SAFRAN ELECTRICAL & POWER 2120 LABINAL POWER SYSTEMS TF300-9E
POWER RELAYS — GASKET SEALED - 100 AMPS TO 1,000 AMPS
Typical Characteristics
Specifications• Design to meet the general
requirements of MIL-R-6106Type II continuous DutyUnsealed
• Contacts are covered & gasketed• Double break contacts• All units are thermal breaker
compatible at rated relayresistive load
• Some models available withauxiliary circuits
• Gold-plated auxiliary contactsfor low-level applicationsavailable
• Auxiliary contacts ratings:28 Vdc: 5 amps resistive
3 amps inductive2.5 amps lamp
Ratings Per MIL-R-6106:• Salt spray, humidity,
accelera tion, sand & dust,intermediate current
• Vibration:5 to 10 Hz -.08 DA10 to 55 Hz -.05 DA55 to 500 Hz -2.0 g's
• Shock: 25 g's (6-9 MS ½ sinewave)
• Life: (-55 to 71°C)50,000 cycles electrical atfull rated load100,000 cycles mechanical tested at 25% rated load
• Altitude: 50,000 feet
Typical Characteristics (Figures 1 through 8)(For additional details, con-tact your local Safran Electrical & Power Technical Sales Representative)
• Power Contact Voltage Drop:Initial 0.15 V After Life Test: 0.175 V
• Insulation Resistance: Initial200 Meg ohm.
• After Life Test: 100 Meg ohm
Dielectric Withstanding Voltage:
2.5 Seconds Sea LevelInitial: 1250 VAfter Life Test: 1000 VPower Contacts: 650 V
50,000 Feet 60 SecondsInitial & After Life Test: 500 V
Circuit Diagrams
A1 A2
#1
X1
X2
#2
X1
X2
A1
13
12
11
A2
23
22
21
A2
#3
X1
X2
B1
A1
12
11
11
A2
23
22
21
A1 A2
#1
X1
X2
#2
X1
X2
A1
13
12
11
A2
23
22
21
A2
#3
X1
X2
B1
A1
12
11
11
A2
23
22
21
A1 A2
#1
X1
X2
#2
X1
X2
A1
13
12
11
A2
23
22
21
A2
#3
X1
X2
B1
A1
12
11
11
A2
23
22
21
#1#2 #3
Part Number Rated Contact Load Rupture Current
Contact Rating
28 Vdc Intermittent Power
28 Vdc
Res. Ind. Motor Intermediate 15Minute
5Minute
1Minute
Max.o
Inrush
SM100D2SM100D3SM150D1SM150D2SM150D3SM150D4SM150D5l
SM200D1SM200D2SM200D3SM400D1SM400D2SM400D3SM1000D11r
100100
150n
150n
150n
150n
1502002002004004004001000
80805050505050100100100100100100—
100100
150150150150150200200200400400400—
44151515151520202040404050
10001000120012001200120012002000200020004000400040006000
1301301951951951951952602602605205205201200
1501502252252252252253003003006006006001500
200200300300300300300400400400800800800
2000
600600900900900900900120012001200240024002400
2500s
600 Amp make, 200 Amp breakkDuty cycle: 1 minute on, 1 minute off; 1 minute on, 20 minutes offlMaximum vibration 2000 Hz 2 g’smDuty cycle: 1.5 minutes on, 3 minutes offnWill carry 200 Amps at 20% on duty cycle per minuteoMaximum inrush provided coil voltage as noted is maintainedpOperate time at 28 Vdc & 25 deg. C.qContact bounce is average of 5 conse cutive ratings.rAvailable in normal closed circuit.s 1 sec. on, 60 sec. off
“Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited.”
