Page 1: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐
Page 2: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐
Page 3: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐
Page 4: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐
Page 5: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐
Page 6: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐

Page 1 of 5 

AL State Port Authority 

Specifications  for  42’ x 66’   Admin Office Trailer 

 

UNIT / MODEL DESCRIPTION 

Complex ( With interior Walls ) 

Description of Unit 

     Nominal: 42' x 66' (3) 13'‐8" x 66'‐0" Module 

 

CODES 

IBC Coded 

NEC Coded 

Business Occupancy 

State Labels:  AL. 

154 MPH VULT Wind Load, Exposure C,  Importance Class II 

Ground Snow Load 16 PSF 

Floor Live Load 50 PSF (Business) 

 

FRAMES 

Detachable Hitch 

12 inch   I‐Beam 

PERIMETER  FRAME  

Std. Axles As Required 

Select Tires 

Tie Down Clips 

 

FLOORS 

Woven Nylon Impregnated Bottom Board 

2x8  Floor Joists   16" O.C. 

Decking ‐ Double 5/8" Sturdifloor 

 Commercial Vinyl Floor Cover (Corlon) WI Welded Scams 

  (@Restroom/Shower Locations Only) 

 YCT  l /8"  Block Tile (12"xl2") 

   

Page 7: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐

Page 2 of 5 

WALLS & PARTITIONS 

Wall Height 8'‐6"  (Upcharge) 

Double Top Plate 

2" x 4" x 8' Interior Walls (Studs 16" O.C.) 

2" x 6" Exterior Walls (Studs 16'' O.C.) 

Standard Trim 

5/8" Vinyl Covered Gypsum  (Type X I Fire Rated) 

FRP (Textured) Wall Covering (8ft. Walls) 

   (@Restooms/Shower Locations Only) 

4" Vinyl Base Cove (Continuous Roll) 

 

INTERIOR DOORS 

36" x 80" (H.C.) 6‐Panel WI Steel Rediframe 

Floor Mounted Door Stops 

Grade 2 ‐ Tell Interior Lever Hardware 

 

ROOF 

Truss Type ‐ Transverse 

IBC Code 

No Overhang on Ends 

No Overhang on Sides 

Truss Spacing ‐ 24" O.C. 

Roof Sheathing ‐ 7/16" OSB 

Roof Covering: 45 Mil. White Rubber 

  (2015 IECC AL) 

12" White Mate‐Line Tape (White EPDM Only) 

Hurricane Straps  (Sides Only) 

Attic Ventilation as Required 

2 ‐ Layer 24" Ridgebeam (As Required) 

3 ‐ Layer ‐ 24" x 3/4" Struct I Ridgebeam 

 

Page 8: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐

Page 3 of 5 

CEILING 

Finished Ceiling Height  7'‐ ll" AFF ‐ (T‐Grid) 

T‐Grid (Mate‐Line Close‐Up  to be by Others) 

 

PLUMBING 

  Single Restroom, Handicap Accessible 

Supply Lines‐ CPVC 

Waste Pipe ‐ PVC (Stub out only ‐ below Fixture) 

All Waste Line ‐ Manifold On‐Site by Others 

Wall Hung Lavatory (Multiple Fixtures) (Mateo Norca wl  Wristblade Levers) 

Vinyl ‐ Anti‐Scald Cover for Trap & Supply 

Toilet ‐ Elongated Bowl (Std Tank Type) 

Toilet ‐ HCI W I Grab Bars (Std Tank Type) 

Toilet Tissue Holder ‐ Single Roll (Bobrick B‐264) 

Urinal ‐ W I Flush Valve 

30 Gallon Water Heater 

Plumb For Refrigerator lcemaker 

 

   

Page 9: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐

Page 4 of 5 

ELECTRICAL 

Three 125 Amp Single Phase Interior Panel Boxes 

Recessed LED Troffers in T‐Grid               

Weatherproof LED Wall Pack WI Photo Cell     (OWP3)     Emergency I Exit LED  Light Combo 

(Directional As Required) 

Emergency/ Exit LED Light WI Remote Head 

300 CFM Exhaust Fans 

Bathroom Vent I LED Lght Combo 

Romex Wiring Per Code (Std) 

MC Cable Above Ceiling Only (T‐Grid) 

Double Switches 

Receptacles Per Print 

Receptacles ‐ GFI Protected 

Receptacles ‐ Exterior GFl Protected 

Heat Tape Receptacle ‐ GFI 

Dedicated 20 Amp Recept @ 48" AFF (For Refrig) 

 

HVAC 

Plenum Wall 

Three 3 Ton Wall Hung AC WI 10 KW Heat 

Factory Std‐ Programmable Thermostat 

Fiberglass Supply Duct (Std.) 

