personas m series - money handling · pdf filencr personas m series 5886 drive-up site...

264
Personas M Series 5886 Drive-Up Site Preparation and Installation B006-6328-F000 1204

Upload: phamdat

Post on 05-Feb-2018

227 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Personas M Series5886 Drive-UpSite Preparation and Installation

B006-6328-F0001204

Page 2: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NOTICE

This is a contractual document. It contains important warning and confers important legal rights and obligations. You are advised to read it carefully.

It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with all specifications and requirements of NCR and all applicable national, state, or local codes, regulations and laws.

The product described in this book is a licensed product of NCR Corporation.

APTRATM and PersonasTM are trademarks of NCR Corporation

It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available. NCR, therefore, reserves the right to change specifications without prior notice.

All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office for information that is applicable and current.

To maintain the quality of our publications, we need your comments on the accuracy, clarity, organization, and value of this book.

Address correspondence to:

NCR Financial Solutions Group LtdInformation SolutionsKingsway WestDundee,ScotlandDD2 3XX

© 2001, 2002, 2003, 2004By NCR CorporationDayton, Ohio U.S.A.All Rights Reserved

Page 3: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

iii

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Federal Communications Commission (FCC) Radio Frequency Interference Statement

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Canadian Class A Device Declaration

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.

Information to UserThis equipment must be installed and used in strict accordance with the manufacturer’s instructions. However, there is no guarantee that interference to radio communications will not occur in a particular commercial installation. If this equipment does cause interference, which can be determined by turning the equipment off and on, the user is encouraged to consult an NCR service representative immediately.

Caution NCR Corporation is not responsible for any radio or television interference caused by unauthorised modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by NCR. Such unauthorized modifications, substitutions, or attachments may void the user’s authority to operate the equipment. The correction of interference caused by such unauthorized modifications, substitutions, or attachments will be the responsibility of the user.

Page 4: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

iv NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 5: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

v

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Revision Record

Revision Record

Date Page Description of Change

Aug 02 All New Publication for Personas 86 Drive-Up

Sept. 03 All Update to include Cash Acceptor and Cheque AcceptorTitle change from Personas 86 to Personas M Series 5886

Sept. 03 All Revision B: update to include short sleeve

Feb. 03 All Revision C: update to remove disclaimer relating to Cheque Acceptor, changes to severe environment and short sleeve height requirements

July 04 Chap 1 Revision D: update for new dispenser slides

Sept. 04 Chaps 9 & 10

Revision E: update to include new statement printer (type 2).

Dec. 04 Chap 1& Chap 9

Revision F: update to ‘Installation and Service Clearance’ section and for left-hand side envelope depository

Page 6: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

vi NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 7: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Contents

Table of Contents

vii

NCR Personas M Series 5886 Site Preparation and Installation

Preface .....................................................................................................xiiiSite Preparation ...............................................................................xiiiInstallation .......................................................................................xivOverview..........................................................................................xivCustomer Responsibilities ..............................................................xvProduct Identification.....................................................................xvi

Chapter 1Physical Requirements

Package Dimensions .............................................................................1-1Manoeuvring the ATM Into Position...........................................1-2

ATM Dimensions ..................................................................................1-4Standard Sleeve Before Collar has Been Fitted...........................1-5Short Sleeve Before Collar has Been Fitted .................................1-6Standard Collar ...............................................................................1-7Standard Collar With Advert Light .............................................1-8Severe Environment Fitted ............................................................1-9Cheque Acceptor Fitted ...............................................................1-10Heights to Main Facia Items........................................................1-11Ambient Lighting..........................................................................1-12

Installation and Service Clearances ..................................................1-13Recommended Clearances...........................................................1-13Minimum Clearances ...................................................................1-17Exterior Wall..................................................................................1-26

Service Access Panels..........................................................................1-28Hole in the Wall ...................................................................................1-29

Installation Categories..................................................................1-29Installing Through a Glass Wall .................................................1-29

Replacing 5088 With Modifications to Hole in Wall ......................1-30Dimensions for an ATM With Standard Sleeve .......................1-30Dimensions for an ATM With Short Sleeve ..............................1-31

Page 8: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of Contents

Plinth Requirements .....................................................................1-31Replacing 5688 With no Modifications to the Hole in Wall ..........1-32

Dimensions for an ATM With Standard Sleeve .......................1-32Dimensions for an ATM With Short Sleeve ..............................1-33Plinth Requirements .....................................................................1-33

Installing Through a New Hole.........................................................1-34Dimensions for an ATM With Standard Sleeve .......................1-34Dimensions for an ATM With Short Sleeve ..............................1-35Plinth Requirements .....................................................................1-35

Sealing the Hole in the Wall Against Cold and Water...................1-36Requirements for the Floor ................................................................1-37

Support Plinth ...............................................................................1-37Mandatory Modifications to Plinth or Floor ...................................1-40

Concrete Plinth ..............................................................................1-40Adjustable Plinth...........................................................................1-40ATM Installed Directly on to the Floor......................................1-40Floor Loading ................................................................................1-42Security Bolts .................................................................................1-42Floor Covering...............................................................................1-42

Infill Panel Dimensions.......................................................................1-43Infill Panel (5088) ..........................................................................1-43Infill Panel (5688) ..........................................................................1-44

Internal Space Constraint for Fitting a Third Party Video Camera ...............................................................................................1-45

Chapter 2Electrical Requirements

Power Quality Distribution and Grounding Requirements ...........2-1AC Power Requirements ...............................................................2-1Input Voltage Setting......................................................................2-1Power Consumption.......................................................................2-1Power Cable .....................................................................................2-2Grounding Requirements ..............................................................2-2Transient Power Loss .....................................................................2-3EMI Susceptibility ...........................................................................2-3EMI Emission...................................................................................2-3

Communications Requirements ..........................................................2-4High Order Communications Cable ............................................2-4Remote Device Cables ....................................................................2-6

viii NCR Personas M Series 5886 Site Preparation and Installation

Page 9: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of Contents

Chapter 3Environmental Requirements

Environmental Requirements..............................................................3-1Temperature and Humidity ..........................................................3-1Barometric Pressure........................................................................3-2Electromagnetic Compatibility (EMC) and Safety.....................3-4Acoustics ..........................................................................................3-4Heat Dissipation..............................................................................3-4Air Flow............................................................................................3-4Temperature Rise ............................................................................3-4

Chapter 4Decal Requirements

Decal Dimensions ..................................................................................4-1Card Orientation Window.............................................................4-2Card Acceptance Decal ..................................................................4-3Clear Window .................................................................................4-3Advert Light ....................................................................................4-4Entry/Exit Slot Decals....................................................................4-5

Chapter 5Installation Accessories and Planning Check List

Installation Accessories ........................................................................5-1Planning Check List ..............................................................................5-2

Chapter 6Installation Procedure

Introduction............................................................................................6-1Installation Steps .............................................................................6-1Site Preparation ...............................................................................6-1Tools Required For ATM Installation ..........................................6-1Moving the ATM.............................................................................6-2

NCR Personas M Series 5886 Site Preparation and Installation ix

Page 10: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of Contents

Chapter 7Preparing the ATM For Installation

Removing the External Packaging From the ATM...........................7-1Inspecting the ATM For Damage .................................................7-1Installation Report Form................................................................7-2

Opening the ATM..................................................................................7-3How to Open the ATM ..................................................................7-3

How to Unlock and Lock the Standard Security Enclosure............7-5Keylocks ...........................................................................................7-6Combination Locks .........................................................................7-6Combination Lock and Separate Keylock ...................................7-8

How to Unlock and Lock an Electronic Lock ..................................7-12Unlocking .......................................................................................7-12Locking ...........................................................................................7-13Emergency Opening Procedure..................................................7-14

How to Unlock and Lock a Controlled Access Electronic Lock ...7-15Controlled Access Electronic Lock (Type 1) .............................7-16Controlled Access Electronic Lock (Type 2) .............................7-18

Removing the ATM From Its Pallet ..................................................7-24

Chapter 8Installing the ATM – Physical Installation

Introduction............................................................................................8-1Installation Categories....................................................................8-1Connecting Cables ..........................................................................8-1

Fitting the Severe Environment Parts.................................................8-2Dismantling the Severe Environment Parts ................................8-2Removing the 80-Column Printer.................................................8-4Removing the Side-Access Service Panel ....................................8-7Fitting the Severe Environment Parts ........................................8-11Sealing the ATM............................................................................8-17

Fitting a Cheque Acceptor Bin (If Configured)...............................8-22Cheque Acceptor Bin With a Keylock........................................8-22Cheque Acceptor Bin With a Sub-Lock .....................................8-24

Positioning the ATM...........................................................................8-27Fitting An Infill Panel..........................................................................8-28

Infill Panel (5088) ..........................................................................8-28Infill Panel (5688) ..........................................................................8-29

Fitting the Collar ..................................................................................8-31

x NCR Personas M Series 5886 Site Preparation and Installation

Page 11: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of Contents

Fitting the Standard Collar With Facia Light............................8-31Fitting the Standard Collar With Advert Light ........................8-36

Sealing the Collar and Bolting the ATM to the Plinth ...................8-44

Chapter 9Installing the ATM – Internal Packaging and Cables

Removing the Internal Packaging.......................................................9-1Module Locations ..........................................................................9-2Top-Box ............................................................................................9-3Security Enclosure ..........................................................................9-4Operator Panel ................................................................................9-5Currency Dispenser ........................................................................9-6PC Core.............................................................................................9-8Magnetic Card Reader/Writer......................................................9-9Receipt and Journal Printers .......................................................9-1080 Column Printer Release Latch................................................9-11Statement Printer ..........................................................................9-12Depository and Depository Bin ..................................................9-14Cash Acceptor ...............................................................................9-16Cheque Acceptor...........................................................................9-17

Connecting Cables to the ATM .........................................................9-18Power Cable...................................................................................9-18Connecting All Other Cables ......................................................9-21

Chapter 10Configuring the ATM

Introduction..........................................................................................10-1Currency Cassette Configuration......................................................10-2Device Configuration..........................................................................10-3Communications Configuration .......................................................10-4

Self-Service Support .....................................................................10-4S4I ....................................................................................................10-4

Currency Dispenser Configuration ..................................................10-5Strapping........................................................................................10-5

Currency Cassette Configuration......................................................10-640-Column Printer Configuration.....................................................10-7

Thermal Receipt and Journal Printers........................................10-7Basic Configuration ......................................................................10-8Advanced Configuration and Calibration ................................10-8Dot-Matrix Journal Printer ........................................................10-12

NCR Personas M Series 5886 Site Preparation and Installation xi

Page 12: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of Contents

80-Column Printer Configuration...................................................10-13Adjusting DIP Switch Settings ..................................................10-14Adjusting Jumper JP1 (Type 2 Printer only) ...........................10-16Adjusting Hopper Paper Guides ..............................................10-16Adjusting the Contrast ...............................................................10-22Capture Bin Threshold ...............................................................10-23

Envelope Dispenser...........................................................................10-24Adjusting the Spacer Length .....................................................10-28

Chapter 11Fitting Decals to the ATM

Fitting the Decals .................................................................................11-1Advert Light ..................................................................................11-1Card Orientation Window and Clear Window ........................11-1Entry/Exit Decals..........................................................................11-2Card Acceptance Decal ................................................................11-2

Appendix ATransient and Power Protection

AC Power Line Transient Protection .................................................A-1Data Line Transient Protection...........................................................A-3NCR Power Protection and Cabling Products .................................A-4

AC Power Line Transient Protection ..........................................A-4Data Line Transient Protection ....................................................A-5Uninterruptible Power Supplies ..................................................A-5Contact Information ......................................................................A-7

IndexIndex................................................................................................Index-1

User Feedback Form

xii NCR Personas M Series 5886 Site Preparation and Installation

Page 13: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

iii

xNCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Preface

Preface

Site PreparationChapter 1 to Chapter 5 of this document contain the information necessary for the preparation of a site conforming to NCR specifications. It is very important that the site complies with the requirements specified these chapters because, once the equipment has been installed, deficiencies in site preparation or the problems caused by these deficiencies are much more difficult to detect and correct. Further, failure to comply with these requirements or to take proper steps to protect equipment against risks identified in this document may cause serious damage to the equipment and to the customer’s business.

In addition to the need to comply with the requirements specified, electrical wiring and mechanical systems must also comply with all relevant codes, laws and regulations.

It is important that the site be prepared by a customer or his agent who is fully conversant with the special requirements of electronic equipment. The responsibility for ensuring that the site is prepared in compliance with this document remains with the customer.

For information and guidance only, a list is provided, in general terms, of those matters for which the customer is responsible. This list is not intended to be comprehensive, and in no way modifies, alters, or limits the responsibility of the customer for all aspects of adequate site preparation.

NCR staff will be available to answer questions relating to the contents of the chapters but, except where:

a the customer has been notified that a full or partial consultancy service is available and/or that NCR will be willing to undertake a preliminary or final site survey and

b the customer shall have entered into a formal contract with NCR for provision of the same.

No comment, suggestion or advice offered or not offered about preparation of the site nor any inspection of the site whether before or after preparation is to be taken as approval of the location of the site and equipment or of its preparation and NCR will not be liable in respect of any comment, suggestion or advice given by its staff or in respect of any failure to give advice.

Finally, only the customer can know the full extent of damage which may be caused to his business by reason of failure of the equipment which is to be installed. For this reason it is the customer’s responsibility to ascertain the extent of any such possible damage to his existing or planned business, and to effect full insurance in respect of it.

Page 14: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preface

InstallationChapter 6 to Chapter 11 are intended for NCR personnel or NCR customer personnel who are required to install an NCR 5886 Drive-Up Automated Teller Machine (ATM).

The chapters describe how to move the ATM from its point of delivery and install it in the required location.

The procedures are presented in six chapters with the following contents:

● Chapter 6 lists the steps and tools required to install an ATM, and details how to move the ATM to the installation site

● Chapter 7 describes how to unpack the ATM and remove it from its pallet

● Chapter 8 describes the installation of the ATM through the hole in the wall

● Chapter 9 describes how to remove the internal packaging and how to connect cables

● Chapter 10 describes the configuration procedure● Chapter 11 describes how to fit decals to the front of the ATM.

The procedures, from Chapter 6 to Chapter 10, must be followed in sequence. The procedures in Chapter 11 can be carried out at any time, before or after the installation of the ATM.

Overview The NCR Personas M Series 5886 Drive-Up Automated Teller Machine (ATM) is a self-service ATM which may be installed through any suitable exterior wall or kiosk, in the first drive-up lane.

This publication is specific to Drive-Up. For the Walk-Up version, refer to the publication ‘Personas M Series 5886 Site Prep Manual’ (B006-6191) or ‘Personas M Series 5886 Installation Manual’ (B006-6193).

The 5886 is available as:

● Walk-Up ● short sleeve (UL security enclosure only) ● standard sleeve.

● Drive-Up (UL security enclosure only)● short sleeve ● standard sleeve.

The ATM is designed to provide a range of services such as:

● Cash withdrawals● Statement printing● Cheque book requests

xiv NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 15: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preface

● Account enquiries ● Transfers● Envelope deposits● Envelope dispensing● Cheque Deposits● Cash Deposits.

Customer ResponsibilitiesThe customer must do or provide the following:

● When required by NCR, provide the NCR customer service representative with appropriate drawings that indicate: ● Location of the equipment● Site wiring (power and signal, paths and lengths) ● Location of other equipment capable of generating electrical

noise, electromagnetic interference, heat, etc.● Make building alterations necessary to meet wiring and other

site requirements.● Provide and install all communications cables, wall jacks,

special connectors, and associated hardware.● Provide and install necessary power distribution boxes,

conduits, grounds, lightning protection, and associated hardware.

● Make sure all applicable codes, regulations and laws (including, but not limited to, electrical, building, safety, and health) are met.

● Provide and install auxiliary power or other equipment as required.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation xv

Page 16: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preface

● Provide storage or service areas as required.● Make sure the environmental requirements of the system/unit

are met.● Provide floor coverings and environmental systems that limit or

control static electricity build-up and discharge.● Install the product at a height which meets the accessibility

regulations of the relevant country.

Product IdentificationThe product is identified by a class type number, 5886, and a 4 digit model number which is printed on a label fixed inside the top cabinet of the ATM and above the receipt printer. The first two digits of the model number identify the major model (normally 01), the next two digits identify the minor model (normally 01). The serial number is unique to each ATM. The tracer number is used to identify where the ATM was built. Please quote all of the serial and tracer numbers, including the prefix, when making reference to the ATM.

Model: XXXX

Hz: 50/60 A:6.3

Serial: XX-XXXXXXXX

Tracer: XX-XXXXX

Vac: 220 - 240

NCR Global Soltutions Ltd.

Made in UK

Electromagnetic Compatibility

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interferencereceived, including interference that may cause undesired operation.

This apparatus does not exceed Class A limits for radio noise emissions set out in the Radio InterferenceRegulations of Canada.

‘’Complies with FDA Radiation Performance Standards, 21 CFR Subchapter J’‘

Le present appariel n’emet pas de bruits radioelectriques depassant les limites de la classe A prescritesdans le Reglement sur le brouillage radioelectrique du Canada.

Class: 5886

LR 32207

LISTED649Automated Teller Machine24 Hour Service Level 1

UL

xvi NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 17: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsPhysical Requirements

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Chapter 1

Physical Requirements

Package Dimensions 1-1Manoeuvring the ATM Into Position 1-2

ATM Dimensions 1-4Standard Sleeve Before Collar has Been Fitted 1-5Short Sleeve Before Collar has Been Fitted 1-6Standard Collar 1-7Standard Collar With Advert Light 1-8Severe Environment Fitted 1-9Cheque Acceptor Fitted 1-10Heights to Main Facia Items 1-11

Topmost Viewable Facia Item 1-12Ambient Lighting 1-12

Installation and Service Clearances 1-13Recommended Clearances 1-13

Important Notice to Users 1-13Standard Sleeve Recommended Clearances 1-14Short Sleeve Recommended Clearances 1-15

Minimum Clearances 1-17Important Notice to Users 1-17Standard Sleeve Minimum Clearances (Envelope

Depository Module and/or Currency Dispenser) 1-18Short Sleeve Minimum Clearances (Envelope

Depository Module and/or Currency Dispenser) 1-20Standard Sleeve Minimum Clearance (Cheque Acceptor

(Type 2) and/or Cash Acceptor (UD-686), or Dual Dispenser) 1-22

Exterior Wall 1-26Standard Collar 1-26Standard Collar With Advert Light 1-27

Service Access Panels 1-28

Hole in the Wall 1-29

Page 18: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsPhysical Requirements

Installation Categories 1-29Installing Through a Glass Wall 1-29

Replacing 5088 With Modifications to Hole in Wall 1-30Dimensions for an ATM With Standard Sleeve 1-30Dimensions for an ATM With Short Sleeve 1-31Plinth Requirements 1-31

Replacing 5688 With no Modifications to the Hole in Wall 1-32Dimensions for an ATM With Standard Sleeve 1-32Dimensions for an ATM With Short Sleeve 1-33Plinth Requirements 1-33

Installing Through a New Hole 1-34Dimensions for an ATM With Standard Sleeve 1-34Dimensions for an ATM With Short Sleeve 1-35Plinth Requirements 1-35

Sealing the Hole in the Wall Against Cold and Water 1-36

Requirements for the Floor 1-37Support Plinth 1-37

Standard Sleeve Installation 1-38Short Sleeve Installation 1-39

Mandatory Modifications to Plinth or Floor 1-40Concrete Plinth 1-40Adjustable Plinth 1-40ATM Installed Directly on to the Floor 1-40Floor Loading 1-42Security Bolts 1-42Floor Covering 1-42

Infill Panel Dimensions 1-43Infill Panel (5088) 1-43Infill Panel (5688) 1-44

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 19: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsPhysical Requirements

Internal Space Constraint for Fitting a Third Party Video Camera 1-45

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 20: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsPhysical Requirements

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 21: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1

-1

Package DimensionsPhysical Requirements1

Package Dimensions 1

The dimensions of a packaged ATM are shown below.

Page 22: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsPackage Dimensions

Manoeuvring the ATM Into Position 1

Ensure that doorways and corridors leading to your point of installation are wide enough to allow the package to pass through, or make arrangements to unpack the ATM in an area with sufficient access and then move it to the installation site. Also ensure that any corridors can support the weight of the ATM.

The following table shows the minimum dimensions for doorways, corridors with right angle corners and the space required to rotate an ATM on its axis.

Note 1: The dimensions assume the ATM is being moved using equipment that does not extend beyond the base of the ATM or packaging.

Note 2: A surrounding clearance of 6 mm (0.25 in.) has been allowed in the figures.

