power system, rectifier

64
Complete Network Power Products for Business-Critical Continuity™ 2008 2009 Catalog

Upload: sunnguyen

Post on 01-Apr-2015

1.526 views

Category:

Documents


26 download

TRANSCRIPT

Page 1: Power System, Rectifier

Complete Network Power Productsfor Business-Critical Continuity™

2008~2009 Catalog

Page 2: Power System, Rectifier

3

1

7

7

9

11

9

8

1

44

6

5

2

2

5

1

Page 3: Power System, Rectifier

11010

8

9

6

6

6

11

3

No other organization can match the

scope of Emerson Network Power’s

product offerings and service

reach, nor provide such complete

grid-to-chip protection to ensure

Business-Critical Continuity™

for your technology

investment.

Grid-to-chip protection for your critical investments

Emerson Network Power supportsthese Centers of Expertise with thelargest global services organization in theindustry, delivering:

– Design, installation and startup

– Warranty service

– Preventive maintenance

– 24x7 remote monitoring

– Emergency service

– Site audits

Services

1

22

111

5

Page 4: Power System, Rectifier

DC POWER 1

AC POWER 23

RACKS & INTEGRATED CABINETS 41

PRECISION COOLING 43

MONITORING 48

EMBEDDED POWER 54

ContentsA Full Spectrum of Products of Emerson

Network Power

OUTSIDE PLANT 16

Page 5: Power System, Rectifier

Supporting voice and communications networks with

dependable DC power solutions. We’ve built on trusted

names-lorain®,Actura and PS-to create NetSure™

DCPower Solutions,the next-generation global technology

platform that delivers the most rigorous network-power

applications,with an unparalleled breadth DC power,

distribution,control and monitoring systems.

DC Power. Yet another way Emerson Network Power

enables Business-Critical Continuity™.

DC POWER

EMERSON NETWORK POWER.

THE GLOBAL LEADER IN ENABLING

BUSINESS-CRITICAL CONTINUITY.™

AC POWER

CONNECTIVITY

DC POWER

EMBEDDED COMPUTING

EMBEDDED POWER

MONITORING

OUTSIDE PLANT

POWER SWITCHING

& CONTROLS

PRECISION COOLING

RACKS & INTEGRATED

CABINETS

SERVICES

SURGE PROTECTION

1

Page 6: Power System, Rectifier

DC Power System

Confi guration MatrixLarge system Medium System Medium System Small System

NetSure 801 PS48600-3/2900-X5 PS48250-1A/2900 PS48250-1B/2900 PS48250-1C/2900 PS48165/3200

Max. Power 348kW 34.8kW 14.5kW 14.5kW 14.5kW 9.6kW

Voltage -48V -48V -48V -48V -48V -48V

Max. Current 6000A 600A 250A 250A 250A 165A

Max. Number of Rectifi ers 60 12 5 5 5 3

Rectifi er Type R48-5800 R48-2900 R48-2900 R48-2900 R48-2900 R48-3200,R48-2900

Controller Type M810G M500F M501D M501D M501D M501D

Dimension Multi-cabinet system 600×600×2000 600×600×2000 600×400×2000 600×400×700600×600×1600

or 584×327×132

Medium System Medium System Small System Small System Medium System

PS48360/1800 PS48300/1800-X6 PS48120/1800-X6 PS4875/25 PS24600/75 PSC48150/25

Max. Power 20.88kW 17.4kW 6.96kW 4.35kW 17.4kW 7.2kW

Voltage -48V -48V -48V -48V +24V -48V

Max. Current 360A 300A 120A 75A 600A 150A

Max. Number of Rectifi ers 12 10 4 3 8 6

Rectifi er Type R48-1800 R48-1800 R48-1800 HD4825-3 HD2475-2 C24/48-1200

Controller Type M501D M501D M501D PSM-A10 PSM-A11

Dimension 600×600×2000 600×600×1600 600×600×2000 450×260×700 600×600×2000 200×400×1460

2

DC Power System

Page 7: Power System, Rectifier

NetSure 801Stand-alone DC Power Series-48VDCup to 348kW

ApplicationsLarge and medium switching offi ce

Level-1 transmission backbone line

GSM mobile switching offi ce, mobile tandem exchange

CDMA mobile switching offi ce, mobile tandem exchange

DC Internet data center

System featuresSpace saving, 116kW(2000A@58V) capacity one cabinet

Capacity expandable up to 348kW(6000A@58V)

Three-phase rectifi ers (R48-5800) and SCU+(M810G) inside

Wide AC input range, 260V to 530Vac, up to 600Vac endurance without damage

System Effi ciency high up to 93%

Power factor high up to 0.99

Output current Walk-in available

Rectifi ers and controller hot swappable

Front access

Top or bottom cabling

Surge protection on AC, DC and signal side

Modularized design for system and function unit

TCP/IP, SNMP, web browser support

Rectifi er CE/UL approved

Compliance with EN60590 and EN300386, ROHS

Patented energy-saving mode

M810G

R48-5800

3

Business-Critical Continuity™

Page 8: Power System, Rectifier

DC distribution cabinet

FeaturesLocal large LCD display

Dual mains auto/manual switchover

Front access, Top / bottom cabling

DC emergency lighting available

Expandable up to f ive AC cabinets

Lightning proof and electric Compliance with IEC

ROHS Compatible

Affi liated CabinetAC distribution cabinet

AC distribution cabinet

FeaturesIndependent monitoring unit for decentralized supply

Local large LCD display

Front access, Top / bottom cabling

DC emergency lighting available

Expandable up to 8 DC cabinets

Lightning proof and electric Compliance with IEC

ROHS Compatible

DC distribution cabinet

4

DC Power System

Page 9: Power System, Rectifier

Dimensions And WeightCabinet Cabinet / module capacity W×D×H, mm Weight (kg)

Rectifier RackRack1000-6 Cabinet 1000A 600×600×2000 140(exclude rectifier)

Rack2000-6 Cabinet 2000A 600×600×2000 180(exclude rectifier)

AC Cabinet

PD380/400AFH-6/X1 400A 800×600×2000 240

PD380/630AFH-6/X1 630A 800×600×2000 240 Manual switchover

PD380/630AFA 630A 800×600×2000 250 Automatic switchover

DC CabinetPD48/1600DF-6/X1 1600A 800×600×2000 280

PD48/2500DF-6/X1 2500A 800×600×2000 290

DC High Ohmic

Distribution CabinetPD48/2000HF 2000A 800×600×2000 320

Integrated AC/DC

Distribution CabinetPD48/1200BFH 1200A 800×600×2000 320

Rectifier R48-5800 5800W 244×372×88 7.8

Controller M810G / 243.5×161×88 2

PD48/2000HF High Ohmic Power Distribution Cabinet

FeaturesUp to 120 branches high/low ohmic output

Local large LCD display

Front access

Lightning proof and electric Compliance with IEC

ROHS Compatible

PD48/1200BFHIntegrated AC/DC Distribution Cabinet

FeaturesAC.DC distribution unit in one cabinet

Space saving

Local large LCD display

Dual mains auto/manual switchover

Front access

Lightning proof and electric Compliance with IEC

ROHS Compatible

PD48/2000HF

PD48/1200BFH

Business-Critical Continuity™

Page 10: Power System, Rectifier

PS48600-3/2900-X5

M500F

R48-2900

PS48600-3/2900-X5Integrative DC Power Series-48VDCup to 34.8kW

Applications2G, 3G mobile base stations

Medium exchanges, rural telecom networks and access networks

Transmission relay stations

Microwave/satellite communications stations

Dimensions And Weightmodel W×D×H, mm Weight (kg)

Cabinet PS48600-3/2900-X5 600×600×2000 140(rectifi er excluded)

Rectifi er R48-2900 85.5×287×132.5 3.5

Controller M500F

FeaturesCapacity up to 34.8kW (600A @ 58V)

Rectifi ers R48-2900(2900W)and SCU inside

Wide input voltage range (85 to 290Vac), up to 415Vac endurance without damage

Effi ciency high up to 93%

Power factor high up to 0.99

Output current Walk-in available

Patented energy-saving mode available

Intelligent monitoring and remote control

Surge protection on AC, DC and signal side

Rectifi ers and controller hot swappable

Front access

Top or bottom cabling

Rectifi er CE/UL approval

Compliance with RoHS

6

DC Power System

Page 11: Power System, Rectifier

PS48250-1A/2900PS48250-1B/2900PS48250-1C/2900(ACTURA Flex 48330)Integrative DC Power Series-48VDCup to 14.5kW

Applications2G, 3G mobile base stations

Medium exchanges, rural telecom networks and access networks

Transmission relay stations

Microwave/satellite communications stations

PS48250-1A/2900

PS48250-1B/2900

PS48250-1C/2900Dimensions And Weightmodel W×D×H, mm Weight (kg)

