powerlogic ® factory assembled enclosures safety reliability energy efficiency

27
PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

Upload: monica-harmon

Post on 17-Dec-2015

222 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

PowerLogic® Factory Assembled Enclosures

Safety Reliability Energy Efficiency

Page 2: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

2Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® Factory Assembled Enclosures Simplify retrofit installations

Greatly improve speed of system startup

Free-standing or wall-mounted

Professionally crafted, factory tested, pre-wired

Designed to current NEC and UL standards

Equipped with hazard and safety labels

Efficient panel layout and well marked terminals reduce wiring errors and needless troubleshooting

Complete with necessary documentation and mounting hardware for quick and easy installation.

for metering, communications, and control applications

Page 3: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

3Copyright © 2007 Schneider Electric. All rights reserved

Factory Assembled Enclosures Type Guide:

NEMA Type 1- for indoor use to provide a degree of protection against contact with the enclosed equipment or locations where unusual service conditions do not exist.

NEMA Type 12 - for indoor use to provide a degree of protection against dust, falling dirt, and dripping non-corrosive liquids.

NEMA TYPE 3R - for outdoor use to provide a degree of protection against falling rain, and it is undamaged by the formation of ice.

NEMA Type 4 - for indoor and outdoor use to provide a degree of protection against dust, rain, splashing water, hose directed water, and it is undamaged by the formation of ice. A strip heater is included to prevent condensation.

Page 4: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

4Copyright © 2007 Schneider Electric. All rights reserved

Enclosure Applications

METERING

COMMUNICATIONS

CUSTOM CONTROL ENCLOSURES

DRAWOUT RETROFIT CRADLES

Page 5: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

5Copyright © 2007 Schneider Electric. All rights reserved

Metering Enclosures

Page 6: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

6Copyright © 2007 Schneider Electric. All rights reserved

METERING Service Entrance/Utility Revenue Main/Critical Circuit Main & Multiple Feeders Secondary Main Feeder High Density Metering

Page 7: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

7Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® ION8600 Factory Assembled Enclosures --Type 3R Outdoor

Ideal for monitoring electrical distribution networks, service entrances and substations requiring revenue accuracy and power quality analysis capabilities.

UL/CUL 508A listed

Assemblies include meters and devices wired to terminal blocks, voltage disconnect(s) and current transformer (CT) shorting blocks.

Serial & Ethernet Communications are options for all units.

Digital and/or Analog Input/Output (I/O) are options for all units.

Units are available with optional 10-Pole test switch installed for voltage and CT testing, and calibration.

Tailored to any meter system voltage type :

▼ 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase

▼ 240V, 480V & 600V Delta Three-Phase

Units are available with optional built in bar type CT’s installed (Transocket Lever Bypass).

Wall mountable and easy to install, using concealed holes in the back of the enclosure.

Equipped with pad-lockable latch and removable door

Custom engraved nameplates are available for all units.

Note: For Type 3R & 4 enclosures if unit uses door mounted equipment, this equipment will be mounted on an inner swing door. The outer protective door must be opened to access door mounted equipment.

Page 8: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

8Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® CM4250/4000T FactoryAssembled Enclosures -- Type 12 & 4

Ideal metering solution for monitoring key distribution points and sensitive loads requiring revenue accuracy and power quality analysis capabilities for critical loads.

Can monitor up to four separate sources/loads per panel utilizing one meter per load.

UL/CUL 508A listed

Assemblies include meters and devices wired to terminal blocks, voltage disconnect(s), and current transformer (CT) shorting blocks.

Serial & Ethernet Communications are options for all units.

Digital and/or Analog Input/Output (I/O) are options for all units.

Tailored to any meter system voltage type:

▼ 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase

▼ 240V, 480V & 600V Delta Three-Phase

Supports Single or Multiple Voltage Sources for Indoor (Type 12) & Outdoor (Type 4) applications.

Wall mountable and easy to install using concealed holes in the back of the enclosure.

Equipped with concealed hinged door, and universal pad-lockable latch.

Page 9: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

9Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® ION7550/7650 Factory Assembled Enclosures -- Type 12 & 4

The ION7550 and ION7650 metering enclosures are an ideal metering solution for monitoring key distribution points and sensitive loads requiring revenue accuracy and power quality analysis capabilities.

Pad-lockable, concealed hinge industrial enclosures

UL/CUL 508A listed

Integrated display meters capable of monitoring up to four separate sources/loads per panel utilizing one meter per load.

Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s), and current transformer (CT) shorting blocks.

Serial & Ethernet Communications are options for all units

Digital and/or Analog Input/Output (I/O) are options for all units.

