pdo2 precision dissolved oxygen measurement pdo2.pdfbarben analyzer technology is proudly produces...

5
Barben Analyzer Technology is proudly produces the PDO2 optical dissolved oxygen sensor to provide you the unequalled performance by any other dissolved oxygen sensor. Designed for simplicity, but made for durability to match your demanding require- ments while also providing you the flexibility to meet your application needs. Perfect to use in the following area’s: - Wastewater Treatment Facilities - Water Treatment Facilities - Petrochemical/Chemical Plants - Aquatic Tanks or Pools - Paper & Pulp Industry - Inline Measurement - Water Monitoring - Fish Hatcheries No Membranes to Replace No Consumables No Electrolyte to Replace No Flow Necessary Polypropylene Body Not Damaged by Sunlight Electronics Completely Sealed Fast, Dependable Readings Multiple Measurement Optical Isolation provides Optimum Performance in Sunlight Reduce your Maintenance and Increase your Reliability! PDO2 Precision Dissolved Oxygen Measurement For Municipal and Industrial Waste Water Treatment Fluorescent Dissolved Oxygen Monitoring System Designed for use in the Harshest Environments Process Control Services Pty Ltd, ABN 22 054 111 018 Ph: Brisbane (07) 3299 7881, Melbourne (03) 9859 0157, Sydney (02) 9319 1808, Auckland (09) 525 3425 eMail [email protected], Web www.pcspl.com.au

Upload: others

Post on 03-Sep-2020

14 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PDO2 Precision Dissolved Oxygen Measurement PDO2.pdfBarben Analyzer Technology is proudly produces the PDO2 optical dissolved oxygen sensor to provide you the unequalled performance

Barben Analyzer Technology is proudly produces the PDO2 optical dissolved oxygen sensor to provide you the unequalled performance by any other dissolved oxygen sensor. Designed for simplicity, but made for durability to match your demanding require-ments while also providing you the flexibility to meet your application needs.

Perfect to use in the following area’s: - Wastewater Treatment Facilities - Water Treatment Facilities - Petrochemical/Chemical Plants - Aquatic Tanks or Pools - Paper & Pulp Industry - Inline Measurement - Water Monitoring - Fish Hatcheries

� No Membranes to Replace � No Consumables � No Electrolyte to Replace � No Flow Necessary � Polypropylene Body � Not Damaged by Sunlight � Electronics Completely Sealed � Fast, Dependable Readings � Multiple Measurement � Optical Isolation provides Optimum Performance in Sunlight

Reduce your Maintenance and Increase your Reliability!

PDO2 Precision Dissolved Oxygen Measurement

For Municipal and Industrial Waste Water Treatment Fluorescent Dissolved Oxygen Monitoring System Designed for use in the Harshest Environments

Process Control Services Pty Ltd, ABN 22 054 111 018 Ph: Brisbane (07) 3299 7881, Melbourne (03) 9859 0157, Sydney (02) 9319 1808, Auckland (09) 525 3425

eMail [email protected], Web www.pcspl.com.au

Page 2: PDO2 Precision Dissolved Oxygen Measurement PDO2.pdfBarben Analyzer Technology is proudly produces the PDO2 optical dissolved oxygen sensor to provide you the unequalled performance

How Dynamic Quenching of Luminescence Works The principle of measurement is based on the effect of dynamic luminescence quenching by molecular oxygen. The following scheme explains the principle of dynamic luminescence quenching by oxygen.

Principle of dynamic quenching of luminescence by molecular oxygen (1) Luminescence process in absence of oxygen (2) Deactivation of the luminescent indicator molecule by molecular oxygen

The collision between the luminophore in its excited state and the quencher (oxygen) results in radiation-less deactivation and is called collisional or dynamic quenching. After collision, energy transfer takes place from the excited indicator molecule to oxygen which consequently is transferred from its ground state (triplet state) to its excited singlet state. As a result, the indicator molecule does not emit lumines-cence and the measurable luminescence signal decreases. A relation exists between the oxygen con-centration in the sample and the luminescence intensity as well as the luminescence lifetime.

