plumbing - legend, notes and specifications€¦ · per plumbing and drainage institute standard...

1
Drawing Number: Date: Job No.: Dwn By: Chkd. By: Revisions: No. Date Description Building: Consultant: COPYRIGHT - All reports, plans, specifications, computer files, field data, notes and other documents are instruments of service prepared by Sharp Architecture, LLC shall remain the property of Sharp Architecture, LLC. Sharp Architecture, LLC shall retain all common law, statuatory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from Sharp Architecture, LLC is a violation of Federal copyright laws. 2886 Aloma Oaks Drive Oviedo, Florida 32765 (407) 346-2873 Fl. Lic # AA26002910 SHARP ARCHITECTURE, LLC Iglesia El Shaddai - 8703 Curry Ford Rd. Orlando, Florida 12.16.16 60101 6001 Brick Court, Suite 201 Winter Park, FL 32792 (407)-756-8239 Certificate #28618 © Copyright 2017 MEP Design Engineering, Inc. All Rights Reserved. D E SIGN ENGINEERING, INC. P M www.mepdesigneng.com SUSTAINABLE DESIGN & ENERGY MANAGEMENT SOLUTIONS ALL WORK TO COMPLY WITH WITH THE 2014 FLORIDA BUILDING CODE PLUMBING PLUMBING GENERAL NOTES P000 Plumbing - Legend, Notes and Specifications MV NAA

Upload: dangtuong

Post on 06-Sep-2018

247 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Plumbing - Legend, Notes and Specifications€¦ · per plumbing and drainage institute standard p.d.i. wh-201. acceptable manufacturers zurn, josam, sioux . ... c. equipment specifications

Drawing Number:

Date:

Job N

o.:

Dw

n B

y:

Chkd. B

y:

Revisions:

No.

Date

Description

Building:

Consultant:

C

OP

YR

IG

HT

- A

ll re

po

rts, p

la

ns, sp

ecifica

tio

ns, co

mp

ute

r file

s, fie

ld

d

ata

, n

ote

s a

nd

o

th

er d

ocu

me

nts a

re

in

stru

me

nts o

f se

rvice

p

re

pa

re

d b

y S

ha

rp

A

rch

ite

ctu

re

, L

LC

sh

all re

ma

in

th

e p

ro

pe

rty o

f S

ha

rp

A

rch

ite

ctu

re

, L

LC

. S

ha

rp

A

rch

ite

ctu

re

, L

LC

sh

all re

ta

in

a

ll co

mm

on

la

w, sta

tu

ato

ry a

nd

o

th

er re

se

rve

d rig

hts, in

clu

din

g th

e co

pyrig

ht th

ere

to

. A

ny u

se

o

r re

pro

du

ctio

n o

f th

is d

ocu

me

nt w

ith

ou

t w

ritte

n

pe

rm

issio

n fro

m S

ha

rp

A

rch

ite

ctu

re

, L

LC

is a

vio

la

tio

n o

f F

ed

era

l co

pyrig

ht la

ws.

2886 A

lom

a O

aks D

rive

Oviedo, F

lorida 32765

(407) 346-2873

Fl. Lic # A

A26002910

SHA

RP

ARCH

ITEC

TURE

, LLC

Igles

ia El

Sha

ddai

- 8703

Cur

ry Fo

rd R

d.Or

lando

, Flor

ida

12.16.16

60101

6001 B

rick C

ourt, S

uite 201

Winter P

ark, F

L 32792

(407)-756-8239

Certificate #28618

© C

opyri

ght 2

017 M

EP D

esign

Eng

ineer

ing, In

c.Al

l Righ

ts Re

serve

d.

D

ES

IG

N E

NG

IN

EE

RIN

G, IN

C.

