pebbletex adhered mat design - basf
TRANSCRIPT
Pebbletex Adhered Mat DesignTypical Details
(THIS PAGE INTENTIONALLY LEFT BLANK)
1. Pebbletex Adhered Mat Design Application (Plan VIew)
2. Pebbletex Adhered Mat Design (Isometric View)
3. Aesthetic Groove
4. Insulation Boards / Reinforcing Mesh Application at Openings
5. Window Head (Flush)
6. Window Head (Recessed)
7. Window Jamb Detail (Flush)
8. Window Jamb Detail (Recessed)
9. Window Sill Detail (Flush)
10. Window Sill Detail (Recessed)
11. Roof Edge Flashing Detail
12. Metal Coping Detail
13. Parapet Cap Detail
14. Expansion Joint Detail at Floorline
15. Expansion Joint at Change in Substrate
16. Section at Fascia/Soffit
17. Expansion Joint Detail
18. Pipe Penetration
19. Corner Mesh Application with STRONG 15 or HI-IMPACT 20 (Plan View)
20. Corner Mesh Application with Standard Mesh, INTERMEDIATE 6 or 12 (Plan View)
21. Light Fixture
22. Termination at Foundation
23. Termination at Foundation (Flush)
24. Kick-out Flashing Detail
Pebbletex Adhered Mat Design
TABLE OF CONTENTS
0616
Pebbletex® Adhered Mat Design
AM-01 TYPICAL PEBBLETEX ADHERED MAT DESIGN APPLICATION (PLAN VIEW)
AM-02 TYPICAL PEBBLETEX ADHERED MAT DESIGN (ISOMETRIC VIEW)
ACCEPTABLE SHEATHING
PERMALATH 1000 OR METAL LATH
FINESTONE INSULATION BOARD
FRAMING
FINESTONE REINFORCING MESH
FINESTONE BASE COAT
FINESTONE FINISH COAT
MECHANICAL FASTENER
ACCEPTABLE SHEATHING
FINESTONE INSULATION BOARD
FRAMING
FINESTONE BASE COAT
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
PERMALATH 1000 OR METAL LATH
MECHANICAL FASTENER
FINESTONE BASE COAT
SELF-ADHERING MESH TAPE (4”), 4” SHEATHING FABRIC OR BASF WS FLASH
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
FINESTOP®, FINESTOP RA OR SECOND-ARY MOISTURE PROTECTION BARRIER
0616
AM-03 TYPICAL AESTHETIC GROOVE (PLAN VIEW)
AM-04 TYPICAL INSULATION BOARDS/REINFORCING MESH APPLICATION AT OPENINGS
WRAP FINESTONE BASE COAT ANDSTANDARD MESH REINFORCING MESH AT INSULATION BOARD EDGES
FINESTONE INSULATION BOARD
STAGGER INSULATION BOARDJOINTS AT CORNER OF OPENINGS
STANDARD MESH REINFORCING MESH EMBEDDED IN FINESTONE BASE COAT
NOTE: • TYPICAL AT WINDOWS, DOORS, ETC.• MAINTAIN A MIN. 13 mm (1/2”) PERIMETER SEALANT JOINT• FLASHINGS ARE BY OTHERS AND SHALL BE AS PER DESIGN/CODE REQUIREMENTS
229 mm (9”)
305 mm (12”)
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
ACCEPTABLE SHEATHING
FINESTONE INSULATION BOARD
FRAMING
AESTHETIC GROOVE
MIN. 19 mm (3/4”)
PERMALATH 1000 OR METAL LATH
FINESTONE BASE COAT
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
MECHANICAL FASTENER
0616
Pebbletex® Adhered Mat Design
AM-05 TYPICAL WINDOW HEAD (FLUSH)
AM-06 TYPICAL WINDOW HEAD (RECESSED)
ACCEPTABLE SHEATHING
BACKER ROD AND SEALANT
BASF COLOR COAT
FRAMING
WINDOW
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
ACCEPTABLE SHEATHING
SELF-ADHERING MESH TAPE (4”), 4” SHEATHING FABRIC OR BASF WS FLASH
FINESTONE INSULATION BOARD
FRAMING
WINDOW
FLASHING W/ SEALANT
FINESTONE BASE COAT
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
MECHANICAL FASTENER
PERMALATH 1000 OR METAL LATH
NOTE: IF SECONDARY MOISTURE PROTECTION BARRIER IS USED IN LIEU OF FINESTOP OR FINESTOP RA, ENSURE BARRIER IS PROPERLY LAPPED OVER THE FLASHING FLANGE.
