOX TO HOUSE P.E CELL SHALL BE RECESSED MOUNTED
PROVIDE DUSK-TIL-DAWN PHOTOELECTRIC CELL. LOCATE P.E. CELL FACING NORTH, CLEAR
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JCW
TWT
14640GILEAD
1-29-16
E601
Switch
Local
Red (Line)
Re
d
POWER PACK
BlkHot
Wht
Red (Load)
Blk
Blu
White (Neutral)
Off
AD
OL
Control Output
+24VDC
Common
Occupancy
Any 3-Wire
Control Output
+24VDC
Common
Sensor
24VDC
Occupancy
Any 3-Wire
Control Output
+24VDC
Common
Sensor
24VDC
Occupancy
Any 3-Wire
Sensor
24VDC
Maximum number of sensors per Power Pack
depends on the sensors used. See the product
data sheet to determine the current
consumption of each sensor.
MULTIPLE OCCUPANCY SENSORS USING ONE POWER PACK 3
NOT TO SCALE
SENSOR INSTALLATION 1
NOT TO SCALE
Ceiling Mounted
(Ribbon Cable)
Low Voltage 8-Wire
Mounting Bracket
Ceiling Tile
Mounting
Height
Parallel
To Vertical
At 10 Foot
NOT TO SCALE
BALLAST
LAMPS
BATTERY
INVERTER
B
W
G
R/O
B
W
G
R/O
HOT
WALL SWITCHED
NEUTRAL
GROUND
G W B W GB W/
O
R/
O
LIGHT FIXTURE
BATTERY / INVERTER PACK
"HOT" CHARGES BATTERY AND HOLDS THE RELAY.
"SWITCHED" CONNECTS THRU RELAY TO FIXTURE.
IF HOT FAILS, THEN RELAY CONNECTS FIXTURE
TO BATTERY / INVERTER.
BALLAST
LAMPS
G W B
LIGHT FIXTURE
1 1
BOX PROVIDED ON FIXTURE
TYPICAL
SWITCHED
FIXTURE
TYPICAL SWITCHED
FIXTURE WITH
BATTERY BACKUP
PROVIDE BOTH "HOT" AND "UNSWITCHED"
CONDUCTORS IN ALL LIGHTING CIRCUITS.
CONNECT "NIGHT LIGHT" FIXTURES TO
"HOT" RATHER THAN "SWITCHED"
CONDUCTORS. COORDINATE WITH ARCHITECT.
NOTES:(THIS DETAIL ONLY)
1
1
White (Neutral)
POWER PACK
Hot Blk
Wht
Red (Line)
Blk
Re
d
Blu
Switch
Red (Load)
Off
Local
AD
OL
AD
OL
Switch
Local
Off
+24VDC
Control Output
Common24VDC
Sensor
Any
24VDC SENSOR CONTROLLING DUAL LEVEL LIGHTING 4
NOT TO SCALE
ELECTRICAL
DETAILS -
2IN LIGHT FIXTURE WITH M.C. CABLE OR NM CABLE
TYPICAL BATTERY BACK-UP
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JCW
TWT
14640GILEAD
1-29-16
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
PO
LE
41
39
37
35
33
31
29
27
25
23
21
19
17
15
13
11
9
7
5
3
1
38
32
26
20
14
8
2
CKT
PANEL
NOTES
Minimum KAIC:
37
31
29
27
25
23
21
19
17
15
13
11
9
7
5
3
1
CKT
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
TRIP
208
4#10
4#10
#12
#12
#12
#12
#12
#12
#12
#12
#12
#12
WIRE
120
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
CD.
4
3
MULTISECTION CONN AMPS
MULTISECTION CONN V A
PANEL SECTION CONN AMPS
PANEL SECTION CONN V A
EWH-2
EWH-1
SPARE
SPARE
SPARE
SPARE
SPARE
LTS-G121
LTS-G122
LTS-G123
LTS-G126, 125, 124
LTS-G120
TV MONITOR - G126
TV MONITOR - G125
TV MONITOR - G124
TV MONITOR - G123
TV MONITOR - G122
SERVES
WIRE
PH,
1500
1500
1500
1500
1500
1500
600
1056
1056
1584
928
200
200
200
400
400
AMPS
VOLT-
EXISTING
NEW
400
47979
345
41451
6544
6544
5044
5644
6987
5244
5444
A
PHASE LOAD V.A.
390
46851
336
40323
6544
6544
5044
5044
6459
5244
5444
B
FED BY
390
46851
340
40851
6544
6544
5044
5044
6459
5972
5244
C
GMSB
LOCATION: UTILITY G127
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
5044
5044
5044
5044
5044
5044
5044
5044
5044
5044
5044
5044
5403
5403
5403
5044
5044
5044
5044
5044
5044
AMPS
VOLT-
AC-7 (G122)
AC-6 (G122)
AC-5 (G123)
AC-4 (G123)
AC-3 (G124)
AC-2 (G125)
AC-1 (G126)
SERVES
1"
1"
1"
1"
1"
1"
1"
CD.
MCB
1#10G
4#6
1#10G
4#6
1#10G
4#6
1#10G
4#6
1#10G
4#6
1#10G
4#6
1#10G
4#6
WIRE
FLUSH
400
45
45
45
45
45
45
45
TRIP
MOUNTED
AMPS
3
3
3
3
3
3
3
3
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
/
41
39
37
35
33
31
29
27
25
23
21
19
17
15
13
11
9
7
5
3
1
LOCATION: UTILITY G127
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
PANEL
41
39
37
35
33
31
29
27
25
23
21
19
17
15
13
11
9
7
5
3
1
LOCATION: ELECTRICAL 5
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
PANEL SMDP
41
39
37
35
33
31
29
27
25
23
21
19
17
15
13
11
9
7
5
3
1
PANEL SL1
41
39
37
35
33
31
29
27
25
23
21
19
17
15
13
11
9
7
5
3
1
LOCATION: ELECTRICAL 10
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
PANEL CMDP
23
2764
23
2764
0
0
0
0
280
1232
1252
A
PHASE LOAD V.A.
22
2592
22
2592
0
0
0
0
0
1232
1360
B
FED BY
16
1878
16
1878
0
0
0
0
0
1350
528
C
SMDP
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
CKT
PANEL CL1
GL1 Sec_1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
GL1 Sec_2
NOTES
Minimum KAIC:
79
73
67
61
55
49
43
CKT
20
20
20
20
20
20
20
TRIP
208
4#10
4#10
4#10
4#10
WIRE
120
1/2"
1/2"
1/2"
1/2"
CD.
4
3
MULTISECTION CONN AMPS
MULTISECTION CONN V A
PANEL SECTION CONN AMPS
PANEL SECTION CONN V A
SPARE
SPARE
SPARE
EWH-6
EWH-5
EWH-4
EWH-3
SERVES
WIRE
PH,
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
AMPS
VOLT-
EXISTING
NEW
400
47979
54
6528
0
0
0
1500
1500
1500
2028
A
PHASE LOAD V.A.
390
46851
54
6528
0
0
0
1500
1500
1500
2028
B
FED BY
390
46851
50
6000
0
0
0
1500
1500
1500
1500
C
GL1 Sec_1
528
528
AMPS
VOLT-
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
EF-2 (1/6 HP)
EF-2 (1/6 HP)
SERVES
1/2"
1/2"
CD.
MLO
3#10
3#10
WIRE
SURFACE
400
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
TRIP
MOUNTED
AMPS
84
82
80
78
76
74
72
70
68
66
64
62
60
58
56
54
52
50
48
46
44
CKT
3
3
3
3
3
3
3
/
NOTES
Minimum KAIC:
41
39
37
35
33
31
29
27
25
23
21
19
17
15
13
11
9
7
1
CKT
200
TRIP
208
1#6G
4#3/0
WIRE
120
2"
CD.
4
3
MULTISECTION CONN AMPS
MULTISECTION CONN V A
PANEL SECTION CONN AMPS
PANEL SECTION CONN V A
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
PANEL SL1
SERVES
WIRE
PH,
0
644
1578
AMPS
VOLT-
EXISTING
NEW
142
17069
142
17069
0
0
0
0
5044
5403
6622
A
PHASE LOAD V.A.
134
16135
134
16135
0
0
0
0
5044
5403
5688
B
FED BY
129
15491
129
15491
0
0
0
0
5044
5403
5044
C
POWER COMPANY XMFR (POLE MOUNTED)
5044
5044
5044
5403
5403
5403
5044
5044
5044
AMPS
VOLT-
AC-10 (S101)
AC-9 (S103)
AC-8 (S104)
SERVES
1"
1"
1"
CD.
MCB
1#10G
4#6
1#10G
4#6
1#10G
4#6
WIRE
SURFACE
400
45
45
45
TRIP
MOUNTED
AMPS
3
3
3
42
40
38
36
34
32
30
28
26
24
22
20
14
8
2
CKT
3
/
SERVING EXISTING TO REMAIN LOADS WHICH ARE SERVED OUT OF PANELS TO BE DEMOLISHED.
2. IN ADDITION TO THE BREAKERS SHOWN ABOVE, PROVIDE BREAKERS TO MATCH CONFIGURATION OF THE BREAKERS
1. THIS IS A SINGLE SECTION PANEL WITH NO LESS THAN 42 POLES AND NO MORE THAN 84 POLES.
NOTES
Minimum KAIC:
41
39
37
35
33
31
29
27
25
23
21
19
17
15
13
11
9
7
5
3
1
CKT
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
TRIP
208
#12
#10
WIRE
120
1/2"
1/2"
CD.
4
3
MULTISECTION CONN AMPS
MULTISECTION CONN V A
PANEL SECTION CONN AMPS
PANEL SECTION CONN V A
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
LTS-S102
LTS-S104
SERVES
WIRE
PH,
644
1378
AMPS
VOLT-
EXISTING
NEW
13
1578
13
1578
0
0
0
0
0
0
1578
A
PHASE LOAD V.A.
