pn 10457 hex key 2.5mm short arm (for m3 screws) 10563 nikon... · pn 10457 hex key 2.5mm short arm...

9
1 1 2 2 3 3 4 4 A A B B REV SHEET OF PN 10563 Nikon Alphaphot Assembly Instructions 1 9 4 Wayne Bonin 3/23/2019 Parts included but not shown: PN 10457 Hex Key 2.5mm short arm (for M3 screws) Nikon Alphaphot Pot Bracket (save from microscope) PN 10351 Pot-Cable Assy (15 in cable) PN 10560 Nikon Alphaphot Illuminator Assy PN 10561 19mm long x 5mm hex standoff (2 pcs) PN 10348 SHCS M3 x 0.5 x 8mm (2 pcs) Pot Knob (save from microscope) Nanodyne Replacement Illuminator for Nikon Alphaphot Microscope Installation Instructions - Included Items Copyright 2019 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. www.nano-dyne.com Wayne Bonin 651-323-8592 3M VHB tape to secure wires Power supplies are subject to substitution without notice due to availability issues and changes in regulations. The illuminator may be powered by plugging the cable into the power supply provided, or into a suitable USB port on a computer or other device. PN 10733 Power Supply - XP Power 5V 1A and PN 10734 Cable Assy 1.35mm ID x 3.5mm OD RA plug to USB A, 6 foot.

Upload: others

Post on 24-Sep-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PN 10457 Hex Key 2.5mm short arm (for M3 screws) 10563 Nikon... · PN 10457 Hex Key 2.5mm short arm (for M3 screws) Nikon Alphaphot Pot Bracket (save from microscope) PN 10351 Pot-Cable

1

1

2

2

3

3

4

4

A A

B B

REV

SHEETOF

PN 10563 Nikon Alphaphot

Assembly Instructions

1 9

4

Wayne Bonin

3/23/2019

Parts included but not shown:

PN 10457 Hex Key 2.5mm short arm

(for M3 screws)

Nikon Alphaphot Pot Bracket

(save from microscope)

PN 10351 Pot-Cable Assy

(15 in cable)

PN 10560 Nikon Alphaphot

Illuminator Assy

PN 10561 19mm long x 5mm

hex standoff (2 pcs)

PN 10348 SHCS M3 x 0.5 x 8mm (2 pcs)

Pot Knob (save

from microscope)

Nanodyne Replacement Illuminator for Nikon Alphaphot Microscope Installation Instructions - Included Items

© Copyright 2019 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. www.nano-dyne.com Wayne Bonin 651-323-8592

3M VHB tape to secure wires

Power supplies are subject to

substitution without notice due to

availability issues and changes in

regulations.

The illuminator may be powered by

plugging the cable into the power

supply provided, or into a suitable

USB port on a computer or other

device.

PN 10733 Power Supply - XP

Power 5V 1A and PN 10734 Cable

Assy 1.35mm ID x 3.5mm OD RA

plug to USB A, 6 foot.

Page 2: PN 10457 Hex Key 2.5mm short arm (for M3 screws) 10563 Nikon... · PN 10457 Hex Key 2.5mm short arm (for M3 screws) Nikon Alphaphot Pot Bracket (save from microscope) PN 10351 Pot-Cable

1

1

2

2

3

3

4

4

A A

B B

REV

SHEETOF

PN 10563 Nikon Alphaphot

Assembly Instructions

2 9

4

Wayne Bonin

3/23/2019

Begin by removing the condenser lens with a twist as shown above and below.

On the underside of the microscope, locate the

housing for the light bulb and remove it.

Nanodyne Replacement Illuminator for Nikon Alphaphot Microscope Installation Instructions - Step 1. Remove condenser lens and old lamp housing.

© Copyright 2019 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. www.nano-dyne.com Wayne Bonin 651-323-8592

Photo 1a

Photo 1b

Photo 1c

Page 3: PN 10457 Hex Key 2.5mm short arm (for M3 screws) 10563 Nikon... · PN 10457 Hex Key 2.5mm short arm (for M3 screws) Nikon Alphaphot Pot Bracket (save from microscope) PN 10351 Pot-Cable

1

1

2

2

3

3

4

4

A A

B B

REV

SHEETOF

PN 10563 Nikon Alphaphot

Assembly Instructions

3 9

4

Wayne Bonin

3/23/2019

Remove the lighting unit by unscrewing the four screws that hold it in place.

Nanodyne Replacement Illuminator for Nikon Alphaphot Microscope Installation Instructions - Step 2. Remove old lamp.

© Copyright 2019 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. www.nano-dyne.com Wayne Bonin 651-323-8592

Photo 2a

Page 4: PN 10457 Hex Key 2.5mm short arm (for M3 screws) 10563 Nikon... · PN 10457 Hex Key 2.5mm short arm (for M3 screws) Nikon Alphaphot Pot Bracket (save from microscope) PN 10351 Pot-Cable

1

1

2

2

3

3

4

4

A A

B B

REV

SHEETOF

PN 10563 Nikon Alphaphot

Assembly Instructions

4 9

4

Wayne Bonin

3/23/2019

Remove the items shown from the

lighting unit. These items include

the bulb, metal lighting bracket,

potentiometer and electronics, and

light socket.

