pl4/psl4 control system · control system is intended to control heaters with built-in high limit...

80
FOR POOL AND SPA EASYTOUCH ® PL4/PSL4 CONTROL SYSTEM IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS USER’S GUIDE

Upload: others

Post on 27-Sep-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

FOR POOL AND SPAEASYTOUCH® PL4/PSL4 CONTROL SYSTEM

IMPORTANT SAFETY INSTRUCTIONSREAD AND FOLLOW ALL INSTRUCTIONSSAVE THESE INSTRUCTIONS

USER’S GUIDE

Page 2: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

P/N 522461 Rev. C 2/2020

Customer Service / Technical Support USA

Phone: (800) 831-7133

8 A.M. to 7:30 P.M. (ET)

Fax: (805) 284-4151

Web sites

visit www.pentairpool.com and staritepool.com

Page 3: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

i

ContentsIMPORTANT WARNING AND SAFETY INSTRUCTIONS ............................................................... iiiEasyTouch PL4/PSL4 Control Systems Kit Contents ........................................................................vAccessory Equipment Part Numbers .................................................................................................vTechnical Support ..............................................................................................................................viSection 1 - EasyTouch PL4/PSL4 Control Systems Overview ....................................................1Features ...........................................................................................................................................1Operating EasyTouch PL4/PSL4 Control Systems ...........................................................................1EasyTouch PL4/PSL4 Control Systems ............................................................................................1EasyTouch PL4/PSL4 Control System Accessories .........................................................................2EasyTouch EasyTouch PL4/PSL4 Control System Power Center .....................................................3EasyTouch PL4/PSL4 Control System Outdoor Control Panel (Controls) .........................................4EasyTouch PL4/PSL4 Control System Indoor Control Panel (Optional) ...........................................7EasyTouch PL4/PSL4 Control System Wireless Controller (Optional) ..............................................8EasyTouch PL4/PSL4 Control System Wireless Controller Changing Battery/Features ...................11EasyTouch PL4/PSL4 Control System Outdoor Control Panel Operating Modes .............................13Quick Start Spa and Pool Operations ................................................................................................14 Heat your spa or pool (manual control) .........................................................................................14 Adjust the water temperature settings ...........................................................................................14 Schedule start and stop times for equipment ................................................................................14Schedules ..........................................................................................................................................14 Heat your spa or pool ....................................................................................................................15Controlling Lights ...............................................................................................................................16 Switch on lights manually and synchronize light colors .................................................................16Schedule start and stop times for equipment ....................................................................................16 Setting the Egg Time Feature (One time schedule) ......................................................................18Section 2 - Setting up the EasyTouch PL4/PSL4 Control Systems ............................................19EasyTouch PL4/PSL4 Menus ............................................................................................................20Main Screen ......................................................................................................................................22Feature Circuits Menu .......................................................................................................................23Lights Menu .......................................................................................................................................23 The Color Swim and Color Set Lighting Features .........................................................................23Setting up Lights ................................................................................................................................24 Assign the Circuit Name and Function .........................................................................................24 Setting up lights .............................................................................................................................20 Setting up IntelliBrite Light Circuits ................................................................................................25Lights Menu .......................................................................................................................................25 Modes (IntelliBrite Color light shows, Color Swim, Color Set) .......................................................25 Modes (Color Swim) ......................................................................................................................25 Modes (Color Set) .........................................................................................................................25 Colors ............................................................................................................................................26 Hold/Recall ....................................................................................................................................26 All On / All Off (Lights Menu) .........................................................................................................26 Sync ................................................................................................................................................26Setting up SAM, SAL, PG2000, Color Wheel Lights .........................................................................27 Config ............................................................................................................................................27Setting up MagicStream Laminars ....................................................................................................28Heat Menu .........................................................................................................................................30 Pool Temp/Src ...............................................................................................................................30 Spa Temp/Src ................................................................................................................................30Delay Cancel Menu ...........................................................................................................................31Schedules Menu ................................................................................................................................32 Using the Schedule menu to program your spa or pool ................................................................32 Using the Egg Timer (countdown) Feature ....................................................................................33Settings Menu: Clock .........................................................................................................................34Settings Menu: IntelliFlo Pump (IntelliPro) ........................................................................................34

Page 4: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

ii

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Contents (Continued)

Settings Menu: IntelliFlo VS .............................................................................................................34Settings Menu: IntelliChlor .................................................................................................................38Settings Menu: IntelliChem ................................................................................................................39Settings Menu: Heat Pump COM (UltraTemp) ..................................................................................41Settings Menu: Circuit Names ...........................................................................................................42 Hi-Temp/Lo-Temp Controls for Single Body System .....................................................................42EasyTouch PL4/PSL4 Circuit Names (Complete List) .......................................................................43Settings Menu: Circuit Functions .......................................................................................................44 Freeze Protection ..........................................................................................................................44 Preset Circuit Function Names (Complete List) ............................................................................45Settings Menu: Custom Names .........................................................................................................46Settings Menu: Valves .......................................................................................................................46Settings Menu: 2-Speed Pump ..........................................................................................................47Settings Menu: Solar .........................................................................................................................47Settings Menu: Delays .......................................................................................................................48Settings Menu: F° / C° (Fahrenheit/Celsius) .....................................................................................49Settings Menu: iS4 Spa-Side Remote Controller ..............................................................................49Settings Menu: QuickTouch (QT4) Wireless Controller .....................................................................50Settings Menu: Man Heat (Off/On) Manual Heat ...............................................................................51Settings Menu: Calibration ................................................................................................................51Settings Menu: Erase EEPROM (Erase System Memory) ................................................................52Settings Menu: Set Password ...........................................................................................................52Settings Menu: Wireless Addr ...........................................................................................................53Settings Menu: Backlight (Wireless Controller) .................................................................................53Settings Menu: Power Save (Wireless Controller) ............................................................................54Spa Side [Off/On] ..............................................................................................................................54Diagnostics Menu: Software Rev ......................................................................................................55Diagnostics Menu: Bootloader Rev ...................................................................................................55Diagnostics Menu: Self Test ..............................................................................................................55Diagnostics Menu: Chlorinator ..........................................................................................................56Diagnostics Menu: Water Temp .........................................................................................................56Diagnostics Menu: Solar Temp ..........................................................................................................56Diagnostics Menu: Air Temp ..............................................................................................................57Diagnostics Menu: Cir Name: [Off/On] .............................................................................................57Diagnostics Menu: Reset System .....................................................................................................57Diagnostics Menu: Flash Update .......................................................................................................57System Wiring Diagram .....................................................................................................................58

Section 3 - Troubleshooting ...........................................................................................................59

Frequently Asked Questions (FAQ) ...............................................................................................59 EasyTouch PL4/PSL4 Control System Error Messages ...............................................................59 Self Test Error Codes ................................................................................................................60 Error Code Table ......................................................................................................................60 IntelliChlor Salt Chlorinator Error Messages .................................................................................61 System Problem Diagnosis (iS4, QT4) ..........................................................................................62 First Time System Start-Up ...........................................................................................................65 Check Electronics ......................................................................................................................65 System Test ...............................................................................................................................65 Testing the Auxiliary Relays ...........................................................................................................65 Setting up the EasyTouch PL4/PSL4 Control System wireless control panel for the first time ......66 Synchronizing control panels .........................................................................................................67Wiring UltraTemp Heat Pump to EasyTouch PL4/PSL4 ....................................................................67Glossary ...........................................................................................................................................68

Page 5: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

iii

IMPORTANT WARNING AND SAFETY INSTRUCTIONS

INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT. This Guide provides installation and operation instructions for the product. Consult Pentair Water Pool and Spa Inc. (“Pentair”) with any questions regarding this prod-uct. This product is intended for use in swimming pool applications only.

Most states and local codes regulate the construction, installation, and operation of public pools and spas, and the construction of residential pools and spas. It is important to comply with these codes, many of which directly regulate the installation and use of this product. Consult your local building and health codes for more information.

Attention User: This Guide contains important information that will help you in operating and maintaining this product. Please retain it for future reference.

Before installing this product, read and follow all safety warning notices and instructions which are included. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call (800) 831-7133 for additional free copies of these instructions.

IMPORTANT NOTICE - Attention Installer: This Installation Guide (“Guide”) contains important information about the installation, operation and safe use of this product. This Guide should be given to the owner and/or operator of this equipment.

Two Speed Pump Controls Notice (Title 20 Compliance) Please read the following important Safety Instructions (See page 47 for pump speed setup) When using two-speed pumps manufactured on or after January 1, 2008, the pump’s default circulation speed MUST be set to the LOWEST SPEED, with a high speed override capability being for a temporary period not to exceed one normal cycle, or two hours, whichever is less.

To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.

Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury.

Do not use this product to control an automatic pool cover. Swimmers may become entrapped underneath the cover.

Except for listed spa-side remote controls, install a minimum of five (5) feet (1.52 m) from the inside wall of the pool and spa.

Water temperature in excess of 100° F (37.7° C) may be hazardous to your health. Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above normal body temperature of 98.6° F (37° C.). Effects of hyperthermia include: (1) Unawareness of impending danger. (2) Failure to perceive heat. (3) Failure to recognize the need to leave the spa. (4) Physical inability to exit the spa. (5) Fetal damage in pregnant women. (6) Unconsciousness resulting in danger of drowning. The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia in hot tubs and

A pool or spa pump must be installed by a qualified pool and spa service professional in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation may create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property.

The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas. This product is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury.

Page 6: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

iv

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

General Installation Information1. All work must be performed by a licensed electrician, and must conform to all national, state, and

local codes.

2. Install to provide drainage of compartment for electrical components.

3. If this system is used to control underwater lighting fixtures, a ground-fault interrupter (GFCI) mustbe provided for these fixtures. Conductors on the load side of the ground-fault circuit-interruptershall not occupy conduit, junction boxes or enclosures containing other conductors unless suchconductors are also protected by a ground-fault circuit-interrupter. Refer to local codes for details.

4. A terminal bar stamped is located inside the supply terminal box. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying this equipment (no smaller than 12 AWG or 3.3 mm). The bonding lug(s) provided on this unit are intended to connect a minimum of one No. 8 AWG for US installation and two No. 6 AWG for Canadian installations solid copper conductor between this unit and any metal equipment, metal enclosures or electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit.

5. The electrical supply for this product must include a suitably rated switch or circuit breaker to openall ungrounded supply conductors to comply with in accordance with the National Electrical Code(NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.1. All applicable local installationcodes and ordinances must also be adhered to. The disconnecting means must be readilyaccessible to the tub occupant but installed at least five (5) feet (1.52 m) from the inside wall of thepool.

6. GAS HEATER: This automation control system is designed to supply high voltage (120 VAC / 240VAC) to a gas heater and override the thermostat in the heater’s control circuit. This automationcontrol system is intended to control gas heaters with a high temperature limit switch(s) safetycircuit.

IMPORTANT WARNING AND SAFETY INSTRUCTIONS

For information about the Virginia Graeme Baker Pool and Spa Safety Act, contact the Consumer Product Safety Commission at (301) 504-7908 or visit www.cpsc.gov.

NOTE: Always turn off all power to the pool pump before installing the main drain cover or working on any suction outlet.

Page 7: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

v

FCC Standard - 47 CFR Part 15, Subpart C (Section 15.247). This version is limited to chapter 1 to chapter 11 by specified firmware controlled in the U.S.A.Instruction to user - This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorientorrelocatethereceivingantenna.• Increasetheseparationbetweentheequipmentandreceiver.• Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.• Consultthedealeroranexperiencedradio/TVtechnicianforhelp.Note: In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of the manufacturer could void the user’s authority to operate this equipment.Canada - Industry Canada (IC) Regulatory Notice: - This device complies with RSS210 of Industry Canada. (1999). Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

RF Exposure Requirements: The antenna(s) used for this device must be installed to provide a separation distance of at least 7.0 inches (20 cm) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. L’antenne (s) utilisé pour cet appareil doit être installé pour fournir une distance de séparation d’au moins (20 cm) à partir de toutes les personnes et ne doit pas être co-localisés ou fonctionner en conjonction avec une autre antenne ou un autre émetteur.

IMPORTANT WARNING AND SAFETY INSTRUCTIONS

Page 8: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

vi

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

EasyTouch PL4/PSL4 Control Systems Model Part Numbers

EasyTouch PL4/PSL4 Control System Model Part Numbers

522352 PL4 - Single Body / Base System (no Indoor Control Panel, no actuators)

522353 PL4 - Single Body / ScreenLogic® Bundle (no Indoor Control Panel, no actuators)

522354 PSL4 - Pool/Spa / Base System (no Indoor Control Panel, two actuators)

522355 PSL4 - Pool/Spa / ScreenLogic® Bundle (no Indoor Control Panel, two actuators)

EasyTouch PL4/PSL4 Control Systems Model Part Numbers (Canada)

522352 PL4 - Single Body / Base System (no Indoor Control Panel, no actuators)

522353 PL4 - Single Body / ScreenLogic® Bundle (no Indoor Control Panel, no actuators)

522354 PSL4 - Pool/Spa / Base System (no Indoor Control Panel, two actuators)

522355 PSL4 - Pool/Spa / ScreenLogic Bundle (no Indoor Control Panel, two actuators)

520911 IntelliChlor Salt Chlorine Generator IC20 cell (Canada)

520912 IntelliChlor Salt Chlorine Generator IC40 cell (Canada)

EasyTouch® PL4/PSL4 Control System Kit Contents

The following items are included in the EasyTouch® PL4/PSL4 Control System kit. The optional IntelliChlor® Salt Chlorine Generator with separate Power Supply may also include the kit.

• EasyTouchPL4/PSL4ControlPanel(mountedinthePowerCenter)• EasyTouchPL4/PSL4PowerCenterenclosure• Twomotorizedvalveactuators(CVA-24TP/N263045)-(PSL4EasyTouchControlSystem

Shared body of water only)• Watersensorwith25footcable,o-ringandhoseclamp(P/N520272)• Airsensorwith25footcable(P/N520272)• EasyTouchPL4/PSL4ControlSystemUser’sGuide(P/N522461)-thismanual

Optional Equipment

• IntelliChlorSaltChlorineGenerator-modelIC20(P/N520554),IC40(P/N520555)• IntelliChem® no-pump (P/N 521357), one-pump (P/N 521356), two-pump (P/N 521355) • IntelliChlorSaltChlorineGeneratorUser’sGuide(P/N520589)• EasyTouchPL4/PSL4ControlSystemPowerCenterInstallationGuide(P/N522460)

EasyTouch Control System PL4/PSL4 Accessory Equipment

iS4 Spa-Side Remote, 4 circuits (P/N 520094)QuickTouch® II four-function wireless remote kit with transceiver assembly (P/N 521245)IntelliChem® Controller (P/N 521356)IntelliChlor® Chlorine Generator Acid Cleaning Kit (P/N 520670)IntelliChlor Salt Chlorinator Spacer pass-through cell for new pool start-up (P/N 520588)

Page 9: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

1

Section 1 EasyTouch® PL4/PSL4 Control Systems Overview

Features• FourSchedules/Programs• AdjustableEggtimerforeasysystemscheduling• TwoFeatureCircuits• IntelliFlo®VSpumpsupport-Supportsuptofour

(4)speedcontrol• iS4andQuickTouch®IIWirelessController

Support• SupportsuptothreeIntelliBrite®LEDColorlights• Valves:Intake/ReturnplusA&Bvalvecircuits• CustomCircuitnaming• ScreenLogic2®Interfacesupport• IndoorControlPanel,WirelessHand-Held

Remote,OutdoorControlPanel• IntelliChem®Controllersupport• IntelliChlor®SaltChlorineGeneratorsupport

(usingexternalIntelliChlorPowerCenter)

Operating EasyTouch PL4/PSL4 Control SystemTheEasyTouchPL4/PSL4ControlSystemisdesignedtoautomaticallycontrolyourpoolandspaequipment,lightsandotheroptionalequipment.Formaintenanceandservicepurposes,usetheMODEbutton,locatedontheoutdoorcontrolpaneltomanualcontrolofallpoolandspaoperations.Formoreinformation,seepage13.TheEasyTouchPL4/PSL4ControlSystemmenufeaturesletyoucreatecustomizedschedulesforyourpoolandspaequipment,heattemperatures,andchlorinationsettingstoswitchonandoffatasetdayandtime.Scheduledautomaticoperationscanbeperformedateithertheoutdoorcontrolpanel,theoptionalindoorcontrolpanelandwirelesscontrolpanel.Formenuoptions,seepage20.

• Spa,ManualHeatFunction• SpaSideControlEnable/Disable• SolarHeatingOption/Support• HeatPumpSupport:RS485Support,

HeatPumpCoolingSupport.• SafetyandFunctionalDelay(s)

andCancelSystemsDelays• RealTimeClock• AssignableCircuitNamesandCustom

CircuitNames• SpecialCircuitTypes/Function• TwoSpeedPumpSupport• English/MetricSupport• SensorCalibration• PasswordProtection

EasyTouch® PL4/PSL4 Control Systems OverviewWelcometotheEasyTouchPL4/PSL4ControlSystems-Nowatyourfingertips,youcanautomaticallycontrolallofyourpoolandspadailyoperationsandoptionalequipmenttheeasyway.

SystemConfiguration

• PoolLite4Circuit(PL4-Fourcircuit,poolonlysystem)• PoolandSpaLite4Circuit(PSL4-Fourcircuit,poolandspasharedequipmentsystem) TheEasyTouchPL4/PSL4controlsystemsprovidesthree(3)auxiliaryrelaycircuitstooperateyourpoolfilterpumpanduptothree(3)lights.Thecontrolsystemisfactoryconfiguredtooperateasa“shared”equipmentsystemora“singlebody”system.

TheEasyTouchPL4/PSL4ControlSystemscancontrolhighvoltage(120VAC/240VAC)equipment,automaticvalveactuators,pumps,lighting,aconventionalheaterorasolarheatingsystem,heatpump,andtheoptionalIntelliChlor®SaltChlorineGeneratorandIntelliChem®WaterChemistryController.

PoolandspaserviceoperationscanbemanuallycontrolledfromtheOutdoorControlPanellocatedinthePowerCenteratthepoolequipmentpad.

AlsoavailablearetheoptionalIndoorControlPanel,WirelessController,iS4Spa-SideRemote,andtheQuickTouch®IIWirelessControllerforcompletecontrolofpoolandspaoperationsfrominsideyouhomeoroutsidearoundyourpoolarea.

Page 10: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

2

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

IntelliChlor® Salt Chlorine Generator - (optional)TheoptionalIntelliChlorSaltChlorineGeneratorsystemallowstheEasyTouchPL4/PSL4ControlSystemsystemtoautomaticallycontrolwatersanitizationbyusingalowconcentrationofsalt(sodiumchloride)inthepoolandspawater.IntelliChlorautomaticallyconvertsthesaltintofreechlorinewhicheliminatebacteriaandalgaeinthepoolandspawater.Thechlorinewillthenrevertbacktosodiumchlorideafterkillingthebacteria.Theoutcomeofthiscontinuouscycle,practicallyeliminatestheneedtousesanitizingchemicalsinthepool/spawater.IntelliChlormodelIC20(P/N520554/520556)isdesignedforswimmingpoolsupto20,000U.S.gallons(75,000liters).ModelIC40(P/N520555/520556)isdesignedforswimmingpoolsupto40,000U.S.gallons(151,000liters).

IntelliChem® Chemical Controller (optional)TheoptionalIntelliChem®ControllerisapHandORPsensingdevicethatdispensescorrectamountofchlorineorbromine,muriaticacidorCO2gas.IntelliChemprovidescontinualanalysisofyourswimmingpoolwatersanitationandpHlevels,providingreal-timestatusinformationtodispensetheproperamountofmuriaticacid(pHreducer)andchlorineorbromineforthecorrectsanitizationandpHbalance.IntelliChemControlleroperateswithorwithoutasaltchlorinegeneratortoprovideaself-replenishingsupplyofchlorinegeneratedfromsalt.IntelliChemControllercanalsoconnecttocarbondioxide(CO2)liquidgastankstolowerpHinyourswimmingpoolwater.WhenCO2dissolvesintowateritproducesweakneutralbicarbonatesaltswhichreducespH.CO2isenvironmentallyfriendlyandproducesnosecondarypollutionintothetreated waterbysaltssuchaschloridesorsulfates.IntelliChemalsosupportsIntelliChlor® SaltChlorineGeneratortohelpmanageyourpoolwatersanitizerlevels.

Indoor Control Panel (optional)TheEasyTouchPL4/PSL4IndoorControlPanelprovidesyouwithonetouchautomaticcontrolforallofyourpoolandspadailyoperationsfrominsideyourhome.TheindoorcontrolpanelisconnectedtothePowerCenterenclosure.

iS4 Spa-Side Remote (optional) TheiS4Spa-Sideremotecontrollerisadouble-insulated,waterproofdevicethatisUL(1563)listedforinstallationatthewater’sedge.Installedabovethewaterlineofthespawall,orinthedeckwithinarm’sreachofaspaoccupant.TheiS4cancontrolfourcircuitsfromthe spalocation.Usedforactivatingspacirculationandanythreeauxiliarypiecesofequipment(suchaslights,jetpump,airblower,etc.).TheredstatusLEDindicatorglowssteadywheninSpamodeandflasheswhilethespaisheating.FormoreaboutassigningcircuitstotheiS4buttons,referto“SettingsMenu:iS4Spa-SideRemotecontroller,”onpage50.Therearetwoinstallationchoicesasshown.

QuickTouch® II Wireless Controller (optional)TheoptionalhandheldQuickTouch®IIWirelessControllercancontroluptofourpool/spacircuits.Eachofthefourfunctionsontheremotehasanonandanoffbutton.Formoreinformation,seepage50.

QuickTouchIIWirelessRemote (P/N521245)

Wireless Control Panel (optional)TheEasyTouchPL4/PSL4ControlSystemWirelessControllerprovidescompletecontrolofpoolandspaoperationsfrominsideyouhomeoroutsidearoundyourpoolarea.Formoreinformation,seepage55and65.

EasyTouch® PL4/PSL4 Control System Accessories

IntelliChlorSaltChlorineGenerator

IntelliChemChemicalController

iS4Spa-SideRemote (P/N521885)Optional

Page 11: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

3

EasyTouch® PL4/PSL4 Control System Power Center

•Pumps Filter,Cleaner,SpaJet,

1.5HP120VAC 3HP277VAC 20FLA/120LRA,

120VAC 17FLA/102LRA,

277VAC

• Relays 25AMP,277VAC

•Pool/Spa Lights 1.5KW120VACTungsten 4.8KW240VACTungsten 20AMP,277VACBallast

• Pool/Spa Valve Suctionandreturn. 24VACvalveactuator,sharedequipmentonly

• Auxiliary Valves (Qty.2)AandB

• Heater Gasorelectric

• Heat Pump (UltraTemp®) Heatingorcooling

• IntelliFlo® Pumps:

VS Pump P/N011018

TemperatureSensors (Water,AirandSolar)

ElectricHeater-ConnectstoplugJ16onEasyTouchPL4/PSL4ControlSystem

circuitboard

IndoorControlPanel (3AUXcircuits) (P/N522465)Optional

LowVoltage(DC) circuitbreakers

EasyTouchPL4/PSL4ControlSystem OutdoorControlPanel(notshown)

ConnectstoOutdoorControlPanelRS-485COMport,locatedonEasyTouchPL4/PSL4ControlSystemPowerCentermaincircuitboard

Wireless Controller (3 AUX circuits) (P/N 522464) Optional

• IntelliChlor®SaltChlorineGenerator(withseparatePowerCenter):

• IC20P/N520554520556• IC40P/N520555/520556(seepage26)• IntelliChem®Controller:P/N521357(no

pump),P/N521356(onepump),P/N521355(twopump).Seepage39.

QuickTouch®II WirelessRemote (P/N521245)Optional

iS4Spa-SideRemote (P/N521885)Optional

Pantone Colors:429 Buttons431 Background

SHOWN WITH 1SERIAL COM PORT EXPANSIONCIRCUIT BOARD (OPTION)P/N 520818

EasyTouchPL4/PSL4ControlSystemPowerCenter (Frontpanelandoutdoorcontrolpanelnotshown)

QuickTouch®II WirelessController TransceiverAntenna

Page 12: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

4

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

EasyTouch® PL4/PSL4 Control Systems Outdoor Control PanelYoucanfullyautomateyourpool,spa,andlightingoperationsfromtheEasyTouchPL4/PSL4ControlSystemsOutdoorControlPanelorfromtheoptionalIndoorControlPanelandWirelessController.Formaintenanceandservicepurposes,usingthe“Mode”button,thesystemcanbeswitchedfrom“Auto”mode(normaloperatingmode)to“Service”modeformanualoperationandservicepurposes.Usingtheoutdoorcontrolpanelbuttonsyoucanmanuallyoverrideanyautomaticsettings.Formoreinformation,seepage13. FromtheEasyTouchPL4/PSL4ControlSystemsmenuyoucreatecustomizedschedulesforyourpoolandspaequipment,heattemperatures,andchlorinationsettingstoswitchonandoffatasetdayandtime.Scheduledautomaticoperationscanbeperformedateithertheoutdoorcontrolpanel,theoptionalindoorcontrolpanelandwirelesscontrolpanel.Formenuoptions,referto“EasyTouchPL4/PSL4ControlSystemsMenus,”onpage20.Thefollowingdescribestheoutdoorcontrolpanelbuttons,andLEDindicators.

Ifrequired,theoptionalEasyTouchPL4/PSL4outdoorcontrolpanelcanbepasswordprotected.Toaccessapasswordprotectedcontrolpanel,simplyentertheassignedthefourdigitpassword(seepage52).

EasyTouch PL4/PSL4 Control System Outdoor Control Panel Controls

Liquid Crystal Display (LCD):Themainsystemdisplayconsistsofa16x4alphanumericcharacterLCDwithELbacklightingforeasyviewingofthemenuitemsandstatusmessages.PresstheMenubuttontwicetorefreshthedisplay.

Up/Down buttons:UsetheUpandDownbuttonstoscrollthroughthemainmenuitemsandtoadjustorchangesettings.UsethesebuttonsafterpressingtheMenubuttontoaccessthemainmenuitems.Whileeditingsettings,pressandholdtheUporDownbuttontofastforwardorfastreversethroughsettingsandvalues.

Left button: WheninpoolorspamodeusetheLeft and Right buttontoadjustthetemperaturelevel.PresstheLeftbuttontolowerthesetpointwatertemperature.PresstheFilter Pump (F) button todisplaythecurrentwatertemperature.UsetheLeftbuttontoscrollthroughsub-menuselections,settingandvalues.Whileeditingsettings,pressandholdtheLeftbuttontofastreversethroughsettingsandvalues.

EasyTouchPL4/PSL4ControlSystemOutdoorControlPanel(LocatedinsystemPowerCenter)

1

2

3

AUTO HEATERSPA 85°F / 100°F AIR 70°F MON 09:30 AM

1 2

3 4 5

6

7 8

9

11 12

13

10

Page 13: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

5

EasyTouch® PL4/PSL4 Control System Outdoor Control Panel Controls (Continued)

Menu/back button (Power On - Wireless Controller): Usethisbuttontoaccess,saveandexitfromacurrentmenuorsub-menusettings.Also,whileinamenuorsub-menuitems,usethisbuttontogobacktoapreviousmenuleveloritem.Ifnomenuactivityisdetectedafterfiveminutes,themainscreenisdisplayed.Allmenusettingsarepermanentlysavedandretainedinthecontrolpanelevenafterpowerisremovedfromthecontrolpanel.Controlpanelbuttonsaredisabledwhileinthemenumode.

Right button:WheninpoolorspamodeusetheLeftandRightbuttontoadjustthetemperaturelevel.PresstheRightbuttontoraisethesetpointwatertemperature.PresstheFilterPump(F)buttontodisplaythecurrentwatertemperature.UsetheRightbuttontoselectasub-menuitemforediting.AfterpressingtheMenubuttontoaccessthemainmenuitems,usetheRightbuttontoselectthemenuitemandaccessthesub-menuitemsforadjustment.Whileeditingasettings,pressandholdtheRightbuttontofastforwardthroughsettingsandvalues.