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
FINESTONE INSULATION BOARD
FINESTONE BASE COAT
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
MECHANICAL FASTENER
PERMALATH 1000 OR METAL LATH
WRAP BASE COAT AND FINESTONE REINFORCING MESH
0616
AM-07 TYPICAL WINDOW JAMB DETAIL (FLUSH)
AM-08 TYPICAL WINDOW JAMB DETAIL (RECESSED)
ACCEPTABLE SHEATHING
FINESTONE INSULATION BOARD
FINESTONE BASE COAT
BACKER ROD AND SEALANT
BASF COLOR COAT
PERMALATH 1000 OR METAL LATH
SEE ALTERNATE OPTION DETAIL
FINESTOP® FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
FRAMING
MECHANICAL FASTENER
SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA
WINDOW
ACCEPTABLE SHEATHING
FINESTONE INSULATION BOARD
FINESTONE BASE COAT
PERMALATH 1000 OR METAL LATH
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
FRAMING
MECHANICAL FASTENER
SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA
WINDOW
WRAP BASE COAT AND FINESTONE REINFORCING MESH
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
BACKER ROD AND SEALANT
BASF COLOR COAT
BASF WS FLASH
FINESTOP OR FINESTOP RA
ALTERNATE OPENING PROTECTION OPTION FOR WINDOW JAMBS (WS FLASH MAY BE APPLIED UNDER OR OVER THE FINESTOP OR FINESTOP RA).
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
WRAP BASE COAT AND FINESTONE REINFORCING MESHALTERNATE OPENING
PROTECTION OPTION FOR WINDOW JAMBS (WS FLASH MAY BE APPLIED UNDER OR OVER THE FINESTOP OR FINESTOP RA).
WS FLASH
FINESTOP OR FINESTOP RA
0616
Pebbletex® Adhered Mat Design
AM-09 TYPICAL SILL DETAIL (FLUSH)
AM-10 TYPICAL SILL DETAIL (RECESSED)
SEE ALTERNATE OPTION DETAIL
ACCEPTABLE SHEATHING
FINESTONE INSULATION BOARDFINESTONE BASE COAT
BACKER ROD AND SEALANTFINESTONE ASAP
PERMALATH 1000 OR METAL LATH
BASF WS FLASH
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
FINESTOP OR FINESTOP RA
FRAMING
MECHANICAL FASTENER
SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA
WINDOW
WRAP BASE COAT AND FINESTONE REINFORCING MESH
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
ALTERNATE OPENING PROTECTION OPTION FOR WINDOW SILL (WS FLASH MAY BE APPLIED UNDER OR OVER THE FINESTOP OR FINESTOP RA).
SEE ALTERNATE OPTION DETAIL
ACCEPTABLE SHEATHING
FINESTONE INSULATION BOARDFINESTONE BASE COAT
PAN FLASHING
PERMALATH 1000 OR METAL LATH
BASFF WS FLASH
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
FINESTOP OR FINESTOP RA
FRAMING
MECHANICAL FASTENER
SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA
WINDOW
WRAP BASE COAT AND FINESTONE REINFORCING MESH
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
ALTERNATE OPENING PROTECTION OPTION FOR WINDOW SILL (WS FLASH MAY BE APPLIED UNDER OR OVER THE FINESTOP OR FINESTOP RA).