P

M

ww

w.m

epdesigneng.com

SU

ST

AIN

AB

LE

D

ES

IG

N &

E

NE

RG

Y M

AN

AG

EM

EN

T S

OLU

TIO

NS

ALL WORK TO COMPLY WITH

WITH THE 2014 FLORIDA

BUILDING CODE PLUMBING

PLUMBING GENERAL NOTES

P000

Plum

bing - Legend, N

otes and S

pecifications

M

V

N

AA

AutoCAD SHX Text
A
AutoCAD SHX Text
C
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
INSTALL WATER HAMMER SHOCK ARRESTORS AT EACH FIXTURE
AutoCAD SHX Text
OR BATTERY OF FIXTURES WHERE REQUIRED. ARRESTORS
AutoCAD SHX Text
SHALL BE FACTORY FABRICATED. INSTALL ARRESTORS AND SIZE
AutoCAD SHX Text
PER PLUMBING AND DRAINAGE INSTITUTE STANDARD P.D.I.
AutoCAD SHX Text
WH-201. ACCEPTABLE MANUFACTURERS ZURN, JOSAM, SIOUX
AutoCAD SHX Text
CHIEF. PPP INC. FOR 1-11 FU'S PROVIDE PDI-A, FOR 12-32
AutoCAD SHX Text
FU'S PDI-B, 33-60 FU'S PDI-C, 61-113 FU'S PDI-D.
AutoCAD SHX Text
O.
AutoCAD SHX Text
CONNECTION TO NEW WORK TO ENSURE PROPER SLOPE AND COVER.
AutoCAD SHX Text
ADDENDUM SHALL BE BINDING. NO BIDDER SHALL RELY UPON
AutoCAD SHX Text
D. NATIONAL ELECTRIC CODE 2011 EDITION.
AutoCAD SHX Text
2.1 PIPE HANGERS AND SUPPORTS
AutoCAD SHX Text
PART 2 PRODUCTS
AutoCAD SHX Text
A. MANUFACTURERS:
AutoCAD SHX Text
APPROVAL OF ANY SUBSTITUTION FROM THE ENGINEER PRIOR TO
AutoCAD SHX Text
1.3 REGULATORY REQUIREMENTS
AutoCAD SHX Text
FORM WHICH ARE PRIOR APPROVED BY THE ENGINEER WILL BE
AutoCAD SHX Text
INCORPORATED INTO THE CONTRACT WITH THE SUCCESSFUL
AutoCAD SHX Text
AND APPROVED IN ACCORDANCE WITH THE ABOVE INSTRUCTIONS
AutoCAD SHX Text
REGULATIONS OF THE GOVERNMENTAL BODIES HAVING JURISDICTION.
AutoCAD SHX Text
ACCORDANCE WITH ALL APPLICABLE STATUTES, CODES AND
AutoCAD SHX Text
B. CONFORM TO 2014 FLORIDA BUILDING CODE.
AutoCAD SHX Text
WILL BE DENIED BY THE ENGINEER.
AutoCAD SHX Text
THE OPENING OF BIDS, THEN HE SHALL BASE HIS BID ON
AutoCAD SHX Text
5. SUBSTITUTIONS REQUESTED ON THE BID PROPOSAL
AutoCAD SHX Text
ITEMS AND SYSTEMS AS SPECIFIED IN BID DOCUMENTS.
AutoCAD SHX Text
6. REQUESTS FOR ANY SUBSTITUTIONS NOT SUBMITTED
AutoCAD SHX Text
A. ALL INSTALLATIONS AND EQUIPMENT SHALL BE IN STRICT
AutoCAD SHX Text
C. CONFORM TO 2014 FLORIDA FIRE PREVENTION CODE.
AutoCAD SHX Text
BIDDER.
AutoCAD SHX Text
CUTS, PERFORMANCE AND TEST DATA OR INFORMATION
AutoCAD SHX Text
SUBSTITUTION, SUCH APPROVAL WILL BE ISSUED AS AN
AutoCAD SHX Text
ADDENDUM FORWARDED TO ALL PARTICIPATING BIDDERS.
AutoCAD SHX Text
ANY INTERPRETATION OR CORRECTION GIVEN BY ANY OTHER
AutoCAD SHX Text
REPRESENTS THAT HIS BID IS BASED UPON THE MATERIALS AND
AutoCAD SHX Text
EQUIPMENT WILL BE CONSIDERED UNLESS WRITTEN REQUEST HAS
AutoCAD SHX Text
BEEN SUBMITTED TO THE ENGINEER FOR APPROVAL AT LEAST
AutoCAD SHX Text
EACH SUCH REQUEST SHALL INCLUDE A COMPLETE DESCRIPTION
AutoCAD SHX Text
OF THE PROPOSED SUBSTITUTE, THE NAME OF THE MATERIAL OR
AutoCAD SHX Text
EQUIPMENT FOR WHICH IT IS TO BE SUBSTITUTED, DRAWINGS,
AutoCAD SHX Text
TEN (10) DAYS PRIOR TO THE DATE FOR RECEIPT OF BIDS.
AutoCAD SHX Text
NECESSARY FOR A COMPLETE EVALUATION.
AutoCAD SHX Text
1. EXCEPT AS PROVIDED BELOW, EACH BIDDER
AutoCAD SHX Text
2. NO SUBSTITUTIONS FOR OTHER MATERIALS AND
AutoCAD SHX Text
3. IF THE ENGINEER APPROVES ANY PROPOSED
AutoCAD SHX Text
EQUIPMENT DESCRIBED IN THE BIDDING DOCUMENTS.
AutoCAD SHX Text
4. IF ANY BIDDER IS UNABLE TO PROCURE WRITTEN
AutoCAD SHX Text
METHOD.
AutoCAD SHX Text
H. SUBSTITUTIONS
AutoCAD SHX Text
K. WHERE PIPE SUPPORT MEMBERS ARE WELDED TO STRUCTURAL
AutoCAD SHX Text
BUILDING FRAMING, SCRAPE, BRUSH CLEAN, AND APPLY ONE COAT
AutoCAD SHX Text
L. EXTEND CLEANOUTS TO FINISHED FLOOR OR WALL SURFACE.
AutoCAD SHX Text
LUBRICATE THREADED CLEANOUT PLUGS WITH MIXTURE OF GRAPHITE
AutoCAD SHX Text
AND LINSEED OIL. ENSURE CLEARANCE AT CLEANOUT FOR RODDING
AutoCAD SHX Text
OF ZINC RICH PRIMER TO WELDING.
AutoCAD SHX Text
OF DRAINAGE SYSTEM.
AutoCAD SHX Text
BE SHOWN. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR
AutoCAD SHX Text
SATISFACTION OF ALL TRADES, SUBJECT TO THE REVIEW AND FINAL
AutoCAD SHX Text
INTERPRETATION OR CORRECTION WILL BE ISSUED AS AN
AutoCAD SHX Text
ACCEPTANCE OF THE ARCHITECT/ENGINEER. IN THE EVENT THAT
AutoCAD SHX Text
THE CONTRACTOR INSTALLS HIS WORK BEFORE COORDINATING WITH
AutoCAD SHX Text
OTHER TRADES OR SO AS TO CAUSE ANY INTERFERENCE WITH THE
AutoCAD SHX Text
