power optimiser - sunrise power solutions · maximum (7)power per string 11250 13500 w parallel...

PV power optimisation at the module-level The most cost effective solution for commercial and large field installations Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Balance of System cost reducon; 50% less cables, fuses and combiner boxes, over 2x longer string lengths possible Fast installaon with a single bolt Advanced maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety Use with two PV modules connected in series or in parallel POWER OPTIMISER www.solaredge.com Power Optimiser for Australia P600 / P700 / P800p / P850

Upload: others

Post on 03-Jun-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Power Optimiser - Sunrise Power Solutions · Maximum (7)Power per String 11250 13500 W Parallel Strings of Different Lengths or Orientations Yes Optimiser model (typical module compatibility)

PV power optimisation at the module-level The most cost effective solution for commercial and large field installations SpecificallydesignedtoworkwithSolarEdgeinverters Upto25%moreenergy Superiorefficiency(99.5%) BalanceofSystemcostreduction;50%lesscables,fusesandcombinerboxes,

over2xlongerstringlengthspossible Fastinstallationwithasinglebolt Advancedmaintenancewithmodule-levelmonitoring Module-levelvoltageshutdownforinstallerandfirefightersafety UsewithtwoPVmodulesconnectedinseriesorinparallel

POW

ER O

PTIM

ISER

www.solaredge.com

Power Optimiser for AustraliaP600 / P700 / P800p / P850

Page 2: Power Optimiser - Sunrise Power Solutions · Maximum (7)Power per String 11250 13500 W Parallel Strings of Different Lengths or Orientations Yes Optimiser model (typical module compatibility)

PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(4)(5) THREE PHASE SE15K THREE PHASE SE16K

AND LARGERCompatiblePowerOptimisers P600 P700(6) P600 P700 P800p P850(6)

MinimumStringLengthPowerOptimisers 13 12

PVModules 26 24

MaximumStringLengthPowerOptimisers 30

PVModules 60MaximumPowerperString 11250(7) 13500 WParallelStringsofDifferentLengthsorOrientations Yes

Optimiser model(typical module compatibility)

P600 (for 2 x 60-cell PV modules)

P700 (for 2 x 72-cell PV modules)

P800p(for parallel connection of 2x 96-cell 5’’ PV modules)

P850 (for series connection of

2x high power or bi-facial modules)

INPUTRatedInputDCPower(1) 600 730 800 850 WAbsoluteMaximumInputVoltage(Vocatlowesttemperature) 96 125 83 120 Vdc

MPPTOperatingRange 12.5-80 12.5-105 12.5-83 12.5-105 VdcMaximumShortCircuitCurrent(Isc) 10.25 11 14 12.5 AdcMaximumEfficiency 99.5 %WeightedEfficiency 98.6 %OvervoltageCategory IIOUTPUT DURING OPERATION (POWER OPTIMISER CONNECTED TO OPERATING SOLAREDGE INVERTER)MaximumOutputCurrent 15 18 AdcMaximumOutputVoltage 85 VdcOUTPUT DURING STANDBY (POWER OPTIMISER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)SafetyOutputVoltageperPowerOptimiser 1±0.1 VdcSTANDARD COMPLIANCEEMC FCCPart15ClassB,IEC61000-6-2,IEC61000-6-3Safety IEC62109-1(classIIsafety)RoHS YesFireSafety VDE-AR-E2100-712:2013-05INSTALLATION SPECIFICATIONS CompatibleSolarEdgeInverters Threephaseinverters

SE15K&largerThreephaseinverters

SE16K&largerMaximumAllowedSystemVoltage 1000 VdcDimensions(WxLxH) 128x152x43 128x152x50 128x158x59 128x152x59 mmWeight(includingcables) 834 933 1019 1064 grInputConnector(2) MC4 MC4(5) MC4OutputConnector MC4OutputWireLength 1.8 2.1 1.8 2.1 mOperatingTemperatureRange(3) -40-+85 ˚C

ProtectionRating IP68/NEMA6PRelativeHumidity 0-100 %

(1)RatedSTCpowerofthemodule.Moduleofupto+5%powertoleranceallowed.(2)ForotherconnectortypespleasecontactSolarEdge.(3)Forambienttemperatureabove+70˚C/+158˚Fpowerde-ratingisapplied.RefertoPowerOptimisersTemperatureDe-RatingApplicationNoteformoredetails.

© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein

are trademarks of their respective owners. Date: 04/2018/V01/ENG AUS. Subject to change without notice.

(4)P600andP700canbemixedinonestring.ItisnotallowedtomixP600/P700/P800p/P850withP300/P370/P500/P404/P405/P505inonestring.(5)InacaseofoddnumberofPVmodulesinonestringitisallowedtoinstalloneP600/P700/P800p/P850poweroptimiserconnectedtoonePVmodule.WhenconnectingasinglemoduletotheP800psealthe

unusedinputconnectorswiththesuppliedpairofseals.(6)Longerinputswirelength(90cm)areavailableforusewithsplitjunctionboxmodules(OrderP700-XXXLXXXorP850-XXXLXXX).(7)ForSE27.6K:Itisallowedtoinstallupto13,500Wperstringwhen3stringsareconnectedtotheinverterandwhenthemaximumpowerdifferencebetweenthestringsisupto2,000W;invertermaxDC

power:37,250W.

Power Optimiser for Australia P600 / P700 / P800p / P850