Process Control Services Pty Ltd, ABN 22 054 111 018 Ph: Brisbane (07) 3299 7881, Melbourne (03) 9859 0157, Sydney (02) 9319 1808, Auckland (09) 525 3425

eMail [email protected], Web www.pcspl.com.au

Specifications:

1401-M Transmitter

Main Power 110/ 230 Vac; 50/60 Hz Main Power 24 Vdc (50 mA)

Power Consumption 11 VA Power Consumption 0.6 W (Nom) 1W (Startup)

Display 120 x 32 Pixels Measuring Range 0.05 - 20.00 mg/l

Back light Programmable Operating Range -10 to 70 C

Measurement Range 0 - 10 mg/l (Adjustable) Response Time t90 <30s (Air to Nitrogen)

Inputs (2) Sensor/Temperature Accuracy +/- 2% @ 25C

Outputs 4 - 20 mA/Relay x 2 Detection Limit 0.05 mg/l

Operating Range -15 to 65C Pressure Range 170 PSI/12 Bar

Excitation 24 Vdc (50 mA) Detection Method Fluorescent Quenching

Rating NEMA 4X (IP-65) Body Material Polypropylene or Kynar

PDO2 Sensor

Page 3: PDO2 Precision Dissolved Oxygen Measurement PDO2.pdfBarben Analyzer Technology is proudly produces the PDO2 optical dissolved oxygen sensor to provide you the unequalled performance

PDO2 Dissolved Oxygen Probe Options and Accessories

Process Control Services Pty Ltd, ABN 22 054 111 018 Ph: Brisbane (07) 3299 7881, Melbourne (03) 9859 0157, Sydney (02) 9319 1808, Auckland (09) 525 3425

eMail [email protected], Web www.pcspl.com.au

Cleaning Nozzle

Probe Held in Position by 40mm (1.1/2”) Pipe

Bracket for Rail Mounting

Slip on Cap for Easy removal and insertion of probe

PVC Weather Shield, Rail Mount Stand and Air Blast Cleaning Kit

(3 Bar Air Supply)

Automatic Cleaning System & Mounting Accessories

Maintains a clean sensor surface to eliminate the need for routine cleaning. Uses 3 to 5 Bar Air Supply. Air blast frequency configurable in electronics. Solenoid operate by relay in electronics unit. System includes small receiver to ensure full impact of blast is not affected by long lengths of air line.

Air Blast Line Follows probe cable

ARC Wireless Handheld Communicator and Calibrator

� Collect data on sensor history, quality and performance.

� Easy in field calibration or configuration.

� Generate system configuration reports.

� Generate performance reports.

� Simplify service and QA functions.

Page 4: PDO2 Precision Dissolved Oxygen Measurement PDO2.pdfBarben Analyzer Technology is proudly produces the PDO2 optical dissolved oxygen sensor to provide you the unequalled performance

ECH

NO

LOG

YT

NA

LYZE

RAARB

ENB

UN

LES

S O

THE

RW

ISE

SP

EC

IFIE

DO

PTI

CA

L D

O S

EN

SOR

2P01

47

PH

(775

)882

-790

0 FA

X(77

5)88

3-63

88

TOLE

RA

NC

ES

RE

VIS

ION

SR

EV

DA

TED

ES

CR

IPTI

ON

DW

NA

PV

D

.0 +

/- .1

5

.00

+/- .

010

.000

+/-

.005

.000

0 +/

- .00

05

+/- 3

0MIN

ANG

LES

+/- .

015

FRA

CTI

ON

SD

EC

IMA

LS

DIM

ENS

ION

S IN

INC

HES

D09

/21/

09N

ON

E

DR

AW

ING

BY

RW

SIZ

ES

CA

LED

ATE

1 O

F 1

AP

PR

OV

ED

CH

EC

KE

D

DR

AW

ING

NO

.

H.W

.M.

H.W

.M.