WORK OF THE OTHER TRADES THIS CONTRACTOR SHALL MAKE ALL
AutoCAD SHX Text
REQUIRED CHANGES TO CORRECT THE CONDITION AT NO ADDITIONAL
AutoCAD SHX Text
PRIOR TO INSTALLATION OF ANY SYSTEMS. THIS CONTRACTOR SHALL
AutoCAD SHX Text
ADJUST PIPING SYSTEM SIZES AS REQUIRED TO MATCH EQUIPMENT
AutoCAD SHX Text
CONNECTIONS. UTILIZE REDUCERS WHERE EQUIPMENT CONNECTIONS
AutoCAD SHX Text
CAREFULLY AND NOT LATER THAN TEN (10) DAYS PRIOR TO THE
AutoCAD SHX Text
DATE FOR RECEIPT OF BIDS, SHALL MAKE WRITTEN REQUEST TO
AutoCAD SHX Text
ARE SMALLER THAN PIPE SIZES INDICATED ON PLANS, NO PIPING
AutoCAD SHX Text
F. CONTRACTOR SHALL VERIFY ALL EQUIPMENT CONNECTION SIZES
AutoCAD SHX Text
THE ENGINEER FOR INTERPRETATION OR CORRECTION OF ANY
AutoCAD SHX Text
G. EXAMINATION OF BIDDING DOCUMENTS:
AutoCAD SHX Text
AMBIGUITY, INCONSISTENCY OR ERROR THEREIN. ANY
AutoCAD SHX Text
SHALL BE DECREASED IN SIZE (IN THE DIRECTION OF FLOW).
AutoCAD SHX Text
1. EACH BIDDER SHALL EXAMINE THE BIDDING DOCUMENTS
AutoCAD SHX Text
INTERPRETATION OR CORRECTION TO BID DOCUMENTS BY
AutoCAD SHX Text
ADDENDUM BY THE ENGINEER. ONLY A WRITTEN
AutoCAD SHX Text
COST TO THE PROJECT.
AutoCAD SHX Text
ADDITIONAL COST INCURRED.
AutoCAD SHX Text
BY CODE AND OTHER SECTIONS SHALL BE COORDINATED AND
AutoCAD SHX Text
MINUTE ITEMS REQUIRED SUCH AS COMPONENTS, PARTS, CONTROLS
AutoCAD SHX Text
AND DEVICES WHICH MAY BE REQUIRED TO PRODUCE THE EQUIPMENT
AutoCAD SHX Text
PERFORMANCE SPECIFIED OR AS REQUIRED TO MEET THE EQUIPMENT
AutoCAD SHX Text
WARRANTIES. WHERE SUCH ITEMS ARE REQUIRED, THEY SHALL BE
AutoCAD SHX Text
INCLUDED BY THE INSTALLER OF THE EQUIPMENT, WHETHER OR NOT
AutoCAD SHX Text
SPECIFICALLY INDICATED IN THE CONTRACT DOCUMENTS WITH NO
AutoCAD SHX Text
OTHERS, AND SHALL MAKE ALL FINAL CONNECTIONS. CONTRACTOR
AutoCAD SHX Text
SHALL INSTALL EQUIPMENT AND SYSTEMS IN STRICT ACCORDANCE
AutoCAD SHX Text
SECTIONS OF THE SPECIFICATION, THE CONTRACTOR FOR THIS
AutoCAD SHX Text
DIVISION SHALL INSTALL PLUMBING EQUIPMENT FURNISHED BY
AutoCAD SHX Text
FIRE AND/OR SMOKE DAMPERS, AND OTHER BASIC ITEMS REQUIRED
AutoCAD SHX Text
SELECTING THE EQUIPMENT TO FIT THE SPACE PROVIDED. THE
AutoCAD SHX Text
C. EQUIPMENT SPECIFICATIONS MAY NOT DEAL INDIVIDUALLY WITH
AutoCAD SHX Text
LOCATION AND SIZES FOR PIPE FITTINGS, SLEEVES, INSERTS,
AutoCAD SHX Text
INCLUDED FOR THE PROPER INSTALLATION OF THE WORK.
AutoCAD SHX Text
WITH MANUFACTURERS RECOMMENDATIONS.
AutoCAD SHX Text
D. WHERE NOTED ON THE DRAWINGS OR INDICATED IN OTHER
AutoCAD SHX Text
DRAWINGS. TIGHT SPACE CONDITIONS SHALL BE DETAILED TO THE
AutoCAD SHX Text
E. COORDINATE WITH ALL TRADES IN SUBMITTAL OF SHOP
AutoCAD SHX Text
FABRICATION, START-UP AND TESTS FOR A COMPLETE OPERATIONAL
AutoCAD SHX Text
EQUIPMENT AND MATERIALS SPECIFIED IN THIS DIVISION AND AS
AutoCAD SHX Text
CALLED FOR ON THE DRAWINGS. WORK SHALL ALSO INCLUDE
AutoCAD SHX Text
SUPERVISION, OPERATION, METHODS AND LABOR FOR THE
AutoCAD SHX Text
ARE INTENDED TO CONVEY THE SCOPE OF THE INSTALLATION AND TO
AutoCAD SHX Text
INDICATE THE GENERAL ARRANGEMENT AND LOCATIONS OF THE WORK.
AutoCAD SHX Text
B. DRAWINGS FOR THE WORK ARE DIAGRAMMATIC IN NATURE AND
AutoCAD SHX Text
15 SECTIONS, IN ADDITION TO DIVISION 1 - GENERAL
AutoCAD SHX Text
A. GENERAL PROVISIONS SPECIFICALLY APPLICABLE TO DIVISION
AutoCAD SHX Text
A. THE WORK SHALL INCLUDE THE PROVISIONS OF SYSTEMS,
AutoCAD SHX Text
SUCH AS PIPE FITTINGS, ACCESS PANELS, AND SLEEVES MAY NOT
AutoCAD SHX Text
BECAUSE OF THE SCALE OF THE DRAWINGS, CERTAIN BASIC ITEMS
AutoCAD SHX Text
PLUMBING INSTALLATION.
AutoCAD SHX Text
REQUIREMENTS.
AutoCAD SHX Text
1.1 SECTION INCLUDES
AutoCAD SHX Text
PART 1 GENERAL
AutoCAD SHX Text
1.2 SCOPE
AutoCAD SHX Text
BUILDING TO ENSURE PROPER SLOPE AND COVER.
AutoCAD SHX Text
H. PROVIDE ACCESS WHERE VALVES AND FITTINGS ARE NOT
AutoCAD SHX Text
EXPOSED. COORDINATE SIZE AND LOCATION OF ACCESS DOORS WITH
AutoCAD SHX Text
I. ESTABLISH ELEVATIONS OF BURIED PIPING OUTSIDE THE
AutoCAD SHX Text
B. PROVIDE NON-CONDUCTING DIELECTRIC CONNECTIONS WHEREVER
AutoCAD SHX Text
C. ROUTE PIPING IN ORDERLY MANNER AND MAINTAIN GRADIENT.
AutoCAD SHX Text
F. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION
AutoCAD SHX Text
WITHOUT STRESSING PIPE, JOINTS, OR CONNECTED EQUIPMENT.
AutoCAD SHX Text
G. PROVIDE CLEARANCE FOR INSTALLATION OF INSULATION AND
AutoCAD SHX Text