Filter Pump (F) button/LED: Switchesasinglespeedfilterpumponandoffin“Pool”or“Spa”mode.PresstheValves(V)buttontotogglebetween“Pool”and“Spa”modeandrotatevalves.If“Heater”isenabledinthe“Heat”menu(seepage30),pressingtheFilterPumpbuttonwillalsoenabletheselectedheatsource(Heater/SolarLEDon).Thedefaulttimebeforethefilterpumpwillswitchoffis12hours.Thisbuttonoperatesin“Auto”or“Service”mode.

Single-Speed Filter Pump: Ifthepumpiscurrentlyoff,presstheFilterPumpbutton(LEDon)toswitchthepumpon.PresstheFilterPumpbuttonagaintoswitchthepumpoff.However,iftheheaterisoperating,andadelayisenabledforvalves,thisallowstheheatertocooldown(heatercool-down),thenwhenyoupresstheFbuttontoswitchoffthepump,onlytheheaterwillturnoff,thenthefilterpumpwillautomaticallyswitchoffafter10minutestoallowtheheatertocooldown.PentairWaterPoolandSpaheatersdonotrequireacooldowntime.Tooverridethe“heatercool-down,”presstheFilterPumpbuttonagaintoswitchoffthepump.

Two-Speed Filter Pump: PresstheFilterPumpbutton(LEDon)toswitchthetwo-speedpumponinhighspeed.Ifyouswitchthepumpofftolowspeedshortlyafterswitchingittohighspeed,thefilterpumpwillautomaticallyremaininhighspeedforafewminutesbeforeswitchingbacktolowspeedtoallowthepumptoprimeandestablishnormalwaterflow.Inordertousethe“2-SpeedPump”menuassignments(seepage47),the2-SpeedrelayoptionmustbeinstalledintheEasyTouchPL4/PSL4ControlSystemPowerCenter.

Freeze Protection:Thisfunctionprotectsthepool,plumbing,andequipmentagainstfreezedamage.Iftheoutsideairtemperaturesensorfallsbelow36°F,“FreezeProtection”isactivatedandtheFilterPumprelayisswitchedontocirculatethepoolwater.Toenablefreezeprotectionforacircuit,seeSettingsMenu:CircuitFunction,onpage44.

Mode button: UsethisbuttonforservicepurposestomanuallycontroltheEasyTouchPL4/PSL4ControlSystem.Pressthisbuttononceactivate“Service”mode,toallowAUXcircuitbuttons,FilterPump,Valves,HeaterandSolarbuttonstobeoperatedmanually.Pressthebuttonasecondtimetoenable“Timeout”mode.Thismodeissimilarto“Service”modeexceptthatthesystemwillautomaticallyreturntonormaloperation(Auto)afterthreehours.Pressthebuttonathirdtimetoreturnthesystemto“AUTO”mode.ThecurrentoperatingstatusisshownintheLCDdisplay.Themenubuttons,remotecontrollers,andmenuscheduledoperationsaredisabled(exceptforswitchingoffequipmentmanuallyforemergencies)whilethesystemisin“Service”mode.

Auto:InAuto (automatic)modethesystemisinnormaloperatingmodeandiscontrolledbythemaincontrolpanelLCDmenufeatures.Service: Usethismodetoservicepoolequipmentandtooperateequipmentmanually.Timeout: Samefunctionalityas“Service”mode,exceptthatthesystemwillautomaticallyreturntonormaloperation(Auto)afterthreehours.

MODE

4

5

6

7

Page 14: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

6

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

EasyTouch® PL4/PSL4 Control System Outdoor Control Panel Controls (Continued)

Valves (V) - (Pool/Spa/Fill (Spillway)/Drain) button: Wheninnormaloperatingmode,theValves(V)buttonisin“Pool”mode.Inthismodethevalvesareautomaticallyrotatedsothatonlythepoolwateriscirculatedthroughthesystemandthefilterpumpisactivated.Pressingthisbuttononceenables“Spa”mode,andactivatesthefilterpumptocirculateonlyspawaterthroughthesystem.“Fill/Spillway”and“Drain”modecanonlybeusedwhilein“Service”mode(SeeModebuttonfordetails).“Fill/Spillway”and“Drain”modeareusedwhencleaningthespa.PressingtheValves(V)buttonagainreturnsthesystemto“Pool”mode.Notethatthefilterpumpwillswitchoffwhilethepool/spavalvesarerotatingintoposition.ThecurrentoperatingmodeisshownintheLCDdisplay. Note: The Valves button (Pool, Spa, Fill (Spillway), Drain) button has no function in “Pool only” or “Spa only” systems. For PL4/PLS4 Control System single body system, “Pool” and “Spa” modes are Lo- Temp (Pool) and Hi-Temp (Spa) temperature controls. For more information, see “Hi-Temp/Lo-Temp Controls for Single Body Systems,” page 42.

V

11

12

13

10

9

8

Aux 1-3 buttons/LEDs: Auxiliaryoutputcircuitbuttonsoperatethepoolandspasystemvalves,lightsandotherequipment.Theseauxiliarycircuitsareassignedinthe“CircuitFunction”menu,seepage46fordetails.Therearethreeauxiliarycircuits(AUX1-3)onthePL4/PLS4ControlSystemOutdoorControlPanel.Labelscanbeaffixednexttoeachauxiliarybuttontoidentifythecircuitfunction.Whenanauxiliarycircuitisactivatedorthebuttonispressed,theLEDison.Pressinganauxiliarycircuitbuttonwillactivatethecorrespondingcircuitineither“Auto”or“Service”mode.Whenacircuitrelayisswitchedonmanually,itremainsonuntileitheryouswitchitoffmanually,orthenexttimetherelayisscheduledtobeswitchedoff.Forexample,ifthefilterpumpisscheduledtoautomaticallyrunfrom9:00AMto5:00PMdailythenthefilterpumpisswitchedonmanuallyat9:00PM(scheduleinterrupted),itwillruncontinuouslyuntilthenextdayat6:00PMthenswitchoff.Theschedulewillthencontinuefromthenon.Note:Acircuitturnedonmanuallywillrunaslongasthe“EggTimer”issetfordefault12hours.

Heater (Flame) button/LED: Thisbuttonisonlyusedin“Service”modeformanualheatonandoffcontrol.TheHeaterLEDwillbeonif“Heater”isenabledinthe“Heat”menusetting(seepage30).Switchingtheheateronautomaticallycontrolstheoutputbetweena“forcedoff”stateandanormalautomaticthermostaticcontroloperatingstate.Theheaterwillcontinueheatingthewateruntiltheheater’scurrenthighestsetpointtemperaturetriggerstheheatersensor(approximately104°F).NotethattheHeaterbuttondoesnotactivatethepump.Donotactivatetheheaterwithoutrunningthepump.Theheaterwillnotrunifwaterflowisnotdetected.

Solar (Sun) button/LED: Insolarmodethisbuttonisonlyusedin“Service”modeformanualsolarheatonandoffcontrol.TheSolarLEDwillbeonif“Solar”isenabledinthe“Heat”menusetting.Solarmustalsobeenabledinthe“Solar”menu.UsetheSolarbuttontomanuallyswitchtheheatercontroloutputbetweena“forcedoff”stateandanormalautomaticthermostaticcontroloperatingstate.Whenthisbuttonispressedthesolarrelayisswitchedontoactivateaboosterpump,ifinstalled,andactivatesvalvestorotatetodivertwaterthroughsolarheatingpanels.

Reset button:PressthisbuttontoreinitializetheEasyTouchPL4/PSL4ControlSystemoutdoorcontrolpanel.

Low voltage circuit breakers:ThreeampcircuitbreakersprotectthelowvoltageEasyTouchPL4/PSL4ControlSystemmaincircuitboardcircuits,relaysandvalves.

Page 15: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

7

AUTO HEATERSPA 85°F / 100°F AIR 70°F FRZ MON 09:30 AM

EasyTouch® PL4/PSL4 Control System Indoor Control Panel (Optional)

TheEasyTouchPL4/PSL4ControlSystemIndoorControlPanelallowsyoutocontrolthepoolandspadailyoperationsfromaroundyourpoolareaorinsideyourhome.Usethe“P”(Pool)and“Spa”(Pool)buttonstoheatandfilteryourpoolandspa.TheindoorcontrolpanelconnectstotheEasyTouchPL4/PSL4ControlSystemmaincircuitboardlocatedinthePowerCenter.

EasyTouchPL4/PSL4ControlSystemIndoorControlPanel

Spa (Hi-Temp) Button:Switchesthefilterpumpon,rotatesvalveactuator(toisolatespawaterfrompoolwater),andswitchestheheateron.Hi-Temp(singlebodysystem)setsthehightemperature settingsforthespa.Pool (Lo-Temp) Button:

Switchesthefilterpumpon,rotatesvalve

actuator(toisolatepoolwaterfromspawater),

andswitchesheateron. Lo-Temp(singlebodysystem)setsthelow

temperature settingsforthepool.

SetTemperaturebuttons, seepage3.

CircuitLED.Circuitnamelabel.

Three(3)userdefinedauxiliarycircuits.But-tonsswitchtheas-signedcircuitfunctionon/off. (Defaulttimeisa12hourtime-out).

(Leftarrowbutton)Lowersettemperature

(Rightarrowbutton) Raisesettemperature

AUTO (Automatic): Thesystemisinnormaloperatingmode. Scheduledprogramswillrunautomatically.SERVICEorTIMEOUTmodearedisplayedwhenthesystemisbeingserviced.ThesemodesareactivatedfromtheOutdoorControlPanel.HEATER:Heaterisswitchedon.DisplayswhenthePool(P)orSpabuttonispressed.ForpooloperationstheheatsourcemustbeenabledintheHeatmenu(seepage30).Displays“Solar”or“SolarPrf”ifsolarisenabled.Theheaterisactivewhenthesettemperatureishigherthanthewatertemperature.Theheaterwillswitchoffwhenthewatertemperaturerisesabovethesettemperature.SPA (Hi-T) or POOL (LO-T) :DisplayswhentheSpa/HI-TorPool/LO-Tbuttonispressedtorotatevalveactuatorsandactivatethefilterpumpandheater.Thislineonthescreenisblankwhennospaorpoolfunctionisactive.Note:DependingontheconfigurationofthePL4/PLS4ControlSystem,thescreendisplaysSPA(sharedequipment-EasyTouchPSL4Control System),HI-T(singlebodyofwater-EasyTouchPL4ControlSystem). system),POOL(sharedequipment),LO-T(singlebodyofwatersystem).85° F / 100° F:Displaystheactualspaorpoolwatertemperature (85°F)andthesetpointtemperature(100°F)assetintheHeatermenu.DegreeunitsaredisplayedineitherFahrenheitorCelsius.AIR:Displaystheactualoutsideairtemperature(70°F)asreadbytheairsensorlocatednearthePL4/PLS4ControlSystemPowerCenter.DegreeunitsaredisplayedineitherFahrenheitorCelsius(seepage49).FRZ:Displayswhenfreezeprotectionisactive.Toprotectpoolsystemequipment,freezeprotectionmustbeenabledforthefilterpumpcircuit.Iftheoutsideairtemperaturesensordetectsthetemperatureisgettingclosetofreezingpoint(below36°F(2°C)),thefreezeprotectionfeatureswitchesonthefilterpumpcircuittocirculatewaterthroughthesystem.Formoreinformation,seepage44.DEL:Displayswhen“DelayCancel”isactive.Formoreinformation,seepage31.Date and Time:DisplaysthePL4/PLS4ControlSystemdayandtimeasspecifiedinthe“Clock”menusetting(seepage34).

Page 16: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

8

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Pantone Colors:429 Buttons431 Background

EasyTouch® PL4/PSL4 Control System Wireless Controller (Optional)

TheEasyTouchPL4/PSL4ControlSystemWirelessControllerallowsyoutocontrolyourpoolandspadailyoperationsfromaroundyourpoolareaorinsideyourhome.Usethe“P”(Pool)and“Spa”(Pool)buttonstoheatandfilteryourpoolandspa.ThewirelesscontrollercommunicateswiththeoutdoorcontrolpanelviathetransceiverlocatednearthePowerCenter.

Spa (Hi-Temp) Button:Switchesthefilterpumpon,rotatesvalveactuator(toisolatespawaterfrompoolwater),andswitchestheheateron.Hi-Temp(singlebodysystem)setsthehightemperature settingsforthespa.

Three(3)userdefinedauxil-iarycircuits.Buttonsswitchtheassignedcircuitfunctionon/off(Defaulttimeisa12hourtime-out).

CircuitLED.Circuitnamelabel.

AUTO (Automatic): Thesystemisinnormaloperatingmode. Scheduledprogramswillrunautomatically.SERVICEorTIMEOUTmodearedisplayedwhenthesystemisbeingserviced.ThesemodesareactivatedfromtheOutdoorControlPanel.HEATER:Heaterisswitchedon.DisplayswhenthePool(P)orSpabuttonispressed.ForpooloperationstheheatsourcemustbeenabledintheHeatmenu(seepage30).Displays“Solar”or“SolarPrf”ifsolarisenabled.Theheaterisactivewhenthesettemperatureishigherthanthewatertemperature.Theheaterwillswitchoffwhenthewatertemperaturerisesabovethesettemperature.SPA (Hi-T) or POOL (LO-T) :DisplayswhentheSpa/HI-TorPool/LO-Tbuttonispressedtorotatevalveactuatorsandactivatethefilterpumpandheater.Thislineonthescreenisblankwhennospaorpoolfunctionisactive.Note:DependingontheconfigurationofthePL4/PLS4ControlSystem,thescreendisplaysSPA(sharedequipment-EasyTouchPSL4ControlSystem),HI-T(singlebodyofwatersystem-EasyTouchPL4ControlSystem),POOL(sharedequipment),LO-T(singlebodyofwatersystem).85° F / 100° F:Displaystheactualspaorpoolwatertemperature (85°F)andthesetpointtemperature(100°F)assetintheHeatermenu.DegreeunitsaredisplayedineitherFahrenheitorCelsius.AIR:Displaystheactualoutsideairtemperature(70°F)asreadbytheairsensorlocatednearthePL4/PLS4ControlSystemPowerCenter.DegreeunitsaredisplayedineitherFahrenheitorCelsius(seepage51).FRZ:Displayswhenfreezeprotectionisactive.Toprotectpoolsystemequipment,freezeprotectionmustbeenabledforthefilterpumpcircuit.Iftheoutsideairtemperaturesensordetectsthetemperatureisgettingclosetofreezingpoint(below36°F(2°C)),thefreezeprotectionfeatureswitchesonthefilterpumpcircuittocirculatewaterthroughthesystem.Formoreinformation,seepage46.DEL:Displayswhen“DelayCancel”isactive.Formoreinformation,seepage31.Date and Time:DisplaysthePL4/PLS4ControlSystemdayandtimeasspecifiedinthe“Clock”menusetting(seepage34). Battery icon:Displaystheavailablebatterypowerusageforthedevice. Seepage11fordetails.

(Rightarrowbutton) Raisesettemperature

AUTO HEATERSPA 85°F / 100°F AIR 70°FMON 09:30 AM

EasyTouch®PL4/PSL4ControlSystemWirelessController

Pool (Lo-Temp) Button:Switchesthefilterpump

on,rotatesvalveactuator(toisolatepoolwaterfromspawater),andswitches

heateron. Lo-Temp(singlebody

system) setsthelowtemperature

settingsforthepool.

SetTemperaturebuttons, seepage3.

(Leftarrowbutton)Lowersettemperature

Page 17: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

9

EasyTouch® PL4/PSL4 Control System Indoor Control Panel and Wireless Controller Buttons

Spa button/LED:Forspaoperations.PresstheSpabuttontoactivatethefilterpumptorotatethepool/spavalveactuatorsandcirculatethespawater(LEDon).Pressthebuttonagaintoswitchthefilterpumpoff(LEDoff).Whilethevalvesarerotatingintopositionthefilterpumpwillswitchoff.Forserviceortestingpurposes,iftheheaterisenabledintheHeatmenu,pressingthisbuttonwillalsoactivatetheheater.Fornormalspaoperationstheheaterisautomaticallyswitchedonwiththefilterpump(seeManHeatpage42)regardlessoftheHeatmenusetting.Whenthisbuttonispressedthecircuitisactivated,theLEDisonand“SPA”isdisplayedonthescreenwiththecurrentandsetpointwatertemperatures.Oncethefilterpumpisswitchedonitwillrunfor12hoursunlessitisswitchedoff.Whenthisbuttonispressed,theLEDsontheoutdoorcontrolpanelFilterPump(F)button,Valves(V)button,andHeaterbutton(ifenabledintheHeatmenu)willbeon.Ifthisdisplaylineisblank,itindicatesnospaorpoolfunctioniscurrentlyactive.Pool Button:Forpooloperations.PressthePool(P)buttontoactivatethefilterpump,rotatethepool/spavalveactuatorsandcirculatethepoolwaterandswitchontheheater(ifenabledintheHeatmenu).Pressthebuttonagaintoswitchthefilterpumpoff.Whilethevalvesarerotatingintopositionthefilterpumpwillswitchoff.Whenthisbuttonispressedthecircuitisactivatedand“POOL”isdisplayedonthescreenwithactualandsetpointwatertemperatures.Whenthefilterpumpisswitchedonitwillrunfor12hoursunlessitisswitchedoff.Whenthisbuttonispressed,theLEDsontheoutdoorcontrolpanelFilterPump(F)button,Valves(V)button,andHeaterbutton(ifenabledintheHeatmenu)willbeon.Ifthisdisplaylineisblank,itindicatesnopoolorspafunctioniscurrentlyactive.

Notes about Freeze Protection:Thisfunctionprotectsthepool,plumbing,andequipmentagainstfreezedamage.Iftheoutsideairtemperaturesensorfallsbelow36°F(2°C),“FreezeProtection”isactivatedandtheFilterPumprelayisswitchedontocirculatethepoolwater.Toenablefreezeprotectionforacircuit,see“SettingsMenu:CircuitFunctions, ”onpage44.

Liquid Crystal Display (LCD):Themainsystemdisplayconsistsofa16x4alphanumericcharacterLCDwithELbacklightingforeasyviewingofthemenuitems,andstatusmessages.PresstheMenubuttontwicetorefreshthedisplay.

• Single-Speed Filter Pump: Ifthepumpiscurrentlyoff,pressthePoolbuttontoswitchthepumpon.PressthePoolbuttonagaintoswitchthepumpoff.However,iftheheaterisoperating,andadelayisenabledforvalves,thisallowstheheatertocooldown(heatercool-down),thenwhenyoupressthePoolbuttontoswitchoffthepump,onlytheheaterwillturnoff,thenthefilterpumpwillautomaticallyswitchoffafter10minutestoallowtheheatertocooldown.Tooverridethe“heatercool-down,”pressthePool buttonagaintoswitchoffthepump.

• Two-Speed Filter Pump: PressthePoolbuttontoswitchthetwo-speedpumponinhighspeed.PressthePoolbuttonagaintorunthepumpinlowspeed.Inordertousethe“2-SpeedPump”menuassignments(seepage36),the2-SpeedrelayoptionmustbeinstalledintheEasyTouchPowerCenter.

Left button: Wheninpoolorspamode,presstheLeftbuttontolowerthesetpointwatertemperature.PresstheSpaorPool(UparrowP)button(page8)todisplaythecurrentwatertemperature.Whileinthemainmenu,presstheLeftbuttontoscrollthroughsub-menuselections,settingandvalues.Whileeditingsettings,pressandholdtheLeftbuttontofastreversethroughsettingsandvalues.

s

P

Page 18: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

10

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

EasyTouch PL4/PSL4 Control System Indoor Control Panel and Wireless Controller Buttons (Continued)

Menu/Back button: PresstheMenu/Backbuttontoaccess,saveandexitthemenusettings.Usethisbuttontoexitfrommainmenuorsub-menuitems.PressingtheMenu/Backbuttonwhileinamenuitemwillreturntothemainstatusscreen.Ifnomenuactivityisdetectedafterfiveminutes,themainscreenisdisplayed.Allmenusettingsarepermanentlysavedandretainedinthecontrolpanelevenafterpowerisremovedfromthecontrolpanel.Controlpanelbuttonsaredisabledwhileinmenumode.

AUX (1-3) buttons/LEDs: Theauxiliaryoutputcircuitbuttonsoperatethepoolandspasystemvalveactuators,lightsandotherequipment.Theauxiliary(AUX)relaycircuitsareassignedinthe“CircuitFunctions”menu,seepage46fordetails.Therearethreeauxiliarycircuits(AUX1-3)ontheEasyTouchPL4/PSL4ControlSystemIndoorControlPanel.Labelscanbeaffixednexttoeachauxiliarybuttontoidentifythecircuitfunction.Whenanauxiliarycircuitisactivatedorthebuttonispressed,theLEDison.Pressinganauxiliarycircuitbuttonwillactivatethecorrespondingcircuitineither“Auto”or“Service”mode.Whenacircuitrelayisswitchedonmanually,itremainsonuntileitheryouswitchitoffmanually,orthenexttimetherelayisscheduledtobeswitchedoff.Forexample,ifthefilterpumpisscheduledtoautomaticallyrunfrom9:00AMto5:00PMdailythenthefilterpumpisswitchedonmanuallyat9:00PM,itwillruncontinuouslyuntilthenextdayat5:00PMthenswitchoff.Theschedulewillthencontinuefromthenon.AUXbuttonsaredisabledwhileinthemainmenu.Note: A circuit turned on manually will run as long as the “Egg Timer” is set for default 12 hours.

Power ON, Menu/Back button (Wireless Controller): UsethisbuttontopowerontheEasyTouchPL4/PSL4WirelessController.Iftherehasbeennobuttonactivityfor60seconds(seepage54).TheMenu/Backbuttontoaccess,saveandexitthesystemmenusettings.Usethisbuttontoexitfrommainmenuorsub-menuitems.PressingtheMenu/Backbuttonwhileinamenuitemwillreturntothemainstatusscreen.Ifnomenuactivityisdetectedafterfiveminutes,themainscreenisdisplayed.Allmenusettingsarepermanentlysavedandretainedinthecontrolpanelevenafterpowerisremovedfromthecontrolpanel.Controlpanelbuttonsaredisabledwhilein“menu”mode.

POWER ONMENU

Right button:WheninpoolorspamodeusetheLeftandRightbuttontoadjustthetemperaturelevel.PresstheRightbuttontoraisethesetpointwatertemperature.PresstheFilterPump(F)buttontodisplaythecurrentwatertemperature.UsetheRightbuttontoselectasub-menuitemforediting.AfterpressingtheMenubuttontoaccessthemainmenuitems,usetheRightbuttontoselectthemenuitemandaccessthesub-menuitemsforadjustment.Whileeditingasettings,pressandholdtheRightbuttontofastforwardthroughsettingsandvalues.

Up/Down buttons:UsetheUpandDownbuttonstoscrollthroughthemainmenuitemsandtoadjustorchangesettings.UsethesebuttonsafterpressingtheMenubuttontoaccessthemainmenuitems.Whileeditingsettings,pressandholdtheUporDownbuttontofastforwardorfastreversethroughsettingsandvalues.

P

Page 19: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

11

Battery OverviewTheaveragelifefortheEasyTouch®ControlSystemWirelessControllerbatteriescanlastthesummerseasonwithnormaluse.Batterylifevariesdependingonthetypeofbatteriesusedandtheamountofusage.Thefollowingbatterytypesarecompatiblewiththewirelesscontroller:

• AA-sizealkalinebattery(fourprovidedinthekit)• AA-sizeNi-MHrechargeablebattery(fourpurchasedseparately)

Safety Precautions when using batteriesReadthefollowingimportantinformationbeforeinstallingbatteriesintothewirelesscontroller.

• Neverusebatterieswithsplitorpeelingoutercasings• Neverusecombinationsofdifferenttypesofbatteriesornewandusedbatteriestogether• DonotusemanganeseorNi-Cdbatteries• Ensurethatbatteriespolesareclean.Dirtypolescanshortenbatterylife• ThetimeforwhichAA-sizealkalinebatteriescanbeusedvarydependingonthebrand.Somebrands

mayprovidelesspowerthanothers.NotethatthetimeAlkalinebatteriescanbeuseddecreasesincoldconditions(0°Cto10°C(32°Fto50°F)).Therefore,itisrecommendedtouseAA-sizeNi-MHbatteriesintheunit.

• Whenfirstpurchased,orifleftunusedforalongperiod,theamountoftimethattheAA-sizealkaline,Ni-MH,orrechargeablebatteriescanbeused,maybeshortened.

Checking the battery chargeAcheckbatterystatusicondisplaysonthemainscreenofthewirelesscontroller.Thecheckbatteryiconislocatedinthelowerrightcornerofthemainscreen.

EasyTouch® PL4/PLS4 Control System Wireless Controller Power Saving Options and Changing Batteries

AUTO HEATERSPA 85°F / 100°F AIR 70°FMON 09:30 AM

Power Save Options

Usethepowersavefunctiontoreducepowerconsumptionandextendbatterylife.Thepowersaveoptionsare:

• Idle Time:Ifthereisnocontrolpanelactivity,theidletimecanbesetto60seconds(default),30seconds,orfiveminutesbeforeitshutsdown.Thedefaulttimeis60seconds.Forinformationaboutaccessingtheidletimeoptionsmenu,seepage54.

Note: If the unit is not used for 60 seconds the power save function switches off the unit. To switch the unit on, press the POWER ON button (see page 10).

Backlight Options

Usethebacklightontimepowersaveoptionstoreducepowerconsumptionandextendbatterylife.ToaccesstheBacklightoptionsmenu,seepage48.Thebacklightoptionsare:

• On Time:Backlightisonfor60seconds,30seconds,fiveminutes,oroff.Thedefaultsettingis30seconds.

• Brightness:Backlightbrightnesscanbesettolow,mediumorhigh.Thedefaultsettingismedium.

Battery Replacement

Amplebatterycharge.

Sufficient charge left in the batteries to operate the unit. The unit’s estimated battery life varies greatly depending on use and backlight display time (see page 12).

Batteries are depleted. Before the batteries are completely depleted this icon will start flashing, indicating that the LCD will shortly go blank and the wireless controller will stop working. Replace or recharge the batteries. Depending on the type of batteries installed, this icon may display more quickly.

Check battery icons

Page 20: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

12

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Installing BatteriesThePL4/PLS4ControlSystem WirelessControllerisshippedwithfourAA-sizealkalinebatteries.Beforeusingtheunitinstallthebatteries.

Toinstallbatteries:

1. PlacethePL4/PLS4ControlSystem WirelessControllerfacedownonaflatcleansurface.Removethesixscrewssecuringthebatterycover.Setthecoveraside.

2. Loadthefourbatteriesintothebatterycompartment.Orientthepositivepolarityendofeachbatteryasshownbelow.

3. Installthebatterycoverandsecurewiththesixscrews.Makesurethatthebatterycoverissecureandthatallthescrewsarehandtightened.CAUTION-DONOTOVERTIGHTENTHESCREWS.OVERTIGHTENINGTHESCREWSCANDAMAGETHEUNIT.

4. Poweruptheunit:Toswitchtheuniton,pressthePowerOnbuttonlocatedonthefrontoftheunit.

5. Displaymessagesafterreplacingbatteries:Afterreplacingdepletedbatteriesacheckbatterymessageisdisplayedonthescreen.PresstheMENUbuttontocontinue.

6. Thescreenwillthendisplayasecondmessagetocheckthebatterycover.Aftercheckingthatthebatterycoverissecureandthatallscrewsaretightened,presstheMENUbutton.

Thebatteryiconshoulddisplaythefullychargedicon.Theunitisreadyforuse.

Screw(6x)

EasyTouchPL4/PSL4ControlSystemWirelessController(rearview)

Batterycover

+

+

+

+

Page 21: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

13

EasyTouch® PL4/PSL4 Control System Outdoor Control Panel Operating ModesTheEasyTouchPL4/PSL4ControlSystemcanruninautomaticmodeormanualmode.Usethe“Mode”buttontoswitchthesystemfrom“Auto”mode(normaloperatingmode)to“Service”formanualoperationandservicepurposes.Beforeoperatingthesystem,familiarizeyourselfwiththeLCDstatusmessagesandoperatingbuttons.