5
644
5
644
0
0
0
0
0
0
644
B
FED BY
3. PROVIDE A RED LOCKING DEVICE OVER BREAKER FOR CIRCUIT #2.
0
0
0
0
0
0
0
0
0
0
0
C
SMDP
LOCATION: ELECTRICAL 5
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
200
AMPS
VOLT-
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
FIRE ALARM PANEL
SERVES
1/2"
CD.
MLO
#12
WIRE
SURFACE
200
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
TRIP
MOUNTED
AMPS
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
CKT
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
/
324
38946
324
38946
3000
2872
6775
6544
6544
5403
7808
A
PHASE LOAD V.A.
323
38774
323
38774
3000
2872
6775
6544
6544
5403
7636
B
FED BY
317
38060
317
38060
3000
2872
6775
6544
6544
5403
6922
C
POWER COMPANY XMFR (POLE MOUNTED)
1500
1500
1500
1500
1500
1500
5403
5403
5403
5044
5044
5044
5044
5044
5044
5403
5403
5403
5044
5044
5044
AMPS
VOLT-
( 5 KW)
EWH-10
( 5 KW)
EWH-7
AC-15 (M110)
AC-14 (M111)
AC-13 (M116)
AC-12 (M108)
AC-11 (M101)
SERVES
1/2"
1/2"
1"
1"
1"
1"
1"
CD.
MCB
4#10
4#10
1#10G
4#6
1#10G
4#6
1#10G
4#6
1#10G
4#6
1#10G
4#6
WIRE
SURFACE
400
20
20
45
45
45
45
45
TRIP
MOUNTED
AMPS
3
3
3
3
3
3
3
38
32
26
20
14
8
2
CKT
3. IN ADDITION TO THE BREAKERS SHOWN, PROVIDE ADDITIONAL BREAKERS TO MATCH THE BREAKERS SERVING EXISTING TO REMAIN LOADS WHICH ARE SERVED OUT OF PANELS TO BE DEMOLISHED.
2. THIS IS A SINGLE SECTION PANEL WITH NO LESS THAN 42 POLES AND NO MORE THAN 84 POLES.
1. PROVIDE A RED LOCKING DEVICE OVER BREAKER FOR CIRCUIT #2.
NOTES
Minimum KAIC:
41
39
37
35
33
31
29
27
25
23
21
19
17
15
13
11
9
7
5
3
1
CKT
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
TRIP
208
#10
#10
#10
#10
#10
#10
#10
WIRE
120
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
CD.
4
3
MULTISECTION CONN AMPS
MULTISECTION CONN V A
PANEL SECTION CONN AMPS
PANEL SECTION CONN V A
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
CANOPY LTS
LTS-M102
LTS-M111
LTS-M106
SEC LTS-M102
LTS-M109
LTS-M102
SERVES
WIRE
PH,
280
1350
1232
1232
528
880
1052
AMPS
VOLT-
EXISTING
NEW
41
39
37
35
33
31
29
27
25
23
21
19
17
15
13
11
9
7
5
3
1
LOCATION: ELECTRICAL 10
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
TRIP
MOUNTED
AMPS
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
/
NOTES
Minimum KAIC:
37
33
29
25
19
13
11
9
7
1
CKT
20
20
20
20
20
20
200
TRIP
208
4#10
4#10
4#10
4#10
4#10
4#10
1#6G
4#3/0
WIRE
120
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
2"
CD.
4
3
MULTISECTION CONN AMPS
MULTISECTION CONN V A
PANEL SECTION CONN AMPS
PANEL SECTION CONN V A
( 5 KW)
EWH-11
PTAC-3
PTAC-2
PTAC-1
( 5 KW)
EWH-9
( 5 KW)
EWH-8
SPACE
SPACE
SPACE
PANEL CL1
SERVES
WIRE
PH,
1500
1500
1500
1372
1372
1372
1372
1372
1372
1500
1500
1500
1500
1500
1500
1878
2592
2764
AMPS
VOLT-
EXISTING
NEW
3
2
2
2
3
3
3
/
480
200
AMPS
VOLT-
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
EF-3
FIRE ALARM PANEL
SERVES
1/2"
1/2"
CD.
MLO
3#12
#12
WIRE
SURFACE
200
E701
ELECTRICAL
SCHEDULES -
PANEL
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
MPK
WSH
14640GILEAD
1-29-16
TO REMAIN
EXISTING KITCHEN
TO REMAIN
EXISTING GYMNASIUM
CONSTRUCTION
PHASE II
ROOM
MEETING
G1
ROOM
MULTI-PURPOSE
G2
KITCHEN
G4
GYMNASIUM
G5
SUPPLY
G6
SUPPLY
G7
MENS
G8
ROOM
LOCKER
G109
CORRIDOR
G10
JAN
G12
ROOM
HOME TEAM
G11
ROOM
SUPPLY
G13
CLOSET
G14
TEAM ROOM
VISITOR’S
G16
CORRIDOR
G15
WOMEN’S
G17
ROOM
LOCKER
G18
CORRIDOR
G19
CLASSROOM
G22
CLASSROOM
G23
CLASSROOM
G24
CLASSROOM
G25
CLASSROOM
G26
UTILITY
G27
PANTRY
G3
CLASSROOM
G21
CLASSROOM
G20
1SCALE:
1= 1’-0
88 0 4 8 16
NGYMNASIUM - DEMOLITION - HVAC
HVAC
DEMOLITION -
GYMNASIUM -
MD101
LINE LEGEND
EXISTING TO REMAIN
DEMOLITION
EXHAUST FAN
REMOVE EXISTING
EXHAUST FAN
REMOVE EXISTING
REFER TO SHEET 1/M201.
NEW WALL HUNG HEAT PUMPS.
EXISTING WALL OPENINGS FOR
HEAT PUMP (TYPICAL). LEAVE
REMOVE EXISTING WALL HUNG
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
MPK
WSH
14640GILEAD
1-29-16
CLASSROOM
8
CLASSROOM
9
ELECT
10
UTILITY
11
JAN
12
OFFICE
13
OFFICE
14
WORKROOM
15
CLASSROOM
16
CLASSROOM
17
CORRIDOR
18
CLASSROOM
19
CLASSROOM
20
CLASSROOM
21
BOYS
22
GIRLS
23
GIRLS
24
BOYS
25
CLASSROOM
26
WH
CLASSROOM
1
CLOSET
2
LAB
SCIENCE
3
CLASSROOM
4
ELECT
5
WOMENS
6
MENS
7
2SCALE:
1= 1’-0
88 0 4 8 16
N1
SCALE:1
= 1’-08
8 0 4 8 16
N
MD102
STEM BUILDING - DEMOLITION - HVAC MIDDLE SCHOOL - DEMOLITION - HVAC
HVAC
DEMOLITION -
BUILDINGS -
SCHOOL
LINE LEGEND
EXISTING TO REMAIN
DEMOLITION
PTAC UNIT (TYPICAL)
REMOVE EXISTING
ELECTRIC WALL HEATER
REMOVE EXISTING
EXHAUST FAN
REMOVE EXISTING
EXHAUST FAN
REMOVE EXISTING
FOR LOCATION OF NEW EQUIPMENT
FOR FINISHES. REFER TO 2/M202
REFER TO ARCHITECTURAL PLANS
WHERE PTAC’S WERE REMOVED
PATCH WALLS IN AREAS
PTAC UNIT (TYPICAL).
REMOVE EXISTING
TO SHEET 2/M202.
FOR NEW WORK. REFER
OPENINGS TO REMAIN
PTAC UNITS (TYPICAL).