D. INSTALL PIPING TO CONSERVE BUILDING SPACE AND NOT
AutoCAD SHX Text
E. GROUP PIPING WHENEVER PRACTICAL AT COMMON ELEVATIONS.
AutoCAD SHX Text
J. ESTABLISH ELEVATIONS OF EXISTING BURIED PIPING FOR
AutoCAD SHX Text
APPROPRIATE ARCHITECTURAL SECTION.
AutoCAD SHX Text
ACCESS TO VALVES AND FITTINGS.
AutoCAD SHX Text
JOINTING DISSIMILAR METALS.
AutoCAD SHX Text
INTERFERE WITH USE OF SPACE.
AutoCAD SHX Text
A. CAST IRON: CISPI 301, SERVICE WEIGHT, NO HUB.
AutoCAD SHX Text
2. JOINTS: CISPI 301 STAINLESS STEEL CLAMPS, MINIMUM 24 GA. WITH
AutoCAD SHX Text
A. COPPER PIPING: ASTM B88 TYPE 'L' HARD DRAWN.
AutoCAD SHX Text
2. JOINTS: ASTM B32 SOLDER, ASTM 95-5 TA MINIMUM, FLUX ASTM B813.
AutoCAD SHX Text
2.3 PIPING: SANITARY SEWER PIPING, ABOVE GRADE
AutoCAD SHX Text
1. FITTINGS: ASME 16.18 CAST BRONZE OR ASME B16.22 WROUGHT
AutoCAD SHX Text
A. INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S
AutoCAD SHX Text
INSTRUCTIONS.
AutoCAD SHX Text
COPPER OR BRONZE.
AutoCAD SHX Text
PART 3 INSTALLATION
AutoCAD SHX Text
1. FITTINGS: CISPI 301 CAST IRON DWV.
AutoCAD SHX Text
2.5 PIPING: WATER PIPING, ABOVE GRADE
AutoCAD SHX Text
ASTM C547, RIGID MOLDED NON-COMBUSTIBLE FIBERGLASS INSULATION.
AutoCAD SHX Text
VAPOR BARRIER JACKET, KRAFT PAPER WITH GLASS FIBER YARN AND BONDED
AutoCAD SHX Text
2. OTHER ACCEPTABLE MANUFACTURERS OFFERING
AutoCAD SHX Text
2.2 HOT WATER WATER PIPING INSULATION
AutoCAD SHX Text
TO ALUMINUM FILM. CLOSURE SYSTEM SHALL BE UL 181.
AutoCAD SHX Text
'K' VALUE .024 @ 75 DEGREES F.
AutoCAD SHX Text
INSULATION THICKNESS 1-1/2"
AutoCAD SHX Text
B.
AutoCAD SHX Text
C.
AutoCAD SHX Text
D.
AutoCAD SHX Text
1. OWENS-CORNING
AutoCAD SHX Text
MANUFACTURERS:
AutoCAD SHX Text
3. KNAUF
AutoCAD SHX Text
2. JOHNS-MANVILLE
AutoCAD SHX Text
A.
AutoCAD SHX Text
EQUIVALENT PRODUCTS.
AutoCAD SHX Text
A) MICHIGAN HANGER.
AutoCAD SHX Text
B) PHD.
AutoCAD SHX Text
1. B-LINE.
AutoCAD SHX Text
M. RESET SPRINKLER HEADS FROM UPRIGHT POSITION TO DOWN
AutoCAD SHX Text
POSITION TO CENTER OF NEW CEILING TILE.
AutoCAD SHX Text
NEOPRENE GASKET. HUSKEY SERIES 4000 OR CLAMP-ALL ONLY.
AutoCAD SHX Text
JOINTS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM B828.
AutoCAD SHX Text
%%u
AutoCAD SHX Text
INTEGRITY OF WEATHER.
AutoCAD SHX Text
CUTTING AND PATCHING
AutoCAD SHX Text
WORK OF OWNER OR SEPERATE CONTRACTOR.
AutoCAD SHX Text
EFFICIENCY, MAINTENANCE, OR SAFETY OF ELEMENT.
AutoCAD SHX Text
VISUAL QUALITIES OF SIGHT.
AutoCAD SHX Text
STRUCTURAL INTEGRITY OF ELEMENT.
AutoCAD SHX Text
5
AutoCAD SHX Text
.
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
4
AutoCAD SHX Text
1.
AutoCAD SHX Text
2
AutoCAD SHX Text
.
AutoCAD SHX Text
1
AutoCAD SHX Text
.
AutoCAD SHX Text
.
AutoCAD SHX Text
4
AutoCAD SHX Text
.
AutoCAD SHX Text
3
AutoCAD SHX Text
.
AutoCAD SHX Text
.
AutoCAD SHX Text
SUBMIT WRITTEN REQUEST IN ADVANCE OF CUTTING OR ALTERING
AutoCAD SHX Text
EMPLOY SKILLED AND EXPERIENCED INSTALLER TO PERFORM
AutoCAD SHX Text
CUTTING AND PATCHING WHICH EFFECT:
AutoCAD SHX Text
A. PVC: ASTM D2665 SCHEDULE 40 PVC PIPING.
AutoCAD SHX Text
2. JOINTS: ASTM D2564 SOLVENT CEMENT. JOINTS SHALL BE
AutoCAD SHX Text
2.4 PIPING: SANITARY SEWER PIPING, ABOVE AND BELOW GRADE
AutoCAD SHX Text
1. FITTINGS: ASTM D2665 SCHEDULE 40 PVC DWV FITTINGS.
AutoCAD SHX Text
INSTALLED IN ACCORDANCE WITH ASTM D2855.
AutoCAD SHX Text
K. TORQUE ALL HUBLESS CAST IRON COUPLING IN STRICT ACCORDANCE
AutoCAD SHX Text
WITH THE MANUFACTURERS RECOMMENDATIONS. UTILIZE COUPLING
AutoCAD SHX Text
MANUFACTURERS PRE-SET TORQUE WRENCH.
AutoCAD SHX Text
ELEMENTS.
AutoCAD SHX Text
SPECIFICATION
AutoCAD SHX Text
TO EXISTING
AutoCAD SHX Text
T
AutoCAD SHX Text
A
AutoCAD SHX Text
HOSE BIBB
AutoCAD SHX Text
SECTION DESIGNATION
AutoCAD SHX Text
POINT OF REMOVAL FOR DEMOLITION
AutoCAD SHX Text
POINT OF CONNECTION NEW
AutoCAD SHX Text
DELTA T (TEMPERATURE DIFFERENCE)
AutoCAD SHX Text
SHEET WHERE SECTION CUT
AutoCAD SHX Text
SHEET WHERE SECTION APPEARS
AutoCAD SHX Text
G
AutoCAD SHX Text
HUB DRAIN
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
TRENCH DRAIN
AutoCAD SHX Text
G
AutoCAD SHX Text
A
AutoCAD SHX Text
HOR
AutoCAD SHX Text
A
AutoCAD SHX Text
GAS LINE (ABOVE GRADE)
AutoCAD SHX Text
GAS LINE (BELOW GRADE)
AutoCAD SHX Text
HEATING OIL RETURN (BELOW GRADE)
AutoCAD SHX Text
COMPRESSED AIR (ABOVE GRADE)
