power quality analizer (ca_8332)
TRANSCRIPT
-
8/12/2019 Power Quality Analizer (Ca_8332)
1/6
y(
)
Displa y your ne tw o rk
a na lysis a ll in pictu re fo rma t!
Ready-to-use measurements in a glance
Structured use for accurate and effective operations
Very simple connections; easily accessed keys
An instrument "built for the field"
(straps, around-the-neck holder)
Measurements made in compliance with EN 50160
OBSERVE, DIAGNOSE, MONITOR...
C.A 8332C.A 8334
ThreePhase
Power QualityAnalysers
-
8/12/2019 Power Quality Analizer (Ca_8332)
2/6
Principal parameters measured:
TRM S A C +D C voltage: single voltage
up to 480 V ; phase-phase voltage up to 600 V.
TRM S AC , A C +D C current up to 3000 A
(according to sensors used).
Peak voltage and current.
Frequency from 40 to 70 H z.
A ctive, reactive and apparent pow er per phase
and their aggregate.
A ctive, reactive, consum ed and produced energy.
H arm onics for voltage, current, or pow er up
to the 50thorder.
Principal values computed:
N eutral current.
C rest factors for current and voltage.
K factors for current (transform er application).
Pow er factor, displacem ent factor and tangent.
Short-term voltage flicker.
Voltage and current unbalance.
Total harm onic distortion.
Average, m in and m ax values
of any com puted value.
Regardless of the screen, the synergy
between the display and the keyboard
is very efficient.
Additional functions:
G raphic data processing.
A larm s, transients.
Recording, dating and characteristics of
disturbances (sw ells, dips and interruptions, etc.)
D ata storage.
Im m ediate screen printout to printer.
Screen storage.
O ptical link com m unication.
Designed for Electrical Energy departments and Maintenance
services in industrial and administrative buildings, the Qualistar
C.A 8332 and C.A 8334 give an instantaneous image of the main
characteristics of the quality of your electrical network.
These instruments also provide numerous calculated values
and processing functions in compliance with standards in use
(EN 50160, IEC 61000-4-15, IEC 61000-4-30, IEC 61000-4-7).
Display mode
Horizontal cursor
Vertical cursorfor selecting phases
Date and Hour
Battery status
Pop-up menu functions;the active function stays yellow.
P R E S E N TATI O N
-
8/12/2019 Power Quality Analizer (Ca_8332)
3/6
A keyboard divided
into easily identifiable zones
Along with its high-performance measurements,the Qualistar is ergonomic and offers a user-friendly
operating mode.
Waveform Mode
F U N C T I O N S
G lobal THD and phase by phase in U, I,V, VA in % , RM S value and harm onicsphase shift.O nly the C .A 8334 m odel offers theharm onics function in VA and theexpert m ode. This m ode provides ananalysis of harm onics influence onneutral heating or rotating m achines.
Pow er /Energy Mode
"Diagnosis" stage:Harmonics Mod e
Very structured display modes
for 3 distinct stages
"Observation" stage:
In this m ode, three types of representations are possible: graphic, table, vectoral.
RM S m easurem ents in U and I. PEA K, M IN, M AX, AVG , KF, Pst, C F, phase shift, unbalance m easurem ents
This m ode displays all of the valuesrelative to the pow er and energy.The Start and Stop keys activateand deactivate the aggregate ofenergies.M easurem ents for:
W , Var, VAW h, W arh, VAhPF, DPF or cos and tan
Pop-up menus
Display modes
Cursors and validation
Direct functions
The keys, w hich are clearly identifiable
by their shapes, positioning and
pictogram , m ake m astering the instrum ent's
functions rapid and easy.
-
8/12/2019 Power Quality Analizer (Ca_8332)
4/6
C onfiguring instrum ent via softw are: setup, recording and alarm s m odes.
Recorded and alarm data processing.
G raphic representation of data in W indow sTM
environm ent.
D ata analysis in com pliance w ith EN 50160 standard.
Screen printout and transient transfers in BM P form at.
3D representation of harm onics.
D ata to spreadsheet transfer (Excel).
Input characteristics
Voltages: phase-phase: 600 V TRM Sphase-neutral: 480 V TRM S
Currents: according to sensorsM N clam p: 2 A ... 240 AC clam p: 3 A ... 1 200 AA m pFLEX: 10 A ... 3 000 APA C : 10 A ... 1 000 A A C
10 A ... 1 400 A D CA dapter unit casing for external C T
S P E C I F I C A T I O N S
General characteristics
Power supply: M ains: 110 V and 230 VN iM H (9.6 V ) rechargeable battery
Autonomy: 10 hoursTemperature for use: 0... 50CStorage temperature: - 40... 70C
Standards: EN IEC 61010, 600 V cat. III, pollution 2D ouble insulation for inputs and outputs
Dimensions (L x W x H): 180 x 55 x 240Weight: 1.5 kg w ith battery
Frequency range: 40 - 70 H zVoltage accuracy: 0.5 %
Current: 0.5 %Power: 1 %
Power factor: 0.01Frequency: 0.01 Hz
THD (total harmonic distortion): 1 % L 2 ptsEnergy: 1 % L
Sampling frequency: 12.8 kH z / channel at 50 H z
Functional characteristics
Functions C.A 8332 C.A 8334
Display color LCD 320 x 240 color LCD 320 x 240
Memory 2 M bytes 4 M bytes
Battery 1800 m Ah 3800 m Ah
Harmonics Yes Yes + expert m ode
Recording Yes (lim ited) Yes
Alarms Yes Yes
Transients No Yes
Mains AC+DC AC+DC
Digital link RS 232 RS 232
W ith the
around-the-neck
holder, m aking
m easurem ents
is easy: operating
the instrum ent and
reading the displays
at the sam e tim e.
