pdo2 precision dissolved oxygen measurement pdo2.pdfbarben analyzer technology is proudly produces...
TRANSCRIPT
Barben Analyzer Technology is proudly produces the PDO2 optical dissolved oxygen sensor to provide you the unequalled performance by any other dissolved oxygen sensor. Designed for simplicity, but made for durability to match your demanding require-ments while also providing you the flexibility to meet your application needs.
Perfect to use in the following area’s: - Wastewater Treatment Facilities - Water Treatment Facilities - Petrochemical/Chemical Plants - Aquatic Tanks or Pools - Paper & Pulp Industry - Inline Measurement - Water Monitoring - Fish Hatcheries
� No Membranes to Replace � No Consumables � No Electrolyte to Replace � No Flow Necessary � Polypropylene Body � Not Damaged by Sunlight � Electronics Completely Sealed � Fast, Dependable Readings � Multiple Measurement � Optical Isolation provides Optimum Performance in Sunlight
Reduce your Maintenance and Increase your Reliability!
PDO2 Precision Dissolved Oxygen Measurement
For Municipal and Industrial Waste Water Treatment Fluorescent Dissolved Oxygen Monitoring System Designed for use in the Harshest Environments
Process Control Services Pty Ltd, ABN 22 054 111 018 Ph: Brisbane (07) 3299 7881, Melbourne (03) 9859 0157, Sydney (02) 9319 1808, Auckland (09) 525 3425
eMail [email protected], Web www.pcspl.com.au
How Dynamic Quenching of Luminescence Works The principle of measurement is based on the effect of dynamic luminescence quenching by molecular oxygen. The following scheme explains the principle of dynamic luminescence quenching by oxygen.
Principle of dynamic quenching of luminescence by molecular oxygen (1) Luminescence process in absence of oxygen (2) Deactivation of the luminescent indicator molecule by molecular oxygen
The collision between the luminophore in its excited state and the quencher (oxygen) results in radiation-less deactivation and is called collisional or dynamic quenching. After collision, energy transfer takes place from the excited indicator molecule to oxygen which consequently is transferred from its ground state (triplet state) to its excited singlet state. As a result, the indicator molecule does not emit lumines-cence and the measurable luminescence signal decreases. A relation exists between the oxygen con-centration in the sample and the luminescence intensity as well as the luminescence lifetime.
Process Control Services Pty Ltd, ABN 22 054 111 018 Ph: Brisbane (07) 3299 7881, Melbourne (03) 9859 0157, Sydney (02) 9319 1808, Auckland (09) 525 3425
eMail [email protected], Web www.pcspl.com.au
Specifications:
1401-M Transmitter
Main Power 110/ 230 Vac; 50/60 Hz Main Power 24 Vdc (50 mA)
Power Consumption 11 VA Power Consumption 0.6 W (Nom) 1W (Startup)
Display 120 x 32 Pixels Measuring Range 0.05 - 20.00 mg/l
Back light Programmable Operating Range -10 to 70 C
Measurement Range 0 - 10 mg/l (Adjustable) Response Time t90 <30s (Air to Nitrogen)
Inputs (2) Sensor/Temperature Accuracy +/- 2% @ 25C
Outputs 4 - 20 mA/Relay x 2 Detection Limit 0.05 mg/l
Operating Range -15 to 65C Pressure Range 170 PSI/12 Bar
Excitation 24 Vdc (50 mA) Detection Method Fluorescent Quenching
Rating NEMA 4X (IP-65) Body Material Polypropylene or Kynar
PDO2 Sensor
PDO2 Dissolved Oxygen Probe Options and Accessories
Process Control Services Pty Ltd, ABN 22 054 111 018 Ph: Brisbane (07) 3299 7881, Melbourne (03) 9859 0157, Sydney (02) 9319 1808, Auckland (09) 525 3425
eMail [email protected], Web www.pcspl.com.au
Cleaning Nozzle
Probe Held in Position by 40mm (1.1/2”) Pipe
Bracket for Rail Mounting
Slip on Cap for Easy removal and insertion of probe
PVC Weather Shield, Rail Mount Stand and Air Blast Cleaning Kit
(3 Bar Air Supply)
Automatic Cleaning System & Mounting Accessories
Maintains a clean sensor surface to eliminate the need for routine cleaning. Uses 3 to 5 Bar Air Supply. Air blast frequency configurable in electronics. Solenoid operate by relay in electronics unit. System includes small receiver to ensure full impact of blast is not affected by long lengths of air line.
Air Blast Line Follows probe cable
ARC Wireless Handheld Communicator and Calibrator
� Collect data on sensor history, quality and performance.
� Easy in field calibration or configuration.
� Generate system configuration reports.
� Generate performance reports.
� Simplify service and QA functions.
ECH
NO
LOG
YT
NA
LYZE
RAARB
ENB
UN
LES
S O
THE
RW
ISE
SP
EC
IFIE
DO
PTI
CA
L D
O S
EN
SOR
2P01
47
PH
(775
)882
-790
0 FA
X(77
5)88
3-63
88
TOLE
RA
NC
ES
RE
VIS
ION
SR
EV
DA
TED
ES
CR
IPTI
ON
DW
NA
PV
D
.0 +
/- .1
5
.00
+/- .