Cabinet

PS48250-1A/2900 600×600×2000 135(rectifi er excluded)

PS48250-1B/2900 600×400×2000 125(rectifi er excluded)

PS48250-1C/2900 600×400×700 60 (rectifi er excluded)

Rectifi er R48-2900 85.5×287×132.5 3.5

Controller M500F

FeaturesCapacity up to 14.5kW (250A @ 58V)

Rectifi ers R48-2900(2900W)and SCU inside

Super fl exible confi guration

Wide input voltage range (85 to 290Vac), up to 415Vac endurance without damage

Effi ciency high up to 93%

Power factor high up to 0.99

Output current Walk-in available

Patented energy-saving mode available

Intelligent monitoring and remote control

Surge protection on AC, DC and signal side

Rectifi ers and controller hot swappable

Front access

Top cabling

Inner 660Ah battery shelves optional

Rectifi er CE/UL approval

Compliance with RoHS

7

Business-Critical Continuity™

Page 12: Power System, Rectifier

PS48165/3200

(ACTURA OPTIMA 48200)Integrative DC Power Series-48VDCup to 9.6kW

Applications2G, 3G mobile base stations

Medium exchanges, rural telecom networks and access networks

Transmission relay stations

Microwave/satellite communications stations

Dimensions And Weightmodel W×D×H, mm Weight (kg) Distribution Unit Location

CabinetPS48165/3200 mode 1 600×600×1600 75(rectifi er excluded) Top

PS48165/3200 mode 2 600×400×1600 65(rectifi er excluded) rear

Subrack PS48165/3200 mode 3 584×327×132 20(rectifi er excluded)

FeaturesCapacity up to 9.6kW (165A @ 58V)

Rectifi ers R48-3200(3200W)and SCU inside

Wide input voltage range (85 to 290Vac), up to 415Vac endurance without damage

Effi ciency high up to 93%

Power factor high up to 0.99

Output current Walk-in available

Patented energy-saving mode available

Intelligent monitoring and remote control

Surge protection on AC, DC and signal side

Rectifi ers and controller hot swappable

Top cabling

Inner dual battery shelves optional

Rectifi er CE/UL approval

Compliance with RoHS

PS48165/3200 mode1

PS48165/3200 mode2

PS48165/3200 mode3

8

DC Power System

Page 13: Power System, Rectifier

PS48360/1800

(ACTURA Flex 48420)Integrative DC Power Series-48VDCup to 20.8kW

Applications2G, 3G mobile base stations

Medium exchanges, rural telecom networks and access networks

Transmission relay stations

Microwave/satellite communications stations

PS48360/1800Dimensions And Weightmodel W×D×H, mm Weight (kg)

Cabinet

PS48360/1800-X1 600×600×2000 135(rectifier excluded)

PS48360/1800-X2 600×400×2000 125(rectifier excluded)

PS48360/1800-X3 600×600×1800 100(rectifier excluded)

FeaturesCapacity up to 20.8kW (360A @ 58V)

Rectifiers R48-1800(1740W)and SCU inside

Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage

Efficiency high up to 92%

Power factor high up to 0.99

Output current Walk-in available

Patented energy-saving mode available

Intelligent monitoring and remote control

Surge protection on AC, DC and signal side

Rectifiers and controller hot swappable

Front access

Top cabling

Inner 660Ah battery shelves optional

Rectifier CE/UL approval

Compliance with RoHS

R48-1800

M501D

Business-Critical Continuity™

Page 14: Power System, Rectifier

PS48300/1800-X6Integrative DC Power Series-48VDCup to 14.7kW

Applications2G, 3G mobile base stations

Medium exchanges, rural telecom networks and access networks

Transmission relay stations

Microwave/satellite communications stations

Dimensions And Weightmodel W×D×H, mm Weight (kg)

Cabinet PS48300/1800-X6 600×600×1600 130(rectifi er excluded)

FeaturesCapacity up to 14.7kW (300A @ 58V)

Rectifi ers R48-1800(1740W)and SCU inside

Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage

Effi ciency high up to 92%

Power factor high up to 0.99

Output current Walk-in available

Patented energy-saving mode available

Intelligent monitoring and remote control

Surge protection on AC, DC and signal side

Rectifi ers and controller hot swappable

Front access

Top/Bottom cabling

Rectifi er CE/UL approval

Compliance with RoHS

PS48300/1800-X6

M501D

R48-1800

10

DC Power System

Page 15: Power System, Rectifier

PS48120/1800-X6Integrative DC Power Series-48VDCup to 6.96kW

Applications2G, 3G mobile base stations

small exchanges, rural telecom networks and access networks

Transmission relay stations

Microwave/satellite communications stations

Railway stations

Dimensions And Weightmodel W×D×H, mm Weight (kg)

Cabinet PS48120/1800-X6 600×600×2000 110(rectifi er excluded)

FeaturesCapacity up to 6.96kW (120A @ 58V)

Rectifi ers R48-1800(1740W)and SCU inside

Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage

Effi ciency high up to 92%

Power factor high up to 0.99

Output current Walk-in available

Patented energy-saving mode available

Intelligent monitoring and remote control

Surge protection on AC, DC and signal side

Rectifi ers and controller hot swappable

Front access

Top/Bottom cabling

Inner 330Ah battery shelves optional

Rectifi er CE/UL approval

Compliance with RoHS

PS48120/1800-X6

M501D

R48-1800

11

Business-Critical Continuity™

Page 16: Power System, Rectifier

PS4875/25Wall-mounted Integrative DC Power Series-48VDCup to 4.35kW

Applications2G, 3G mobile base stations

Small exchanges, rural telecom networks and access networks

Transmission relay stations

Microwave/satellite communications stations

Railway stations

Dimensions And Weightmodel W×D×H, mm Weight (kg)

Cabinet PS4875/25 450×260×700 40(rectifi er excluded)

FeaturesCapacity up to 4.35kW (75A @ 58V)

Rectifi ers HD4825-3(1450W)inside

Wall-mounted for space saving

Wide input voltage range (90 to 290Vac), up to 415Vac endurance without damage

Effi ciency high up to 90%

Power factor high up to 0.99

Output current Walk-in available

Patented energy-saving mode available

Intelligent monitoring and remote control

Surge protection on AC, DC and signal side

Rectifi ers and controller hot swappable

Front access

Top cabling

Rectifi er CE approval

Compliance with RoHS

PS4875/25

12

DC Power System

Page 17: Power System, Rectifier

PS4890/800 (ACTURA 48201)Subrack DC Power Series-48VDCup to 4.8kW

Applications2G, 3G mobile base stations

small access networks

Microwave/satellite communications stations

Dimensions And Weightmodel W×D×H, mm Weight (kg)

PS4890/800 single subrack 485×345×90 8.8(rectifi er excluded)

PS4890/800 dual subracks 485×345×180 17.9(rectifi er excluded)

Features19” Subrack system

Capacity up to 2.4kW one subrack, 4.8kW dual subracks

Rectifi ers R48-800(800W)and SCU inside

Wide input voltage range (85 to 300Vac)

Effi ciency high up to 91%

Power factor high up to 0.99

Output current Walk-in available

Patented energy-saving mode available

Intelligent monitoring and remote control

BLVD, LLVD optional

Rectifi ers and controller hot swappable

Rectifi er CE/UL approval

Compliance with RoHS

13

Business-Critical Continuity™

Page 18: Power System, Rectifier

Applications2G, 3G mobile base stations

Medium exchanges, rural telecom networks and access networks

Transmission relay stations

Microwave/satellite communications stations

PS24600/75Integrative DC Power Series+24VDCup to 17.4kW

Dimensions And Weight model W×D×H, mm Weight (kg)

Cabinet PS48600-3/2900-X5 600×600×2000 158(rectifi er excluded)

Rectifi er HD2475-2 105×400×245 8

Controller PSM-A11

Key FeaturesCapacity up to 17.4kW (600A @29V)

Rectifi ers HD2475-2(2175W)inside

Wide input voltage range (120 to 290Vac), up to 415Vac endurance without damage

Effi ciency high up to 88%

Power factor high up to 0.99

Intelligent monitoring and remote control

Surge protection on AC, DC and signal side

Rectifi ers and controller hot swappable

Front access

Top or bottom cabling

Rectifi er CE approval

Compliance with RoHS

PS24600/75

14

DC Power System

Page 19: Power System, Rectifier

PSC48150/25Integrative DC Power Series+24Vdc/-48Vdc, 7.2kW

Applications2G, 3G mobile base stations

Medium exchanges

Transmission relay stations

Microwave/satellite communications stations

Dimensions And Weightmodel W×D×H, mm Weight (kg)

Cabinet PSC48150/25 200×400×1460 45(rectifi er excluded)

DC/DC converter C24/48-1200 85.5×287×132.5 2.5

Features+24V/-48V DC/DC system

Capacity up to 7.2kW

Wide DC input voltage range: 21V~29V

DC/DC module(1200W)inside

DC/DC converter Hot-swappable

Extremely low radiation, meeting

Relay output for alarm port

Complete lightning proof in input and output rated at 5KA(8/20us)

Complete fault protection functions

Optional remote monitor and control

Front access

Compliance with RoHS

PSC48150/25

1�

Business-Critical Continuity™

Page 20: Power System, Rectifier

OUTSIDE PLANT

EMERSON NETWORK POWER.