AUTO (Automatic): Thesystemisinnormaloperatingmode.Scheduledprogramswillrunautomatically. HEATER:Displaystheheatsource(Off, Heater, Solar Prf., Solar) asspecifiedintheHeatermenusettings(seepage30).WhentheFilterPump(F)buttonispressedin“Pool”or“Spa”mode,andheatsourceisenabled(HeaterbuttonLEDon).POOL (SPA):IndicatesthattheValves(V)buttonisin“Pool”or“Spa”modeandtheFilterPump(F)buttonhasbeenpressedtoswitchonthefilterpump.Ifthisdisplaylineisblank,itindicatesnospaorpoolfunctionisactive.Forasinglebodysystem,Hi-Temp(Spa)/Lo-Temp(Pool)setsthetemperaturesettings(seepage44)

85° F / 100° F:Displaystheactualspaorpoolwatertemperature(85°F)andthesetpointtemperature(100°F)assetinthe“Heat”menu(seepage30).

AIR:Displaystheactualoutsideairtemperature(70°F)asreadbytheairsensorlocatednearthePowerCenter.

Date and Time:Displaysthesystemdayandtimeasspecifiedinthe“Clock”menusettings(seepage34).

Valves (V) button: Wheninnormaloperatingmode,thesystemisin“Pool”modesothatonlythepoolwateriscirculatedthroughthesystem.PresstheValvesbuttontoenable“Spa”modeandtorotatevalvesandactivatetheFilterpump(FilterPumpLEDon)automaticallysothatonlythespawateriscirculatedthroughthesystem.Notethatthefilterpumpwillswitchoffwhilethepool/spavalvesarerotatingintoposition. “Fill/Spillway”and“Drain”modesareusedonlyin“Service”mode.

MENU / BACK button: Accessthesystemmenu.Alsousedtosaveandexitfromacurrentmenuorsub-menusettings.Whileinmenumode,allsystemcontrolpanelbuttonsaredisabled.Pressthisbuttontwicetorefreshthedisplay.

AUTO HEATERSPA 85°F / 100°F AIR 70°F MON 09:30 AM

Filter Pump button: Forspaoperations,presstheValves (V)buttontorotatevalvesinto“Spa”mode,thenpresstheFilter (F) buttontoactivatethefilterpump.PresstheValvesbuttontotoggleto“Pool”mode.TheHeaterbuttonLEDwillbeonifaheatsourceisenabledintheHeatmenu.

Left and Right Button: Usethesebuttonstolowerandraisethecurrentsetpointwatertemperaturelevel.

Page 22: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

14

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Thefollowingdescribeshowtoadjusttheheattemperatureforthespaandpoolwater,scheduleadailyruntimeforthepool/spafilterpumpandcontrollights.

Heating your Spa (manual control)Heatingthespawaterondemandiseasy,justpresstheSPA buttontoswitchtheheateron.Thecontrolpanelwilldisplaythecurrenttemperaturesetting.Heater”isdisplayedwhentheheaterisactive.Theheaterisactivewhenthesettemperatureishigherthanthewatertemperature.Theheaterwillswitchoffwhenthewatertemperaturerisesabovethesettemperature.Formoreinformationaboutthespamanualheating“MANHEAT”feature,seepage51.PressingtheSpabuttonwillswitchthefilterpumponandrotatethespavalveactuatortoisolateandcirculatethespawaterfromthepoolwater.

Heating your Pool (manual control)Heatingthepoolwaterisnormallypartofthedailyscheduledprogram(seepage32).However,ifyouneedtoadjustthepoolwatertemperature,pressthePool (P) buttontodisplaythecurrenttemperaturesettingsonthePL4/PLS4ControlSystemIndoorControlPanel.“Heater”willbedisplayedonthescreenwhentheheaterisactiveandaheatsourcehasbeenselectedintheHeatmenu.Theheaterisactivewhenthesettemperature,asspecifiedintheHeatmenu,ishigherthanthewatertemperature.Formoreinformationaboutselectingaheatsourceandsettingthepoolwatertemperaturesetting,seepage30.PressingthePoolbuttonwillswitchthefilterpumponandrotatethepoolvalveactuatortoisolateandcirculatethepoolwaterfromthespawater.

Adjusting the water temperature setting Toadjustthesettemperaturesettingforthepoolorspawater,eitherusetheLeft arrow buttontolowerthetemperaturesettingortheRight arrow buttontohigherthetemperaturesetting.

FromtheSchedulesmenuyoucansettheastartandstoptimetoautomaticallyrunpoolandspaequipmentandcontrolunderwaterandbackyardlights.Forexample,thefilterpumprelaycircuitcanbescheduledtorunthedailypoolandspafiltrationataspecifictimeandday(s)oftheweek.Upto4totalprogramschedulesmaybecreatedforallrelaycircuitscombined.Thepoolandspacircuitscanalsobescheduledtoswitchontheheatertoheatthepoolorspawateruptothesetpointtemperatureassetinthe“Heat”menu(seepage30).IfthepoolhasaseparatejetpumporblowercontrolledbyAUX1and/orAUX2,theseneedtobescheduledseparately.Formoreinformation,seepage16.

SPA 0/0 Mode: New

SPA 0 POOL 0 AUX 1 0 AUX 2 0

SPA 1/1 Mode: Schedule 06:00P - 08:00P SMTWTFS

_ _

Quick Start - Pool and Spa Operations (Shared Equipment)

Right button: SelecttheSpacircuit.Thestandardgenericcircuitnamesare:Spa,Pool,Aux1-3,Features1-2.Right button: SelectMode ifthereareexistingprograms.Skipthissteptocreateanewprogram. Up/Down button: SelectNewtocreateanewprogram. Right button: TocreateanewprogramandentertheModesettings. Up/Down button: 1/1indicatesthatthiscircuithasoneprogram.Ifthereareexisting programsassignedtothiscircuit,usethesebuttonstoviewandselecttheexistingprogramsettings. Right button: ToselecttheSchedulesettings. Right button: Movetostartandstoptimesettings. Up/Down and Right buttons: Setstartandstophour(A/P),minutes. TheA(AM)andP(PM)timeissetwhensettingthestartandstophour(6:00PMto8:00PM). Right button: Movetodaysoftheweektoruntheprogram. Right and Up/Down buttons: Bydefaulttheprogramissettorunallthedaysoftheweek.Ifyouwishtoeditwhichdaystoruntheprogram,selectthedayoftheweek,thenpressthe Up/Down buttontoremovethebarfromthetopoftheletter.Abarontopoftheletterindicatesthedayselectedtoruntheprogram.InthisexampleSundayandTuesdayarescheduled.PresstheMenu buttontosavethesettingsandtoreturntotheSchedulesmenuoptions.PresstheMenubuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntotheMainscreen.

Schedules

Schedule start and stop times for equipment

MENU w SCHEDULES w SPA (POOL) Tocreateascheduletoheatthespa:

Page 23: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

15

Quick Start - (Pool and Spa Operations (Shared Equipment) Continued

Heat your spa or poolFirstenabletheheatsource(see“Adjustyourspaheatsettings”below)thenpresstheValves (V)buttontoenable“Spa”mode,andpresstheFilter Pumpbuttontoactivatethefilterpump.Wheninnormaloperatingmode,theValves(V)buttonisin“Pool”modewhichturnsvalvesandactivatesthefilterpumpautomaticallysothatonlythepoolwateriscirculatedthroughthesystem.Pressthebuttontoenable“Spa”modeandactivatetheFilterpumptocirculateonlyspawaterthroughthesystem.Inthemainscreenshownonleft,95°F(35°)isthecurrenttemperatureand100°F (38°C)issetpointtemperature.Bydefault,thesetting“Man Heat’issetto“On”(seepage53)whichallowsthespatobegintoheatwheneveritismanuallyswitchedon.

From the Indoor or wireless control panel (option): FirstenabletheheatsourceintheHeatmenu(see“HeatMenu,”onpage30).PresstheSpabutton(topbutton)toswitchthefilterpumpon,rotatethevalveactuator(toisolatespawaterfrompoolwater),andswitchtheheateron.PressthePoolbuttontoswitchthefilterpumpon,rotatethevalveactuator(toisolatepoolwaterfromspawater),andswitchtheheateron.ForPoolandSpabuttonlocation,seepage5(#6).

Adjust your spa or pool heat settingsFromthe“Heat”menu(MENU > HEAT > POOL TEMP/SRC OR SPA TEMP/SCR)youcanselecttheheatsourceandsetthewatertemperature.Thespaorpoolwaterwillheattothesettingsspecified.TheEasyTouchPL4/PSL4ControlSystemallowsforsolarandconventionalheaters.Thesystemwillusetheheatingsourcethatisselected.Theheatsourceselectionsare:

• OFF -Noheatingeventhoughpumpandothercircuitsmaybeoperating.• HEATER - Gasheateronly.• SOLAR-Solarheatingsystemtobetheonlyheatsource.Inordertodisplay“SolarOnly”asaheat

optioninthe“Heat”menu,youmustfirstenablesolarintheSettings > Solarmenu, (seepage49).

• SOLAR PREF. (Solar Preferred)-Usedifsolarandgasheatingarecombinedandyouwanttousesolarheatingonlywhenitismosteffective.Inordertodisplay“SolarPreferred”asaheatoptioninthe“Heat”menu,youmustfirstenablesolarintheSettings > Solarmenu.

• Heat Pump (UltraTemp):Ifaheatpumpisbeingused(UltraTemp),enabletheUltraTempandheatingsettingfromtheSETTINGS > HEAT PUMP COM > SETTINGSmenuoptions(seepage41).

Tosetthespatemperaturesetpointandselecttheheatsource:

MENU sHEAT

Right button: Selectspatemperatureandheatsource. Up/Down button: Adjustthespawatertemperaturefrom40°Fto104°F (4°Cto40°C) Right or Left button: MovetoHeatsourceoptions. Up/Down: SettheHeatoption:Off, Heater, Solar, orSolar Preferred.

PresstheMenu buttontosavethesettingsandtoreturntotheHeatmenuorpressthebuttonagaintoreturntothemainscreen.Note:Select“POOL Temp/Src”toadjustthepooltemperature.

AUTO HEATERSPA 85°F / 100°F AIR 70°F MON 09:30 AM

POOL Temp/Src SPA Temp/Src

SPA Set Temp: 85° F Heat: Heater

Thefollowingdescribeshowtoadjustheattemperatureforthespaandpoolwater,scheduleadailyruntimefor thepool/spafilterpumpandcontrollightsforsharedequipment.

Page 24: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

16

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Quick Start - Spa and Pool Operations (Shared Equipment) Continued

Schedule start and stop times for equipmentYoucansettimers(schedules)toautomaticallyrunequipmentforpoolfiltrationorturnonorofflights.AnyEasyTouchPL4/PSL4circuitcanbesettoswitchonandoffoneveryoranydayoftheweek.Uptofour(4)totalsystemprogramsmaybecreatedforallcircuitscombined.

Youcanusethe“Schedule”featuretosetthetimeandday(s)whentoswitchthefilterpumponandrotatethepool/spavalvesintothe“Pool”or“Spa”position.Theheaterwillautomaticallyheatthepoolorspawateruptothesetpointtemperatureassetinthe“Heat”menu(seepage30).IfthepoolhasaseparatejetpumporblowercontrolledbyAUX1and/orAUX2,theseneedtobescheduledseparately.Ifyoudon’thaveenoughoryouneedtoconserveauxiliaryrelaycircuits,youcanprogramuptofour“FeatureCircuits.”Ifafeaturecircuitisscheduled,itmustbeturnedonfromthecontrolpanel“FeatureCircuits”menutoallowthescheduletorun(seepage23).

Continue on page 17.

Switch on lights manually and synchronize light colorsFromtheLightsscreenyoucanmanuallyswitchalllightsonoroff,andsynchronizecoloredlights.Uptothree(3)lightscanbecontrolled.Formoreinformationaboutsettinguplights,includingIntelliBrite®LEDlightsandMagicStream®laminars,referto“LightsMenu”onpage25.

MENU sLIGHTS sALL ON

Tomanuallyswitchonalllightsandsynchronizelightcolors:

Pressthe Up/Down button toselect All On orAll Off.UsetheSyncfeaturewithanycombinationofuptothree(3)SAm®,SAL®,IntelliBrite,FIBERworks®lightsandMagicStreamlaminarstosynchronizetheircolorsbeforeswitchingthelightson. PresstheMenubuttontosavethesettingsandtoreturntothemainmenuitemsorpressthebuttonagaintoreturntothemainscreen.

Modes Colors All On All Off

Controlling Lights MENUwSCHEDULESwSPA (POOL)

FromtheLightsscreenyoucanmanuallyswitchalllightsonoroff,configureandsynchronizecoloredlights.FormoreinformationaboutsettingupIntelliBritecoloredshowmodes,fixedcoloredlights,SAmandSAL ColorSwimandColorSetmodes,refertotheLightsMenuonpage23.

Tomanuallyswitchonoroffalllights:

Up/Down button: Select: All Off or All On. PresstheMenubuttonsavethesettingsandtoreturntothemainmenuitemsorpressthebuttonagaintoreturntotheMainscreen.

Modes Colors All OnAll Off

Page 25: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

17

SPA 0/0 Mode: None (New)

SPA 0 POOL 0 AUX 1 0 AUX 2 0

SPA 1/1 Mode: Schedule 08:00A - 05:00P smtwtfs

_ _ _

Quick Start - Spa and Pool Operations (Shared Equipment) Continued

MENUsSCHEDULESwSPA (POOL)

Tocreateascheduleforyourspaorpool:

Right button: SelecttheSpaorPoolcircuit.Youcanalsoselectanyoftheavailablecircuits.Thegenericcircuitnamesare:Spa,Pool,Aux1-3,Feature1-2. Right button: SelectMode ifthereareexistingprograms.Skipthissteptocreateanewprogram. Up/Down button: SelectNewtocreateanewprogram. Right button: Tocreateanewprogramandenterthe“Mode”settings. Up/Down button: 1/1indicatesthatthiscircuithasoneprogram.Ifthereareexistingprogramsassignedtothiscircuit,usethesebuttonstoviewandselecttheexistingprogramsettings. Right button: Toselectthe“Schedule”settings. Right button: Movetostartandstoptimesettings. Up/Down and Right buttons: Setstartandstophour(A/P),minutes. TheA(AM)andP(PM)timeissetwhensettingthestartandstophour. Right button: Movetodaysoftheweektoruntheprogram. Right and Up/Down buttons: Bydefaulttheprogramissettorunallthedaysoftheweek.Ifyouwishtoeditwhichdaystoruntheprogram,selectthedayoftheweek,thenpresstheUp/Down buttontoremovethebarfromthetopoftheletter.Abarontopoftheletterindicatesthedayselectedtoruntheprogram. PresstheMenu buttontosavethesettingsandtoreturntotheSchedulesmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Page 26: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

18

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Setting the Egg Timer Feature (One time schedule)The“EggTimer”featureletsyoumanuallyswitchonequipmentandprogramthesystemtoautomaticallyswitchoffafteraspecifiedtime.Youcansetthistimerfeatureforotherequipmentsuchaslighting,spa,orspajets.Equipmentcanbesettobeonforoneminuteor24hours.TheEggTimerprogramisfactorysettoswitchoffafter12hours.Youalsohavetheoptiontousethe“Don’tStop”featuretorunacircuitcontinuouslyuntilmanuallyswitchedoff.

Pleasenotethatintheeventofapowerfailure,theEggTimerfeaturewillnotswitchthecircuitbackon.Usethe“Service” modebuttontoturntheequipmentbackonmanually.Referto“Modebutton,”page5fordetails.

Note: When running the filter pump continuously during a new pool start up, it is recommended to use the “Service” mode, which will automatically restart the filter pump in the event of a power failure.

TosettheEggTimerfeature:

MENUsSCHEDULESwSPA (POOL)

Right button: SelecttheSpaorPoolcircuit.Youcanalsoselectanyoftheavailablecircuits.Thegenericcircuitnamesare:Spa,Pool,Aux1-3,andFeature1-2.

Right button: SelectMode ifthereareexistingprograms.Skipthissteptocreateanewprogram.

Up/Down button: SelectNewtocreateanewprogram.

Right button: Tocreateanewprogramandenterthe“Mode”settings.

Up/Down button: 1/1indicatesthatthiscircuithasoneprogram.Youcan createatotalof4programs.Ifthereareexistingprogramsassignedtothiscircuit,usethesebuttonstoviewandselecttheexistingprogramsettings.

Right button: Toselectthe“EggTimer”settings.

Right button: Movetothetimesettings.

Up/Down and Right buttons: Setthehourandminutesfortheprogramtorun.Thecountdowntimecanbesetfrom00:01to23:59andDon’tStop.The“Don’tStop”featureallowsthecircuittoruncontinuouslyuntilmanuallyswitchedoff.

PresstheMenu buttontosavethesettingsandtoreturntotheSchedulesmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

SPA 1/1 Mode: Egg Timer Time: 05:00

SPA 0/0 Mode: None (New)

SPA 0 POOL 0 AUX 1 0 AUX 2 0

Page 27: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

19

Section2 Setting up the EasyTouch® PL4/PSL4 Control System

Setting up the EasyTouch PL4/PSL4 Control System for the First Time

UsethefollowingstepsifyouaresettinguptheEasyTouchPL4/PSL4ControlSystemforthefirsttime.Note: The following setup steps assume that the EasyTouch PL4/PSL4 Control System Power Center is installed at the equipment pad and ready for operation. For more information see the EasyTouch PL4/PSL4 Control System Power Center installation instructions (P/N 520583). TherecommendedfirsttimeinstallationstepsfortheEasyTouchPL4/PSL4ControlSystemare:

1. Set the system date and time (page 34)Setthecurrentdateandtime.

2. Assign circuit names (pages 42)Assignthegenericdefaultcircuitnamesforoutputauxiliaryequipment.Rename(ifnecessary)andassigncircuitnamestotheauxiliary(AUX1,AUX2,AUX3)connections.Notethefactorysetauxiliarynamescorrespondtotheplug-inlocationoftherelayonthemotherboard.Youcanassigncircuitnamesfromtheavailableofcircuitnames.Therearenearly100circuitnamesavailable(seepage43forthecompletelist).

3. Create custom names for auxiliary circuits (page 46)Ifyoucannotfindacircuitnamethatfitsyourapplicationyoucancreateupto10additionalcustomizednamesthatcanbecreatedbeforeassigningcircuitnames.

4. Assign a “Circuit Function” to a “Circuit Name” (Page 44)Assign“CircuitFunctions”(1-7)totheauxiliarycircuitnamesyoucreatedinStep3above.FromtheCircuitFunction menu,youcanassignspeciallogictoacircuitbyselectingoneoftheavailablecircuitfunctions.ForthecompletelistofpresetCircuitFunctions.Ifanauxiliarycircuit(AUX)isassignedGENERIC(simpleON/OFFwhenthebuttonispushed)thennothingneedstobedone.

5. Create “Feature Circuits” to conserve relays (page 23)IfyouneedtoconservephysicalauxiliaryPowerCenterrelays,therearetwo(2)FeatureCircuitsavailablethatyoucanassigntocircuitfunctions.FeatureCircuitsaremanuallyturnedonorofffromthecontrolpanel“FeatureCircuits”menu.

6. Configure valve actuators (controlled by AUX circuit) (page 46)TheEasyTouchPL4/PSL4ControlSystemcandriveoneauxiliaryvalveactuatorsforapplicationssuchassolarheatingandwaterfeatures.AssignwhichcircuitsthatwillactivatevalvesAandB.AuxiliaryvalveactuatorscanbecontrolledbyanyAUXcircuit.ValveAisautomaticallyassignedtosolarif“Solar”isenabledinthe“Solar”menu.Tip:Usea“FeatureCircuit”tocontrolavalveactuator(seepage23).

7. Set up optional equipment, solar, two-speed pump (page 47)Setupadditionalequipmentsuchassolar,2-speedpump,andoptionalequipmentifrequired.SetupthecontrolpaneltooperatewiththeoptionalIntelliChlor® SaltChlorineGenerator(seepage38andIntelliChem® Controller(seepage39).Toconfigurethesystemforspecialequipment:

• Issolarheatingavailable?Issolarbeingusedforaheatpump?• Whatcircuitswillturn2-SpeedpumpstoHighSpeed?• Isthereaheatpump(UltraTemp®HeatPump)beingused?• IsthereanIntelliChlor®SCGinstalled?• IsthereanIntelliChem®Controllerinstalled?• Cool-downcyclefortheheater-Letsyousetcircuitsthatswitchthefilterpumptohighspeed.• Doyouwanttodelayturningoffthefilterpumpfor10minuteswhentheheateristurnedoff?• DoyouwantthespatoheatwhenevertheSpabuttonispressed?

Page 28: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

20

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

8. Configure the heater system options (page 30)Setthetypeofheatsourcebeingused(Heater,Solar,SolarPreferred).Enableheatpump(UltraTemp®HeatPump)forheating/coolingifinstalled.

9. Configure the iS4 Spa-Side Remote (page 44)AssigncircuitstotheiS4Remotebuttons.Onceyouhavecheckedthatallbuttonsoperateproperly,placelabelsonremotebuttons.

10. Set the delays feature (page 48)Enabletheonetime“delay”featurefortheheater,2-speedpump,andautomaticpoolcleaner.

11. Schedule on/off times for circuit (page 32)Settimesforautomaticcircuitactivation.Uptofour(4)totalprogramscanbecreatedforallcircuitscombined.Onecircuitcanhaveuptoamaximumoffour(4)programs(4/4),orprogramscanbeusedbyseparatecircuits.Allusercreatedprogramsareactiveallthetime;socheckthattherearenotconflictingautomatedtimes.

EasyTouch® PL4/PSL4 Control System Menus

MAIN SCREEN

LIGHTS

HEAT POOL TEMP/SRC TEMP (40° F - 104° F) OR (4° C - 41° C)HEAT (OFF/HEATER/SOLAR/SOLAR PRF) - SOLAR/SOLAR PRF MUST BE ENABLED IN "SOLAR" MENU TO DISPLAY.

SPA TEMP/SRC TEMP (40° F - 104° F) OR (4° C - 41° C)HEAT (OFF/HEATER/SOLAR/SOLAR PRF) - "SOLAR/SOLAR PRF" MUST BE ENABLED IN "SOLAR" MENU TO DISPLAY.

DELAY CANCEL

MODE: SCHEDULE08:00A -- 05:00P (12:00 AM - 11:59 PM -12 HOURS)S M T W T F S (DAYS OF THE WEEK)

SCHEDULES SPA 0

AUX 2 0

AUX 3 0 MODE: EGG TIMER TIME: 12:00 (00:00 - 23:59) / DON'T STOP

SETTINGS

INTELLICHLOR INTELLICHLOR 1/2 - ENABLE (YES/NO), POOL MODE: 0 - 100 % (50% default) SPA MODE: 0% (2% default)INTELLICHLOR 2/2 - SUPER CHLR (ON/OFF), RUN HOURS (0 -72) (OPTIONAL)

CIRCUIT NAMES CIRCUIT NAMES (1/7) - [SPA, POOL, AUX1, AUX2, AUX3, FEATURE 1-2]

CIRCUIT FUNC.CIRCUIT: (SPA [MASTER SPA], POOL [MASTER POOL], AUX 1-3, FEATURE 1-2, AUX EXTRA -

FREEZE: NO/YES

CUSTOM NAMES CSTM NAME 1/7 (ASSIGN UP TO 100 CUSTOM NAMES) [USERNAME-01...100] (UP TO 11 ALPHANUMERIC CHARACTERS)

2-SPEED PUMPCIRCUIT (NONE, SPA, POOL, AUX1, AUX2,AUX3, FEATURE 1-2, SOLAR, HEATER, POOL HEATER, SPA HEATER, FREEZE) 2-SPEED PMP 1/4 (ASSIGN UP TO 4 CIRCUITS)

SOLAR

DELAYS COOL DOWN (YES/NO) - VALVES (YES/NO)

SOLAR 1/2 - ENABLE (YES/NO) - HEAT PUMP (YES/NO) - SOLAR 2/3 - FREEZE, SOLAR 3/3 (TEMPREATURE DIFFERENCE) - START (3°-9° (6° default)) - RUN (2°-5° (3° default))

VALVES

CLOCK

F° / C°

iS4

FAHRENHEIT / CELCIUS

CIRCUIT - (NONE, SPA, POOL, AUX 1 - 3, FEATURE 1-2) ASSIGN CIRCUITS 1/4

DATE & TIME 1/2 - (MONTH/DAY/YEAR) - (DAY/HOUR/MINUTES/AM/PM) DATE & TIMER 2/2 - DAYLIGHT SAVING: (AUTO/MANUAL)CLOCK ADJUST 00:00 (0 TO 300) - (-300 TO -5) IN 5 SCEOND INCREMENTS

(DELAYED CANCELLED) PRESS RIGHT BUTTON TO ACTIVATE

A: [NONE, SPA, POOL, AUX1, AUX2, AUX3, FEATURE 1-2, HEATER] B: [NONE, SPA, POOL, AUX 1, AUX2, AUX3, FEATURE 1-2, HEATER]

POOL 0

AUX 1 0

MSTR CLEANER, LIGHT, SAM LIGHT, SAL LIGHT, PHOTON GENERATOR, COLOR WHEEL,

MODE: NEW / DELETE / NONE

HI-TEMP (SPA) / LO-TEMP (POOL) FOR SINGLE BODY SYSTEM (SEE SETTINGS MENU: CIRCUIT NAMES)

DIAGNOSTICS SOFTWARE REV (REVISION LEVEL FOR THE OUTDOOR AND INDOOR CONTROL PANEL)BOOTLOADER REV (REVISION LEVEL FOR THE OUTDOOR AND INDOOR CONTROL PANEL)SELF TEST (STATUS: TESTING (FOLLOW ON-SCREEN PROMPTS TO TEST LCD AND BUTTONS) - CODE: 0 -

WATER TEMP (FAHRENHEIT/CELCIUS - STATUS DISPLAY ONLY)SOLAR TEMP (FAHRENHEIT/CELCIUS - STATUS DISPLAY ONLY) - (DISPLAYS IF SOLAR IS ENABLED IN HEAT MENU)AIR TEMP (FAHRENHEIT/CELCIUS - STATUS DISPLAY ONLY)DISP OP CODES - DISPLAY? NO/YES (DISPLAYS TRANSMIT/RECEIVE PACKETS NUMBERS ON SCREEN)

SPA SIDE [OFF/ON] ENABLE/DISABLE IS4 SPA-SIDE REMOTE

CIR NAMES [ON/OFF] VIEW DEFAULT CIRCUIT NAMES BEFORE MODIFICATION.

CHLORINATOR SALT LEVEL: DISPLAYS CURRENT SALT LEVEL (XXXX) PPMSTATUS: OK - NO ERRORS (SUPER CHLORINATE, COM LINK ERROR, CHECK FLOW / PCB,

RESET SYSTEM (REINITIALIZE INDOOR CONTROL PANEL - USE RIGHT BUTTON)FLASH UPDATE (USED FOR FIRMWARE UPDATES VIA PC - PRESS MENU TO ABORT)

INTELLIFLO(OPTIONAL)

FEATURE 1-2 0

MODES [6 LIGHT SHOWS, HOLD, RECALL, COLOR SWIM, COLOR SET]COLORS [5 FIXED COLORS, HOLD, RECALL, COLOR SWIM, COLOR SET]ALL ON (SWITCH ALL LIGHTS ON)ALL OFF (SWITCH ALL LIGHTS OFF)SYNC (SYNCHRONIZE COLORED LIGHTS)MAGICSTREAM [TOGGLE THUMPER, HOLD, RESET, CHANGE MODE]CONFIG (SETUP EIGHT LIGHT POSITIONS)

FEATURE CIR FEATURE 1-2 [OFF]

FEATURE 1 - 2

MANUALLY TURN A FEATURE CIRCUIT ON/OFF.USE FEATURE CIRCUITS TO CONTROL PUMP SPEEDS AND VALVES.