REMOVE EXISTING
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
MPK
WSH
14640GILEAD
1-29-16
M001
A COMPRESSED AIR
AAV AUTOMATIC AIR VENT
AF AIR FOIL
-AFF ABOVE FINISHED FLOOR
AV ACID VENT
AVD AUTOMATIC VOLUME DAMPER
AW ACID WASTE
-AC ABOVE CEILING
AH- AIR HANDLING UNIT
BBD BOILER BLOW DOWN
BE BOTTOM ELEVATION
BOL BOTTOM OF LINE (UNINSULATED)
BOD BOTTOM OF DUCT
BP- BOOSTER PUMP
BTUH BRITISH THERMAL UNIT PER HOUR
-BF BELOW FLOOR
BFP BACK FLOW PREVENTOR
C CONDUIT
CC COOLING COIL
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CR CONDENSER WATER RETURN
CS CONDENSER WATER SUPPLY
CW DOMESTIC COLD WATER
CAB CABINET FAN
CF CENTRIFICAL FAN
CFM CUBIC FEET PER MINUTE
CFP CHEMICAL FEED PUMP
CFT CHEMICAL FEED TANK
CH CABINET HEATER
CHR CHILLER
CL CENTER LINE
CO CLEANOUT
CP CHILLER PUMP
CPHB CHROME PLATED HOSE BIBB
CT COOLING TOWER
CU COPPER
CV- CONVECTOR
Cv VALVE COEFFICIENT
D DRAIN
DDC DIRECT DIGITAL CONTROL
DHW DOMESTIC HOT WATER
DN DOWN
DP DIFFERENTIAL PRESSURE
DS DOWN SPOUT
DSO DOWN SPOUT OVER FLOW
DX DIRECT EXCHANGE
EAD EXHAUST AIR DAMPER
EAT ENTERING AIR TEMPERATURE
EDB ENTERING DRY BULB
EWB ENTERING WET BULB
ESP END SUCTION PUMP
ESP EXTERNAL STATIC PRESSURE
ELL ELBOW
ET EXPANSION TANK
EQT EQUIPMENT TRAP SET
EWT ENTERING WATER TEMPERATURE
EX EXPANSION TANK LINE
EXT EXTERNAL
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
F&BP FACE & BYPASS
FC FAN COIL UNIT
BPD BYPASS DAMPER
EAL EXHAUST AIR LOUVER
ECH ELECTRIC CABINET HEATER
ABBREVIATIONS
FD FLOOR DRAIN
FF FOULING FACTOR
FF- FLY FAN
FF FINISHED FLOOR
FF FINAL FILTER
FFM FIRE FLOW METER
FLEX FLEXIBLE
FM FIRE MAIN
FMS FLOW METER STATION
FOF FUEL OIL FLOW
FOR FUEL OIL RETURN
FOV FUEL OIL VENT
FOP FUEL OIL PUMP
FP FIRE PUMP
FP- FAN POWERED
FPM FEET PER MINUTE
FPS FEET PER SECOND
FRT FLOW RATE TRANSMITTER
FT FEET
G LOW PRESSURE GAS
GA GAUGE
GPM GALLONS PER MINUTE
GT GREASE TRAP
GTH GRAND TOTAL HEAT
H HEIGHT
HC HEATING COIL
HB HOSE BIBB
HBT HORIZONTAL BLOW THROUGH
HD HUB DRAIN
HDT HORIZONTAL DRAW THROUGH
HP HORSEPOWER/HIGH PRESSURE
HPA HIGH PRESSURE AIR
HPG HIGH PRESSURE GAS
HPS HIGH PRESSURE STEAM
HPWS HEAT PUMP WATER SUPPLY
HPWR HEAT PUMP WATER RETURN
HSC HORIZONTAL SPLIT CASE
HWG HOT WATER GENERATOR
HWR HEATING WATER RETURN
HWS HEATING WATER SUPPLY
ILC IN-LINE CENTRIFICAL
IT INTERVAL TIMER
IN INCHES
INV INVERT
JB JUNCTION BOX
L LENGTH
LR LONG RADIUS
LAT LEAVING AIR TEMPERATURE
LCP LOCAL CONTROL PANEL
LDB LEAVING DRY BULB
LN LIQUID NITROGEN
LWB LEAVING WET BULB
LWT LEAVING WATER TEMPERATURE
LPS LOW PRESSURE STEAM
MAV MANUAL AIR VENT
MVD MANUAL VOLUME DAMPER
MAX MAXIMUM
MBH ONE THOUSAND BTUH PER HOUR
MCC MOTOR CONTROL CENTER
MIN MINIMUM
MH MAN HOLE
MP SUMP (MUD) PUMP
MPS MEDIUM PRESSURE STEAM
MPR MEDIUM PRESSURE RETURN
MTS MEDIUM TEMPERATURE SUPPLY
MTR MEDIUM TEMPERATURE RETURN
MUA MAKE-UP AIR
MUW MAKE-UP WATER
MZ MULTIZONE
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
OA OUTSIDE AIR
OAD OUTSIDE AIR DAMPER
ODT OUTDOOR TEMPERATURE
PC PUMP CONDENSATE
PD PRESSURE DROP
PRV PRESSURE REDUCING VALVE
PWF PROPELLER WALL FAN
R REFRIGERANT
RA RETURN AIR
RAD RETURN AIR DAMPER
RAS RELIEF AIR SUPPLY
RP RECIRCULATING PUMP
RHG REFRIGERANT HOT GAS
RL REFRIGERANT LIQUID
RS REFRIGERANT SUCTION
RD ROOF DRAIN
RV RELIEF VALVE
SR SHORT RADIUS
OAL OUTSIDE AIR LOUVER
SAN SANITARY SEWER
SC SILL COCK
SCD SMOKE DAMPER
SD STORM DRAIN
SD SMOKE DETECTOR
SF SQUARE FEET
SDO STORM DRAIN OVERFLOW
SHC SENSIBLE HEAT CAPACITY
SP STAND PIPE
SP SUMP PUMP
SPS STATIC PRESSURE SENSOR
STA STATION
TR TEMPERED WATER RETURN
UG UNDERGROUND
VAC VACUUM PIPING
VDT VERTICAL DRAW THROUGH
VTR VENT THROUGH ROOF
WB WET BULB
O2 OXYGEN
?F DEGREES FAHRENHEIT
?C DEGREES CENTIGRADE
WM WATER METER
WL WATER LINE
WH WATER HEATER
WG WATER GAUGE
W WIDTH
W WASTE
VT VERTICAL TURBINE
VFD VARIABLE FREQUENCY DRIVE
VB VACUUM BREAKER
VAV VARIABLE AIR VOLUME
V VENT
UC UNDERCUT (DOOR - 3/4")
V- VALVE
TOS TOP OF STRUCTURE
TB THRUST BLOCK
T TEMPERED WATER
STR STRAINER
SP STATIC PRESSURE
SP SPRINKLER PIPE
SG SPECIALTY GAS
EUH ELECTRIC UNIT HEATER
RECIRCULATING
DHR DOMESTIC HOT WATER
TRANSMITTER
DPT DIFFERENTIAL PRESSURE
PER MINUTE
SCIM STANDARD CUBIC INCHES
TEMPERATURE
SST SATURATED SUCTION
(UNINSULATED)
TE TOP ELEVATION
(TOWER) PUMP
TP CONDENSER WATER
FSD FIRE/SMOKE DAMPER
EA EXHAUST AIR
MA MIXED AIR
AE ADJUSTABLE AIR EXTRACTOR
RAO RETURN AIR OPENING
AD AREA DRAIN/ACCESS DOOR
SINGLE LINE DUCT LEGEND
DUCT (SUPPLY, RETURN & EXHAUST)
SUPPLY DUCT UP
SUPPLY DUCT DOWN
RETURN OR EXHAUST DUCT UP
RETURN OR EXHAUST DUCT DOWN
DUCT RISE
DUCT DOWN
VOLUME DAMPER (MANUAL UNLESS INDICATED A.V.D.)
TRANSITION
DUCT TAKE-OFF (SEE SPEC. PERTAINING TO DEFLECTROLS)
TRANSITION (FLAT ON TOP)
TRANSITION (FLAT ON BOTTOM)
TRANSITION (TOP OR BOTTOM ONLY)
SUPPLY CEILING DIFFUSER
RETURN OR EXHAUST CEILING GRILLE
SIDEWALL SUPPLY
SIDEWALL RETURN
FLEXIBLE CONNECTION (DUCT)
RELIEF AIR SUPPLY TO TOILET
DUCT SPLIT WITH SPLITTER DAMPER
FLEX. DUCT WITH SCREW ON COLLAR, TAKE-OFF
DUCT WITH DUCT LINER
SQUARE ELBOW WITH TURNING VANES
RADIUS ELBOW (SEE SPECS. PERTAINING TO TURNING VANES)
AUTOMATIC VOLUME DAMPER
DN
R
12\10 SPLIT
OR
OR
SCD
FOB
T OR B
RAS
AVD
FD/SCD
FD
SMOKE CONTROL DAMPER
COMBINATION FIRE/SMOKE CONTROL DAMPER
FIRE DAMPER (FD)
FIRE DAMPER
SUMMER WINTER
DESIGN CONDITIONS
OUTSIDE
INSIDE
93 F / 76 F WB
72 F DB75 F DB / 55% RH
MARK REMARKS
GRILLE SCHEDULE
VOLUMEDAMPERNECK
FINISHNECK
RUNOUT
A
TITUS
B
C
TYPE
NOTES:
1 RUNOUT SIZE UNLESS OTHERWISE NOTED.
FACE
SIZE1
OFFWHITE
OFFWHITE
OFFWHITE
TYPE CFMS.P.
IN W.G.MARK
MAX. MAX.
RPM TS. TYPE
MOTOR
HPREMARKS
FAN SCHEDULE
MIN.
FAN DIA.
(IN)
NOTES:
1
DRIVE
LAYOUT BASIS:
MARK REMARKS
NOTES:
1
PACKAGED TERMINAL AIR CONDITIONER
MBH
HTG
REVERSE
CFM
TOTAL
MBH
TOTAL
Kw
ELEC HT
21 F DB
AC-15
AC-14
AC-13
AC-12
AC-1 1
AC-10
AC-9
AC-8
AC-7
AC-6
AC-5
AC-4
AC-3
AC-2
AC-1
LAYOUT BASIS: GREE
PTAC-3
PTAC-2
PTAC-1
EF-3
EF-2
EF-1
ILC
ILC
ILC
750
500
650
DIRECT
DIRECT
DIRECT
CGC
WRAG-HD
WSAR-HD
50F
33RL
300RL
12"x24"
36"x
36"x8"
N/A
N/A
N/A
NO
NO
NO
---
---
---
0.4
0.4
0.4
12"{
10"{
10"{
1 105
1365
1525
3465
3575
3995
1/6
1/6
1/6
280
280
280
7.6
7.6
7.6
6.1
6.1
6.1
1.6
1.6
1.6
AIR-TO-AIR WALL MOUNT HEAT PUMP SCHEDULE
MARK
AIRFLOW
EER
1
MBH COP
2
NOTES:
1
2
3
RATED @ 93 F DB AMBIENT ODT
RATED @ 47 F DB AMBIENT ODT
REMARKS
4
RATED @ 93 F DB/76 F WB ODT, 75 F DB/62 F WB IDT-SUMMER, 21 F DB ODT-WINTER, 72 F DB IDT
RATED @ 75 F DB AMBIENT ODT, 75 F DB/65.5 F WB IDT
REVERSE
CYCLE HEATMECHANICAL COOLING
2.5
2
2
2.5
2
2
2.5
2
2
2
2
2
2.5
2
2
1000
800
800
1000
800
800
1000
800
800
800
800
800
1000
800
800
175
140
140
175
140
140
175
140
140
140
140
140
175
140
140
TONS
NOMINAL
28.4
22.9
22.9
28.4
22.9
22.9
28.4
22.9
22.9
22.9
22.9
22.9
28.4
22.9
22.9
21.0
18.5
18.5
21.0
18.5
18.5
21.0
18.5
18.5
18.5
18.5
18.5
21.0
18.5
18.5 93/76
93/76
93/76
93/76
93/76
93/76
93/76
93/76
93/76
93/76
93/76
93/76
93/76
93/76
93/76
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
KW
HEAT
ELECTRIC
45
42
42
45
42
42
45
42
42
42
42
42
45
42
42
MCA /PHASE
VOLTAGE
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
BARD
BASIS:
LAYOUT
T30
T24
T24
T30
T24
T24
T30
T24
T24
T24
T24
T24
T30
T24
T24
CFM
NOMINAL
CFM
O.A.