SEALANT
NOTE: • EXTEND FLASHING MIN. 50 mm (2”) OVER EIFS• FLASHINGS ARE BY OTHERS AND SHALL BE AS PER DESIGN/CODE REQUIREMENTS
0616
AM-12 TYPICAL METAL COPING DETAIL
METAL COPING
AM-11 TYPICAL ROOF EDGE FLASHING DETAIL
ACCEPTABLE SHEATHING
FRAMING
FINESTONE INSULATION BOARD
FINESTONE BASE COAT
SEALANT
ROOF SYSTEM
ROOF EDGE FLASHING
WRAP BASE COAT AND FINESTONE REINFORCING MESH
PERMALATH 1000 OR METAL LATH
MIN. 50 mm (2”)
MIN. 50 mm (2”)
ROOF SYSTEM
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
MECHANICAL FASTENER
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
ACCEPTABLE SHEATHING
FINESTONE INSULATION BOARD
FINESTONE BASE COAT
SEALANT
PERMALATH 1000 OR METAL LATH
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
MECHANICAL FASTENER
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
WRAP BASE COAT AND FINESTONE REINFORCING MESH
FRAMING
0616
Pebbletex® Adhered Mat Design
AM-13 TYPICAL PARAPET CAP DETAIL
AM-14 TYPICAL EXPANSION JOINT DETAIL AT FLOORLINE
ACCEPTABLE SHEATHING
FRAMING
FINESTONE INSULATION BOARD
FLOOR SLAB
MIN. 19 mm (3/4”)
MIN. 25 mm (1”)
SEALANT
FINESTONE BASE COAT
BACKER ROD AND SEALANT
ROOF SYSTEM
12
6
MIN. 203 mm
(8” )
PERMALATH 1000 OR METAL LATH
SLIP TRACK
BASF WS FLASH
FLASHING
ACCEPTABLE SHEATHING
FINESTONE INSULATION BOARD
FINESTONE BASE COAT
PERMALATH 1000 OR METAL LATH
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
MECHANICAL FASTENER
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
FRAMING
SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA
WRAP BASE COAT AND FINESTONE REINFORCING MESH
EPS CAP
NOTE: FLASHINGS ARE BY OTHERS AND SHALL BE AS PER DESIGN/CODE REQUIREMENTS
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
WRAP BASE COAT AND FINESTONE REINFORCING MESH
BASF COLOR COAT
WIDTH PER DESIGN
0616
AM-15 TYPICAL EXPANSION JOINT AT CHANGE IN SUBSTRATE
AM-16 TYPICAL SECTION AT FASCIA/SOFFIT
ACCEPTABLE SHEATHING
FRAMING
FINESTONE INSULATION BOARD
ACCEPTABLE SHEATHING
FINESTONE INSULATION BOARD
BACKER ROD AND SEALANT
BASF COLOR COAT
NOTE: JOINT WIDTH PER DESIGN
PEBBLETEX CLASSIC PB SYSTEM
PERMALATH 1000 OR METAL LATH
FINESTONE BASE COAT
PERMALATH 1000 OR METAL LATH
FINESTONE BASE COAT
BASF WS FLASH
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
WRAP BASE COAT AND FINESTONE REINFORCING MESH
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
ACCEPTABLE SUBSTRATE
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
WRAP BASE COAT AND FINESTONE REINFORCING MESH
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
NOTE: EXTEND FINESTOP OR FINESTOP RA A MIN. OF 102 MM (4”) ONTO SOFFIT. USE APPROPRIATE REINFORCEMENT AT CORNER.
0616
Pebbletex® Adhered Mat Design
AM-17 TYPICAL EXPANSION JOINT DETAIL
AM-18 TYPICAL PIPE PENETRATION
ACCEPTABLE SHEATHING
FRAMING
FINESTONE INSULATION BOARD
SEALANT AT PERIMETER OF PENETRATION
BACKER ROD AND SEALANT
BASF COLOR COAT
MIN. 13 mm (1/2”)
ACCEPTABLE SHEATHING
FRAMING
FINESTONE INSULATION BOARD
BASF WS FLASH
FINESTONE BASE COAT
BACKER ROD AND SEALANTWIDTH PER DESIGN
PERMALATH 1000 OR METAL LATH
BASF COLOR COAT
FINESTONE BASE COAT
PERMALATH 1000 OR METAL LATH
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING • MESH• FINESTONE FINISH COAT
WRAP BASE COAT AND FINESTONE REINFORCING MESH
FINESTOP®, FINESTOP RA OR SEC-ONDARY MOISTURE PROTECTION BARRIER
WRAP BASE COAT AND FINESTONE REINFORCING MESH
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING • MESH• FINESTONE FINISH COAT
0616
AM-19 TYPICAL CORNER MESH APPLICATION WITH STRONG 15 OR HI-IMPACT 20 (PLAN VIEW)
AM-20 TYPICAL CORNER MESH APPLICATION WITH STANDARD MESH, INTERMEDIATE 6 OR 12 (PLAN VIEW)
ACCEPTABLE SHEATHINGFRAMING
FINESTONE BASE COAT
CORNER MESH EMBEDDED IN BASE COAT
STANDARD MESH REINFORCING MESH OR INTERMEDIATE 6 EMBEDDED IN FINESTONE BASE COAT
STRONG 15 OR HI-IMPACT 20 EMBEDDED IN FINESTONE BASE COAT
FINESTONE INSULATION BOARDPERMALATH 1000 OR METAL LATH
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA
NOTE: • BUTT EDGE OF STRONG 15 OR HI-IMPACT 20 TO CORNER MESH• A CONTINUOUS OVERLAY OF STANDARD MESH OR INTERMEDIATE 6 IS REQUIRED OVER STRONG 15, HI-IMPACT 20 OR CORNER MESH.