PUMP #1 - PUMP TYPE [VS, VSF, NONE]

HEAT PUMP COM SETTINGS: ENABLE, DISABLE (NO/YES) - [HEATING, COOLING] - STATUS(OPTIONAL)

QUICK TOUCH II ASSIGN QT4 II 1/4 (ASSIGN UP TO 4 CIRCUITS)CIRCUIT - (NONE, SPA, POOL, AUX 1 - 3, FEATURE 1-2)

ERASE EEPROM ERASE ALL (YES /NO) - ARE YOU SURE? (YES/NO)

CALIBRATION WATER (FAHRENHEIT/CELCIUS) - AIR (FAHRENHEIT/CELCIUS) - SOLAR (FAHRENHEIT/CELCIUS) -

SWITCH MANUAL HEAT ON OR OFF WHEN SPA IS MANUALLY SWITCHED ON (USE RIGHT BUTTON SELECT ON/OFF)MAN HEAT [OFF/ON]

SET PASSWORD SET PASSWORD: XXXX 4 DIGITS - ENABLE / DISABLE [NO/YES]

WIRELESS ADDR SET AN ADDRESS FOR EASYTOUCH WIRELESS CONTROL PANEL

INTELLICHEM PH/OPR Values (pH VAL, SET - OPR VAL, SET) - Status (pH/OPR level) - Saturation Index (CH,TDS,TA,SI)(OPTIONAL)

WIRELESS ADDR SET AN ADDRESS FOR EASYTOUCH WIRELESS CONTROL PANEL

BACKLIGHT ON TIME: 5 S, 15 S, 30 S, 60 S, 5 M, OFF [BRIGHTNESS: LOW, MED HI]

POWER SAVE IDLE TIME: 15 S, 30 S, 60 S, 5 ME

FILTERING, PRIMING, BACKWASH, VACUUM, STATUS

FUNCTIONS: GENERIC, MASTER SPA, MASTER POOL,

SPILLWAY, FLOOR CLEANER, INTELLIBRITE, MAGICSTREAM,

SOLAR MUST BE ENABLED IN "HEAT" MENU TO DISPLAY

SEE "TROUBLESHOOTING" SECTION FOR ERROR CODES)

LOW SALT, VERY LOW SALT, HIGH CURRENT, CLEAN CELL!!, LOW VOLTAGE)

WIRELESS CONTROL PANEL ONLY

Continue on next page.

A

Page 29: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

21

EasyTouch® PL4/PSL4 Control System Menus (Continued)

MAIN SCREEN

LIGHTS

HEAT POOL TEMP/SRC TEMP (40° F - 104° F) OR (4° C - 41° C)HEAT (OFF/HEATER/SOLAR/SOLAR PRF) - SOLAR/SOLAR PRF MUST BE ENABLED IN "SOLAR" MENU TO DISPLAY.

SPA TEMP/SRC TEMP (40° F - 104° F) OR (4° C - 41° C)HEAT (OFF/HEATER/SOLAR/SOLAR PRF) - "SOLAR/SOLAR PRF" MUST BE ENABLED IN "SOLAR" MENU TO DISPLAY.

DELAY CANCEL

MODE: SCHEDULE08:00A -- 05:00P (12:00 AM - 11:59 PM -12 HOURS)S M T W T F S (DAYS OF THE WEEK)

SCHEDULES SPA 0

AUX 2 0

AUX 3 0 MODE: EGG TIMER TIME: 12:00 (00:00 - 23:59) / DON'T STOP

SETTINGS

INTELLICHLOR INTELLICHLOR 1/2 - ENABLE (YES/NO), POOL MODE: 0 - 100 % (50% default) SPA MODE: 0% (2% default)INTELLICHLOR 2/2 - SUPER CHLR (ON/OFF), RUN HOURS (0 -72) (OPTIONAL)

CIRCUIT NAMES CIRCUIT NAMES (1/7) - [SPA, POOL, AUX1, AUX2, AUX3, FEATURE 1-2]

CIRCUIT FUNC.CIRCUIT: (SPA [MASTER SPA], POOL [MASTER POOL], AUX 1-3, FEATURE 1-2, AUX EXTRA -

FREEZE: NO/YES

CUSTOM NAMES CSTM NAME 1/7 (ASSIGN UP TO 100 CUSTOM NAMES) [USERNAME-01...100] (UP TO 11 ALPHANUMERIC CHARACTERS)

2-SPEED PUMPCIRCUIT (NONE, SPA, POOL, AUX1, AUX2,AUX3, FEATURE 1-2, SOLAR, HEATER, POOL HEATER, SPA HEATER, FREEZE) 2-SPEED PMP 1/4 (ASSIGN UP TO 4 CIRCUITS)

SOLAR

DELAYS COOL DOWN (YES/NO) - VALVES (YES/NO)

SOLAR 1/2 - ENABLE (YES/NO) - HEAT PUMP (YES/NO) - SOLAR 2/3 - FREEZE, SOLAR 3/3 (TEMPREATURE DIFFERENCE) - START (3°-9° (6° default)) - RUN (2°-5° (3° default))

VALVES

CLOCK

F° / C°

iS4

FAHRENHEIT / CELCIUS

CIRCUIT - (NONE, SPA, POOL, AUX 1 - 3, FEATURE 1-2) ASSIGN CIRCUITS 1/4

DATE & TIME 1/2 - (MONTH/DAY/YEAR) - (DAY/HOUR/MINUTES/AM/PM) DATE & TIMER 2/2 - DAYLIGHT SAVING: (AUTO/MANUAL)CLOCK ADJUST 00:00 (0 TO 300) - (-300 TO -5) IN 5 SCEOND INCREMENTS

(DELAYED CANCELLED) PRESS RIGHT BUTTON TO ACTIVATE

A: [NONE, SPA, POOL, AUX1, AUX2, AUX3, FEATURE 1-2, HEATER] B: [NONE, SPA, POOL, AUX 1, AUX2, AUX3, FEATURE 1-2, HEATER]

POOL 0

AUX 1 0

MSTR CLEANER, LIGHT, SAM LIGHT, SAL LIGHT, PHOTON GENERATOR, COLOR WHEEL,

MODE: NEW / DELETE / NONE

HI-TEMP (SPA) / LO-TEMP (POOL) FOR SINGLE BODY SYSTEM (SEE SETTINGS MENU: CIRCUIT NAMES)

DIAGNOSTICS SOFTWARE REV (REVISION LEVEL FOR THE OUTDOOR AND INDOOR CONTROL PANEL)BOOTLOADER REV (REVISION LEVEL FOR THE OUTDOOR AND INDOOR CONTROL PANEL)SELF TEST (STATUS: TESTING (FOLLOW ON-SCREEN PROMPTS TO TEST LCD AND BUTTONS) - CODE: 0 -

WATER TEMP (FAHRENHEIT/CELCIUS - STATUS DISPLAY ONLY)SOLAR TEMP (FAHRENHEIT/CELCIUS - STATUS DISPLAY ONLY) - (DISPLAYS IF SOLAR IS ENABLED IN HEAT MENU)AIR TEMP (FAHRENHEIT/CELCIUS - STATUS DISPLAY ONLY)DISP OP CODES - DISPLAY? NO/YES (DISPLAYS TRANSMIT/RECEIVE PACKETS NUMBERS ON SCREEN)

SPA SIDE [OFF/ON] ENABLE/DISABLE IS4 SPA-SIDE REMOTE

CIR NAMES [ON/OFF] VIEW DEFAULT CIRCUIT NAMES BEFORE MODIFICATION.

CHLORINATOR SALT LEVEL: DISPLAYS CURRENT SALT LEVEL (XXXX) PPMSTATUS: OK - NO ERRORS (SUPER CHLORINATE, COM LINK ERROR, CHECK FLOW / PCB,

RESET SYSTEM (REINITIALIZE INDOOR CONTROL PANEL - USE RIGHT BUTTON)FLASH UPDATE (USED FOR FIRMWARE UPDATES VIA PC - PRESS MENU TO ABORT)

INTELLIFLO(OPTIONAL)

FEATURE 1-2 0

MODES [6 LIGHT SHOWS, HOLD, RECALL, COLOR SWIM, COLOR SET]COLORS [5 FIXED COLORS, HOLD, RECALL, COLOR SWIM, COLOR SET]ALL ON (SWITCH ALL LIGHTS ON)ALL OFF (SWITCH ALL LIGHTS OFF)SYNC (SYNCHRONIZE COLORED LIGHTS)MAGICSTREAM [TOGGLE THUMPER, HOLD, RESET, CHANGE MODE]CONFIG (SETUP EIGHT LIGHT POSITIONS)

FEATURE CIR FEATURE 1-2 [OFF]

FEATURE 1 - 2

MANUALLY TURN A FEATURE CIRCUIT ON/OFF.USE FEATURE CIRCUITS TO CONTROL PUMP SPEEDS AND VALVES.

PUMP #1 - PUMP TYPE [VS, VSF, NONE]

HEAT PUMP COM SETTINGS: ENABLE, DISABLE (NO/YES) - [HEATING, COOLING] - STATUS(OPTIONAL)

QUICK TOUCH II ASSIGN QT4 II 1/4 (ASSIGN UP TO 4 CIRCUITS)CIRCUIT - (NONE, SPA, POOL, AUX 1 - 3, FEATURE 1-2)

ERASE EEPROM ERASE ALL (YES /NO) - ARE YOU SURE? (YES/NO)

CALIBRATION WATER (FAHRENHEIT/CELCIUS) - AIR (FAHRENHEIT/CELCIUS) - SOLAR (FAHRENHEIT/CELCIUS) -

SWITCH MANUAL HEAT ON OR OFF WHEN SPA IS MANUALLY SWITCHED ON (USE RIGHT BUTTON SELECT ON/OFF)MAN HEAT [OFF/ON]

SET PASSWORD SET PASSWORD: XXXX 4 DIGITS - ENABLE / DISABLE [NO/YES]

WIRELESS ADDR SET AN ADDRESS FOR EASYTOUCH WIRELESS CONTROL PANEL

INTELLICHEM PH/OPR Values (pH VAL, SET - OPR VAL, SET) - Status (pH/OPR level) - Saturation Index (CH,TDS,TA,SI)(OPTIONAL)

WIRELESS ADDR SET AN ADDRESS FOR EASYTOUCH WIRELESS CONTROL PANEL

BACKLIGHT ON TIME: 5 S, 15 S, 30 S, 60 S, 5 M, OFF [BRIGHTNESS: LOW, MED HI]

POWER SAVE IDLE TIME: 15 S, 30 S, 60 S, 5 ME

FILTERING, PRIMING, BACKWASH, VACUUM, STATUS

FUNCTIONS: GENERIC, MASTER SPA, MASTER POOL,

SPILLWAY, FLOOR CLEANER, INTELLIBRITE, MAGICSTREAM,

SOLAR MUST BE ENABLED IN "HEAT" MENU TO DISPLAY

SEE "TROUBLESHOOTING" SECTION FOR ERROR CODES)

LOW SALT, VERY LOW SALT, HIGH CURRENT, CLEAN CELL!!, LOW VOLTAGE)

WIRELESS CONTROL PANEL ONLY

A

Page 30: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

22

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

EasyTouch® PL4/PSL4 Control Systems MenusFromtheEasyTouchPL4/PSL4ControlSystemscontrolpanelmenusyoucanscheduleeverydaypool/spa,heating,filtrationandcleaning.Lightsandlaminarscanalsobescheduledtoswitchonandoffatspecifictimes.The“Settings”and“Schedule”menusaretypicallyusedmostoftenfordailyspaandpooloperations.The“Settings”menuisusedbythepoolinstallertosetupinstalledequipmentwhichisconnectedtoeachoutputrelay(filterpump,auxiliaryrelays,heater,valves,lights,etc.).ForEasyTouchPL4/PSL4ControlSystemsequipmentinstallationinstructions,seetheEasyTouchPL4/PSL4ControlSystemsInstallationGuide(P/N520584).

Main ScreenTheEasyTouchPL4/PSL4ControlSystemsmainscreendisplaysthecurrentmodeofoperation (AUTO/SERVICE/TIMEOUT),heatsourcebeingused,spa(orpool)actualwatertemperature(95°F),currentheatersetpointtemperature(100°F)andthecurrentambientairtemperature(airsensor).DegreeunitscanbedisplayedineitherFahrenheit(default)orCelsius(seepage49).Iftheseconddisplaylineisblankandtheheatsourceisnotdisplayed,thereisnospaorpoolfunctioncurrentlyactive.Themainscreenisautomaticallydisplayedifthereisnocontrolpanelmenuactivityforfiveminutes.IfthereisanIntelliChlor®SaltChlorineGenerator(SCG)beingused,poolandspasanitizersettings,andsaltlevelscanbeviewedintheDiagnostics,“Chlorinator,”settings(seepage38).

Main Screen DescriptionAUTO:Thecontrolsystemisinnormal(automatic)operatingmode.Forinformationabout“Service”and

“Timeout”operatingmodes,seepage4.HEATER:Theselectedheatsourceasselectedinthe“Heat”menu(seepage30).Theheatoptionsare:• OFF -Noheatingeventhoughpumpandothercircuitsmaybeoperating.• HEATER - Gasheateronly.• SOLAR ONLY-Solarheatingsystemtobetheonlyheatsource.Inordertodisplay“SolarPref.”on

themainscreen,youmustfirstenablesolarinthe“Solar”menu(seepage30).• SOLAR PREF.-(SolarPreferred)-Forwhensolarandgasheatingarecombined,andyouwantto

usesolarheatingonlywhenitismosteffective.Inordertodisplay“SolarPref.”onthemainscreen,youmustfirstenablesolarinthe“Solar”menu.

SPA: “SPA”isdisplayedaftertheValves (V) buttonispressedtosetin“spa”modethentheFilter (F)buttonispressedtoswitchthefilterpumpon,rotatethevalveactuator(toisolatespawaterfrompoolwater),andswitchtheheateron(ifenabledinthe“Heat”menu).PressingtheValves (V)buttonalternatesbetween“Pool”and“Spa”mode.Thetemperatureunitdisplayedontheleftsideistheactualwatertemperature(95°F)andthesetpointtemperature(100°F)assetinthe“Heat”menuisdisplayedontherightside.Ifthisdisplaylineisblank,itindicatesnospaorpoolfunctioniscurrentlyactive.ForHi-Tempcontrols(singlebodysystem),seepage30.

POOL: “POOL”isdisplayedaftertheFilter (F)buttonispressedtoswitchthefilterpumpon,rotatethevalveactuatortoisolatethepoolwaterfromthespawater,andswitchtheheateron(ifenabledinthe“Heat”menu).PressingtheValves (V)buttonalternatesbetween“Pool”and“Spa”mode.Thetemperatureunitdisplayedontheleftsideistheactualwatertemperature(95°F)andthesetpointtemperature(100°F)assetinthe“Heat”menuisdisplayedontherightside.Ifthisdisplaylineisblank,itindicatesnospaorpoolfunctioniscurrentlyactive.ForLo-Tempcontrols(singlebodysystem),seepage30.

AIR:Displaystheactualoutsideambientairtemperature(70°F)asrecordedbytheairsensorlocatedneartheEasyTouchPL4/PSL4ControlSystemsPowerCenter.

DAY and TIME: Thecurrentsystemdayandtime(AM/PM).Seethe“Clock”menutosetthesystemdayandtime(page34).

AUTO HEATERSPA 85°F / 100°F AIR 70°F MON 09:30 AM

AUTO AIR 70°F MON 11:30 AM

AUTO HEATERPOOL 85°F / 95°F AIR 70°F MON 10:30 AM

Page 31: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

23

Feature Circuits MenuTherearetwoFeatureCircuitsthatcanbeusedtocontrolIntelliFlo®Pumpspeedsorvalvesactuatorsforaspaspillway.Unlikeanauxiliaryrelaycircuit,a“Feature”circuitdoesnotconnectdirectlytoarelay.“Feature”areturnedonandofffromthecontrolpanel“Feature”circuitmenu.

Feature Circuits

MENU wF. CIRCUITS

ToswitchafeaturecircuitONorOFF:

Right button: SelectthefeaturecircuittoturnONorOFF.. Up/Down buttons: Chooseassignedfeaturecircuit:FEATURE1-2. Right button: SwitchtheselectedfeaturecircuitsONorOFF. Whenfinished,presstheMenubuttontwicetoreturntothemainscreen.

Lights MenuFromtheLightsscreenyoucanmanuallyswitchalllightsonoroff,andsynchronizecoloredlights.Uptothree(3)lightscanbeindependentlycontrolledfromtheLightsscreen.Eachlightrequiresaseparateauxiliaryrelaycircuit.Uptothree(3)lightscanbeassignedoneachauxiliarycircuit.AcircuitnamemustbeassignedtotheAUXrelaycircuitswhichcontrolsthelight.VerifythatIntelliBrite®,SAm®,SAL®,and/orFIBERworks® havebeenselectedinCircuitFunction.IfFIBERworkslightingisbeingused,italsohastobesetupasaPhotonGenerator®lightsource(PHOTONGENERATOR)forthecircuitcontrollingthelightbulb,andCOLORWHEELforthecircuitcontrollingthecolorwheel.Formoreinformationaboutsettinguplights,see“SettingsMenu:CircuitFunction,”onpage44.

MENUsLIGHTSwLIGHTS

The Color Swim and Color Set Lighting Features

Modes Colors All On All Off

Hold Recall Color Swim Color Set

TheColorSwimandColorSetlightingfeaturesisselectedfromtheLIGHTS > MODES and(COLORS)menu.Atleasttwo(2)IntelliBrite®,SAm®,SAL®,and/orFIBERworks® lightingsystemsarerequiredtousethelightingfeatures.

• ColorSwim-SelecttheColorSwimfeatureintheMODESandCOLORSmenustostartlightstotransitionthroughcolorsinsequencetogivetheappearanceofcolorsdancingthroughthewater.YoucanadjustthedelayofeachlighttomakethecolorsmoveatdifferentspeedsusingtheLIGHTS>CONFIGoption.Thislightingfeaturerequiresaseparaterelayforeachlight.ToswitchofftheColorSwimfeature,selecttheAUXbuttonassignedtothelightcircuitorselectALLOFFintheLightsmenu.

• ColorSet-SelecttheColorSetfeatureintheMODESandCOLORSmenustoswitchthelightonusingspecificcolorasselectedintheCOLORSmenu.Thisfeaturerequiresaseparaterelayforeachlight.ToswitchofftheColorSwimfeature,selecttheAUXbuttonassignedtothelightcircuitorselectALLOFFintheLightsmenu.

• Configure- Select“Configure”tosetupthepositionsofthelightsthepool.Uptoeight(8)lightscanbeassignedaposition.Formoreinformationseepage27.

All On All Off Sync Configure

1- [NONE ] 2- [NONE ] 3- [NONE ]

1- [AUX 1 ] 2- [LT.GREEN ] 3- [1ST POSITION ] 4. [DELAY 5 SECS]

F. CircuitsLights Heat Delay Cancel

FEATURE 1 [ON] FEATURE 2 [OFF]

Page 32: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

24

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Setting up LightsThefollowingsectiondescribeshowtoassignalightcircuitnameandfunctiontocontrolIntelliBrite®,SAm®,SAL®, and/orFIBERworks® lights.

Assign the Light Circuit Name and Function

Thefirststepinsettingupalightcircuitistoassignanametotherelaycircuit(example;AUX3,as“PoolLight”),thenassignthename“PoolLight”circuitintheCircuitFunc.menuasa“light”circuit(IntelliBrite,SAM,SAL..).Thelightcircuitfunctionsare:Light, SAM, SAL, Photon Generator, Color Wheel, Spillway, MagicStream and IntelliBrite (seepage45).Afterassigningthecircuitnameandfunction,thelightcircuitname“PoolLight”canbesetupintheCONFIGmenuforlightposition,coloretc.

ToassignaCIRCUITNAME:

MENUsSETTINGSsCIRCUIT NAMESw

Up/Down buttons: Selectthecircuitnumber1/7.PresstheUp buttontwotimestoselectAUX1tochoosethiscircuitforalightcircuitOn/Offbutton.Thegenericcircuitsnamesare:Spa,Pool,Aux1-3,FEATURE1-2(Ft.1-2).Thecircuitnumber(1/7)correspondstoitsassignedcircuitname. Right button: Selectthesystempresetcircuitnamesanduserdefinedcustomcircuitnames. Up/Down buttons: Scrollthroughthelistofpresetnames(seepage45foracompletelistofcircuitnames).Selectanamethatdescribeswherethelightislocatedorthatsuitsthefunction,suchas“PoolLight.”AUX1hasnowbeenassignedthecircuitname“PoolLight.”Ifyoucannotfindanametomatchyourcircuit,youcancreateyourowncustomname(seepage43).Repeatthisstepforallthecircuitbuttonsthatyouwishtoassignnamesto. PresstheMenubuttontoreturntotheSettingsmenu.PresstheDownbuttontoandselect“CircuitFunc.”PresstheRight button toaccess theCircuitFunc.menu.

Up/Down buttons: Selectthealreadyassignedcircuitname“PoolLight.” Right button: View“CircuitFunctions”toassigntolightcircuit“PoolLight.” Up/Down buttons: Selectthetypeoflightcircuitfunctiontouse.Thecircuitfunctionnamesare:LIGHT,SAMLIGHT,SALLIGHT,PHOTONGEN,COLOR

Note:Tousethe“ColorSwim”or“ColorSet”feature,selectIntelliBrite,SAM,SAL,PhotonGeneratororColorWheel.Select“MagicStream”forMagicStreamlaminars.

PresstheMenubuttonthreetimestoreturntothemainscreen.WHEEL,VALVE,SPILLWAY,FLOORCLEANER,INITELLIBRITE,MAGICSTREAM,GENERIC,andMSTRCLEANER.Foracompletelistofpresetcircuitfunctions,see“PresetCircuitFunctions”onpage45.

ToassignaCIRCUITFUNCTION:

MENUsSETTINGSsCIRCUIT FUNC.w

PresstheMenubuttontoreturntotheSettingsmenu.PresstheDownbuttontoandselect“CircuitFunc.”PresstheRight button toaccess theCircuit Func. menu.

Up/Down buttons: Selectthealreadyassignedcircuitname“PoolLight.” Right button: View“CircuitFunctions”toassigntolightcircuit“PoolLight.” Up/Down buttons: Selectthetypeoflightcircuitfunctiontouse.Thecircuitfunctionnamesare:LIGHT,SAMLIGHT,SALLIGHT,PHOTONGEN,COLORWHEEL,VALVE,SPILLWAY,FLOORCLEANER,INITELLIBRITE,MAGICSTREAM,GENERIC,andMSTRCLEANER.Foracompletelistofpresetcircuitfunctions,see“PresetCircuitFunctions”onpage45.

Note:Tousethe“ColorSwim”or“ColorSet”feature,selectIntelliBrite,SAM,SAL,PhotonGeneratororColorWheel.Select“MagicStream”forMagicStreamlaminars.

PresstheMenubuttonthreetimestoreturntothemainscreen.

Circuit Names Circuit #: 1/7 Circuit : AUX 1 [POOL LIGHT ]

IntelliFlo IntelliChlor Circuit Names Circuit Func.

Circuit / Func. : [POOL LIGHT ] [INTELLIBRITE ] Freeze: No

Page 33: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

25

Setting up Lights (Continued)FromtheLightsscreenyoucanmanuallyswitchalllightsonoroff,synchronizecoloredlights,andactivatecolorlightshows.Uptothree(3)lightcircuitscanbeconfiguredfromthe“Config”lightmenu.Eachlightmusthaveitsownrelayandseparatecircuit.

Setting up IntelliBrite Light CircuitsBeforeconfiguringthelights,besuretheauxiliary(AUX)circuitsthatcontroltheIntelliBrite®Lightshavebeenassignedasan“IntelliBrite”light.Formoreinformationabout“CircuitFunctions”(page44)and“CircuitNames,”(page45).

Lights MenuToaccesstheLightsmenuscreen,pressMenu > Lights.TheLightsmenusettingsare:MODES,COLORS,ALLON,ALLOFF,SYNC,MAGICSTREAM,CONFIG:

MENUsLIGHTSwLIGHTS

Modes (IntelliBrite Color light shows, Color Swim, Color Set)ToaccesstheModesmenu,pressMenu > Lights > Modes.Therearesixpre-programmedcolorlightshowstochoosefrom.Fromthe“Modes”screenyoucanselectvariouspresetshowcolorlightingeffects,suchas“Americanmode”and“Sunsetmode”,“ColorSwim”or“ColorSet.”Usingthe“Hold”and“Recall”feature(seepage26)youcanalsocaptureandsaveauniquecolorlightshoweffecttorecallatalatertime.

TheIntelliBritecolor“Mode”settingslightshowsare:

• Party: Rapidcolorchangingbuildingtheenergyandexcitement

• Romance:Slowcolortransitionscreatingamesmerizingandcalmingeffect

• Caribbean: Transitionsbetweenavarietyofbluesandgreens

• American:Patrioticred,whiteandbluetransition

• Sunset:Dramatictransitionsoforange,redandmagentatones

• Royalty: Richer,deeper,colortones IntelliBrite Light: If the IntelliBrite light was not previously on, after selecting a color show mode, no illumination will occur for up to ten (10) seconds (depending on the selection), then a white light will momentarily illuminate, followed by the color show mode selection. If the light was previously on, selecting the a color show mode button will momentarily illuminate the previously selected color before changing to the selected color show.

Modes (Color Swim)TheColorSwimfeaturecyclesthroughwhite,magenta,blueandgreencolors.UsingIntelliBritelights,ColorSwimemulatestheSAm®,SAL® ColorSwimfeature. IntelliBrite Light Color Swim/Color Set: If the light was not previously on, after selecting Color Swim, no illumination will occur for approximately six (6) seconds followed by the selection. If the light was previously on, after selecting the Color Swim feature, the previously selected color will momentarily illuminate, no illumination will occur for approximately six (6) seconds followed by the selection.

FromtheLightsscreenyoucanmanuallyswitchalllightsonoroff,synchronizecoloredlights,andactivatecolorlightshows.Uptothree(3)lightcircuitscanbeconfiguredfromthe“Config”lightmenu.Eachlightmusthaveitsownrelayandseparatecircuit

Page 34: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

26

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Setting up lights (Continued)

Modes (Color Set)The“ColorSet”featureallowsanycombinationofuptothreeIntelliBrite®,SAm®,SAL®,and/orFIBERworks® lightingtobepresettospecificcolors.FixedlightcolorsareselectedandactivatedfromtheColorsscreen.

IntelliBrite Light: If the light was not previously on, after selecting the fixed colored light, no illumination will occur for approximately six (6) seconds followed by the selection. If the light was previously on, after selecting the colored light, the previously selected color will momentarily illuminate, no illumination will occur for approximately six (6) seconds followed by the selection.

ColorsChooseanyoneofthefivefixedcolorstocreateaspectacularunderwaterlightingeffect.Thefixedcolorsare:Blue, Green, Red,WhiteandMagenta.YoucanswitcheachfixedcoloredlightonorofffromtheColorsscreen.

IntelliBrite Light: If the light was not previously on, after selecting a fixed colored light, no illumination will occur for up to ten (10) seconds (depending on the selection), then a white light will momentarily illuminate, followed by the color selection. If the light was previously on, selecting the a color button will momentarily illuminate the previously selected color before changing to the selected color.

Toselectafixedcolorpress:Menu > Lights > Modes > Colors:

Up/Down buttons: Chooseacolorforthelight. Right button: SwitchtheselectedcoloredlightON.Toswitchthelightoff,goto themainLightsmenuandselectAll Off,orpresstheAUXbuttonassignedtothe light.TheAUXbuttonwillalsoswitchthelighton. PresstheMenubuttonthreetimestoreturnmainmenu.

Hold/RecallSelectHoldandRecallfromthe“Modes”or“Color”screentocaptureandsaveauniquecoloreffectandrecallitatalatertime.Forexample,whilealightshow(RomanceMode)isactive,select“Hold”tosavetheexactcolorsthatarebeingdisplayed,thenlater,torecalltheexactcoloreffect,select“Recall.” Note: After selecting HoldorRecall, no illumination will occur for up to 10 seconds, then a white light will momentarily illuminate, followed by the saved color.

All On / All Off (Lights Menu)SelectAll OnorAll OfffromtheLightsscreentomanuallyswitchalllightsonoroff,includinganyMagicStreamlaminarcircuits.Pressthecontrolpanelauxiliarybutton(AuxX)assignedtoalightcircuitwillalsoswitchalightonoroff.

SyncSelectSyncfromthe“Lights”screentosynchronizecolorsforallIntelliBrite,SAm,SALandFIBERworks colorchanginglights.