THE GLOBAL LEADER IN ENABLING

BUSINESS-CRITICAL CONTINUITY.™

AC POWER

CONNECTIVITY

DC POWER

EMBEDDED COMPUTING

EMBEDDED POWER

MONITORING

OUTSIDE PLANT

POWER SWITCHING

& CONTROLS

PRECISION COOLING

RACKS & INTEGRATED

CABINETS

SERVICES

SURGE PROTECTION

Protecting and moving voice,video and data from the

central offi ce closer to the subscriber. We deliver a full line of

enclosures,cabinets and shelters that meet the networked

world’s demands for high speed without interruption,

from MESA® and DEC integrated enclosure solutions to

Emerson Network Power ES, EC, EPC outdoor power solutions

to cross-connects to ProFORM® distribution terminals to

NetSpanTM Integrated FTTx Solutions.

OUTSIDE PLANT. Yet another way Emerson Network power

enables Business-Critical Continuity™.

16

Page 21: Power System, Rectifier

EPC48180/1800-FA-48VDC Outdoor Power Cabinet

Dimensions And Weightmodel W×D×H, mm Weight (kg)

Cabinet EPC48180/1800-FA 700×700×1700 150(rectifiers and batteries excluded)

FeaturesCapacity up to 10.44kW (180A @ 58V)

Totally front access in favor of space-saving

Forced vent cooling system

Patent design of Isolated air channel for safe operation

IP55 for equipment chamber

Forced vent cooling for battery chambers

Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage

Rectifiers R48-1800(1740W) and SCU inside

Efficiency high up to 92%

Power factor high up to 0.99

Output current Walk-in available

Perfect fan speed control for energy-saving

Patent energy-saving mode available

Intelligent monitoring and remote control

Surge protection on AC, DC and signal side

Class B+C lightning protection optional

Rectifiers and controller hot swappable

Inner dual 330Ah battery Chambers

Rectifier CE/UL approval

Compliance with EN60950 and IEC60950, RoHS

H-mast platform installation available

ApplicationsOutdoor stations of GSM, UMTS, CDMA

Fiber optic transmission systems

Digital loop carriers

EPC48180/1800-FA

17

Business-Critical Continuity™

Page 22: Power System, Rectifier

EPC48120/1800-F-48VDC Outdoor Power Cabinet

Dimensions And Weightmodel W×D×H, mm Weight (kg)

Cabinet EPC48120/1800-F 600×630×1500 140(rectifi ers and batteries excluded)

FeaturesCapacity up to 6.96kW (120A @ 58V)

Totally front access in favor of space-saving

Forced vent cooling system

IP45 for equipment chamber

Patent design of Isolated air channel for safe operation

Forced vent cooling for battery chambers

Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage

Rectifi ers R48-1800(1740W)and SCU inside

Effi ciency high up to 92%

Power factor high up to 0.99

Output current Walk-in available

Perfect fan speed control for energy-saving

Patent energy-saving mode available

Intelligent monitoring and remote control

Surge protection on AC, DC and signal side

Class B+C lightning protection optional

Rectifi ers and controller hot swappable

Inner dual 330Ah battery Chambers

Rectifi er CE/UL approval

Compliance with EN60950 and IEC60950, RoHS

H-mast platform installation available

ApplicationsOutdoor stations of GSM, UMTS, CDMA

Fiber optic transmission systems

Digital loop carriers

EPC48120/1800-F

18

Outside Plant

Page 23: Power System, Rectifier

EPC48120/1800-HA(B)-48VDC Outdoor Power Cabinet

Dimensions And Weightmodel Op. temp. W×D×H, mm Weight (kg)

CabinetEPC48120/1800-HA -10~+45℃

600×600×1700 150(rectifiers and batteries excluded)EPC48120/1800-HB -40~+45℃

FeaturesCapacity up to 6.96kW (120A @ 58V)

Totally front access in favor of space-saving

Heat-exchange cooling system

IP55 for equipment chamber

Wide operation temperature, -40~+45℃ optional

Patent design of Isolated air channel for safe operation

Forced vent cooling for battery chambers

Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage

Rectifiers R48-1800(1740W)and SCU inside

Efficiency high up to 92%

Power factor high up to 0.99

Output current Walk-in available

Perfect fan speed control for energy-saving

Patent energy-saving mode available

Intelligent monitoring and remote control

Surge protection on AC, DC and signal side

Class B+C lightning protection optional

Rectifiers and controller hot swappable

Inner dual 330Ah battery Chambers

Rectifier CE/UL approval

CE mark

Compliance with EN60950 and IEC60950, RoHS

H-mast platform installation available

ApplicationsOutdoor stations of GSM, UMTS, CDMA

Fiber optic transmission systems

Digital loop carriers

EPC48120/1800-HA

EPC48120/1800-HB

19

Business-Critical Continuity™

Page 24: Power System, Rectifier

EC200T/01Outdoor Battery Cabinet

Dimensions And Weightmodel Op. temp. W×D×H, mm Weight (kg)

Cabinet EC150F/01 -10~+55℃ 650×720×1400 100(batteries excluded)

FeaturesCater up to 3 strings of 165Ah batteries

Thermoelectricity cooler (TEC) inside

Inner temperature 5~15℃ below outside ambient

IP55

Dry-contact alarm for fans and door sensor

Compliance with RoHS

ApplicationsOutdoor stations of GSM, UMTS, CDMA

Fiber optic transmission systems

Digital loop carriers

EC200T/01

20

Outside Plant

Page 25: Power System, Rectifier

EC150F/01

EC150F/01Outdoor Battery Cabinet

Dimensions And Weightmodel Op. temp. W×D×H, mm Weight (kg)

Cabinet EC150F/01 -10~+45℃ 700×700×1000 100(batteries excluded)

FeaturesCater up to 2 strings of 165Ah batteries

Forced vent cooling

IP34

Dry-contact alarm for fans and door sensor

Compliance with RoHS

ApplicationsOutdoor stations of GSM, UMTS, CDMA

Fiber optic transmission systems

Digital loop carriers

21

Business-Critical Continuity™

Page 26: Power System, Rectifier

EC100F/01Outdoor Battery Cabinet

Dimensions And Weightmodel Op. temp. W×D×H, mm Weight (kg)

Cabinet EC100F/01 -10~+45℃ 600×600×1000 100(batteries excluded)

FeaturesCater up to 2 strings of 165Ah batteries

Forced vent cooling

IP34

Dry-contact alarm for fans and door sensor

Compliance with RoHS

ApplicationsOutdoor stations of GSM, UMTS, CDMA

Fiber optic transmission systems

Digital loop carriers

EC100F/01

22

Outside Plant

Page 27: Power System, Rectifier

Sustaining critical operations that simply can’t

go down. We deliver a full range of uninterruptible

Liebert® AC power systems and complete

associated power distribution and enclosures,

from individual products to integrated systems

that keep network closets up and running.

AC Power. Yet another way Emerson Network

Power enables Business-Critical Continuity™.

AC POWER

EMERSON NETWORK POWER.

THE GLOBAL LEADER IN ENABLING

BUSINESS-CRITICAL CONTINUITY.™

AC POWER

CONNECTIVITY

DC POWER

EMBEDDED COMPUTING

EMBEDDED POWER

MONITORING

OUTSIDE PLANT

POWER SWITCHING

& CONTROLS

PRECISION COOLING

RACKS & INTEGRATED

CABINETS

SERVICES

SURGE PROTECTION

23

Page 28: Power System, Rectifier

24

AC Power

AC POWER

Confi guration MatrixSmall System Medium System Small System

SERIES: US11R iTrust 31 iTrust 2G

RATING: 1/2/3KVA 10/15/20KVA 3/6/9/12/15/18KVA

MOUNTING: Tower/Rack Tower Tower/Rack

I/O: 1-ph./1-ph. 3-ph./1-ph. 1-ph./1-ph.

VOLTAGE: 220/230/240 (L-N) 380/220 220 (L-N)

FREQUENCY: 50Hz 50Hz 50Hz

Large system Medium System

SERIES: NX Hipulse-U Outdoor UPS

RATING: 10/15/20/30/40/60/80/100/120/140/160/200KVA 160/200/300/400KVA 2KVA/3KVA

MOUNTING: Tower Tower Tower

I/O: 3-ph./3-Ph. 3-ph./3-ph. 1-ph./1-ph.