010
.000
+/-
.005
.000
0 +/
- .00
05
+/- 3
0MIN
ANG
LES
+/- .
015
FRA
CTI
ON
SD
EC
IMA
LS
DIM
ENS
ION
S IN
INC
HES
D09
/21/
09N
ON
E
DR
AW
ING
BY
RW
SIZ
ES
CA
LED
ATE
1 O
F 1
AP
PR
OV
ED
CH
EC
KE
D
DR
AW
ING
NO
.
H.W
.M.
H.W
.M.
8.9"
RE
PLA
CE
AB
LE O
PTI
CA
L N
OS
E
PO
LYPR
OP
YLE
NE
OR
KYN
AR W
ITH
EP
DM
OR
VIT
ON
SE
ALS
.865
O
1-1/
2"3/
4" N
PT
THR
EAD
PO
LYPR
OP
YLE
NE
OR
KYN
AR B
OD
Y E
PD
M O
R V
ITO
N IN
TER
NA
L S
EA
LSN
YLO
N C
OR
D G
RIP
3/4"
NP
T TH
REA
D
30 F
T. C
AB
LE
STA
ND
AR
D /
CU
STO
M
LEN
GTH
S A
VA
ILA
BLE
SIL
ICO
NE
PR
OTE
CTE
D L
UM
INO
PH
OR
E(D
O N
OT
TOU
CH
OR
SC
RA
TCH
SU
RFA
CE
)
ADJU
STA
BLE
CO
RD
GR
IP A
SS
EM
BLY
PV
C
4-1/
4"V
P8
MA
LE C
ON
NE
CTO
R
4"
1-1/
2" N
PT
THR
EAD
1.05
O
RA
TIN
GS
-10
TO 8
0 C
PO
LYPR
O
-15
TO 1
00 P
SIG
K
YNAR
-1
5 TO
150
PS
IG
PO
LYU
RE
THA
NE
CA
BLE
FIN
GE
R T
IGH
TEN
TH
RE
AD
SO
NLY
SLI
P F
OR
C
US
TOM
ERS
1-1/
2" S
TAN
D P
IPE
1/4"
HO
LE (T
YP
)1.
5FT
SP
AC
ING
ALO
NG
PIP
E L
EN
GTH
DR
AW
ING
NO
.
CH
ECK
ED
AP
PR
OV
ED
1 O
F 1
DA
TES
CA
LES
IZE
DR
AW
ING
BY
. MW
NO
NE
10/2
3/09
B
DIM
EN
SIO
NS
IN IN
CH
ES
DE
CIM
ALS
FRA
CTI
ON
S
+/- .
015
AN
GLE
S
+/- 3
0MIN
.000
0 +/
- .00
05
.000
+/-
.005
.00
+/- .
010
.0 +
/- .1
5
AP
VD
DW
ND
ES
CR
IPTI
ON
DAT
ER
EV
RE
VIS
ION
STO
LER
AN
CE
S
2P01
50
B51
03-2
001
SE
NS
OR
W/T
INN
ED L
EA
DS
CU
STO
ME
R C
ON
NEC
TIO
N T
O P
LCU
NLE
SS
OTH
ER
WIS
E S
PE
CIF
IED
1-1/
2" P
VC
PIP
E(C
US
TOM
ER S
UP
PLI
ED
)
LE
AD
DE
SC
.S
HIE
LD+7
TO
30V
DC
(100
0MW
MA
X)P
.S. G
RD
A
1"
CO
RD
GR
IP A
SS
EM
BLY
B51
10-1
004
(INC
LUD
ED
WIT
H S
EN
SO
R)
BR
AC
KE
T1-
1/2"
PIP
E M
TB
5008
-001
8
CU
STO
MER
'SH
AN
D R
AIL
APP
RO
X.45
°A
PPR
OX.
45°
SE
T S
CR
EWS
(2 T
YP
)
SE
T S
CR
EW
S(2
TY
P)
DE
TAIL
A
GR
EE
N /
YE
LLO
W B
5103
-200
1 S
EN
SO
R
RE
D C
OA
X C
OR
ER
ED
CO
AX S
HIE
LD
SE
NS
OR
CA
BLE
AN
OD
EB
LAC
K C
OAX
SH
IELD
PLC
(SU
PPLI
ED
BY
OTH
ER
S)
+ - GN
D
+24V
DC
-24V
DC
+ -IN
PU
T
4-20
MA
INP
UT
MO
DU
LE(S
UP
PLI
ED
BY
OTH
ER
S)
BLA
CK
CO
AX
SH
IELD
(INP
UT)
RE
D C
OAX
SH
IELD
(P.S
. GN
D)
GR
N/Y
ELL
OW
(SH
IELD
)
RE
D C
OAX
CO
RE
+7 T
O 3
0 V
DC
PH
(775
)883
-250
0 F
AX(
775)
297-
4740
5200
Con
vair
Driv
eC
arso
n C
ity, N
V 8
9706
C
0
3/30
/11
AD
D P
/N D
ETA
ILS
WC
H
WM