ppa swing gate openers catalog - 2011

4

Upload: ppa-industria

Post on 09-Feb-2016

249 views

Category:

Documents


8 download

DESCRIPTION

Read and download our 2011 Swing Gate Openers Catalog.

TRANSCRIPT

Page 1: PPA Swing gate openers Catalog - 2011
Page 2: PPA Swing gate openers Catalog - 2011

UNIQUE

PISTON

Opening / Close Time (90º)*Opening / Closing Cycles per Hour

HPPiston rod length

End-of-stroke systemReduction ratio

Opening / Close Time (90º)*Opening / Closing Cycles per Hour

HPPiston rod length

End-of-stroke systemReduction ratio

Opening / Close Time (90º)*

Opening / Closing Cycles per HourHP

Piston rod lengthEnd-of-stroke system

Reduction ratio

10 seconds201/4330 mmEncoder1:26

15 seconds201/40.75 up to 1.25 mInductive Limit Switch1:26

11 seconds (350-mm piston rod);17 seconds (550-mm piston rod).601/2350 / 550 mmEncoder1:26

17 seconds201/2550 mmEncoder1:26

15 seconds201/40.75 up to 1.25 mEncoder1:26

Piston

Unique

Piston 1000

Unique Digital

THOR

- Storage Capacity: 1024 telephone numbers;- Two settable outputs (pulse / retention);- Two inputs;- Sending of SMS to five distinct telephone numbers;- Outputs activated by Free Call;- PC communication by USB cable;- Real-time event monitoring;- Event history stored on a database.

CONTATTOCell phone-activated receiver

- Storing capacity: up to 999 ProxCards and 999 user codes. Each user code is linked to a ProXCard, i.e., both are stored on the same specific memory cluster;

- Inputs to Two ProxCard Readers;- Sequential or addressable storage of remote controls / user codes;- Four-digit, seven-segment display;- Numeric / function keypad;- Three stand-alone outputs with solid state relay (SSR);- Outputs settable as pulse (NO / NC), retention, timed (NO / NC) and

panic (NO / NC);- Erases each remote control at a time (sequentially or by address) or all

remote controls at once;- Blocking and unblocking of remote controls / user codes, without

erasing them;

MATRIX PROProxCard Reader

- Fifteen setting groups which can be used to define permissions of access to specific users;

- Master code, used for programming (can be changed anytime);

- Compatible to Transfer, with five positions on the memory available to backup of ProxCards and user codes, as well as to settings backup.

*Maximum time to the motor entirely pull / push.the piston rod.

*Maximum time to the motor entirely pull / push the piston rod.

*Maximum time to the motor entirely pull / push the piston rod.

Page 3: PPA Swing gate openers Catalog - 2011

Opening / Close Time (90º)*

Opening / Closing Cycles per HourHP

Piston rod lengthEnd-of-stroke system

Reduction ratio

Opening / Close Time (90º)*Opening / Closing Cycles per Hour

HPPiston rod length

End-of-stroke systemReduction ratio

Opening / Close Time*Opening / Closing Cycles per Hour

HPEnd-of-stroke system

Reduction ratioLargo del portón

5 seconds (350-mm piston rod);8.5 seconds (550-mm piston rod).601/2350 / 550 mmEncoder1:26

28 seconds601/2750 mmEncoder1:26

28 m/min601Inductive Limit Switch1:40From 3 meters on

PIVO CONDOMINIUM

PIVO INDUSTRIAL

LIGER UNIVERSAL 1HP

SISTEMA LINK PIVO

SPI - SWING GATE SYSTEM ENHANCED WITH VARIABLE-FREQUENCY DRIVE

DIGITAL DUPLA

- Communication between ECUs through RS-485 network;- Bivolt;- Variable-Frequency Drive (Inverter);- Adjustable speed;- High-voltage indicator;- Reed Digital (Encoder Hall System) running indicator;- Easy and fast installation through DIP switches individual function selection;- Push-button, external receiver and photocell (photo-eye) inputs;- Outputs to courtesy light and electromagnetic lock.

- Embedded RF 433,92MHz Module Receiver;- Code Learning;- Capacity to up to 160 remote controls, regardless if either the two buttons or only one

have been programmed;- Individual programming to each remote control.- Input Accessories: - Push Button; - Photocells; - Loose RF receiver module.- Output Accessories: - Warning light module; - Lock module; - Courtesy light module.- Control of the motor: - Soft start; - Electronic clutch; - Electronic break;- Individual memorization of the opening / closing path time to the motors which delay on

opening and on closing.

- Master ECU (Facility TOP ECU with embedded RF module);- Slave ECU (Facility Link* ECU without RF module);- RS-485 Serial communication network (2 serial modules**; one to each ECU, linked through

communication cable);- Compatible to Encoder Hall System and Inductive limit switch system.

* Similar to New Facility ECU;** Modules sold apart.

ECUS FOR DOUBLE SWING GATE OPENERS

MATRIX

- Storing capacity: up to 999 remote controls and 999 user codes.Each memory cluster can store a remote control and / or a user code;

- Addressable or sequential recording of remote controls / user codes;

- Four-digit, seven-segment display;- Numeric / function keypad;- Three stand-alone outputs with solid state relay (SSR);- Outputs settable as pulse (NO / NC), retention, timed (NO / NC)

and panic (NO / NC);- Erases each remote control at a time (sequentially or at random)

or all remote controls at once;- Blocking and unblocking of remote controls / user codes, without

erasing them;

Remote control ReceiverCP-1000Access Control System

- Fifteen setting groups which can be used to define permissions of access to specific users;

- Master code, used for programming (can be changed anytime);

- Compatibility to four-button remote control.

*Maximum time to the motor entirely pull / push the piston rod.