1-2 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 23: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsPackage Dimensions

Unpackaged ATM(Standard Sleeve)

Unpackaged ATM(Short Sleeve)

Packaged ATM

A Doorway or straight corridor

827 mm (32.56 in.)

827 mm (32.56 in.)

1007 mm (39.65 in.)

B Corridor with corner

1009 mm (39.72 in.)

969 mm(38.15 in.)

1221 mm (48.07 in.)

C Rotation about centre

1455 mm (57.28 in.)

1363 mm(53.66 in.)

1754 mm (69.06 in.)

A B

B

C

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-3

Page 24: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

ATM Dimensions 1

The following illustrations show dimensions for ATM’s configured with UL security enclosures.

Note: Cables enter the ATM through the hole in the base of the ATM security enclosure. The location of the hole is shown in the illustration “Support Plinth” (see page 1-29).

1-4 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 25: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

Standard Sleeve Before Collar has Been Fitted 1

The dimensions in the illustration below show the ATM before a collar has been fitted.

1257.0 mm(49.49 in.)

350.7 mm(13.81 in.)

4.8 mm(0.19 in.)

511.0 mm(20.12 in.)

515.6 mm(20.30 in.)

1105.0 mm(43.50 in.)

815.0 mm(32.09 in.)

835.0 mm(32.87 in.)

1185.7 mm(46.68 in.)

804.7 mm(31.68 in.)

55.0 mm(2.17 in.)

160.0 mm(6.30 in.)

600.0 mm(23.62 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-5

Page 26: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

Short Sleeve Before Collar has Been Fitted 1

The dimensions in the illustration below show the ATM before a collar has been fitted.

1257.0 mm(49.49 in.)

237.4 mm(9.35 in.)

4.8 mm(0.19 in.)

511.0 mm(20.12 in.)

515.6 mm(20.30 in.)

1105.0 mm(43.50 in.)

815.0 mm(32.09 in.)

835.0 mm(32.87 in.)

1072.4 mm(42.22 in.)

804.7 mm(31.68 in.)

55.0 mm(2.17 in.)

160.0 mm(6.30 in.)

600.0 mm(23.62 in.)

1-6 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 27: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

Standard Collar 1

The dimensions in the illustration below show a standard sleeve ATM with a standard collar fitted.

Note: For short sleeve terminals, this dimension is 209.4 mm (8.24 in.)

1257.0 mm(49.49 in.)

511.0 mm(20.12 in.)

37.5 mm(1.48 in.)

322.7 mm(12.70 in.)See Note

715.0 mm(28.15 in.)

1175.3 mm(46.27 in.)

464.9 mm(18.30 in.)

815.0 mm(32.09 in.)

835.0 mm(32.87 in.)

804.7 mm(31.68 in.)

55.0 mm(2.17 in.)

160.0 mm(6.30 in.)

600.0 mm(23.62 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-7

Page 28: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

Standard Collar With Advert Light 1

The dimensions in the illustration below show a standard sleeve ATM with a standard collar with advert light fitted.

Note: For short sleeve terminals, this dimension is 209.4 mm (8.24 in.)

1338.3 mm(52.69 in.)

511.0 mm(20.12 in.)

37.5 mm(1.48 in.)

322.7 mm(12.70 in.)See Note

1257.0 mm(49.49 in.)

715.0 mm(28.15 in.)

464.9 mm(18.30 in.)

815.0 mm(32.09 in.)

835.0 mm(32.87 in.)

804.7 mm(31.68 in.)

55.0 mm(2.17 in.)

160.0 mm(6.30 in.)

600.0 mm(23.62 in.)

1-8 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 29: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

Severe Environment Fitted 1

The dimensions in the illustration below show the ATM with severe environment fitted.

224.0 mm(8.82 in.)

82.2 mm(3.24 in.)

248.0 mm(9.76 in.)

188.1 mm(7.41 in.)

452.0 mm(17.80 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-9

Page 30: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

Cheque Acceptor Fitted 1

The dimensions in the illustration below show the ATM with a cheque bin when a cheque acceptor has been fitted.

230.5 mm(9.07 in.)

144.0 mm(5.67 in.)

224.3 mm(8.83 in.)

285.5 mm(11.24 in.)

134.0 mm(5.28 in.)

Without Bin

92.5 mm(3.64 in.)

540.6 mm21.28( in.)

16.5 mm(0.65 in.)

15.0 mm0.59( in.)

1-10 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 31: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

Heights to Main Facia Items 1

The following table gives the heights and depths to the main facia items, located on the 5886 Drive-Up facia. All the height dimensions are calculated from road level and are based on the ATM being installed at the optimum height, given in the “Hole In The Wall” section later in this chapter.

Height(from Road Level)

Depth(from front of Collar)

A Statement 1317.7 mm (51.88 in.) 151.0 mm (5.94 in.)

I 1207.8 mm (47.55 in.) 138.0 mm (5.43 in.)Card Reader, Motorised

E 1023.6 mm (40.30 in.) 116.0 mm (4.57 in.)Cash Exits 1 & 2

Audio Jack Plug

M

1108.4 mm (43.64 in.) 105.0 mm (4.13 in.)

B 1171.7 mm (46.13 in.)Display 150.5 mm (5.93 in.)

C 1123.0 mm (44.21 in.)2nd Functional Display Key 120.0 mm (4.72 in.)

1090 mm (42.91 in.)1st Functional Display KeyD 115.0 mm (4.53 in.)

J 1207.0 mm (47.52 in.) 87.0 mm (3.43 in.)Card Reader, Dip

F 15.0 mm (0.59 in.)No. 5 Key 930.0 mm (36.61 in.)

1211.0 mm (47.68 in.) 130.0 mm (5.12 in.)Camera WindowK

Receipt 1294.5 mm (50.96 in.) 157.0 mm (6.18 in.)H

Speaker 1363.5 mm (53.68 in.) 178.0 mm (7.01 in.)G

Envelope/Cheque/Cash deposit 116.0 mm (4.57 in.)1017.5 mm (40.06 in.)

L

Item

A

B

C

D

E

F

G

H

I, J

M, E

L

K

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-11

Page 32: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsATM Dimensions

Topmost Viewable Facia Item 1

The following illustration shows the projected angle from the front of the standard collar to the topmost viewable facia item.

Ambient Lighting 1

If the ATM is fitted with a video camera it is strongly recommended that there is a minimum of 200 LUX lighting at floor level within the area illustrated below. This lighting level conforms to:

● Australian Standard for Automatic Teller Machines (1990) ● Lighting for Automated Teller Machines as prepared by

Illuminating Engineering Society of North America (1997).

Note: A minimum of 200 LUX is recommended for task lighting.

Statement45

1000 mm(39.4 in.)

1500 mm(59.1 in.)

1-12 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 33: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Installation and Service Clearances 1

Recommended Clearances 1

The following illustrations show the recommended areas required for installing and servicing the ATM.

Note: If the ATM is replacing a 5088 installation, the building or kiosk may need rework or replacement, as the clearance area is predominantly to the rear of the ATM.

Important Notice to Users 1

If it is likely that the ATM might be fitted with other new modules as they become available, you should use the recommended clearances.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-13

Page 34: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Standard Sleeve Recommended Clearances 1

Note 1: The height of the plinth depends upon the difference in height between road level and the interior floor. If there is no difference, as the illustration shows, the plinth must have a height of 325 mm (12.8 in.).

Note 2: If your ATM is configured with a cheque acceptor, it is recommended that the cheque acceptor bin is removed from the security enclosure door before opening the enclosure.

1737 mm(68.4 in.)

900 mm(35.4 in.)

2123 mm(83.6 in.)

1745 mm(68.7 in.)

RecommendedClearance

SeeNote 1

Plinth

461 mm(18.1 in.)

461 mm(18.1 in.)

Currency Dispenser

120

Currency Dispenser

1000 mm(39.4 in.)

1-14 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 35: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Short Sleeve Recommended Clearances 1

Note 1: The currency dispenser can be serviced without fully extending its slides, giving a dimension of 786 mm (30.9 in.) as shown. This can be achieved by pulling the slides until the nose of the currency presenter is out of the security enclosure.

Note 2: The height of the plinth depends upon the difference in height between road level and the interior floor. If there is no difference, as the illustration shows, the plinth must have a height of 325 mm (12.8 in.).

1737 mm(68.4 in.)

786 mm(30.9 in.)Minimum

See Note 1

2009 mm(79.1 in.)

1745 mm(68.7 in.)

RecommendedClearance

SeeNote 2

Plinth

461 mm(18.1 in.)

461 mm(18.1 in.)

Currency Dispenser

120

Currency Dispenser

1000 mm(39.4 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-15

Page 36: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Note 3: If your ATM is configured with a cheque acceptor, it is recommended that the cheque acceptor bin is removed from the security enclosure door before opening the enclosure.

1-16 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 37: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Minimum Clearances 1

The following illustrations show the minimum areas required for installing and servicing the ATM. Note that installing the ATM in the minimum servicing footprint may increase the servicing time for the unit.

Important Notice to Users 1

If your ATM is fitted with, or is likely to be upgraded with cheque acceptor, cash acceptor, or dual dispenser, the ATM must be sited within the minimum clearance area as shown on page 1-22. Also, if it is likely that the ATM might be fitted with other new modules as they become available, you should use the recommended clearances.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-17

Page 38: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Standard Sleeve Minimum Clearances (Envelope Depository Module and/or Currency Dispenser) 1

Minimum clearance can be achieved by offering either side clearance or rear clearance, as shown below.

Note 1: The height of the plinth depends upon the difference in height between road level and the interior floor. If there is no difference, as the illustration shows, the plinth must have a height of 325 mm (12.8 in.).

1024 mm(40.3 in.)

740 mm(29.1 in.)

111 mm(4.4 in.)

98 mm(3.9 in.)

Currency Dispenser

Envelope Depository

1585 mm(62.4 in.)MinimumClearance

See Note 2

Severe EnvironmentAir Intake

900 mm(35.4 in.)

2345 mm(92.3 in.)

1222 mm(48.1 in.)

SideClearance

RearClearance

1000 mm(39.4 in.)

1246 mm(49.1 in.)

2123 mm(83.6 in.)

SeeNote 1

Plinth

1-18 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 39: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Note 2: If your ATM is installed within the minimum height clearance of 1585 mm (62.4 in.) the ceiling will restrict the full opening of the top-box. If you want to have a clearance above the top-box when fully open, refer to the recommended clearance.

Note 3: When the ATM is installed within the minimum service clearance, the 80 Column printer must be removed to service the keyboard and shutter areas.

Note 4: Your ATM may be fitted with the severe environment option, which is shown in the illustration (see ATM Dimensions section for more information). When severe environment is configured, the 80 Column printer must be removed to service the module from the rear.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-19

Page 40: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Short Sleeve Minimum Clearances (Envelope Depository Module and/or Currency Dispenser) 1

Minimum clearance can be achieved by offering either side clearance or rear clearance, as shown below.

Note 1: The currency dispenser can be serviced without fully extending its slides, giving a dimension of 786 mm (30.9 in.) as shown. This can be achieved by pulling the slides until the nose of the currency presenter is out of the security enclosure.

1024 mm(40.3 in.)

740 mm(29.1 in.)

786 mm(30.9 in.)Minimum

See Note 1

111 mm(4.4 in.)

98 mm(3.9 in.)

Currency Dispenser

Envelope Depository

1720 mm(67.7 in.)MinimumClearance

See Note 2

Severe EnvironmentAir Intake

SideClearance

RearClearance

1246 mm(49.1 in.)

SeeNote 3

Plinth

2231 mm(87.8 in.)

2009 mm(79.1 in.)

1222 mm(48.1 in.)

1000 mm(39.4 in.)

1-20 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 41: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Note 2: If your ATM is installed without an 80 column printer fitted, the minimum height clearance is 1585 mm (62.4 in.). If installed at this height, the ceiling will restrict the full opening of the top-box. If you want to have a clearance above the top-box when fully open, refer to the recommended clearance.

Note 3: The height of the plinth depends upon the difference in height between road level and the interior floor. If there is no difference, as the illustration shows, the plinth must have a height of 325 mm (12.8 in.).

Note 4: When the ATM is installed within the minimum service clearance, the 80 Column printer must be removed to service the keyboard and shutter areas.

Note 5: Your ATM may be fitted with the severe environment option, which is shown in the illustration (see ATM Dimensions section for more information). When severe environment is configured, the 80 Column printer must be removed to service the module from the rear.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-21

Page 42: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Standard Sleeve Minimum Clearance (Cheque Acceptor (Type 2) and/or Cash Acceptor (UD-686), or Dual Dispenser) 1

Minimum clearance can be achieved by offering either side clearance or rear clearance, as shown below. However, if you have a cheque acceptor, you MUST use the side clearance dimensions.

900 mm(35.4 in.)

870 mm(34.3 in.)

256 mm(10.1 in.)

306 mm(12.0 in.)

468 mm(18.4 in.)

Currency Dispenser

Cash Acceptor

102

SeeNote 1

2345 mm(92.3 in.)

2123 mm(83.6 in.)

1441 mm(56.7 in.)

Cheque Acceptor

1222 mm(48.1 in.)

1585 mm(62.4 in.)MinimumClearance

See Note 2

SeeNote 3

Plinth

SideClearance

RearClearance

98 mm(3.9 in.)

Severe EnvironmentAir Intake

1000 mm(39.4 in.)

1219 mm(48.0 in.)

1-22 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 43: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Note 1: To allow a cheque acceptor to be serviced within the minimum service clearance area, the rear transport can be pivoted from its horizontal position to a vertical position as shown below.

Note 2: If your ATM is installed within the minimum height clearance of 1585 mm (62.4 in.) the ceiling will restrict the full opening of the top-box. If you want to have a clearance above the top-box when fully open, refer to the recommended clearance.

Note 3: The height of the plinth depends on the difference in height between road level and the interior floor. If there is no difference, as the illustration shows, the plinth must have a height of 325 mm (12.8 in.).

Note 4: If your ATM is configured with a cheque acceptor, it is recommended that the bin is removed from the security enclosure door before opening the enclosure.

870.0 mm(34.3 in.)

Cheque Acceptor

Cash Acceptor(if configured)

Rear Transport

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-23

Page 44: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Short Sleeve Minimum Clearance (Cheque Acceptor (Type 2) and/or Cash Acceptor (UD-686), or Dual Dispenser)

Minimum clearance can be achieved by offering either side clearance or rear clearance, as shown. However, if you have a cheque acceptor, you MUST use the side clearance dimensions.

786 mm(30.9 in.)Minimum

See Note 2

870 mm(34.3 in.)

256 mm(10.1 in.)

306 mm(12.0 in.)

468 mm(18.4 in.)

Currency Dispenser

Cash Acceptor

102

SeeNote 1

2231 mm(87.8 in.)

2009 mm(79.1 in.)

1441 mm(56.7 in.)

Cheque Acceptor

1222 mm(48.1 in.)

See Note 3

SeeNote 4

Plinth

SideClearance

RearClearance

98 mm(3.9 in.)

Severe EnvironmentAir Intake

1000 mm(39.4 in.)

1219 mm(48.0 in.)

1720 mm(67.7 in.)MinimumClearance

1-24 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 45: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Note 1: To allow a cheque acceptor to be serviced within the minimum service clearance area, the rear transport can be pivoted from its horizontal position to a vertical position as shown below.

Note 2: The currency dispenser can be serviced without fully extending its slides, giving a dimension of 786 mm (30.9 in.) as shown. This can be achieved by pulling the slides until the nose of the currency presenter is out of the security enclosure.

Note 3: If your ATM is installed without an 80 column printer fitted, the minimum height clearance is 1585 mm (62.4 in.). If installed at this height, the ceiling will restrict the full opening of the top-box. If you want to have a clearance above the top-box when fully open, refer to the recommended clearance.

Note 4: The height of the plinth depends on the difference in height between road level and the interior floor. If there is no difference, as the illustration shows, the plinth must have a height of 325 mm (12.8 in.).

870.0 mm(34.3 in.)

Cheque Acceptor

Cash Acceptor(if configured)

Rear Transport

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-25

Page 46: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Exterior Wall 1

The following illustrations show the minimum clear wall area required around the collar (facia surround) for installation and servicing.

Standard Collar 1

Note: A standard collar is configured when you order the 5886 Drive-Up features 240 and 770.

30 mm(1.2 in.)

30 mm(1.2 in.)

10 mm(0.4 in.)

45 mm(1.8 in.)

1-26 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 47: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstallation and Service Clearances

Standard Collar With Advert Light 1

Note: A standard collar with advert light is configured when you order the 5886 Drive-Up features 241 and 770.

30 mm(1.2 in.)

30 mm(1.2 in.)

45 mm(1.8 in.)

45 mm(1.8 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-27

Page 48: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsService Access Panels

Service Access Panels 1

For installations where there is enough room to stand at the right-hand side of the sleeve (when viewing the ATM from the rear) there is an access panel on the top-box, as shown below. The panel can be removed to allow easier access to the keyboard and shutter areas.

Note: If the severe environment feature is configured, first remove the fan assembly.

There is another access panel on the left-hand side which is only accessible if the ATM is installed through a thin wall, 97 mm (3.82 in.) or less. This panel is located on the sleeve, as shown below.

1-28 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 49: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsHole in the Wall

Hole in the Wall 1

The 5886 Drive-Up can be installed through a new hole, or an existing NCR 5088 or 5688 hole in the wall with minimal rework required depending on the ATM being replaced, wall thickness and the local cardholder access legislation.

Customised collars or surrounds made by the owning organisation may need rework or replacement due to the following installation requirements.

Installation Categories 1

The physical installation of the 5886 Drive-Up is divided into three different categories.

1 An installation where a 5886 Drive-Up replaces a 5088. The hole in the wall must be modified and the plinth must be replaced with a new one to position the 5886 Drive-Up keyboard at the optimum height. See page 1-30.

2 An installation where a 5886 Drive-Up replaces a 5688 and where no modification has been made to the hole in the wall. The existing plinth must be replaced with a new one to position the 5886 Drive-Up keyboard at the optimum height. See page 1-32.

Note: The location of the cable access hole in the base of the ATM will change. Refer to the section “Requirements For The Floor” for more details.

3 A new installation of a 5886 Drive-Up at the optimum height. page 1-34.

For cases 1 and 2, an infill panel is required to accommodate the larger hole used by the previous 5088 or 5688 installation.

Installing Through a Glass Wall 1

If you are installing your ATM through a glass wall you may require a suitable glass support (normally a steel collar) to sit between the ATM collar and the glass - the requirement for this should be determined by the architect. If required, any such support should be sourced locally.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-29

Page 50: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsReplacing 5088 With Modifications to Hole in Wall

Replacing 5088 With Modifications to Hole in Wall 1

It is the responsibility of the owning institute to ensure that the heights from the road level to the facia items comply with any local regulations.

Note 1: A standard or advert collar is required at installation.

Note 2: The existing plinth must be replaced with a new one.

Note 3: An infill panel is required. For information on the infill panel, refer to the section “Infill Panel Dimensions” later in this chapter. For information on installing the infill panel, refer to chapter 8.

Dimensions for an ATM With Standard Sleeve 1

The standard sleeve 5886 Drive-Up can be installed through a wall that is up to 287 mm (11.30 in.) thick.

152.0 mm(5.98 in.)

Curb Set-back

930.0 mm(36.61 in.)

287.0 mm(11.30 in.)

Maximum WallThickness

Optimum Heightof No.5 Key

792.3 mm(31.19 in.)

Plinth

Remove Wall Section

618.0 mm(24.33 in.)

View from Inside Building

52.5 mm

(2.07 in.)

643.0 mm(25.31 in.)

ATM Base

Hole in Wall

1-30 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 51: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsReplacing 5088 With Modifications to Hole in Wall

Dimensions for an ATM With Short Sleeve 1

The short sleeve 5886 Drive-Up can be installed through a wall that is up to 165 mm (6.50 in.) thick.

Plinth Requirements 1

Refer to page 1-37 for plinth requirements.

152.0 mm(5.98 in.)

Curb Set-back

618.0 mm(24.33 in.)

View from Inside Building

930.0 mm(36.61 in.)

165.0 mm(6.50 in.)

Maximum WallThickness

52.5 mm

(2.07 in.)792.3 mm(31.19 in.)

Plinth

Remove Wall Section

Road Level

643.0 mm(25.31 in.)

Optimum Heightof No.5 Key

ATM Base

Hole in Wall

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-31

Page 52: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsReplacing 5688 With no Modifications to the Hole in Wall

Replacing 5688 With no Modifications to the Hole in Wall 1

It is the responsibility of the owning institute to ensure that the heights from the road level to the facia items comply with any local regulations.

Note 1: A standard or advert collar is required at installation.

Note 2: The existing plinth must be replaced with a new one.

