pi nl - profibus · overview profinet copper cable type a type b type b hybrid type c standard...

24
PI NL 16-10-2018 | Kantoor vs fabriek? | © 2018 PROCENTEC All rights reserved Kantoorautomatisering belangrijker dan fabriek?

Upload: others

Post on 30-May-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

PI NL

16-10-2018 | Kantoor vs fabriek? | © 2018 PROCENTEC All rights reserved

Kantoorautomatisering belangrijker dan fabriek?

Page 2: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

Infrastructurele netwerkconcepten in de KA worden gemiddeld tussen de 15 en 25 jaar gecertificeerd.

Waarom gebeurt dit in de KA wél, maar in de fabriek niet?

Met onze ruim 20 jaar ervaring in het veld, concluderen wij dat

90% van alle fouten in de bekabeling zit. Richtlijnen voor een optimale PROFIBUS of PROFINET architectuur

worden in de praktijk vaak aan de laars gelapt.

Wij houden u de spiegel voor, voorkom onnodige faalkosten en downtime!

18 April 2017 | PROCENTEC Hannover Network | © 2017 PROCENTEC All rights reserved

Page 3: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

Agenda

• Introductie

• IT belangrijker dan OT?

• Feiten KA

• Feiten OT

• Propositie

• NA-IJL-EFFECT

• EHBO functie + conclusie

• Vragen

16-10-2018 | Kantoor vs fabriek? | © 2018 PROCENTEC All rights reserved

Page 4: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

Introductie

Clement JenseAccount Manager | Business Development

Klopperman 162292 JD WateringenThe Netherlands

Email: [email protected]: +31(0)6 125 151 17 Office: +31(0)174 671 800

Focus & about: • Account Management• Business Development• Partnering

https://www.linkedin.com/in/clementjense

16-10-2018 | Testlab | © 2018 PROCENTEC All rights reserved 4

Page 5: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

16-10-2018 | Kantoor vs fabriek? | © 2018 PROCENTEC All rights reserved

Feiten KA (IT)

Page 6: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

16-10-2018 | Kantoor vs fabriek? | © 2018 PROCENTEC All rights reserved

Feiten OT

Page 7: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

16-10-2018 | Kantoor vs fabriek? | © 2018 PROCENTEC All rights reserved

Reliability ComponentsKnowlegde

End-userPreventing downtime

Predictive MaintenanceAsset Management

Global & Local

Vendor PS /Key Accounts

Certified Engineers

Certified System Integrators

and OEM

Page 8: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

16-10-2018 | Kantoor vs fabriek? | © 2018 PROCENTEC All rights reserved

meten is

weten

voorkomenis beter dan

genezen

Knowledge

Preventing downtimePredictive Maintenance

Asset Management

EngineeringProcurementConstruction

CivielAutomationMechanical

E&I

Project

Chemicals

Steel, Waste &

Energy

Water

Logistics

OEM

Food &

Beverage

Oil & Gas

Global & Local

Page 9: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

16-10-2018 | Kantoor vs fabriek? | © 2018 PROCENTEC All rights reserved

Page 10: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

PROCENTEC BVKlopperman 162292 JD WateringenThe NetherlandsT: +31 (0)174 671 800F: +31 (0)174 671 801E: [email protected]: www.procentec.com

Contactinformatie

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved

Page 11: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

PI Nederland

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved

Guidelines, aarding & shielding

Page 12: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

Cable types

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved 12

All kinds of cables are available for areas in which the standard PROFIBUS cable cannot be used.

Offshore cable

Festoon cableStandard cable

flexible core

EMC cable

Fire proof cableStandard cablesolid core

Ground cable

Hybrid cable Hybrid festoon cableSteel armoredground cable

PROFIBUS PA cable(solid core)

PROFIBUS PA cable(flexible core)

Page 13: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

Overview PROFINET copper cable

Type A Type B Type B Hybrid Type C

Standard Cable Flexible Cable Flexible Cable with additional wires for power supply

Trailing cable

Solid core Stranded core Stranded core Stranded core

static installatione.g. in cable trays.

frequent flexing or bending

e.g. mobile machine parts

High flexible applicatione.g. trailing chains

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved 13

Page 14: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

Overview PROFINET 8-core copper cable

Type A Type B Type C

Standard Cable Flexible Cable Trailing cable

Solid core Stranded core Stranded core

static installatione.g. in cable trays.

frequent flexing or bending e.g. mobile machine parts

High flexible applicatione.g. trailing chains

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved 14

Page 15: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

Cable types – EMC cable

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved 15

Page 16: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

Earthing and grounding must be considered at:

• Planning

• Installation

• Inspection, maintenance, troubleshooting

Influences on data communication

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved

Currents

Sender Receiver

EMI

16

Page 17: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

• The twist in the wires eliminates magnetic fields.

• Try to keep the twist in the wires when the sheath has been removed.

• This theory is valid for all signal carriers!

Electromagnetic injection

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved

Induced currents in adjacent loops tends to cancel

Pickup

17

Page 18: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

• The shielding of the cable reduces electrostatic injection!

• Ground multiple points (resistance reduction).

• As thick possible.

• Non grounded shielding has no effect!

Electrostatic injection

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved

High Voltage

Interference sourcee.g. Power cable

Pickup

Pickup passes through groundRs Rs Rs

Rs = Shield resistance (normally 9.5 Ohm/km)

18

Page 19: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved

Shielding

19

Page 20: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

Potential Equalization

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved

Ground cable

Cabinet 2 Cabinet 3

ground rail ground rail ground rail

Cabinet 1

20

Page 21: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

Policy of separation

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved

As far away as possible!

Power line

As close as possible!Ground potential

21

Page 22: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

Cable separation

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved

PROFIBUS and PROFINET cable and cables for:

Spacing

Without partition or with non-metallic partition

Partition made out of aluminum

Partition made out of steel

Signal transmission

Network signals such as PROFIBUS and PROFINETDigital data signals for PCs, programming devices, printers, etc.Shielded analog inputs or outputs

0 mm 0 mm 0 mm

Power supply

Unshielded (≥ 230V) 200 mm 100 mm 50 mm

Shielded (≥ 230V) 0 mm 0 mm 0 mm

22

Page 23: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

PI PROFINET Guidelines

• PROFINET Design Guideline - Order No.: 8.062

• PROFINET Installation Guideline for Cabling and Assembly - Order No.: 8.072

• PROFINET Commissioning Guideline - Order No: 8.082

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved 23

Page 24: PI NL - PROFIBUS · Overview PROFINET copper cable Type A Type B Type B Hybrid Type C Standard Cable Flexible Cable Flexible Cable with additional wires for power supply Trailing

PROCENTEC BVKlopperman 162292 JD WateringenThe NetherlandsT: +31 (0)174 671 800F: +31 (0)174 671 801E: [email protected]: www.procentec.com

Contactinformatie

16-10-2018 | Guidelines, aarding & shielding | © 2018 PROCENTEC All rights reserved