VOLTAGE: 380/400/415 (L-L) 380/400/415 (L-L) 220(L-N)

FREQUENCY: 50/60Hz 50/60Hz 50Hz

Page 29: Power System, Rectifier

US11-R Series——1/2/3KVA

Special FeaturesRack/Tower design, adaptable for table and 19' IT rack application

Double conversion, true on-line style

Fully digital control

Input surge suppressor equipped

CE marked

IGBT based rectifier and excellent input performance

Super wide input window

Mutiple AC output connections

2U height

High EMC performance, classB achieved

Intelligent battery management

Dimensions And WeightModel Name Size(WDH in MM) Weight(Kg)

US11R-0010 440×400×87 17.5

US11R-0010L 440×400×87 7.8

US11R-0020 440×400×87 29.1

US11R-0020L 440×400×87 9.6

US11R-0030 440×400×87 30.5

US11R-0030L 440×400×87 10.5

UF-B0007-06 440×400×87 20.5

UF-B0009-06 440×400×87 21.5

Note: US11R-0020 will be shipped with a VF-B0007-06 US11R-0023 will be shipped with a VF-B0009-06

25

Business-Critical Continuity™

ApplicationsServers/Storage/Workstation

Telecommunication, VoIP

Small Office Network

Data Warehouses

Medical Diagnostics

Process Automation Equipmentsv

Page 30: Power System, Rectifier

US11-R Series Datasheet

ModelUS11R-0010 US11R-0020 US11R-0030

US11R-0010L US11R-0020L US11R-0030L

Nominal Power Rating at 0.7 PF 1KVA 2KVA 3KVA

Input Parameters

Rectifi er Type IGBT-based PFC(Power Factor Correction)

Input Voltage 220Vac, 1-ph, 3-w

Permissible Input Voltage Range 120-288Vac

Permissible Input Frequency Range 50Hz ±2%,5%,7%,10% User selectable

Input Power Factor at nominal voltage ≥0.99

Battery

Battery Type Maintenace Free, VRLA (Valve Regulated Lead Acid)

Nominal Battery Bus 36Vdc 72Vdc 72Vdc

Recharging Time to 90% Recovery <4 hours <4 hours <4 hours

Output Parameters

Inverter Type IGBT-based Inverter

Output Power 0.7kW 1.4kW 2.1kW

Output Connection GB/IEC GB/IEC GB/IEC/Terminal

Output Voltage 220Vac, 1-ph, 3-w

Output Frequency 50Hz ±0.2%

Output Voltage THD <3% at linear load; < 5% at non-linear load

Capability to handle High Crest Factor Load 3:1 (compliant with IEC 62040-3)

Capability to handle Step Load 100%

Overload Capability

105% FL Infi nite

105-125% FL for 5 mins

125-150% FL for 1min

>150% FL for 10s

System Parameters & Standards

AC-AC Effi ciency >89% >90% >90%

Switch Time When Input Fails 0s

Noise <43dB <45dB

Display LED

Dimension (W×D×H)mm 440×400×87

U-Height 2u 2u 2u

Weight (Standard/L model) 17.5/7.8kg 29.1/9.6 30.5/10kg

Safety EN62040-1-1, CE Marked

EMI /EMC EN50091-2 Class B

Inmunity EN50082-1

Surge Protection IEC 60664-1 Level IV

Protection IP21

Communication & Management

Interface Port Serial / Dry Contact / SNMP Card

Web/SNMP Card Optional

Environmental Parameters

Operating Temperature Range 0℃ to 40℃ (UPS) & 25℃ ±5 (Battery)

Relative Humidity 0% to 95% (non-condensing)

Maximum Altitude above MSL 1500m (as per IEC 62040-3)

26

AC Power

Page 31: Power System, Rectifier

UH31 Series—10/15/20KVA

ApplicationsSmall data centers of banks/stock exchanges, server groups, small/middle computer rooms,

offices, PC groups, important facilities, etc

FeaturesThree phases input, one phase output ( 220/230Vac)

True on-line style

IGBT based rectifier/inverter

DSP control

Super wide input window (-45%~+15%)

On-line operation when input phases lose

D-class surge suppressor equipped

Intelligent battery management

Chinese/English LCD interface available

Class A EMC standard acquired

Input phase loss tolerance

Dimensions And WeightModel Name Size(WDH in MM) Weight(Kg)

UH31-0100L 280×875×770 97

UH31-0150L 280×875×770 97

UH31-0200L 280×875×770 116

27

Business-Critical Continuity™

Page 32: Power System, Rectifier

Model UH31-0100L UH31L-0150 UH31-0200L

Nominal Power Rating at 0.7 PF 10KVA 15KVA 20KVA

Input Parameters

Rectifi er Type IGBT-based PFC (PF Corrected)

Input Voltage 380Vac, 3-ph, 4-w

Permissible Input Voltage Range 120Vac-276Vac

Permissible Input Frequency Range 45-55Hz

Input Power Factor at nominal voltage ≥0.95

Battery

Battery Type VRLA (Value Regulated Lead Acid)

Nominal Battery Bus 480Vdc 480Vdc 480Vdc

Output Parameters

Inverter Type IGBT-based Inverter

Output Power 7kW 10.5kW 14kW

Bypass Voltage Range 120Vac-253Vac

Output Voltage 220Vac, 1-ph, 3-w

Output Voltage Regulation ±0.5%

Output Frequency 50Hz

Output Voltage THD < 3% at linear load; < 5% at non-linear load

Capability to handle High Crest 3:1 (compliant with IEC 62040-3)

Factor Load

Capability to handle Step Load 100%

Overload Capability

105-125% FL for 10 mins

125-150% FL for 1min

>150% FL for 200ms

System Parameters &Standards

AC-AC Effi ciency >91% >92%

Switch Time When Input Fails 0s

Noise <55dB <60dB

Display LED+LCD

Dimension (W×D×H) 280×875×770mm

Weight (Standard/L model) 97kg 116kg

Safety EN60950

Immunity EN61000-4-2,3,4,6,8,11 Level III, EN61000-4-5 Level IV

EMC EN55022 Class A

Surge Protection IEC 60664-1 Level IV

Parameters &Standards

Operating Temperature Range 0℃ to 40℃ (UPS) & 25℃ ±5℃ (Battery)

Relative Humidity 0% to 95% (non-condensing)

Maximum Altitude above MSL 1500m (as per IEC 62040-3)

UH31 Series Datasheet

28

AC Power

Page 33: Power System, Rectifier

iTrust 2G Series UPS

ApplicationsIndustrial equipments

Small data centers

Computing centers

Telecommunication network hubs

FeaturesModular Design- Plug & Play

N+X Redundancy - Higher reliability

Easy and cheap expansion- Modules only

Online during maintenance- By simply replacing modules

Space saving - Compact Design

Large Capacity Battery Affordable -Extendable 10A/20A charger available

Energy Saving - High Efficiency and excellent input PF

Higher adaptability to harsh input - Extremely Wide Input window

Longer battery life available - Intelligent Battery Management

Quiet - Low noise

Less worry - Self diagnosis and Fault Prediction

Dimensions And WeightModel Name Size(WDH in MM) Weight(Kg)

Power Module UF-P0030 436 × 412 × 85 10.4

Battery Module UF-B0007-8 436 × 400 × 36 26

10A Charger Module UFP-BCH110/10 436 × 412 × 85 7.6

20A Charger Module UFP-BCH110/20 436 × 412 × 85 10.4

6-Bay Rack UP11-0180/6 500 × 552 × 994 70

12-Bay Rack UP11-0180/12 500 × 552 × 1492 105

29

Business-Critical Continuity™

Page 34: Power System, Rectifier

Models 3KVA 6KVA 9KVA 12KVA 15KVA 18KVA

2.4kW 4.8kW 7.2kW 9.6kW 12kW 14.4kW

Model Name UP11-0180/12(12-Bay) UP11-0180/6(6-Bay)

Input Parameters

Rectifi er Type IGBT-based PFC

Input Voltage 220Vac/1ph/3w

Permissible Input Voltage Range 120-288Vac

Permissible Input Frequency Range 45-55Hz

Input Power Factor at nominal voltage ≥0.99 without any Filter

Ace

Battery

Battery Type VRLA

Nominal Battery Bus 96Vdc

Output Parameters

Inverter Type IGBT-based

Output Rating 3/6/9/12/15/18 KVA

Output Power Factor 0.8

Output Voltage 220Vac/1ph/3w

Output Voltage Regulation 1%

Output Frequency 50Hz

Capability to handle High Crest Factor Load 3:1

Capability to handle Step Load 100%

Compliance to EMC Class-A Applicable for both Radiated & Conducted

Overload Capability

105% FL for continuous running

125% FL for 10 minutes

150% FL for 10 S

System Performance

AC-AC Effi ciency > 90%

Transfer Time When Input Fail 0s

Environmental Parameters

Operating Temperature Range 0℃to 40℃ (UPS)

Relative Humidity 0% to 95% (non-condensing)

Maximum Altitude above MSL 1500m (as per IEC 62040 3)

Physical Parameters &Standards

Colour Black

Degree of Protection IP21

iTrust 2G Series Datasheet

30

AC Power

Page 35: Power System, Rectifier

NX Series UPS

FeaturesFull digital control based on latest DSP

Advanced Vector Control to Achieve Excellent Output Performance

'Green UPS' Design with High input power factor : 0.99 Low input current harmonic of less than : 3%

Wide input window : 208-477V (L-L voltage)

Parallel up to 6 units, No MSS needed

High Efficiency: up to 94%

Compact Footorint and Front Access

Unique Dual Bus design

Flexible Power Walk-in

Built-in Redundancies to Achieve High Reliability(fans/auxiliary power supply card/..)