Note 3: An infill panel is required. For information on the infill panel, refer to the section “Infill Panel Dimensions” later in this chapter. For information on installing the infill panel, refer to chapter 8

Dimensions for an ATM With Standard Sleeve 1

The standard sleeve 5886 Drive-Up can be installed through a wall that is up to 287 mm (11.30 in.) thick.

152.0 mm(5.98 in.)

Curb Set-back

930.0 mm(36.61 in.)

Optimum Heightof No.5 Key

825.0 mm(32.48 in.)

Plinth

287.0 mm(11.30 in.)

Maximum WallThickness

724.0 mm(28.50 in.)

View from Inside Building

52.5 mm

(2.07 in.)

624.0 mm(24.57 in.)

ATM Base

Hole in Wall

Road Level

1-32 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 53: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsReplacing 5688 With no Modifications to the Hole in Wall

Dimensions for an ATM With Short Sleeve 1

The short sleeve 5886 Drive-Up can be installed through a wall that is up to 165 mm (6.50 in.) thick.

Plinth Requirements 1

Refer to page 1-37 for plinth requirements.

152.0 mm(5.98 in.)

Curb Set-back

724.0 mm(28.50 in.)

View from Inside Building

930.0 mm(36.61 in.)

165.0 mm(6.50 in.)

Maximum WallThickness

52.5 mm

(2.07 in.)825.0 mm(32.48 in.)

Plinth

624.0 mm(24.57 in.)

ATM Base

Hole in WallOptimum Heightof No.5 Key

Road Level

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-33

Page 54: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstalling Through a New Hole

Installing Through a New Hole 1

It is the responsibility of the owning institute to ensure that the heights from the road level to the facia items comply with any local regulations.

Note: A standard or advert collar is required at installation.

Dimensions for an ATM With Standard Sleeve 1

The standard sleeve 5886 Drive-Up can be installed through a wall that is up to 287 mm (11.30 in.) thick.

152.0 mm(5.98 in.)

Curb Set-back

930.0 mm(36.61 in.)

OptimumHeightof No.5 Key

833.0 mm(32.80 in.)

Plinth

287.0 mm(11.30 in.)

Maximum WallThickness

610.0 mm(24.02 in.)

View from Inside Building

52.5 mm

(2.07 in.)

602.0 mm(23.70 in.)

ATM Base

Hole in Wall

Road Level

1-34 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 55: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInstalling Through a New Hole

Dimensions for an ATM With Short Sleeve 1

The short sleeve 5886 Drive-Up can be installed through a wall that is up to 165 mm (6.50 in.) thick.

Plinth Requirements 1

Refer to page 1-37 for plinth requirements.

152.0 mm(5.98 in.)

Curb Set-back

610.0 mm(24.02 in.)

View from Inside Building

930.0 mm(36.61 in.)

165.0 mm(6.50 in.)

Maximum WallThickness

52.5 mm

(2.07 in.)833.0 mm(32.80 in.)

Plinth

602.0 mm(23.70 in.)

ATM Base

Hole in WallOptimum Heightof No.5 Key

Road Level

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-35

Page 56: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsSealing the Hole in the Wall Against Cold and Water

Sealing the Hole in the Wall Against Cold and Water 1

To ensure that the temperature around the ATM is maintained during cold weather, it is important that the wall opening is prepared correctly. Any cavity in the wall should not extend into the wall opening, but sealed to provide a flush surface. The gap between the ATM sleeve and the wall opening should be left clear to allow air at room temperature to circulate.

To enable a good weather seal to be made between the wall and the ATM facia, a 25 mm (1 in.) wide smooth surface is required around the periphery of the wall opening.

Seal any cavity

Do not block air gaps

1-36 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 57: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsRequirements for the Floor

Requirements for the Floor 1

Support Plinth 1

The following illustrations show a plan of the base of the ATM (viewed from above) and its relationship with the exterior wall. If a plinth is used it must be no smaller than the base of the ATM and it must be constructed of a material, and in such a way, that it is capable of supporting the weight of the ATM (page 1-42).

Definition: A “plinth” is a platform on to which the ATM is bolted. This plinth enables the ATM to be installed at the required height through the wall.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-37

Page 58: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsRequirements for the Floor

Standard Sleeve Installation 1

Note 1: When an infill panel is required, this dimension is 461.0 mm (18.15 in.). For information on the infill panel, refer to the section “Infill Panel Dimensions” later in this chapter. For information on installing the infill panel, refer to chapter 8.

Note 2: The boundary, marked with a ‘C’, shows the cable access hole for all cables.

Note 3: The dotted boundary, marked with a ‘D’, shows where the cable access hole would be on a 5688 being replaced with 5886 Drive-Up.

800.0 mm

(31.5 in.)

287.0 mm(11.30 in.)Max. WallThickness

Hole in WallFront of Wall

150.0 mm

(5.91 in.)

500.0 mm

(19.69 in.)

473.0 mm

(18.62 in.)

See note 1

150.0 mm

(5.91 in.)

56.0 mm

(2.21 in.)

25.0 mm

(0.98 in.)

56.0 mm

(2.21 in.)

105.0 mm

(4.13 in.)

302.5 mm

(11.91 in.)

A

ACD

A

A

157.5 mm

(6.20 in.)500.0 mm

(19.69 in.)

815.0 mm

(32.09 in.)

Detail of hole A

30.0 mm(1.18 in.)

15.0 mm(0.59 in.)

25.0 mm(0.98 in.)

1-38 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 59: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsRequirements for the Floor

Short Sleeve Installation 1

Note 1: When an infill panel is required, this dimension is 347.0 mm (13.66 in.). For information on the infill panel, refer to the section “Infill Panel Dimensions” later in this chapter. For information on installing the infill panel, refer to chapter 8.

Note 2: The boundary, marked with a ‘C’, shows the cable access hole for all cables.

Note 3: The dotted boundary, marked with a ‘D’, shows where the cable access hole would be on a 5688 being replaced with 5886 Drive-Up.

800.0 mm

(31.5 in.)

165.0 mm(6.50 in.)Max. WallThickness

Hole in Wall

Front of Wall

150.0 mm

(5.91 in.)

500.0 mm

(19.69 in.)

359.0 mm

(14.13 in.)

See note 1

150.0 mm

(5.91 in.)

56.0 mm

(2.21 in.)

25.0 mm

(0.98 in.)

56.0 mm

(2.21 in.)

105.0 mm

(4.13 in.)

302.5 mm

(11.91 in.)

A

ACD

A

A

157.5 mm

(6.20 in.)500.0 mm

(19.69 in.)

815.0 mm

(32.09 in.)

Detail of hole A

30.0 mm(1.18 in.)

15.0 mm(0.59 in.)

25.0 mm(0.98 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-39

Page 60: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsMandatory Modifications to Plinth or Floor

Mandatory Modifications to Plinth or Floor 1

The following modifications must be made to the plinth:

Concrete Plinth 1

If a concrete plinth is used at installation, a section of the plinth should be cut-out to allow the cables which enter the base of the ATM to be fitted.

The following illustration shows the size of cut-out required for all security enclosure options.

Adjustable Plinth 1

If an adjustable plinth is used, holes should be drilled through the plinth, to allow the cables which enter the base of the ATM to be fitted.

ATM Installed Directly on to the Floor 1

If the ATM is installed directly on to the floor, without a plinth, the cabling must be routed through a channel in the floor. The channel must be large enough to allow the cabling to be routed along the floor and under the ATM.

Note: If a channel needs to be cut through the floor, this area must be large enough to allow the cabling to be routed along the floor and under the ATM.

1-40 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 61: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsMandatory Modifications to Plinth or Floor

800.0 mm

(31.5 in.)

Hole in Wall

81.0 mm

(3.19 in.)

76.5 mm

(3.01 in.)

11.0 mm

(0.43 in.)

815.0 mm

(32.09 in.)

161.0 mm

(6.34 in.)

50.8 mm

(2.00 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-41

Page 62: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsMandatory Modifications to Plinth or Floor

Floor Loading 1

The ATM must be installed on a floor capable of supporting the maximum weight. Only the maximum weight should be considered as additional options may be added after installation.

Standard Security enclosure:

● Maximum weight: 835kg (1841.2 lb.)● Floor loading: 1280.7 kg/m2 (262.3 lb./ft2).

Security Bolts 1

The ATM should be bolted to the floor, through the ‘A’ holes, see page 1-28, using four bolts with anchor washers. If the ATM is to be bolted down, the floor or plinth must be capable of withstanding the loading imposed by the anchor points for the bolts. The bolts and anchors must be supplied by the owning organisation.

The following is the minimum specification for bolts to secure the ATM to a plinth or a stone/concrete floor, through the ‘A’ holes:

16 mm (0.63 in.) diameter x 100 mm (3.94 in.) minimum length.

Floor Covering 1

An antistatic floor covering should be used and must be of a type that will not generate dust or fluff.

1-42 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 63: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInfill Panel Dimensions

Infill Panel Dimensions 1

Customised infill panels, made by owning organisations, should use the following dimensions as a guide:

Infill Panel (5088) 1

For a 5088 infill panel, use the following dimensions:

620.0 mm(24.41 in.)

70.0 mm(2.76 in.)

12.0 mm(0.47 in.)

90.0 mm(3.54 in.)

600.0 mm(23.62 in.)

800.0 mm(31.50 in.)

995.0 mm(39.17 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-43

Page 64: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInfill Panel Dimensions

Infill Panel (5688) 1

For a 5688 infill panel, use the following dimensions:

70.0 mm(2.76 in.)

12.0 mm(0.47 in.)

150.0 mm(5.91 in.)

920.0 mm(36.22 in.)

995.0 mm(39.17 in.)

600.0 mm(23.62 in.)

620.0 mm(24.41 in.)

1-44 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 65: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInternal Space Constraint for Fitting a Third Party Video Camera

Internal Space Constraint for Fitting a Third Party Video Camera 1

If a third party video camera is to be installed, there is a space constraint to consider. The location of the video camera is directly behind the camera window. The following dimensions should be calculated from the centre point on the window, as shown below.

Note 1: The depth constraint, from the rear of the camera window, is 220 mm (8.66 in.).

18.0 mm(0.71 in.)

36.0 mm(1.42 in.)

44.0 mm(1.73 in.)

44.0 mm(1.73 in.)

Camera Window

Camera Position

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-45

Page 66: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Physical RequirementsInternal Space Constraint for Fitting a Third Party Video Camera

1-46 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 67: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsElectrical Requirements

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Chapter 2

Electrical Requirements

Power Quality Distribution and Grounding Requirements 2-1AC Power Requirements 2-1Input Voltage Setting 2-1Power Consumption 2-1

Idle Mode 2-1Under Transaction 2-2

Power Cable 2-2Grounding Requirements 2-2Transient Power Loss 2-3EMI Susceptibility 2-3EMI Emission 2-3

Communications Requirements 2-4High Order Communications Cable 2-4

High Order Communications Standard Cable (RS-232) 2-5Remote Device Cables 2-6

RS-232 Cable 2-6Remote Status Monitor 2-9Alarm Interface Cable 2-11Remote Relay Cable 2-14

Page 68: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsElectrical Requirements

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 69: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2

-1

Power Quality Distribution and Grounding RequirementsElectrical Requirements2

Power Quality Distribution and Grounding Requirements 2

Voltage transients, line noise, surges, sags, impulses, and spikes may be experienced routinely or sporadically. When such phenomena occur, the use of protective devices, as described in Attachments A, may be required to ensure proper operation of the equipment.

AC Power Requirements 2

The maximum current requirements at the following input voltages are:

● 5.05A at 120V, or 9.10A with severe environment● 2.01A at 240V, or 4.2A with severe environment.

The maximum inrush current at the following input voltages are:

● 200A peak at 136V● 150A peak at 257V.

Note: If you are considering upgrading your ATM to include the cash acceptor, you should be aware that in the event of a power failure, there is the potential for customers cash to be retained in this module, and for details of the transaction to be lost. For this reason NCR do not recommend running a 5886 Drive-Up with a cash acceptor without an Uninterruptible Power Supply (UPS).

Input Voltage Setting 2

The ATM can operate from the following input mains voltages:

● 90V to 136V at 50/60Hz● 180V to 264V at 50/60Hz.

Power Consumption 2

A power consumption rate for your ATM can be calculated from the following information:

Idle Mode 2

● 307 Watts at 120V● 177 Watts at 240V.

Note: Power consumption is dependent on the configuration of your ATM.

Page 70: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsPower Quality Distribution and Grounding Requirements

Under Transaction 2

● 606 Watts at 120V, or 1092 Watts with severe environment● 482 Watts at 240V, or 1008 Watts with severe environment.

Note: Power consumption is dependent on the transaction rate of your ATM.

Power Cable 2

The ATM is supplied either as a 120V or a 220-240V unit. 120V ATMs are supplied with a power cable fitted with a NEMA type 5-15P power source connector. 220-240V ATMs are supplied with an unterminated power cable. Information about suitable power connectors is supplied with the accessories. Power connectors must be wired as shown below.

The power cable supplied is 3 metres (9 ft. 9.00 in.) in length. If it is necessary to increase this length to meet site requirements, then the extension must satisfy local or country regulations.

Note 1: If the ATM being installed is replacing a 5088 installation, it may be necessary to either lengthen the cable or re-position the electrical sockets, as the cable access hole is in the security enclosure and toward the rear of the enclosure.

Note 2: If the ATM being installed is replacing a 5688 installation, it may be necessary to either lengthen the cable or re-position the electrical sockets, as the cable access hole is on the other side.

Warning This equipment must be earthed.

Note: The annotations within brackets are included to comply with United Kingdom legislation and refer to the markings on United Kingdom three pin plugs.

Grounding Requirements 2

The ATM operates from a single phase, 3 wire supply; live, neutral and ground. The power requirements of this unit will normally permit it to operate within existing wiring configurations and from existing branch mains outlets providing:

1 Where this supply is provided from a general purpose distribution panel, then the other branch circuits from this panel must not be used to support heavy inductive loads such as air

2-2 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 71: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsPower Quality Distribution and Grounding Requirements

conditioners, elevators, microwave ovens, and so on. Nor may such equipment be operated on the same branch circuit as the ATM.

2 If using distribution panels, all branch circuit grounding conductors must be connected to an insulated ATM strip in the distribution panel. The grounding conductor from the distribution panel to the building ground point must be at least equal in size to the power conductor necessary to supply the NCR system.

Note: The building ground point can affect data integrity. For additional information refer to the ‘Data Line Transient Protection’ section of Attachment A.

Transient Power Loss 2

The voltage loss due to power interruptions must not be more than 50% of the nominal value for a maximum of one half cycle at a maximum rate of 1 every 10 seconds.

EMI Susceptibility 2

The ATM meets EN 55024 (1998) “ITE Immunity Standard”.

EMI Emission 2

The ATM meets FCC CFR 47 Prt 15 Class A and EN 55022 (1998) Class A requirements for radiated and conducted emission.

The ATM meets EN61000-3-2 (latest revision) Mains Harmonics (Class A) and EN61000-3-3 (latest revision) Mains Flicker requirements for conducted emission.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2-3

Page 72: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

Communications Requirements 2

Voltage transients, line noise, surges, sags, impulses, and spikes may be experienced routinely or sporadically. When such phenomena occur, the use of protective devices, as described in Attachment A, may be required to ensure proper operation of the equipment.

It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with NCR specifications and requirements and with all national, state or local telephone and telegraph regulations and laws.

High Order Communications Cable 2

The high order communications cable type depends upon the communications system to be used. The following cable may be required.

Note: Communications cables are not supplied with the ATM. If these cables are required, it is the customer’s responsibility to have them installed. The specification for this cable is supplied in the following section. When producing cables allow for 1.8 metres (6 feet) of cable within the ATM.

2-4 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 73: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

High Order Communications Standard Cable (RS-232) 2

The standard high order communications system supports most common bit and byte oriented disciplines (synchronous and asynchronous) with an RS-232 interface.

The interconnecting cable to the remote modem should not exceed 15.24 metres (50 feet) in length, and must conform to the specification and wiring given on the following diagram.

1, 2 6 5

CHASSIS GND1

TD.V2

RD.V3

RQS.V

TSET.V

4

15

RFS.V

RSET.V

5

17

DSR.V

WCA.V

6

18

SIG.GND

DTR.V

EXT SET.V

7

20

24

RLSD.V

CI.V

WIN.V

8

22

25

1. Connector, 25 way (NCR part no. 006-0005897).2. Terminal wire, male (NCR part no. 009-0002642).3. Cable, multiconductor (NCR part no. 007-8907033).4. Connector (determined by remote device).5. Shell hood (NCR part no. 006-1500038).6. Screw retainer (NCR part no. 601-0101584).

3 4

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2-5

Page 74: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

At a point 550mm (21.65 in.) from the connector end of the cable, remove a 20mm (0.79in.) section of the outer sleeve as shown. At a further 660mm (25.98 in.), remove another 20mm (0.79 in.) section of the outer sleeve.

Note: Take care not to cut through the cable shielding when removing the outer sleeve.

Remote Device Cables 2

The specifications for these cables are supplied below.

RS-232 Cable 2

The ATM can have up to two RS-232 outlets which can be configured to provide an interface for one of two options:

● Remote camera● Remote card access device.

20.0 mm

(0.79 in.)20.0 mm

(0.79 in.)

550.0 mm

(21.65 in.)660.0 mm

(25.98 in.)

2-6 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 75: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

For both options the cable is limited in length to 15.24 metres (50 feet) and must conform to the specification and wiring given here.

Note: The modemless cable adapter is supplied with RS-232 interface feature kits. This adapter performs crossover and linking normally associated with modemless operation. If this linking is not required, the modemless cable adapter may be removed and the RS-232 Interface Cable connected directly to the ATM.

1. Connector, 25 way (NCR part no. 006-0005897).2. Terminal wire, male (NCR part no. 009-0002642).3. Cable, multiconductor (NCR part no. 007-8907033).4. Connector (determined by remote device).5. Shell Hood (NCR part no. 006- ).6. Screw retainer (NCR part no. 601-0101584).

1500038

CHASSIS GND CHASSIS GNDTDRDRSLDCTS

DSRDTRSIGNAL GND

RTS

Modemless Cable Adapter RS232 Interface Cable

TDRDRTSCTSRSLDDSRDTRSIGNAL

1 112 223 338 845 554 486 66

20 20207 77

1, 2 6 5 3 4

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2-7

Page 76: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

At a point 300mm (11.81 in.) from the connector end of the cable, remove a 20mm (0.79in.) section of the outer sleeve as shown. At a further 660mm (25.98 in.), remove another 20mm (0.79 in.) section of the outer sleeve.

Note: Take care not to cut through the cable shielding when removing the outer sleeve.

20.0 mm

(0.79 in.)20.0 mm

(0.79 in.)

300.0 mm

(11.81 in.)660.0 mm

(25.98 in.)

2-8 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 77: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

Remote Status Monitor 2

The remote status monitor feature is supplied as a complete assembly and consists of a status indicator unit, 76.2 metres (250 feet) of cable and a connector.

At a point 380mm (14.96 in.) from the connector end of the cable, remove a 20mm (0.79in.) section of the outer sleeve as shown. At a further 660mm (25.98 in.), remove another 20mm (0.79 in.) section of the outer sleeve.

Note: Take care not to cut through the cable shielding when removing the outer sleeve.

If you are required to shorten the cable, proceed as follows:

1 Remove the cover from the remote status indicator unit.

20.0 mm

(0.79 in.)20.0 mm

(0.79 in.)

380.0 mm

(14.96 in.)660.0 mm

(25.98 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2-9

Page 78: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

2 Disconnect the four leads from the indicator, that is E1, E2, E3 and E4.

3 Cut the cable to the required length and strip the four wire ends.

4 Connect the wires to the correct terminals.

5 Replace the status indicator cover.

Red

(Green) E1

(Red) E2

(White) E3

(Black) E4

Yellow

Green

2-10 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 79: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

Alarm Interface Cable 2

The ATM may optionally be configured to provide an alarm interface which enables the ATM to be connected to an external local alarm system. The interface may take the form of one of two options; a basic alarm system or an enhanced alarm system.

The external alarm system must provide to the ATM, through the alarm interface cable wiring, a non interruptible, stabilised power supply with the following specifications:

● 12V +- 2V dc● 200mA maximum● Ripple, 5% maximum.

The interconnecting cable to the ATM is similar for both alarm interface options and must conform to the following specification and wiring:

1. Connector, 25 Way (NCR part no. 006-0005896)2. Terminal, wire, female (NCR part no. 009-0002640)3. Cable, multiconductor (determined by the alarm installed).4. Connector (determined by remote device).5. Shell Hood (NCR part no. 006- ).6. Screw retainer (NCR part no. 601-0101584).