AutoCAD SHX Text
COMPRESSED AIR (BELOW GRADE)
AutoCAD SHX Text
HOR
AutoCAD SHX Text
HOS
AutoCAD SHX Text
HOS
AutoCAD SHX Text
SAN
AutoCAD SHX Text
SAN
AutoCAD SHX Text
CLEANOUT
AutoCAD SHX Text
FLOOR CLEANOUT
AutoCAD SHX Text
HORIZONTAL CLEANOUT
AutoCAD SHX Text
SANITARY SEWER (BELOW GRADE)
AutoCAD SHX Text
HEATING OIL SUPPLY (ABOVE GRADE)
AutoCAD SHX Text
HEATING OIL SUPPLY (BELOW GRADE)
AutoCAD SHX Text
HEATING OIL RETURN (ABOVE GRADE)
AutoCAD SHX Text
SANITARY SEWER (ABOVE GRADE)
AutoCAD SHX Text
PIPE SECTION-SUPPLY
AutoCAD SHX Text
PIPE SECTION-RETURN
AutoCAD SHX Text
A
AutoCAD SHX Text
PIPE UP
AutoCAD SHX Text
PIPE DOWN
AutoCAD SHX Text
PITCH PIPE DOWN IN DIRECTION OF ARROW
AutoCAD SHX Text
DIRECTION OF FLOW IN PIPE
AutoCAD SHX Text
G
AutoCAD SHX Text
EJ
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
PIPE GUIDE
AutoCAD SHX Text
BC
AutoCAD SHX Text
GATE VALVE
AutoCAD SHX Text
BALANCING COCK
AutoCAD SHX Text
GLOBE VALVE
AutoCAD SHX Text
RV
AutoCAD SHX Text
PRV
AutoCAD SHX Text
MAV
AutoCAD SHX Text
MANUAL AIR VENT
AutoCAD SHX Text
S
AutoCAD SHX Text
CAPPED LINE
AutoCAD SHX Text
SOLENOID VALVE
AutoCAD SHX Text
VALVE OS & Y
AutoCAD SHX Text
DOMESTIC COLD WATER
AutoCAD SHX Text
CHECK VALVE, HORIZONTAL SWING
AutoCAD SHX Text
FLEXIBLE PIPE CONNECTOR
AutoCAD SHX Text
STRAINER, Y-TYPE AND BLOWOFF VALVE
AutoCAD SHX Text
PRESSURE RELIEF VALVE (WATER)
AutoCAD SHX Text
PRESSURE REDUCING VALVE
AutoCAD SHX Text
PIPE ANCHOR
AutoCAD SHX Text
M-I M-2
AutoCAD SHX Text
PLUMBING LEGEND
AutoCAD SHX Text
FD
AutoCAD SHX Text
HB
AutoCAD SHX Text
HD
AutoCAD SHX Text
TD
AutoCAD SHX Text
ITEMS TO BE REMOVED (DEMOLITION)
AutoCAD SHX Text
CWF
AutoCAD SHX Text
COLD FILTERED WATER
AutoCAD SHX Text
COLD NANO WATER
AutoCAD SHX Text
SHOCK ABSORBER
AutoCAD SHX Text
CWN
AutoCAD SHX Text
CD
AutoCAD SHX Text
CD
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
EO
AutoCAD SHX Text
GR
AutoCAD SHX Text
GR
AutoCAD SHX Text
AW
AutoCAD SHX Text
AV
AutoCAD SHX Text
ACID VENT
AutoCAD SHX Text
SOFT COLD WATER
AutoCAD SHX Text
VENT
AutoCAD SHX Text
SCW
AutoCAD SHX Text
AW
AutoCAD SHX Text
CONDENSATE DRAIN (BELOW GRADE)
AutoCAD SHX Text
DOMESTIC HOT WATER RETURN
AutoCAD SHX Text
STORM SEWER (BELOW GRADE)
AutoCAD SHX Text
GREASE SEWER (ABOVE GRADE)
AutoCAD SHX Text
GREASE SEWER (BELOW GRADE)
AutoCAD SHX Text
ACID WASTE (ABOVE GRADE)
AutoCAD SHX Text
ACID WASTE (BELOW GRADE)
AutoCAD SHX Text
STORM SEWER (ABOVE GRADE)
AutoCAD SHX Text
CONDENSATE DRAIN (ABOVE GRADE)
AutoCAD SHX Text
STORM EMERGENCY OVERFLOW PIPING
AutoCAD SHX Text
DOMESTIC HOT WATER
AutoCAD SHX Text
OUTSIDE DIAMETER
AutoCAD SHX Text
PRESSURE
AutoCAD SHX Text
PSI GAUGE
AutoCAD SHX Text
PRESSURE
AutoCAD SHX Text
PRESSURE DROP
AutoCAD SHX Text
PLUMBING CONTRACTOR
AutoCAD SHX Text
PSI ABSOLUTE
AutoCAD SHX Text
POUNDS PER SQUARE INCH
AutoCAD SHX Text
OUTLET VELOCITY
AutoCAD SHX Text
OD
AutoCAD SHX Text
P
AutoCAD SHX Text
PD
AutoCAD SHX Text
PC
AutoCAD SHX Text
PSI
AutoCAD SHX Text
PSIA
AutoCAD SHX Text
PSIG
AutoCAD SHX Text
PRESS
AutoCAD SHX Text
OV
AutoCAD SHX Text
FC
AutoCAD SHX Text
FCO
AutoCAD SHX Text
FD
AutoCAD SHX Text
FG
AutoCAD SHX Text
FLA
AutoCAD SHX Text
FIN FL
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
FLEXIBLE CONNECTION
AutoCAD SHX Text
FLOOR CLEANOUT
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text
FULL LOAD AMPERES
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
FINISHED FLOOR
AutoCAD SHX Text
RISE
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
POLYVINYL CHLORIDE
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
RELIEF VALVE
AutoCAD SHX Text
REVOLUTIONS PER MINUTE
AutoCAD SHX Text
PVC
AutoCAD SHX Text
R
AutoCAD SHX Text
REQ'D
AutoCAD SHX Text
RPM
AutoCAD SHX Text
RM
AutoCAD SHX Text
RV
AutoCAD SHX Text
SANITARY
AutoCAD SHX Text
STORM MANHOLE
AutoCAD SHX Text
SPECIFICATION
AutoCAD SHX Text
STORM
AutoCAD SHX Text
TOTAL DYNAMIC HEAD
AutoCAD SHX Text
TRENCH DRAIN
AutoCAD SHX Text
TEMPERATURE
AutoCAD SHX Text
SOFT COLD WATER
AutoCAD SHX Text
SAN
AutoCAD SHX Text
SMH
AutoCAD SHX Text
SPEC
AutoCAD SHX Text
TD
AutoCAD SHX Text
SCW
AutoCAD SHX Text
ST
AutoCAD SHX Text
TEMP
AutoCAD SHX Text
TDH
AutoCAD SHX Text
GAUGE
AutoCAD SHX Text
FOB
AutoCAD SHX Text
FPM
AutoCAD SHX Text
FPS
AutoCAD SHX Text
GA
AutoCAD SHX Text
FOT
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text