ACCEPTABLE SHEATHINGFRAMING
FINESTONE BASE COAT
CORNER MESH EMBEDDED IN BASE COAT
STANDARD MESH REINFORCING MESH OR INTERMEDIATE 6 EMBEDDED IN FINESTONE BASE COAT
FINESTONE INSULATION BOARD
PERMALATH 1000 OR METAL LATH
FINESTOP®, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
SELF-ADHERING MESH TAPE (9”) EMBEDDED IN FINESTOP OR 9” SHEATHING FABRIC EMBEDDED IN FINESTOP RA
NOTE: A CONTINUOUS OVERLAY OF STANDARD MESH OR INTERMEDIATE 6 OR 12 IS REQUIRED OVER CORNER MESH.
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING • MESH• FINESTONE FINISH COAT
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
0616
Pebbletex® Adhered Mat Design
AM-21 TYPICAL LIGHT FIXTURE
AM-22 TYPICAL TERMINATION AT FOUNDATION
ACCEPTABLE SHEATHING
FRAMING
FOUNDATION
FLASHING
FINESTONE BASE COAT
ACCEPTABLE SHEATHING
PERMALATH 1000 OR METAL LATH
FRAMING
WIRE OPENING
FINESTONE BASE COAT
SET FLANGE IN SEALANT
SMALL LIGHT FIXTURE
FINESTONE INSULATION BOARD
FINESTONE INSULATION BOARD
SEALANT
PERMALATH 1000 OR METAL LATH
FINESTOPTM, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
WRAP BASE COAT AND FINESTONE REINFORCING MESH
FINESTOPTM, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
SELF-ADHERING MESH TAPE (4”), 4” SHEATHING FABRIC OR BASF WS FLASH
WRAP BASE COAT AND FINESTONE REINFORCING MESH
NOTE: • IF SECONDARY MOISTURE PROTECTION BARRIER IS
USED IN LIEU OF FINESTOP OR FINESTOP RA, ENSURE BARRIER IS PROPERLY LAPPED OVER THE FLASHING FLANGE.
• TERMINATE PEBBLETEX ADHERED MAT DESIGN SYSTEM MIN. 203 mm (8”) ABOVE GRADE.
MIN. 50 mm (2”)MAX. 305 mm (12”)
0616
AM-23 TYPICAL TERMINATION AT FOUNDATION (FLUSH)
ACCEPTABLE SHEATHING
FRAMING
FOUNDATION
FINESTONE INSULATION BOARD
PERMALATH 1000 OR METAL LATH
BACKER ROD, SEALANTAND WEEP TUBE
BASF COLOR COATMIN. 25 mm (1”)
FINESTONE BASE COAT
BASF WS FLASH
AM-24 TYPICAL KICK-OUT FLASHING DETAIL
ACCEPTABLE SHEATHING
PEBBLETEX ADHERED MAT DESIGN
STEP FLASHING
BACKER ROD AND SEALANT
ROOF SHINGLES
BUILDING PAPER
DRIP EDGE
KICK-OUT FLASHING
MIN. 100 mm (4”)
MIN. 50 mm (2”)
FINESTOPTM, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
WRAP BASE COAT AND FINESTONE REINFORCING MESH
FINESTOPTM, FINESTOP RA OR SECONDARY MOISTURE PROTECTION BARRIER
FINESTONE LAMINA:• FINESTONE BASE COAT• FINESTONE REINFORCING MESH• FINESTONE FINISH COAT
NOTE: • KICK-OUT FLASHING MUST BE ANGLED 100˚ MIN.TO ALLOW FOR PROPER DRAINAGE.• KICK-OUT FLASHING SEAMS MUST BE SOLDERED OR SEALED WITH APPROPRIATE SEALANT.• TERMINATE PEBBLETEX ADHERED MAT DESIGN MIN. 50 mm (2”) ABOVE ROOF.
BASF Corporation - Wall Systems | 3550 St Johns Bluff Rd South Jacksonville, Florida 32224 P: 800.221.9255 F: 904.996.6300 www.finestone.basf.com© 2016 BASF Corporation rev 160622
For the most current version of this literature, please visit our website at www.finestone.basf.com.
Pebbletex® Adhered Mat Design