1500038

1,2 5 3 46

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2-11

Page 80: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

At a point 300mm (11.81 in.) from the connector end of the cable, remove a 20mm (0.79in.) section of the outer sleeve as shown. At a further 660mm (25.98 in.), remove another 20mm (0.79 in.) section of the outer sleeve.

Note: Take care not to cut through the cable shielding when removing the outer sleeve

Basic Alarm Interface Cable Wiring

20.0 mm

(0.79 in.)20.0 mm

(0.79 in.)

300.0 mm

(11.81 in.)660.0 mm

(25.98 in.)

CHASSIS GND

SILENT ALARM N.O. *

DOOR ALARM N.C..

VIBRATION/HEAT N.O.

SILENT ALARM COMMON *

SILENT ALARM N.C. *

VIBRATION/HEAT COMMON

VIBRATION/HEAT N.C.

DOOR ALARM N.O.

DOOR ALARM COMMON

+12V

+12V RETURN

1

9

21

7

19

10

22

8

20

12

23

25* Optional

2-12 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 81: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

Enhanced and High Security Alarm Interface Cable Wiring

CHASSIS GND

DOOR ALARM N.O.

TAMPER ALARM N.C..

TEST TRANSMITTER A

SILENT ALARM COMMON *

TAMPER ALARM N.O.

+12V

1

6

12

21

3

9

7

16

22

5

10

20

8

18

23

19

25

TEST TRANSMITTER B

DOOR ALARM N.C.

TAMPER ALARM COMMON

DOOR ALARM COMMON

.

SILENT ALARM N.O. *

COMPOSITE ATTACK N.C.

COMPOSITE ATTACK N.O.

SILENT ALARM N.C. *

+12V RETURN

* Optional

COMPOSITE ATTACK COMMON

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2-13

Page 82: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Electrical RequirementsCommunications Requirements

Remote Relay Cable 2

The remote relay provides a pair of open contacts, rated at 28 volts per ampere for both ac and dc supplies, which can be closed to activate a remote device. The interconnecting cable to a remote device must conform to the following specification and wiring:

At a point 380mm (14.96 in.) from the connector end of the cable, remove a 20mm (0.79in.) section of the outer sleeve as shown. At a further 660mm (25.98 in.), remove another 20mm (0.79 in.) section of the outer sleeve.

Note: Take care not to cut through the cable shielding when removing the outer sleeve.

1, 2

1. Connector, 2 way Mate-N-Lock (NCR part no. 007-9814285).2. Terminal wire, male (NCR part no. 007-2009663).3. Cable, multiconductor (NCR part no. 006-5800006).4. Connector (determined by remote device).

3

1RL1

2RL2

4

20.0 mm

(0.79 in.)20.0 mm

(0.79 in.)

380.0 mm

(14.96 in.)660.0 mm

(25.98 in.)

2-14 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation

Page 83: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsEnvironmental Requirements

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Chapter 3

Environmental Requirements

Environmental Requirements 3-1Temperature and Humidity 3-1Barometric Pressure 3-2Electromagnetic Compatibility (EMC) and Safety 3-4

EMC Directives 3-4Immunity Standards 3-4

Acoustics 3-4Heat Dissipation 3-4Air Flow 3-4Temperature Rise 3-4

Page 84: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsEnvironmental Requirements

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 85: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 3

-1

Environmental RequirementsEnvironmental Requirements3

Environmental Requirements 3

For the ATM to function correctly the site at which it is to be installed should meet the following environmental requirements.

Temperature and Humidity 3

The ATM will operate over a range of temperature and humidity. However, continuous operating at or near the range limits or in a location where the temperature and humidity change beyond the specification, should be avoided. The temperature and humidity ranges are as follows:

Normal operating range (interior to wall environment):

● Temperature: 10oC to 40oC (50oF to 104oF) ● Temperature change rate: 10oC/hour (18oF/hour) ● Relative humidity: 20% to 80% ● Relative humidity change rate: 10%/hour ● Dew point temperature restriction: 26oC (79oF) maximum.

Note: The humidity inside the building is restricted to a maximum of 30% at an outside temperature of -35oC (-31oF) with a linear (straight line) relationship between temperature and humidity to a maximum humidity of 80%.

Normal operating range (exterior to wall environment):

● Temperature: -35oC to 50oC (-31oF to 122oF) ● Temperature change rate: 10oC/hour (18oF/hour) ● Relative humidity: 10% to 100% ● Relative humidity change rate: 10%/hour.

Page 86: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Environmental RequirementsEnvironmental Requirements

Storage range (up to three months):

● Temperature: -10oC to 50oC (14oF to 122oF) ● Temperature change rate: 15oC/hour (27oF/hour) ● Relative humidity: 10% to 90%

Transit range (up to one week):

● Temperature: -40oC to 60oC (-40oF to 140oF) ● Temperature change rate: 20oC/hour (36oF/hour) ● Relative humidity: 5% to 95%

Extreme power on range (up to one hour):

● Temperature: 0oC to 40oC (32oF to 104oF) ● Temperature change rate: 10oC/hour (18oF/hour) ● Relative humidity: 10% to 95%.

Barometric Pressure 3

Barometric pressure details are as follows:

● Operating and transit limits: 105kPa (15.2 lb. F/in.) ● Equivalent altitude: up to a maximum of

3000 metres (9842 feet).

The ATM will accommodate an external to internal pressure difference of up to 70 pascal (with the severe environment option fitted).

How to determine whether the severe environment option is required

The following equipment is required:

● a gauge which measures pressure with an appropriate scale (up to 100 pascals)

● a piece of tubing to fit the gauge● silicon sealant● suitable wall sealant.

3-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 87: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Environmental RequirementsEnvironmental Requirements

The following procedure should be followed, before the hole in the wall is created:

1 Drill a hole through the exterior wall where the ATM’s facia is to be located. The diameter of the hole should be correct to accommodate the diameter of the tubing being used.

2 Insert the tubing through the hole so that the tube is located inside the building.

3 Use the sealant to make sure that there are no gaps between the tubing and the exterior wall.

4 Attach the gauge to the loose end of the tube (that is, on the inside of the building).

5 Take a note of the pressure reading.

6 Remove the tube and gauge and seal the hole in the wall using a suitable sealant.

7 If the pressure gauge indicates a negative pressure differential, then NCR recommend that the ATM to be installed should have severe environment fitted.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 3-3

Page 88: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Environmental RequirementsEnvironmental Requirements

Electromagnetic Compatibility (EMC) and Safety 3

The ATM complies with the following standards and directives:

EMC Directives 3

● 89/336/EEC “EMC Directive”● 92/31/EEC “Amending EMC Directive”● 73/23/EEC “Low Voltage Directive”● 93/68/EEC “CE Marking Directive”.

The Harmonised EMC Standards are as follows:

● Radiated and Conducted:● EN 55022 (1998) Class A● FCC CFR 47 Part 15 Class A.

● Conducted (220V - 240V units):● EN61000-3-2 (latest revision) Mains Harmonics (Class A)● EN61000-3-3 (latest revision) Mains Flicker.

Immunity Standards 3

● EN 55024 (1998) “ITE Immunity Standard”.

The Harmonised Safety Standard is as follows:

● EN 60950 “Safety of IT Equipment”.

Acoustics 3

Sound Power

● 65 dB(A) idle● 68 dB(A) operating.

Heat Dissipation 3

The heat dissipation of the ATM is 1580kJ/hour (1500 BTU/hour) maximum.

Air Flow 3

The air flow through the ATM is rated at 0.1 m3/s (212 ft3/min.).

Temperature Rise 3

The temperature rise for air passing through the ATM is 3oC (5.4oF).

3-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 89: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsDecal Requirements

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Chapter 4

Decal Requirements

Decal Dimensions 4-1Card Orientation Window 4-2Card Acceptance Decal 4-3Clear Window 4-3Advert Light 4-4Entry/Exit Slot Decals 4-5

Page 90: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsDecal Requirements

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 91: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 4

-1

Decal DimensionsDecal Requirements4

Decal Dimensions 4

The following illustrations provide the specifications and locations for the decals which you may wish to fit to the front of your ATM.

Statement Exit

Cash Deposit

Cash Exit/Deposit Entry/Cheque Entry

Advert Light

Receipt Exit

Card Reader(Motorised/Dip)

Cash Exit/Deposit EntryCash Deposit

Page 92: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Decal RequirementsDecal Dimensions

Card Orientation Window 4

If the window next to the Card Reader entry/exit slot is to be customised to indicate card orientation, the card/decal to be inserted into the window should be of the following dimensions.

The insert should be a maximum of 0.75 mm (0.029 in.) thick.

The decal should not be made of absorbent material if the front of the ATM is likely to be subjected to rain.

54.0 mm(2.13 in.)

86.0 mm(3.39 in.)

3.0 mm (0.12 in.)radius on all corners

4-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 93: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Decal RequirementsDecal Dimensions

Card Acceptance Decal 4

If a decal is required to advertise which cards can be used in the ATM, it should be positioned on the side wall of the ATM facia. The decal can by any size, providing it fits onto this area.

Clear Window 4

If a deposit feature is not configured, then the front of the deposit blank moulding will have a large clear window. If an insert is to be made to go behind the window it should be of the following dimensions.

The insert should be a maximum of 0.8 mm (0.03 in.) thick. NCR recommend that the insert be made from one of the following materials:

● Polycarbonate● Polyester● Paper.

Note: Paper is not recommended if the front of the ATM is likely to be subjected to rain.

169.0 mm(6.65 in.)

55.0 mm(2.17 in.)

1.0 mm (0.04 in.)radius on all corners

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 4-3

Page 94: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Decal RequirementsDecal Dimensions

Advert Light 4

The following illustration shows dimensions for an advert light decal. These dimensions are based on a decal being applied to the flat inside area of the advert light panel.

575.0 mm(22.64 in.)

130.0 mm(5.12 in.)

4-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 95: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Decal RequirementsDecal Dimensions

Entry/Exit Slot Decals 4

The front of the ATM has recesses for decals to identify the entry and exit slots. The following are guidelines to the decal sizes. The decals should be a maximum of 0.5 mm thick and it is recommended that they be made from Textured Polycarbonate with 3M 467 High Performance MP adhesive.

Note: A combination of your application and screen graphics can be used as an alternative to indicate the cash/media exit slot.

50.0 mm(1.97 in.)

2.0 mm(0.08 in.)

R 4.0 mm(0.16 in.)

MEI Area of Decal to beTransparent to AllowLight to Pass Through

2.0 mm(0.08 in.)

118.0 mm(4.65 in.)

12.0 mm(0.47 in.)

2.0 mm(0.08 in.)

4.0 mm(0.16 in.)

59.0 mm(2.32 in.)

86.0 mm(3.39 in.)See Note

Decal dimensions for:STATEMENTRECEIPTCASHENVELOPECHEQUE

Decal dimensions forCARD

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 4-5

Page 96: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Decal RequirementsDecal Dimensions

4-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 97: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstallation Accessories and Planning Check List

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Chapter 5

Installation Accessories and Planning Check List

Installation Accessories 5-1

Planning Check List 5-2

Page 98: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstallation Accessories and Planning Check List

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 99: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 5

-1

Installation AccessoriesInstallation Accessories and Planning Check List5

Installation Accessories 5

When installing your ATM it is recommended that you have the following items available:

● Pincers/claw hammer to remove staples/nails from around the pallet

● Pozi drive screwdrivers (various sizes)● Small flat blade screwdriver● Hacksaw - only required to configure passbook printer● To fit fixing bolts:

● UL safe - 19 mm (3/4 in.) ring/open-ended combination spanner and socket

● CEN Grade III or CEN LGAI Security enclosure - 27 mm (1 1/8 in.) socket with a maximum outside diameter of 33 mm (1 5/16 in.)

● 7 mm (9/32 in.) ring/open-ended combination spanner or socket to fit the standard or advert facia light

● 10 mm (3/8 in.) ring/open-ended combination spanner for bolt heads

● 7 mm (9/32 in.) nut spinner for M4 nuts● Lifting/moving device. Lifting trolleys must have a maximum

toe plate length of 380 mm (14.96 in.) and a minimum toe plate width of 120 mm (4.72 in.)

● Cutter to cut cable ties● Packing to protect the exterior of the ATM while on a trolleys.

Page 100: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installation Accessories and Planning Check ListPlanning Check List

Planning Check List 5

To assist you in preparing your site for the arrival of your ATM we provide here a check list of the various procedures that you should carry-out prior to the arrival of your ATM. The procedures given are listed in chronological order, starting with the procedure that you should do first.

Activity

Select site and make scaled floor plan

Ensure correct environmental conditions

Establish all contractor and vendor related schedules

Check communication line requirements

Plan application development

Check floor plan and make any alterations

Install additional electrical outlets (if required)

Prepare site for data communication

Arrange for designing and printing of overlays/ decals

Order technical publications

Order media supplies

Plan operator training (optional)

Ensure data comms. equipment is installed and tested

Ensure installation accessories are available

5-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 101: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstallation Procedure

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Chapter 6

Installation Procedure

Introduction 6-1Installation Steps 6-1Site Preparation 6-1Tools Required For ATM Installation 6-1Moving the ATM 6-2

Page 102: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstallation Procedure

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 103: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 6

-1

IntroductionInstallation Procedure6

Introduction 6

Installation Steps 6

The installation of the NCR 5886 Drive-Up Automated Teller Machine (ATM) can be divided into several steps:

● Moving the ATM● Unpacking the ATM● Inspecting the ATM for damage● Removing the ATM from the pallet● Fitting the severe environment (if required)● Fitting the infill panel to the wall (if required)● Fitting the cheque receiving bin (if configured)● Positioning the ATM through the hole in the wall● Fitting the collar● Sealing to the outside wall● Bolting the ATM to floor or plinth● Removing the internal packaging ● Connecting cables to the ATM● Configuring the ATM● Applying decals to the facia.These steps are described in detail in the chapters that follow.

Site Preparation 6

Before installing your ATM make sure that the installation site conforms to the specifications given in Chapter 1 to Chapter 5 of this publication.

Tools Required For ATM Installation 6

To install the ATM you will require a number of tools. These are listed in Chapter 5.

Page 104: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installation ProcedureIntroduction

Moving the ATM 6

The ATM will be mounted on a pallet and contained in a cardboard crate.

Move the ATM to its installation site using lifting trolleys. To reduce the chance of damaging the ATM, and the premises, the ATM should be moved with its packaging intact.

Details of the ATM dimensions, packaging dimensions and clearances required for moving the ATM in a confined space can be found in Chapter 1.

6-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 105: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsPreparing the ATM For Installation

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Chapter 7

Preparing the ATM For Installation

Removing the External Packaging From the ATM 7-1Inspecting the ATM For Damage 7-1Installation Report Form 7-2

Opening the ATM 7-3How to Open the ATM 7-3

How to Unlock and Lock the Standard Security Enclosure 7-5Keylocks 7-6Combination Locks 7-6Combination Lock and Separate Keylock 7-8

Controlled Access Electronic Lock 7-12Controlled Access Electronic Lock (Type 1) 7-13Controlled Access Electronic Lock (Type 2) 7-15

Electronic Lock with Time Delay 7-21Unlocking 7-21Locking 7-22Emergency Opening Procedure 7-23

Removing the ATM From Its Pallet 7-24

Page 106: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsPreparing the ATM For Installation

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 107: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7

-1

Removing the External Packaging From the ATMPreparing the ATM For Installation7

Removing the External Packaging From the ATM 7

Before removing the external packaging, examine it for signs of damage which may have occurred during transit. Make a note of any external damage for inclusion in a damage report. See the next section for details on reporting damage.

When the ATM is approximately in its position for installation, remove the external packaging as follows:

1 Lever out the staples from around the base of the crate and then lift the crate from the pallet.

2 Remove the cardboard collar and plastic cover.

3 Remove any kit packages.

4 Remove all pieces of tape from the exterior of the ATM.

Inspecting the ATM For Damage 7

After unpacking the ATM, inspect it for any signs of damage.

If the ATM is damaged a report should be made in accordance with the following procedures:

● Customers in the USA should refer to the Branch Practices manual and report the damage on: ● Marketing communications document

No. 73-130, file location 2-20-57● Marketing communications document

No. 71-273, file location 2-70-40● Other customers should use one of the following procedures:

● Customers who are required to arrange their insurance locally should have the claim processed locally. A separate report of damage should be made to Inventory Return Control, Dayton

● Customers who have insurance arranged by NCR Insurance Department, Dayton, must report the damage on Form F-2100 (Notice of Damage) to NCR Insurance Department and send a copy to Inventory Return Control.

The addresses for NCR Insurance and Inventory Return Control are:

● Risk Management and Insurance, NCR Corporation, Dayton, Ohio 45479, USA.

● Inventory Return Control, International Field Engineering Support, NCR Corporation, Dayton, Ohio 45479, USA.

Page 108: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationRemoving the External Packaging From the ATM

Installation Report Form 7

The Installation Report Form delivered with the ATM should always be completed and returned. Make sure that you report any problems in the following areas:

● Malfunction of the ATM or any of its devices● Internal or external defects arising as a result of handling or

transit damage● Missing or damaged accessories. All the accessories are fitted at

the appropriate feature inside the ATM.

7-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 109: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationOpening the ATM

Opening the ATM 7

Before you open the ATM, remove the tape from the security enclosure door, handles, dials and top-box.

The key to open the top-box is shipped inside an envelope, which is taped to the ATM.

The key to open the security enclosure is taped to the base-plate of the 80-column printer.

How to Open the ATM 7

To open the ATM, proceed as follows:

1 Turn the top-box key clockwise.

Note: The key is shipped inside the document bag secured to the outside of the unit.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-3

Page 110: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationOpening the ATM

2 Open the top-box door upwards, until the gas struts are fully extended.

3 Unlock the security enclosure.

7-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 111: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock the Standard Security Enclosure

How to Unlock and Lock the Standard Security Enclosure 7

The standard security enclosure of your ATM will have a locking handle plus one lock (a primary lock), or two locks (a primary and a secondary lock). The possible lock types for primary and secondary locks are as follows:

● Primary lock types:● Keylock● Combination lock● Combination lock with silent alarm● Combination lock with keylock

● Secondary lock types:● Keylock● Combination lock● Combination lock with silent alarm● Combination lock with electronic override.

Note: The make of lock fitted (Standard or Sargent and Greenleaf) depends on the configuration of the ATM. The procedures for opening and closing the various types of lock are the same for both makes.

The following illustration shows the relative positions of primary and secondary locks.

0

90

80

70

6050

40

30

20

10

0

90

80

70

6050

40

30

20

10

Primary Lock

Secondary Lock

Locking Handle

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-5

Page 112: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock the Standard Security Enclosure

If you have a primary and a secondary lock fitted to your ATM they must be unlocked in the following order:

1 Unlock the secondary lock.

2 Unlock the primary lock.

3 Use the handle to retract the bolt and open the door.

The primary and secondary locks must be locked in the following sequence:

1 Close the door and use the handle to operate the bolt.

2 Lock the primary lock.

3 Lock the secondary lock.

Keylocks 7

The pair of keylock keys supplied with your ATM have been pre-cut to a random factory-set combination. If one key should get lost, then you should get a new pair of keys and then change the keylock setting.

How to Unlock a Keylock 7

To unlock a keylock, insert the key into the lock and turn it clockwise as far as it will turn.

How to Lock a Keylock 7

To lock a keylock, turn the key counterclockwise as far as it will turn and then remove the key.

Combination Locks 7

Three variants of combination lock may be fitted to your ATM:

● Basic combination lock ● Combination lock with integral keylock● Combination lock with a silent alarm option.

All the variants of the combination lock are three-number combination locks.

The locks are precision locks, therefore, extreme care must be taken to align combination numbers with the index.

Turn the dial slowly and steadily. If, after turning the dial the correct number of revolutions, any number is turned beyond the index, the entire series of combination numbers must be re-dialled.

Do not turn the dial back to regain a proper alignment of the number and index, because each time a selected number is aligned with the index a revolution is counted.

7-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 113: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock the Standard Security Enclosure

The procedures for unlocking and changing the combination on a combination lock are the same regardless of whether the lock is a primary or secondary lock.

Factory Setting 7

If the combination lock is set at the original factory setting of 50, you unlock it as follows, dialling on the opening index:

1 If a keylock is fitted to the combination lock, insert the key into the lock and turn it clockwise.

2 Turn the dial a minimum of four turns counterclockwise and stop on 50.

3 Turn the dial slowly clockwise until the bolt retracts. The lock is now open. Use the handle on the door to retract the door bolt and open the door.

Customer Setting Combination 7

If the combination has been set at a three-number combination, for example 36-82-44, unlock it as follows:

1 If a keylock is fitted to the combination lock, insert the key into the lock and turn it clockwise.

2 Turn the dial counterclockwise, passing the first number (36) three times, stop on the first number (36) the FOURTH time.

