petroleum standards

Upload: mark-anthony

Post on 15-Oct-2015

106 views

Category:

Documents


1 download

DESCRIPTION

Great ONE.

TRANSCRIPT

  • 5/25/2018 Petroleum Standards

    1/116

    AccuStandard

    Certified

    Reference

    Standards4th Edition

    P

    ET

    RO

    LEU

    M

    OvASTMM

    Member

  • 5/25/2018 Petroleum Standards

    2/116

    M

    New Products in this Catalog

    Low Sulfur and Nitrogen Standards (see pages 6-11)

    LUFT/LUST Standards (see pages 81-98) TPH Standards (see pages 81, 92-93, 96-97)

    No Haz Fee ICP & AA Standards (see pages 67-75)

    Additional New ASTM Standards

    Involvement in the Petrochemical Industry Participation in regular ASTM meetings

    Active in D-02 and D-16 subcommittees

    Provides support to several Petrochemical Instrument Manufacturers

    Resources Low Sulfur Analyzers (such as XOS) for Measurements to ppb Levels

    Instrumention for Analyzing Standards for ICP, ICP-MS, AA, GC/MS,

    GC/FID, GC/EC, GC/NPD, Karl Fischer Titrator, and others

    NIST/NVLAP Accredited (Lab Code 200389-0) as a PT Provider

    ISO 9001:2000 Certified (ISO 9001 for the last 10 years)

    Extensive Inventory of ASTM and Related Standards

    Experience in Petrochemical Requirements Years of Round Robin Studies with ASTM

    Ampulled over 300 gallons of ASTM fuel sets including

    over 35 gasoline and hydrocarbon blends

    Standards for over 100 ASTM Methods

    17 years of Manufacturing, Organic & Inorganic Standards Synthesizes rare Hydrocarbons not otherwise available

    Notice the Difference with AccuStandard

    PRINTED ONRECYCLED PAP

    AccuStandard, Inc. 2003

  • 5/25/2018 Petroleum Standards

    3/116

    Table of Contents

    Wear Metals GroupSulfur Standards Group

    Quality System is Certified to comply with the International ISO 9001:2000 Quality Standard

    Q

    ASTM # Method Description paD-5441 MtBE Analysis by GCD-5442 Petroleum Waxes by GCD-5443 PNA Analysis by Multidimensional GCD-5453 Sulfur by Ultra Violet FluorescenceD-5480 Engine Oil Volatility by GCD-5482 Vapor Pressure Standards 29D-5501 Ethanol Analysis by GCD-5580 Aromatics by GC 32D-5599 Oxygenates by OFID 34D-5600 Trace Metals by ICP

    D-5622 Oxygenates by Reductive PyrolysisD-5623 Sulfur Compounds by Sulfur Selective DetectionD-5708 Trace Metals by ICP 39D-5762 Nitrogen by ChemiluminescenceD-5769 Aromatics by GC/MS 42D-5771 Cloud Point of Petro ProductsD-5772 Cloud Point of Petro Products (Linear Cooling Rate)D-5773 Cloud Point of Petro Products (Constant Cooling Rate)D-5863 Trace Metals by AAD-5901 Freezing Point Aviation Fuels (Auto Optical Method)D-5972 Freezing Point Aviation FuelsD-5986 Oxygenates and Aromatics by GC/FTIRD-6160 PCBs by GCD-6258 Solvent Red 164 Dye Concentration in Diesel FuelsD-6277 Benzene in Spark Ignition FuelsD-6293 Oxygenates (O-PONA) in Engine Fuels by GCD-6296 Total Olefins in Spark Ignition Engine Fuels by GCD-6304 Water in Liquid Petro Products

    D-6334 Sulfur in Gasoline by Wavelength WD-XRF 10D-6352 Boiling Range Distribution of PetroleumD-6378 Vapor PressureD-6379 Aromatic Hydrocarbon by HPLCD-6417 Engine Oil by GCD-6428 Sulfur by ECDD-6443 Metals in Oil 58D-6445 Sulfur in Gasoline by ED-XRF 10D-6481 Lube Oils by ED-XRF 58, 63D-6550 Olefin Content of Gasoline by SFCD-6591 Aromatic Hydrocarbon by HPLC(IP 391)E-1064 Water in PetroleumISO/CD V & Ni with Mn

    Organometallic (Wear Metals) Analysis by AA, ICP, DCP, XRF 26, 28, 59Plasma Emission Spectroscopy (ICP) 67ICP (No Haz Fee) New 67

    Atomic Absorption Spectroscopy (AA) 67, 73AA (No Haz Fee) New 67, 73Plasma Emission / Mass Spectroscopy (ICP/MS)Trace Metals, Chlorine in Lube Oil, and Organo Tin NewIon Chrom 76

    LUFT/LUST and TPH (New Section) 81

    IndexQuote Form bOrder Information b

    D-3605 Trace Metals in Gas Turbine Fuel by AAD-4628 Wear Metals in Lube OilD-4927 Wear Metals and Additives by WDXRF 25, 63D-4951 Wear Metals and Additives by ICPD-5185 Wear Metals and Additives by ICPD-5708 Trace Metals by ICP 39,D-5863 Trace Metals by AAD-6443 Metals in Oil 58,D-6481 Lube Oils by ED-XRF 58, 63

    ASTM # Method Description pageCross Reference Tables (ASTM,IP,ISO,DIN,JIS,AFNOR) IIAnalytical Capabilities IIIOn-Line Ordering IVQuality Control 1-2

    D-56 Flash Point Standards 3D-86 Synthetic Distillation Standard 3D-92 Flash Point Standards (COC) 3D-93 Flash Point Standards (PMCC) 3D-445 Viscosity Calibration Standard 3D-611 Aniline Point Standard 4

    D-1015 Freezing Point Standards 4D-1319 Olefin Analysis by FIA 4D-1744 Water in Liquid Petroleum Products 5D-2386 Freezing Point Calibration Standards 5D-2500 Cloud Point Calibration Standards 5D-2622 Sulfur by XRF 10D-2789 Hydrocarbon Analysis in Gasoline by GC/MS 11

    PIANO, PONA, PNA by GC 12-13Proposed Method for Detailed Hydrocarbon Analysis 14Detailed Hydrocarbon Analysis PONA VI 14

    D-2887 Boiling Range by GC 14Simulated Distillation (SIM DIS) by GC 15

    D-3120 Sulfur by Oxidative Microcoulometry 16D-3230 Salts in Crude Oil 16D-3231 Phosphorus in Gasoline 16D-3237 Lead in Gasoline by AA 16D-3246 Sulfur in Petroleum Gas by Oxidative Microcoulometry 17D-3340 Li & Na in Lubricating Greases by Flame Photometer 17

    D-3524 Diesel Fuel Analysis by GC 17D-3605 Trace Metal in Gas Turbine Fuels by AA 17D-3606 Aromatics in Gasoline by GC 18D-3610 Total Co Analysis by Potentiometric Titration 18D-3710 Boiling Range by GC 20D-3798 p-Xylene Analysis by GC 20D-3831 Manganese in Gasoline by AA 20D-4059 PCB Analysis by GC 21D-4110 Ion Chrom 76D-4291 Ethylene Glycol by GC 21D-4294 Sulfur by ED-XRF 7-11, 21D-4377 Water in Liquid Petroleum Products 5, 21D-4420 Aromatics in Gasoline by GC 22D-4628 Wear Metals in Lube Oil 22D-4629 Nitrogen by Chemiluminescence 23D-4815 Oxygenates in Gasoline by GC 24D-4927 Wear Metals and Additives by WD-XRF 25,63D-4928 Water in Liquid Petroleum Products 6, 25

    D-4929 Chlorine in Crude Oil by Microcoulometry 25D-4951 Wear Metals and Additives by ICP 26D-5056 Trace Metals in Petroleum Coke by AA 26D-5059 Lead in Gasoline by X-Ray Spectroscopy 27D-5134 Petroleum Naphthas through n-Nonane by GC 27D-5184 Al and Si by ICP-AES & AA 28D-5185 Wear Metals and Additives by ICP 28D-5186 Aromatics by SFC 28D-5188 Vapor - Liquid Ratio Temperature 29D-5191 Vapor Pressure Standards 29D-5307 Boiling Range Distribution of Crude Petroleum by GC 29

    D-2622 Sulfur by XRF 10D-3120 Sulfur by Oxidative Microcoulometry 10, 17D-3246 Sulfur in Petro Gas by Oxidative Microcoulometry 6-11D-4294 Sulfur by ED-XRF 10D-5453 Sulfur by Ultra Violet Fluorescence 6-11, 31D-5623 Sulfur Compounds by Sulfur Selective Detection 38D-6334 Sulfur in Gasoline by Wavelength WD-XRF 6-11D-6445 Sulfur in Gasoline by ED-XRF 6-11

  • 5/25/2018 Petroleum Standards

    4/116

    Use the AccuStandard Cross

    Reference Tables to Match

    various International

    Methods for known

    Petrochemical analysis.

    Tables Generated from(a) R.A. Nadkarni, Guide to ASTM Test Methods for the Analysis of Petroleum Products and Lubricants, Manual 44(200), ASTM West Conshohocken, PA(b) Annual Book of ASTM Standards 2000, Volumes 05.01 to 05.05

    ANALYSIS ASTM IP ISO DIN JIS AFNOR PAGE

    Tag Flash Point D-56 51411 K 2580 M07-003 3

    Distillation D-86 123 3405 51751 K 2254 M07-002 3

    COC Flash Point D-92 36 2592 51376 K 2265 T60-118 3

    PMCC Flash Point D-93 34 2719 51758 K 2265 M07-019 3

    Kinematic Viscosity D-445 71-1 3104 51562 K 2283 T60-100 3

    Aniline Point D-611 2 2977 51775 M07-021 4

    Hydrocarbon Types by FID D-1319 156 3837 51791 K 2536 M07-024 4

    Water (Karl Fischer) D-1744 6296 T60-154 5

    Freezing Point D-2386 16 3013 51421 K 2276 M07-048 5

    Cloud Point D-2500 219 3015 51597 K 2269 T60-105 5

    Sulfur by XRF D-2622 51400T6 K 2541 10

    Boiling Range By GC D-2887 3924 14

    Sulfur by Oxidative Microcoulometry D-3120 16591 16

    Lead by AAS D-3237 428 16

    Sulfur by Oxidative Microcoulometry D-3246 373 M07-052 10

    Metals by AA D-3605 413 8691 51790T3 17

    Benzene by GC D-3606 425 18

    Sulfur by ED-XRF D-4294 336 8754 M07-053 21

    Water (Karl Fischer) D-4377 356 10336 5

    Metals by AA D-4628 308 51391T1 22

    Nitrogen by Chemiluminescence Detection D-4629 379 M07-058 23

    Metals by WD-XRF D-4927 407 51391T2 25, 63

    Water (Karl Fischer) D-4928 386 10337 5, 25

    Lead in Gas By X-Ray D-5059 228 27

    Vapor Pressure D-5191 394 M07-079 29, 32

    Oxygenates D-5599 408 34-36

    Cloud Point D-5771 444 52

    Cloud Point D-5772 445 52

    Cloud Point D-5773 446 52

    Freezing Point D-5901 434 53

    Auto-Freeze Point D-5972 435 53

    Hydrocarbons Automatic D-6379 436 57

    Hydrocarbons Automatic NEW D-6591 391 57

    Metals 14597 62

    Fully AccreditedFor over 17 years

    AccuStandard has been the

    Leader in the Chemical

    Standards Industry in both

    Organic and Inorganic

    products. AccuStandard is

    ISO 9001:2000 registered

    and a NIST/NVLAP

    accredited Proficiency

    Testing provider (NVLAP

    Code 200389-0).

    ISO 9001:2000Certificate Number: 31692

    MEMBER

    Cross Reference Table Sorted by ASTM Method

    II

    This is a partial list of Standards available for ASTM Methods

    Member

    AccuStandard is an active member in ASTM and

    strives to keep abreast of ASTM method revisions.

    If our listed formulation does not meet the most

    recent method revision, please contact Technical

    Support, ext. 117 for an updated product.

  • 5/25/2018 Petroleum Standards

    5/116

    Milligram to Kilogram Scale Glassware

    Equipment to work under N2/Ar

    Flash and Liquid Solid Phase Chrom. (mg to 2 kg)

    Preparative TLCBuchi Rotary Evaporator

    Vacuum Drying Oven

    Parr Pressure Reactor (high pressure reaction, hydrogenation)

    Distillation Equipment - High Vacuum Distillation, Molecular

    Distillation (Kugelrohr), Spinning Band Columns,

    Packed and Vigreaux columns

    Melting Point Apparatus

    pH meter

    Viscometer

    Centrifuge

    Lab Resources

    Analytical Capabilities

    Inorganic (ICP)PE Optima 3000

    Spectro FMD-07

    Organics

    GCs: (6) HP 5890 Series II, FID, NPD, ECD all withauto injectors

    GC/MS: (3) HP 5971A

    HP 5971A with OI Analytical Purge & Trap

    PE Q-Mass 910

    HPLC: Varian 5000 with Applied Bioscience Fluoresce

    detector and HP auto injector

    Sulfur (low level)XOS (XRF) with monochromatic wavelength disperser

    Antek 9000 Series (UVF)

    MiscellaneousIon Chromatograph, Waters 600E with

    Conductivity detector 431, Alltech 335 Ion

    Suppressor

    Automatic Polarimeter, Zuzi W22

    Karl Fischer Titrator

    Analytical Instruments

  • 5/25/2018 Petroleum Standards

    6/116

    5 Ways to Searche-Standards is the Fastest, Most Comprehensive Search Engineavailable and contains over 30,000 products.

    Search by:

    Catalog Number

    Single or Multiple Components,

    Method (EPA, ASTM, etc.)

    Chemical Category (Organic, Inorganic, Petroleum, etc.)

    Other Companys Part Number

    Log on to www.accustandard.com and see how easy it is.