WATER
AutoCAD SHX Text
GO
AutoCAD SHX Text
H
AutoCAD SHX Text
HB
AutoCAD SHX Text
H20
AutoCAD SHX Text
GAL
AutoCAD SHX Text
GPM
AutoCAD SHX Text
GPH
AutoCAD SHX Text
GALLONS PER HOUR
AutoCAD SHX Text
GALLONS PER MINUTE
AutoCAD SHX Text
FEET PER SECOND
AutoCAD SHX Text
FEET PER MINUTE
AutoCAD SHX Text
FLAT ON BOTTOM
AutoCAD SHX Text
GALLONS
AutoCAD SHX Text
GAS OUTLET
AutoCAD SHX Text
HOSE BIBB
AutoCAD SHX Text
FLAT ON TOP
AutoCAD SHX Text
HEAD
AutoCAD SHX Text
HOUR
AutoCAD SHX Text
HD
AutoCAD SHX Text
HP
AutoCAD SHX Text
HR
AutoCAD SHX Text
HORIZ
AutoCAD SHX Text
HW
AutoCAD SHX Text
HZ
AutoCAD SHX Text
ID
AutoCAD SHX Text
IN
AutoCAD SHX Text
IPS
AutoCAD SHX Text
INSUL
AutoCAD SHX Text
KW
AutoCAD SHX Text
INV
AutoCAD SHX Text
INCH OR INCHES
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
IRON PIPE SIZE
AutoCAD SHX Text
KILOWATT
AutoCAD SHX Text
HORIZONTAL
AutoCAD SHX Text
HORSEPOWER
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
FREQUENCY
AutoCAD SHX Text
INSIDE DIAMETER
AutoCAD SHX Text
INVERT ELEVATION
AutoCAD SHX Text
AMPERES
AutoCAD SHX Text
ACCESS PANEL
AutoCAD SHX Text
ACCESS DOOR
AutoCAD SHX Text
AUXILIARY
AutoCAD SHX Text
AUTOMATIC
AutoCAD SHX Text
ARCHITECTURAL
AutoCAD SHX Text
APPROXIMATELY
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
AUTOMATIC CONTROL SYSTEM
AutoCAD SHX Text
A
AutoCAD SHX Text
ACS
AutoCAD SHX Text
AD
AutoCAD SHX Text
AFF
AutoCAD SHX Text
AP
AutoCAD SHX Text
ARCH
AutoCAD SHX Text
AUX
AutoCAD SHX Text
AUTO
AutoCAD SHX Text
APPROX
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
CONDENSATE DRAIN
AutoCAD SHX Text
BACK WATER VALVE
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
COMBINATION
AutoCAD SHX Text
CLEAN-OUT
AutoCAD SHX Text
BRITISH THERMAL UNIT
AutoCAD SHX Text
BRITISH THERMAL UNITS PER HOUR
AutoCAD SHX Text
CENTRAL CONTROL PANEL
AutoCAD SHX Text
COMPRESSOR
AutoCAD SHX Text
CUBIC FEET
AutoCAD SHX Text
CONTINUATION
AutoCAD SHX Text
CUBIC INCHES
AutoCAD SHX Text
COLD WATER (CITY)
AutoCAD SHX Text
DRAIN LINE
AutoCAD SHX Text
CONCRETE MASONRY UNIT
AutoCAD SHX Text
CONDENSATE OR CONDENSER
AutoCAD SHX Text
BTU
AutoCAD SHX Text
BWV
AutoCAD SHX Text
CD
AutoCAD SHX Text
CCP
AutoCAD SHX Text
CLG
AutoCAD SHX Text
CO
AutoCAD SHX Text
CMU
AutoCAD SHX Text
CW
AutoCAD SHX Text
D
AutoCAD SHX Text
COMB
AutoCAD SHX Text
CONT
AutoCAD SHX Text
COND
AutoCAD SHX Text
COMPR
AutoCAD SHX Text
CU FT
AutoCAD SHX Text
CU IN
AutoCAD SHX Text
BLDG
AutoCAD SHX Text
BTUH
AutoCAD SHX Text
BRAKE HORSEPOWER
AutoCAD SHX Text
BHP
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
VENT LINE
AutoCAD SHX Text
VALVE
AutoCAD SHX Text
VENT THRU ROOF
AutoCAD SHX Text
WITH
AutoCAD SHX Text
WITHOUT
AutoCAD SHX Text
WIDTH
AutoCAD SHX Text
WALL CLEANOUT
AutoCAD SHX Text
WORKING PRESSURE
AutoCAD SHX Text
WATER GAUGE
AutoCAD SHX Text
WATER COLUMN
AutoCAD SHX Text
TYP
AutoCAD SHX Text
V
AutoCAD SHX Text
VLV
AutoCAD SHX Text
VTR
AutoCAD SHX Text
W/
AutoCAD SHX Text
W/O
AutoCAD SHX Text
W
AutoCAD SHX Text
WCO
AutoCAD SHX Text
WC
AutoCAD SHX Text
WG
AutoCAD SHX Text
WP
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
RD
AutoCAD SHX Text
LBS
AutoCAD SHX Text
LIN FT
AutoCAD SHX Text
MAX
AutoCAD SHX Text
MIN
AutoCAD SHX Text
MC
AutoCAD SHX Text
LB/HR POUNDS PER HOUR
AutoCAD SHX Text
MECHANICAL CONTRACTOR
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
POUNDS
AutoCAD SHX Text
LINEAR FEET
AutoCAD SHX Text
NO.
AutoCAD SHX Text
NTS NOT TO SCALE
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
NO NORMALLY OPEN
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
EQUAL
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
EXPANSION
AutoCAD SHX Text
ELECTRIC
AutoCAD SHX Text
EMERGENCY OVERFLOW PIPING
AutoCAD SHX Text
EMERGENCY SHOWER/EYEWASH
AutoCAD SHX Text
DEGREES FAHRENHEIT
AutoCAD SHX Text
EL
AutoCAD SHX Text
EQ
AutoCAD SHX Text
EO
AutoCAD SHX Text
EXP
AutoCAD SHX Text
ESEW
AutoCAD SHX Text
%%DF
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
EXST
AutoCAD SHX Text
L
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
EXTERIOR CLEANOUT
AutoCAD SHX Text
ECO
AutoCAD SHX Text
BUTTERFLY VALVE
AutoCAD SHX Text
BOOSTED PRESSURE DOMESTIC COLD WATER
AutoCAD SHX Text
BP
AutoCAD SHX Text
EXTERIOR CLEANOUT
AutoCAD SHX Text
BALANCING VALVE
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
MBH
AutoCAD SHX Text