-
LABINAL POWER SYSTEMS TF300-9E 2322 SAFRAN ELECTRICAL & POWER
POWER RELAYS — GASKET SEALED - 100 AMPS TO 1,000 AMPS
Insulation Resistance:Initial: 100 Meg ohmsAfter Life Test: 50 Meg ohms
Dielectric Withstanding Voltage:(2.5 Seconds Sea Level)Initial: 1250 VAfter Life Test: 1000 V
Dimensions (See next page for other dimension figures)
Figure 9
Life at 1000 Amps limited to 10,000 cycles. Life at 50 Amps is 50,000 cycles minimum. Rupture life is 20 cycles at 6000 Amps. This unit is available with inverted termi-nals, bottom mounting, available with normally closed power contacts, and DPDT auxiliary circuits.
Unit Shown Without Auxiliary Contacts
Contact TransferMilliseconds, Max.
Coil Data
Op.o
TimeRel.
TimeContact
BounceqPoles
& ThrowWeightLbs./gm
CircuitDia.
DimensionFig.
Res.(OHMS)
Max.VoltsPick Up
MaxVolts-Drop Out
DutyCycle
Mounting AuxiliaryTermination
PartNumber
3535404015154025252540402060
1515151512121510101815151530
6655555
2.52.551010103
SPST/NOSPST/NOSPST/NOSPST/NO
SPDTSPDTSPDT
SPST/NOSPST/NOSPST/NOSPST/NOSPST/NOSPST/NOSPST/NO
0.6/2720.6/2720.95/4300.95/4301.25/5671.25/5671.25/5671.3/5881.3/5881.3/5882.6/11772.6/11772.6/11774/1810
11223332222221
12334445667889
94.294.282.782.76.66.66066661060601038
1818
16.516.56.56.51818187.518187.018
7 to 1.57 to 1.51 to 71 to 7
0.2 to 30.2 to 3
0.6 to 8.51.5 to 71.5 to 70.5 to 31.5 to 71.5 to 70.5 to 31 to 7
ContContContCont
InterkInterkContContCont
IntermContCont
IntermCont
SideTopBBBBB
SideBB
SideBB
Side
——
ScrewIWTSScrewIWTSScrew
LugLugLugLugLugLug—
SM100D2SM100D3SM150D1SM150D2SM150D3SM150D4SM150D5SM200D1SM200D2SM200D3SM400D1SM400D2SM400D3
SM1000D11
600 Amp make, 200 Amp break
kDuty cycle: 1 minute on, 1 minute off; 1 minute on, 20 minutes off
lMaximum vibration 2000 Hz 2 g’s
mDuty cycle: 1.5 minutes on, 3 minutes off
nWill carry 200 Amps at 20% on duty cycle per minute
oMaximum inrush provided coil voltage as noted is maintained
pOperate time at 28 Vdc & 25 deg. C.
qContact bounce is average of 5 consecutive ratings.
rAvailable in normal closed circuit.
“Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited.”
-
SAFRAN ELECTRICAL & POWER 2322 LABINAL POWER SYSTEMS TF300-9E
POWER RELAYS — GASKET SEALED - 100 AMPS TO 1,000 AMPS
Dimension Figures
Figure 1 Figure 2
Figure 3 Figure 4
X1 X2
1.875(47.62)
2.385(60.55)
.937 (23.8)
.219 (5.56) DIA.(2) MOUNTING
HOLES
.422 (10,7)
2.68(68.0)
#6-32 UNC-2A2 COIL TERM
1.72
(43.
69).
986
(25.
0)
.625(15.87)
2.22(56.38)
2.75
(69.
85)
.250(6.35)-28 UNF-3A2 Power Term
SM100D2 SM100D3
SM150D4
Unit Shown Without Auxiliary Contacts
2.64(67)
.219(5.56) DIA. MOUNTING HOLES
1.312(33.3)
2.68
(68)
2.22(56.3)
2.188(55.5)
.250 (6.35)-28 UNF-3A2 POWER TERM
.625(15.8)
2.68(68)
1.72
(43.
6)
X2 X1
SM150D1
SM150D2
SM150D3SM150D5
SM150D4
SM150D2
Unit Shown Without Auxiliary Contacts
X2X1
A2
A1
WILL ACCEPT TERMINAL-PINCONNECTION (DEUTSCH PARTNO. 1841-1-5620)
.203 (5.15) ± .005 DIA.4 MOUNTING HOLES
2.75
(69.
