phase 1 sitewide soil vapor investigation report-figures1...221 sunset phase 1 sitewide soil vapor...
TRANSCRIPT
Figures
!?
!?!?
!?
!?!?
!?
!?
Hulett Lagoon
FormerManufacturing
Facility
Suns
et La
ne
Forestway Drive
Mulberry Drive
Sunset Drive
Bent Tree Lane
OakHill
DriveDa
wson
Roa
d
FIGURE 1-1Site Location Map
Phase I Sitewide Soil Vapor Investigation Report221 Sunset Drive, Camdenton, MO/
0 200 400Feet
\\Brookside\GIS_SHARE\ENBG\00_Proj\M\Modine_Manufacturing\Modine_Manufacturing_478510\MapFiles\Sitewide_Investigation_Report\Figure1_1_Site_Location.mxd ag017958 1/18/2017
Legend!? Sanitary Sewer Manhole
Sanitary Sewer LineTarget Investigation Area
Imagery Source: ESRIBASE MAP SOURCE:USDA, Farm Service Agency (FSA), National AgricultureImagery Program (NAIP), 2014
!?
!?!?
!?
!?!?
!?
!?
&<&<
&<&<
&<&<&<&<&<
&<&<
&<&<&<&< &<&<
&<
&<&<
&<&<
&<&<
&<
&<&<
&<&<#*
#*
#*
#*#* #*
#*
#*
#* #*
#*
Hulett Lagoon
FormerManufacturing
Facility
MW-111SMW-111D/SB-111D
MW-116SMW-116D/SB-116D
MW-117S/SB-117S
MW-110D/SB-110DMW-110S
MW-109D/SB-109DMW-109S
MW-108SMW-108D/SB-108D
MW-115D/SB-115DMW-119D/SB-119D
MW-119SMW-100
MW-101
MW-102
MW-103
MW-104MW-107
MW-106MW-105
MW-114SMW-114D/SB-114D
MW-118S/SB-118S
MW-112SMW-112D/SB-112D
MW-113SMW-113D/SB-113D
Suns
et La
ne
Forestway Drive
Oak Hill Drive
Mulberry Drive
Daws
on R
oad
Sunset Drive
Bent Tree Lane
FIGURE 2-1Sample Location Map
Phase I Sitewide Soil Vapor Investigation Report221 Sunset Drive, Camdenton, MO/
0 200 400Feet
\\Brookside\GIS_SHARE\ENBG\00_Proj\M\Modine_Manufacturing\Modine_Manufacturing_478510\MapFiles\Sitewide_Investigation_Report\Figure2_1_Sample_Locations.mxd ag017958 1/17/2017
Legend&< Monitoring Well#* Exterior Soil Vapor Probe!? Sanitary Sewer Manhole
Sanitary Sewer LineTarget Investigation Area
BASE MAP SOURCE:USDA, Farm Service Agency (FSA), National AgricultureImagery Program (NAIP), 2014
#
#
#
## #
#
#
# #
#
!?
!?!?
!?
!?
!?
!?
!?
&<&<
&<&<
&<&<&<&<&<
&<&<
&<&<&<&< &<&<
&<
&<&<
&<&<
&<&<
&<
&<&<
&<&<
Daws
on R
oad
Mulberry Drive
Sunset DriveMW-111S (7-12 ft bgs)
3,510
MW-116S (10-15 ft bgs)8,680
MW-117S(5-15 ft bgs)
2,180
MW-110S(5-10 ft bgs)
134,000
MW-109S(5-10 ft bgs)
2,800
MW-108S (10-15 ft bgs)5,260 J
MW-119S(10-20 ft bgs)
2,550
MW-100 (6.3-16.3 ft bgs)56,300 MW-103
(3.7-8.7 ft bgs)7,540
MW-104(3.7-5.7 ft bgs)
150MW-107 (4.7-14.7 ft bgs)
5.84 J
MW-114S (8-18 ft bgs)49,500
MW-118S(5-15 ft bgs)1,270,000
MW-112S (6-11 ft bgs)3,120
MW-113S(7-12 ft bgs)
255,000
SV187.65
SV1251.3
SV13500
SV14278
SV161,770
SV171,800
SV1572.1
SV19350
SV08 (3.5-4.5 ft bgs)8,030
SV03(5-6 ft bgs)
83
SV09(7.9-8 ft bgs)
16.3
Figure 3-1 TCE Concentrations in Shallow Soil Vapor
Phase I Sitewide Soil Vapor Investigation Report221 Sunset Drive, Camdenton, MO/
0 250125
Scale in Feet
\\brookside\GIS_SHARE\ENBG\00_Proj\M\Modine_Manufacturing\Modine_Manufacturing_478510\MapFiles\Sitewide_Investigation_Report\Updated_MXDs\Figure3_1_TCE_Shallow_Soil_Vapor.mxd 1/20/2017 saselage
Legend&< Monitoring Well!? Sanitary Sewer Manhole# Exterior Soil Vapor Probe
Sanitary Sewer Line
Notes:1. Samples collected 9/28 through 10/17/2016.2. Results are presented in micrograms per cubic meter (µg/m3).3. Bold result indicates that the chemical was detected at the value reported.4. ft bgs = feet below ground surface5. J = The analyte was positively identified; the associated numerical value is the approximate concentration of the analyte in the sample.6. TCE = trichloroethene
BASE MAP SOURCE:USDA, Farm Service Agency (FSA), NationalAgriculture Imagery Program (NAIP), 2014