WARNING-IntelliBriteLights:Duringtheoff/onswitchingprocess,beforetheselectedcolorisdisplayed,noilluminationwilloccur.Thisoperatingmodeisnormalduringtheswitchingprocess.Duringthisperiodthepoolandspawillbedarkandprecautionsshouldbetakentoavoidunforeseenaccidents.Failuretoobservethiswarningmayresultinseriousinjuryordeathtopoolandspausers.

Blue Green Red White

Green Red White Magenta

Magenta

Page 35: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

27

Setting up lights (Continued)

ConfigFromthe“Config”screenyoucansetuptheIntelliBritelightposition,andspecifythecolorofeachpoolandspalight.Anycombinationofuptothree(3)IntelliBrite®,SAm®,SAL®,and/orFIBERworks® lightscanbepresetforspecificcolorsandpositionwhenusingthe“ColorSwim”and“ColorSet”feature.FixedlightcolorareselectedandactivatedfromtheColorsscreen.Note: The “Config” menu settings do not apply to the MagicStream laminars.

Toselectconfigurealightpositionandcolor:

MENU sLIGHTS wCONFIG

Up/Down buttons: Choosethelightcircuit(1-3)toconfigure.Selectanavailable auxiliarycircuit(NONE).Formoreaboutassigninganauxiliarycircuittoalight, see“CircuitFunctions(page44)and“CircuitNames”(page42). Thesystemsupportsuptothree(3)auxiliarycircuits. Right button: Selectthelighttosetup. Up/Down buttons: Selectthelightcircuit. Right button: Movetothelightcolorselection. Up/Down buttons: Selectthelightcolor(Blue, Cyan, Green, Lt. Green, White,Lt. Magenta,Magenta,Lavender). Right button: Movetothelightpositionselection.

Setting up SAM, SAL, PG2000, Color Wheel LightsBeforeusingthelightingfeature“ColorSwim”or“ColorSet”withSAMorSALlights,makesuretheAUXrelaycircuitswhichcontrolthelightshavebeenassignedas“light”circuitandthatthename(AUX1,AUX2,AUX3)hasbeenchangedtobestfitthelightbeingused.VerifythatSAmand/orSAL,and/orFIBERworkshavebeenassignedin“CircuitFunctions”asSAMorSALlight.IfFIBERworkslightingisincorporated,italsohastobesetupasa“PHOTONGENERATOR”lightforthecircuitcontrollingthelightbulb,andCOLORWHEELforthecircuitcontrollingthecolorwheelitself.Thecircuitlight“functions”are:Light,SAM,SAL,PhotonGenerator,ColorWheel,andIntelliBritelights,seepage45foracompletelistofPresetCircuitFunctions.

Up/Down buttons: Selectthelightposition.Alightcanbeassignedtoanypositionfrom1through12.Toensurethatthe“ColorSwim”and“ColorSet”lightingfeaturecoloreffectsarecorrect,setthepositionofthelightaccordingtowhereit’slocatedinthepoolorspa.Position 1willleadalltheotherlightsinthecolorchangingsequence.Position 2followsPosition1andsoon.Thereare12positiontochoosefrom.Morethanonelightmaybeassignedtothesamepositionnumbersothattheircolorsmaybesynchronized.Forexample,tomakethecolorsswimrighttoleft,makeyourrightmostlightPosition1.Youmayneedtogobacktoandscrollthroughyourlightstofindtherightmostlight,andsetitasPosition1. Right button: Movetothelightdelayselection.TheDelaytimebetweentwoormorelightscanbesetfrom0to60seconds.Useahigherdelaytimeforlightsspreadfurtherapart.Tryfivesecondsforalllightsandobservetheeffect.Usedifferenttimesettingstoachieveuniquelightingmoodsandeffects. PresstheMenubuttontosetupotherlightsorpressMenubuttonfourtimestoreturnmainscreen.

1- [POOL ] 2- [SPA ] 3- [BACK YARD ]

[ AUX 3 ] [ MAGENTA ] [ 1ST POSITION ] [ DELAY 5 SECS ]

Page 36: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

28

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Setting up MagicStream® LaminarsTheMagicStreamLaminarprovideaclear,turbulence-freestreamofwaterthatislitwithafiberopticcable,oranLEDlightforadazzlingnighttimeeffect.The12VACpoweredLEDlightcangenerateaseriesofmulticoloredlightshows,orcanbesettodisplayacontinuous,singlecolor.Ifdesired,thebuilt-insolenoid“thumper”cancreatearandom“wrinkle,”intheLaminar’sstream,causingittodisplayabrilliantspotoflightthatmovesalongthestream’sarc.Thelightenhancercanbeadjustedtomaximizethelightinthearc.

Uptothree(3)MagicStreamLaminarcircuitscanbedisplayedonthemainLightsscreen,assumingeachlaminarhasitsownrelayandseparatecircuit..FromtheLightsscreenyoucanactivatetheMagicStreamlaminars(changingcolormodes,turnThumperon/off,HoldandReset,seepage29).Formoreinformation,seetheMagicStreamLaminarInstallationGuide,P/N520969.

Setting up MagicStream Laminar LED LightsTosetupMagicStreamlaminarcircuits,firstassigneachlaminarauxiliaryrelaycircuitacircuitname(see“CircuitNames”page42,thenassignedthelaminarrelaycircuitnameto“MAGICSTREAM”inthecircuitfunctionsmenu(CircuitFunc.).

TosetuptheMagicStreamlaminarcircuitnamesandfunction:

MENUsSETTINGSsCIRCUIT NAMES

Up/Down buttons: Selectthecircuitnumber1/7.PresstheUp buttontwotimestoselectAUX1tochoosethiscircuitfortheMagicStreamlaminarcircuitOn/Offbutton.Thegenericcircuitsnamesare:Spa,Pool,Aux1-3,FEATURE1-2(Ft.1-2). Thecircuitnumber(1/7)correspondstoitsassignedcircuitname. Right button: Selectoneofthesystempresetcircuitnamesand/oruserdefinedcustomcircuitnames. Up/Down buttons: Scrollthroughthelistofpresetnames(seepage38foracompletelistofcircuitnames).SelectanamethatdescribeswheretheMagicStreamlaminarislocatedorthatsuitsthefunction,suchas“Stream.”AUX1hasnowbeenassignedthecircuitname“Stream.”forthefirstMagicStreamlaminar.Repeatthisstepforthenextlaminarcircuit.Ifyoucannotfindanametomatchyourcircuit,youcancreateyourowncustomname(seepage46). PresstheMenubuttontoreturntotheSettingsmenu.PresstheDownbuttontoandselect“CircuitFunc.”PresstheRight button toaccess theCircuitFunc.menu.

Up/Down buttons: Selectthealreadyassignedcircuitname“Stream.” Right button: Viewthe“CircuitFunctions”toassigntolaminarcircuit“Stream.”Up/Down buttons: Selectthetypeofcircuitfunctiontouse,inthiscaseselect“MAGICSTREAM.”Thecircuitfunctionnamesare:LIGHT,SAMLIGHT,SALLIGHT,PHOTONGEN,COLORWHEEL,VALVE,SPILLWAY,FLOORCLEANER,INITELLIBRITE,MAGICSTREAM,GENERIC,andMSTRCLEANER.Foracompletelistofpresetcircuitfunctions,see“PresetCircuitFunctions”onpage45.

Right button/ Up Button: Turn“Freeze”protectionON.

PresstheMenubuttonthreetimestoreturntothemainscreen.

MENU sSETTINGSsFUNC.

Continue on next page.

Circuit Names Circuit #: 1/7 Circuit : AUX 1 [STREAM ]

IntelliFlo IntelliChlor Circuit Names Circuit Func.

Circuit / Func. : [STREAM ] [MAGICSTREAM ] Freeze: Yes

Page 37: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

29

Using the MagicStream® Laminar FeaturesTheMagicStreamlaminarfeaturesaredisplayedintheMagicStreamlaminarmenu.EachtimeaMagicStreamlaminarfeatureisactivated,itresumeswiththesamefeaturesinoperationaswhenlastswitchedoff.TheMagicStreamfeaturesareasfollows:

Toggle Thumper - Pressingthisbuttoncreatesa“wrinkle”inthelaminarstream,producingabrilliantspotoflightinthelaminararc.

Hold - SelectHoldtocapturethecurrentcoloreffectwhilecolorsarechanging.Thecolorswillstopchanging.SelectingHoldagainwillresumethecolorchangingmode.

Reset-PressingthisbuttonrevertstotheRandomcolorchangingmodewiththeThumperON.

Change Mode - Pressingthisbutton(eachsuccessiveOFF/ONcombination)willcyclethroughSync, RandomandParty.Colorchangingmode-Thecolorofthelightchangesautomatically,accordingtoonethefollowingthreeprograms:

Sync -Colorswillchangeattensecondintervals.Inthismode,multiplelaminarswillsynchronizecolorstogether.Note:Tosyncmultiplelaminars(twoormoreAUXcircuits),besuretodefinethe“MagicStream”circuitsinthe“CircuitFunctions”menu.

Random-Colorswillchangeatten(10)secondintervalsinarandomsequence.Inthismode,multiplelaminarswillNOTsynchronizecolorstogether.

Party -Colorswillchangerandomlyandslowlyatfirst,thenspeedup,untilthesequenceendswithquickflashesandstrobes.Thesequencethenrepeats,beginningwiththeslowchanges.Inthismode,multipleLaminarswillNOTsynchronizecolorstogether.

ToaccesstheMagicStreamlaminarfeatures:

MENUsLIGHTSwLIGHTS

Down button: ChooseMagicStream. Right button: SelectMagicStream. Up/Down button: SelectthedesiredMagicStreamlaminarfeatures. Right button: UsethisbuttontoactivatetheselectedMagicStreamlaminar feature.Afterthebuttonispressed,thefollowingscreendisplaysthenameofthe selectedfeature(indicatingthattheMagicStreamfeaturehasbeenactivated) thenreturnstotheMagicStreamlaminarfeaturemenu.

PresstheMenubuttonthreetimestoreturntothemainscreen.

All On All Off Sync MagicStream

Toggle Thumper Hold Reset Change Mode

Change Mode

Page 38: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

30

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Heat MenuUsetheheatmenusettingstospecifythesetpointtemperatureandselecttheheatsourceforthepoolandspawater.Thewaterwillbegintoheatwhenevertheheaterismanuallyswitchedon,(bypressingtheValves(V)button(ontheOutdoorControlPanel)orthe“Pool”or“Spa”buttonontheIndoorControlPanelandWirelessController),eveniftheheaterissettooff.TheEasyTouch®PL4/PSL4ControlSystemallowsforsolarandconventionalheaters.Thesystemwillusetheheatingsourcethatisselected.Theheatsourceselectionsare:

• OFF -Noheatingeventhoughpumpandothercircuitsmaybeoperating.• HEATER - Gasheateronly.UsetheHeaterbuttontoautomaticallyswitchtheheateronwhich

controlstheoutputbetweena“forcedoff”stateandanormal,automaticthermostaticcontroloperatingstate.Theheaterwillcontinueheatingthewateruntiltheheater’scurrenthighestsetpointtemperaturetriggerstheheatersensor(approximately104°F(40°C).NotethattheHeaterbuttononthecontrolpaneldoesnotactivatethepump.Donotactivatetheheaterwithoutrunningthepump.Theheaterwillnotrunifwaterflowisnotdetected.

• SOLAR ONLY-Solarheatingsystemtobetheonlyheatsource.Inordertodisplay“SolarPref.”onthemainscreen,youmustfirstenablesolarinthe“Solar”menu(seepage47).

• SOLAR PREF. (Solar Preferred)-Solarandgasheatingsystemsareinstalled,andyouwanttousesolarheatingonlywhenitismosteffective.Inordertodisplay“SolarPref.”onthemainscreen,youmustfirstenablesolarinthe“Solar”menu.Tosetthespatemperatureandselecttheheatsource:

Pool Temp/Src

Tosetthepooltemperatureandselecttheheatsource:

MENUsHEAT

Right button: Selectpooltemperatureandheateroptions. Up/Down button: Setthepooltemperaturefrom40°Fto104°F(4°C-40°C). Right or Left button: MovetoHeateroption. Up/Down: SetHeateroption:Off, Heater, Solar, orSolar Preferred.

PresstheMenubuttontosavethesettingsandtoreturntothepreviousmenuorpressthebuttonagaintoreturntothemainscreen.

Spa Temp/Src

Tosetthespatemperatureandselecttheheatsource:

Right button: Selectspatemperatureandheateroptions. Up/Down button: Setthespatemperaturefrom40°Fto104°F(4°C-40°C). Right or Left button: MovetoHeateroption. Up/Down: SetHeateroption:Off, Heater, Solar, orSolar Preferred. PresstheMenubuttontosavethesettingsandtoreturntotheHeatmenuorpressthebuttonagaintoreturntothemainscreen.

Note: For the EasyTouch PL4 Control System single body system, “Pool” and “Spa” modes are Lo- Temp (Pool) and Hi-Temp (Spa) temperature controls. For more information, see “Hi-Temp/Lo-Temp Controls for Single Body Systems,” on page 42.

POOL Temp: 72° F Heat: Off

POOL Temp/Src SPA Temp/Src

SPA Temp: 85° F Heat: Off

POOL Temp/Src SPA Temp/Src

Page 39: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

31

Delay Cancel MenuUsetheDelayCancelfeatureforserviceortestingpurposes.Forconvenience,onaonetimebasis,theDelayCancelfeaturewillcancelthefollowingsafetydelays.Pleasenote,generallythereisnoneedtocancelanyofthefollowingdelaysexceptforservicingortestingthesystem.

• Heater Cool-Down Delay Cancel:ShutsFilterPumpoffimmediately.• 2-Speed Filter Pump five-minute START on HIGH SPEED Delay Cancel:Shiftspumptolow

speed.• Automatic Pool Cleaner START Delay:StartsCleanerPumpimmediately,withoutnormaldelayin

whichthefilterpumpfirstrunsfor5minutes.• Automatic Pool Cleaner SOLAR Delay:AllowsCleanerPumptoruneventhoughsolardelayhas

shutitofffor5minutes.Someheatersrequireacool-downcyclebeforebeingswitchedoff.Thiscanbesetupinthemenutorunthefilterpumpanadditionaltenminutestodissipateresidualheatbuiltupinsidetheheatercombustionchamber.TheDelayCancelfeatureismainlyforusebyservicetechnicianswhenit’snecessarytoshutthefilterpumpoffimmediately,andknowtheheaterhasnotbeenrunning.HeatersmanufacturedbyPentairWaterPoolandSpadonotrequirethiscool-downperiodanddonotneedthedelaytobesetup.

Note: For Information about assigning delays to the pool and spa valves, refer to “Settings Menu: Delays” on page 48.

Delay Cancel

ToactivateDelayCancel:

MENUsDELAY CANCELw

Up/Down button: SelectDelayCancel. Right button: UsethisbuttonactivateDelayCancelforonetimeonly.“DelayCancelled”isdisplayedafterpressingtheRightbutton.

PresstheMenubuttontoreturntothemainscreen.

F. Circuits Lights Heat Delay Cancel

Page 40: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

32

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Schedules MenuUsetheSchedulesmenutocreateprogramstoschedulestartandstoptimestoautomaticallyrunequipment,suchaspumpsandlights.Anycircuitcanbeprogrammedtoswitchonandoffataspecifictimeoneveryoranyspecificdayoftheweek.Thenumberofprogramsthatcanbecreatedforcircuitsareasfollows:

• Up to four (4) programs can be created for all circuits combined.

• Onecircuitcanhaveuptoamaximumoffour(4)programs(1/4).Programsthatcanusedbycircuitsfora total of four (4) programs.

Using the Schedules menuUsetheSchedulesmenufeaturestoprogramoperatingschedulesforthepool,spaandauxiliarycircuits:

MENUsSCHEDULES wSPA

Choose the circuit to program Up/Down button: Selectthegenericcircuitnametoprogram:Spa,Pool,Aux1-3,Feature1-2. Thecurrentnumberofprogramsforeachcircuitisdisplayedoppositethecircuitname.Acircuitcanhaveupto4programs(1/4).Threeadditionalprogramscanbeassignedtoanothercircuitorthreeseparatecircuitsforamaximumofseven(7)programs.

Create a new program Thecurrentnumberofprogramsforeachcircuitisindicatedoppositetothecircuitname.0/0indicatesnoprogramsassignedtothiscircuit. Right button: Tomovetothe“Mode”selection. Up/Down button: SelectNewtocreateanewprogram.Use“None”whenacircuithasexistingprogramsandyouwishtoexitthe“Mode”selectionswithoutmodifyingtheexistingprograms.

Choose the type (Mode) of program to run Afterselecting“New”thecurrentprogramnumber(1/1)forthiscircuitisdisplayed. Right button: Tomovetothe“Mode”selections. Up/Down button: Choosetheprogramtorun:Schedule, Egg Timer, New, Delete, and None.Ifthereareexistingprogramsassignedtothiscircuit,usethesebuttonstoviewandselecttheexistingprogramsettings. Mode Selection: Schedule:Setstart,stoptimesandtheday(s)oftheweektoautomaticallyswitchpool/spacircuitsonoroff.Defaultruntimeforthe“Schedule”featureis8:00AMto5:00PM.Ifyouprogramthestartandstoptimesthesamethescheduleiswillrunfor24hours.

Egg Timer: Aonetimeprogramthatswitchesonafunctionataspecifictime,andcountsdownthepresettimetotheswitchoffthefunction. Afterthe“EggTimer”schedulehasfinished,thesystemcanbeoperatedinmanualmode.The“DON’TSTOP”optionallowsacircuittoruncontinuouslyuntilitsswitchedoffmanually.

New:presstheRight buttontocreateanewprogram.

Delete:SelecttheprogramandpresstheRight buttontodeleteit.

None:PresstheRight buttontoexitthe“Mode”selectionswithoutmodifyingtheprogram.

SPA 0/0 Mode: None

SPA 0 POOL 0 AUX 1 0 AUX 2 0

SPA 1/1 Mode: Egg Timer Timer: 12:00

SPA 1/1 Mode: Delete

SPA 1/1 Mode: None

SPA 0/0 Mode: New

SPA 1/1 Mode: New

SPA 1/1 Mode: Schedule 08:00A - 05:00P smtwtfs

Page 41: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

33

Using the Egg Timer (countdown) FeatureThe“EggTimer”featureallowsyouswitchoffacircuitautomaticallyafteraspecifiedtime.Thetimeperiodisfromoneminuteto24hoursorruncontinuously.The“EggTimer”(countdown)featureisusefulforswitchingofflightingandspatherapyjets.Forexample,ajetpumpcanbesetuptoswitchoffin15minutes,evenifyouswitchitonusingtheiS4Spa-SideRemoteorQuickTouch®IIWirelessRemoteorwheneveryouswitchyourspaon,youwouldlikeittoautomaticallyswitchitoffintwohours.AllEggTimerprogramsarefactorysettoswitchoffafter12hours.Youalsohavetheoptiontousethe“Don’tStop”featuretorunacircuitcontinuouslyuntilmanuallyswitchedoff.

Intheeventofapowerfailure,the“EggTimer”featurewillnotswitchthecircuitbackon.Theymustbeswitchedbackonmanually.Forrunningthefilterpumpcontinuouslyduringnewpoolstartup,itisrecommendedtousethe“Service”mode,whichwillautomaticallyrestartthefilterpumpintheeventofapowerfailure.

Thefollowingexampledescribeshowusethe“EggTimer”(onceonly)featuretoprogramthespacircuittoswitchthefilterpumponandrotatethevalvesintothe“Spa”positionandswitchtheheateronforonetimeonly.Thisexamplecanalsobeusedifyouwantedtoprogramwhentofilterandheatyourpool,andswitchlightorauxiliarycircuitson.

TosettheEggTimerfeature:

MENUsSCHEDULESwSPA

Press the Up/Down button to selectthecircuittoschedulethenpresstheRightbutton.

Right button: SelectMode ifthereareexistingprograms.Skipthissteptocreateanewprogram. Up/Down button: SelectNewtocreateanewprogram. Right button: Tocreateanewprogramandenterthe“Mode”settings. Up/Down button: 1/1indicatesthatthiscircuithasoneprogram.Ifthereareexistingprogramsassignedtothiscircuit,usethesebuttonstoviewandselecttheexistingprogramsettings. Right button: Toselectthe“EggTimer”settings. Right button: Movetothetimesettings. Up/Down and Right buttons: Setthehourandminutesfortheprogramtorun.Thecountdowntimecanbesetfrom00:01to23:59andDon’tStop.The“Don’tStop”featureallowsthecircuittoruncontinuouslyuntilmanuallyswitchedoff.

PresstheMenubuttontosavethesettingsandtoreturntotheSchedulesmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

SPA 1/1 Mode: Egg Timer Time: 12:00

SPA 0/0 Mode: None (New)

SPA 0 POOL 0 AUX 1 0 AUX 2 0

Page 42: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

34

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Settings Menu: ClockUsetheClockmenutosettheEasyTouchPL4/PSL4ControlSystemdateandtime.Theday,timeandAM/PMisdisplayedonthemainscreen.Thesystemclocksettingsareusedforthesystemscheduledoperations.ThesystemclockwillcontinuetorunifpowerisremovedfromthesystematthePowerCenter.

Clock

Tosetthesystemdateandtime:

MENUsSETTINGS wCLOCK

Right button: Movetothedaysetting. Up/Down buttons: Setthedayofthemonth. Right button: Movetotheyearsetting. Up/Down buttons: Settheyear. Right button: Movetothenextsetofsettings(2/2). Up/Down buttons: SetDaylightSavingstoAutoorManual.Autokeeptrackofthesemiannualtimechanges.Ifyoudonotliveinanareathatobservesdaylightsavingstime,chooseManual. Right button: Movetotheclockadjustmentsetting.Iftheinternalsystemclocklosestimeduringthemonth,usethissettingtosetthenumberofsecondsinfivesecondincrementspermonthtoautomaticallyadjusttheclocktothecorrecttime. Up/Down buttons: Adjusttheoffsetinfivesecondincrements.

PresstheMenubuttontosavethesettingsandtoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Settings Menu: IntelliFlo® (IntelliFlo® and IntelliPro® pump)TheEasyTouchPL4/PSL4ControlSystemcommunicateswiththeIntelliFlopumpviaatwo-wireRS-485cable(PN350122).IntelliFlooperationscanbecontrolledfromtheEasyTouchPL4/PSL4ControlSystemIndoorandOutdoorcontrolpanelandtheWirelessController.Thesystemsupportsthefollowingpumps:

IntelliFloVS+SVRS(1100-3450RPM)

IntelliFloVS-3050(400-3110RPM)

IntelliProVS-3050(400-3450RPM)

IntelliFloVSF+SVRS.

Formoreinformationrefertothefollowingmanuals:

IntelliFloVS3050(P/N357269),IntelliFloVSF+SVRS(P/N351420).

How many IntelliFlo pumps will EasyTouch PL4/PSL4 Control System support?

EasyTouchPL4/PSL4ControlSystemcansupportoneIntelliFlo®(orIntelliPro)orIntelliFloVS3050(orVSF+SVRS)pumpsinwithuptofourGPMsorRPMs.

Note: IntelliFlo pumps cannot be connected in series with other pumps. Check valves must be used when a pump is used in parallel with other pumps.

Date & Time 1/2 JAN 12 2009 09:20 AM

Date & Time 2/2 DayLt Sav: Auto Clk Adj: 00:00

Page 43: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

35

IntelliFlo VS and VSF+SVRS Settings

Selecting the IntelliFlo PUMP TYPEToaccesstheIntelliFlomenu:MENUsSETTINGSsINTELLIFLOwPUMP#1

Up/Down button: ChoosePump #1. Right button: SelectPump #1. Right button: SelectPump Type.Note:TochangethecurrentpumptypeforPump#1.presstheUp/DownbuttonandselectY,thenpresstheRight button.TocontinuetothePump#1settingsmenu,presstheRight button (orMenutoexit).

Settings Menu: IntelliFlo® Pump (Continued)

Connecting Power to the IntelliFlo PumpTheIntelliFlopumpisdesignedtobepermanentlyconnectedtoitspowersource.Typicallythepumpreceivespowerdirectlyfromthecircuitbreaker.Nocontactorormotorstarterisrequired.Thedrivecontrolsthestartingandstoppingofthepump.IftheIntelliFlopumpisconnectedtoanautomationsystem,suchastheEasyTouchPL4/PSL4ControlSystem,thedrivemustbepowereduptoreceiveandrespondtotheRS-485serialcommunicationfromtheautomationsystem.However,thepumpcanbeoperatedin“stand-alone”mode,startingandstoppingwhenpowerisappliedorremoved.Whenthedrivepowersupitwillreturntothemodeandrunstatusthatitwasinwhenpowerwasremoved.Thissetupisappropriateifyouneedtouseexistingrelaysortimers.

Assigning an IntelliFlo VS 3050 pump addressBeforeassigningapumpaddressattheEasyTouchPL4/PSL4ControlSystemindoor,wirelessoroutdoorcontrolpanel,firstsettheaddresson the pump itself.Thepump'sdefaultaddressispump#1.

ToassignanIntelliFloVS3050pumpaddress:

1. BesurethatthepumpispoweredonandthegreenpowerLEDison.

2. PresstheStop buttonstostopthepump.3. PressandholdboththeStart and Stop buttonsuntilthered

LEDwillstartsflashing,thenpressoneofthefourspeedbuttons(1-4)toselectwhichaddresstoassignthepump.Forexample,ifyouareassigningthepumpaspump#1,thenpressSpeedbuttonnumber1.

4. PressandholdboththeStart and Stop buttonstosavetheaddress.Repeattheprocessfortheotherpumps.

NOTE: INTELLIFLO IN “SERVICE MODE” - IntelliFlo pumps will STOP when the system is in ‘Service” mode.

NOTE: INTELLIFLO “FREEZE” PROTECTION - If the IntelliFlo pump is on due to a freeze condition (not switch on from a relay circuit), and if a freeze protect for a certain speed is set, this setting takes priority even if the previous setting is lower than the default circuit speed. If no “freeze” protection is set, the pump will be forced on at the default circuit speed. Any programmed or manual operation that actually switches on a circuit, will cause the pump to run at that speed if it is higher.

SELECT PUMP TYPE: Up/Down buttons: ChooseVSorVSF+SVRS. Menu button: PresstheMENUbuttontosaveselectionandreturntotheselectedpump’smenusettings(seeVSandVSFpumpsettingsdescriptionsbelow)

Pump #1

Changing Pump1’s Type will config it to default. Continue ? N

Pump Type Speeds Priming Status

IntelliFloVSPumpSpeedbuttons(1-4)

Speed1

Speed2

Speed3

Speed4

Page 44: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

36

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

INTELLIFLO VS SPEEDS SETTING: Down button: ChooseSpeeds. Right button: AccesstheIntelliFloVSspeed(RPM)settings forPump#1. Up/Down button: Selectthecircuit number 1 of 4(1/4). Right button: MovetoRPMtochangethepumpspeed. Up/Down buttons: Setspeedofthepumpfrom400to3450RPMinincrementsof10RPM.ThedefaultspeedforeachcircuitcorrespondtothefourspeedbuttonsontheIntelliFloVScontrolpanelis:Speed 1 button 750 RPM, Speed 2 button 1500 RPM, Speed 3 button 2350 RPM, and Speed 4 button 3110 RPM.

INTELLIFLO VSF+SVRS FLOW RATE SETTING: Down button: ChooseFlow/Speeds. Right button: AccesstheIntelliFloVSF+SVRSspeed(RPM/GPM)settings forPump#1. Up/Down button: Selectthecircuit number 1 of 4(1/4). Right button: MovetoGPMtochangethepumpflowrate. Up/Down button: SelectRPM or GPM.PressUp/Down buttontotogglebetweenRPMandGPMandpressuresetting(PSI). Right button (GPM): MovetoGPMpumpflowrate. Up/Down button: Setspeedofthepumpfrom15to130GPM.Thedefaultflowrateis30GPM.Thepresetspeedforeachbuttonis:Speed 1 button 1100 RPM (30 GPM), Speed 2 button 1500 RPM, Speed 3 button 2350 RPM, and Speed 4 button 3110 RPM. Right button (GPM/PSI):MovetoPSI(poundspersquareinch)pressuresetting. Up/Down button: Selectthepumppressuresettingfrom1to30PSI. See above for equivalent default RPM/GPM (speed/flow rate).