*Maximum time to the motor entirely pull / push the piston rod.

*Three-meter-long gates.

- Storing capacity: 1000 user codes (One ProxCard and one remote control per user);- Connection capacity:- Four remote control receivers (each one with four outputs);- Twelve ProxCard readers;- Four relay modules (each one with four outputs).- Eight settable command inputs;- Storage of up to 1200 events on its memory;- Events shown on display;- PC connection via specific software;- Compatible to PS2 keyboard;- Blocking and unblocking of remote controls or ProxCards, without erasing them from memory;- ‘Guard System’ – used to monitor the presence of doorkeepers and watchmen.

Page 4: PPA Swing gate openers Catalog - 2011

Automatic gate openers - Alarm systems - Automatic door openers Automatic Barriers - Electric MotorsAdditional info on WWW.PPA.COM.BR

.com/grupoppa |

- Receiver used on PPA gate and sliding glass door openers;

- Increases the remote controls storage capacity;- Easy installation;- Available on 292 and 433.92 MHz SAW.

ALCANCE

ACESSO ACESSO PRO

RELAY MODULE PUSHBUTTON

MODULE

- Wireless control access keypad; it can also be used to activate alarm systems, door and gate openers, automatic barriers and electromagnetic locks;

- Code Learning;- 433.92 MHz operating frequency band (Crystal oscillator and Phase-Locked

Loop – PLL)- Lithium battery;- 9 or 12-volt power supply*: - Nine user codes and one Master code;- 1 PGM output with negative signal;- The periods of time the device keeps active are individually set.

*Not

pro

vided

.

- Prox card reader, used both to control access to restrict areas and to run sliding glass doors openers, gate openers and electric locks;

- Self-learning rolling code;- Frequency: 433.92;- 12-volt power supply*: - Storing capacity: 100 ProxCards (99 user cards and 1 master

card).

The

imag

es c

onta

ined

on

this

cat

alog

are

mer

ely

repr

esen

tatio

nal a

nd il

lust

rativ

e an

d ar

e no

t int

ende

d to

refle

ct a

ctua

l vie

ws

from

any

par

ticul

ar p

rodu

ct. P

PA re

serv

es th

e rig

ht to

cha

nge

its p

rodu

cts,

as

wel

l as

spec

ifica

tions

and

feat

ures

, at i

ts s

ole

disc

retio

n w

ithou

t prio

r no

tice.

Acc

esso

ries

sold

apa

rt. T

o a

corre

ct in

stal

latio

n an

d us

e, a

lway

s re

fer t

o th

e pr

oduc

t tec

hnic

al m

anua

l, av

aila

ble

on th

e w

ebsi

te w

ww.

ppa.

com

.br O

nly

a pe

rson

trai

ned

by P

PA m

ust p

erfo

rm in

stal

latio

n, m

aint

enan

ce a

nd s

uppo

rt se

rvic

es o

n th

e eq

uipm

ents

.GOOD LIGHT- Device to activate gate / door openers by using the car’s headlight;- In order to open or close the gate, one must only activate the headlight high beam;- 12-V Power Supply;- Protection against power supply polarity inversion;- 433.92 MHz Transmission Frequency;- SAW-locked circuit.

TOK PICCOLO MINI

- Reinforced grip;- Buttons embedded on the cover;- Exclusive battery holding system; - Circuit board with surface-mount

components;- Resistant to falls and impacts;- Available on 292 MHz, 433.92 MHz

and 433.92 MHz SAW.

- Four stand-alone buttons;- Increased stability of the signal

to a better radio range;- Increased resistance to falls

and impacts;- Used to activate alarm systems,

as well as automatic gate and door openers;

- 433,92 MHz SAW.

- Programming via remote control;- Storage capacity: up to 160 Remote

Controls;- End-of-stroke system: Inductive Limit

Switch / Encoder;- Courtesy light module, electromagnetic

lock module and warning light module outputs:

- Input Accessories:- Push Button;- External receiver;- Photocells.

- Adjustable speed;- End-of-stroke system: Inductive Limit Switch /

Encoder / ‘Hybrid’;- Programming via DIP Switch:- Output Accessories: - Courtesy light; - Electromagnetic lock;- Input Accessories: - External receiver; - Push Button; - Photocells.

- Programming via DIP Switch:- Storing capacity: 160 remote controls;- End-of-stroke system: Inductive Limit Switch /

Encoder / ‘Hybrid’;- Courtesy light output;- Input Accessories:- Push Button;- Photocells.

- Programming via DIP Switch:- Storing capacity: 160 remote controls;- End-of-stroke system: Inductive Limit Switch /

Encoder / ‘Hybrid’;- Output Accessories:- Courtesy light;- Electromagnetic lock;- Warning light.- Input Accessories:- External receiver;- Push Button;- Photocells;- RS 485 communication device.

- Programming via trimmer: - Brake setting; - Strength setting; - Automatic timed closing;- Opening / Closing time.- Storing capacity: 1000 remote controls;- End-of-stroke system: Inductive Limit Switch;

- Programming via trimmer:- Automatic timed closing;- Strength adjustment;- Deceleration adjustment;- Storing capacity: 170 remote controls;- End-of-stroke system: Inductive Limit Switch;- Input Accessories:- External receiver;- Push Button;- Photocells.- Output Accessories:- Courtesy light;- Electromagnetic lock.

ELECTRONIC CONTROL UNITIES

FACILITY FACILITY 3 TRIMPOTS

‘FACILITY’ LINE

TOP 4 TRIMPOTS

TOPTOP LIGHT

‘TOP’ LINE

TRIFLEX

- Input Accessories: - External receiver; - Push Button; - Opening command; - Closing command; - Photocells.- Output Accessories: - Electromagnetic lock; - Courtesy light; - Warning light.