To Be Signed As Agreed Multi Party Punch
NSH Jacobs SADARA ACA
Name: BASALAN KESAVAMOORTHI.R
Signature:
Position: EQUIP.INSPECTOR EQUIP.INSPECTOR
Date: 02-Feb-2016 02-Feb-2016
NSH Document Reference: NSH-SCB-G-FM-038 Revision 0
Chemicals 1 Project (Chlorine & Brine)
Contract No 10027 & 10028
PUNCH LIST
Turnover System No: 210M-3800-PR-00
Sub System No: 210M-3848-PR-00
Test Pack No: 28-P-3855 A&B
Discipline Code: C=Civil, K= Electrical, T=Design As Built, M=Equipment,J=Instrument,P=Piping,H=Communication, B= Building, I=Insulation,
S=Structure, V=Vendor, A=Painting
Punch Category: A (Must be Cleared Before Test)B (Must be Cleared Before System Is Mechanical Complete) C (Can Be Carried Over To
Commissioning Once Agreed)
PL
No.
Isometric / Drawing no. Cat Disc Description
(P-3855 A&B) - Sodium Bisulphate Feed Pump.
01 0.5916.0385 rev.5 B M
P-3855 A&BAs per drawing Item BTPS system
connection plug G 3/8 not provided on the pump casing
during receiving inspection.
02
N014210AAA-ADL-385530-01 Rev.0F
(P-3855A-Discharge)
N014210AAA-ADL-385531-01 Rev.0F
(P-3855B-Discharge)
B MP-3855 A&BItem no: 9 to be as built in pipingisometric drawing as used in the site cap screw 1/2 x
35Long.
03 0.5916.0385 rev.5 B M P-3855 A&BJack bolt not installed
04 0.5916.0385 rev.5 C MP-3855 A&BSubmitted system package does not have
the details of IOM&CM etc.