  • Power Capacitors and Capacitor BanksSelected Projects

    siemens.com/energy

    Answers for energy.

  • 2In 2009, Siemens extended its product portfolio and since then delivers High Voltage Power Capacitors and Capacitor Banks to renowned customers worldwide. These products and systems fulfill the highest electrical and mechanical requirements; they are used for the most diversified applications and can be operated under the most stringent environmental conditions.

    Siemens High Voltage Power Capacitors do not only enhance the transmission capacity or the network stability, but also contribute to economical growth and enable a significant reduction of carbon dioxide emissions.

    Capacitors for the World

    01

    06

    02

    04

    05

    03

  • 3Siemens Power Capacitor factory is located in the industrial complex in Jundia, Brazil, the largest production complex of Siemens in Latin America.

    Siemens Power Capacitor Factory

    1959 Laelc starts operations, manufacturing Power Capacitors for several projects, including Itaip HVDC, the first 600 kV HVDC of the world in the 80s.

    1979 Laelc buys the technology to manufacture internally fused capacitors

    2007 Siemens acquires from Laelc the technology to manufacture power capacitors and capacitor banks

    2009 Siemens High Voltage Power Capacitors factory starts commercial operation and was awarded its first large HVDC order for India

    2013 Siemens High Voltage Power Capacitors are globally present in several countries around the world with a product portfolio for all types of application

    History 50 Years of Experience

    Selected Projects Page

    01 HVDC Adani India 5

    02 HVDC Estlink 2 Finland & Estonia 6

    03 FSC Tucuru-Manaus Brazil 7

    04 MSCDN Lincs Wind Farm UK 8

    05 HVDC Hudson USA 9

    06 HVDC Black Sea Georgia 10

    07 Other selected projects 11

    High Voltage Power Capacitor Factory

    Other selected projects

  • 4Power Capacitors Technical Data

    Flexible AC Transmission Systems (FACTS)

    Parallel Compensation

    Static Var Compensator (SVC)

    Mechanically Switched Capacitor with Damping Network (MSCDN)

    Mechanically Switched Capacitors (MSC)

    Series Compensation

    Thyristor Controlled Series Compensation (TCSC)

    Thyristor Protected Series Compensation (TPSC)

    Fixed Series Compensation (FSC)

    AC Harmonic Filters

    AC PLC Filters

    Long Distance and Back-to-Back HVDC AC & DC Filters

    AC & DC Surge Capacitors

    Capacitor Banks Applications

    Capacitor Unit Design

    Technology Internally fused, externally fused, fuseless, and unfused

    Rated voltage With internal fuses: 15 kVWithout internal fuses: 24 kV

    Frequency 50 Hz/60 Hz

    Rated power Up to 1000 kvar (50 Hz) Up to 1200 kvar (60 Hz)

    Current Max. 180 A

    BIL 95 kV, 125 kV, 150 kV, 170 kV, 200 kV

    Dielectric Polypropylene film and oil

    Impregnant Biodegradable PCB-free oil

    Discharge resistor 75 V/10 min or 50 V/5 min

    Losses With internal fuses: < 0.20 W/kvarWithout internal fuses: < 0.12 W/kvar

    Temperature range -50/+55 C

    Standards IEC, IEEE, ABNT, CSA, and others

    Quality certificates ISO 9001; ISO 14001; OHSAS 18001

    Final figures to be confirmed during projectFor other standards please consult the factory

    Siemens entered the Power Capacitor market with a product for the most diversified applications. Long-term reliable technology and intensive R&D investments lead to a state-of-the-art product, compliant with the most stringent technical and environmental requirements,

    including extremely low temperatures (like -50 C in northern Canada), extremely high temperatures (like +50 C in India), high humidity (like in the rainforests of northern Brazil) and the most extreme seismic zones (like in New Zealand).