3 Turn the dial clockwise, passing the second number (82) twice, and stop on the second number (82) the THIRD time.

4 Turn the dial counterclockwise, passing the third number (44) once, and stop on the third number (44) the SECOND time.

0

90

80

70

6050

40

30

20

10

Changing Index

Opening Index

Dial

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-7

Page 114: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock the Standard Security Enclosure

5 Turn the dial clockwise until the bolt retracts. The lock is now open. Use the handle on the door to retract the door bolt and open the door.

How to Operate the Silent Alarm 7

The silent alarm is triggered, if fitted, by adding 10 to the first number of the combination. For example if the first number was 34, dial 44 to trigger the silent alarm. Dial the next two numbers of the combination as normal, the combination lock will open as normal but the alarm will have been triggered.

How to Lock the Combination Lock 7

To lock the combination lock, turn the dial at least four complete turns counterclockwise. If a keylock is fitted to the combination lock, turn the dial until 0 is in line with the opening index and then turn the key counterclockwise and remove it from the lock.

How to Change the Combination 7

Detailed instructions on how to change the combination of a lock are inside the security enclosure.

Combination Lock and Separate Keylock 7

Unlocking 7

On arrival at the site, the combination lock is set at the original factory setting of 50. To unlock the security enclosure, proceed as follows:

1 Turn the dial of the combination lock until 0 is under the index mark.

2 Turn the dial of the combination lock counter-clockwise until 50 is under the index mark for the FOURTH time.

Note: Combination locks are precision locks, therefore, extreme care must be taken to align combination numbers with the index. Turn the dial slowly and steadily. If any of the numbers in the combination is turned beyond the index, the entire series of numbers must be re-dialled.

Index Mark

7-8 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 115: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock the Standard Security Enclosure

3 Turn the dial clockwise until 0 is under the index mark or until it stops. The combination lock is now open.

4 Insert the key into the keylock and turn it clockwise to unlock the keylock.

5 Turn the locking handle clockwise through approximately 45o to retract the door bolt. The door is now unlocked.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-9

Page 116: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock the Standard Security Enclosure

Locking 7

To close and lock the security enclosure proceed as follows:

1 Close the door.

2 Turn the locking handle counterclockwise through approximately 45o to the vertical position to engage the door bolt.

3 Turn the key in the keylock counterclockwise and then remove the key.

4 Lock the combination lock by turning the dial at least four complete turns counterclockwise.

Customer Setting Combination 7

If the combination has been set at a three-number combination, for example 36-82-44, unlock it as follows:

1 If a keylock is fitted to the combination lock, insert the key into the lock and turn it clockwise.

2 Turn the dial counterclockwise, passing the first number (36) three times, stop on the first number (36) the FOURTH time.

3 Turn the dial clockwise, passing the second number (82) twice, and stop on the second number (82) the THIRD time.

4 Turn the dial counterclockwise, passing the third number (44) once, and stop on the third number (44) the SECOND time.

5 Turn the dial clockwise until it stops. The lock is now open. Use the handle on the door to retract the door bolt and open the door.

7-10 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 117: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock the Standard Security Enclosure

How to Lock the Combination Lock 7

To lock the combination lock, turn the dial at least four complete turns counterclockwise. Turn the dial until 0 is in line with the opening index and then turn the key counterclockwise and remove it from the lock.

How to Change the Combination 7

Detailed instructions on how to change the combination of a lock are inside the security enclosure.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-11

Page 118: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock an Electronic Lock

How to Unlock and Lock an Electronic Lock 7

Unlocking 7

To unlock the security enclosure proceed as follows:

1 With the keypad in its vertical position, enter the first six digits of the combination (set to 123456 when shipped from factory). If the sequence is entered correctly the lock will beep and the LED flash. If the lock has been set to operate on a single combination, proceed to step 3.

2 If the lock is set to operate on a dual combination, enter the second six digits of the combination (set to 456789 when shipped from factory). If the sequence is entered correctly, the lock will beep and the LED flash.

3 Turn the keypad clockwise to unlock the lock.

7-12 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 119: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock an Electronic Lock

4 Turn the keylock clockwise to unlock the lock.

5 Turn the safe handle counterclockwise to open the door.

Note: If when entering a combination you enter the wrong combination 4 times, a 5 minute time delay period is activated. During this time the LED on the lock will flash red at 10 second intervals. You must wait until the end of the 5 minute period before attempting to enter the correct combination.

Note: If fitted, the silent alarm may be activated by entering one number higher or lower for the last digit of a combination. For example, if the combination was 1-2-3-4-5-6, entering 1-2-3-4-5-5 or 1-2-3-4-5-7 would activate the silent alarm.

Note: Repeated beeping of the lock during an opening sequence indicates that the lock battery requires to be replaced. If the lock keypad is completely “dead”, that is, it makes no sound or flashes, follow the emergency opening procedure to open the lock prior to having the battery replaced.

Locking 7

To lock the security enclosure proceed as follows:

1 Close the security enclosure door and turn the handle clockwise.

2 Turn the keylock counterclockwise

3 Turn the keypad counterclockwise until the keypad is vertical. The door should now be locked.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-13

Page 120: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock an Electronic Lock

Emergency Opening Procedure 7

If the keypad is completely “dead”, that is it does not flash or beep, it is an indication that the lock battery requires to be replacing. To open the lock when it is in this condition you must hold a new 9 volt alkaline battery against the terminals of the lock. The larger battery terminal must be against the larger of the lock terminals. The battery must be held in place while carrying out the normal procedures for opening the lock.

7-14 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 121: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock a Controlled Access Electronic Lock

How to Unlock and Lock a Controlled Access Electronic Lock 7

Note: For ATMs with security enclosures fitted with a Kaba Mas (Mas-Hamilton) controlled access electronic lock, refer to the following Kaba Mas Group publications for details of how to set up and manage the operations of the lock:

● CENCON System 2000 Access Control System● Getting Started Guide● Supervisor Guide● Special Supervisor Guide● FLM Dispatcher Guide● Route Dispatcher Guide● CENCON 2000 System Guide.These publications can be purchased from the following Order Point:

Kaba Mas Corporation749, W. Short StreetLEXINGTONKentucky40508Tel: (1) (1) 859 253-4744Toll Free (USA Only) 888 959-4715Fax: (1) 859-225-2655

Note: For the attention of Customer Service Manager.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-15

Page 122: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock a Controlled Access Electronic Lock

Your ATM may be configured with a controlled access electronic lock Type 1 or Type 2. The following diagram distinguishes between the two types.

Controlled Access Electronic Lock (Type 1) 7

Unlocking 7

To unlock a security enclosure with a controlled access electronic (type 1) in Bank Mode (1 User), proceed as follows:

1 Spin the knob on the lock.

Note: Rotating the knob generates enough power within the lock to allow it to operate for 90 seconds after the rotation stops. The LCD powers down after 40 seconds. Upon power up, the LCD will provide instructions for the user to follow while opening the enclosure.

2 34

5

1

* 6

#

78 9

0Type 1

Type 2

Cencon Lock

Locking Handle

Keypad

LCD

Touch KeyReader

Knob(Opening/Closing)

7-16 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 123: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock a Controlled Access Electronic Lock

2 Keep spinning the knob until "EC" appears on the LCD and beeps are heard.

3 Enter personal combination number (or the factory default number (50-25-50) using the keypad.

4 "IPI" (Input Personal Identifier) will appear on the LCD.

5 Touch the personal identification key to the key reader.

Note: The lock processor will generate a combination number and compare the user entered combination number with the generated combination number.

6 If the combination number and the generated combination number match the LCD will display "Opr" and beeps will be heard. Turn the knob clockwise to open the lock and retract the locking bolt. The security enclosure door can now be opened.

If the combination numbers do not match, a lightning bolt symbol (to indicate a security violation) will appear on the LCD. If this occurs, follow your in-house security procedures for this condition.

Locking 7

To lock a security enclosure with a Kaba Mas controlled access electronic lock (Type 1), proceed as follows:

1 Close the security enclosure door.

2 Turn the electronic lock knob counterclockwise to close.

3 Spin knob (to power up the electronic lock) until beeps are heard.

4 "IPI" will appear on the LCD.

5 Touch personal identification key to the key reader.

6 "EOP" (End of Operation) will appear on the LCD.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-17

Page 124: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock a Controlled Access Electronic Lock

Controlled Access Electronic Lock (Type 2) 7

The controlled access electronic lock (Type 2), can also be fitted with, or without a sub-lock on the cheque acceptor bin. The possible combinations of locks are:

● Master lock● Master lock with sub-lockTo unlock a security enclosure with a master lock and one sub-lock, you will require the following:

● Personal Identifier key (PI key) - issued by the Key Management Centre (KMC).

● 6-digit access code - obtained from the KMC.

Unlocking the Master Lock 7

To open the master lock, proceed as follows:

1 Contact the KMC.

2 Give requested details to verify your identity to the KMC.

3 Specify which areas, on the ATM, you want to access.

4 Take note of the 6-digit access code (three pairs of two), allocated by the KMC.

5 Unlock and open the exterior of the ATM.

7-18 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 125: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock a Controlled Access Electronic Lock

6 Spin the lock dial counterclockwise to charge the lock, until EC is displayed on the LCD.

Note: If DL (Dial Left) is displayed, you must only turn the dial to the left (counterclockwise).

7 Turn the dial to the home position.

8 Enter the 6-digit access code provided by the KMC on the keypad.

9 IPI should be displayed on the LCD.

2 34

5

1

* 6

#

78 9

0

KeypadLCD

Dial(Opening/Closing)

Key Reader

Home Position

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-19

Page 126: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock a Controlled Access Electronic Lock

10 Hold the PI key against the key reader to verify a valid user identity. If sub-lock access is required, the appropriate authority is passed to the PI key at this stage.

11 If the correct 6-digit code has been entered and a valid PI key has been pressed against the key reader, OPr will be displayed on the LCD.

Note 1: If an incorrect code or PI key is used and there is a bad PI key contact, a lightning bolt symbol will be displayed on the LCD, indicating an error condition.

If the error condition was caused by a bad PI key contact, YOU HAVE ONE MORE ATTEMPT AT OPENING THE LOCK. If the error condition occurs after the 2nd attempt, contact the KMC immediately.

12 Turn the lock dial a quarter turn (90o) clockwise to release the bolt.

13 Open the security enclosure.

2 34

5

1

* 6

#

78 9

0

LCD

Keypad

Dial(Opening/Closing)

Key Reader

PI Key

7-20 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 127: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock a Controlled Access Electronic Lock

Locking the Master Lock 7

To lock the master lock, proceed as follows:

1 Close the security enclosure.

2 Turn the lock dial counterclockwise to activate the bolt and charge the lock until IPI is displayed on the LCD.

3 Hold the PI key against the key reader.

4 Take a note of the unique 4-digit close code that is displayed, as it will be required by the KMC.

5 Close the exterior of the ATM.

6 Contact the KMC.

Note: Ensure that all the locks and doors on the ATM are closed and locked before contacting the KMC.

7 Verify identification.

8 Provide the 4-digit close code to the KMC.

9 The KMC will inform you that either the code is correct or give you the correct procedure to follow if the close code is wrong.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-21

Page 128: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock a Controlled Access Electronic Lock

Unlocking the Sub-Lock (if configured) 7

To unlock the sub-lock, proceed as follows:

1 Carry out Steps 1 to 10 of “Unlocking the Master Lock”.

Note: The code displayed on the LCD will depend on which areas of the ATM you requested access to.

2 Hold the PI key against the key reader of the sub-lock.

The LED flashes three (3) times. You have eight (8) seconds to unlock the sub-lock by turning the knob clockwise to release the catch. If the knob is turned back to its original position, you will need to contact the KMC for another access code.

Note: The knob cannot be turned before the LED flashes. After turning, the catch remains in position until the lock is closed.

3 Remove the cheque acceptor bin.

Key Reader

PI Key

Knob

LED

7-22 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 129: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationHow to Unlock and Lock a Controlled Access Electronic Lock

Locking the Sub-Lock (if configured) 7

To lock the sub-lock, proceed as follows:

1 Replace the cheque acceptor bin firmly. Ensure the bin is fully home and the knob is turned fully counterclockwise to lock the bin in place.

2 Hold the PI key against the key reader of the sub-lock until the LED has flashed four (4) times. This indicates the lock is closed.

3 On the master lock, turn the lock dial counterclockwise to charge the lock until IPI is displayed on the LCD.

4 Hold the PI key against the key reader of the master lock.

5 Take a note of the unique 4-digit close code that is displayed, as it will be required by the KMC.

6 Close the exterior of the ATM.

Note: Ensure that all the doors and locks on the ATM are closed and locked before contacting the KMC.

7 Contact the KMC.

8 Verify your identification.

9 Provide the 4-digit close code to the KMC.

10 The KMC will inform you that either the code is correct or give you the correct procedure to follow if the close code is wrong.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-23

Page 130: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationRemoving the ATM From Its Pallet

Removing the ATM From Its Pallet 7

To remove the ATM from its pallet using lifting trolleys proceed as follows:

1 Unlock and open the ATM security enclosure.

2 Use a 19 mm (3/4 in.) spanner and the same size socket to remove the four bolts attaching the ATM to the pallet.

3 Close the security enclosure.

7-24 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 131: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationRemoving the ATM From Its Pallet

4 Put the lifting trolleys on either side of the pallet and insert the toes of the trolleys under the ATM.

5 Strap the trolleys to the ATM and insert packing where necessary to protect the ATM’s paintwork. Pump up both trolleys to lift the ATM clear of the pallet. Slide the pallet out from under the ATM.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-25

Page 132: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Preparing the ATM For InstallationRemoving the ATM From Its Pallet

6 Place the safety boards under the ATM. Lower the ATM until it is resting on the safety boards.

7 Adjust the trolleys, straps and packing, ensuring the trolleys are as near as possible to the ATM.

8 Pump up both trolleys to lift the ATM clear of the safety boards. Slide the safety boards out from under the ATM.

9 Move the ATM to the installation site.

7-26 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 133: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstalling the ATM – Physical Installation

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Chapter 8

Installing the ATM – Physical Installation

Introduction 8-1Installation Categories 8-1Connecting Cables 8-1

Fitting the Severe Environment Parts 8-2Dismantling the Severe Environment Parts 8-2Removing the 80-Column Printer 8-4Removing the Side-Access Service Panel 8-7Fitting the Severe Environment Parts 8-11Sealing the ATM 8-17

Fitting a Cheque Acceptor Bin (If Configured) 8-22Cheque Acceptor Bin With a Keylock 8-22Cheque Acceptor Bin With a Sub-Lock 8-24

Positioning the ATM 8-27

Fitting An Infill Panel 8-28Infill Panel (5088) 8-28Infill Panel (5688) 8-29

Fitting the Collar 8-31Fitting the Standard Collar With Facia Light 8-31Fitting the Standard Collar With Advert Light 8-36

Sealing the Collar and Bolting the ATM to the Plinth 8-44

Page 134: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstalling the ATM – Physical Installation

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 135: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8

-1

IntroductionInstalling the ATM – Physical Installation8

Introduction 8

Installation Categories 8

The physical installation of 5886 Drive-Up is divided into three different categories.

For information on the installation categories, refer to Chapter 1.

Connecting Cables 8

If the ATM is being installed within a minimum footprint clearance area, due to limited side clearance, cable connections must be carried out before the unit is moved into its final location. If however, the ATM is located in a recommended footprint clearance area (or more), cable connections can be carried before or after the final siting of the unit.

If required, refer to “Connecting Cables to the ATM” and connect cables before proceeding with the installation.

Caution The design of the plinth must be such that it will not damage the cables which exit the ATM through the base of the security enclosure. For more details, refer to Chapter 1.

Page 136: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

Fitting the Severe Environment Parts 8

The severe environment module is shipped detached from the ATM. It is recommended that the module is fitted to the ATM prior to installation through the wall.

To fit the module proceed as follows:

Dismantling the Severe Environment Parts 8

When dismantling the severe environment module, make sure that you retain all parts, including screws, in preparation for fitting to the ATM.

1 Remove the severe environment parts from their packaging.

2 Disconnect the fan and heater connections from the connector box.

8-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 137: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

3 Disconnect the heater harness from the heater element connections.

4 Remove the three M4 nuts securing the fan assembly to the side access panel.

1 2

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-3

Page 138: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

Removing the 80-Column Printer 8

To remove the 80-column printer, proceed as follows:

1 Open the top-box of the ATM.

Note: The following illustrations show a letter quality document statement printer on a standard sleeve ATM, however, the steps for removing the printer are the same in all cases.

2 Pull and hold the latch stud upwards and push the operator interface to the left until it reaches its second stop position.

Note 1: You will know when the operator panel has reached the second stop position, as the plunger will sit in a second hole at the opposite end of the track.

Note 2: If your ATM is the short sleeve version, the operator panel will raise automatically when the top-box is opened.

8-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 139: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

3 Press the green latch and using the green handle, slide the printer forwards, until its slides are fully extended.

4 Disconnect the power and SDC connectors from the printer. Feed the cables back through the hole in the metalwork and cut the three cable ties securing the cables to the printer.

Note: The location and number of cables and cable ties may differ from that shown below.

5 Push the printer back into the ATM until it clicks into place

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-5

Page 140: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

6 Remove the two screws securing the printer to the support plate.

7 Slide the printer towards the rear of the ATM to release the mushroom studs from the key-holes.

8 Remove the printer from the ATM.

Warning: The printer is heavy. Make sure that you have an unobstructed area in which to move and place it before you lift it from the ATM.

8-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 141: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

Removing the Side-Access Service Panel 8

To remove the side-access service panel, proceed as follows:

1 Disconnect the terminals from the auto-supervisor switch and remove the switch from the bracket. Retain the switch for using in the same position later.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-7

Page 142: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

2 Remove the M6 locknut from the stud on the top-box and retain it for using in the same position later.

8-8 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 143: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

3 Remove the circlip securing the gas-strut and relocate it on the stud on the top-box. Secure it with the M6 locknut removed previously.

Caution: Ensure the top-box is supported before relocating the gas-strut.

4 Remove the securing stud from the gas-strut’s original location and retain it for using in the same position later.

1

2

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-9

Page 144: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

5 Remove the side-access service panel by slackening three M4 locknuts at the rear, and removing the two M6 screws on the base. Retain the two screws for using in the same position later.

6 Remove the side-access service panel.

8-10 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 145: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

Fitting the Severe Environment Parts 8

To fit the severe environment parts, proceed as follows:

1 Fit the new side-access service panel with the two retained M6 screws at the base and then tighten the three M4 locknuts at the rear.

2 Re-fit the gas-strut securing stud to the new side-access service panel and move the piston on to the stud.

3 Secure the gas-strut on the stud with a circlip.

Warning: Ensure that the circlip is secure before proceeding to the next step.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-11

Page 146: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

4 Connect the heater harness to the terminals. Ensure that both terminals are pushed through the hole in the side-access service panel and that the grommet is located in the hole.

1 2

8-12 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 147: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

5 Fit the severe environment fan assembly to the side-access service panel with the three M4 locknuts. Do not tighten the locknuts.

Note: Ensure that the fan and heater connections project through the cut out in the side-access service panel.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-13

Page 148: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

6 Secure the heater and fan harnesses to the bracket on the side-access service panel using a cable tie.

7 Fit the severe environment housing assembly to the two studs on the side wall of the top-box and secure with two M4 locknuts.

8-14 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 149: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

8 Fit the entry panel to the housing assembly with two M4 x 6 countersunk screws at the top, and two M4 x 6 screws at the bottom.

9 Slide the severe environment fan assembly towards the entry panel. Tighten the three locknuts.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-15

Page 150: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

10 Connect the fan, heater and thermostat connections to the terminal box. Ensure that the grommets are located in the slots in the connector box.

11 Fit the connector box assembly to the fan assembly using one M4 screw.

8-16 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 151: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

12 Connect the AC power harness to the connector box.

13 Refit the auto-supervisor switch to the bracket on the side-access service panel. Reconnect the harness to the terminals.

Sealing the ATM 8

The final stage of fitting the severe environment module, is to seal the ATM to prevent negative pressure within the ATM.

14 Cut the foam gaskets into sections and fit between the existing gaskets on the top-box.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-17

Page 152: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

15 Fit the two rubber seals to either side of the top-box.

16 Cover the gap between the top-box and the sleeve on both sides with adhesive tape. Cover the speaker slots on the facia with adhesive tape.