GRILLE MARK
ASSOCIATED
DIFFUSER
SUPPLY
GRILLE
RETURN
MBH
TOTAL
MBH
SENS.
( F)
EAWB
EADB/
( F)
EADB
SUMMER (%)
EFFICIENCY
ENERGY RECOVERY PERFORMANCE
VENTILATION AIR
WINTER (%)
EFFICIENCY
MBH
TOTAL
SYSTEM
MBH
LATENT.
SYSTEM
CIRCUIT PERFORMANCE
HOT GAS DEHUMIDIFICATION
WATER/HR.
POUNDS OF
MARK KW REMARKS
ELECTRIC WALL HEATER SCHEDULE
TYPE/PHASE
VOLTAGE
208/3
208/3
208/3
208/3
208/3
208/3
208/3
A B
A B
A B
A B
A B
A B
A B
A B
A B
A B
A B
A B
A B
A B
A B
1 1.21 1.2
1 1.0
1 1.2
1 1.2
1 1.2
1 1.2
1 1.2
1 1.2
1 1.0
1 1.2
1 1.2
1 1.0
1 1.2
1 1.2
1 1.0
65 5323 3159 77 16004
65 5323 3159 77 16004
65 5323 3159 77 16004
65 5323 3159 77 16004
65 5323 3159 77 16004
65 5323 3159 77 16004
65 5323 3159 77 16004
65 5323 3159 77 16004
65 5323 3159 77 16004
65 5323 3159 77 16004
65 5323 3159 77 16004
65 5323 3159 77 16004
65 5323 3159 77 16004
65 5323 3159 77 16004
65 5323 3159 77 16004
2 3
WINTER (BTUH)
RECOVERED
HEAT
SUMMER (BTUH)
REJECTED
SENS. HEAT
SUMMER (BTUH)
REJECTED
TOTAL HEAT
26.4
22.2
22.2
26.4
22.2
22.2
26.4
22.2
22.2
22.2
22.2
22.2
26.4
22.2
22.2 3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
6.1
6.1
1 1.8
6.1
6.1
6.1
6.1
6.1
1 1.8
6.1
6.1
1 1.8
6.1
6.1
1 1.8
6
6
1 1
6
6
6
6
6
1 1
6
6
1 1
6
6
1 1
HVAC
SCHEDULES -
LEGENDS, &
ABBREVIATIONS,
EWH-11
EWH-10
EWH-9
EWH-8
EWH-7
EWH-6
EWH-5
EWH-4
EWH-3
EWH-2
EWH-1
CAB
CAB
CAB
CAB
CAB
CAB
CAB
CAB
CAB
CAB
CAB
5
5
5
5
5
5
5
5
5
5
5
208/3
208/3
208/3
208/3
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
MPK
WSH
14640GILEAD
1-29-16
M002
HVAC
DETAILS -
SUPPORT FROM STRUCTURE
CEILING
EXHAUST GRILLE
NOT TO SCALE
DO NOT APPLY TO FUME EXHAUST GRILLES/REGISTERS.1
0.75 R
6
MAXIMUM OFFSET
SHALL NOT EXCEED
ONE DUCT DIAMTER
EXCEED 1/2" PER FT
MAXIMUM SAG SHALL NOT
DIRECTLY ON TOP OF PLENUM.
0.75 RADIUS, METAL ELBOW
IF TOP ENTRY IS USED, PROVIDE
DUCT PRESSURE CLASS.
SEAL JOINT AS SPECIFIED FOR
MIN. TWO PER SIDE, AND
WITH SHEET METAL SCREWS,
FASTEN PLENUM TO GRILLE
SHEETMETAL SCREWS)
TO PLENUM (MINIMUM OF 4
FLANGE, SEAL AND SECURE
5 FT. OF FLEX DUCT
PROVIDE MAXIMUM
DETAIL AT TYPICAL GENERAL EXHAUST GRILLE - UNLINED
NOTES:(THIS DETAIL ONLY)
OR 12", WHICHEVER IS LARGER
THAN INDICATED RUN OUT SIZE
HEIGHT SHALL BE 2" LARGER
TAKE-OFF IS INACCESSIBLE.
ACCESSIBLE CEILING IF
AS POSSIBLE OVER
FAR AWAY FROM GRILLE
LOCATE MVD IN DUCT AS
WITH GASKETED FLANGE
45 DEGREE TAKE-OFF
ARCHITECTURAL
GRILLE
FLOOR SLAB
GROUND
COMBINATION ROOM
CABINET AND
WALL SLEEVE
AIR
FLOW
CONSOLE A.C. UNIT
(TYPICAL)
NOT TO SCALE
CONSOLE A.C. UNIT INSTALLATION (PTAC)2
(RE-MOVEABLE)
CEILING
TOILET
RELIEF AIR SUPPLY TO TOILET (RAS)
NOT TO SCALE
GRILLE
AS GRILLE
SAME SIZE
GRILLE
SPACE
ADJACENT
UP TO STRUCTURE
SHEET METAL STRAP
WALL
1
CAULK
SET IN BED OF CAULK
BRICK
BRACKET AND METAL FLASHING DETAILSCALE: 1�"=1’-0"
WALL MOUNT HEAT PUMP
WALL MOUNT HEAT PUMP MOUNTING
{63 ALUMINUM
CAP FLASHING
2 - ?" DIA. BOLTS
IN EXP. SHIELD. 6
PER ANGLE
MOUNTING BRACKET.
FURNISHED W/ UNIT.
4
7"
4"
4"CAULK
SCALE: 1�"=1’-0"
PUMP FLASHING DETAIL
WALL MOUNT HEAT
CAP FLASHING, SECURE
TO MASONRY W/ NYLON
TAP-INS W/ CAD PLATED
DRIVE PINS AT 12" O.C.
PROVIDE 1 X 2 X �"
WASHER AT EA. PIN.
WALL MOUNT
HEAT PUMP
5
SUPPLY AIR
GRILLE
RETURN AIR
GRILLE
9
8
98
1
3
4
5
NOT TO SCALE
FOR SIZES AND LOCATION.
SEE ARCHITECTURAL DETAILS FOR ADDITIONAL
INSTALLATION REQUIREMENTS.
CONDENSATE DRAIN. PIPE TO WITHIN 6" OF GRADE.
PROVIDE AIR TIGHT SEALS.
1
2
3
4
5
6
7
8
9
WALL MOUNTHEAT PUMP
7
7
FIN. FLOOR
6
REFER TO ARCHITECTURAL FOR MOUNTING HEIGHT.
REFER TO DETAIL FOR MOUNTING BRACKET.
REFER TO DETAIL FOR FLASHING DETAIL.
WALL MOUNT HEAT PUMP. REFER TO PLANS
WALL MOUNT
HEAT PUMP
GRILLE. SEE PLANS FOR DESIGNATION. PROVIDE TRANSISITION
FROM UNIT CONNECTION SIZE TO GRILLE SIZE
5
M002
4
M002
SHEET METAL DUCT SAME SIZE AS UNIT OPENING. (INSULATE)
PROVIDE TRANSITION TO GRILLE SIZE.
2
3
NOTES:(THIS DETAIL ONLY)
LOUVER
WALL MOUNTED LOUVER WITH PLENUM
COUNTER
FLASHING
20 GAUGE SLEEVE
16"MIN.
REFER TO ARCHITECTURAL
FOR STRUCTURE MATERIALS
SUB FRAME
IN BLOCK WALLS,
USE LINTELBLOCK
ON HEAD AND SILL
PROVIDE MINIMUM 16 INCH
PLENUM BEHIND LOUVER
NOT TO SCALE 7
A
B
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
MPK
WSH
14640GILEAD
1-29-16
KITCHEN
G106
GYMNASIUM
G107
CORRIDOR
G110MEN’S
G111
ROOM
LOCKER
G112
ROOM
HOME TEAM
G113
JAN
G114
SUPPLY
G115
CLOSET
G116
TEAM ROOM
VISITING
G117
CORRIDOR
G118WOMEN’S
G119
ROOM
LOCKER
G120
CORRIDOR
G121
YOGA ROOM
G124
CLASSROOM
G125
CLASSROOM
G126
UTILITY
G127
TRAINING
WEIGHT
G123
EXISTING RAMPEXERCISE
AEROBIC
G122
WORK AT THIS AREA
NO SCOPE OF
IN THIS AREA
NO SCOPE OF WORK
DECK TO REMAIN
EXISTING CONC.