THOUSANDS, BTUH
AutoCAD SHX Text
NC
AutoCAD SHX Text
NORMALLY CLOSED
AutoCAD SHX Text
1.
AutoCAD SHX Text
2.
AutoCAD SHX Text
3.
AutoCAD SHX Text
4.
AutoCAD SHX Text
5.
AutoCAD SHX Text
6.
AutoCAD SHX Text
7.
AutoCAD SHX Text
8.
AutoCAD SHX Text
9.
AutoCAD SHX Text
10.
AutoCAD SHX Text
11.
AutoCAD SHX Text
12.
AutoCAD SHX Text
13.
AutoCAD SHX Text
14.
AutoCAD SHX Text
15.
AutoCAD SHX Text
16.
AutoCAD SHX Text
17.
AutoCAD SHX Text
18.
AutoCAD SHX Text
19.
AutoCAD SHX Text
20.
AutoCAD SHX Text
21.
AutoCAD SHX Text
22.
AutoCAD SHX Text
23.
AutoCAD SHX Text
24.
AutoCAD SHX Text
25.
AutoCAD SHX Text
ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES,
AutoCAD SHX Text
RULES AND ORDINANCES.
AutoCAD SHX Text
THE CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING
AutoCAD SHX Text
CONDITIONS.
AutoCAD SHX Text
ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR, IN A FIRST-CLASS AND
AutoCAD SHX Text
WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE.
AutoCAD SHX Text
ALL EXCAVATION AND BACKFILL, AS REQUIRED, FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF
AutoCAD SHX Text
THIS CONTRACT.
AutoCAD SHX Text
PROOF OF INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR FOR PROTECTION AGAINST PUBLIC
AutoCAD SHX Text
LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK.
AutoCAD SHX Text
VERIFY LOCATION, SIZE, INVERTS AND ALL EXISTING UTILITIES PRIOR TO BEGINNING OF CONSTRUCTION.
AutoCAD SHX Text
ADVISE ENGINEER OF ANY DISCREPANCIES.
AutoCAD SHX Text
WATER PIPING SHALL BE TYPE "L" COPPER FOR 2 1/2" ABOVE GRADE. ALL UNDERGROUND WATER PIPING
AutoCAD SHX Text
SHALL BE TYPE "K" COPPER WITH NO JOINTS UNDER SLAB.
AutoCAD SHX Text
SOIL, WASTE, VENT AND RAINWATER PIPING SHALL BE CAST IRON NO. HUB 301-72 ABOVE GRADE.
AutoCAD SHX Text
MECHANICAL JOINTS WITH S.S. CLAMPS BELOW GRADE. (USE SCHEDULE 40 PVC. WHERE ACCEPTABLE BY CODE,
AutoCAD SHX Text
AT THE CONTRACTORS OPTION.)
AutoCAD SHX Text
AIR CONDITIONING CONDENSATE DRAIN PIPING SHALL BE COPPER DWV PIPE AND FITTINGS. INSULATE ALL
AutoCAD SHX Text
CONDENSATE PIPING ABOVE GRADE.
AutoCAD SHX Text
INSULATE ALL HOT WATER SUPPLY, HOT WATER RETURN, RAINWATER AND CONDENSATE LINES ABOVE
AutoCAD SHX Text
GRADE AS FOLLOWS: (ONLY WHERE REQUIRED BY CODE.)
AutoCAD SHX Text
HOT WATER SUPPLY AND RETURN, 1 1/2" THICK FIBERGLASS.
AutoCAD SHX Text
RAINWATER LEADERS 1 ½" THICK FIBERGLASS BLANKET ON DRAIN BODY AND 1” HORIZONTAL AWL
AutoCAD SHX Text
ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS AND MARKED ACCESS PANELS.
AutoCAD SHX Text
FURNISH AND INSTALL APPROVED AIR CHAMBERS AT EACH PLUMBING FIXTURE GROUP AND P.D. I.
AutoCAD SHX Text
APPROVED SHOCK ARRESTERS ON MAIN LINES OR RISER.
AutoCAD SHX Text
DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL PIPING AND EQUIPMENT
AutoCAD SHX Text
CONNECTIONS.
AutoCAD SHX Text
ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD (HAIR FELT LINING) SUPER
AutoCAD SHX Text
STRUT MODEL C/15/16. FILL VOIDS BETWEEN PIPE AND WALL/FLOOR SLEEVES WITH FIRE-RATED FOAM SIMILAR
AutoCAD SHX Text
TO CHASE TECHNOLOGY CORP. – CIC PR-855
AutoCAD SHX Text
CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A
AutoCAD SHX Text
PERIOD OF ONE (1) YEAR FROM DATE OF C.O. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT
AutoCAD SHX Text
ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE
AutoCAD SHX Text
INSTALLATION WHICH MAY HAVE BEEN DAMAGED.
AutoCAD SHX Text
PROVIDE 1/4" TRAP PRIMER LINE FOR ALL FLOOR DRAINS FROM THE NEAREST PLUMBING FIXTURE.
AutoCAD SHX Text
PROVIDE MINIMUM 3' RADIUS, 1/4" PER FOOT SLOPE AROUND ALL FLOOR DRAINS.
AutoCAD SHX Text
PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES AND ALL WATER HAMMER ARRESTORS. ACCESS
AutoCAD SHX Text
PANELS IN RATED WALLS MUST MAINTAIN THE RATING. ALL ACCESS PANELS MUST MATCH THE FINISH OF THE
AutoCAD SHX Text
WALL IN WHICH IT IS INSTALLED.
AutoCAD SHX Text
PROVIDE CHROME-PLATED COMBINATION COVER PLATE AND CLEANOUT PLUG FOR ALL WALL CLEANOUTS
AutoCAD SHX Text
ZURN - ZN-1446 OR EQUAL.
AutoCAD SHX Text
PROVIDE EACH FIXTURE GROUP WITH ISOLATION VALVES, BOTH HOT (110) AND COLD WATER.
AutoCAD SHX Text
NO COMBUSTIBLE MATERIALS CAN BE USED IN MECHANICAL ROOMS OR IN CEILING SPACES WHERE USED
AutoCAD SHX Text
AS RETURN AIR PLENUMS.
AutoCAD SHX Text
PROVIDE BACKFLOW PREVENTER - WILKINS MOD. # 575 OR EQUAL.