VS and VSF+SVRS CIRCUIT SETTING: Right button: Movetothecircuitnames. Up/Down buttons: Assign the pump circuit: NONE, SPA, POOL, AUX 1-3, FEATURE 1-2, HEATER, POOL HEATER, SPA HEATER, FREEZE, POOL/SPA, and SOLAR/HEAT. Right button: PresstheUp arrow buttonandgotothenextcircuitpagesettings (2/4)andrepeattheprevioussteps.

Whenfinishedsettingupthecircuits,presstheMenubuttontosavethesettingsandtoreturntotheSettingsmenuoptions.Pressthebuttontwotimestoreturntothemainscreen.

INTELLIFLO VS STATUS SETTING: Down button: ChooseSTATUS. Right button: ViewthecurrentIntelliFloVSpumpstatus. Menu: PressMENUtoexit.

IntelliFlo VS and VSF+SVRS Settings (Continued)

Pump #1 Type Type: VS

Pump #1 1/4 RPM: 1200 Circuit: [ POOL ]

Pump #1 1/4 GPM:30 PSI: 15 Circuit: [ NONE ]

Pump Type Flow/Speeds Status

Pump #1 Type Type: VSF+SVRS

Pump #1 1/4 GPM:30 PSI: 15 Circuit: [ AUX 1 ]

GPM: 30 1200 RPM 12 W Watts: 10 Status: GOOD

Page 45: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

37

INTELLIFLO VS STATUS SETTING: Down button: ChooseSTATUS. Right button: ViewthecurrentVSstatus. Menu: PressMENUtoexit.

IntelliFlo VF 3050 pump SettingsAssigning an IntelliFlo VF 3050 Pump Address

Beforeassigningapumpaddress,firstsettheaddresson the pump itself.Ifthereisonlyonepump,itisalwaysseenaspump#1bytheEasyTouchPL4/PSL4ControlSystem.Inthiscaseyoudonotneedtosetthepumpaddress.Theaddressshouldbesetto#1.TheaddresssetatthepumpmustmatchtheIntelliFlopumpnumberselectedinthesystemIntelliFloPUMP # > PUMP TYPE menus.

Note: IntelliFlo VF 3050 pumps cannot be connected in series with other pumps. Check valves must be used when a pump is used in parallel with other pumps.

ToassignanIntelliFloVF3050pumpaddress:

1. PresstheStart/Stopbuttontostopthepump.BesurethatthegreenpowerLEDisonandthepumpisstopped.

2. PresstheMenu button.3. PresstheUp and Downarrowbuttonstoscrollthroughthemenuitems.PresstheSelectbuttonto

accessthe“PoolData”menu.4. PresstheSelect buttontoaccessthe“PumpAddress”setting.5. PresstheSelect buttontochangethecurrentpumpaddress.6. Toenterthenewaddressnumber,presstheLeftandRightarrowstoselectwhichdigittomodify,

thenusetheUpandDownarrowstochangetheselecteddigit.7. Whenyouaredoneassigningthepumpaddressnumber,presstheEnterbuttontosavethechanges.

Tocancelanychanges,presstheEscapebuttontoexiteditmodewithoutsaving.

NOTE: INTELLIFLO “FREEZE” PROTECTION - If the IntelliFlo pump is on due to a freeze condition (not switch on from a relay circuit state), and if a freeze speed/flow is set, this setting takes priority even if the previous setting is lower than the default circuit speed. If no “freeze” protection is set, the pump will be forced on at the default circuit speed/flow. Any programmed or manual operation that actually switches on a circuit, will cause the pump to run at that speed if it is higher.

NOTE: INTELLIFLO IN “SERVICE MODE” - The IntelliFlo pump will STOP when the control system is in ‘Service” mode.

NOTE: INTELLIFLO VF PUMPS - If the IntelliFlo VF pump is just starting (requiring a prime) and SOLAR is available, solar will be delayed for five (5) minutes to allow the pump to prime. This only applies for IntelliFlo pump(s) assigned as to a “pool” pump.

INTELLIFLO VS PRIMING SETTING: Down button: ChooseSPEEDS. Right button: Accesstheprimingsettings. Up/Down button: Adjusttheprimingtimefrom0to5minutes. Right button: MovetoSPEED (RPM)tochangethepumpspeed. Up/Down buttons: Setspeedofthepumpfrom400to3450RPMinincrementsof10RPM.ThedefaultspeedforeachcircuitcorrespondtothefourspeedbuttonsontheIntelliFloVScontrolpanelis:Speed 1 button 750 RPM, Speed 2 button 1500 RPM, Speed 3 button 2350 RPM, and Speed 4 button 3110 RPM.

IntelliFlo VS and VSF+SVRS Settings (Continued)

Pump Priming Time: 0 Speed: 1000

Pump Status RPM: 1200 Watts: 10 Status: GOOD

Pump Type Speeds Priming Status

Pump Type Speeds Priming Status

Page 46: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

38

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Settings Menu: IntelliChlorWhiletheEasyTouch®PL4/PSL4ControlSystemisinnormaloperatingmode(“Pool,”“Spa”modeor“SpaFill(Spillway),”itwillcontroltheIntelliChlor®SaltChlorineGenerator(SCG)chlorineoutputlevel.Theamountofchlorineintroducedintothepoolisdeterminedbytheamountofsaltinthewater,watertemperature,andtheamountoftimethepoolpumpisrunningin“Pool”mode.Note:Whilein“FreezeProtection”mode(seepage44),theIntelliChlor(SC)willnotoperateorproducechlorineduringthetimethatthefilterpumpisoperating.Formoreinformation,refertotheIntelliChlorSaltChlorineGeneratorUser’sGuide(P/N520589).

IntelliChlor

TosetuptheIntelliChlor®SCG:

MENUsSETTINGSsINTELLICHLOR

Right button: Enable/DisabletheIntelliChlor.SCG(ToselectSuperChlor,runhours,presstheUp/Downbutton-2/2). Up/Down buttons: SelectYesorNotoenableordisabletheIntelliChlor(SC). Right button: POOLMode“50%”setting. Up/Down buttons: Setthechlorinationoutputlevelforthepoolwaterfrom0to100%.EasyTouchPL4/PSL4ControlSystemwilldeterminethechlorinatoroutputlevelwhenthesystemisoperatingin“Spa”or“Pool”mode.Theamountofchlorineintroducedintothepool/sapisdeterminedbytheamountofsaltinthewater,watertemperature,andtheamountoftimethepool/spaoperatesinthesemodesmode. Right button: SPAMode“0%”setting. Up/Down buttons: Setthechlorinationoutputlevelforthespawaterfrom0to20%. Right button: Movetothenextsetofsettings(2/2). Up/Down buttons: Select2/2. Right button: MovetheSuperChlorinationsettings. Up/Down buttons: SetSuperChlorinationOnorOff.SeenotebelowaboutSuperChlorination. Right button: Moveto“RunHours”setting. Up/Down buttons: SetthenumberofhourstorunSuperChlorination.24hoursisthedefaultsetting.Runhourscanbesetfrom0to72hours. PresstheMenu buttontosavethesettingsandtoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Note: For IntelliChlor (SC) status messages, see “Diagnostics: Chlorinator” page 58.

About Super Chlorination: TheSuperChlorinationfeatureisusedtointroducelargeamountsofchlorineintothepoolwateriftherehasbeenheavyrainfall,manybathersinthepool,cloudywaterconditions,etc.WhenSuperChlorinationisenabled,thesystemwillswitchonthefilterpump,setthepool/spavalvestothecorrectposition,andsettheIntelliChlor(SC)tomaximumoutput.Thisprocesscontinuesfor24hours.AttheendoftheSuperChlorinationprocess,thepoolwillreturntonormaloperation.ItispossibletomanuallystoptheSuperChlorinationprocessandswitchoffthefilterpumpusingtheFilter(F)buttononthemaincontrolpanelatthepoolequipmentpad.WhenthefilterpumpisswitchedonagainusingtheFilter(F)button,theSuperChlorineprocesswillresumeforthedurationoftimeleft.

IntelliChlor 1/2 Enable: No Level: 50%

IntelliChlor 2/2 Super Chlr: Off Run Hours: 24

Page 47: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

39

IntelliChem

ToaccesstheIntelliChemControllerpHandORPsettings:

MENUsSETTINGSsINTELLICHEM

PH/ORP Values:PresstheRight buttontoaccessthepHandOPRsetpointvaluesscreen.UsetheUp/DownbuttontoadjustthepHsetpointvalue.PresstheRight buttonagaintosettheORPsetpointvalue.PressMENUtosaveandreturntothepreviousscreen.

pH Set Point: DisplaysthecurrentpHsetpointvalue.Theadjustablerangeisfrom7to8inincrementsof0.1.ThedefaultpHsetpointvalueis7.5.

ORP Set Point:DisplaysthecurrentORPsetpointvalue.UsetheUp/Down button to adjusttheORPsetpointvalue.Theadjustablerangeisfrom650to800inincrementsof10.ThedefaultORPsetpointvalueis700(chlorinelevelof3.0ppm).TheORPsetpointisthevaluethatIntelliChemwilltrytoachievebasedontheactualchlorinelevel(ppm).

STATUS:DisplaysthecurrentcommunicationlinkbetweenEasyTouchPL4/PSL4andIntelliChemviatheRS-485cable.IChem Comm Error:ChecktheRS-485communicationcableisconnectedtotheCOMportontheEasyTouchPL4/PSL4ControlSystemmaincircuitboard.

Level Gauge indicator:PresstheUp/Down buttonto“fill”thegaugeiconsothatitvisuallyrepresentsthesameamountofacidavailableinthecontainer.PressUp/Downbuttonsix(6)timestofillthegauge(threetimestohalffillthegauge).Sixhorizontalbarsrepresentchlorine(orbromine)supplyisfull.Onebarindicatesthesupplyisnearlyempty.

IntelliChem®ControllerprovidestheEasyTouch®PL4/PSL4ControlSystemwithcontinualanalysisofyourswimmingpoolwatersanitationandpHlevels,providingreal-timestatusinformationtodispensetheproperamountofmuriaticacid(pHreducer)andchlorineorbromineforthecorrectsanitizationandpHbalance.IntelliChemcontrolleroperateswithorwithoutasaltchlorinegeneratortoprovideaself-replenishingsupplyofchlorinegeneratedfromsalt.Formoreinformation,refertotheIntelliChemControllerInstallationandUser’sGuide(P/N521363). FromtheIntelliChemcontrollermenuyoucanadjustthepHandOxidationReductionPotential(ORP)setpointvaluestomeetpoolandspachemistrystandardsforyourpool.AstatusscreendisplaysauseradjustablepHandOPRfuelgaugewhichvisuallyrepresentsthesameamountofchemicalsavailableinpHandORPcontainer.

Settings Menu: IntelliChem® Controller

Sat Index:ToaccesstheSatIndexsettings,presstheUp/Down buttonthenpresstheRight button.UsetheUp/Down buttontoadjustthelevels/valuesfor:CH (calcium hardness), TDS (Total Dissolved Solids), TA (total alkalinity), CYA (cyanuric acid) and TMP (current temperature). Note: See table below for ideal Saturation Index levels. SI: ThesaturationIndexisdisplayed.IDEAL:Optimumlevels.CORROSIVE:pHtoolow.SCALING: PresstheMenu buttonthreetimestoreturntothemainscreen.

Note: Use the Langelier Saturation Index (LSI) Calculator to diagnose the water balance in your pool. Water with a LSI of 1.0 is one pH unit above saturation. Reducing the pH by one unit will bring the water into equilibrium. To use the LSI calculator, refer to: http://www.pentairpool.com/pool-owner/resources/calculators/langelier/

Recommended Pool Chemistryph range: 7.2 to 7.6ORP range: 650 to 750Alkalinity: 80 to 120 ppmCalcium Hardness: 200 - 500 ppmCyanuric Acid/Stabilizer: 30 ppm

pH VAL 7.0 pH Set: 7.5 ORP VAL: 650 ORP SET: 750

IntelliChem PH/ORP Values Status Sat Index

IntelliChem PH/ORP Values Status Sat Index

IntelliChem PH/ORP Values Status Sat Index

CH: 245 TDS: 0TA: 75 CYA: 18SI: NA TMP: 0 IDEAL

Clock IntelliFlo IntelliChlor IntelliChem

pH Lv1: ORP Lv1: ICHEM: ON ORP Dosage Limit

Page 48: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

40

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

SAT INDEX:TheSaturationIndex(SI),alsocalledtheLangelierIndex,isachemicalequationorformulausedtodiagnosethewaterbalanceinthepool.TheSaturationIndexformulaisSI=pH+TF+CF+AF-12.1.TocalculatetheSaturationIndex,youmustfirsttestthepoolwaterforpH,temperature,calciumhardness,andtotalalkalinity.Refertoachartforassignedvaluesforyourhardness,andalkalinityreadingsthenaddthesetoyourpHvalue.Subtract12.1,whichistheconstantvalueassignedtoTotalDissolvedSolidsandaresultantnumberwillbeproduced.Aresultbetween-0.3and+0.5indicatesbalancedwater.Testresultsnotwithinthesevaluesrequirechemicaladjustmentstoachievebalance.Thisformulaismoreorlessreliablebutnotguaranteed.Insomecases,individualreadingsforpH,calcium,andalkalinitymightbebeyondnormalrecommendations,however,combinedwithintheformulacanproduce“balancedwater.”TheSIisusefultopinpointpotentialwaterbalanceproblems.

pH:pHproducedbytheIntelliChlor(SC)isclosetoNeutralpH.However,otherfactorsusuallycausethepHofthepoolwatertorise.Therefore,thepHinapoolchlorinatedbytheIntelliChlor(SC)tendstostabilizeatapproximately7.8.ThisiswithinAPSPstandards.IfthepoolpHrisesabove7.8,haveapoolprofessionaltesttoseeifotherfactorssuchashighCalciumHardnessorTotalAlkalinityarethecauseandthenbalanceaccordingly.

pH Level Test: TestthepHlevelofyourpoolwaterwithareliabletestmethod.Ifnecessary,adjustaccordingtoyourpoolprofessional’srecommendations.APSP’srecommendedidealrangeforpHis7.4to7.6.Note:Neverusedryacid(sodiumbisulfate)toadjustpHinaridgeographicareaswithexcessiveevaporationandminimaldilutionofpoolwaterwithfreshwater.AbuildupofbyproductscandamagetheIntelliChlor(SC).

Calcium Hardness: Recommendedrangeforcalciumhardnessis200-400ppm.CalciumHardnesslevelsshouldbetestedweekly.Calciumhardnessisthecalciumcarbonatescaledepositedonpoolsurfaces.ThetestforCalciumHardnessisameasureofhow“hard”or“soft”thewateristesting.“Hard”watercanhavehighlevelsofcalciumandmagnesium.Iftheselevelsaretoohighthewaterbecomessaturatedandwillleavecalciumcarbonatescaledeposits(a“white-ish,”crystallizedroughspot)onanysurfaceinsidethepool.Ifthelevelsaretoolow,thewaterbecomes“soft”andwillcorrodesurfacesinsidethepool.UseTSPorHydroquest100tolowerCalciumHardnesslevelsthataretoohighoraddwatertothepoolwhichhasalowercalciumhardnesscontent.Levelswhicharetoolowrequiretheadditionofcalciumchloride.

Total Dissolved Solids (TDS):AddingsalttopoolwaterwillraisetheTDSlevel.Whilethisdoesnotadverselyaffectthepoolwaterchemistryorclarity,thepoolwaterprofessionaltestingforTDSmustbemadeawaresalthasbeenaddedtotheIntelliChlorsystem.TheindividualperformingtheTDStestmaythensubtractthesalinityleveltoarriveataTDSlevelthatwouldbecompatibletoaTDSreadingforanon-saltwaterpool.

Total Alkalinity: APSP’srecommendedidealrangefortotalalkalinityis80to120ppmfor“gunite”andconcretepoolsand125-170ppmforpainted,vinyl,andfiberglasspools.Testlevelsweeklyandadjustaccordingtoyourpoolprofessional’srecommendations.AlkalinitycanbedescribedasabufferthatkeepspHinorder.pHdependsontheabilityofthealkalinityinthewatertowithstandthechangesinpH.Ifthealkalinityistoohigh,addingacid(similartopH)lowersthelevel.Addingabase(e.gsodiumbicarbonate)whenalkalinityislow,raisesthelevel.Thelevelofalkalinityinthewaterisameasurementofallcarbonates,bicarbonates,hydroxides,andotheralkalinesubstancesfoundinthepoolwater.

Cyanuric Acid:Cyanuricacidisneededinoutdoorpoolstohelptostabilizeandmaintainproperlevelsofchlorine.90%ofunstabilizedchlorineisdestroyedbytheUVradiationfromthesunwithintwohours.CyanuricacidstabilizeschlorineinwaterfromUVdegradation.WhenusingtheIntelliChlor(SC),thecyanuricacidlevelshouldbemaintainedbetween30-50ppm(50ppmmaximum).

Page 49: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

41

Settings Menu: Heat Pump COM (UltraTemp® Heat Pump)

Heat Pump Com screenFromtheHeatPumpComscreenyoucanviewthecurrentUltraTemp®HeatPumpoperationstatus,andsettheunittooperatewithforheatingonly,coolingonly,orbothheatingandcoolingiftheunitisreversible.ConnectionfromUltraTempHeatPumpisviatheCOMPORTontheEasyTouchPL4/PSL4ControlSystemmaincircuitboard.Seepage69forUltraTempHeatPumptoEasyTouchPL4/PSL4ControlSystemCOMportwiringinformation.TheUltraTempHeatPumpmustbesettodefaultADDRESS1.OneUltraTempHeatPumpunitcanbeconnectedtoEasyTouchPL4/PSL4ControlSystem.

Note: Once the UltraTemp Heat Pump is enabled, use the Left and Right arrow buttons to adjust the UltraTemp Heat Pump temperature and cooling.

Heat Pump Com

ToaccessHeatPumpCom(UltraTempHeatPump)settingsmenu:

MENUsSETTINGSsHEAT PUMP COMwSETTINGS

Right button: Accessthe“Settings”menu. Up/Down buttons: SelectYesorNotoenableordisableUltraTemp. Right button: Movetothe“Heating”setting. Up/Down buttons: SelectYesorNotouseforheating. Right button: Movetothe“Cooling”setting. Up/Down buttons: SelectYesorNotouseforcoolingonlyoriftheunitisreversibleselectbothheatingandcooling.

PresstheMenu buttontosavethesettingsandtoreturntotheHeatPumpComSettingsandStatusmenuoptions. PresstheMenu buttonthreetimestoreturntothemainscreen.

ToaccessHeatPumpCom(UltraTempHeatPump)Statusmenu:

MENUsSETTINGSsHEAT PUMP COMwSTATUS Right button: ToviewthecurrentUltraTempstatus. PresstheMenu buttontoreturntothemainscreen.

Heat Pump Com Enable : Yes Heating : YesCooling : Yes

Settings Status

Status [ OP NORMAL ] <MENU> = EXIT

Settings Status

Page 50: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

42

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Settings Menu: Circuit NamesLabeling Circuit Buttons in the EasyTouch® PL4/PSL4 Control System Power Center

EasyTouchPL4/PSL4ControlSystemisfactoryconfiguredtodisplayeachoutputcircuitbyitsgenericname(e.g.AUX1,AUX2,AUX3).Thesegenericcircuitauxiliarynamescanbeassignedanewnameswhicharemoredescriptiveoftheequipmentbeingcontrolled.Thismakesitmucheasiertooperateallofthepool,spaandlightingequipmentwithouthavingtomemorizewhateachoutputcontrols.

Forcircuitidentification,adhesivebackedcircuitnamelabelsareprovidedforplacementnexttoeachauxiliarycontrolpanelbutton.Usethewrittenlistofcircuitnames(buttons)thatyoumadewhilesettingupthePowerCenter.Identifywhatyoulabeledcircuitbutton1,button2etc.ThecircuitnamesyouassignshouldmatchthelabelsyouputonthePowerCentercontrolpanelbuttonsand/ortheoptionalIndoorControlPanelbuttons.Notethatexamplesshownbelowusethefactorysetgenericoutputnamesdisplayedinthecontrolsystemcontrolpanelmenus.

Circuit Names

Toassigncircuitnames:

MENUsSETTINGSsCIRCUIT NAMESwCIRCUIT NAMES

Up/Down buttons: Selectthecircuitnumber1/7.PresstheUp buttontwotimestoselectAUX1.The generic circuits names are: Spa (1/7), Pool (2/7), Aux 1-3 (3-5/7), Ft 1-2 (6-7/7). Thecircuitnumber1/7correspondstoitsassignedcircuitname.Thisnamecanbechangedtosuitthefunction. Right button: Movetosystempresetcircuitnamesanduserdefinedcustomcircuitnames. Up/Down buttons: Scrollthroughthelistofalphabeticalprogrammednames.Ifyoucannotfindanametomatchyourcircuit,youcancreateyourowncustomname (seepage48).Repeatforallthecircuitbuttonsthatyouwishtoassignnamesto.Foracompletelistofsystemcircuitnames,seepage43.

PresstheMenubuttontosavethesettingsandtoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Note: After a generic circuit name is changed and saved, the new name is displayed in the menu settings. You can view the default generic circuit names in the menu settings before they were changed by enabling “Cir Names.” Refer to “Diagnostics: Cir Names (Off),” on page 59.

Hi-Temp/Lo-Temp Controls for Single Body System

ForanEasyTouchPL4ControlSystemsinglebodysystem,youhavetheoptiontocontrolyourpoolandspatemperaturesettingsusingtheValves(V)buttonortheSpa(Hi-Temp)andPool(Lo-Temp)buttonontheoptionalIndoorControlPanel.ChangethecircuitnameSPA to HI-TEMPandPOOL to LO-TEMPsothatthedisplayshowsthecorrecttemperaturecontrolsforyoursinglebodysystem.

Circuit Names Circuit #: 1/7 Circuit : SPA [SPA JET ]

Page 51: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

43

EasyTouch® PL4/PSL4 Control System Circuit Names

AERATORAIRBLOWERAUX1AUX2AUX3BACKWASHBACKLIGHTBBQLIGHTBEACHLIGHTBOOSTERPUMPBUGLIGHTCABANALTSCHEM.FEEDERCHLORINATORCLEANERCOLORWHEELDECKLIGHTDRAINLINEDRIVELIGHTEDGEPUMPENTRYLIGHTFANFIBEROPTICFIBERWORKSFILLLINEFLOORCLNRFOGGERFOUNTAINFOUNTAIN1FOUNTAIN2FOUNTAIN3FOUNTAINSFRONTLIGHTGARDENLTSGAZEBOLTSHIGHSPEEDHI-TEMPHOUSELIGHTJETSLIGHTSLOWSPEEDLO-TEMP

Custom Circuit Names(11charactersmaximum) USERNAME-01 ____________________

USERNAME-02 ____________________

USERNAME-03 ____________________

USERNAME-04 ____________________

USERNAME-05 ____________________

USERNAME-06 ____________________

USERNAME-07 ____________________

USERNAME-08 ____________________

USERNAME-09 ____________________

USERNAME-10 ____________________

MALIBULTSMISTMUSICNOTUSEDOZONATORPATHLIGHTS PATIOLTS PERIMETERL PG2000 PONDLIGHT POOLPUMP POOL POOLHIGHPOOLLIGHT POOLLOW POOLSAM POOLSAM1 POOLSAM2 POOLSAM3SECURITYLTSLIDESOLARSPASPAHIGHSPALIGHTSPALOWSPASALSPASAMSPAWTRFLLSPILLWAYSPRINKLERSSTREAMSTATUELTSWIMJETSWTRFEATUREWTRFEATLTWATERFALLWATERFALL1WATERFALL2WATERFALL3WHIRLPOOLWTRFLLGHTYARDLIGHT FEATURE1 FEATURE2 FEATURE3 FEATURE4FEATURE5 FEATURE6 FEATURE7 FEATURE8

Page 52: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

44

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Settings Menu: Circuit Functions

Assigning Circuit FunctionsFromthe“CircuitFunctions”menuyoucanassignspeciallogictothecleanerpump,spaspillway,lightsandMagicStream®Laminarcircuits.Forexample,whensettingupanautomaticpoolcleanerpump,youwouldassignthecircuitfunction“MASTERCLEANER.”Withthis“Cleaner”logicthecleanerpumpwouldforcethefilterpumpon,andthecleanerpumpwouldstartafteradelayoffiveminutes.Thecleanerpumpwouldautomaticallyshutoffwheneverthespaand/orsolarisswitchedon.

Freeze ProtectionFreezeprotectionswitchesonacircuitiftheoutsideairtemperaturesensordetectsthetemperatureisgettingclosetofreezing(below35°F(40°C)).Thesystemwillswitchonallcircuitsthathavebeenassignedfreezeprotection,andrunsthecircuitsfor15minutestostopthepipesfromfreezing.Thisisespeciallyimportantifthereisapoolandspacombination.Iffreezeprotectionissettoboththespaandpoolcircuits,thefilterpumpswitchesonandthepoolandspavalvesalternateevery15minutestokeepthewatermovinginboththepoolandspa.Thisprocesscontinuesuntilthefreezeconditionisover.

Circuit Functions

Toassignacircuitfunctionandfreezeprotection:

MENUsSETTINGSsCIRCUIT FUNC.wCIRCUIT/FUNC.

Up/Down buttons: Choosethecircuitname(displayedonthesecondline).Thegenericcircuitsnamesare:SPA [MASTER SPA - Freeze protection on by default], POOL [MASTER POOL - Freeze protection on by default], AUX 1-3 FEATURE 1-2. Right button: Movetothe“CircuitFunction”settingtoselectthecircuitfunctionfortheselectcircuitnamedisplayedonthelineabove. Up/Down buttons: Selectthecircuitfunction.Thisisthecircuitthatyouwishtoassignthefunctionlogicto.For a complete list of preset circuit functions, see “Preset Circuit Functions,” on page 42. Right button: MovetoFreezeProtectionsetting. Up/Down buttons: SelectYesorNotoassignfreezeprotectiontothiscircuit.If“Yes”isselected,thecircuitwillswitchoniftheairtemperaturedropsto35°F. Note: for the POOL circuit the filter pump will have freeze protection. For the SPA circuit the filter pump will run and the pool/spa valves will switch between pool and spa at 15 minutes intervals throughout the freeze condition. For the MASTER CLEANER circuit freeze protection is generally not needed for pool cleaner pumps since they get water flow from the filter pump. Just make sure that POOL has freeze protection.

PresstheMenubuttontosavethesettingsandtoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Circuit/Func.: [SPA ] [Master Spa ] Freeze: Yes

Circuit/Func.: [AUX 1 ] [LIGHT ] Freeze: No

Page 53: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

45

Preset Circuit Functions

Generic No special Logic. Simple On/Off control of a circuit with all the programmablecapabilities.

Master Spa Works with automatic pool cleaner pumps or cleaner valve actuator. It does thefollowing:

- Forces the filter pump on 5 minutes before the cleaner pump switches on.

- Switch the cleaner off when the spa is on.

- Switch the cleaner off for 5 minutes when the solar heating begins.

Master Pool Works with automatic pool cleaner pumps or cleaner valve actuator. It does thefollowing:

- Forces the filter pump on 5 minutes before the cleaner pump switches on.

- Switch the cleaner off when the spa is on.

- Switch the cleaner off for 5 minutes when the solar heating begins.

Master Cleaner Works with automatic pool cleaner pumps or cleaner valve actuator. It does thefollowing:

- Forces the filter pump on 5 minutes before the cleaner pump switches on.

- Switch the cleaner off when the spa is on.

- Switch the cleaner off for 5 minutes when the solar heating begins.

Light Allows special lighting features to work, such as ALL lights on or ALL lights off.

SAM Light Activates special color lighting programs on other screens on the Indoor Control Panelwhen used with SAM pool lights. For example, you can have ALL lights on or ALLlights off.

SAL Light Activates special color lighting programs on other screens on the Indoor Control Panelwhen used with SAL spa lights. For example, you can have ALL lights on or ALL lightsoff.

Photon Generator Photon Generator® light source allows Pentair Fiberworks fiber optic bulb be operatedby the Lights menu features Sync, Rotate, ALL ON and ALL OFF when used with SAMand SAL lighting.