-
8/12/2019 Power Quality Analizer (Ca_8332)
5/6
A ll desired param eters are savedw ith their visual graphics duringa recording.N ote that a bargraph locatedat the top of the w indow givesthe total recording period,program m able recording periodand storing rate.
The transient m ode captureschanges of the voltage and currentw ith triggers on thresholds.Representation over 4 periodsof the captured event at 256 counts/ period, also available w ith zoom .
Tra nsient Mo d e
"Monitoring" stage:
Alarms Mode
The sim plicity of theinstrum ent's set-up isenhanced by the use ofgraphic representations:type of clam p, connection,color of phases, param eters
to record
Q ualistar can be connecteddirectly to a printer forim m ediate screen printing.
If needed, the help keyexplains functions inrelation to the view edscreen in sim ple term s.
Press this key to m akea copy of the screen.Storing the view ed screenis autom atic w ith dateand tim e recording.U p to 12 screenrecordings (C .A 8334).
Recording Mod e
Printing
Help
The alarm s are defined duringthe instrum ent's configuration.The alarm m ode displays allthreshold events w hich occurduring the m easurem ent period.
Direct function keys:
Configuration
Screen Shot
A utom atic tim e and daterecording of the alarm ,the m axim um correspondingvalue, and the duration ofthe event.
-
8/12/2019 Power Quality Analizer (Ca_8332)
6/6
YOUR DISTRIBUTOR
TEST & MEASU REMEN T DIV ISION
FRANCE
190, rue C ham pionnet
75876 PAR IS C edex 18
Tel: +33 1 44 85 44 86
Fax: +33 1 46 27 95 59
e-m ail: exp ort@ chauvin-arnoux.fr
w w w .chauvin-arnoux.fr
UNITED KINGDOM
W aldeck H ouse - W aldeck R oad
M AIDEN HEAD SL6 8BR
Tel: 01628 788 888
Fax:01628 628 099
e-m ail: info@ chauvin-arnoux.co .uk
w w w .chauvin-arnoux.co.uk
Power Quality Analyser :
Instrum ent com es com plete (as per grid) w ith:
- 1 Q ualistarView softw are- 1 D B9F standard optical lead
- 4 x 3m leads fitted w ith banana plugs
- 4 crocodile clips
- 1 m ains lead
- User's m anual
VERSIONS (terminals colors)French (red, green, yellow , blue) F R
International (red, blue, black, w hite) I N
CURRENT SENSORS IN A SHOULDER BAGNone X X
Set of 3 C193 clam ps (1000A - dia: 52 m m ) C X
Set of 3 Am pflex A193 (3000A -dia: 140 m m / length 450 m m ) A 1
Set of 3 Am pflex A193 (3000A -dia: 250 m m / length 800 m m ) A 2
Set of 3 M N93 clam ps (240A- dia: 20 m m ) M N
Set of 3 PAC 93 clam ps (1400A - dia: 42 m m ) P A
USER'S MANUAL LANGUAGESFrench (by default) F R
English G B
G erm an A L
Italian I T
Spanish E S
Portuguese P T
2P MAINS SUPPLY LEADFrench, G erm an, or Spanish (by default) F
English G
Italian I
Sw iss C
USA U
O r:
P01160501: W ATT C.A 8332-F M N clam p P01160503: W ATT C .A 8332-Int M N clam p
P01160601: W ATT C.A 8334-F M N clam p P01160603: W ATT C .A 8334-Int M N clam p
P01160502: W ATT C.A 8332-F Am pflex (450 m m ) P01160504: W ATT C.A 8332-Int Am pflex (450 m m )
P01160602: W ATT C.A 8334-F Am pflex (450 m m ) P01160604: W ATT C.A 8334-Int Am pflex (450 m m )
ACCESSORIES:P01120327: SET O F 3 C193-F* CLAM PS P01120321: SET O F 3 C193-Int** C LA M PS
P01120422: SET O F 3 M N 93-F* C LAM PS P01120423: SET O F 3M N 93-Int** C LAM PS
P01120535: SET O F 3 AM PFLEX A 193 450 m m -F* P01120523: SET O F 3 AM PFLEX A 193 450 m m -Int**
P01120536: SET O F 3 AM PFLEX A 193 800 m m -F* P01120524: SET O F 3 AM PFLEX A 193 800 m m -Int**
P01120076: SET O F 3 PAC 93-F* CLA M PS P01120077: SET O F 3 PAC 93-Int** C LA M PS
P01101959: 5A CA833X-F* ADAPTER UNIT P01101959A: 5A CA833X-Int** ADAPTER UNIT
P01298051: SHO U LDER BAG FO R C ABLE N 6 P01298055: SHO ULDER BAG FO R INSTRUM ENT N 21
TO O R D E R
906211032-Ed.
2-VS02/2002-Characteristicssubjecttomodificationsaccordingtotechnologicaldevelopments.
C A 8 3 3 2
C A 8 3 3 4
* F = French version: Users manual in French L1 / red, L2 / green, L3 / yellow, N / blue