CONSTRUCTION
PHASE II
1SCALE:
1= 1’-0
88 0 4 8 16
NM201
HVAC
NEW WORK -
GYMNASIUM -
GYMNASIUM - NEW WORK - HVAC
LINE LEGEND
POINT OF CONNECTION
EXISTING TO REMAIN
NEW WORK
BA
EWH-1
AC-1
T T
T
T
T
T
T
T
AC-2
B
A
AC-3
B
A
AC-4
B
A
AC-5
B
A
AC-6
B
A
AC-7
B
A
EWH-2
EF-2RAS
C
C
C
CRAS
8"{
6"{
10"{
C
| 75
C
|125
C
|300
8"{
12"{
MVD
MVD
12"{
EF-2 RASC
C
CC
RAS
8"{
6"{
10"{C
| 75
C
|125
C
|300
8"{
12"{
MVD
MVD
12"{
EWH-3
EWH- 4
18" DEEP PLENUM
LOUVER w/FULLSIZE
16"x24" EXHAUST
18" DEEP PLENUM
LOUVER w/FULLSIZE
16"x24" EXHAUST
EWH-6
EWH-5
PANELING ABOVE WALKWAY AWNING
LOCATE LOUVER IN METAL
PANELING ABOVE WALKWAY AWNING
LOCATE LOUVER IN METAL
FOR NEW UNITS (TYP)
OPENINGS AS REQUIRED
UNITS. MODIFY EXISTING
FOR NEW WALL HUNG
WALL PENETRATIONS
RE-USE EXISTING
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
MPK
WSH
14640GILEAD
1-29-16
CLASSROOM
M101
ELEC
M102
UTILITY
M103
JAN
M104
CORRIDOR
M105
WORKROOM
M106
ROOM
RESOURCE
M107CLASSROOM
M108
CORRIDOR
M109
CLASSROOM
M110
CLASSROOM
M111
BOYS
M112
GIRLS
M113
CLASSROOM
M116
RESTROOM
H/C
M114
CLOSET
M115
DROP-OFF TO REMAIN
COVERED
CLASSROOM
S101
CLOSET
S102
LAB
SCIENCE
S103
CLASSROOM
S104
MENS
S105
WOMENS
S106ELECT
S107
WH
2SCALE:
1= 1’-0
88 0 4 8 16
N1
SCALE:1
= 1’-08
8 0 4 8 16
N
M202
STEM BUILDING - NEW WORK - HVAC MIDDLE SCHOOL - NEW WORK - HVAC
HVAC
NEW WORK -
BUILDINGS -
SCHOOL
LINE LEGEND
POINT OF CONNECTION
EXISTING TO REMAIN
NEW WORK
AC-8
B
T
T
T
B
AC-9
B
AC-10
B
AC-1 1
T T
TT
T
EWH-7
A
AC-13
A
A
AC-14
A
AC-15
AC-12
EF-3
EWH-8
C
| 75
|300
C C
|375
EWH-9
A B
BBB
A
A
A
12"{
12"{
10"{
10"{
8"{
MVD MVD
PTAC-1 PTAC-2 PTAC-3
EWH-10
EWH-11
(TYP)
FOR NEW PTAC UNITS
WALL PENETRATION
RE-USE EXISTING
18" DEEP PLENUM
LOUVER w/FULLSIZE
16"x24" EXHAUST
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JDL
WHD
14640GILEAD
1-29-16
TO REMAIN
EXISTING KITCHEN
TO REMAIN
EXISTING GYMNASIUM
CONSTRUCTION
PHASE II
ROOM
MEETING
G1
ROOM
MULTI-PURPOSE
G2
KITCHEN
G4
GYMNASIUM
G5
SUPPLY
G6
SUPPLY
G7
MENS
G8
ROOM
LOCKER
G109
CORRIDOR
G10
JAN
G12
ROOM
HOME TEAM
G11
ROOM
SUPPLY
G13
CLOSET
G14
TEAM ROOM
VISITOR’S
G16
CORRIDOR
G15
WOMEN’S
G17
ROOM
LOCKER
G18
CORRIDOR
G19
CLASSROOM
G22
CLASSROOM
G23
CLASSROOM
G24
CLASSROOM
G25
CLASSROOM
G26
UTILITY
G27
PANTRY
G3
CLASSROOM
G21
CLASSROOM
G20
1SCALE:
1= 1’-0
88 0 4 8 16
NPD101GYMNASIUM - DEMOLITION - PLUMBING
PLUMBING
DEMOLITION -
GYMNASIUM -1
1
2
2 2 2 2
222
222
2
NOTES:(THIS SHEET ONLY)
1
NON-SHRINK GROUT AND ABANDON IN PLACE.
DRAINS TO BELOW FLOOR. COP PIPING AND FILL WITH
TO NEW FIXTURES IN NEW WORK PHASE. REMOVE FLOOR
CAP WATER AND VENT PIPING ABOVE CEILING FOR EXTENSION
REMOVE EXISTING SHOWERS AND ALL ASSOCIATED PIPING.
EXISTING FIXTURES ARE TO REMAIN.2
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JDL
WHD
14640GILEAD
1-29-16
CLASSROOM
8
CLASSROOM
9
ELECT
10
UTILITY
11
JAN
12
OFFICE
13
OFFICE
14
WORKROOM
15
CLASSROOM
16
CLASSROOM
17
CORRIDOR
18
CLASSROOM
19
CLASSROOM
20
CLASSROOM
21
BOYS
22
GIRLS
23
GIRLS
24
BOYS
25
CLASSROOM
26
WH
CLASSROOM
1
CLOSET
2
LAB
SCIENCE
3
CLASSROOM
4
ELECT
5
WOMENS
6
MENS
7
2SCALE:
1= 1’-0
88 0 4 8 16
N1
SCALE:1
= 1’-08
8 0 4 8 16
N
PD102
STEM BUILDING - DEMOLITION - PLUMBING MIDDLE SCHOOL - DEMOLITION - PLUMBING
PLUMBING
DEMOLITION -
BUILDINGS -
SCHOOL
NOTES:(THIS SHEET ONLY)
1
EXISTING FIXTURES ARE TO REMAIN.2
1
1
1
1
NON-SHRINK GROUT AND ABANDON IN PLACE.
PIPING TO BELOW FLOOR. CAP PIPING AND FILL WITH
TO NEW FIXTURES IN NEW WORK PHASE. REMOVE SANITARY
CAP WATER AND VENT PIPING ABOVE CEILING FOR EXTENSION
REMOVE EXISTING FIXTURES AND ALL ASSOCIATED PIPING.
1
1
1
1
2
2
2
2
2
2
2
2
2
2
3
3 EXISTING WATER HEATER IS TO REMAIN.
2
22
2
1
1 1
1
2
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JDL
WHD
14640GILEAD
1-29-16
P001
PLUMBING
DETAILS -
NOTES &
SCHEDULE,
LEGEND,
FIXTURES.
SEE ARCHITECTURAL PLANS FOR EXACT LOCATION OF ALL PLUMBING
ALL WATER PIPING SHALL BE RUN ABOVE CEILING UNLESS OTHERWISE
NOTED.
ALL VENTS THRU ROOF (VTR) SHALL BE OFFSET A MINIMUM OF 15’-0"
FROM ALL OUTSIDE INTAKES.
-
-
-
-
1
2
3
4
-5 PROVIDE HANGER ON ALL HORIZONTAL WATER PIPING INSIDE CHASES
COORDINATE PLUMBING PIPING WITH AIR CONDITIONING DUCTS, EQUIPMENT
AND ELECTRICAL CONDUIT.
GENERAL NOTES:
WITHIN 6" OF SPECIFIED WATER HAMMER ARRESTOR.
NOTE TO CONTRACTOR:
PROVIDE ACCESS TO THE CONCEALED UTILITY.
WORK OR CONNECTION, WITH THE EXCEPTION OF EXCAVATION OR OTHER WORK TO
PRIOR TO PURCHASING ANY MATERIALS OR PERFORMING ANY WORK, EXTENSION OF
TO CODE AND AS SHOWN. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES
NEW PIPES BEING ROUTED TO EXISTING UTILITIES CAN BE INSTALLED CONFORMING
FLUID BEING HANDLED AND INVERTS OF ALL EXISTING UTILITIES AND CONFIRM THAT
WHERE CONNECTING TO A UTILITY OR SERVICE, VERIFY LOCATION, SIZES, MATERIALS,
FIXTURES OR PERFORMING ANY WORK.
DEVIATIONS OR INCONSISTENCIES PRIOR TO PURCHASING OF ANY MATERIALS OR
OF ANY DEVIATIONS NOTED. THIS REVIEW IS INTENDED TO CONFIRM ANY
SCALE PLANS AND ELEVATIONS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT
SCHEDULE, PLUMBING FIXTURE SPECIFICATIONS, ARCHITECTURAL SMALL AND LARGE
THE PLUMBING SMALL AND LARGE SCALE PLANS, PLUMBING RISERS, PLUMBING
AS PART OF CONSTRUCTION QUALITY CONTROL, THE CONTRACTOR SHALL REVIEW
NOTE TO CONTRACTOR:
WATER HAMMER ARRESTOR SCHEDULE
REMARKS
MARKRATING
FIXTURE UNIT
SIZE
CONNECTION
PDI-A
PDI-B
1 -11 FIXTURE UNITS
12 -32 FIXTURE UNITS
�"
1"
MANUFACTURER’S RECOMMENDATIONS
SIZE & INSTALL PER
MANUFACTURER’S RECOMMENDATIONS
SIZE & INSTALL PER
LEGEND
SOIL , WASTE VENT
D CONDENSATE DRAIN COLD WATER
HOT WATER (120 ) HOT WATER RETURN
G GAS (LOW PRESSURE) HIGH PRESSURE GAS HPG
GATE VALVEBALL VALVE
CHECK VALVEBALANCER (CIRCUIT SETTER)
FLOW INDICATOR
GLOBE VALVE UNION
GAS COCK AQUASTAT
NON-FREEZE WALL HYDRANTNFWH HOSE BIBB (HB)
T THERMOMETERTEST (PETE’S) PLUG
INCREASER FLOOR DRAIN (FD)
CLEANOUT (CO) CLEANOUT (CO)
HUB DRAIN BELOW FLOORBF
ABOVE CEILINGAC ABOVE FINISHED FLOORAFF
VENT THRU ROOF ABOVE FINISHED GRADEAFGVTR
NOT TO SCALENTSHOSE BIBB
CHROME PLATEDCPHB
WATER TO REMAIN
EXISTING HOT
RETURN TO REMAIN
EXISTING HOT WATER
EXISTING VENT TO REMAINTO REMAIN
EXISTING SOIL, WASTE
WATER TO REMAIN
EXISTING COLD
BE REMOVED
EXISTING PIPING TO
LIMIT OF DEMOLITIONNEW TO EXISTING
POINT OF CONNECTION
FIXTURE SCHEDULE
FIXTURESFLOOR
TO RIM
WASTESUPPLY
HOT COLD
FIX. CONN.