17 Open the security enclosure.

8-18 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 153: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

18 Fit the adhesive gasket (445-0655433) to the flange on the right hand side of the security enclosure and the adhesive gasket (445-06455434) to the side wall on the left hand side of the security enclosure.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-19

Page 154: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

19 Fit the brackets to the top and bottom of the security enclosure door using four M6 x 12 round head screws.

Note 1: Use the fixing holes to secure the brackets to the security enclosure.

Note 2: If external alarms are fitted, it may not be possible to fit these brackets.

8-20 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 155: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Severe Environment Parts

20 Remove the adhesive backing from the seals (445-0655684) and fix them to the brackets that were fitted previously.

21 Replace the printer, securing it with the two screws which were removed earlier.

22 Connect the power and SDC connectors and secure the cables with cable ties.

23 If your ATM is the standard sleeve version, return the operator panel to its home position.

Caution: If the operator panel is not returned to its home position, closing the top-box may damage the paintwork on the front of the panel.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-21

Page 156: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting a Cheque Acceptor Bin (If Configured)

Fitting a Cheque Acceptor Bin (If Configured) 8

The cheque acceptor bin is shipped detached from the ATM. The types of bin locks and mountings are:

● cheque acceptor bin with a keylock● cheque acceptor bin with a sub-lock

Cheque Acceptor Bin With a Keylock 8

To fit a cheque acceptor bin with a keylock, proceed as follows:

1 Remove bin parts from their packaging.

2 Insert and turn the key clockwise to release the latch and remove the bin from the mounting bracket.

Cheque AcceptorBin

Mounting

Keylock

Sub-lockKnobLED

8-22 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 157: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting a Cheque Acceptor Bin (If Configured)

3 Secure the mounting bracket to the outside of the security enclosure door with the three M6 x 8 screws and two Mono-drive screws.

Note: The head of the mono-drive screw has two quarters of the head removed allowing the screw to be driven in one direction only.

4 Rest the bin on the mounting bracket and guides, then push firmly home.

5 Remove the key from the keylock.

Mono-driveScrews

M6 Screws

Cheque Acceptor Bin

Security EnclosureDoor

Mounting

Guide

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-23

Page 158: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting a Cheque Acceptor Bin (If Configured)

Cheque Acceptor Bin With a Sub-Lock 8

To fit a cheque acceptor bin with a sub-lock, proceed as follows:

1 Remove the bin parts from their packaging.

2 Separate the bin from the mounting bracket.

3 Remove and retain the three M4 x 6 screws from inside the safe door cover, then remove the cover.

Screw

Screws

Security DoorCover

8-24 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 159: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting a Cheque Acceptor Bin (If Configured)

4 Secure the mounting bracket to the outside of the security enclosure door with the three M6 x 8 screws and the two Mono-drive screws.

Note: The head of the mono-drive screw has two quarters of the head removed allowing the screw to be driven in one direction only.

5 Feed the power cable through the safe door as shown below. Connect the 2 pin connector to the power harness leading to the PC Core. Connect the 9 pin connector to the Sublock Interface Box.

6 Replace the safe door cover.

7 Carry out steps 1 and 2 of “Unlocking the Sub-Lock” inChapter 7.

Mono-driveScrews

M6 Screws

SublockInterface Box

PC CoreConnector

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-25

Page 160: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting a Cheque Acceptor Bin (If Configured)

8 Rest the cheque acceptor bin on the mounting bracket and guides, then push firmly home. Ensure the knob is turned fully clockwise to lock the bin in place.

9 Carry out steps 2 to 10 of “Locking the Sub-Lock” in Chapter 7.

Cheque Acceptor Bin

Security EnclosureDoor

Mounting

Guide

8-26 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 161: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationPositioning the ATM

Positioning the ATM 8

To position the ATM through the hole in the wall proceed as follows.

1 Using the lifting trolleys, move the ATM onto the plinth and through the hole in the wall so that the sleeve protrudes at the other side.

Note: The holes in the base of the security enclosure should line up with the fixing holes in the plinth.

2 Remove the ATM from the lifting device.

Warning If you have to slide the ATM off the lifting trolleys, take care that the ATM does not fall over.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-27

Page 162: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting An Infill Panel

Fitting An Infill Panel 8

An infill panel is required when installing 5886 Drive-Up into a hole used by a previous 5088 or 5688 installation.

Infill Panel (5088) 8

For fitting a 5088 infill panel, proceed as follows:

1 Place the infill panel over the sleeve and mark its outline on the wall.

2 Using the infill panel as a template, mark centre points for the four fixing holes.

3 Remove the infill panel.

4 Drill fixing holes and insert the M6 wall fixings. Remove the bolts from the fixings.

5 Replace the infill panel and check its position before finally bolting it to the wall using the M6 wall bolts and washers.

6 Seal the outer edge of the panel to the wall using silicone sealant.

The hole in the wall is now prepared for the installation of the ATM.

8-28 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 163: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting An Infill Panel

Infill Panel (5688) 8

For fitting a 5688 infill panel, proceed as follows:

1 Place the infill panel over the sleeve and mark its outline on the wall.

2 Remove the infill panel.

3 Using lifting trolleys, move the ATM back from the hole in the wall.

4 Loosely fit the two mounting brackets to the infill panel using four M6 screws, four washers and four nuts.

5 Place the infill panel over the hole in the wall, ensuring that it is placed within the outline drawn previously.

6 With the help of an assistant or with the use of tape, temporarily secure the infill panel to the wall.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-29

Page 164: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting An Infill Panel

7 If required, adjust the two mounting brackets until they are tight against the inside face of the wall.

8 Using the two mounting brackets as templates, mark centre points for the six fixing holes.

9 Remove the infill panel.

10 Drill fixing holes and insert the M6 wall fixings. Remove the bolts from the fixings.

11 Replace the infill panel and check its position before finally bolting it to the wall using the M6 wall bolts.

12 Tighten the two mounting brackets to the infill panel using the four screws, four washers and four bolts that were loosely fitted previously.

13 Seal the outer edge of the panel to the wall using silicone sealant.

14 Using the lifting trolleys, move the ATM through the hole in the wall so that the sleeve protrudes at the other side.

The hole in the wall is now prepared for the installation of the ATM.

Wall Mounting Bracket

8-30 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 165: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Collar

Fitting the Collar 8

The following sections describe the two different collar assemblies available for the 5886 Drive-Up:

● Standard collar with facia light● Standard collar with advert light

Fitting the Standard Collar With Facia Light 8

These instructions should be followed for installations where a 5886 Drive-Up is installed at the NCR recommended height.

1 Fix the vertical collar mounting brackets to the sleeve using four M4 x 6 countersunk thread forming screws on each side. The brackets are not interchangeable and must be fitted as shown, with the tabs facing forward.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-31

Page 166: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Collar

2 Fix the bottom collar mounting bracket to the sleeve, as shown, using three M4 x 6 thread forming screws.

Note: Ensure the bracket tabs are aligned with the lower bracket tabs on the vertical collar mounting brackets.

8-32 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 167: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Collar

3 Fit the “U” shaped collar piece to the brackets by sliding it onto the bracket tabs, as shown.

1 2

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-33

Page 168: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Collar

4 Apply silicone sealant to both sides of the lower collar piece, as shown.

5 Slide the top collar assembly into position.

6 Using a damp cloth, wipe any excess silicone sealant from the join between the lower and top collar.

8-34 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 169: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Collar

7 Fix the top collar assembly with four M4 x 10 screws through the white light panel and into the mounting bracket.

8 Insert the facia light fluorescent tube and turn it until its contacts are tightly held.

9 Hook the facia light window under the lip of the top collar piece and swing it up into position. Fit a clip over the facia and secure it with four M3 countersunk machine screws.

10 Proceed to the section “Sealing the Collar and Bolting the ATM to the Plinth”.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-35

Page 170: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Collar

Fitting the Standard Collar With Advert Light 8

These instructions should be followed for installations where a 5886 Drive-Up is installed at the NCR recommended height.

Note: The standard collar with advert light requires a decal. Fix the advert decal to the surface of the light panel before fitting the collar. Make sure that the panel is clean, dry and dust free prior to applying the decal. The decal may have to be fitted to the inside or outside of the light panel depending on the decal design.

1 Fix the left and right collar mounting brackets to the sleeve using four M4 x 6 countersunk thread forming screws on each side. The brackets are not interchangeable and must be fitted as shown, with the tabs facing forward.

8-36 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 171: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Collar

2 Fix the bottom collar mounting bracket to the sleeve as shown, using three M4 x 6 thread forming screws.

Note: Ensure the bracket tabs are aligned with the lower bracket tabs on the vertical collar mounting brackets.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-37

Page 172: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Collar

3 Fit the “U” shaped collar piece to the brackets by sliding it onto the bracket tabs, as shown.

1 2

8-38 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 173: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Collar

4 Apply silicone sealant to both sides of the lower collar piece, as shown.

5 Slide the top advert collar assembly into position. Push the two harness connectors from below and through the hole in the bottom right hand side of the collar.

6 Using a damp cloth, wipe any excess silicone sealant from the join between the lower and top collar.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-39

Page 174: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Collar

7 Fix the top advert collar assembly with four M4 x 10 screws through the white light panel and into the mounting bracket.

8-40 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 175: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Collar

8 Fit the two harness connectors to the top advert collar and secure with two M3 x 20 screws and two nuts.

Caution: Do not over-tighten the two screws as this may cause damage to the harness connectors.

9 Connect the harness earth lead to the earth stud on the top advert collar and secure with a M4 nut.

10 Insert the facia light fluorescent tube and turn it until its contacts are tightly held.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-41

Page 176: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Collar

11 Clip in the advert light window.

Caution Ensure that the window is secured at the top and down both sides, and that both the bottom clips are engaged.

8-42 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 177: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationFitting the Collar

12 Hook the facia light window under the lip of the top collar piece and swing it up into position. Fit a clip over the facia and secure it with four M3 countersunk machine screws.

13 Proceed to the section “Sealing the Collar and Bolting the ATM to the Plinth”.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-43

Page 178: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationSealing the Collar and Bolting the ATM to the Plinth

Sealing the Collar and Bolting the ATM to the Plinth 8

The final stage of installation is to seal the ATM to the wall and bolt it down. The following picture shows the standard collar with advert light, however, the method of fitting the weather seal is the same in all cases.

1 Apply four strips of self-adhesive weather seal gasket to the rear faces of the collar, and two small strips to the rear of the lower and top collar join.

Caution: Ensure the top gasket strip is positioned at the top edge of the collar and forms a “T” on top of the vertical strips, to prevent water gathering behind the collar.

2 Pull the ATM hard against the building wall to compress the weather seal.

8-44 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 179: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationSealing the Collar and Bolting the ATM to the Plinth

3 Open the security enclosure and bolt the ATM to the floor/plinth.

Note: Bolts are not provided with the unit, they must be supplied by the owning organization. You will require:

● 4 bolts 16mm (0.63in.) diameter x 120mm (4.72in.) long● 4 anchor washers to fit the bolts. These must be at least 3mm

(0.12in.) thick and have a maximum outside diameter of 40mm (1.57in.) and an inner diameter of 18 mm (0.71 in.).

4 Trim off any excess weather seal.

5 Seal the top and vertical edges of the collar to the wall, or infill panel, using silicone sealant from the collar kit box.

Caution: Do not seal the bottom edge of the collar.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-45

Page 180: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Physical InstallationSealing the Collar and Bolting the ATM to the Plinth

8-46 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 181: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstalling the ATM – Internal Packaging and Cables

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Chapter 9

Installing the ATM – Internal Packaging and Cables

Removing the Internal Packaging 9-1Module Locations 9-2Top-Box 9-3Security Enclosure 9-4Operator Panel 9-5Currency Dispenser 9-6PC Core 9-8Magnetic Card Reader/Writer 9-9Receipt and Journal Printers 9-1080 Column Printer Release Latch 9-11Statement Printer 9-12Depository and Depository Bin 9-14Cash Acceptor 9-16Cheque Acceptor 9-17

Connecting Cables to the ATM 9-18Power Cable 9-18Connecting All Other Cables 9-21

Page 182: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsInstalling the ATM – Internal Packaging and Cables

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 183: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9

-1

Removing the Internal PackagingInstalling the ATM – Internal Packaging and Cables9

Removing the Internal Packaging 9

This section describes how to remove the internal packaging from all modules. Ignore those steps which apply to modules not configured into the ATM.

Note: The amounts and types of packing may be subject to change without notice.

Page 184: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

Module Locations 9

The following illustrations show some of the possible locations of modules in the 5886 Drive-Up ATM.

Note 1: Modules in the security enclosure (that is, the envelope dispenser/depository, currency dispenser or cash acceptor) may be

CD Rom Drive

Card Reader

Statement Printer

Top-Box Digital Audio Volume Control

Supervisor/Operator Panel

(Standard Sleeve)

Currency Dispenser

Currency Purge Bin

Currency Cassette

Power On/Off Switch

Receipt / JournalPrinter

3.5 in. Disk Drive

PC Core

Card Capture Bin

EnvelopeDepository

Depository BinPower SupplySecurity Enclosure Door

Supervisor/Operator Panel(Short Sleeve)

Cash Acceptor(See Note 1)

Cheque Acceptor(See Note 1)

9-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 185: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

located on either the left- or the right-hand side, depending on the configuration of your ATM. The cheque acceptor may only be located on the right-hand side.

Note 2: The illustrations throughout this manual show a standard sleeve ATM, where the operator panel is located in front of the statement printer.

Top-Box 9

Remove the two foam blocks from inside the top-box.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-3

Page 186: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

Security Enclosure 9

Remove and retain the plastic document bag taped to the bottom of the security enclosure.

9-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 187: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

Operator Panel 9

If your ATM is the standard sleeve version, remove the foam blocks from the front and rear of the operator panel. Remove the tape from the release plunger.

Note: The ATM is shipped with the operator panel out of its operational position. After removing the packaging, slide the panel to the right hand side until the plunger slots into its home position.

If your ATM is the short sleeve version, remove the foam block from the front of the operator panel.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-5

Page 188: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

Currency Dispenser 9

If your ATM is fitted with dual dispenser, you should follow the procedures described below to remove the packing material from both dispensers.

Remove the tape from around the dispenser latch-handle.

Note: The position and appearance of the latch handle may differ from that shown.

Remove the foam block and tape from the front of the currency dispenser.

9-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 189: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

Remove tape from cassette latches on right-hand side and across the cassette and purge bin handles.

If your ATM has a dispenser with four cassettes, pull out the bottom cassette and remove the packaging from beneath the dispenser chassis.

Remove the strip of weather seal from inside the purge bin.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-7

Page 190: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

PC Core 9

Remove and retain the power cable and small plastic bag taped to the PC Core. Remove the foam block from behind the PC Core.

9-8 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 191: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

Magnetic Card Reader/Writer 9

Remove tape from the release plunger for the open card capture bin and the foam block from inside the bin.

Remove the cable tie and tape from the card capture bin (secure container shown).

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-9

Page 192: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

Receipt and Journal Printers 9

Remove the tape and foam packing piece from the printer tray release latch.

Remove the pieces of tape securing the paper rolls to the modules.

9-10 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 193: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

80 Column Printer Release Latch 9

Remove the tape and foam packing from the printer release latch.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-11

Page 194: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

Statement Printer 9

Remove the tape from both printer carriage levers.

Remove the tape from the following areas of the printer:

● Print engine latch● Thumbscrews at each side of the knife assembly● Transport shutter (type 2 printer only)

9-12 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 195: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

● Rear of the paper hopper● Paper hopper latch● Thumbscrew at the paper guides● Thumbscrew on the underside of the paper hopper.

If the ATM is configured with an overhead operator panel, remove the foam block shown in the following illustration.

If the ATM is configured with a receipt printer, remove the foam block between the printers.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-13

Page 196: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

From the front of the facia, remove the sheet of cardboard from the statement printer aperture.

Depository and Depository Bin 9

Your ATM may be fitted with the envelope depository located on the opposite side from what is shown in the illustrations, however the procedure for removing the packing material is the same.

Remove the tape from the depository latch. Remove the foam block from the front of the depository.

9-14 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 197: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

Remove three pieces of tape from the depository bin.

Remove the box containing the ink jet print head from behind the deposit bin. Remove the tape from the envelope dispenser.

Refer to the publication, “NCR 5886 Operator Manual”, B006-6194, for details of how to fit the print head cartridge.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-15

Page 198: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

Cash Acceptor 9

Remove the tape and foam block from the latch handle, and the tape and foam form the bottom of the cash acceptor.

Note: The position and appearance of the latch handle may differ from that shown.

Remove tape and foam blocks from the locations shown below.

9-16 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 199: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesRemoving the Internal Packaging

Cheque Acceptor 9

Remove tape from the around cheque acceptor latch. Remove the foam block from the front of the cheque acceptor.

Note: The position and appearance of the latch handle may differ from that shown.

Remove tape from the locations shown below.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-17

Page 200: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesConnecting Cables to the ATM

Connecting Cables to the ATM 9

The cables used to make connections to the ATM must conform to the cable specifications and details of preparation provided in Chapter 2.

Note: Because there is a limited side clearance when the ATM is being installed within a minimum footprint clearance area, cable connections must be carried out before the unit is moved into its final location. If however, the ATM is located in a recommended footprint clearance area, cable connections can be carried before or after the final siting of the unit.

Cables to be connected to the ATM fall into two categories:

● Power cable, not requiring additional grounding● All other cables, i.e. Remote Relay, Remote Status Indicator,

Alarms Interface Cable and High Order RS-232 Communication cables, require additional grounding by means of a “P” clamp.

Caution Cables must be grounded where indicated to make sure that the ATM meets EMC requirements.

Power Cable 9

To connect the power cable to your ATM, proceed as follows:

1 Open both the top-box and the security enclosure of the ATM.

9-18 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 201: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesConnecting Cables to the ATM

2 Check that the mains ON/OFF switch is in the OFF position (pressed in at the 0 side).

10

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-19

Page 202: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesConnecting Cables to the ATM

3 Remove the two M4 nuts securing the two cover plates to the cable entry bracket. Remove the cover plates.

1 2

9-20 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 203: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesConnecting Cables to the ATM

4 Insert the end of the power cable through the hole in the base of the security enclosure.

5 Connect the power cable to the socket on the power supply on the security enclosure wall.

Warning Make sure that the power supply cable is not connected to the AC outlet while you are connecting it to the ATM.

6 If you are connecting cables after installing the ATM, connect the power cable to the AC outlet. Otherwise, leave the power cable disconnected from the AC outlet until after the ATM is installed and bolted down.

7 If you have no other cables to connect, proceed from step 9 in the next section. Otherwise, proceed to the next section.

Connecting All Other Cables 9

To connect a Remote Relay, Remote Status Indicator, High Order RS-232 Communication or Alarms Interface cable to the ATM proceed as follows:

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-21

Page 204: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesConnecting Cables to the ATM

1 Check that the mains ON/OFF switch is at the OFF position (pressed in at the 0 side).

10

9-22 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 205: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesConnecting Cables to the ATM

2 Insert the ends of the cables through the hole in the base of the security enclosure. Pull sufficient cable through the hole to allow the connector to be fed through the matching hole in the top of the security enclosure.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-23

Page 206: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesConnecting Cables to the ATM

3 Connect the communications cables to the appropriate connectors on the panel.

9-24 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 207: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesConnecting Cables to the ATM

4 Take the earth studs and screw them into the threaded holes on the inside wall of the security enclosure as shown.

Note 1: The studs are packed in a plastic bag attached to the PC Core chassis.

Note 2: Ensure the area around the two threaded holes and the earth stud base is clean for a good electrical contact.

5 Tighten the studs down on to the base using a 10 mm (3/8 in.) spanner or socket.

M4 Nut

Earth

Stud

P Clamp

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-25

Page 208: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesConnecting Cables to the ATM

6 Clip the appropriate sized “P” clamp around the stripped section of each cable to be connected, then, using a 7 mm (9/32 in.) spanner, attach the clamp to the earth stud with the M4 nuts supplied.

Note 1: If the cable has not been stripped, refer to the instructions in Chapter 2.

Note 2: The largest clamp should be attached to the earth stud first, then the second largest and so on. Attach all the clamps to the stud even if some are not used – they may be required at a later date.

M4 Nuts Separatingand securing groupsof two cable clamps

3.4 mm (0.13 in.)Clamps facing upward

4.5 mm (0.18 in.)Clamps facing downward

6.0 mm (0.24 in.)Clamps facing downward

Earth Stud in SecurityEnclosure wall

9-26 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 209: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesConnecting Cables to the ATM

7 After all the cables have been connected, tie them together using the two cable ties provided.

8 Screw the cable ties to the inside wall of the security enclosure with two M6 screws, as shown.

Cable Tie

M6 Screw

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-27

Page 210: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Installing the ATM – Internal Packaging and CablesConnecting Cables to the ATM

9 Replace the cover plates, ensuring the studs locate in the slots. Slide the plates toward each other, overlapping one with the other, and secure with the two M4 nuts.