Intelligent battery management

Self diagnosis

Dimensions And WeightModel Name Size(WDH in MM) Weight(Kg)

NXe-10KVA 600×700×1400 180

NXe-15KVA 600×700×1400 204

NXe-20KVA 600×700×1400 204

NXe-30KVA 600×700×1400 260

NXa-40KVA 600×825×1600 340

NXa-60KVA 600×825×1600 400

NXa-80KVA 600×825×1600 445

NXa-100KVA 700×825×1800 720

NXa-120KVA 700×825×1800 720

NXa-140KVA 1000×825×1800 824

NXa-160KVA 1000×825×1800 973

NXa-200KVA 1000×825×1800 973

ApplicationsServer Rooms and Mid-sized Data Centers

Telecommunication (Fixed, WiLL & Mobile) Billing Computers

Networks (LAN, MAN & WAN), InfoCom and WiFi Hot Spots

Industrial Process & Motion Automations for Mid-sized Plants

Medical Diagnostic / Imaging Equipment

31

Business-Critical Continuity™

Page 36: Power System, Rectifier

NX Series DatasheetModels Nxe 10 Nxe 15 Nxe 20 Nxa 30 Nxa 40 Nxa 60 Nxa 80 Nxa 100 Nxa 120 Nxa 140 Nxa 160 Nxa 200

Nominal Power Rating at 0.8 PF 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 140KVA 160KVA 200KVA

Input Parameters

Rectifi er Type IGBT-based Vector Controlled PFC (PF Corrected)

Input Voltage 380/400/415Vac (Accepted from 305-477Vac without Batt. Use)

Input Frequency 40-70Hz

Input Current THD <3% (without any Filter)

Input Power Factor ≥0.99 (without any Filter)

Flexi Power Walk-In 5 to 30S (Selectable)

Battery

Battery Type VRLA (Value Regulated Lead Acid) / Wet-Flooded / NiCd

End-Cell Voltage Selectable from 1.60-1.90Vdc/Cell (VRLA)

DC ripple Current in fl oat

mode<5%(C10 AH Capacity) RMS Value

DC ripple Voltage in

fl oat & Const V Ch.mode<1% (RMS Value)

Temperature

Compensated Battery

Charging

Standard (for in-build batteries for 10/15/20/30/40 KVA)

Optional (for all other battery confi gurations)

In-Built VRLA Battery

AvailabilityOptionally applicable for 10/15/20/30/40 KVA

Output Parameters

Inverter Type IGBT-based Vector, Repetitive & PI Controlled

Output Power 8kW 12kW 16kW 24kW 32kW 48kW 64kW 80kW 96kW 112kW 128kW 160kW

Output Voltage 380/400/415Vac * (Nominal: 400V) 3-ph, 4-w (Ph+N)

Output Voltage

Regulation±0.5%

Output Frequency 50/60±0.05Hz Regulation

Output Voltage THD 1% (max)

Max. Crest Factor Load 3:1 (compliant with IEC 62040-3)

Capability to handle

Step Load100%

Max. Leading PF Load Up to 0.9

Voltage Displacement 120o±1oel (with 100% unbalanced load)

Overload Capability 110 for 60 minutes, 125 for 10 minutes, 150 for 1 minutes

Standards

EMC Class Class A (Applicable for both Radiated & Conducted)

Enclosure IP IP 20 even with front door in opened condition, IP21 Optional

Standards &

Conformities

IEC 62040-3, IEC 62040-2, IEC 62040-1-1, IEC 60146-1-1, IEC 61000-4-2,4,5,6,8,11, EN 50091-1-1,

EN 50091-2, EN 50091-3, EN60950, EN 60529, ANSI C62.41 (IEEE 587)

Environmental Parameters

Operating Temperature

Range0 to 40℃ (UPS) & 25 ±5℃ (Battery)

Relative Humidity 0 to 95% (non-condensing)

Maximum Altitude

above MSL1000m (as per IEC 62040-3)

32

AC Power

Page 37: Power System, Rectifier

Hipulse-U Series—160/200/300/400KVA

FeaturesFully Digital, Twin DSP controlled.

Rated at 0.9 output power factor to deliner more real power

Handle Leading Power factor Loads withour KW de-rating under specified conditions

On-Line Double Conversion

IGBT-based PWM Inverter

Wide input voltage tolerance(+15/15%)

Wide input frequency tolerance(45Hz-65Hz)

High overload capability of static bypass(14 times for 10 milliseconds and 10 times for 100

nukkusecibds)

Built-in maintenance bypass(Single and 1+N Models)

Wrap-around maintenance bypass(optional)

Front acces for spares replacement and preventive maintenance

Easy Dual bus Configuration architecture

Adjustable frequency synchronisation window up to 9% in the static bypass

Provision of automatic battery circuit breaker instead of using conventional isolator in the DC path

Field protocols ModBus/Jbus

Eady Scalability (Parallel 1+N configuration up to 6 modules paralleling)without centralised Main

Static Switch (MSS)

Bypass Switch

Compact footorint

ApplicationsMedinm & large Data Center

Telecommunication

Industrial Automation

Transport Automation

Banking, Insurance and Financial Sernices

Software Development Houses/Software Technology Parks(STP)

Building Automation

Medical Diagnostics

Satellite

Dimensions And WeightModel Name Size(WDH in MM) Weight(Kg)

Hipusle U-160KVA, 6 Pulse 1250×840×1910 1200

Hipusle U-160KVA, 12 Pulse 1640×840×1910 1725

Hipusle U-200KVA, 6 Pulse 1250×840×1910 1350

Hipusle U-200KVA, 12 Pulse 1640×840×1910 2000

Hipusle U-300KVA, 6 Pulse 1640×840×1910 1600

Hipusle U-300KVA, 12 Pulse 2280×840×1910 2200

Hipusle U-400KVA, 6 Pulse 2280×840×1910 2100

Hipusle U-400KVA, 12 Pulse 2280×840×1910 2750

33

Business-Critical Continuity™

Page 38: Power System, Rectifier

Hipulse-U Series DatasheetHipulse UPS System

Nominal Rating(KVA)(0.9pf)/kW 160/144 200/180 300/270 400/360

Rectifi er Type 6P 12P 6P 12P 6P 12P 6P 12P

Input

Voltage 380/400/415V(+/-15%)-3Ph-4w(rectifi er:290-498V)

Frequency 50 or 60Hz +/-5%

ITHD 4 to 9% with optional harmonic fi lter

Power Factor 0.90-0.95 with optional harmonic fi lter

Output

Voltage 380/400/415V-3Ph-4w

Voltage stability

-Steady state +/-0.5%

-100% Load Step +/3%

Frequency 50 or 60Hz

Frequency Stability

-Synchronised with the bypass supply +/0.5 Hz, +/-1 Hz, +/-2Hz, +/-3Hz(settable)

-Auto-Synchronised +/0.1%

Overload copacity from inverter at vominal voltage

-3 Ph 110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute

-1 Ph 200% for 30 seconds

short circuit current from inverter

-3 Ph 1.5 in for 5 seconds (in acordance with EN 50091-1-1)

-1 Ph 2.9 in for 5 seconds 2.2 in for 5 seconds

Voltage Distortion with Linear Load <3%

Voltage Distortion with 100%

Non-Linear Load<5%

Max.Deliverable Power

with Non-Linear Load(CF-3:1)100%

Max Unbalanced Load 100%

Voltage Displacement With

100% Unbalanced Load120o+/-1oel

Output Voltage Dissymmetry

with 100% Unbalanced Load2%

Standards and Approvals

Safety / EMC / Design IEC60950-1,IEC62040-1-1,UL1778,IEC62040-2 CLASS A,EN50091-CLASS A,IEC62040-3

European Directives

73/23/EEC and 89/336/EEC CE

34

AC Power

Page 39: Power System, Rectifier

Outdoor Series

Special FeaturesNatural cooling, high system reliability achieved

Dual conversion, online style

Fully digital control

Auto start up when mains recovered

Super wide input window (150-310V L-N)