Color Wheel Activates special color lighting programs on other screens on the Indoor Control Panelwhen used with Pentair Fiberworks. For example, you can have ALL lights on or ALLlights off.

Spillway For pool/spa combinations where the spa is raised above the pool. This setting movesthe return valve so that the filter pump pulls the water from the pool and returns it tothe spa, creating a water fall effect. Automatic pool cleaners are turned off when thisfeature is turned on.

Floor Cleaner This setting moves a 3-way valve every 20 minutes alternating flow between 2 cleanersystem valves that feed the pop-up heads.

IntelliBrite Activate an Intellibrite LED light.

MagicStream Activate a MagicStream laminar.

Page 54: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

46

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Settings Menu: Custom NamesTherearenearly100circuitnamesavailabletochoosefrom.Ifyoucannotfindonetofityourapplicationyoucancreateupto10customnames.Eachnamecanbeupto11alphanumericcharacters.Afteracustomnameissaved,itisthenavailableforselectionintheSchedules,2-SpeedPump,iS4andQuickTouchControllermenus.

Custom Name

Toassignacustomcircuitname:

MENUsSETTINGSsCIRCUIT NAMESwCUSTOM NAMES

Up/Down buttons: Selectacustomcircuitnamenumber(1-10).Youcancreateupto10customcircuitnames. Right button: Movetocustomcircuitnamesetting. Up/Down/Right buttons: Enterthecustomcircuitname(11charactersmaximum).

PresstheMenubuttontosavethesettingsandtoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Settings Menu: ValvesThisfeatureletsyouassignacircuittoValveAorB.TheEasyTouchPL4/PSL4ControlSystemcandrivetwoauxiliaryvalveactuators(AandB)forapplicationssuchassolarheatingandwaterfeatures.ByassigningAUXcircuitstocontrolvalveactuators,youcanconserveauxiliarycircuitsforhighvoltagerelaysforcontrollingpumpsandlights.

Valve A:ResidesontheEasyTouchPL4/PSL4ControlSystemmaincircuitboard.Ifsolarheatingissetupandisnotconfiguredasaheatpump,thenValveAisdedicatedforcontrollingthesolarheatingvalveactuator.Solarisenabledinthe“Solar”menu.TheValveAselectionwilldisplay“USEDSOLAR.”Valve B:Residesonthemaincircuitboard.Canbeconfiguredtobecontrolledbyanycircuit.

Valves

ToassignacircuittoValveAandValveB:MENUsSETTINGSsVALVESwSETUP VALVES

Up/Down buttons: SelectacircuittoassigntoVALVE A.Thegenericcircuitnamesare:Thegenericcircuitsnamesare:NONE,SPA,POOL,AUX1-3 FEATURE1-2,andHEATER.UsetheSolarbuttontoswitchthecircuitonandoff(seepage5).SelectingNONEdoesnotassignacircuit. Right button: MovetoValveBsetting. Up/Down buttons: SelectacircuittoassigntoValveB.Seeaboveforthegenericcircuitsnames. PresstheMenubuttontosavethesettingsandtoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Cstm Name 1/10 [USERNAME-01]

Set Valves A: [CLEANER ] B: [FOUNTAIN ]

Set Valves A: [USED SOLAR] B: [FEATURE 1 ]

Page 55: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

47

Settings Menu: 2-Speed PumpEquipmentcircuitsselectedinthismenuwillautomaticallyswitchatwo-speedfilterpumptohighspeedwhenthesecircuitsareon.Ifatwo-speedpumpisassignedtosolar,acleanerorapump,whenactivatedthepumpwillautomaticallyrunforfiveminutesinhighspeedthenswitchtolowspeed.Forexample,whenon,thefilterpumpwillswitchtohighspeedwhenevertheJETSorCLEANERison.Theremustbeatwo-speedrelayinstalledintheEasyTouchPL4/PSL4ControlSystemPowerCenterinorderforthe“2-SpeedPump”menusettingstofunction.

2-Speed Pump

Toconfigureatwo-speedpumptoacircuit:

MENUsSETTINGSs2-SPEED PUMPw2-SPEED PUMP

Settings Menu: SolarUsethesolarsettingstosetupsolarorconfiguresolarasaheatpump:Setting Up Solar Control:Ensurethatthesolartemperaturesensorisinstalled.

About Installing Solar Heating: First,installthesolarsensoratthecollectorsandconnecttotheEasyTouchPL4/PSL4ControlSystemPowerCenter.IfHEATPUMPisselectedandisbeingusedinplaceofasolarheatingsystem,installSolarsensorneartheEasyTouchPL4/PSL4ControlSystemPowerCenter.ConnectthewirestotheSOLARscrewterminalsaccordingtothewiringdiagramonpage64.Plugthesolarvalveactuatorcableintothree-pinsocketmarkedVLVAontheEasyTouchPL4/PSL4ControlSystemmaincircuitboard.Ifasolarboosterpumpisbeinginstalled,connectthepumptoapowerrelayandplugalowvoltagecablefromrelayintothetwo-pinsocketmarkedSOLARontheEasyTouchPL4/PSL4ControlSystemmaincircuitboard.

To access the Solar menu:MENUsSETTINGwSOLARwSOLAR

Up/Down buttons: Selectacircuitthatwillswitchthefilterpumptohighspeed.Youcansetuptofourcircuitstouseatwo-speedpump(1/4,2/4,3/4,4/4). Right button: Movetoassignacircuitsetting. Up/Down buttons:Selectthecircuittoassigntoatwo-speedpump.Thegenericcircuitsnamesare:NONE, SPA, POOL, AUX 1-3, FEATURE 1-2, SOLAR, HEATER, POOL HEATER, SPA HEATER and FREEZE.SelectingNONEdoesnotassignacircuit. Note: You can use a Feature circuit to change a 2-Speed pump to high speed. Right button: Assignthenextcircuit(2/4). Up/Down buttons: Selectthefirstdigitforthecircuitnumber(1/4,2/4,3/4,4/4). Right button: Movetocircuitsetting. Up/Down buttons: Selectthenextcircuit.WhenfinishedpresstheMenubutton.

Solar: Press the Up/Downbutton to select which solar screen to view. Press the Right

PresstheUp/Down buttontoselectwhichsolarscreentoview.PresstheRight buttontoselectthesettingandtheUp/Down buttontochangeasettingorvalue. Screen (1/3): ENABLE SOLAR:Isthepoolusingsolarheat?SelectYesorNotoenablesolarheat.Todisplaythesolarselectionasaheatsourceinthemainscreen,selectYes.

2-Speed Pmp 1/4 Circuit: [SPA HEATER ]

Solar 1/3 Enable: Yes Heat Pump: No

Solar 2/3 Enable Freeze Enable: Yes/ No

Solar 3/3 Temperature Diff Start: 6° Run : 4°

Page 56: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

48

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Settings Menu: Delays (Spa/Pool (Heater Cool-Down) and Delays For Valves) Setupwhichfunctions(pool/spa,andvalves)toassignthedelayfeature.Delayscanbeassignedtothefollowingequipment.See"Delays"belowfordelaycooldownanddelayforvalvesinformation.

• Heater Cool-Down Delay Cancel:ShutsFilterPumpoffimmediately.• 2-Speed Filter Pump five-minute START on HIGH SPEED Delay Cancel:Shiftspumptolow

speed.• Automatic Pool Cleaner START Delay:StartsCleanerPumpimmediately,withoutnormaldelayin

whichthefilterpumpfirstrunsfor5minutes.• Automatic Pool Cleaner SOLAR Delay:AllowsCleanerPumptoruneventhoughsolardelayhas

shutitofffor5minutes.Someheatersrequireacooldowncyclebeforebeingswitchedoff.Thiscanbesetuptorunthefilterpumpanadditionaltenminutestodissipateresidualheatbuiltupinsidetheheatercombustionchamber.Youcanalsocancelthedelayfeature.Forinformationaboutusingthecanceldelayfeature,referto“DelayCancel” onpage31.

PresstheUp/Down buttonstoselectYES to enable COOLDOWN delaysforthepoolandspacircuits.SelectYEStousedelaysforvalves.PresstheMenubuttontosaveandtoreturntotheSettingsmenuoptions.

HEAT PUMP: Isaheatpumpbeingusedforsolarheat?SelectYesorNotoenablesolarasaheatpump.Heat Pump Control instead of Solar: SelectYESifaheatpumpisbeingusedinplaceofasolarheatingsystem.IfSolarissettoheatpump,Valve Aisfreeforothercircuits. Right button: Select2of3(2/3)toaccessthefreezeandnightcoolingfeatures. Screen (2/3): ENABLE FREEZE: Enablefreezeprotectionwhenusingsolarheat.SelectYesorNotoenablefreezesolarprotection. Screen (3/3): Solar temperature differential start up and run settings. Start:Setthetemperaturedifferentialtostartheatingfrom3°to9°.Forexample,if“Start”issetto3°,thisensuresthatthetemperaturehastodeviateby3°atleasttothespecifiedsetpointtemperature(intheHeatmenu,onpage25)beforeitswitcheson.Oncethesolarcomesonitwillstartconvergingasitisheating.Thisensuresthatitwillnotcontinuallybeswitchingonandoff. Run:Setthetemperaturedifferentialtostopheatingfrom2°to5°.Thissettingsetshowclosetothetargetsetpointtemperaturetoswitchoffsolarheat.

Delays

Toassignadelayfeature:

MENUsSETTINGsDELAYSwDELAYS

Delays Cool down:Thisfeaturekeepsthepumprunningfortenminutesaftertheheaterisswitchedofftocooldowntheheatersheaderandheatexchanger.Someheatermodelsrequirethiscooldownperiodordamagewilloccur.Thisissometimereferredtoasthe“FiremanSwitch.”forexample,Ifyouareinthespa,andyouswitchitoff.Thesystemwillreturnthevalvesto“Pool”modeposition.Ifthepoolisrunningacycle,ortheFiremanswitch(Spa/PoolDelay)isenabled,colderwaterfromthepoolwouldbepumpedintothespaasthevalvesturn.Note:Ifthepoolisnotrunningacycle,andthefiremanswitchisnotenabled,thepumpstopsandnopoolwaterwouldbepumpedintothespaasthevalvesturnbacktopool.

Delays For Valves:Thisfeaturecreatesa30secondPUMPOFF(forced)periodanytimethevalvesrotate.Eitherfrompooltospa,orspatopool.Whenyouswitchthespaoff,evenifthepoolisrunningacycleorthefiremanswitchisenabled,itstopsthepumpfor30secondswhilethevalvesturn,socolderwaterfromthepoolwillnotenterthespa.Thisfeaturepreventscoldwaterenteringthespawhenyoustartthespa,solessheatingisneeded.ItalsostopsthepumpwhenthesystemischangingfrompooltospaorbackagaininFreezemode.

Delays Cooldown: No Valves: No

Page 57: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

49

Settings Menu: F° / C° (Fahrenheit/Celsius)Thetemperaturesettingsforthewater,solarandaircanbedisplayedineitherFahrenheitorCelsius.

F° / C°

Tochangethetemperatureunits:

MENUsSETTINGsF°/C°wDF°/C°

Up/Down buttons: SelecteitherFahrenheitorCelsius.PresstheMenubuttontosavethesettingsandtoreturntotheSettingsmenuoptions.PresstheMenu buttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Settings Menu: iS4 Spa-Side Remote ControllerYoucanspecifyanyiS4Spa-Sideremotebuttontocontroldifferentfunctionsbyassigningeachbuttontoaspecificcircuit.Forexample,youcanusetheiS4Spa-Sideremotetoactivatethespacirculationandforoperatingauxiliaryequipmentsuchasheater,lights,jetpump,airblower,waterfall,etc.).

Assign iS4

BeforeconfiguringtheiS4Spa-Sideremotecontrollerassignnamestothecircuits(seepage45).

ToassigniS4Spa-Sidebuttons:

MENUsSETTINGsIS4wASSIGN IS4

Up/Down buttons: SelectacircuittooneoftheiS4buttons.Youcansetuptofourcircuits(1/4,2/4,3/4,4/4). Right button: Movetothecircuitsetting. Up/Down buttons: ToconfigurethefirstbuttonontheiS4Spa-SideRemote,scrollthroughthecircuitnamesandfindthecircuitthatyouwouldliketoassigntothefirstbuttonontheiS4.Thegenericcircuitsare:NONE, SPA, POOL, AUX 1-3, FEATURE 1-2. Selecting“NONE”doesnotassignacircuit. Right button: Assignthenextcircuit(2/4). Up/Down buttons: Selectthefirstdigitforthecircuitnumber(1/4,2/4,3/4,4/4)andrepeattheprocedurefortheotherthreebuttons. PresstheMenubuttontosavethesettingsandtoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Note:TodisableorenabletheiS4Spa-Sideremote,seeSettingsMenu:SpaSide,”onpage56.

F° / C° FAHRENHEIT

Assign iS4 Circuit: 1/4 [AUX 1 ]

Page 58: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

50

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Settings Menu: QuickTouch® II (QT4) Wireless ControllerTheQuickTouch®II(QT4)WirelessControllerprovidesswitchingofuptofourcircuits.Forexample,youcanusetheQT4wirelesscontrollertoactivatethespacirculation,andforoperatingthreeauxiliarypiecesofequipment(suchas,lights,jetpump,airblower,waterfall,etc.).

EachofthefourfunctionsontheQT4wirelesscontrollerhasanonandanoffbutton.Toswitchacircuitonoroff,pressandholdtheappropriatebuttonforatleastafullsecond.

TheQT4wirelesscontrollerbuttonscanbeassignedtoanyavailablecircuit.However,theQT4wirelessremotehasthefollowingpresetcircuitsassignedtothefourbuttons:

• Spabuttonactivatesthespa circuit.

• AbuttonactivatesAuxiliary 1circuit.

• BbuttonactivatesAuxiliary 2circuit.

• CbuttonactivatesAuxiliary 3circuit.

Assign QT4 II Remote

ToassigncircuitstotheQuickTouchIIWirelessControllerbuttons:

MENUsSETTINGsQUICKTOUCHwASSIGN QT4

Up/Down buttons: SelectacircuittoassigntooneoftheQuickTouchwirelessremotebuttons.Youcansetuptofourcircuits(1/4,2/4,3/4,4/4). Right button: Movetothecircuitsetting. Up/Down buttons: Toconfigurethefirstbutton(1/4)ontheQuickTouchwirelesscontroller.Usethesebuttonstoscrollthroughthecircuitnamesandfindthecircuitthatyouwouldliketoassigntothefirstbutton.Thegenericcircuitsare:NONE, SPA, POOL, AUX 1-3, FEATURE 1-2. Selecting“None”doesnotassignacircuit.

Right button: Assignthenextcircuit(2/4). Up/Down buttons: Selectthefirstdigitforthecircuitnumber(1/4,2/4,3/4,4/4),thenrepeattheprocedurefortheotherthreebuttons. PresstheMenubuttontosavethesettingsandtoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Assign QT4 Circuit: 1/4 [SPA ]

Page 59: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

51

Settings Menu: Man Heat (Off/On)Bydefaultmanualheat(ManHeat)issetto“On,”whichallowsyourspatobegintoheatwheneveritismanuallyswitchedon,(bypressingtheValves (V)buttonandFilter Pump (F)buttonontheoutdoorcontrolpanelortheSpabuttonontheIndoorControlPanel),eveniftheHeatmenusettingissetto“OFF”(seepage30).YourspawillalsobegintoheatwhenswitchedonbytheiS4Spa-Sideremote.Thisfeatureallowsyoutoprogramyourspatofilterdailywiththeheatersettooff,andthenbereadytoheatwhenevertheSpabuttonispressedmanually.

Man HeatToenableordisablespamanualheatwhenswitchedonmanually:

MENUsSETTINGsMAN HEAT (ON/OFF)Right button: SelectOfftodisableorOntoautomaticallybeginspaheatingwheneverthespaisswitchedonmanually. PresstheMenubuttontosavethesettingsandtoreturntothemainscreen.

Settings Menu: CalibrationTheEasyTouchPL4/PSL4ControlSystemincludestwotemperaturesensors(10kΩ)forwaterandambientairtemperature.Youcanalsoaddanadditionalsensorforcontrollingsolarheatingsystems.Generally,thesesensorsareaccurateandyoudonothavetocalibratethem.However,longplumbingrunsandwaterfeaturescancausetemperaturesatabodyofwatertobedifferentfromthetemperaturesensorreading.Youcanmanuallyrecalibratethesensorstoadjustforthis.Youonlyneedtocalibrateonebodyofwater,sincethetemperaturesensoriscommontoboththepoolandspa.Thesystemmustbein“Service”modetocalibratesensors.

Calibration

Beforeyoustart,youneedanaccurateallweatherthermometer.Ifyouarecalibratingtheairsensor,waituntilthesensorisnotindirectsunlight.Fortheairtemperaturesensor,makesurethatthesensorislocatedintheshadeforaccuratereadings.

Tocalibratethewater,airandsolartemperaturesensors:

MENUsSETTINGsCALIBRATIONwCALIBRATION

1. PresstheModebuttononthecontrolpaneltoplacethesystemin“Service”manualmode.

2. PresstheFilter Pump (F) buttontoswitchonthepool/spafilterpump.

3. Placethethermometerinthespaorpoolwater.Takeanaccuratetemperaturereading.Whencalibratingtheairsensor,placethethermometernexttotheairsensor.TheairsensorisnormallylocatednearorundertheEasyTouchPL4/PSL4ControlSystemPowerCenterenclosure,notinsidetheenclosure.Takeanaccuratetemperaturereadingintheshade.

4. UsetheUporDown buttonstoraiseorlowerthewatertemperaturetomatchthecorrespondingthermometertemperaturereading.

5. Aftercalibratingthewatersensor,usetheRightbuttontomovetothe“AIR”settingandrepeatstep4andrepeattheprocedureforthesolarsensor.Ensurethatthesolarsensorisinthesunforaccuratereadings.

6. Aftercalibratingallthesensors,pressthe MenubuttontosavethesettingsandtoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

QuickTouch Man Heat [On]Calibration

Calibration Water: 70°F Air: 80°F Solar: 90°F

Page 60: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

52

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Settings Menu: Set PasswordIfrequired,thepasswordfeatureallowsyoutopasswordprotecttheEasyTouchPL4/PSL4ControlSystemcontrolpanel.Toaccessapasswordprotectedcontrolpanel,youmustenterthecorrectfourdigitpasswordbeforeaccessisgranted.

PasswordToenablethepasswordprotectfeature:

MENUsSETTINGsSET PASSWORD Up/Down button: Selectthepasswordfirst digit(0-9)ofthefourdigitpassword.

Right button: Selectthenextpassworddigit.Repeattheprevioussteptoentereachofthepassworddigits.

Right button: Afteryouarefinishedenteringthefourpassworddigits,presstheRightbuttontoenablethepasswordfeature.

Up/Down button: SelectYesenablethepasswordfeature.

PresstheMenubuttonthreetimestosavethesettingsandtoreturntothemainscreen.

Note:Ifthepasswordfeatureisenabled,thecurrentfourdigitpasswordcanbeviewedfromtheEasyTouchPL4/PSL4outdoorcontrolpanelinthe“SetPassword”setting.

Settings Menu: Erase EEPROM (Erase System Memory)EasyTouch®PL4/PSL4ControlSystemconfigurationdataisstoredandretainedin“Flash”memoryinanEEPROMlocatedonthecontrolpanelmaincircuitboard,andoptionalIndoorControlPanel.TheEasyTouchPL4/PSL4ControlSystemusersystemconfigurationdatacanbeerasedtorestorethefactorydefaultssettings.Systeminformationautomaticallydownloadsfromprogrammedcomponentstonon-programmedcomponentsincaseofaccidentalmemorylossandtoeaseboardreplacement.Anyoptionalcontrollers(iS4andQuickTouch®IIQT4WirelessController)thatwereconfiguredneedtobereconfigured.

Erase EEPROM

ThefollowingproceduredescribeshowtoerasethesystemmemoryfromeitherthemainEasyTouchPL4/PSL4ControlSystemcontrolpanelortheEasyTouchPL4/PSL4ControlSystemIndoorControlPanel.

CAUTION: This procedure will erase all system settings. Any optional controllers will need to be reconfigured.

MENUsSETTINGsERASE EEPROMwERASE EEPROM Up/Down button: SelectYes.

Right button: Themessage“Erase EEPROM Are You Sure? No” isdisplayed. Up/Down button: SelectYes. Right button: Pressthisbuttontoerasesystemdataandrestorethefactorydefaults.Thedisplaywillgoblank,thenthemainscreenwillbedisplayed.

Set Password PW : [0000] Enable : No

Erase EEPROM Erase ALL? No (Yes)

Erase EEPROM Are You Sure? No (Yes)

AUTO HEATERSPA 85°F / 100°F AIR 70°F MON 09:30 AM

Page 61: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

53

EASYTOUCH PL4/PSL4 CONTROL SYSTEM WIRELESS CONTROLLER:

Settings Menu: BacklightUsethebacklight“OnTime”optiontosetthedurationthatthebacklightwillstayon.The“Brightness”settingallowsyoutosetthebacklightbrightness.Theseoptionscanhelptoreducepowerconsumptionandextendbatterylife.TheBacklightoptionsare:

• On Time:Backlightwillstayonfor60seconds,30seconds,fiveminutes,or“Backlight”featureisoff.Thedefaultsettingis30seconds.

• Brightness:Backlightbrightnesscanbesettolow,mediumorhigh.Thedefaultsettingismedium. Backlight

Tosetthebacklightdurationandbrightness:

MENUsSETTINGsBACKLIGHT Up/Down buttons: Select5 S, 15 S, 30 S, 60 S, 5 MorOFFforthebacklighttostayon. Right button: SelectLOW, MED or HI forthebacklightbrightnesssetting. PresstheBackbuttontosavethesettingsandtoreturntothepreviousscreen.

Settings Menu: Wireless AddrUsethisfeaturetoassigntheEasyTouch®PL4/PSL4ControlSystemWirelessControllerauniquecommunicationaddresstoallowthewirelessdevicetooperatewiththeEasyTouchPL4/PSL4ControlSystemoutdoorcontrolpanel(seepage64).

Wireless Addr

TosearchandlockontotheEasyTouchPL4/PSL4ControlSystemwirelesscontroller:

MENUsSETTINGsWIRELESS ADDRwPress Right Arrow button

Address Wireless Sending Address.. <MENU>

Address Wireless Scanning ...

BACKLIGHT OPTIONS

On Time: 30 S Brightness: MED

Right button: PressthisbuttontoautomaticallysearchandlockontotheWirelessControllerwithinrangeofthetransceiverantenna. FormoreinformationabouttheWirelessController,seepage70

PresstheMenubuttontosavethesettingsandtoreturntotheSettingsmenuselections.

Important Note:1. Afteryoupluginatransceiverorpoweruptheunit,waitatleast60secondsbeforeaddressingtheunit.2. Ifthewirelessunittimesoutandpoweroffbeforelockingontheaddress,settheautopowerofftimeto

5minutesthenstarttheaddressing.Remembertosetitbackto1minuteafteritisworkingorbatterylifeisgreatlydecreased.

3. Ifyouareworkingwithmultiplesetsoftransceiversandhandheldsmakesureyoukeepthemseparatedintosets.

Page 62: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

54

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

WIRELESS CONTROLLER: Settings Menu: Power SaveThisoptionsetsthetimetheEasyTouch®PL4/PSL4WirelessControllerwillshutdownifthereisnocontrolpanelactivity.Usethepowersaveoptionstoreducepowerconsumptionandextendbatterylife.Theoptionsare:

• Power save:Setthepowersavetimeto15,30,or60seconds,orfiveminutesbeforetheunitshutsdown.Thedefaulttimeis60seconds.

Note: If the unit is not used for 60 (default) seconds the power save function switches off the unit. To switch the unit on, press the “POWER ON” button (see page 10).

Idle Time

TosettheidletimefortheEasyTouchPL4/PSL4WirelessController:

MENUsSETTINGsPOWER SAVE

Right or Up/Down buttons: Select30 S, 60 Sor5 M. PresstheBackbuttontosavethesettingsandtoreturntothepreviousscreen.

Spa Side [Off/On]EnableordisabletheiS4SpaSideremote.Thisfeatureisusefulforfamilieswithyoungchildrenorwhenyougoonvacation.ItallowsyoutoswitchofftheiS4SpaSideremoteatthecontrolpanelsothattheremotecannotbeused.

Spa Side

ToenableordisabletheiS4SpaSideremote:

MENUsSPA SIDE (ON/OFF)Right button: SelectOnorOfftoenableordisablethespasideremote. PresstheMenubuttontosavethesettingsandtoreturntothemainscreen.

Diagnostics Menu: Software RevDisplaysthecurrentsoftwarerevisionfortheEasyTouchControlSystemPL4/PSL4maincontrolpanelandtheoptionalindoorcontrolpanel.

MENUsDIAGNOSTICSsSOFTWARE REV

UIC: Displaysthecurrentsoftwarerevisionlevelfortheindoorcontrolpanel. UOC:Displaysthecurrentsoftwarerevisionlevelfortheoutdoorcontrolpanel. PresstheMenubuttontoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

POWER SAVE IDLE TIME: 60 S

Delay Cancel Schedules Settings Spa Side [On ]

Software Rev UIC: 2.130 UOC: 2.130

Page 63: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

55

Diagnostics Menu: Self TestTeststhecontrolpanelLCDandbuttons.Followtheon-screenpromptstoperformthetests.

MENUsDIAGNOSTICSsSELF TESTNote: If the Indoor Control Panel is connected to the EasyTouch PL4/PSL4 Control System outdoor control panel, select “LINK CLOSED” in the UART test to abort the UART test. This allows the test to complete with and display PASSED.

PresstheRightbuttontodisplaythecurrentsoftwareandbootloaderrevisionlevelsfortheoutdoorcontrolpanel. PresstheRightbuttontostartthetest: PresstheRightbuttontostartthetest:

Display Test: PressanybuttontostarttheLCDtest.

Backlight Test:PresstheLeftthenRightbutton.

Contrast Test:Pressanybuttontocontinue.

LED Test:Pressanybuttontocontinue.AllofthebuttonLEDswillbetested.

Switch Test:Pressanybuttontocontinue.Asprompted,presstheappropriatebuttons.

UART Test:Select“LINKCLOSED”toabortthistestiftheoptionalIndoorControlPanelisconnectedtothesystemPowerCenter.

Status: Passed - Code 0: Afteryouhavecompletedthetest anerrorcodeisdisplayed.“Passed”isdisplayedifthetestwassuccessful.Forerrorcodedescriptions,see“SelfTestErrorCodes,”onpage59.

PresstheMenubuttontoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Diagnostics Menu: Bootloader RevDisplaysthecurrentbootloaderrevisionfortheindoorcontrolpanelandthemainEasyTouchPL4/PSL4ControlSystemcontrolpanel.

MENUsDIAGNOSTICSsBOOTLOADER REV

UIC: Displaysthecurrentbootloaderrevisionlevelfortheindoorcontrolpanel. UOC: Displaysthecurrentbootloaderrevisionlevelfortheoutdoorcontrolpanel. PresstheMenubuttontoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Backlight On <=Backlight On >=Backlight Off

Contrast: Press any button

LED Test

Switch Test Press any button

UART Test <=Link Closed >=Link Open

Press Any Button

Firmware VersionSoft: 2.130 Boot: 2.130Press Any Button

Bootloader Rev UIC: 1.02 UOC: 1.02

Page 64: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

56

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Chlorinator Salt Level:3200ppm Status: [OK-NO ERRORS]

Water Temperature

75° F

Diagnostics Menu: ChlorinatorDisplaysthecurrentIntelliChlor®SaltChlorineGeneratorsystemstatus.Formoreinformation,refertotheIntelliChlorSaltChlorineGeneratorUser’sGuide(P/N520589).

