pilot cove - insight lighting cove... · acj-2-w 2’ white jumper cable ... pilot cove interior...

5

Click here to load reader

Upload: vocong

Post on 07-Aug-2018

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PILOT COVE - Insight Lighting Cove... · acj-2-w 2’ white jumper cable ... pilot cove interior ... additiona l backing with nec article 725. may be required

PILOT COVEINTERIOR - INTEGRAL POWER SUPPLY

WHITE LIGHTSHAPING THE EXPERIENCE OF LIGHT®

PLC-WHITE LIGHT January 19, 2018 9:16 AM

Page 1 of 5

Insight Lighting. Specifications are subject to change without notice.4341 Fulcrum Way NE, Rio Rancho, NM 87144Tel: 505.345.0888 / www.insightlighting.com

LIGHT SOURCE 3.5W/FT, 6W/FT, 11W/FT

OPTICS

COLOR TEMPERATURES (C.C.T.)

2700K 3000K 3500K 4000K

CRI Standard: 83+ (Color tolerance = ±200)

LUMENS & EFFICACY

3.5W IS ASHRAE COMPLIANT AND IS SUIT-ABLE FOR TITLE 24

4' - WHITE LIGHT (4000K, 83CRI)

WATTAGE OPTICS LUMENS EFFICACY

3.5 W/ft6.0 W/ft

11.0 W/ft

120°120°120°

153524514249

113.7 lm/W108.0 lm/W

96.1 lm/W

LUMEN MAINTENANCE

75,000 hrs L70

ELECTRICAL LINE VOLTAGE

DIMMING

INTEGRAL POWER SUPPLY, 120V OR 277V

0-10V, DMX, LUTRON ECO-SYSTEM

TOTAL POWER CONSUMPTION

FIXTURE WATTAGE 3.5 W/ft6.0 W/ft

11.0 W/ft

TOTAL POWER CONSUMPTION3.5 W/ft6.0 W/ft

11.0 W/ft

CONTROL 0-10V & DMX DIMMING DMX Dimming (Delivered Output Ratio = .75)

PHYSICAL

DIMENSIONS(HEIGHT X WIDTH)

WITH FLAT LENS: 3/4" X 1-5/8" WITH WHITE DIRECT VIEW DOME LENS: 1-3/8" X 1-5/8"

HOUSING Aluminum extrusion with molded end caps, powder-coated finish, White

LENS Flat Clear Acrylic Lens is standard

Optional "Flat White Acrylic Lens" is available with 120° optics only. Allows for smooth light distribution, but does not remove diode images.

Optional "White Direct View Lens" (DV) for direct view applications is available with 120° optics only. The Direct View Lens option creates a crisp white illuminattion and eliminates all diode images.

OPERATING TEMPERATURES -25° C to 40° C

CERTIFICATIONRoHSCOMPLIANT

ETL Listed for Dry Location

WARRANTY 5 Year Limited

Warranty

5 Year Limited

All PILOT® products are tested to IES LM-79 standards

Page 2: PILOT COVE - Insight Lighting Cove... · acj-2-w 2’ white jumper cable ... pilot cove interior ... additiona l backing with nec article 725. may be required

PILOT COVEINTERIOR - INTEGRAL POWER SUPPLY

WHITE LIGHTSHAPING THE EXPERIENCE OF LIGHT®

PLC-WHITE LIGHT January 19, 2018 9:16 AM

Page 2 of 5

Insight Lighting. Specifications are subject to change without notice.4341 Fulcrum Way NE, Rio Rancho, NM 87144Tel: 505.345.0888 / www.insightlighting.com

INTERIOR LEADER CABLES

• An AC Leader Cable is required with each fixture run for connection from first fixture to the j-box.

ACL-5-W 5’ WHITE LEADER CABLE - For line voltage only, Used for connection to the start of each run.

INTERIOR JUMPER CABLES

• ACV WIRING METHOD allows for end-to-end fixture connection without additional AC jumpers. If fixtures are not mounted in an end-to-end continuous manner, AC jumpers are required.