IP55 protection level

Wide operation Temperature: -40-550C

High level surge suppressor can be equipped inside; (Optional)

Boosted/float charging auto transfer

3 mounting options available (wall/mask/floor)

Zero output interrupt when input fails

Optional charger for quick battery recovery in long backup system

Heater optional for cold area

Optional Battery cabinet available with maximum 4 hours backup time at full load

Power module separate with battery enclosure, high system flexibility achieved

Dimensions And WeightModel Name Size(WDH in MM) Weight(Kg)

Outdoor 2KVA UPS UH11-0020LC 485×263×615 53*

Outdoor 3KVA UPS UH11-0030LC 485×263×615 59**

Battery Cabinet (South Type) U6-100C3S 850×550×1170 70

Battery Cabinet (North Type) U6-100C3N 850×550×1170 72

*: Including Mounting Kit,36Kg Net

**: Including Mounting Kit,42Kg Net

ApplicationOutdoor BTS

35

Business-Critical Continuity™

Page 40: Power System, Rectifier

Outdoor Series DatasheetCapacity 2KVA/3KVA

Model Name UH11-0020LC, UH11-0030LC

Input

Rated Voltage 220Vac

Voltage Range 150-310Vac

Frequency 45~65Hz

Power Factor > 0.98

Output

Powe Factor 0.7 temp<5℃ 0.6 temp>10℃Normal Voltage 220Vac 3%

Frequency 50Hz

Frequency Tracking Rate ≤1 Hz/s

Inverter Overload Capability 105%-125%, 5mins, >125%, 20s,

Peak Factor 3:1

Bypass Voltage 150~310Vac

Effi ciency (NormalMode) >89%

Sheft Time

Utility Failure 0ms

Shift between invertermode and < 10ms

bypass mode (Synchronized )

Insulation

Insulation Resistance >2MΩ(500Vdc)

Dielectric Strength (Output to earth Input to earth)2820Vdc,leakage current <3.5mA for 1min without arc or

breakdown

Environment

Operation temperature -40℃ -55℃Storage temperature -40℃ -70℃relative humidity 10%-100% (no condensing)

altitude Under 4000m, over 4000m, de-rated,

Protection Level IP55

Noise <40dB

36

AC Power

Page 41: Power System, Rectifier

Monitoring Solutions

FeaturesJava programming language. Web-based general-purpose monitoring software

Compatible with multi operation systems, eg., Windows, Linux, Solaris, AIX, HP-UX, etc.

Can log on via any computer on network

UPS by-layer management mode

Complete history records for inquiry, statistics and preview before printing

Multi alarming: Sound, paging, email and messages, etc.

Multi language versions, on-line upload and upgrade

WEB-configured interfaces, very easy to operate

Large storage of history records

Least system resource occupied

Strict safety management mechanism

On-line smooth access system for new equipment

Multi system environment measures accessible

Our Monitoring Solution Includes 5 Parts

1.Point-to-point and internet-based network remote monitoring, unlimited with the number of

nodes

2.SNMP Card: An internet node, providing UPS with Ethernet communication capability

3.UPS Network Adapter: Monitoring UPS products of other brands

4.UPS Adapter for Equipment Room Signals Applied together with our SNMP Card, realizing

centralized monitoring and processing of multi environment measures such as temperature,

humidity, infrared, door alarm, water immersion ( 8 analogues and 8 dry contacts)

5.Wireless MODEM: Able to send wireless messages, reporting UPS operation status and alarms to

the customers and realizing No-Man-On-Duty

37

Business-Critical Continuity™

Page 42: Power System, Rectifier

SiteMonitor

Click on UPS icons to check all operation

indices and historical records online, with

power status completely in hand

Can name based on requirements and

display by layer

2. Clear display of UPS operation status

1. Easy installation

3. Easy setting and adjustment

U n d e r a u t h o r i z a t i o n , a n e t w o r k

administrator can remotely control the

center, eg. operate turnoff, battery self-

diagonosis, erase after sound alarm, etc.

Model selection and confi guration

38

AC Power

Page 43: Power System, Rectifier

SNMP Card-A Bridge Connecting

UPS and NetworkThe SNMP card is based on TCP/IP communication protocol and can also

support SNMP, HTTP(web server), Telnet communication protocols to meet the

needs of all sorts of networks

FeaturesSupports web browse and NMS management systems

Software can be updated on line

10/100M network self-adapting

Hot plug-in/plug-out supported

All the settings can be done through software

39

Business-Critical Continuity™

Page 44: Power System, Rectifier

Auto-adaptable on EOD(End Of Discharge) Adjustment

Different discharging solution for short backup-time system (<1h) and long backup-time

system(>1h)

The data of different models of batteries are stored in DSP and the UPS will detect the discharging

current and automatically adjust the EOD for best performance of the battery. In this way, over-

discharge of battery is avoided

Self-diagnosis

Battery self-diagnosis can be set to operate periodically via front panel

Auto-switch between Boost and Float Recharging

Shorten recharging period and prolong the battery life by 50%

Temperature Compensation

Auto-adjustment for fl oat charging voltage according to ambient temperature

Intelligent Battery Management

40

AC Power

Page 45: Power System, Rectifier

Optimizing technology and performance needs

for the global IT and telecom markets. We deliver

standard and customized integrated cabinet

solutions that meet unique and specifi c needs,

from knürr and Liebert® rack solutions for

customer rooms of all sizes to knürr,MESA® and

Netspan™、Matrix™ enclosures and shelters for

wireline and wireless applications.

RACKS & INTEGRATED CABINETS .Yet another

way Emerson Network power enables Business-

Critical Continuity™.

RACKS & INTEGRATED CABINETS

EMERSON NETWORK POWER.

THE GLOBAL LEADER IN ENABLING

BUSINESS-CRITICAL CONTINUITY.™

AC POWER

CONNECTIVITY

DC POWER

EMBEDDED COMPUTING

EMBEDDED POWER

MONITORING

OUTSIDE PLANT

POWER SWITCHING

& CONTROLS

PRECISION COOLING

RACKS & INTEGRATED

CABINETS

SERVICES

SURGE PROTECTION

41

Page 46: Power System, Rectifier

Server Enclosure Systems Rack system and IT total solution

Emerson Network Power Co.,Ltd. Launched the high reliability and high availability rack system and IT room total solution that suit the features of blade server based on its deep understanding in the user’s requirements for IT application and the existing issues.

ApplicationsNetwork access rooms

Computer rooms

Data center

Features and BenefitsWorld-leading heat dissipation design: The 83% perforating rate that is the highest in the world

meets the heat dissipation requirement of high thermal-density of blade server

Special modular structure: Modular structure and modular installation: Convenient storage and

transportation, fast and convenient disassembly and assembly

Reliable and stable power supply and distribution design: double conversion online UPS, the total

power distribution solution meets the different customer requirements

Convenient cable management: Comprehensive cable management accessories meet the

different cable management requirements

Advanced rack monitoring and safety system: Remote monitoring to the rack environment,

including temperature, humidity, door alarm and smoke, etc

Miracel Series:Product Type Capacity Width(mm) Distance(mm) High(mm)

NR-M060820 42U 600 800 2000

SR-M061020 42U 600 1000 2000

SR-M061220 42U 600 1200 2000

SR-M081020 42U 800 1000 2000

SR-M081220 42U 800 1200 2000

Accessories Fan, plinth, cable management unit, power distribution unit, etc.

42

Racks & Integrated Cabinets

Page 47: Power System, Rectifier

Maintaining precise temperature for reliable equipment

performance. We deliver “chip-to-room cooling”-the

most comprehensive range of liebert® precision-cooling

solutions,which protect mission-critical applications

from even the slightest increase in temperature.

PRECISION COOLING. Yet another way Emerson

Network power enables Business-Critical Continuity™.

PRECISION COOLING

EMERSON NETWORK POWER.

THE GLOBAL LEADER IN ENABLING

BUSINESS-CRITICAL CONTINUITY.™

AC POWER

CONNECTIVITY

DC POWER

EMBEDDED COMPUTING

EMBEDDED POWER

MONITORING

OUTSIDE PLANT

POWER SWITCHING

& CONTROLS

PRECISION COOLING

RACKS & INTEGRATED

CABINETS

SERVICES

SURGE PROTECTION

43

Page 48: Power System, Rectifier

Liebert DataMate3000(S) Precision cooling for Small Equipment Rooms

DataMate3000 series air conditioning is developed by Emerson Network Power

Co., Ltd. for small equipment rooms. The system provides 5.5kW , 7.5kW and

12.5kW cooling capacities and many confi guration options.

