pembekalan ismc vii

23
Explosives and Non Electric Up System Pembekalan ISMC VII Indralaya, 19 – 20 December 2009 Explosives and Non Electric Tie Up System

Upload: muhammad-syafiq-isnaya

Post on 05-Dec-2015

227 views

Category:

Documents


1 download

DESCRIPTION

Pembekalan ISMC VII

TRANSCRIPT

Page 1: Pembekalan ISMC VII

Explosives and Non Electric Up System

Pembekalan ISMC VII

Indralaya, 19 – 20 December 2009

Explosives and Non Electric Tie Up System

Page 2: Pembekalan ISMC VII

Explosives and Non Electric Up System

ExplosivesApa yang dimaksud dengan Explosives?Apa yang membuat explosive meledak? Apakah bahaya bekerja di sekitar Explosive?

Eksplosif adalah campuran bahan kimia yang dapat diubah dengan cepat (detonasi) dari padat ke cair…ke gas bertekanan/bertemperatur tinggi dalam volume besar

Page 3: Pembekalan ISMC VII

Explosives and Non Electric Up System

Segi Tiga ApiOxygenSupply

1 2

H eat /D etonationP ressure

3 4

Page 4: Pembekalan ISMC VII

Explosives and Non Electric Up System

Detonators

Page 5: Pembekalan ISMC VII

Explosives and Non Electric Up System

Types of Exel Detonators

Initiator or starter systemsSurface systemsIn-hole delay systems

Page 6: Pembekalan ISMC VII

Explosives and Non Electric Up System

InitiatorsLead-in Lines

• 150 meters

• 300 meters

• 500 meters

• *2800 meters

Page 7: Pembekalan ISMC VII

Explosives and Non Electric Up System

Lead In Lines150, 300 or 500 m of yellow signal tube (2800* m)

# 8 strength detonator in connector block

Fired by a mushroom starter kit /electronic starter

Can initiate signal tube or Cordtex

Can be used to initiate multiple blasts

Page 8: Pembekalan ISMC VII

Explosives and Non Electric Up System

Application of Lead In Lines

17

1 7

Page 9: Pembekalan ISMC VII

Explosives and Non Electric Up System

Surface SystemConnectadets

Millisecond Connector

Trunkline delay detonators

Cordtex - 3.6g, 5g

Page 10: Pembekalan ISMC VII

Explosives and Non Electric Up System

Exel Connectadet17m

s25

ms42

ms65

ms100

ms150

ms25

4.9

DA

NG

ER

OU

SE

XP

LO

SIV

ES

3.6 - 18m

Page 11: Pembekalan ISMC VII

Explosives and Non Electric Up System

Connectadet Block Capacity

DA

NG

ER

OU

SE

XP

LO

SIV

ES

6-tubes capacity

Page 12: Pembekalan ISMC VII

Explosives and Non Electric Up System

Exel ConnectadetLow strength detonator

Colour coded j-hook,connector block, yellow signal tube

3.6 to 18 m in coil or sleeve

Fires signal tube in both directions

Aligns tube (6 max) at right angles

Need not be buried

Page 13: Pembekalan ISMC VII

Explosives and Non Electric Up System

Boosters

Page 14: Pembekalan ISMC VII

Explosives and Non Electric Up System

BoostersMixture of PETN, TNT, barytes and NaNO3

Cylindrical with cord/detonator well

Sensitised by detonating cord

Initiated by detonating cord and Exel in-hole detonator

Used commonly with bulk explosives

Page 15: Pembekalan ISMC VII

Explosives and Non Electric Up System

TieUp SystemNonel DesignI kon DesignCombination of Nonel & I kon Design

1. V -Cut System2. Center Cut System3. Drop Cut System4. Echelon System5. Combination

Type of TieUp

Page 16: Pembekalan ISMC VII

Explosives and Non Electric Up System

V-Cut System

Page 17: Pembekalan ISMC VII

Explosives and Non Electric Up System

Center Cut System

Page 18: Pembekalan ISMC VII

Explosives and Non Electric Up System

Box Cut System

Page 19: Pembekalan ISMC VII

Explosives and Non Electric Up System

Echelon System

Page 20: Pembekalan ISMC VII

Explosives and Non Electric Up System

Combination System

Page 21: Pembekalan ISMC VII

Explosives and Non Electric Up System

PerhitunganSuatu area blasting dengan luas area 100m x 50m di pertambangan PT. Maju Tak Gentar memiliki karakteristik peledakan sebagai berikut dengan menggunakan jenis bahan peledak Fortis Eclips density 1,25 kg/m : Diameter Lubang Tamrock 311 mm Burden 8 m Spacing 7 m Bench height 16 m Hole depth 17 m Subdrill 1 m Steaming 6 m Buatlah rencana peledakan yang meliputi :Jumlah Explosives (Detonators, Connectadet, arah lemparan)

Page 22: Pembekalan ISMC VII

Explosives and Non Electric Up System

Pf = Jumlah Bahan Peledak = Kg / BCM Batuan Yang terbongkar

1. Lihat Table Blasthole Charge Weight ( D = 311 mm & density = 1,25 kg/m3)2. Tentukan Explosives Length ( Blasthole depth – Stemming length)3. Tentukan Explosives Mass ( 1 x 2)4. Tentukan Blast Volume per hole (Burden x Spacing x Bench Height)5. Tentukan Nilai PF ( 3 / 4)

Page 23: Pembekalan ISMC VII

Explosives and Non Electric Up System