Tailored to any meter system voltage type :

▼ 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase

▼ 240V, 480V & 600V Delta Three-Phase

Supports Single or Multiple Voltage Sources for Indoor (Type 12) & Outdoor (Type 4) applications.

Wall mountable and easy to install using concealed holes in the back of the enclosure.

Carbon steel construction, with industry standard ANSI 61 gray powder-coat finish.

Page 10: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

10Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® CM4250/4000T Main with PM820 Feeder Factory Assembled Enclosures -Type 12&4

Ideal for monitoring key distribution points and sensitive loads requiring revenue accuracy and power quality analysis capabilities plus feeder units allow for primary main service voltage monitoring in addition to separate voltage monitoring for the loads which share the same voltage source.

Main meter and feeders will be wired for Inputs/Outputs. 16-Digital Inputs, 3-Relay Outs, KYZ Out, 3-Digital Outputs, 1-Analog Output, 1-Analog Input wired to terminal blocks (Includes default I/O + IOX2411 + IOC44 + DC supply). Each feeder will have 1-Digital Input, and 1-Digital Output wired to terminal blocks. (Includes Feeder default I/O only)

UL/CUL 508A listed

Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s), and 8-pole current transformer (CT) shorting blocks on the main and 6-pole CT shorting blocks on feeders.

One 100BaseFX, 10/100BaseT equipped meter. CAT5E & Fiber cabinet will terminate directly on the meter. (wired to terminal blocks) Each meter RS-485 port will be daisy chained together. (5 OUT for 5 terminal blocks total).

Up to one main service and eight separate loads per panel utilizing one meter per load.

Page 11: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

11Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® ION7550/7650 Main with ION6200 Feeder Factory Assembled Enclosures -Type 12&4

Ideal for monitoring key distribution points and sensitive loads requiring revenue accuracy and power quality analysis capabilities plus feeder units allow for monitoring for the loads which share the same voltage source. loads per panel utilizing one meter per load.

UL/CUL 508A listed

Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s), and 8-pole current transformer (CT) shorting blocks on main and 6-pole CT shorting blocks on feeders.

Main meter will be wired for Inputs/Outputs, feeders will not. 16 Digital Inputs, 4 Digital Outputs, and 3 Relay OUtputs wired to terminal blocks and 4 Analog Inputs and 4 Analog Outputs wired to terminal blocks.

One 10 Base-T Ethernet and 10 Base-FL equipped meter. Cate 5E and fiber cables will terminate directly on meter. Each RS-485 port will be daisy chained together and wired to terminal blocks.

Tailored to any meter system voltage type:

▼ 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase

▼ 240V, 480V & 600V Delta Three-Phase

Each unit is capable of monitoring up to one main service and eight separate

Page 12: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

12Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® CM3000 Series Factory Assembled Enclosures – Type 12 & 4

The CM3250 and CM3350 enclosures are an ideal metering solution for monitoring key distribution points and sensitive loads requiring both revenue accuracy and power quality analysis capabilities.

Remote display meters are capable of monitoring four separate sources/loads per panel utilizing one meter per load.

Multiple CM3250 and CM3350 units can be networked together via Ethernet or RS-486 using Modbus communications protocol.

Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s), and current transformer (CT) shorting blocks.

Tailored to any meter system voltage type:

▼ 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase

▼ 240V, 480V & 600V Delta Three-Phase

UL/CUL 508A listed

Digital and/or Analog Input/Output (I/O) are options for all units.

Wall mountable and easy to install using concealed holes in the back of the enclosure.

Page 13: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

13Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® ION7300 Series Factory Assembled Enclosures-- Type 12 & 4

Ideal metering solution for high accuracy feeder monitoring and secondary mains. These pad-lockable enclosures capable of monitoring up to four separate sources/loads per panel utilizing one remote display or integrated display meter per load.

Multiple ION7300 series units can be networked together via Ethernet or RS-485 using Modbus®, ION® or other industry standard communication protocols.

Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s), and current transformer (CT) shorting blocks.

Digital and/or Analog Input/Output (I/O) are options for all units.

UL/CUL 508A listed

Tailored to any meter system voltage type:

▼ 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase

▼ 240V, 480V & 600V Delta Three-Phase

Wall mountable and easy to install using concealed holes in the back of the enclosure.

Serial & Ethernet Communications are options for all units.

Page 14: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

14Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® ION6200 Factory Assembled Enclosures – Type 12 & 4

Ideal metering solution for high accuracy feeder monitoring and submetering and capable of monitoring up to four separate source/loads per panel utilizing one meter with remote display per load.

Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s), and current transformer (CT) shorting block(s).

Serial & Ethernet Communications are options for all units.

Digital and/or Analog Input/Output (I/O) are options for all units.