MENUsDIAGNOSTICSsCHLORINATOR

Menu: PressthisbuttontoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

SALT LEVEL: Displaysthecurrentsaltlevel.Valuesfrom0to12750ppmin50ppmincrements.IntelliChlorStatusmessages:

SUPER CHLORINATE: IntelliChlorisin“SuperChlorinationmode(seepage35fordetails)COM LINK ERROR: CheckcablefromIntelliChlortoEasyTouchPL4/PSL4ControlSystemmiancircuitboard.Check FLOW/PCB:CheckIntelliChlorelectrolyticcellcontroller.RefertoIntelliChlorUser’sGuidetroubleshootinginformation.LOW SALT: Addsalttopoolwater.Thewatersaltlevelisbetween2500ppmand2900ppm.TheIntelliChlorwillcontinuetoproducechlorineatareducedlevel.VERY LOW SALT: Notenoughsaltinpool.Thewatersaltlevelhasfallenbelow2500partspermillion(ppm).IntelliChlorwillnotproducechlorineuntiladditionalsaltisaddedmanually.HIGH CURRENT: CheckIntelliChlorelectrolyticcellcontroller.RefertoIntelliChlorUser’sGuidetroubleshootinginformation..CLEAN CELL!!:Cellhascalciumbuildupandrequirescleaning.RefertoIntelliChlorUser’sGuideforcleaninginstructions.LOW VOLTAGE: CheckIntelliChlorelectrolyticcellcontroller.RefertoIntelliChlorUser’sGuidetroubleshootinginformation.OK - NO ERRORS: IntelliChlorisinnormaloperatingmode.

Diagnostics Menu: Water TempDisplaysthecurrentwatertemperatureforthepoolandspa.

MENUsDIAGNOSTICSsWATER TEMP

PresstheMenubuttontoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Diagnostics Menu: Solar Temp

Displaysthecurrentsolartemperature.

MENUsDIAGNOSTICSsSOLAR TEMP

PresstheMenubuttontoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Solar Temperature

85° F

Page 65: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

57

Diagnostics Menu: Reset System ReinitializetheOutdoorControlPanel.ResettingtheOutdoorControlPanelwillnoteffectthesystemconfigurationsettings.

MENUsDIAGNOSTICSsRESET SYSTEM Right button:PresstheRightbuttontoresetsystem.ThemainscreenwillbedisplayedandcommunicationwillbeestablishedwiththeoptionalEasyTouchPL4/PSL4ControlSystemIndoorControlPanelifinstalled.

Diagnostics Menu: Flash UpdateUsethisfeaturetoupdatetheEasyTouchPL4/PSL4ControlSystemOutdoorControlPanelfirmware.TheEasyTouchPL4/PSL4ControlSystemmaincircuitboardmustbeconnectedtoapersonalcomputer(PC)inordertoupdatethefirmware.

MENUsDIAGNOSTICSsFLASH UPDATE

PresstheMenubuttontoexittheflashmode.

Diagnostics Menu: Air TempDisplaysthecurrentoutsideairtemperature.

MENUsDIAGNOSTICSsAIR TEMP

PresstheMenubuttontoreturntotheSettingsmenuoptions.Pressthebuttonagaintoreturntothemainmenuoptionsorpressagaintoreturntothemainscreen.

Diagnostics Menu: Cir Name: [Off/On] Thisfeatureisusefulifyouhaverenamedmanycircuitsandwanttoviewtheoriginalfactorydefaultcircuitnames.

MENUsDIAGNOSTICSsCIR NAMES (OFF) Toenable:

Right button: SelectOntoviewthefactorydefaultcircuitnames.

PresstheMenubuttontoexit.

Todisable:

Right button: SelectOfftodisablethefeature. PresstheMenubuttontoexit.

Air Temperature

72° F

Solar Temp Air Temp Disp codes Cir Names [Off]

Air Temp Disp codes Cir Names [Off] Reset System

Press MENU to exit

Page 66: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

58

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

EasyTouch® PL4/PSL4 Control System Wiring Diagram (Outdoor Control Panel)

Page 67: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

59

Section3 Troubleshooting

TroubleshootingUsethefollowingtroubleshootinginformationtohelpresolveproblemsthatmayoccurwhenusingtheEasyTouch®PL4/PSL4ControlSystem.Ifbyfollowingtherecommendedactionsyouarestillunabletoresolvetheproblems,pleasecontactTechnicalSupport(seepageii).

Frequently Asked Questions (FAQ)How do I setup a two-speed pump?

Atwo-speedpumpoperatesusingtworelaysandoneormorecircuits.Thefirstrelayturnsthepumponoroff.Assumingthisisafilterpump,thiscircuitiscontrolledbythepoolandspacircuitsoranyothercircuitthatmaybetiedtothefilterpump(suchascircuitswithfreezeprotection,etc.).Thesecondrelayswitchesthepumpfromlowspeedtohighspeed.Thedefaultconditionislowspeed.Uptofourcircuits(exceptforSpa/HiTemp)maybeassignedtotriggerthepumptohighspeed.Note:Thesecircuitsdonotswitchthepumpon.

Toconfigureatwo-speedpumprelay,referto“SettingsMenu:2-SpeedPump,”onpage47.Forrelaylocationandwiring(seepage58).The2-Speedpumprelayconnectorispluggedintothe2-SPDoutputontheEasyTouchPL4/PSL4ControlSystemmaincircuitboard.

How do I switch on solar heating?

Thesystemmustfirstbeconfiguredforsolarheating.Gotothe“Heat”menu(seepage30)andenable“Solar”astheheatsourceMENUsHEATsSOLARNote:Donotsetsolarasaheatpump.Thentheheatingmethodmustbeselectedforeachbodyofwater.

EasyTouch® PL4/PSL4 Control System Error Messages Error Messages

IfthesystemdetectsthatasensorisnotconnectedtotheEasyTouchPL4/PSL4ControlSystemPowerCenteroritisdefective,anerrormessageisdisplayedinthe“Diagnostics”menu.Thefollowingliststhesensorerrors.

Error Message Possible Cause Solution

AirErr(DisplaysontheMainScreen)

Airsensornot connectedtotheEasyTouchPL4/PSL4ControlSystemmaincircuitboard.

CheckthattheairsensorplugisconnectedtoJ21connectorontheEasyTouchPL4/PSL4ControlSystemmaincircuitboard.Checkthatthesensorwireisconnectedproperly.

AirTemperatureErr(Displaysinthe“Diagnostics”menu)

AirsensornotconnectedtotheEasyTouchPL4/PSL4ControlSystemmaincircuitboard.

CheckthattheairsensorplugisconnectedtoJ21connectorontheEasyTouchPL4/PSL4ControlSystemmaincircuitboard.

WaterTemperatureErr,displaysinthe“Diagnostics”menu)

WatersensornotconnectedtotheEasyTouchPL4/PSL4circuitboard.

CheckthatthewatersensorplugisconnectedtoJ21connectoronthemaincircuitboard.

SolarTemperatureErr,,displaysinthe“Diagnostics”menu)

SolarsensornotconnectedtotheEasyTouchPL4/PSL4circuitboard.

CheckthatthesolarsensorplugisconnectedtoJ21connectoronthemaincircuitboard.

Page 68: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

60

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Self Test Error Codes

The“SelfTest”featureisintendedforusebyservicepersonnel.Ifafterperformingacontrolpanelselftest(seepage55)therewerenoerrorsdetected,Code0isdisplayed,indicatingthattherewerenoproblemsandthetestwassuccessful.Ifaproblemisdetectedduringthetest,anerrorcodeisdisplayeduponcompletionofthetest.ForexampleCode3wouldindicateaproblemwiththeLEDsonthecontrolpanel.Ifmultipleerrorsaredetected,multiplecodenumbersaredisplayed.Forexample,Codes4,2,1,wouldindicateproblemsdetectedwiththebuttons,LEDs,andtheLCDbacklightonthecontrolpanel.

Thefollowingliststhecontrolpanelselftesterrorcodes.

Error Code Table

EasyTouch® PL4/PSL4 Control System Error Messages (Continued)

Error Code Description

Code0PASS-Thecontrolpanelhasnoproblems

Code1 LCDbacklight

Code2 LCDcontrast

Code3 LEDs

Code4 Switch(buttons)

Code5 UARTloopbacktest

Code6 Sensor/Relay/Valvestest

Page 69: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

61

Status Message Possible Cause Solution

OK-NOERRORSIntelliChlor(SC)normal operatingmode.

N/A

SUPERCHLORINATEIntelliChlor(SC)isin “SuperChlorination”modefor24hours.

IntelliChlor(SC)isin“SuperChlorinationmode (seepage38ordetails)

COMLINKERROR

IntelliChlorSC communicationerrorwithEasyTouchPL4/PSL4ControlSystemcircuitboard.

CheckcablefromIntelliChlorSCtoEasyTouchPL4/PSL4ControlSystemcircuitboard.

CHECKFLOW/PCBCheckIntelliChlor(SC)electrolyticcell.

RefertoIntelliChlor(SC)User’sGuidetroubleshooting information.

LOWSALT Addsalttopoolwater.

Thewatersaltlevelisbetween2500ppmand2900ppm.TheIntelliChlor(SC)willcontinuetoproducechlorineatareducedlevel.SeeIntelliChlorSCGUser’sGuidefordetails.

VERYLOWSALT Notenoughsaltinpool.

Thewatersaltlevelhasfallenbelow2500partspermillion(ppm).IntelliChlor(SC)willnotproducechlorineuntiladditionalsaltisaddedmanually.SeeIntelliChlor(SC)User’sGuidefordetails.

HIGHCURRENTCheckIntelliChlor(SC)electrolyticcell.

CheckIntelliChlorelectrolyticcellcontroller.RefertoIntelliChlor(SC)User’sGuidetroubleshooting information.

CLEANCELL!!Cellhascalciumbuildupandrequires cleaning.

Cellhascalciumbuildupandrequirescleaning.RefertoIntelliChlor(SC)User’sGuideforcleaning instructions.

LOWVOLTAGECheckIntelliChlor(SC)electrolyticcell.

RefertoIntelliChlor(SC)User’sGuidetroubleshootinginformation.

Maximum Programs Exceeded

The“MaximumProgramsExceeded”messagedisplaysinthe“Schedules”menuifyoutrytocreateanewprogramafterexceedingthefourprogramlimit.Tocreateanewprogramyoumustfirstdeleteanexistingprogram.Forinformationaboutdeletingaprogram,referto“ScheduleMenu”onpage32.

IntelliChlor Salt Chlorine Generator (SCG) Error Messages

TheIntelliChlorSaltChlorineGeneratorstatusanderrormessagesaredisplayedinthe“IntelliChlor”menu(seepage38).UsethefollowinginformationtoresolvetheIntelliChlorSaltChlorineGeneratorproblems.Toaccessthe“IntelliChlor”menu,pressMenu > Diagnostics > Chlorinator.

Page 70: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

62

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Problem: iS4failstooperate.

Symptom Possible Cause Solution

iS4Remotefailstooperateequipment.

iS4Remoteisdisabled. Seepage54toenabletheiS4.

DefectiveWiringVerifyiS4Remotesetup.EnsuretheiS4Remoteinquestionhastheexpectedcircuitassignments,andisnotassignedtounusedcircuits.

Incorrectconfigurationorbuttonsetup.

Seepage49tosetuptheiS4Remotebuttons.

DefectiveiS4Remote ReplacedefectiveiS4Remote

iS4failstooperateonlysomeoftheswitches,butothersworkfine.

DefectivewiringononeormoreiS4leads VerifywiringonmaincircuitboardandiS4.

Incorrectconfigurationorcircuittoswitch assignment.

Verifycircuitboardconnection.

System Problem Diagnosis Usethefollowinginformationtoresolvecontrolsystemproblems.

Problem: The control system works in Service Mode, but EasyTouch PL4/PSL4 Control System Indoor Control Panel fails to operate.

Symptom Possible Cause Solution

IndoorControlPanelhasnopower-(screen,blank,noLEDs,buttonsnotworking).

BadwiringrunfromOutdoorControlPanel/maincircuitboardinthePowerCenter.

Verifycableandensurenoconnectionsarebroken.Insomecasesawireisbrokenundertheinsulation.Thetwocenterwiresofthefourconductorcablearesuspect(GreenandYellow)

IndoorControlPanellightsup,butfailstooperatecorrectly.Theunitwillnotturnequipmenton/off,ormayturnsomeitemson,butnotoffandmaynotLEDsnearbuttonsoncontrolpanel.

DefectiveCable/wiring

Verifycableandensurenoconnectionsarebroken.Insomecasesawireisbrokenundertheinsulation.Thetwocenterwiresofthefourconductorcablearesuspect(GreenandYellow)

Page 71: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

63

Problem: TheQuickTouch®IIWirelessRemotewillnotwork,orwillnotworkdependably.

Symptom Possible Cause Solution

POWERLEDdoesnotlightontheReceiverboardlocatedintheplasticclamshell.

EasyTouchPL4/PSL4Control SystemPowerCenterdoesnothavepower

Ensurepowerisbeingsuppliedandthatthepowercenteroperatescorrectlywithoutthereceiverinstalled

DefectivecableorconnectiontothePowerCenter

Verifythefunctionoftheboardusingknowngoodcableset.Checkallwiring

DefectiveReceiverboardContactTechnicalSupport

COMMLINKLEDdoesnotlightorblink.InnormaloperationLEDwillblinkatleastevery2seconds

DefectivecableorconnectiontothePowerCenter

Verifythefunctionoftheboardusingknowngoodcableset

Defectivereceiverboard Replacereceiverboard

Addressswitchesareincor-rectlyconfigured

Verifythattheaddressswitchesonthetransmitterandhandheldreceiverboardarecorrectandmatch

Transmitterbatteryhasfailed

ReplaceTransmitterbatteryDefectiveTransmitterorReceiver

Unitfunctions,butsomecircuitsdonotwork,oroperatetheincorrectcircuit

QuickTouch®IIconfigurationisincorrect

Seepage50tosetupbuttons

Unitfailstooperate,orfailstooperatedependablyatrange

ExcessiveelectricalnoiseRelocatethereceiverawayfrom“noisy” electricalequipmentsuchasblowermotors

Toomanyobstructionsbetweenthetransmitterandreceiver

Relocatethereceiverawayfromgroundmetalandobstructions

Receiverunitistooneartheground

Relocatethereceivertomaximizethe distancebetweenthereceiverantennaandtheground

Page 72: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

64

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Symptom Possible Cause Solution

Unitseemstoturnonoroffcircuitswithouttheuser/ transmitter

Anearbyhomeis operatingasimilar wirelessunit

Selectanalternateaddresscodeforthetransmitterandreceiver.Changetheswitchesonbothreceiverandremotetoanalternate,butmatchingsetting.

Unitdependablyturns equipmentON,butonceequip-mentisrunningitdoesnotde-pendablyturnequipmentOFF,orrangeisgreatlyreducedwhenequipmentisrunning.

Undueelectricalnoiseisbeingproducedbyoneormorepiecesofequipmentincloseproximitytothereceiver.

RelocatetheReceiverawayfromequipmentsuchasblowermotors.Relocatethereceiverinalocationthatprovidesfewerobstructionstotheareatheusercom-monlyoperatesthetransmitter.

Unitoperates,buthasgreatlyreducedrangecomparedtopriorfunction

TransmitterBatteryisfailing.

ReplaceTransmitterbattery(type20323V).

Problem: TheQuickTouch®IIWirelessRemotewillnotwork,orwillnotworkdependably(Continued).

EasyTouch PL4/PSL4 Control System Wiring Diagram (Outdoor Control Panel)

PL4/PSL CONTROL SYSTEMFOR POOL AND SPAWIRING DIAGRAM

Page 73: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

65

First Time System Start-UpThefollowinginformationdescribesabasicsystemstart-upprocedure.BeforeyoupoweruptheEasyTouchPL4/PSL4ControlSystematthePowerCenterfirstcheckthefollowing:

Check ElectronicsCheckthatthefollowingplugsareseatedcorrectlyontheEasyTouchPL4/PSL4ControlSystemPowerCentermaincircuitboard.Forconnectorlocations,refertotheEasyTouchPL4/PSL4ControlSystemWiringDiagramonpage60.

• Relayconnectors-FLTR PUMP-AUX 1 - 3• Temperaturesensorsconnectors-WATER, SOLAR, AIR• Transformerwireharness- J1• Heatercontrolconnector- ELEC HTR and GAS HEATER (J19)

System TestFollowthestepsbelowtotesttheEasyTouchPL4/PSL4ControlSystemcontrolpaneltoactivatetheheater,valvesandpumps.ThistestassumesthatallsystemequipmenthasbeenproperlyinstalledandconnectedtotheEasyTouchPL4/PSL4ControlSystemPowerCenter.

TestingValveActuatorsandPumps:Usethefollowingstepstotestthevalveactuators(CVA24T)forproperrotation.

Totestthevalveactuatorsandpump:

1. Switchontheelectricalpoweratthehousebreaker.2. SwitchontheEasyTouchPL4/PSL4ControlSystemPowerCenter.Youmayneedtoswitchonthe

breakersonthePowerCenter.3. PresstheMode buttontoenable“Service”mode.4. PresstheValve (V)buttontoselect“Pool”mode.5. PresstheFilter Pump (F)buttontoactivatethefilterpump.Waterwillberemovedfromthepool

andreturnedtothepool.Aspabypasslinedivertasmallamountofwatertothespa.Makesurethefilterpumpturnsoncorrectly.Ifthepumphastwospeeds:Pressthebuttononetimetorunthepumpinlowspeed.Pressthebuttonagaintorunthepumpinhighspeed.Pressthebuttonagaintoswitchthepumpoff.ATwo-Speedpumphastobeconfiguredinthe2-Speedmenu(seepage46).

6. Setbothvalveactuators(CVA-24T)forsuctionandreturn.UsethetoggleswitchontherearoftheCVA-24Ttowithdrawandreturnwaterfromthepool.

7. PresstheValves (V)button.Stepthroughallfourvalvepositions:Pool,Spa,Fill,Drain.Makesurethevalvesturnoncorrectlyandthewaterismovinginthecorrectdirectionforeachposition.Ifnecessary,fliptheactuatortoggleswitchtochangethedirectionofthewater.

Note:Withthefilterpumpoperating,ifwaterisnotbeingremovedandreturnedtothepool,itmaybenecessarytoreversetheRETURNwithVLV A(orVLV B)plugsontheEasyTouchPL4/PSL4ControlSystemmaincircuitboard.

Testing the Auxiliary RelaysAffixtheauxiliaryrelaylabelstotheappropriatebuttonsontheEasyTouchPL4/PSL4ControlSystemOutdoorpaneland/ortheIndoorControlPanel.Ifnecessary,writethefunctiononthecontrolpanel.

1. Stepthroughtherestoftheauxiliarybuttons.Noticewhichbuttonturnsonwhichequipment.Youmayneedtowalkthepropertytofindwhateachbuttonturnson.

2. Writedownwhateachbuttonswitcheson,includingthenumberofthecircuit.YouneedthisinformationwhenyousetuptheIndoorControlPanel.

3. LabelthecircuitbuttonsontheoutdoorcontrolpanelandtheEasyTouchPL4/PSL4IndoorControlPanel.

Page 74: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

66

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

Setting up the Wireless Controller for the first timeSetting up the EasyTouch® PL4/PSL4 Control System Wireless Controller

InorderfortheEasyTouchPL4/PSL4ControlSystemWirelessControllertocommunicatewiththeEasyTouchPL4/PSL4ControlSystemOutdoorControlPanel,thefirsttimethewirelessdeviceispoweredupitmustfirstbeassignedauniquecommunicationaddress.Forthisprocessyouneedtoaccessthemenuforeachcontrolpanel.Forconvenienceit’seasiertosetupthewirelessdeviceattheoutdoorcontrolpanel.

From the EasyTouch PL4/PSL4 Control System Power Center outdoor control panel

1. SwitchpowerontothePowerCenter.

2. PressMenu button,andselectSettings > AddressandpresstheRightarrowbutton.

Theoutdoorcontrolpanelwilldisplay“Scanning...”foraboutfivesecondswhileitsearchesfortheWirelessControllerwithinrangeofthetransceiverantenna.Afterthescanningprocesshasfinished,“SendingAddress”isdisplayed.ThesystemisnowwaitingtolockontotheWirelessController.Proceedtostep3.

From the Wireless Controller

3. PressthePower OnbuttonlocatedonthefrontoftheWirelessController.

Note: Afterreplacingdepletedbatteriesacheckbatterymessageisdisplayedonthescreen.PresstheMENUbuttontwicetocontinue.

4. PressMenubutton,andselectSettings > AddressandpresstheRightarrowbutton.

5. Select“Address”andpresstheRightarrowbuttontolockontotheuniqueaddressthatisbeingtransmittedfromtheoutdoorcontrolpanel.

Note: If you choose “Abort,” the device can continue to operate using the factory default address. If the outdoor control panel has been previously addressed, the wireless may not operate the system. Each time the device is switched on the “NO ADDRESS” will be displayed. This mode is not recommended for permanent use.

6. Afterselecting“Address”thewirelessdeviceunitwilllockontoauniqueaddressanddisplay “FoundADDRESSED.”PresstheMenubuttontosaveandexitthismode.Thedeviceisreadyforoperation.

7. On the outdoor control panel:PresstheoutdoorcontrolpanelMENUbuttonthreetimestoexitthe“SendingAddress”modeandreturntothemainscreen.ThesystemwillcontinuetotransmitanaddressuntiltheMenuisbuttonispressedtostoptheprocess.

Note: To readdress the Wireless Controller, repeat steps 2 through 7 on the Wireless Controller to restart the address process.

Note: “Unit Mismatch” displays if the outdoor control panel has an existing system image. See page 12 for details.

Address Wireless Sending Address.. <MENU>

Address Wireless Scanning ...

NO ADDRESS Address Abort

Address Lock Found ADDRESSED <MENU>

Unit Mismatch Download from Outdoor

Page 75: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

67

Synchronizing control panelsIftheEasyTouch®PL4/PSL4ControlSystemOutdoorControlPanelwaspreviouslysetupwithspecificpoolandspainformationandanadditionalindoororwirelesscontrolpanelwithfactorydefaultinformationisinstalled,duringtheinstallationprocesstheoutdoorcontrolpanelwillautomaticallydownloadthesysteminformationtotheconnectedcontrolpanel.Iftheoutdoor,indoororwirelesscontrolpanelshavedifferentrevisionlevelsorcontainprevioussetupinformation,youcanchoosewhichsystemimagetouploadordownload.

Synchronizingcontrolpanelsisinitiatedfromtheindoororwirelesscontrolpanel.Thefollowingdescribeshowtosynchronizeanindoororwirelesscontrolpanel.

Download from outdoor control panel to indoor control panel

• PresstheMenubuttontodownloadthesystemimagefromtheEasyTouchPL4/PSL4ControlSystemoutdoorcontrolpanel.

Upload to outdoor from indoor control panel1. PresstheUp/Downbuttontoaccessthe“Upload”screen.

2. PresstheMenubuttontouploadthesystemimagefromtheindoororwirelesscontrolpaneltotheEasyTouchPL4/PSL4ControlSystemoutdoorcontrolpanel.

Note:Toeraseexistingcontrolpanelsysteminformation,usethe“EraseEEPROM”feature.Referto“EraseEEPROM”onpage52formoreinformation.

Wiring UltraTemp® Heat Pump to EasyTouch PL4/PSL4 Control SystemBesuretochecktheUltraTempHeatPumpterminalblockwirecolorsandpinouts(locatedonthebackoftheAutoSetboard)beforeconnectingittotheEasyTouchPL4/PSL4ControlSystemCOMportonthemaincircuitboard.TheSeethewiringtablebelowforthepinconfiguration.ForUltraTempHeatPumpsetupinformation,seepage41.

IMPORTANT: On the UltraTemp Heat Pump AutoSet board ONLY CONNECT PIN 3 (YELLOW) and PIN 2 (GREEN) to the EasyTouch PL4/PSL4 Control System COM port pins YELLOW and GREEN respectively. Do not use pin 1 or pin 4 on the AutoSet board or the EasyTouch PL4/PSL4 Control System main circuit board. These pins are not used.

Wiring Description

EasyTouch PL4/PSL4 Control System COM port wire color

DescriptionUltraTemp Heat Pump pin number and wire color

PIN4(RED)NOT USED +15VDC PIN 4 (RED) NOT USED

PIN3(YELLOW) +DATA PIN3(YELLOW)

PIN2(GREEN) -DATA PIN2(GREEN)

PIN1(BLACK)NOT USED GROUND PIN 1 (BLACK) NOT USED

Unit Mismatch Download from Outdoor

Unit Mismatch Upload to Outdoor

Page 76: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

68

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

GlossaryControl Panel:TheEasyTouch®PL4/PSL4ControlSystemOutdoorControlPanelwithflexiblehinge.InstalledinupperportionofEasyTouchPL4/PSL4controlsystemPowerCenter.

Feature Circuits:Programmablecircuitsthatmaycontrolrelaysand/orvalveactuators.Fordetails,seetheEasyTouchPL4/PSL4ControlSystemSystemsUser’sGuide(P/N522461)

High Voltage Panel/Compartment: RemovablepanelforthehighvoltagecompartmentofEasyTouchPL4/PSL4PowerCenter.Thehighvoltagewiringincluding18Vand24Vcircuitbreakers,relaysandGFCI.

Indoor Control Panel: ThiswallmountedremotecontrollerwithLCD(liquidcrystaldisplay)iswiredtothecontrolcircuitboardintheEasyTouchPL4/PSL4controlsystemPowerCenter.ThecontrolpanelcanbewallmountedinsideahousetocontroltheEasyTouchPL4/PSL4controlsystem.

IntelliChlor® Salt Chlorine Generator (SCG):Usesaprocesscalledelectrolysistoproducesodiumhypochlorite(liquidchlorine)fromalowconcentrationofsaltaddedtothepoolwater.ModelIC20Cell(P/N520554)forpoolsupto20,000U.S.gallons(75liters)andmodelIC40Cell(P/N520555)forpoolsupto40,000U.S.gallons(151liters).TheexternalIntelliChlorPowerCenter(P/N520556).

iS4 Wireless Controller:Fourfunctionspa-sideremote.Spawallordeckmounted.

Outdoor Control Panel:ControlpanelwithflexiblehingeinstalledinupperportionofPowerCentertocontrolEasyTouchPL4/PSL4controlsystem.

Power Center:Metalenclosurewithpowerrelays,transformer,and18Vand24Vinternalcircuitbreakers.UsedfordistributingpowerforcontrollingEasyTouchPL4/PSL4controlsystem.

Low Voltage Compartment:TopcompartmentofPowerCenterforalllowvoltagewiring.

Low Voltage Raceway:VerticalspaceintheleftsideofPowerCenterforlowvoltagecabling.

Main Circuit Board:ThecircuitboardmountedbehindtheEasyTouchPL4/PSL4controlsystemcontrolpanel.

Relay Circuits:Thecircuitsthatcontroltherelaysonthecircuitboard.Connectorsontopedgeofthecircuitboard.

Screw Terminal Connector:Removableconnectorthatmayattachtocircuitboardwithmultiplesockets(anywherefrom2to6)toreceiveconductorsfromcontrollersandsensors;conductorsheldbyscrewterminals;multipleconductorsofasmallenoughgauge(usually22AWG)maybecoupledtoasinglesocketofaterminalconnector.

Salt Chlorine Generator:Automatedpoolchlorinatorthatsanitizesusingsalttoproducefreechlorine.

Transceiver:Circuitboardwithattachedantennathatcansendandreceiveradiofrequency(wireless)transmissions.UsedwithQuickTouch®IIWirelessController.

Wireless Controller (QuickTouch® II Controller):WirelesscontrollerfortheEasyTouchPL4/PSL4ControlSystemwithallthefunctionalityoftheIndoorControlPanel.ConnectedtoatransceiverwhichisconnectedtotheCOMportonthemaincircuitboard.(seeIntelliChlorSCGabove).

Page 77: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

69

NOTES

Page 78: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

70

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

NOTES

Page 79: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

EASYTOUCH® PL4/PSL4 Control Systems User’s Guide

71

NOTES

Page 80: PL4/PSL4 CONTROL SYSTEM · Control System is intended to control heaters with built-in high limit circuits ONLy. Failure to do so may cause property damage or personal injury. Do

1

1620 HAWKINS AVE., SANFORD, NC 27330 • (919) 566-800010951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 • (805) 553-5000

www.pentair.com

All indicated Pentair trademarks and logos are property of Pentair Inc. or its global affiliates in the U.S.A.and/or other countries.Third party registered and unregistered trademarks and logos are the property of their respective owners.

© 2020 Pentair. All rights reserved. This document is subject to change without notice.

*522461*

P/N 522461 REV. C 2/2020