8.9"

RE

PLA

CE

AB

LE O

PTI

CA

L N

OS

E

PO

LYPR

OP

YLE

NE

OR

KYN

AR W

ITH

EP

DM

OR

VIT

ON

SE

ALS

.865

O

1-1/

2"3/

4" N

PT

THR

EAD

PO

LYPR

OP

YLE

NE

OR

KYN

AR B

OD

Y E

PD

M O

R V

ITO

N IN

TER

NA

L S

EA

LSN

YLO

N C

OR

D G

RIP

3/4"

NP

T TH

REA

D

30 F

T. C

AB

LE

STA

ND

AR

D /

CU

STO

M

LEN

GTH

S A

VA

ILA

BLE

SIL

ICO

NE

PR

OTE

CTE

D L

UM

INO

PH

OR

E(D

O N

OT

TOU

CH

OR

SC

RA

TCH

SU

RFA

CE

)

ADJU

STA

BLE

CO

RD

GR

IP A

SS

EM

BLY

PV

C

4-1/

4"V

P8

MA

LE C

ON

NE

CTO

R

4"

1-1/

2" N

PT

THR

EAD

1.05

O

RA

TIN

GS

-10

TO 8

0 C

PO

LYPR

O

-15

TO 1

00 P

SIG

K

YNAR

-1

5 TO

150

PS

IG

PO

LYU

RE

THA

NE

CA

BLE

FIN

GE

R T

IGH

TEN

TH

RE

AD

SO

NLY

SLI

P F

OR

C

US

TOM

ERS

1-1/

2" S

TAN

D P

IPE

Page 5: PDO2 Precision Dissolved Oxygen Measurement PDO2.pdfBarben Analyzer Technology is proudly produces the PDO2 optical dissolved oxygen sensor to provide you the unequalled performance

1/4"

HO

LE (T

YP

)1.

5FT

SP

AC

ING

ALO

NG

PIP

E L

EN

GTH

DR

AW

ING

NO

.

CH

ECK

ED

AP

PR

OV

ED

1 O

F 1

DA

TES

CA

LES

IZE

DR

AW

ING

BY

. MW

NO

NE

10/2

3/09

B

DIM

EN

SIO

NS

IN IN

CH

ES

DE

CIM

ALS

FRA

CTI

ON

S

+/- .

015

AN

GLE

S

+/- 3

0MIN

.000

0 +/

- .00

05

.000

+/-

.005

.00

+/- .

010

.0 +

/- .1

5

AP

VD

DW

ND

ES

CR

IPTI

ON

DAT

ER

EV

RE

VIS

ION

STO

LER

AN

CE

S

2P01

50

B51

03-2

001

SE

NS

OR

W/T

INN

ED L

EA

DS

CU

STO

ME

R C

ON

NEC

TIO

N T

O P

LCU

NLE

SS

OTH

ER

WIS

E S

PE

CIF

IED

1-1/

2" P

VC

PIP

E(C

US

TOM

ER S

UP

PLI

ED

)

LE

AD

DE

SC

.S

HIE

LD+7

TO

30V

DC

(100

0MW

MA

X)P

.S. G

RD

A

1"

CO

RD

GR

IP A

SS

EM

BLY

B51

10-1

004

(INC

LUD

ED

WIT

H S

EN

SO

R)

BR

AC

KE

T1-

1/2"

PIP

E M

TB

5008

-001

8

CU

STO

MER

'SH

AN

D R

AIL

APP

RO

X.45

°A

PPR

OX.

45°

SE

T S

CR

EWS

(2 T

YP

)

SE

T S

CR

EW

S(2

TY

P)

DE

TAIL

A

GR

EE

N /

YE

LLO

W B

5103

-200

1 S

EN

SO

R

RE

D C

OA

X C

OR

ER

ED

CO

AX S

HIE

LD

SE

NS

OR

CA

BLE

AN

OD

EB

LAC

K C

OAX

SH

IELD

PLC

(SU

PPLI

ED

BY

OTH

ER

S)

+ - GN

D

+24V

DC

-24V

DC

+ -IN

PU

T

4-20

MA

INP

UT

MO

DU

LE(S

UP

PLI

ED

BY

OTH

ER

S)

BLA

CK

CO

AX

SH

IELD

(INP

UT)

RE

D C

OAX

SH

IELD

(P.S

. GN

D)

GR

N/Y

ELL

OW

(SH

IELD

)

RE

D C

OAX

CO

RE

+7 T

O 3

0 V

DC

PH

(775

)883

-250

0 F

AX(

775)

297-

4740

5200

Con

vair

Driv

eC

arso

n C

ity, N

V 8

9706

C

0

3/30

/11

AD

D P

/N D

ETA

ILS

WC

H

WM