    Easy Ordering 24/7Find It Fast...simply search for a product, select it for purchase &

    click - it's that easy! Discounts may apply to online orders, see

    details on website.

    On-Line Custom ServicesAccuStandard specializes in synthesizing chemicals of high purity

    to be used as reference standards, and offers custom synthesis

    capability for milligram to kilogram batches. If you can't find the

    specific standard you need, we can prepare Custom Formulations

    and Custom Packaging for both Organic and Inorganic needs.See our Website for more info.

    There is an easier way to get Chemical Reference Standarde-Standards

    from AccuStandard.com

    Over 30,000 Standards

    just a click away

    IV

    On-Line Ordering

    AccuStandard offers over 30,000 different standards, and if you can't find the specific standard you need, we will prepare a cus

    formulation. Our custom organic and inorganic standards are a fast, economical way to address your unique requirements. To

    make an inquiry for Custom Quotes visit our website.

    You can also Email your requirements to [email protected] or Fax us at 203-786-5287. Please include the follow

    information: List of analytes and concentrations, Solvent or matrix, Quantity required (milliliters), Packaging unit size (millilit

    per ampule, bottle, or vial).

    Quality Control Options1. Gravimetric/Volumetric Certification: Each standard is measured gravimetrically and then QCed instrumentally (where

    available). Every component in the standard is guaranteed to be within 0.5% of the requested value unless otherwise stated.

    solutions are made up to volume using class A glassware. A certificate comes with each standard and documents the gravimetr

    values used.

    2. Quantitative Validation: Full QA/QC method includes extended GC analysis using both internal and calibration standards pl

    statistical analysis. A data package is provided containing analytical and gravimetric data (Organic customs only).

    Also available: OEM Standards - Privately labeled standards manufactured and tested to your specifications.

    Custom Formulations

  • 5/25/2018 Petroleum Standards

    7/116

    AccuPetroCheck Consensus Value QC Standards

    AccuPetroTest Gasoline

    AccuPetroTest Gasoline

    AccuPetroTest

    Fax 203-786-5287 Toll Free 800-442-5290 / 203-786-5290 Website www.accustandard.com

    QC

    Technical Note

    Low Sulfur QC SampleSBPT-LSGAS $ 25 / 2 x 15 mL

    Parameter Method Approx. RangeSulfur D-5453 0 - 50 g/g

    Olefin QC SampleSBPT-OLEFINSFC $ 25 / 2 x 15 mL

    Parameter Method Approx. RangeTotal Olefins D-6550 1 - 40 Vol.%

    AccuPetroCheck QC StandardsTwo of the fuels are available asAccuPetroCheck Consensus Value QC

    Standards. The AccuPetroCheck CARB a

    Conventional gasoline reference materials ha

    all parameters listed on the certificate with t

    Consensus Values and the regression equatio

    for reproducability. Use of these Reference

    Materials improve the quality of laboratory

    results. The Consensus Values listed reflect

    initial statistical treatment of the data at the

    the catalog was published. The actual certif

    provided with the AccuPetroCheck QC stan

    will have the accepted Consensus Value base

    statistical treatment of the data.

    Sulfur Single Blind AccuPetroTestAlternative Matrices StandardsAccuStandard has manufactured a number o

    Diesel and White Mineral Oil QC products

    containing a gravimetrically prepared amou

    Sulfur. Use of these alternative matrix mate

    can provide further evaluation of the QA/QC

    process in the laboratory. Two samples will

    sent for the test parameter and a separate sea

    envelope containing the gravimetrically prep

    sulfur values is also provided. The secondsample is for repeatability testing or for use

    future QA/QC reference.

    Sulfur in White Mineral Oil QCStandardSBPT-SWMO $ 25 / 2 x 15 mL

    Parameter Approx. RangeSulfur 20 - 11000 g/g

    See ASTM Methods D-2622, D-3120,D-3246-92, D-4294, D-5453 for SulfurCalibration Standards

    Sulfur in Diesel Fuel QC StandardSBPT-SDF $ 25 / 2 x 15 mL

    Parameter Approx. RangeSulfur 20 - 11000 g/g

    See ASTM Methods D-2622, D-3120, D-3246-92,D-4294, D-5453 for Sulfur Calibration Standards

    Conventional Gasoline QCStandardASTM-FUEL-QCS-02-PAK $ 60 / 5 x 15 mL

    Parameter Method Value Conc.Total Aromatics D-1319 34.6 Vol.%Total Olefins D-1319 12.4 Vol.%Total Saturates D-1319 62.8 Vol.%Sulfur D-2622 0.0338 Wt.%Sulfur D-4294 0.0368 Wt.%Sulfur D-5453 317.36 g/gSulfur D-6344 338.78 g/gBenzene D-5769 0.55 Vol.%Toluene D-5769 5.53 Vol.%Total Aromatics D-5769 32.51 Vol.%

    Benzene D-6277 0.52 Vol.%Total Olefins D-6550 12.4 Vol.%

    CARB Low Sulfur RFG QCStandardASTM-FUEL-QCS-01-PAK $ 60 / 5 x 15 mL

    Parameter Method Value Conc.Total Aromatics D-1319 24.5 Vol.%Total Olefins D-1319 5.3 Vol.%Total Saturates D-1319 58.3 Vol.%Sulfur D-2622 0.0057 Wt.%Sulfur D-4294 0.0078 Wt.%Sulfur D-5453 55.76 g/gSulfur D-6344 59.31 g/gBenzene D-5769 0.80 Vol.%Toluene D-5769 4.92 Vol.%Total Aromatics D-5769 23.42 Vol.%

    Benzene D-6277 0.78 Vol.%Total Olefins D-6550 5.3 Vol.%

    AccuPetroCheck and AccuPetroTest Real World Gasoline QC StandardsIn cooperation with ASTM D-02 subcommittee 3 and 4, AccuStandard ampulled 21 Real World gasoline reference fuels. Consensus Values

    been determined for these reference fuels by various ASTM Round Robins to provide Petrochemical Laboratories with a source of well

    characterized gasoline standards for use in QA/QC applications and as Single Blind test samples over an extended period of time. As new A

    D-02.03 and D-02.04 Test methods are promulgated they require mandatory Quality Control testing of real world samples. AccuStandard

    PetroTest & PetroCheck standards are being successfully used to achieve these new Quality Control requirements.

    Quality Control Standards

    Quality Control Standardscontinue on next page

    Real

    This comprehensivesingle blind gasoline QCsample tests for moreparameters from a singlesample. The actualgasoline sample will haveconsensus values listedon the datasheet that fallwithin the range listed foreach parameter.

    Comprehensive Single Blind Gasoline QC SampleSBPT-COMP $ 50 / 2 x 15 mL

    Parameter Method Approx. Range Conc.Total Aromatics D-1319 8 - 60 Vol.%Total Olefins D-1319 1 - 40 Vol.%Total Saturates D-1319 30 - 80 Vol.%Sulfur D-2622 0.0001 - 0.0930 Wt.%Sulfur D-4294 0.0016 - 0.0930 Wt.%Sulfur D-5453 0.5 -500 g/gSulfur D-6344 1.0 - 1000 g/gBenzene D-5769 0.1 - 2.0 Vol.%Toluene D-5769 1.0 - 15 Vol.%Total Aromatics D-5769 8 - 60 Vol.%Benzene D-6277 0.1 - 2.0 Vol.%Total Olefins D-6550 1 - 40 Vol.%

  • 5/25/2018 Petroleum Standards

    8/116

    2 Quality System is Certified to comply with the International ISO 9001 Quality Standard

    QC

    QC

    Quality Control Standards

    Conducting a Petrochemical Round Robin for a new ASTM method?

    Select AccuStandard to prepare the necessary samples for the Round Robin studyAccuStandard has packaged for ASTM committee D-02 various select groups of gasoline fuels and hydrocarbon products for use in various

    Round Robin studies.

    Large Sample OfferingAccuStandard was selected by ASTM committee D-02 to fill, seal and package an initial set of 21 different types of Round Robin Gasolines.

    Each gasoline was selected due to its unique properties. These unique properties will be determined by various ASTM methods under evalua

    through ASTM subcommittees. AccuStandard has expanded this offering with additional materials blended for other ASTM Round Robins.

    FlexibilityUse the original 21 gasoline samples to conduct a Round Robin and we can label the samples appropriately to protect the integrity of the Rou

    Robin. In addition, we can easily add additional samples to your specific Round Robin study to expand the scope of the method for differen

    matrices, concentrations or instrument types.

    AccuPetroTest Gasoline QCAccuPetroTest Single BlindStandardsPetrochemical laboratories looking to

    the performance of the laboratory for

    specific parameter can order the Sing

    Blind AccuPetroTest sample for the

    parameter of interest. Two real worl

    gasoline samples will be sent for the parameter requested and a separate s

    envelope containing the determined

    Consensus Value is also provided. T

    second sample is for repeatability tes

    or as a future QA/QC reference.

    Petro PT Samples

    Oxygenate PT SampleWith MtBE contamination problems in drinking water, numerous states arenow requiring certification for Oxygenate monitoring. Join AccuStandardsnext study for Oxygenate analysis. Our timely PT schedule easily allowsyour lab to be proactive in new regulatory requirements. The analytes inthe standard and the PT sample have been drawn from the California listof known prevalent oxygenates in gasoline. These new Oxygenate PTsamples and standards allow your Lab to:

    Expand testing capabilities Generate new testing revenue

    Eliminate standard preparation Easily combine with otherAccuStandard Volatile standards

    ***

    WP-PT Oil, Grease & TPHIPE-OILG-001-AS $ 32 / 5 mLIPE-OILG-001-AT $ 32 / 5 mLIPE-OILG-001-AV $ 32 / 5 mLSample conc. after prepContains 2 analytes listed below

    Analyte List Sample rangeTotal Oi l & Grease 5-100 mg/LTPH 5-100 mg/L

    Oil and GreaseWC-OILG-10X-1 $ 45 / 100 mL1000 g/mL Total Oil and Grease in n-Propanol

    Contains 500 g/mL vegetable oil and 500 g/mL of petroleum oil.Shake well before use.

    Suggested Calibration Standard

    Olefins QC SampleSBPT-OLEFIN $ 25 / 2 x 15 mL

    Parameter Method Approx. RangeTotal Aromatics D-1319 8-60 Vol.%Total Olefins D-1319 1 - 40 Vol.%

    Total Saturates D-1319 30-80 Vol. %See ASTM Method D-1319 for Sulfur CalibrationStandards

    Sulfur QC SampleSBPT-SGAS $ 25 / 2 x 15 mL

    Parameter Method Approx. RangeSulfur D-2622 0.0001 - 0.0930 Wt.%Sulfur D-4294 0.0016 - 0.0930 Wt.%

    Sulfur D-5453 4.0 - 500 g/gSulfur D-6344 1.0 - 1000 g/g

    See ASTM Methods D-2622, D-3120, D-3246-92,D-4294, D-5453 for Sulfur Calibration Standards

    Benzene/Toluene QC SampleSBPT-BENZ $ 25 / 2 x 15 mL

    Parameter Method Approx. RangeBenzene D-5769 0.1 - 2.0 Vol.%Toluene D-5769 1.0 - 15 Vol.%

    See ASTM Methods, D-3606, D-5580-95, D-5769-95for Benzene Calibration Standards

    Aromatics QC SampleSBPT-AROM $ 25 / 2 x 15 mL

    Parameter Method Approx. RangeTotal Aromatics D-5769 8 - 60 Vol.%

    See ASTM Methods, D-3606, D-5580-95, D-5769-95for Benzene Calibration Standards

    SUFFIX KEY"AS" = Formal PT Study"AT" = Pre-Test"AV" = Values Included

    This PT sample can be used by gravimetric oil and greasemethods. In addition, it can also be used for TPH analysis bgravimetric methods including the EPA method 1664. Thesample contains real world material commonly found at

    petroleum containment sites.

    Technical Note

    MTBETAME

    ETBEDiisopropylether

    WS-PT OxygenatesOPE-OXY-001-AS $ 47 / 2 mLOPE-OXY-001-AT $ 47 / 2 mL

    OPE-OXY-001-AV $ 47 / 2 mLSample conc. after prep 5.0-50 g/LContains 4 analytes listed below

    NEW

    TAME (2000 g/mL)t-Butanol (10000 g/mL)

    Oxygenate Gasoline Additive StandardOGAD-001 $ 30 / 1 x 1 mLOGAD-001-PAK SAVE 20% $ 120 / 5 x 1 mLAt stated conc. in MeOH 5 comps.

    MtBE (2000 g/mL)ETBE (2000 g/mL)Isopropyl ether (2000 g/mL)

    Suggested Calibration Standard

    ASTM Round Robin

    &

    PT

    Samples

    Lab Code 200389-0

    * Designed for NELAC/CA Indicates that theses analyteincluded in the NVLAP Scope oAccreditation, Lab Code 20038

    NEW

    **

    *

  • 5/25/2018 Petroleum Standards

    9/116

    ASTM D-56, D-92, D-93 Flash Point Standards

    Fax 203-786-5287 Toll Free 800-442-5290 / 203-786-5290 Website www.accustandard.com

    Memb

    Certified Flash Point StandardsThe reference material is a stable, pure hydrocarbon with a method specific flash pointdetermined by an inter-laboratory study using the ASTM Method # referenced.

    Cat. No. ASTM # Nominal Flash Point Price / Unit

    ASTM-P-133-01 PMCC D93 65C $ 175 / 250 mLASTM-P-133-02 PMCC D93 134C 130 /250 mLASTM-P-133-03 COC D92 138C 130 /250 mLASTM-P-133-04 TCC D56 67C 175 /250 mL

    Physical Properties

    Cat. No. ASTM # Nominal Flash Point Price / Unit

    ASTM-P-132-01 PMCC D93 65C $ 110 /250 mLASTM-P-132-02 PMCC D93 93C 110 / 250 mLASTM-P-132-03 COC D92 200C 110 / 250 mLASTM-P-132-04 COC D92 230C 110 / 250 mL

    ASTM D-86 Synthetic Distillation Standard

    The automatic distillation apparatus duplicates the distillation conditions of the manual method. Theincreased reliance on electronic control requires an independent standard to verify that the apparatus isperforming correctly. This synthetic blend of hydrocarbons boil in the temperature range specified inASTM D-86 distillation groups 1 and 2, and a fuel oil that meets the group 4 criteria.

