Wiring Diagram: Reader O-1-S Populus V9 S with www.jantar.si Use 12V DC el. strike only! Check the polarity (+ -)! An improperly connected el. strike can permanently damage Populus! The power consumption of el. strike must not exceed 250mA! El. strike Reader O-1-S CONNECTION CABLE Wire Colour Description Populus connector 1 Red 9-14V DC RDR - 12V 2 Gray GND RDR - GND 3 Light blue Rs485 - CA RDR - XA 4 Brown Rs485 - CB RDR - XB UTP cable up to 200m, see manual + - Backup battery, 12V 2.3Ah. Pay attention to the polarity! El. Strike Relay Door status switch El. strike power Relay contact, normally open and normally close contact. Maximum current: 5A @ 230V. Initiates together with el. strike output. NC NO * 1. wire is coloured red 1. wire 4. wire Ethernet connection 110 - 230V AC Reader O-1-S Push button Push button To local area network RS 485 line to communication converter

Upload: others

Post on 02-Mar-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Populus V9 S with Reader O-1-S ENG - Jantar V9 S... · 2016. 10. 20. · Wiring Diagram:Populus V9 S with Reader O-1-S Use 12V DC el. strike only! Check the polarity (+ -)! An improperly

Wiring Diagram: Reader O-1-SPopulus V9 S with

www.jantar.si

Use 12V DC el. strike only!

Check the polarity (+ -)! An improperly connected el. strike can permanently damage Populus!

The power consumption of el. strike must not exceed 250mA!

El. strike

Reader O-1-S

CONNECTION CABLE

Wire Colour Description Populus connector

1 Red 9-14V DC RDR - 12V

2 Gray GND RDR - GND

3 Light blue Rs485 - CA RDR - XA

4 Brown Rs485 - CB RDR - XB

UTP cable up to 200m, see manual

+-

Backup battery, 12V 2.3Ah.Pay attention to the polarity!

El. Strike

Relay

Door status switch

El. strike powerRelay contact, normally open and normally close contact. Maximum current: 5A @ 230V.Initiates together with el. strike output.

NC

NO

* 1. wire is coloured red

1. wire

4. wire

Ethernet connection

110 - 230V AC

Reader O-1-S

Push button

Push button

To local area network