10 Switch on the power at the AC outlet and then at the ATM.

11 Close the security enclosure and top-box.

1 2

9-28 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 211: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsConfiguring the ATM

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Chapter 10

Configuring the ATM

Introduction 10-1

Currency Cassette Configuration 10-2

Device Configuration 10-3

Communications Configuration 10-4Self-Service Support 10-4S4I 10-4

Currency Dispenser Configuration 10-5Strapping 10-5

Currency Cassette Configuration 10-6

40-Column Printer Configuration 10-7Thermal Receipt and Journal Printers 10-7Basic Configuration 10-8Advanced Configuration and Calibration 10-8Dot-Matrix Journal Printer 10-12

80-Column Printer Configuration 10-13Adjusting DIP Switch Settings 10-14Adjusting Jumper JP1 (Type 2 Printer only) 10-16Adjusting Hopper Paper Guides 10-16Adjusting the Contrast 10-22Capture Bin Threshold 10-23

Envelope Dispenser 10-24Adjusting the Spacer Length 10-28

Page 212: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsConfiguring the ATM

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 213: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10

-1

IntroductionConfiguring the ATM10

Introduction 10

After you have completed the hardware installation of the ATM there are certain configuration procedures that must be performed. These depend upon which modules are installed in the ATM.

Note: All dot-matrix printers are pre-fitted with secured paper and ribbons but paper will have to be loaded or fed into the transport.

Refer to the publication, NCR 5886 Operator Manual, (B006-6194), for details of how to load supplies and how to fit the print head cartridges.

The features which may require configuration are:

● Currency cassette ● Device Configuration● Communications● Currency Dispenser● Printers:

● 40-Column printers● 80-Column printer

The configuration of these features is described in the following sections.

After completing the installation and configuration of the ATM, if your system software is Self-Service Support, refer to publication Self-Service Support, System Application User Guide, (B006-6167), for details of system initialization. If your system software is S4I, refer to publication Supervisor Functions, (B006-4718) instead.

After installation and testing, complete and return the Installation Report Form delivered with the ATM.

Page 214: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMCurrency Cassette Configuration

Currency Cassette Configuration 10

The currency cassettes should be configured as described in publication NCR Currency Cassette Owner’s Manual, (B006-1297).

10-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 215: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMDevice Configuration

Device Configuration 10

The ATM has a number of devices which need to be configured at installation.

If your ATM runs Self-Service Support, then configuration is done using the System Application. Refer to the NCR publication Self-Service Support System Application User Guide (B006-6167).

If your ATM runs S4I system software, then configuration can be done by referring to the NCR publication Supervisor Functions, (B006-4718).

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-3

Page 216: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMCommunications Configuration

Communications Configuration 10

If you intend to use communications, then you must configure the software and hardware. The procedure for configuring your ATM depends on whether your ATM runs Self-Service Support or S4I:

Self-Service Support 10

Configuration is described in the NCR publication APTRA Communications Feature User’s Guide, (B006-0012).

Note: Before you can start to configure the communications, you must have Self-Service Support installed on your ATM.

For information on NCR certified Communications boards, please refer to the following NCR Intranet site, or contact your local support representative:

http://www.dundee.ncr.com/INFOPROD/Software&Services.htm

S4I 10

Configuration is described in the NCR publication Supervisor Functions (B006-4718).

Note: Before you can configure communications in the ATM, you must build and load the applications software on to the ATM. The procedures for building and loading software can be found in NCR publication Building a Load Disk, (B006-1797).

To configure communications you will require the protocol identification code. If you order communications software, the appropriate documentation, including information on codes, is automatically sent. For more information visit the following NCR Intranet site.

http://www.dundee.ncr.com/INFOPROD/Software&Services.htm

You will also require the communications common and connection parameters and these must be supplied by the owning organisation.

10-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 217: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMCurrency Dispenser Configuration

Currency Dispenser Configuration 10

When the 5886 ATM is shipped with a currency dispenser, the currency dispenser is pre-configured at the factory and should not require configuration at installation time. Configuration would, however, be required if the control board had to be replaced or the contents of NVRAM were found to be corrupt.

Strapping 10

The strapping associated with the 5886 and NID currency dispenser control boards has the following default position:

● First dispenser, SDC command switch pack (U16) - set switches 1 to 8 to off for normal running

● Second dispenser, SDC command switch pack (U16) - set switch 1 to on and switches 2 to 8 to off for normal running.

Note: The second dispenser, switch pack settings are only valid when there are two dispensers installed.

DiagnosticSwitches

DiagnosticLEDs

SW8

SW1

D1

D8

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-5

Page 218: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMCurrency Cassette Configuration

Currency Cassette Configuration 10

The currency cassettes should be configured as described in publication NCR H-8015-STD1-01/02-08 Currency Cassette Owner’s Manual, (B006-1297).

10-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 219: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM40-Column Printer Configuration

40-Column Printer Configuration 10

The ATM may be fitted with up to two 40-column printers – a thermal receipt printer and either a thermal or dot-matrix journal printer.

Note: Full details of all configuration options can be found in chapter 13 of the NCR publication Service Aids Mini-Manual, (BFM0-0547).

The thermal printers are configured using DIP switches, RESET and ENTER (SET) buttons and feedback from status LEDs. An EEPROM on the interface PCB stores most configuration data.

The dot-matrix printer is configured using DIP switches.

Note: The following adjustments must be performed by a customer engineer.

Thermal Receipt and Journal Printers 10

All the necessary switches and LEDs are accessible through holes in the interface PCB cover:

{LED’s

SW1(ENTER (SET))

SW2(RESET)

DSW2

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-7

Page 220: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM40-Column Printer Configuration

Basic Configuration 10

Adjustments to the following functions can made using DIP switch DSW2:

● Black Mark mode – switch 1● 5670 Emulation – switch 2● Receipt and/or Journal printer installed – switches 3 & 4.

These adjustments do not update EEPROM data.

To adjust these functions set switches 1 to 4, as appropriate, following the table below:

Note: 0 = off, 1 = ON, x = Don’t care.

Advanced Configuration and Calibration 10

Receipt Form Length setting, Character Set selection and Black Mark Calibration involve updating the EEPROM data. Configuration of these functions is made using DIP switch DSW2.

Configuration is carried out as follows:

Receipt Form Length 10

The Receipt Form length can be set to any number of lines between 24 (default) and the maximum of 55.

1 Make a note of the current DSW2 DIP switch settings.

2 Set DSW2 switch 6 to ON.

3 Set DSW2 switches 1 to 5 to add the required number of lines to the default value of 24.

DIP switch DSW2 Switch Setting

Function 8 7 6 5 4 3 2 1

Receipt printer - Black Mark mode ON (default)

0 0 0 0 x x x 1

Receipt printer - Black Mark mode OFF

0 0 0 0 x x x 0

Report 5670 Emulation (default) 0 0 0 0 x x 0 x

Report TEC Emulation 0 0 0 0 x x 1 x

Installed printers - invalid setting 0 0 0 0 0 0 x x

Installed printers - Receipt printer only

0 0 0 0 0 1 x x

Installed printers - Journal printer only

0 0 0 0 1 0 x x

Installed printers - both printers 0 0 0 0 1 1 x x

10-8 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 221: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM40-Column Printer Configuration

switch 1 = ON : adds 1 lineswitch 2 = ON : adds another 2 linesswitch 3 = ON : adds another 4 linesswitch 4 = ON : adds another 8 linesswitch 5 = ON : adds another 16 lines

For example: to make the form length 35, set the switches like this:

default:.....................24switch 1 = ON adds .1switch 2 = ON adds .2switch 3 = OFF adds 0switch 4 = ON adds .8switch 5 = OFF adds 0

TOTAL: ...................35

4 Press the RESET button SW2.

5 Press and hold the ENTER (SET) button SW1 until the four LEDs blink. The new form length is now stored in the EEPROM.

6 Restore the previously noted DSW2 DIP switch settings and press the RESET button SW2.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-9

Page 222: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM40-Column Printer Configuration

Character Set 10

This setting applies to both the Receipt and Journal printers.

1 Make a note of the DSW2 DIP switch settings.

2 Set the DSW2 DIP switches as shown:

Note: 0 = off, 1 = ON.

3 Press the RESET button SW2.The four LEDs blink – the character set data is now stored in the EEPROM.

4 Restore the previously noted DSW2 DIP switch settings and press the RESET button SW2.

Black Mark Calibration 10

1 Make a note of the DSW2 DIP switch settings.

2 Ensure that the Receipt printer is properly loaded with suitable paper.

3 Set the DSW2 DIP switches as shown:

Note: 0 = off, 1 = ON.

Switch Setting

Function 8 7 6 5 4 3 2 1

International Character Set (Default) 0 0 0 1 1 0 0 1

Arabic Character Set 0 0 0 1 1 0 1 0

Switch Setting

Function 8 7 6 5 4 3 2 1

Black Mark Calibration 0 0 0 1 0 1 0 1

10-10 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 223: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM40-Column Printer Configuration

4 Press the RESET button SW2. Wait until the LEDs have finished flashing then press the Paper Feed button. The printer feeds paper, calibrates the black mark sensor and stores the new data in the EEPROM.

The four LEDs blink to confirm successful calibration. If all four LEDs do not blink – interpret the error from the pattern of the blinking LEDs:

EEPROM data is only updated when calibration is successful.

5 Restore the previously noted DSW2 DIP switch settings and press the RESET button SW2.

6 To confirm a successful calibration, press the RESET button and then immediately press and hold the paper feed button. The printer will produce a configuration printout, for example:

Check the Sensor level ON and OFF values: if they are both “0000” then the calibration was not successful and the EEPROM data was not changed.

Error condition LED 1 LED 2 LED 3 LED 4

Paper out off off BLINKS

BLINKS

Black mark too wide or not found BLINKS

off off BLINKS

Unable to calibrate (unknown error)

BLINKS

off BLINKS

BLINKS

<Receipt printer>

F/W ROM version 1.60ANK CG version 1.00

Sensor level ON OFF THBDS 0772 0143 0457

- DIP switches -1 = Black mark mode2 = 5670 emulation3 = Receipt printer

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-11

Page 224: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM40-Column Printer Configuration

Dot-Matrix Journal Printer 10

The illustration below shows a dot-matrix journal printer fitted on the printer tray along with a thermal receipt printer.

The thermal receipt printer, if fitted, is configured as described in the previous section.

Character Set Selection 10

The Dot-Matrix printer is configured using an 8-pole switch pack:

● Switch 7 selects the Character Set – OFF to select International character set or ON to select the Arabic character set

● Switches 1 to 6 and 8 are not used.

The printer is delivered with all switches OFF (International character set selected).

10-12 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 225: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

80-Column Printer Configuration 10

There are two types of statement printer possible in your ATM. For each type, there is a standard variant and a parallel port (or “open”) variant. The two types of printer can be differentiated by the appearance of the front transport: type 1 has a cover over the transport rollers, and type 2 has an open transport, as shown in the following illustration.

There are some differences in the operating instructions between the two types of printer. Refer to the appropriate type in the following sections for the instructions specific to your printer.

Type 1 Printer 10

The type 1 printer leaves the factory with the paper width set to 216 mm (8.5 in.) and the paper length set to 305 mm (12 in.).

To change these settings, the paper guides in the hopper can be adjusted for width and length, and the DIP switch settings can be changed for width. These tasks must be performed by a customer engineer.

Note: There is no need to adjust the switch settings on a Parallel Port or “Open” variant of the statement printer.

Type 2 Printer 10

The type 2 printer leaves the factory with the paper width set to 216 mm (8.5 in.) and the paper length set to 102 mm (4 in.).

To change these settings, the paper guides in the hopper can be adjusted for width or length, the DIP switch settings can be changed for width and a jumper on the board can be adjusted for length. These tasks must be performed by a customer engineer.

Note: There is no need to adjust the switch settings on a Parallel Port or “Open” variant of the statement printer.

Type 1 Type 2

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-13

Page 226: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

Adjusting DIP Switch Settings 10

You need to adjust the DIP switch settings on the main pcb (switch pack U63 on type 1 printers and pack U50 on type 2 printers) to fit the width of paper to be used on it. The following table provides the appropriate width settings for various sizes of paper (the default width setting is 216 mm (8.5 in.)). When choosing a width setting, select the nearest width up from your paper size. For example, choose the 148 mm (5.82 in.) setting for paper width of 147.5 mm (5.81 in.).

Note: 1 = On, 0 = Off, x = Don’t care.

Paper Width Switch Setting

mm Inches 8 7 6 5 4 3 2 1

216 8.50 x 0 0 0 0 0 0 0

215 8.47 x 0 0 0 0 0 0 1

214 8.41 x 0 0 0 0 0 1 0

212 8.34 x 0 0 0 0 0 1 1

210 8.28 x 0 0 0 0 1 0 0

209 8.21 x 0 0 0 0 1 0 1

207 8.14 x 0 0 0 0 1 1 0

205 8.08 x 0 0 0 0 1 1 1

203 8.01 x 0 0 0 1 0 0 0

202 7.94 x 0 0 0 1 0 0 1

200 7.88 x 0 0 0 1 0 1 0

198 7.81 x 0 0 0 1 0 1 1

197 7.74 x 0 0 0 1 1 0 0

195 7.68 x 0 0 0 1 1 0 1

193 7.61 x 0 0 0 1 1 1 0

192 7.55 x 0 0 0 1 1 1 1

190 7.48 x 0 0 1 0 0 0 0

188 7.41 x 0 0 1 0 0 0 1

187 7.35 x 0 0 1 0 0 1 0

185 7.28 x 0 0 1 0 0 1 1

183 7.21 x 0 0 1 0 1 0 0

182 7.15 x 0 0 1 0 1 0 1

10-14 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 227: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

180 7.08 x 0 0 1 0 1 1 0

178 7.01 x 0 0 1 0 1 1 1

176 6.95 x 0 0 1 1 0 0 0

175 6.88 x 0 0 1 1 0 0 1

173 6.81 x 0 0 1 1 0 1 0

171 6.75 x 0 0 1 1 0 1 1

170 6.68 x 0 0 1 1 1 0 0

168 6.62 x 0 0 1 1 1 0 1

166 6.55 x 0 0 1 1 1 1 0

165 6.48 x 0 0 1 1 1 1 1

163 6.42 x 0 1 0 0 0 0 0

161 6.35 x 0 1 0 0 0 0 1

160 6.28 x 0 1 0 0 0 1 0

158 6.22 x 0 1 0 0 0 1 1

156 6.15 x 0 1 0 0 1 0 0

155 6.08 x 0 1 0 0 1 0 1

153 6.02 x 0 1 0 0 1 1 0

151 5.95 x 0 1 0 0 1 1 1

149 5.89 x 0 1 0 1 0 0 0

148 5.82 x 0 1 0 1 0 0 1

146 5.75 x 0 1 0 1 0 1 0

144 5.69 x 0 1 0 1 0 1 1

143 5.62 x 0 1 0 1 1 0 0

141 5.55 x 0 1 0 1 1 0 1

139 5.49 x 0 1 0 1 1 1 0

Paper Width Switch Setting

mm Inches 8 7 6 5 4 3 2 1

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-15

Page 228: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

Adjusting Jumper JP1 (Type 2 Printer only) 10

To configure the type 2 printer for long paper length (more than 254mm (10 in.)), the jumper JP1 on the interface board can be set to enable the front transport shutter to operate. Set the jumper at pins 2 and 3 to enable the shutter for long paper. Set the jumper at pins 1 and 2 to disable the shutter.

Adjusting Hopper Paper Guides 10

The illustrations in this section show the type 1 printer, however the instructions are identical for both types of printer.

To adjust the paper guides in the hopper:

1 Open the top-box of your ATM.

2 If your ATM does not have the auto-supervisor function, press the switch on the operator panel to the supervisor position.

3 Pull and hold the latch stud upwards and push the operator interface to the left until it reaches its second stop position.

Note: If your ATM is the short sleeve version, the operator panel will raise automatically when the top-box is opened.

10-16 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 229: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

4 Press the green latch and pull the printer out of the ATM until its slides are fully extended.

5 Lift the latch at the side of the hopper and slide the hopper out.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-17

Page 230: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

6 To change the hopper width, slide one of the paper guides to the left or the right in its slot. This automatically moves the facing guide an equal distance in the opposite direction. Adjust the space between the guides to the required width.

Note: The guides are centrally located so any adjustment automatically centres paper placement in the hopper.

7 To change the hopper length, loosen the thumbscrew on the underside of the hopper, and move the rear guide backward or forward in its slot to fit the required length.

8 Place the paper stack in the hopper. The paper stack must be high enough to flatten the paper low sensor.

10-18 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 231: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

Note: Place the paper in the tray so that the black dot faces upwards and will be on the underside and towards the top edge of the form as it feeds into the printer.

9 Adjust the guides in the hopper to fit the paper stack, and tighten the thumbscrew on the underside of the hopper.

10 Slide the hopper forwards to its operating position.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-19

Page 232: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

11 Loosen the thumbscrew which secures the top paper guides and then slide the guides apart.

12 Place the paper between the guides. Move either guide towards the edge of the paper. This will cause the other guide to move the same corresponding distance. Ensure that there is 0.5 mm (0.02 in.) clearance at each side of the paper.

13 Tighten the thumbscrew.

1

2

10-20 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 233: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

14 Hold the paper in place between the guides and press the paper feed switch. The paper should feed through the printer.

Type 1 10

Type 2 10

15 Remove the statement from the printer transport.

16 Push the printer back into the ATM until it clicks into place.

17 If your ATM is the standard sleeve version, return the operator panel to its home position.

Caution: If the operator panel is not returned to its home position, closing the top-box may damage the paintwork on the front of the panel.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-21

Page 234: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

18 Press the switch on the operator panel to the NORMAL position.

19 Close and lock the top-box.

Adjusting the Contrast 10

You may need to change the contrast control to improve print clarity. This can be done by adjusting the contrast control switch or, if the printer does not have a contrast control switch, by using the User Switches on the printer control board (switch pack U64 on an SDC printer and U51 on a parallel printer). User Switch settings should only be changed by an Installation Engineer.

Contrast Control Switch 10

The contrast control switch (located on the paper guide assembly) allows you to adjust the printer contrast.

The location of the contrast control switch is shown below:

Type 1

Type 2

Dark

Light

Normal

Dark

Light

Normal

10-22 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 235: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATM80-Column Printer Configuration

For both types of printer, to darken the image set the switch to the Down position. The contrast is increased by applying more heat to the paper, however, if the image is too dark, the print may blur slightly.

To lighten the image set the contrast switch to the Up position. If the contrast is too light, the print image may fade over time.

Note that the ATM must be re-started for the new contrast settings to take effect.

User Switches (U64) 10

Note: The following procedure should only be carried out by a qualified Installation Engineer, if the printer does not have a contrast control switch.

To access the control board, remove the safety cover. Reset SW1 and SW2 on User Switches (U64 on SDC, U51 on parallel printers) as follows:

Note: 0 = off, 1 = ON.

The default setting for all paper (unless specified otherwise) is MEDIUM. If the media specifications state that any grade of paper requires increased contrast setting, then use the DARK setting.

Note: The image can be lightened or darkened by adjusting SW1 and SW2. To darken the image, the contrast must be increased (more heat is applied to the paper). However, if the contrast is too dark, this can cause the end image to blur slightly. If the contrast is too light, this can cause the end image to fade over time.

Capture Bin Threshold 10

Prior to the ATM’s dispatch from the factory, the statement capture bin threshold is configured to a setting of 10 (or 6 for buncher). Details on how to change these thresholds can be found in the NCR publication, Self-Service Support, System Application User Guide, (B006-6167) or Supervisor Functions, (B006-4718) depending on your system software.

SW1 SW2

LIGHT 0 1

MEDIUM 0 0 factory setting

DARK 1 0

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-23

Page 236: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMEnvelope Dispenser

Envelope Dispenser 10

To cut the dispenser bin’s plastic spacers to the correct size, proceed as follows. The configured spacer length will accommodate your specific envelope length.

Note: The bin is shipped with spacers which have been configured for a standard envelope. If required, two extra spacers are shipped, taped to the side of the dispenser bin, for you to configure to your specific envelope size.

1 Open the top-box of the ATM.

2 If your ATM does not have the auto-supervisor function, press the switch on the operator panel to the supervisor position.

3 Open the security enclosure.

4 Press the green latch and using the green handle, pull the envelope depository/dispenser out of the ATM until its slides are fully extended.

10-24 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 237: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMEnvelope Dispenser

5 Slide the envelope depository bin out of the ATM.

Note: Refer to the publication 5886 ATM Operator Manual, (B006-6194) for the procedure on removing the depository bin.

