power supplies qom-dc+cap -...

1
MULTI-VOLT & TAPS • Primary Taps: 12VDC : 11, 12, 13, 14, 15v 24VDC : 22, 24, 26, 28, 30v ( See Q-TRAN Voltage drop Calculator ) • Secondary Circuit Protection: 1-2 magnetic circuit breakers. • The advantage is that loads at varying distances from the PSC can be tapped on different taps to recover voltage drop, allowing you to get the correct voltage at your load and produce between 85%-100% light output. • Loads may be connected to one (1) of the primary taps up to the • No De-Rating required. full watt rating of the PSC. * Call for custom voltages PROJECT NAME DATE TYPE NOTE COMPANY © 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460.All rights reserved -P: 203-367-8777-F: 203-367-8771- E: [email protected] - www.q-tran.com QOM-DC+CAP POWER SUPPLIES LOW VOLTAGE LIGHTING POWER SUPPLY SURFACE MOUNTANY POSITION LISTED TO SAME STANDARD AS UL 1838 WALL MOUNT/ROD SUSPENSION FOR SUPPLY CONNECTIONS USE WIRE RATED FOR AT LEAST 75°C SUITABLE FOR DAMP AND WET LOCATIONS USE DIMMERS RATED FOR MAGNETIC LOW VOLTAGE LOAD WITH NEUTRAL WIRE ISOLATION TOROIDALTRANSFORMER 50/60 CyCLE MADE INTHE U.S.A. 239924 * For information on this Power Supply please consult the Q-Tran Indoor catalog or visit the Q-Tran website. 4.875” 4.250” 8.0” 14.5” 368.3mm Q-Tran’s QOM-DC+CAP is a surface mount, exterior rated, rectified DC power supply with a built in capacitor. It is CSA listed for us with exterior and submersible luminaries and LED luminaries, as well as submersible pumps. It is ideal for applications that require perfect dimming, the DC+CAP will dim down to off without any flicker. When dimming use a forward phase dimmer with a neutral wire. TOROIDAL CHOKE Q-Tran’s Standard Choke, or “Debuzzing Coil” reduces noise when dimming and helps negate in-rush current that is prevalent with LED loads. It allows for quiet operation and eliminates nuisance tripping. QOM-60DC+CAP - 120/12 - 1x5 + CK - S QOM-DC+CAP CAP 1 to 2 1 Size Max Lamp Load (Watts) Max Prim. Amps @ 120V Max Prim. Amps @ 277V 2 Primary Voltage 120 (60Hz) 230 (50/60Hz) 230 (50/60Hz) 240 (50/60H CK-S 60W-200W Standard z) 277 (60Hz) 3 Transformer Secondary Voltage 4 Number of Breakers 6 Number of Breakers Ordering Example Fixtrure Volts(58VDC) 2.5 30W 4 48W 5 60W 5 Secondary Breaker Amperage AMPS Max 12V Load Max 24V Load 6 & 7 Options BK Black Powder Coat SS* 316L Satin Stainless Housing and Door Finish * Not Standard, Call Factory For options 60DC+CAP 60W 12V DC 0.9 A 0.4 A 120DC+CAP 120W 12V DC 1.4 A 0.6 A 60DC+CAP 60W 24V DC 0.9 A 0.4 A 100DC+CAP 100W 24V DC 1.3 A 0.5 A 200DC+CAP 200W 24V DC 2.4 A 1.0 A 12VDC 24VDC 60W 96W 120W CP* Cord & Plug 1.36" 1.07" 4 Knockouts of 1.36" Hole for 1" fitting 5 Knockouts of 1.07" Hole for 3/4" fitting

Upload: others

Post on 14-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: POWER SUPPLIES QOM-DC+CAP - Q-Tranlegacy.q-tran.com/sites/default/files/QOM-DC+CAP-cutsheet-2016.pdf · Q-Tran’s QOM-DC+CAP is a surface mount, exterior rated, rectified DC power

MULTI-VOLT & TAPS

• Primary Taps:12VDC : 11, 12, 13, 14, 15v24VDC : 22, 24, 26, 28, 30v

( See Q-TRAN Voltage drop Calculator )

• Secondary Circuit Protection: 1-2 magnetic circuit breakers.

• The advantage is that loads at varying distances from the PSC can be tapped on different taps to recover voltage drop, allowing you to get the correct voltage at your load and produce between 85%-100% light output.

• Loads may be connected to one (1) of the primary taps up to the

• No De-Rating required. full watt rating of the PSC.

* Call for custom voltages

PROJECT NAME DATE TYPE NOTECOMPANY

© 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460.All rights reserved - P: 203-367-8777- F: 203-367-8771 - E: [email protected] - www.q-tran.com

QOM-DC+CAP

POWER SUPPLIES

LOW VOLTAGE LIGHTING POWER SUPPLY• SURFACE MOUNTANY POSITION• LISTED TO SAME STANDARD AS UL 1838 • WALL MOUNT/ROD SUSPENSION• FOR SUPPLY CONNECTIONS USE WIRE RATED FOR AT LEAST 75°C• SUITABLE FOR DAMP AND WET LOCATIONS• USE DIMMERS RATED FOR MAGNETIC LOW VOLTAGE LOAD WITH NEUTRAL WIRE• ISOLATION TOROIDALTRANSFORMER• 50/60 CyCLE• MADE INTHE U.S.A.

239924

* For information on this Power Supply please consult the Q-Tran Indoor catalog or visit the Q-Tran website.

4.87

5”

4.25

0”

8.0”

14.5

”36

8.3m

m

Q-Tran’s QOM-DC+CAP is a surface mount, exterior rated, rectified DC power supply with a built in capacitor. It is CSA listed for us with exterior and submersible luminaries and LED luminaries, as well as submersible pumps. It is ideal for applications that require perfect dimming, the DC+CAP will dim down to off without any flicker. When dimming use a forward phase dimmer with a neutral wire.

TOROIDAL CHOKE

Q-Tran’s Standard Choke, or “Debuzzing Coil” reduces noise when dimmingand helps negate in-rush current that is prevalent with LED loads. It allows for quiet operation and eliminates nuisance tripping.

Max Prim. @ 277V

QOM-60DC+CAP - 120/12 - 1x5 + CK - S

QOM-DC+CAP CAP

1 to 2

1 Size Max Lamp Load (Watts)

Max Prim. Amps @ 120V

Max Prim. Amps @ 277V

2 Primary Voltage

120 (60Hz) 230 (50/60Hz) 230 (50/60Hz) 240 (50/60H

CK-S 60W-200W Standard

z) 277 (60Hz)

3 Transformer Secondary Voltage

4 Number of Breakers

6 Number of Breakers

Ordering Example

Fixtrure Volts(58VDC)

2.5 30W4 48W5 60W

5 Secondary Breaker AmperageAMPS Max 12V Load Max 24V Load 6 & 7 Options

BK Black Powder Coat

SS* 316L Satin StainlessHousing and Door

Finish

* Not Standard, Call Factory For options

60DC+CAP 60W 12V DC 0.9 A 0.4 A120DC+CAP 120W 12V DC 1.4 A 0.6 A

60DC+CAP 60W 24V DC 0.9 A 0.4 A100DC+CAP 100W 24V DC 1.3 A 0.5 A200DC+CAP 200W 24V DC 2.4 A 1.0 A

12VDC 24VDC

60W96W120W

CP* Cord & Plug

1.36"

1.07"

4 Knockouts of 1.36" Holefor 1" fitting