    The group 1 and 2 standards cover the boiling range 129 - 368 F (54 - 187 C) and are verified byconsensus analysis with twelve refinery laboratories. The group 4 standard covers the range from 410 -670 F (210 - 355 C). Products are packaged in convenient sizes to meet your laboratory sampleanalysis demands.

    Verified by consensus analysis using ASTM Method # referenced

    Meth

    Cat. No. Group Description Price / Unit

    ASTM-P-126-01 1, 2 Synthetic Distillation Standard $ 160 /500 mLASTM-P-126-SET 1, 2 Synthetic Distillation Standard 290 /2 x 500 mL

    ASTM-P-127-01 4 Distillation Standard 160 /250 mLASTM-P-127-02 4 Distillation Standard 290 /500 mL

    Oils are tested inaccordance withASTM D-445

    Technical NoteAlso see Cloud PointStandards used for ASTMMethod D-2500 on page 5

    Standards of Interest

    ASTM D-445 Viscosity Calibration Standards

    ASTM D-92 & Flash & Fire Points by Cleveland Open Cup (COC) &

    ASTM D-93 Flash Point by Pensky Martin Closed Cup (PMCC)

    See Method D-56 on this page for the comprehensive line of flash point standards

    Cat. No. Viscosity @ 40 C Price / Unit

    ASTM-P-128-01 4 Cst $ 60 /500 mLASTM-P-128-02 7 Cst 60 /500 mLASTM-P-128-03 19 Cst 60 /500 mLASTM-P-128-04 61 Cst 60 /500 mLASTM-P-128-05 180 Cst 60 /500 mL

    ASTM-P-128-06 520 Cst 60 /500 mL

    Originally designed forASTM D-56-98a,D-92-98a, D-93-99b

    Originally designed forASTM D-86-99a

    Originally designed forASTM D-445-97

  • 5/25/2018 Petroleum Standards

    10/116

    4 Quality System is Certified to comply with the International ISO 9001 Quality Standard

    Member

    ASTM

    The following set of standardhave been prepared for thedetermination of Aromatics,Olefins, Oxygenates and

    Saturates in petroleum fractioby Fluorescent IndicatorAdsorption (FIA) IP designat156/95.

    The final certificate for the Fcalibration curve lists not onlthe volume percents for thehydrocarbon types, but also individual volume percents foeach analyte in the functionagroup.

    To further assist thePetrochemist, the weight fracfor each hydrocarbon type aindividual analyte is listed on

    final certificate. By providingindividual weights thePetrochemical chemist can uthe FIA standards for othertypes of instrumentationmeasuring these Petroleumfractions.

    Technical Note

    ASTM D-611 (Reapproved 1998) Aniline Point Standards

    ASTM D-1015 Freezing Points of High Purity Hydrocarbons

    See Method D-2386 page 5 for AccuStandards new line of Freezing Point Standards

    Method 611

    1015

    1319

    The accuracy of automated aniline point apparatus can be verified using a range of standards whoseaniline points are determined using ASTM D-611 (Method A) and ASTM D-611 (Method E). Standards arepackaged in 20 mL ampules in an inert atmosphere.

    Physical Properties

    Cat. No. Nominal Aniline Point Price / Unit

    D-611-SET Set include 5 Standards listed below $ 90 / 5 x 20 mLAniline Point Verification SetMethod 611(A)

    D-611-01 0C 20 mLD-611-02 30C 20 mLD-611-03 55C 20 mLD-611-04 68C 20 mLD-611-05 94C 20 mL

    Cat. No. Nominal Aniline Point Price / Unit

    D-611E-SET Set include 3 Standards listed below $ 90 / 3 x 20 mLAniline Point Verification SetMethod 611(E)

    D-611E-01 43C 20 mLD-611E-02 62C 20 mLD-611E-03 77C 20 mL

    Cat. No. Price / Unit

    ASTM-P-134-PAK Pure Aniline $ 30 / 5 x 15 mL

    Std. 1 Std. 2 Std. 3 Std. 4 Std. 5 Std. 6 Std. 7

    Target Vol. % Vol. % Vol. % Vol. % Vol. % Vol. % Vol. %

    Total Olefins 2.0 4.0 5.0 6.0 8.0 10.0 12.0Total Paraffins 57.0 55.0 52.0 51.0 45.0 45.0 40.0Total Aromatics 23.0 24.0 25.0 26.0 29.0 28.0 30.0Total Oxygenate 18.0 17.0 18.0 17.0 18.0 17.0 18.0

    ASTM D-1319 Calibration Standards by Fluorescent Indicator Adsorption FIA

    For routine purposes pureAniline is packaged in ampuunder dry nitrogen. Thisminimizes the risk of oxidatio

    Technical Note

    For the mandatory real world QC samplesstipulated in the Method, see page 1-2

    Standards of Interest

    Vol. %1-Heptene 33.3

    Vol. %1-Pentene 33.32,3-Dimethyl-2-butene 33.3

    FIA Olefin StandardFIA-OLE $ 40 / 1 x 1 mLFIA-OLE-5ML SAVE 40% $ 120 / 1 x 5 mL

    3 comps.

    mix ratiom-Xylene 161,2,4-Trimethylbenzene 81,3,5-Trimethylbenzene 81,2,4,5-Tetramethylbenzene 4Naphthalene 4

    mix ratioBenzene 4Toluene 32Ethylbenzene 8p-Xylene 8o-Xylene 8

    Vol. %2,3-Dimethylpentane 14Isooctane 16n-Octane 14n-Decane 7

    Vol. %n-Pentane 8n-Hexane 9Cyclohexane 15n-Heptane 14

    FIA Aromatic StandardFIA-ARO $ 30 / 1 x 1 mLFIA-ARO-5ML SAVE 33%$ 100 / 1 x 5 mL

    10 comps.

    FIA Paraffin StandardFIA-PAR $ 30 / 1 x 1 mLFIA-PAR-5ML SAVE 33% $ 100 / 1 x 5 mL

    8 comps.

    D-1319

    Meets

    EPAGuidelines

    forRFG

    Analysis

    Olefin FIA Calibration CurveFIA-CAL-SET $ 300 / Set of 7 x 1 mL

    Originally designed forD-611-82

    Originallydesigned forD-1319-99

  • 5/25/2018 Petroleum Standards

    11/116

    ASTM D-1744, E-1064, D-4377 Water in Liquid Petroleum Products by

    D-4928, D-6304 Karl Fischer

    Fax 203-786-5287 Toll Free 800-442-5290 / 203-786-5290 Website www.accustandard.com

    Memb

    Many ASTM Petrochemicalmethods and specificationsreference using QA/QCstandards for water contentmeasurements. AccuStandahas formulated a compreherange of water standardspackaged in convenient sizemeet the various referencedmethods.

    Technical Note

    ASTM D-2386 Freezing Point Calibration Standards

    ASTM D-2500 Cloud Point Calibration Standards

    Meth

    Verified by consensus analysisASTM Method D-2386

    Technical Note

    Cat. No. Description Price / Unit

    KF-0.6X-5ML-VAP Water content 60 g/g $ 65 /10 x 5 mLKF-1X-2ML-VAP Water content 100 g/g 40 /10 x 2 mLKF-1X-5ML-VAP Water content 100 g/g 45 /10 x 5 mLKF-1X-20ML-PAK Water content 100 g/g 50 /5 x 20 mL

    KF-10X-2ML-VAP Water content 1000 g/g 40 /10 x 2 mLKF-10X-5ML-VAP Water content 1000 g/g 45 /10 x 5 mLKF-10X-20ML-PAK Water content 1000 g/g 50 /5 x 20 mL

    KF-50X-2ML-VAP Water content 5000 g/g 40 /10 x 2 mLKF-50X-5ML-VAP Water content 5000 g/g 45 /10 x 5 mLKF-50X-20ML-PAK Water content 5000 g/g 50 /5 x 20 mL

    Value Added Paks (Cat. No.sending in -VAP) providemultiple single units packagedtogether for both greaterstability and cost savings.

    Physical Properties

    Cat. No. Nominal Freezing Point Price / Unit

    ASTM-P-129-01 - 50 C $ 110 /250 mL

    ASTM-P-129-02 - 45 C 110 /250 mL

    Cat. No. Cloud Point, Approx. Value Price / Unit

    ASTM-P-131-01 + 5 C $ 110 /250 mLASTM-P-131-02 - 2 C 110 /250 mLASTM-P-131-03 - 10 C 110 /250 mLASTM-P-131-04 - 15 C 110 /250 mLASTM-P-131-05 - 20 C 110 /250 mL

    Standards are available for coulometric Karl Fischer titrations and are packaged in 2 mL, 5 mL, and 20 mL ampules insets of 5 and 10. The following concentrations are available:

    Originally designed for

    D-2386-97

    Verified by consensus analysis ASTM Method D-2500

    Technical NoteOriginally designed forD-2500-00

  • 5/25/2018 Petroleum Standards

    12/116

    6 Quality System is Certified to comply with the International ISO 9001 Quality Standard

    ASTM

    SULFUR

    Low Sulfur Standards on following pages

    Sulfur StandardsASTM Methods for

    Sulfur

    Analysis

    D-2622-98, D-3120-96, D-3246-96, D-4294-98, D-5453-00, D-6334-98, D-6445-99 & Proposed ASTM Sulfur MethAccuStandard offers the Petroleum Industry the most complete line of calibration standards designed for todays Proposed &

    Promulgated test methods for Sulfur analysis. These calibration standards are designed specifically for the analysis of Sulfur in

    wide variety of matrices such as #2 diesel fuel, white mineral oil, kerosene, gasoline, crude oil & residual oil.

    Traceability, Quality and Certification

    All Sulfur standards are manufactured from the highest quality raw materials, including well characterized starting materials &lowest sulfur matrices available from the Petrochemical market. All standards are manufactured on a weight/weight basis usin

    balances that are calibrated and verified daily against reference mass standards directly traceable to NIST under test No.

    822/254480. The concentration of these working level Sulfur standards have established traceability links to NIST SRMs whe

    available.

    Convenient PackagingSince applicable concentration ranges will vary based on the instrumentation used & the nature of the sample the standards can

    ordered as complete sets, individual bottles, or Ready-to-Aspirate AccuShots.

    AccuShots... Packaged to improve analytical standard integrityAccuStandard is the first standard manufacturer to provide sulfur standards in convenient and Ready-to-Aspirate AccuShot 20

    sealed ampules. Each 20 mLAccuShot provides the necessary material for calibration curve development or daily QA/QC. B

    purchasing AccuShots the analytical chemist can open a fresh shot for each analysis which eliminates opening and pipettingrepeatedly from a stock bottle. This minimizes contamination and evaporation. These ship with no haz fee for additional savin

    ASTM D-5453

    Test to Low ppbSulfur

    Contact us for a copy of theSouthwest Research Institute

    D-5453 Fitness for Use Report

  • 5/25/2018 Petroleum Standards

    13/116

    Limits of Detection < 1 ppm

    Fast and easy sample preparation.

    Typical measurement time: 300 sec

    Dynamic range: 0-1000 ppm in one

    calibration.

    No sample conversion or reagents

    required.

    Exceptional signal-to-background

    provides high sensitivity for

    low-level sulfur fuels

    Analytical Capabilities

    X-Ray Optical Systems, Inc.15 Tech Valley DriveEast Greenbush, NY 12061Tel. 518-880-1500website: www.xos.com

    Monochromatic WDXRF Technology

    MWD XRF Sulfur Analyzerin Diesel and Gasoline Fuels

    XOS SINDIE AnalyzerX-Ray optics enable detection capability well

    beyond traditional XRF techniques. The

    same Monochromatic WD XRF technology

    of the SINDIE bench-top sulfur analyzer is

    available in an on-line sulfur analyzer.

    SULFURANALYSIS INULTRA LOW SULFUR FUELS

    Repeatability:1 ppm 0.5 ppm

    10 ppm 1.7 ppm

    100 ppm 5.3 ppm

    500 ppm 11.7 ppm

  • 5/25/2018 Petroleum Standards

    14/116

    8 Quality System is Certified to comply with the International ISO 9001 Quality Standard

    ASTM

    SULFUR

    Sulfur in

    Mineral Oil

    Diesel Fuel

    Sulfur in Light Weight Mineral Oil (20 cSt)Sulfur in Heavy Weight Mineral Oil (75 cSt)

    Individual Sulfur 1 -10 units 10 +unitsStandards 4 oz Bottle $ 55 ea $ 50 ea

    Sulfur StandardsASTM Methods

    AccuShots... Packaged to improve analyticalstandard integrity

    AccuStandard is the first standard manufacturer toprovide sulfur standards in convenient and Ready-to-Aspirate AccuShot 20 mL sealed ampules. Each 20 mLAccuShot provides the necessary material for calibrationcurve development or daily QA/QC. By purchasingAccuShots the analytical chemist can open a fresh shotfor each analysis which eliminates opening and pipettingrepeatadly from a stock bottle. This minimizescontamination and evaporation. These ship with no hazfee for additional savings.