HOT COLDREMARKS
I.D.
FIXT.
WATER CLOSET 17" 4" 1" ADA --- 1" ---WC1
34" ADA LAVATORY 1�" �" �" �" �" LV1
NOT TO SCALE1
"CLOSED POSITION"
MEMBRANE IN
TRAP GUARD
DRAIN PIPE
FINISHED FLOOR
HUB DRAIN
"OPEN POSITION"
MEMBRANE IN
TRAP GUARD
(SEWER GAS EMISSIONS PROTECTOR)
FLOOR DRAIN (SEE SPECIFICATIONS)
HUB/ FLOOR DRAIN ’TRAP SEALER ASSEMBLY’
FLUSH VALVE
PIPE RING SUPPORT
BRACKET; SECURE TO
WALL WITH TOGGLE
BOLTS
STEEL STUD WALL
FRAMING WITH �"
GYP. BOARD
�" X 6" COPPER PIPE
FLATTENED AND SOLDERED
TO WATER PIPE FASTENED
TO STEEL STUD
SUPPLY
C.W.CHASE SPACE
FLUSH VALVE HANDLE
A.D.A. APPROVED
FLUSH VALVE ANCHOR
NOT TO SCALE 4
WC1
CONCEALED ARM
CARRIER
WALL
FINISHED FLOOR
VARIES
(SEE FIXTURE SCHEDULE)
(WITH CONCEALED ARM CARRIER)
MOUNTING BRACKET ASSEMBLY
(USE WHEN NO CARRIER IS USED)
REFER TO SPECIFICATION
FOR FAUCET TYPE
P-TRAP
ESCUTCHEON PLATE
OFFSET GRID DRAIN
HANDICAPPED LAVS ONLY
LAVATORY MOUNTING &
P-TRAP LOCATION DETAIL
NOT TO SCALE 3
AREA
CHASE
FINISH FLOOR
INSIDE CAULK
CONNECTIONCLEANOUT PLUG
LOCKING SCREW
FINISH FLOOR CLEANOUT
SCORIATED COVER
SECURED RIM &TAB COVER & SET SCREW
STAINLESS STEEL CARPET
CARPET FLOORSCONCRETE FLOORS
VINYL, TILE OR
NOT TO SCALE 5
2�" MIN.
FINISHED FLOOR
WA
LL
11�
"
FOR FLOOR TO RIM
HEIGHT REFER TO
FIXTURE SCHEDULE.
FLUSH VALVE
TAILPIECE SUPPORT
FLUSH VALVE HANDLE
FLUSH VALVE SUPPORT
NOT TO SCALE 2
WC1
(1 REQ’D AT 11�") �" 40"ELEC. WATER COOLER 1�" �" --- ---EWC1
ADA LAVATORY C.T. 1�" �" �" �" �" LV2
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JDL
WHD
14640GILEAD
1-29-16
KITCHEN
G106
GYMNASIUM
G107
CORRIDOR
G110MEN’S
G111
ROOM
LOCKER
G112
ROOM
HOME TEAM
G113
JAN
G114
SUPPLY
G115
CLOSET
G116
TEAM ROOM
VISITING
G117
CORRIDOR
G118WOMEN’S
G119
ROOM
LOCKER
G120
CORRIDOR
G121
YOGA ROOM
G124
CLASSROOM
G125
CLASSROOM
G126
UTILITY
G127
TRAINING
WEIGHT
G123
EXISTING RAMPEXERCISE
AEROBIC
G122
WORK AT THIS AREA
NO SCOPE OF
IN THIS AREA
NO SCOPE OF WORK
DECK TO REMAIN
EXISTING CONC.
CONSTRUCTION
PHASE II
1SCALE:
1= 1’-0
88 0 4 8 16
NP201GYMNASIUM - NEW WORK - PLUMBING
PLUMBING
NEW WORK -
GYMNASIUM -
1
P301
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JDL
WHD
14640GILEAD
1-29-16
CLASSROOM
M101
ELEC
M102
UTILITY
M103
JAN
M104
CORRIDOR
M105
WORKROOM
M106
ROOM
RESOURCE
M107CLASSROOM
M108
CORRIDOR
M109
CLASSROOM
M110
CLASSROOM
M111
BOYS
M112
GIRLS
M113
CLASSROOM
M116
RESTROOM
H/C
M114
CLOSET
M115
DROP-OFF TO REMAIN
COVERED
CLASSROOM
S101
CLOSET
S102
LAB
SCIENCE
S103
CLASSROOM
S104
MENS
S105
WOMENS
S106ELECT
S107
WH
2SCALE:
1= 1’-0
88 0 4 8 16
N1
SCALE:1
= 1’-08
8 0 4 8 16
N
P202
STEM BUILDING - NEW WORK - PLUMBING MIDDLE SCHOOL - NEW WORK - PLUMBING
PLUMBING
NEW WORK -
BUILDINGS -
SCHOOL
WC1
LV1
IS TO REMAIN.
EXISTING WATER HEATER
EWC1
EWC13
3
1
2
NOTES:(THIS SHEET ONLY)
1
2
3
CEILING. CONNECT TO EXISTING COLD WATER PIPING IN CHASE.
FLOOR. ROUTE VENT PIPE UP TO EXISTING PIPING ABOVE THE
CONNECT NEW LAVATORY TO EXISTING SANITARY MAIN BELOW
CEILING. CONNECT TO EXISTING COLD WATER PIPING IN CHASE.
FLOOR. ROUTE VENT PIPE UP TO EXISTING PIPING ABOVE THE
CONNECT NEW WATER CLOSET TO EXISTING SANITARY MAIN BELOW
WAS REMOVED.
STUB-OUTS FROM WHEN EXISTING ELECTRIC WATER COOLER
CONNECT NEW ELECTRIC WATER COOLER TO EXISTING PIPE
THESE SPACES.
ARE TO REMAIN IN
EXISTING FIXTURES
IS TO REMAIN.
EXISTING FIXTURE
BOWL.
PROVIDE NEW LAVATORY
THESE SPACES, EXCEPT
ARE TO REMAIN IN
EXISTING FIXTURES
LV2
LV2LV2
LV2
THIS SPACE.
ARE TO REMAIN IN
EXISTING FIXTURES
PROJECT #
DATE
DRAWN BY
CHECKED BY
SCALE AS SHOWN
PERMISSION OF THE ARCHITECT.
WITHOUT THE EXPRESS WRITTEN
MECHANICALLY, FOR ANY PURPOSE,
FORM, ELECTRONICALLY OR
REPRODUCED OR TRANSMITTED IN ANY
PART OF THIS DOCUMENT SHALL BE
PROPERTY OF THE ARCHITECT. NO
SERVICE AND SHALL REMAIN THE
THIS DRAWING IS AN INSTRUMENT OF
' 2011 SIZ
EM
OR
E G
RO
UP
ww
w.size
more
gro
up.c
om
F: 404 6
05 0
890
T: 404 6
05 0
690
ATL
AN
TA,
GE
OR
GIA 3
0318
1700 C
OM
ME
RC
E D
RIV
E,
NW
MA
CO
N,
GE
OR
GIA 3
1206
1931 R
OC
KY C
RE
EK R
OA
D
RE
NO
VA
TIO
N
GIL
EA
D-B
LO
OM
FIE
LD C
OM
PLE
X
MA
CO
N-BIB
B C
OU
NT
YNo.
DES
CRIP
TIO
ND
ATE
JDL
WHD
14640GILEAD
1-29-16
CORRIDOR
G110MEN’S
G111
ROOM
LOCKER
G112
ROOM
HOME TEAM
G113
JAN
G114
SUPPLY
G115
CLOSET
G116
TEAM ROOM
VISITING
G117
CORRIDOR
G118WOMEN’S
G119
ROOM
LOCKER
G120
P301
1
NSCALE:
1
4= 1’-0
4 0 2 4 8
LARGE SCALE - GYMNASIUM - NEW WORK - PLUMBING
WC1
LV1
ARE TO REMAIN.
IN THIS SPACE
EXISTING FIXTURES 1�"-AC
2"W&V
�"
3"-BF
1
3
4
2
1�"-AC
2
2"
NOTES:(THIS SHEET ONLY)
1
2
3
4
TO SUPPLY THE LAVATORY.
PIPES ABOVE CEILING FROM SHOWER. ROUTE DOWN IN CHASE
CONNECT NEW �" HOT AND COLD WATER PIPING TO EXISTING
DOWN IN CHASE TO SERVE WATER CLOSET.
CEILING IN THIS LOCATION. ROUTE PIPE TO CHASE AND DROP
CONNECT NEW 1�" COLD WATER TO EXISTING MAINS ABOVE THE
PERFORMING ANY WORK.
EXISTING WASTE PIPING AND VERIFY LOCATION PRIOR TO
THAT SERVED THE SHOWERS. CONTRACTOR TO CAMERA
CONNECT NEW 3" WASTE TO EXISTING MAIN BELOW FLOOR
THE CEILING.
CONNECT NEW 2" VENT PIPE TO EXISTING MAIN ABOVE
PLUMBING
NEW WORK -
GYMNASIUM -
LARGE SCALE
ARE TO REMAIN.
IN THIS SPACE
EXISTING FIXTURES
WC1
LV1
2"W&V
�"
3"-BF
1
3
4
2"
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
HJ
BCR
1/29/2016
14640GILEAD
THIS DRAWING IS AN INSTRUMENT OF
SERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NO
PART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,
WITHOUT THE EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT.
1700 C
OM
ME
RC
E D
RIV
E, N
W
AT
LA
NT
A, G
EO
RG
IA
30318
T: 404 605 0690
F: 404 605 0890
ww
w.sizem
oregroup.com
© 2011 SIZEMORE GROUP
GILE
AD
-B
LO
OM
FIE
LD
C
OM
PLE
X
RE
NO
VA
TIO
N
19
31
R
OC
KY
C
RE
EK
R
OA
D
MA
CO
N, G
EO
RG
IA
3
12
06
MA
CO
N-B
IB
B C
O.