CATALOG # DESCRIPTION CATALOG # DESCRIPTION

ACJ-2-W 2’ WHITE JUMPER CABLE - For line voltage only ACJ-10-W 10’ WHITE JUMPER CABLE - For line voltage only

ACJ-5-W 5’ WHITE JUMPER CABLE - For line voltage only ACJ-25-W 25’ WHITE JUMPER CABLE - For line voltage only

PLC

ORDER ING INFORMATIONPREFIX WATTAGE

WATTS /FTCCT OPTICS MOUNTING FIXTURE

LENGTHVOLTAGE/

WIRING METHODCONTROL OPTIONS

(DIMMING)FINISH OPTIONS

PLC

Pilot CoveSeries

3.5

6 11

27K30K35K40K

30° = 120° =

30° X 60°120° X 120°

HM = Hinge

FM = Fixed

24"

36"

48"

ACV1 = 120V feed thru wiring for end-to-end fixture connection

ACV2 = 277V feed thru wiring for end-to-end fixture connection

Load not to exceed 16 amps

See cable requirements below

NO = No Dimming

DIM = 0-10V Dimming

DMXDM = DMX Dimming Resolution per power supply

LES-LDE1 = Lutron Hi-Lume 1% EcoSystem® dimming with Soft-on, Fade-to-Black™ (Available with 24" - 96" fixtures only)

LES-L3D = Lutron Hi-Lume 1% EcoSystem® /3--Wire dimming with Soft-on, Fade-to-Black™ (Available with 24" - 96" fixtures only)

W = Semi-Gloss White

Contact factory for additional finishes

WL = Flat diffusing lens (Available with 120° optics only)

DV = Direct view dome lens for direct view applications (Available with 120° optics only)

Contact factory for MRI applications

3.5W IS ASHRAE COMPLIANT3.5W IS SUITABLE FOR TITLE 24

Page 3: PILOT COVE - Insight Lighting Cove... · acj-2-w 2’ white jumper cable ... pilot cove interior ... additiona l backing with nec article 725. may be required

PILOT COVEINTERIOR - INTEGRAL POWER SUPPLY

WHITE LIGHTSHAPING THE EXPERIENCE OF LIGHT®

PLC-WHITE LIGHT January 19, 2018 9:16 AM

Page 3 of 5

Insight Lighting. Specifications are subject to change without notice.4341 Fulcrum Way NE, Rio Rancho, NM 87144Tel: 505.345.0888 / www.insightlighting.com

HM - HINGE MOUNT

DIM 'A'

DIM 'B'

DIM 'C'

DIM 'E' 2x clearance holes for #8 mounting hardware (by others, per hinge)

DIM 'D'

TOP VIEW

FRONT VIEW

BOTTOM VIEW

2-1/8"

3-3/8"3-7/8"

SIDE VIEW

2-3/8" 4-3/8"

100°

FIXTURE ROTATION

DIRECT VIEWDOME LENS

FLAT LENS

Static White, Dimming, RGBWWA, Dim DMX & RGB+WFixture DIM -A- DIM -B- DIM -C- DIM -D- DIM -E-

24" 24-1/2" 4" 16-1/2" 4" to 14"36" 36-1/2" 10" 16-1/2" 1-1/4" to 6-1/4"<

1-1/4" to 6-1/4"<4" to 14"

48" 48-1/2" 16" 16-1/2" 1-1/4" to 6-1/4"< 4" to 14"

1-1/4"

2X Ø 1/8"FOR #6 MOUNTINGFASTENERS (BY OTHERS)

MOUNTING BRACKET DETAIL

2-1/8"

2-5/8"3-1/8"

INPUT

DIRECT VIEW LENSIS OPTIONAL

FLAT CLEAR LENSIS STANDARD WITH

HINGE MOUNT

Page 4: PILOT COVE - Insight Lighting Cove... · acj-2-w 2’ white jumper cable ... pilot cove interior ... additiona l backing with nec article 725. may be required

PILOT COVEINTERIOR - INTEGRAL POWER SUPPLY

WHITE LIGHTSHAPING THE EXPERIENCE OF LIGHT®

PLC-WHITE LIGHT January 19, 2018 9:16 AM

Page 4 of 5

Insight Lighting. Specifications are subject to change without notice.4341 Fulcrum Way NE, Rio Rancho, NM 87144Tel: 505.345.0888 / www.insightlighting.com