    Ready-to-Use

    Individual Sulfur 1 -10 units 10 +unitsStandards 4 oz Bottle $ 55 ea $ 50 ea

    8

    ASTM Methods Sulfur in Mineral Oil

    Sulfur conc. calculated from % sulfur in di-n-butyl sulfide

    Technical Note

    Sulfur in Ready-to-UseConcentration White Mineral Oil Sulfur AccuShots

    g/g Wt. % Cat. No. Cat. No.Blank 0.000 SWMO-BL-4 SWMO-BL-SHOT

    100 0.010 SWMO-1X-4 SWMO-1X-SHOT200 0.020 SWMO-2X-4 SWMO-2X-SHOT300 0.030 SWMO-3X-4 SWMO-3X-SHOT400 0.040 SWMO-4X-4 SWMO-4X-SHOT500 0.050 SWMO-5X-4 SWMO-5X-SHOT750 0.075 SWMO-7.5X-4 SWMO-7.5X-SHOT

    1,000 0.10 SWMO-10X-4 SWMO-10X-SHOT1,500 0.15 SWMO-15X-4 SWMO-15X-SHOT2,000 0.20 -------------------- --------------------------3,000 0.30 SWMO-30X-4 SWMO-30X-SHOT4,000 0.40 -------------------- --------------------------5,000 0.50 SWMO-50X-4 SWMO-50X-SHOT7,000 0.70 SWMO-70X-4 SWMO-70X-SHOT

    10,000 1.00 SWMO-100X-4 SWMO-100X-SHOT

    15,000 1.50 SWMO-150X-4 SWMO-150X-SHOT20,000 2.00 SWMO-200X-4 SWMO-200X-SHOT30,000 3.00 SWMO-300X-4 SWMO-300X-SHOT40,000 4.00 SWMO-400X-4 SWMO-400X-SHOT50,000 5.00 SWMO-500X-4 SWMO-500X-SHOT60,000 6.00 SWMO-600X-4 SWMO-600X-SHOT

    Set of above SWMO-CAL-SET-4 Each AccuShot productCat. No.s 19 x 4 oz. $ 850 contains 5 x 20 mL

    ampules at the statedconc. for $ 60Individual Sulfur 1 -10 units 10 +units

    Standards 4 oz Bottle $ 55 ea $ 50 ea

    Sulfur in Ready-to-UseConcentration White Mineral Oil Sulfur AccuShots

    g/g Wt. % Cat. No. Cat. No.Blank 0.000 SWMO-LT-BL-4 SWMO-LT-BL-SHOT

    100 0.010 SWMO-LT-1X-4 SWMO-LT-1X-SHOT200 0.020 SWMO-LT-2X-4 SWMO-LT-2X-SHOT300 0.030 SWMO-LT-3X-4 SWMO-LT-3X-SHOT400 0.040 SWMO-LT-4X-4 SWMO-LT-4X-SHOT500 0.050 SWMO-LT-5X-4 SWMO-LT-5X-SHOT750 0.075 SWMO-LT-7.5X-4 SWMO-LT-7.5X-SHOT

    1,000 0.10 SWMO-LT-10X-4 SWMO-LT-10X-SHOT1,500 0.15 SWMO-LT-15X-4 SWMO-LT-15X-SHOT2,000 0.20 -------------------- --------------------------3,000 0.30 SWMO-LT-30X-4 SWMO-LT-30X-SHOT4,000 0.40 -------------------- --------------------------5,000 0.50 SWMO-LT-50X-4 SWMO-LT-50X-SHOT7,000 0.70 SWMO-LT-70X-4 SWMO-LT-70X-SHOT

    10,000 1.00 SWMO-LT-100X-4 SWMO-LT-100X-SHOT

    15,000 1.50 SWMO-LT-150X-4 SWMO-LT-150X-SHOT20,000 2.00 SWMO-LT-200X-4 SWMO-LT-200X-SHOT30,000 3.00 SWMO-LT-300X-4 SWMO-LT-300X-SHOT40,000 4.00 SWMO-LT-400X-4 SWMO-LT-400X-SHOT50,000 5.00 SWMO-LT-500X-4 SWMO-LT-500X-SHOT60,000 6.00 SWMO-LT-600X-4 SWMO-LT-600X-SHOT

    Set of above SWMO-LT-CAL-SET-4 Each AccuShot productCat. No.s 19 x 4 oz. $ 850 contains 5 x 20 mL

    ampules at the statedconc. for $ 60

    ASTM Methods Sulfur in #2 Diesel FuelSulfur in Ready-to-Use

    Concentration #2 Diesel Fuel Sulfur AccuShots

    g/g Wt. % Cat. No. Cat. No.Blank 0.000 SDF-BL-4 SDF-BL-SHOT

    100 0.010 SDF-1X-4 SDF-1X-SHOT200 0.020 SDF-2X-4 SDF-2X-SHOT300 0.030 SDF-3X-4 SDF-3X-SHOT400 0.040 SDF-4X-4 SDF-4X-SHOT500 0.050 SDF-5X-4 SDF-5X-SHOT750 0.075 SDF-7.5X-4 SDF-7.5X-SHOT

    1,000 0.10 SDF-10X-4 SDF-10X-SHOT1,500 0.15 SDF-15X-4 SDF-15X-SHOT2,000 0.20 ------------- -------------3,000 0.30 SDF-30X-4 SDF-30X-SHOT4,000 0.40 ------------- -------------5,000 0.50 SDF-50X-4 SDF-50X-SHOT7,000 0.70 SDF-70X-4 SDF-70X-SHOT

    10,000 1.00 SDF-100X-4 SDF-100X-SHOT15,000 1.50 SDF-150X-4 SDF-150X-SHOT20,000 2.00 SDF-200X-4 SDF-200X-SHOT

    30,000 3.00 SDF-300X-4 SDF-300X-SHOT40,000 4.00 SDF-400X-4 SDF-400X-SHOT50,000 5.00 SDF-500X-4 SDF-500X-SHOT60,000 6.00 SDF-600X-4 SDF-600X-SHOT

    Set of above SDF-CAL-SET-4 Each AccuShot productCat. No.s 19 x 4 oz. $ 850 contains 5 x 20 mL

    ampules at the statedconc. for $ 60

    Cross Reference TableASTM IP ISO DIN JIS AFNOR sorted by

    ASTM Method see beginning of Catalog

    Sulfur Standards for ASTM D-2622, D-3120, D-3246, D-4294, D-5453, D-6334, D-6445 &Proposed ASTM Sulfur Methods

  • 5/25/2018 Petroleum Standards

    15/116

    Method ASTM

    For the mandatory reaworld QC samplesstipulated in the Methosee pages 1- 2.

    Standards of Intere

    Sulfur in Heavy Distillate Kerosene

    Sulfur StandardsASTM Methods

    Individual Sulfur 1 -10 units 10 +unitsStandards 4 oz Bottle $ 55 ea $ 50 ea

    Individual Sulfur 1 -10 units 10 +unitsStandards 4 oz Bottle $ 55 ea $ 50 ea

    ASTM Methods Sulfur in Kerosene

    Sulfur concentration

    calculated from % sulfin di-n-butyl sulfide.

    Technical Note

    Sulfur in Light Ready-to-UseConcentration Distillate Kerosene Sulfur AccuShots

    g/g Wt. % Cat. No. Cat. No.Blank 0.000 SK-BL-4 SK-BL-SHOT

    100 0.010 SK-1X-4 SK-1X-SHOT200 0.020 ---------------300 0.030 SK-3X-4 SK-3X-SHOT400 0.040 ---------------500 0.050 SK-5X-4 SK-5X-SHOT750 0.075 SK-7.5X-4 SK-7.5X-SHOT

    1,000 0.10 SK-10X-4 SK-10X-SHOT1,500 0.15 ---------------2,000 0.20 SK-20X-4 SK-20X-SHOT3,000 0.30 SK-30X-4 SK-30X-SHOT4,000 0.40 SK-40X-4 SK-40X-SHOT5,000 0.50 SK-50X-4 SK-50X-SHOT7,000 0.70 ---------------

    10,000 1.00 SK-100X-4 SK-100X-SHOT15,000 1.50 ---------------20,000 2.00 SK-200X-4 SK-200X-SHOT30,000 3.00 ---------------40,000 4.00 ---------------50,000 5.00 ---------------60,000 6.00 ---------------

    Set of above SK-CAL-SET-4 Each AccuShot productCat. No.s 12 x 4 oz. $ 500 contains 5 x 20 mL

    ampules at the statedconc. for $ 60

    Sulfur in HeavyConcentration Distillate Kerosene

    g/g Wt. % Cat. No.Blank 0.000 SK-HD-BL-4

    100 0.010 SK-HD-1X-4200 0.020 SK-HD-2X-4300 0.030 SK-HD-3X-4400 0.040 SK-HD-4X-4500 0.050 SK-HD-5X-4750 0.075 SK-HD-7.5X-4

    1,000 0.10 SK-HD-10X-41,500 0.15 SK-HD-15X-42,000 0.20 SK-HD-20X-43,000 0.30 SK-HD-30X-44,000 0.40 SK-HD-40X-45,000 0.50 SK-HD-50X-47,000 0.70 SK-HD-70X-4

    10,000 1.00 SK-HD-100X-415,000 1.50 SK-HD-150X-420,000 2.00 SK-HD-200X-430,000 3.00 SK-HD-300X-440,000 4.00 SK-HD-400X-450,000 5.00 SK-HD-500X-460,000 6.00 SK-HD-600X-4

    Set of above SK-HD-CAL-SET-4Cat. No.s 21 x 4 oz. $ 950

    Fax 203-786-5287 Toll Free 800-442-5290 / 203-786-5290 Website www.accustandard.com

    Sulfur StandardsASTM Methods

    Sulfur in Light Distillate Kerosene

    Sulfu

    Sulfur Standards for ASTM D-2622, D-3120, D-3246, D-4294, D-5453, D-6334, D-6445 &Proposed ASTM Sulfur Methods

  • 5/25/2018 Petroleum Standards

    16/116

    ASTM D-3120, D-3246 Sulfur Calibration Set

    ASTM D-2622, D-4294 Sulfur Calibration Standards ASTM D-2622, D-6334, Low Level SulfurD-6445 Calibration Standards

    ASTM D-2622, D-6334, Mid Level SulfurD-6445 Calibration Standards

    10 Quality System is Certified to comply with the International ISO 9001 Quality Standard

    ASTM

    SULFUR

    ASTM 2622-

    6445

    10 Quality System is Certified to comply with the International ISO 9001 Quality Standard

    For the mandatory real world QC samples stipulated in manyASTM Sulfur Methods, see page 1-2

    Standards of Interest

    Cat. No. Sulfur Conc. Sulfur Wt. % UnitSTP-BL-4 Blank 0.0 4 oz.STP-1X-4 10 g/g 0.001 4 oz.STP-2X-4 20 g/g 0.002 4 oz.STP-3X-4 30 g/g 0.003 4 oz.STP-5X-4 50 g/g 0.005 4 oz.STP-10X-4 100 g/g 0.010 4 oz.STP-20X-4 200 g/g 0.020 4 oz.STP-30X-4 300 g/g 0.030 4 oz.STP-40X-4 400 g/g 0.040 4 oz.STP-60X-4 600 g/g 0.060 4 oz.STP-100X-4 1000 g/g 0.10 4 oz.STP-200X-4 2000 g/g 0.20 4 oz.STP-300X-4 3000 g/g 0.30 4 oz.

    STP-CAL-SET $ 650 / set of 13 x 4 oz.In Isooctane Set contains the above 13 individual bottles

    Standards can be mixed for quantity discounts

    1 to 4 units $ 60 each per Sulfur Standard5 to 10 units $ 55 each per Sulfur Standardmore than 10 units $ 50 each per Sulfur Standard

    Standards can be mixed for quantity discounts

    1 to 4 units $ 60 each per Sulfur Standard

    5 to 10 units $ 55 each per Sulfur Standardmore than 10 units $ 50 each per Sulfur Standard

    Cat. No. Sulfur Conc. Sulfur Wt. % UnitD-2622-LL-200X-4 200 g/g 0.020 4 ozD-2622-LL-400X-4 400 g/g 0.040 4 ozD-2622-LL-600X-4 600 g/g 0.060 4 ozD-2622-LL-700X-4 700 g/g 0.070 4 ozD-2622-LL-800X-4 800 g/g 0.080 4 ozD-2622-LL-900X-4 900 g/g 0.090 4 ozD-2622-LL-1100X-4 1100 g/g 0.110 4 ozD-2622-LL-1200X-4 1200 g/g 0.120 4 oz

    Well characterized Thiophene & 2-Methyl thiophene are usedin a low sulfur Isooctane/Toluene matrix for this calibration set.

    Technical Note

    Well characterized Thiophene & 2-Methyl thiophene are usedin a low sulfur Isooctane/Toluene matrix for this calibration set.

    New Requested Additions for use on XRF Energy

    Dispersive or Wavelength Instruments

    Cat. No. Sulfur Conc. Sulfur Wt. % UnitD-2622-LL-BL-4 Blank 0.0 4 oz.D-2622-LL-5X-4 5 g/g 0.0005 4 oz.D-2622-LL-10X-4 10 g/g 0.0010 4 oz.D-2622-LL-30X-4 30 g/g 0.0030 4 oz.D-2622-LL-50X-4 50 g/g 0.0050 4 oz.D-2622-LL-75X-4 75 g/g 0.0075 4 oz.D-2622-LL-100X-4 100 g/g 0.010 4 oz.D-2622-LL-300X-4 300 g/g 0.030 4 oz.D-2622-LL-500X-4 500 g/g 0.050 4 oz.D-2622-LL-1000X-4 1000 g/g 0.100 4 oz.

    D-2622-LL-CAL-SET $ 450 / 10 x 4 oz.

    In Isooctane : Toluene (3:1)Set contains the above 10 individual bottles

    Standards can be mixed for quantity discounts

    1 to 4 units $ 60 each per Sulfur Standard5 to 10 units $ 55 each per Sulfur Standardmore than 10 units $ 50 each per Sulfur Standard

    Cat. No. Sulfur Conc. Sulfur Wt. %D-3120-92-BL Blank D-3120-92-1X 1 g/g 0.0001D-3120-92-3X 3 g/g 0.0003D-3120-92-10X 10 g/g 0.0010D-3120-92-30X 30 g/g 0.0030D-3120-92-50X 50 g/g 0.0050D-3120-92-75X 75 g/g 0.0075D-3120-92-100X 100 g/g 0.010

    Well characterized di-n-butyl sulfide is used in a low sulfurIsooctane matrix for this calibration set.