Fiberglass Return Duct (Std). 

T‐Grid Diffuser {Adjustable) 

T‐Grid Diffusers (Non Adjustable) CABINETS 

White Base Lam. Cab.(Lowe's) WI Roll Top 

White Lam. O.H. Cab (Lowe's) WIShelf 

Roll Top I Bull Nose WI 4" Backsplash Countertop 

Double Bowl Stainless Steel Sink & Faucet  (Mateo Norca wl Wristblade Levers) 

 

   

Page 10: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐

Page 5 of 5 

CABINETS 

White Base Laminate Cabinet (Lowes) W/ Roll Top 

White Laminate Overhead Cabinet (Lowes) W/ Shelf 

Roll Top / Bull Nose W/ 4” Backsplash Countertop 

Double Bowl Stainless Steel Sink and Faucet  (Matco Norca w/ Wristblade Levers) 

 

EXTERIOR 

.019 Aluminum W /  OSB  A114 Sides 

Moisture Resist House Wrap ‐  Full Perimeter 

.019 Alum Mansard To Follow Roofline 

 

WlNDOWS 

24 x 54  V/S  Insulated / Tinted 

Vinyl Mini Blinds 

 

EXTERIOR DOORS 

36 x 80  ST / ST ‐ Blank 

36 x 80  ST/ST  4 x 24"  VB 

Lever Hardware 

Closer (Factory Std.) 

 

INSULATION 

R‐19 Floor 

R‐19 Ext. Wall Insulation 

R‐38 Ceiling 

R‐11 Interior Walls 

 

Page 11: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐

Page 1 of 5 

AL State Port Authority 

Specifications  for 24’x54’   Break & Locker Room Trailer 

 

UNIT / MODEL DESCRIPTION 

Break / Shower I Toilet Unit 

Description of Unit 

 24' x 54' (2) 11'‐8" x 54'‐0" Module 

 

CODES 

IBC Coded 

NEC Coded 

Business Occupancy 

State Labels:  AL. 

154 MPH VULT Wind Load, Exposure C,  Importance Class II 

Ground Snow Load 16 PSF 

Floor Live Load 50 PSF (Business) 

 

FRAMES 

Detachable 1‐ Hitch 

12 inch   I‐Beam 

PERIMETER  FRAME  

Std. Axles As Required 

Select Tires 

Tie Down Clips 

 

FLOORS 

Woven Nylon Impregnated Bottom Board 

2x8  Floor Joists   16" O.C. 

Decking ‐ Double 5/8" Sturdifloor 

 Commercial Vinyl Floor Cover (Corlon) WI Welded Scams 

  (@Restroom/Shower Locations Only) 

 YCT  l /8"  Block Tile (12"xl2") 

   

Page 12: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐

Page 2 of 5 

WALLS & PARTITIONS 

Wall Height 8'‐6"  (Upcharge) 

Double Top Plate 

2" x 4" x 8' Interior Walls (Studs 16" O.C.) 

2" x 6" Exterior Walls (Studs 16'' O.C.) 

Standard Trim 

518" Vinyl Covered Gypsum (Type X I Fire Rated) 

FRP (Textured) Wall Covering (8ft. Walls) 

  (@Restooms/Shower Locations Only) 

4" Vinyl Base Cove (Continuous Roll) 

 

INTERIOR DOORS 

36" x 80" (H.C.) 6‐Panel WI Steel Rediframe 

Floor Mounted Door Stops 

Grade 2‐ Tell Interior Lever Hardware 

 

ROOF 

Truss Type ‐ Transverse 

IBC Code 

No Overhang on Ends 

No Overhang on Sides 

Truss Spacing ‐ 24" O.C. 