Fixture DIM "A" DIM "B"24" 24-1/2" 6" TO 15"36" 36-1/2" 6" TO 15"

48" 48-1/2" 6" TO 15"

2 3/4" 2 5/8"

2 1/8"

3"

SIDE VIEW

2 5/8"

1/2"

3"

2X Ø .188 THRUFOR #6 MOUNTING

FASTENERS(BY OTHERS)

MOUNT BRACKET DETAILS

DIM "A"

16 3/8"

Ø 1 1/8"Ø 1.25 THRU HOLE

RECOMENDED

3/8"

FRONT VIEW

DIM "B" / 2

DIM "B"

TOP VIEW

CL

INPUT

3 3/8" 3 3/8"

2 1/8"

3"

SIDE VIEW

DIM "A"

3/8"

FRONT VIEW

DIM "B"

DIM "B" / 2

CL

TOP VIEW

16 3/8"

Ø 1 1/8"Ø 1.25 THRU HOLE

RECOMENDED

INPUT

FM - FIXED MOUNT

DIRECT VIEW LENSIS OPTIONAL

FLAT CLEAR LENSIS STANDARD

Page 5: PILOT COVE - Insight Lighting Cove... · acj-2-w 2’ white jumper cable ... pilot cove interior ... additiona l backing with nec article 725. may be required

PILOT COVEINTERIOR - INTEGRAL POWER SUPPLY

WHITE LIGHTSHAPING THE EXPERIENCE OF LIGHT®

PLC-WHITE LIGHT January 19, 2018 9:16 AM

Page 5 of 5

Insight Lighting. Specifications are subject to change without notice.4341 Fulcrum Way NE, Rio Rancho, NM 87144Tel: 505.345.0888 / www.insightlighting.com

Next To

Data In

0-10V DIMMING

Neutral White

Ground Green

Line Black

Data - BlueData + Yellow

Fixture

Previous

From

To Fixture

Fixture

NON DIMMING

Ground Green

24 AWG DATA PAIR IF APPLICABLE

( BY OTHERS )

( BY OTHERS )

Line Black

ACV

120 - 277 AC LINE

J-BOX BY OTHERS ( TYP. )

Neutral White

ACL REQUIRED

To

0-10 SOURCE, IF APPLICABLE

( 4FT LEAD PROVIDED TYP. )

To Fixture

From

Previous Fixture

Next Fixture

BY OTHERS,

CAPPED ENDOR INT

5/1/15

TYPICAL WHITE AND 0-10 ACV WIRING CONCEPT

● 800' MAX. TOTAL CABLE LENGTH.● 32 FIXTURES MAX PER OUTPUT.

MAXIMUM FIXTURE RUN LENGTHS16 AMP, 120V CIRCUIT

WHITE LIGHT, STATIC COLORS AND RGB APPLICATIONS

32 FIXTURES @ 15 WATTS PER FOOT

16 AMP, 277V CIRCUIT WHITE LIGHT, STATIC COLORS AND RGB APPLICATIONS

32 FIXTURES @ 15 WATTS PER FOOT

CAUTION: THIS IS AN ELECTRONIC DEVICE. CARE MUST BE TAKEN DURING STORAGE AND HANDLING. STORE IN CLEAN, COOL, AND DRY LOCATION. ELECTROSTATIC DISCHARGE (ESD) CAN HARM THIS PRODUCT. AVOID STATIC DISCHARGE WHILE HANDLING THIS PRODUCT.

CAUTION:

WARRANTIES!

INSIGHT LIGHTING IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY CONNECTIONS SHALL BE MADE IN ACCORDANCE

ON THIS FIXTURE VOIDS ALL

NOTICE: SECONDARY

OF THE BUILDING TO SUPPORT THE LUMINAIRE. ADDITIONAL BACKING WITH NEC ARTICLE 725.MAY BE REQUIRED.

WIRING DETAILS

WARNING: REMOVAL OF END CAP

ALL ELECTRICAL CONNECTIONS TO BE MADE BY A LICENSED ELECTRICIAN.

MAKE SURE ALL ELECTRICAL POWER IS OFF WHEN INSTALLING LUMINAIRES.

WARNING:

WARNING:

1 OF 1