Dimensions And Weightmodel W×D×H, mm Weight (kg) Capacity

DataMate3000(s)

Indoor model

DME05W 510×386×1740 80 5.5 kW

DME07W 510×386×1740 85 7.5 kW

DME07M 500×550×1900 150 7.5 kW

DME12M 500×550×1900 160 12.5 kW

Outdoor modelDMC07W 702×408×626 34 7.5kW

DMC12W 702×408×1238 58 12.5 kW

Features and BenefitsHigh sensible cooling capacity and energy efficient. Saves 20-30% energy as compared to

"comfort" air conditioner

Provides constant temperature and humidity, high air fl ow rate and low energy consumption to

meet specifi c reqirements of computer rooms

Copeland scroll compressor provides high reliability, effi ciency and maximum life

Large LCD display, password protection and self diagnosis

Wide input voltage range, allowing voltage fl uctuation 20%

Phase loss protection ,phase order detection, automatic regulation to phase disorder

Automatic startup when utility is recovered

Front access ,easy for maintenance and fl exible installation

Standard port for monitoring equipment

Flexible and automatic switchover and alternative operation between master and slave

ApplicationsMobile base stations and control centers

Communications base stations

Outdoor equipment rooms

Microwave/Satellite earth stations

Medium ,Small computer rooms

44

Precision Air Conditioning

Page 49: Power System, Rectifier

Liebert PEX Precision cooling for medium/large equipment room

The Liebert PEX is the next generation precision air conditioning system from

Emerson Network Power. The PEX is the latest in a long line of advanced

products from the Liebert family designed to support business-critical

applications.

Features and BenefitsFront access for convenient maintenance. There is no need to keep back or sides clear

The Liebert iCOM™ control system offers the highest capabilities of unit control, communication

and monitoring

ICOM network provides a choice of Teamwork, Lead/Lag and Cascade functions

A-Frame Evaporator Coils has larger surface to provide even air flow distribution. Its heat exchange

is highly efficient

Unique fan driving system ensures stable system operation and more efficient airflow

Infrared Humidifier, Full capacity achieved in 5-6 seconds using almost any water quality;

Approved for direct connection to potable water supplies; Autoflush™ cycle helps remove mineral

deposits

All compressorised models are designed to operate on either HCFC R22 or HFC R407C refrigerants

High kW to footprint ratio

ApplicationsData Centres

Telecom/CATV

Computer Rooms

Labs and Test Rooms

Network Centres

Production Facilities

Hospitals and medical diagnostic rooms

45

Business-Critical Continuity™

Page 50: Power System, Rectifier

Dimensions And Weight

modelTotal Capacity(kW)

(24℃/50%RH)Weight (kg) L×W×H, mm

P1020 20.0 365

853×874×1970P1025 23.1 375

P1030 30.1 385

P1035 33.1 388

P2045 45.0 530

1704×874×1970

P2055 53.2 570

P2040 41.0 622

P2050 46.4 661

P2060 60.6 680

P2070 66.9 687

P3080 81.4 825

2553×874×1970P3090 89.3 825

P3100 100.0 835

46

Precision Air Conditioning

Page 51: Power System, Rectifier

Liebert XDFlexible, Energy-Saving Cooling Solutions For High Heat Density Applications

ApplicationsIDC

Blade servers

High density servers and communications switches

Rooms existing high heat density

Dimensions And Weight

modelTotal Capacity(kW)

(24℃/50%RH)Weight (kg) W×D×H, mm

Main UnitXDP160 140 372 965×864×1981

XDC160 130 817 1879×879×1981

Cooling Module

XDO20 17.7 68 1829×610×572

XDV10 8.3 35 597×(749-1003)×355

XDH20 19 112 300×1066×1982

XDH32 27 112 300×1066×1982

Features and BenefitsCan cool more than 30 kW per rack

Floor-mount, rack-mount and ceiling-mount modules, plus a choice of cooling capacities, cover

any application requirements

Pumped refrigerant solutions are ideal for use around electronic equipment. No water into the

room

Scalable – add or move fan coils as your needs

Energy effi cient. Total energy savings potential of up to 40% can be achieved with the Liebert XD

solution

Minimal fl oor space requirements allow more room for IT equipment

47

Business-Critical Continuity™

Page 52: Power System, Rectifier

Managing critical equipment activity at multiple

sites and site monitoring around the clock. We

make it easy in today’s ROL-driven business

environment,with 24/7 remote and self-

monitoring systems and services that provide

continuous oversight of data centers,computer

rooms and network closets,as well as wireless,

wireline and enterprise telecom applications.

MONITORING. Yet another way Emerson Network

power enables Business-Critical Continuity™.

MONITORING

EMERSON NETWORK POWER.

THE GLOBAL LEADER IN ENABLING

BUSINESS-CRITICAL CONTINUITY.™

AC POWER

CONNECTIVITY

DC POWER

EMBEDDED COMPUTING

EMBEDDED POWER

MONITORING

OUTSIDE PLANT

POWER SWITCHING

& CONTROLS

PRECISION COOLING

RACKS & INTEGRATED

CABINETS

SERVICES

SURGE PROTECTION

48

Page 53: Power System, Rectifier

Emerson Power Equipment And

Environment Monitoring System

Emerson Power Equipment and Environment Monitoring System is applicable to monitoring in real time and managing in unity power supply equipment (power system, battery, UPS, generator and low-voltage distributor), airconditioning equipment and environment(door alarm, temperature, humidity, smoke detection, water immersion, infrared and scene)in telecom exchanges and base stations

After11-year development and optimization, Emerson monitoring system has become a total solution including hardware, software and transmission products. The monitoring solution can be customized to adapt to different regions, different maintenance management mechanisms, different exchanges and different transmission resources. The solution can meet the demands of monitoring the whole power equipment, environment of both fixed and mobile telecom networks

SeriesEmerson power equipment and environment monitoring system

Single version system

ApplicationsPower equipment and environment monitoring systemApplicable to monitoring power equipment, environment in switch site, base stations,transmission

relay stations

Features Of Monitoring Centersupervision center SC consists of database server, console, printer and auxiliary equipmentThe server collects, saves, analyzes and manages all monitoring data from monitoring end office

SU. It gives various alarms (sound & light alarm, email, message, etc.) in case of monitored object's

failure

Fexible Transmission NetworkingMonitoring center SC, monitoring station SS and monitoring end office SU can form a wide area

network through IP, 2M, DDN, ISDN, PSTN and WAN

BenefitsReal time alarmsIn case of monitored object's failure,

the monitoring system can give alarm

within 30 seconds

Multiple alarm reportsThere are sound & light alarm, printed

alarm, paging alarm,mobile short

message alarm, E-mail alarm and voice

alarm

Flexible networkingFlexible single or mixed networks can

be set up through CE1, DDN/LL, ISDN,

PSTN and WAN

Supports maintenance managementP r o v i d e s m a i n t e n a n c e a n l y s i s

data,improves maintenance efficiency

and cuts maintenance cost

Real time data collectionThe system operates around the clock

and reports in real time the monitored

e q u i p m e n t a n d e n v i r o n m e n t ' s

conditions. The system provides first-

hand data to evaluate equipment

conditions.

Wide-range monitored objectsThe monitored objects include HV

a n d L V d i s t r i b u t i o n e q u i p m e n t ,

power system, air conditioning,diesel

generator, battery and UPS; and also

include environment data in relation

to temperature, humidity, water

immersion, smoke and door

49

Business-Critical Continuity™

Page 54: Power System, Rectifier

Communication Solution of

Monitoring System

IP Networking

Features:Using the available

TCP/IP network in site

Supportive of HTTP, TELNET, FTP

Remote debugging and upgrade

Applicable to:IDC room, MSC room, 3G base station, GPRS and CDMA site

Server

LAN

IDU IDU

IDU

IDUIDU

IDU

E1 E1

BRG-POOL

LAN

IDUIDU IDUIDU IDU IDU

Console

Host

IP network

Server Console

Host

Emerson Power Equipment And Environment

Monitoring Software V4.39

Emerson IP Video Monitoring Software

50

Monitoring

Page 55: Power System, Rectifier

Solution of large siteThe SU has IDU and sensors

Applicable to: exchange station, switch centers ( MSC)

Monitored equipment: HV and LV, generator diesel, AC distribution, rectifier, DC distribution,

battery strings,DC converter, inverters and air-conditioner, it can also be applied to acquire

theenvironment data, such as smoke detector, temperature and humidity sensor, access control

andwater detector

solution of small siteThe SU has IDU and sensors

Applicable to: base station (BTS)