AutoCAD SHX Text
THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND INDICATE THE APPROXIMATE ROUTING OF PIPING
AutoCAD SHX Text
AND LOCATION OF FIXTURES. THE CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADES AND MAKE
AutoCAD SHX Text
MINOR OFFSETS AND ADJUSTMENTS AS REQUIRED AT NO ADDITIONAL COST TO THE OWNER
AutoCAD SHX Text
COORDINATE FIXTURES LOCATIONS WITH ARCHITECTURAL DRAWINGS.
AutoCAD SHX Text
CONTRACTOR SHALL MAKE ARRANGEMENTS FOR CONNECTIONS TO ALL UTILITY LINES AND PAY ALL FEES
AutoCAD SHX Text
AND COSTS FOR CONNECTIONS TO THOSE SERVICES
AutoCAD SHX Text
ALL PIPING SHALL BE RUN IN CONCEALED LOCATIONS EXCEPT WHERE NOTED.
AutoCAD SHX Text
26.
AutoCAD SHX Text
27.
AutoCAD SHX Text
28.
AutoCAD SHX Text
29.
AutoCAD SHX Text
30.
AutoCAD SHX Text
31.
AutoCAD SHX Text
32.
AutoCAD SHX Text
33.
AutoCAD SHX Text
34.
AutoCAD SHX Text
35.
AutoCAD SHX Text
36.
AutoCAD SHX Text
37.
AutoCAD SHX Text
38.
AutoCAD SHX Text
39.
AutoCAD SHX Text
40.
AutoCAD SHX Text
41.
AutoCAD SHX Text
42.
AutoCAD SHX Text
PLUMBING FIXTURES SHALL BE FIRST QUALITY VITREOUS CHINA, STAINLESS STEEL OR PLASTIC AS NOTED
AutoCAD SHX Text
ON FIXTURE SCHEDULE. ALL FIXTURES SHALL BE RIGIDLY CONNECTED TO THE BUILDING AND SHALL BE
AutoCAD SHX Text
CLEANED AND FUNCTIONAL PRIOR TO ACCEPTANCE.
AutoCAD SHX Text
REFER TO ARCHITECTURAL DRAWINGS FOR FINISHED GRADES.
AutoCAD SHX Text
CONTRACTOR SHALL PROVIDE PRESSURE REDUCING VALVE AND REDUCED PRESSURE BACKFLOW
AutoCAD SHX Text
PREVENTION VALVE INSIDE BUILDING WHERE SERVICE ENTERS OR AS SHOWN ON THE SITE PLAN.
AutoCAD SHX Text
EXPOSED PIPING BELOW FIXTURES SHALL BE CHROME PLATED. PIPING AT FIXTURES IN HANDICAPPED
AutoCAD SHX Text
ACCESSIBLE AREAS SHALL BE INSULATED TO PROTECT AGAINST BURNS.
AutoCAD SHX Text
ALL BURIED PIPING SHALL BE BEDDED AND COVERED IN SAND, GRAVEL, OR CRUSHED STONE.
AutoCAD SHX Text
AFTER COMPLETION OF PIPING TEST POTABLE WATER PIPING TO 125 LBS. PER SQ. INCH AND HOLD FOR 24
AutoCAD SHX Text
HOURS.
AutoCAD SHX Text
TEST DRAIN WASTE AND VENT PIPING BY FILLING TO LEVEL OF THE HIGHEST VENT.
AutoCAD SHX Text
AFTER INSTALLATION AND TESTING OF POTABLE WATER PIPING, STERILIZE ALL LINES IN ACCORD WITH
AutoCAD SHX Text
CODES AND HEALTH DEPARTMENT REGULATIONS AND FLUSH AND FILL WITH CLEAN WATER.
AutoCAD SHX Text
PITCH POTABLE WATER LINES TOWARD DRAINS, INSTALL DRAIN WASTE AND VENT PIPING WITH MINIMUM
AutoCAD SHX Text
SLOPES OF 1/4" PER FOOT FOR LINES UP TO 2 1/2" AND 1/8" PER FOOT FOR LINES 3" AND LARGER.
AutoCAD SHX Text
PROVIDE A TWO PIP DIAMETER AIR GAP BETWEEN ALL INDIRECT WASTE AND THE RECEIVER.
AutoCAD SHX Text
REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS AND RATING OF FIRE WALLS AND FLOOR CEILING
AutoCAD SHX Text
ASSEMBLIES.
AutoCAD SHX Text
INSTALL FIRE STOP MATERIAL IN ACCORD WITH U.L. LISTING AT ALL PENETRATIONS.
AutoCAD SHX Text
PIP WATER HEATER RELIEF VALVE TO EXTERIOR PER CODE OR TO FLOOR DRAIN.
AutoCAD SHX Text
PROVIDE MAXITROL SERIES GF OR EQUAL FUEL GAS STRAINER PER NFPA 86 UPSTREAM OF SAFETY
AutoCAD SHX Text
SHUTOFF VALVES. (PHONE NUMBER: (248) 356-1400).
AutoCAD SHX Text
INSTALL WATER HEATERS IN ACCORDANCE WITH MANUFACTURERS INSTRUCTION AND ALL STATE AND LOCAL
AutoCAD SHX Text
CODE REQUIREMENTS. WATER STORAGE SHALL HAVE A TEMPERATURE OF 140 DEGREES.
AutoCAD SHX Text
ALL LAVATORIES AND HAND SINKS SHALL HAVE AN APPROVED ASSE 1016 OR ASSE 1017 DEVICE(S) FOR
AutoCAD SHX Text
APPROVAL. COMPLY WITH ALL CODES.
AutoCAD SHX Text
ALL FOOD RELATED EQUIPMENT WITH DRAIN LINES, E.G., FOOD PREPARATION SINKS, WAREWASH SINKS,
AutoCAD SHX Text
ETC. WASTE THROUGH A TWO PIPE DEMETER AIR GAP OR APPROVED AIR BREAK. WATER HEATER/BOILER
AutoCAD SHX Text
POP-OFF LINE: ICE MACHINE AND ICE BIN MELTWATER DRAIN LINES, WATER FILTER/ TREATMENT EQUIPMENT
AutoCAD SHX Text
DRAIN LINES, AND SIMILAR DRAINS FROM EQUIPMENT USING DOMESTIC WATER (INCLUDING DIPPER WELLS)
AutoCAD SHX Text
MUST HAVE A TWO PIPE DIAMETER AIR GAP AT THE SEWER. EQUIPMENT SUCH AS DIPPER WELLS, STREAMERS,
AutoCAD SHX Text
WOK TABLE FLUSH SYSTEMS, AND SIMILAR DEVICES WITH THE POTENTIAL FOR SUBMERGED INLETS, ETC. MUST
AutoCAD SHX Text
HAVE AN APPROVED TOW PIPE DIAMETER AIR GAP OR DUAL CHECK VALVE MEETING ASSE STANDARD 1012, 1024,
AutoCAD SHX Text
OR EQUIVALENT INSTALLED ON THE POTABLE WATER SUPPLY.
Renee Engels
KEATOR CONSTRUCTION - BID SET