RE
LE
AS
ED
F
OR
C
ON
ST
RU
CT
IO
N
No
.D
ES
CR
IP
TIO
ND
AT
E
AS SHOWN
Foresite Group, Inc.5185 Peachtree PkwySuite 240Norcross, GA 30092
o | 770.368.1399f | 770.368.1944
w | www.fg-inc.net
01
/2
9/2
01
6
S001
STRUCTURAL
GENERAL
NOTES
GENERAL
1. NO PROVISION OF ANY REFERENCED STANDARD SPECIFICATION, MANUAL OR CODE (WHETHER OR NOT
SPECIFICALLY INCORPORATED BY REFERENCE IN THE CONTRACT DOCUMENTS) SHALL BE EFFECTIVE TO CHANGE
THE DUTIES AND RESPONSIBILITIES OF OWNER, CONTRACTOR, DESIGN PROFESSIONAL, SUPPLIER, OR ANY OF
THEIR CONSULTANTS, AGENTS, OR EMPLOYEES FROM THOSE SET FORTH IN THE CONTRACT DOCUMENTS. NOR
SHALL IT BE EFFECTIVE TO ASSIGN TO THE DESIGN PROFESSIONAL OF RECORD OR ANY OF THE DESIGN
PROFESSIONAL OF RECORD'S CONSULTANTS, AGENTS, OR EMPLOYEES ANY DUTY OR AUTHORITY TO SUPERVISE
OR DIRECT THE FURNISHING OR PERFORMANCE OF THE WORK OR ANY DUTY OR AUTHORITY TO UNDERTAKE
RESPONSIBILITIES CONTRARY TO THE PROVISIONS OF THE CONTRACT DOCUMENTS.
2. CONTRACT DOCUMENTS INCLUDE, BUT ARE NOT LIMITED TO, THE STRUCTURAL DOCUMENTS (DRAWINGS AND
SPECIFICATIONS), BUT DO NOT INCLUDE SHOP DRAWINGS, VENDOR DRAWINGS, OR MATERIAL PREPARED AND
SUBMITTED BY THE CONTRACTOR.
3. REFERENCE TO STANDARD SPECIFICATIONS OF ANY TECHNICAL SOCIETY, ORGANIZATION, OR ASSOCIATION OR
TO CODES OF LOCAL OR STATE AUTHORITIES, SHALL MEAN THE LATEST STANDARD, CODE, SPECIFICATION OR
TENTATIVE SPECIFICATION ADOPTED AT THE DATE OF TAKING BIDS, UNLESS SPECIFICALLY STATED OTHERWISE.
4. CONTRACT DOCUMENTS SHALL GOVERN IN THE EVENT OF A CONFLICT WITH THE CODE OF PRACTICE OR
SPECIFICATIONS OF ACI, PCI, AISC, SJI OR OTHER STANDARDS. WHERE A CONFLICT OCCURS WITHIN THE
CONTRACT DOCUMENTS, THE STRICTEST REQUIREMENT SHALL GOVERN.
5. MATERIAL, WORKMANSHIP, AND DESIGN SHALL CONFORM TO THE REFERENCED BUILDING CODE.
6. CONTRACTOR SHALL COORDINATE THE STRUCTURAL DOCUMENTS WITH THE ARCHITECTURAL DOCUMENTS.
DESIGN PROFESSIONAL SHALL BE NOTIFIED OF ANY DISCREPANCY OR OMISSION. FOR DIMENSIONS NOT SHOWN
ON THE STRUCTURAL DRAWINGS SEE THE ARCHITECTURAL DRAWINGS.
7. CONTRACTOR SHALL VERIFY EXISTING DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS BEFORE STARTING
WORK. DESIGN PROFESSIONAL SHALL BE NOTIFIED OF ANY DISCREPANCY.
8. CONTRACTOR HAS SOLE RESPONSIBILITY FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES
OF CONSTRUCTION.
9. THE STRUCTURE IS STABLE ONLY IN ITS COMPLETED FORM. TEMPORARY SUPPORTS REQUIRED FOR STABILITY
DURING ALL INTERMEDIATE STAGES OF CONSTRUCTION SHALL BE DESIGNED, FURNISHED, AND INSTALLED BY THE
CONTRACTOR.
10. CONTRACTOR HAS SOLE RESPONSIBILITY TO COMPLY WITH ALL OSHA REGULATIONS.
11. ELECTRONIC DRAWING FILES WILL NOT BE PROVIDED TO THE CONTRACTOR. REPRODUCTION OF STRUCTURAL
DRAWINGS FOR SHOP DRAWINGS IS NOT PERMITTED.
12. REVIEW OF SUBMITTALS OR SHOP DRAWINGS BY THE DESIGN PROFESSIONAL DOES NOT RELIEVE THE
CONTRACTOR OF THE SOLE RESPONSIBILITY TO REVIEW AND CHECK ALL SUBMITTALS AND SHOP DRAWINGS
BEFORE SUBMITTING TO THE DESIGN PROFESSIONAL. CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR
ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY PERTAIN TO
MEMBER SIZES, DETAILS, AND DIMENSIONS SPECIFIED IN THE CONTRACT DOCUMENTS.
13. DETAILS LABELED "TYPICAL" ON THE STRUCTURAL DRAWINGS APPLY TO ALL SITUATIONS OCCURRING ON THE
PROJECT THAT ARE THE SAME OR SIMILAR TO THE TYPICAL DETAILS UNLESS THOSE LOCATIONS ARE
SPECIFICALLY DETAILED OTHERWISE.
14. STRUCTURAL DESIGN PROFESSIONAL IS NOT RESPONSIBLE FOR THE DESIGN OF COLD-FORMED METAL FRAMING,
OR OTHER SYSTEMS NOT SHOWN IN THE STRUCTURAL DOCUMENTS. SUCH SYSTEMS SHALL BE DESIGNED,
FURNISHED, AND INSTALLED AS REQUIRED BY OTHER PORTIONS OF THE CONTRACT DOCUMENTS.
CODE/DESIGN CRITERIA
1. STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE FOLLOWING:
INTERNATIONAL BUILDING CODE, 2012 EDITION WITH GEORGIA AMMENDMENTS.
2. GRAVITY LOADS
2.1 UNIFORM ROOF LIVE LOADS (REDUCED AS ALLOWED BY THE BUILDING CODE):
ROOF 20 PSF
GROUND SNOW LOAD, Pg 5 PSF
PONDING AND DRIFT EFFECTS HAVE BEEN INCLUDED IN THE DESIGN.
2.2 DEAD LOADS (IN ADDITION TO STRUCTURE SELF-WEIGHT):
ROOF:
ROOFING 5 PSF
INSULATION 5 PSF
MISCELLANEOUS 3 PSF
3. WIND LOADS:
ULTIMATE DESIGN WIND SPEED, VULT = 115
NOMINAL DESIGN WIND SPEED, VASD = 90
RISK CATEGORY: II
EXPOSURE B
INTERNAL PRESSURE COEFFICIENT = ±0.18
SEE COMPONENT AND CLADDING DESIGN WIND PRESSURE DIAGRAM.
4. UNLESS NOTED OTHERWISE CALCULATED INDIVIDUAL MEMBER DEFLECTIONS (IN INCHES) DO NOT EXCEED THE
FOLLOWING:
DEAD LOAD LIVE LOAD DEAD + LIVE LOAD
ROOF MEMBERS: L/240 L/360 L/240
WHERE, L = SPAN LENGTH (IN INCHES) BETWEEN SUPPORTS. (FOR CANTILEVERS, L IS TWICE THE LENGTH
OF THE CANTILEVER.) NOTE THAT THE TOTAL MAXIMUM CALCULATED FLOOR SYSTEM DEFECTION WILL BE
THE SUM OF THE DEFLECTIONS OF THE SUPPORTED ELEMENTS IN A BAY.
METAL DECK
1. DECK DESIGN IS BASED ON THE STEEL DECK INSTITUTE DESIGN MANUAL FOR COMPOSITE DECKS, FORM DECKS
AND ROOF DECKS.
2. PROVIDE GALVANIZED ROOF DECK WITH THE FOLLOWING MINIMUM PROPERTIES:
1 1/2 INCH DEPTH
20 GAGE THICKNESS
0.234 IN3/FT SECTION MODULUS
0.201 IN4/FT MOMENT OF INERTIA
33,000 PSI YIELD STRESS
3. DECK IS SPECIFIED BASED ON A THREE SPAN CONDITION. FURNISH HEAVIER GAGE DECK IF REQUIRED FOR ONE
OR TWO SPAN CONDITIONS.
4. FASTEN ROOF DECK TO RESIST A NET UPLIFT OF 15 PSF OR AS INDICATED ON THE DRAWINGS.
5. FASTEN DECK TO RESIST A DIAPHRAGM SHEAR FORCE OF 100 POUNDS PER LINEAR FOOT.
COLD-FORMED STEEL
1. DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS AND THEIR CONNECTIONS SHALL BE THE SOLE
RESPONSIBILITY OF THE CONTRACTOR. SUBMIT SHOP DRAWINGS SEALED BY AN ENGINEER LICENSED IN THE
PROJECT STATE. REVIEW OF SHOP DRAWINGS SHALL BE FOR CONFORMANCE WITH THE CONTRACT DOCUMENTS
REGARDING ARRANGEMENT AND SIZES OF MEMBERS AND THE CONTRACTOR'S INTERPRETATION OF THE DESIGN
LOADS AND CONTRACT DOCUMENT DETAILS. SUCH REVIEW SHALL NOT RELIEVE THE CONTRACTOR OF FULL
RESPONSIBILITY FOR THE DESIGN OF THE COLD-FORMED STEEL STRUCTURAL MEMBERS AND THEIR
CONNECTIONS.