6 Lift the green latch, on either side of the envelope dispenser, and remove the cassette using the strap handle on the front.

1

2

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-25

Page 238: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMEnvelope Dispenser

7 To open the cassette, pull out the plunger and open the door.

1

2

10-26 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 239: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMEnvelope Dispenser

8 To remove the spacers from between the cassette door and the envelope rail, remove eight screws as shown below.

Cassette Door

Spacer

Envelope Rail

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-27

Page 240: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMEnvelope Dispenser

Adjusting the Spacer Length 10

With the full ten segment’s fitted, the envelope space is suited to the minimum length of envelope, 203 mm (8.00 in.).

Each spacer segment removed, increases the space by 5 mm (0.20 in.). With all ten segments removed, the maximum length of envelope, (254 mm (10.00 in.)) can be loaded into the cassette.

Segments should be removed from the spacers so that your envelopes fit into the cassette with 1 or 2 mm to spare (but no more than 5 mm (1 segment)).

The spacers can be cut with a stanley knife or small steel saw. Remove any burrs left on the legs of the spacers with a smooth file.

10 10

9 9

8 8

7 7

6 6

5 5

4 4

3 3

2 2

1 1

Cut Here

10-28 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 241: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMEnvelope Dispenser

The table below tells you where to make the cut for the measured length of envelope.

Measured Length of Envelope

Millimetres Inches Cut above Segment Number:

203 - 207 8.00 - 8.15 Do not cut

208 - 213 8.19 - 8.38 9

214 - 218 8.42 - 8.58 8

219 - 223 8.62 - 8.78 7

224 - 228 8.82 - 8.97 6

229 - 233 9.01 - 9.17 5

234 - 238 9.21 - 9.37 4

239 - 243 9.41 - 9.57 3

244 - 248 9.60 - 9.76 2

249 - 253 9.80 - 9.96 1

254 10 Cut off segment 1

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-29

Page 242: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Configuring the ATMEnvelope Dispenser

10-30 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 243: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsFitting Decals to the ATM

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Chapter 11

Fitting Decals to the ATM

Fitting the Decals 11-1Advert Light 11-1Card Orientation Window and Clear Window 11-1Entry/Exit Decals 11-2Card Acceptance Decal 11-2

Page 244: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsFitting Decals to the ATM

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 245: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 11

-1

Fitting the DecalsFitting Decals to the ATM11

Fitting the Decals 11

This chapter describes how to fit decals to the front of the ATM. Specifications for the decals can be found in Chapter 4.

Decals are fitted to the facia of the 5886 Drive-Up ATMs as follows:

Advert Light 11

Fix the decal to the surface of the advert light panel (inside or out depending on the decal design) before fitting the advert light and collar. Make sure that the panel is clean and dry before applying the decal.

Card Orientation Window and Clear Window 11

To fit a decal behind the card orientation plastic window or the larger clear window (fitted if an envelope depository is not configured), proceed as follows:

1 Insert the two window extraction tools (supplied with the ATM) into the holes at the base of the window.

2 Push down on the two extraction tools to release the window’s catches, then pull the window out from the facia.

Statement Exit

Cash Deposit

Cash Exit/Deposit Entry/Cheque Entry

Advert Light

Receipt Exit

Card Reader(Motorised/Dip)

Cash Exit/Deposit EntryCash Deposit

Page 246: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Fitting Decals to the ATMFitting the Decals

3 Place the decal in position and then press the plastic window back into the facia.

Entry/Exit Decals 11

The facia of the ATM has been provided with recesses for self-adhesive decals to identify the entry and exit slots. Make sure that the surface is clean and dry and then apply the correct decal firmly.

Card Acceptance Decal 11

Position this decal onto the side panel at the right hand side of the facia. Make sure that the surface is clean and dry and then apply the decal firmly.

11-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 247: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsTransient and Power Protection

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Appendix A

Transient and Power Protection

AC Power Line Transient Protection A-1

Data Line Transient Protection A-3

NCR Power Protection and Cabling Products A-4AC Power Line Transient Protection A-4Data Line Transient Protection A-5Uninterruptible Power Supplies A-5Contact Information A-7

Page 248: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Table of ContentsTransient and Power Protection

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 249: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation A

-1

AC Power Line Transient ProtectionTransient and Power Protection A

AC Power Line Transient Protection A

In the process of power distribution, transient electrical energy (including, but not limited to, lightning strikes, intermittent short circuits, and switching transients) can be introduced on to power lines. Such transient energy can be very damaging to electronic hardware and can also cause data corruption. Under these circumstances, NCR recommends the use of ac power transient suppressors and data (communication) line transient suppressors. Such protective devices are intended to guard against power and data line transients that can result in hardware damage and various system or program errors.

Improvement of any deficiencies in power quality is a customer responsibility. Malfunction and/or component failure as a result of power quality problems are/is not covered by NCR Maintenance Agreement, NCR accepts no liability for any such occurrence nor for its consequences.

When power transient suppression is required, the suppressors used should meet the following minimum requirements:

● Dissipate energy to match the appropriate application categories as defined by IEEE Standard 587. These categories are described in the table below:

Location Category

Comparableto IECNo 664Category

Transient

Waveform Amplitudes

A=Outlets > 10 m (30 ft)from Cat. BA= Outlets > 20 m (60 ft) from Cat. C

II 0.5 s Risetime, then 100 kHzRingwave, eachpeak=60% of previous

6 kV

200A

B=Major feeders, short branch circuits, and load centres

III Volts=1.3 x 5 sCurrent= 8 x 20 sand0.5 s Rise = 100 kHz Ringwave

6kV3kA

6kV500A

C = Service Entrance and run to load centre

IV Volts = 1.2 x 5 s

Current = 8 x 20 s

10kV or more

10kA or more

µ

µµ

µ

µ

µ

Page 250: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient and Power ProtectionAC Power Line Transient Protection

● Be of the voltage limiting (clipping), or tracking filter type. The suppressor must not ‘clamp’ the voltage to zero, and must self-recover after passage of the transient. The suppressor may be of the hybrid type construction that makes use of various technologies in order to meet speed and dissipation requirements.

● Exhibit a ‘short circuit’ mode upon its failure, thus providing a positive indication of its failure such as a blown fuse or tripped breaker

● Be listed by the accepted safety organization for the country involved (e.g. UL, CSA, VDE, ETL, etc.) and the installation must conform to local, state, and national electrical codes and regulations.

A-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 251: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient and Power ProtectionData Line Transient Protection

Data Line Transient Protection A

The nature of the transient phenomenon may extend to the data communication lines connected to this equipment. It is the responsibility of the customer to install and connect a data line transient suppression system to correct or prevent any deficiencies. Such systems must meet the following minimum requirements:

● Be of the voltage limiting type and must self-recover after passage of the transient

● Exhibit a ‘short circuit’ mode upon its failure to insure a positive indication of its failure

● Insert less than 5 ohms resistance and minimal inductive and capacitive loading at the operating frequency, in each data line in order to avoid signal degradation

● Be installed in accordance with all applicable local, state, and national electrical codes and regulations.

Note: In certain countries, NCR is able to supply both power and data line transient suppressors as well as a comprehensive line of power conditioning equipment. For application data, contact your NCR Customer Services Division Representative.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation A-3

Page 252: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient and Power ProtectionNCR Power Protection and Cabling Products

NCR Power Protection and Cabling Products A

Power protection equipment suitable for use with NCR ATMs can be purchased from the NCR Power Protection and Cabling group. Some of these products are outlined below.

AC Power Line Transient Protection A

The following products can be purchased from the NCR Power Protection and Cabling group to help provide protection from power line spikes and surges:

These products have numerous features:

● unique five-stage hybrid circuitry● offers protection from spikes and surges● protection covers all modes - line to neutral, line to earth

(ground) and neutral to earth (ground)● integral RF/EMI damping capability● thermal overload protection● high capacity fusing● indicator lights display operational readiness● plastic housing is highly flame retardant, conforming to UL94-

5V.

NCR Product ID Description

4060-4030-0094 110V, 3 outlet, wall plug-in, 15 Amp suppressor, United States applications

4060-4050-0094 110V, 3 outlet, strip, 15 Amp suppressor with 1.8 metres (6 feet) of power cable, United States applications

4060-4070-0094 110V, 7 outlet, strip, 15 Amp suppressor with 1.8 metres (6 feet) of power cable, United States applications

4060-4310-7594 220V, 4 outlet, strip, United Kingdom plug fitted

4060-4311-7594 220V, 4 outlet, strip, German/European plug fitted

4060-4312-7594 220V, 4 outlet, strip, French plug fitted

A-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 253: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient and Power ProtectionNCR Power Protection and Cabling Products

Data Line Transient Protection A

The following Data Line Transient Voltage Surge Suppressors can be purchased from the NCR Power Protection and Cabling group to help protect the communications port against harmful transient surges from both external and internal sources not eliminated by Uninterruptible Power Supplies or other AC protection:

Note: The first two products are designed to snap-in to the interface port on NCR Series 4000 Transient Voltage Surge Suppressors in the United States. The second two products are designed to be stand-alone for use in Europe.

Uninterruptible Power Supplies A

Uninterruptible Power Supplies (UPS) can be purchased from the NCR Power Protection and Cabling group to help protect information and equipment by providing power conditioning and battery back-up.

These products offer:

● on-line topology● 10 minute battery backup at full load● true sine wave output● 100% clean, conditioned power to connected equipment● extended battery cabinets available for extended run times● on-board SNMP optional on all models● standard LAN/serial (RS-232) network interface● standard rack-mountable unit design● also available in 1500 VA, 2100 VA and 3000 VA sizes.

NCR Product ID Description

4060-K018-V000 25 pin, CMP, snaps in to United States surge suppressors

4060-K019-V000 25 pin, CFP, snaps in to United States surge suppressors

4060-K021-V000 25 pin, CMP, stand-alone, all applications

4060-K022-V000 25 pin, CFP, stand-alone, all applications

NCR Product ID Description

4084-1000-7194 1000 VA on-line UPS with rack/tower configuration, 120VAC 50/60 Hz

4084-1000-7494 1000 VA on-line UPS with rack/tower configuration, 230VAC 50/60 Hz

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation A-5

Page 254: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient and Power ProtectionNCR Power Protection and Cabling Products

These products offer:

● line-interactive topology● 8 minute battery backup at full load● true sine wave output● input voltage selectable to 110/127 VAC or

220/240 VAC● advanced battery management prolongs battery life and ensures

quick availability after discharge● advanced battery management for early failure detection and

advanced user warning● internal transformer provides voltage buck/boost● standard LAN/serial (RS-232) network interface● available in rack-mountable configuration● also available in 600VA, 1500VA, 2000VA, 2200VA sizes.

These products offer:

● line-interactive topology● 7 minute battery backup at full load● modified sine wave output● input voltage selectable at 110/127 VAC or

220/240 VAC

NCR Product ID Description

4071-1000-7194 1000 VA Enhanced line-interactive UPS, 120VAC 60 Hz

4071-1001-7194 1000 VA Enhanced line-interactive UPS, 120VAC 60 Hz, Rack-mountable

4071-1000-7494 1000 V A Enhanced line-interactive UPS, 230 VAC, 50/60 Hz

4071-1001-7494 1000 V A Enhanced line-interactive UPS, 230 VAC, 50/60 Hz, Rack-mountable

NCR Product ID Description

4070-1000-7194 1000 VA Line-interactive UPS, 120AC, 60 Hz

4071-1000-7494 1000 VA Line-interactive UPS, 230VAC, 50/60 Hz

A-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 255: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient and Power ProtectionNCR Power Protection and Cabling Products

● advanced battery management prolongs battery like and ensures quick availability after discharge

● advanced battery management for early failure detection and advanced user warning

● internal transformer provides voltage buck/boost● standard LAN/serial (RS-232) network interface● hot-swappable batteries● also available in 450 VA, 700 VA, 1500 VA sizes.

Contact Information A

For more information from NCR’s Power Protection and Cabling Group on the power protection, data line transient suppressors and uninterruptible power supply products available, warranty or configuration assistance, call the appropriate number below:

Telephone

Worldwide (excl. USA) +1 919 460 9489

USA only 1 800 257 0458

Facsimile

Worldwide +1 919 460 9653 or+1 919 460 8976

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation A-7

Page 256: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Transient and Power ProtectionNCR Power Protection and Cabling Products

A-8 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 257: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Index

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

-1Index

Index 0

Numerics40-Column Printer Configuration 10-780-Column Printer Configuration 10-13

AAC Power Line Transient Protection A-1AC Power Requirements 2-1Adjustable Plinth 1-40Air Flow 3-4Alarm Interface Cable 2-11Ambient Lighting 1-12Anchor Bolts 1-42ATM Installed Directly on to the Floor 1-40

BBarometric Pressure Limits 3-2

CCables

High Order Communications Cable 2-4Power Cable 2-2Remote Device Cables 2-6

Combination locksCustomer setting combination 7-10

Communications Configuration 10-4Communications Requirements 2-4Concrete Plinth 1-40Configuring the ATM

40-Column Printer 10-780-Column Printer 10-13Communications

S4I 10-4Self-Service Support 10-4

Currency Cassette 10-2Currency Dispenser 10-5Device 10-3Envelope Dispenser 10-24

Connecting CablesAll Other Cables 9-21Power Cable 9-18

Connecting Cables to the ATM 9-18Controlled Access Electronic Lock 7-15Currency Cassette Configuration 10-2Currency Dispenser Configuration 10-5Customer Responsibilities xvCustomer Setting Combination 7-7

DData Line Transient Protection A-3Decal Dimensions

Advert Light 4-4

Page 258: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Index

Card Orientation Window 4-2Clear Window 4-3Entry/Exit Slot Decals 4-5

Decal Specifications 4-1Device Configuration 10-3Dimensions

Ambient Lighting 1-12Heights to Main Facia Items 1-11Severe Environment Fitted 1-9Short Sleeve Before Collar has Been Fitted 1-6Standard Collar 1-7Standard Collar With Advert Light 1-8Standard Sleeve Before Collar has Been Fitted 1-5

EElectromagnetic Compatibility (EMC) and Safety 3-4Electronic Lock

Emergency Opening Procedure 7-14Not Working 7-13

EMI Emmision 2-3EMI Susceptibility 2-3Envelope Dispenser Configuration 10-24

FFactory Setting 7-7Fitting a Third Party Video Camera 1-45Fitting an Infill Panel 8-28Fitting the Cheque Acceptor Bin 8-22Fitting the Collar

Standard Collar With Advert Light 8-36Standard Collar With Facia Light 8-31

Fitting the Decals 11-1Fitting the Severe Environment Parts 8-2Floor Covering 1-42Floor Loading 1-42

GGrounding Requirements 2-2

HHeat Dissipation 3-4Heights to Main Facia Items 1-11High Order Communications Cable, Standard Cable (RS-232) 2-5Hole in the Wall

Installation Categories 1-29Installing Through a Glass Wall 1-29Installing Through a New Hole 1-34Replacing 5088 With Modifications to Hole in Wall 1-30Replacing Personas 5688 With No Modifications to Hole in Wall 1-32Sealing 1-36

How to Change the Combination Lock 7-8How to Lock the Combination Lock 7-8How to Operate the Silent Alarm 7-8

Index-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 259: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Index

IInfill Panel Dimensions

Infill Panel (5088) 1-43Infill Panel (5688) 1-44

Input Voltage Setting 2-1Inspecting the ATM for Damage 7-1Installation Accessories 5-1Installation And Service Clearances

Minimum Clearances 1-17Recommended Clearances 1-13

Installation and Service ClearancesExterior Wall

Standard Collar 1-26Standard Collar With Advert Light 1-27

Installation Planning Check List 5-2Installation Procedure 6-1Installation Report Form 7-2Installing a Video Camera 1-45Installing Through a New Hole 1-34Internal Packaging, Removing 9-1

LLocking

Locking a Sub-lock 7-23Locks

Controlled Access Electronic Lock 7-15Controlled Access Electronic lock With a Sub-lock 7-18Controlled Access Electronic lock Without a Sub-lock 7-16Electronic Lock 7-12Unlocking and Locking a Security Enclosure with a Controlled Access

Electronic Lock 7-15

MMandatory Modifications to Plinth or Floor

Adjustable Plinth 1-40ATM Installed Directly on to the Floor 1-40Concrete Plinth 1-40Floor Loading 1-42

Manoeuvring the ATM into Position 1-2Module Locations 9-2

OOpening and Closing an Electronic Lock 7-12Overview -xiv

PPackage Dimensions 1-1Planning Check List 5-2Plinth

Installation Required 1-38Positioning the ATM 8-27Power Cable 2-2Power Consumption 2-1Product Identification xvi

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation Index-3

Page 260: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Index

RRemote Device Cables

Alarm Interface Cable 2-11Remote Relay Cable 2-14Remote Status Monitor 2-9RS-232 Cable 2-6

Remote Status Indicator 2-7Removing the External Packaging 7-1Removing the Internal Packaging 9-1Replacing 5088 With Modifications to Hole in Wall 1-30Replacing Personas 5688 With No Modifications to Hole in Wall 1-32Requirements for the Floor

Installation Without Infill Panel Required 1-38Support Plinth 1-37

SSealing the Collar and Bolting the ATM to the Plinth 8-44Sealing the Hole in the Wall 1-36Security Bolts 1-42Security enclosure

Combination lock and keylock 7-8Combination locks 7-6Customer setting combination 7-10keylocks 7-6

Service Access Panels 1-28Service Clearances

Exterior WallStandard Collar 1-26Standard Collar With Advert Light 1-27

Minimum Clearances 1-17Recommended Clearances 1-13

Silent Alarm 7-13Standard Collar With Advert Light 1-26Standard Security Enclosure 7-5Sub-lock

Locking 7-23Unlocking 7-22

Support Plinth 1-37

TTemperature and Humidity 3-1Temperature Rise 3-4Terminal Dimensions 1-4

Heights to Main Facia Items 1-11Severe Environment Fitted 1-9Short Sleeve Before Collar has Been Fitted 1-6Standard Collar 1-7Standard Collar With Advert Light 1-8Standard Sleeve Before Collar has Been Fitted 1-5

Transient Power Loss 2-3Transient Protection A-1

UUnlock 7-5Unlocking

Index-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 261: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Index

Unlocking a Sub-lock 7-22Unlocking and Locking a Security Enclosure with a Controlled Access

Electronic Lock 7-15Unlocking and Locking the Standard Security Enclosure 7-5

VVideo Camera 1-45

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation Index-5

Page 262: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Index

Index-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation

Page 263: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Title:

Number:

NCR welcimprove o

You may

Circle the

Ease of us

Accuracy

Clarity

Complete

Organizat

Appearan

Examples

Illustratio

Job perfor

Question

Overall sa

Indicate th

❑ Impr

❑ Impr

❑ Impr

❑ Impr

❑ Make

❑ Make

Cut

User Feedback Form

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation Manual

ate:

B006-6328-F000

omes your feedback on this publication. Youur information products.

send your comments to us electronically. Se

numbers below that best represent your opi

e 5 4 3 2 1 0

5 4 3 2 1 0

5 4 3 2 1 0

ness 5 4 3 2 1 0

ion 5 4 3 2 1 0

ce 5 4 3 2 1 0

5 4 3 2 1 0

ns 5 4 3 2 1 0

mance 5 4 3 2 1 0

resolution 5 4 3 2 1 0

tisfaction 5 4 3 2 1 0

e ways you feel we could improve this publ

ove the table of contents ❑ A

ove the overview/introduction ❑ A

ove the organization ❑ A

ove the index ❑ A

it less technical ❑ A

it more concise/brief ❑ A

D

r comments can be of great v

e over for details.

nion of this publication.

5 = Excellent4 = Good3 = Adequate2 = Fair1 = Poor

0 = Not applicable

ication.

dd more/better quick refere

dd more examples

dd more illustrations

dd more step-by-step proced

dd more troubleshooting inf

dd more detail

1204

alue in helping us

nce aids

ures

ormation

Page 264: Personas M Series - Money Handling · PDF fileNCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii Federal Communications Commission (FCC) Radio Frequency Interference

Fold

Fold

Cut

AffixPostageStampHere

Write any additional comments you may have below and on additional sheets, if necessary. Include page numbers where applicable.

Use the following addresses to send your comments to us electronically:

e-mail - [email protected]

If we may contact you concerning your comments, please fill in the information below:

Thank you for your evaluation of this publication. Fold the form where indicated, tape (please do not staple),and drop in the mail.

F 8763-0695

Name:

Organization:

Company:

Address:

Phone: Fax:

NCR Financial Solutions Group Ltd.Information Solutions FeedbackKingsway WestDundee ScotlandDD2 3XX