Nanodyne Replacement Illuminator for Nikon Alphaphot Microscope Installation Instructions - Step 3. Remove old parts (bulb, bracket, pot and socket).

© Copyright 2019 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. www.nano-dyne.com Wayne Bonin 651-323-8592

Photo 3a

Photo 3b

Photo 3c

Page 5: PN 10457 Hex Key 2.5mm short arm (for M3 screws) 10563 Nikon... · PN 10457 Hex Key 2.5mm short arm (for M3 screws) Nikon Alphaphot Pot Bracket (save from microscope) PN 10351 Pot-Cable

1

1

2

2

3

3

4

4

A A

B B

REV

SHEETOF

PN 10563 Nikon Alphaphot

Assembly Instructions

5 9

4

Wayne Bonin

3/23/2019

Disconnect the potentiometer knob and bracket using a 10mm socket, as shown above. Keep these components for later.

Nanodyne Replacement Illuminator for Nikon Alphaphot Microscope Installation Instructions - Step 4. Remove pot knob and bracket.

© Copyright 2019 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. www.nano-dyne.com Wayne Bonin 651-323-8592

Photo 4a

Photo 4b

Page 6: PN 10457 Hex Key 2.5mm short arm (for M3 screws) 10563 Nikon... · PN 10457 Hex Key 2.5mm short arm (for M3 screws) Nikon Alphaphot Pot Bracket (save from microscope) PN 10351 Pot-Cable

1

1

2

2

3

3

4

4

A A

B B

REV

SHEETOF

PN 10563 Nikon Alphaphot

Assembly Instructions

6 9

4

Wayne Bonin

3/23/2019

Place the new potentiometer onto the existing bracket and screw in place. Then, install the

existing knob onto the new potentiometer. Route the cable through the light socket hole, as

shown.

Route the new power cord through the

existing power cord hole, and through the

light socket hole. Seat the provided

grommet in the existing power cord hole.

Nanodyne Replacement Illuminator for Nikon Alphaphot Microscope Installation Instructions - Step 5. Install new pot and power cord.

© Copyright 2019 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. www.nano-dyne.com Wayne Bonin 651-323-8592

Photo 5a

Photo 5b

Photo 5c

Photo 5d

Page 7: PN 10457 Hex Key 2.5mm short arm (for M3 screws) 10563 Nikon... · PN 10457 Hex Key 2.5mm short arm (for M3 screws) Nikon Alphaphot Pot Bracket (save from microscope) PN 10351 Pot-Cable

1

1

2

2

3

3

4

4

A A

B B

REV

SHEETOF

PN 10563 Nikon Alphaphot

Assembly Instructions

7 9

4

Wayne Bonin

3/23/2019

Thread the hex standoffs into the holes, as shown above. Do not tighten them all the way, as some play is

needed in order to re-insert the condenser lens.

Hex Standoff

Re-install the condensing lens and then fully tighten the hex standoffs.

Nanodyne Replacement Illuminator for Nikon Alphaphot Microscope Installation Instructions - Step 6. Install hex standoffs and condenser lens.

© Copyright 2019 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. www.nano-dyne.com Wayne Bonin 651-323-8592

Photo 6aPhoto 6b

Page 8: PN 10457 Hex Key 2.5mm short arm (for M3 screws) 10563 Nikon... · PN 10457 Hex Key 2.5mm short arm (for M3 screws) Nikon Alphaphot Pot Bracket (save from microscope) PN 10351 Pot-Cable

1

1

2

2

3

3

4

4

A A

B B

REV

SHEETOF

PN 10563 Nikon Alphaphot

Assembly Instructions

8 9

4

Wayne Bonin

3/23/2019

Install the light assembly by inserting and tightening the provided screws, as shown.

Install these screws.

Plug the power supply into the lighting unit, as shown. Also, connect the cable from the potentiometer to the

socket on the circuit board. The connector will only seat one way, so do not force it in if it does not fit.

Nanodyne Replacement Illuminator for Nikon Alphaphot Microscope Installation Instructions - Step 7. Install Nanodyne illuminator.

© Copyright 2019 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. www.nano-dyne.com Wayne Bonin 651-323-8592

Photo 7aPhoto 7b

Page 9: PN 10457 Hex Key 2.5mm short arm (for M3 screws) 10563 Nikon... · PN 10457 Hex Key 2.5mm short arm (for M3 screws) Nikon Alphaphot Pot Bracket (save from microscope) PN 10351 Pot-Cable

1

1

2

2

3

3

4

4

A A

B B

REV

SHEETOF

PN 10563 Nikon Alphaphot

Assembly Instructions

9 9

4

Wayne Bonin

3/23/2019

Re-install the light cover on the bottom of the microscope, plug in the power supply, and the installation is complete.

Nanodyne Replacement Illuminator for Nikon Alphaphot Microscope Installation Instructions - Step 8. Re-install light cover and connect new power supply.

© Copyright 2019 Nanodyne Measurement Systems. Document authorized for installation of Nanodyne equipment only. www.nano-dyne.com Wayne Bonin 651-323-8592

Photo 8a