    Technical Note

    Technical Note

    Sulfur StandardsASTM Methods

    A well characterized di-n-butyl sulfide starting matl is used with alow sulfur Isooctane matrix for RFG/gasoline sulfur standards.

    Technical Note

    Sulfur Calibration SetD-3120-92-CAL-SET $ 75 / set of 8 x 1 mLIn Isooctane

    Sulfur Calibration Standards in Isooctane forGasoline & Reformulated Gasoline Analysis Low Level Sulfur Calibration Standards for use on

    XRF Energy Dispersive or Wavelength InstrumentsOriginallydesigned for

    D-2622-98D-4294-98

    Originally

    designed forD-2622-98D-6334-98D-6445-99

    Originallydesigned forD-3120-96D-3246-96

    Originallydesigned forD-2622-98D-6334-98D-6445-99

    Member

    AccuStandard is an active member in ASTM and

    strives to keep abreast of ASTM method revisions.

    If our listed formulation does not meet the most

    recent method revision, please contact Technical

    Support, ext. 117 for an updated product.

  • 5/25/2018 Petroleum Standards

    17/116

    ASTM Methods Sulfur Standards

    ASTM D-2789 Hydrocarbon Types in Low Olefinic Gas by MS

    Fax 203-786-5287 Toll Free 800-442-5290 / 203-786-5290 Website www.accustandard.com

    ASTM-SSTD-A/B-SET $ 100 / 10 x 2 mLThe set contains the following 10 standards in isooctane

    (Vol. %)cis-1,2-Dimethylcyclohexane 15.5Benzene 7.7Toluene 10p-Xylene 16.5

    (Vol. %)2-Methylpentane 7.22,4-Dimethy lpentane 9.4n-Octane 16.6Methylcyclopentane 7.1Methylcyclohexane 10

    AccuStandard's Technical

    Service Dept. can provideReady-to-Inject working levcalibration standards to meeunique laboratory applicationCall or fax us your standardrequirements.

    Technical NoteSulfur in Residual Oil Standards

    Individual Sulfur 1 -10 units 10 +unitsStandards 4 oz Bottle $ 75 ea $ 65 ea

    Individual Sulfur 1 -10 units 10 +unitsStandards 4 oz Bottle $ 75 ea $ 65 ea

    Sulfur StandardsASTM Methods

    Trace Quantities of Sulfur in LiquidAromatic Hydrocarbons by OxidativeMicrocoulometryASTM-P-0020-PAK $ 75 / 5 x 1 mL1000 g/mL in Xylenes

    Sulfur (as Dibenzothiophene)

    Total Sulfur in Aromatic Compoundsby Hydrogenolysis & RateometricColorimetryASTM-P-0010-PAK $ 75 / 5 x 1 mL1000 g/mL in Toluene

    Sulfur (as Thiophene)

    Composition Test MixD-2789-CTM $ 40 / 1 x 1 mL

    D-2789-CTM-PAK SAVE 20% $ 160 / 5 x 1 mL9 comps.

    ASTM Methods Sulfur Calibration Standards

    ASTM

    Sulfur in Crude Oil Standards

    Both the actual volume %ratio and the final weightfractions for each analyte wbe listed on the certificate.

    Technical Note

    Concentration Sulfur in Crude Oil

    g/g Wt. % Cat. No.1,000 0.10 SCO-10X-42,500 0.25 SCO-25X-45,000 0.50 SCO-50X-4

    10,000 1.00 SCO-100X-420,000 2.00 SCO-200X-430,000 3.00 SCO-300X-440,000 4.00 SCO-400X-450,000 5.00 SCO-500X-4

    Set of above SCO-CAL-SET-4Cat. No.s 8 x 4 oz. $ 500

    Concentration Sulfur in Crude Oil

    g/g Wt. % Cat. No.3,500 0.35 SRO-35X-47,000 0.70 SRO-70X-4

    10,000 1.00 SRO-100X-415,000 1.50 SRO-150X-420,000 2.00 SRO-200X-430,000 3.00 SRO-300X-440,000 4.00 SRO-400X-4

    Set of above SRO-CAL-SET-4Cat. No.s 7 x 4 oz. $ 450

    Cat. No. Description Unit

    ASTM-SSTDA-BL Sulfur Blank 2 mL

    ASTM-SSTDA-01 Sulfur @ 0.5 g/g in Isooctane 2 mLASTM-SSTDA-02 Sulfur @ 1.0 g/g in Isooctane 2 mLASTM-SSTDA-03 Sulfur @ 2.5 g/g in Isooctane 2 mLASTM-SSTDA-04 Sulfur @ 5.0 g/g in Isooctane 2 mL

    ASTM-SSTDB-BL Sulfur Blank 2 mLASTM-SSTDB-04 Sulfur @ 5.0 g/g in Isooctane 2 mLASTM-SSTDB-05 Sulfur @ 10.0 g/g in Isooctane 2 mLASTM-SSTDB-06 Sulfur @ 25.0 g/g in Isooctane 2 mLASTM-SSTDB-07 Sulfur @ 50.0 g/g in Isooctane 2 mL

    Originallydesigned for

    D-2789-95

    Sulfur Standards for ASTM D-2622, D-3120, D-3246, D-4294, D-5453, D-6334, D-6445 &Proposed ASTM Sulfur Methods

  • 5/25/2018 Petroleum Standards

    18/116

    12 Quality System is Certified to comply with the International ISO 9001 Quality Standard

    PIANO

    PIANO, PONA, PNA Analysis

    PIONA

    PIANO, PONA, PNA

    High Aromatic PIAN BlendASTM-P-0037 $ 120 / 100 L

    110 comps.High Aromatic blend contains the PIAN componentsblended to resemble a reformate. The actual certificatewill have the exact weight % for each analyte accurateto four decimal places. Analyte list is drawn fromCat. No.s: ASTM-P-0031, ASTM-P-0032,ASTM-P-0033, ASTM-P-0034

    Low Aromatic PIAN BlendASTM-P-0036 $ 120 / 100 L

    110 comps.Low Aromatic blend contains the PIAN componentsblended to resemble a light naphtha. The actual certificatewill have the exact weight % for each analyte accurate tofour decimal places. Analyte list is drawn fromCat. No.s: ASTM-P-0031, ASTM-P-0032,ASTM-P-0033, ASTM-P-0034

    AccuStandard has introduced the PIANO line of quantitative and qualitative Petrochemical Standards for class type analysis of petrochemica

    samples or product streams. PIANO analysis involves the determination of the percentage of the following five fractions Paraffins, Isoparaf

    Aromatics, Naphthenes, and Olefins.

    PONA analysis involves analyzing the naphtha sample for Paraffins, Olefins, Naphthenes, and Aromatics. If the Isoparaffins and Olefins are

    present, the analysis is just for PNA.

    The PIANO line of standards is used to determine quantitative and qualitative retention times and indices as well as to monitor response fact

    within the hydrocarbon blend. These complex mixes are prepared from materials of the highest available purity, accurate to four decimal plaand include a detailed data sheet on the formulation composition. The typical range for the analytes in each formulation has been provided f

    each catalog item. The exact composition on a weight % basis for each analyte has been provided on the certificate, and a disk deliverable

    spreadsheet is available on request.

    Mini Inert Valves SealThe PIANO standards are supplied in convenient to use crimp top vials with Viton septa that resist

    mineral oil, aliphatic, aromatics hydrocarbons, and higher temperatures. Mini inert valve seals are

    available for an additional $ 25 vial. To order, add -MIV to any of the PIANO catalog numbers on

    this page.

    For individual PIANO descriptions see next page

    Standards of Interest

    PIANO

    PONA

    PNA

    AccuStandard, Your Standards and Technical Information Source!

    Total PetroleumHydrocarbon PatternRecognition Standards

    BOOK-TPH $ 35

    Analytical Standards andReference Material for all209 PCB Congeners

    S-3571 $ 25

    PIANO MixtureASTM-P-0030 $ 250 / 100 L

    135 comps.The PIANO formulation contains the n-Paraffins,Isoparaffins,Aromatics, Naphthenes, and Olefins from thefive Cat. No.s: ASTM-P-0031, ASTM-P-0032,

    ASTM-P-0033, ASTM-P-0034, ASTM-P-0035

    Approximate weight percentages for the total: n-Paraffins18.5%, Isoparaffins 17.9%, Aromatics 23.6%, Naphthenes20.9%, Olefins 19.0%.The actual certificate will list the weight % for all analytesin the formulation.

  • 5/25/2018 Petroleum Standards

    19/116

    PIANO, PONA, PNA Analysis

    Fax 203-786-5287 Toll Free 800-442-5290 / 203-786-5290 Website www.accustandard.com

    PIAN

    AccuStandard may add and/or subtractPIANO Analytes and vary the weight %for each Analyte. The certificate willreflect the exact Analyte composition.

    Production Note

    PIANO, PONA, PNA

    Typ. Wt. %3-Methyl-1-butene 1.93961-Pentene 4.13552-Methyl-1-butene 1.44402-Methyl-1,3-butadiene 2.3889trans-2-Pentene 1.8034cis-2-Pentene 1.9792

    4-Methylpentene-1 3.43721-Hexene 7.0484trans-2-Hexene 1.73022-Methylpentene-2 3.3901cis-2-Hexene 3.87651-Heptene 7.6134trans-3-Heptene 3.3469cis-3-Heptene 5.8657trans-2-Heptene 3.7217cis-2-Heptene 5.76791-Octene 7.6901trans-2-Octene 1.9432cis-2-Octene 3.95021-Nonene 7.6425trans-3-Nonene 1.9972cis-3-Nonene 4.0042trans-2-Nonene 1.9848cis-2-Nonene 2.7952

    1-Decene 8.2053

    Typ. Wt. %Cyclopentane 4.9143Methylcyclopentane 3.2829Cyclohexane 5.32681,1-Dimethylcyclopentane 3.4612cis-1,3-Dimethylcyclopentane 0.5963trans-1,2-Dimethylcyclopentane 1.4715trans-1,3-Dimethylcyclopentane 2.7531

    Methylcyclohexane 5.6091Ethylcyclopentane 3.5534ctc-1,2,3-Trimethylcyclopentane 1.5859cct-1,2,4-Trimethylcyclopentane 3.7208ctc-1,2,4-Trimethylcyclopentane 1.6467trans-1,4-Dimethylcyclohexane 3.64991-Ethyl-1-methylcyclopentane 1.0554trans-1,2-Dimethylcyclohexane 1.6537ccc-1,2,3-Trimethylcyclopentane 0.7971Isopropylcyclopentane 3.5042cis-1,2-Dimethylcyclohexane 3.7159n-Propylcyclopentane 3.6438ccc-1,3,5-Trimethylcyclohexane 3.52631,1,4-Trimethylcyclohexane 3.6791ctt-1,2,4-Trimethylcyclohexane 3.6107ctc-1,2,4-Trimethylcyclohexane 3.50691,1,2-Trimethylcyclohexane 3.3354Isobutylcyclopentane 3.7123Isopropylcyclohexane 5.7233n-Butylcyclopentane 3.6944Isobutylcyclohexane 5.6729t-1-Methyl-2-propylcyclohexane 3.8434t-1-Methyl-2-(4MP)cyclopentane 3.7534

    PIANO Olefins MixASTM-P-0035 $ 120 / 100 L25 Olefins listed below at varying Wt. %typically in the range from 1.2 to 9.0 Wt. %.The actual certificate will have the exact Wt. %for each analyte.

    PIANO Naphthenes MixASTM-P-0034 $ 120 / 100 L30 Napthenes listed below at varying Wt. %typically in the range from 0.5 to 8.0 Wt. %. Theactual certificate will have the exact Wt. % foreach analyte.

    Typ. Wt. %n-Pentane 9.4375n-Hexane 9.5661n-Heptanea 9.8048n-Octane 9.5518n-Nonane 9.0482n-Decane 9.2517n-Undecane 9.3172n-Dodecane 9.1855n-Tridecane 8.9332

    n-Tetradecane 8.7989n-Pentadecane 7.1057

    Typ. Wt. %Benzene 7.1437Toluene 4.5738EthylBenzene 6.7670m-Xylene 2.2259p-Xylene 4.4815o-Xylene 2.2519

    Isopropylbenzene 2.2248n-Propylbenzene 4.49791-Methyl-3-ethylbenzene 2.22431-Methyl-4-ethylbenzene 2.22061,3,5-Trimethylbenzene 1.10761-Methyl-2-ethylbenzene 2.26111,2,4-Trimethylbenzene 2.2535tert-Butylbenzene 4.5310Isobutylbenzene 4.4216sec-Butylbenzene 2.23681-Methyl-3-isopropylbenzene 1.10661-Methyl-4-isopropylbenzene 1.06681-Methyl-2-isopropylbenzene 1.12411-Methyl-3-n-propylbenzene 2.11351-Methyl-4-n-propylbenzene 2.2336n-Butylbenzene 2.20871,2-Diethylbenzene 1.09471-Methyl-2-n-propylbenzene 2.2641

    1,4-Dimethyl-2-ethylbenzene 2.28031,3-Dimethyl-5-ethylbenzene 2.28581,2-Dimethyl-4-ethylbenzene 2.25581,3-Dimethyl-2-ethylbenzene 1.14161,2-Dimethyl-3-ethylbenzene 2.18641,2,4,5-Tetramethylbenzene 0.23602-Methylbutylbenzene 1.1453trans-1-Butyl-2-methylbenzene 0.7641n-Pentylbenzene 4.4828t-1-Butyl,3,5-dimethylbenzene 2.1641t-1-butyl-ethylbenzene 2.23221,3,5-Triethylbenzene 4.56711,2,4-Triethylbenzene 1.1087n-Hexylbenzene 4.5029

    Typ. Wt. %2,3-Dimethylheptane 1.48703,4-Dimethylheptane 3.74502-Methyloctane 3.75763-Methyloctane 5.60203,3-Diethylpentane 1.57552,2-Dimethyloctane 3.41353,3-Dimethyloctane 3.25822,3-Dimethyloctane 3.88423-Ethyloctane 3.74822-Methylnonane 3.7144

    3-Methylnonane 5.7687

    Typ. Wt. %2,2-Dimethylhexane 1.30612,5-Dimethyl hexane 3.69752,2,3-Trimethylpentane 1.73712,4-Dimethylhexane 1.62522,3-Dimethylhexane 1.62122-Methylheptane 4.40734-Methylheptane 3.20153-Methylheptane 5.51863-Ethylhexane 0.69993,3-Dimethylheptane 1.7011

    2,5-Dimethylheptane 5.67313,5-Dimethylheptane 0.7565

    Typ. Wt. %Isopentane 2.19282,3-Dimethylbutane 0.44662-Methylpentane 3.28153-Methylpentane 5.38652,2-Dimethylpentane 1.77472,4-Dimethylpentane 3.69932,2,3-Trimethylbutane 3.92913,3-Dimethylpentane 1.18482-Methylhexane 2.23842,3-Dimethylpentane 1.7883

    3-Methylhexane 1.67083-Ethylpentane 0.5080

    PIANO Aromatics MixASTM-P-0033 $ 120 / 100 L38 Aromatics listed below at varying Wt. %typically in the range from 0.2 to 7.0 Wt. %.The actual certificate will have the exactWt. % for each analyte.