Monitored equipment: Low Voltage, DC power, air-conditioner, temperature and humidity sensor,

diesel level, smoke detector, door accessl and water detector

Low Voltage Distribution

DC Power

Air Condition

Battery

Generator

IDU-HOST

Transmission

DC PowerDC Power

Monitoring Center

Intrusion detector For Door

Smoke Detector

Water Leakage

Temperature And Humidity

diesel level

Communication linePower line

Transmission

IDU-HOSTdiesel leveldiesel level

Intrusion detector

Smoke Detector

Water Leakage

Temperature And Humidity

A i r Condition

DC Power

Power meter

51

Business-Critical Continuity™

Page 56: Power System, Rectifier

IDU series product specificationsmodel BOM Description Functions

IDU-HOST 02311425 IDU host

10 AI inputs (compatible with digital signals), 4 DI inputs, 1 THS

temperature/humidity input channel, 4 relay outputs, with 4 serial

ports, 2 battery group voltage channels, 1 Ethernet port, 1 USB port and

2 expansion slots

IDU-BAT1 02311434Battery board 1

(1 battery group)

Capable of monitoring 24 battery cells, 1 charge/discharge current,

auto-switchover among measurement ranges of 2V, 6V and 12V

IDU-BAT2 02311427Battery board 2

(2 battery groups)

capable of monitoring 48 battery cells, 2 charge/discharge currents,

auto-switchover among measurement ranges of 2V, 6V and 12V

IDU-BRG1 02311438E1-IP network bridge

communication board

2 Ethernet ports (LAN), 1 E1 port (point-to-point, cannot be upgraded

to double loop

IDU-BRG2 02311429Double E1-IP network bridge

communication board2 Ethernet ports (LAN), 2 E1 ports (supportive of double loop)

IDU-THS 33030018External THS temperature/

humidity sensor

Temperature measurement range: -10℃~50℃. Precision: +/-2℃Humidity measurement range: 5~95%RH. Precision: +/-5% (20~

80%RH, 25℃)

IDU series product mechanical specificationsName Sizes Weight

IDU-HOST 440 ± 1mm × 295 ± 1mm × 44 ± 1mm ≤5kg

IDU-BAT1 122 ± 1mm × 185 ± 1mm × 1.6mm ≤0.5kg

IDU-BAT2 122 ± 1mm × 185 ± 1mm × 1.6mm ≤0.5kg

IDU-BRG2 122 ± 1mm × 185 ± 1mm × 1.6mm ≤0.5kg

BRG-POOL 440 ± 1mm × 295 ± 1mm × 44 ± 1mm ≤5kg

The features of IDU includeIP-network based, supportive of TCP/IP and network protocols such as HTTP, TELNET, FTP, TFTP

and DHCP

TELNET remote debugging

Highly integrated, with superb processing and storing ability of bottom data

Integrated connection with multiple intelligent devices

Low cost image monitoring solution (USB image and anti-burglary)

High standard lightning protection for all ports. Built-in SPDs are used for all ports, with lightning

protection ability 2-times higher than the international standard

Hardware self-diagnostic ability, including detection of E1 cable status, detection of board

insertion fault, and measurement of CPU usage

Network management function: IP flux statistics, IP contradiction auto-detection, and network

topology structure

Remote on-line upgrading of software

IP networking mode, supportive of transmission modes of double loop, ADSL and E1

Supportive of ADSL static IP address

52

Monitoring

Page 57: Power System, Rectifier

BRG-POOLBRG-POOL bridge pool ( BRG-POOL) is conversion device for E1-IP transfer function. It provides

eight independent E1-IP transfer channels and can be flexibly configured through CONSOLE

portaccording to the actual application conditions and meet the requirements of different

networkingmodes

BRG-POOL specificationsmodel Voltage input range Power

BRG-POOL -38V ~ -60Vdc <20W

model Dimensions Weight

BRG-POOL 440mm × 295mm × 44mm < 5kg

parameters Transmission distance

10/100M, half/full-duplex self-adaptable, RJ45 port,

Ethernet cable intercross function100m max.

53

Business-Critical Continuity™

Page 58: Power System, Rectifier

Making power conversion easy for IT and

communications equipment. We deliver a broad

offering of Astec® and Artesyn® solutions,

including AC/DC and DC/DC power supplies,

adapters,chargers and power accessories.

EMBEDDED POWER.Yet another way Emerson

Network power enables Business-Critical

Continuity™.

EMBEDDED POWER

EMERSON NETWORK POWER.

THE GLOBAL LEADER IN ENABLING

BUSINESS-CRITICAL CONTINUITY.™

AC POWER

CONNECTIVITY

DC POWER

EMBEDDED COMPUTING

EMBEDDED POWER

MONITORING

OUTSIDE PLANT

POWER SWITCHING

& CONTROLS

PRECISION COOLING

RACKS & INTEGRATED

CABINETS

SERVICES

SURGE PROTECTION

54

Page 59: Power System, Rectifier

GIE4805/2A/500-2Mini Power System

Key Features1 U Height and designed for 19” racks

Integrated Battery Low Voltage Disconnection function

GIE4805/2A/500-2Nominal system voltage: -48 V

System rated output power @ - 54 V: 540 W

Rectifier rated output power @ - 54 V: 270 W

DC distribution branchBranch 1 10A(FUSE)

Branch 2 10A(FUSE)

Battery 10A(FUSE)

AC input range: 90-264 V AC

Safety EN 60950

Sub rack dimensions (H x W x D): 43 x 482 x240mm

Key BenefitsSpace efficient solution with all functions integrated

55

Business-Critical Continuity™

Page 60: Power System, Rectifier

GEPS4820F/01-10/22-EN Mini Power System

Key Features1 U Height and designed for 19”racks

Integrated LVD and priority load

GEPS4820F/01-10/22-ENNominal system voltage: - 48 V

System rated output power @ - 54 V: 1600 W

Rectifi er rated output power @ - 54 V: 800 W

DC distribution branchBranch 1 10A(FUSE)

Branch 2 20A(FUSE)

Battery 20A(FUSE)

AC input range: 90-290 V AC

Safety EN 60950, UL 60950

Sub rack dimensions (H x W x D): 45.6 x 482.6 x 325mm

Key BenefitsSpace effi cient solution with all functions integrated

56

Embedded Power

Page 61: Power System, Rectifier

GIE4815/2A/1.7KWMini Power System

Key Features2 U Height and designed for 19”racks

Integrated AC distribution, LVD and priority load

Remote monitoring and dry contacts

GIE4815/2A/1.7KWNominal system voltage: - 48 V

System rated output power @ - 54 V: 1700 W

Rectifier rated output power @ - 54 V: 850 W

DC distribution branchBranch 1,2 5A(FUSE)

Branch 3 10A(FUSE)

Branch 4,5 20A(FUSE)

Battery 50A(MCB)

AC input range: 90-290 V AC

Safety EN 60950, UL 60950

Sub rack dimensions (H x W x D): 88 x 483 x 350mm

Key BenefitsSpace efficient solution with all functions integrated

57

Business-Critical Continuity™

Page 62: Power System, Rectifier

GIE4815/3A/2.55KW Mini Power System

Key Features3 U Height and designed for 19”racks

Remote monitoring and dry contacts

Integrated AC distribution, surge protection, LVD and priority load

GIE4815/3A/2.55KWNominal system voltage: - 48 V

System rated output power @ - 54 V: 2550 W

Rectifi er rated output power @ - 54 V: 850 W

DC distribution branchBranch 1, 10A(MCB)

Branch 2,3 20A(MCB)

Branch 4, 50A(MCB)

Battery 63A(MCB)

AC input range: 90-290 V AC

Safety EN 60950, UL 60950

Sub rack dimensions (H x W x D): 133 x 465 x 360mm

Key BenefitsSpace effi cient solution with all functions integrated on one shelf

Robust and well proven design for tropical climates

Provides reliable DC supply

58

Embedded Power

Page 63: Power System, Rectifier

GIE4820/3A/3.45KWMini Power System

Key Features3 U Height and designed for 19”racks

Remote monitoring and dry contacts

Integrated AC distribution, surge protection, LVD and priority load

GIE4820/3A/3.45KWNominal system voltage: - 48 V

System rated output power @ - 54 V: 3450 W

Rectifier rated output power @ - 54 V:1150 W

DC distribution branchBranch 1, 10A(MCB)

Branch 2,3 20A(MCB)

Branch 4, 50A(MCB)

Battery 63A(MCB)

AC input range: 90-290 V AC

Safety EN 60950, UL 609 50

Sub rack dimensions (H x W x D): 133 x 465 x 360mm

Key BenefitsSpace efficient solution with all functions integrated on one shelf

Robust and well proven design for tropical climates

Provides reliable DC supply

59

Business-Critical Continuity™

Page 64: Power System, Rectifier

Emerson Network Power Co., Ltd.No. 1 Kefa Rd., Science & Industry ParkNanshan District 518057, Shenzhen, ChinaPhone: +86-755-8601-0808

Emerson Network Power. The global leader in enabling Business-Critical Continuity™. www.emersonnetwork.com.cn

Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.

E-X6210486-0708

AC Power Systems Embedded Power Outside Plant

Connectivity Inbound Power Precision Cooling

DC Power Systems Integrated Cabinet Solutions Site Monitoring and Services