powerlogic ® e5600 power and energy meter. schneider electric 2 - north american operating division...
TRANSCRIPT
PowerLogic® E5600 power and energy meter
Schneider Electric 2- North American Operating Division
A PowerLogic system can help you…
Submeter and bill tenants and departments● Accurate, economical energy monitoring lets you bill tenants for their actual
usage and eliminate previously uncontrolled utility expenses.
Accurately allocate costs ● Monitor individual cost centers, identify opportunities for demand control, and
check energy consumption patterns. Its low total cost of cost of ownership means you can easily place a PowerLogic E5600 wherever you need it.
Reduce energy costs● Verify the effectiveness of energy efficiency efforts by
monitoring key points within your power distribution system. Collect the data you need to ensure contractual obligations are met and use the PowerLogic E5600 to help achieve LEED certification and green building status.
Schneider Electric 3- North American Operating Division
E5600 Product Overview
● Easy to specify, install and wire
● Economical to purchase and own
● Simple to configure and use
● Revenue accurate energy and power measurements
● High quality construction and self diagnostics enhance reliability
● Industry-standard communications
● Excellent upgrade path helps you save money on future expansion
●Part of a complete tenant metering solution
Schneider Electric 4- North American Operating Division
Target customersAn ideal choice for:
●Office buildings●Multi-use commercial
●Malls
●Retail operations
●Universities and colleges
●Government facilities
●Hotels
●Multi-use residential
●Airports ●Other transportation facilities
Buildings
Retail
Multi-Residential
Transportation
Institutions
Schneider Electric 5- North American Operating Division
Features and benefits
Economical to purchase, own and install
●S-base socket compatibility enables easy retrofit into your existing metering infrastructure
●Self diagnostics and an auto ranging power supply reduces potential wiring errors and installation costs.
●A simple interface and standard configuration software get you up and running quickly
●Easily replace electro-mechanical meters with the accurate, solid state PowerLogic E5600
Schneider Electric 6- North American Operating Division
Supported S-Base meter socket form factors include:
Self-contained, class 200 in forms:
● 2S
● 12S
● 16S
Transformer rated, class 20 in forms:
● 9S
● 36S
● 45S
Features and benefitsFeatures and benefits
Schneider Electric 7- North American Operating Division
View system data through the easy-to-read LCD screen
●The meter displays measurement data in numeric values, potential indicators, nominal service voltage, service type, power quadrant status, energy flow and name plate data.
●An alternate display provides diagnostic information.
Features and benefits
Schneider Electric 8- North American Operating Division
High accuracy measurements
● Meets ANSI C12.20 accuracy standard, a nationally recognized sub-metering benchmark
● Eliminate bulk energy billing and allocate costs to suites, tenants and departments based on their actual use
● Use energy cost tracking and tenant billing to improve tenant retention and quality, meet regulatory requirements and increase property value
● Onboard memory of 128KB provides 82 days of logged data
Features and benefits
30% energy savingsin a building canreduce overalloperating costby 10%
Schneider Electric 9- North American Operating Division
Industry standard communications
● Standard Modbus serial protocol
eases billing software, energy
management and building
automation system integration
● Improve efficiency by eliminating
manual meter reading
● Enhance future expansion
possibilities and reduce the costs
associated with proprietary protocols
Features and benefits
Schneider Electric 10- North American Operating Division
Meter characteristics (front panel)
Anti-tamper (revenue) lock
LCD display screen
ANSI C12.18 Type II front panel optical
Schneider Electric 11- North American Operating Division
Meter characteristics (rear connections)
Input/output and Modbus RS485 cable
Voltage inputs
Current inputs C B A
Current outputs A B C
Schneider Electric 12- North American Operating Division
● Meter forms.● Self-contained class 200 in form 2S, 12S, and 16S● Transformer rated class 20 in form 9S, 36S, and 45S
● S-based socket meter.● Auto-ranging voltage inputs for direct connection of 120 - 480V● Supports 4-wire wye, 3-wire wye, 3-wire delta and single phase
● Starting Load:● Class 20: 0.005 amps● Class 200: 0.050 amps
● Power loss duration @ Vn – 100msec minimum.
● High Voltage Line Surges ANSI/IEEE C62 (6kV).
● Surge Withstand Capability (ANSI C37.90A).● Oscillatory: 3 kV ● Fast Transient: 5kV
Meter characteristics
Schneider Electric 13- North American Operating Division
● Overvoltage Withstand:● Temporary (0.5 seconds): 150% of rated voltage● Continuous (5 hours): 130% of rated voltage
● Smoked polycarbonate case.● Environmental.
● Operating temperature: -40 to 176 oF (-40 to 80 oC)● Humidity:5% to 95% non-condensing
● Communications.● RS485 serial interface with six foot interfacing cable – flying leads● ANSI C12.18 communications interface
● Utility Grade.● ANSI C12.20, class 0.2
● Security.● Multiple levels of security available via physical seals and passwords
Meter characteristics
Schneider Electric 14- North American Operating Division
PowerLogic software
A comprehensive range of cost effective, easy-to-use software for and end to end billing solution.
PowerLogic Tenant Metering - Commercial Edition
Real & reactive energy Flat & tiered rates Demand & power factor Seasonal rates Time of Use Miscellaneous charges
PowerLogic ION Setup Installation set up and meter
configuration software included with the PowerLogic E5600
PowerLogic ION Enterprise Scalable for system growth Integration with 3rd party meters,
equipment and web services Data sharing with BAS and business
systems Advanced power quality analysis,
reporting and control capabilities
PowerLogic System Manager Software
Real time readings Load profile upload Resets for date/time and demand Advanced power quality analysis,
reporting and control capabilities
Schneider Electric 15- North American Operating Division
Complete tenant metering solution
● Cost effective: ● Low cost of ownership enables placing meters wherever needed
● Easy installation:● Configuration and diagnostic tools simplify installation into existing utility
sockets utility
● Utility grade accuracy● Allocate cost and provide accurate tenant billing
● Power and energy readings: ● Achieve LEED and energy star certification
● Tenant Metering Commercial Edition Software: ● When combined with the PowerLogic E5600 completes the sub-billing
solution
● Support and services● Optimize your PowerLogic system with our technical expertise and
industry knowledge via the technical support, customer training or engineering services groups.
PowerLogic E5600 – the right meter for office, retail, campus, and government tenant metering applications
Schneider Electric 16- North American Operating Division
For more information, visit . . . PowerLogic.com