    PIANO n-Paraffins MixASTM-P-0031 $ 80 / 100 L11 paraffins listed below at varying Wt. %typically in the range from 7.0 to 11.0 Wt. %.The actual certificate will have the exact Wt.% for each analyte.

    PIANO Mix SetASTM-PIANO-SET $ 700 / 6 x 100 LSet includes the following Cat. No.:ASTM-P-0030, ASTM-P-0031, ASTM-P-0032,ASTM-P-0033, ASTM-P-0034, ASTM-P-0035

    Special PackagingMini inert valve seals are available for an additional $ 25 / vial.To order, add -MIV to any of the PIANO cat.# on this page.

    PIANO Isoparaffins MixASTM-P-0032 $ 120 / 100 L35 Isoparaffins listed below at varying Wt. % typically in the range from 0.5 to 6.0 Wt. %. The actualcertificate will have the exact Wt. % for each analyte.

    PIANO MixtureASTM-P-0030 $ 250 / 100 L (135 comps.)The PIANO formulation contains the n-Paraffins, Isoparaffins,Aromatics, Naphthenes, and Olefins from

    the Five Cat. No.s: ASTM-P-0031, ASTM-P-0032, ASTM-P-0033, ASTM-P-0034, ASTM-P-0035

    Approximate weight %s for the total: n-Paraffins 18.5%, Isoparaffins 17.9%, Aromatics 23.6%,Naphthenes 20.9%, Olefins 19.0%. The certificate lists the weight % for all analytes in the formulation.

  • 5/25/2018 Petroleum Standards

    20/116

    14 Quality System is Certified to comply with the International ISO 9001 Quality Standard

    Member

    ASTM

    ASTM D-2887 Boiling Range Distribution of Petroleum Fractions by GC

    Detailed Hydrocarbon Analysis

    AccuStandard offers a hydrocarbon window defining standard with the C8 to C40 odd and

    even Alkanes. As an added benefit, AccuStandard included pristane and phytane in theformulation. Use of this one standard measuring the C17/ pristane and C18/ phytane ratio

    can be used to estimate degradation of fuel oil.

    If you prefer, AccuStandard has also developed a fuel oil degradation mixture containingjust the four required analytes to determine the C17/pristane and C8/ phytane ratio

    Catalog Numbers DRH-005S-10X.

    Technical Note

    This sample is a petroleum fractionhaving a boiling range from 250F to850F, evaluated in round robinstudies by the ASTM D-02committee. Use of this sample andthe supplied ASTM boiling rangeconsensus values helps to evaluatesystem performance

    Technical NoteTriacontanen-HentriacontaneDotriacontaneTritriacontaneTetratriacontanePentatriacontaneHexatriacontaneHeptatriacontaneOctatriacontaneNonatriacontane

    Tetracontane

    Wt. %n-Octadecane 5n-Eicosane 2n-Tetracosane 2n-Octacosane 1n-Dotriacontane 1n-Hexatriacontane 1n-Tetracontane 1n-Tetratetracontane 1

    Wt. %n-Hexane 6n-Heptane 6n-Octane 8n-Nonane 8n-Decane 12n-Undecane 12n-Dodecane 12n-Tetradecane 12n-Hexadecane 10

    Column Test MixtureASTM-D2887 $ 10 / 1 x 1 mL1% v/v in n-Octane 2 comps.

    n-Hexadecane n-Octadecane

    HeptadecaneOctadecanePhytane (2,6,10,14-Tetramethylhexadecane)Pristane (2,6,10,14-Tetramethylpentadecane)

    NonadecanePhytaneEicosaneHeneicosaneDocosaneTricosaneTetracosanePentacosaneHexacosaneHeptacosane

    OctacosaneNonacosane

    OctaneNonaneDecaneUndecaneDodecaneTridecaneTetradecanePentadecaneHexadecaneHeptadecane

    OctadecanePristane

    Detailed Hydrocarbon Analysis

    Fuel Oil Degradation/RetentionTime Mix for Quantification ofC17/Pristane & C18/Phytane ratiosDRH-005S-10X $ 20 / 1 x 1 mL

    2.0 mg/mL each in CH2Cl2 : CS2 (1:1) 4 comps.

    Calibration MixDRH-002N $ 10 / 100 mgDRH-002N-10X $ 40 / 1 gm

    17 comps.

    Complete Hydrocarbon Analysis

    Hydrocarbon WindowDefining Standard*DRH-008S-R2 $ 65 / 1 x 1 mLDRH-008S-R2-PAK SAVE 20% $ 260 / 5 x 1 mL500 g/mL each in Chloroform 35 comps.

    Method 2887

    DHA

    Proposed ASTM Method for Detailed Hydrocarbon Analysis (DHA)Determination of Individual Components and Groups of Components in Spark Ignition Engine fuels byHigh Efficiency Open Tubular Column Gas Chromatography (Detailed Hydrocarbon Analysis)

    Detailed Hydrocarbon Analysis (includes oxygenates)

    ASTM-P-0038 $ 120 / 100 L30 Analytes listed below at varying targeted weight %. The actual certificate will has the exact Wt. % for each analyte.

    p-XyleneEthylbenzeneOctane2,3-DimethylheptaneNonane5-Methylnonane1-Ethyl-2-methylbenzene

    BenzeneCyclohexane3-Ethylpentanet-1,2-DimethylcyclopentaneHeptane2,2,3-Trimethylpentane2,3,3-TrimethylpentaneToluene

    EthanolPentane2-Methyl-2-propanol2-Methylbutene2,3-DimethylbutaneMethyl-t-butyl etherHexaneMethylcyclopentene

    DecaneUndecane1,2,3,5-TetramethylbenzeneNaphthaleneDodecane1-MethylnaphthaleneTridecane

    DHA - PONA-VI (PONA 6) is aqualitative mixture of variousgasoline and refinery materialsprepared to provide nearly everycomponent that may be encounte

    in feedstock and finished gasolineSome oxygenates have been addto allow this blend to be used forDHA method setup. This blendcontains approximately 450components (peaks).

    ASTM-P-0139 $ 120 / 100 L

    Calibration Solution *

    DRH-002S-R1 $ 50 / 1 x 1 mLDRH-002S-R1-PAK SAVE 20% $ 200 / 5 x 1 mLAt stated conc. in Chloroform 17 comps.

    Calibration Solution *

    DRH-002S-R2 $ 50 / 1 x 1 gmDRH-002S-R2-PAK SAVE 20% $ 200 / 5 x 1 gm1 % Wt./Wt. each in Chloroform 20 comps.

    NEW

    g/mLn-Hexane 600n-Heptane 600n-Octane 800n-Nonane 800n-Decane 1200n-Undecane 1200n-Dodecane 1200n-Tetradecane 1200n-Hexadecane 1000

    g/mLn-Octadecane 500n-Eicosane 200n-Tetracosane 200n-Octacosane 100n-Dotriacontane 100n-Hexatriacontane 100n-Tetracontane 100n-Tetratetracontane 100

    n-Tetratetracontanen-Tetracontanen-Hexatriacontanen-Dotriacontanen-Octacosanen-Tetracosanen-Eicosane

    n-Octadecanen-Hexadecanen-Tetradecanen-Dodecanen-Undecanen-Decane

    NEW

    n-Nonanen-Octanen-Heptanen-Hexanen-Pentanen-Pentadecanen-Heptadecane

    * Can be shipped by Air and Sea

    ASTM D-2887 Reference GasOil Sample Lot #2D-2887-REFOIL $ 35 / 1 x 1

    Originally designed for D-2887-99

  • 5/25/2018 Petroleum Standards

    21/116

    SIM DIS Standards Simulated Distillation

    Fax 203-786-5287 Toll Free 800-442-5290 / 203-786-5290 Website www.accustandard.com

    Memb

    Meth

    See ASTM Methods D-3710D-5307, D-5442, D-6352 foadditional calibrationstandards for hydrocarbonanalysis.

    Standards of Interest

    AccuStandard designed thefollowing formulations for aProposed ASTM Method undevelopment for Motor OilVolatility analysis & SIM DISapplications.

    Technical Note

    Polywax 1000

    ASTM-P-0138N-2G $ 20 / 2 grams

    Polywax 1000

    Polywax 850

    ASTM-P-0137N-2G $ 20 / 2 grams

    Polywax 850

    Simulated Distillation (SIM DIS) and Proposed Motor Oil Volatility MethodAccuStandard has developed an extensive line of SIM DIS standards for normal and high temperature analytical requirements when generati

    boiling point versus retention time calibration curves. Since normal paraffins above Alkane C60 are not readily available, Polywax 500, Poly

    655, Polywax 850 and Polywax 1000 standards have been incorporated to perform SIM DIS analysis of heavy petroleum fractions with boili

    points up to 1350 F. If you require additional analytes added to the formulations for extended SIM DIS work, use our custom quotation req

    form located in the back of the catalog.

    Wt. %n-Tetradecane 0.0333n-Pentadecane 0.0333n-Hexadecane 0.0333n-Heptadecane 0.0333n-Octadecane 0.0333n-Eicosane 0.0333Polywax 500 0.5

    Wt. %n-Pentane 0.0333n-Hexane 0.0333n-Heptane 0.0333n-Octane 0.0333n-Nonane 0.0333n-Decane 0.0333n-Undecane 0.0333n-Dodecane 0.0666

    Polywax 655

    ASTM-P-0053N-2G $ 20 / 2 grams

    Polywax 655

    Polywax 500

    ASTM-P-0051N-2G $ 20 / 2 grams

    Polywax 500

    Working Level SIM DIS Paraffin Solutionwith Polywax 500ASTM-P-0052 $ 40 / 1 x 1 mLASTM-P-0052-PAK SAVE 20% $ 160 / 5 x 1 mLAt stated conc. in Carbon disulfide 15 comps.

    Petrochemical Standards

    Wt. %n-Dodecane 13.33n-Tetradecane 6.66n-Pentadecane 6.66n-Hexadecane 6.66n-Heptadecane 6.66n-Octadecane 6.66n-Eicosane 6.66

    Wt. %n-Pentane 6.66n-Hexane 6.66n-Heptane 6.66n-Octane 6.66n-Nonane 6.66n-Decane 6.66n-Undecane 6.66

    Stock SIM DIS Paraffin SolutionASTM-P-0050 $ 85 / 1 x 5 mL

    14 comps.

    For our complete line ofOrganic Standards,request a copy of ourOrganic Catalog

    For our complete line ofInorganic Standards,request a copy of ourInorganics Catalog

  • 5/25/2018 Petroleum Standards

    22/116

    ASTM D-3230 Salts in Crude Oil

    ASTM D-3237 Lead in Gasoline by AA Spectroscopy

    ASTM D-3231 Phosphorus in Gasoline

    ASTM D-3120 & D-3246 Trace Quantities of Sulfur in Light Liquid Petroleum Hydrocarbons by Oxidative Microcoulom

    16 Quality System is Certified to comply with the International ISO 9001 Quality Standard

    Method

    ,ASTM Standards

    Sodium chloride 70 g/mLCalcium chloride 10 g/mLMagnesium chloride 20 g/mL

    See page 1 for AccuStandacomprehensive line of Certif

    Sulfur calibration standardsAccuPetroCheck, andAccuPetroTest quality controproducts.

    Standards of Interests

    Well characterized di-n-butyl sulfide is usedin a low sulfur Isooctane matrix for thiscalibration set.

    Technical NoteCat. No. Sulfur Conc. Sulfur Wt.%

    D-3120-BL Blank BlankD-3120-92-1X 1 g/g 0.0001D-3120-92-3X 3 g/g 0.0003D-3120-92-10X 10 g/g 0.0010D-3120-92-30X 30 g/g 0.0030D-3120-92-50X 50 g/g 0.0050D-3120-92-75X 75 g/g 0.0075D-3120-92-100X 100 g/g 0.010

    Method 3120

    3230

    3231

    3237

    D-3231

    Meets

    EPAGuidelines

    forRFG

    Analysis

    D-3237

    Meets

    EPAGuidelines

    forRFG

    Analysis

    Element Quantity Cat. No. PriceMatrix Conc.