Tailored to any meter system voltage type:

▼ 208Y/120V, 480Y/277V & 600Y/347V Wye Three-Phase

▼ 240V, 480V & 600V Delta Three-Phase

Wall mountable

Pad-lockable

UL/CUL 508A listed

Custom engraved nameplates are available for all units.

Page 15: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

15Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® PM800 Series Factory Assembled Enclosures – Type 12 & 4

Ideal metering solution for high accuracy feeder monitoring and submetering that are well suited for monitoring up to four source/loads fed from the same or separate voltage sources.

Assemblies include meters & devices wired to terminal blocks, voltage disconnect(s) and current transformer (CT) shorting block(s).

Serial & Ethernet Communications are options for all units.

Digital and/or Analog Input/Output (I/O) are options for all units.

Tailored to any meter system voltage type:

▼ 120/208V, 277/480V & 347/600V Wye Three-Phase

▼ 240V, 480V & 600V Delta Three-Phase

Wall mountable,pad-lockable and UL/CUL 508A listed.

Page 16: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

16Copyright © 2007 Schneider Electric. All rights reserved

High Density Metering Selection Criteria

Will the enclosure be located in clean/dust free environment?

If NO, use NEMA Type 12

Will the unit be connected to a up stream 5KA Current limiting device/disconnect?

If NO, use “Light Industrial” enclosures that includes 200KA Class CC disconnect.

Is your system type >=240VAC? If NO, our economical commercial grade enclosures

might be a great alternative for your application.

NOTE: Please use PowerLogic Factory Assembled Enclosures Doc#3000CT0801 to help you select the correct enclosure for your application.

Page 17: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

17Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® ION6200/PM820 Power MeterFactory Assembled Enclosures – Type 1

The Light Industrial Power Meter enclosure is an ideal high density metering solution for commercial and light industrial applications. such as office parks, condominiums, apartments, retail centers and others requiring revenue accuracy.

Light Industrial pad-lockable enclosures are capable of monitoring up to twelve separate loads per panel utilizing on remote display meter per load.

Multiple Light Industrial units can be networked together via serial RS-485 communicatiosn using Modbus or ION communication protocol.

Assemblies include meters & devices wired to terminal blocks, fusible voltage disconnect(s), and ring current transformer (CT) shorting block(s).

Tailored to any meter system voltage type:

▼ 208Y/120V, 480Y/277V and 600Y/347V Wye Three-Phase

▼ 240V, 480V & 600V Delta Three-Phase

Wall mountable and easy to install using concealed holes in the back of the enclosure.

Digital and/or Analog Input/Output (I/O) options are not available on light industrial enclosures.

Carbon steel construction, with industry standard ANSI 61 gray powder-coat finish.

Page 18: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

18Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® High Density Metering (HDM) Enclosures – Type 1 & 3R

The High Density Metering (HDM) cabinets are an ideal low installed cost solution for indoor commercial applications where a small footprint is required.

Available in single, four meter column width, eight meter and sixteen meter configurations.

Painted to match ANSI 49 specifications

Equipped with ION6200, PM750 or PM210 power meters.

The flexible 1-Meter HDM is available in Type 3R (outdoor) when equipped with ION6200 or Type 1 (indoor) cabinets and can be equipped with either PM210, PM750 or ION6200 meters.

PowerLogic High Density Metering 4-metercolumn width cabinets are the ideal spacesaving solution.

PowerLogic High Density Meteringsolutions enable you to monitor, allocate,and invoice your facility’s electrical usage.

Page 19: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

19Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® MCM Factory Assembled EnclosuresType 12 & 4

Ideal sub-metering solution for commercial and industrial applications where multiple panelboards are fed from the same voltage source.

Multiple MCM units can be networked together via RS-485 using Modbus communication protocol.

Assemblies include meters & devices wired to terminal blocks, voltage disconnect, and current transformer (CT) shorting block(s).

Tailored to any meter system voltage type:

▼ 208Y/120V, 480Y/277V and 600Y/347V Wye Three Phase

▼ 240V & 480V Delta Three-Phase

Wall mountable and easy to install using concealed holes in the back of the enclosure.

Carbon steel construction, with industry standard ANSI 61 gray powder-coat finish.

Capable of monitoring up to eight separate loads per panel.

Page 20: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

20Copyright © 2007 Schneider Electric. All rights reserved

Communications Enclosures

COMMUNICATIONS Ethernet Gateways ION7550RTU NR&D

Page 21: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

21Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® EGX Gateway CommunicationsFactory Assembled Enclosures – Type 12 & 4

Ideal solution for communications integration for high-speed access to critical information and providing Ethernet connectivity to downstream connected, new and existing system wide serial equipment.

Assemblies include devices wired to terminal blocks and 1-pole circuit breaker for 120VAC control power.