Roof Sheathing ‐ 7/16" OSB 

Roof Covering: 45 Mil. White Rubber 

  (2015 IECC AL) 

12"White Mate‐Line Tape (White EPDM Only) 

Hurricane Straps {Sides Only) 

Attic Ventilation as Required 

2 ‐ Layer 24" Ridgebeam (As Required) 

3 ‐ Layer ‐ 24" x 3/4" Struct I Ridgebeam 

 

Page 13: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐

Page 3 of 5 

CEILING 

Finished Ceiling Height 7'‐ ll" AFF‐ (T‐Grid) 

T‐Grid (Mate‐Line Close‐Up  to be by Others) 

 

PLUMBING 

  Single Restroom, Handicap Accessible 

Multi‐Station Restroom 

Supply Lines‐ CPVC 

Waste Pipe ‐ PVC (Stub out only ‐ below Fixture) 

All Waste Line ‐ Manifold On‐Site by Others 

Wall Hung Lavatory (Multiple Fixtures) (Mateo Norca wl  Wristblade Levers) 

Vinyl ‐ Anti‐Scald Cover for Trap & Supply 

Toilet ‐ Elongated Bowl (Std Tank Type) 

Toilet ‐ HCI W I Grab Bars (Std Tank Type) 

Toilet Tissue Holder ‐ Single Roll (Bobrick B‐264) 

Urinal ‐ W I Flush Valve 

30‐ Gallon Water Heater 

Shower (Std.) W/Scald Proof Valve & Curtain 

HC Shower WISeat,HC Bars,Curtain (Scald Proof) 

Plumb For Refrigerator lcemaker 

 

   

Page 14: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐

Page 4 of 5 

ELECTRICAL 

Two 125 Amp Single Phase Interior Panel Boxes 

Recessed LED Troffers in T‐Grid              

Weatherproof LED Wall Pack WI Photo Cell     (OWP3)    

Emergency I Exit LED  Light Combo (Directional As Required) 

Emergency/ Exit LED Light WI Remote Head 

300 CFM Exhaust Fans 

Bathroom Vent I LED Lght Combo 

Romex Wiring Per Code (Std) 

MC Cable Above Ceiling Only (T‐Grid) 

Double Switches 

Receptacles Per Print 

Receptacles ‐ GFI Protected 

Receptacles ‐ Exterior GFl Protected 

Heat Tape Receptacle ‐ GFI 

Dedicated 20 Amp Recept @ 48" AFF (For Refrig) 

 

HVAC 

Plenum Wall 

Two 3 Ton Wall Hung AC WI 10 KW Heat 

Factory Std‐ Programmable Thermostat 

Fiberglass Supply Duct (Std.) 

Fiberglass Return Duct (Std). 

T‐Grid Diffuser {Adjustable) 

T‐Grid Diffusers (Non Adjustable) CABINETS 

White Base Lam. Cab.(Lowe's) WI Roll Top 

White Lam. O.H. Cab (Lowe's) WIShelf 

Roll Top I Bull Nose WI 4" Backsplash Countertop 

Double Bowl Stainless Steel Sink & Faucet  (Mateo Norca wl Wristblade Levers) 

 

   

Page 15: P:PROJECTSAUTOMOBILE TERMINALE26 - MAINTENANCE … · ROOF Truss Type ‐ Transverse IBC Code No Overhang on Ends No Overhang on Sides Truss Spacing ‐ 24" O.C. Roof Sheathing ‐

Page 5 of 5 

EXTERIOR 

.019 Aluminum WI OSB A114 Sides 

Moisture Resist House Wrap‐  Full Perimeter 

.019 Alum Mansard To Follow Roofline 

 

WlNDOWS 

24x54 V/S Lnsulated Bffinted 

Vinyl Mini Blinds 

 

EXTERIOR DOORS 

36x80 Steet'Steel ‐ Blank 

36x80  ST/ST  4x24"  VB 

Lever Hardware 

Closer (Factory Std.) 

 

INSULATION 

R‐19 Floor 

R‐19 Ext. Wall Insulation 

R‐38 Ceiling 

R‐11 Interior Walls