  • 5The HVDC system operated by Adani Power Ltd. has a transmission capacity of 2500 MW and provides low-loss energy transmission over a distance of approximately 960 km, from the port of Mundra located on the west coast to the industrial regions in the Haryana state.The AC filters for this HVDC system represent the first

    HVDC Adani India

    Technical DataLocations Mundra and Mohindergarh S/S

    Total rated power 3.7 Gvar

    Unit output 815.6 to 852.0 kvar

    Bank voltages 280.3 to 294.8 kV

    Rated unit voltages 7.8 to 9.7 kV

    Quantity of units 4,840

    Technology Internally fused

    Supply date August 2010

    Temperature category -5 /+50 C

    large order for the capacitor factory in Jundia, which delivered the first units to India only 6 months after the official inauguration in December 2009. The total installed output of the 54 single phase high voltage AC filters was close to 4000 Mvar and the total number of units supplied was 4840 (including spare parts).

  • 6HVDC Estlink 2 Finland & Estonia

    Technical DataLocations Anttila and Puessi substations

    Total rated power 1.17 Gvar

    Unit output 113 to 849 kvar

    Bank voltages 6.1 to 325.5 kV

    Rated unit voltages 3.0 to 19.2 kV

    Quantity of units 1,878

    Technology Internally fused, fuseless and unfused

    Supply date August 2012

    Temperature category -40/+40 C

    In December 2010 Fingrid and Elering awarded the contract for the Estlink 2 Converter Stations to Siemens, using a HVDC Transmission System with a transmission capacity of 650 megawatts at a DC voltage of 450 kilovolts.

    The Siemens capacitor factory in Brazil supplied a total of 24 single phase high voltage AC filter banks (C1-type) using internally fused and fuseless technology and 36 single phase medium voltage AC filter banks (C2/C3-type unfused technology).

  • 7FSC Tucuru-Manaus Brazil

    Siemens Ltda. Brazil was awarded the FACTS systems for the 1800 km long 500 kV HV transmission system connecting the Tucuru Hydro Power Plant with the city of Manaus in 2010. The scope of supply included a total of 18 Fixed Series capacitors located at 5 different sub-stations in the Amazon forest.

    Technical DataLocations 5 substations along the trans-

    mission line Tucuru-Manaus

    Total rated power 6.8 Gvar

    Unit output 743.8 to 825.4 kvar

    Bank voltage 500 kV

    Rated unit voltages 6.3 to 7.1 kV

    Quantity of units 8,496

    Technology Internally fused

    Supply date 2010 2012

    Temperature category -5/+50 C

    The Capacitor factory in Jundia was responsible for the supply of all the capacitors of this project, considered to be the largest FACTS project ever executed worldwide.

  • 8MSCDN Lincs Wind Farm UK

    Technical DataLocation Walpole substation, England

    Total Rated Power 392 Mvar

    Unit output 180 to 867 kvar

    Bank voltage 132 and 13.9 kV

    Rated unit voltages 4.3 to 11.8 kV

    Total units 576

    Technology Internally fused and fuseless

    Supply date April 2011

    Temperature cat. -25/+40 C

    The Lincs project, owned by Lincs Wind farm Limited is located in the Greater Wash wind farm park, England and will generate capacity of 270 MW. The energy generated offshore is transferred to the grid via the Walpole onshore substation located in the Norfolk County. Siemens Trans-mission and Distribution Ltd., UK was awarded with the construction of the entire onshore substation in 2010.

    The Siemens High Voltage capacitor plant has provided a total of 6 single phase Capacitor Banks for the 132 kV-MSCDN comprising fuseless C1 and C2-banks with a total installed rating of 246,3 Mvar, as well as 6 single phase banks with internally fused capacitors for the 13.9 kV CMSC with a total output of 145.7 Mvar.

  • 9HVDC Hudson USA

    Technical DataLocations West 49th Street and Bergen

    Total Rated Power 1.3 Gvar

    Unit output 122 to 1019 kvar

    Bank voltages 8.4 to 244.7 kV

    Rated unit voltages 7.2 to 17.7 kV

    Total units 1,524

    Technology Internally fused and unfused

    Supply date May 2012

    Temperature category -30/+40 C

    In May 2011 Hudson Transmission Partners, LLC awarded the contract to Siemens to connect the power supply net-works of New Jersey and New York, USA using a 660 MW back-to-back HVDC system will contribute to the stabiliza-tion of the connected systems, a key benefit in the event of grid disturbances or blackouts.

