    2/10C ECRD Publications

    Measurement of ParticulatePollutants in Ambient Air

    Initial approach measured the TotalSuspended Particulate Matter (TSP)

    Much of the TSP would not enter thenose or be retained in the upper

    respiratory tract. This led to thedevelopment of PM10 samplers.

    It is now believed that most of thehealth impacts are related to Fine

    Particles that reach deep into the lungsleading to development of Fine Particleor PM2.5 Samplers.

  • 8/2/2019 PM10 Measmnt

    3/10C ECRD Publications

    Measurement of ParticulatesFeatures of the Indian

    approach Separation of Respirable fraction

    through a Cyclone leads to:

    a very compact instrument as compared to

    the bulky Impactor based systems adoptedby the West.

    Recovery of the coarse fraction allowingmeasurement of both TSP & RSP in thesame equipment.

    Adoption of Sampling systems insteadof sensor based - direct reading sys:

    Keeps costs affordable

    Simpler equipment is easier to maintain

    Minimal requirement of Calibration &

    support infrastructure. Physical sample becomes available for

    analysis of constituents

    Use of Indigenous equipment ensuresavailability of Service Support

  • 8/2/2019 PM10 Measmnt

    4/10C ECRD Publications

    Evolution of the RDS

    First developed in 1990-91 Two stage system for separation of

    coarse and fine fractions, developed

    in collaboration with NEERI.

    Envirotech introduced the RDSalmost 4 years before RSPM wasincluded in the Ambient Air QualityStandards in India.

    Initially introduced as APM451 andlater upgraded to APM460.

    Today Envirotech produces three

    variants of the RDS:

    APM460BL

    APM460NL

    APM460NLDX

  • 8/2/2019 PM10 Measmnt

    5/10C ECRD Publications

    The Improved RDSEnvirotech APM 460BL

    Brushless Blower

    Sampling rate does not fluctuatewith variation in mains voltage.

    Low equipment downtime andmaintenance costs.

    Interference to TVs eliminatedand Audible Noise reduced to

    less than half of previous levels. Castor Wheels added

    for easier movement of theinstrument in the field.

    Small bulb provided for easier

    handling at night.

  • 8/2/2019 PM10 Measmnt

    6/10C ECRD Publications

    Envirotech APM 460NL

    For Research & Intensive use Practically NOISE-LESSoperation

    of the APM 460NL makes it ideal formonitoring air quality in residential

    areas or near hospitals, libraries etc. Main features of the APM 460NL

    Sampling rate does not fluctuatewith variation in mains voltage.

    Brushless Blower designed fortrouble free operation even withintensive use.

    No interference to TVs.

    Low equipment downtime andmaintenance costs.

    However the equipment is heavyand frequent re-location should beavoided.

  • 8/2/2019 PM10 Measmnt

    7/10C ECRD Publications

    Envirotech APM 460NLDX

    Main Features:Flow rate

    automaticallycontrolled tocompensate for Dustloading on the filter.

    Auto Shut-off if flowrate drops below0.85m3/min.

    Only instrument thatconforms to BIS

    Low Noise and

    Brushless Blower

  • 8/2/2019 PM10 Measmnt

    8/10C ECRD Publications

    Monitoring Particulates inAmbient Air - Procedure &

    Precautions Preparation

    Inspect the filter for pinholes,particles and imperfections. Assignfilter identification numbers.

    Establish a system of filter batchnumbers & look-out for fakes.

    Equilibrate each filter for at least 24

    hrs. in a controlled environmenthaving:

    Temperature 15 - 30 degrees C

    Humidity 20-45%

    Weigh each filter & record the initialweight. For HVS / RDS balance with0.1mg accuracy is required.

    For low / medium volume samplers(flow rate

  • 8/2/2019 PM10 Measmnt

    9/10C ECRD Publications

    Monitoring Particulates inAmbient Air - Procedure &

    Precautions Operation

    Install pre-weighed filter, set thetimer, record Time-totalizer reading

    and turn ON the sampler flow.

    Allow it to establish normal runningtemperature and record flow rate.

    If sampling rate is outside

    acceptable limits check for leaks,filter displacement etc.

    Record sample information - sitelocation, Sample date, Filter ID No.

    On completion of sampling periodrecord flow rate and time-totalizerreading.

    Carefully remove the filter - touchonly outer edges, and store in an

    appropriate carrier.

  • 8/2/2019 PM10 Measmnt

    10/10

    Monitoring Particulates inAmbient Air - Procedure &

    Precautions

    Post Operation

    Work out the average flow rate.

    Record any factors such asmeteorological conditions,construction activity, dust storm etc.that might affect your results.

    Transport the filter to the

    equilibrating environment as soonas possible.

    Equilibrate the filter under the sameconditions for at least 24 hours.

    Immediately after equilibrationweigh and record the post sampling

    filter weight along with filter ID No.