8)
187
MTG
(47.
5)
2.19
(55.
6)
1.87 MTG
(47.5)
4.50
(114
.3)
2.25
(57.1)
2.25
(57.1)
#6-32 UNC-2A6 AUX. TERMINALS
#6-32 UNC-2A2 COIL TERMINALS
.75
(19)
.250 (6.35)-28 UNF-2A2 POWER TERMINALS
X2X1
B2
B3
A2
A1
.250 (6.35)-28 UNF-2A4 POWER TERMINALS
WILL EXCEPT TERMINAL-PINCONNECTION (DEUTSCH PARTNO 1841-1-5620)
.203 (5.15) ± .005 DIA.4 MOUNTING HOLES
2.75
(69.
8)
187
MTG
(47.
5)
2.19
(55.
6)
1.87 MTG(47.5)
4.50
(114
.3)
2.25(57.1)
2.25(57.1)
#6-32 UNC-2A6 AUX. TERMINALS
#6-32 UNC-2A2 COIL TERMINALS
.75(19)
.75(19)
“Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited.”
-
LABINAL POWER SYSTEMS TF300-9E 2524 SAFRAN ELECTRICAL & POWER
POWER RELAYS — GASKET SEALED - 100 AMPS TO 1,000 AMPS
Dimension Figures
Figure 5 Figure 6
Figure 7 Figure 8
SM200D1
SM400D1
SM200D2SM200D3
SM400D2SM400D3
2.00(50.8)
.916(23)
.984
(25)
3.85
(97.
8)
.266 2 MTG. HOLES(6.75)
.781
(1
9.8)
X2X1
A2A1
4.00(101.6)
2.395(60.8)
3.5(68.9) 4.500
(76)
.375 (9.5)- UNF-2A
#6-32 UNC-2ACOIL TERMINALS
.058 (1.47) DIA. TERMINALSTO FIT "AMP" LUG PT.NO. 61276-2
.058 (1.47) DIA. TERMINALS TO FIT"AMP" LUG PT 61276-2
4.38 MAX(61.93)
4.31(109.47)
1.05(26.67)
TYP.
5.50(139.70)
1.06
(26.
9)3.
92(9
9.57
)
1.28
(32)
MA
X
.81
(20.
57)
2.406(61.11)
.500 (12.7)-20 UNF-2APOWER TERMINAL
#6-32 UNC-2ACOIL TERMINAL
.266 (6.76) DIA.2 HOLES FOR MTG
MAX.
A2A1
X1 X2
.058 DIA. TERMINALS TO FIT "AMP" LUG
PT 61276-2
1.219 MAX.
.266(6.76)
2 HOLES FOR MOUNTING
3.25
(82.
55)
3.000(76.20) 3.53
(89.66)MAX.
1.89(48.01)
1.00
0±.
125
.475
.500MIN.
5.500(139.70)
MAX.
.062(1.575)
4.45
(113
.03)
MA
X.
2.438 MAX.
4.312(109.47)
2.25
(57.
15)
A2
X2 X1
A1
2 X STUD, THD .138-32 UNC-2A2 X STUD, THD .500-20 UNF-2APOWER TERMINAL
.058 DIA. TERMINALSTO FIT “AMP” LUGPT 61276-2 1.219 MAX.
.266(6.76)
2 HOLES FOR MOUNTING
3.25
(82.
55)
3.000(76.20) 3.65
(92.7)MAX.
1.89(48.01)
±.12
5(1
.13)
.475
.500 MIN.
5.500(139.70)
MAX.
.062(1.575)
4.45
(113
.03)
MA
X.
2.438 MAX.
4.312(109.47)
2.25
(57.
15)
A2
X2 X1
A1
2 X STUD, THD .138-32 UNC-2A
2 X STUD, THD .500-20 UNF-2APOWER TERMINAL
“Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited.”