    The capacitor plant in Brazil supplied 18 single phase High Voltage AC Filter banks (internally fused technology) and 36 single phase Medium voltage AC Filter banks (C2/C3 and C4-type, unfused technology) for this HVDC system, providing unit outputs larger than 1.0 Mvar for the first time.

  • 10

    HVDC Black Sea Georgia

    Technical DataLocation Akhaltsikhe substation

    Total rated power 1.266 Gvar

    Unit output 220 to 722 kvar

    Bank voltages 60.7 to 354.6 kV

    Rated unit voltages 9.3 to 18 kV

    Quantity of units 2,237

    Technology Internally fused & unfused

    Supply date August 2011

    Temperature category -25/+50 C

    In August 2010 Energotrans Ltd. awarded the contract to Siemens for 350 MW back-to-back HVDC systems in Georgia. The HVDC converter station will connect the networks of Georgia and Turkey via two back-to-back links.

    The capacitor plant in Brazil supplied 27 single phase High Voltage AC Filter banks (internally fused technol-ogy) and 36 single phase Medium voltage AC Filter banks (C2 and C3-type, unfused technology) for this HVDC system located at an altitude of 1,100 meters above sea level in a seismic region.

  • 11

    ProjectCustomer/ Country/ Year

    Scope Technical Data Highlight/ Technology

    HVDC WATL AltaLinkCanada2013

    36 x HV single phase AC filter banks; 60 x MV single phase AC filter banks; 6 x HV single phase shunt banks

    Total rated power 3,045 Mvar Very low temperature -50 C, internally fused and unfused capacitors

    Unit output 122.9 to 993.5 kvar

    Bank voltage 5.73 to 440.61 kV

    Unit voltage 5.73 to 17.06 kV

    Quantity of units 3,744

    MSCDN 400 kV RTE France2013

    17 x MSCDN (Type 150 Mvar 380 kV)

    Total rated power 5,665 Mvar Largest MSCDN project ever awarded to Siemens, Internally fused

    Unit output 593.2 to 886.2 kvar

    Bank voltage 24.39 to 553.91 kV

    Unit voltage 7.04 to 10.66kV

    Quantity of units 6,528

    HVDC ATCO ATCO Electric Canada2013

    36 x HV single phase AC filter banks; 60 x MV single phase AC filter banks; 12 x HV single phase shunt banks

    Total rated power 2,462 Mvar Very low temperature -50 C, internally fused and unfused capacitors

    Unit output 126.1 to 963.2 kvar

    Bank voltage 8.86 to 376 kV

    Unit voltage 5.58 to 18.25 kV

    Quantity of units 3,558

    SVC Diego de Almagro

    TranselecChile 2013

    1 x MSC (Type 75.64 Mvar 12.27 kV)

    Total rated power 75.64 Mvar High seismic conditions, internally fused

    Unit output 900.5 kvar

    Bank voltage 12.27 kV

    Unit voltage 6.133 kV

    Quantity of units 84

    Harker, Hutton and Stella400 kV MSCDN

    National GridUnited Kingdom 2013

    5 x MSCDN (Type 225 Mvar 400 kV)

    Total rated power 1,459 Mvar Low temperature -25 C, internally fused

    Unit output 719.8 and 825.1 kvar

    Bank voltage 244 kV and 31.7 kV

    Unit voltage 7.925 and 9.403 kV

    Quantity of units 1,800

    MSCDN Gwynt Y Mor

    RWEUnited Kingdom2012

    6 x 132 kV filter banks; 4 x 13.9 MSC banks

    Total rated power 495 Mvar Internally fused and fuseless capacitors

    Unit output 212.6 to 875.5 kvar

    Bank voltage 6.735 to 98.05 kV

    Unit voltage 6.735 to 12.256 kV

    Quantity of units 642

    SVC Bout de Llle Hydro QuebecCanada2013

    2 x three-phase single tuned filter banks; 2 x three-phase TSC-banks

    Total rated power 1,400 Mvar Low temperature -40 C, internally fused, high seismic requirements