    Phosphorus 100 mL ICP-41W-1 $ 34H2O 1000 g/mL

    Phosphorus 500 mL ICP-41W-5 $ 67H2O 1000 g/mL

    Mixed Salt SolutionD-3230-89-1 $ 75 / 100 mLD-3230-89-5 $ 150 / 500 mLAt stated conc. in Alcohol Solution (1-butanol : MeOH) (ratio 63:37) tr. H2O 3 comps.

    Sulfur Calibration SetD-3120-92-CAL-SET $ 75 / set of 8 x 1 mLIn Isooctane

    Lead Standard Calibration CurveD-3237-CAL-SET $ 210 / 4 x 100 mLSet includes the following Catalog Numbers:

    Cat. No. Description Price / UnitD-3237-01 Blank 1% Aliquot 336/MIBK $ 20 /100 mLD-3237-02 0.02 g Pb / gal ( 5 .3 mg Pb/ L) in 1% Aliquat 336 / MIBK $ 80 /100 mLD-3237-03 0.05 g Pb / gal ( 13.2 mg Pb/ L) in 1% Aliquat 336 / MIBK $ 80 / 100 mLD-3237-04 0.10 g Pb / gal ( 26.4 mg Pb/ L) in 1% Aliquat 336 / MIBK $ 80 / 100 mL

    Working Level Standards &

    Continuing Calibration Check (CCC)

    Ready-to-Inject Petrochemical Standards and Calibration Curves

    Reduce Costs

    Increase Time Spent for Sample Analysis

    Are Validated Against Independent Lots

    Include Internal Standards or Surrogates

    Follow ASTM Method Guidelines

    Allow Direct Transfer to Autosampler Vials

    Ready-to-Inject

    Member

    ASTM

    Originally designed forD-3120-96D-3246-96

    Originally designed forD-3230-99

    Originally designed for D-3231-99

    Originally designed forD-3237-97

  • 5/25/2018 Petroleum Standards

    23/116

    ASTM D-3605 Trace Metals in Gas Turbine Fuels by AA &(Reapproved 1995) Flame Emission Spectroscopy

    ASTM D-3524 (Reapproved 1999) Diesel Fuel Diluent in Used Diesel Engine Oils by GC

    Fax 203-786-5287 Toll Free 800-442-5290 / 203-786-5290 Website www.accustandard.com

    Technical Note

    ASTM Standards

    Column Resolution MixD-3524-CR $ 10 / 1 x 1 mLD-3524-CR-PAK SAVE 20% $ 40 / 5 x 1 mLAt stated conc. in n-Heptane 2 comps.

    Wt. / Wt. %n-Hexadecane 1.0n-Octadecane 1.0

    Internal Standard SolutionD-3524-IS-10ML $ 25 / 1 x 10 mL

    D-3524-IS-10ML-PAK SAVE 20% $ 100 / 5 x 10 mLAt stated conc. in n-Heptane 2 comps.

    Wt. / Wt. %n-Decane 1.0n-Octadecane 0.2

    Meth

    ASTM D-3246 Sulfur in Petroleum Gas by Oxidative Microcoulometry

    ASTM D-3340 Lithium & Na in Lubricating Greases by Flame Photometer

    * For your convenience these elements arealso available in HNO3. To order HNO3change the H to N at the end of the Cat. No.

    Test to

    Low ppb

    Sulfur

    Mid Level Daily QC SolutionD-3524-QC-10ML $ 30 / 1 x 10 mL

    2 comps.Wt. / Wt. %

    # 2 Diesel 5.030 W Motor oil 95

    See pages 6 - 11 for AccuStandards comprehensive line of certified sulfur calibration standards

    AccuStandard AccuTrace brand AA standards are produced under our rigorous ISO 9001 quality system toexacting specifications. Each standard is prepared from high purity starting materials; deionized water andhigh purity acids. Every standard is instrumentally assayed to verify 1000 ppm concentration of specifiedelement; Actual Lot Analysis is provided on the label and a Certificate of Analysis is included for ease ofrecord keeping and availability at audits.

    D-3524 Calibration CurveD-3524-CAL-SET-5ML $ 150 / set of 6 x 5 mLD-3524-CAL-SET-10ML $ 250 / set of 6 x 10 mL

    Analyte Standard 1 Standard 2 Standard 3 Standard 4 Standard 5 Standard 6Target Wt. % Target Wt. % Target Wt. % Target Wt. % Target Wt. % Target Wt. %

    # 2 Diesel 10 7.5 5 2.5 1 030 W Motor oil 90 92.5 95 97.5 99 100

    Element Unit Cat. No. Price

    Matrix 1,000 g/mL

    Lithium * 100 mL AA30H-1 $ 12HCl 500 mL AA30H-5 30

    Sodium * 100 mL AA54H-1 13HCl 500 mL AA54H-5 33

    Ca (Calcium) (250 g/mL)V (Vanadium) (250 g/mL)

    Na (Sodium) (250 g/mL)Pb (Lead) (250 g/mL)

    See Table of Contents for thWear Metals Group pages

    Standards of InterestsD-3605-91 Trace Metals StandardD-3605-91-1 $ 165 / 1 x 100 mLAt stated conc. in 1,2,3,4-Tetrahydronaphthalene 4 comps.

    Memb

    See Pages 6-11

    Originally designed forD-3340-98

    Originally designed forD-3524-90

    Originally designed forD-3605-91

  • 5/25/2018 Petroleum Standards

    24/116

    18 Quality System is Certified to comply with the International ISO 9001 Quality Standard

    ASTM

    D-3606

    Meets

    EPAGuidelines

    forRFG

    Analysis

    ASTM Standards

    ASTM D-3606 Benzene & Toluene in Finished Motor & Aviation Gasoline by GC

    Aromatics Quantitative Calibration Standard (with Internal Standard: MEK)D-3606/IS-SET $ 115 / set of 7 x 1 mLD-3606/IS-SET-2ML $ 190 / set of 7 x 2 mLD-3606/IS-SET-2ML-PAK $ 760 / 5 x (7 x 2) mL

    Analyte Std. 1 Std. 2 Std. 3 Std. 4 Std. 5 Std. 6 Std. 7Calibr. range Target Vol. % Vol. % Vol. % Vol. % Vol. % Vol. % Vol. %

    Benzene 0.06 - 5.0 4.8 2.4 1.2 0.6432 0.3168 0.1152 0.0576Toluene 0.5 - 20 19.2 14.4 9.6 4.8000 2.4000 0.9600 0.4800Isooctane 72.0 79.2 85.2 90.5568 93.2832 94.9248 95.4624Methyl ethyl ketone (Internal Std.) 4.0 4.0 4.0 4.0 4.0 4.0 4.0

    Due to changes in the poss

    use of other oxygenates likeethanol added to gasoline,AccuStandard formulated anew calibration curve usingsec-butanol as an InternalStandard. The use of this nISTD minimizes coelutioncaused by the oxygenate(sand pre column - standardcolumn configuration in the system.

    Technical Note

    Daily Quality Control Standard(without Internal Standard)D-3606-QC-25ML $ 125 / 1 x 25 mLD-3606-QC-25ML-PAK $ 600 / 5 x 25 mLEach at stated quantities 3 comps.

    Compound Target Vol. %Benzene 0.67Toluene 5.00Isooctane 94.33

    100

    Gasoline Refinery Quality Control Standards

    Daily Quality Control Standard(with Internal Standard: sec Butanol)D-3606-QC-IS2-25ML $ 125 / 1 x 25 mLD-3606-QC-IS2-25ML-PAK $ 600 / 5 x 25 mLEach at stated quantities 4 comps.

    Compound Target Vol. %Benzene 0.6432Toluene 4.8000Isooctane 90.5568sec-Butanol (ISTD) 4.0

    100

    Aromatics Quantitative Calibration Standard (w/ Internal Standard: sec Butanol)D-3606/IS2-SET $ 115 / set of 7 x 1 mL

    D-3606/IS2-SET-PAK $ 500 / 5 x (7 x 1) mL

    Analyte Std. 1 Std. 2 Std. 3 Std. 4 Std. 5 Std. 6 Std. 7Calibr. range Target Vol. % Vol. % Vol. % Vol. % Vol. % Vol. % Vol. %

    Benzene 0.06 - 5.0 4.8 2.4 1.2 0.6432 0.3168 0.1152 0.0576Toluene 0.5 - 20 19.2 14.4 9.6 4.8000 2.4000 0.9600 0.4800Isooctane 72.0 79.2 85.2 90.5568 93.2832 94.9248 95.4624sec Butanol (Internal Standard) 4.0 4.0 4.0 4.0 4.0 4.0 4.0

    Daily Quality Control Standard(with Internal Standard: MEK)D-3606-QC/IS-10ML $ 75 / 1 x 10 mLD-3606-QC/IS-10ML-PAK $ 300 / 5 x 10 mLEach at stated quantities 4 comps.

    Compound Target Vol. %Benzene 0.6432Toluene 4.8000Isooctane 90.5568Methyl ethyl ketone (ISTD) 4.0

    100

    Daily Quality Control Standard(without Internal Standard)D-3606-QC-25ML $ 125 / 1 x 25 mLD-3606-QC-25ML-PAK $ 600 / 5 x 25 mLEach at stated quantities 3 comps.

    Compound Target Vol. %Benzene 0.67Toluene 5.00Isooctane 94.33

    100

    Gasoline Refinery Quality Control Standards

    Aromatics Quantitative Calibration Standard (without Internal Standards)D-3606-SET-25ML $ 800 / set of 7 x 25 mL

    Analyte Std. 1 Std. 2 Std. 3 Std. 4 Std. 5 Std. 6 Std. 7Calibr. range Target Vol. % Vol. % Vol. % Vol. % Vol. % Vol. % Vol. %

    Benzene 0.06 - 5.0 5.00 2.50 1.25 0.67 0.33 0.12 0.06

    Toluene 0.5 - 20 20.00 15.00 10.00 5.00 2.50 1.00 0.50Isooctane 75.00 82.50 88.75 94.33 97.17 98.88 99.44

    ASTM D-3610 Total Cobalt in Alumina-Base Cobalt-Molybdenum Catalyst by Potentiometric Titration

    Cobalt Oxide StandardD-3610-93-1 $ 50 / 1 x 100 mL

    Cobalt oxide @ 1500 g/mL in Water

    Method 3606

    3610

    ,

    Member

    Originally designed forD-3606-99

    Originally designed forD-3610-88 (Re-Approved 1993)

  • 5/25/2018 Petroleum Standards

    25/116

    Fax 203-786-5287 Toll Free 800-442-5290 / 203-786-5290 Website www.accustandard.com

    Test to

    Low ppb

    SulfurSee Pages 6-11

    Cross Reference TableASTM IP ISO DIN JIS AFNOR sorted by

    ASTM Method see beginning of Catalog

    There is an easier way to get Chemical Reference Standarde-Standards

    from AccuStandard.com

    Over 30,000 Standards

    just a click away

    On-Line Ordering

    5 Ways to Searche-Standards is the Fastest, Most Comprehensive Search Engine

    available and contains over 30,000 products.

    Search by:

    Catalog Number

    Single or Multiple Components,

    Method (EPA, ASTM, etc.)

    Chemical Category (Organic, Inorganic, Petroleum, etc.)

    Other Companies Part Number

    Log on to www.accustandard.com and see how easy it is.

    Easy Ordering 24/7Find It Fast...simply search for a product, select it for purchase &

    click - it's that easy! Discounts may apply to online orders, see

    details on website.

    On-Line Custom ServicesAccuStandard specializes in synthesizing chemicals of high purity

    to be used as reference standards, and offers custom synthesis

    capability for milligram to kilogram batches. If you can't find the

    specific standard you need, we can prepare Custom Formulationsand Custom Packaging for both Organic and Inorganic needs.

    See our Website for more info.

  • 5/25/2018 Petroleum Standards

    26/116

    ASTM D-3831 Manganese in Gasoline by AA Spectroscopy

    ASTM D-3710 (Reapproved 1999) Boiling Range Distribution of Gasoline & Gasoline Fractions by GC

    20 Quality System is Certified to comply with the International ISO 9001 Quality Standard

    Method 3710

    3798

    , 3831

    See page 3 for AccuStandanew D-86 QA/QC Standards

    Standards of Interests

    ASTM Standards

    Technical Note

    Bulk Packaged p-Xylenewithout Internal StandardOther suggested internalstandards can be used inconjunction with the bulkpackaged D-3789 1 x 10 mLampule to meet your compaapplication. If you prefer toeliminate making standards,contact AccuStandardsTechnical Department with yunique formulation for a cusquotation. The customquotation request form islocated in the back of this

    catalog.

    Manganese Stock SolutionD-3831 $ 65 / 1 x 100 mL

    Manganese @ 1.0 g Mn / gal (264.2 mg Mn / L) in Methyl isobutyl ketone

    n-Octane 5.8n-Pentadecane 2.3n-Pentane 8.1n-Propylbenzene 4.7n-Tetradecane 2.3Toluene 11.6n-Tridecane 2.3p-Xylene 14.0

    Vol./Vol. %n-Butylbenzene 3.5n-Decane 3.52,4-Dimethylpentane 5.8n-Dodecane 3.5n-Heptane 10.5n-Hexane 5.82-Methylbutane 10.52-Methylpentane 5.8

    Vol./Vol. %

    Approx.Wt./ Wt. %

    n-Octane 5.4n-Pentadecane 2.2n-Pentane 7.6n-Propane 1.5n-Propylbenzene 4.3n-Tetradecane 2.2Toluene 10.8n-Tridecane 2.2p-Xylene 13

    Approx.Wt./ Wt. %

    n-Butane 4.5n-Butylbenzene 3.2n-Decane 3.22,4-Dimethylpentane 5.4n-Dodecane 3.2n-Heptane 9.7n-Hexane 5.42-Methylbutane 9.72-Methylpentane 5.42-Methylpropane 1.5

    Quantitative Calibration StandardASTM-D3710 $ 25 / 1 x 1 mLASTM-D3710-PAK SAVE 36% $ 80 / 5 x 1 mL

    16 comps.