2. COLD-FORMED STEEL DESIGN, FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH AISI "SPECIFICATION
FOR DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS" OR "LOAD AND RESISTANCE FACTOR DESIGN
SPECIFICATION FOR COLD-FORMED STEEL STRUCTURAL MEMBERS".
3. COLD-FORMED STEEL STUDS, JOISTS AND ACCESSORIES SHALL BE AS SHOWN IN THE STRUCTURAL DOCUMENTS.
4. COLD-FORMED STEEL STRUCTURAL MEMBERS MAY BE ATTACHED BY EITHER WELDS OR SCREWS SIZED BY THE
MANUFACTURER FOR THE SPECIFIED DESIGN LOADS. SEE THE SPECIFICATIONS.
5. CONTRACTOR SHALL FURNISH COMPLETE FABRICATION AND ERECTION DRAWINGS FOR APPROVAL BY THE
STRUCTURAL ENGINEER PRIOR TO THE COMMENCEMENT OF FABRICATION. INCLUDE PLACING DRAWINGS FOR
FRAMING MEMBERS SHOWING SIZE AND GAGE DESIGNATIONS, NUMBER, TYPE, LOCATION AND SPACING. INDICATE
SUPPLEMENTAL STRAPPING, BRACING, SPLICES, BRIDGING, ACCESSORIES AND DETAILS REQUIRED FOR PROPER
INSTALLATION.
6. AXIALLY LOADED BEARING STUDS SHALL BE POSITIONED SUCH THAT STUD LOCATION IS DIRECTLY UNDER JOIST
BEARING POINT UNLESS NOTED OTHERWISE IN THE STRUCTURAL DOCUMENTS.
7. SPLICES IN AXIALLY LOADED STUDS AND FLOOR OR ROOF JOISTS SHALL NOT BE PERMITTED.
8. WELDING OF COLD-FORMED STEEL SHALL BE IN ACCORDANCE WITH THE STANDARD CODE OF ARC AND GAS
WELDING IN BUILDING CONSTRUCTION.
ROOF PLAN COMPONENTS AND CLADDING
ULTIMATE WIND PRESSURE DIAGRAM
= -30 PSF/+16.0 PSF
= -40 PSF/+16.0 PSF
= -48 PSF/+16.0 PSF
NOTE: WIND PRESSURE BASED ON 50 SQUARE FOOT AREA.
NEGATIVE INDICATES PRESSURE AWAY FROM SURFACE
5'-6"
TYP
5'-6"
(E) BUILDING
(E) PRE-ENGINEERED METAL
BUILDING ROOF, SEE ARCH.
(E) PRE-ENGINEERED
METAL BUILDING ROOF,
SEE ARCH.
5:12
DECK BEARING EL = 3'-8"
SEE NOTE 5
400S162-43 MIN CFM POST,
TYP
(E) PRE-ENGINEERED METAL
BUILDING PURLIN, TYP
(E) PRE-ENGINEERED METAL
BUILDING BEAM BELOW
3.5:123.5:12
12
'-0
"5 E
Q. S
PA
=
31
'-4
"5 E
Q. S
PA
=
31'-4
"1
2'-0
"
±43'-4" FIELD VERIFY
±43'-4" FIELD VERIFY
1:1
2
1:1
2
J2
J2
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
J1
@
1
6" O
.C
.J1
@
1
6" O
.C
.
4
S102
5
S102
(E) BUILDING
0" TYP
(E) METAL BUILDING
ROOF RIDGE
86
'-8" F
IE
LD
V
ER
IF
Y
J2
J2
J2
J2
J2
J2
J2
J2
J2
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
HJ
BCR
1/29/2016
14640GILEAD
THIS DRAWING IS AN INSTRUMENT OF
SERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NO
PART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,
WITHOUT THE EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT.
1700 C
OM
ME
RC
E D
RIV
E, N
W
AT
LA
NT
A, G
EO
RG
IA
30318
T: 404 605 0690
F: 404 605 0890
ww
w.sizem
oregroup.com
© 2011 SIZEMORE GROUP
GILE
AD
-B
LO
OM
FIE
LD
C
OM
PLE
X
RE
NO
VA
TIO
N
19
31
R
OC
KY
C
RE
EK
R
OA
D
MA
CO
N, G
EO
RG
IA
3
12
06
MA
CO
N-B
IB
B C
O.
RE
LE
AS
ED
F
OR
C
ON
ST
RU
CT
IO
N
No
.D
ES
CR
IP
TIO
ND
AT
E
AS SHOWN
Foresite Group, Inc.5185 Peachtree PkwySuite 240Norcross, GA 30092
o | 770.368.1399f | 770.368.1944
w | www.fg-inc.net
01
/2
9/2
01
6
S101
ROOF
FRAMING
PLAN
ROOF PLAN
3/16" = 1'-0"
1
NOTES:
1. SEE S001 FOR STRUCTURAL GENERAL NOTES.
2. SEE ARCH FOR ADDITIONAL INFORMATION AND DIMENSIONS.
3. INDICATES DIRECTIONAL SPAN OF 1 1/2" 20 GA ROOF DECK. SEE 3/S102.
4. INDICATES 400S162-43 MIN JOIST.
INDICATES 600S162-43 MIN JOIST.
INDICATES 400S162-43 MIN BEAM.
5. DECK BEARING ELEVATION IS BASED ON TOP OF EXISTING DECK REFERENCE ELEVATION = 0'-0".
J1
J2
B1
(E) PRE-ENGINEERED METAL
BUILDING PURLIN, TYP
METAL DECKING
CFM JOIST,
SEE PLAN
CFM BEAM,
SEE PLAN(E) METAL DECKING
(E) PRE-ENGINEERED METAL
BUILDING FRAME BEYOND, TYP
DECK BRNG
EL VARIES
12
3.5
5
12
(E) PRE-ENGINEERED METAL
BUILDING BEAM, TYP
8/S102
METAL
DECKING
CFM JOIST
18 GA PLATE
DECK BRNG
EL VARIES
(4) #10 TEK SCREWS
(4) HILTI X-U POWDER
ACTUATED FASTENERS
BLOCKING
BETWEEN FLUTES
(E) DECKING
18 GA PLATE, SIZED
TO FIT METAL
DECKING FLUTES
SEE NOTE 1
A
A
18 GA PLATE
18 GA PLATE
SEE NOTE 1
TEK SCREWS
POWDER
ACTUATED
FASTENERS
(E) METAL
DECKING
BLOCKING BETWEEN
FLUTES
CFM JOIST
SECTION A-A
NOTES:
1. FASTEN 18 GA PLATE TO A MINIMUM OF (2) FLUTES.
(E) PRE-ENGINEERED
METAL BUILDING PURLIN
(E) METAL DECKING
CFM POST,
SEE PLAN
18 GA PLATE
(4) HILTI X-U POWDER
ACTUATED FASTENERS
18 GA PLATE, SIZED TO FIT
METAL DECKING FLUTES
SEE NOTE 1
(4) #10 TEK SCREWS
DECK BRNG
EL VARIES
(E) METAL
DECKING
POWDER
ACTUATED
FASTENERS
18 GA PLATE
SEE NOTE 1
TEK SCREWS
18 GA
PLATE
BLOCKING
BETWEEN
FLUTES
CFM POST
A
A
SECTION A-A
NOTES:
1. FASTEN 18 GA PLATE TO A MINIMUM OF (2) FLUTES.
(E) PRE-ENGINEERED METAL
BUILDING PURLIN, TYP
METAL DECKING
CFM JOIST,
SEE PLAN
CFM BEAM,
SEE PLAN
CFM POST,
SEE PLAN
(E) METAL DECKING
(E) PRE-ENGINEERED METAL
BUILDING FRAME BEYOND, TYP
DECK BRNG
EL VARIES
5
12
(E) PRE-ENGINEERED METAL
BUILDING BEAM, TYP
7/S102
8/S102
12
3.5
SCALE:
DATE:
DRAWN BY:
CHECKED BY:
PROJECT #:
HJ
BCR
1/29/2016
14640GILEAD
THIS DRAWING IS AN INSTRUMENT OF
SERVICE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. NO
PART OF THIS DOCUMENT SHALL BE
REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONICALLY OR
MECHANICALLY, FOR ANY PURPOSE,
WITHOUT THE EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT.
1700 C
OM
ME
RC
E D
RIV
E, N
W
AT
LA
NT
A, G
EO
RG
IA
30318
T: 404 605 0690
F: 404 605 0890
ww
w.sizem
oregroup.com
© 2011 SIZEMORE GROUP
GILE
AD
-B
LO
OM
FIE
LD
C
OM
PLE
X
RE
NO
VA
TIO
N
19
31
R
OC
KY
C
RE
EK
R
OA
D
MA
CO
N, G
EO
RG
IA
3
12
06
MA
CO
N-B
IB
B C
O.
RE
LE
AS
ED
F
OR
C
ON
ST
RU
CT
IO
N
No
.D
ES
CR
IP
TIO
ND
AT
E
AS SHOWN
Foresite Group, Inc.5185 Peachtree PkwySuite 240Norcross, GA 30092
o | 770.368.1399f | 770.368.1944
w | www.fg-inc.net
01
/2
9/2
01
6
S102
FRAMING
DETAILS
TYPICAL ROOF DECK ATTACHMENT (36" WIDE SHEET)
3/4" = 1'-0"
(7) #10 TEK SCREWS
AT SUPPORTS
#10 SELF TAPPING
SCREWS @ 12" AT
SIDE LAPS
#10 TEK SCREWS @ 12" AT
PERIMETER OF BUILDING
36" WIDE SHEET
METAL DECK
CL OF
END
SUPPORT
CL OF
INTERMEDIATE
SUPPORT
S102
3
POST ATTACHMENT AT EXISTING METAL DECKING
3/4" = 1'-0"
7
S102
JOIST ATTACHMENT AT EXISTING METAL DECKING
3/4" = 1'-0"
8
S102
SECTION AT JOIST
3/8" = 1'-0"
5
S102
SECTION AT POST
3/8" = 1'-0"
4
S102