    Unit output 922 to 934 kvar

    Bank voltage 28 to 36.5 kV

    Unit voltage 7.1 to 9.1 kV

    Quantity of units 1,602

    SVC Gerdau Diaco Diaco S.A.Colombia2012

    3 x three-phase filter circuits Total rated power 118.5 Mvar Industrial electric arc furnace application, internally fused

    Unit output 584.4 to 1091.5 kvar

    Bank voltage 7 to 20.8 kV

    Unit voltage 4.04 to 12 kV

    Quantity of units 180

    SVC Horqueta AndeParaguay2011

    3 x three-phase single tuned filter banks; 2 x three-phase TSC-banks

    Total rated power 265 Mvar Internally fusedUnit output 727.58 to 783.44 kvar

    Bank voltage 17.7 to 21.42 kV

    Unit voltage 5.57 to 6.18 kV

    Quantity of units 350

    HVDC Kontek Energinet Denmark2011

    1 x three-phase HV filter (282 kV); 2 x three-phase MV filter banks

    Total rated power 96.7 Mvar Noise reduced with exter-nal noise damping hoods, internally fused and unfused capacitors

    Unit output 643/435/427 kvar

    Bank voltage 282 kV

    Unit voltage 20.7 / 17.2 / 19.2 kV

    Quantity of units 157

    MSC London Array Windfarm

    London ArrayUnited Kingdom2011

    4 x MSCDN (Type 150 kV)

    Total rated power 156.2 Mvar Fuseless capacitorsUnit output 360.5 / 370.2 kvar

    Bank voltage 150 kV

    Unit voltage 14.2 / 4.16 kV

    Quantity of units 445

    HVDC Cookstraight, Pole 3

    TranspowerNew Zealand2011

    27 x HV single phase AC filter banks; 27 x MV single phase AC filter banks; 3 x HV single phase shunt banks

    Total rated power 1,165 Mvar Very high seismic require-ments, internally fused and unfused capacitors

    Unit output 270 to 833 kvar

    Bank voltage 257 to 348 kV

    Unit voltage 9.1 to 13.7 kV

    Quantity of units 1,690

    MSC S/S J Paran, S/S Vilhena

    ELETRONORTEBrazil2010

    4 x MSC (Type 20.52 Mvar 242 kV)

    Total rated power 82.1 Mvar First fuseless applicationUnit output 570 kvar

    Bank voltage 242 kV

    Unit voltage 11.646 kV

    Quantity of units 144

    SVC Bom Jesus da Lapa II

    TAESABrazil2010

    Filter I and Filter II for SVC Total rated power 42 + 66 Mvar First SVC application, internally fused

    Unit output 786 kvar / 916.3 kvar

    Bank voltage 23.16 kV / 21.46 kV

    Unit voltage 13.369 kV /12.389 kV

    Quantity of units 54 / 72

    MSC ANDE Paraguay

    RIEDER & CIA/CLYFSAParaguay2009

    1 x MSC (Type 12 Mvar 24 kV)

    Total rated power 12 Mvar First capacitor bank delivery, internally fused

    Unit output 500 kvar

    Bank voltage 24 kV

    Unit voltage 13.2 kV

    Quantity of units 24

  • Published by and copyright 2013: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany

    Siemens AGEnergy SectorPower Transmission DivisionTransmission SolutionsFreyeslebenstrasse 191058 Erlangen, Germanywww.energy.siemens.com/hq/en/power-transmission/high-voltage-products/capacitors.htm

    For more information, please contact Siemens Ltda., E T TS TI 3 CA Av. Eng. Joo F.G. Molina 1745 13213-080 Jundia SP Brazil Phone: +55 11 4585 2303 +55 11 4585 3150

    For more information, please contact our Customer Support Center. Phone: +49 180/524 70 00 Fax: +49 180/524 24 71 (Charges depending on provider)E-mail: [email protected]

    Power Transmission Division Order No. E50001-G610-A130-V1-4A00 | Printed in Germany | Dispo 30003 | c4bs No. 7495 | TH 150-130701 | W | 473222 | WS | 09131.0

    Printed on elementary chlorine-free bleached paper.

    All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners.

    Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.