    Qualitative Calibration StandardD-3710-QUAL $ 30 / 1 x 1 mLD-3710-QUAL-PAK SAVE 20% $ 120 / 5 x 1 mL

    19 comps.

    ASTM D-3798 Analysis of p-Xylene by GC

    This SIM DIS (Simulated Distillation or GCD) Method is used to determine the boiling range distribution ofgasoline and gasoline components. ASTM Method D-3710 is used for petroleum products and fractionswith a final boiling point of 500F (260C) or lower. By having an insight into the composition of thegasoline blend, essential data for the calculation of vapor pressure and a prediction of the D-86 distillationcurve can be made.

    p-Xylene Impurity Standardwithout ISTDD-3798-10ML $ 65 / 1 x 10 mLD-3798-10ML-PAK SAVE 20% $ 260 / 5 x 10 mLAt stated conc. by weight 10 comps.

    p-Xylene Impurity Standardwith ISTDD-3798-IS $ 30 / 1 x 1 mLD-3798-IS-PAK SAVE 33% $ 100 / 5 x 1 mL

    At stated conc. by weight 11 comps.

    AccuStandards R & D team has developed a special highly purified p-Xylene designed for ASTM MethodD-3798 specifications. The incorporation of this p-Xylene into the formulation allows the analytical chemistto qualitatively and quantitatively measure the impurities in the p-Xylene feedstock streams.

    Wt./Wt. %n-Pentane 0.15n-Octane 0.15Benzene 0.15Toluene 0.15Ethylbenzene 0.15

    p-Xylene 98.65m-Xylene 0.15

    Wt./Wt. %o-Xylene 0.15Cumene 0.15Propylbenzene 0.15

    Total Analytes 100plus n-Undecane* (ISTD) 0.500grams

    Wt./Wt. %n-Pentane 0.15n-Octane 0.15Benzene 0.15Toluene 0.15Ethylbenzene 0.15

    Wt./Wt. %p-Xylene 98.65m-Xylene 0.15o-Xylene 0.15Cumene 0.15Propylbenzene 0.15

    ASTM D-2887-99 Boiling Range Distribution of Petroleum Fractions by GCCalibration Solution *DRH-002S-R1 $ 50 / 1 x 1 mLDRH-002S-R1-PAK SAVE 20% $ 200 / 5 x 1 mLAt stated conc. in Chloroform 17 comps.

    g/mLn-Hexane 600n-Heptane 600n-Octane 800n-Nonane 800n-Decane 1200

    g/mLn-Undecane 1200n-Dodecane 1200n-Tetradecane 1200n-Hexadecane 1000

    NEW

    g/mLn-Octadecane 500n-Eicosane 200n-Tetracosane 200n-Octacosane 100

    g/mLn-Dotriacontane 100n-Hexatriacontane 100n-Tetracontane 100n-Tetratetracontane100

    * Can be shipped by Air and Sea

    ASTM

    Member

    Originally designed forD-3710-95

    Originally designed forD-3831-98

  • 5/25/2018 Petroleum Standards

    27/116

    ASTM D-4291 (Reapproved 1998) Trace Ethylene Glycol in Used Engine Oil

    ASTM D-4059 Polychlorinated Biphenyls in Insulating Liquids by GC

    Fax 203-786-5287 Toll Free 800-442-5290 / 203-786-5290 Website www.accustandard.com

    Memb

    Meth

    Additional Aroclors an

    PCB Congener Standaavailable in our OrganCatalog

    Ethylene Glycol Stock StandardD-4291-93 $ 20 / 1 x 1 mLD-4291-93-PAK SAVE 20% $ 80 / 5 x 1 mL

    Ethylene glycol @ 2000 g/mL in water

    PAK Cat. No.

    Aroclor 1016 C-216N $ 25 / 100 mg 100 mg

    Aroclor 1221 C-221N 25 / 100 mg 100 mg

    Aroclor 1232 C-232N 25 / 10 mg 10 mg

    Aroclor 1242 C-242N 25 / 100 mg 100 mg

    Aroclor 1248 C-248N 25 / 10 mg 10 mg

    Aroclor 1254 C-254N 25 / 100 mg 100 mg

    Aroclor 1260 C-260N 25 / 100 mg 10 mg

    Aroclor 1262 C-262N 25 / 100 mg 10 mg

    Aroclor 1268 C-268N 25 / 10 mg 10 mgKit of above 9 Aroclors Z-008 $ 125 / 9 vials

    Z-008

    Aroclor # Cat. No. Price / Unit (Kit)

    Neat Individual Aroclors

    5 x 1 mLPrice

    Aroclor 1016 50 C-216-ST-1 $ 25 C-216-ST-1-PAK $ 90

    Aroclor 1016 500 C-216-ST-2 30 C-216-ST-2-PAK 120Aroclor 1221 50 C-221-ST-1 25 C-221-ST-1-PAK 90Aroclor 1221 500 C-221-ST-2 30 C-221-ST-2-PAK 120

    Aroclor 1232 50 C-232-ST-1 25 C-232-ST-1-PAK 90Aroclor 1232 500 C-232-ST-2 30 C-232-ST-2-PAK 120

    Aroclor 1242 50 C-242-ST-1 25 C-242-ST-1-PAK 90Aroclor 1242 500 C-242-ST-2 30 C-242-ST-2-PAK 120

    Aroclor 1248 50 C-248-ST-1 25 C-248-ST-1-PAK 90Aroclor 1248 500 C-248-ST-2 30 C-248-ST-2-PAK 120

    Aroclor 1254 50 C-254-ST-1 25 C-254-ST-1-PAK 90Aroclor 1254 500 C-254-ST-2 30 C-254-ST-2-PAK 120

    Aroclor 1260 50 C-260-ST-1 25 C-260-ST-1-PAK 90Aroclor 1260 500 C-260-ST-2 30 C-260-ST-2-PAK 120

    Aroclor 1262 50 C-262-ST-1 25 C-262-ST-1-PAK 90Aroclor 1262 500 C-262-ST-2 30 C-262-ST-2-PAK 120

    Aroclor 1268 50 C-268-ST-1 25 C-268-ST-1-PAK 90

    Aroclor 1268 500 C-268-ST-2 30 C-268-ST-2-PAK 120

    Cat. No.

    1 x 1 mLPrice

    Conc.(ppm w/w)

    Aroclor #

    ASTM Standards

    ASTM D-4294 Sulfur in Petroleum Products by ED-XRF Spectroscopy

    ASTM D-4377 Water in Crude oils by Potentiometric Karl Fischer Titration

    D-4294Meets

    EPAGuidelines

    forRFG

    Analysis

    Aroclor-free transformer oil

    also available as:

    T-W130 $ 5 / 1 x 1 mL

    See page 8-11 for AccuStandards comprehensive line of Certified Sulfur Calibration Standardsdesigned for matrix specific applications as described in Method D-4294 in section 9.0(Calibration & Standardization).

    See page 5 for AccuStandards comprehensive line of Certified Karl Fischer Water Standards.

    Aroclors in PCB-Free Transformer Oil (At 2 concentrations in Transcrest W130)

    Originally designed forD-4059-96

    Originally designed forD-4291-93

  • 5/25/2018 Petroleum Standards

    28/116

    ASTM D-4628 Barium, Calcium, Magnesium & Zinc in Unused Lubricating Oil

    ASTM D-4420 Aromatics in Finished Gasolines by GC

    22 Quality System is Certified to comply with the International ISO 9001 Quality Standard

    Method 4420

    4628

    ,

    Ready-to-Inject Petrochemical Standardsand Calibration Curves

    Reduce Costs

    Increase Time Spent for Sample AnalysisAre Validated Against Independent Lots

    Include Internal Standards or Surrogates

    Follow ASTM Method Guidelines

    Allow Direct Transfer to Autosampler Vials

    See Table of Contents for thWear Metals Group pages.

    Standards of Interests

    Vol. %n-Butylbenzene(C9 + aromatics) 15.00

    Isooctane 57.00

    Vol. %Benzene 3.00Toluene 10.00Total Xylenes (C8 aromatics) 15.00

    Aromatics in Gasoline by GC/TCD-4420-CAL-SET $ 105 / set of 7 x 1 mL

    Analyte Std. 1 Std. 2 Std. 3 Std. 4 Std. 5 Std. 6 Std. 7Target Target Target Target Target Target Target

    Vol. % Vol. % Vol. % Vol. % Vol. % Vol. % Vol. %Benzene 0.05 0.10 0.25 0.75 1.25 2.50 5.00Toluene 0.5 1.00 2.50 5.00 10.00 15.00 25.00Total Xylenes (C8 aromatics) 5 10.00 15.00 20.00 25.00 1.00 3.00

    n-Butylbenzene (C9 + aromatics) 30.00 25.00 20.00 10.00 5.00 15.00 2.50

    Isooctane 64.45 63.90 62.25 64.25 58.75 66.50 64.50

    Aromatics in Gasoline by GC/TXD-4420-94 $ 20 / 1 x 1 mLD-4420-94-PAK $ 80 / 5 x 1 mL

    5 comps.

    ASTM Standards

    Cross Reference TableASTM IP ISO DIN JIS AFNOR sorted by

    ASTM Method see beginning of Catalog

    Lubricating Oil, Elements (Nominal Value) Wt.% listed belowASTM-P-0113-SET $ 2850 / 17 x 100 mL

    Ba Ca Mg P S ZnCat. No. (Wt.%) (Wt.%) (Wt.%) (Wt.%) (Wt.%) (Wt.%)

    ASTM-P-0113-01 0.025 0.600 0.100 0.005 0.175 0.060ASTM-P-0113-02 0.000 0.500 0.150 0.200 0.050 0.080ASTM-P-0113-03 0.100 0.400 0.350 0.150 0.300 0.180ASTM-P-0113-04 0.175 0.260 0.225 0.250 0.150 0.120ASTM-P-0113-05 0.150 0.005 0.450 0.005 0.450 0.070ASTM-P-0113-06 0.000 0.400 0.500 0.025 0.350 0.100ASTM-P-0113-07 0.100 0.300 0.325 0.060 0.250 0.120ASTM-P-0113-08 0.200 0.200 0.250 0.100 0.450 0.100ASTM-P-0113-09 0.050 0.060 0.100 0.080 0.300 0.130ASTM-P-0113-10 0.075 0.060 0.400 0.050 0.200 0.050ASTM-P-0113-11 0.010 0.050 0.300 0.120 0.100 0.075ASTM-P-0113-12 0.000 0.025 0.200 0.150 0.200 0.130ASTM-P-0113-13 0.175 0.005 0.375 0.200 0.400 0.150ASTM-P-0113-14 0.005 0.170 0.175 0.250 0.550 0.110ASTM-P-0113-15 0.000 0.100 0.425 0.100 0.200 0.200ASTM-P-0113-16 0.005 0.010 0.275 0.010 0.600 0.250ASTM-P-0113-17 0.000 0.000 0.000 0.000 0.000 0.000

    ASTM

    Member

    Originally designed forD-4420-94

    Originally designed forD-4628-97

    WEARMETALS

  • 5/25/2018 Petroleum Standards

    29/116

    ASTM D-4629 Trace Nitrogen in Liquid Petroleum Hydrocarbons by Syringe/Inlet OxidativeCombustion and Chemiluminescence Detection. IP Designation 379/88

    Fax 203-786-5287 Toll Free 800-442-5290 / 203-786-5290 Website www.accustandard.com

    Memb

    Meth

    Nitrogen introduced using Pyridine

    Technical Note

    Nitrogen Calibration Set-High Boiling SolventsD-4629-91-HB-CAL-SET $ 75 / set of 7 x 1 mL

    Set includes the following Cat. No.s

    Cat. No. Description Price / Unit

    D-4629-91-HB-0.3X Nitrogen @ 0.3 g/mL in Toluene $ 20 /1 x 1 mLD-4629-91-HB-1X Nitrogen @ 1 g/mL in Toluene $ 20 /1 x 1 mLD-4629-91-HB-10X Nitrogen @ 10 g/mL in Toluene $ 20 /1 x 1 mLD-4629-91-HB-25X Nitrogen @ 25 g/mL in Toluene $ 20 /1 x 1 mLD-4629-91-HB-50X Nitrogen @ 50 g/mL in Toluene $ 20 /1 x 1 mLD-4629-91-HB-75X Nitrogen @ 75 g/mL in Toluene $ 20 / 1 x 1 mLD-4629-91-HB-100X Nitrogen @ 100 g/mL in Toluene $ 20 /1 x 1 mL

    Nitrogen introduced using Carbazole

    Technical Note

    Nitrogen introduced using Aniline

    Technical Note

    The Nitrogen is introduced using Aniline and theSulfur is introduced using di-n-Butyl sulfide

    Technical NoteLow level Nitrogen &Sulfur Calibration SetASTM-P-0071-SET $ 50 / 4 x 1 mL

    Set includes the following Cat. No.s

    Cat. No. Description Unit

    ASTM-P-0071-BL Benzene Blank 1 x 1 mLASTM-P-0071-01 Nitrogen @ 0.25 g/g & Sulfur @ 0.25 g/g in Benzene 1 x 1 mLASTM-P-0071-02 Nitrogen @ 0.50 g/g & Sulfur @ 0.50 g/g in Benzene 1 x 1 mLASTM-P-0071-03 Nitrogen @ 1.00 g/g & Sulfur @ 1.00 g/g in Benzene 1 x 1 mL

    Low level Nitrogen Calibration SetASTM-P-0070-SET $ 75 / 6 x 1 mL

    Set includes the following Cat. No.s

    Cat. No. Description Unit

    ASTM-P-0070-BL Isooctane Blank 1 x 1 mLASTM-P-0070-1X Nitrogen @ 0.5 g/g in Isooctane 1 x 1 mL

    ASTM-P-0070-2X Nitrogen @ 1.0 g/g in Isooctane