Available for either EGX100 or EGX400 gateways

ANSI 61 gray finish

Pad-lockable

UL listed

Wall mountable

Supports Indoor (Type 12) & Outdoor (Type 4) applications for up to 3 devices.

Page 22: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

22Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® ION7550RTU Factory Assembled Enclosures – Type 12 & 4

Ideal solution for communications integration and data consolidation for high speed access to critical information and providing Ethernet connectivity to downstream-connected, devices. communication protocols.

Assemblies include devices wired to terminal blocks and 1-pole circuit breaker for 120VAC control power.

Supports for Indoor (Type 12) & Outdoor (Type 4) applications up to 4 devices.

ANSI 61 gray finish

Pad-lockable

UL listed

Wall mountable

Multiple ION7550RTU units can be networked together via Ethernet or RS-485 using Modbus®, ION® or other industry standard

Page 23: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

23Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® NR&D Factory Assembled Enclosures – Type 12 & 4

The Niobrara Research &Development (NR&D) Industrial communications enclosures for QUCM, EPE5, SPE4 and MEB are ideal solutions for non-industry standard communications integration and data consolidation for high speed access to critical information and can serve as standalone data concentrators and protocol translators for third party systems such as Cutler Hammer and Caterpillar.

Assemblies include devices wired to terminal blocs and 1-pole circuit breakers for 120VAC control power.

Equipped with GFCI receptacle for convenience.

Available with multiple devices per panel.

UL listed

Pad-lockable

Wall mountable

Carbon steel construction

ANSI 61 gray finish

Custom engraved nameplates

Multiple NR&D units can be networked together via Ethernet or RS-485 using Modbus, industry standard and proprietary communication protocols.

Page 24: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

24Copyright © 2007 Schneider Electric. All rights reserved

Custom Control Cabinets

Custom enclosures offer turn key integrated control solutions

Industrial rated UL listed enclosures.

Extensive experience in energy and power management, automatic control, integrated supervisory control, and data acquisition (SCADA).

Our design services will meet your system specifications and requirements.

Designed to fit any environment - Indoor (Type 1 & 12) & Outdoor (Type 3R & 4) applications.

Page 25: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

25Copyright © 2007 Schneider Electric. All rights reserved

Custom Control Enclosure Solutions:

Switchgear Transfer Control Panels

Generator Control Panels

Load Shed Control Panels

Sequence of Events Recording (SER) Panels

Control System Mimic Panels

Lighting Control Interface Panels

Emergency Power Supply Systems (EPSS) Control Panels

Water, Air, Gas, Electrical, and Steam (WAGES) Monitoring Panels

Input Status Monitoring & Alarming Panels

Remote Annunciator Control Panels

Industrialized PC’s, Touch Screens (Magelis), and Human Machine Interfaces (HMI’s) with Custom System Graphics.

Server Rack and Network Equipment (Servers, Switches, UPS’s) for Energy Management Systems.

Programmable Logic Controller (PLC) Control Panels (Hot Standby, Relay Control, Data Concentration, etc…)

Serial, Ethernet, and Cellular Wireless Systems

Remote Operator Control Panels

Page 26: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

26Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® PM700/PM800 Series DrawoutRetrofit Cradles

The PM700 and PM800 series Drawout Retrofit Cradles allow easy installation of PM710, PM750, PM810, PM820, PM850 and PM870 power meters with integrated display into any switchboard draw-out case.

Ideal for retrofits - most installations can be performed without de-energizing the circuit or re-wiring.

Utilizing factory tested, pre-wired retrofit cradles allows advanced metering technology upgrades and eliminates risk of mis-wiring or handling old asbestos wiring.

Meter control power is required and 18” pigtail is provided for L, N and G connection.

Equipped with plastic cover, and universal lead seal latch. Assemblies include meter wired to cradle terminals.

NOTE: To better serve you please have the existing cradle type (i.e. GE, Westinghouse, etc.)

Page 27: PowerLogic ® Factory Assembled Enclosures Safety Reliability Energy Efficiency

27Copyright © 2007 Schneider Electric. All rights reserved

PowerLogic® ION6200 and ION7300 SeriesDrawout Retrofit Cradles

The ION6200 and ION7300 series Drawout Retrofit Cradles allow easy installation of ION6200, ION7300, ION7330 and ION7350 power meters with integrated display into any switchboard draw-out case.

Ideally suited for older facilities since most installations can be performed without de-energizing the circuit or re-wiring.

Utilizing factory tested, pre-wired retrofit cradles allows advanced metering technology upgrades and eliminates risk of mis-wiring or handling old asbestos wiring.

Meter control power is required and 18” pigtail is provided for L, N and G connection.

Equipped with plastic cover, and universal lead seal latch. Assemblies include meter wired to cradle terminals.